Loading...
HomeMy WebLinkAboutPermit S14-0044 - OVERSTOCK FLOORING - FREESTANDING SIGNOVERSTOCK FLOORING 131 ANDOVER PARKE S14-0044 1 PERMANENT FREESTANDNG SIGN City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 " Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htti)://www.TukwilaWA.gov PERMANENT SIGN PERMIT Parcel No: 0223100035 Permit Number: S14-0044 Address: 131 ANDOVER PARK E Issue Date: 6/30/2014 Permit Expires On: 12/27/2014 Owner: Name: MCLAUGHLIN & BUTY LLP Address: 1150 ALKI AVE SW APT 4 BUTY FRANK GENERAL PARTNER, SEATTLE, WA, 98116 Contact Person: Name: JOSE MARTINEZ Phone: (206) 849-4209 Address: PO BOX 3505, SEATTLE, WA, 98124 Contractor: Name: GRAPHIC DISPLAY SIGN & AWNING Phone: Address: PO BOX 3505, SEATTLE, WA, 98124 License No: GRAPHDS881WP Expiration Date: Business: Name: OVERSTOCK FLOORING Address: 131 ANDOVER PARK E ... DESCRIPTION OF WORK: MONUMENTSIGN�(� Fees Collected: $249.90 Zoning: TUC Electricity Provided by: PUGET SOUND ENERGY Types of Sign: 1. FREESTANDING -COMMERCIAL STREET NAME: Evans Black Dr SIGN AREA PER FACE: 53.72 SIGN AREA PER SIGN: 107.44 WIDTH OF SIGN: SIGN HEIGHT: SETBACK: STREET FRONTAGE: Planning Division Authorized Signature:. Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: �N "` Date: Print Name: 15 G%� THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE [>��IgI��I��iI:�P►II To schedule a final inspection for your sign, please call the inspection request line at 206-438-9350. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. Electrical inspection shall occur independent of this permit. FINAL INSPECTION APPROVAL: DATE: SIGN INSPECTION (PLANNING) File No. S14-0044 Name of Tenant: Overstock Floorin, Sign Address: 131 Andover Park E Date Photo Taken: Dec. 2, 2014 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign appears to conform to approved permit. CP Table 1, Monument Sign Details, Commercial/Industrial Zones Freestanding Signs in Residential Zones Institutional uses and multi -family complexes are allowed to have one monument sign for each public street that provides access to the premises. The following are the specific development standards that apply to the installation of monument signs in residential zones: 1. The area of the monument sign is limited to 30 square feet per sign face and a total of 60 square feet for all sides; 2. The sign may be up to five feet tall; 3. Maximum width of the sign shall not exceed 15 feet; 4. Location of the sign shall not interfere with sight distance of vehicles pulling in and out of the premises; 5. The sign must be located in a landscaped area. Having the sign stand-alone in a parking lot is not permitted; and 6. The sign may only use indirect lighting methods except for dynamic displays. The lighting must have no spill-over impact on adjacent properties. Dynamic Signs in Residential Zones In order to foster civic community outreach and communication, the City permits limited use of dynamic signs within residential zones. One permitted monument sign per premise, as outlined above, may contain a dynamic feature. The following are the specific development standards applicable to the installation of dynamic signs within residential zones: 1. The image of the sign may not change more frequency than once every ten seconds; 2. The image must appear and disappear as one image. The image may not appear to flash, undulate, pulse or portray explosions, fireworks, flashes of light, or blinking or chasing lights, or appear to move toward or away from the viewer, expand, contract, bounce, rotate, spin, twist, scroll, travel or otherwise portray movement. 3. Illumination of the dynamic sign is limited to the hours of 7AM to IOPM. 4. All signs shall have installed ambient light monitors, and shall at all times allow such monitors to automatically adjust the brightness level of the electronic sign based on ambient light conditions. Maximum brightness levels for electronic signs shall not exceed 3 -foot candle above ambient light conditions, measured 100 feet from the face. Tabe2, Monument Sign Details, Residential Zones Monument Monument Monument Monument Monument Monument Sin 1 Sign 2 Sin 3 Sign 4 Sin 5 Sign 6 Name of Street &//� t4S will be placed on which sign &AG/Gd2 along? will be laced? Total Area of Total Sign message area Sign Height per face. (feet -inches) Width of Sign. &V have a Total Sign message area Dynamic per sign. Display? Total Sign Size face 53 72 per Total Sign Size G� t� C per sign. ` l Width of Sign Sign Height 5` S feet -inches Distance from closest edge of sign to property lines in feet Freestanding Signs in Residential Zones Institutional uses and multi -family complexes are allowed to have one monument sign for each public street that provides access to the premises. The following are the specific development standards that apply to the installation of monument signs in residential zones: 1. The area of the monument sign is limited to 30 square feet per sign face and a total of 60 square feet for all sides; 2. The sign may be up to five feet tall; 3. Maximum width of the sign shall not exceed 15 feet; 4. Location of the sign shall not interfere with sight distance of vehicles pulling in and out of the premises; 5. The sign must be located in a landscaped area. Having the sign stand-alone in a parking lot is not permitted; and 6. The sign may only use indirect lighting methods except for dynamic displays. The lighting must have no spill-over impact on adjacent properties. Dynamic Signs in Residential Zones In order to foster civic community outreach and communication, the City permits limited use of dynamic signs within residential zones. One permitted monument sign per premise, as outlined above, may contain a dynamic feature. The following are the specific development standards applicable to the installation of dynamic signs within residential zones: 1. The image of the sign may not change more frequency than once every ten seconds; 2. The image must appear and disappear as one image. The image may not appear to flash, undulate, pulse or portray explosions, fireworks, flashes of light, or blinking or chasing lights, or appear to move toward or away from the viewer, expand, contract, bounce, rotate, spin, twist, scroll, travel or otherwise portray movement. 3. Illumination of the dynamic sign is limited to the hours of 7AM to IOPM. 4. All signs shall have installed ambient light monitors, and shall at all times allow such monitors to automatically adjust the brightness level of the electronic sign based on ambient light conditions. Maximum brightness levels for electronic signs shall not exceed 3 -foot candle above ambient light conditions, measured 100 feet from the face. Tabe2, Monument Sign Details, Residential Zones W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Freestanding Sign-updated.doc Monument Sign Monument Sign 2 Monument Sign 3 Monument Sign 4 1 Name of Street in which sign will be placed along? Total Area of Sign. Sign Height (feet -inches) Width of Sign. Will the sign have a Dynamic Display? W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Freestanding Sign-updated.doc 3eneralInformation about Property Total Length of Street Frontage Along All Streets. Allowable Sign Does the site front on more than one street, but have less than 800 feet of linear frontage, combined on both streets? Maximum Is the site use a multi family or institutional use in a residential zone (LDR, MDR, or HDR)? Message Area' Sign Size' A sign permit is required for the installation of a new freestanding sign. In most circumstances the City only allows new freestanding signs to be monument style signs. Certain large premises that have gone through the Master Sign Program are eligible for grand monument signs. Information on installing a new freestanding sign is found in SECTION 1 of this application. Information on installing new grand monument signs can be found in SECTION 2 of this application. A sign permit is also required for any proposed reface or copy change to an existing freestanding sign in the City. In some cases a reface or copy change of an existing freestanding sign requires that the sign be removed. Information on completing a reface or doing a copy change to an existing freestanding sign can be found under SECTION 3 of this; application. Freestanding Signs in Commercial/Industrial Zones Each premise is permitted to have one freestanding -monument style sign. Additional monument signs are permitted based on the total amount of linear street frontage along the premise. Table 1 below outlines the development standards and total number of signs permitted for most premises. Total ROW of Premise Allowable Sign Total Allowable Maximum Number of Signs Message Area' Sign Size' Height Less than 400 36 square feet per 54 square feet per feet side/72 square feet side/108 square feet 6 feet One total total 400-599 feet 50 square feet per 70 square feet per side/100 square feet side/140 square feet 7 feet One total total 600-799 feet 60 square feet per 80 square feet per side/ 120 square feet side/160 square feet 7 feet One total total 800-999 feet 66 square feet per 88 square feet per side/132 square feet side/ 176 square feet 8 feet Two total total 1,000 feet and 72 square feet per 96 square feet per One for every 400 feet of over side/144 square feet side/192 square feet 8 feet linear street frontage. total total Corner Properties Some corner properties may qualify for more than one monument sign, even if they have a limited amount of street frontage. A property that borders on more than one public street, but has less than 800 total feet of linear frontage, is permitted to have one monument sign per street if the following criteria are met: 1. The property has a least 200 feet of frontage on each public street where a sign will be placed; 2. Each public street provides direct access to the property; and 3. For each separate street frontage Table 1 listed above shall be used to determine the design standards for any proposed monument sign. General Requirements for Monument Signs in Commercial and Industrial Zones 1. Setback. All monument signs shall be placed at a minimum of five feet from all property lines; however no sign taller than three feet shall be placed within the sight distance triangle, unless it can be demonstrated the sign will not pose a safety risk by reducing visibility for motorists turning out into traffic. 2. Maximum Width. The maximum width permitted for any new monument sign is 15 feet, 3. Address Requirement. All new freestanding signs shall have the address number or address range of the premise listed on the structure. The address shall not be counted toward the allowable sign message area limit. Address numbers must be plainly legible and visible from the street fronting the property. The address numbers must contrast with the sign background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches high with a minimum stroke width of 1.5 inches. ' The allowable message area is either the face pane of the sign, or for channel letters or signs painted on seating or retaining walls, that portion of the sign devoted to the actual message, logo, or business name. Z Total size is the entire area of the sign, including the support structure. W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Freestanding Sign-updated.doc CITY 0 TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: Planning@TukwilaWA.gov rAj ` 'ERIVIANENT FREESTANDING SIGNS FOR STAFF USE ONLY Permits Plus Type: P-SIFREE Planner: File Number: --O® �•` 4L lG) tO Needs Electrical: es o 3 J CITY 0 TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: Planning@TukwilaWA.gov rAj ` 'ERIVIANENT FREESTANDING SIGNS FOR STAFF USE ONLY Permits Plus Type: P-SIFREE Planner: File Number: --O® Needs Electrical: es o 3 Associated File Numbers:Z!)l Ld —/Y) C43 0U&,S TO Gid t���/�l 7 Business Name Address of Sign Contact Name Address 131 dp 010(16,p- pa,� 1-3ox 3-6-0!!5 6& -fl -77-F, W11f City, State, Zip Contact Email addres Contact Phone number (�" ZC� A /V (51ell-j -e�, sop/ ontraAor Contractor State License # Contractor's City of Tukwila Business Lie # y Contractor Address v 140A� City St Zip 5'�"" �( I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit r, if the ermit has been issued, be causer the City to revoke sign permit. Date: Si 6 ature of O ne or Authorized Agent Email The City will send any official notices, letters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ O Completed and signed application (this form). O Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing freestanding signs on the premise and proposed location for any new freestanding sign(s). O Method of illumination, if proposed. O Scaled and dimensioned footing designs and height calculations. Footing designs are not required for reface or copy changes to an existing freestanding sign, provided there is no change in the sign height, area or location. O Structural calculations if the sign has an area greater than 50 square feet and/or is taller than 15 feet. This requirement may be waived for certain refaces or copy changes to existing freestanding signs. O Application fee listed in current fee schedule. O One copy of a valid Washington State Contractor's license or owner's affidavit. O Valid Tukwila business license number for the sign contractor. TOTAL NUMBER OF SIGNS Total number of signs included in this application: Section 1 Section 2 Section 3 Section 4 JON 10 2014 W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Freestanding Sign-updated.doc (�1. V'-LUIUl N I .FA • 01,6611: ELECTRICAL REQUIREMENTS s -r . 9'-11" _ � � .`r. ►� LONG Ili •)S]i0111:440: THIS DESIGN IS THE EXPRESS PROPERTY OF GRAPHIC DISPLAY SIGN CO. AND IS PROTECTED BY FEDERAL COPYRIGHT LAWS. ANY REPRODUCTION OF A SIGN SIMILAR TO THE DESIGN REPRESENTED HERE IS FORBIDDEN. SHOULD THIS OCCUR, GRAPHIC DISPLAY 15 DUE $1000.00 AS COMPENSATION 9'-11" LONG �--- Lexan face with translucent inyl V��STOO FLOORING �+ 9'-11.75" - LONG Monument Sian Install Details 3/4" = 12" sign square area 65" x 119" 53.71 square feet Graphics Sign Area 21.45 Square feet 07RA* PHIL 6545 5th Avenue S. DISPLAYSeattle, WA 98108 SIGNCOMPANV 0 (206) 7680670 VOLTS 20 AMP CIRCUITS TOTALAMPS face withtransl Ron Walker - Operations Manager Longhua USA ' ron@trueflooring.con1 c206.730.4603 I New Corporate Location 16040 Christensen Rd Tukwila, WA 98 I) 12° side view dimension of sign I --I n r- 1 131, a R.- 0 11 � �f�PP1-o va/ ON!= �a LIGHTING to be GE LED pods as needed for even illumination PLANNING APPROVED No changes can be made. to these plans without approval from the Planning Division of DCD Approved By: Date: 1/8" painted aluminum cabinet 4" steel pole 1/8" formed aluminum End View Page 5of5 Use Existing Power � Ground O (2) concrete holes 24"x24" x 36" deep RECEIVED JUN 2a 2014 r.OMMUNI I Y