Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0037 - LIONESSE - TENANT IMPROVEMENT
LIONESSE 690 SOUTHCENTER MALL EXPIRED 03/12/18 D17-0037 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 690 SOUTHCENTER MALL Project Name: LIONESSE Permit Number: D17-0037 Issue Date: 3/16/2017 Permit Expires On: 9/12/2017 Owner: Name: Address: Contact Person: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 GIL YARIMI Address: 215 NW 2ND PL, RENTON, WA, 98057 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA, 98580 License No: JEMCOI*033DD Lender: • Name: ANYG MARKETING INC Address: 215 NW 2ND PL, RENTON, WA, 98057 Phone: (856) 899-4484 Phone: (253) 843-2765 Expiration Date: 5/15/2017 DESCRIPTION OF WORK: Lionesse TI 18 feet of new walls, new door, millwork, cosmetic interior finishes, no HVAC or plumbing on this project Project Valuation: $10,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $515.94 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: (.0 Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No% � Permit Center Authorized Signature: it,gp44 Date: / ' 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: G '10`z_ 1V it Print Name: ~ j r 1 I Gtr rl i Date: iiG//i This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval) is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. o a 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 16: Maintain fire extinguisher coverage throughout. 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 21: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 25: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). D C� 26: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 28: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 31: Post address on storefront per approved Westfield standards. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 33: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** ITE LE?CATII Site Address: 690 Soutchenter Mall Tenant Name: Lionesse King Co Assessor's Tax No.: Suite Number: Floor: 1 New Tenant: 0 Yes 0 ..No PROPERTY OWNER Name: Westfield Southcenter Mall Address: 2800 Southcenter Mall City: Seattle State: Wa Zip: 98188 ................................................ ......................................................... .......................................................... CONTACTP!E communication Name: Gil Yarimi Address: 215 NW second Place City: Renton State: Wa Zip: 98057 Phone: (856) 899-4484 Fax: Email: gilyarimi@icloud.com GENERAL ;CONTRACTOR INFORMATION' Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applicationa\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITE{ Company Name: COQ• Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGl IF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: ENDER/BOND ISSUED {required forprojects rperRCW X9,7095)' Name: A. 6 /"l Gxrit 42C Address: 2-15 AJ / 2/l P L City: pe 04_0 t\ State: ( v4 Zip:q80 5-7 Page 1 of 4 BUILDINGPERMIT INFOR11 TIO i Valuation of Project (contractor's bid price): $ 10,000 Describe the scope of work (please provide detailed information): Cosmetic interior finishes to include new wallpaper installation and new paint of millwork. Approximately 18 linear feet of new partial height wall at 7-6" high. Installation of shelving on existing millwork. One new interior door to be installed. No HVAC or Plumbing work to be done on this project. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All B,�►g Areas SgtottiFooiagt. cI oor 1,524 769 0 0 IIB Mercantile ................................ Basement Accessory Structur Ati ;Attach Covered ] Utieov PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 2 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\For ms -Applications On Line\201 I ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 136 Page 2 of 4 PUBLIC WORIKS ?EMIT INFORMATION 200,:4p-0179. Scope of Work (please provide detailed information): None Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District 0 ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Stone Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance 0 .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor 0 ...Cap or Remove Utilities ❑ .. Curb Cut 0 .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line 0 .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water 22 0 ...Permanent Water Meter Size... 22 WO # ❑ ...Temporary Water Meter Size .. 5 2 WO # ❑ ...Water Only Meter Size 22 WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter RefundBilling: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 ApplicatiooatPermit Application Revised - 8-9-11.docz Revised: August 2011 bh Page 3 of 4 Fl LIGITION',NOTE5i4.; Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: `� �. - Date: 02/28/2017 Print Name: Collins Esguerra Day Telephone: Mailing Address: 20255 Corisco st Chatsworth City H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docz Revised: August 2011 bh (661) 964-7998 Ca state 91311 zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $451.27 D17-0037 Address: 690 SOUTHCENTER MALL Apn: 9202470010 $320.44 Credit Card Fee $9.33 Credit Card Fee R000.369.908.00.00 0.00 $9.33 DEVELOPMENT $296.51 PERMIT FEE R000.322.100.00.00 0.00 $292.01 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $14.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.60 EL17-0157 Address: 690 SOUTHCENTER MALL Apn: 9202470010 $130.83 Credit Card Fee $3.81 Credit Card Fee R000.369.908.00.00 0.00 I $3.81 ELECTRICAL $120.97 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 0.00 I $120.97 TECHNOLOGY FEE $6.05 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11099 R000.322.900.04.00 0.00 $6.05 $451.27 Date Paid: Friday, March 17, 2017 Paid By: GIL YARIMI Pay Method: CREDIT CARD 118841 Printed: Thursday, March 16, 2017 4:39 PM 1 of 1 CRP/SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $195.50 D17-0037 Address: 690 SOUTHCENTER MALL Apn: 9202470010 $195.50 Credit Card Fee $5.69 Credit Card Fee R000.369.908.00.00 0.00 $5.69 DEVELOPMENT $189.81 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R10944 R000.345.830.00.00 0.00 $189.81 $195.50 Date Paid: Tuesday, February 28, 2017 Paid By: GIL YARINI Pay Method: CREDIT CARD 028498 Printed: Tuesday, February 28, 2017 2:30 PM 1 of 1 CRSYSTEMS 2/1/2018 City of Tukwila Department of Community Development GIL YARIMI 215 NW 2ND PL RENTON, WA 98057 RE: Permit No. D17-0037 LIONESSE 690 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/12/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/12/2018, your. permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle Ripley Permit Technician File No: DI7-0037 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 J City of Tukwila 0 Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 23, 2017 Gil Yarimi 215 NW 2nd P1 Renton, WA 98057 RE: Request for Extension #1 Permit Number D17-0037 Dear Mr. Yarimi, This letter is in response to your written request for an extension to Permit D17-0037. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through March 12, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rachel e Riplby Permit Technician File: Permit No. D17-0037 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Rachelle Ripley From: anyg marketing <anygmarketinginc@gmail.com> Sent: Thursday, August 17, 2017 4:04 PM To: Rachelle Ripley Good afternoon We would like to extend our permit for lionesse ( southcenter) to April 2018. Lionesse 690 southcenter mall Permit No. D17-0037 Gil- 8568994484 Gil yarimi 215 nw 2nd pl Renton wa 98057 Thanks : ) Request for Extension # q Current Expiration Date: 6111' M Extension Request: 1 f Approved for /rd Denied (provide explanation) days Signature/Initials _1Y 1 1 J 8/1/2017 Q City of Tukwila Department of Community Development GIL YARIMI 215 NW 2ND PL RENTON, WA 98057 RE: Permit No. D17-0037 LIONESSE 690 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/12/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180. days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/12/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle ' ipley Permit Technician File No: D17-0037 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 tOPEAMIT COORD COPY" PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0037 DATE: 03/01/17 PROJECT NAME: LIONESSE SITE ADDRESS: 690 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ft3T Auk,3 �7 Building Division D1i VA gA. t Public Works KM 1%0 \\11•\1/1 Fire Prevention Structural Kolit Or 11 Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 03/02/17 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 03/30/17 Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initial's: 12/18/2013 J E M CONSTRUCTION INC Horne Fspanol Contact Safety & Health Claims & Insurance Washington State Department of 40 Labor & Industries Search L&I Page 1 of 2 A -Z Index help My L&1 Workplace Rights Trades & Licensing J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA 98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JEMCOI*033DD Effective — expiration 03/04/1997— 05/15/2017 Bond CBIC Bond account no. SA7695 $12,000.00 Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled Insurance .............. ............ American States Insurance Co $1,000,000.00 Policy no. 01012205496 Received by L&I Effective date 03/29/2016 04/16/2015 Expiration date 04/16/2017 Insurance history Savings ............ No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 03/16/2017 J E M CONSTRUCTION INC LSI Tax debts No LSI tax debts are recorded for this contra .. license during the previous 6 year period, but some da xa may be recorded by other agencies. License Violations ....................................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 968,907-00 Doing business as J E M CONSTRUCTION INC Estimated workers reported Quarter 4 of Year 2016 "4 to 6 Workers" L&I account representative T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 03/16/2017 DRAWING INDEX ARCHITECTURAL A00.00 COVER SHEET A00.01 GENERAL NOTES A00.02 GENERAL NOTES A00.03 GENERAL NOTES A01.01 DEMOLITION PLAN & EXISTING CEILING PLAN. A02.01 PROPOSED PLAN A04.01 REFLECTED CEILING PLAN A05.01 FINISH PLAN A06.01 FURNITURE AND POWER PLAN A11.01 STOREFRONT ELEVATION A11.02 INTERIOR ELEVATIONS A11.03 INTERIOR ELEVATIONS A13.01 3D RENDERINGS SOUTHCENTER MALL 44, Axa SCOPE OF WORK • COSMETIC INTERIOR RENOVATION • NEW PARTIAL HEIGHT WALL. (7'-6" HEIGHT) • NO STRUCTURAL WORK TO BE DONE IN THIS PERMIT. PROJECT TEAM OWNER: DESIGNER: LIONESSE 20255 Corisco St. Chatsworth, CA 91311 Voice: 818.886.3200 E-mail: Contact: LIONESSE 20255 Corisco St. Chatsworth, CA 91311 Voice: 818.886.3200 ext 301 E-mail: ana@mazalent.com Contact: Ana Garcia PROJECT INFORMATION ADDRESS CONSTRUCTION TYPE USER GROUP SQUARE FOOTAGE CODE CLASSIFICATION SOUTHCENTER MALL TYPE II -B M -MERCANTILE 1524 SFT IBC 2015 WASHINGTON STATES ENERGY CODE 2015 ED. INTERNATIONAL MECHANICAL CODE 2015. OCCUPANCY LOAD: TOTAL GROSS SQ FT : ± 1524 SQ FT MERCANTILE: 769/30 = 26 STORAGE (M): 755/300 = 3 TOTAL OCC. LOAD = 29 ALL LOAD CALCULATION BASED ON 2015 IBC. CODE TABLE 1004.1.2 Working Drawing Review ■ Approved Approved as Noted Resubn it These drawirge have been reviewed fcr general design Intent only, All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Terant is responsible for complying with all government regulafrons. One (1) copy of this landlord stamped sat of drawings is requi red to be =-,•t on o = job site t all times. Si nets X2/27/2017 11:49:57 AM S`I" VV ,-3 �•_ _ I FOR: lemoci i,:anical 'Electrical lirPIumbing 'Gas Pip ng City of TEA/dila BUILDING DIVISION FILE COPY Permit No. t4i O0'1 Plan review cpprod is subject to errors and omissions. Approval of cons ri: iion documents ;uments does not authorize the violation of any adopted code or ordinance. Rccoipt of approved Field Copy and conditions is acknowledged: By: G.0.crti.., Date:, 3/i(01/ City of Tukwila BUILDING DIVISION SITE MAP sp 15Uth SI } 152n ti S uthcen�`��tfd S math St S 12 th Fd S 160th St ' Ril SW: rn Tukwila /•c tn Starflre Sports° Stack River Riparian Forest and Wetland ".'n NJ t Sb'! sung•+1U4d ett%st, sr v Walmart.Supercenter a Q King County South Treatment Plant sw COM ‘tri Q Ott Giad`,'NM 5`r tyt ' -01-tuf . f $W 76thSt y — Macy's Long-standing ;depart - tore Westfield Southeenter Si•levet shopping mall with movies iUW_IttU, S: a Stet":h St as. Courtyard by Marriott Seattle Southcenter SOUTHCENTER',, °Nordstrom Rack REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: f'^ttisi will r quire a new plan submittal i:.r,. :Ronal plan rev!sl'r f.-.. SW3:I1,(13 St RENTON LIONESSE MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 w cn w z 0 SUE ISSUE DESCRIPTION DATE CONSTRUCTION DRAWING 02.22.2017 SWQistrit IKEA Seattle Home Furnishings ° REVIEWED FOR CODE COMPLIANCE APPROVED 11 ,11 2017 Citjfid`f Tukwila ,BUILDING DIVISION *Carr R'= DRAWN BY: RECEIVE CITY OF TUK FEB 2 8 201 PERMIT CE TER SHEET LA SCALE COVER SHEET A 0 GENERAL NOTES 1. COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK. 2. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 3. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE DESIGNER FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION. 4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. 5. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION 7. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 8. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES, 9. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 10, MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION, COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY. 11. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF FINISHES. 13. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. FIRE DEPARTMENT NOTES 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. 2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 3. PROVIDE EMERGENCY LIGHTING OF ONE FOOT-CANDLE AT FLOOR LEVEL. COMPLY WITHBUILDING CODES. 4. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. 5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 6. DOORS OPENING INTO REQUIRED 1 -HOUR, FIRE -RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20 -MINUTE RATING AND SHALL BE SELF-CLOSING. 7. 20 -MINUTE DOOR JAMBS TO BE TIGHT -FITTING, SMOKE AND DRAFT CONTROLLED. 8. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. 9. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION. 10. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NON-COMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER. 11, PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. 12, STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. 13. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 14. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 15. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 16. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. FIRE DEPARTMENT NOTES CONT'D. 17. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 18. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. 20. THE INSPECTOR MAY REQUIRE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS AT THE TIME OF FINAL INSPECTION. 21. FIRE ACCESS ROAD AND WATER SUPPLY MUST BE INSPECTED AND APPROVED BY THE LOS ANGELES FIRE DEPARTMENT PRIOR TO LUMBER BEING DROPPED AT THE PROJECT SITE. A 2" THICK, 20' MIN. WIDE PAVED ASPHALT ROD SURROUNDING THE STRUCTURE MUST BE PROVIDED. CONTACT THE LOS ANGELES FIRE DEPARTMENT TO REQUEST AN INSPECTION WHEN THE PROJECT IS READY FOR INSPECTION. 22. SMOKE DETECTORS IN HVAC UNITS AND DAMPERS MUST BE MONITORED BY THE ALARM MONITORING THE FIRE SPRINKLERS AND SEPARATE PERMIT IS REQUIRED FOR THE ALARM CONNECTION, 23. FIRE PREVENTION BUREAU MUST INSPECT THE BUILDING FOR FINAL GRANT ACCEPTANCE BEFORE THE BUILDING DEPARTMENT IS SUMMONED FOR THEIR FINAL INSPECTION. CALL FIRE PREVENTION BUREAU FOR INSPECTION. 24. NOTE THAT THE PERSON REQUESTING FOR AN INSPECTION IS RESPONSIBLE FOR MEETING THE INSPECTOR ON TIME, PROVIDING ACCESS TO THE AREA REQUIRING INSPECTION AND PROVIDING AN APPROVED SET OF PLANS AND SUPPORTING DOCUMENTS 25. ANY ALTERATION TO THE EXISTING FIRE ALARM SYSTEM SHALL BE INSTALLED IN THIS BUILDING IN ACCORDANCE WITH 2011 PRBC. DETAILED PLANS AND SPECIFICATIONS SHALL BE SUBMITTED TO THE CITY FIRE PROTECTION ENGINEER FOR REVIEW AND A PERMIT SECURED PRIOR TO INSTALLATION. STRUCTURAL NOTES 1. ALL REQUIRED APPROVALS MUST BE OBTAINED FROM THE FIRE AND HAZARD PREVENTION SERVICES BEFORE THE BUILDING IS OCCUPIED. 2. EXIT DOORS TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3, FIRE AND/OR SMOKE DAMPER ASSEMBLIES, INCLUDING SLEEVES, AND INSTALLATION PROCEDURES SHALL BE APPROVED BY THE INSPECTION SERVICES DIVISION PRIOR TO INSTALLATION. 4. ELEVATOR LOBBIES SHALL HAVE ACCESS TO NOT LESS THAN ONE EXIT/EXIT ACCESS DOOR. SUCH DOOR(S) IN THE EXIT PATH FROM THE ELEVATOR LOBBY SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 5. PROVIDE AND MAINTAIN AN UNOBSTRUCTED MINIMUM HEADROOM CLEARANCE OF 7 FEET ALONG THE MEANS OF EGRESS SYSTEM. 6. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SUCH AS STANDPIPES, SPRINKLER SYSTEMS AND FIRE ALARM SYSTEMS, MUST BE SUBMITTED TO, AND APPROVED BY THE FIRE PREVENTION BUREAU BEFORE THIS EQUIPMENT IS INSTALLED. NOTE: NO STRUCTURAL WORK TO BE PERFORMED UNDER THIS PERMIT. DISABLED ACCESS NOTES 1. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. 2. FLOOR SURFACES SHALL BE SUP RESISTANT. 3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE NOT LESS THAN 44" IN WIDTH. 4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2. 5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 34" AND 44" ABOVE FLOOR FINISH. 6. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 34" AND 44" ABOVE THE FLOOR. 7. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRED DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. 8. THE BOTTOM OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. 9. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32". DISABLED ACCESS NOTES 10. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 11. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 12. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR, THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 13. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATED THAN 1:2. 14. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR WITHA STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. 15. CENTER ELECTRICAL RECEPTACLE NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORM. 16. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A BUILDING SHALL BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. 17. ENTRY TO THE SANITARY FACILITIES: A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE. B. WATER CLOSET DOORS SHALL BE EQUIPPED WITHA SELF-CLOSING DEVICE AND HAVE A MINIMUM 32" CLEARANCE WHEN LOCATED AT THE END (34" WHEN LOCATED AT THE SIDE). C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH. 18. TOILET ROOM ACCESSORIES: A. MOUNT BOTTOM EDGE OF MIRRORS NO HIGHER THAN 40" FROM THE FLOOR. B. MOUNT TOILET TISSUE DISPENSERS WITHIN 7"-9" FROM THE FRONT EDGE OF THE TOILET SEAT. C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR. 19. SINGLE ACCOMMODATION TOILET FACILITY: A. WATER CLOSET TO HAVE A 28" CLEARANCE FROM A FIXTURE AND 32" FROM A WALL. B. MINIMUM CLEAR SPACE IN FRONT OF WATER CLOSET TO BE 48". C. A SPACE 36"X48" IS PERMITTED IN FRONT OF EXISTING WATER CLOSET ACCESSIBLE TO THE HANDICAPPED. 20. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17" AND 19" 21. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF THE TOILET WITH THE GREATEST SEPARATION FROM ADJACENT WALL OR OTHER SURFACES. 22. PROVIDE GRAB BARS ON EACH SIDE, OR ONE SIDE AND BACK OF WATER CLOSET. A. GRAB BARS TO BE 36" ABOVE AND PARALLEL TO THE FLOOR. B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BARS AT BACK TO BE 36" LONG. C. DIAMETER OF GRAB BARS TO BE 1-1/4" TO 1-1/2". D. PROVIDE 1-1/ 2" CLEARANCE BETWEEN GRAB BARS AND WALL. E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL SUPPORT A 250 POUND LOAD. F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. G. GRAB BARS AND ANY ADJACENT SURFACES SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". 23. PROVIDE A CLEAR FLOOR SPACE 30"X48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH. 24. MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH, AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY. 25. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF CLOSING ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 26. INSULATE OR OTHERWISE COVER HOT WATER AND DRAIN PIPES UNDER LAVATORIES. 27. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 28. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27" AND 80" ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. OBJECTS MOUNTED AT OR BELOW 27" ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT. FREESTANDING OBJECTS MOUNTED ONPOST OF PYLONS MAY OVERHANG 12" MAXIMUM FROM 27" TO 80" ABOVE THE GROUND SURFACE OR FINISHED FLOOR. 29. ABRUPT CHANGES IN LEVEL EXCEEDING 4" ADJACENT TO WALKS, SUCH AS PLANTERS OR FOUNTAINS, EXCEPT BETWEEN WALKS AND ADJACENT STREETS OR DRIVES, SHALL BE IDENTIFIED BY 6" HIGH WARNING CURBS PROJECTING AT LEAST 6" ABOVE THE WALK SURFACES EXCEPT WHENA GUARDRAIL OR HANDRAIL IS PROVIDED, NO CURB IS REQUIRED WHEN A GUIDE RAIL IS PROVIDED CENTERED 3" (±1") ABOVE THE SURFACE OF THE WALK OR SIDEWALK. DISABLED ACCESS NOTES CONT'D. 30. IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY AND CURBS OR OTHER ELEMENTS DO NOT SEPARATE THE WALKING SURFACES, THE BOUNDARY SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING, WHICH IS 36" IN WIDTH. THE SURFACE SHALL BE RAISED TRUNCATED DOMES IN A STAGGERED PATTERN WITH A DIAMETER OF NOMINAL 0.9" AT THE BASE TAPERING TO 0.45" AT THE TOP. AHEIGHT OF 0.2" AND A CENTER SPACING OF NOMINAL 2.35". sir \ S MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER ISSUE W W z 0 J LU Z U 0 C/) 0 J LU LL (1) ISSUE DESCRIPTION CONSTRUCTION DRAWING O LLJ D 0) J -J W Z LLJ U 0 (1) CO N DATE 02.22.2017 DRAWN BY: SHEET SCALE RM GENERAL NOTES N.T.S. DEMOLITION NOTES 1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER. 5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES. FINISH NOTES 1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, & FREE OF IRREGULARITIES. DO NOT PROCEED WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 2. REPAIR EXISTING SURFACES TO REMAIN AS REQ'D. FOR APPLICATION OF NEW FINISHES. 3. PROVIDE STRAIGHT, FLUSH, RESILIENT BASE AT CARPETED AREAS AND COVED, TOP SET RESILIENT BASE AT RESILIENT FLOORING, U.N.O. POWER & COMMUNICATION NOTES 1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE LOCATIONS WITH OWNER. 2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATE, AND SECURITY SYSTEMS. 3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMETNS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. 4. VERIFY MOUNTING REQUIREMETNS OF ELECTRICAL, TELEPHONE, AND OTHER EQUIPMENT. 5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. POWER & COMMUNICATION NOTES 6. FOR ROOMS OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH SWITCH CONTROLLING 50% OF LAMPS PER FIXTURE. 7. MOUNT STANDARD WALL OUTLETS, SWITCHES, AND THERMOSTATS AT HEIGHTS REQUIRED BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY W/ CENTERLINE AT +3'-2" ABOVE FINISHED FLOOR. 8. INDICATED DIMENSIONS ARE TO THE CENTERLINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. 9. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL BACK-TO-BACK. 10. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATEDITEMS. PROVIDE ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. 11. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT. 12. ALL INTERIOR LIGHTING SYSTEMS SHALL COMPLY WITH CALIFORNIA ENERGY COMMISSION STANDARDS. ABBREVIATIONS A F ACCES ACOUS AFF AL ALT ANNUNC ANOD APPL ARCH AUTO AVG B ACCESSORY ACOUSTIC(AL) ABOVE FINISHED FLOOR ALUMINUM ALTERNATE ANNUNCIATOR ANODIZED APPLIANCE ARCHITECT(URAL) AUTOMATIC AVERAGE AND BLDG BUILDING BOLLD BOLLARD BD BOARD BLKG BLOCKING BRDLM BROADLOOM BU BUILT UP C CAB CPT CEM CER CLG COATG COILG CONC CONSTR CONT CONTR COV CMU D CABINET CARPET CEMENT(ITIOUS) CERAMIC CEILING COATING COILING CONCRETE CONSTRUCTION CONTINUOUS(ATION) CONTRACT(OR) COVER CONCRETE MASONRY UNIT DBL DEPT DES DET DF DIA DIFF DIM DISP DIV DN DR DSCON DWR E DOUBLE DEPARTMENT DESIGN(ED) DETAIL DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DIVISION DOWN DOLLAR (US CURRENCY) DOOR DISCONNECT DRAWER ELAST ELEC EMBED ENGR ENTR EQ EQUIP EXIST EXP JT EXPS EXT ELASTOMERIC ELECTRICAL EMBEDD(ED)(ING) ENGINEER(ED) ENTRANCE EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXPOSE(D) EXTERIOR FAB FD FE FE&C FHC FIN FLDG FPLC FR FRMG FXD FXTR FLR FURN FWC G FABRICATION FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER AND CABINET FIRE HOSE CABINET FINISH FOLDING FIREPLACE FIRE RAT(ING)(ED) FRAMING FIXED FIXTURE FLOOR(ING) FURNITURE FABRIC WALL COVERING GA GAUGE GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GFRP GLASS FIBER REINFORCED PLASTER GLASS GRAD(E)(ING) GYPSUM GL GR GYP K KIT L KITCHEN LAV LB LT LVLG LVR M LAVATORY POUND BRITISH POUND (CURRENCY) LIGHT LEVELING LOUVER MAX MFD MFR MECH MET MEMB MEZZ MIN MISC MLWK MOIST MOT MTD H MAXIMUM MANUFACTURED MANUFACTURER MECHANICAL METAL MEMBRANE MEZZANINE MINIMUM MISCELLANEOUS MILLWORK MOISTURE MOTOR(IZED) MOUNTED HD HDWD HDWE HM HORIZ HVAC HEAD HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HEATING, VENTILATING, AND AIR CONDITIONING ABBREVIATIONS CONT'D. INFO INSTRUM INSUL INTLK INT INFILTR J INFORMATION INSTRUMENT(ATION) INSULATION INTERLOCK(ING) INTERIOR INFILTRATION JAN JANITOR N NIC NO NTS 0 NOT IN CONTRACT NUMBER NOT TO SCALE ORNA OVFL OVHD OPNG OPR P ORNAMENTAL OVERFLOW OVERHEAD OPENING(S) OPERABLE PTN PEDTR PBD PNL POLYST PORT PREFIN PREFAB PLAM PLAS PLSTC PLYWD PRTECN R PARTITION PEDESTRIAN PARTICLE BOARD PANEL POLYSTYRENE PORTABLE PREFINISHED PREFABRICATED PLASTIC LAMINATE PLASTER PLASTIC PLYWOOD PROTECTION RDR RECES RECPT REF REFL REFR REQ'D RESIS REINF RESIL RFG RM RO READER RECESSED RECEPTACLE REFER(ENCE) REFLECTED REFRIGERATOR REQUIRED RESIST(ANT)(IVE) REINFORCE(D)(ING)(MENT) RESILIENT ROOFING ROOM ROUGH OPENING s SCR SECUR SF SGL SHORG SIM SST STD STL STRFR STRUCT SURF SUSP SYS T SCRIBE SECURITY SQUARE FEET SINGLE SHORING SIMILAR STAINLESS STEEL STANDARD STEEL STOREFRONT STRUCTURAL SURFACE SUSPENDED SYSTEM(S) THK TLT TRAF TRANS TRTD T&G TYP u THICK TOILET TRAFFIC TRANSPARENT TREATED TONGUE AND GROOVE TYPICAL UNDRLAY UNDERLAYMENT UTIL UTILITY U.O.N. UNLESS OTHERWISE NOTED V VEH VERT VIF W VEHICLE VERTICAL VERIFY IN FIELD WI WC WD WDW W/O WT WTRPRF WITH WATER CLOSET WOOD WINDOW WITHOUT WEIGHT WATERPROOFING 1r) (/ '4#4 0\HSS MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING E51 CITY OF TUKWIL FEB Z 8 2017 PERMIT CENTEP A z 0 ELD SOUTHCENTER MALL LL (1) W ISSUE DESCRIPTION CONSTRUCTION DRAWING DRAWN BY: SHEET SCALE (fl W 0 C1) J J 2 W H z LLI 0 0 (n 00 CV SEATTLE, WA 98188 DATE 02.22.2017 RM CONSTRUCTION NOTES N.T.S. A00.02 III=III=III-�- 1=1 11-1 11=111-1 l ................I GRAPHIC SYMBOLS (CONT.) REFLECTED CEILING CONT. SD SMOKE DETECTOR MS D 4 E R STROBE FIRE SPRINKLER SPEAKER MOTION SENSOR ACCESS DOOR SECURITY CAMERA THERMOSTAT LIGHT SWITCH DIMMER SWITCH PROJECTION SCREEN RETURN AIR SUPPLY AIR CIRCULAR DIFFUSER LINEAR DIFFUSER DENOTES EXISTING TO REMAIN DENOTES EXISTING, RELOCATED FIXTURE ELEVATION INDICATIONS STONE BRICK/CONCRETE BLOCK FINISHED WOOD GLASS SECTION INDICATIONS 00 0 00 0 00 c NO„rmO„r 4,;;.•d. W///////1///// • • S'1'' III 111IIIIIIII111111111I SAND OR GROUT EARTH OR NATURAL GROUND POROUS FILL (GRAVEL) STONE CONCRETE BRICK CONCRETE MASONRY UNIT METAL NON-FERROUS ALUMINUM PLYWOOD WOOD (FINISH) WOOD (CONTINUOUS) WOOD (BLOCKING) INTERRUPTED MEMBER INSULATION (LOOSE OR BATT) INSULATION (RIGID) GLASS (LARGE SCALE) GYPSUM BOARD PLASTER WITH LATH ACOUSTICAL TILE CARPET FABRIC WRAPPED PANEL GRAPHIC SYMBOLS (CONT.) POWER & COMMUNICATION CONT. i6 V 0 AV V .:. AV V (o 7) Clv) 17) PP (© AV MS ML CR EH EL ES DR DC KS H IC B IA FLUSH FLOOR HALF DEDICATED FOURPLEXNOICE/DATA FLUSH FLOOR DUPLEX/AVNOICE/DATA FLUSH FLOOR FLOOR FOURPLEXIAVNOICE/DATA FLUSH FLOOR POKE THRU DUPLEX FLUSH FLOOR POKE THRU FOURPLEX FLUSH FLOOR POKE THRU DEDICATED DUPLEX FLUSH FLOOR POKE THRU SEPARATE DUPLEX FLUSH FLOOR POKE THRU DEDICATED FOURPLEX FLUSH FLOOR POKE THRU HALF DEDICATED FOURPLEX FLUSH FLOOR POKE THRU TELEPHONE RECEPTACLE FLUSH FLOOR POKE THRU TELE/DATA RECEPTACLE FLUSH FLOOR POKE THRU DATA RECEPTACLE FLUSH FLOOR POKE THRU NV RECEPTACLE FLUSH FLOOR POKE THRU SYSTEMS PANEL VOICE/DATA INFEED FLUSH FLOOR POKE THRU SYSTEMS PANEL POWER INFEED FLUSH FLOOR POKE THRU DUPLEXNOICE/DATA FLUSH FLOOR POKE THRU FOURPLEXNOICE/DATA FLUSH FLOOR POKE THRU HALF DEDICATED FOURPLEXNOICE/DATA FLUSH FLOOR POKE THRU DEDICATED DUPLEXNOICE/DATA FLUSH FLOOR POKE THRU SEPARATE DUPLEXNOICE/DATA FLUSH FLOOR POKE THRU DEDICATED FOURPLEXNOICE/DATA FLUSH FLOOR POKE THRU DUPLEX/AVNOICE/DATA POWER POLE ELECTRIC PIGTAIL DOOR RELEASE MOTION SENSOR ELECTRO -MAGNETIC LOCK CARD READER ELECTRIC HINGE ELECTRIC LOCKSET ELECTRIC STRIKE DOOR RELEASE DOOR MONITOR CONTACT KEY SWITCH DOOR HOLD OPEN INTERCOM BELL PUSH BUTTON REMOTE DOOR RELEASE BUTTON INTRUSION ALARM REFLECTED CEILING L — J XI -X" X' -X" 0 e v v v EF v ACOUSTICAL CEILING AND GRID MAIN RUNNER FLUORESCENT LIGHT FIXTURE FLOURESCENT LIGHT FIXTURE/EMERGENCY CIRCUIT EXISTING TO BE REMOVED DIRECT/INDIRECT 2X2 FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE FLUORESCENT PENDANT FIXTURE CEILING HEIGHT CHANGE DIMENSION OF CEILING ABOVE FINISH FLOOR CEILING FINISH WALL MOUNTED EXIT SIGN, SHOWS QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) CEILING MOUNTED EXIT SIGN, SHOWS QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) CEILING MOUNTED EXIT SIGN RECESSED DOWNLIGHT ADJUSTABLE DOWNLIGHT RECESSED WALL WASHER TRACK LIGHTING SURFACE MOUNTED LIGHT FIXTURE WALL SCONCE EXHAUST FAN DIRECT/INDIRECT PENDANT MOUNTED FLUORESCENT EMERGENCY BATTERY PACK W/ DUAL HEADS CEILING RECESSED EMERGENCY BATTERY PACK W/ DUAL HEADS MONOPOINTS GRAPHIC SYMBOLS (CONT.) POWER & COMMUNICATION 13 V 0 AV V P 0 V hid V V 13 V V 0 AV V NIN AV V c!) NSF 0 0 AV V) AV V) rale .:. 13 .:. idra V 0 AV V P .:. V V V E R WALL MOUNTED DUPLEX WALL MOUNTED FOURPLEX WALL MOUNTED DEDICATED DUPLEX WALL MOUNTED SEPARATE DUPLEX WALL MOUNTED DEDICATED FOURPLEX WALL MOUNTED HALF DEDICATED FOURPLEX WALL MOUNTED TELEPHONE RECEPTACLE WALL MOUNTED TELE/DATA RECEPTACLE WALL MOUNTED DATA RECEPTACLE WALL MOUNTED AN TROUGH WALL MOUNTED AN RECEPTACLE WALL MOUNTED CABLE TV RECEPTACLE WALL MOUNTED VOICE/DATA JUNCTION BOX WALL MOUNTED ELECTRICAL JUNCTION BOX WALL MOUNTED SYSTEMS PANEL VOICE/DATA INFEED WALL MOUNTED SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR DUPLEX SURFACE MOUNTED FLOOR FOURPLEX SURFACE MOUNTED FLOOR DEDICATED DUPLEX SURFACE MOUNTED FLOOR SEPARATE DUPLEX SURFACE MOUNTED FLOOR DEDICATED FOURPLEX SURFACE MOUNTED FLOOR HALF DEDICATED FOURPLEX SURFACE MOUNTED FLOOR TELEPHONE RECEPTACLE SURFACE MOUNTED FLOOR TELE/DATA RECEPTACLE SURFACE MOUNTED FLOOR DATA RECEPTACLE SURFACE MOUNTED FLOOR AN RECEPTACLE SURFACE MOUNTED FLOOR SYSTEMS PANEL VOICE/DATA INFEED SURFACE MOUNTED FLOOR SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR DUPLEXNOICE/DATA SURFACE MOUNTED FLOOR FOURPLEXNOICE/DATA SURFACE MOUNTED FLOOR DEDICATED DUPLEXNOICE/DATA SURFACE MOUNTED FLOOR SEPARATE DUPLEXNOICE/DATA SURFACE MOUNTED FLOOR DEDICATED FOURPLEXNOICE/DATA SURFACE MOUNTED FLOOR HALF DEDICATED FOU RPLEXNOICE/DATA SURFACE MOUNTED FLOOR DUPLEX/AVNOICE/DATA SURFACE MOUNTED FLOOR FOURPLEX/AVNOICE/DATA SURFACE MOUNTED FLOOR POKE THRU DUPLEX SURFACE MOUNTED FLOOR POKE THRU FOURPLEX SURFACE MOUNTED FLOOR POKE THRU DEDICATED DUPLEX SURFACE MOUNTED FLOOR POKE THRU SEPARATE DUPLEX SURFACE MOUNTED FLOOR POKE THRU DEDICATED FOURPLEX SURFACE MOUNTED FLOOR POKE THRU HALF DEDICATED FOURPLEX SURFACE MOUNTED FLOOR POKE THRU TELEPHONE RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU TELE/DATA RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU DATA RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU AN RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU SYSTEMS PANEL VOICE/DATA SURFACE MOUNTED FLOOR POKE THRU SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR POKE THRU DUPLEXNOICE/DATA SURFACE MOUNTED FLOOR POKE THRU FOURPLEXNOICE/DATA FLUSH FLOOR FLOOR DUPLEX FLUSH FLOOR FOURPLEX FLUSH FLOOR DEDICATED DUPLEX FLUSH FLOOR SEPARATE DUPLEX FLUSH FLOOR DEDICATED FOURPLEX FLUSH FLOOR HALF DEDICATED FOURPLEX FLUSH FLOOR DEDICATED SINGLE FLUSH FLOOR TELEPHONE RECEPTACLE FLUSH FLOOR TELE/DATA RECEPTACLE FLUSH FLOOR DATA RECEPTACLE FLUSH FLOOR AN RECEPTACLE FLUSH FLOOR SYSTEMS PANEL VOICE/DATA INFEED FLUSH FLOOR SYSTEMS PANEL POWER INFEED FLUSH FLOOR DUPLEXNOICE/DATA FLUSH FLOOR DEDICATED DUPLEXNOICE/DATA FLUSH FLOOR SEPARATE DUPLEXNOICE/DATA FLUSH FLOOR DEDICATED FOURPLEXNOICE/DATA DENOTES EXISTING TO REMAIN DENOTES EXISTING, RELOCATED FIXTURE GRAPHIC SYMBOLS CONSTRUCTION 1 2 OFFICE 04F06 COLUMN GRID EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW PARTITION REFERENCE TO PARTITION TYPE NON -RATED FLOOR TO FINISHED CEILING DRYWALL PARTITION NON -RATED FLOOR TO UNDERSIDE OF STRUCTURE ABOVE ELEVATION DATUM POINT ROOM NAME ROOM NUMBER ( XXXXXX ) DOOR NUMBER (WITH SCHEDULE) ALIGN 1 ALIGN WITH ESTABLISHED SURFACES XX KEYNOTE REVISION REFERENCE LOCATION ON ROW WHERE SHOWN DIRECTION OF ELEVATION ROW ON ELEVATION SHEET WHERE SHOWN SHEET WHERE SHOWN DETAIL NUMBER SHEET WHERE SHOWN IFLI2,NW s� IM-.., DESCRIPTION OF SIMILAR OR OPPOSITE FLOOR LEVEL AND AREA OR PHASE AREA TO BE DETAILED FHC CD FEC FVC FA FINISH MILLWORK MILLWORK SCHEDULE TAG (IF USED) FIRE HOSE CABINET FIRE EXTINGUSHER WITHOUT CABINET FIRE EXTINGUSHER CABINET FIRE VALVE WITHOUT CABINET FIRE VALVE CABINET FIRE ALARM PULL WALL FINISH BASE FINISH EXTENT OF FINISH WALL FINISH EXTENT OF FINISH WALL FINISH WAINSCOT FINISH BASE FINISH EXTENT OF FINISH SPECIAL FINISH FLOOR FINISH CHANGE IN FLOOR FINISH MA? 1`,2O L REVIEWED FOR CODE COMPLIANCE APPROVED MAR 142017 City of Tukwila BUILDING DIVISION REUJivLD CITY OF TUKWILA FEB 2 8 20x7 PERMIT CENTER rSS 1 " MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818,886.3257 z 0 J —J 2 w z w 0 0 C/) 0 —J w_ L. C!) w 0) Cfl w (1) J J 2 w z w U 0 (1) 00 CV 00 00 00 CA Q Li" I- Q w (!) ISSUE ISSUE DESCRIPTION DATE CONSTRUCTION DRAWING 02.22.2017 DRAWN BY: SHEET SCALE RM GRAPHIC SYMBOLS AS NOTED A00.03 i DEMO FLOOR PLAN SCALE: 1/4" = 1'-0" ffie + 0 0 0 0® 0 0 0 0 0 x ::- 0 0 0 ® 00s 0 0 0 0 0 0 (E) GYP. B.D. CLG. 8' - 0" A.F.F. (V.I.F) (E) GYP. B.D. CLG. 10' - 0" A.F.F. (V.I.F) (E) GYP. B.D. CLG. 10' - 0" A.F.F. (V.I.F) (E) GYP.B.D. CLG. 12' - 112' A.F.F. (V.I.F) EXIST4ING0 ,REFLECTED CEILING PLAN SCALE: 1/ = 1 - 2 KEYNOTES 1. LEASE LINE. 2. (E) DOUBLE SWING GLASS DOOR ENTRY TO REMAIN. 3. G.C. TO PREPARE (E) WALLS TO RECEIVE NEW FINISHES. PATCH AND REPAIR IF NECESSARY, SEE SHEET A05.01, A11.03 FOR MORE INFO. 4. (E) FLOOR TO REMAIN, G.C. PATCH AND REPAIR IF NECESSARY TO BE IN "LIKE NEW CONDITION". 5. DEMOLISH PORTION OF LOW HEIGHT WALL, PATCH AND REPAIR ALL AREA AFFECTED BY DEMOLISHED PORTION OF WALL. 6. G.0 TO VERIFY LOCATION OF (E) ELECTRICAL PANEL. G.C. TO ENSURE (E) ELECTRICAL PANEL AND ANY ELECTRICAL HARDWARE (TRANSFORMERS IF EXISTING) ARE IN "LIKE NEW" CONDITION. REPLACE PARTS IF NECESSARY. 7. (E) HVAC DIFFUSERS TO REMAIN. PATCH AND REPAIR IF NECESARY. 8. (E) GLAZING TO REMAIN, G.C. PATCH AND REPAIR IF NECESSARY. 9. PREPARE (E) MILLWORK TO RECEIVE NEW FINISH, SEE SHEET A11.03 FOR MORE INFO. 10. UNLESS OTHERWISE NOTED, ALL EXISTING CEILING LIGHTS TO REMAIN, G.C. TO CONFIRM ALL CEILING LIGHTING ARE IN "LIKE NEW CONDITION" PATCH AND REPAIR IF NECESSARY. SHEET NOTES 1. COMPLY W/ APPLICABLE LOCAL, STATE, & FEDERAL CODES & REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY & ENVIRONMENTAL PROTECTION. 2. IF DEMO IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED AREAS © NO COST TO THE OWNER. 3. UNLESS OTHERWISE NOTED, ALL EXISTING CEILING SHALL REMAIN. 4. PROVIDE ADEQUATE PROTECTION OF ADJACENT • SURFACES NOT INCLUDED IN THE DEMOLITION. 5. ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY DESIGNER OF ANY CONFLICTS W/ THE WO 6. EXISTING CONSTRUCTION SHOWN DASHED TO BE DEMOLISHED, U.O.N. 7. PATCH & SKIM COAT EXISTING WALLS TO RECEIVE SPECIFIED WALL FINISH WHERE REQUIRED. 8. ANY DEMO OR REMOVAL INDICATED IS SHOWN I�!®— B REVIEWED FOR -fi@DE COMPLIANCE APPROVED 0\ -SS MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 1� GENERAL TO PROVIDE THE EXTENT OF DEMO & I NOT CONSIDERED A RECORD DRAWING OF EXIS CONDITIONS. 9. SEE STOREFRONT ELEVATIONS FOR ITEMS OF DEMOLITION IN ADDITION TO THOSE CALLED OUT. 11. DEMO ALL ELECTRICAL OUTLETS, FIXTURES FRO VI WALLS DEMOLISHED, AND CONDUIT BACK TO DEMISING WALP ':of Tukwila APPLICABLE. CAP AND TAG IF POSSIBLE TO ASST "lij-DING DIVISION CIRCUIT. 12. ALL THAT ARE NOT BEING REUSED SHALL NOT BE lRECEiVED ABANDONED. ALL UNUSED ITEMS (INCLUDING BUT Y OF TUKWILA LIMITED TO CONDUITS, PIPING, WIRING, EQUIPMENT , HANGERS, DUCTWORK, ETC.) MUST BE REMOVED TO ITSFEB 2 8 2017 POINT OF ORIGIN AND SPACE BROUGHT BACK TO ITS ORIGINAL CONDITION. PERMIT CENTER 13. G.C. TO COORDINATE WITH MALL MANAGEMENT FOR BARRICADE/GRAPHICS REQUIREMENTS ESPECIALLY CLEARANCES WITHIN THE MALL CORRIDOR. BARRICADE DOORS MUST OPEN INWARDS. MAR 1 4 2017 1J -J —J W F— z LL! U 0 U) —J W_ L- Lil ISSUE DESCRIPTION CONSTRUCTION DRAWING O O CO LL! F— (/) J J W z W U 0 O 00 CV DATE 02.22.2017 DRAWN BY: SHEET SCALE RM DEMO PLAN 114" =11-0" 103 i T- 1 1'-5" 1'-0' 105 STORAGE ROOM <102) 1'-2" V.I.P. ROOM 104 CASHWRAP DEMO STATION AREA AREA 2 1 103 1 J 102 1'-2" - PROPOSED FLOOR PLAN 1/4" = 1'-O" SHEET NOTES 1. ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY DESIGNER OF ANY CONFLICTS WITH THE WORK. 2. CONSTRUCT NEW PARTITIONS AS SHOWN ON PLAN. 3. TYPICAL: PATCH & REPAIR ALL SURFACES WHERE WALLS HAVE BEEN REMOVED OR SCARRED OUTSIDE OF DEMOLITION SCOPE OF WORK. 4. REPAIR & SKIM COAT AS REQUIRED ALL EXISTING WALLS TO RECEIVE NEW WALL FINISHES. 5. EXISTING SUB -FLOOR TO BE REPAIRED TO RECEIVE NEW FLOOR FINISHES. PATCH & FILL ALL HOLES. 6. WHERE NEW WORK ADJOINS EXISTING, SUCH NEW WORK SHALL BE PROPERLY INTEGRATED W/ THE EXISTING TO INSURE UNIFORM APPEARANCE. NEW SURFACES SHALL ALIGN W/ EXISTING ADJACENT SURFACE. 7. ALL DRYWALL USED TO BE 5/8" THICK, TYPE "X". 8. G.C. IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. 9. ANY EQUIPMENT, FIXTURES, ETC. THAT TENANT WILL BE REUSING MUST BE REFURBISHED TO "LIKE NEW" CONDITION. 10. ANY EXISTING SYSTEM WITHIN TENANT'S SPACE THAT WILL BE REUSED MUST BE BROUGHT UP TO CURRENT LANDLORD'S STANDARDS AND CODES AT TENANT'S EXPENSE. 14. TENANT'S LEASED PREMISES MUST COMPLY W/ TITLE III OF THE AMERICAN WITH DISABILITIES ACT (ADA). COMPLIANCE WILL INCLUDE, BUT NOT LIMITED TO, THE DESIGN, CONSTRUCTION AND/OR ALTERATION OF THE LEASE PREMISES. UPON COMPLETION OF WORK, TENANT OR TENANT'S ARCHITECT MUST SUPPLY TO LANDLORD A LETTER SATISFACTORY TO LANDLORD, STATING THAT THE LEASED PREMISES HAVE BEEN DESIGNED AND CONSTRUCTED IN ACCORDANCE AND ARE IN COMPLIANCE WITH THE ADA. ROOM SCHEDULE ROOM NO. DESCRIPTION REMARKS 100 ENTRY --- 101 DEMONSTRATION AREA 1 --- 102 DEMONSTRATION AREA 2 --- 103 CASHWRAP AREA SALES AREA. 104 V.I.P. ROOM --- 105 STORAGE ROOM --- 101 3'-0" 2'-10" 7'-6" 4'-3" 113 001 • 101 DEMO STATION AREA 1 Ow) PARTITION LEGEND DOOR SCHEDULE DOOR NO. DESCRIPTION REMARKS DOOR SIZE EXISTING CONSTRUCTION TO REMAIN FINISH REMARKS 100 NEW CONSTRUCTION SEE FLOOR PLAN FOR MORE INFO. 120X72 A EXISTING NON -RATED PARTITION: 7'-6" IN HEIGHT. SEE DETAIL 2 SHEET A05.01 FOR MORE INFO. SWING 1 DOOR SCHEDULE DOOR NO. DOOR TYPE MATERIAL DOOR SIZE HARDWARE GROUP FINISH REMARKS 100 DOUBLE/SWING METAL/GLASS 120X72 A EXISTING EXISTING TO REMAIN. G.C. TO ENSURE PROPER WORKING ORDER AND TO BE IN "LIKE NEW CONDITION" 101 SWING WOOD/GLASS 36X84 B GLASS NEW 102 SWING WOOD 36X84 A PAINT EXISTING TO REMAIN. PAINT P-1. 103 SWING WOOD 36X84 A PAINT EXISTING TO REMAIN. 104 SWING WOOD 36X84 A PAINT EXISTING TO REMAIN. HARDWARE GROUP A - EXISTING TO REMAIN B - NEW - 1 $" THICKNESS. - SINGLE PANEL DOOR. MUST COMPLY WITH EGRESS DOOR NOTES ON THIS PAGE. NOTE: ALL DOORS MUST BE OF COMMERCIAL SOLID WOOD OR METAL FRAMING. HOLLOW RESIDENTIAL GRADE OR "HOME DEPOT" PANELS ARE NOT ALLOWED. 100 ENTRY AREA KEYNOTES 1. NEW LIONESSE SIGN PROVIDED BY OWNER. SEE DET. 4 SHEET A11.03 FOR MORE DETAILS. 2. 6" X 48" FLOATING GLASS SHELVES, G.C. TO V.I.F. EXISTING SPACE FOR GLASS SHELVES DIMENSIONS, SEE SHEET A11.03 FOR MORE DETAILS. 3. G.0 TO EXTEND MILLWORK PIECE TO ALIGN WITH PROPOSED WALL LOCATION. SEE SHEET A11.03 FOR MORE CLARIFICATION. 4. WALL DISPLAY HOOK, HOOK TO BE 10" (D). 5. 30"(W) X 40"(H) LED GRAPHIC. COORDINATE WITH LIONESSE FOR GRAPHIC.SEE SHEET A11.03 FOR MORE INFO. 6. 48"(W) X 30"(H) LED GRAPHIC. COORDINATE WITH LIONESSE FOR GRAPHIC. SEE SHEET A11.03 FOR MORE INFO. 7. (E) CASHWRAP. TO RECEIVE NEW FINISH. SEE DET. 3 SHEET A05.01 FOR MORE INFO. 8. 46" X 24" ISLAND DISPLAY MILLWORK. 9. 15" X 18" PEDESTAL DISPLAY. 10. 46" (W) X 42" (H) WALL MOUNTED MIRROR WITH LED LIGHTING. PROVIDE POWER BEHIND WALL. ALL WIRING TO BE CONCEALED. 11. 14"(W) X 51"(D) SHELF DISPLAY. DOOR NOTES 1. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 2. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. 3. A MINIMUM 24" EXTERIOR STRIKE SIDE CLEARANCE SHALL BE MAINTAINED FOR SINGLE PRIMARY ENTRANCE DOORS; 18" ON THE INTERIOR STRIKE SIDE CLEARANCE; 12" ON THE PUSH SIDE CLEARANCE IF DOOR HAS CLOSER AND LATCH. DOOR AND GATE CLEARANCES SHALL BE DIMENSIONED ON PLANS TO REFLECT THE REQUIRED CLEARANCES. 4. MINIMUM DOOR WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF 32". 5. THRESHOLD SHALL BE NOT MORE THAN 2" HIGH BEVELED AT 2 HORIZONTAL TO 1 VERTICAL TO A VERTICAL MAXIMUM OFY4".. REVIEWEIFFOR CODE COMPLIANCE APPROVED MAR 14 2011 City of Tukwila BUILDING DIVISION 11 RECEIVED CITY OF TUKW LA FE13 2 8 2017 PERMIT CENTER i \ MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 cn w z 0 J J W z W U I-- 0 0 J W_ L- (1) w ISSUE ISSUE DESCRIPTION DATE CONSTRUCTION DRAWING 02.22.2017 DRAWN BY: SHEET SCALE RM PROPSOED PLAN 1/4" =1'-0" A02.01 (E) L (E) 1 (E) I it (E) (E) (E) (E) (E) (E)(7) (E) 44, A+ (E) (E) n (E)n +E) ca) (E)0 43(4, (E) (E) A(E)A (E) 4'-2d (E) (E)0 (E) (E)0 (N) (E) (E) (E) t)t3=I (N) 0(E) ()0 (E) X E) Os0 (E) ()0 (E) ((E) ( )® 0 (N) (E) (E) ()0 11 (E)0 (E)0 ()0 (E)0 (E) (E) 13 (E)0 (E)0 ID ()0 (E)0 (E)0 ()0 (E) GYP. B.D. CLG. 8' - 0" A.F.F. (V.I.F) KEYNOTES 1. INSTALL NEW CHANDELIER. G.C. TO ENSURE ALL WIRING TO BE CONCEALED OR TO BE TAUGHT AGAINST HANGING WIRE. BOTTOM OF CHANDELIER TO BE 7'-0" ABOVE FINISHED FLOOR. OWNER PROVIDED. 2. (E) CEILING TO REMAIN. G.C. TO PATCH AND REPAIR IF NECESSARY. 3. (E) EXISTING RETURN AND SUPPLY DIFFUSERS. G.C.TO ENSURE PROPER WORKING CONDITION. 4. (E) THERMOSTAT LOCATION TO REMAIN. 5. SWITCH TO CEILING CHANDELIER IN SALES AREA. (E) GYP. B.D. CLG. 10' - 0" A.F.F. (V.I.F) REFLECTED CEILING PLAN 1/4" = 1'-0" SHEET NOTES 1. ALL INTERIOR LIGHTING SYSTEMS SHALL COMPLY WITH LOCAL ENERGY STANDARDS. 2. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. 3. ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY DESIGNER OF ANY CONFLICTS WITH THE WORK. 4. ALL LIGHTING FIXTURES SHOWN ON PLAN ARE EXISTING OR RELOCATED UNLESS OTHERWISE NOTED. 5. ALL LIGHT FIXTURES MARKED WITH 'E' ARE EXISTING TO REMAIN AND 'R' FOR RELOCATED FIXTURES. 6. ALL FIRE/LIFE/SAFETY EQUIPMENT AND SPRINKLER HEADS SHALL REMAIN. RE -POSITION AS REQUIRED FOR NEW LAYOUT AND AS REQUIRED BY CODE. 7. ALL EXIT LIGHTING TO BE CONNECTED TO BUILDING'S EMERGENCY ELECTRICAL CIRCUIT SYSTEM OR BATTERY PACKS AS REQUIRED BY CODE. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ONSITE GENERATOR. 8. TENANT CEILING SHALL BE FINISHED WITH FLAT WHITE FINISH, UNLESS OTHERWISE NOTED. 9. CONTRACTOR TO RE -USE EXISTING HVAC AND REDISTRIBUTE AND ADD NEW AS REQUIRED FOR NEW LAYOUT, CODES AND BUILDING STANDARD. 10. GENERAL CONTRACTOR TO VERIFY EXIT SIGN LOCATIONS WITH FIRE INSPECTOR. 11. REWORK EXISTING FIRE/LIFE SAFETY DEVICES AND PROVIDE NEW AS REQUIRED TO COMPLY WITH LOCAL CODE AND NEW LAYOUT. THIS WORK SHALL BE FILED UNDER SEPARATE PERMIT. 12. VERIFY EXISTING THERMOSTAT LOCATIONS WITH LIONESSE. 13. DUE TO UNFORESEEN OBSTRUCTIONS IN THE CEILING, LIGHTING LAYOUT MAY BE ALTERED IN THE FIELD. 14. GENERAL CONTRACTOR TO PROVIDE AIR RETURN OPENINGS AND GRILLS AT FULL HEIGHT PARTITIONS TO ALLOW AIR CIRCULATION. 15. EXISTING SPEAKER AND AUDIO SYSTEM CONNECTIONS SHALL REMAIN. G.C. TO MAKE APPROPRIATE ADJUSTMENTS PER NEW LAYOUT. COORDINATE WITH LIONESSE. 16. G.C. TO VERIFY ALL CEILING HEIGHTS IN FIELD. 17. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL PROVIDE POWER TO ALL EMERGENCY LIGHTS MARKED ON PLAN. 18. IF NOT ALREADY EXISTING, TENANT MUST PROVIDE A SEALED PARTITION ABOVE THE STOREFRONT TO SEPARATE THE COMMON AREA CEILING FROM THE TENANT'S SPACE. (SHALL BE RATED IF REQUIRED BY CODE AND ALL PENETRATION SHALL COMPLY AND BE LABELED WITH THE REQUIRED NFPA RATING.) 19. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE LANDLORD'S STRUCTURE, FLOOR DECK, OR ROOF DECK. YOU MAY ATTACH, NON DESTRUCTIVELY, TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE TENANT SPACE. WHEN ATTACHING TO LANDLORD'S STRUCTURE, DO NOT DRILL, WELD, SCREW, OR SHOOT INTO STRUCTURE. ALTERNATIVE METHODS OF ATTACHMENT ONLY, NOTHING TO DAMAGE LANDLORD'S BASE BUILDING STRUCTURE. TENANT SHALL PROVIDE SIGNED AND SEALED STRUCTURAL DRAWINGS, BY A STRUCTURAL ENGINEER WITH LEGALLY ACTIVE REGISTRATION AS INDICATED BY ALL JURISDICTIONAL REQUIREMENTS, FOR ALL STRUCTURAL MODIFICATIONS FOR LANDLORD RECORDS. 20. ANY LANDLORD EQUIPMENT, COMPONENT, AND / OR SERVICE FEEDING OTHER TENANT(S) THAT ARE EXISTING IN THE SPACE MUST RE0I VISIBLE AND ACCESSIBLE TO THE LANDLORD. TENANT SHALL INSTALL ACCESS PANELS AS REQUIRED TO MAINTAIN ACCESS. ACCESS PANELS SHALL BE LABEL TO PROPERTY IDENTIFY SYSTEM, COORDINATE WITH MALL OPERATIONS. 21. WESTFIELD REQUIRES ALL TENANTS TO USE LANDLORD'S REQUIRED CONTRACTOR FOR ALL SPRINKLER WORK. REFER TO SPRINKLER COMMENTS FOR FURTHER REQUIREMENTS. (E) GYP. B.D. CLG. 10' - 0" A.F.F. (V.I.F) (E) GYP.B.D. CLG. 12' - 112" A.F.F. (V.I.F) NOTES: • (N) INDICATES NEW CEILING FIXTURE. • (E) INDICATES EXISTING CEILING FIXTURE. • ALL (E) SUPPLY AND RETURN DIFFUSERS TO REMAIN UNLESS IN CONFLICT WITH NEW WALLS. IF IN CONFLICT RELOCATE THE LOCATION. • ALL (E) TRACK LIGHT TO REMAIN UNLESS IN CONFLICT WITH PROPOSED DESIGN LAYOUT. IF IN CONFLICT REMOVE. LIGHTING SCHEDULE SYMBOL DESCRIPTION LAMPS WATTS COUNT REMARKS t-® CEILING MOUNTED EXIT SIGN --- 26 4 1 (N) G.C. TO VERIFY THE QUANTITY OF (E). REPAIR AND REPLACE IF NECESSARY. CHANDELIER CFL 60 2 LOCATE AT 7'-6" A.F.F. 0.0. OF MIDDLE STATION, OWNER SUPPLIED 0 LEGEND 10 e{ E R FLUORESCENT LIGHT FIXTURE FLOURESCENT LIGHT FIXTURE/EMERGENCY CIRCUIT UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE FLUORESCENT PENDANT FIX1URE CEILING HEIGHT CHANGE DIMENSION OF CEILING ABOVE FINISH FLOOR DENOTES EXISTING TO REMAIN DENOTES EXISTING, RELOCATED FIXTURE WALL MOUNTED EXIT SIGN, SHOWS QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) CEILING MOUNTED EXIT SIGN, SHOWS QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) 1--® CEILING MOUNTED EXIT SIGN o RECESSED DOWNLIGHT -a ADJUSTABLE DOWNLIGHT e RECESSED WALL WASHER SURFACE MOUNTED LIGHT FIXTURE WALL SCONCE EXHAUST FAN CEILING EMERGENCY BATTERY PACK W/ DUAL HEADS MS 0 SMOKE DETECTOR STROBE FIRE SPRINKLER SPEAKER MOTION SENSOR ACCESS DOOR THERMOSTAT LIGHT SWITCH RETURN AIR SUPPLY AIR CIRCULAR DIFFUSER MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818, 886.3200 F: 818.886.3257 w cn cn w z 0 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER W z W U 0 (1) 0 —J W_ LL (1) W ISSUE DESCRIPTION CONSTRUCTION DRAWING DRAWN BY: SHEET SCALE O co w (1) J J W z W U 0 t!) O CO00 CV DATE 02.22.2017 1, RM REFLECTED CEILING PLAN 1/4"=1'-0" i A04.01 L KEYNOTES: (E) FLOOR TILE TO REMAIN, G.C. PATCH ANS REPAIR IF NECESSARY. 2. (E) VERTICAL PANEL BETWEEN RECESSED MILLWORKS UNIT TO BE PAINT P-1. REFER TO SHEET A11.03. 3. SEE ELEVATIONS FOOR MORE DETAILS. 4. P1 - WHITE PAINT. 5. (E) MILLWORK TO BE PAINT P2- HIGH GLOSS BLACK PAINT. SEE ELEVATIONS FOR MORE DETAILS. 1 i1 FINISH PLAN 1/4" = 1'-0" 3"-0° CASHWRAP FINISH 1" = 1'-0" LEGEND WALL FINISH BASE FINISH EXTENT OF FINISH WALL FINISH .— EXTENT OF FINISH FLOOR FINISH CHANGE IN FLOOR FINISH NOTE: (E) MILLWORK SHELVES TO BE PAINT P-2 AND P-1 FOR INTERIOR PANEL SHELF DIVISIONS. SEE ELEVATIONS FOR MODE DETAILS. 5/8" GYP. BOARD. 1/2" SCHLUTER STRIP, OCCURS IN EVERY OTHER VERTICAL TILE. T2 - 12' X 24' WHITE GLOSSY TILE, SEE A05.01 FOR MORE INFO. 1/8' GROUT. THIN -SET MORTAR. MAX 3/16' THICKENS 3 5/8° METAL STUD . 1/2' SCHLUTER STRIP, OCCURS IN EVERY OTHER VERTICAL TILE. T2 - 12' X 24' WHITE GLOSSY TILE, SEE A05.01 FOR MORE INFO. 1/8" GROUT. THIN -SET MORTAR. MAX 3/16' THICKENS 3 5/8° METAL STUD . 1/2' SCHLUTER STRIP, OCCURS IN EVERY OTHER VERTICAL TILE. 5/8' GYP. BOARD. T2 - 12' X 24' WHITE GLOSSY TILE, SEE A05.01 FOR MORE INFO. 3/8" 0 P.A.F EXPANSION ANCHOR WITH 2" EMBED WALL TILE DETAIL 1" = 1'-0" SHEET NOTES P1 o u. CV � P1 STANDARD FINISH SCHEDULE NO. DESCRIPTION MANUFACTURER STYLE/PATTERN COLOR REMARKS WC1 WALL PAPER RONALD REDDING OOH LA LA COLLECTION RRD 1158W OWNER PROVIDED P1 PAINT BENJAMIN MOORE 00-118 SNOWFALL WHITE PROVIDE FLAT FINISH AT CEILING. GC SUPPLIED. P2 PAINT --- --- HIGH GLOSS BLACK HIGH GLASS FINISH, G.C. SUPPLIED. T1 EXISTING TILE --- --- --- --- T2 PORCELAIN TILE SUPPLIER: INTERNATIONAL TILE AND STONE SUPER WHITE N/A 12" X 24" INSTALL ON WALL PER MANUFACTURE'S RECOMMENDATIONS, GROUT FINISH: GRAY, OWNER SUPPLIED 1. ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY DESIGNER OF ANY CONFLICTS WITH THE WORK. 2. STOREFRONT GLASS TO BE CLEANED UPON COMPLETION OF CONSTRUCTION AS A PART OF THE GENERAL CONSTRUCTION CLEAN-UP. 3. PREP ALL EXISTING GYP. BOARD WALLS TO RECEIVE NEW WALL FINISH. 4. TYPICAL THROUGHOUT, SKIM COAT ALL EXISTING PARTITION TO REMAIN. SEE ELEVATION FOR MORE INFORMATION ON THE SCOPE OF WORK ON FINISHES. 5. ALL COLOR AND MATERIALS SHALL MEET ALL CODE REQUIREMENTS FOR FLAME SPREAD AND SMOKE DEVELOPMENT FACTORS. 6. LIONESSE TO VERIFY WITH THE SITE TENANT COORDINATOR IF WATERPROOFING MEMBRANE BENEATH BATHROOM FLOORING EXIST. INSTALL WATERPROOFING MEMBRANE IF NON-EXISTENT. 7. ALL REUSED MATERIALS AND EQUIPMENT MUST BE REFURBISHED "LIKE NEW" CONDITION. 8. THE SURFACE OF FLOORS SHALL BE SLIP RESISTANT. WHEN TESTED IN ACCORDANCE WITH ASTM C102B TEST PROCEDURE FOR COEFFICIENT OF FRICTION, TILE MUST ACHIEVE A WET AND DRY VALUE OF NOT LESS THAN 0.60. PRIOR TO THE INSTALLATION OF THE FLOOR COVERING, A WRITTEN STATEMENT FROM THE FLOORING MANUFACTURER MUST BE SUBMITTED TO THE BUILDING DIVISION, COMMUNITY DEVELOPMENT DEPARTMENT STATING THAT THE PRODUCT TO BE INSTALLED MEETS CURRENT INDUSTRY STANDARDS FOR SLIP RESISTANCE." 9. THRESHOLD SHALL BE NOT MORE THAN 2" HIGH BEVELED AT 2 HORIZONTAL TO 1 VERTICAL TO A MAXIMUM OF 4". 10. TENANT SHALL PROVIDE A FINISH SAMPLE BOARD OR SIMILAR TO THE LANDLORD FOR APPROVAL. 11. ALL FLOORING TRANSITIONS MUST BE SMOOTH AND FLUSH. THE USE OF PLASTIC, VINYL, OR RUBBER TRANSITIONS STRIPS IS STRICTLY PROHIBITED. TENANTS MUST UTILIZE A HARD SURFACE TRANSITION. 12. TENANT IS REQUIRED TO INSTALL A WATERPROOF MEMBRANE IN ALL WET AREAS (RESTROOMS, KITCHENS, FOOD SERVICES, ETC...) OF THE SPACE. TENANT SHA L, 30 MIL POLYETHYLENE CLEAVAGE MEMBRANE (EQUAL TO NOBLE SEAL TS) I ,T� L PER MANUFACTURERS RECOMMENDATIONS AND ANSI A108. MEMBRANE MU EXTENDED UP THE WALL A MINIMUM OF 4" OR EQUAL TO THE HEIGHT OF THE BASE. 13. NO RUBBER OR VINYL BASE IS PERMITTED IN THE SALES AREA OF THE PREMISES. 14. SLAB REQUIREMENTS: 14.1. SLAB ON GRADE: TENANT'S GENERAL CONTRACTOR SHALL ADVISE THE OPERATION TEAM PRIOR TO ANY SLAB MODIFICATIONS OR REMOVAL. TENANT GC SHALL VERIFY THAT WORK SHALL NOT CONFLICT WITH ANY EXISTING STRUCTURAL, UTILITY, OR OTHER UNDER -SLAB CONDITION. (NONDESTRUCTIVE VERIFICATION MAYB REQUIRED.) ANY DAMAGE OR DOWNTIME CAUSED BY TENANT'S WORK SH REPAIRED AND REIMBURSED AT TENANT'S EXPENSE. 14.2. ELEVATED SLABS: TENANT'S GENERAL CONTRACTOR SHALL ADVISE THE OPERATIONS TEAM PRIOR TO ANY SLAB MODIFICATION OR REMOVAL. IF A ELEVATED SLAB IS TO BE MODIFIED ANYWAY (DRILLED, CORED, OR PENET TENANT SHALL PROVIDE STAMPED AND CERTIFIED DRAWINGS BY A LICENS STRUCTURAL ENGINEERED CERTIFIED IN THE LOCAL JURISDICTION. ALL PENETRATIONS SHALL BE CORE BORED ONLY. SAW CUTTING, JACK HAMM , AND TRENCHING IS STRICTLY PROHIBITED. ALL PENETRATIONS SHALL BE SLEE9 0\ MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 z 0 J W z W U D 0 CO CDJ W LL (/) W ISSUE DESCRIPTION CONSTRUCTION DRAWING SEATTLE, WA 98188 DATE 02.22.2017 REVIEWED F E COM'LI APPROVE y MAR 14 20 TED), D City of Tuk BUILD! DJ SEALED, FIRE STOPPED, AND WATERPROOFED. THE PENETRATION SLEEVE SHALL 8 �� EXTEND A MINIMUM 4" ON EITHER SIDE OF THE SLAB AND BE LABELED WITH THE FEB- REQUIRED NFPA RATING. TENANT GC SHALL VERIFY THE WORK SHALL NOT PERMIT CENT CONFLICT WITH ANY EXISTING STRUCTURAL, UTILITY, OR OTHER UNDER -SLAB CONDITION. (NONDESTRUCTIVE VERIFICATION MAYBE REQUIRED.) ANY DAMAGE OR DOWNTIME CAUSED BY TENANT'S WORK SHALL BE REPAIRED AND REIMBURSED AT TENANT'S EXPENSE. OF TU iia J RM FINISH PLAN 1/4"=1'-0" A05.01 5� I 1'-5" 1'-0' 1'-2" (E) 31-0" 3'-0" jr 2'-10" 7'-6" 4'-3" MMI WPM CDFURNITURE/POWER & COMMUNICATION PLAN 1/4" = 1 '-O" KEYNOTES: 1. EXISTING ELECTRICAL PANELS AND TRANSFORMER TO REMAIN.G.0 TO VERIFY THE LOCATION. 2. PROVIDE POWER OUTLET FOR LED MIRRORS. G.C. V.I.F. IF EXISTING CAN BE USED IF NOT G.C. PROVIDE AS RE❑UIRED. 3. EXISTING LOCATION FOR CASHWRAP AND GROUT OUTLET. VERIFY WORKING ORDER PATCH AND REPAIR IF NECESSARY. 4. 6" X 45" (APPROXIMATELY) FLOATING GLASS SHELVES. G.0 TO V.I.F. EXISTING OPEN SPACE DIMENSIONS TO DETERMINE GLASS SHELVING SIZES. 5. PROVIDE POWER FOR PREFABRICATED GRAPHIC LIGHT BOX. G.C. V.I.F. IF EXISTING CAN BE USED, IF NOT G.C. PROVIDE AS RE❑UIRED. 6. LED GRAPHIC. COORDINATE WITH LIONESSE FOR GRAPHIC. SEE ELEVATIONS FOR DIMENSION. 7. V.I.P TREATMENT BED 8. 46" X 24" ISLAND DISPLAY. OWNER PROVIDED. 9. 15" X 18" PEDESTAL DISPLAY. OWNER PROVIDED. 10. 14" X 51" SHELF UNIT FRONT LEFT SIDE. 11. WALL DISPLAY HOOKS, HOOK TO BE 10"(D) 12. SOFA. OWNER PROVIDED 13. 2'-0"(W) X 4'-0"(D) DEMO TABLE. 14. (E) CASHWRAP. 15. NEW LIONESSE CASHWRAP SIGN. SEE DET. 4 SHEET A11.03 FOR MORE INFO. 0 0 0 SHEET NOTES 1. VERIFY E❑UIPMENT SPECIFICATIONS, POWER AND INSTALLATION RE❑UIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. 2. MOUNT STANDARD WALL OUTLETS, SWITCHES, AND THERMOSTATS AT HEIGHTS RE❑UIRED BY LOCAL GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTERLINE AT 113'-2" ABOVE THE FINISHED FLOOR. 3. INDICATED DIMENSIONS ARE TO THE CENTERLINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. 4. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE ONE-PIECE TYPE GANG COVER PLATES UNLESS OTHERWISE NOTED. 5. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT OR SIMILAR IDENTIFYING MARK. 6. CONTRACTOR TO NOTIFY LIONESSE OF ANY CONFLICTS WITH THE WORK. 7. ALL DEDICATED OUTLETS SHALL HAVE NO MORE THAN (3) DUPLEX OUTLETS PER CIRCUIT. 10. ABANDONED ELECTRICAL CONDUIT, J -BOXES, WIRING FROM UNDER FLOOR CAVITY AND AT PARTITIONS, WIRING AND CONDUITS THAT ARE BURIED OR OTHERWISE INACCESSIBLE ARE TO BE REMOVED TO POINT OF ORIGIN. IN SUCH CASES, CONTRACTOR SHALL PULL ALL WIRE FROM THE CONDUIT, CUT BACK CONDUIT FLUSH WITH FINISHED FACE AND FILL ALL OPENINGS. 11. THE CONTRACTOR SHALL CLEARLY LABEL THE CIRCUIT BREAKER SWITCHES. 12. SEE REFLECTED CEILING PLAN FOR ADDITIONAL POWER REDUIREMENTS. 13. FINAL LOCATIONS FOR POWER/TEL./DATA OUTLETS SHALL BE CONFIRMED BY THE TENANT 0 TENANT'S VENDORS PRIOR TO BEGINNING WORK. CONTACT LIONESSE TO COORDINATE. 14. G.C. TO OBTAIN APPROVAL FROM WESTFIELD ON-SITE TENANT MANAGER FOR TRENCHING PRIOR TO PROCEEDING WITH WORK. 0 8'-9" LEGEND v v g 7 Q 0 EN V E R WALL MOUNTED DUPLEX WALL MOUNTED FOURPLEX WALL MOUNTED TELEPHONE RECEPTACLE WALL MOUNTED TELE/DATA RECEPTACLE WALL MOUNTED DATA RECEPTACLE WALL MOUNTED AN RECEPTACLE WALL MOUNTED CABLE TV RECEPTACLE WALL MOUNTED VOICE/DATA JUNCTION BOX WALL MOUNTED ELECTRICAL JUNCTION BOX SURFACE MOUNTED FLOOR DUPLEXNOICE/DATA SURFACE MOUNTED FLOOR FOURPLEXNOICE/DATA FLUSH FLOOR DUPLEXNOICE/DATA DENOTES EXISTING TO REMAIN DENOTES EXISTING, RELOCATED FIXTURE LANDLORD ELECTRICAL NOTES 1. TENANT/TENANT ENGINEER ARE RE❑UIRED TO PERFORM A FIELD SURVEY TO VERIFY ALL EXISTING CONDITIONS. 2. TENANT/TENANT ARCHITECT/TENANT ENGINEER ARE RESPONSIBLE TO REVIEW ELECTRICAL SYSTEMS, PANELS, TRANSFORMERS, VOLTAGE, PROVISIONS SPECIFIC TO THIS SPACE AND RECONCILE TO TENANT RED UIREMENTS. 3. ELECTRICAL SERVICE IS EITHER EXISTING OR STUBBED BY LANDLORD (CONDUIT AND PULL STRING), ANY FURTHER ELECTRICAL RE❑UIREMENTS MUST BE PROVIDED BY TENANT AT TENANT EXPENSE, UNLESS OTHERWISE NOTED IN LEASE. 4. REFER TO THIS MALLS TENANT CRITERIA MANUAL FOR GENERAL GUIDELINES AND INFORMATION REGARDING ELECTRICAL SERVICE. 5. NO POWER POLES OR SURFACE MOUNTED ELECTRICAL CHASES MAY BE USED IN A WESTFIELD MALL ALL POWER MUST BE PROPERLY RUN IN WALLS, OR TRENCHED IN SLAB. ALL SAW CUTTING OF SLAB AND / OR TRENCHING SHALL BE STRICTLY COORDINATED WITH THE LANDLORD AND FACILITIES MANAGER. GC SHALL VERIFY AND BE RESPONSIBLE FOR DETECTION AND ANY SUBSE❑UENT DAMAGE TO UNDERGROUND CONDUIT AND WIRING THAT MAY EXIST BELOW SLAB. 6. THE MALL FACILITIES MANAGER HAS THE AUTHORITY TO MA DECISIONS AND FIELD CHANGERS IN ACCORDANCE WITH W TENANT CRITERIA AND ANY SPECIFIC MALL OPERATIONAL IS 7. MALL FEATURES SUCH AS SPEAKERS, RECEPTICLES, FIRE S S BES, y-) DIFFUSERS, ETC. MUST BE MAINTAINED AND RELOCATED AS REDUIREDY INTO TENANT STOREFRONT. REVIEW SPECIFICS WITH THE MALL FACILITIES MANAGER PRIOR TO START OF CONSTRUCTION. 8. IT IS TENANT RESPONSIBILITY TO DESIGN AND INSTALL MECHANICAL / REVIEWED FOIA ELECTRICAL / PLUMBING / STRUCTURAL IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 9. NO PVC MAY BE USED ABOVE GROUND. CODE COMPLIANCE APPROVED MAR 14 2017 10. ALL MECHANICAL, ELECTRICAL, PLUMBING AND ROOFTOP WORK MIST BE REVIEWED WITH ALL FACILITIES MANAGER PRIOR TO START OF WORK. NO EXCEPTIONS. City of Tukwila 11.TENANT IS RESPONSIBLE FOR PROVIDING CONDITIONED (COOLED / BUILDING DIVISION HEATED) AIR. THIS MALL PROVIDES CHILLED WATER AND ALL TENANTS MUST DESIGN THEIR SYSTEM TO CONNECT PROPERLY TO LL SYSTEM. ONLY THE MALLS APPROVED CONTRACTOR CAN MAKE FINAL RECEIVED CONNECTIONS TO LL CHILLED WATER. REVIEW MALL CONSTRUCTIOUITY OF TUKWIL;� MANUAL AND TENANT CRITERIA MANUAL FOR DETAILS. 12.IF TENANT IS CONSIDERING RE -USE OF EXISTING AIR HANDLER IN SPACTe3 2 8 2017 44411 0\HSSH MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 w cn w z 0 J J 2 UJ z W U O Cn 0 W L F-- (/) W O O W I-- (1) J J 2 W z W 0 O C/) 00 CV 00 00 00 r O Q 5 Lir i'- F - Q W Cn SUE ISSUE DESCRIPTION DATE CONSTRUCTION DRAWING 02.22.2017 DRAWN BY: CONTACT MALL FACILITIES MANAGER TO VERIFY THAT MALL WILL AL _ =MIT CENTER RE -USE OF UNIT. UPGRADES AND REFURBISHMENT ARE RE❑UIRED BRING ALL EXISTING UNITS TO 'LIKE NEW CONDITION. TENANT MUST PROVIDE WRITTEN PROOF TO MALL THAT THE UNIT WAS PROPERLY SERVICED AND ASSESSED DURING TIME OF CONSTRUCTION. 1 RM SHEET FURNITURE/POWER PLAN SCALE 1/4'1=11-0" A06.01 L— B.O. INTERIOR CLG. OF MALL CORRIDOR 15 '- 5" A.F.F. (V.I.F) B.O. STOREFRONT BULKHEAD 12 '-112 " A.F.F. (V.I.F) B.O. ENTER DOOR 10 '- 0" A.F.F. (V.I.F) JfrJ, 5-5" 6'-0' EXISTING STOREFRONT SCALE: 3/8"=1'-0" ct 0 z U: > 0 EXISTING STOREFRONT SECTION SCALE: 3/8"=1'-0" )J, FINISHED FLOOR 11 1 NN 18'-O8" 5'-82" (BRAKE METAL HORIZONTAL SIZE) 6-8" (BRAKE METAL HORIZONTAL SIZE) 5'4 (BRAKE METAL HORIZONTAL SIZE) 0 0 O 6'-28"�� 5' e" I 6'4 / / Q 0 L— / / \\ i // 0 \T ,4", 5'-5" lie 6'-0" j4'j 5'-38 4" 1-7 STOREFRONT SCALE: 3/8"=1'-0" 00 CO z N rTN 3 SCALE: 3/8" PROPOSED STOREFRONT SECTION ='- 4 B.O. INTERIOR CLG. OF MALL CORRIDOR 15 '- 5" A.F.F. (V.I.F) B.O. STOREFRONT BULKHEAD 12 '-114 " A.F.F. (V.I.F) B.O. ENTER DOOR 10 '- 0" A.F.F. (V.I.F) FINISHED FLOOR 2 REFER TO SIGN SHOP DRAWINGS FOR MORE INFORMATION KEYNOTES 1. NEW LIONESSE REVERSE PAN CHANNEL LETTERING, HALO LIT. LETTERING TO BE 3" IN DEPTH. SEE SHEET A11.02 FOR MORE INFORMATION. 2. LEASE LINE. 3. (E) STOREFRONT DOOR TO REMAIN. 4. (E) GLAZING TO REMAIN, G.C. PATCH AND REPAIR IF NECESSARY. 5. (E) GLASS FRAMING FINISH TO REMAIN, PATCH AND REPAIR IF NECESSARY. 6. (N) BLACK SEMI GLOSS .090" BRAKE METAL FINISH TO BE INSTALLED ON 2" BACKER BOARD. G.C. TO REMOVE EXISTING TILE PRIOR TO INSTALLATION. FRONT FACE OF BRAKE METAL TO BE FLUSH WITH EXISTING TILE ON NEUTRAL PIERS. 7. EXISTING TILE ON TOP OF STOREFRONT TO BE REMOVED. TILE LOCATED ON TOP OF NEUTRAL PIERS TO REMAIN. EXISTING NEUTRAL PIER CHANNELS TO STAY AS -IS. ALL NEW TENANT TO STOREFRONT FINISHES TO ABUT EXISTING CHANNEL. G.C. TO PROTECT TENANT CONSTRUCTION AND REPAIR TO AS -NEW CONDITION. 9. BRAKE METAL SEAM LINE. BRAKE METAL TO HAVE 1" FOLD TO CREATE A STRAIGHT SEAM. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER n11- OO?fl LIONESSE MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 w cn w z 0 J J w z w 0 F-- 0 0 —J w_ LL" w ISSUE DESCRIPTION CONSTRUCTION DRAWING C, Cfl w (1) _i —J w z w 0 0 00 CV co co cTO rn ui H Q w DATE 02.22.2017 1, DRAWN BY: SHEET SCALE RM STOREFRONT ELEVATIONS 3/8"=1'-0" A11.01 REVERSE PAN CHANNEL LETTERING 5'-911 2 A11.02 NOTE: VERIFY IN FIELD ALL DIMENSIONS TO ENSURE THAT SIGN PROPORTION MEETS APPROVED ELEVATION 120V/20AMP CIRCUIT REQ'D BY OTHERS 1" SPACER #10 SHEET MTL. SCREWS W/ 12" ALUM. SPACERS AS REQ'D 16" LEXAN BACKS .090 ALUMINUM FACES CLASS II SHIELDED CABLE (18 AWG SUPPLY WIRE) WHITE LED MODULES .063 ALUMINUM RETURNS FINSIH: BLACK NO WEEP HOLES ALLOWED. ALL SIGN LETTERS TO BE INDIVIDUALLY MOUNTED TO STOREFRONT. ElIcer9pD STOREFRONT MAIN SIGN ELEVATION SC LIONESSE MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 R VIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 ity of Tukwila U LDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER 1 SSCALETOR,FRO1 0NT SIGN SECTION 2 0911 . 3 { ISSUE z 0 O J C) J � < W 2 ~ W W (i) co W Q O) ~ W OH tO W E- U ~ J = W W f— ISSUE DESCRIPTION CONSTRUCTION DRAWING DATE 02.22.2017 voi DRAWN BY: SHEET SCALE RM STOREFRONT SIGN DETAILS 3°=1'-0° A11.02 INTERIOR FRONT WALL ELEVATION SCALE: 3/8” = 1'0" 1 4 M i0 M 0 0000eoc000 0 0 0 4 0 N /2" 2 RIGHT SIDE WALL ELEVATION SCALE: 3/8" = 1'-0" CO E55 CASH WRAP FRONT ELEVATION SCALE: 3/8" = 1'-0" 1 5'-2" 2'-4" NOTE: G.C. TO V.I.F. ALL DIMENSIONS OF MILLWORK PRIOR TO PROCURING GLASS SHELVING. 0 4 LEFT SIDE WALL ELEVATION SCALE: 3/8" = 1'-0" 3'-4" 4'-0" 3'-8" / V.I.P LEFT SIDE WALL ELEVATION SCALE: 3/8" = l'-0" d3. 4/ "4"4"4"4'�4""4""'�3l //// //4/4/ M 0 0 0 0 m `° fV „,, , \:,\ • • \\\\. \\\\ ..\. \ \\\\ ,... \ \ ' _ \ \.,... C \\N, ,,, \ • N‹,\, \:\ i \ \ \ /\ \... „,,..\ \, 0 / / 0 \, '(:.ii \ _ \ \_ `0\ \ 0 - (V INTERIOR FRONT WALL ELEVATION SCALE: 3/8” = 1'0" 1 4 M i0 M 0 0000eoc000 0 0 0 4 0 N /2" 2 RIGHT SIDE WALL ELEVATION SCALE: 3/8" = 1'-0" CO E55 CASH WRAP FRONT ELEVATION SCALE: 3/8" = 1'-0" 1 5'-2" 2'-4" NOTE: G.C. TO V.I.F. ALL DIMENSIONS OF MILLWORK PRIOR TO PROCURING GLASS SHELVING. 0 4 LEFT SIDE WALL ELEVATION SCALE: 3/8" = 1'-0" 3'-4" 4'-0" 3'-8" / V.I.P LEFT SIDE WALL ELEVATION SCALE: 3/8" = l'-0" d3. 4/ "4"4"4"4'�4""4""'�3l //// //4/4/ M 0 0 0 0 m `° fV \ ' _ \ M C 0 '(:.ii \ _ \ \_ `0\ \ 0 - (V 0 M II M1 V.LALE:P 3/8" = 1'-0" BACK WALL ELEVATION SC 7 0 0 NOTE: G.C. TO V.I.F. ALL EXISTING DIMENSIONS KEYNOTES 0 `° fV ' . 1. WC1- WALL PAPER - RRD 1158W RONALD REDDING OOH LA LA COLLECTION 2. P1- PAINT: BENJAMIN MOORE SNOWFALL WHITE; OC118 LEVEL 5 FINISH. 3. NEW WALL PANEL. 4. 6" (W) X 48"(D) FLOUTING GLASS SHELVES, G.C. TO V.I.F. EXISTING OPEN SPACE FOR GLASS SHELVES DIMENSIONS. 5. P2- HIGH GLOSS BLACK PAINT 6. 48"(W) X 30"(H) LED GRAPHIC COORDINATE WITH LIONESSE FOR GRAPHIC. 7. 30"(W) X 40" (H) LED GRAPHIC COORDINATE WHIT LIONESSE FOR GRAPHIC. 8. 36"(H) X 60" (W) GRAPHIC. COORDINATE WITH LIONEESE FOR GRAPHIC. 9. 46"X42" LED MIRROR, OWNER PROVIDED 10. WALL DISPLAY HOOK, HOOK TO BE 10"(D). 11. (E) MIRROR TO REMAIN, G.C. TO PATCH AND REPAIR IF NECESSARY. 12. (E) GLAZING TO REMAIN, G.C. PATCH AND REPAIR IF NECESSARY. 13. (E) METAL GLAZING BASE. 14. (E) ENTRY DOOR TO REMAIN AS IS. 15. LIONESSE LOGO: 8" BLACK ACRYLIC LETTERING. 16. 63" (W) X 8" (D) FLOUTING WALL WOOD SHELVES. 17. T2 - 12" 24" SUPER WHITE TILE, OWNER SUPPLIER, INSTALL PER MANUFACTURE'S RECOMMENDATION, 1/2" POLISHED CHROME SCHLUTER TO RUN BETWEEN TILE HORIZONTALLY EVERY 24". 18. NEW MILLWORK PIECE TO ALIGN WITH EXTERIOR PORTION OF EXISTING MILLWORK FACE. FINISH WITH BLACK PAINT. 19. LOCATION OF NEW PARTIAL HEIGHT WALL. V.I.P RIGHT SIDE WALLELEVATION V.I.P ENTRANCE ELEVATION " SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1-0 r)i REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City ©f Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER LIONESSE MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 w w z 0 —J w z w U Z 0 (1)0 J W u_ W ISSUE ISSUE DESCRIPTION DATE 1 CONSTRUCTION DRAWING 02,22.2017 DRAWN BY: SHEET SCALE IJ INTERIOR ELEVATIONS 318"=1'-0" A11.03 ,44 g Poo i 044 beauty bar 4,441014,, CI tV REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER MAZAL ENTERPRISE 20255 CORISCO ST. CHATSWORTH, CA 91311 T: 818.886.3200 F: 818.886.3257 O J CO a) J < W 1.1.J 2 I5 (01)w W 0 00 V) W ...i - < 0) LLI _ 2 Q i—H D W z -J 0 w � ooQ J = W W E— LL 0 W wumail 0 (/) 5. O o co N ISSUE DESCRIPTION CONSTRUCTION DRAWING DATE 02.22.2017 1