Loading...
HomeMy WebLinkAboutPermit PG16-0161 - ANGUIANO RESIDENCE - GAS PIPING TO FURNACEANGUIANO RESIDENCE 14070 MILITARY RD S EXPIRED 06/13/17 PG1 6=01 61 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 5537200043 Permit Number: PG16-0161 Address: 14070 MILITARY RD S Issue Date: 10/27/2016 Permit Expires On: 4/25/2017 Project Name: ANGUTANO RESIDENCE Owner: Name: ANGUTANO JUAN MANUEL Address: 14070 MILITARY RD S, TUKWILA, WA, Lender: Name: Address: DESCRIPTION OF WORK: GAS PIPE FROM METER TO FURNACE Phone: (206) 243-7700 Phone: (206) 243-7700 Expiration Date: 11/2/2017 Valuation of Work: $100.00 Fees Collected: $102.38 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 98168 Contact Person: 2014 Name: RANDY HOEFER Address: 12462 DES MOINES MEMORIAL DR, International Mechanical Code Edition: BURIEN, WA, 98168 Contractor: 2014 Name: GLENDALE HEATING & A/C INC Address: 12462 DES MOINES MEMORIAL DR, International Fuel Gas Code: SEATTLE, WA, 98168-2266 License No: GLENDHA053Q2 Lender: Name: Address: DESCRIPTION OF WORK: GAS PIPE FROM METER TO FURNACE Phone: (206) 243-7700 Phone: (206) 243-7700 Expiration Date: 11/2/2017 Valuation of Work: $100.00 Fees Collected: $102.38 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Ulm ed l ' M) 0 % Date: O I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached Ato,�this permit. Signature: �i �'� L'✓a C Date: /D 71 j , Print Name: 4 LA.L 1 -A r1`10 A/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKWL . • Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use onl PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print* SITE LOCATION King Co Assessor's Tax No.: 553720-0043 Site Address: 14070 Military Rd Suite Number: Floor: Tenant Name: New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: Juan Anguiano Address: 14070 Military Rd S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Randy Hoefer Address: 12462 Des Moines Memorial Dr City: Burien State: WA Zip: 98168 Phone: (206) 243-7700 Fax: (206) 243-8344 Email: &nom I @ 1 _ o . Um u Valuation of Project (contractor's bid price): $ I D Q • Go PLUMBING CONTRACTOR INFORMATION Company Name: Glendale Heating & Air Conditioning Address: 12462 Des Moines Memorial Dr City: Burien State: WA Zip: 98168 Phone: (206) 243-4400 Fax: (206) 243-8344 Contr Reg No.: GLENDHA053Q Exp Date: 11 1 W 1 -7 Tukwila Business License No.: —6LkS— 09939-1 1 Scope of Work (please provide detailed information): C -16S pi PC T -Y -Dm M Cfe r 40 �i,�,r VT C -g- Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line\2011 ApplicationsTiumbing Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity uelow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler(per head Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Print Name: Mailing Date: Telephone: (2V tP 2r-7-7 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.doex Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $102.38 PG16-0161 Address: 14070 MILITARY RD S Apn: 5537200043 $102.38 GAS $97.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .. 752 R000.322.900.04.00 0.00 $4.88 $102.38 Date Paid: Thursday, October 27, 2016 Paid By: GLENDALE HEATING & A/C INC Pay Method: CHECK 008651 Printed: Thursday, October 27, 2016 11:28 AM 1 of 1 E��' 1�SYS7EM5 INSPECTION RECORD Retain a copy with pe, t lf&16_0161 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro, ctpp: /�rlr(i ® a l bC Type of Inspection: �rA Address: A1020 !LI Date Called: Special Instructions: Date Wante a / 2 %S %G P. . Requester. Phone No: IInspector: I�AAA IDate: i 7/1( ll� I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 5/1/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director RANDY HOEFER 12462 DES MOINES MEMORIAL DR BURIEN, WA 98168 RE: Permit No. PG 16-0161 ANGUTANO RESIDENCE 14070 MILITARY RD S Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/13/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/13/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PG 16-0161 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 GLENDALE HEATING & A/C I'NT" //erne Espdiol Contact Safety & Health Claims & Insurance 40 Washington State Department of Labor & Industries GLENDALE HEATING & A/C INC Owner or tradesperson Principals HOEFER, GERALD ARTHUR, PRESIDENT FULTON, DAVID CURTIS, SECRETARY ATWOOD, STANLEY, AGENT (End: 06/26/2012) HOEFER, ARTHUR A, TREASURER (End: 09/30/2011) Doing business as GLENDALE HEATING & A/C INC 12462 DES MOINES MEMORIAL DR SEATTLE, WA 98168-2266 206-243-7700 KING County Page 1 of 2 Search L&I A -'L :Index Help My IRI Workplace Rights Trades & Licensing WA UBI No. Business type 600 003 167 Corporation Governing persons DAVID C FULTON GERALD A HOEFER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor ........................................................................ Active. Meets current requirements. License specialties GENERAL License no. GLENDHA053Q2 Effective — expiration 11/22/1995— 11/02/2017 Bond No bond accounts during the previous 6 year period. Insurance .......... _.......... _.... . HDI -Gerling America Insurance $2,000,000.00 Policy no. EGGCD000173416 Received by L&I Effective date 09/23/2016 11/02/2016 Expiration date 11/02/2017 Continental Western Ins Co $1,000,000.00 Policy no. CDP2976203 Help us improve https:Hsecure.lnima.gov/verify/Detail.aspx?UBI=600003167&LIC=GLENDHA053Q2&SAW= 10/27/2016