Loading...
HomeMy WebLinkAboutPermit S14-0085 - SOUND TRANSIT / SOUNDER STATION - FREESTANDING SIGNSOUND TRANSIT SOUNDER STATION 7301 LONGACRES WAY S14-0085 1 PERMANENT FREESTANDING SIGN City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.aov PERMANENT SIGN PERMIT Parcel No: 0005800020 Permit Number: S14-0085 Address: 7301 LONGACRES WAY Issue Date: 10/31/2014 Permit Expires On: 4/29/2015 Owner: Name: CPSRTA (SOUND TRANSIT) Address: 401 S JACKSON ST, SEATTLE, , 98104 Contact Person: Name: KYM WILLIAMS Phone: Address: Contractor: Name: OWNER AFFIDAVIT ON FILE Phone: Address: License No: Expiration Date: Business: Name: SOUND TRANSIT SOUNDER STATION Address: , , , DESCRIPTION OF WORK: RESUBMITTAL OF S12-092 (1) FREESTANDING MONUMENT AT TUKWILA SOUNDER STATION Fees Collected: $249.90 Zoning: TUC Electricity Provided by: PUGET SOUND ENERGY Types of Sign: Planning Division Authorized Signatur Date: I hearby certify that I have read and examined thi permit and know the same to be true and correct. All provisions Qf IwAi and nrriinanrec governing this work gill be complied with, whether specified herein or not. ACCEPTANCE BY EMAIL Signatu Print N; Date: THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-438-9350. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. Electrical inspection shall occur independent of this permit. FINAL INSPECTION APPROVAL: DATE: SIGN INSPECTION (PLANNING) File No. S14-0085 Name of Tenant: Sound Transit Sounder Station Sign Address: 7301 Longacres Way Date Photo Taken: Dec. 8. 2014 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments:.. Sign appears to conform to approved permit. CP CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 i PERMANENT SIGNS Building and Free -Standing / Monument Short Form — COMMERCIAL ZONE ONLY FOR STAFF USE ONLY Planner: File Number: 1 Needs Electrical: Yes/No Associated File Numbers: �) Sound Transit_ Business Name Kym Williams - Contact Name 7301 Longacres Way. Address of Sign 401 S Jackson St Address Seattle, WA 98104_ City, State, Zip kym.williams@soundtransit.org (206) 398-5156 Contact Email address Contact Phone number Contractor Contractor Address Contractor State License # Contractor's City of Tukwila Business Lic # City St Zip = UIRED FOR SIGN APPLICATION O Valid Tukwila business license number for the sign contractor. O One copy of a valid Washington State Contractor's license, or owner's affidavit I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit. _10/22/14 Date: SiIre of Owner or Authorized Agent The City will send any official noticeers, and other official notices via email. If you wish to receive all official communications from the City via Utal Mail, check here: ❑ O Completed and signed application (this form). Application fee listed in current Fee Schedule O Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted or freestanding signs on the same building/parcel as the proposed signs. O Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. O Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. O Method of illumination, if proposed. O Method of support and attachment for building -mounted signs. O Structural calculations if the sign weighs over 400 pounds. O Scaled and dimensioned footing designs and height calculations. Footing designs are not required for reface or copy changes to an existing freestanding sign, provided there is no change in the sign height, area or location. O Structural calculations if the sign has an area greater than 50 square feet and/or is taller than 15 feet. This requirement may be waived for certain refaces or copy changes to existing freestanding signs. Total number of Building mounted sign included in this application: Total number of Freestanding/Monument Signs included in this application:_1 C:\Users\wilhamsk\AppData\Local\Microsoft\Windows\Temporary Internet Files\ Content.Outlook\Q4G7K245\Sign - Combo - A-lonunien t-BIdoc GENERAL The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)438-9350. The 4 -digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs; see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Section 1- Wall Sign Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size of your wall sign: Maximum Sign Area AREA (L x H) of Exposed Building Face (EBF) insquare feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF -500) x.04 + 25 square feet 1501-3,000 (EBF -1,500) x .03+ 65 square feet 3,001-5,000 (EBF -3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet ' This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. C:\Users\williamsk\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\Q4G7K245\Sign - Combo - Monument-Bldg.doc Reserved for For more detail see the Sign Code Language, TMC Sign Sign City Use 19.20.050 A. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Calculate the maximum sign area allowed for the Sign Area wall from the table above. Proposed Calculate the area by drawing one box around the Area of Sign entire sign face or copy using 90 degree angles. Sign Copy List what the sign will say (for example name of business). ' This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. C:\Users\williamsk\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\Q4G7K245\Sign - Combo - Monument-Bldg.doc o W -;iR'ECEIVEM o o d OCT 24 2014 ti t g ca Z < = `o COMMu(vi 1 ) W t C Z Z� DEVUL,U{'MkN C N ►.. V ,v� o� �`•� 33Ll 3 A— JIL ASE rr aaQ 10 uol9w(3 oyl woo pAoiddle V% � d ®cso:'l ol'epBW eq U'' Wt to f� �lddV. o tNNV =d G a o V _ d GCO _ u� f.�b y it fu ici� QNY� I `` r•N RrO, me CP r dap V; I Q � oaoa. . , CL 41; rnae,~ r y a) teIm a. y dGld� in o004 3 ���►- ', a o � M _V J ,• �a awes � 3 u v �� , i T :A .4 111A l I r '- r r s p Q 0 0 rrs""o 7 • 2 • M N � v a t a 1 w a RECEIVED PLANNING APPROVED OCT 24 2014 No changes -can be made. to these C,0MM1)N1 I T I plans without approval from the DE VELUI'NT ME � Planning Division of DC 1 Approved _ Dater 1 1 1 1 1 I '1TA9J iaaw U1eL'Y lJ.wl-�' _ .. 1 ;II!!III 1 LFM=�512L1 G—n-01 W lY .d U Q o J TRANSIT SIGNAGE PLAN 2 SCALE: 1 /16' - 1'-0• TK-AI.0 1 ie 4 0 8 16 SHEET NOTES I. FOR LOCATION OF LIGHT POLES SEE FOR REFERENCE ELECTRM FOR LOCATION OF SIGN SCALE IN FEET POLES. SEE CIVIL SIGNAGE PLANS ![ STATIONING CONTRACT 2. SEE SHEET GSo.01 FOR GENERAL NOTES. _ 3. FOR REGULATOR AND OTHER SIGHS. N SOUND SEE SHEETS TK-CM.01-TKOI.06 AND Drawing No.: TK—GS 1.02 TK -A11.12. e LFM=�512L1 G—n-01 W lY .d U Q o J TRANSIT SIGNAGE PLAN 2 SCALE: 1 /16' - 1'-0• TK-AI.0 1 ie 4 0 8 16 THIS SHEET IS FOR REFERENCE ONLY- SCALE IN FEET Z .. NOT PART OF CONTRACT KEY PLAN 0 430 2013 ISSUED FOR CONSTRUCTION Designed By.Seale: N SOUND TRANSIT TUKW I LA STATION Drawing No.: TK—GS 1.02 EP WS Drawn By. - - » Consulting Engineers irm Filonome: TUKW I LA, WASHINGTON H E W I TT TIC -GS I OZDWG -- D5Rh Aw,ue. SO# 1600 CNw, Checked By. sm�a - 1 51122 ForOW (206) 622-6130 � � Contract Na.. cNol43-12 TRANS i T SIGNAGE PLAN 2 R.�.: L __ 237 0 Approved By. Submitted 0. TIMPSON Dotr. Approved: 4/30/2013 J. O'HARE polo Date; 4/30/2013 11/9/20121 No Date B Chk: Revhlons DH NEGEIVED OCT 24 2014 C(,.."1I:-,.. — i A If LO AML -14 t 24" dia. 1'-41/4" dia. T- 11/161, 5 ID 11/16" 5.563" ------------- --------I CV r Vertical Support 5" schedule 40 aluminum pipe into Base and secured with Set Screws, B Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. C Large Base CD -9 (see CP3.0) A Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. D Anchors Four (4) 3/4" dia. x 24" min. embed anchor bolts set with template \\\\ \\\\ \\\\ �I Rebar (3) #3 hoop ties @ 4" o.c. o (6) #4 vertical ties fa E - cli 24" dia. 1'-41/4" dia. 7, 11/16" 1 ,- 55/8-1 5/8" ID _11/16" 5.563" p p C <� A Vertical Support to - - - - - - - - - - - - - 5" schedule 40 aluminum pipe int' Base and secured with Set Screws pLANNli'+IC I c�`-janges'CSn r,s without 0 Planning Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. <C Large Base CD -9 (see CP3.0) A Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. Anchors Four (4) 3/4" dia. x 9" min. embed anchor bolts set with template r these 1�1 the I OC. D 24" dia. 7„ 11/16'~ 5 5 8" ID 11/16" Z E� Rebar N N (3) #3 hoop ties @ 4" o.c. (6) #4 vertical ties N r 2 Vertical Section View / A1.0 & A1.1 Second Pole Drilled Footing 3 Plan View / A1.0, A1.1, A2.0 & A2.1 Drilled Footing Scale: 1 1/2" = 1'-0" Scale: 1 1/2" = 1'-0" S/v- ooffs' M;r-rw' SOUNDTR,4NSR January 29, 2002 D A T E A July 29, 2003 February 7, 2004 0 REVISIONS [ J Approved [ J Approved with changes notes CUSTOMER SIGNATURI D A T E Sign Production Drawings A1.01 A1.19 A2.0 & A2.1 Vertical Section View / A1.0, A1.1, A2.0 & A2.1 Drilled FootingI Drilled Foundation 1 Scale: 1 1/2" = 1'-0" Detail