Loading...
HomeMy WebLinkAboutPermit D17-0029 - WESTFIELD SOUTHCENTER MALL - TRASH ENCLOSUREWESTFIELD SOUTHCENTER - TRASH ENCLOSURE 2800 SOUTHCENTER MALL L17-0029 Parcel No: Address: Project Name: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 2800 SOUTHCENTER MALL Permit Number: Issue Date: Permit Expires On: WESTFIELD SOUTHCENTER - TRASH ENCLOSURE 017-0029 3/29/2017 9/25/2017 Owner: Name: Address: Contact Person: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 BEN FERGUSON Address: 1918 JEFFERSON AVE , TACOMA, WA, 98402 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA, 98580 License No: JEMCOI*033DD Lender: Name: WESTFIELD SOUTHCENTER Address: 2800 WESTFIELD MALL, TUKWILA, WA, 98188 Phone: (253) 248-6060 Phone: (253) 843-2765 Expiration Date: 5/15/2017 DESCRIPTION OF WORK: BUIILD A NEW ENCLOSURE AROUND THE EXISTING TRASH COMPACTORS ON THE WEST SIDE OF THE PROPERTY Project Valuation: $30,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $1,178.28 Occupancy per IBC: U Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No 1:11- Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and .gree to the conditions attached to this permit. Signature: Print Name: '76)2-7 Date: Y Q9 02 d/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction, documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected' and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0201 FOOTING 0409 FRAMING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Project No. Date Application Accepted: Date Application Expires: CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 2800 Southcenter Mall Tenant Name: Westfield SouthCenter King Co Assessor's Tax No.:. 920247-0010 Suite Number: Floor: 1St PROPERTY OWNER Name: Ben Ferguson Name: Westfield Southcenter . City: Tacoma State: WA Zip: 98402 Address: 2800 Southcenter Mall Email: bferguson@fergusonarch.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Ben Ferguson Address: 1918 Jefferson Ave City: Tacoma State: WA Zip: 98402 Phone: (253) 248-6060 Fax: Email: bferguson@fergusonarch.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: Ferguson Architecture Company Name: TBD Architect Name: Ben Ferguson Address: Address: 1918 Jefferson Ave City: Tacoma State: WA City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications \Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes ®..No ARCHITECT OF RECORD Name: Westfield Southcenter Company Name: Ferguson Architecture Company Name: TBD Architect Name: Ben Ferguson Cit': Tukwila State: WA Address: 1918 Jefferson Ave City: Tacoma State: WA Zip: 98402 Phone: (253) 248-6060 Fax: Email: bferguson@fergusonarch.com State: ENGINEER OF RECORD Name: Westfield Southcenter Company Name: TBD Cit': Tukwila State: WA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) ; . Name: Westfield Southcenter Address: 2800 Westfield Mall Cit': Tukwila State: WA Zip: 98188 Page 1 of 4 BUILDING PERMIT INFORMAT-- 206-431-3670 Valuation of Project (contractor's bid price): $38,000 Describe the scope of work (please provide detailed information): Build a new enclosure around the existing trash compacors on the west side of the property. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes . No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing - Structure New Type of Construction per IBC Type of Occupancy per IBC P' Floor 710 - 11N M 2"d Floor - -- 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT IN NATION:-.206-433_-OI79'7�= Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 O ...Water Availability Provided Sewer District 0 ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ ...Valley View 0 .. Renton ❑ ...Sewer Availability Provided 0 .. Renton 12.. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities O ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention cubic yards cubic yards Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ .':.Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 0 ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 O ...Water Main Extension Public 0 WO # WO # WO # Private 0 Private 0 ❑ .. Grease Interceptor 0 .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: . Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\201 1 Applications \Permit Application Revised - 8.9-11.docx .Reviscd: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE OR AUT - GENT: Signature: Print Name: Ben Fer Mailing Address: 1918 Jefferson Ave I-:\Applications\Forms-Applications On Line \201 Applications\Fermit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: 02/10/2017 Day Telephone: (253) 248-6060 Tacoma WA 98402 • City State Zip Page 4 of 4 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $729.48 D17-0029 Address: 2800 SOUTHCENTER MALL Apn: 9202470010 $729.48 DEVELOPMENT $694.96 PERMIT FEE R000.322.100.00.00 0.00 $690.46 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $34.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11164 R000.322.900.04.00 0.00 $34.52 $729.48 Date Paid: Wednesday, March 29, 2017 Paid By: J E M CONSTRUCTION INC Pay Method: CHECK 15048 Printed: Wednesday, March 29, 2017 8:58 AM 1 of 1 CSYSTEMS Cash Register .Receipt. City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $448.80 D17-0029 Address: 2800 SOUTHCENTER MALL Apn: 9202470010 $448.80 DEVELOPMENT $448.80 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R10847 R000.345.830.00.00 0.00 $448.80 $448.80 Date Paid: Friday, February 17, 2017 Paid By: FERGUSON ARCHITECTURE Pay Method: CHECK 5019 Printed: Friday, February 17, 2017 10:51 AM 1 of 1 CSYSTEMS w A INSPECTION RECORD Retain a copywith ermit �a7 _ 062q INS "moi► NO. p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Wal—c/ 6 l Tyftje of Inspection: '3u'izziA/ ri✓i41_ Address: Zeo 17•1e&,' r illAa- Date Called: Special Instructions: ' .. 5/'1 L,ra oSVie .- Date Wanted: 4 / f /7 a.m p.m. Requester; At O13 Phone No: 2 -S -I 6o SW2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: if REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Pf II DJ I I INSPECTION RECORD Retain a copy y withpermit INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 1)l-? oOZt3 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: lasnfiet. garn4e6Pree Type nspection: wl/r- Address: at) ril [.L_ Date Called: Special Instructions: 7-79A94Nc'C.f5veliee Date Wanted l% >l l `l a".rr� p. Requeste . Phone No: rd Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: A ) Pflivi Date: /17 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 b17- 2.c? Project: IJ.S5 PiE D Gufl/CEJCTrj Type of Inspection: r71t — Address: 2e0e -530Th CiNT7R AMA Date Called: Special Instructions: Date Wanted: 3-30—i 7 a.m I t - INCLU)R/2 .m. Requester: Phone No: k Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0029 DATE: 02/22/17 PROJECT NAME: WESTFIELD SOUTHCENTER - TRASH ENCL SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Pry MO 71r Building Divisio .1%14 Ner 1171 Public Works �(1 .0//1---0-- Fire Prevention Structural APg. 01T Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 02/22/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) 03/23/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 J E M CONSTRUCTION INC Home. Espanol Contact Safety & Health Claims & Insurance 02) Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My UT Workplace Rights Trades & Licensing J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA 98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JEMCOI*033DD Effective — expiration 03/04/1997— 05/15/2017 Bond ........_....._ CBIC Bond account no. SA7695 $12,000.00 S Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled Insurance .......................... American States Insurance Co $1,000,000.00 Policy no. 01C12205496 Received by. L&I . Effective date 03/23/2017 . 04/16/2015 Expiration date 04/16/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 3/29/2017 J E M CONSTRUCTION INC L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some ices may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 968,907-00 Doing business as J E M CONSTRUCTION INC Estimated workers reported Quarter 4 of Year 2016 "4 to 6 Workers" L&I account representative T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 3/29/2017 ABBREVIATIONS ADJ ALT AFF ALUM ANG ANOD AC BLDG BLK'G BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FACTORY FINISH OR FINISH FLOOR FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR GRAPHIC LEGEND II III—III- 0 0 11•1111I (ttt 1111 !III 11 • • I/////�1 EARTH GRAVEL/ROCK CONCRETE ASPHALT PAVING WOOD FRAMING BLOCKING OR SHIM FINISH WOOD GLASS(ELEVATION) GLASS(SECTION) GYPSUM WALL BOARD CAULKING/SEALANT PLYWOOD BRICK ACOUSTIC TILE RIGID INSULATION BATT INSULATION METAL SYMBOLS LEGEND OFC (1024) GW -® GRID LINES ROOM NAME ROOM NUMBER DOOR NUMBER CEILING HEIGHT CEILING TYPE GW = GYPSUM WALLBOARD AC = ACOUSTICAL CEILING DATUM OR PROPERTY CORNER KEYNOTE FTIC FT FURN GA GALV GL GW OR GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FURNISHED BY TENANT INSTALLED BY CONTRACTOR FOOT/FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE SYMBOLS LEGEND CONT. VCT CPT SV WM VINYL COMPOSITION TILE CARPET SHEET VINYL WALK -OFF MATT INTERIOR ELEVATION REFERENCE ELEVATION / SECTION REFERENCE T EGRESS DIRECTION i EGRESS PATH EGRESS START POINT NORTH ARROW DETAIL REFERENCE DETAIL SECTION / PLAN CUT ENLARGED PLAN REFERENCE 2 OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERST TYP UNO VAR VCT VERT VWC W/ W/0 WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM. ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL UNLESS NOTED OTHERWISE VARIES VINYL COMPOSITION TILE VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD ELECTRICAL SYMBOLS DUPLEX OUTLET C DEDICATED DUPLEX OUTLET FOURPLEX OUTLET DEDICATED FOURPLEX OUTLET VOICE / DATA OUTLET RECESSED FLOOR VOICE / DATA OUTLET 208V OUTLET 220V OUTLET OVERHEAD FEED FURNITURE POWER / DATA POLE OVERHEAD ELECTRICAL DROP CORD SPECIAL OUTLET (SEE KEYNOTES) CARD READER OUTLET ELECTRICAL JUNCTION BOX SECURITY SYSTEM ACCESS PANEL LIGHTING SWITCH THREE-WAY LIGHT SWITCH LIGHTING OCCUPANCY SENSOR HVAC THERMOSTAT 3 GENERAL NOTES 1. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS INCLUDING LOCAL JURISDICTIONAL AND OWNER REQUIREMENTS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK THAT COULD BE EFFECTED BY THE DISCREPANCY SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 4. SEPARATE PERMITS, WHEN REQUIRED AND/OR ARE DESIGN/BUILD , SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND SUPPLEMENTAL DOCUMENTS SHALL BE PROVIDED FOR REVIEW BY THE AUTHORITY HAVING JURISDICTION AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. 5. THE INSTALLATION OF AUTOMATIC FIRE SPRINKLER AND ALARM SYSTEMS SYSTEMS SHALL COMPLY WITH THE INTERNATIONAL BUILDING AND FIRE CODES. 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE SCOPE OF WORK SHALL BE PERFORMED BY A APPROVED INSPECTION SERVICE APPROVED BY THE AUTHORITY HAVING JURISDICTION OR BUILDING OFFICIAL. 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. 8. DIMENSIONS ARE TO LEASE LINE UNLESS NOTED OTHERWISE. 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER. 12. ALL WORK AND MATERIALS SHALL BE PLACED / INSTALLED IN FULL ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE IN AFFECT WITHIN THE JURISDICTION WORK IN PERFORMED AND ALL OTHER APPLICABLE STATE OR LOCAL LAWS AND REGULATIONS AS ARE APPLICABLE. NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO PERMIT WORK WHICH IS NOT IN CONFORMANCE WITH ANY CODE OR REGULATION IN AFFECT. 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICES. 15. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED AT LOCATION PER IBC SEC. 718 . 16. WHEN CHANGES TO THE MECHANICAL SYSTEM REQUIRE A MECHANICAL PERMIT THEY SHALL COMPLY WITH THE CURRENT MECHANICAL CODE, WASHINGTON STATE ENERGY CODE AND ANY LOCAL JURISDICTION REQUIREMENTS. 17. PROVIDE ILLUMINATED EXIT SIGNAGE WITH MIN. 45 MINUTES BACKUP POWER AT ALL REQUIRED EXITS. 18. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND ALTERED BY NEW CONSTRUCTION. 19. CONTRACTOR IS TO COMPLY WITH CHAPTER 33 OF THE INTERNATIONAL BUILDING CODE CONCERNING PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. 20. ASBESTOS AND HAZARDOUS WASTE : THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. 21. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL MIN, OF 3 FIRE EXTINGUISHERS OR AS OTHERWISE REQUIRED BY LOCAL JURISDICTION. VERIFY LOCATIONS WITH WESTFIELD FACILITY MANAGER. 3 AREA OF WORK CODE INFORMATION 2015 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS ICC/ANSI A117.1-09, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 2015 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLER SYSTEM: FIRE SEPARATION REQUIREMENTS: M (MERCANTILE - COVERED MALL) II -N FULLY SPRINKLERED IBC SECTION 1024.5 OPENINGS - DOORS TO EXIT PASSAGEWAYS SHALL BE PROTECTED BE 60 MINUTE RATED DOOR AND FRAME ASSEMBLY THAT IS SELF CLOSING. EACH TENANT SPACE SHALL BE SEPARATED BY A FIRE PARTITION (60 MINUTES RATED) IN ACCORDANCE TO IBC SECTION 708. FLOOR AREAS: AREA OF WORK: EXISTING TRASH COMPACTORS 710 SQ. FT. LIGHTING REQUIREMENTS NO LIGHTING CHANGES PROPOSED IN SCOPE OF WORK. ENERGY REQUIREMENTS NO BUILDING ENVELOPE MODIFICATIONS PROPOSED IN SCOPE OF WORK. PLUMBING FIXTURE REQUIREMENTS NO PLUMBING WORK PROPOSED IN SCOPE OF WORK. WESTFIELD SOUTHCENTER MALL PROJECT DIRECTORY ARCHITECT / CONTACT: OWNER: GENERAL CONTRACTOR: TAX PARCEL # 920247-0010 FERGUSON ARCHITECTURE 1916 JEFFERSON AVENUE TACOMA, WASHINGTON 98402 CONTACT: BEN FERGUSON PHONE: (253) 248-6060 EMAIL: bferguson@fergusonarch.com WESTFIELD SOUTHCENTER 2800 WESTFIELD MALL TUKWILA, WASHINGTON 98188 CONTACT: PHONE: EMAIL: TBD LEGAL DESCRIPTION DUSTIN JACKSON 206 246-0423 dujackson@westfield.com 101 3 WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) ADDRESS 2800 SOUTHCENTER TUKWILA, WA 98188 No changes sh l► i,— r- gra to the scope of work withou;: , e pprovai of Tukwila Building Division. NOTE: Revisions will require a new plan submittat and may include additional plan review fees. PROJECT DESCRIPTION BUILD A NEW (2) SIDED 8'-0" HIGH SIGHT OBSCURING ENCLOSURE AROUND EXISTING TRASH COMPACTOR THAT SERVES SEARS. INDEX OF DRAWINGS A1.0 PROJECT REAM, INDEX & CODE INFORMATION A2.1 TRASH ENCLOSURE DEMO PLAN, FLOOR PLAN & DETAILS LB CCF Y No, DO' o Ian rJiLy4^� . . c slczv1to Ls J .�.—.� L:i ....v '''iri t 1• Approval pit" COni4,s _.1iL , LFI'; ai- C;OC the violation of any adopted code or crdinanco. ► zr:: t of approved Field Copy and conditions is acknowledocd: By: Date: City of Tukwila BUILDING DIVISION /14147 ()NORDSTROM macys 3 LEVELS 4 LEVELS /53,0010 o ❑ �oo 0 JCPenney 3 LEVELS .271.%7e/ REVIEWED FOR 'CODE COMPLIANCE APPROVED KR022011 SSS 3 LEVELS 1" . City of Tukwila UILDING DIVISION Zit 31 33 4 OVERALL MALL PLAN ECEIVED OF TUKWILA EB 17 2017 MIT CENTER B EN STA REGISTERED AR HITECT D; r►T E , USON OF HINGTON LIJ O�z ow 901 J=O Qco �� J I— W H CnW 2800 SO UTH C E NTE R TU KW I LA, WA 98188 SEPARrITE_a it.i;IT c Q'j7.7- FOR: 'rVioc anicat (g'E!ectncat (i�'Pi;:mbing LT -'as Piping C:;1 j oa Tukwila fel `' r -.,_•_r f"' �lI ION REVISIONS: DATE: PROJECT NO: PRINCIPAL -IN -CHARGE: PROJECT MANAGER: DRAWN BY: 02/10/2017 009-06-16 BEN BEN RORY PHASE / DELIVERABLE: D PERMIT SET SHEET TITLE: PROJECT TEAM INDEX CODE INFORMATION SHEET NO. A1.0 1 GATE PLAN 8'-O" L J \ / 1 / 1 I 1 I II II 11'-9"+ 7 1/4" GUSSET PLATE TYPICAL ALL CORNERS J Do - %" STEEL ROD KEEPER IN SLEEVE WELDED TO GATE FRAME - BLACK POWDER COAT FINISH. A- INSIDE ELEVATION GATE ELEVATION 1/2" =1'-0" 6-11" 2 1" X 5X" SQUARE EDGE TREK BOARDS SCREWED TO GATE FRAME AND (3) EQUALLY SPACED 18 GA GALV. HAT CHANNELS. TREK COLOR: GRAVEL PATH 4" X 4" Xy" TUBE STEEL GATE POST FINISHED WITH BLACK POWER COATED FINISH 1 Y" SQ. XX" STEEL TUBING GATE FRAME WITH BLACK POWER COATED FINISH 3" X 12" Xy" PLATE WELED TO HINGE AND BOLTED TO GATE FRAME WITH (2) %" DIA. X 2X" BOLT W/ NUT AND LOCK WASHERS %" DIA STEEL ROD WITH TURNBUCKLE WELDED TO X" GUSSET PLATES 4" X 4" Xy" TUBE STEEL GATE POST FINISHED WITH BLACK POWER COATED FINISH 1" DIA. H.D. BALL BEARING HINGE WELED TO 4" X 4" POST (MATCH HINGES AT EXISTING TRASH ENCLOSURE ON SITE) 12" DIA. X 48" CONC. FOOTING GATE POST FOOTING 6'-11" 8'-O" B2 -I 1 L J L - - _ J GATE SECTION 1/2" =1'-0" - EXPANSION JOINT - TO ALIGN WITH ADJACENT MALL WALL Al PLASTER WALL - ELEVATION 1/2" =1'-0" 1 2 4'-0" 3'-0" 3 1 X" SQ. Xy" STEEL TUBING GATE FRAME WITH BLACK POWER COATED FINISH 1" X 5y" SQUARE EDGE TREK BOARDS SCREWED TO GATE FRAME AND (4) EQUALLY SPACED 18 GA GALV. HAT CHANNELS. TREK COLOR: GRAVEL PATH INSIDE ENCLOSURE FINISH GRADE) 12" DIA. X 48" CONC. FOOTING GATE POST FOOTING 8'-O" A3 1 FLASHING CAP - COLOR -SANDSTONE EXISTING BRICK WALL PAPER -BACKED METAL LATH 8'-O" 1 B3 "DRYVIT" STUCCO FINISH THIN "COLOR" COAT - #10 G PEARL ASH - OVER 3/8" BROWN COAT OVER 3/8" SCRATCH COAT *SOUTH & WEST SIDE ONLY* WEEP SCREED 0'-2" MIN. BRICK WALL SECTION 1/2" =1'-0" 3 1- L J 4 1" X 5Y" SQUARE EDGE TREK BOARDS SCREWED TO (5) EQUALLY SPACED 14 GA GALV. HAT CHANNELS. TREK COLOR: GRAVEL PATH 4" X 4" Xy" TUBE STEEL ENCLOSURE POST FINISHED WITH BLACK POWER COATED FINISH INSIDE ENCLOSURE 12" DIA. X 48" CONC. FOOTING ENCLOSURE POST FOOTING SCREEN SECTION 1/2" =1'-0" 2 Y2" MIN. LAP FORMED METAL COPING - COLOR SANDSTONE SOLID BLOCKING CONTINUOUS CLEAT ATTACH TO BLOCKING EXISTING BRICK WALL PAPER -BACKED METAL LATH - "DRYVIT" STUCCO FINISH THIN "COLOR" COAT - #10 G PEARL ASH - OVER 3/8" BROWN COAT OVER 3/8" SCRATCH COAT *SOUTH & WEST SIDE ONLY* EXISTING BRICK WALL PAPER -BACKED METAL LATH "DRYVIT" STUCCO FINISH THIN "COLOR" COAT - #10 G PEARI ASH - OVER 3/8" BROWN COAT OVER 3/8" SCRATCH COAT *SOUTH & WEST SIDE ONLY* WEEP SCREED STUCCO BASE & COPING DETAILS 1-1/2"" =1'-0" 4 B5 5 ADA RAMP TO REMAIN DEMOLISH BOLLARD TRASH ENCLOSURE DEMO PLAN 1/8" =1'-0" 7'-5" 7'-5" TRASH 1 COMPACTOR RECEIVED ITY OF TUKWILA FEB 17 2017 ERM REVISIONS: DATE: PROJECT NO: PRINCIPAL -IN -CHARGE: PROJECT MANAGER: DRAWN BY: 2800 SOUTHCENTER TUKWILA, WA 98188 02110/2017 009-06-16 BEN BEN RORY PHASE / DELIVERABLE: D PERMIT SET TRASH ENCLOSURE PLAN 1/8" =1'-0" SHEET TITLE: GBAGE ENCLOSURE 0 PLAN, FLOOR N & DETAILS T QMEWED FO CODE COMPLIAN APPROVED PL MAR 0 212011 SHE T NO. A2.1