Loading...
HomeMy WebLinkAboutPermit D17-0124 - BOEING #9-101 - OFFICE RECONFIGURATIONBOEING #9-101-2 9725 E MARGINAL WAY S BLDG 9-101 EXPIRED 01/23/18 D17-0124 Parcel No: Address: City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0003400018 Permit Number: D17-0124 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: Permit Expires On: Project Name: BOEING #9-101 5/24/2017 11/20/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH PO BOX 3707 MC 46-88 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Phone: (253) 740-0214 Phone: (312) 544-2535 Expiration Date: 1/18/2019 DESCRIPTION OF WORK: RECONFIGURATION OF EXISTING OFFICE AREA TO SEURE SPACE IN OFFICE AREA. CONSTRUCTION OF SMALL OFFICE, SERVER ROOM, LARGE MEETING ROOM, AND SECURE SMALL MEETING ROOM, ALONG WITH OPEN OFFICE AREA. Project Valuation: $317,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $5,998.69 Occupancy per IBC: B Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No js(:)Le"--....,(_ Permit Center Authorized Signature: Date: S� —�"► I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grant state or develop of this permit does not presume to give authority to violate or cancel the provisions of any other I laws regulating construction or the performance of work. I am authorized to sign and obtain this and agree to the conditions attached to this permit Vteoki "wimp`Date: /,t r E0 17- Signatur Print N This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 13: Maintain fire extinguisher coverage throughout. 14: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 15: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 18: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 19: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 20: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 21: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 25: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 27: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD 0601 WALL INSULATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 1 �j - n),1.4 Blanket Permit No. 1%'A D005 Date Application Accepted: Date Application Expires: 114 .11 (For office use only) BLANKET PERMIT TENANT IMPROVEMENT APPLICATION **Please Print** FEES: For office use only Existing (square feet) Construction Area (square feet) Amount Receipt No. Building Use Date Building Permit Fee I $ 474' t5 .'24. I R 1 �,l• , l r '/ • iD ,17 Plan Review Fee $ ��) t 5. vi v 295,878 4,155 II -B State Building Surcharge $ 4,50 3id Floor 55,689 0 Total S 6(406/..t11 Office Floors thru SITE INFORMATION: Valuation of Construction: $ 317,000.00 Site Address: Tenant Name: 9725 East Marginal Way So The Boeing Company Description of work: Reconfiguration of Existing Office Area to Secure Space in Office Area. Construction of Small Office, Server Room, Large Meeting Room, and Secure Small Meeting Room, along with Open Office Area. King Co Assessor's Tax No.: VDD,14-0-1,Og4 Suite Number: 9-101 Floor: 2 Per the International Building Code — 2015 Edition 1. Will there be any structural work? Yes X No If yes, please describe: 2. Will there be new rack storage? Yes X.No If yes, a separate permit and plan submittal will be required. 3. Will there be a change in use? Yes If yes, please explain: 4. Existing fire protection: XSprinklers .... Automatic Fire Alarm .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes ).(No If yes, please explain: H:\Applications',Forrts-Applications On Line12016 Applicntions\Blanket Permit TI Application - 7-20 16.docx Revised: July 2016 bh Page 1 of 3 Existing (square feet) Construction Area (square feet) Type of Construction per IBC Type of Occupancy per IBC Building Use 1" Floor 713,829 0 II -B B / Fl Office, Factory 2"d Floor 295,878 4,155 II -B B Office 3id Floor 55,689 0 II -B B Office Floors thru 1. Will there be any structural work? Yes X No If yes, please describe: 2. Will there be new rack storage? Yes X.No If yes, a separate permit and plan submittal will be required. 3. Will there be a change in use? Yes If yes, please explain: 4. Existing fire protection: XSprinklers .... Automatic Fire Alarm .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes ).(No If yes, please explain: H:\Applications',Forrts-Applications On Line12016 Applicntions\Blanket Permit TI Application - 7-20 16.docx Revised: July 2016 bh Page 1 of 3 PROPERTY OWNER Name: The Boeing Company - John S. Murdoch Address: P.O. Box 3707 M/C 46-88 City/State/zip: Seattle, WA 98124-2207 CONTACT PERSON — person receiving all project communication Name: John S. Murdoch Company Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 City/State/Zip: Seattle, WA 98124-2207 Phone: (253) 740-0214 Fax: Email: john.s.murdoch@boeing.com ARCHITECT OF RECORD Name: Eric Cranston Company Name: Rolluda Architects Address: 105 S. Main St. Suite 323 City/state/zip: Seattle, WA. 98104 Phone: (206) 624-4222 Fax: Email: eric@rolludaarchitects.com GENERAL CONTRACTOR INFORMATION Name: The Boeing Company - John S. Murdoch Company Name: The Boeing Company City/State/Zip: Seattle, WA 98124-2207 Address: P.O. Box 3707 M/C 46-88 - City/State/Zip: P.O. Box 3707 M/C 46-88 Phone: (253) 740-0214 Fax: Contr Reg No.: BOEINGC*294A Exp Date: 01/18/2019 Tukwila Business License No.: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: The Boeing Company - John S. Murdoch Address: P.O. Box 3707 M/C 46-88 City/State/Zip: Seattle, WA 98124-2207 I hereby certi 'at I have < d and examined this application and know the same to be true and correct, and I am authorized under Blanket Pe ,eeme Io. BPA16-0008 to apply for and obtain this permit. Signature: g �. rtie peRG (b*Pate: 05/10/2017 doch - The Boeing Company Print Name OrganizatiDay Telephone: (253) 740-0214 Mailing WA 98124 ailing Address: City P.O. Box 3707 M/C 46-88 H:\Applications\Forma-Applications On Line\2016 Applications\Blanket Permit T1 Application - 7-2016.docx Revised: July 2016 bh State Zip Page 2 of 3 General Information 0 0 This tenant improvement application may be submitted for non-structural interior construction, which is authorized under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth in the agreement. The work is limited to that shown on the plans submitted with this application, and such work is limited to non-structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies. Mechanical Electrical City of Tukwila Building Department Plumbing / Gas Piping 206-431-3670 Rack Storage Fire Alarm Fire Sprinklers } City of Tukwila Fire Department 206-575-4404 Building Permit Application Application Submittal — Application and plans must be complete in order to be accepted for plan review. Make sure to fill out the application completely and follow the plan submittal checklist below. Handouts are available at the Permit Center which provides more in-depth detail on preparing the submittal. Authorized Agent — The applicant must be an authorized agent as identified in the Blanket Permit. Fees — The permit fees are based on valuation of construction as declared by the applicant on the application, and shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to ensure compliance with current fee schedules. To obtain a permit fee estimate, contact the Permit Center at 206-431-3670. Submittal Checklist Completed Blanket Permit Tenant Improvement Permit Application kCompleted Architects Statement X.Three (3) sets of construction drawings; which include: Site plan showing: Building location on property; Adjoining public rights-of-way; Parking layout; Location of tenant space or area of work within building; Overall dimensions of building; Overall dimensions of tenant space, or area of work; and - Name of each common wall tenant(s) and type of business or occupancy. Floor plan of entire floor or tenant space that the work is taking place, showing: Tenant space layout with use of each room labeled; All exit doors, corridors and egress patterns; All new walls, existing walls and proposed walls (provide construction key); and - All other proposed construction. Construction details Construction key; Cross sections showing wall construction and method of attachment, floor and ceiling; and - Reflected ceiling plan (if applicable). Miscellaneous 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan checker); Title block on each sheet, identifying; Project name Company job number (if applicable) Site address Blanket permit agreement number Architect, address and phone number Each sheet of plans stamped by a Washington State licensed architect; Minimum sheet size 18" x 24"; and Plans must be drawn to scale and clearly dimensioned drawings shall be prints which are clearly readable (original pencil or highlighted drawings are not acceptable). Permit Fees (plan review fee, building permit fee and state building surcharge) H:\Applications\For>ts-Applications On Line \2016 Applications\Blnnkct Permit TI Application - 7-2016.docx Revised: July 2016 bh Page 3 of 3 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Qov BLANKET PERMIT AGREEMENT - Temporary Inspection Card Plan Review No.: Blanket Permit Agreement No.: p iii `U ' 00015 Ililt 44 Otulykil,6 6 tinitAp Project Name: Site Address: Date Issued: '/ ' 10 11 CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE — 206-431-3670 "X" REQUIRED INSPECTIONS DATE APPROVED INSPECTOR INITIALS PLANS DATE DATE(S) CORRECTION NOTICE ISSUED 1. Framing 2. Insulation V 3. Suspended Ceiling $/ 4. Lath and gypsum board fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. CONTRACTOR/APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS: 1. FRAMING — After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION — After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING — Fasten diffusers, lights and seismic bracing. 4. LATH AND GYPSUM BOARD FASTENING — Prior to taping (I.B.C. Section 109.3.5 — Fire Rated Assemblies) 5. PLAN CHECK INSPECTION — Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. X Construction will not proceed past required inspections. X The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. X Construction may not deviate from that shown on the plans as submitted at time of application. X All corrections shall be made within three (3) days of notification by the Building Inspector. X No more than 30 days shall elapse between the last required inspection and the "Building Final." X Unauthorized occupancy and/or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. X The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. X The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: - Electrical City of Tukwila Building Department - 206-431-3670 Plumbing and Gas Piping City of Tukwila Building Department — 206-431-3670 - Fire Protection City of Tukwila Fire Department — 206-575-4404 - Mechanical City of Tukwila Building Department — 206-431-3670 Rack Storage City of Tukwila Building Department — 206-431-3670 THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. H:Wpplications\Forms-Applications On Line\201 I Applications\Blanket Permit Inspection Card - 10-2011.docx Created: 12-2008 Revised: 10-2011 C City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 I Phone: 206-431-3670 Fax: 206-431-3665 Web site: hap://www.TukwilaWA.gov BLANKET PERMIT AGREEMENT —Architects Statement Plan Review No.: 911- 0114 Blanket Permit Agreement No.: BPA16-0008 Project Name: 9-101 Secure Space 22J2 Site Address: 9725 East Marginal Way So. Tukwila, WA. 98108 Is any part of the work proposed under this application include ❑ Yes ® No structural work or affect structural components of the building? If yes, has the structural work been authorized by the Tukwila ❑ Yes ❑ No Building Official to be included in this application? Does the proposed work comply with the requirements of Yes ❑ No the International Building Code (2015 Edition) Chapter 10, Means of Egress? If no, please explain: Will any special inspections be required per Chapter 17 11 Yes VI No in the International Building Code (2015 Edition)? . If yes, list specific inspections: As a result of this proposal, does the parking meet the Yes ❑ No requirements of the Tukwila Zoning Code? - If no, please explain deficiency: ARCHITECT/ENG 1 ER Signature Print Name: Eric Cranston (2e6)) organization: Rolluda Architects Phone: ) 624-4222 Mailing Address: 105 S. Main St. Suite 323 Seattle WA 98104 City State Zip H: ApplicationsWorms-Applications On Line 12016 Applicationn\Blanket Permit Architect Statement - 7-2016.docx Created: 12.2008 Revised: 7-2016 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I PermitTRAK QUANTITY PAID $5,998.69 D17-0124 Address: 9725 E MARGINAL WAY 5 BLDG 9-101 Apn: 0003400018 $5,998.69 Credit Card Fee $174.72 Credit Card Fee R000.369.908.00.00 0.00 $174.72 DEVELOPMENT $5,652.81 PERMIT FEE R000.322.100.00.00 0.00 $3,423.22 PLAN CHECK FEE R000.345.830.00.00 0.00 $2,225.09 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $171.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11459 R000.322.900.04.00 0.00 $171.16 $5,998.69 Date Paid: Wednesday, May 10, 2017 Paid By: JOHN S MURDOCH Pay Method: CREDIT CARD 024692 Printed: Wednesday, May 10, 2017 2:01 PM 1 of 1 CLWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 t17-0124 Project: $OE/IX6- 7-101-2 Type of Inspection: Address: 1726" E Ati16-0/N_ it)> .5 Date Called: Special Instructions: & ONG- q -1a/ 2 p Date Wanted: 7 -24 -Il ..m. Requester: BILL Phone No: aate -6 4 -7. i8 Approved per applicable codes. Corrections required prior to approval. COMMENTS: a 3AyL FV1-1444•(6� Damipiy(-- 144-1-6- Inspector: f-Z Inspector: Date: 9-17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Be 'IYG- - 9 /D'7 -2 Type of Inspection: i i/6 - Address: g7z6 .(, AMA'efi4/4L talY Date Called: Special Instructions: _ ?? -kJ __ ,'t�l'�a T Date Wanted: 6 -.29"17 p.m. Requester:_ 10/Lr:~ Phone No: . t'2,4'6.-.--5-10.< '_ 3st J ,c7Z> t ofjfjy_ _ 1 Approved per applicable codes. t_J Corrections required prior to approval. COMMENTS: Oi< -f191/%4 I N. 6- ezui 77 NG--rA/ (}P(A✓ C7.iC. P/4/ -574/G -- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 612_4 - PERMIT NUMBERS CITY OF TUKWILA FIRE. DEPARTMENT 206-575-4407 Project:Z2-5-2- 5ecure Sprinklers: Type of Inspection: Hood & Duct: Monitor: Address: Suite #: gee (moo, 9i_ /(% v / Contact Person: filt Special Instructions: / Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: --- l'0 0 /0,i/fie- L i''_ GFi VZ--- z-% _/L:' _ t%"/ 0-1-7: pLt.ikvc..) 0 0 a C-- v ii r - p,,- ' it- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Elm 7.--'` Date: 7-j / i - Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit a�--—I00 )11-017.LP PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 97KM\ i n / O Type of Inspection: vQr- Address: Suite #..\.) Contact Person: Special Instructions: • i Phone No.: Approved per applicable codes. f' TCorrections required prior to approval. COMMENTS:• ._ Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 0 ..,,d e6(.... rel /tel f, b,4,-, .. Z ¢-rdl,/ ("0 / "tali .2� ("---Re4 -/U a/v ctrl ._ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: M4 7 Date: 7/0 7 // / Hrs.: (- 0 I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 12/1/2017 City of Tukwila Department of Community Development JOHN S MURDOCH PO BOX 3707 MC 46-88 SEATTLE, WA 98124 RE: Permit No. D17-0124 BOEING #9-101 9725 E MARGINAL WAY S 9-101 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/23/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/23/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, kfin Rachelle ' ipley Permit Technician File No: D17-0124 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 OPERMIT COORD COPYC PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0124 DATE: 05/12/17 PROJECT NAME: BOEING #9-101-2 SITE ADDRESS: 9725 E MARGINAL WAY S BLDG 9-101 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Y.c g Ault 51-13%47 Building Division Public Works A fkuic S'k;``-1 Fire Prevention Structural Planning Division ❑ Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 05/16/17 Structural Review Required DATE: CI APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: legV S J .c:4- ` 1j 11" CI 06/13/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 BOEING COMPANY, THE Home. Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries 0 Search L&I Page 1 of 9 A -Z Index Help My L841 Workplace Rights Trades & Licensing BOEING COMPANY, THE Owner or tradesperson LOHR, MICHAEL Principals LOHR, MICHAEL, SECRETARY MCNERNEY, W (JAMES), PRESIDENT (End: 01/13/2017) WOLTER, CHRISTOPHER, TREASURER (End: 01/16/2015) READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) WA UBI No. 178 005 030 100 N RIVERSIDE M/C 5003-4027 CHICAGO, IL 60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BOEINC*294ML Effective — expiration 07/13/1971— 01/18/2019 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 5/24/2017 BOEING COMPANY, THE Bond FEDERAL INS CO Bond account no. 81312466 $12,000.00 Received by L&I Effective date 01/14/2002 01/01/2002 Expiration date Until Canceled Insurance .............................. Ace American Insurance Company Policy no. HDOG27854990 $1,000,000.00 Received by L&I Effective date 10/05/2016 10/01/2016 Expiration date 10/01/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Taxdebts _................ No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .................................. No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 700,216-00 Doing business as BOEING COMPANY THE Estimated workers reported N/A L&I account representative (360)902-4817 Track this contractor Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/21/2017 Inspection no. 317944148 Location 737 Logan Ave. N. Renton, WA 98055 Inspection results date 03/14/2017 Inspection no. 317943931 Location 3003 W Casino Rd Everett, WA 98203 Violations Violations Page 2 of 9 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 5/24/2017 \ICI\ITY \AAP PROJECT SITE FROM DOWNTOWN SEATTLE ❑D 900 rn 99 EXIT 158 Q %//%iii; EXIT 157 EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT 599 TUKWILA DEVELOPVE\TAL CE\TH FROM KENT & AUBURN NO SCALE 900 SCOPE OF W0� RECONFIGURATION OF EXISTING OFFICE AREA TO SECURE SPACE OFFICE AREA. WORK INCLUDES CONSTRUCTION OF SMALL OFFICE, SERVER ROOM, LARGE MEETING ROOM, AND SECURE SMALL MEETING ROOM, ALONG WITH OPEN OFFICE. MODIFICATIONS TO HVAC, FIRE SPRINKLERS AND POWER/DATA AS REQUIRED BY RECONFIGURATION. ALL NEW PARTITIONS ARE NON—BEARING. BOEING WORKPLACE SERVICES BUILDING 09-101 SECURE SPACE 22J2 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AHA MAP 3UILDI\G ADD -SS: 9725 EAST IVAGI\AL WAY SCUTH TU<WILA, WASHI\GTO\ 9-78 0 9-35 9-52 —85 o /—\ 09-101 3UILDI\G LOCATION NO SCALE GE\E SAL \OYES A CONSTRUCTION SET OF DOCUMENTS, REVIEWED STAMPED BY THE CITY OF TUKWILA BUILDING DEPARTMENT MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS . SHOWN ON THE DRAWINGS WITHIN THE AREA OF WORK BEFORE COMMENCING ANY WORK AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. THE CONTRACTOR SHALL BRING DISCREPANCIES ON THE DRAWINGS OR SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY ONLY IF THEY REQUIRE DESIGN REVISIONS. 2. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH—IN REQUIREMENTS FOR MATERIALS OR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 3. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED OR WILL BE REMOVED PRIOR TO THE BEGINNING OF THE WORK FOR THIS PROJECT. A COPY OF THE REPORT OF THE SURVEY WILL BE FURNISHED TO THE CONTRACTOR AT THE TIME OF BIDDING OR NEGOTIATIONS. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DISCOVERED OR DAMAGED THAT IS REQUIRED. TO BE REMOVED TO SUPPORT THE WORK OF THIS PROJECT. 4. THE GENERAL CONTRACTOR SHALL OBTAIN AND MAINTAIN A FULL SET OF CONSTRUCTION DOCUMENTS ON SITE. THIS SET SHALL BE MARKED UP (RED—LINED) DAILY WITH ANY ACTUAL WORK OR INSTALLATIONS DIFFERING FROM THE CONSTRUCTION DOCUMENTS. SAID SET SHALL BE TURNED OVER TO THE BOEING CONSTRUCTION PROJECT MANAGER AT THE COMPLETION OF THE WORK FOR INCORPORATION INTO BOEING RECORD DOCUMENTS. DESIG\ TEAV OWNER: gi.._.Eremrco CONTACTOR AND STATE NO. ARCHITECT MECHANICAL ELECTRICAL BOEING DEVELOPMENT CENTER P.O. BOX 3707 M/C 46-88 SEATTLE, WA 98124 PROJECT CONTACT JOHN MURDOCH 253-740-0214 THE BOEING COMPANY BOEINC* 294ML (01.18.2018) ROLLUDA ARCHITECTS 105 SOUTH MAIN STREET, SUITE 323 SEATTLE, WASHINGTON 98104 ERIC_,+CRANSTON 624-4222 SI CONSULTING ENGINEERS 506 SECOND AVENUE, SUITE 700 SEATTLE, WASHINGTON 98104 CHRIS HALLOCK (206) 622-3321 CASNE ENGINEERING 10604 NE 38TH PLACE, SUITE 205 KIRKLAND, WASHINGTON 98033 STEVEN GARRLII (425) 522-1000 CODE SU VMAY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT TUNNEL FIRST FLOOR MEZZANINE SECOND FLOOR BUILDING GROSS AFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC DESIGN CATEGORY: WIND EXPOSURE: TUKWILA 2015 I.B.C. CODES AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE II—B, NON—COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 1,116,306 (UNLIMITED PER IBC 507.3) 713,829 50,910 713,829 55,689 295,878 1,116,306 EXISTING OFFICE AREA OF APPROXIMATELY 4,155 SQ. FT. GROUP B OCCUPANCY 111 FT. MAXIMUM 2 OVERALL (NO CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT D C SEPARATE PERMIT REQUIRED FOR: rra/yechantcai lii'pectricat WP�umbing (Wbae Piping City of Tukwila BUILDING DIVISION REVISIONS No ahs n es shall be made to the scope wnrk without prior approval of 'i~f et^tita Building Division. !ovtii'Ia will require a new pian submittal field y ihtude additional plan review fees. REVIEWED FOR COMPLIANCE WITH MAY 1-3 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 10 2017 PERMIT CENTER ISSUE FOR PERMIT 05.07.17 ING DIVISION CITY OF TUKWILA BLANKET PERMIT NO. BPA 16-0008 D1Z-4 PROJECT TITLE: 9-101 SECURE SPACE.22J2 SYM A REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE B 09-101 BETrERMENTS(WP-1 ENTRY & CANOPY DCA -9-05013 RECORD DRAWING DCA -9-05013 9-101.1 ADC HVAC UPGRADE 21406—W01969369 DLR GROUP DLR GROUP RAI/AF LS LM/LS 12.19.05 12.19.08 10.25.13 C RECORD DRAWING SECURE SPACE 21406—W01969369 33090-12 RAI/AF C/ROLLUDA AJC 11.20.14 05.07.17 Q,�BOE/N STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ROLLUDA ARCH DATE 11.20.14 CH CKED SUBTITLE COVER SHEET CURRENT REVISION SYMBOL 33090-12 C DATE 05.07.17 ENCINEER CHECKED APPROVED APPROVED TITLE SECURE SPACE BUILDING 09-101 ARCHITECTURAL MASTER DEV. CENTER, WA SHEET GO JOB NO. 33090-12 COMP NO. DWG NO. 09-101—GO � D'AWI\G I\DEX SHEET NO. SHEET NAME REVISION ARCHITECTURAL r 09 -101 -GO COVER SHEET C 09-101—G1 SYMBOLS, ABBREVIATIONS & GENERAL NOTES — 09-101-2A01 SECOND FLOOR EXITING PLAN F 09-101-2Al2R PARTIAL FLOOR PLAN — REMOVAL D 09-101-2Al2 PARTIAL FLOOR PLAN D 09-101-2A282 REFLECTED CEILING PLAN A 09-101—A220 WALL SECTIONS — 09-101—A350 DOOR AND. HARDWARE SCHEDULES. B 09-101-A580 MISCELLANEOUS DETAILS - NOT INCLUDED IN PERMIT SUBMITTAL DRAWING SETS MECHANICAL 09-101—M1 D SCHEDULES — 09 -101 -2M -12R HVAC DUCTING — REMOVAL J 09-101-2M262R FIRE PROTECTION PLAN — REMOVAL E 09-101-2M12 HVAC DUCTING J 09-101-2M62 HVAC PIPING — SECOND FLOOR PLAN D 09-101-2M262 FIRE PROTECTION PLAN E 09-101—M323 SEQUENCE OF OPERATIONS & I/O POINTS FAN COIL — 09-101—M635 DETAILS — ELECTRICAL 09-101—E1 ELECTRICAL SYMBOLS AND LEGEND A 09-101-2E7CR DATA OUTLETS — REMOVAL C 09-101-2E12R PLAN — LIGHTING — REMOVAL J 09-101-2E62R 208Y/120V POWER PLAN — REMOVAL Y 09-101—E500R LIGHTING CONTROL DIAGRAM — REMOVAL — 09-101-2E7C DATA OUTLETS C 09-101-2E12 PLAN — LIGHTING J 09-101-2E62 208Y/120V POWER PLAN Y 09-101—E500 LIGHTING CONTROL DIAGRAM — 09-101—E505 LIGHTING CONTROL DIAGRAM — 1�rt Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize ' •.� _ ' a violation of ado r ad code or ordnance. � Hence. Receipt ? approved E=' i A,'. p �, .. on. ition . is a no wleda�®d: e, Q/_ Dat -�!zot rT-1, City of Tukwila .1 it 1 getl REVIEWED FOR COMPLIANCE WITH MAY 1-3 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 10 2017 PERMIT CENTER ISSUE FOR PERMIT 05.07.17 ING DIVISION CITY OF TUKWILA BLANKET PERMIT NO. BPA 16-0008 D1Z-4 PROJECT TITLE: 9-101 SECURE SPACE.22J2 SYM A REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE B 09-101 BETrERMENTS(WP-1 ENTRY & CANOPY DCA -9-05013 RECORD DRAWING DCA -9-05013 9-101.1 ADC HVAC UPGRADE 21406—W01969369 DLR GROUP DLR GROUP RAI/AF LS LM/LS 12.19.05 12.19.08 10.25.13 C RECORD DRAWING SECURE SPACE 21406—W01969369 33090-12 RAI/AF C/ROLLUDA AJC 11.20.14 05.07.17 Q,�BOE/N STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ROLLUDA ARCH DATE 11.20.14 CH CKED SUBTITLE COVER SHEET CURRENT REVISION SYMBOL 33090-12 C DATE 05.07.17 ENCINEER CHECKED APPROVED APPROVED TITLE SECURE SPACE BUILDING 09-101 ARCHITECTURAL MASTER DEV. CENTER, WA SHEET GO JOB NO. 33090-12 COMP NO. DWG NO. 09-101—GO � r c c c c 2 C LEGE\D/SYM3OLS AB3EVIATIO\S GE\ ERAS \OTES SECTION LETTER is! CEILING MOUNTED OCCUPANCY SENSOR OR DETAIL NUMBER DESIGNATION / e \, . A $Das SWITCH, OS INDICATES INTEGRAL OCCUPANCY SENSOR, D INDICATES BUILDING, WALL SECTIONS INTEGRAL DIMMER & AND JT JOINT AT 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF TUKWILA PRIOR TO COMMENCING CONSTRUCTION. X # X # AND DETAIL REFERENCES 0 INTERCOM/SPEAKER 15A, 120V DUPLEX RECEPTACLE AB ANCHOR BOLTK ACP ACOUSTICAL CEILING PANEL KO KNOCK OUT ACT ACOUSTICAL CEILING TILE 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S) ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET NUMBER WHERE DETAILED 20 20A, 120V, DUPLEX RECEPTACLE FOURPLEX ADX ADJACENT L LENGTH AFF ABOVE FINISHED FLOOR LB LAG BOLT SHEET IS IN THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. — A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SHEET NUMBER REFERENCED FROM -----� I REFERENCE TO DETAIL/ENLARGED PLAN 15A, 120V, RECEPTACLE xx �o FIRE ALARM HORN/STROBE, xx INDICATES CANDELA RATING AGC AGGREGATE LEN LENGTH AL ALUMINUM LF LINEAL FEET LL LIVE LOAD SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA #X # /Oh X # I�__ `'> DETAIL DESIGNATION �� 0 DATA/TELEPHONE OUTLET FIRE SPRINKLER HEAD ROOF/ACCESS HATCH ALT ALTERNATE ALUM ALUMINUM LWR LOWER ANCH ANCHOR, ANCHORAGE MATL MATERIAL APA AMERICAN PLYWOOD ASSOC. MAXIMUM DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON MAX APPD APPROVED DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR NM, Ants SHEET NUMBER WHERE DETAILED CO (IF SAME AS SHEET REFERENCED FROM) SECTION/DETAIL DESIGNATION TOILET URINAL APPROX APPROXIMATE MB MBR MACHINE BOLT MEMBER AS1M AMERICAN SOCIETY OF MTLMFR TESTING MATERIALS METALMANUFA BTWN BETWEEN MIN MINIMUM MISCELLANEOUS () TO SUBMITTING ANY REQUESTS FOR INFORMATION RFIs . 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. XXXXX XXXXX 0 LAVATORY BLDG BUILDING MISC 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. SHEET NUMBER WHERE DETAILED BLKG BLOCKING MO MASONRY OPENING MT MOUNT(ED) (ING) 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, SHEET NUMBER REFERENCED FROM I o MOP SINK BOT BOTTOM MTL METAL UNLESS OTHERWISE NOTED. C CHANNEL DF DRINKING FOUNTAIN . CB CATCH BASIN N NORTH(COORDINATE) 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. NORTH ARROW CC CENTER TO CENTER NF NEAR FACE 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. ELEVATION DATUM = = SANITARY NAPKIN/TAMPON DISPENSER CEM CEMENT NIC NOT IN CONTRACT CF CUBIC FEET NO. NUMBER CJ CONTROL JOINT NOM NOMINAL CL CENTER LINE NTS NOT TO SCALE 12. PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. OR SPOT ELEVATION ElPAPER TOWEL DISPENSER/DISPOSAL CLG CEILING CLR CLEARANCE) OA 0/C ONE CENTER 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH—IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS ( �'_X■� CEILING HEIGHT A.F.F. COL COLUMN OD OUTSIDE DIAMETER PROJECT. XXXXXX ROOM NAME__ DOUBLE ROLL TOILET PAPER DISPENSER HANDICAP GRAB BAR, 1 1/2"O.D. COMP COMPRESSED) (ION) CNC CONCRETE OF OUTSIDE FACE COIN CONNECTION OFCI OWNER FURNISHED CONTRACTOR INSTALLED 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. XXXX CONST CONSTRUCTION OPG .OPENING 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED ROOM NUMBER MATERIALS BE PARTS THIS PROJECT AND MATERIALS TO STAGED BY BOEING BE LOCATED. o TOILET SEAT COVER DISPENSER CONT CONTINUOUS, CONTINUE OPP OPPOSITE, OPPOSITE HAND CCONTRACT(OR) TO REUSED IN LATER OF WHERE BE ARE TO ® DOOR NUMBER CTT CERAMIC TILE PAR PARALLEL 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL %°%RW%``%``%°.``��``% EARTH, DIRT, UNDISTURBED CTSK COUNTERSUNK PCC PRECAST CONCRETE PARTITION/WALL TYPE CY CUBIC YARD(S) PCF POUNDS PER CUBIC FOOT 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND ��—TTII I © H=L—IIIT Ti%—T�fT EARTH, DIRT, COMPACTED PERF PERFORATE(D) REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, IN MATERIAL OR 0, DIA DIAMETER PERIM PERIMETER DB_ DOUBLE PL PLATE CHANGE SIMILAR. 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. INTERIOR ELEVATION :OX.'SIC■ STONE, GRAVEL, POROUS FILL DEIAOL DEMOLISH, DEMOLITION PLAM PLASTIC LAMINATE DEP DEPRESSED PLYWD PLYWOOD XXX (WHERE SPACE IS LIMITED) DIA DIAMETER PNL PANEL 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS W ��4, BRICK, COMMON DIAG DIAGONAL PREST PRESTRESS(ED) INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. REVISION CLOUD WITH20. "BEAK" DIM DIMENSION PRF PREFORMED DL DEAD LOAD PSF POUNDS, PER SQUARE FOOT PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS REVISION LETTER > CERAMIC TILE DN DOWN PSI POUNDS PER SQUARE INCH AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. DS DOWNSPOUT PT POINT, PAINT DWG DRAWING PVC POLYVINYL CHLORIDE 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS. • ' . •' • • ..... • •. • •. • 7' • '• • . • '• CONCRETE . E EAST (COORDINATE) R RADIUS (CURVATURE) EA EACH R RISER 22. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT VCT CPT FLOOR MAT'L TRANSITION ViitiiliiiliiiiiiRInIii INSULATION: BATT, LOOSE FILL, BLANKET EB EXPANSION BOLT RB RESILIENT BASE METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF • EF EACH FACE REF REFERENCE, REFER TO REINF REINFORCE(D) (ING) STRUCTURE ABOVE, U.N.O. 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS EJ EXPANSION JOINT ...._.........., INSULATION: RIGID BY THEIR ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION ,,,,,� FLOOR RECESS .....................<. EL ELEVATIONREQ REQUIRE(D)(INC)EQUIRED ( ) ELEV ELEVATION REV REVISION(S), REVISED WORK. BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. ^ % i ALUMINUM EQ EQUAL RH RIGHT HAND END WALL GUARD EW EACH WAY RO ROUGH OPENING EXIST EXISTING 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFELY CODES, REGUALTIONS AND BOEING REQUIREMENTS. CORNER GUARD PM!.0.09. 7/,A,/.A: BRASS, BRONZE, COPPER EXP EXPOSED S SOUTH (COORDINATE) EXT EXTERIOR SECT SECTION SF SQUARE FEET 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN COMPLIANCE W/ALL r�//j/ METAL, STEEL, IRON FAS FASTEN(ER) SHT SHEET APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. ( CPT -1) FINISH DESIGNATION FF FINISHED CEILING SIM SIMILAR 26. PORTIONS OF THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE ALL WORK TO AVOID AS MUCH AS — GRID/GRID BUBBLE AND f . = :-•f, -: :- PLASTER: SAND, CEMENT, GROUT FF FACTORY FINISH SQ SQUARE POSSIBLE ANY INCONVENIENCE TO BUILDING OCCUPANTS AND PROVIDE FOR THEIR SAFETY, ACCESS AND EGRESS THROUGHOUT THE PROJECT WORK. THE CENTERLINE FF FINISHED FLOOR SST, SS STAINLESS STEEL FOR FINISH GRADE ST STRUCTURAL TEE CONTRACTOR SHALL FULLY SCREEN OFF AREAS UNDER CONSTRUCTION BY TEMPORARY SCREENS OR PARTITIONS AS NECESSARY TO LIMIT DUST, DIRT, NOISE, FUMES OR OBJECTIONABLE ODORS FROM ENTERING OCCUPIED AREAS. •• •' ' ' • • -' • ' PLASTER: GYPSUM WALL BOARD FH FIRE HYDRANT STD STANDARD --- --- --- -- CONSTRUCTION ABOVE OR BELOW, BEYOND OR BEHIND (HIDDEN) � FIN FINISH(ED) STL STEEL FND FOUNDATION STR • � % ) ) WOOD: FINISH FOC FACE OF CONCRETE SYM SYMMETRY SYMMETRICAL CONSTRUCTION "FLAG" NOTE FOR SPECIFIC CONSTRUCTION DIRECTIVE FOF FACE OF FINISH SYS SYSTEM WOOD: ROUGH CONTINUOUS FDIC FURNISHED BY OWNER/ T&B TOP AND BOTTOM GENERAL "BOAT" NOTE FOR INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE [ T SPECIFIC OR EXISTING HISTORICAL FO FINISHED OPENING TEMP TEMPORARY INFORMATION. WOOD: INTERRUPTED BLOCKING FRD FOR REFERENCE ONLY THICK(NESS) A WINDOW TYPE FT FOOT THK TOC TOP OF CURB FTC FOOTING TOC TOP OF CONCRETE II II A FUT FUTURE TOL .11 PLYWOOD: SMALL SCALE TOLERANCE _ _ ® HANDRAILS, KICK PLATES AND OTHER FIELD VERIFY TOS TOP OF STEEL FV F REVIEWED FOR PHYSICAL PROTECTION TS STRUCTURAL TUBE CRFG GLASS FIBER REINFORCED GYPSUM COMPLIANCE WITH FOO- TYP TYPICAL 2d--67 FEC FIRE EXTINGUISHER FIRE EXTINGUISHER & CABINET > PLYWOOD: LARGE SCALE GALV GALVANIZED GC GENERAL CONTRACTOR UBC UNIFORM BUILDING CODE U .o MAY /).,..5 2017 � i ������������ UL UNDERWRITERS' LABEL SUPPLY AIR DIFFUSER WALL TYPE: CONCRETE MASONRY (CMU) GI GALVANIZED IRON /0\ UNO UNLESS NOTED OTHERWISE GR GRADE UPR UPPER MI RETURN AIR GRILLE GT GROUT (ivy of•Tukw la FLOURESCENT LIGHT FIXTURE \/"/\/. WALL TYPE: STEEL STUD GNB GYPSUM WALL BOARD VB VAPOR BARRIER :. ,I ,: �� BUILDING DIVISION 1 ( VINYL COMP. TILE (PENDANT MOUNTED)VC HCNR HARDENER VERT VERTICAL HCWD HARDWOOD JAM 2.3 2f1a LIGHT FIXTURE �� VIF VERIFY IN FIELD g I ,--FLOURESCENT WALL TYPE: WOOD STUD (PENDANT MOUNTED) HDWR HARDWARE W WEST (COORDINATE) HG HIGH GRADE .V ' RECEIVED CITY OF TUKWILA FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT W WIDE FLANGE LIGHT (NL) CIRCUIT WALL TYPE: EXISTING HN HOLLOW METAL W . WIDTH, WIDE MAY 1 0 2017 O RECESSED OR PENDANT LIGHTING FIXTURE o RECESSED OR PENDANT LIGHTING FIXTURE — — o FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT — — WALL TYPE: REMOVAL LIGHT (NL) CIRCUIT HORZ HORIZONTAL WC WATER CLOSET HS HIGH STRENGTH WD WOOD HT HEIGHT W/ WITH W/O WITHOUT IBC INTERNATIONAL BLDG. CODE WWF WELDED WIRE FABRIC '"`i:-i�■r:'.:L .J -r��.� • .yam M N PERMIT CENTER ID INSIDE DIAMETER„ NL ° L, cS I WALL SCONCE 1 � INSIDE DIMENSION �� �`' �� � °��• ��� . 3 8 S WALL TYPE: PARTITION T-0" HIGH � WALL SCONCE 2 ( ® EXIT SIGN (CEILING UNIT) ID NOTE: REFER TO THE COLOR AND MATERIAL IF INSIDE FACE SCHEDULE FOR ADDITIONAL FINISH AND IN INCH DESIGNATIONS/ABBREVIATIONS INCL INCLUDED(D) �`���� y ro r rP �� rj �� � � e � I ISSUE FOR PERMIT 05.07.17 I-0 EXIT SIGN (WALL MOUNT) II II WALL TYPE: GLASS (ING) T SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ® M.t E 71 : Nr ACCEPTABILITY DESIGoR SPECIFICATION rISAAPPROVED DRAWN DLR GROUP DATE 07.10.07 SUBTITLE ABBREVIATIONS & SYMBOLS LEGEND CURRENT REVISION 33090-12 _ SYMBOLTHIS DATE 05.07.17 LTPCKED 07.10.07 s' GIS RED ARCHI CT STATE OF WASHINGTON — SECURE SPACE 33090-12 EC/ROLLUDA 05.07.17 SHEET 1 ENGINEER TITLE SECURE SPACEG BUILDING 09— ARCHITECTURAL MASTER 1 0 1 D.C. APPROVED BY DEPT. DATE CHECKED 1 i I i 1 i a a . , t JOB NO. 33090-12 COMP NO. APPROVED DWG No. 09-101-G1 APPROVED r c c c c 2 C REVISION 0' TRAVEL DISTANCE EXIT WIDTH 36' 204' DISTANCE EXIT WID 72' ::::::::i l �J I I II I %i r/���'/i. //,. i.' r /iii/i%iL >%%i" //j / %/' / i/ % /a iiiii //i 'r/ // "'„ �'/.;r- sa,�/""//A / / / // / // /i ,/ I I I•I•I•I I %/r/%%%%/ 44 /'//;/•"77 'iii//'//' i� ■11■■ 11■11■■0 e: 6 ■■■=■■■••1111••' a 11.111111M1=11=== ■■■11••■■r■ -�� I. --11M11111111111111111111111 ■■�■■u■u�■■■n■■■�■■�� , •■u■111111111 �■■11MM11■■11u�■■■u■■■�I = 1111■■■■11■■=1 �■■■�11■1111111111.11■1111I■1111■1=■■ ASI / = ■■■■■■11■■1111111 u■■■=■■11••11■r■■■■1111■■111N■■MINIII...' £ ,I / �■■■■111111■IM1 M■■■�■■1111111111�■■■■■■■11�■t X11 i11■■■1111■11I1 �■■11M■■■■■1111=■■■■■■■■�■• �L_. :��■■■11■11 1 u■■■u■■■■■■■u■■■■■■■.... �� __ ■111111■■M1u■■11=111111■■■■1•■■1111■■■■u■■ r■�_ I MMMMM MINI 11•111111111111MMIIINIMIIIIIIIIIMEMIN•MINIIIINIINfl •11111L911111II C111C1111111�111I1111C1��� ■1111111111 ■\11111111 NE' �•U ••iiiii�U•UUUii�ii �� >`.11 1 miumummumumuumumiwil j� 1111111111111111 I will■1111111`11111111■1� >•mi1L ISE .111111111111111 Mill �111C1111111�1: .1111_1. __111.1_. rr ://7/..%// / ii' 9 LEGEND: EXIT WAYS EXIT ACCESS GENERAL NOTES: CONSTRUCTION NOTES: 11111111111111111111 11111/11 11111tl■■1111111t1t1111 ■■■■■■■■■1111■1111■■■■NIIIk-/■■11ME■11111111■■u■1111 ■11111111M11\_1•M=1111■■11111111111111111111111■■■■■■■■■■111 ■■■■■■■■■■1111■■■■■111111111l-M■'■■1111■■■11■11111111111111 11111■■1.1111111■ �111111111111111111MIEN=■■■■■■■■■1111111 L11111111111111111�i��111�1111111�11i IIIII■1I m•11111mu111111111111i 1111■■■■■■■■■1111■■■■■SII u■■■■■■■■■■■■■■■■■u■r��■■■■�r�■■■■■■■■■■■■1 1iii■u■M■iiiiii •11111.Mi: _��1111•i �� ■■■■■■■■■■■III —_---o_•F�\i11'?� \■�■■•111111111111IIII1\\■111 • G111111111■■u■■■1111■■■111 1. WA IF% r4i g // , 4 ,i iii4„0„, ii%%% j -®14- l'immilimimmilhmun Il111111111111iiiimiii■IlliElliNIMEIREalin IIIIIIIIIIIIIIIIUIIIIIII ■■ ,: I■■i■■1111111111111111■■■■■�■■■111111 %; ; IIIIHOIIIIHHIHIIHIO I 11111111111111111111MI1i��,• 41;;;;;;;;;;;;;;;;;;;;;;;iii ■ IIli' Ii 11111 ■.,.--��N ►� JA; 2:0 2010 REVIEWED FOIA COMPLIANCE WITH ?-04-St- MAY - S- MAY )--3 2017 City of Tukwila BUILDING DIVISION T J I v amp RECEIVED CITY OF TUKWILA MAY 1 0 2017 PERMIT CENTER 50' 15' 0 15' 30' 60' SCALE: 1” = 30' ISSUE FOR PERMIT 05.07.17 F-22 WORK ROOM RECORD DRAWING MOONSHINE SHOP RELOCATION — PHASE 2 SECURE SPACE W1208311 W1208311 20671-10 33090-12 BY DLR GROUP DLR GROUP EISI EC/ROLLUDA APPROVED RJV RJV GMM DATE 06.29.12 SYM REVISION BY APPROVED DATE 6604 10.19.12 12.31.13 H 05.07.17 J F22 OFFICE AS—BUILT WHITE AREA F22 INSTALL DOOR SWIPES J#781375—LO J#180243-00 HANSON M.DITTMER MRM 03.26.98 06.22.98 02.05.99 EZN o'- REG .TER ARC C ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPOVED BY STATE OF WASHINGTON DEPT. DATE DRAWN G.MILLER CHECKED DATE 10.29.97 SUBTITLE SECOND FLOOR EXITING PLAN CURRENT REVISION 33090-12 SYMBOL V DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 9-101 COL. A -Z/1-20 SHEET 2A01 JOB NO. 33090-12 COMP NO. DEV. CENTER, WA DWG No. 9-101-2A01 SYM STAIR C 21Ja1 LEGEND: INNS EXITWAY EXISTING PARTITION OR PERMANENT WALL NO CHANGES. NEW PARTITION WAINSCOT WALL FINISH, SEE E/A564 FOR MATERIALS, PAINT WALL ABOVE, TIP. PAINT CORRIDOR WALLS ,CG CORNER GUARD, SEE s/A562 NOTE: SEE SHT 2A13 FOR THE ONE REQ'D EXIT FOR THIS AREA. GE\PAL \OTES 22Ja1 STO RAG E 21 M2 14'-8" OFFICE 22M2 HALLWAY 21Ja2 EXIT ( 24M2 NOTE THE OCCP. LOAD ON THIS HALLWAY IS 6 TOTAL FOR EXITING 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK AND STAGING AREAS CLEAN AND UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS AND MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. 6. ALL WALL DIMENSIONS TO FACE FINISHED SURFACE, UNLESS NOTED OTHERWISE. 7. ALL NEW STUD WALL TO RECEIVE 3" ACOUSTICAL BATT INSULATION U.N.O. 8. FRAME AROUND ALL EXISTING DUCTS, PIPES, UTILITIES, ECT. AS REQUIRED. VOVAL \OTES ROBOT OFFICE 21M3 NOTE ONLY ONE REQ'D. ) EXIT FOR THIS AREA 23 1 REMOVE EXISTING DOOR, FRAME AND HARDWARE. PATCH AND REPAIR WALL FINISHES AS REQUIRED BY REMOVAL. DISPOSE OF MATERIALS. REMOVE EXISTING DEMOUNTABLE PARTITION. PATCH AND REPAIR ADJACENT FINISHES AS REQUIRED. REMOVE PORTION OF EXISTING FRAME WALL FOR NEW DOOR. REMOVE 5'-0"W X 7'-0"H PORTION OF EXISTING WALL FOR NEW OPENING. REMOVE EXISTING DOOR, FRAME AND HARDWARE AND DISPOSE OF MATERIALS. PATCH AND REPAIR SLAB AS REQUIRED FOR NEW FLOORING. AT AREA SHOWN HATCHED. SEE DETAIL 5/A580. 5 REVISION A BR&T TEST BED INFILL DOOR OPENING CAFETERIA - RECORD DRAWING SECURE SPACE 12254733 33090-12 EXITING ROUTES EXIT MI 1101111 • • 0 REMOVE UNICAN LOCK AT EXTERIOR DOOR. PROVIDE AND INSTALL VON DUPRIN BLANK ESCUTCHEON PLATE. —REVIEWED FOR COMPLIANCE WITH 04) 2A11 MAY 3-5 2017 2A20 City of Tukwila BUILDING DIVISION 2A22 2A23 2A24 2A25 2A26 2A27 0 2A28 2A29 2A30 2A32 ti 4 2A33 0 • REMOVAL 12320 .KEY P_AN RECEIVED CITY OF TUKWILA CALE: NONE ISSUE FOR PERMIT 05.07.17 MAY 0 2017 16' BY TWH TWH HDG APPROVED TWH TWH LC DATE 07.21.09 11.03.10 10.31.13 05.07.17 SYM REVISION CONSOLIDATE ATS LAB CONSOLIDATE ATS LAB (30" WAS 48") BY MRM MRM APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED 07.15.99 07.30.99 ERIC CRANSTON STATE OF WASHINGTON DRAWN C.ROSE CHECKED J .BARN ES ENGINEER L.BROWN CHECKED J.ANDERSON APPROVED APPROVED P.WOLD SUBTITLE FLOOR PLAN - MO 3309 12 05.07.17 TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 COL. J—N/1-6 2Al2R JOB NO. 33090-12 WWM DEV. CENTER, WA DWG ND. STAIR C 21Ja1 PRIVACY ROOM BUSINESS OCC. 167 SF®100 GROSS 2 OCCUPANTS PER TABLE 1004.1.2 LEGEND: EXISTING PARTITION OR PERMANENT WALL NO CHANGES. NEW PARTITION WAINSCOT WALL FINISH, SEE E/A564 FOR MATERIALS, PAINT WALL ABOVE, TYP. PAINT CORRIDOR WALLS EX IT -WAY ELECTRICAL ROOM BUSINESS OCC. 145 SF©100 GROSS 2 OCCUPANTS PER TABLE 1004.1.2 • OPEN •:OFFICE. • BUSINESS OCG. 2,386SFb100GROSS • • • 24. OCCUPANTS PER .TAKE• 1004:1.2• NOTE: SEE DETAIL A/A220 FOR DETAILS TYPICAL AT SECURE WALL (SCIF) CONSTRUCTION. NOTE: SEE SHT 2A13 FOR THE ONE REQ'D EXIT FOR THIS AREA. EQUIPMENT STORAGE GROUP S2 OCCP AREA= 620 SF OCCP. LOAD 2 MAX. QA RECORDS GROUP B OCCP AREA= 775 SF OCCP. LOAD 8 NOTE: VISUALLY INSPECT AREA PERIMETER WALLS ABOVE AND BELOW CEILING. AT LARGER OPENINGS, FRAME OPENING AND MATCH EXISTING WALL CONSTRUCTION. AT SMALLER OPENINGS, PROVIDE INSULATION AT OPENING AND FULLY CAULK EACH SIDE OF WALL WHERE OPENING OCCURS. SEE PENETRATION DETAIL C/A220 AT TYPICAL CONDITIONS. STORAGE OFFICE : MEETING, .ROOM. •.. • • :BUSINESS, OCC.('A' USE) ...1,037 SF®15..GROSS• . • • ...70 OCCUPANTS • .:PER TALE ..1.00 .1...2.•. • CO\STUCTIO\ \OTES (co\T') PROVIDE AND INSTALL NEW 3'-0" X 7'-0" STC 51 DOOR AND FRAME. SEE SHEET A350. OFFICE BUSINESS OCC. 134 SF®100 GROSS 2 OCCUPANTS PER TABLE 1004.1.2 2Al2 A220 SIM. EXIT 24M2 HALLWAY NOTE THE OCCP. LOAD ON THIS HALLWAY IS 6 TOTAL FOR EXITING PROVIDE AND INSTALL NEW DEMOUNTABLE PARTITIONS IN LAYOUT SHOWN. SEE DETAILS D/A580 AND E/A580. PROVIDE FULL DEPTH ROXUL AFB INSULATION FRICTION FIT TO STUD SPACE. PREP AND PAINT. COLOR TBD. 10 WHERE UNICAN HAS BEEN REMOVED AT DOOR EXTERIOR, INSTALL VON DUPRIN 99 SERIES BLANK ESCUTCHEON PLATE. CORNER GUARD, SEE S/A562 GE\EAL \OTES 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK AND STAGING AREAS CLEAN AND UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS AND MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. 6. ALL WALL DIMENSIONS TO FACE FINISHED SURFACE, UNLESS NOTED OTHERWISE. 7. ALL NEW STUD WALL TO RECEIVE 3" ACOUSTICAL BATT INSULATION U.N.O. 8. FRAME AROUND ALL EXISTING DUCTS PIPES, UTILITIES, ROBOT PROVIDE AND INSTALL NEW CARPET AND RUBBER BASE AT AREA SHOWN HATCHED. OFFICE BUSINESS OCC. 123SF®100 GROSS 2 OCCUPANTS PER TABLE 1004.1.2 OFFICE BUSINESS OCC. 145SF®100 GROSS 2 OCCUPANTS PER TABLE 1004.1.2 OFFICE NOTE ONLY ONE REQ'D. (NI EXIT FOR THIS AREA RESEARCH WORK ROOM GROUP B OCCP AREA= 2,292 SF OCCP. LOAD 23 MAX. LEES CARPET EMERGING LIGHTS II 'GALACTIC' #898 24" X 24" TILE ALL WALLS TO RECEIVE RUBBER BASE. BURKE-MERCER 'BLACK' 4 1/2" COVE BASE PROVIDE 5/8" TYPE 'X' GWB AT NEW FRAMED 5'-0"W X 7'-0"H OPENING. PREP AND PAINT TO MATCH EXISTING FINISHES AT EXTERIOR SIDE. INTERIOR COLOR TO BE DETERMINED. PROVIDE CORNER GUARD AT JAMB. CORNER GUARD INFO HERE. EXI'I 23L1 2Al2 A456 PROVIDE AND INSTALL NEW VCT AT AREA SHOWN HATCHED. OPEN OFFICE AREA NO CHANGES TO LOADING OR SQUARE FOOTAGES EXITING ROUTES ARMSTRONG STANDARD EXCELON IMPERIAL #51836 CLASSIC SHELTER WHITE 12" X 12" X 1/8" ALL WALLS TO RECEIVE RUBBER BASE. BURKE-MERCER 'BLACK' 4 1/2" COVE BASE CO\STUCTIO\ \OTES CONSTRUCT NEW FRAME WALL FROM FLOOR TO 6" ABOVE CEILING. SEE SECTION A/A220. 3 5/8" X 18 GA. STEEL STUDS AT 16" O.C. (2) LAYERS 5/8" TYPE 'X GWB EACH SIDE. 3" ROXUL AFB INSULATION FRICTION FIT TO STUD SPACE. PREP AND PAINT. COLOR TBD. CONSTRUCT NEW FRAME WALL PER SECTION B/A220. 3 5/8" X 18 GA. STEEL STUDS AT 16" O.C. (2) LAYER 5/8" TYPE 'X GWB EACH SIDE. 3" ROXUL AFB INSULATION FRICTION FIT TO STUD SPACE. PREP AND PAINT. COLOR TBD. INFILL OPENING AT WALL WHERE DOOR HAS BEEN REMOVED. MATCH EXISTING WALL CONSTRUCTION. PROVIDE 3" ROXUL AFB INSULATION FRICTION FIT TO STUD SPACE. PREP AND PAINT. COLOR TBD. INFILL HOLE AT EXISTING WALL. MATCH EXISTING WALL CONSTRUCTION. PREP AND PAINT. COLOR TBD. PROVIDE AND INSTALL NEW 3'-0" X 7'-0" WOOD DOOR IN HM FRAME. SEE SHEET A350. PROVIDE NEW 3'-0" X 7'-0" WOOD DOOR IN ALUM. FRAME AT NEW DEMOUNTABLE WALL. SEE SHEET A350. PROVIDE AND INSTALL NEW 3'-0" X 7'-0" STC 45 DOOR AND FRAME. SEE SHEET A350. PROVIDE (1) LAYER 5/8" TYPE 'X' GWB AT EXISTING WALL FROM FLOOR TO 9'-6" A.F.F. PREP AND PAINT. COLOR TBD. O'd G00 1v REMOVE UNICAN KNOB LOCKSET AT CATWALK DOOR AND REPLACE WITH UNICAN LEVER SET. COORDINATE WORK WITH BOEING LOCK AND KEY. PROVIDE AND INSTALL WALL MOUNTED CELL PHONE . REVlEJ EDFO 2A 6 LOCKERS. (50)LOCKERS TOTAL. SURFACE MOUNTE .COMPLI' CE W Thi SALSBURY 19100 SERIES, ALUMINUM FINISH r� S �C 2A22 #WBB1888346 (GLOBALINDUSTRIAL.COM) MAY �- 2017 CONSTRUCT NEW FRAME WALL PER SECTION B/A222J -- 3 5/8" X 18 GA. STEEL STUDS AT 16" O.C. S City of (1) LAYER 5/8" TYPE 'X GWB EACH SIDE. BUILD! PREP AND PAINT. COLOR TBD. PARTIAL S ECO \ D FLOG PLA\ SCALE: 1/8"= 1'-O" 66 ukwila DIVISION 2A31 fltj 2A21 2A27 2A33 RECEIVED CITY OF TUKWILA MAY 10 2017 K EY P LA\ SCALE: NONE ISSUE FOR PERMIT 05.07.17 OERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A BR&T TEST BED W09293505 TWH TWH 07.21.09 B C INFILL DOOR OPENING W011194884 CAFETERIA — RECORD DRAWING 12254733 TWH HDG TWH 11.03.10 LC 10.31.13 D SECURE SPACE 33090-12 E.C/ROLLUDA 05.07.17 QMEir,MG c'- REI STE'` D AR a. ITEI1` ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY C CSTON STATE OF WASHINGTON DRAWN C.ROSE -CHECKED J.BARNES ENCINEER L.BROWN SUBTITLE SYMBOL FLOOR PLAN 05.07.17 TITLE CHECKED J.ANDERSON APPROVED G.CULTUM APPROVED P.WOLD SECURE SPACE BUILDING 09-101 COL. J -N/1-6 ARCHITECTURAL MASTER JOB NO. 33090-12 COMP NO. DEV. CENTER, WA DWG NO. 09-101-2Al2 1/0 (v) K IEX ITWAYH{) I OFFICE 22M2 • 0 • N/N • ALLWAY 23M2 NL ONE REQ' seiT S AREA ✓ V 0 0 2 V • EXITING ROUTES r • 0 Lt ®_ 0 2 l u 1 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied; illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. Vestibules at level of discharge, 5. Exterior landings and areas used for exit discharge. REVIEWED FOR COMPLIANCE WITH a-pfL MAY 3 2017 City f Tukwila BUILDING DIVISIO"'1�i PARTIAL DEFLECTED CEILI\G PLA\ SCALE: 1/8"= 1'-0" C6 " LEGE\I —0 2' X 4' LIGHT FIXTURE 2' X 4' EMERGENCY LIGHT FIXTURE LIGHTED 'EXIT' SIGN HVAC DIFFUSER GRILLE CE\RAL \ETES 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK AND STAGING AREAS CLEAN AND UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS AND MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. CO\ STRUCTIC \OTES REMOVE AND REPLACE EXISTING GRID AND TILES. COODINATE WITH MECHANICAL AND ELECTRICAL. SEE SHEET A580. GRID: USG DONN DX, WHITE TILE: ARMSTRONG FISSURED #755 24" X 48" X 5/8" SQUARE EDGE, WHITE PROVIDE AND INSTALL NEW GWB CEILING. SEE SHEET A220. 0• ©Om ISSUE FOR PERMIT 05.07.17 8' 4' 0 4' 8' 20 16' SCALE: 1 /8"=1'-0" RECEIVED CITY OF TUKWILA MAY 102017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAFETERIA — RECORD DRAWING SECURE SPACE 12254733 33090-12 HDG C/ROLLUDP LC 10.31.13 05.07.12 Q� BOE/A/G° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ROVED BY DEPT. DATE DRAWN DATE CREECKED SUBTITLE REFLECTED CEILING PLAN CURRENT REVISION SYMBOL n 33090-12 A DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE SECURE SPACE BUILDING 09-101 ARCHITECTURAL MASTER COL. J—N/1-6 DEV. CENTER, WA SHEET 2A282 JOB NO. 33090-12 COMP NO. DWG NO. 09-101-2A282 2A280 2A281 /2A282/ 2A283 2A284 2A285 2A286 2A287 2A288 2A289 2A290 2A291 2A292 2A293 2A294 2A295 2A296 2A297 I 2A298 2A299 2A300 2A301 2A302 2A303 IAr4 P. MC ISSUE FOR PERMIT 05.07.17 8' 4' 0 4' 8' 20 16' SCALE: 1 /8"=1'-0" RECEIVED CITY OF TUKWILA MAY 102017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAFETERIA — RECORD DRAWING SECURE SPACE 12254733 33090-12 HDG C/ROLLUDP LC 10.31.13 05.07.12 Q� BOE/A/G° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ROVED BY DEPT. DATE DRAWN DATE CREECKED SUBTITLE REFLECTED CEILING PLAN CURRENT REVISION SYMBOL n 33090-12 A DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE SECURE SPACE BUILDING 09-101 ARCHITECTURAL MASTER COL. J—N/1-6 DEV. CENTER, WA SHEET 2A282 JOB NO. 33090-12 COMP NO. DWG NO. 09-101-2A282 S?Sl Sl S?Sl Sl Sl Sl 1 \AN 3 1/2" FIBERGLASS BATT INSULATION — 3'-0" TO EITHER SIDE OF WALL 2 SMcMlCA Sl N 0 LAY—IN CEILING 3 5/8" X 18 GA. STEEL STUDS AT 16" 0.C. (2) LAYERS 5/8" TYPE 'X' GWB EACH SIDE 3" ROXUL AFB ACOUSTIC INSULATION RUBBER BASE NOTE: PAINT WALLS FULL HEIGHT OF WALL AT WALLS: GA FILE NO. WP 1524 WALL SECTIO\ SCALE: 1" = 1'-0" 2Al2 A220 PAINT PLYWOOD DECK, LEAVING FIRE—RATING LABELS EXPOSED. 0 0) 8" X 18 GA. STEEL JOISTS AT 24" 0.C. 3/4" FIRE RATED T & G PLYWOOD SHEATHING 3 1/2" FIBERGLASS BATT INSULATION — TO 3'-0" FROM WALL CARPET 3 1/2" FIBERGLASS BATT INSULATION EXTENDING FULL WIDTH OF ROOM f (2) LAYERS 5/8" TYPE 'X' GWB ON RESILIENT FURRING CHANNELS AT 16" 0.C., PERPENDICULAR TO CEILING JOISTS. 3 5/8" X 18 GA. STEEL STUDS AT 16" 0.C. (2) LAYERS 5/8" TYPE 'X' GWB EACH SIDE 3" ROXUL AFB ACOUSTIC INSULATION RUBBER BASE NOTE: PAINT WALLS FULL HEIGHT OF WALL AT CEILING: GA FILE NO. FC 4370 AT WALLS: GA FILE NO. WP 1524 WALL SECTIO\ SCALE: 1" = 1'-0" (/TF) 2Al2 A220 (E) METAL DECK TYPICAL AT 2ND FLOOR AND ROOF BASE LAYERS 5/8" TYPE X GWB OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 3 5/8" STEEL STUDS CO 16" 0.C. WITH HORIZONTAL BRACING AT 4'-0" WITH 1" TYPE S DRYWALL SCREWS © 12" OC, DOES NOT NEED TO BE TAPED. FACE LAYER 5/8" TYPE X GWB OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 3 5/8" STEEL STUDS © 16" 0.C. WITH .WITH 1" TYPE S DRYWALL SCREWS © 12" OC, JOINTS STAGGERED 24" EACH LAYER AND SIDE. SOUND TESTED WITH FULL DEPTH "ROXUL" FIBER INSULATION FRICTION FIT IN STUD SPACE. (NLB) RESILIENT BASE (BOTH SIDES) FLOOR FINISH SEE FIN. SCHED. ALL PENETRATIONS THROUGH . SCIF WALLS SHALL BE KEPT TO A MINIMUM. INTO SCIF MORE THAN ONCE. DO NOT INSTALL PENETRATIONS FOR FUTURE ALL MATERIALS USED IN CONSTRUCTION OF THE SECURITY WALL SHALL BE OVERLAPS DESIGNED TO SCIF STANDARDS. CONTACT BOEING SECURITY FOR DOCUMENTATION OF THE MEANS AND METHODS OF CONSTRUCTION BEFORE STC 55-59 GA FILE No. WP 1524 FOR SOUND RATING ONLY SCIF WALL DETAILS ACOUSTICAL INSULATION IN FLOOR DECK CAVITY ABOVE TOP TRACK COPE GWB TO DECK ABOVE WITH 1/2" BEAD ACOUSTIC SEALANT METAL DEFLECTION TRACK (1 1/2" SLOTS TO ALLOW 3/4" MOVEMENT UP AND DOWN) FULL DEPTH OF ROXUL ACOUSTICAL FIRE BATT INSULATION PIPE OR CONDUIT ACOUSTICAL CAULKING — CONTINUOUS FULL DEPTH OF GWB, EACH LAYER FULL CIRCUMFERENCE, BOTH SIDES ALL WIRE OR CABLE UTILITIES (POWER, SIGNAL, TELEPHONE, NETWORK, ETC) MUST BE SURFACE MOUNTED RETAINER ANGLE WITH ACOUSTICAL CAULKING — CONTINUOUS FULL WIDTH AND HEIGHT, BOTH SIDES (TIP) DUCT DUCT ACOUSTICAL SOUND LINER BASE RUNNER TRACK SET IN ACOUSTICAL CAULKING CONTINUOUS FULL LENGTH TO CONCRETE SLAB ACOUSTICAL CAULKING — CONTINUOUS FULL DEPTH OF GWB, EACH LAYER, BOTH SIDES (E) CONC. SLAB UTILITIES SHOULD NOT CROSS WALL USE. DOCUMENTED, EDGES SEALED AND VISUAL AND PHOTOGRAPHIC CLOSING ANY SCIF WALL. c SCALE: NONE JAM as MD ISSUE FOR PERMIT 05.07.17 2A11520 REVIEWED FOR COMPLIANCE WITH jS 4Q� MAY 2._75 2017 City of T'uIjta BUILDING DIVISION RVED CITY OF TUKWILA MAY 10 2017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE SECURE SPACE 33090-12 C/ROLLUDA 05.07.17 gLEszmrBO IS :' ED HLT ERIC RAN 0 STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR ICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EC/ROLLUDA CHECKED ENGINEER CHECKED DATE 04.04.17 SUBTITLE WALL SECTIONS CURRENT REVISION SYMBOL 33090-12 DATE 05.07.17 APPROVED APPROVED TITLE SECURE SPACE BUILDING 04-021 ARCHITECTURAL MASTER COL. X—X/X-X RENTON, WA SHEET A220 JOB NO. 33090-12 COMP NO. DWG NO. 09-101—A220 c r c c 1- c c SYM D 0 N SCHEDULE DOOR MARK DOOR SIZE TYPE MATL FINISH RATING FRAME MAIL FRAME FINISH HDW GROUP DETAILS NOTES HEAD JAMB SILL WALL SECOND FLOOR WALL BASE WALL MATL HEIGHT RAMP —FACTORY FINISH SECOND FLOOR ACOORDIAN PARTITION 201 J14 3'-0" X 7'-0" A — — — — — 1 — — — REVISE HDWRE/EXIST. DOOR 201 K14 3'-0" X 7'-0" A HM PNT — STL PNT 2 G/A500 G/A500 11/A500 50-52 STC RATING 2'X4' ACOUSTIC PANELS —EXISTING 201J15 3'-0" X 7-0" A WD STAIN — STL PNT 4 FAC FAC FAC VESTIBULE 202J15 3'-0" X 7'-0" A WD STAIN — STL PNT 4 FAC FAC FAC 202J15 203J15 28'-9" X10'-0" B FAB FAC — STL PNT B-1 13/A500 — — FROM 7.251 BLDG. 201K15 13'-6" X10'-0" B FAB FAC — STL PNT 13/A500 — — TO MATCH 203J15 202K15 3'-0" X 7'-0" A WD STAIN — STL PNT 5 4/A500 4/A500 4/A500 203K15 3'-0" X 7'-0" A WD STAIN — STL PNT 5 4/A500 4/A500 4/A500 201J16 3'-0" X 7'-0" A WD STAIN — STL PNT 4 FAC FAC FAC 202J16 49'-0" X10'-0" B FAB FAC — STL PNT B-1 13/A500 — — FROM 7.251 BLDG. 201K16 3'-0" X 7'-0" A WD STAIN — STL PNT 5 4/A500 4/A500 9/A500 i 202K16 3'-0" X 7'-0" A — — — — — — — — EXIST. DOOR 21Ja1 3'-0" X 7'-0" A MTL PNT — HM PNT — EXISTING EXTERIOR DOOR 22Ja1 3'-0" X 7'-0" A WD STAIN — ALUM FAC 5 21Ja2 3'-0" X 7'-0" A WD STAIN — ALUM FAC 8 22Ja2 3'-0" X 7'-0" A WD STAIN — ALUM FAC 5 21K1 3'-0" X 7'-0" A MTL. PNT — HM PNT 6 STC 45 ACOUSTIC DOOR 22K1 3'-0" X 7'-0" A WD STAIN — HM PNT 7 21K2 3'-0" X 7'-0" A MTL. PNT 60 HM PNT 8 STC 51 ACOUSTIC DOOR CW1Ja2 3'-0" X 7'-0" A MTL. PNT — HM PNT — EXISTING DOOR — UNICAN KNOB TO UNICAN LEVER D 0 0 TYPES SCALE: 1/8"=1'-0" A B FLUSH ACCORDIAN REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REVISED HARDWARE RBB SC/BM 06.08.95 B SECURE SPACE 33090-12 EC/ROLLUDP 05.07.17 BOE/NG C'- 1 STER® ITEC E`IC CRANSTON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED )ift.0000.0.AIDPROVED BY DEPT. DATE DRAWN DATE CFFIECKED REVIEWED F0 COMPLIANCE_ WITH MAY). -32011 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA MAY 102017 PERMIT CENTER ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONSTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. HAS �WA�E GOUPS: HARDWARE GROUP #1 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #2 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE 1 CLOSER NORTON 7500L HARDWARE GROUP #3 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D, W/ KEY LOCK 1 CLOSER NORTON 7500L HARDWARE GROUP #4 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LATCHSET YALE 5401L, 497, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #5 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET YALE 5407, 497, US26D 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 HARDWARE GROUP #6 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET SARGENT AND GREENLEAF — 2890 X 542 (500 SERIES, TYPE IV) 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 NOTE: PROVIDE 14GA JAMBS AND 18GA HEADER AT SOUND DOORS. HARDWARE GROUP #7 1 EXIT DEVICE 1 CLOSER 1 ACOUSTICAL SEAL PEM KO YAMS MO HARDWARE GROUP #8 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE NORTON 7500L 1 CLOSER 1 ACOUSTICAL SEAL PEMKO, 332AR NOTE: P (VIDE 14GA J. BS NDHEADER AT SOUND DOORS. SUBTITLE DOOR AND ROOM FINISH SCHE ' LE 33090-12 SYMB 3 DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 DEV. CENTER, WA SHEET A350 JOB NO. 33090-12 COMP NO. DWG NO. 09-101—A350 00N P\SH SCHEDULE ROOM NUMBER ROOM NAME FLOOR NORTH EAST SOUTH WEST CEILING NOTES BASE WALL BASE WALL BASE WALL BASE WALL MATL HEIGHT RAMP —FACTORY FINISH SECOND FLOOR ACOORDIAN PARTITION 201J14 MULTI—PURPOSE F-1/2/3 B-1 W-1 B-1 W-1 B-1 W-1/3 B-1 W-1 C-1 11'-0" EXIST. CEILING MATERIAL B-1 NEW 4" RESILIENT BASE C-1 2'X4' ACOUSTIC PANELS —EXISTING 201J15 VESTIBULE F-2 B-1 W-2 B-1 W-2 B-1 W-2 B-1 W-1 C-1 11'-0" EXIST. CEILING 202J15 MULTI—PURPOSE F-1/2 B-1 W-1/3 B-1 W-1 B-1 W-2/3 B-1 W-1/2 C-1 11'-0" EXIST. CEILING 201J16 MULTI—PURPOSE F-1 /2 B-1 W-2/3 B-1 W-1 B-1 W-1 B-1 W-1/2 C-1 11'-0" EXIST. CEILING BOE/NG C'- 1 STER® ITEC E`IC CRANSTON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED )ift.0000.0.AIDPROVED BY DEPT. DATE DRAWN DATE CFFIECKED REVIEWED F0 COMPLIANCE_ WITH MAY). -32011 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA MAY 102017 PERMIT CENTER ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONSTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. HAS �WA�E GOUPS: HARDWARE GROUP #1 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #2 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE 1 CLOSER NORTON 7500L HARDWARE GROUP #3 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D, W/ KEY LOCK 1 CLOSER NORTON 7500L HARDWARE GROUP #4 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LATCHSET YALE 5401L, 497, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #5 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET YALE 5407, 497, US26D 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 HARDWARE GROUP #6 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET SARGENT AND GREENLEAF — 2890 X 542 (500 SERIES, TYPE IV) 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 NOTE: PROVIDE 14GA JAMBS AND 18GA HEADER AT SOUND DOORS. HARDWARE GROUP #7 1 EXIT DEVICE 1 CLOSER 1 ACOUSTICAL SEAL PEM KO YAMS MO HARDWARE GROUP #8 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE NORTON 7500L 1 CLOSER 1 ACOUSTICAL SEAL PEMKO, 332AR NOTE: P (VIDE 14GA J. BS NDHEADER AT SOUND DOORS. SUBTITLE DOOR AND ROOM FINISH SCHE ' LE 33090-12 SYMB 3 DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 DEV. CENTER, WA SHEET A350 JOB NO. 33090-12 COMP NO. DWG NO. 09-101—A350 COV1 FINISH SCHEDULE LEGE\J FLOORS WALLS KEY MATERIAL KEY MATERIAL F—i CARPET ON RAISED FLOOR W-1 GYPSUM WALLBOARD — PAINT — NEW AND EXISTING WALLS F-2 EXISTING CONCRETE W-2 VANGUARD WALL F-3 RAMP —FACTORY FINISH W-3 ACOORDIAN PARTITION BASE CEILINGS KEY MATERIAL KEY MATERIAL B-1 NEW 4" RESILIENT BASE C-1 2'X4' ACOUSTIC PANELS —EXISTING BOE/NG C'- 1 STER® ITEC E`IC CRANSTON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED )ift.0000.0.AIDPROVED BY DEPT. DATE DRAWN DATE CFFIECKED REVIEWED F0 COMPLIANCE_ WITH MAY). -32011 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA MAY 102017 PERMIT CENTER ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONSTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. HAS �WA�E GOUPS: HARDWARE GROUP #1 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #2 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE 1 CLOSER NORTON 7500L HARDWARE GROUP #3 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 EXIT DEVICE VON DUPRIN 99L—F, SIZE 3, 299 STRIKE, US26D, W/ KEY LOCK 1 CLOSER NORTON 7500L HARDWARE GROUP #4 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LATCHSET YALE 5401L, 497, US26D 1 CLOSER NORTON 7500L HARDWARE GROUP #5 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET YALE 5407, 497, US26D 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 HARDWARE GROUP #6 1 1/2 PR. HINGES STANLEY FBB 179, 4 1/2' X 4 1/2" NRP, US26D 1 LOCKSET SARGENT AND GREENLEAF — 2890 X 542 (500 SERIES, TYPE IV) 1 CLOSER NORTON 7500L 1 ACOUSTICAL SEAL PEMKO, 332AR 1 WALL STOP TRIMCO 1270 WX X 630 NOTE: PROVIDE 14GA JAMBS AND 18GA HEADER AT SOUND DOORS. HARDWARE GROUP #7 1 EXIT DEVICE 1 CLOSER 1 ACOUSTICAL SEAL PEM KO YAMS MO HARDWARE GROUP #8 1 EXIT DEVICE VON DUPRIN 99E0 -F, SIZE 3, 299 STRIKE, US26D, W/ BLANK FACE NORTON 7500L 1 CLOSER 1 ACOUSTICAL SEAL PEMKO, 332AR NOTE: P (VIDE 14GA J. BS NDHEADER AT SOUND DOORS. SUBTITLE DOOR AND ROOM FINISH SCHE ' LE 33090-12 SYMB 3 DATE 05.07.17 ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 DEV. CENTER, WA SHEET A350 JOB NO. 33090-12 COMP NO. DWG NO. 09-101—A350 SYM REVISION 12 GA. VERTICAL HANGER WIRE 45° S 45 W LOCATE VERTICAL COMPRESSION POSTS PER DETAIL 2A282 A580 AT 12'-0" O.C. EACH WAY, LOCATED 4'-0" MAX. FROM PERIMETER WALL ATTACH TO STRUCTURE ABOVE PER DETAIL 2A282 A580 USE #12 GA. SPLAY WIRE BRACING IN PLANE OF EACH TEE. VERTICAL ANGLE, 45°. MINIMUM 3 TIGHT TURNS AT EACH END. NO BENDS OR KINKS ON WIRES. CROSS TEE 45 MAIN TEE NOTE: HANGER WIRES "E" AND "W" ARE IN THE SAME VERTICAL PLANE AS THE MAIN TEE. HANGER WIRES "N" AND "S" ARE IN VERTICAL PLANES PERPENDICULAR TO THE MAIN TEE. SEISMIC CEILI G�I� �EST/6\1 \G \T E SCALE: NO SCALE C #12 GA. HANGER WIRE, TYP. 3 TURNS, MINIMUM 8" MAX. PROVIDE CLEARANCE AT OPPOSITE WALLS, (NOT ATTACHED). ATTACHED AT STARTING AND ONE ADJACENT WALL =1L1\S G�I� AT WALL -SECTIO\ (TYP) SCALE: NONE DE V OU\TA 3OTTON WALL 2A282�A580 2"WIDEx2"LONG x12 GA. STRAP 2A282 580 WALL AS SCHEDULED, TYP DEMOUNTABLE PARTITION BOTTOM TRACK, TYP ITW/BUILDEX - 12-24x1 1/4" HWH TRAXX/5 FASTENER AT 2'-0" ON CENTER, TYP BASE AS SCHEDULED, TYP RAISED COMPUTER FLOORING AND/OR CARPET, TYP 3LE PATITIO\ - SECTIO\ (TYP) SCALE: 3"= 1'-0" BY APPROVED DATE SYM (/75' 2Al2 A580 REVISION O 0 0 O 0 0 O 0 0 0 o o 0 0 o 0 0 o o 0 0 } O 0 O 0 #12 PERIMETER WIRE HANGERS 8" MAX FROM WALL - TYP FOR MAIN AND CROSS RUNNERS #12 WIRE HANGERS 1548" O.C. E.W. SUSPEND FROM STRUCTURE ABOVE CEILING BRACING ©12'-0" O.C. E.W. START AT LESS THAN 6 FEET FROM WALL OMIT WHERE ROOM IS 144 SF OR LESS. SEE 1/A535. TYPICAL 3AC1\G LAYOUT (2 SCALE: NO SCALE 2"WIDEx2"LONG x12 GA. STRAP HA\GES SCALE: 3"=1 -0" 2A282 A580 1/4" DIAMETER POWDER ACTUATED FASTENER WITH WASHER, 1/2" MIN. EMBEDMENT, TYP 12 GA. HANGER, SLACK AND/OR SPLAY WIRE, TYP 3 FULL TURNS EACH END 1/4" DIAMETER POWDER ACTUATED FASTENER WITH WASHER, 1/2" MIN. EMBEDMENT, TYP 12 GA. SLACK AND/OR SPLAY WIRE, TYP 3 FULL TURNS EACH END WISE -SECTIO\ (TYP) n 45° MAX SUSPENDED � CEILING DEMOUNTABLE PARTITION ID 3 EIVOU CACI\ SCALE: NONE BY 2A282 A580 FOR ATTACHMENT TO METAL DECK ABOVE SEE DETAIL A580 A580 #12 GAUGE WIRE, PARTITION SEISMIC BRACE, ONE FOUR -WIRE SPLAY BRACE AT EVERY 8 LINEAR FEET MINIMUM 3 TIGHT TURNS AT EACH END NO BENDS OR KINKS ON WIRES \TA3LE PATTITIO\ G SECTIO\ (TYP) APPROVED DATE SECURE SPACE 33090-12 C/ROLLUDA 05.07.17 2Al2 A580 Q� BOE/NG o'— 7/8" CHANNEL MOLDING 2" BEAM AND RETAINING CLIP (BERC2) PER MFR #12 HANGER WIRE TEE GRID SYSTEM PER MFR DECREASE HANGING WIRE SPACING TO 42" ON CENTER © LOCATION OF TILES WITH GYP BACKING, TYPICAL TYP. ACT SEISV IC ATTACH. SCALE: N.T.S. ST AUT - SECTIO\ 2A282 A580 1/4" DIAMETER POWDER ACTUATED FASTENER WITH WASHER, 1/2" MIN. EMBEDMENT, TYP COMPRESSION POST SCALE: 3"= 1'-0" (TYP 1 7/8" 3 3/8" EXISTING SECTION VIEW I u 1 A282 A580 EXISTING 2ND FLOOR SLAB WITH HOLE (TYP.) CONCRETE SLAB NO. 9 GA. FIXTURE SUPPORT WIRES AT CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR. 6�,:v1AX. CROSS TIE OVERBORE HOLE (4"0 X 3/8" DEPTH) AND CATCH ALL DEBRIS AT UNDERSIDE OF FLOOR TO PREVENT HAZARDOUS ISSUE WHILE GRINDING. CONTRACTOR SHALL SUBMIT PRODUCT INFO TO BOEING FOR APPROVAL. .4 •• a 4 4 • d PROPOSED SECTION VIEW CONCRETE SLAB PROVIDE ACOUSTIC FOAM FILL AT HOLE HOLE PLUG DETAIL AT SLA3 RECESSED FLUORESCENT FIXTURE MAIN STRUCTURAL RUNNER 4'-0" O.C. LIGHT FIXTURE 3V\CE -DETAIL (TYP) SCALE: NONE 45° NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3" OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EA. CONNECTION POINT. 2A282 A580 3/8" X 3 7/8"0 STEEL PLATE 3 16 1/4"0 X 6" LONG FLAT HEAD MACHINE SCREW W/1/4"0 NYLON LOCK NUT SCALE: N.T.S. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY ERIC STON STATE OF WASHINGTON DEPT. DATE DRAWN C -T Ei CKED DATE ISSUE FOR PERMIT 05.07.17 SUBTITLE REVIEWED FOR COMPLIANCE WITH 6" AT City of Tukwila BUILDING DIVISION 2Al2R A580 RECEIVED CITY OF TUKWILA MAY 1 o 2017 PERMIT CENTER CEILING DETAILS ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 COL. N.A. DWV. CENTER, WA SHEET OL A580 DATE 05.07.17 JOB NO. 33090-12 COMP NO. DWG NO. 09-101-A580 r C r • C