HomeMy WebLinkAboutPermit D17-0090 - RED DOT - SEISMIC UPGRADERED DOT 745 ANDOVER PARK E D17-0090 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049115 Permit Number: D17-0090 745 ANDOVER PARK E Project Name: RED DOT Issue Date: 5/17/2017 Permit Expires On: 11/13/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LBA NCC -COMPANY III LLC PO BOX 847 , CARLSBAD, WA, 92018 KIM OSPINA 600 UNIVERSITY ST, STE 3025 , SEATTLE, WA, 98101 'SAUNDERS CONSTRUCTION INC 1760 MONROVIA AVE UNIT A-1, COSTA MESA, CA, 92627 SAUNDCI953ND LBD NCC - COMPANY III, LLC 3347 MICHAELSON DR, STE 220, IRVINE, WA, 92612 Phone: (206) 812-6232 Phone: (949) 646-0034 Expiration Date: 8/4/2017 DESCRIPTION OF WORK: VOLUNTARY SEISMIC STRENGTHENING OF THE WALL ANCHORAGE SYSTEMS TO REDUCE THE POTENTIAL STRUCTURAL DAMAGE IN AN EARTHQUAKE Project Valuation: $200,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $4,099.51 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm' Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: 5.t'si•-• 17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to t conditions attached to this permit. Signatur Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3 All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 5: When special inspection is required, either the owner or the registered design professional in responsible harge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. 0 o 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0401 ROOF SHEATHING 4046 SI-EPDXY/EXP CONC 4034 SI -METAL PLATE CONN 4023 SI -OBS -SEISMIC REST CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov n Building Permit No. ►/'q"'CM0 Project No. Date Application Accepted: Date Application Expires: 10 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2623049115 Site Address: 745 Andover Park East Tenant Name: Red Dot Suite Number: NA Floor: NA PROPERTY OWNER Name: LBA NCC -Company III, LLC Address: 3347 Michaelson Drive, Suite 220 City: Irvine State: WA Zip: 92612 CONTACT PERSON — person receiving all project communication Name: Kim Ospina Company Name: MHP, Inc. Address: 600 University Street, Suite 3025 City: Seattle State: WA Zip: 98101 Phone: (206) 812-6232 Fax: (206) 812-2700 Email: kospina@lbarealty.com - City: GENERAL CONTRACTOR INFORMATION Company Name: Company Name: MHP, Inc. Company Name: NA Engineer Name: Kenneth D. O'Dell Address: Architect Name: City: Long Beach State: CA City: State: 985-1011 Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line 2011 Applications''crmit Application Revised - 8-9-1I.docx Revised: August 2011 bh New Tenant: ❑ Yes J .. No ARCHITECT OF RECORD Name: LBA NCC -Company III, LLC Company Name: MHP, Inc. Company Name: NA Engineer Name: Kenneth D. O'Dell Architect Name: City: Long Beach State: CA Address: Phone: (562) 985-3200 Fax: (562) 985-1011 City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: LBA NCC -Company III, LLC Company Name: MHP, Inc. City: Irvine State: WA Zip: 92612 Engineer Name: Kenneth D. O'Dell Address: 3900 Cover Street City: Long Beach State: CA Zip: 90808 Phone: (562) 985-3200 Fax: (562) 985-1011 Email: kodell@mhpse.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: LBA NCC -Company III, LLC Address: 3347 Michaelson Drive, Suite 220 City: Irvine State: WA Zip: 92612 Pagel of 4 BUILDING PERMIT INFORMATION 206-431-3670 Valuation of Project (contractor's bid price): $ 200,000 Describe the scope of work (please provide detailed information): The project is a voluntary seismic strengthening of the wall anchorage systems to reduce the potential structural damage in an earthquake. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 207,346 Floor area of principal dwelling: 103,218 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. 0 Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes 81 Compact: Handicap: L No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Z Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-12" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15t Floor 103,484 2"d Floor 10,518 3`d Floor 0 Floors thru Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 207,346 Floor area of principal dwelling: 103,218 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. 0 Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes 81 Compact: Handicap: L No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Z Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-12" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑ ... V alley View 0 .. Renton 0... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut 0 ...Total Fill cubic yards cubic yards 0 .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 ...Cap or Remove Utilities 0 .. Curb Cut ❑ ...Frontage Improvements 0 .. Pavement Cut 0 ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention - Fire Protection " Irrigation Domestic Water " ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # 0 ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size 0 ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications'Forrns-Applications On Line\2011 Applications\Permit Application Revised - 8-9.1 Ldocx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: 1 R AUTHOJUZED AGENT: Print Name: (1 1 Ar OJPl/L Mailing Address: C$O V/Yk Date: at v ` / 2i /t Z-0‘0 f�/ 2 Day Telephone: Z -n �tY- 3oz, kiettip qrl % City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Pcnnit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number R11508 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK .: PAID $2,533.77 D17-0090 Address: 745 ANDOVER PARK E Apn: 2623049115 $2,533.77 DEVELOPMENT $2,413.33 PERMIT FEE R000.322.100.00.00 0.00 $2A08.83 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $120.44 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R11508 x $120.44 $2,533.77 Date Paid: Wednesday, May 17, 2017 Paid By: LBA NCC -COMPANY III LLC Pay Method: CHECK 000132 Printed: Wednesday, May 17, 2017 3:28 PM 1 of 1 ! SYSTEMS 111 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $1,565.74 D17-0090 Address: 745 ANDOVER PARK E Apn: 2623049115 $1,565.74 DEVELOPMENT $1,565.74 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11266 R000.345.830.00.00 0.00 $1,565.74 $1,565.74 Date Paid: Thursday, April 13, 2017 Paid By: LBA NCC -COMPANY III LLC Pay Method: CHECK 000116 Printed: Thursday, April 13, 2017 2:32 PM 1 of 1 CRSYSTEMS INSPECTION N0. INSPECTION RECORD Retain a copy with permit b7-00,90 PERMIT NO. CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670`` Permit Inspection Request Line (206) 438-9350 Project: t ba " Tye of Inspection: e I 1 tbiW6- linfA 1 - Address: 745/Attu eArJc C Date Called: Special Instructions: £Au. 20 r�1S Al- b Date Wage • b Z l a_m. Request : gl IW Phone No: c03- 7o6, -O62-6 igtApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspector: 4 Dates 011 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. RECEIVED CITY OF TUKWILA APR ;111017 PERMIT CENTER STRUCTURAL CALCULATIONS for VOLUNTARY SEISMIC STRENGTHENING 745 Andover Park East Tukwila, Washington 98188 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 4 2017 Oil of T ikwiIa BtlI for LBA Realty 600 University Street, Suite 3025 Seattle, WA 98101 by MHP, Inc. Structural Engineers Long Beach, California March 13, 2017 MHP JN: 17-0008-01 DI 1/0ogo STRUCTURAL ENGINEERS Design Maps Summary Report Page 1 of 1 1 L§USGS Design Maps Summary Report User -Specified Input Building Code Reference Document ASCE 41-13 Retrofit Standard, BSE -1E (,IKe 9 (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44927°N, 122.25184°W Site Soil Classification Site Class D - "Stiff Soil" `Sr r1*' y� • Z � .1 ss quah en ton _`... Kent USGS-Provided Output 55,20/50 0.489 g SXS,BSE-1E 0.689 g 51,20/50 0.179 g SX1,BSE-1E 0.372 g Horizontal Spectrum 0,70 0.63 0.5E 0,49 0,42 0.35 0:28 0.21 0.14 0.0 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 2.00 Period. T (sec) • t F =.:. t art :l iH obi Maple Valley C 9rC e t Covington ,1 0.55 0.50 0,45 0.40 0.15 0,30 0.25 0.20 0.15 00.10 0-05' 0.00 0.00 0.20 0.40 0.60 Vertical Spectrum 0.'80 L00 1.20 1_.40 Period. T (sec) 1.60 1.80 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. http://earthquake.usgs. gov/designmaps/us/summary.php?template=minimal&latitude=47.4... 1 /12/201 7 1/25/2017 Design Maps Summary Report MUMS Design Maps Summary Report 2 User -Specified Input jjD;�1 Building Code Reference Document ASCE 41-13 Retrofit Standard, BSE -2E (CBIst+A1'S P (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44927°N, 122.25184°W Site Soil Classification Site Class D -"Stiff Soil" USGS-Provided Output Ss,s/50 1.008 g S1,5/50 0.385 g 1.20 1.09 0.95 0.94 th 0.7 0.50 0.49 0.35 0.24 0.12 SXS,BSE-2E 1.105 g SX1,BSE-2E 0.628 g Horizontal Spectrum 0.89 0.80 0.72 0.64 0.56 G 0.49 to • 0.40 0.32 0.24 0.16 0.08 0.00 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 Period. T (sec) Vertical Spectrum 1.60 1.80 2.00 0.00 0.20 0.40 0.50 0.90 1.00 1.20 1.40 1.60 1.90 Period. T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. http://earthquake. us gs .gov/des i gn m aps/us/s um m ary. ph p?tem pl ate=minimal &latitude= 47.44927&I ongi tude=-122.251838&s i tecl ass= 3&risk category= -1 &edition=... 1/1 CALCULATION SHEET STRUCTURAL ENGINEERS 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 56/985.1011 F www.mhpse.com CALCULATION SHEET -(1,..A DATE: JOB NO: 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.101 I F www.mhpse.com MILT. www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-3200 1562-985-1011 Page: 1 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 Specifier's comments: Si (J ciu 11)-7)-141—, 1 Input data Anchor type and diameter: HIT -RE 500 V3 + HAS 5/8 Effective embedment depth: hef,act = 4.500 in. (henimit = - in.) Material: 5.8 Evaluation Service Report: ESR -3814 Issued I Valid: 6/1/2016 1 1/1/2017 Proof: Design method ACI 318-14 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plate: Ix x ly x t = 4.000 in. x 10.000 in. x 0.500 in.; (Recommended plate thickness: not calculated Profile: no profile Base material: cracked concrete, 2500, fc' = 2500 psi; h = 6.000 in., Temp. short/long: 32/32 °F Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [Ib, in.Ib] z Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-32001 562-985-1011 Page: 2 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1536 0 0 0 2 1536 0 0 0 max. concrete compressive strain: - [%o] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 3072 [Ib] resulting compression force in (x/y)=(0.000/0.000): 0 [Ib] 3 Tension Toad Load Nun [Ib] Capacity 4, N„ [Ib] Utilization fiN = Nua/4) Na Status Steel Strength* 1536 10650 15 OK Bond Strength** 3072 9493 33 OK Sustained Tension Load Bond Strength* N/A N/A N/A N/A Concrete Breakout Strength** • 3072 7423 42 OK * anchor having the highest loading **anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value refer to ICC -ES ESR -3814 0 Nsa 2 Nua ACI 318-14 Table 17.3.1.1 Variables Ase,N [I12] fut. [psi] 0.23 Calculations Nsa [Ib] 16385 Results Nsa [Ib] 16385 72500 steel.. Nsa [Ib] =11 10650 Nua [Ib] 1536 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan M111161711 www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-3200]562-985-1011 Page: 3 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 3.2 Bond Strength Nag = (ANa AN.0) 1V ecl,Na 1V ec2,Na W ed,Na W cp,Na Nba Nag > Nua ANa = see ACI 318-14, Section 17.4.5.1, Fig. R 17.4.5.1(b) ANaO = (2 0Na)2 CNa = 1 O da Alt un"V1100 1 W ec.Na = (ii) 5 1.0 CNa l W ed,Na = 0.7 + 0.3 ( Gran/ 5 1.0 W cp,Na = MAX(Camin CNa) c 1.0 Cac Cac Nba = A. a ' t k.c ' 1[ ' da ' her Variables t k,c,uncr [psi] 2210 e. -1,N [in.] da [in.] 0.625 ec2,N [in.] her [in.] ACI 318-14 Eq. (17.4.5.1.b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.5.1c) ACI 318-14 Eq. (17.4.5.1d) ACI 318-14 Eq. (17.4.5.3) ACI 318-14 Eq. (17.4.5.4b) ACI 318-14 Eq. (17.4.5.5b) ACI 318-14 Eq. (17.4.5.2) ca,min [in.] 4.500 Cac [in.] 0.000 Calculations CNa [in.] 8.819 W ec1,Na 1.000 Results 0.000 ANa [in.2] 10.194 ANaO [in.2] 408.10 311.09 W ec2,Na 1.000 Nag [Ib] and 14605 3.3 Concrete Breakout Strength W cp,Na 1.000 1.000 1� cd,No 1.000 Nba [Ib] 11133 4) Nag [Ib] Nue [Ib] 9493 3072 Ncbg = (ANc ANco) W ec,N W ed,N W c,N W cp,N Nb Ncbg ? Noe ANe see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANcO W ec,N W ed,N W cp,N Nb =9hf 1 1+2eN 551.0 3 her = 0.7 + 0.3 (1.5Came) s 1.0 et = MAX("',a,i1.5har) 5 1.0 `` Cac Cac 1 =keA,aYTchei5 Variables hef [in.] ec1,N [In.] 4.500 0.000 ec2,N [in.] 0.000 t k.c [psi] 1260 ACI 318-14 Eq. (17.4.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.2.1c) ACI 318-14 Eq. (17.4.2.4) ACI 318-14 Eq. (17.4.2.5b) ACI 318-14 Eq. (17.4.2.7b) ACI 318-14 Eq. (17.4.2.2a) cam*, [in.] W c,N cac [in.] kc 7,. a fc [psi] 10.194 17 1.000 .2500 1.000 Calculationsl� ^Nc [in.2] ANcO [in•2] W ec1,N W ec2,N 1V ed,N W cp,N Nb [Ib] 256.50 182.25 1.000 1.000 1.000 1.000 8114 Results Ncbg [Ib] 11420 oncrete 0 0 Ncbg [Ib] Nua [Ib] 7423 3072 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hill AG, FL -9494 Schaan Hill is a registered Trademark of Hilti AG, Schaan SUBJECT: STRUCTURAL ENGINEERS oLuyv'i-k(l s Wuz- CALCULATION��SHEET JOB NO: /� /0bo DATE: BY: SHEET: 8 3900 Cover Street, Long Beach, CA 90808-1773 562.9853200 P 562.985.1011 F www.mhpse.com I■111`TI www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-3200 I 562-985-1011 Page: 1 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 Specifier's comments: U44144, )ioeir i 1 Input data Anchor type and diameter: HIT -RE 500 V3 + HAS 5/8 Effective embedment depth: hef,aa = 4.500 in. (het,limit = - in.) Material: 5.8 Evaluation Service Report: ESR -3814 Issued I Valid: 6/1/2016 1 1/1/2017 Proof: Design method ACI 318-14 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plate: Ix x ly x t = 4.000 in. x 10.000 in. x 0.500 in.; (Recommended plate thickness: not calculated Profile: no profile Base material: cracked concrete, 2500, fc' = 2500 psi; h = 6.000 in., Temp. short/long: 32/32 °F Installation: , hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [Ib, in.ib] z Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1111411191 www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-32001562-985-1011 Page: 2 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 2 Load case/Resulting anchor forces Load case: Design Ioads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 2048 0 0 0 2 2048 0 0 0 max. concrete compressive strain: - [%o] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 4096 [Ib] resulting compression force in (x/y)=(0.000/0.000): 0 [Ib] 3 Tension Toad Load Nua [Ib] Capacity 4) Nn [Ib] Utilization RN = Nua/ N„ Steel Strength* 2048 10650 Bond Strength** 4096 9698 Sustained Tension Load Bond Strength* N/A N/A Concrete Breakout Strength** 4096 7618 * anchor having the highest loading **anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value Nsa Z N. Variables f 1 Ase,N [In•2] refer to ICC -ES ESR -3814 ACI 318-14 Table 17.3.1.1 futa [psi] 0.23 Calculations Nsa [Ib] 16385 Results Nsa [Ib] 16385 72500 Nsa [Ib] N. [Ib] 10650 2048 20 43 N/A 54 Status OK OK N/A OK Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan G0 www.hilti.us Profis Anchor 2.7.1 Company: Specifier: Address: Phone I Fax: E -Mail: MHP 3900 Cover Street, Long Beach, CA 562-985-3200 1 562-985-1011 Page: 3 Project: Voluntary Retrofit Sub -Project I Pos. No.: 745 Andover Park East Date: 1/20/2017 3.2 Bond Strength ( ANa Nag — ANa0/ tV ec1,Na W ec2,Na W ed,Na W cp,Na Nba Nag > Nua ANa = see ACI 318-14, Section 17.4.5.1, Fig. R 17.4.5.1(b) A A Na0 = (2 Clda)2 CNa = 10 da 1100t uncr 1 Wec,Na— \1+eN1s1.0 CNa / Wed.Na=0.7+0.3 (Ca ") <_ 1.0 / CNa 1 W cp,Na = MAX (Ca min CNa) c 1.0 Cac Cac Nha = k a ' t k,c-"n - da . hef Variables t k,c,uncr [psi] de [in.] het [In.] 2210 0.625 4.500 ea -1,N [in.] ea2,N [in.] ca. [in.] ACI 318-14 Eq. (17.4.5.1.b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.5.1c) ACI 318-14 Eq. (17.4.5.1d) ACI 318-14 Eq. (17.4.5.3) ACI 318-14 Eq. (17.4.5.4b) ACI 318-14 Eq. (17.4.5.5b) ACI 318-14 Eq. (17.4.5.2) Ca,min [in.] 0.000 0.000 10.194 Calculations CNa [in.] ANa [In.2] ANaO [in.2] 8.819 416.92 311.09 W ec1,Na W ec2,Na W cp,Na 1.000 1.000 1.000 . Results Nag [lb]�on 4) Nag [lb] 14920 0" ' 9698 3.3 Concrete Breakout Strength b 1.000 W ed.Na 1.000 Nba [Ib] 11133 Nua [Ib] Ncbg _ (ANc ANc!) W ec,N W ed,N W c,N W cp,N Nb Ncbg Z Nua ANe see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANc0 W ec,N W ed,N W cp,N Nb = 9 het 1 _ \ (+2eN 551.0 3 het = 0.7 + 0.3 (1 5hef) 5 1.0 = MAX(!,Camin 1.5hef) 5 1.0 Cac Cac f =kcX.a 4Tchei5 Variables hef [in.] ea -1,N [in.] ec2,N [in.] 4.500 0.000 0.000 4096 T k,c [psi] 1260 ACI 318-14 Eq. (17.4.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.2.1c) ACI 318-14 Eq. (17.4.2.4) ACI 318-14 Eq. (17.4.2.5b) ACI 318-14 Eq. (17.4.2.7b) ACI 318-14 Eq. (17.4:2.2a) ca,a [in.] W c,N ^� 1.000 Cac [in.] kc A. a fc [psi] 10.194 17 1.000 2500 Calculations AN, [in.2] ANco [in.2] 1l1 eci,N W ec2,N 263.25 182.25 1.000 1.000 Results A,k Nebg [Ib] 4). oncrete 4) Ncbg [lb] Nua [Ib] W ed,N 11720 7618 4096 9,4 o 1.000 W cp,N Nb [Ib] 1.000 8114 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan IN( STRUCTURAL ENGINEERS SUBJECT: DATE: CALCULATION SHEET JOB NO: j /°0 BY: SHEET: • % ,./---Yic1`- f.7,!'."7.(-7.ift Li/.Air.— 1 4v Gil j ijr' ..--f�%•-�%/!!J /�' 1 / . .-=f /[: •+.J7 :(,..^ C.. .. - fir=_ . ___, • . -- ---" R,, ` 4.:,i: . 5D / :: LT9 ii s T :"ii _i ' ! e._ -p = -moi. 1 {.. • Ra1 ja : J . r Y I _ f f: . _ f.+ ..biUti i:&-;:14auLS+ , n," .fes t i ��� — _ - _ _ y 6 V f • ENBEEMIIIMINIIIIMEN fi 4 ! I i 1 1 • , , T--7 • , r .. S Nei L,j tri �,/i.j .�; ` (I�t� •" 1 � 1 f , . _ ,r-�x ��rt • • f t _ ` : r_ i.. r• • , 1 1 '. • { . [... F,... )4 • i j ! t � -i 1i t$•J t� :__l. 1 1_.: L ' 1 { 3900 Cover Street Long Beach, CA 90808-1773 562.985.3200 P 562.985.101 1 F www.mhpse.com STRUCTURAL ENGINEERS CALCULATION SHEET DATE: BY: JOB NO: . — C,t4O 1 SHEET: (3 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.1011 F www.mhpse.com t/...,W. _n. -... L.l^ r.. e..\./'�_'.�lt y i. ,;. f w-. g) (( J_ I.1-_ jP�4 t • s a t { } V a r `-•'! _{._- k m# �-}p�J� ( y� ' '/ I i_ t.. 1 v E q444 ..-.t � '}'."+ i j E 6 ? s i � I a ``1 = i I � .>,-M�.$��af�-...s-... ,y /( � p �.1„�c. to `._ ,✓ � _ a_ -y..{ �.3¢ e yea* 1 1 _ I i 9 � ## 1 ,_.___ t_.-.:. .._r. 7_ .. ._. ' __... _.-.i—.�.. t-- t --.-a_-..._�. -j -,{ F _ - - iiifff _ , -... { _ _ _ .,.... €�€ ti _ - t 5 _ r _ a 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.1011 F www.mhpse.com CALCULATION SHEET STRUCTURAL ENGINEERS 3900 Cover Street, Long Beach, CA 90808-1773 562985.3200 P 562.985.1011 F www.mhpse.com SUBJECT: \/0' 10 75' STRUCTURAL ENGINEERS . Si /4.- ori 77Ak Elfd" CALCULATION SHEET[[�� DATE: JOB NO: 00C18 BY: fs 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.1011 F www.mhpse.com STRUCTURAL ENGINEERS SUBJECT: V6LOA N Jnic, _7 _ A�wC J— P DATE: CALCULATION /SHEET JOB NO: (706416 BY: SHEET: py( 1 .1. 5 f J _ � k i ...11 J l _ t 7 [ i d : - }_ 1 r { 7 i i . +! t - ' • :. !'� 1 P 4 f ; .} jp + ,...-j. { 3 ij n9 f yy {{ {}�/I p} qy,� I. 4-- f < 4' _--'-'<4 _- o- I\ IGS _ 11 ' er " c,,...--, , ✓T (_"�. {.. { p • JI�_a.:.r I I 1 °_- _ € �... r-- ..-... i •, 1 �. _`�_�.. e //1 -_, 11 �% 1 `•-fi' i ! .. ( _.�_ � )tr / ��j l l.l�` - L iii' } ! ..µ ti pp € t C� � tU 11 (l(i/'� ace jppp//1//(/' \-rl�. V \ I W l� 1� J_'� `tf .. Z.7/ I...� ..�... L 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.1011 F v✓ww.mhpse.com STRUCTURAL ENGINEERS SUBJECT: i n 914/4 Ws CALCULATION SHEET DATE: BY: JOB NO: SHEET: 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.1011 F www.mhpse.com STRUCTURAL ENGINEERS `" SUBJECT: guy CF-�'� Y r.J./r t' DATE: ! T //2/.6/42' BY: CALCULATION SHEET JOB NO: /7"4008 SHEET: 3900 Cover Street, Long Beach, CA 90808-1773 562.985.3200 P 562.985.101 1 F www.mhpse.com EMITcOORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0090 PROJECT NAME: RED DOT SITE ADDRESS: 745 ANDOVER PARK E DATE: 04/17/17 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �- 4J4 art i �r�ill Building Division M Public Work Nil AM' 11- f l 5—H Fire Prevention Planning Division Ei9 Structural Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 04/18/17 Structural Review Required DATE: ❑ APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: nApproved with Conditions ❑ Denied (corrections entered in Reviews) I Notation: (ie: Zoning Issues) 05/16/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SAUNDERS CONSTRUCTION INC Page 1 of 2 Nome Espafiol Contact Search L&I A-% Index Help Safety & Health Claims & Insurance Workplace Rights 0114, Washington State Department of Labor & Industries SAUNDERS CONSTRUCTION INC Owner or tradesperson Principals SAUNDERS, STEVEN W, PRESIDENT ZAMORA, AMBER MARIE, SECRETARY HILL, SUSAN JOAN, TREASURER CASILLAS, PATRICIA, AGENT Doing business as SAUNDERS CONSTRUCTION INC WA UBI No. 602 518 261 1760 MONROVIA AVE UNIT A-1 COSTA MESA, CA 92627 949-646-0034 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SAUNDCI953ND Effective - expiration 08/04/2005— 08/04/2017 Bond ............ American Contractors Indem CO Bond account no. 100090721 $12,000.00 Received by L&I Effective date 07/20/2009 08/01/2009 Expiration date Until Canceled Insurance ............................ Zurich American Ins Co $1,000,000.00 Policy no. GLO9184846-03 Received by L&I Effective date 04/07/2017 04/01/2017 Expiration date 04/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. My 1.:&1 Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602518261 &LIC=SAUNDCI953ND&SAW= 5/17/2017 SAUNDERS CONSTRUCTION INC L&I Tax debts No L&I fax debts are recorded for this contra r license during the previous 6 year period, but some is may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 096,545-00 ............................... Doing business as SAUNDERS CONSTRUCTION INC Estimated workers reported Quarter 1 of Year 2017 "4 to 6 Workers" L&I account representative T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 CO Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602518261 &LIC=SAUNDCI953ND&SAW= 5/17/2017 ABBREVIATIONS: CODES/INSTITUTIONS/ASSOCIATIONS ACI AMERICAN CONCRETE INSTITUTE AF&PA (NDS) AMERICAN FOREST & PAPER ASSOCIATION (NDS) AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE APA -EWA ASCE ASTM AWS CBC CRSI DSA IBC NDS SDI SJI SSMA SYMBOLS > t 0 0 APA -ENGINEERED WOOD ASSOCIATION AMERICAN SOCIETY OF CIVIL ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS AMERICAN WELDING SOCIETY CALIFORNIA BUILDING CODE CONCRETE REINFORCING STEEL INSTITUTE DIVISION OF THE STATE ARCHITECT INTERNATIONAL BUILDING CODE NATIONAL DESIGN SPECIFICATIONS STEEL DECK INSTITUTE STEEL JOIST INSTITUTE STEEL STUD MANUFACTURERS ASSOCIATION POUND, NUMBER, QUANTITY AT LESS THAN GREATER THAN PLUS OR MINUS DEGREE DIAMETER ABBREVIATIONS AB ADDL ADJ ALT APPROX ARCH BLKG BM BOT BTWN CALCS CG CL CLR CMU COL CONC CONN CONT db DBL DIA DIAG DIM DWG (E) EA. EF ELEC EMBED EOR EQ EQUIP EW EXP EXT FDN FTG GA GALV HEX HORIZ ANCHOR BOLT ADDITIONAL ADJACENT ALTERNATE APPROXIMATE, APPROXIMATELY ARCHITECT, ARCHITECTURAL BLOCKING, BLOCK BEAM BOTTOM BETWEEN CALCULATIONS CENTER OF GRAVITY CENTERLINE CLEAR, CLEARANCE CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECT, CONNECTION CONTINUOUS BAR DIAMETER (REBAR) DOUBLE DIAMETER DIAGONAL DIMENSION DRAWING EXISTING EACH EACH FACE ELECTRICAL EMBED, EMBEDDED, EMBEDMENT ENGINEER OF RECORD EQUAL EQUIPMENT EACH WAY EXPANSION EXTERIOR FOUNDATION FOOTING GAUGE GALVANIZE HEXAGONAL HORIZONTAL ID INSIDE DIAMETER INFO INFORMATION IOR INSPECTOR OF RECORD K KB3 KB -TZ KSF KSI KIPS (1000#) HILTI KWIK BOLT 3 (ANCHOR) HILTI KWIK BOLT TZ (ANCHOR) KIPS PER SQUARE FOOT KIPS PER SQUARE INCH LBS LL LLH LLV LOCS LONG LTWT MANUF MAX MECH MID MIN (N) N/A NTS OC OP PERP PLF PSI QTY POUNDS LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATIONS LONGITUDINAL LIGHTWEIGHT MANUFACTURER MAXIMUM MECHANICAL MIDDLE MINIMUM NEW NOT APPLICABLE NOT TO SCALE ON CENTER OPERATING PERPENDICULAR POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH QUANTITY REINF REINFORCING REQD REQUIRE, REQUIRED SCHED SEOR SIM SMS SQ SS STAGG STIFF STIRR STRUC SYM T&B THK THRU TRANS TYP UNO VERT VIF W/ W/O WP WT SCHEDULE STRUCTURAL ENGINEER OF RECORD SIMILAR SHEET METAL SCREW SQUARE STAINLESS STEEL STAGGER STIFFEN, STIFFENER STIRRUP STRUCTURAL SYMMETRICAL TOP & BOTTOM THICK, THICKNESS THROUGH TRANSVERSE TYPICAL UNLESS NOTED OTHERWISE VERTICAL VERIFY IN FIELD WITH WITHOUT WORK POINT WEIGHT STRUCTURAL STEEL SHAPES Cx HSS Lx MCx Mx STD PIPE Sx WTx, STx Wx X-STRG XX-STRG STANDARD CHANNEL HOLLOW STRUCTURAL SECTIONS ANGLE MISCELLANEOUS CHANNEL M SHAPES STANDARD PIPE S SHAPES STRUCTURAL TEES W SHAPES EXTRA STRONG PIPE DBL EXTRA STRONG PIPE GENERAL STRUCTURAL NOTES: DESIGN CRITERIA: CODE OF RECORD: 2015 EDITION, INTERNATIONAL BUILDING CODE (IBC) DESIGN LOADS: ASCE 41-13, SEISMIC EVALUATION AND RETROFIT OF EXISTING STRUCTURES: PERFORMANCE OBJECTIVE 1: (LIFE SAFETY) GROUND MOTION: BSE -1E (225 YR RETURN PERIOD) Sxs = 0.689g Sxl = 0.372g PERFORMANCE OBJECTIVE 2: (COLLAPSE PREVENTION) GROUND MOTION: BSE -2E (975 YR RETURN PERIOD) Sxs= 1.105g Sxl = 0.628g 1. GOVERNING CODE AUTHORITY FOR THIS PROJECT: CITY OF TUKWILA DEPARTMENT OF BUILDING AND SAFETY AND IS REFERRED TO AS "THE GOVERNING AGENCY" IN THESE AND OTHER STRUCTURAL NOTES SECTIONS. 2. GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB, EXCEPT WHERE THEY MAY DIFFER WITH DETAILS AND NOTES ON OTHER SHEETS, IN WHICH CASE THE DETAILS AND NOTES ON OTHER SHEETS SHALL GOVERN. DETAIL MARKS WITH "SIM" NOTED INDICATES THAT DETAIL CONTAINS MODIFIED INFORMATION APPLICABLE TO THE CONDITION REFERENCED. 3. OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE SEOR PRIOR TO PROCEEDING WITH ANY WORK INVOLVED. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE SEOR AND SHALL BE RESOLVED PRIOR TO PROCEEDING WITH THE WORK. 5. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST CURRENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE SEOR SO THAT THE PROPER REVISION MAY BE MADE. MODIFICATIONS OF CONSTRUCTION DETAILS SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE SEOR AND THE GOVERNING AGENCY. 6. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OR SEQUENCE OF CONSTRUCTION, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING, SHORING AND LAYDOWN OF CONSTRUCTION MATERIALS. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY CONSTRUCTION LOADING, INCLUDING LOADING FROM EQUIPMENT SUCH AS SKIP LOADERS, SCISSOR LIFTS, ETC., ON ALL PORTIONS OF THE STRUCTURE, WHETHER ELEVATED OR ON -GRADE. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE PATH -OF -TRAVEL FOR MOVING PERMANENT EQUIPMENT TO ITS FINAL LOCATION, INCLUDING THE EFFECTS OF TEMPORARY LOADING AS THE EQUIPMENT IS INSTALLED. THE CONTRACTOR MAY USE THE "DESIGN LOADS" INFORMATION PROVIDED ABOVE WHEN CONSIDERING TEMPORARY CONSTRUCTION LOADING CONDITIONS. 8. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE SEOR SHALL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OF THE CONSTRUCTION PROCEDURES. ANY SUPPORT SERVICES PERFORMED BY THE SEOR DURING THE CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED SPECIAL INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE SEOR, WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER COMPLETION OF CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, BUT DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 9. ASTM DESIGNATIONS AND ALL STANDARDS REFER TO THE LATEST AMENDMENTS. 10. WHEN THE ALLOWANCE FOR SUBSTITUTION OF A SPECIFIED MATERIAL OR PRODUCT DESIGNATION IS IMPLIED ON THE DESIGN DRAWINGS BY THE USE OF THE WORDS "OR APPROVED EQUAL", APPROVAL SHALL BE OBTAINED FROM THE SEOR AND THE GOVERNING AGENCY PRIOR TO FABRICATION OR INSTALLATION OF THE SUBSTITUTED MATERIAL OR PRODUCT. 11. DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON DRAWINGS. 12. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION WHEN SO SPECIFIED ON THE CONTRACT DRAWINGS AND SPECIFICATIONS FOR CERTAIN TYPES OF WORK. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE, TO THE SATISFACTION OF T EGOVERNING HAGEN CY FOR INSPECTION OF THE PARTICULAR C LAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE SEOR AND TO THE GOVERNING AGENCY. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE SEOR AND TO THE GOVERNING AGENCY. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS KNOWLEDGE, IN CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISION OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED ON THE PLANS OR IN THE PROJECT SPECIFICATIONS. 13. UNLESS SPECIFICALLY SHOWN ON THESE PLANS, NO STRUCTURAL MEMBER (BEAM, COLUMN, SHEARWALL, GRADE BEAM, ETC.) SHALL BE CUT, DRILLED OR NOTCHED WITHOUT PRIOR AUTHORIZATION FROM THE SEOR AND THE GOVERNING AGENCY. STRUCTURAL AND MISCELLANEOUS STEEL: 1. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATION (UNLESS NOTED OTHERWISE): A. WIDE FLANGE SECTIONS (W,WT) ASTM A-992 FY=50KSI B. CHANNELS AND MISC SHAPES (C,MC,S,M) ASTM A-36 FY=36KSI C. ANGLES AND PLATES ASTM A-36 FY=36KSI D. PIPE (STD,X-STRG,XX-STRG) ASTM A-53 TYPE E, GR BFY=35KSI E. HSS TUBE (SQ,RECTANG) ASTM A-500, GR B FY=46KSI F. HSS TUBE (ROUND) ASTM A-500, GR B FY=42KSI 2. STEEL HSS TUBES SHALL CONFORM TO ASTM A-500 GR B SEAMLESS. SULFUR CONTENT SHALL BE LESS THAN OR EQUAL TO 0.05%. 3. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND SEOR FOR REVIEW PRIOR TO FABRICATION AND ERECTION, IN ACCORDANCE WITH NOTES A AND B OF GENERAL STRUCTURAL NOTES. 4. A TOLERANCE OF + 0, -1/4 INCH SHALL BE APPLIED TO ALL SPECIFIED CAMBERS. 5. ALL STEEL EXPOSED TO MOISTURE OR WEATHER SHALL BE HOT -DIPPED GALVANIZED, UNLESS NOTED OTHERWISE. 6. PAINTING OF STRUCTURAL STEEL SHALL COMPLY WITH THE REQUIREMENTS PER AISC 360 AND IBC SECTION 2203.2. STRUCTURAL STEEL EMBEDDED IN CONCRETE OR MASONRY SHALL BE UNPAINTED. 7. HOT -DIP GALVANIZE OR PROVIDE THREE-INCH (3") MINIMUM CONCRETE COVER AROUND ALL STRUCTURAL STEEL BELOW GRADE. 8. BOLTS SHALL CONFORM TO ASTM A-307, UNLESS NOTED OTHERWISE. BOLTS EMBEDDED IN CONCRETE OR MASONRY SHALL CONFORM TO ASTM F-1554 GR 36 AND SHALL BE HEADED -TYPE. DO NOT USE J -TYPE BOLTS. THREADED RODS SHALL CONFORM TO ASTM A-36, EXCEPT WHERE USED AS A POST -INSTALLED ANCHOR. 9. UNLESS NOTED OTHERWISE, ALL BOLTS SHALL BE INSTALLED "SNUG TIGHT". THE SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES OF THE JOINT ARE IN FIRM CONTACT. BOLTS OF SLOTTED CONNECTIONS SHALL BE INSTALLED "FINGER TIGHT' ONLY, WITH THREADS SPOILED. THE FINGER TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN THE WASHER AND BOLT HEAD ARE IN FULL CONTACT WITH WEB OR SHEAR TAB. WHERE SLOTTED CONNECTIONS ARE INDICATED THE WASHER SHALL BE PLACED OVER THE SLOTTED HOLE. 10. ALL WELDING SHALL COMPLY WITH AWS SPECIFICATIONS AND SHALL BE PERFORMED BY WELDERS CERTIFIED FOR THE TYPE OF WELDING TO BE PERFORMED. WELDING PROCEDURE SPECIFICATIONS (WPS) SHALL BE PROVIDED FOR EACH WELD TYPE SHOWN ON THE DRAWINGS IN CONFORMANCE WITH AWS D1.1 AND D1.4. EACH WPS SHALL BE REVIEWED BY AN AWS SCWI CERTIFIED INSPECTOR AND SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD (SEOR) FOR REVIEW. IF A WELD ASSEMBLY NOTED ON PLANS DOES NOT FALL WITHIN THE PREQUALIFIED CRITERIA, CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A QUALIFICATION RECORD FOR THE SPECIFIED WELD AS PART OF THE WPS SUBMITTAL. 11. ALL WELDING SHALL BE DONE BY ELECTRIC ARC PROCESS WITH E70XX ELECTRODES. 12. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE, USE MINIMUM SIZE WELDS AS SPECIFIED IN THE AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION, SPECIFICATION SECTION J2.2B. 13. ALL STRUCTURAL FIELD WELDING SHALL REQUIRE SPECIAL INSPECTION BY AN AWS CERTIFIED INSPECTOR APPROVED BY THE GOVERNING AGENCY (WELDING OF MISCELLANEOUS LIGHT -GAUGE MATERIALS SUCH AS METAL STUDS, FURRING CHANNELS, ETC., DOES NOT REQUIRE SPECIAL INSPECTION). 14. SEE SPECIAL INSPECTION NOTES FOR INSPECTION REQUIREMENTS. ALL SHOP WELDING SHALL BE DONE IN THE SHOP OF A LICENSED STEEL FABRICATOR APPROVED BY THE GOVERNING AGENCY OR SHALL REQUIRE SPECIAL INSPECTION BY AN AWS CERTIFIED INSPECTOR APPROVED BY THE GOVERNING AGENCY. FRAMING LUMBER: 1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR -LARCH, WEST COAST (WCDF) OF THE FOLLOWING MINIMUM GRADES (UNLESS NOTED OTHERWISE): A. ALL LUMBER = No. 2 UNLESS NOTED OTHERWISE 2. STRUCTURAL PLYWOOD SHALL BE DOUGLAS FIR CONFORMING TO UNITED STATES PRODUCT STANDARD PS -1-95 EXTERIOR GRADE, MARKED STRUCTURAL I AND SHALL BE STAMPED BY AN APPROVED FABRICATOR. 3. FEATURES OF THE CONSTRUCTION OF HORIZONTAL WOOD DIAPHRAGMS, SHEAR WALLS AND ANY SPECIAL CONNECTIONS WITHIN OR BETWEEN SUCH ELEMENTS SHALL BE INSPECTED AFTER INSTALLATION IN ACCORDANCE WITH THE FOLLOWING INSPECTION STANDARD. INSPECTION MAY BE PERFORMED ON A PERIODIC BASIS PROVIDED ALL FEATURES HAVE BEEN INSPECTED PRIOR TO THE INSTALLATION OF ANY COVERING MATERIALS. THIS INSPECTION SHALL BE DONE BY A SPECIAL INSPECTOR WHEN SHEATHING BOUNDARY NAILING IS CLOSER THAN FOUR INCHES (4") ON CENTER. A. SPECIAL FASTENINGS SHOWN ON THE PLANS, SUCH AS HORIZONTAL DIAPHRAGM AND SHEAR WALL SHEATHING NAILING TO CHORDS, DRAG STRUTS, POST TIE -DOWNS AND BLOCKING ABOVE SHEAR WALLS, SHALL BE INSTALLED. SILLS SHALL BE SECURED AS SHOWN ON THE PLANS. SPECIAL CLIPS, STRAPS, TIE -DOWNS AND OTHER CONNECTIONS WITHIN OR BETWEEN DIAPHRAGMS AND SHEAR WALLS SHALL BE INSTALLED AS SHOWN ON THE PLANS. SPECIAL INSPECTION SERVICES SHALL BE SCHEDULED SO AS TO ALLOW ANY CORRECTIVE WORK TO BE ACCOMPLISHED WITHOUT INTERFERENCE WITH LATER SCHEDULED WORK. 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN, NOTED OR APPROVED BY THE SEOR. 5. MAXIMUM MOISTURE CONTENT FOR ALL STRUCTURAL MEMBERS SHALL NOT EXCEED 19 PERCENT (19%) UNLESS NOTED OTHERWISE. ALL 2x FRAMING SHALL BE STAMPED "S -DRY." ANY LUMBER STAMPED 0S -GREEN" SHALL HAVE A MOISTURE CONTENT OF LESS THAN 19% AT THE TIME OF INSTALLATION AND THE MOISTURE CONTENT SHALL BE TESTED WITH A MOISTURE METER HAVING ONE INCH (1") NEEDLE IN THE PRESENCE OF AN INSPECTOR. 6. BOLT HOLES TO BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS NOTED OTHERWISE. PROVIDE WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. 7. FRAMING HANGERS, CAPS, HOLDOWNS, POST BASES, ANCHORS, CONNECTORS, ETC., SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR APPROVED EQUAL TO BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. 8. NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F-1667 PER IBC SECTION 2303.6. NAILS SHALL BE COMMON WIRE (UNO) AND THE NUMBER OF NAILS CONNECTING WOOD MEMBERS SHALL NOT BE LESS THAN THE AMOUNTS SET FORTH IN THE PREVAILING BUILDING CODE. GALVANIZED COMMON NAILS SHALL BE USED FOR ALL EXPOSED EXTERIOR WOOD. COMMON NAILS SHALL CONFORM TO THE SPECIFICATIONS OF NAIL PROPERTIES SCHEDULE BELOW: NAIL PROPERTIES SCHEDULE DESIGNATION LENGTH WIRE DIAMETER HEAD DIAMETER 6d 2" 0.113" 0266" 8d 2 1/2" 0.131" 0.281" 10d 3" 0.148" 0.312" 12d 3 1/4" 0.148" 0.312" 16d 3 1/2" 0.162" 0.344" 20d 4" 0.192" 0.406" NOTE: 10d COMMON SHORT (2-1/8" LONG) MAY BE USED AT 1/2" AND THINNER OF 10d COMMON (3") OR 8d COMMON (2-1/2"). NAILING THROUGH OUTER PLY OF PLYWOOD. IF PNEUMATIC GUNS BE ADJUSTED TO SATISFY THE ABOVE CRITERIA. PLYWOOD IN LIEU SHALL NOT BREAK ARE USED, THEY SHALL 9. TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF APPROXIMATELY 30 DEGREES WITH THE MEMBER AND STARTED APPROXIMATELY 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. 10. AT PANELIZED ROOF, NO SYSTEMS SHALL BE SUPPORTED FROM SUB PURLINS (i.e. DUCTWORK, ELECTRICAL CONDUITS, SUSPENDED CEILINGS, SPRINKLERS, ETC.) UNLESS NOTED OTHERWISE. 11. STITCHNAILINGFOR DOUBLE 0 OU LE SAWN JOISTS SHALL BE 16d NAILS AT 12" ON CENTER STAGGERED TOP AND BOTTOM. STITCH BOLTING FOR BUILT UP BEAMS (FOUR 2x MEMBERS MAXIMUM) SHALL BE 1/2" DIAMETER MACHINE BOLT AT 18" ON CENTER. STITCH BOLTING FOR FIVE 2x MEMBERS OR MORE SHALL BE 5/8" DIAMETER MACHINE BOLTS AT 18" ON CENTER STAGGERED TOP AND BOTTOM, UNLESS NOTED OTHERWISE. 12. PRE -DRILL ALL LAG SCREW HOLES WITH DIAMETER (D) FOR UNTHREADED SHANK, 40% TO 70% OF D FOR THREADED PORTION. THE THREADED PORTION OF LAG SCREWS SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING WITH A HAMMER. PROVIDE SOAP OR LUBRICANT ON LAG SCREWS OR IN LEAD HOLE TO FACILITATE INSERTION AND PREVENT DAMAGE TO LAG SCREWS OR WOOD SCREWS. POST -INSTALLED ANCHORS: 1. POST INSTALLED ANCHOR NOTES IN THIS SECTION SHALL APPLY TO ALL ANCHORS INSTALLED INTO HARDENED CONCRETE. 2. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S INSTRUCTIONS AND THE APPLICABLE EVALUATION REPORT. 3. LOCATE EXISTING REINFORCING BY NON-DESTRUCTIVE METHODS PRIOR TO DRILLING. EXISTING REINFORCING SHALL NOT BE CUT. IF REINFORCING IS ENCOUNTERED, ADJUST HOLE LOCATION BY 1.5 TIMES HOLE DIAMETER MINIMUM, 2" MAXIMUM, (BUT NOT CLOSER TO THE EDGE OF CONCRETE), AS REQUIRED TO AVOID REINFORCING. DRILLED HOLES THAT ARE ABANDONED SHALL BE FILLED WITH ADHESIVE OR NON -SHRINK GROUT. 4. HOLES FOR INSTALLATION OF THE EXPANSION ANCHOR, THREADED ROD OR REINFORCING BAR SHALL BE DRILLED USING A DRILL THAT HAS A CARBIDE -TIPPED BIT THAT COMPLIES WITH ANSI B212.15. A REBAR CUTTING DRILL BIT IS NOT ALLOWED. 5. CONTRACTOR SHALL USE APPROPRIATE EQUIPMENT AND METHODS AS REQUIRED TO PROVIDE DRILLED HOLES FOR POST -INSTALLED CONCRETE ANCHORS IN ACCORDANCE WITH APPLICABLE STANDARDS, MANUFACTURER'S RECOMMENDATIONS, AND QUALIFYING (ICC) TEST REPORTS. CARE SHALL BE TAKEN TO PREVENT OVERSIZING, OVALING, AND/OR BLOW-OUT THROUGH THE BACK FACE OF THE DRILLED MEMBER. IF OVERSIZING, OVALING, AND/OR BLOW-OUT OCCURS, THE EMPLOYED EQUIPMENT AND METHODS SHALL BE DISCONTINUED. ADDITIONAL DRILLING SHALL NOT BE RESUMED UNTIL THE SEOR HAS PROVIDED APPROVED REPAIR PROCEDURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF ALL SUCH REPAIRS. WHEN RESUMING DRILLING, THE CONTRACTOR SHALL MODIFY THE PROCEDURES AS NECESSARY TO PREVENT FURTHER DAMAGE. 6. HOLES SHALL BE CLEANED OF DUST AND DEBRIS, USING A WIRE BRUSH AND COMPRESSED AIR OR MANUFACTURER'S BLOW-OUT BULB (AS PER MANUFACTURER'S RECOMMENDATIONS) AS REQUIRED TO REMOVE PARTICULATE DEBRIS AND TO ACHIEVE A RELATIVELY DUST -FREE SURFACE. CLEANLINESS OF DRILLED HOLES SHALL BE VERIFIED AND DOCUMENTED BY A SPECIAL INSPECTOR. 7. OIL, SCALE, AND RUST SHALL BE REMOVED FROM THE EXPANSION ANCHOR, THREADED ROD OR REINFORCING BAR PRIOR TO INSTALLATION. 8. APPROVED ADHESIVE ANCHOR SYSTEMS (AND THREADED ROD) AND EVALUATION REPORTS ARE AS FOLLOWS: HILTI HIT -RE 500-V3 (ASTM A193 GRADE B7) ESR -3814. 9. SEE SPECIAL INSPECTION NOTES FOR INSPECTION REQUIREMENTS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION OF ADHESIVE ANCHORS. THE SPECIAL INSPECTOR SHALL OBSERVE AND RECORD DATA AS SPECIFIED IN THE "SPECIAL INSPECTION" SECTION OF THE APPLICABLE EVALUATION REPORT. 10. EFFECTIVE EMBEDMENT DEPTH FOR POST INSTALLED ANCHORS SHALL BE NOTED ON PLAN. STRUCTURAL OBSERVATION: 1. THE STRUCTURAL ENGINEER OF RECORD (SEOR), OR HIS/HER DESIGNATED ENGINEER, SHALL PROVIDE VISUAL STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS AND SPECIFICATIONS AT SIGNIFICANT CONSTRUCTION STAGES AND AT COMPLETION OF THE STRUCTURAL SYSTEM, AS REQUIRED BY IBC SECTION 1709 AND AS DEFINED IN IBC SECTION 1702. WRITTEN REPORTS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE OR HIS DESIGNEE FOR DISTRIBUTION TO THE SPECIAL INSPECTOR, CONTRACTOR AND BUILDING OFFICIAL. 2. THE STRUCTURAL OBSERVER SHALL SUBMIT A WRITTEN STATEMENT TO THE GOVERNING AGENCY THAT THE SITE VISITS HAVE BEEN MADE. SUCH REPORTS SHALL IDENTIFY ANY OBSERVED DEFICIENCIES, WHICH TO THE BEST OF THE STRUCTURAL OBSERVER'S KNOWLEDGE HAVE NOT BEEN RESOLVED. AT THE COMPLETION OF THE STRUCTURAL SYSTEM THE STRUCTURAL OBSERVER SHALL PROVIDE A FINAL OBSERVATION REPORT INDICATING THAT TO THE BEST OF HIS/HER KNOWLEDGE ALL OBSERVED DEFICIENCIES HAVE BEEN RESOLVED AND THE STRUCTURAL SYSTEM GENERALLY CONFORMS TO THE APPROVED PLANS AND SPECIFICATIONS. 3. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY OF THE INSPECTIONS BY THE BUILDING OFFICIAL AS REQUIRED BY IBC SECTION 109, SPECIAL INSPECTIONS REQUIRED BY IBC SECTION 1704, OR ANY OTHER INSPECTION REQUIRED BY OTHER SECTIONS OF THE CODE OR AS NOTED ELSEWHERE IN THE CONTRACT DOCUMENTS. THE STRUCTURAL OBSERVER DOES NOT HAVE THE AUTHORITY TO APPROVE COVERING OF CONSTRUCTION AND HIS/HER POSITIVE DISPOSITION OF THE OBSERVATION REPORT DOES NOT WARRANT THAT THE CONSTRUCTION WILL PASS THE BUILDING OFFICIAL'S INSPECTION. 4. STRUCTURAL OBSERVATION FOR THIS PROJECT SHALL BE PROVIDED BY MHP STRUCTURAL ENGINEERS, INC.; 3900 COVER STREET, LONG BEACH, CALIFORNIA, 90808; TELEPHONE (562) 985-3200; FAX (562) 985-1011. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION SCHEDULE AND SHALL NOTIFY THE STRUCTURAL OBSERVER NO LESS THAN THREE (3) BUSINESS DAYS IN ADVANCE OF REQUIRED OBSERVATIONS. FAILURE OF THE CONTRACTOR TO PROVIDE ADEQUATE NOTIFICATION MAY RESULT IN DELAYS DUE TO CORRECTIVE WORK OR REMOVAL OF SUBSEQUENT WORK TO ALLOW ADEQUATE OBSERVATION. REMOVAL AND REPLACEMENT OF ANY FINISHED WORK AND/OR FRAMING DAMAGED BY THE REMOVAL PROCESS OR AS REQUIRED FOR CORRECTIVE ACTION RESULTING FROM INADEQUATE NOTIFICATION SHALL BE AT THE CONTRACTOR'S EXPENSE. 6. THE STRUCTURAL OBSERVER SHALL AS A MINIMUM PERFORM STRUCTURAL OBSERVATION AT THE FOLLOWING STAGES OF CONSTRUCTION (CONSTRUCTION STAGES AND ELEMENTS/CONNECTIONS TO BE OBSERVED): A. COMPLETION OF STRUCTURAL SYSTEM SPECIAL INSPECTION 1. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION FOR CERTAIN TYPES OF WORK WHEN SO SPECIFIED IN THE CONTRACT DOCUMENTS AND PROJECT SPECIFICATIONS. THESE SPECIAL INSPECTIONS SHALL BE IN ADDITION TO AND COMPLEMENTARY WITH THE INSPECTIONS PROVIDED BY THE GOVERNING AGENCY. 2. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 3. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE DESIGN DRAWINGS, SPECIFICATIONS AND APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL CONTRACTOR FOR CORRECTION AND THEN, IF UNCORRECTED, TO THE ATTENTION OF THE STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE SPECIAL INSPECTOR AND SCHEDULE THE SPECIAL INSPECTIONS WITH ADEQUATE TIME TO ADDRESS ANY AND ALL POTENTIAL DISCREPANCIES PRIOR TO PROCEEDING WITH SUBSEQUENT WORK THAT COVERS OR OTHERWISE MAKES INACCESSIBLE ANY WORK IDENTIFIED AS DEVIATING FROM THE PROJECT REQUIREMENTS. 4. THE SPECIAL INSPECTOR SHALL FURNISH REGULAR INSPECTION REPORTS TO THE STRUCTURAL ENGINEER OF RECORD AND THE GOVERNING AGENCY IDENTIFYING THE WORK INSPECTED AND ANY UNCORRECTED DISCREPANCIES FROM THE CONSTRUCTION DOCUMENTS. AT THE CONCLUSION OF THE PROJECT OR THE SPECIAL INSPECTORS ASSIGNED SCOPE OF WORK, THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF HIS OR HER KNOWLEDGE, COMPLETED IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS (INCLUDING APPROVED RFI'S, ADDENDUMS, ETC.) AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE AND OTHER APPLICABLE REGULATIONS IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. 5. SPECIAL INSPECTIONS INDICATED BELOW SHALL BE PROVIDED IN EITHER A CONTINUES OR PERIODIC CAPACITY, AS DEFINED BELOW, AS REQUIRED BY THE INDIVIDUAL CODE OR REFERENCED STANDARD. 6. CONTINUOUS - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. FOR STRUCTURAL STEEL, CONTINUOUS INSPECTION IS FURTHER DEFINED SUCH THAT INSPECTION SHALL TAKE PLACE ON EACH ELEMENT TO BE INSPECTED (I.E. EACH BOLT OR WELD). 7. PERIODIC - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. FOR STRUCTURAL STEEL, PERIODIC INSPECTION IS FURTHER DEFINED SUCH THAT ITEMS ARE OBSERVED ON A RANDOM BASIS. REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION PER IBC TABLE 1705.3 VERIFICATION AND INSPECTION CONTINUOUS DURING TASK LISTED PERIODICALLY DURING TASK LISTED REFERENCE FOR CRITERIA MISC. STANDARDS IBC 1. INSPECTION OF ANCHORS POST -INSTALLED IN HARDENED CONCRETE MEMBERS. (FOOTNOTE A) - X ACI 318: 3.8.6, 8.1.3, 21.2.8 1909.1 FOOTNOTE A - SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION ARE INCLUDED IN THE RESEARCH REPORT FOR EACH ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 3552 OR OTHER QUALIFICATION PROCEDURES. THESE SPECIAL INSPECTION REQUIREMENTS SHOULD BE FOLLOWED. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, CONTACT STRUCTURAL ENGINEER FOR SPECIAL INSPECTION REQUIREMENTS PRIOR TO PROCEEDING WITH THE WORK. PROJECT SPECIFIC SPECIAL INSPECTION MEASURES SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK. PROJECT LOCATION 745 ANDOVER PARK EAST TUKWILA, WA 98188 VICINITY EMAP QRS xe SITE PLAN .4. SCALE: NONE SCOPE OF WORK THIS PROJECT IS A VOLUNTARY SEISMIC STRENGTHENING OF THE WALL ANCHORAGE SYSTEMS TO REDUCE THE POTENTIAL FOR STRUCTURAL DAMAGE IN AN EARTHQUAKE. FILE COP Permit No. oohs Plan review pprov9l is subject to errors• . Approval r and ur"=S:�s<:�;. of Construction/ documents does not u�. .� �.�.;. authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION No chanoa s REViSiONS shall be mace to the of work tvithoilt prior Son ' T�'n„ia Building` approval of I. NOTE: r;aviSi,.,! IJ will require Division. and may include additil plan new fees, pian submittal SEPARATE PERMIT REQUIRED FOR: 1114tethaniad 141ectrlc aI ,tPl mbing 'etas Piping City of Tukwila tBUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 04 2017 Citi of Tukwila BUILDING DIVISION. RECEIVED CITY OF TUKWILA APR 1 3 2017 PERMIT CENTER STRUCTURAL ENGINEER STRUCTURAL ENGINEERS 3900 Cover Street Long Beach, CA 90808 562.985.3200 P 562.985.1011 F Voluntary 0 Seismic Strengthening 745 Andover Park East Tukwila, WA 98188 o ISSUE DATE: 01-04-2017 DESCRIPTION DATE a_ coco CLIENT REVIEW 01-27-2017 BUILDING DEPT SUBMITTAL 03-13-2017 IEXPIRES 09-10-2017 JOB NUMBER: 17-0008-00 DRAWN: JA/GL DESIGNED: ERB CHECKED: KDO SCALE: AS NOTED w STRUCTURAL NOTES AND ABBREVIATIONS wS1 m Z w ■ 6 Cei TYP AT EA PURLIN AS SHOWN ROOF FRAMING PLAN SCALE: 1/16" =1'-0" TYP @ 6'-0"OC 1 AT SUB-PURLIN AS SHOWN �IAX S TYP AT GLB AS SHOWN = II 5118"x371/2" GLB (E) 6 314"x34 1/2" GLB II '.I CO C9 r- 0;7 !n (E) 6 3/4"x36" GLB CO -J N M x OD icy TYP ALONG GRID B AS SHOWN E) 6 314"x36" GLB w (E) 6 3/4"x40 1/2" GLB CO -J CD x co 10 w 51/8"x371/2" GLB 5 118"x37 1/2" GLB (E) 4x14 PURLINS @ 8'-0"OC TYP 51/8"x371/2" GLB W 51/8"x371/2" GLB E 6 3!4"x36" GLB 0) c7 !f) UJ (E 6 3/4"x34 112" GLB CO _m _J CO m 0 9 0 X CO CO r7 x 5t M X 0 1L) c1 J CD N 1`+ M !n (E) 6 314"x42" GLB I 1 CO J CD N r- X JE) 6 3!4"x42" GLB -J TYP @ 6'-0"OC MAX AT SUB -PURLINS AS SHOWN (E) 6 3/4"x 25 19 GLB CO co 10 (E) 6 314"x40 1/2" GLB 2x SUB -PURLINS/ @ 24" 0CjYl -/ 10 CO J CO X CO !n w co m Us C: (j X X M 10 En �7 (E) 6 3/4"x 77 271/2 GLB 3 5 1/8"x37 1/2" GLB w 5 1/8"x37 1/2" GLB w (E) 6 3/4"x 271 GLB CO (3 CV X 03 !n (E) 6 3/4"x42" GLB TYP 24'OC AT GLB'S AS SHOWN co J (9 1E)51/8"x371/ H (E) 6 3/4"x42" GLB .I !C) �� lu E 6 3/4"x42" GLB 13'-O" E 6 3/4"x40 1/2" GLB (E) 6 3/4"x 27 1/ GLB 14'-6" 5 1/8"x37 1/2" GLB m -J O M (E) 4x16 PURLINS @ 8'-O"OC TYP UNO CO J (7 X CO 10 (E) 6 3/4"x42" GLB (E) 51/8"x371/2" GLB 5118"x30" GLB (E) 6 3/4"x 2519 GLB 0, J Ca N X 0, !n CO J X co 1�] w CO J 0 01 M X 0, (0 (E) 6 314"x 271 /9 GLB TYP AT GLB HINGE SPLICE 0, co J CD (7 _ fV 1-X M X -60 D in 10 LU) (E) 6 3/4"x 27 1 51/8"x371/2" GLB w 14'-6" (E) 6 3!4"x 251/2 GLB ((E 6 3/4"x401/2" GLB GLB (E) 51/8"x37 1/2" GLB (E) 6 314"x 271!2 GLB ) 51/8"x371/2" GLB CO J 0 N X 0, (E) 6 3/4"x40 1/2" GLB -J J (.9 CO 10 CO -J C7 0, M X .60 10 (E) 6 3!4"x42" GLB 5 1/8"x37 1/2" GLB 1,1 (E) 6 3!4"x42" GLB 51/8"x371/2" GLB 5 1/8"x37 1/2" GLB UJ w E' 6 3/4"x42" GLB 5 1/8"x37 1/2" GLB CO -J CD M (E) 6 3/4"x34 1/2" GLB (E) 6 314"x36" GLB 51/8"x371/2" GLB w H (E) 6 314"x36" GLB monlo 0111. (E) 4x14 PURLINS = 8'-O"OC TYP E)51/8"x371/2" GLB TYP ALONG GRID S AS SHOWN 14'-6" CD ti 153!0 5 1/8"x37 1/2" GLB 14'-6" 13'-0" w) (E) 6 3/4"x 251/.2 GLB _1 (9 Ri 0, M X 0, 10 E 6 3/4"x40 1/2" GLB E 6 314"x34112" GLB cn m -' Ti 0 CD D E) CO X CO X X CO b CO L') - 10 - 1,7 CO CO m CD D (J7 OO D CO CO X X CO W b t:,L7 _ L, __. 2x SUB -PURLINS LU u w 8 24"OC; TYP CO -J (9 0 CO CO 10 CO -J (7 M m J (9 M X 0, 10 ( —il 11 11 11 ÷-41-7-11-41 FI ----4I 11 TYP AT EA PURLIN AS SHOWN C TYP AT GLB AS SHOWN UNO TYP 6'-0"OC MAX AT SUB -PURLINS AS SHOWN SIM N ti O d N O N 0 N 0 N 0 0 N 0 O N 0 N i 1 ROOF FRAMING PLAN NOTES 1. ALL CONSTRUCTION IS NEW UNLESS OTHERWISE NOTED AS EXISTING OR (E). EXISTING CONSTRUCTION IS AS SHOWN FADED. NEW CONSTRUCTION IS AS SHOWN SOLID AND IS REFERENCED BY DETAILS AND NOTES. 2. EXISTING CONDITIONS ARE AS SHOWN TO THE BEST OF OUR KNOWLEDGE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ACTUAL CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THOSE AS SHOWN ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING. 3. SEE GENERAL NOTES SHEET S1.0 FOR APPLICABLE NOTES REGARDING THE VARIOUS CONSTRUCTION ELEMENTS AS SHOWN ON PLAN. 4. == INDICATES NEW STRENGTHENING ANCHORS, SEE SHEET S3.0 FOR APPLICABLE STRENGTHENING DETAILS. FOR HOLDOWN ANCHOR INSTALLATION, SEE DETAIL 8 ON SHEET S3.0. 5. CONTRACTOR TO COORDINATE LOCATION AND INSTALLATION OF ANCHORS WITH EXISTING CONDITIONS. WOOD SHIMS AND/OR ADDITIONAL WOOD MEMBERS AND CONNECTORS MAY BE REQUIRED IF EXISTING WOOD MEMBERS DO NOT LINE-UP. CONTACT ENGINEER IF OFFSET REQUIRING SHIMS IS GREATER THAN 2". IF OFFSET IS LESS THAN 2" PROVIDE 2x4 x8'-0" LONG SHIMS AS REQUIRED (MINIMUM). NAIL SHIMS TO WOOD ROOF MEMBERS WITH 2 ROWS OF 10d @ 4"OC. 6. DRILL BOLT HOLES WITH DRILLING JIG AS REQUIRED TO EN$URE HOLES ARE PERPENDICULAR TO FRAMING MEMBER. 7. SUB-PURLIN ANCHORS SHALL BE INSTALLED PER PLANS; HOWEVER, LOCATIONS AS SHOWN MAY NEED TO BE ADJUSTED TO PREVENT INTERFERENCE WITH EXISTING DUCTS, EQUIPMENT, ETC. NOTIFY ENGINEER PRIOR TO ADJUSTING LAYOUT. 8. VERIFY ALL PERTINENT DIMENSIONS AND POTENTIAL INTERFERENCES WITH MECHANICAL EQUIPMENT, PIPES, DUCTS, ETC., PRIOR TO INSTALLATION OF ANCHORS. PROVIDE SHIMS AND/OR RELOCATE INTERFERENCES AS REQUIRED FOR INSTALLATION. 9. CONTRACTOR TO PROVIDE GALVANIZED BOLTS, NUTS AND PLATES FOR ALL EXTERIOR CONDITIONS. 10. STEEL PLATES SHALL BEAR UNIFORMLY ON EXTERIOR WALL SURFACE. PROVIDE NON -SHRINK GROUT BETWEEN PLATES AND WALL SURFACE WHERE WALL SURFACE IS IRREGULAR. CONTRACTOR TO SUBMIT PRODUCT INFORMATION FOR APPROVAL PRIOR TO INSTALLATION. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 04 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 3 eo APERMIT n CENTER STRUCTURAL ENGINEER STRUCTURAL ENGINEERS 3900 Cover Street Long Beach, CA 90808 562.985.3200 P 562.985.1011 F Voluntary Seismic Strengthening 745 Andover Park East Tukwila, WA 98188 2ISSUE DATE: 01-04-2017 1. ® DESCRIPTION • BUILDING DEPT SUBMITTAL 03-13-2017 (02 CLIENT REVIEW DATE 01-27-2017 a c0 !EXPIRES; 09-10-2017 0 LL JOB NUMBER: Lj 17-0008-00 DRAWN: JA/GL DESIGNED: ERB CHECKED: KDO SCALE: AS NOTED ROOF FRAMING PLAN S2.0 (1 /S3.0) • UNLESS SPECIFICALLY NOTED OTHERWISE ON PLAN OR DETAIL, THIS DETAIL SHALL APPLY TO ALL HOLDOWN/WALL ANCHORS. • WHERE APPLICABLE, INSTALL EPDXY ANCHOR (OR THRU-BOLT) PRIOR TO DRILLING HOLES THRU WOOD MEMBER. IF REBAR OR OTHER OBSTRUCTIONS ARE ENCOUNTERED, NOTIFY ENGINEER PRIOR TO PROCEEDING. • INSTALL HOLDOWN & TIGHTEN NUTS AS INDICATED: STEP 1 INSTALL BOLTS THRU CONNECTOR & WOOD MEMBER STEP 2 TIGHTEN OUTER NUT STEP 3 BACKUP INNER NUT TO LOCK CONNECTOR IN PLACE AT HD5B, HD7B & HD9B, PROVIDE WASHER BETWEEN INNER NUT & HOLDDOWN TO TIGHTEN AGAINST HOLDOWN STIFF PLATES HOLDOWN ANCHOR INSTALLATION SCALE: NONE 6" MAX (E) ROOF SHEATHING CL GLB 6" i MAX SIMPSON HD12 EA SIDE OF (E) GLB & PURLIN W/ 1 1/8"0 THREADED ROD (4 TOTAL PER CONN) 171 fir.t.E1 (E) GLB PER PLAN (E) PIPE COL - *® w (E) PURLIN PER PLAN CONN PER(6/S3.0) CONTINUITY TIE AT GLULAM TO PURLIN SPLIC SCALE: 1" =1'-0" n An An n on 1'-0" n en SOLID WOOD SHIM EA SIDE OF GLB TO ALIGN W/ F/O CONC SECTION A -A PLAN VIEW (E) PURLIN WHERE OCCURS PER PLAN (E) ROOF SHEATHING 0 0 0 0 0 0 PL1/4x3" EA SIDE OF GLB AS SHOWN. PROVIDE (4)-3/4"0 FULLY THREADED RODS SET IN EPDXY (5" EMBED) INTO EA SIDE OF CONC PIER (8 TOTAL) & (6)-314"0 THRU BOLTS AT GLB (E) NAILER /, , O O O O 0 0 (E) GLB PER PLAN (E) CONC PIER CONTINUITY TIE AT CONCRETE PIER SCALE: 1" =1'-0" SIMPSON HD5B EA SIDE OF SUB-PURLIN ASSEMBLY W/ 5/8"0 THREADED ROD - CONNECTORS TO ALIGN W/ CONNECTORS IN SUB- PURLIN c A (E) ROOF SHEATHING A (E) SUB-PURLIN AS SHOWN ON PLAN, TYP STITCH (N) 2x4 TO (E) SUB-PURLIN W/ (N) 10d @ 6"OC SECTION A -A TYP NOTE: ALL NEW 2x4 MEMBERS SHALL BE D.F. #2, MINIMUM. 10d @ 6"OC (STAGG) (E) SUB PURLIN (E) ROOF SHEATHING (E) NAIL kr is tlf SECTION A -A 1 112" =1'-0" 2x4 SISTER (E) PURLIN SUB -DIAPHRAGM TIE AT SUB-PURLIN SCALE: NONE (E) ROOF SHEATHING GLB 6" MAX (E) GLB PER PLAN, TYP CONTINUITY TIE AT GLULAM SCALE: NONE (E) HINGE CONN (E) ROOF SHEATHING 6" MAX 6" MAX SIMPSON HD9B EA SIDE OF (E) GLB (4 TOTAL PER CONN) W/ 7/8"0 THREADED ROD SIMPSON HD12 EA SIDE OF (E) GLB W/ 1 118"0 THREADED ROD (4 TOTAL PER CONN) (E) DROP-IN GLB PER PLAN (E) BOLTED CONTINUITY TIE CONN TO REMAIN INTACT CONTINUITY TIE AT GLULAM SPLICE SCALE: NONE (E) GLB PER PLAN SIMPSON HD5B EA SIDE OF (E) SUB-PURLIN ASSEMBLY W/ 5/8"0 FULLY THREADED ROD SET IN EPDXY INTO (E) CONC WALL (4 1/2" EMBED) (E) ROOF SHEATHING SUB- PURLIN t 'G (E) SUB-PURLIN AS SHOWN ON PLAN, TYP STITCH (N) 2x4 TO (E) SUB-PURLIN W/ (N) 10d @ 6"OC SECTION A -A NOTE: ALL NEW 2x4 MEMBERS SHALL BE D.F. #2, MINIMUM. 10d @ 6"OC (STAGG) (E) SUB-PURLIN MAX (E) ROOF SHEATHING (E) NAIL `v Ch SECTION A -A 1 1/2" =1'-0" 2x4 SISTER WALL TIE AT SUB-PURLIN SCALE: NONE SIMPSON HD5B EA SIDE OF (E) PURLIN W/ 5/8"0 FULLY THREADED ROD SET IN EPDXY INTO (E) CONC WALL (4 1/2" EMBED) (E) ROOF SHEATHING (E) PURLIN PER PLAN WALL TIE AT PURLIN SCALE: NONE (E) PANEL JOINT - 6" MAX 7"7" VIF 1 VIF -- -N.0 1"J 6" THK VIF G (E) NAILER, TYP (E) CONC WALL PER PLAN (E) STL CHANNEL LEDGER 1 1/2" CLR MIN (DO NOT BLOW THRU BACK SIDE OF WALL. USE NON -IMPACT DRILL FOR LAST ONE -INCH OF HOLE DEPTH IF REQ'D (E) NAILER, TYP (E) CONC WALL PER PLAN (E) STL CHANNEL LEDGER 1 1/2" CLR MIN (DO NOT BLOW THRU BACK SIDE OF WALL. GR. _ USE NON -IMPACT DRILL FOR LAST ONE -INCH OF 6" HOLE DEPTH IF REQ'D THK VIF (E) GLB PER PLAN SIMPSON HD9B (E) PILASTER BELOW 7----- H N w DONOT BLOW THRU BACKSIDE OF WALL AT THRU BOLT (SEE NOTE 10 ON SHEET S2.0) SIMPSON HD9B EACH SIDE OF (E) GLB AS SHOWN. PROVIDE 7/8"0 THRU BOLT W/ SIMPSON BP7/8 BEARING PLATE OR BEARING PL5/16"x3"x3" ON OUTSIDE FACE OF WALL (E) ROOF SHEATHING PLAN VIEW w w (E) GLB PER PLAN WALL TIE AT PILASTER SCALE: NONE D u_ H io (E) CONC WALL PER PLAN (E) CONC WALL PER PLAN (E) LEDGER, TYP SEAL INTERFERENCE BTWN PL & WALL W/ URETHANE CAULKING, TYP FRAMING CONTRACTOR TO PROVIDE GALVANIZED HARDWARE PER NOTE 9 ON SHEET S2.0 i PROVIDE NUT AND CUT WASHER AT INSIDE F/O WALL 71/2" THK 6"THK VIF VIF REVIEWED FOR CODE COMPLIANCE APPROVED MAY 04 2011 City of Tukwila ILDING DIVISION 11 0 (E) PILASTER RECEIVED CITY OF TUKWILA APR 1 a 2017 PERMIT CENTER STRUCTURAL ENGINEER STRUCTURAL ENGINEERS 3900 Cover Street Long Beach, CA 90808 562.985.3200 P 562.985.1011 F Z Voluntary Seismic Strengthening g g 745 Andover Park East Tukwila, WA 98188 o ISSUE DATE: 01-04-2017 o/ I� DESCRIPTION DATE CLIENT REVIEW 01-27-2017 BUILDING DEPT SUBMITTAL 03-13-2017 cia 0 co co 'EXPIRES 09-10-2017 JOB NUMBER: 17-0008-00 DRAWN: W JA/GL DESIGNED: ERB CHECKED: KDO SCALE: AS NOTED W FRAMING SECTIONS AND DETAILS 1S3.O