Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG16-0030 - BOEING EMPLOYEES CREDIT UNION (BECU) - RESTROOMS, DRINKING FOUNTAIN, SINKS ETC
BECU 13035 GATEWAY DR PG16-0030 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT Parcel No: 0004800015 Permit Number: PG16-0030 Address: 13035 GATEWAY DR BLDG 9 Issue Date: 4/28/2016 Permit Expires On: 10/25/2016 Project Name: BECU Owner: 2012 Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900, SCOTTSDALE, WA, WA Cities Electrical Code: 85261 Contact Person: 2012 Name: TERESE ANDERSON Address: 1221 SECOND AVE N, KENT, WA, WA State Energy Code: 98032 Contractor: 2012 Name: HERMANSON COMPANY LLP Address: 1221 2ND AVE N, KENT, WA, 98032- 2945 License No: HERMACLO05BJ Lender: Name: Address: ''I DESCRIPTION OF WORK: Phone: (253) 796-5825 Phone: (206) 575-9700 Expiration Date: 8/25/2016 DEMO: WATER CLOSETS TO WALL, LAVATORIES, URINALS, DRINKING FOUNTAIN, SINKS. INSTALL: WATER CLOSETS, LAVATORIES, URINALS, DRINKING FOUNTAIN BREAK SINK, GARBAGE DISPOSAL. PROVIDE AND INSTALL 2 FLOOR DRAINS AT RESTROOMS, INCLUDES WASTE CONNECTION ATAPPROX 10', INSTALL WATER FILTER SYSTEM, INSTALL SINK DW WASTE CONNECTION AND WATER SUPPLY OFF OF EXISTING ANGLE STOP AND WASTE. INSTALL UNDER SINK ICEMAKER WATER CONNECTION OFF OF EXISTING ANGLE STOP Valuation of Work: $18,900.00 Fees Collected: $363.36 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: G v I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print turesi�U�i Date: Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.p,ov Plumbing/Gas Permit No. 100 Project No. Date Application Accepted: _ Date Application Expires: PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 0004800015 Site Address: 13035 Gateway Dr BLDG 9 Suite Number: Floor: Tenant Name: BECU New Tenant: ❑ .....Yes O..No PROPERTY OWNER Name: BECU Address: 327 Tukwila Parkway City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Terese Anderson Address: 1221 2nd Ave N Cit': Kent State: WA Zip: 98032 Phone: (206) 200-7804 Fax: Email: tanderson@hermanson.com Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): See Attached Scope Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: 18,900 H:\Applicmions\Forms-Applications On Linc\2011 ApplicationsTlumbing Permit Application Rcviscd 8-9-1 I.docx Rcviscd: August 2011 bb PLUMBING CONTRACTOR INFORMATION Company Name: Hennanson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 200-7804 Fax: Contr Reg No.: HERMACL005BJ Exp Date: 08/16/2016 Tukwila Business License No.: BUS -0994464 Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Fixture Type t -Q, Drinking fountain or water 2 Bathtub or combination bath/shower t Dishwasher, domestic with I independent drain 4 Shower, single head trap Sinks 1 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water 2 cooler(per head Lavatory 4 Urinal 2 Water heater and/or vent 4 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic 2 Food -waste grinder, commercial Wash fountain Water closet 4 Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 2 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O)MR OR AUTHORIZED A NT: �1,� / Signature: ' Dater '1 f / � o Print Name: /�� /l^�� Day Telephone: �� 7_00 7-W{ f Mailing Address: ) Z-2-(2 ltT V� / `J Xj"P — 413 ll} % gel 3 Z city state Zip H:Wpplications\Forms-Applications On Line\2011 ApplicationsTlumbing Pcrtnit Application Revised 8.9-1 Ldoex Revised: August 2011 Page 2 of 2 Scope of Work Demo of (4) existing water closets to wall 0 Demo of (4) existing lavatories M Demo of (2) existing urinals M Demo of (1) existing drinking fountain M Demo of (2) existing sinks M Provide and install (4) new water closets, attach to existing carriers Ifl Provide and install (4) new lavatories M Provide and install (2) new urinals M Provide and install (1) new drinking fountain M Provide and install (1) new break sink M Provide and install (1) new garbage disposal • Provide and install (2) floor drains at restrooms, includes waste connection at approx. 10, • Provide and install (1) water filter system • Provide and install (1) under sink DW waste connection and water supply off of existing angle stop and waste. Provide and install (1) under sink icemaker water connection off of existing angle stop DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $363.36 PG16-0030 Address: 13035 GATEWAY DR BLDG 9 Apn: 0004800015 $363.36 PLUMBING $349.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $247.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $69.88 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7864 R000.322.900.04.00 0.00 $13.98 $363.36 Date Paid: Wednesday, March 09, 2016 Paid By: TERESE ANDERSON Pay Method: CREDIT CARD 262889 Printed: Wednesday, March 09, 2016 12:22 PM 1 of 1 rPSYSTEMS �G INSPECTION RECORD Retain a copy with permit INSPEUION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr 'erl Type of Inspection: Address: � � A�d r j"S Date C ed: qr S ecial Instructions: ed- _ a.m. p.m. Requester: Cbl y a .SW( Kerte o Phone . Iinspector: r--� Iuate6 —4—/K , f— K REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit F61X-0()3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Bay I�r'J P/- D to C ed: Special Instructions:FAte RD "a I Wanted: a.m. Y 6 -- 1k p.m. Re nester: � Phone No: / / �KJ J KjS-- t L__.I Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date` REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be, paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. T INSPECTION RECORD Retain a copy with permit 00 3 alEECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: 9�- Typ of Inspe tion: 0 Address: k > l !L/� � �.cf fX � to all 27 Special Instructions: S Date anted: a.m. p.m. Requester: � Phone No: IInspector: �/ �� IDate: 's --,s--/ L' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY Per -Wt N6. V(, ►.., - subject to errors and orr'_-!063. ao..uments doos, nc, Me, ,J; _,3 rto� --do os ordinan,o.�' of appro fz ' ; 0, J 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 R2 and R3 Revised June 2013 Project Info Project Address 1�' P Date 05/21/2013 For Building Department Use Applicant Name: IA I NAIV LY 11ilE—U 00D ytJ Applicant Address: i'C0r � 4yk A VE���. s �.-��. y ,i i` Applicant Phone: , _ �3-- qp ' �� .i Project Description New Building (.. ; Addition Alteration Plans Included Lighting Compliance Lighting Power Density Calculations Total Building Performance Path (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Building Area Method (s Space -by -space Method Compliance Option Interior Lighting System RECEIVED Description CITY OF TUKWILA MAR 0 9 2016 Briefly describe lighting system type and features. PERMIT CENTER Additions and Change of Space Use (C101.4.3 & C101.4.4) XAddition area or Change of Space Use area complies with all applicable provisions as stand alone project Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG -INT -SPACE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope _ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 New or moved lighting panel ntrols as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of 3. �Dr� MP`LIA 'r s unchanged or moved only McA ka ghting c ntrols as noted for New Wiring and commissioning of lighting controls per C405.13. b ade to e interior lighting and space use not changed. City Of Tukwila BUILDING Df VIS10N p 10.0010 CSE', 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 2012 Washington State Enerov Code ComDliance Forms for CnmmPrra1 ('-r„I,n R1 -,i I tet,..,, D� ....., — Project Info Project Address d``fkt_af - 1- JUI IC Lu 1) Date 05/21/2013 ✓_ For Building Department Use .Agplicant,Name: MXimu Allowed Lighting Wattage . Location (plan #, room #, or ALL) Space Type* Allowed Watts per ftZ Gross n error Area in ftz a s owe (watts/ft2 x area) I 1/04 Retail Display Lighting from LGT-INT-DISPLAY Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY oeiecr i aoie L,wvo. o-z(z) ca<egory rrom prop oown menu. Hrea Allowed Watts ** For atriums; indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht.,L above 40 feet is -0. 02 W/ft. ht. Total �' , C� A,A Proposed Liahtina Wattatee Location (plan #, Fixture Description Number of room #, or ALL) (Include exempt equipment per Note 3))- Fixtures Watts/ Fixture Watts Proposed ✓_ (i r I 1/04 Retail Display Lighting from LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts Notes: 1 For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. i 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 mmm = Itm MMEM =- -E a Lg I i I a !I 2012 Washington State Energy Code Compliance Forms for Commercial, GrouD R1. and > 3 story R2 and R3 0 Project Info Project Address Fill this line out on LGT-SUM U110 - 10 Date 05/21/2013 Fill this line out on LGT-SUM For Building Department Use Fill this line out on LGT-SUM Applicant Name: Fill this line out on LGT-SUM Maximum Allowed Display Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ftz ** Gross interior Area in ftz a s owe (watts/ftz x area) * Only areas within retail sales areas that contain separately controlled display Area Area Watts light maybe entered per Table .2(2) footnoteA. Total �— **From Table C405.5.2(2) footnotenote A.A. Display Allowance 0 Proposed Display Lighting Wattage Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3, A 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1 and > 3 story R2 and R3 Project Info Project Address Fill this line out on LGT-SUM Revisea uune 2u13 Date 05/21/2013 Fill this line out on LGT-SUM For Building Department Use Fill this line out on LGT-SUM Applicant Name: Fill this line out on LGT-SUM Do Not Enter Lighting Here. Use LTG -INT -SPACE Building Area Location (plan #, room #, or ALL) Area Description oweGross Watts per ft2 ` Interior Area in ft2z a s owe (watts/ft x area) Lighting Power Allowances per Table C405.5.2(1) Total Do Not Enter Lighting Here. Use LTG--] Location (plan #, Fixture Description Number of Watts/ Watts Building Area room #, or ALL) (Include exempt equipment per Note 5) Fixtures Fixture Proposed Notes: .. � __ r Proposed Wattage for each Budding Area type srali not exceed the Allowed v'Vattordye for that Building i ype. � raon;g waiiage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed -maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3� ® o a m ae as _ r 2012 Washinaton State Enerav Code Comolianre Forms fnr r m r, ,i r_r D1 z Project Info - - - Proj Addres Fill this line out on LGT-SUM mevisea June 1ul3 Date 05/21/2013 Fill this line out on LGT-SUM For Building Department Use Fill this line out on LGT-SUM Name: Fill this line out on LGT-SUM Appl. Name Appl.Phone Project Description New Addition Alteration Plans Included Lighting Zone (as specified by Jurisdiction) Zone 1 Zone 2 Zone 3 Zone 4 Compliance Option _' Lighting Power Density CalculationsTotal Building Performance Building Grounds-7Efficacy (luminaires > 100 Watts)Exemption > 60 lumens/W Controlled by motion sensor (list) Alteration Exceptions (check appropriate box -sec. C101.4.3.1) No changes are being made to the exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable exterior lighting controls (C405.2.4) and commissioning of lighting controls per C405.13 Tradable Maximum Allowed Lighting Wattage Base Site Allowance Tradable Surfaces owe Watts Area (ft2), perimeter Description per ft2 or per If (If) or # of items Tilowea Watts x ft2 (or x If) Total Allowed Tradable Watts: r rauauie r-ruYuseu Ligating vvartage (use mfgr listed maximum input wattage for)uminaire Number ofI Watts/ Surface Fixture Description Fixtures Fixture Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus Total Proposed Traaabie Watts the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed LightinLy Wattage Ra�zP Iifa All -m.— Ro,,,,;. ; Watts Proposed Non -Tradable Surfaces Description Allowed Watts Area (ft2), perimeter per ft2 or per If (If) or # of items Allowed Watts x ft2 (or x If) Watts Proposed iNon-iraaauie rroposeu Lignring VVattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed ver .0 P"j—,v —v u'ay "- on'❑nuvvcu wdus rU/ drly Incl/vlOual Total excess Non -Tradable watts: surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Site Allowance Balance: 2012 Washinqton State Enerov Code Dliance Forms for Commercial D R1, and > 3 stop R3 • • o • • • ' - 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 e Project Address Fill this line out on LGT-SUM Date 05/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes LIGHTING CONTROLS (Section C405.2) C405.2.1 Manual lighting Lighting control schedule with type, locations served, 50% controls lighting reduction method Lighting systems automatic shut-off capability - indicate C405.2.2.1 Automatic time method and location served on plans. Note locations where switch controls automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc Override switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF C405.2.2.2 Occupancy sensors Schedule of locations served C405.2.2.3 Daylight zones Vertical fenestration Primary and secondary daylight zone areas indicated on tans Skylights Skylight daylight zone areas indicated on plans 405.2.2.3, Daylight zone Lighting control schedule with dimming method and locations controls served - no single daylight control zone exceeds 2,500 SF Specific application Specific application lighting controls are independent of C405.2.3 controls general area lighting and controls for other lighting applications Means of egress Lighting control schedule with method and locations served. lighting Note luminaires that function as both normal and egress. Display lighting Lighting control schedule with type and locations served Accent lighting Lighting control schedule with type and locations served Hotel/motel guest Lighting control schedule with type and locations served rooms Supplemental task Lighting control schedule with type and locations served lighting Non-exempt lighting Lighting control schedule with type, applications served and equipment locations Non-exempt lighting Lighting control schedule with type, applications served and equipment locations C405.2.4 Exterior lighting Lighting control schedule with type, features and location controls served INTERIOR LIGHTING POWER (Section C405.5) C405.5.1 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture lighting power Space exceptions Space exceptions taken noted on plans or compliance form Lighting equipment Equipment exceptions taken noted on plans or compliance exceptions form C405.5.2 Lighting power calculations Building Area Method Compliance form completed — proposed wattage per building area does not exceed maximum allowed wattage Space -By -Space Compliance form completed — total proposed wattage does Method not exceed maximum allowed wattage C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side EXTERIOR LIGHTING POWER (Section C405.6 C405.6.2 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture lighting power Exterior application Exterior application exceptions taken noted on plans or exceptions compliance form Lighting power Compliance form completed — proposed wattage for exterior calculations lighting plus base site allowed does not exceed max. allowed C405.6.1 Exterior building Schedule with fixture types, lamps, ballasts, watts per fixture; grounds lighting lumens per watt for fixtures > 100 watts ELECTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1) •/ ,J 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1 •I I• ill• •owl 1111110.I Wi Eel cklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address Fill this line out on LCT -SUM Date 05/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes Electrical energy C409.2.1 consumption — whole Meters provided for whole building electric energy usage building Electrical energy C405.7 consumption — Individual dwelling unit electricity meters provided dwelling units C405.9 Transformers Indicate transformer size and efficiency on plans Variable speed C405.12.1 escalators and Variable speed controls provided moving walks C405.12.2 Regenerative drives r COMMISSIONING (Sections C405.13, C408.3, C409.4.4) C405.13 Commissioning Commissioning procedure developed for all applicable systems C408.3 Lighting controls Commissioning plan and functional test procedure developed C409.4.4 Electrical energy Commissioning plan and functional test procedure developed consumption meters Escalators & moving Commissioning plan and functional test procedure developed walks If "no" is circled for any question, provide explanation: HERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0030 DATE: 03/21/16 PROJECT NAME: BECU SITE ADDRESS: 13035 GATEWAY DR BLDG 9 X I Original Plan Submittal Response to Correction Letter #, Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: hi NO 1" Building Division ® Fire Prevention ❑ Planning Division ❑ Public Woks Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/22/16 Not Applicable ❑ (no approval review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved LI Structural Review Required ❑ DATE: DUE DATE: 04/19/16 Approved with Conditions [y Corrections Required ❑ Denied ❑ (corrections entered in. Reviews) (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2011 HERMANSON COMPANY LLP Home l.spahol Contract Safety & Health Washington State Department of Lab©r & Industries HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN,KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP Page 1 of 3 Search L&I N t A-7..Index Help My I,&I Claims & Insurance Workplace Rights Trades & Licensing 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County WA UBI No. Business type 602 004 844 Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. Meets current requirements. License specialties GENERAL License no. HERMACLO05BJ Effective — expiration 01/11/2000— 08/25/2016 Bond ................ WESTERN SURETY CO $12,000.00 Bond account no. 929381801 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACLO05BJ&SAW= 4/27/2016