Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0052 - DAVID'S BRIDAL - REFIXTURE
DAVID'S BRIDAL 17740 SOUTHCENTER PKWY D17-0052 Parcel No: Address: 0 City of Tukwila O Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049005 Permit Number: 17740 SOUTHCENTER PKWY Project Name: DAVID'S BRIDAL Issue Date: Permit Expires On: D17-0052 4/27/2017 10/24/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC/KIMCO 3333 NEW HYDE PARK STE 100 PROPERTY TAX DEPARTMENT, NEW HYDE PARK, FL, 11042 JASON KIRBY 176 E HIGHLAND AVE, CLERMONT, FL, 34711 NATIONAL RETAIL SERV GROUP INC 8987 E TANQUE VERDE RD , TUCSON, AZ, 85749 N DTIORS832J7 DAVID'S BRIDAL 1001 WASHINGTON ST, CONSHOHOCKEN, PA, 19428 Phone: (407) 469-5599 Phone: (800) 921-7503 Expiration Date: 4/27/2019 DESCRIPTION OF WORK: REFIXTURE/REFRESH EXISTING DAVID'S BRIDAL STORE Project Valuation: $15,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $683.31 Occupancy per IBC: M Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: C/I.C.0 Date: 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe mi and agree to the conditions attached to this permit. Signature: Print Name:`y Date ✓ / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 0 0 9: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 7: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 8: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: Maintain fire extinguisher coverage throughout. 11: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 12: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 14: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 15: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 16: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 17: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 13: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 18: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 22: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 20: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 19: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 24: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 25: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 26: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Building Permit No. Ii W 2_ Project No. Date Application Accepted Date Application Expires: f 41 / f_ (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 2623049079 17740 Southcenter Pkwy., Tukwila, WA 98188 Suite Number: Floor: 1 Tenant Name: David's Bridal PROPERTY OWNER Name: Jason Kirby Name: David's Bridal City: Clermont State: FL Zip: 34711 Address: 1001 Washington St. Email: jason.kirby@expeditepermit.com City: Conshohocken State: pA Zip: 19428 CONTACT PERSON — person receiving all project communication - Name: Jason Kirby Address: 176 E Highland Ave. City: Clermont State: FL Zip: 34711 Phone: (407) 469-5599 Fax: (407) 469-3499 Email: jason.kirby@expeditepermit.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Address: 461 From Rd. City: Paramus State: NJ Zip: 07652 Phone: (407) 469-5599 Fax: (407) 469-3499 City: State: - Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I l.does Revised: August 2011 bh New Tenant: El Yes ® ..No ARCHITECT OF RECORD' Company Name: Sargenti Architects Architect Name: Robert Sargenti Address: 461 From Rd. City: Paramus State: NJ Zip: 07652 Phone: (407) 469-5599 Fax: (407) 469-3499 Email: jason.kirby@expeditepermit.com ENGINEER OF RECORD Company Name: Don Penn Consulting Engineer Engineer Name: Don Penn Address: 1301 Solana Blvd. Bld 1 #1420 City: Westlake State: TX Zip: 76262 Phone: (407) 469-5599 Fax: (407) 469-3499 Email: jason.kirby@expeditepermit.com LENDER/BOND ISSUED (required for projects $5,000 or greater perRCW 19.27.095) Name: David's Bridal - Tenant Address: 1001 Washington St. City: Conshohocken State: PA Zip: 19428 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 15,000 Existing Building Valuation: $ 9,841,000 Describe the scope of work (please provide detailed information): Qe -rule€ l Qt Pz & e1U S`vt u (ro ball: zS Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required! Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes I No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ▪ None CIOther (specify) No Change Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Z No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWortns-Applications On Line1201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per = IBC Type of Occupancy per IBC 1St Floor 12,945 12,945 0 0 IIB Mercantile 2nd Floor 0 0 0 0 0 0 3`°Floor 0 0 0 0 0 0 Floors 0 thru 0 0 0 0 0 0 0 Basement 0 0 0 0 0 0 Accessory Structure* 0 0 0 0 0 0 Attached Garage 0 0 0 0 0 0 Detached Garage 0 0 0 0 0 0 Attached Carport 0 0 0 0 0 0 Detached Carport 0 0 0 0 0 0 Covered Deck 0 0 0 0 0 0 Uncovered Deck 0 0 0 0 0 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes I No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ▪ None CIOther (specify) No Change Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Z No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWortns-Applications On Line1201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Extremely minor refresh of the existing David's Bridal Store. Replace fixtures, finishes, etc. No Mechanical or Plumbing Work Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ..• .Tukwila ❑... Water District #125 El ...Water Availability Provided Sewer District ® ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline El ... Val ley View El .. Renton ❑ ... Sewer Availability Provided El .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ❑ .: Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way El ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards 0 ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Traffic Impact Analysis ❑ ...Hold 1 -harmless — (SAO) ❑ ...Hold Harmless — (ROW) El .. Right-of-way Use - Profit for less than 72 hours El .. Right-of-way Use — Potential Disturbance 111.. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut El .. Looped Fire Line ❑ ...Permanent Water Meter Size... 0 ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ 1.7 17 11 77 11 WO # WO # WO # Private ❑ Private 0 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation El .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ® ...Water ® ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Existing Account Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Existing Account City State Zip Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I VE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJUR . T• LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW �R:O _ .. i ' ZED AGENT: Signature: _ Date: 03/07/2017 Print me: Jason Kirby Day Telephone: (407) 469-5599 Mailing Address: 176 E Highland Ave Clermont FL 34711 H:\Applications\Forms-Applications On Line \201I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh - City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY ( PAID $428.54 D17-0052 Address: 17740 SOUTHCENTER PKWY Apn: 3523049005 $428.54 Credit Card Fee $12.48 Credit Card Fee R000.369.908.00.00 0.00 $12.48 DEVELOPMENT $396.46 PERMIT FEE R000.322.100.00.00 0.00 $391.96 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11374 R000.322.900.04.00 0.00 $19.60 $428.54 Date Paid: Thursday, April 27, 2017 Paid By: LISA OSWALT Pay Method: CREDIT CARD 04732A Printed: Thursday, April 27, 2017 1:08 PM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila Receipt Number R11075 DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $404.92 D17-0052 Address: 17740 SOUTHCENTER PKWY Apn: 3523049005 $254.77 DEVELOPMENT $254.77 PLAN CHECK FEE R000.345.830.00.00 0.00 $254.77 EL17-0202 Address: 17740 SOUTHCENTER PKWY Apn: 3523049005 $150.15 ELECTRICAL $143.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $143.00 TECHNOLOGY FEE $7.15 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11075 R000.322.900.04.00 0.00 $7.15 $404.92 Date Paid: Tuesday, March 14, 2017 Paid By: TEAM K5 CONSTRUCTION Pay Method: CHECK 16251 Printed: Tuesday, March 14, 2017 12:23 PM 1 of 1 CRWsYsnms INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: i 1.) s eta( Sprinklers: y.e5 Type of Inspection: F;N14-(---- Address: - Suite#: / �d PlI/i Contact Person: Special Instructions: t Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: y.e5 Fire Alarm: VC, e , i ,__ .--J/ , ar _ . ( I Occupancy Type: M !V r i r -i i' to O 1.. - Needs Shift Inspection: Sprinklers: y.e5 Fire Alarm: VC, Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:? S- Date: /fr/-- Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director October 9, 2017 Randy Jones National Retail Services Group 8987 E Tanque Verde Rd — Suite 309-410 Tucson, AZ 85749 RE: Request for Extension #1 Permit Number D17-0052 Dear Mr. Jones, This letter is in response to your written request for an extension to Permit D17-0052. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through April 24, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. D17-0052 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 0 Bill Rambo From: Jerry Hight Sent: Friday, October 6, 2017 12:59 PM To: Bill Rambo Subject: FW: Bldg Permit Extension - D17-0052 Can you process this? Thank you Jerry E Hight MCP Building Official I City of Tukwila 6300 Southcenter BLVD, Suite 100 I Tukwila, WA 98188 T: 206/431-3675 I F: 206/431-3665 Jerry.Hight@TukwilaWA.gov [2017] http://www.TukwilaWA.gov . IqC FONStVC The City of opportunity, the community of choice. **My incoming and outgoing email messages are subject to public disclosure requirements perICW 42.56 ** From: Randy Jones [mailto:Randy.Jones@gonrsg.com] Sent: Thursday, October 5, 2017 4:14 PM To: Jerry Hight <Jerry.Hight@TukwilaWA.gov> Subject: Bldg Permit Extension - D17-0052 Jerry — thanks again for your time on the call today. As discussed, we respectfully request: that this building permit be extended in order for us to schedule final inspections and address any potential issues during closeout. Please let me know if you need anything else from me. Again, thanks. RJ FISG Randy Jones Chief Operating Officer National Retail Services Group Cell: 702-275-1046 RECEIVED CITY OF TUKWILA OCT 062011 PERMIT CENTER Request for Extension # I Current Expiration Date: 10`Z/-4-1 Extension Request: (� / Approved for I v Q days i Denied (provide explanation) 1 Signature/Initials 8/31/2017 4 O City of Tukwila Department of Community Development JASON KIRBY 176 E HIGHLAND AVE CLERMONT, FL 34711 RE: Permit No. D17-0052 DAVID'S BRIDAL 17740 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/24/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/24/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0052 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 UPEAMIT COORD COPY p PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0052 DATE: 03/15/17 PROJECT NAME: DAVID'S BRIDAL SITE ADDRESS: 17740 SOUTHCENTER PKWY Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 74 r7 Building Division N//- -340- r7 Public Works tom to() 0A1 MSt6- Oin 3--)61-i «ars Fire Prevention Structural !Till El Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 03/16/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: (iJz fOc DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) 04/13/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 NATIONAL RETAIL SERV GROU C Home Espanol Loots Search L&I Page 1 of 2 A -Z Index Help My I.8z1 Safety & Health Claims & Insurance Workplace Rights Trades & Licensing CWashington'State Department of ,% Labor & Industries NATIONAL RETAIL SERV GROUP INC Owner or tradesperson OSWALT, LISA MARIE Principals OSWALT, LISA MARIE, MEMBER WA UBI No. 603 051 477 8987 E TANQUE VERDE RD STE 309-410 TUCSON, AZ 85749 800-921-7503 Business type Corporation License S Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NATIORS832J7 Effective — expiration 04/27/2017— 04/27/2019 Bond Western Surety Co Bond account no. 63173764 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/27/2017 04/23/2017 Expiration date Until Canceled Insurance ............................... United States Fire Insurance C $1,000,000.00 Policy no. 5439981726 Received by L&I Effective date 04/27/2017 09/25/2016 Expiration date 09/25/2017 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .......................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ......................................................... No license violations during the previous 6 year period. Workers' comp Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603051477&LIC=NATIORS832J7&SAW= 4/27/2017 NATIONAL RETAIL SERV GROI0X INC No active workers' comp accounts during the p ...sous 6 year period. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603051477&LIC=NATIORS832J7&SAW= 4/27/2017 DavID ,TE, <Wr BRIDAL PA<WAY SUPER CE 17740 SOUTHCE\TR P TU<WILA WA 58188 TU<WILA, WA STOKE #168 COv PA\Y DRECTM Y TENANT CONTACT TITLE/POSITION PHONE FAX EMAIL DAVID'S BRIDAL 1001 WASHINGTON STREET CONSHOHOCKEN, PA. 19428 DAVID'S BRIDAL 1001 WASHINGTON STREET CONSHOHOCKEN, PA. 19428 TODD O'ROURKE CONSTRUCTION CONTACT (610) 662-6753 torourke@dbi,com JUUA MAllA STORE PLANNING MANAGER (610) 943-6796 jmazza@dbi.com ARCHITECT CONTACT TITLE/POSITION PHONE FAX EMAIL SARGENT] ARCHITECTS 461 FROM ROAD, SECOND FLR PARAMUS, NJ 07652 FRANCES TEMPLE -WEST PROJECT MANAGER (215) 482-1950 ftemple-west@sargarch.com COMPANY LISTING CONTACT TITLE/POSITION PHONE FAX EMAIL SHERWIN WILLIAMS SHELLY BEEKLY PAINT (215) 806-3579 shellybeekly@sherwin.com T.C. MILLWORK INC. 3433 MARSHALL LANE BENSALEM, PA 19020 JOE CULLEN FIXTURES - CASHWRAP (267) 223-1233 (215) 245-4729 joecWfcm illwork. com KRG ENTERPRISERS, INC 9901 BLUE GRASS ROAD PHILADELPHIA, PA 19114 FRANK GUETENS FIXTURES (215) 708-2811 (215) 335-2448 fguetens@krgenterprises.com FLOORS USA WHOLESALE INC. 555 S. HENDERSON RD. KING OF PRUSSIA, PA 19406 (FOR DAVID'S BRIDAL USA AND CAN) SCOTT EARLBAUM ENTRY MAT & WALL BASE SOLE SUPPLIER NO SUBSTITUTIONS (610) 757-2000 (610) 757-2005 se@floorsusa.com LOEB ELECTRIC 1800 E 5TH AVE COLUMBUS, OH CHRIS GIBSON LIGHTING FIXTURES (614) 358-4924 (614) 246-4503 chris.gibson@loebelectric.com SCOPE OF WM< 1. TGC TO COORDINATE WITH LOEB LIGHTING THE RETROFIT OF EXISTING UGHTING INCLUDING SALES & BOH AREAS. 2. TGC TO INSTALL 2X4 LIGHTING RETROFIT 3. TGC TO REMOVE AND DISPOSE OF EXISTING CASH WRAP AND ALL OF ITS COMPONENTS IN THEIR ENTIRETY AND INSTALL NEW AS INDICATED IN DRAWINGS. COORDINATE ELECTRICAL 4. TGC TO REMOVE EXISTING WELCOME PODIUM AND INSTALL NEW WELCOME DESK AS INDICATED IN DRAWINGS. TGC TO EXTEND POWER/DATA FROM PODIUM TO LOCATION OF NEW WELCOME DESK. 5. TGC TO REMOVE EXIS11NG DISPLAY CASEWORK AS INDICATED. 6. TGC TO INSTALL NEW OUTRIGGERS AS INDICATED. 7. TGC TO REMOVE ALL CARPETING IN ITS ENTIRETY, INCLUDING WALL BASE AND ADHESIVES. 8. TGC TO INSTALL NEW CARPETING AND VINYL BASE, AS INDICATED ON DRAWINGS. 9. TGC TO REMOVE ALL SLATWALL AND REPLACE WITH ACCESSORY PANELS AS INDICATED. 10. TGC TO INSTALL NEW FIXTURES AS INDICATED. 11. TGC TO REPAIR, PREPARE AND PAINT ALL SALES AND CUSTOMER AREA WALLS INCLUDING, BUT NOT LIMITED TO, SHOW WINDOWS, CORRIDORS, TOILET ROOMS AND HALLWAYS. ALTERATIONS AND RECEIVING AREAS WILL NOT BE PAINTED. REFER TO FINISH SCHEDULE FOR PAINT INFORMATION. 12. TGC TO REPAIR, PREPARE AND PAINT ALL DRESSING & FITTING ROOMS. 13. TGC TO REMOVE AND REINSTALL EXISTING DRESSING ROOM HOOKS TO FACILITATE PROPER FINISHING 14. TGC TO REPLACE ANY MISSING OR DAMAGED DRESSING ROOM HOOKS. 15. TGC TO REMOVE EXISTING CORNER GUARDS ALONG WITH BASE PLATES. WALLS ARE TO BE REPAIRED AND PREPARED FOR NEW FINISHES. 16. TGC TO INSTALL NEW CORNER GUARDS, SANS BASE PLATES, AND REINSTALL EXISTING WALL BUMPERS AND ENDCAPS IN PLACE. 17. TGC TO REMOVE AND DISPOSE OF EXISTING DRESSING & FITTING ROOM MARKETING FRAMES, PATCH WALLS TO FINISH CONSISTENT WITH ADJACENT SURFACES. 18. TGC TO REMOVE EXISTING DRESSING ROOM NUMBERS. 19. TGC TO INSTALL NEW DRESSING ROOM NUMBERS AS INDICATED ON THE DRAWINGS 20. TGC TO REMOVE AND DISCARD EXISTING ALTERATIONS AND BOH CURTAINS. TGC TO INSTALL NEW CURTAINS RE -USING EXISTING HARDWARE. 21. TGC TO INSTALL SPIDER TRACK AT STOREFRONT AS INDICATED ON THE DRAWINGS 22. TGC TO INSTALL BABY CHANGE TABLES IN EACH TOILET ROOM WHERE INDICATED ON THE DRAWINGS 23. TGC TO REMOVE AND DISPOSE OF THE FLOWER GIRL FIXTURES AS INDICATED ON THE DRAWINGS 24. TGC TO REPLACE STAINED/DAMAGED CEILING TILE 25. TGC TO DEMO EXISTING TOILET ROOM FINISHES AND ACCESSORIES AND UPGRADE TO NEW PROTO. PLUMBING FIXTURES ARE TO REMAIN FOR REUSE. 26. TGC TO COORDINATE WITH ATLAS SIGN ON THE INSTALLATION OF THE NEW EXTERIOR SIGN. RE -CONNECT TO EXISTING ELECTRICAL OUTLET. 27. TGC TO COORDINATE WITH ATLAS SIGN ON THE INSTALLATION OF NEW MONUMENT SIGN. 28. TGC TO REMOVE EXISTING ADA DRESSING ROOM LOCKSET IN PREPARATION FOR NEW LOCKSET HARDWARE. 29. TGC TO PROVIDE 120V OUTLET AND PRIVACY LOCKSET FOR LACTATION ROOM (ADA DRESSING ROOM) AS INDICATED ON THE DRAWINGS. 30. AT COMPLETION OF PROJECT. T.G.C. TO TAKE PHOTOS AND VIDEO WALK-THROUGH OF ENTIRE SPACE AND SCOPE OF WORK. <EYV AP 2 3 4 5 6 7 8 -Y \OT IS I EXISTING FLOOR FINISHES TO REMAIN. T.G.C. TO REMOVE AND DISCARD EXISTING MARKETING FRAMES AND DRESSING ROOM NUMBERS T.G.C. TO REMOVE EXISTING DRESSING ROOM NUMBERS I T.G.C. TO REMOVE AND DISCARD EXISTING ALTERATIONS AND BOH CURTAINS. T.G.C. TO RETAIN EXISTING HARDWARE FOR RE -USE FOR INSTALL OF NEW CURTAINS. I DEMO EXISTING SPIDERTRACKS. PRESERVE "BU IILRFLY" CLIPS FOR REUSE. I EXISTING T.R. ACCESSORIES, & FINISHES TO BE REMOVED & DISCARDED. T.G.C. TO REPAIR & PREPARE NEW SURFACES FOR NEW FINISHES. REFER TO SHEET RFS4.0 FOR MORE INFORMATION. FT.G.C. TO REMOVE AND DISCARD EXISTING TOILET ROOM SCONCES AND PREPARE FOR NEW. [-T.G.C. TO REMOVE & REPLACE EXISTING DOOR LOCKSET. T.G.C. TO REMOVE AND DISPOSE OF EXISTING FLOWER GIRL FIXTURE. L� I T.G.C. TO REMOVE AND REPLACE ANY EXISTING STAINED CEILING TILES. 11 I RETROFIT 2X4 PRISMATIC LENS WITH 2X4 VOLUMETRIC AND REPLACE ALL WITH NON FLUORESCENT LIGHT FIXTURES AND ELECTRICAL BY LOEB LIGHTING UNDER SEPARATE CONTRACT WITH DB. 9 12 13 T.G.C. TO COORDINATE WITH SIGN CO. ON REMOVAL, FACADE REPAIR/REFINISH, & INSTALLATION OF NEW SIGN. I EIFS CONTRACTOR TO REPAIR AND APPLY A NEW FINISH SKIM COAT PAINTED TO MATCH EXISTING COLOR AFTER REMOVAL OF EXISTING EXTERIOR SIGN BY ATLAS SIGN UNDER SEPARATE CONTRACT WITH DB. 14 15 16 17 (T.G.C. TO REMOVE AND REPLACE EXISTING CORNER GUARDS PER PLAN. REFER TO DETAIL A/RFS2.0. I EXISTING BUMPER GUARDS TO REMAIN. DEMO CASHWRAP AND BACKWRAP IN ITS ENTIRETY. T.G.0 TO PREPARE SURFACES FOR NEW FIXTURES AND ELECTRICAL.TGC TO REMOVE EXISTING GWB SOFFIT ABOVE CASHWRAP. PATCH AND REPAIR GRID FOR LIKE -NEW APPEARANCE. T.G.C. TO REMOVE AND DISCARD EXISTI1 PRESENTATION CHAIRS. I TGC TO REMOVE EXISTING FLOWER GIRL LLAGE FRAME AND HOLD FOR RELOCATION. El! EXISTING CURTAIN, ROD AND HARDWARE REMOVED. PATCH AND REPAIR WALL TO MAKE LIKE I T.G.C. TO REMOVE FIXTURE AND HOLD FOf, :CATION. 18 20 21 22 23 24 25 26 T.G.C. TO REMOVE & DISCARD EXISTING FIX -i COMPLETELY. T.G.C. TO REPAIR WALLS, DOORS AND TRIM I FAINT. REFER TO FINISH SCHEDULE ON SHEET RFS IT.C.C. TO REPAIR EXISTING DRYWALL CRAG- THROUGHOUT STORE AND PREPARE WALL ACES FOR LEVEL 5 FINISHES. I EXISTING PLATFORM TO REMAIN. I TGC TO REMOVE EXISTING "OLEG CASSINI" LETTERS FROM SOFFIT. ITGC TO REMOVE ALL EXISTING SLATWALL AND ACCESSORY DRAWER FIXTURES. 27 I EXISTING TOILET ROOM PLUMBING FIXTURES TO REMAIN. DAVID'S BRIDAL 17740 SOUTHCENTER PARKWAY TUKWILA, WA 98188 NORTH SHEET I\DEX SHEET DESCRIPTION REVISION ARCHITECTURAL RFS1.0 2017 DAVID'S BRIDAL REFRESH PROGRAM -DEMO RFS2.0 2017 DAVID'S BRIDAL REFRESH PROGRAM -PROPOSED RFS3.0 2017 DAVID'S BRIDAL REFRESH PROGRAM -ELEVATIONS RFS4.0 2017 DAVID'S BRIDAL REFRESH PROGRAM-T.R. ELEVATIONS E1.0 ELECTRICAL PLAN APPL CA3LE CODES G -\-RAL \OT -S 1 TGC TO REMOVE ALL EXISTING CARPETING, WALK -OFF MATT, ADHESIVES AND ADJACENT WALL BASE IN THEIR ENTIRETY, UNLESS NOTED OTHERWISE. 2. TGC TO RELOCATE EXISTING DRESSING ROOM HOOKS AS REQUIRED PER DETAILS. NAME MvENDVIENTS WASHINGTON STATE BUILDING CODE W/ LOCAL AMENDMENTS AND SUPPLEMENTS THE INTERNATIONAL BUILDING CODE, 2015 W/ LOCAL AMENDMENTS AND SUPPLEMENTS THE INTERNATIONAL EXISTING BUILDING CODE, 2015 INTERNATIONAL MECHANICAL CODE, 2015 W/ LOCAL AMENDMENTS AND SUPPLEMENTS W/ LOCAL AMENDMENTS AND SUPPLEMENTS INTERNATIONAL FIRE CODE, 2015 W/ LOCAL AMENDMENTS AND SUPPLEMENTS UNIFORM PLUMBING CODE, 2015 W/ LOCAL AMENDMENTS AND SUPPLEMENTS ICC ANSI A117 1-09 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE. 2015 W/ LOCAL AMENDMENTS AND SUPPLEMENTS NATIONAL ELECTRICAL CODE W/ LOCAL AMFNDMFNTS AND SUPPLEMENTS W/ LOCAL AMENDMENTS AND SUPPLEMENTS GE\HAL IOU EVE \TS A\ D \OTES 1. TGC TO COORDINATE WITH THE LANDLORD FOR THE PLACEMENT OF DUMPSTER AND STORAGE CONTAINERS 2. TGC TO INCLUDE IN ITS BASE BID THE COST TO PROVIDE A FORKLIFT AND PALLET JACK FOR THE RECEIVING AND UNLOADING OF DAVID'S BRIDAL PROVIDED MATERIALS. FORKLIFT MUST HAVE THE ABILITY TO LIFT AND MOVE PALLETS OF AT LEAST 8' IN LENGTH 3. ANY DAMAGED OR MISSING ITEMS TO BE REPORTED TO THE DAVID'S BRIDAL CONSTRUCTION REPRESENTATIVE IMMEDIATELY UPON RECEIPT OF SAID ITEMS. 4. TGC TO TAKE FULL RESPONSIBILITY OF ALL MATERIALS STORED ON OR OFF SITE IMMEDIATELY UPON RECEIPT 5. TGC TO PROVIDE BONDED AND INSURED SECURITY SERVICE FOR ALL OVERNIGHT WORK. SECURITY IS TO BE PRESENT FROM TIME OF STORE CLOSING FOR THE DAY UNTIL THE ARRIVAL OF MANAGEMENT PERSONNEL THE FOLLOWING MORNING. DELAYS CAUSED BY FAILURE OF SECURITY SERVICE TO ARRIVE ON TIME WILL BE THE RESPONSIBILITY OF THE TGC 6. TGC TO PROVIDE ALL PROTECTION NECESSARY TO PROTECT ALL PRODUCT, DISPLAYS, FIXTURES, ETC. THROUGHOUT THE COURSE OF THE PROJECT 7. TGC TO TEMPORARILY REMOVE FIXTURES FOR INSTALLATION OF CARPET AND PAINT AS REQUIRED AND RELOCATE AS INDICATED ON THE DRAWINGS 8. ALL FIXTURES ARE TO BE INSTALLED ON TOP OF FINISHED CARPET 9. TGC TO INSTALL VINYL BASE ON ALL EXPOSED WALLS EXCEPT MIRRORED WALLS AND AREAS WHERE THERE ARE BUILT IN FIXTURES 10. CARPET TO BE PROFESSIONALLY INSTALLED WITH SHARP BUTTING SEAMS 11. TGC TO BE RESPONSIBLE FOR DISPOSAL OF ALL CARPET, PACKING MATERIALS AND DEBRIS CREATED BY THE PROJECT. DAVID'S BRIDAL AND LANDLORD DUMPSTERS ARE NOT TO BE USED 12. STORE OPERATIONS WILL BE RESPONSIBLE FOR THE REMOVAL AND RESET OF ALL WALL HANG PRODUCT ONLY 13. TGC TO REMOVE AND RESET ALL FLOOR FIXTURES FOR CARPET AND COVE BASE INSTALLATION AND PAINTING AS INDICATED ON THE DRAWINGS 14, FOR FIXTURES NOT SHOWN ON DRAWINGS CONTACT DAVID'S BRIDAL CONSTRUCTION REPRESENTATIVE FOR FURTHER INSTRUCTION 15. TGC TO EXERCISE CAUTION IN THE REMOVAL OF EXISTING VINYL BASE. ANY AND ALL REPAIRS TO WALLS RESULTING FROM COVE BASE REMOVAL WILL BE THE RESPONSIBILITY OF THE TGC 16. TGC TO INSURE THAT THE STORE IS CLEAN AND READY FOR CUSTOMER SHOPPING EACH MORNING BY 10:00 AM. 17. TGC TO DUST/CLEAN TOPS OF ALL 8' WALLS PRIOR TO PAINTING 18. WITHIN SEVEN (7) DAYS OF NOTIFICATION OF CONTRACT AWARD, THE SUCCESSFUL BIDDER MUST PROVIDE TO DAVID'S BRIDAL A DETAILED PHASING PLAN FOR EACH STORE INDICATING WHAT WORKS WILL BE PROPOSED FOR EACH NIGHT FOR THE DURATION OF THE PROJECT. SHOE CLOSET DRESSING poo7 1112? 23 DRESSNG ROOMS 00' 10 ALTERATIONS I 01s I CORRIDOR I 005 STAGING OFFICE TO 3 TYP.6 014 013 DRESSING ROOMS 10 11 10 11 22 DRESSING ROOMS 23 DRESSING ROOMS I 007 _I - DRESSING ROOMS TYP.4 10� -- -- --_III SALES I 003 I DRESSES TYP.3 BRIDAL SELECTION ENTRY 14 TYP.3 X 12 13 22 23 SHOW WINDOW VESTIBULE SHOW WINDOW 22 23 rNREVISIONS No changes sha!I b' rnpcle to the scope of work withol.�i prior approval of Tukwila Bi ldin Division. OTE: Revisions will rcquiio ,a ri5- plan submittal and may inU(udf.) c.01ditian .l p!arl f`3vf ."iits.s . [2E01 riFIT:: FOR: LervICCharical IaQ �1CC:fiCc'?f Plumbing Ltd Gas Piping LE COPY Permit No, b11-- 00 99- Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel opy a7 9 ditions is acl�howled jod: By. Oa_ ).),(,(}-t ,', Date: �•,/ /-/-7 / /'7 'City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 4 2017 PERMIT CENTER LLJ Ly., 0 Ce u, - J I a �o N U M W o O)I-U • o= U ,0' c .0 = OC Q, N J co Q w V) •JLf)� a N > SEAL ROBERT STATE 0 DRAWINGS ISSUED DATE COMMENTS CCI r m CHECKED BY: FTW. U- 0 CD <- (-- 1 J � � m � n O CO 12 r--1 I REVIEVVED?Q )DE COMPLTAINIpq APPROVED APRR02017 City of -"IEwila BUILDING i (VISION 1 0 min mom mionn wig= - - 1 - _L - _ - _ - L ENTRY 14 TYP.3 X 12 13 22 23 SHOW WINDOW VESTIBULE SHOW WINDOW 22 23 rNREVISIONS No changes sha!I b' rnpcle to the scope of work withol.�i prior approval of Tukwila Bi ldin Division. OTE: Revisions will rcquiio ,a ri5- plan submittal and may inU(udf.) c.01ditian .l p!arl f`3vf ."iits.s . [2E01 riFIT:: FOR: LervICCharical IaQ �1CC:fiCc'?f Plumbing Ltd Gas Piping LE COPY Permit No, b11-- 00 99- Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel opy a7 9 ditions is acl�howled jod: By. Oa_ ).),(,(}-t ,', Date: �•,/ /-/-7 / /'7 'City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 4 2017 PERMIT CENTER LLJ Ly., 0 Ce u, - J I a �o N U M W o O)I-U • o= U ,0' c .0 = OC Q, N J co Q w V) •JLf)� a N > SEAL ROBERT STATE 0 DRAWINGS ISSUED DATE COMMENTS CCI r m CHECKED BY: FTW. U- 0 CD <- (-- 1 J � � m � n O CO 12 r--1 I REVIEVVED?Q )DE COMPLTAINIpq APPROVED APRR02017 City of -"IEwila BUILDING i (VISION 1 0 min mom mionn wig= mit ENTRY 14 TYP.3 X 12 13 22 23 SHOW WINDOW VESTIBULE SHOW WINDOW 22 23 rNREVISIONS No changes sha!I b' rnpcle to the scope of work withol.�i prior approval of Tukwila Bi ldin Division. OTE: Revisions will rcquiio ,a ri5- plan submittal and may inU(udf.) c.01ditian .l p!arl f`3vf ."iits.s . [2E01 riFIT:: FOR: LervICCharical IaQ �1CC:fiCc'?f Plumbing Ltd Gas Piping LE COPY Permit No, b11-- 00 99- Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel opy a7 9 ditions is acl�howled jod: By. Oa_ ).),(,(}-t ,', Date: �•,/ /-/-7 / /'7 'City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 4 2017 PERMIT CENTER LLJ Ly., 0 Ce u, - J I a �o N U M W o O)I-U • o= U ,0' c .0 = OC Q, N J co Q w V) •JLf)� a N > SEAL ROBERT STATE 0 DRAWINGS ISSUED DATE COMMENTS CCI r m CHECKED BY: FTW. U- 0 CD <- (-- 1 J � � m � n O CO 12 r--1 I REVIEVVED?Q )DE COMPLTAINIpq APPROVED APRR02017 City of -"IEwila BUILDING i (VISION 1 0 FI\ is SY V BOLS 0 S CH:D L FLOOR FINISHES CEILING FINISHES CT 2 WB 2 FLOOR IILL - "CROSSVILLE" SHADES AV248 THUNDER 12"x24" GROUT: BOSTIK SHADOW H195/ COBBLESTONE D-5441 1/16" GROUT LINE MAX. #425 ACRYLIC LATEX ADMIX-HYG 0042-505 #425 ACRYLIC LATEX ADMIX-HYG 0042-501 NOTE: T.G.C. TO ENSURE ACRYLIC LATEX ADMIX IS ADDED INTO GROUT MIX. [@ TOII FT ROOMS] WALL BASE - JOHNSONITE TRADITIONAL 08 ICICLE FIRE RATING: ASTM E648/NFPA 253 CLASS 1 ASTM E 84/NFPA 255 CLASS A/<450 [@ ALL AREAS ] ACT CEILING TILE: 'ARMSTRONG' DUNE SECOND LOOK II WITH j " GRID SCORED TEGULAR FINE TEXTURE COLOR: WHITE (11LE & GRID) DOOMS RAVES HADWA \OTES TILE DOOR NO. DOOR TYPE QTY. DOOR SIZE WIDTH HEIGHT TH K. MATL. FIN. FIRE RATING LABEL FRAME TYPE FRAME FINISH FRAME DETAIL HEAD JAMB FIRE RATING LABEL HINGES LOCK SET DOOR STOP DOOR CLOSER THRESHOLD/ WEATHER STRIPPING KICK PLATE NOTES/ REMARKS CPT 1 GENERAL CARPET TILE - INTERFACE UR103 COLOR: CUSTOM GREY COLOR #196 SIZE: 1m X 1m [@ SALES AND ALL CUSTOMER FACING AREAS] CPT 2 BROADLOOM CARPET - INTERFACE UR102 CUSTOM COLOR: 251559-209 [@ PLATFORMS WHERE INDICATED] CT 1 CERAMIC WALL TILE - US CERAMIC TILE U081 COLOR: WHITE ICE BRIGHT CT -1A - 3"x6" BULLNOSE CT -1 - 3"x6" SUBWAY WALL FIELD 11LE CT -18 - 3"x6" COVE BASE GROUT; BOSTIK WHITE H152/ WHITE D -G501 1/16" GROUT LINE MAX. #425 ACRYLIC LATEX ADMIX-HYG 0042-505 #425 ACRYLIC LATEX ADMIX-HYG 0042-501 NOTE: T.G.C. TO ENSURE ACRYLIC LATEX ADMIX IS ADDED INTO GROUT MIX. 6. 8 3'-0" 7'_6, DOOR OPENING. CHECK DOOR TYPE D EXIST. EXIST. PT -01 GLOSS CC301 WHITE EXIST. L-2 E 2 2'-6" 8'-0" 1" SC. WD. PT -2 DOOR AND DOOR FRAME PROVIDED BY FIXTURE MANUFACTURER DOOR HARDWARE PROVIDED BY FIXTURE MANUFACTURER DOOR AND DOOR HARDWARE TO BE PROVIDED BY FIXT. MANUFACTURER. T.G.C. TO PAINT DOOR PT -2 DOOR HARDWARE SPECIFICATIONS HINGES MAT 1 WALK -OFF MAT - THE MATWORKS CHAMPION WALK OFF MAT. TILE: 19.5" X 19.5"; i" THICK; COLOR: CHARCOAL; FLAMMABILITY: B55287:1989 [@ VESTIBULE] PAINT PT 1 WHITE - "SHERWIN WILLIAMS" EXTRA WHITE SW7006 GLOSS FINISH PROMAR [@ ALL DOORS AND DOOR TRIM U.O.N.] CT 3 BORDER TILE - AMERICAN OLEAN-LINEA "STORM GRAY" SIZE: 6" X .5" LINEAR TILE GROUT: BOSTIK WHITE H152/ WHITE D -G501 1/16" GROUT LINE MAX. #425 ACRYLIC LATEX ADMIX-HYG 0042-505 #425 ACRYLIC LATEX ADMIX-HYG 0042-501 NOTE: T.G.C. TO ENSURE ACRYLIC LATEX ADMIX IS ADDED INTO GROUT MIX. NO. ITEM DOOR QTY. MANUFACTURER NAME MODEL NO. SIZE FINISH NOTES LOCK SETS L-2 1 PR KWIKSET 155MIL 26D (MILAN) PUSH BUTTON SATIN CHROME FIN. EXISTING MIRRORED TRIM RING TEXTURES PT 2 SILVER - "SHERWIN WILLIAMS" MONORAIL SILVER FLAT FINISH [@ SALES AND ALL CUSTOMER FACING AREAS INCLUDING SLIDING DOORS AT CASHWRAP] PT 3 SILVER - "SHERWIN WILLIAMS" MONORAIL SILVER PRECAT SW7663 FINISH [@ DRESSING/FITTING ROOMS] PT 4 WHITE - "SHERWIN WILLIAMS" RHINESTONE SW7656 PROMAR 200 FLAT FINISH [@ BOH CORRIDOR, DOORS @CORRIDOR (INSIDE/OUTSIDE) AND T.R. WHERE LOCATED] PT 5 SILVER - "SHERWIN WILLIAMS" MORNING FOG SW6255 PROMAR200 FLAT FINISH [@ BACKWRAP LOGO WALL AND ADJACENT TRIM] PT 12 DARK GREY - "SHERWIN WILLIAMS" ROCK BOTTOM SW7062 PROMAR200 FLAT FINISH [@ VERA FEATURE WALL] TX 01 DRAPERY TEXTILE: CARNEGIE FABRICS: TREK PATTERN 4450/COL: 22 100% POLYESTER 118" WIDE/NFPA 701 PANEL SIZE: 87.5" H [CURTAINS @ SALES & B.O.H.] 00V EN S SCHEDULE N0. ROOM FLOOR BASE WALLS CEILING 001 VESTIBULE MAT -1 EXIST] EXIST EXIST 002 ENTRY CPT -1 WB -2 PT 2 EXIST 003 SALES AREA CPT -1] WB -2 PT PT PT 6 2 12 EXIST 004 DRESSING RM. AREA CPT-1ICPT-2 WB -2 PT PT 6 2 EXIST 005 CORRIDOR CPT -1 WB -2 PT 4 EXIST 006 MERCH. CLOSET CPT -1 WB -2 PT 2 EXIST 007 DRESSING ROOMS CPT -1 WB -2 PT PT CPT 1 3 2 EXIST 008 SHOE SHOP CPT -1 WB -2 PT PT 2 6 EXIST 009 ACCESSORY SHOP CPT -1 WB -2 PT PT 2 6 EXIST 010 SHOE CLOSET CPT -1 WB -2 PT 2 EXIST 011 OFFICE CPT -1 WB -1 EXIST EXIST 012 NOT USED 013 WOMEN'S TOILET RM. CT 2 CT 1B PT 4 EXIST 014 MEN'S TOILET RM. CT 2 CT 1B PT 4 EXIST 015 SHOE DYE EXIST EXIST EXIST EXIST 016 STAGING EXIST EXIST EXIST] EXIST 017 SEAMSTRESS STUDIO [CPT -1 WB -2 PT 2 EXIST 018 SEAMSTRESS FITTING ROOMS CPT -1 WB -2 PT 3 EXIST 019 ALTERATIONS EXIST ICPT-1 WB -2 EXIST EXIST 020 DRESSES CPT -1 WB -2 PT PT 2 6 EXIST 021 BRIDAL SELECTION CPT -1 WB -2 PT PT 2 6 EXIST 022 OFFICE / LOUNGE EXIST EXIST EXIST EXIST 023 CHECK-OUT AREA EXIST EXIST PT PT 2 5 EXIST DOOR TYPES DRESSING ROOM NUMBER INSTALLATION NOTES • T.O. HEADER 7'-31/2° L I TO I. OF CURTAIN ROD 11 f- r c Ol 1. REFER TO FIXTURE PLAN FOR SEQUENCE OF DRESSING ROOM NUMBERS. 2. T.G.C. TO LOCATE DRESSING ROOM NUMBERS AS INDICATED BELOW. i } 3. T.G.C. TO ATTACH/ADHERE TENANT PROVIDED NUMBERS PER MANUFACTURERS INSTRUCTIONS 4. CLEAN SURROUNDING MIRRORED AREAS AS REQUIRED. B.O. ACT CLG. EXIST. 27 28 4 9" DETAIL @ S3 261- 1'.-6 /2 SEE PLAN DETRAC< RFS2.0 SCALE : 1 1/2" = 1'-0" 29 SHOE CLOSET IOI I CPT -1 I CPT -1 (0 DRESSING ROOMS 007 I CPT -11 35 43 44 DRESSING ROOMS 007 CPT -1 35 DRESSING ROOMS 007 CPT -1 11-'1 P2 P2) X 3 O 4 E(D R 3> 39 -( P 2>- 0 vwvAA SHOE SHOP I 008 I 1 CPT -1 36 37 43 44 DRESS NG ROOM AREA IYP.3 I 004 ] I CPT -1 I 35 43 44 8 36 37 43 44 LI ALTERATIONS I 019 EXIST 0) SEAMSTRESS STUDIO I 017 �PT-ll a LI 0) 3 39 i 36 37 39 X B6.1 STAGING I 016 I EXIST CORRIDOR 005 I CPT -1 1 (0 (0 OFFICE OJ 011 36 43 37 44 4 m (P1 P2 DR3 r 0l 0 YP. 35 CPT -2 43 351 SEAMSTRESS FITTING RMS I 018 I ICPT-11 P2 1 CPT -1 SH OP I 009 1 CPT -11 i<> 35 36 37 43 44 43g / X X MERCH CLOSET 006 4 YP OFFICE[ LOUNG 022 [ EXIST I 36 37 43 44 35 35 DRESSING ROOMS 44 007 I CPT -1 I 42 46 36 37 43 44 42 / TYP.5 CHECK-OUT AREA I 023 I CPT -1] /SHOW SPIDIRTRACK WINDOW 36 37 fl 27 36 37 43 44 28 4 44 27 28 SPIDERTRACK SPIDERTRACK SPIDERTRA K 42 111 TYP.2 36 37 43 44 36 37 43 44 SPIDERTRACK ENTRY 002 I CPT -1 I 36 37 47 38 VESTIBULE 001 AI I L J 27 DRESSING ROOMS 007 I CPT -11 .35fr64 2 6 DRESSING ROOM AREA 1 004 43 37 44 TYP.7 1421 TYP.7 SELECTION 021 42 TYP.7 28 SPIDER TRACK (OR OR1 SHOW WINDOW CK 43 44 DRESSING ROOMS 007 35 43 44 DRESSING ROOMS 1 007 35 43 44 35 43 44 DRESSING ROOMS 007 7 ot 16 tt DOOR AND HARDWARE PROVIDED BY KRG AND INSTALLED BY T.G.C. KIT INCLUDES: • TRACK • CARRIERS • FLOOR GUIDES • RICHELIEW BRUSHED STAINLESS STEEL PULL 1-3/8" THICK MDF FLAT PANEL DOORS FASCIA PANEL TGC TO PAINT ALL SALES AND CUSTOMER FACING WALLS INCLUDING BUT NOT LIMITED TO, SALES AREA, SHOW WINDOWS, CORRIDORS, TOILET ROOMS AND HALLWAYS. DRESSING/FITTING ROOM HOOKS TO BE REMOVED AND REINSTALLED TO FACILITATE PROPER FINISHING. ALTERATIONS AND RECEIVING ROOMS ARE NOT TO BE PAINTED. REFER TO FINISH SCHEDULE FOR PAINT INFORMATION. /2. TGC TO INSTALL NEW CARPETING THROUGHOUT. SEE FINISH SCHEDULE AND PLAN 1/RFS2.0 FOR MORE INFORMATION. ?-77;3. TGC TO INSTALL NEW WALL BASE AT LOCATIONS OF NEW CARPET. SEE FINISH SCHEDULE FOR MORE INFORMATION. 4. TGC TO INSTALL NEW CORNER GUARDS, SANS BASE PLATES, AND REINSTALL EXISTING WALL BUMPERS AND ENDCAPS IN PLACE. 5. TGC TO INSTALL NEW DRESSING ROOM NUMBERS. SEE 1/RFS2.0 FOR NUMBER DESIGNATIONS AND DRESSING ROOM NUMBER DETAIL ON SHEET RFS2.0 FOR MORE INFORMATION. 6. TGC TO COORDINATE WITH ATLAS SIGN ON THE INSTALLATION OF THE NEW EXTERIOR SIGN. RE -CONNECT TO EXISTING ELECTRICAL OUTLET. 7. TGC TO COORDINATE WITH ATLAS SIGN ON THE INSTALLATION OF NEW MONUMENT SIGN. OTES 2 3 'EXISTING FLOORING TO REMAIN 1NEW VEIL FIXTURE PROVIDED BY DAVID'S BRIDAL. ID.B. TO INSTALL NEW CURTAINS 4 5 30 31 34 14 FINISHED FLOOR SCALE : 3" = L NOTE: T.G.C. TO PROVIDE & INSTALL GALV MENDING PLATES AT ALL JOINTS & CHECKOUT AREA CD 25 14 FINISHED FLOOR 34 " TO TOP OF HANGBAR NOTE: MENDING PLATES AT ALL JOINTS SECTION @ CHECKOUT AKA 32 21 20 wjEE / 10 FINISHED CEILING SEE SHEET A4.D FINISHED FLOOR TYPICAL 14 14 OSZ NEW NON -RATED RIOR PARTITION. 3 5/8" 20 GAUGE METAL STUDS AT 24" 0.C. TO UNDERSIDE OF CEILING OR SOFFIT. T.G.C. TO SECURE AT EVERY OTHER STUD TO EXISTING STRUCRJRE ABOVE. T.G.C. TO APPLY (1) LAYER 5/8" TYPE "X" GYPSUM BOARD TO EACH SIDE (OR 1 SIDE AS REQUIRED BY CONDITION AND LOCATION) TO 6" ABOVE CEILING TAPED & SPACKLED AND PREPARED AS REQUIRED FOR NEW FINISHES. (PROVIDE BLOCKING AS REQ'D. FOR MILLWORK & OTHER ITEMS AS DIRECTED BY CLIENT & MILLWORK CONTRACTOR. 3 '-10" 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 36 37 38 39 40 41 42 43 44 45 46 47 'EXISTING CURTAIN ROD, 0 AND U BRACKETS TO BE RE -USED. T.G.C. TO INSTALL NEW CURTAINS PROVIDED BY DAVID'S BRIDAL. 1T.G.C. TO INSTALL NEW CASHWRAP AND BACKWRAP PROVIDED BY FIXTURE MFR.. T.G.C. TO FOLLOW FIXT. MER'S INSTAL. MANUAL PROV. CASHWRAP FIXT. TO BE LOCATED 0.C. PER PLAN. INEW CASHWRAP CLOSET DOOR & HARDWARE TO BE PROVIDED BY FIXT. MANUFACTURER AND INSTALLED BY T.G.C. IT.G.C. TO INSTALL NEW DRESSING ROOM NUMBERS. SEE DRESSING RM. NUMBER INSTALLATION NOTES FOR MORE INFO. 1T.G.C. TO PROMDE 120V DUPLEX OUTLET MOUNTED AT 15" A.F.F. AND PRIVACY LOCKSET AT ADA DRESSING ROOM TO SERVE AS A LACTATION ROOM. T.G.0 TO PROVIDE WHITE DEVICE AND COVER PLATE. PRIVACY LOCK SET: (1) PAIR OF KWIKSET, MODEL 155ML 26D (MILAN) PUSH BUTTON PRIVACY IN SATIN CHROME FINISH AND TO INCLUDE ROSE PLATE TO MATCH. 1 in. TYPE 'X' GYPSUM BOARD BOTH SIDES TYP. (SEE SHEET RFS2.0 FOR FINISH SCHEDULE) 13r 20 GAUGE METAL STUDS @ 24" 0.0. 13i" X 20 GA. CONT. TRACK. ATTACH EACH WALLS TUD TO TRACK WTH (2) #10 SCREWS. ATTACH TRACK TO SLAB WITH (2) HILTI X -U INEW WALL BASE WB -2 INSTALLED BY T.G.C. SEE SHEET RES2.0 FOR MORE INFORMATION. IPROMDE J -BEAD TOP OF WALL ON BOTH SIDES. TAPE AND SPACKLE. 'FASCIA PANEL PROVIDED BY FIXT. MANUF. (KRG) AND INSTALLED BY T.G.C. T.G.C. TO PAINT PANEL TO MATCH ADJACENT FINISHES. COLOR TO MATCH ADJACENT WALL. SPEC TO BE METAL PAINT. REFER TO DETAIL 1/A5.0 FOR MORE INFORMATION 14" X 16 GA. CONTINUOUS TRACK ATTACH EACH WALL STUD TO TRACK WTH (2) #8 SCREWS. 116" SHELF BRACKET. IFILE CABINET INEW CREDENZA PROVIDED BY TENANT AND INSTALL BY T.G.C. 1NEW HOOKS INSTALLED BY TGC. INEW TRIM MOLDING APPLIED TO WALL TO BE PAINTED SIMILAR TO ADJACENT WALL. 1T.G.C. TO ENSURE THAT THERE IS "TWO NOTCHES" BETWEEN HANGBAR & SHELF @ STANDARDS. 114" HANG ROD BRACKET 8c HANG ROD. 116" X in PARTICLE BD. SHELF W/ WHITE MELAMINE FIN. SUPL. !EXISTING ACT CEILING TO REMAIN. 1NEW SURFACE MOUNTED SPIDER -MACK @ 9" APART 0.C.. SUPPLIED BY TENANT. SEE 4/RFS2.0 FOR MORE INFORMATION. T.G.C. TO ENSURE THAT SPIDER TRACKS WILL NOT CONFLICT W/ EXISTING LIGHT FIXTURES. T.G.C. TO COORDINATE EXACT LOCATION W/ DAVID'S BRIDAL. I T.G.C. TO FASTEN SPIDERTRACK THROUGH ALL PRE -DRILLED HOLES. REINFORCE CEILING/GRID AS REQ.D. [-EXISTING STOREFRONT SYSTEM 112" X in PARTICLE BD. SHELF WITH WHITE MELAMINE FIN. 112" SHELF BRACKET. ICASHWRAP DESK PROV. BY FIXTURE MFR. T.G.0 TO COORDIANTE LOCATION OF POWER & DATA AT NEW OW. INEW SIGN PROVIDED BY DAVID'S BRIDAL AND INSTALLED BY T.G.C. COORDINATE MOUNTING HEIGHT WITH DAVID'S BRIDAL. 172" WALL STANDARDS: INSTAL. W/ "HILTI" ANCHORS 24" 0.0. IT.G.C. TO REPLACE MISSING DRESSING ROOM HOOKS. IT.G.C. TO REPLACE ANY STAINED CEILING TILE 'RETROFIT 2X4 PRISMATIC LENS WITH 2X4 VOLUMETRIC AND REPLACE ALL WITH NON FLUORESCENT LIGHT FIXTURES AND ELECTRICAL Fra.C. TO COORDINATE REPLACE OF EXISTING SIGNAGE, TEMPORARY BANNER, & FACADE REPAIRS.WITH All_AS SIGN UNDER SEPARATE CONTRACT WITH DAVID'S BRIDAL. 'CURTAIN BY JADEN DRAPERY AND PANEL. SEE RES2.0 FOR MORE INFORMATION. NEW CURTAIN PROVIDED BY TENANT AND INSTALLED BY T.G.C. ADHERE CORNER GUARDS TO WALL WITH M1 STRUCTURAL ADHESIVE GLUE. APPROX 1 OZ GLUE PER CORNER GUARD. I NOT USED rRELOCATED FIXTURE IT.G.C. TO REPAIR WALLS, DOORS AND TRIM FOR PAINT. RETER TO FINISH SCHEDULE ON SHEET RES2.0 IT.G.C. TO REPAIR EXISTING DRYWALL CRACKS THROUGHOUT STORE AND PREPARE WALL SURFACES FOR LEVEL 5 FINISHES. INEW WELCOME DESK. T.G.C. TO COORDINATE NEW POWER/DATA AT THIS LOCATION. 'INDICATED WALLS TO BE PAINTED PT -12 "ROCK BOTTOM" FTGC TO INSTALL NEW WALK OFF MAT. SEE FINISH SCHEDULE FOR MORE INFORMATION. cc • N • 0 SEAL DRAWINGS ISSUED DATE COMMENTS CO CO CHECKED BY: FTW. NANT STORE NUMBER CO LO TOTAL SQ. FT.: 12,945 SQ. FT. PT AC <111RA ELEV. PT 2 ILA 00 CO PSCC AV -PROPOSED APPROVED L - City of TuIcOla BUILDING DIVISION DRAWING NO. PT PT PT avius BRI DAL 21 21 RECEIVE PPallfrIT 11-F NI 1 PT AC <111RA ELEV. PT 2 ILA 00 CO PSCC AV -PROPOSED APPROVED L - City of TuIcOla BUILDING DIVISION DRAWING NO. /KEY \OTES 1 2 (EXISTING DOOR TO REMAIN. T.G.C. TO PAINT DOOR AND FRAME PT -1. REFER TO FINISH SCHEDULE !TGC TO PROVIDE A SHARP TRANSITION PAINT LINE BETWEEN PT -3 AND PT -2. 3 1 RELOCATED HOOK TO BE MOUNTED @ 4'-0" A.F.F. 4 5 6 7 8 9 RELOCATED HOOK TO BE MOUNTED @ 6'-0" A.F.F. I EXISTING H.C. BENCH TO REMAIN 1T.G.C. TO PROVIDE 1"X5" BLOCKING FOR SUPPORT AT RELOCATED HOOKS. T.G.C. TO PAINT BLOCKING PT -3. (NEW WALL BASE. IT.G.C. TO PROVIDE 120V DUPLEX OUTLET MOUNTED AT 15" A.F.F. AND PRIVACY LOCKSET AT ADA DRESSING ROOM #18 TO SERVE AS A LACTATION ROOM. T.G.0 TO PROVIDE WHITE DEVICE AND COVER PLATE. PRIVACY LOCK SET: (1) PAIR OF KWIKSET, MODEL 155ML 26D (MILAN) PUSH BUTTON PRIVACY IN SATIN CHROME FINISH AND TO INCLUDE ROSE PLATE TO MATCH. !EXISTING STANDARD. 10 11 114" HANGBAR BRACKET IENDCAP FOR RECTANGULAR TUBING. 12 112'-0" RECTANGULAR BAR (TYP.) 13 (RECTANGULAR JOINTER 14 15 16 16' STANDARD (TYPICAL) 'WALL !FLOOR LINE. TYPICAL 3HSSI\G �OOv EXISTI \ G) \RFS3� SCALE : 1/2" = 1'-0" -0" 1,-6" 2'-0" 1'-6" 7'-0" H.C. D�ESSI\G OOIv (Ex!sTl\C; FS3� SCALE : 1/2" = 1'-0" �� 3�IDAL ISOIvERIC DTL \ RFS3. J SCALE : NOT TO SCALE V.I.F PT V.I.F PT 3 1 5 / / / / / ELEVATIO\ RFS3.0/ I If SCALE : 1/2" = 1'-0" 7 1 II PT 1 \ \ 4$ © 8'-0" V.I.F PT / j / L -V / / / / / / , J -u i -v — 3 3 / EQ. EQ. 6 4 // // / / 2 / / /U- / . 1B ELEVATIO\ RFS3.0// SCALE : 1/2" = 1'-0" l (2B�ELEVATIO QI L -V / 1 -u , J -u i -v — 6 3 / EQ. EQ. 4'-0" 1,2'-0" // // / / 2 / / /U- / ® D \ 30" X 48" 4 Q FORWARD 1--111\0 0 I! 1 5 APPROACH MINS 8 3 1 0 u IDN in S. .. 30" X 48" PARALLEL X11 1 3 '19 APPROACH SALES ASSOCIATE SIDE �4A \ CASH WRAP PLA\ RFS3.0% SCALE : 1/2" = 1'-0" I o I Mil T SALES ASSOCIATE SIDE 1'-2" 0 4B CASHWRAP RO\T ELEV. RFS3.0/ SCALE : 1/2" = 1'-0" (4ACCESSHLE CASH WRAP COU \ TES SCALE : 1/2" = 1'-0" SALES ASSOCIATE SIDE g \\ 0 / CUSTOMER FACING SIDE \ SCALE : 1/2" = 1'-0" 4'-0" 1' 30" X 48" FORWARD APPROACH 30" X 48" PARALLEL APPROACH 4'-0" WELCOME DES< PLA\ RFS3.0/ y SCALE : 1/2" = 1'-0" a 8'-O" V.I.F 4$ on R'-0" V.I.F PT 3 2 1C ELEVATIO\ RFS3.0 SCALE : 1/2" = 1'-0" / / / / / / / / / / // // PT — 6 3 / EQ. EQ. 1,2'-0" // // / / 2 / / /U- / D \ 4 5 ,12" MINS 8 3 1 0 u in S. .. (2C ELEVATIO\ FS3.0 SCALE : 1/2" = 1'-0" GENERAL NOTES 1. RECTANGULAR BAR TO BE CONNECTED BY A RECTANGULAR JOINTER AND SCREW TOGETHER FROM BACK OF BAR. 2. HILTI ANCHORS 1/4" TOGGLER BOLT TYP. TO BE USED FOR STANDARD INSTALLATIONS. USE (1) BOLT © EACH SECURING HOLE PER STANDARD 24" O.C. WHERE STANDARDS OCCUR AT METAL STUDS SECURE STANDARD TO STUD. 3. RECTANGULAR HANGBAR IS TO BE JOINED AT HANGBAR BRACKETS ONLY, NOT IN MID SPAN. OUTRIGGER SYSTEv OU T GGH SYSTEM SCALE : 1/4" = 1'-0" ASR' -n„ V.I.F / 2 PT EQ. 3 2'-O" EQ. �V.I.F ELEVAT0 SCALE : 1/2" = 1'-0" / / PT 3 4 / 1, O.F.C.I. BENCH FIXTURE. BENCH NOTE: FIXTURE TO BE FURNISHED BY DAVID'S BRIDAL, FIXTURE MANUF. AND INSTALLED BY GC. GC. TO INSTALL / MOUNT PER CODE. BRACING AS V-01 REQUIRED ///%%///////////////////// /////l/////////l/// ACCESS. El SCALE : 1-1/2" = 1'-0" \OOIV T.G.C. TO SECURE TO WALL WITH HILTI ANCHORS 6" METAL STRAPPING LL A\ 0� G DETAI LU ''' 0r; I- U c4 O I- 0 En J Q z = = J N J 00 Q 3 1-1-1 (� 0 • Ln a N N 0 O N LL SEAL ROBER STATE DRAWINGS ISSUED DATE COMMENTS OD JOB NUMBER:1713-17 CHECKED BY: FTW. TENANT STORE NUMBER: TOTAL SQ. FT.: 12,945 SQ. FT. FIXTURE SY V 3CLS SYMBOL ITEM SPECIFICATIONS QUANTITY SUPPL. BY (51) CHECKOUT - 2 POS SEE MILLWORK PACKAGE FOR MORE INFORMATION 1 FIXT. MANUF. CASH CLOSET STORAGE CREDENZA -MODULE C SEE MILLWORK PACKAGE FOR MORE INFORMATION 1 FIXT. MANUF. CHAIR ARMLESS, STACKING, WHITE WITH GREY UPHOLSTERY 32 TENANT (B6.) WEDDING PRESERVATION KITS SEE MILLWORK PACKAGE FOR MORE INFORMA11ON 2 FIXT. MANUF. PL. WEDDING SERVICES FIXTURE SEE MILLWORK PACKAGE FOR MORE INFORMA11ON 2 FIXT. MANUF. MEN'S WAREHOUSE FIXTURE SEE MILLWORK PACKAGE FOR MORE INFORMATION 1 FIXT. MANUF. SHOE BENCH SEE MILLWORK PACKAGE FOR MORE INFORMATION 1 FIXT. MANUF. (ORi 4'-0" OUTRIGGER SEE MILLWORK PACKAGE FOR MORE INFORMATION 15 FIXT. MANUF. (OR2> 3'-0" OUTRIGGER SEE MILLWORK PACKAGE FOR MORE INFORMATION 4 FIXT. MANUF. (P 1. ACCESSORY PANELS SEE MILLWORK PACKAGE FOR MORE INFORMATION 6 FIXT. MANUF. ACCESSORY PANELS SEE MILLWORK PACKAGE FOR MORE INFORMATION 9 FIXT. MANUF. CO J CO J EVE DE WM[ APR 0 4 ity of Tu BUI DING D CITY OF TUKWIL MAR 1 4 2017 PERMIT CENTEF (l) 0 LJLJf 1 n LTJ m F6' 'L.INC fE1 201, "cwi atm IV1SIO A w I - w w fl' NAVIGATION HANGERS X WELCOME DESK SEE MILLWORK PACKAGE FOR MORE INFORMATION 1 FIXT. MANUF. DRAWING NO. R -SJ 0 PT 4 11 PT 4 17 5 3/4" x -00 CLG HT @Aik EXIST. u 1 Cr) 0 x CV CC 0 CC CT 1B TOILET 00 v ELEVATIO\ SCALE : 1/2" = 1'-0" 11 ■ PT 5 3/4" 4 4 17 N 4 X CO CLG HT @dik EXIST. PT rE CT 1B TOILET ROOV ELEVATIO\ 4 K74.0% SCALE : 1/2" = 1'-0" CHANGING TABLE CHANGING TABLE 9'-2 1/2" E\LARGED TOILET ROOV PLA\ 0 SCALE 1/2" = 1'—O" 11 3" PT 3" 6 4 / 36" MIN. 131 4" MIN. j 2" MIN. 13 14 7 CT 1B ROO V ELEVATIO\ \FS4.0// SCALE : 1/2" = 1'-0" 11 // 1F \\ TOILET BOON ELEVATIO\ R S4,0% SCALE : 1/2" = 1'-0" GRAB BAR EXISTING PARTITION- 1 ARTITION 1 1_/2" 0 O.D. GRAB BAR 36" OR 42" LONG METAL BRACKETS: 4'-0" O.C. MAX WITH (3) 1/4"0 SELF DRILL / SELF TAPPING SCREWS THROUGH 3/16" THICK PLATE FOR GRAB OVER MIN (416 STUD1 CK WITHLATE #10 SCREWS © 3"O.C. EA STUD PAN PLATE OVER (4) STUDS METAL BLOCKING METAL STUD SEE FLOOR PLAN GRAS 3AR ATTACH V E\ T SCALE : NOT TO SCALE TYP. ORDER PATTR\ SCALE : NOT TO SCALE CLG HT @Atik EXIST. IV \ \ CLG HT ©Aiii EXIST. 1-1 CT -1 : WALL 3"x6" SUBWAY FIELD TILE GROUT JOINT SIZE: 1/16" PER MFR GROUT COLOR: SEE FINISH SCHEDULE CT -1: WALL 3"x6": FIELD CUT TO ASSURE TOP OF WALL TILE TO BE 33" A.F.F. BACK BUTTER ALL 3x6 TILES TO B FLUSH W/ FIELD TILE- TYP COVE BASE: CT -1B SIZE: 3" X 6" CERAMIC FLOOR TILE CT -2 12"x24" 11 PT 4 0" (39"-41 ") 13 12" MAX 13 2" MIN. N) r7 9 7 8 F CLG HT @ EXIST. CLC @ 40" (39"-41 ") 2" MIN. 13 —13 12" MAX r / 8 7 9 TOILET ROOM ELEVATIO\ \FS4.0 SCALE : 1/2" = 1'—D" B COVE SASE DETAIL RFS4.0 SCALE : NOT TO SCALE EX \ \ 11 PT \ \ 10 4 LOCATE PER. r MANUF. INSTRUCTIONS 1 U) r w 0- F - L_ L. TOILET .00N ELEVATIO\ SCALE : 1/2" = 1'-0" 11 CLG HT @adik EXIST. b 13 PT 36" MIN. 2" MIN. 24.. MIN. .4 t 13 4 3" 6 CLG HT @ EXIST. 111-1 7 14 CT 1B OTOILET �OOV ELEVATIO\ SCALE 1/2" = 1'-0" GENERAL NOTES NOTE: UPON CONSTRUCTION COMPLETION THE SEWER LINE IS TO BE VIDEODED FROM THE TOILET ROOM LOCATION TO THE SEWER MAIN CONTROLLED BY THE LANDLORD. THIS DIGITAL RECORDING IS TO BE PROVIDED TO DAVID'S BRIDAL CONSTRUCTION REPRESENTATIVE KEY NOTES 1 2 3 4 I EXISTING WATER CLOSET TO REMAIN. I EXISTING LAVATORY TO REMAIN. I NEW 18"X36" MIRROR SUPPLIED AND INSTALLED BY T.G.C. BOBRICK 8-165. I NEW LIGHT FIXTURE SUPPLIED BY TENANT AND INSTALLED BY T.G.C. GEORGE KOVACS LIGHTING 20.5"X4.75" UL RATED FOR DAMP LOCATION. P5044 -077-L: CHROME ETCHED OPAL SHADE PG5044 5 6 I EXISTING OUTLET TO REMAIN [WORLD DRYER MODEL #SUM/DR1 MODEL #L -974 -ADA AUTOMATIC 10 SECONDS DRY ALUMINUM WHITE COVER 120VOLT. HAND DRYER SUPPLIED BY DAVID'S BRIDAL AND INSTALLED BY T.G.C. INSTALL AFTER 11LE AS SHOWN. 7 I TOILET PAPER HOLDER PROVIDED BY DAVID'S BRIDAL INSTALLED BY T.G.C. 18 II TOILET SEAT COVER HOLDER SUPPLIED BY DAVID'S BRIDAL INSTALLED BY T.G.C. 9 10 11 12 13 14 15 16 17 18 I SANITARY NAPKIN DISPOSAL SUPPLIED BY DAVID'S BRIDAL AND INSTALLED BY T.G.C. I DIAPER -DEPOT HORIZONTAL BABY CHANGING STATION. HORIZONTAL BABY CHANGING TABLE SUPPLIED BY DAVID'S BRIDAL INSTALLED BY T.G.C. INSTALL & ANCHORING PER MANUF. INSTRUCTIONS. I EXISTING GYP. BD. CEILING TO REMAIN. REPLACE ANY DAMAGED TILES. 'GLASS TILE: GARDEN STATE TILE, "STORM GRAY" CT -3. SEE FINISH SCHEDULE ON SHEET A2.01 FOR MORE INFORMATION. I T.G.C. TO PROVIDE NEW GRAB BAR I NEW TRU-BRO "LAV-GUARD2" UNDERSINK PIPE COVERS TO COMPLY WITH ADA REQUIREMENTS I SURFACE MOUNTED TOWEL PIN-BOBRICK 8-677/8-6777 SUPPLIED AND INSTALLED BY T.G.C. I COAT HOOK MOUNTED AT 4'-0" A.F.F. PROVIDED BY DB INSTALLED BY T.G.C. I LIGHT SENSOR. SOAP DISPENSER SUPPLIED BY DAVID'S BRIDAL BOBRICK LIQUIDMATE LIQUID SOAP DISPENSER B-155 mJZ TWO a, - H U • 0I _rn ¢,-1< ,U' a, N �coQ w d N 0 • J 111 = a N SEAL 9314 RE ISTERED A1 tHlrEcT i ROB /.ARGENTI STAT SHINGTON r rA DRAWINGS ISSUED DATE COMMENTS REVIEWED FOR CODE COMPLIANC APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISIO JOB NUMBER:1713-17 CO CO CHECKED BY: FTW. TENANT STORE NUMBER: 12,945 SQ. FT. r pig oast J CIL m R CITY PERM CI) LTJ n Cr) :CEIVEEL )F TUKWILA w !! 1 4 26ii IT CENTER DRAWING NO. HHS4O ..-- --•PT 4 4 A LOCATE PER. MANUF. INSTRUCTIONS / \ U) 0 ro r C s U O 15- Z a \ t J // 1F \\ TOILET BOON ELEVATIO\ R S4,0% SCALE : 1/2" = 1'-0" GRAB BAR EXISTING PARTITION- 1 ARTITION 1 1_/2" 0 O.D. GRAB BAR 36" OR 42" LONG METAL BRACKETS: 4'-0" O.C. MAX WITH (3) 1/4"0 SELF DRILL / SELF TAPPING SCREWS THROUGH 3/16" THICK PLATE FOR GRAB OVER MIN (416 STUD1 CK WITHLATE #10 SCREWS © 3"O.C. EA STUD PAN PLATE OVER (4) STUDS METAL BLOCKING METAL STUD SEE FLOOR PLAN GRAS 3AR ATTACH V E\ T SCALE : NOT TO SCALE TYP. ORDER PATTR\ SCALE : NOT TO SCALE CLG HT @Atik EXIST. IV \ \ CLG HT ©Aiii EXIST. 1-1 CT -1 : WALL 3"x6" SUBWAY FIELD TILE GROUT JOINT SIZE: 1/16" PER MFR GROUT COLOR: SEE FINISH SCHEDULE CT -1: WALL 3"x6": FIELD CUT TO ASSURE TOP OF WALL TILE TO BE 33" A.F.F. BACK BUTTER ALL 3x6 TILES TO B FLUSH W/ FIELD TILE- TYP COVE BASE: CT -1B SIZE: 3" X 6" CERAMIC FLOOR TILE CT -2 12"x24" 11 PT 4 0" (39"-41 ") 13 12" MAX 13 2" MIN. N) r7 9 7 8 F CLG HT @ EXIST. CLC @ 40" (39"-41 ") 2" MIN. 13 —13 12" MAX r / 8 7 9 TOILET ROOM ELEVATIO\ \FS4.0 SCALE : 1/2" = 1'—D" B COVE SASE DETAIL RFS4.0 SCALE : NOT TO SCALE EX \ \ 11 PT \ \ 10 4 LOCATE PER. r MANUF. INSTRUCTIONS 1 U) r w 0- F - L_ L. TOILET .00N ELEVATIO\ SCALE : 1/2" = 1'-0" 11 CLG HT @adik EXIST. b 13 PT 36" MIN. 2" MIN. 24.. MIN. .4 t 13 4 3" 6 CLG HT @ EXIST. 111-1 7 14 CT 1B OTOILET �OOV ELEVATIO\ SCALE 1/2" = 1'-0" GENERAL NOTES NOTE: UPON CONSTRUCTION COMPLETION THE SEWER LINE IS TO BE VIDEODED FROM THE TOILET ROOM LOCATION TO THE SEWER MAIN CONTROLLED BY THE LANDLORD. THIS DIGITAL RECORDING IS TO BE PROVIDED TO DAVID'S BRIDAL CONSTRUCTION REPRESENTATIVE KEY NOTES 1 2 3 4 I EXISTING WATER CLOSET TO REMAIN. I EXISTING LAVATORY TO REMAIN. I NEW 18"X36" MIRROR SUPPLIED AND INSTALLED BY T.G.C. BOBRICK 8-165. I NEW LIGHT FIXTURE SUPPLIED BY TENANT AND INSTALLED BY T.G.C. GEORGE KOVACS LIGHTING 20.5"X4.75" UL RATED FOR DAMP LOCATION. P5044 -077-L: CHROME ETCHED OPAL SHADE PG5044 5 6 I EXISTING OUTLET TO REMAIN [WORLD DRYER MODEL #SUM/DR1 MODEL #L -974 -ADA AUTOMATIC 10 SECONDS DRY ALUMINUM WHITE COVER 120VOLT. HAND DRYER SUPPLIED BY DAVID'S BRIDAL AND INSTALLED BY T.G.C. INSTALL AFTER 11LE AS SHOWN. 7 I TOILET PAPER HOLDER PROVIDED BY DAVID'S BRIDAL INSTALLED BY T.G.C. 18 II TOILET SEAT COVER HOLDER SUPPLIED BY DAVID'S BRIDAL INSTALLED BY T.G.C. 9 10 11 12 13 14 15 16 17 18 I SANITARY NAPKIN DISPOSAL SUPPLIED BY DAVID'S BRIDAL AND INSTALLED BY T.G.C. I DIAPER -DEPOT HORIZONTAL BABY CHANGING STATION. HORIZONTAL BABY CHANGING TABLE SUPPLIED BY DAVID'S BRIDAL INSTALLED BY T.G.C. INSTALL & ANCHORING PER MANUF. INSTRUCTIONS. I EXISTING GYP. BD. CEILING TO REMAIN. REPLACE ANY DAMAGED TILES. 'GLASS TILE: GARDEN STATE TILE, "STORM GRAY" CT -3. SEE FINISH SCHEDULE ON SHEET A2.01 FOR MORE INFORMATION. I T.G.C. TO PROVIDE NEW GRAB BAR I NEW TRU-BRO "LAV-GUARD2" UNDERSINK PIPE COVERS TO COMPLY WITH ADA REQUIREMENTS I SURFACE MOUNTED TOWEL PIN-BOBRICK 8-677/8-6777 SUPPLIED AND INSTALLED BY T.G.C. I COAT HOOK MOUNTED AT 4'-0" A.F.F. PROVIDED BY DB INSTALLED BY T.G.C. I LIGHT SENSOR. SOAP DISPENSER SUPPLIED BY DAVID'S BRIDAL BOBRICK LIQUIDMATE LIQUID SOAP DISPENSER B-155 mJZ TWO a, - H U • 0I _rn ¢,-1< ,U' a, N �coQ w d N 0 • J 111 = a N SEAL 9314 RE ISTERED A1 tHlrEcT i ROB /.ARGENTI STAT SHINGTON r rA DRAWINGS ISSUED DATE COMMENTS REVIEWED FOR CODE COMPLIANC APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISIO JOB NUMBER:1713-17 CO CO CHECKED BY: FTW. TENANT STORE NUMBER: 12,945 SQ. FT. r pig oast J CIL m R CITY PERM CI) LTJ n Cr) :CEIVEEL )F TUKWILA w !! 1 4 26ii IT CENTER DRAWING NO. HHS4O KEYED NOTES 0 U.N.O. ALL EXISTING LIGHTING, POWER, AND MECHANICAL SYSTEMS ARE TO REMAIN AS -IS. RE -USE EXISTING POWER AND DATA FROM EXISTING PODIUM. SAWGUT TO NEW PODIUM LOCATION ®PROVIDE NEW POWER AND DATA REGEPTAGLES IN NEW GASHWRAP MILLWORK. RE -USE EXISTING POWER CIRCUITS AND DATA LABELING. REPAIR/ REPLACE AS NEED TO PROVIDE A FULLY WORKING SYSTEM. NEW DATA COMMUNICATIONS AND POWER DEVICES ARE TO BE MOUNTED INSIDE CABINET. G.G. TO PROVIDE 2X4 HANDBOX HUBBEL-RAGO: #66 (4) TRENCH IN SLAB AS REQUIRED FOR ELECTRICAL AND DATA CONDUITS. PROVIDE (2) 3/4" CONDUITS. (I) TO BE DEDICATED TO POWER, (I) FOR DATA COMMUNICATIONS. BOTH CONDUITS TO HAVE PULLSTRINGS CLEARLY MARKED FOR DESIGNATED USE. EXISTING PODIUM TO BE REMOVED. SEE ARCHITECTURAL PLANS FOR FULL SCOPE. EXISTING POWER CIRCUITS AND DATA LINES TO REMAIN. PROTECT DURING DEMOLITION FOR RE -USE. EXISTING GASHWRAP DESK TO BE REMOVED. SEE ARCHITECTURAL PLANS FOR FULL SCOPE. EXISTING POWER CIRCUITS AND DATA LINES TO REMAIN. PROTECT DURING DEMOLITION FOR RE -USE. CONNECT TO EXISTING GIRGUIT A5 SHOWN CONNECT TO OPEN SPARE WITH CAPACITY ON EXISTING PANEL 'LP'. THIS IS TO BE A DEDICATED GIRGUIT AND NOT TO BE SHARED WITH ANY OTHER RECEPTACLES CONNECT TO OPEN SPARE WITH CAPACITY ON EXISTING PANEL 'LP'. 4111111 0111110•__ 00001___-__--_ x -X rc� ID ... x "Pk 0 k DI DI Dl -32 L1 1- r F. L1 L IT 0 Li 0 I, V(1) @18" V O@18" � A.F.F. r� Tdil -70 -E0 a) @18" A.F.F. x 0 I I I 0 �q> x POV1ER FLOOR PLAN SGALE : VS" = I' -O" IF -11 ite- Q U 5 k5 C, 100?) L [T YS 2.1 I REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISION DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 0 817.410.28581 F 817.251.8411 SEAL DRAWINGS ISSUED DATE COMMENTS SPACE NUMBER: JOB NUMBER: TENANT STORE NUMBER: TOTAL 50. FT.: cv) J 0 ce m F CITY PER( >_ 1 Y II I ECEI JED OF T U KW I I_ AR 1 42017 JT CENTER DRAWING NO. -I- I �q> x POV1ER FLOOR PLAN SGALE : VS" = I' -O" IF -11 ite- Q U 5 k5 C, 100?) L [T YS 2.1 I REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISION DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 0 817.410.28581 F 817.251.8411 SEAL DRAWINGS ISSUED DATE COMMENTS SPACE NUMBER: JOB NUMBER: TENANT STORE NUMBER: TOTAL 50. FT.: cv) J 0 ce m F CITY PER( >_ 1 Y II I ECEI JED OF T U KW I I_ AR 1 42017 JT CENTER DRAWING NO.