Permit PL13-001 - INTEGRA TELECOM - FIBER OPTIC UTILITY SERVICE
INTEGRA TELECOM 3355 S 120 PL PL13-001 L13-001 SPECIAL PERMISSION SENSITIVE AREAS City of Tukwila Jim Haggerton, Mayor Department of Community Development NOTICE OF DECISION TO: King County Assessor's Office, Christie.Most@kingcounty.gov Joanna Spencer, City of Tukwila Joanna.Spencer@TukwilaWA.gov File L13-001 Jack Pace, Director February 19, 2013 This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L13-001 Applicant: Eric Clayton, Integra Telecom Type of Permit Applied for: Special Permission from the DCD Director requesting a Critical Area Sensitive Area Ordinance Deviation to allow permanent utility equipment in wetland and creek buffers Project Description: Integra Telecom is proposing to install fiber optic utility service within the City of Tukwila. The portion of the underground installation proposed along 133rd Street is within critical area buffers. Temporary impacts within these buffers include a 25 square foot area for placement of a temporary bore pit and a permanent "hand hole" for utility access. Location: 1. At the southbound on ramp to SR599 within a category III wetland buffer. 2. At the northeastern corner formed by the intersection of S133 St and S 131" Place within a Category IV wetland buffer and within the Southgate Creek stream buffer. Associated Files: PW 12-088 II. DECISION SEPA Determination: The SEPA Responsible Official has determined that the project is categorically exempt. Decision on Substantive Permit: The Community Development Director has determined that the application for a Special Permission to deviate from the City's Sensitive Areas Ordinance does comply with applicable City and state code requirements and has approved that application based on the findings and conclusions contained in the staff report, and subject to the following conditions: SM Page 1 of 3 H:\L13-001 Integra Telecom\L13-001 Integra Telecom NOD.doc 02/19/2013 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 1. No vehicle parking, including parking on paved areas, is allowed in sensitive steam and wetlands and their buffers. The "no parking" areas are generally along South 133rd Street from SR 599 through South 130 Place and are shown on the map included as Attachment A and highlighted in blue, green and purple -gray. 2. The area adjacent to the SR 599 on ramp shall be reseeded with a native grass seed mix. 3. The permanent "hand hole" installation shall be mitigated with the planting of 10 2 -gallon red osier dogwood along the Southgate Creek stream edge. A three foot planting area around each plant shall be grubbed out to remove the reed canary grass root system. The area should not be mulched. 4. Integra shall perform an annual inspection and provide an annual monitoring report of the plantings along Southgate Creek. The monitoring report shall note if any mitigation plantings have failed to thrive. Any plants that are not thriving shall be replanted under the same guidelines of this mitigation requirement. Monitoring shall continue until each original and any replacement plants have survived for three consecutive years. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 2 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. One administrative appeal to the Hearing Examiner of the Decision on the Permit itself is permitted. A party who is not satisfied with the outcome of the administrative appeal process may file an appeal in King County Superior Court from the Planning Commission decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director's decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision; that is by March 5, 2013. The requirements for such appeals are set forth in Tukwila Municipal Code 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $563. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as an open record hearing before the Hearing SM Page 2 of 3 H:\L13-001 Integra Telecom\L13-001 Integra Telecom NOD.doc 02/19/2013 Examiner based on the testimony and documentary evidence presented at the open record hearing. The Hearing Examiner decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW 36.70C. An appeal challenging a DNS may be included in such an appeal. If no appeal of the Hearing Examiner decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Stacy MacGregor, who may be contacted at 206-433-7166 for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. The notice board must be removed at the expiration of the appeal period if no appeal is filed. Department of Community City of Tukwila opment SM Page 3 of 3 H:U13-001 Integra Telecom\L13-001 Integra Telecom NOD.doc 02/19/2013 February 19, 2013 City of Tukwila Department of Community Development MEMORANDUM Jim Haggerton, Mayor Jack Pace, Director TO: Jack Pace, Director, Department of Community Development FROM: Stacy MacGregor, Assistant Planner RE: L13-001, Special Permission, Director, Request for Sensitive Area Ordinance Deviation to allow permanent utility equipment in the Southgate Creek buffer and a Class III wetland buffer Integra Telecom is proposing to install fiber optic utility service within the City of Tukwila. The portion of the underground installation proposed along 133rd Street will be within critical area buffers. Temporary impacts within these buffers include a 25 square foot area for placement of a temporary bore pit and a permanent "hand hole" for utility access. Integra Telecom has applied for a special permission decision under the Sensitive Area Ordinance to do work within wetland buffers at the following two locations: 1. At the southbound on ramp to SR599 within a category III wetland buffer 2. At the northeastern corner formed by the intersection of S133 St and S 1315` Place within a Category IV wetland buffer and within the Southgate Creek stream buffer. SEPA The SEPA official has determined that the project is categorically exempt under WAC 198-11-800 Categorical Exemptions: (23) Utilities. The utility -related actions listed below shall be exempt, except for installation, construction, or alteration on lands covered by water. The exemption includes installation and construction, relocation when required by other governmental bodies, repair, replacement, maintenance, operation or alteration that does not change the action from an exempt class. (a) All communications lines, including cable TV, but not including communication towers or relay stations. BACKGROUND Integra Telecom is proposing to install fiber optic line underground along public right of way from Interurban Avenue at South 133rd Street to South 131st Place and overhead from South 131St Place to South 120t1i Street within the City of Tukwila. The underground portion occurs within two sensitive area wetland buffers and a sensitive area stream buffer; the cabling will be installed using underground boring techniques to minimize permanent and temporary impacts to the buffers. A 25 foot square temporary bore pit is proposed on the north side of 133rd Street at the highway ramp. This bore pit is within a category III wetland buffer and will be located between the street curb and an eexisting fire hydrant. The area currently consists of mown grass; the applicant has proposed returning it to its preexisting condition. A "hand hole" (a permanent 5' x 5'access panel) will be located on the north side of South 133rd Street at 13151 Place. This location is within a category IV wetland buffer and the Southgate Creek stream buffer and between an existing chain link fence and the unimproved road shoulder. The area current consists of mown reed canary grass, an invasive wetland plant. SM Page l of 4 H:\L13-001 Integra Telecom \L13-001 Integra Telecom SR.doc 02/19/2013 i00 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 DECISION CRITERIA Section18.45.030 (C) of the Tukwila Municipal Code (TMC) states that "The City shall not approve any permit or otherwise issue any authorization to alter the condition of sensitive area land, water or vegetation or to construct or alter any structure or improvement in, over, or on a sensitive area or its buffer, without first ensuring compliance with the requirements of TMC Chapter 18.45." Compliance requires evaluation of the construction as a permitted use subject to administrative review and approval by the Director according to the following criteria of TMC 18.45.070 (5). TMC 18.45.070 (5) Essential Utilities a. Essential utilities must be constructed to minimize, or where possible avoid, disturbance of the sensitive area and its buffer. The location of the utilities is based on preexisting conditions and linkages to existing infrastructure. Routing the fiber cabling along the south side of the street would not remove it out of the sensitive areas buffers. The permanent construction impacts have been minimized by proposing underground boring rather than open trenching. b. All construction must be designed to protect the sensitive area and its buffer against erosion, uncontrolled storm water, restriction of groundwater, movement, slides, pollution, habitat disturbance, any loss of flood carrying capacity and storage capacity, and excavation or fill detrimental to the environment. Best Management Practices must be followed to ensure that no construction debris enters the storm drainage system. All impacts related to construction debris will be mitigated as part of the construction permit and subject to erosion control conditions detailed by the public works department. The temporary impacts can be minimized by ensuring that no construction vehicles or worker vehicles park within the sensitive areas and their buffers and the only equipment used within the sensitive areas are the minimum necessary to complete the work. c. Upon completion of installation of essential utilities, sensitive area and their buffers must be restored to pre - project configuration, replanted as required an provided with maintenance care until newly planted vegetation is established. In addition, mitigation to offset impacts to sensitive areas or their buffers must be carried out in accordance with the standards and mitigation ratios of this chapter. The temporary bore pit area adjacent to the SR 599 on ramp shall be reseeded with a native grass seed mix. The permanent "hand hole" installation can be mitigated with the planting of 10 2 -gallon red osier dogwood along the Southgate Creek stream edge. d. All crossings must be designed for shared facilities 1 order to minimize adverse impacts and reduce the number of crossings. The will be no new crossings or changes to existing crossings. TMC 18.45.090 (C) states that "applicants shall demonstrate that reasonable efforts have been examined with the intent to avoid and minimize impacts to wetlands and wetland buffers." The applicant has designed the project to minimize impacts to the buffers. The project occurs entirely within existing roadways and roadway edges and utility corridors. Underground boring is proposed to minimize temporary and long-term construction impacts. Replace planting of native grass mix and mitigation planting of native shrubs along the creek are included. TMC 18.45.090 (E3) states that "Maintenance and monitoring of mitigation shall be done by the property owner for a period of no less than five years and for ten years when the mitigation plan includes establishing forested wetland and/or buffers. Maintenance shall be carried out in accordance with the approved mitigation plan. SM Page 2 of 4 02/19/2013 H:\L13-001 Integra Telecom\L13-001 Integra Telecom SR.doc Monitoring reports must be submitted to the City for review with the fregw.,,icy specified in the approved mitigation plan." A monitoring program shall include annual monitoring and replacement planting of any plants that have failed to thrive. COMMENTS A Notice of Application was mailed on February 5, 2013 to the applicant and to departments and agencies with jurisdiction pursuant to TMC 18.104.090. No comments were received. CONCLUSIONS 1) Installation of the fiber optic cabling is permitted use subject to administrative review and approval per TMC 18.45.070 (5). 2) The scale of the project and the resultant nominal increase in impervious area should not restrict the natural movement of groundwater beyond the restrictions to ground water already in place due to preexisting development and public streets. The project is subject to Best Management Practices for erosion control. Parking should not be permitted within the sensitive area buffers, including along the street, other than the minimal equipment necessary to bore for the cabling. 3) Mitigation will be required. Any site disturbance at the SR 599 on ramp location will be reseeded. The permanent "hand hole" will be mitigated with planting of native plants along the creek edge. 4) There are no changes to existing stream crossings. 5) The impacts to the buffer, consisting of fiber optic cable and an access vault along an existing street and utility route, are kept to an absolute minimum. 6) Long-term monitoring will be required. RECOMMENDATION Staff recommends approval of the Special Permission permit with the following condition: 1. No vehicle parking, including parking on paved areas, is allowed in sensitive steam and wetlands and their buffers. The "no parking" areas are generally along South 133rd Street from SR 599 through South 131st Place and are shown on the map included as Attachment A and highlighted in blue, green and purple -gray. 2. The area adjacent to the SR 599 on ramp shall be reseeded with a native grass seed mix. 3. The permanent "hand hole" installation shall be mitigated with the planting of 10 2 -gallon red osier dogwood along the Southgate Creek stream edge. A three foot planting area around each plant shall be grubbed out to remove the reed canary grass root system. The area should not be mulched. 4. Integra shall perform an annual inspection and provide an annual monitoring report of the plantings along Southgate Creek. The monitoring report shall note if any mitigation plantings have failed to thrive. Any plants that are not thriving shall be replanted under the same guidelines of this mitigation requirement. Monitoring shall continue until each original and any replacement plants have survived for three consecutive years. cc: King County Assessor's Office, Christie.Most@kingcounty.gov Joanna Spencer, City of Tukwila Joanna.Spencer@TukwilaWA.gov File L13-001 SM Page 3 of 4 02/19/2013 H:\L13-001 Integra Telecom\L13-001 Integra Telecom SR.doc Attachment A: NO PARKING AREAS No parking, including parking on pavement, shall occur in areas highlighted blue, green or purple -gray. SM Page 4 of 4 HAL13-001 Integra Telecom \L13-001 Integra Telecom SR.doc 02/19/2013 City of Tukwila Department of Community Development Sent via email to eric.clyaton@integratelecom.com No hard copy to follow January 31, 2013 Eric Clayton Integra Telecom 700SW39tSt Renton, WA 98057 Jim Haggerton, Mayor NOTICE OF COMPLETE APPLICATION RE: Special Permission -Director L13-001, PL13-001, PW12-088 Dear Mr., Clayton, Jack Pace, Director Your application, submitted on January 10, 2013 for Special Permission -Director is considered complete on January 31, 2013 for the purposes of meeting state mandated time requirements. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information if, in our estimation, such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. As the next step, the City will send notice of application to all agencies with jurisdiction and identified parties. A public comment period will extend for 14 days from the date of this notice. The Notice of Application is scheduled to go out in tomorrow's mail so the comment period will continue until February 15, 2013. A decision will be available after the comment period expires. Work on your project under PW permit PW 12-088 has been approved by the planning department for the work outside of the wetland area. This notice of complete application applies only to the permit identified above. It is your responsibility to apply for and obtain all necessary permits issued by other agencies. Other city departments may have other conditions. I will be contacting you soon to discuss this project. If you wish to speak to me sooner, feel free to call me at (206) 431-7166. Sincerely, (on file) Stacy MacGregor Assistant Planner SM H:\L13-001 Integra Telecom\NOC.doc Page 1 of 1 02/14/2013 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 0/5'f9 1,6-/C0 HABITAT TECHNOLOGIES March 20, 2014 Integra Telecom @ Mr. Eric Clayton — Senior OSP Engineer 700 SW 39th Street Suite 200 Renton, Washington 98057 RE: Interurban Ave & 133rd Street to S 120th Street Fiber Optic Line Installation, City of Tukwila Dear Mr. Clayton, Pursuant to the SEPA Determination for City of Tukwila project file number L13-001 the following actions have been completed. 1. Ten (10) 2 -gallon red osier dogwood (Cornus stolonifera) has been planted along the edge of Southgate Creek. These plants were located approximately mid -slope along this ditched stream to allow for suitable hydrology patterns and to allow for the shrubs to eventually overhang the stream corridor. 2. As a part of the planting of these red osier dogwoods the planting area was cleared of blackberries (Rubus spp.). Reed canarygrass (Phalaris arundinacea) was also removed from the area around the red osier dogwoods. With the completion of these implementation actions the following performance maintenance program should be undertaken to meet the requirements of the SEPA Determination. 1. Monitor the survival and establishment of the installed red osier dogwood for a minimum of three growing seasons following initial installation. Monitoring may be extended to meet the performance criterion. Performance Criterion #1: As defined by annual plant counts 100% of the initially installed or supplementally installed red osier dogwood shrubs shall exhibit survival for three consecutive years. 2. Provide the City with annual monitoring reports documenting plant survival establishment, along with any supplemental actions. Each report shall also include photo documentation of the restored stream edge area. MONITORING YEAR PLANT COMMUNITY MONITORING SUBMITTAL OF MONITORING REPORT YEAR -1 on or about Sept. 15, 2014 report due Oct. 7, 2014 YEAR -2 on or about Sept. 15, 2015 report due Oct. 7, 2015 YEAR -3 on or about Sept. 15, 2016 report due Oct. 7, 2016 wetlands, streams, fisheries, wildlife — mitigation and permitting solutions 12057 P.O. Box 1088, Puyallup, Washington 98371 253-845-5119 habitattech@gwestoffice.net 3. As a part of the annual monitoring review invasive shrubs should be removed from the streamside planting area and reed canarygrass should be cleared from around each of the red osier dogwoods. 4. Replant (if needed) to meet the performance criteria prior to the start of the next growing season following the onsite monitoring. Thank you for allowing Habitat Technologies the opportunity to assist with your project. Please contact us at 253-845-5119 with any questions or need for additional assistance. Sincerely, Bryan W. Peck Wetland Biologist 7howtas D Dewr[hg Thomas D. Deming, PWS Habitat Technologies 2 12057 The red osier dogwood shrubs were placed approximately mid -slope along this ditched stream to allow for suitable hydrology patterns and to allow for the shrubs to eventually overhang the stream corridor. 3 12057 HABITAT TECHNOLOGIES January 9, 2013 Integra Telecom @ Mr. Eric Clayton — Senior OSP Engineer 700 SW 39th Street Suite 200 Renton, Washington 98057 RE: Interurban Ave & 133rd Street to S 120th Street Fiber Optic Line Installation, City of Tukwila, King County, Washington Dear Mr. Clayton, As identified in the conference call earlier today with Ms. Jamie Reavis, City of Tukwila Assistant Planner, the City will require a short response to the City of Tukwila Municipal Code Section 18.45.090C Mitigation Sequencing for proposed installation actions located within the critical area buffers along the proposed fiber optic utility corridor. As such, the following provides an outline of the specific elements required by 18.45.090C. 1. Avoiding the impact altogether by not taking a certain action or parts of an action; Discussion: The installation of the of the fiber optic line utility service is required to meet the increased public demand within the City of Tukwila and adjacent areas. The design of the project has avoided any permanent impacts associated with the critical area or critical area buffers identified along the utility corridor. In particular, the majority of the fiber optic line shall be installed using underground boring techniques rather than open trench to avoid permanent and the majority of temporary impacts. Temporary project related impacts shall be limited to only 25 square feet for the unavoidable placement of a temporary bore pit. 2. Minimizing wetland and wetland buffer impacts by limiting the degree or magnitude of the action and its implementation, by using appropriate technology, or by taking affirmative steps to avoid or reduce impacts; Discussion: The design of the fiber optic utility line installation has avoided and minimized unavoidable project related impacts to the associated critical area buffers by limiting all actions to within identified existing, established and managed public roadway and utility corridors. Furthermore, the installation of the fiber optic line will utilize underground boring methods along the entire length of the critical area buffers. Temporary project related impacts shall be limited to only 25 square feet for the unavoidable placement of a temporary bore pit. Following the installation of the fiber optic utility line the temporary impact shall be restored to the existing site conditions. wetlands, streams, fisheries, wildlife — mitigation and permitting solutions 12057 P.O. Box 1088, Puyallup, Washington 98371 voice 253-845-5119 fax 253-841-1942 habitattech@gwestoffice.net 3. Rectifying the impact by repairing, rehabilitating or restoring the affected environment; The present condition of the critical area buffers within the limits of the identified fiber optic utility line corridor has been created and managed as a part of the development of public roadways and public utilities. These buffer areas are regularly managed and dominated by a mowed lawn plant community. Unavoidable, temporary project related impacts within the critical area buffer shall be limited to 25 square feet. Following the installation of the fiber optic utility line the temporary impact area shall be restored to the pre -project conditions to ensure protection of local water quality and to protect against adverse erosion. 4. Reducing or eliminating the impact over time by preservation and maintenance operations during the life of the action; Following the installation of the fiber optic utility the temporary impact area associated with the temporary bore pit shall be re -filled and restored/re-seeded to ensure protection of local water quality, to protect against adverse erosion, and to match pre - project site conditions. 5. Compensating for the impact by replacing, enhancing, or providing substitute resources or environments; and/or No permanent impacts are proposed for the installation of the fiber optic utility line. The minimal, unavoidable temporary impacts associated with the bore -pit shall be restored following installation to ensure protection of local water quality, to protect against adverse erosion, and to match pre -project site conditions.. 6. Monitoring the impact and taking appropriate corrective measures. The onsite construction crews shall implement routine erosion control actions during installation and undertake appropriate corrective measures if required. The project has not identified any Tong -term impacts to critical areas or critical area buffers. Thank you for allowing Habitat Technologies the opportunity to assist with your project. Please contact us at 253-845-5119 with any questions or need for additional assistance. Sincerely, -Mows D. Den/tine Bryan W. Peck Thomas D. Deming Wetland Biologist Professional Wetland Scientist 2 12026 Cita o f J um& Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, _Teri Svedahl , HEREBY DECLARE THAT: Mailer's 4 �% xeieL,. ___,_ x Notice of Application Notice of Decision Notice of Public Hearing Notice of Public Meeting Determination of Non- Significance Mitigated Determination of Non - Significance Determination of Significance & Scoping Notice Short Subdivision Agenda Notice of Application for Shoreline Mgmt Permit Shoreline Mgmt Permit Board of Appeals Agenda Packet Board of Adjustment Agenda Packet Official Notice Notice of Action Other: Was mailed to each of the addresses listed/attached on this _1st day of _February , 2012 Project Name: Integra Telecom - Fiber Optic Line Installation- Interurban Av S & S 133rd Street To S 120th St Project Number: PL13-001 Associated File Number (s): L13-001 Mailing requested by: StacycGregor Mailer's 4 �% xeieL,. ___,_ signature: i� W:\USERS\TERI\TEMPLATES-FORMS\AFFIDAVIT OF DISTRIBUTION.DOC St City of Tukwila Notice of Application Special Permission from the Director to work with Sensitive Area Buffers 4 ♦ / h. its \♦ Project Location t •s13Utst " reran,n '✓4, 4. 49 ' , S 1331d S 135th St 51370 St fey oste til � 5 139m Si Location: City Right Of Way Project Name: Integra Telecom File#: L13-001. PW12-088 Project Planner: Stacy MacGregor Applicant: Eric Clayton, Integra Telecom Project Description: Integra Telecom is proposing to install fiber optic utility service within the City of Tukwila. A portion of the underground utility corridor will be under- ground within critical area buffers. The application proposes temporary impacts within these a 25 square foot area for place- ment of a temporary bore pit. The site will be restored to preexisting conditions. _ .,mments and Appeals: The application is available for review at the city of Tukwila, Depart- ment of Community Developemnt (DCD), located at 6300 Southcenter Blvd #100. Your written comments on the project are requested and can be delivered to DCD, 6300 Southcenter Blvd, Suite #100 or via email to Stacy.MacGregor@TukwilaWA.gov. Comments must be received by 5pm, February 15, 2013. You may request a copy of any decision, information on hearings, and your appeal rights by calling 206-433-7166. b r. err City of Tukwila Notice of Application Special Permission from the Director to work with Sensitive Area Buffers ♦ • Project Location \ 5131st St 5,33td S S134:5 St 4'135.5 5' 1570 St v Foster \ ettowtootthal 's too eta' S t370S= .�• 5135th St Location: City Right Of Way Project Name: Integra Telecom File#: L13-001. PW12-088 Project Planner: Stacy MacGregor Applicant: Eric Clayton, Integra Telecom Project Description: Integra Telecom is proposing to install fiber optic utility service within the City of Tukwila. A portion of the underground utility corridor will be under- ground within critical area buffers. The application proposes temporary impacts within these a 25 square foot area for place- ment of a temporary bore pit. The site will be restored to preexisting conditions. Comments and Appeals: The application is available for review at the city of Tukwila, Depart- ment of Community Developemnt (DCD), located at 6300 Southcenter Blvd #100. Your written comments on the project are requested and can be delivered to DCD, 6300 Southcenter Blvd, Suite #100 or via email to Stacy.MacGregor@TukwilaWA.gov. Comments must be received by 5pm, February 15, 2013. You may request a copy of any decision, information on hearings, and your appeal rights by calling 206-433-7166. St City of Tukwila Notice of Application Special Permission from the Director to work with Sensitive Area Buffers y � w • ,Project Location v, s,3,st5t l,mo..` x cw.cm _p`\ Location: City Right Of Way Project Name: Integra Telecom File#: L13-001. PW12-088 Project Planner: Stacy MacGregor � q �, T` Applicant: Eric Clayton, Integra Telecom S133rti S. • h� Project Description: Integra Telecom is proposing to install fiber optic utility service g rst within the City of Tukwila. A portion of the d 6yy. Poster ; <\ underground utility corridor will be under - Z s,P '` .. ground within critical area buffers. The 3rtn st t�'t s tixn5t coo f. • within these a 25 square foot area for place- ment of a temporary bore pit. The site will application proposes temporary impacts be restored to preexisting conditions. Comments and Appeals: The application is available for review at the city of Tukwila, Depart- ment of Community Developemnt (DCD), located at 6300 Southcenter Blvd #100. Your written comments on the project are requested and can be delivered to DCD, 6300 Southcenter Blvd, Suite #100 or via email to Stacy.MacGregor@TukwilaWA.gov. Comments must be received by 5pm, February 15, 2013. You may request a copy of any decision, information on hearings, and your appeal rights by calling 206-433-7166. City of Tukwila Notice of Application Special Permission from the Director to work with Sensitive Area Buffers \\ + fit„\v�`S .. Project Location W+e.313hbnt St 44).4 4). g/ \'1". ; S1331d S. .r vry Location: City Right Of Way Project Name: Integra Telecom File#: L13-001. PW12-088 Project Planner: Stacy MacGregor Applicant: Eric Clayton, Integra Telecom Project Description: Integra Telecom is proposing to install fiber optic utility service 71. ++ under - within the City of Tukwila. A portion of the underground utility corridor will be ground within critical area buffers. The S1Nm5t ffn application proposes temporary impacts within these a 25 square foot area for place- ;, s,,,,,= 4>;yY A 3SmSt;=;t ment of a temporary bore pit. The site will be restored to preexisting conditions. Comments and Appeals: The application is available for review at the city of Tukwila, Depart- ment of Community Developemnt (DCD), located at 6300 Southcenter Blvd #100. Your written comments on the project are requested and can be delivered to DCD, 6300 Southcenter Blvd, Suite #100 or via email to Stacy.MacGregor@TukwilaWA.gov. Comments must be received by 5pm, February 15, 2013. You may request a copy of any decision, information on hearings, and your appeal rights by calling 206-433-7166. S13S;5•St Foster City of Tukwila Department of Community Development 6300 Southcenter Blvd., Ste 100 Tukwila, WA. 98188 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Ste 100 Tukwila, WA. 98188 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Ste 100 Tukwila, WA. 98188 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Ste 100 Tukwila, WA. 98188 WSDOT NW REGION KC DEV & ENVIRON SERVICES KC METRO TRANSIT/SEPA OFFICIAL QWEST COMMUNICATIONS SEATTLE CITY LIGHT PUGET SOUND ENERGY COMCAST ERIC CLAYTON UNTffl DEVELOPMENT SERVICES SEPA INFO CENTER ENVIRONMENTAL PLANNING ENVIRONMENT & SAFETY DIV INTEGRA TELECOM PO BOX 330310, MS 240 900 OAKSDALE AVE SW 201 S JACKSON ST., MS KSC-TR-0431 23315 66th AVE S PO BOX 34023 PO BOX 90868 12645 STONE AVE N 700 SW 39 ST, STE 200 SEATTLE WA RENTON WA SEATTLE WA KENT WA SEATTLE WA BELLEVUE WA SEATTLE WA RENTON WA 98133 98055 98104 98032 98124 98009 98133 98057 ( ) US Corps of Engineers ( ) Federal HWY Admin ( ) Federal Transit Admin, Region 10 ( ) Dept of Fish & Wildlife Section 1 FEDERAL AGENCIES ( ) US Environmental Protection Agency (E.P.A.) ( ) US Dept of HUD ( ) National Marine Fisheries Service Section 2 ( ) Office of Archaeology ( _3 an'sportation Department (WSDOT NW) ( )) Dept of Natural Resources ( ) Office of the Governor ( ) WA State Community Development ( ) WA Fisheries & Wildlife, MillCreek Office ( ) WA Fisheries & Wildlife, Larry Fisher, 1775 12th Ave NW Ste 201, Issaquah WA 98027 WASHINGTON STATE AGENCIES ( ) Dept of Social & Health Services ( ) Dept of Ecology NW Regional Office, Shoreland Div. SHORELINE NOD REQUIRES RETURN RECEIPT ( ) Dept of Ecology, SEPA **Send Electronically ( ) Office of Attorney General ( ) Office of Hearing Examiner ( ) KC Boundary Review Board ( ) Fire District # 11 ( ) Fire District # 2 ( ) KC Wastewater Treatment Div ( ) KC Dept of Parks & Recreation ( ) KC Assessor's Office Section 3 KING COUNTY AGENCIES ( ) Health Department ( ) Port of Seattle PIC. CDey & Enviro Services-SEPA Info Center -KC Metro Transit Div-SEPA Official, Environmental Planning ( ) KC Dept of Natural Resources ( ) KC Dept of Natural Resources, Andy Levesque ( ) KC Public Library System ( ) Foster Library ( ) Renton Library ( ) Kent Library ( ) Seattle Library Section 4 SCHOOLS/LIBRARIES ( ) Westfield Mall Library ( ) Tukwila School District ( ) Highline School District ( ) Seattle School District ( ) Renton School District zQWEST Communications � e the City Light 'van n Sound Energy ( ) Highline Water District ( ) Seattle Planning &Dev/Water Dept Comcast Section 5 UTILITIES ( ) BP Olympic Pipeline ( ) Val-Vue Sewer District ( ) Water District # 20 ( ) Water District # 125 ( ) City of Renton Public Works ( ) Bryn Mawr-Lakeridge Sewer/Water Dist ( ) Seattle Public Utilities ( ) Allied Waste Services ( ) Tukwila City Departments ( ) Public Works ( ) Fire ( ) Police ( ) Finance ( ) Planning ( ) Building ( ) Parks & Rec ( ) Mayor ( ) City Clerk Section 6 CITY AGENCIES ( ) Kent Planning Dept ( ) Renton Planning Dept ( ) City of SeaTac ( ) City of Burien ( ) City of Seattle ( ) Strategic Planning *Notice of all Seattle Related Projects ( ) Puget Sound Regional Council ( ) SW KC Chamber of Commerce ( ) Muckleshoot Indian Tribe * ( ) Cultural Resources ( ) Fisheries Program ( ) Wildlife Program ( ) Duwamish Indian Tribe * Section 7 OTHER LOCAL AGENCIES ( ) Puget Sound Clean Air Agency ( ) Sound Transit/SEPA ( ) Duwamish River Clean Up Coalition * ( ) Washington Environmental Council ( ) People for Puget Sound * ( ) Futurewise * send notice of all applications on Green/Duwamish River ( ) Seattle Times ( ) South County Journal Section 8 MEDIA ( ) Highline Times ( ) City of Tukwila Website P:Admin\Admin Forms\Agency Checklist t3 - L6\1 -41' c. Y\Ntil 335 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planninQ@TukwilaWA.gov SPECIAL PERMISSION - DIRECTOR APPLICATION FOR STAFF USE ONLY Permits Plus Type: P -SP Planner: File Number: LAS --00 ( Application Complete Date: Project File Number: --p1 i `I - l — i C 3 PROPOSED AERIAL FIBER 2 j L t sa ) St PROPOSED UNDERGROUND FIBER VICINITY & FIBER ROUTE MAP NTS CONTRACTOR NORTHSKY COMMUNICATIONS 11818 SE MILL PLAIN BLVD, SUITE #140 VANCOUVER, WA 98684 PHONE: 360-254-6290 CONTACT: RICK PETERS PHONE: 425-754-8134 EMERGENCY CONTACT: DALE KINSEY PHONE: 503-209-2457 SHEET INDEX DWG NAME 1 TITLE 2 UG PLANT 3 UG PLANT 4 UG PLANT (PROFILE) 5 AERIAL PLAN 6 AERIAL PLAN 7 AERIAL PLAN 8 AERIAL PLAN 9 DETAILS 10 DETAILS 11 DETAILS 12 DETAILS 13 DETAILS 14 DETAILS 15 DETAILS 16 RIGHT-OF-WAY 17 TRAFFIC CONTROL 18 TRAFFIC CONTROL 19 TRAFFIC CONTROL 20 TRAFFIC CONTROL 21 TRAFFIC CONTROL CALL 811 UTILITY LOCATES BEFORE YOU DIG SHT OF 1 OF 20 2 OF 20 3 OF 20 40F20 5 OF 20 6OF20 7 OF 20 8 OF 20 9 OF 20 10 OF 20 11 OF 20 12 OF 20 13 OF 20 14 OF 20 15 OF 20 16 OF 20 17 OF 20 18 OF 20 19 OF 20 20 OF 20 "74 tegra TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A QUANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INTE` 1 AVE S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: RECEIVE DEC 2 8 2012 TUKWILA PUBLIC WOR D SHEET TITLE TITLE Ks CORRECTION LTR# 1 X13-00/ Ti#01a•-Ogg • -//' '\, .// \/ O, //,/ ,� /'' 0 0�,� oc)") 7- 0,8 - / .H 4'x4' BORE PIT INT GRA VAULT 18"SD TRAFFIC CONTROL HH (2) S INTERCEPT EXISTING CONDUIT. PL 264TA HH INTERSET 2tegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. 44, PIER 18" CULVERT �y0 G, PIE PI HYDRANT,, • PIE 2+36 PL 25TA HH ss,( SIGN 4c PIE CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 ENGI BORE (2) 4" HDPE PULL FOC96F NON -ARMORED (4) 1" INTERDUCTS EACH 4'x4' BORE PIT; FULL LANE WIDTH PAVEMENT REPAIR 12'x6' (SEE DETAIL, SHEET 8) PL (1) 3'R 90° SWEEP "Po UTILITIES SHOWN ARE FROM AS -BLT DRAWINGS ONLY. CONTRACTOR SHALL CALL FOR LOCATES AND POTHOLE ALL UTILITY CROSSINGS PRIOR TO ACTUAL CONSTRUCTION OF PROJECT TO VERIFY DEPTHS AND LOCATION. RECEIVED DEG 282012 [UKWILA PUBLIC WORKS AREA MAP 1 1"=50' MARK ISSUE: INT `►`'_"� - E& S 133RD ST TO S 120TH ST DATE PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: TUKWILA, WA DISCRIPTION SHEET TITLE UG PLANT �. /3 -0D/ SHEET 1 OF 20 MATCH LINE - SEE SHEET 4 POLE # SCL1375951 \/\, •// REPLACE POLE, 40'-CL2 RAISE ST LT TO 24'-1” Pwr 24'-9" ST LT 22'-2" ELI 22'-2" CATV 21'-2" Telco 20'-10" CATV 20'-2" oy 4'x4' BORE PI / / / / POLE # 1375864SCL 40'-3-2001 PL 1" TRIPLE EYE ANCHOR & 10M DG, L= 20' PL 6M STRAND LASH FOC96F NON -ARMORED FIBER TO NEW STRAND Pwr 24'-9" ELI 20'-2" Telco 19'-2" HH N !P N CURB/EP ATTACH TO EXISTING BRACKET (2) 4" SCH 40 PVC STUB UP 12" WITH 4" PVC CAP CURB/EP S-13 St EXISTING AERIAL POWER EXISTING GROUND 3' R, 90° PVC (TYP) O1 POLE RISER DETAIL EXISTING POLE • • O1\ BORE (2) 4" HDPE PULL FOC96F NON -ARMORED (4) 1" INTERDUCTS EACH ( 4522 UTILITIES SHOWN ARE FROM AS -BLT DRAWINGS ONLY. CONTRACTOR SHALL CALL FOR LOCATES AND POTHOLE ALL UTILITY CROSSINGS PRIOR TO ACTUAL CONSTRUCTION OF PROJECT TO VERIFY DEPTHS AND LOCATION. (Zegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 ENGINE; ;1 ; ES IN TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: RECEIVECKEDBY: DEC 2 8 2012 SHEET TITLE TUKWILA UG PLANT PUBLIC WORKS AREA MAP 1"=50' N i1\ SHEET 2 OF 20 C'/3 _0o/ b 35 35 EXISTING BRIDGES r' (REFER TO SHT 11 -1 FOR DETAILS) 30 25 20 15 10 5 0 70 - PL 25TA HH co U_ EXISTING GRADE ti T - BORE: (2) 4" HDPE (4) INTERDUCTS-EACH 0 m CO CC CC W BRIDGE FOOTINGS - J U > (2) 36" SD 12" SS 96" SS FM 20 15 10 ss 5 0 1 1 1 F 1 1 1 1 10+00 9+00 8+00 7+00 6+00 5+00 4+00 3+00 S 133RD ST BORE PROFILE 2+00 1+00 1° 0+00 EXISTING PROFILE INFORMATION SHOWN IS FROM AS -BLT DRAWINGS ONLY. CONTRACTOR SHALL CALL FOR LOCATES AND POTHOLE ALL UTILITY CROSSINGS PRIOR TO ACTUAL CONSTRUCTION OF PROJECT TO VERIFY DEPTHS AND LOCATION. RECEIVED DEG 28Z01Z TUKWILA PUBLIC WORKS -1+00 AREA MAP HORZ: 1" = 100' -7,1‘17- VERT: VERT: 1" = 10' 11 Qtegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 S C. f 1 ENGINE: `'' c. ," %q, 4 45735,0 0';cis V,' `I �SSiONAL 4 ) L 4-X/' INTER,';" & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE UG PLANT SHEET 3 OF 20 L/S-GSI n 0 POLE # SCL1375835 NT -NT -NT RAISE ST LT TO 24'-4" Pwr 27'-6" ST LT 22'-6" ELI 22'-8" CATV 21'-8" Tel 20'-7" 0 POLE # SCL1375841 NT -NT -1965 RAISE ST LT TO 22'-7" LOWER CATV TO 19'-8" LOWER TEL TO 18'-8" Pwr 25'-7" ELI 20'-11" CATV 20'-11" ST LT 20'-4" Tel 19'-8" St POLE # SCL1375948 50' -2 -NT LOWER CATV TO 19'-7" LOWER TEL TO 18'-7" OI Pwr 25'-9" Pwr OHG 24'-0" ST LT 22'-10" ELI 20'-9" CATV 20'-9" Tel 19'-7" n 0 j 52' ID L.L E IC ID 1 'U I POLE # SCL1375930 50'-2-2000 100'FSL 6' MIN FROM POLE Pwr 29'-3" ELI 22'-9" CATV 21'-9" Tel 20'-6" POLE # SCL1375839 45'-3-1968 Pwr 28'-2" ELI 21'-5" CATV 20'-5" Tel 17'-9" ( 4135 POLE # SCL1375942 NT -NT -1969 Pwr 27'-3" ELI 22'-5" CATV 21'-5" Tel 20'-9" PL 6M STRAND LASH FOC96F NON -ARMORED FIBER TO NEW STRAND, 13025 ) POLE # SCL1375941 NT -NT -NT Pwr 25'-0" ST LT 23'-6" ELI 19'-10" CATV 18'-10" Tel 17'-10" ( 13031 ( 13039 POLE # SCL1375934 NT -NT -NT PL NEW 10M DG ON EXISTING ANCHOR, L=10' Pwr 25'-9" ELI 21'-8" CATV 20'-0" Tel 18'-11" ( 13045 CURB/EP—..—"J CURB/EP POLE # SCL1375741 NT -NT -NT PL 1" TRIPLE EYE Te j ANCHOR & 10M DG, L=22' N'••1 E U CID2 POLE # SCL1375845 45' -2 -NT LOWER CATV TO 21'-8" LOWER TEL TO 20'-8" PL TRIPLE EYE ANCHOR & 10M DG, L= 20° Pwr 26'-0" ELI 22'-8" CATV 22'-6" Tel 21'-8" POLE # SCL1375926 40' -3 -NT PL NEW 6M DG P.O.A.= TO BE DETERMINED SCL REPLACING POLE X X' -X" ELI X' -X" X X' -X" POLE # SCL1375846 NT -NT -NT LOWER CATV TO 21'-2" LOWER TEL TO 20'-2" Pwr 27'-9" ELI 22'-7" CATV 22'-7" Tel 21'-2" POLE # SCL1375946 50'-2-1985 Pwr 30'-0" ELI 23'-8" CATV 22'-8" C7 0 POLE # SCL1375950 NT -NT -NT CATV LOWER TO 20'-6" Pwr 24'-10" ELI 21'-6" CATV 21'-6" C 4304 V)! Pwr 24'-3" ST LT 22'-3" ELI 20'-4" Tel 16'-3" 4310 PL 6M STRAND LAS FOC96F NON -ARMORED FIBER TO NEW STRAND POLE # SCL1375944 50' -1 -NT CATV LOWER TO 22'-6" Pwr 27'-2" ELI 23'-6" CATV 23'-6" ( 4400 POLE # SCL1375743 NT -NT -NT CATV LOWER TO 19'-9" Pwr 24'-10" ST LT 22'-7" ELI 20'-9" CATV 20'-9" ( 4446 MATCH LINE - SEE SHEET 2 RECEIVED DEC 2 8 2012 TUKWILA PUBLIC WORKS AREA MAP 1" = 100' 2egra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT �a S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE AERIAL PLAN SHEET 4 OF 20 ( 12909 ) ( 12915 ) ( 12800 ) ( 12812 ) ( 12822 ) ( 12923 ) 1 POLE # SCL1375734 50' -4 -NT LOWER CATV TO 22'-2' Pwr 28'-4" ST LT 26'-9" ELI 23'-2" CATV 23'-2" Tel 18'-11" 22 POLE # SCL1407069 NT -NT -NT PL 10M DG TO EXISTING ANCHOR, L=20' Pwr 28'-4" ST LT 27'-2" ELI 24'-0" Tel 23'-0" 33 POLE # SCL1375843 NT -NT -NT Pwr 26'-7" ST LT 25'-7" ELI -arm 21'-0" CATV -arm 21'-0" Tel -arm 20'-11" OPOLE # SCL1375838 50'-1-2010 Pwr 30'-3" ST LT 27'-3" ELI 23'-8" CATV -arm 22'-8" Tel not moved to pole MATCH LINE - SEE SHEET 6 12607 ) ( 12608 ) POLE # SCL1354523 NT -NT -NT RAISE ST LT TO 24'-6" Pwr 26'-9" ST LT 23'-10" ELI 22'-10" XO Fiber 21'-10" CATV 21'-0" POLE # SCL1354687 50'-3-1992 PL 10M DG TO EXISTING ANCHOR, L=23' Pwr 31-3" ST LT ELI XO Fiber 23'-9" CATV 23'-1" 27'-2" 24'-9" ( 12677 ) S 128th St__ CURB/EP CURB/EP POLE # SCL1375740 50'-4-1975 PL 1" TRIPLE EYE ANCHOR & 10M DG, L=15' Pwr 28'-2" ST LT 26'-0" ELI 23'-5" XO Fiber 22'-5" CATV 21'-8" PL 6M STRAND LASH FOC96F NON -ARMORED FIBER TO NEW STRAND S 130th St O C 12902 ) co • 2 ( 12910 ) co 1 WI j I o I j j v i j v POLE # SCL1375832 NT -NT -NT FIBER LOWER TO 21'-2" CATV LOWER TO 20'-2" TEL LOWER TO 18'-10" PL 1" TRIPLE EYE ANCHOR & 10M DG, L=25' Pwr 26'-3" ELI _ 22'-2" Fiber 22'-2" CATV 21'-2" Tel 19'-10" j o (13000) H RECEIVE[ DEC 228 2012 TUKWILA PUBLIC WORKS AREA MAP 1" = 100' integra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. a CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A (go UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: WG FILE: RAWN BY: CHECKED BY: SHEET TITLE AERIAL PLAN .d, SHEET 5 OF 20 Z1? -0d/ MATCH LINE - SEE SHEET 7 ( 12401 t t POLE # SCL1354562 55'-1-117-2007 Pwr 35'-1" ELI 23'-2" XO Fiber 22'-2" XO Fiber 19'-6" CATV 18'-0" POLE # SCL1354556 55'-2-1986 Pwr 30'-3" ST LT 26'-3" ELI 24'-4" XO Fiber 23'-4" XO Fiber 22'-3" CATV 21'-3" \ ( 12449 PL 6M STRAND LASH FOC96F NON -ARMORED FIBER TO NEW STRAND ( 12525 ( 12539 ( 12541 S 126th St POLE # SCL1354552 NT -NT -NT Pwr 30'-3" ST LT 26'-5" ELI 24'-9" XO Fiber 23'-10" CATV 22'-10" POLE # SCL1354690 NT -NT -NT LOWER FIBER TO 24'-11" LOWER CATV TO 23'-11" Pwr 32'-0" ST LT 27'-10" ELI 25'-9" XO Fiber 25'-9" CATV 24'-11" Tel 22'-5" ( 12601 POLE # SCL1354683 NT -NT -NT RAISE ST LT TO 24'-1" LOWER FIBER TO 21'-6" LOWER CATV TO 20'-6" Pwr 26'-0" ST LT 23'-5" ELI 22'-5" XO Fiber 22'-5" CATV 21'-6" \ POLE # SCL1354558 • NT -NT -NT \ NO CONTACT \ N \ MATCH LINE - SEE SHEET 5 POLE # SCL1354555 NT -NT -NT RAISE ST LT TO 22'-2" LOWER FIBER TO 19'-9" LOWER CATV TO 18'-9" Pwr 23'-5" ST LT 21'-5" ELI 20'-6" XO Fiber 20'-6" CATV 19'-9" RECEIVED DEC 2 8 2012 TUKWILA PUBLIC WORKS AREA MAP 1" = 100' .�: (Zegra TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INTE'I & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE AERIAL PLAN SHEET 6 OF 20 ( 12400, POLE # SCL1354893 70'-1-2000 PL 1" TRIPLE EYE ANCHOR & 10M DG, L=18' Pwr 35'-2" ELI 26'-5" Qwest 25'-5" FSL FOR\ FUTURE \ BUILD. AERIAL TERMINATES \ AT POLE 1 POLE # SCL1354569 65'-1-2001 Pwr 35'-2" ELI 26'-4" Qwest 25'-4" POLE # SCL1354567 BT -BT -BT CATV LOWER TO 21'-5" PL 10M DG TO EXISTING ANCHOR, L=6' Pwr 25'-7" ELI 22'-5" CATV 22'-5" Qwest -arm 19'-11" ( 12115 POLE # SCL1354XXX X'-X-XXXX PL 1" TRIPLE EYE ANCHOR & 10M DG, L=10' POLE # SCL1354568 65'-1-2007 PL 1" TRIPLE EYE ANCHOR & 10M DG, L=10' PL 10M DG TO EXISTING ANCHOR, L=6' Pwr 34'-10" ST LT 32'-2" ELI 29'-4" XO Fiber 28'-4" CATV 21'-7" 12200 POLE # SCL1354554 65'-1-2007 Pwr 35'-2" ELI 23'-0" XO Fiber 22'-0" CATV 20'-4" Pwr X' -X" ELI X. -X" Qwest X' -X" ( 12265 PL 6M STRAND LASH - FOC96F NON -ARMORED 1 FIBER TO NEW STRAND '1 511 r'4- i (12301) ''�^^ (12303) 1; { I. 1. 1 { \ 1 i a 1 ,....•••• .1. 1 1 'll 1 t 03 k.1. :1 I ' n V , k. POLE # SCL1354566 S 124th St 70'-1-2001 1 i POLE # SCL1354565 65'-1-2007 Pwr 35'-2" ST LT 33'-7" ELI 25'-9" XO Fiber 24'-9" CATV 20'-2" POLE # SCL1354684 65'-1-2007 Pwr 35'-2" ST LT 29'-5" ELI 24'-3" XO Fiber 23'-3" CATV 21'-7" 100' FSL 6' MIN FROM POLE MATCH LINE - SEE SHEET 6 Pwr 33'-0" ST LT 29'-8" ELI 27-0" XO Fiber 26'-0" XO Fiber 24'-5" CATV 23'-1" RECEIVED DEC 2 8 2012 TUKWILA PUBLIC WORKS AREA MAP •1% 1" = 100' (tegra! TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE AERIAL PLAN SHEET 7 OF 20 264TA HAND HOLE IN SIDEWALK a INTERCEPT EXIST.' Art". -18-1.41 TELVI' START OF PROJECT- INTERURBAN AVE & GATEWAY DR (EAST) CROSSING INTERURBAN AVE AT S 133RD ST (WEST) IRECEEVED DEC 2 8 2012 TUKWILA PUBLIC WORKS integra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 3 1 -2/42 - INT & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 8 OF 20 : 1111 . • •• :Ike T 'AS BORE PIT - SOUTH SIDE OF 133RD ST (STA. 2+36) r f\\1 South 1J33ri Sir 133RD ST (NORTH) - LOOKING EAST -0.11.,,;u111,4 25TA HAND H NORTH SIDE OF 133RD ST (STA. 2+36) BORE PIT - NORTH SIDE OF 133RD ST AT HIGHWAY RAMP DEC 282012 'Qtegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT' 4 • - t & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 9 OF 20 TUKWILA PUBLIC WORKS L./3-00/ ft\ 5 � 13-1 e S`kc S`3l \- S� HIGHWAY RAMP CROSSING - NORTH SIDE OF 133RD ST 25TA HAND HOLE NORTH SIDE OF 133RD ST T 131ST PL STA. 8+67 SEED WITH NATIVE GRASS MIX TOPSOIL - 95% COMPACTION EXISTING GROUND 3/4 " MINUS CR ROCK 95% COMPACTION BORE PIT BACK FILL DETAIL RECEIVED DEC 282012 TUKWILA PUBLIC WORKS ikgra TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY p10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 IN & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 10 OF 20 4/3-00/ BRIDGE FOOTING (TYP.) (73 BRIDGE DECK - BR. #599/5W EXIST. GROUND BRIDGE DECK - BR. #599/5E 0, PROPOSED (2) 4" FIBER CONDUIT BRIDGE FOOTING ELEV.= 8.0' BRIDGE FOOTING (TYP.) (TYP.) BRIDGE SECTION - FACING NORTH ON 133RD ST CENTERLINE 133RD ST BRIDGE DECK _J L EXIST. GROUND PROPOSED (2) 4" FIBER CONDUIT 6' MIN. FROM CENTER OF COLUMN BRIDGE SECTION - FACING EAST ON 133RD ST / RECEIVED DEC 2 8 2012 TUKWILA PUBLIC WORKS in a� tegrTELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 11 OF 20 �-/3 -00/ EXISTING GROUND (TYP.) ELEV.= 18.6' ELEV.= 11.5' BRIDGE FOOTING (TYP.) BR. #599/5W EAST FOOTING SECTION ELEV.= 8.0' ELEV.= 18.6' ELEV.= 11.3' ELEV.= 8.0' 6' TYP. ELEV.= 18.6' ELEV.= 12.4' FACE OF CURB 7 (TYP.) BR. #599/5E EAST FOOTING SECTION ELEV.= 18.6' \ ELEV.= 12.1' 00 ELEV.= 8.0' ELEV.= 8.0' BR. #599/5W CENTER FOOTING BR. #599/5E WEST FOOTING SECTION SECTION ELEV.= 18.6' \� ELEV.= 11.0' PROPOSED (2) 4" FIBER CONDUIT 6' MIN. FROM CENTER OF COLUMN (TYP.) ELEV.= 8.0' BR. #599/5W WEST FOOTING SECTION BRIDGE FOOTING SECTIONS RECEIVED DEC 282012 TUKWILA PUBLIC WORKS in tegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INTE S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 12 OF 20 L /8-00/ PAVEMENT REMOVE/REPLACE LIMITS WIDTH VARIES SAW CUT (TYP) Av 44' c'q;:,.':: ''q::: Imo. Q SEE NOTE 3 4`. : 'rtf may:-►. SEE NOTE 2 CROSS SECTION A LEGEND O EXISTING HMA (HOT MIX ASPHALT) OR PCCP (PORTLAND CEMENT CONCRETE PAVEMENT). O HMA CLASS %=INCH OR PCCP* DEPTH AND MATERIAL SHALL MATCH EXISTING PAVEMENT. REMOVAL AND REPLACEMENT LIMITS OF PAVEMENT TO BE DETERMINED AT THE TIME OF UTILITY PERMIT/FRANCHISE REVIEW. © APPROVED BACKFILL MATERIAL OR CDF (CONTROL DENSITY BACKFILL) OR AS SPECIFIED BY WSOOT. p BEDDING MATERIAL. BEDDING MATERIAL DEPTH OVER AND BENEATH PIPE CASING SHALL BE HALF THE 0 DIAMETER OF PIPE CASING OR 6 INCHES WHICHEVER 15 LESS. O EXISTING CRUSHED SURFACING BASE COURSE. F CRUSHED SURFACING BASE COURSE DEPTH SHALL MATCH DEPTH OF EXISTING CRUSHED F\EJ SURFACING BASE COURSE O HMA BUTT JOINT REOUIRES TACK. SEAL AND SAND. FOR PCCP REFER TO GENERAL NOTE 5. GENERAL NOTES I. TRENCHING AND PIPE INSTALLATION SHALL MEET THE REOUIREMENTS OF WSDOT STANDARD SPECIFICATION 7-08 EDGE OF PAVEMENT I 1 1 1 EDGE OF LANE SAIWCUT ` 1 EDGE OF TRENCH —On r - EDGE OF TRENCH SAWCUT EDGE OF LANE EDGE OF PAVEMENTI J TRENCH PLAN VIEW 2. MAXIMUM TRENCH WIDTH SHALL BE OUTSIDE CASING PIPE WIDTH PLUS ONE FOOT EITHER SIDE OF CASING PIPE. 3. COMPACTION SHALL BE METHOD "C" PER SECTION 2-03.3 (14) C 4. MINIMUM DEPTH SHALL BE 60 INCHES FROM THE FINISHED SURFACE TO TOP OF CASING 5. PCCP SHALL BE REPLACED TO THE NEXT PANEL JOINT IN EACH DIRECTION AS APPROVED BY WSDOT. ALL WORK SHALL BE AS SPECIFIED IN WSDOT STANDARD SPECIFICATION SECTION 5-01.3(4) 6. WHEN CONNECTING TO AN EXISTING FACILITY UNDER THE PAVEMENT. PAVEMENT RESTORATION MAY. AT THE DEPARTMENT'S DISCRETION. INCLUDE THE FULL LANE WIDTH AND ENCROACHEO SHOULDER T. CASING PIPES SHALL EXTEND A MINIMUM OF 5Ix (6) FEET BEYOND THE TOE OF FILL SLOPES. BOTTOM OF OITCHLINE. OR OUTSIDE OF CURB. 8. TACK ASPHALT PER WSOOT STANDARD SPECIFICATION 5-4.3(5)A APPUCAI1ON: APPROVALS: OPEN CUT CROSSING UTILITY TRENCH BACKFILL DETAIL /ft Washington State VI/ Department of Transportation WSDOT Utility Accommodation DRAWN BY: Lynn Waldh.r, NWR Utilities Engineer DATE: January 2010 SCALE: NTS Sheet: of: RECEIVED DEC 2 8 2012 PUBLIC WORKS Zegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INT 'I E& S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 13 OF 20 x/3--00/ 5 8r Bolt -Down Locking (2) 1/2" Dia. Hex Bol s7 2• -gr; rrr[\rirrrrrrrrr�\ir;r;rrrrr-\crr;r;rrrrr-'' -.r�rarrrrrrrr rrr rrrrrrr;ri;r:rr;r;;r:r:rrrrrr;r;r;r;r;rrr r;rrrrrrr'.rrrrrrrrr\rrrrrrrrrr,'rrrrrrrrr.'rrrrrrrrr\crrr;r;rrrrrr-'�r;rrrrrr,r�rtrrrrr;rrr,rr,r;rrrrrrrrr-,rrrrrrrrr��c,rrrrrrrrrr-rrrrrrrrrr��rrrrrrrr��'rrrr,r;trrrrrr;r;'�;rrrr;!rrrrrrYiiiirr♦rrrrr r„„;,r`rr,,,:r, .r �rr;rrr rt4-rrrrrrrr� ,rfr�rr.�.rrrrr\;<r;rr;<rrrr-: rrrrrrrrrrrr♦r rrrrrrr,;�rrrr;rr♦ ;rr,,,,,,-;;\5,-, r rrrrrrrrrrrr:rrrrrrrrrrrrrrrrrr;;rrrrrirr;rrrrrrrrr;rvr.rr,r,r � 1".„ Recessed Lift Handle PLAN VIEW 3/4"0 Insert, w/ Hex Bolt 2 Eoch Side, 2 Sides Galvanized Diamond Plate Covers w/ Bolt -Down Locking 1 1/2" Dia. Lift Hole 1 Eoch Side, 2 Sides 3i" Adjustment N 25 -TA Golvonized "C" Chonnel, 4'-0" Lg. 1 Each Side, 2 Sides QWEST PID# 2378448 Full Length 10" Wide Knockout In Floor For Intercepts SECTION AA L 3/4" Dia. Pulling Insert 1 Each End, 2 Ends SCALE: 3/4" = 1'-0" Full Length Knockout END VIEW Oldcastle Precast@ Utility Vault PO Box 588, Auburn, Washington 98071-0588 Tel: (253) 839-3500 Fax: (253) 735-4201 25 -TA File Name: 010-25TA Issue Date: 2010 www.uvauburn.com 25 -TA 1'-10" x 4'-9" x 2'-4" I.D. COMMUNICATIONS ©1970 -2010 Oldcastle Precast, Inc. 64.1 RECEIVED DEC 2 8 2012 TUILA PUBLICWORKS 'l2tegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE DETAILS SHEET 14 OF 20 PUBLIC WORKS Z/3 -ate/ • 7® tntegra • `\ *renY T. 3 NaR. 4 E. W. Ma afi10N NO. RAN ifCitK AS MAC( N0. ■asi F16 g, :: : >r � ` ` la WASH' F 5990 ) Sec.15 For rota/ Areas, Paresis (I-294 G` 'mar / '� <v �• i�`\ �hC f �\' TIPPETTS A08ETT MCCARTHY-STRATTON TELECOM CI. sea Vicinity Mop and i%to/ '..• P• 7' 17+95.2- /1b 3./3 % r\ �i N. \/\V// • /r (�\/ j , 9 Porce/ beta//, Sheet No. /. ' . 4 "'• / / .'• ���:,��.-,H•� 'ENGINEERS AND ARCHITECT; . y'�/ 41.65 / �� _. r.••• \ Pe ' \NEW YORK SEATTLE ACCESJ NOTE: trt • S•`r I Q� , ��e 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 G The City of Tukwi/e wi//be permitted to moinfvin P ® 0 sanitary sewtr and /ift station located within V the right of way from the right of Relocated So. n 4 ti, ts G. 133rd St. at Stb.2/fi80 in xcordonn wifh provisions 1D 4s c\ ��•� O of Permit No. Northrup /866, Revised. �, * 00 5+,0 4 (`�" /��\ ` j \` 134 ,1".e. f^ ��� �� tic\\fir 0 i�� ��� �/Cj� n ig d� e b • 2 R �. Yt!►� s J. � /../ `• •� A11P0..en. , d e g• G;7 � 0 :t '� R or-, * am; \ . . ejhar "44-4.":04 `?`22...... ` t ® `aa+ j% " +'a. 7 R ■Mp"r' aT!w a �•, t f.- "T 6.044_ b u'rme %'•.1 r ti �• *L. tr ,�( �" '�••YMt a, w", ` • �ZRR "/�' �` •. hOtare ��co THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. ♦R ti F .meq s. 5‘.; lee, 1 I F h p V 11 ` I 1 U ,- i 1. + I I 0 1 ' ^N ,el. \� ,r �y n ti■ \ • v a • Qa `rC \ < 0' ry° �'i� _-� \ q, �/ • of as % /� + 11ti � :, `, �� _ 4T v' / • "(. Ji i >f�--�- •mss s ry�3,:• r y r•. �' \r�'' (jf3i1► • 1<. �; j r �'"=' :._ s �.#' °'= 4."4$s �e � avo,,v,,-- ,rr-1"T. +T7♦ivat A ' •-Ff 22 / ' / yF� N I ,..„,./ 1 2\� 1 I� I t U C A HAN� L * ,- �. 3*a�r l \ . ++a' 10 l :2 I► ""s� A1iJZP:.ggK " ,-+=,'� I` 1 !�. . R I r . -,4 ds./ , Q DAMAGE CLAIM 1?� — `p.�' "`1 1 eg,11. 1j L1I111IT3 :r �_jzoiiI'FjS .e [ fix 10 +� l(li ' ,'... i�yi�/ l �• %i / \ PARcet NAME NO, I CONSULTANTS <"1,...-9› V•oj © 1 i I C PORA7B I % A, 12e off_` �',�- rl-�j ���YC", 1-2953 JOHNSON Itl TIN 1 TU o p 111 ►} _--- •20• la\_---_-_-`— .-=_'-._ 11 10. ' 77.5i' IIA, 11 ¢l _ III , t 1��, --1==-7-7_-_,-.7-- QT------7:::41 ."11 ` lid 0 �'-�-� 'and L/A book ass SRS �1 r ��� -•- to So. /713th. z* T l l _e . 1 .4 \\ 'fid i st. Sheet 9E/0 y it 11� 1 T+.._ ste opproved iR �fi� e� /9G2 ° yam/ fl�� lb r iA ► ti�w v'(•!'i�f. h ��lq •'� qy (((f�•,a� +1r 86� LIQ ia \ , • "�•'+ IIII , Jo 0 ,7 {78 � d�-K' F` ;'�+ u �--' .zi* �� ((� '�a'i`-' •�� �� �D li ,� .a • ��` is N 'liffeefv.,, ,"�" f •- • `♦I tV / �` 4..E599.9 St4i39G o; re�■ �►- -...S.1 i• �. u + * u1 •'� • �� 1 7 ` S _� e:; ,. 2 *77 / ` I1 *� R --_- X590.96'.. , 0. Gat s ` C I1✓y:■f 4' 6V • �T -� i 1 ^I (o •-- �4• !3 Chick. No. q /4 `�i �'.: o �% 6 11 a 92 * f. ick.No* 9 s� . % ott �'�',f•0*' �, sl,, ''e � �j� ti �lf'� � �I l50" • ;9 .-•562. `'�R£UN, =ON `. Y ` C' a Vim-+ a I",� '' : �• , l" S' _ o �' n, L-DC- l Q• 6 C �� 0 utt CU Sr1 ey n aT t �! *—Z31 15 �w ! , �' O ,(�?r� p� !m -• WAIN (t ACCESS NOTE: �.� ''�-'� : .- =_ `f¢ - ' a �ai Pedeatriom arsd Stcycle AC.esa 7 (g w :r.w ', , `. Will be. Permitted to Interurb■.n ....� W# = E O • QY�►w1► Ave. Cram cto IT,,00 to .to. t55.,0 .v� �" """ * �>, rs 1G ■ 1 ENGINEERING ASSOCIATES, INC. Communications Engineers A QUANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 / _ C. fl ENGI �F_ • .. •q� l) /N , G '�� /p �r�J '' a✓! �•y '. � 45135 w �! `n 4 `(i!5I1:i` �-(<18L aft ,i, :�` Y.+ll . �( {I♦■ on the Right. �r Q4 d f 4;, •,� , f JG• !�rl''•t i l i'_ .a - _AY, \^�_ 1,.•� _ i�L'�E1.�� r� \t SG4TTLE -914 �' 4303) Ir !,a 00 ` 1 40 i�i�M '� .....0%. n _ - — z Yr =;, 5 -' 1g7�11����tre 1IIr� j 9 Od �r. f6 LINE � ra�? X17 ) X0'-_ - i2 ACCESS NOTE: �1`��omow•®4a i 40 ••�����i )ATION ��� - No.21. The privilege of servicing the uftlity /.<Sk.�F-3/+SJ./Ah. � ;�-,_`✓IYF�'-1� � �� �� ' . 13��•+� O 11i' / tea ' •1gs' - co JO*T306ke/45 3 / 4 I�'sr �•'��117tul_I 1 �/T/ X11/,4 B • T � 1+ tiWIW �O ^ � - ■ '�. sl O5 s 4,01 lL4 r•'n_ located within the right of way wi11 be t�/y� ^a r u ore' — ' ■C o. / �!''i[0301 I �; _--' permitted to the utility specified aubycck to `�Agat -4II�jt,/Y 1� n V .fi �F A V ' :: ��NN'1.'4S'E p q 1.'�• -/� the conditions of the t:rancl„Se, P¢rnut of -//,/•- •� f J ,e, =_ = ` �.�p —/ be 1 No _ s f 1 E� ! S IN - • �• S 133RD ST TO S 120TH ST TUKWILA, WA = -- - - — access will 4 t�� 1 t ® -' —, �� __ -� .� Agreement specified. II ' D ./-_----- 1► - ,,,r -'w" �.,t' rla - -- r cllowed to or from the traveled hyhway (Ones. �( / _=-• a$'3u S;oPeEasemant hway ' h\l i �' 1 ' -I I — __ /stinist. Hrg 1 t "�] shed g 11 v✓ i . fission erne _ VI c OF PLAN 2 : ` / „z, Trom . s 1 •• }. ■ - e. s z fza0.37 � .. _4444. 1 c,--.4.•• • - AIRSPACE LEASE SCHEDULE _ 3 27*00 P.O.C. 41%T!' .� ..=` �sf:TJ� ■y fn C' }}�� _ tv NUMBER LESSEE LOCATION •{: . • 7 :7l9� - ` 6 For i;><'cofionTUKWrL.. ' OJ l•05027 C1a. ktlit of WoSh. lnc FA 3to D8443 fi Ste.40+4p on l!------R , 7979AA n —�t:� fwflo by=2rx•u -- - 3/,to tivsAcfakWde�, • `T+ o4T —I'r-== �� YO Ci4yar ::41- 444. __A=•_ T`--_ ySGR.J-..am--ce9vad �1►Wit• �+ •i ir1Ca1�S•� PO.T3O..G ' a- Co� nre�, 2!, SOROAD ADPROACN 6[NE000E� .760it/OT't. 1Ci/ ppFx i•rtt �•-.- *c 1Y �,. 'v'/%�,.?'•�'.Q'3,f]-_O 5\epe E•,�SL+M` s.T.I_._.___" EP9�MF'NT V •i ..\-ad by p SPECIFIED USERSTATIDN ON ROADWAY TYPE ItaV II ;,"-y= w\\e*,T% s5 ton -NAGE -: daT`^\`opgreEl518CtaYGR I of dv6ah.Dc. FAS1L'96hbto5ta,Ot400att: AAT•OioeT•Faelane LI ,_II ,u.n■tr",et �5L•'E D 4a =ORPIT NATE: Foc ocens CORP.L\MCS pNGF / �e ____4---- �) I ,u.. A// bearings !r' distances Il �LC _ - see SR\81 �• OSZER \NTERC\1 pp _� -____ I\ ,1ia+i� I preceded by an oetieriak II 264TH HAND a __� 11t9tt1t�R� are to and p/,, troops. ll o�A Sheet F95h¢ ts,APPro ¢dMoy�5969 \h\ r/� I�• For R/W on SRIBI bock of Stn 120+00 see it �� 9� G'0 SR 5, SOUTH 118TH ST. TO SOUTH 126TH ST. 11 VbSg°�!\ VG �p /5f' 511es+ 10 of 21 %teats, Approved Jon. 30, 1962. ..,p �Q ( -NOTE: 5¢4� MARK DATE DISCRIPTION ISSUE: Wash. Sfnte Cooed/nate System. Noeth Zona o,�0 . S4 ♦ \ +.�_ Es xblisbad by Commrsaion R¢er. NO1356 WSDOTS OWNERSHIP PROJECT NO: Converted To proJeetOatum Pane *t V/CPte \° SHOULD BE NEVI,' ' --- •. - • _ 9 O' 0' �• PROPERTY/ FOSTER INTERCHANGE TO SOUTH 118TH. ST. DWG FILE: DRAWN BY: srahipe ese• Sheet Ab. 3 C U R V E DATA Adaaa a.T.a.e...rd rows vA a eer,.i.i ears xi- ta- gg,I14el KING COUNTY CHECKED BY: LESENQ • N T n D R T L G-3-87 a-s7 129.59.70 Rt.{Aaead eni p� .,'�ii.It .S9'e:a Ave. stav I 1.0o /a sent. Ava. iss.T6 Hta.., >1,9n. R LiA. i1�v a� SHEET TITLE S to be shown 1hUJ m".urrrnrrrrearrr P 1. STATION ,0 tatter 9 1e. a,a• r�,. ta. tao.ly r3Qt e s „1 1PIt Aral' aveman4 RIGHT OF WAY prohibited Ed- #40.55 �•Yx!.E dElAr-irfAriL\rb 10'-..' F11401F,141/1-IC_'5ti.I 'py ...a. vn ..a b.eyel inl,�vs- Na, as rsJ o.S. Ave., t"a,� ie„ac ,. x.,t.Avr_,�.,o_.��i.m st�a.FA2't00 to Sto.. FA 34400 'fy ownership number's 1-P U_ . '--- .,JG ��— L.44V 5-31-So 4-LS-So A4 iurnb,ce l;na4Un- eer,lfiwtion focal Vital %N1.4 is 141400 ION RIGHT OF WAY tii4[1,1k EMNE J4[ {',. ;fJ�j•Utih..S5111111111111 self 4111�.-� WIEF•IWEI LOW S•l3.Tl 4.21-31 Adiai Typs2l appwerh FASU010+49 tn5ta 4044oenLt.A4xtttfase A& -osoz, RLS WASHINGTON STAN! 111OHWAY COMMISSION 'IQ Lines �� �� is -�• -�'j 1G. 2,6579£C�MM 35=00' �eZm muffs '� Ci/rdTWtw;Y/vnliMhmaefarnpa.rwa}IiHafalwr/NSW., 2/reORR w+. 'H,/ DF/ARMWi A HNGTON3 OLYMPIA, WASHINGTON Etwar l:iil•� • -G�• ' �•�11 ee �:'�� Let4er II-28-7S 'DEGAS p.,,.1/-Nw nbrfhryo /BfC,Revigd, add T 6.k Eats Yrtrnqus3anr0 fe cify R15 lo Gorden Tracts' ® e1 a "�' ffl.,Ifk..:AIIS,1 '� .�ti'7MirkISf-�EIVPIi IrkkkM� Al team,•-LS-K 9.4.14 Adddmetsa(a•anisfwens/a niaas.cukeaSe16112e...+.lSbfao...Rt. R[3_ arMuua aaL- Replof Fostoria S Letter 44414 2-25.14 DNelad Utili4o f taro Slope SDrui ape Falunent SIM 1xltao,e 193+OD ow R+. RLS ' ► I. a Mut a on OF O —_ i L¢ttU 2.7412 9.8.12 ntoid proptriy conveyed t. Shaman t Y QCD T-M •12 RLS• '� rden Treats / L4atar IT•N•N `[+ ls•1 y x.18.4. cNlos paosa rta,eq In „Or, p .,,�� �r ! eu. V. tom' �1`s` T inion of Lots 7,5 09 eP / \ P, r�%zG-Wt n M r:a.) 1 "tu,ep: ,: nrb'Ti"iN/s+aii,•'",,_ :aA .•->,_ lG _. ,G-J 5445.,.. '....a .800 4,rxs dONo Carden Tract's. 6sarrng Equably for Existing S.SH.2-44 ■/'-41:45" c•sa 151 .00a.. a1 c - �Ablz +. 4 L +1 12-u-G,, 9-•9-G! t .A`a 1.29c, AW SKIT a 0/ .i sNFfis SHEET 15 OF 20 __ S6 J1;14414;�5 -1-..' .1-"31s..a...E-. aPRcvr,_ SEQUENCE 20 sR s9fx RECF1pV[ ® fFr.9A2ni? PUBLIC WORKS Z/3 -ate/ LEGEND SIGN LOCATION s e e CHANNELIZING DEVICES ARROW PANEL x G20 -2A SIGN SPACING (1) = X RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 60 / 65 MPH 45 / 55 MPH 35 / 40 MPH 25 / 30 MPH 800' ± 500' ± 350' ± 200' ± (2) 25 MPH OR LESS 100' ± (2) ALL SIGNS ARE BLACK ON ORANGE UNLESS DESIGNATED OTHERWISE 1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS, AND DRIVEWAYS. (2) THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. G20 -2A MINIMUM TAPER LENGTH = L (FEET) LANE WIDTH (FEET) 25 POSTED 30 35 SPEED 40 (MPH) 45 50 55 10 105 150 205 270 450 500 550 11 115 165 225 294 495 550 605 12 125 180 245 320 540 600 660 CHANNELIZATION DEVICE SPACING POSTED SPEED IN TAPER IN TANGENT (MPH) (FEET) (FEET) 50 / 70 40 80 35 / 45 30 60 25 / 30 20 40 GATEW AY DR X w20-1 ROAD wnak WORK AREA \ r2 / IRO0NON N� O 0 G20 -2A CLOSE DWY DIVERT TO DWY 140' EAST ( DWY NOTES 1. If the work space extends across a crosswalk, the crosswalk should be closed (see Standard Plan K-34.20). 2. The normal procedure is to close on the near side of the inter- section any lane that is not carried through the intersection. However, when this results in the closure of a right lane having significant right tuming movements, then the right lane may be restricted to right turn only, as shown. This procedure increases the through capacity by eliminating right tums from the open through lane. 3. Prohibit tums as necessary for traffic conditions. 4. Flashing Waming Lights (Type A per MUTCD) should be used, as needed, to mark barricades at night. 5. Steady Buming Waming Lights (Type C per MUTCD) shall be used to mark channetizing devices at night. 6. For long term projects, conflicting pavement markings that are no longer applicable shall be removed or obliterated. Temporary markings shall be used as necessary. 7. For signs size refer to Manual on Uniform Traffic Control Devices (MUTCD) and WSDOT Sign Fabrication Manual M55-05. RECEIVED UE(; 282012 fUKWILA PUBLIC WORKS (aegra TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE TRAFFIC CONTROL SHEET 16 OF 20 L/2 -- Co/ G20 -2A LEGEND • • o 444 W20-1 SIGN LOCATION CHANNELIZING DEVICES ARROW PANEL SIGN SPACING (1) = X RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL 8 BUSINESS DISTRICTS URBAN STREETS 60 / 65 MPH 45 / 55 MPH 35 / 40 MPH 800' ± 500' ± 350' ± 25 / 30 MPH 200' ± (2) 25 MPH OR LESS 100' ± (2) ALL SIGNS ARE BLACK ON ORANGE UNLESS DESIGNATED OTHERWISE 1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS, AND DRIVEWAYS. (2) THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. m croror R3 -7R B/W Red LAR[ MUST MIN Mid MINIMUM TAPER LENGTH = L (FEET) LANE WIDTH (FEET) 25 POSTED 30 35 SPEED 40 (MPH) 45 50 55 10 105 150 205 270 450 500 550 11 115 165 225 294 495 550 605 12 125 180 245 320 540 600 660 CHANNELIZATION DEVICE SPACING POSTED SPEED IN TAPER IN TANGENT (MPH) (FEET) (FEET) 50 / 70 40 BO 35 / 45 30 60 25 / 30 20 40 GATEWAY DR G20 -2A NOTES 1. If the work space extends across a crosswalk, the crosswalk should be dosed (see Standard Plan K-34.20). 2. The normal procedure is to close on the near side of the inter- . section any lane that is not carried through the intersection. However, when this results in the closure of a right lane having significant right tuming movements, then the right lane may be restricted to right turn only, as shown. This procedure increases the through capacity by eliminating right tums from the open through lane. 3. Prohibit tums as necessary for traffic conditions. • 4. Flashing Warning Lights (Type A per MUTCD) should be used, as needed, to mark barricades at night. 5. Steady Buming Waming Lights (Type C per MUTCD) shall be used to mark channelizing devices at night. 6. For long term projects, conflicting pavement markings that are no longer applicable shall be removed or obliterated. Temporary markings shall be used as necessary. 7. For signs size refer to Manual on Uniform Traffic Control Devices (MUTCD) and WSDOT Sign Fabrication Manual M55-05. RECEIVED DEC 282012 1Qtegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 INTEVE & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE TRAFFIC CONTROL SHEET 17 OF 20 TUKWILA PUBLIC WORKS MINIMUM TAPER LENGTH = L (FEET) LANE WIDTH (FEET) 25 POSTED 30 35 SPEED 40 (MPH) 45 50 55 10 105 150 205 270 450 500 550 11 115 165 225 294 495 550 605 12 125 180 245 320 540 600 660 CHANNELIZATION DEVICE SPACING POSTED SPEED IN TAPER IN TANGENT (MPH) (FEET) (FEET) 50 / 70 40 80 35 / 45 30 60 25 / 30 20 40 G20 -2A W20-1 0 cece SIGN SPACING (1) = X RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 60 / 65 MPH 45 / 55 MPH 35 / 40 MPH 800' t 500. ± 350' t 25 / 30 MPH 200' t (2) 25 MPH OR LESS 100* t (2) ALL SIGNS ARE BLACK ON ORANGE UNLESS DESIGNATED OTHERWISE (1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE G20 -2A RAMPS, AT -GRADE INTERSECTIONS, AND DRIVEWAYS. W20 -7B W4 -2L (2) THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. W20 -5R W20-1 W20 -7A W20 -7A W20 -7B X X X L X L X W20-1 W20 -7B LEGEND o a o SIGN LOCATION CHANNELIZING DEVICES dKA ARROW PANEL FLAGGING STATION W20 -7A X W20 -7A W20 -7B 5301 G20— 2A ENO ROAD WORK • G20 -2A NOTES 1. If the work space extends across a crosswalk, the crosswalk should be closed (see Standard Plan K-34.20). 2. The normal procedure is to close on the near side of the inter- section any lane that is not carried through the intersection. However, when this results in the closure of a right lane having significant right turning movements, then the right lane may be restricted to right tum only, as shown. This procedure increases the through capacity by eliminating right tums from the open through lane. 3. Prohibit turns as necessary for traffic conditions. 4. Extend device taper (U3) across shoulder — recommended. 5. Closing lane in advance of flagging location when multiple lanes are on approach leg — recommended. 6. Maintain a minimum of one access point for each business within the Work Area limits 7. Flashing Warning Lights (Type A per MUTCD) should be used, as needed, to mark barricades at night. 8. Steady Burning Waming Lights (Type C per MUTCD) shall be used to mark channelizing devices at night. 9. For long term projects, conflicting pavement markings that are no longer applicable shall be removed or obliterated. Temporary markings shall be used as necessary. 10. For signs size refer to Manual on Uniform Traffic Control Devices (MUTCD) and WSDOT Sign Fabrication Manual M55-05. RECEIVED DEC 262012 %egra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 ENGIN INT S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE TRAFFIC CONTROL SHEET 18 OF 20 PUBLIC WORKS L3 G20 -2A -- L X W20 -7A W20-78 W20-4 W20-1 X X p WORK AREA O 0 0 W20-1 W20-4 W20-78 W20 -7A x LEGEND • ■ o 444 SIGN LOCATION CHANNELIZING DEVICES ARROW PANEL FLAGGING STATION 11 G20 -2A SIGN SPACING (1) = X RURAL HIGHWAYS RURAL ROADS RURAL ROADS dr URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL F. BUSINESS DISTRICTS URBAN STREETS 60 / 65 MPH 45 / 55 MPH 35 / 40 MPH 800' t 500' t 350' ± 25 / 30 MPH 200' t (2) 25 MPH OR LESS 100' t (2) ALL SIGNS ARE BLACK ON ORANGE UNLESS DESIGNATED OTHERWISE (1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS, AND DRIVEWAYS. (2) THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH = L (FEET) LANE WIDTH (FEET) 25 POSTED 30 35 SPEED 40 (MPH) 45 50 55 10 105 150 205 270 450 500 550 11 115 165 225 294 495 550 605 12 125 180 245 320 540 600 660 CHANNELIZATION DEVICE SPACING POSTED SPEED IN TAPER IN TANGENT (MPH) (FEET) (FEET) 50 / 70 40 80 35 / 45 30 60 25 / 30 20 40 NOTES 1. If the work space extends across a crosswalk, the crosswalk should be closed (see Standard Plan K-34.20). 2. Devices shall not encroach into adjacent lanes. 3. Use Traverse Devices in closed lane every 1000'+/ - recommended. 4, Flashing Waming Lights (Type A per MUTCD) should be used, as needed, to mark barricades at night. 5. Steady Burning Waming Lights (Type C per MUTCD) shall be used to mark channelizing devices at night. 6. Channelizing Device spacing for the downstream taper option shall be 20' O.C. 7. For signs size refer to Manual on Uniform Traffic Control Devices (MUTCD) and WSDOT Sign Fabrication Manual M55-05. RECEIVED t itG 281012 UKVVILA PUBLIC WORKS (g?tegra® TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS INC. ENGINEERING Communications A Q UANTA 10860 SW CLUTTER SHERWOOD, OREGON CONTACT: DAVID P: 360.772.2143 ASSOCIATES, Engineers SERVICES COMPANY ROAD 97140 BARNETTE p,S r fj,� ENGI ° :• r rp ,mak T A r ' T o 45735 'ONAL r� INTERN : I '� E & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE TRAFFIC CONTROL SHEET 19 OF 20 G13 -oo/ SIGN SPACING (1) = X RURAL HIGHWAYS RURAL ROADS RURAL ROADS do URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS 60 / 65 MPH 45 / 55 MPH 35 / 40 MPH 25 / 30 MPH 800' ± 500' ± 350' ± 200' ± (2) 25 MPH OR LESS 100' ± (2) ALL SIGNS ARE BLACK ON ORANGE UNLESS DESIGNATED OTHERWISE (1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS. AT -GRADE INTERSECTIONS, AND DRIVEWAYS. (2) THIS SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. G20 -2A 1.4 b W20-1 W20-4 W20— 7B LEGEND W20 -7A SIGN LOCATION CHANNELIZING DEVICES ARROW PANEL FLAGGING STATION 0 0 0 0 0 NOTES 1. If the work space extends across a crosswalk, the crosswalk should be closed (see Standard Plan K-34.20). 2. Devices shall not encroach into adjacent lanes. 3. Use Traverse Devices in dosed lane every 1000'+/ - recommended. 4. Flashing Waming Lights (Type A per MUTCD) should be used, as needed, to mark barricades at night. 5. Steady Burning Waming Lights (Type C per MUTCD) shall be used to mark channelizing devices at night. 6. Channelizing Device spacing for the downstream taper option shall be 20' O.C. 7. For signs size refer to Manual on Uniform Traffic Control Devices (MUTCD) and WSDOT Sign Fabrication Manual M55-05. x C 0 G20 -2A G20 -2A MINIMUM TAPER LENGTH = L (FEET) LANE WIDTH (FEET) 25 POSTED 30 35 SPEED 40 (MPH) 45 50 55 10 105 150 205 270 450 500 550 11 115 165 225 294 495 550 605 12 125 180 245 320 540 600 660 CHANNELIZATION DEVICE SPACING POSTED SPEED IN TAPER IN TANGENT (MPH) (FEET) (FEET) 50 / 70 40 80 35 / 45 30 60 25 / 30 20 40 W20 -7A W20 -7B W20-4 W20-1 W20 -7A W20 7B W20-4 W20-1 G20 -2A RECEIVED DEC 282012 FUKVV LA PUBLIC WORKS tQtegra° TELECOM 1201 NE LLOYD BOULEVARD SUITE 500 PORTLAND, OR 97232 CORP. 503.453.8000 FAX. 503.453.8221 THE INFORMATION CONTAINED HEREIN IS HIGHLY CONFIDENTIAL AND COMPETITIVELY SENSITIVE. DISCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF INTEGRA TELECOM WILL SUBJECT THE DISCLOSING PARTY TO LEGAL ACTION, INJUNCTIVE RELIEF AND PENALTIES TO THE FULLEST EXTENT OF THE LAW. CONSULTANTS ENGINEERING ASSOCIATES, INC. Communications Engineers A Q UANTA SERVICES COMPANY 10860 SW CLUTTER ROAD SHERWOOD, OREGON 97140 CONTACT: DAVID BARNETTE P: 360.772.2143 IN • '=• + & S 133RD ST TO S 120TH ST TUKWILA, WA MARK DATE DISCRIPTION ISSUE: PROJECT NO: DWG FILE: DRAWN BY: CHECKED BY: SHEET TITLE TRAFFIC CONTROL SHEET 20 OF 20 Ld3--00/