Loading...
HomeMy WebLinkAboutPermit S14-0027 - WING STOP - BUILDING MOUNTED SIGNS (NULL)WING STOP 17405 SO UTH CE NTE R PKWY S14-0027 2 PERMANENT BUILDING MOUNTED SIGNS City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188- - Phone: 206-431-36701�iri>J'G LI .li��P►.-{ _ •-�" . Inspection Request Line: 206 -438 -9350 - Web site: http://wvfw.TukwilaWA.eov PERMANENT SIGN PERMIT Parcel No: 2623049067 Permit Number: 514-0027 Address: 17405 SOUTHCENTER PKWY Issue Date: 4/11/2014 EXPOSED BUILDING FACE: Permit Expires On: 10/8/2014 Owner: METHOD OF LIGHTING: LED Name: CLPF-TUKWILA LP Address: 10655 NE 4TH ST #901 C/O JSH PROPERTIES INC, BELLEVUE, WA, 98004 Contact Person: Name: BILL BOAD Phone: Address: CAPITOL AWNING PO BOX 8106, LACEY, WA, 98509 Contractor: Name: CAPITOL SIGN & AWNING Phone: (360) 493-6070 Address: PO BOX 8106, LACEY, WA, 98509 License No: CAPITSA873DF Expiration Date: 3/6/2015 Business: Name: Address: DESCRIPTION OF WORK: 2 ILLUMINATED BUILDING MOUNTED SIGNS 1) NORTH ELEVATION 1) WEST ELEVATION Fees Collected: $499.80 Zoning: TUC Electricity Provided by: PUGET SOUND ENERGY Types of Sign: 495 1. BUILDING -INCENTIVE SIGNAGE 19.8 LOCATION OF ENTRANCE: East EXPOSED BUILDING FACE: 1224 SIGN AREA: 19.8 METHOD OF LIGHTING: LED 2. BUILDING -INCENTIVE SIGNAGE LOCATION OF ENTRANCE: North EXPOSED BUILDING FACE: 495 SIGN AREA: 19.8 METHOD OF LIGHTING: LED Planning Division Authorized Signature: ��L�1��aZ&i\ Date: 6 / ` /— I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law agt-EE NeeE v1gE ng th i� SIG�ru plied with, whether specified herein or not. Signature: FOR PEWW 0� Date: Print Name: THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-438-9350. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. Electrical inspection shall occur independent of this permit. FINAL INSPECTION APPROVAL: DA SITE INSPECTION (PLANNING) File No. S14-0027 Name of Tenant: WING STOP Sign Address: 17405 Southcenter Pkwy Date Photo Taken: Jun 27, 2014 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. MB 6-27-14 J - Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets at least one of the following design criteria: 1. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an unobstructed view into the business or use or a display window with a depth of at least three feet. 2. Architectural detailing consistent with the building design using changes in color, materials, texture, and variations in the wall plane. 3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the wall surface. If the artwork uses words or images related to the business on site they will be considered part of the sign area. 4. One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. Signs permitted under this Section may be up to 50 percent of the area calculated in the Table in Section 1. Dn 3- Proiectini2 and Canonv Edgc One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualify for a projecting or canopy edge sign. Projecting Sign % Reserved for For more detail see the Sign Code Language, TMC Sign Sign Sign City Use 19.20.050 F 4. Wall Area Maximum area permitted is 20 square feet per face and 40 square feet Area of Sign The size of the sign is based on the area of the wall total for all faces. I Z L4 qq fronting the tenant space where the sign will be Extends from located, see 19.08.110. Maximum Height above Calculate the maximum sign area allowed for the Sign Area The bottom edge of the sign must be at least eight feet above the ground wall from the Table in Section 1 and reduce by sidewalk or walkway that it overhangs. Rotating half. Proposed ii q p r Calculate the area by drawing one box around the Area of Sign Sign Copy entire sign face or copy using 90 degree angles. Sign Copy tit U �` List what the sign will say (for example name of W�E H business). Dn 3- Proiectini2 and Canonv Edgc One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualify for a projecting or canopy edge sign. Projecting Sign Canopy Edge Sign Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. Reserved for For more detail see the Sign Code Language, TMC 19.20.050 C. Sign City Use 19.20.050 E. Proposed Maximum area permitted is 20 square feet per face and 40 square feet Area of Sign total for all faces. Distance Sign The sign may not stick out more than four feet from the building wall. Extends from Also, the sign can't extend further than the sidewalk it overhangs. Building Height above The bottom edge of the sign must be at least eight feet above the ground sidewalk or walkway that it overhangs. Rotating Mechanical rotating displays are permitted. Display Proposed Sign Copy List what the sign will say (for example name of business). Canopy Edge Sign Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Building Mounted Sign-May2011.doc Reserved for For more detail see the Sign Code Language, TMC Sign _ City Use 19.20.050 E. Height of Maximum height allowed is 12 inches letters Length of The sign length is limited to 2/3 of the length of the Canopy canopy. Length of Sign Proposed The letters may be lit, specify whether and how this is Lighting proposed. Sign Copy List what the sign will say (for example name of business). W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Building Mounted Sign-May2011.doc now- �,. L_ -ding Mounted Signage Workshy. The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs, see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size of your wall sign: Maximum Sign Area AREA (LxH) of Exposed Building Face (EBF) in square feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF -500) x .04 + 25 square feet 1501-3,000 (EBF -1,500) x .03+ 65 square feet 3,001-5,000 (EBF -3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet Awning Face Sign Worksheet Reserved for For more detail see the Sign Code Language, TMC Sign Sign City Use 19.20.050 A. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Calculate the maximum sign area allowed for the Sign Area wall from the table above. Proposed Calculate the area by drawing one box around the Area of Sign entire sign face or copy using 90 degree angles. Sign Copy List what the sign will say (for example name of Proposed business). Awning Face Sign Worksheet 1 This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Building Mounted Sign-May2011.doc Reserved for For more detail see the Sign Code Language, TMC Sign Sign City Use 19.20.050 B. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see TMC 19.08.110. Maximum Calculate the maximum sign area allowed for the Sign Area wall from the table above. Area of The size of an awning face sign is limited to the Awning Face area from the table above or 30% of the area of the face of the awning, whichever is smaller. Proposed Calculate the area by drawing one box around the Area of Sign entire sign copy using 90 degree angles. Lighting Only indirect lighting maybe used for awning face Type signs. Awning In commercial zones awnings may only be made of Material canvas or nylon fabric. Sign Material Signs may only be vinyl or paint applied directly to the awning. Sign Copy List what the sign will say (for example name of business). 1 This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Building Mounted Sign-May2011.doc CITY 4 TI7KWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670FAX(206) 431-3665 E-mail: Planning TukwilaWA.gov 'ERMANENT x � BUILDING MOUNTED SIGNS FOR STAFF USE ONLY Permits Plus Type: P-SIBLDG Planner: File Number: LT— 6a Needs Electrical: Yes/No Associated File Numbers: Z7Z_ L S4p Lh Business Name I Address of Sign WA 18� Contact Name Address City, State, Zip address ) �q-? (a®7. Contact Phone number Contractor Cont actor State License # Contractor's City of Tukwila Business Lic # Contractor AddressCity St Zip I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit. dW bo /Ai P 0E - Date: Signature of Owner or Authorized Agent Email The City will send any official notices, letters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ O Completed and signed application (this form). O Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted signs on the same building as the proposed signs. O Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. O Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. O Three copies of a scaled and dimensioned building profile, if projecting signs are proposed. O Method of illumination, if proposed. O Method of support and attachment for building - mounted signs. O Structural calculations if the sign weighs over 400 pounds. O Application fee listed in current Fee Schedule. O One copy of a valid Washington State Contractor's license, or owner's affidavit. O Valid Tukwila business license number for the sign contractor. TOTAL NUMBER OTSIGNS Total number of signs included in this application: Section 1 RECEIVED APR 08 2014 Section 3 (,OV''J .1NI I 1 it `JI LOPMENT Section 2 P\,-,2 Section 4 W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Building Mounted Sign-May2011.doc 1Ngwrf0I:IA i(J A I iNr)nOjOJ %OZ 80 MY ODAlDa3L4 Slq.-Oa,Z> Ito ch,riges can bo made tP these plan3 `vifhout approval from the planning Division of DCD A ApprovedY) Date: 4 I c> E 3 � au , Id C ,j i C= 00 i 0 S 7 1 1/2" 5" 1/2" s i - Plan View — - 14'-0" 1.'t1/9" I T 17" 1 Sign B: Led Illuminated Pan Channel til Reverse -Pan Sign copy: (p/c) white acrylic letter faces with Arlon #5590-4307 'perforated day-nite" vinyl overlay. 5" deep brush aluminum returns with 1 " brushed aluminum trimcap. white ul approved Led illumination. peg -out 1/2" off bldg fascia. decor bars & dot: (reverse -pan) 4" deep aluminum fabricated painted silver metallic. ul approved white ul approved Led illumination. clear lexan backs. 1 1/2" peg -out. PROPOSED sign size shown approx per bldg measurements C4A [ remove & junk existing s (patch & paint by others) 1 112"peg—t - . ; _^V. 4" deep affum. return #8z3' wand screw ./plastic shield iR"lefterpeg-out —F (min. 3 per letter) (ul approved) 12 volt wiring #0x3" wood screw aluminum return - - — w/plastic shield clear lexan bac power unit (min. 3 per letter) (, �.— 120 v to bldg acrylic lace 72 volt wldng led Illumination 12 volt (ul appm'md) power supply 4" electrical wires —120 v to bldg 4„ hlmcap - weep holes building fascia 4" Led P/C Letter Mounting Detail (w/peg-out) 1 112"peg—t - . ; _^V. 4" deep affum. return #8z3' wand screw ./plastic shield led Itluminaflan (min. 3 per letter) (ul approved) 12 volt wiring aluminum tote - 12 volt clear lexan bac power unit 118' alum, bkgd t (, �.— 120 v to bldg weep holes I , b0olna testle Reverse Pan Led Hato Mounting Detail