Loading...
HomeMy WebLinkAboutPermit D17-0131 - LENSCRAFTERS - REMODEL IN MACY'S STORELENSCRAFTERS 500 SOUTHCENTER MALL D17-0131 Parcel No: Address: 0 City of Tukwila O Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3597000246 500 SOUTHCENTER MALL Project Name: LENSCRAFTERS Permit Number: D17-0131 Issue Date: -1 9- 111 Permit Expires On: 11/18/2b17 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: FEDERATED DEPT STORES INC 7 W 7TH ST ATTN: TAX DEPARTMENT - SHF, CINCINNATI, MN, 45202 TIM SCHENK 1120 E 80 ST #211, BLOOMINGTON, MN, 55420 OAKSTONE CONSTRUCTION INC 4065 YOSEMITE PL, PLACERVILLE, CA, 95667 OAKSTCI988KC ELDER JONES INC 1120 E 80TH ST , BLOOMINGTON, MN, 55420 Phone: (952) 345-6040 Phone: (530) 642-8858 Expiration Date: 5/24/2018 DESCRIPTION OF WORK: REMODEL TO A SMALL PORTION OF THE EXISTING MACY'S DEPARTMENT STORE TO CREATE A LENSCRAFTER VISION CENTER DEPARTMENT Project Valuation: $85,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $2,352.66 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: CI C Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 1 f. I hearby certify that I have read and examined this permit and know th.esame to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per;�f�a d a•,:' o cond• • ns attached to this permit. Signature. />' g Date:/a Print Name:.�i/�//�� /// This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 10: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit hardware. (IFC 1008.1.10) 14: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 12: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 11: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 15: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 17: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: . These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 22: ***BUILDING PERMIT CONDITIONS*** 23: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 24: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 25: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 26: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 27: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 28: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 29: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 30: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 31: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 32: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 33: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.TukwilaWA.gov fl Building Permit No. 7- 013I Project No. ^ � Date Application Accepted: t `f 7 Date Application Expires: , I -f‘&--17 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 'Soo 50Jf4C.EMt"TL (r1At1- Suite Number: Floor: AfeirMItl' Tenant Name: LCARLaZS PROPERTY OWNER Name: T(M 5Gt4br4R Name: MAC(5 Conft riArESE7LYle,ES City:6laflt «rOrf State: ,y1N Zip: ss't{ZO Address: -7 wen.- SEYeivrl 4 5rneur Email: 41neus e elder c,nes .con....... City:61 reci (b14.1'( State: 014 Zip:4 Z CONTACT PERSON — person receiving all project communication Name: T(M 5Gt4br4R Address: I%24 E . 8a M. sr. stiir Zai City:6laflt «rOrf State: ,y1N Zip: ss't{ZO Phone:4152..345.6040 Fax q st .9S4.. 4gQrj Email: 41neus e elder c,nes .con....... GENERAL CONTRACTOR INFORMATION Company Name: T'Q .12 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: HAAppliodionsWorna-Applications On Line\2011 ApplicationsU'ermit Application Revised - 8-9-I l.docx Revised: August 2011 bh New Tenant: ® Yes 0 ..No ARCHITECT OF RECORD Company Name: MAYO W a 141106 1€4 Am. . Architect Name: M411.1eio 0. vit4IAMgZ Address: i2 CapiAANJ c.141 City:st m 5 134 aii State: cx Zip Phones Z(46. 14424 Fax: EmA:w ritmer a ownezera diesiox mu.. V ENGINEER OF RECORD Name: 41.0... b6 4°4- - 1/0//6.5 Company Name: tAtcwt.E L mune-5 9,E City: 4 /.40Tod State: tete/ Zip: /✓4 Engineer Name: rnl cbilzeLamyleS . Address: zditAt (AG iriff 9Q I O E 6 L. L City: 54 AIM► oes State: w) Zip 11? Phone:1,LQ AAS .9331 Fax: Email: MONS eo MWCASd<<(ilQA1S .CQrti... LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 41.0... b6 4°4- - 1/0//6.5 Address: (/z -o 6..,,,.07- irO 7a.I 07 City: 4 /.40Tod State: tete/ Zip: /✓4 Page 1 of 4 BUILDING PERMIT INFORMATIO - 06-431-3670 A Valuation of Project (contractor's bid price): $ ILTSP33— Describe the scope of work (please provide detailed information): ftermoEL Th a smarm. RiaflcW 134E EN(tsnr(G OeiltlarnIerrscartZ It1 C (IEAM A LErtscR silts vino" cer11 h1- Oefisakivevr Existing Building Valuation: $ Will there be new rack storage? ❑ Yes Qr.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: eictsnNG IV nem A.'v, [✓f Sprinklers fir Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms-Applications On Line12011 ApplicationslPermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I st Floor I 2nd Floor 3'd Floor Floors thru Basement 1742o 6126 --. Q Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: eictsnNG IV nem A.'v, [✓f Sprinklers fir Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms-Applications On Line12011 ApplicationslPermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO illATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Er..Tukwila ❑... Water District #125 0 ...Water Availability Provided Sewer District Er..Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑ .. Renton ❑...Sewer Availability Provided O .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer 0 ...Cap or Remove Utilities ❑ ...Frontage improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size Geotechnical Report .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public IS It IV WO # WO # WO # Private El Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line 0 ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip HAApplicationsWorms-Applications On Line12011 Applientions\Permit Application Revised - 8-9-t l.docx Revised: August 2011 bh Page 3 of 4 0 0 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR�RIZED AGENT: Signature: Print Name: 'r (M s CAA E Date: S, Day Telephone: q s Z . 60 40 Mailing Address: ((ZQ a. to smart svav: * aoarn t4f 4lr0d , ('1d 5 5-4 7,0 City State Zip II:tApplicationsJForms-Applications On Line 12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $1,454.83 D17-0131 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $1,454.83 DEVELOPMENT $1,385.77 PERMIT FEE R000.322.100.00.00 0.00 $1,381.27 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $69.06 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11979 R000.322.900.04.00 0.00 $69.06 $1,454.83 Date Paid: Monday, July 24, 2017 Paid By: OAKSTONE CONSTRUCTION Pay Method: CHECK 23045 Printed: Monday, July 24, 2017 10:32 AM 1 of 1 CiPSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY. PermitTRAK PAID $1,071.14 D17-0131 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $897.83 DEVELOPMENT $897.83 PLAN CHECK FEE R000.345.830.00.00 I 0.00 i $897.83 EL17-0374 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $91.87 ELECTRICAL $91.87 PLAN CHECK FEE R000.345.832.00.00 I 0.00 $91.87 M17-0066 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $45.87 _ MECHANICAL $45.87 PLAN CHECK FEE R000.322.102.00.00 0.00 i. $45.87 PG17-0068 Address: 500 SOUTHCENTER MALL Apn: 3597000246 $35.57 PLUMBING : $35.57 PLAN CHECK FEE R000.322.103.00.00 0.00 _ $35.57 TOTAL FEES PAID BY RECEIPT: R11512 :, $1,071.14 t. Date Paid: Thursday, May 18, 2017 Paid By: ELDER -JONES Pay Method: CHECK 77930 Printed: Thursday, May 18, 2017 11:21 AM 1 of 1 <'rl SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: i dgCell-P1e 2 Tye of Inspection: l c.iizi Di/j6- / 4L Address: 500 A5J775e //mu Date Called: Special Instructions: Date Wanted: /3 % ? Requester:9 Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 441, Inspector: 4 Date: ?7/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit b1-7- 031 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �'poSC19-4F Type of Inspection: Si4P6iba �. 0 /L%AZ- Address: 1 SSCO-14C6). TE-. Ii L CJ Date Called: Special Instructions: Date Wanted :rte Q 13/ "7 "g' . Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: ot/g /7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 'DO -Gi3I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 19AfSCe...41-'IES Type of Inspection: �(ISP,CAJ Dal aliii 6 - Address: 0 Sain4e6orrie Date Called: Special Instructions: Date Wanted: 97/7 a.m. Requester: Phone No: ElApproved per applicable codes. ki Corrections required prior to approval. COMMENTS: f;--)ec seei,041,6e ceitifigv Date: q/7/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '11-01`31 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Prroject: � t eAA ( 1. i^..,1i' ,i Typ Inspection: A /N Address: SW 'l'&.tire MAU.. Date Called: • Special Instructions: •QQr��„ %�fl% s" Date Wante :' > % a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: g REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 17-F—/C? 17-S —/- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ZeitiCgAlcrez Sprinklers: Fire Alarm: Type of Inspection: - SPr,Li ,, r c - ff,,,i Address: Sy/71/t- #: 6W Pre -Fire: /7///// Contact Person:Suite Special Instructions: �- 5- Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: - /NShn-/ d 3 /0 ---- �- 5- _S-"feri-1-0(e r S Z2. /or fe V ke14 PlICS (9/fiv ��voi PSS - //,,A- / Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,.1--,1 3 Date: 9'//v, -7 Hrs.: / .) v I / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 8932 Southcenter — Lenscrafter's 6-15-17 2015 Washington State Energy Code Calculations b raBF- 0 13 r. REVIEWED FOR ODE COMPLIANCE APPROVED 1 JUN 2 9 2017 City of Tukwila BUILDING QLVISI_N CORRECTION LTR# RECEIVED CITY OF TUKWILA JUN 2 8 2017 PERMIT CENTER Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write- protected. Project Title: 1 - This title will copy onto other forms Date 6/15/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use Company Name: Nextore Company Address: 4000 Luxottica Place; Mason, OH 45040 Applicant Name: Michael Romes Applicant Phone: 920-445-5007 Applicant Email: mromes@nextoreretail.com Project Description ❑ New Building ❑ Addition O Alteration 0 Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions to encs. C502.2.6 for additional requirements. requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting in addition are combined with existing building systemsligsting systems to demonstrate re combined d with exce ❑ ❑ ❑ ,I ❑ Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit maybe combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. ❑ No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced ❑ ❑ ❑ Less than 50% of existing are replaced 0 ❑ ❑ Lamp and/or ballast replacement only — existing total wattage not increased ❑ ❑ i ❑ i 50% or more lighting - Total li replaced p 9 9 Power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting 0 Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) ❑ ❑ New or moved lighting panel 0 ❑ ❑ Interior space is reconfigured - luminaires unchanged or relocated only ❑ New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out at top of LGT-SUM Date 6/15/2017 Interior Lighting System Description Existing lighting to remain in Sales floor ceiling. Sales floor valance lighting and display lighting being removed. New track lighting being added to sales floor for accent lighting. New 2x2 fixtures will be added for new office area. Interior Lighting Power Allowance Method ❑ Building Area Method 0 Space -by -space Method Select method used in project. Interior Lighting Controls 0 All C405.2.1 - C405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) ❑ Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: ® 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA O C406.3 High Efficacy Lighting 0 Exterior Lighting System Description None Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 Calculation Area NO"' 0 0 Addition- 0 Addition stand alone + existing 0 Spaces where < 50% of 0 Spaces where t 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type ® Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE' 8 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 100 Sales area 11.75 635 1 .270 806 101 Health care facility: Exam/treatment 10 76 1.330 101 102 Health care facility: Exam/treatment 10 80 1.330 106 103 & 104 Health care facility: Exam/treatment 10 122 1.330 162 Lobby ArUExhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display 913 LTG -INT -DISPLAY Allowed Watts Allowance from 616 1793 Proposed Lighting Wattage NOTE 3 Location (plan #, room #) Fixture Description NOTE a, s, s Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed 100 existing 2x2 Fluor 8 84 672 101 2x2 LED's 2 39 77 102 2x2 LED's 2 39 77 103 & 104 2x2 LED's 2 39 78 Proposed Retail Disp ay Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 798 1702 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building liohtino systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 General Note - In Sales areas, an increase in lighting power allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible merchanise display lighting may be included in the Gross Interior Area under each Retail category. This lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use Location (plan #, room #) Retail Sales Area Type NOTE 1 Gross Interior Area in ft2 Allowed Watts per ft2 NOTE 2 Watts Allowed (watts/ftZ x area) 100 Retail 1: All unclassified retail display 194 0 . 60 116 Existing track in reconfigured space 2 39 78 Total Retail With Display Area Maximum 194 Total Watts Base Allowance Allowance "OTE 3 116 Retail Display Lighting Retail Display 500 616 Proposed Retail Display Lighting Wattage NOTE4 Retail Area Location (plan #, room #) Fixture Description NOTE 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Retail 1 100 TL and TL2 track heads - Size per Current Limiter 1 720 720 Retail 1 100 Existing track in reconfigured space 2 39 78 Total Retail Proposed Display Watts NOTE 7 798 RETAIL DISPLAY WATTAGE ALLOWANCE - PER LPA Proposed Retail Display Lighting Totals from LTG -INT -DISPLAY Retail Display Power Allowance NOTE 8 616 Retail 1 Retail 2 Retail 3 Retail 4 798 Note 1 - Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.2.2.1 may be entered in this table. Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11. Note 3 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 4 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 5 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 7 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG -INT -SPACE. Note 8 - Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG -INT -SPACE. Note 9 - Enter a unique title for each lobby area in project that has art/exhibit display lighting. Note 10 - Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c = 0.5 W/ft2. Note 11 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table. Note 12 - Only separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of general area lighting, may be entered in this table. Note 13 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG -INT -SPACE. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 General Note - In Lobby areas, an additional wattage allowance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting may use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allowance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NOTE 9 Lobby Description including (plan # & room #) Gross Interior Area in ft 2 Maximum Display Watts Allowed NOTE 10 Per Area Proposed Display Lighting Total NOTE 11 Per Area Total Lobby with Display Area Total Lobby Art/Exhibit Display Allowance NOTE 13 Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE 12 Lobby Area Location (plan #, room #) Fixture Description NOTE 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Total Lobby Art/Exhibit Proposed Display Watts Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG -CHK Revised August 2016 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken E200 Yes C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters E200 NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves E200 Yes C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls E200 Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; E300 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception E200 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used NA C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. NA C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Yes C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require E200 specific application lighting controls per this section Yes C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; E200 Indicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NAcontrol C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key of all installed luminaires and switched receptacles in guest room NAcontrol C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy for supplemental task lighting, includingunder-shelf or under -cabinet lighting NA C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, g g, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 NA C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% NA C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) NA C405.13 C408.3 If claiming lighting system commissioning exemption provide supporting calculation; Lighting system functional testing Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; E200 Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently NA C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy_ratinq (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yes C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable E200 NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed ig ti ., M•' • , . -- p_ .._ C , P.. 4 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 LTG -CHK Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 6/15/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electricalplans that each dwellingunit in GroupR-2 has a separate electrical energy meter NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive Yes is n._-" 2- --'- C405.10 _ - -' r- - Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; E200 - Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control uestion, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist June 16, 2017 Rachelle Ripley, Permit Technician Department of Community Development c/o City of Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 RE: LensCrafters (Inside Macy's) 500 Southcenter Mall Tukwila, WA 98188 Dear Ms. Ripley: phase zero design We have revised the CD set based upon the review comments provided to us. Below is a description of the revisions made. architecture 1. Item 1: The energy code analysis has been done on the proper forms. interior design 2. Item 2: We have provided a north arrow on the V000 -Macy's Floor Plan Basement Floor, and the A100 -Fixture Floor Plan. planning 3. Item 3: Regarding the wall types we call them out on the A101 sheet in a key that will then refer you to the A300 sheet. After further investigation, we added an additional wall type. It is wall type D, this then refers you to detail number 6 on A300. 4. Item 4: The door that opens to a wall is a previously closed off void space from Macy's. This space is not accessed through that door. G.C. is to install and supply a permanently mounted sign on the door that states, this is not an exit. There is an access panel near the entry of Macy's if one needs to access the space. 5. Item 5: Concerning the new walls being constructed that create a large concealed space, we have noted on sheets A101, that that the G.C. is to provide horizontal and vertical fire blocking @ 10' O.C. (as required by the building code 718.2.2), to the new walls surrounding the void space. No combustible materials shall be permitted within this void space as well. This is also detailed out on sheet A300, number 6. 6. Item 6: On the fixture plan, sheet A100, there are no missing existing walls along the top of the tenant space. These lines are just distinguishing the different spaces between the tenants within Macy's. We have indicated the different departments in Macy's surrounding Lenscrafters on the plan. RECEIVED Thank you for your assistance in permitting this project. If there are any further CITY OF TUKWILA questions or comments, please feel free to reach out to us. JUN 28 2017 Sincerely, David A. Farrilfgton Associate Princip Architectural Coordinator for LC/Macy's Program CORREC LTR# bU7Ot31 PERMIT CENTER Phase Zero Design, Inc. 8 Wilcox Street Simsbury, CT 06070 t 860.264.1624 f 860 264 1628 www.phasezerodesign.com June 07, 2017 City of Tukwila Department of Community Development TIM SCHENK 1120E 80 ST#211 BLOOMINGTON, MN 55420 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0131 LENSCRAFTERS - 500 SOUTHCENTER MALL Dear TIM SCHENK, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Comcheck software is not verifiable to meet Washington State Energy code. Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Forms for Commercial Buildings available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). 2. Please provide a North Arrow on the floor plan. 3. Wall types legend refer to sheet A500 details 2,4, and 5 which could not be found or not correctly referenced. Please clarify and provide the wall details. 4. On the floor plan right side of the tenant space shows next to the double doors a door that appears to open to a wall. Please clarify. How is that space accessed? 5. At that same right side of the tenant space shows walls closing off a space creating a large concealed space behind the new wall. Provide details for that space indicating any necessary fire blocking and specifying no combustible materials shall be permitted in that space. Verify the space does not block any required access to other systems. (IBC 718.2.2, 718.5, and IFC 703.1) 6. The floor plan appears to be missing existing walls along a corridor (top of the tenant space). Please provide more clarification and show all access openings, existing walls, name corridors etc. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 i QQ Note: In response to cor et -Lions for this permit -plan -review, other corrections may be needed. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachelle Ripley V Permit Technician File No. DI7-0131 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY c) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0131 DATE: 06/28/17 PROJECT NAME: LENSCRAFTERS SITE ADDRESS: 500 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �j i (e Building Division wi Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator U PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/29/17 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07/27/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/15/2013 PERMIT COORD COPY: d PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0131 DATE: 05/18/17 PROJECT NAME: LENSCRAFTERS SITE ADDRESS: 500 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AT Coei& Building Division Public Wbrks AA Awc Fire Prevention • Structural (9-S-17 Planning Division Permit Coordinator al PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 05/23/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 06/20/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Fire 0 Ping 0 PW 0 Staff Initials: N/ 12/18/2013 City of Tukwila C REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard. Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6/20/2017 Plan Check/Permit Number: D17-0131 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # _1_ • RECEIVED ❑ Revision # after Permit is Issued CITY OF TUKWILA ❑ Revision requested by a City Building Inspector or Plans Examiner JUN 2 8 2017 ❑ Deferred Submittal # PERMIT CENTER Project Name: LENSCRAFTERS Project Address: 500 SOUTHCENTER MALL Contact Person: David Farrington Phone Number: 860-614-2538 Summary of Revision: 1. Washington energy code forms have been provided. 2. North arrows have been added on V000 ((Macy's floor plan) and A100 (Fixture Plan). 3. Wall types are on plan A101, and the details are referenced in box 5 "Wall Type Legend" on sheet A101. Additional wall type D was added to clarify the wall at the void space in item 5 (see plan A101 and detail 6/A300). 4. Door in question is existing, and outside area of permitted work. It is currently not used, and opens to a wall, as shown on the drawings. The existing void space has been called out to clarify the existing situation. We have called for a sign to be placed on the door stating the door is not an exit. See A101. 5. We have called for required blocking, noted the void space, and noted that no combustible materials are allowed within the void space. See A101. 6. The lines in question indicate the edges of the existing Macy's major traffic aisles, not walls. We have attempted to clarify by labeling the surrounding areas on A100. Sheet Number(s): V000, A100, A101, A300 "Cloud" or highlight all areas of revision including date of rev'sion Received at the -City of Tukwila Permit Center by: ❑ Entered in TRAKiT on CAU.serAtachelle-12Uksktop\Revision Submittal Form - D10-ninS.d ,c Revised: August 2015 OAKSTONE CONSTRUCTION I r Home. Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 2 r °clai A -"Z index Help My 1,&-I Workplace Rights Trades & Licensing OAKSTONE CONSTRUCTION INC Owner or tradesperson Principals KREISL, WILLIAM ANTHONY, PRESIDENT MARKWELL, CHARLES, AGENT (End: 05/21/2010) Doing business as OAKSTONE CONSTRUCTION INC WA UBI No. 602 190 669 4065 YOSEMITE PL PLACERVILLE, CA 95667 530-642-8858 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....._.............................................................. Meets current requirements. License specialties GENERAL License no. OAKSTCI988KC Effective — expiration 05/24/2002— 05/24/2018 Bond ..._........... CBIC Bond account no. CD7268 $12,000.00 Received by L&I Effective date 05/03/2002 05/01/2002 Expiration date Until Canceled Insurance Endurance American Specialty! $1,000,000.00 Policy no. CBF10000150300 Received by L&I Effective date 03/28/2017 04/01/2017 Expiration date 04/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602190669&LIC=OAKSTCI988KC&SAW= 7/24/2017 OAKSTONE CONSTRUCTION INA �� No L&I tax debts are recorded for this contra( 'tcense during the previous 6 year period, but some d` may be recorded by other agencies. License Violations .................................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 1..22,028-02 ............................. Doing business as OAKSTONE CONSTRUCTION INC Estimated workers reported Quarter 2 of Year 2017 "0" Workers L&I account contact T4 / STEPHEN TASSONI (360)902-4819 - Email: TASS235@lni.wa.gov Track this contractor,,? Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................................................ No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602190669&LIC=OAKSTCI988KC&SAW= 7/24/2017 DESIGN & CONSTRUCTION MANAGEMENT: RE 0 4000 Luxottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 0 +1 (513) 765-6000 0 +1(516) 393-2484 Store #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for O QO Imum L(90 2 O n3 OO O N 0 �' V CL. CanO In 0 LLI Qentni cD Macy's Store Number Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com 4/7/2017 Architect/ Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: ®Client Review ®DOB Permit ❑DOB Permit - Re -Submit ® LL Approval II Bid II Construction Title GENERAL INFORMATION COVER SHEET Date Q4/06/2017 Drawn By SEV Checked By DAF Sheet G001 .,n„t, RESPO SIBII `I` ”' SCHEDULE Drawings for: T= TENANTr NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE GC= GENERAL CONTRACTOR SHALL BE REPORTED TO LUXOTTICA PROJECT MANAGER IMMEDIATELY. QUOS ` MW= MILLWORKER FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES 4 9'.'0� cv LL= LANDLORDRA 4 * Qom, 4,, N/A= NOT APPLICABLE , t N S` T RS DIVISION 01000 - GENERAL SUPL ACV. INSTL EX'G RELO REMARKSr ,yt ,�t" BUILDING PERMIT T GC GC SHALL AMEND / PICK UP PERMIT & PAY ADD'TL FEES; FEES BILLABLE TO NEXTORE AT NET COST; VIA CHANGE ORDER #1 PROFESSIONAL CLEAN-UP, FINAL CLEANING GC GC (2) CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER A i ` , the Luxottica Group DEMOLITION GC GC FIELD VERIFY EXISTING CONDITIONS AND SEE PLANS FOR SCOPE ♦�/ of TEMPORARY FACILITIES / UTILITIES GC GC GC IF REQUIRED OTHER PERMITS, FEES, INSURANCE GC GC INCLUDING ALL LOCAL PEST CONTROL REQUIREMENTS, PERMITS, VERIFY REQUIREMENTS 4000 Luxottica Place Mason Ohio 45040 TEMPORARY BARRICADES (W/ LUX BRAND SPECIFIC LOGO) GC GC COORDINATE WITH LANDLORD. LOGO SUPPLIED BY TENANT, INSTALLED BY GC TRASH REMOVAL AND DUMPSTERS GC GC VERIFY TOWN AND LANDLORD REQUIREMENTS. GC. TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED. • CUTTING AND PATCHING GC GC GC RELOCATION OF EXISTING MACY'S FIXTURES LL LL GC TO VERIFY UPON ARRIVAL ON JOB SITE THAT THE SITE HAS BEEN CLEARED OF ALL MAC'Y FIXTURES IN ORDER TO PERMORM AREA CONSTRUCTION. NOTIFY NEXTORE PROJECT MANAGER OF ANY QUESTIONABLE ITEMS EXISTING. S 0 U CENTER ASSET PROTECTION COORDINATION GC IF OVERNIGHTS REQUIRED, GC SHALL PAY AP VENDOR & COORDINATE OVERNIGHT POWER W OPS MANAGER. INSURANCE GC GC TO ADD MACYS AS AN ADDITIONALLY INSURED PARTY ON CERTIFICATE OF LIABILITY INSURANCE. CERTIFICATES NEED TO BE SENT TO THE NEXTORE PROJECT MANAGER. NEXTORE PROJECT MANAGER TO FORWARD TO THE MACY'S PROJECT MANAGER. REVISIONS _, DIVISION 03000 - CONCRETE SUPL RCV. INSTL EX'G RELO REMARKSr:: 1'nte$ Gllbtl �TA'�Ld@ to the SC�?DC U KWILA, WA CONCRETE SLAB (NEW OR PATCH FILL) GC GC GC 0 G.C. TO FIELD VERIFY EXIST. COND. TO DETERMINE EXTENTS OF SCOPE. GC TO REPORT TO PROJECT MANAGER. r p 4•�O`" ^'ihtes I�` tOC approval of CUTTING OF EXISTING SLAB -TRENCHING OR CORE DRILLING GC GC GC COORD. W/ LANDLORD & AFFECTED TENANTS. VERIFY W MACY'S OPERATIONS PRIOR TO ANY CORING OR TRENCHING. f t )'S+ t l�+• GLI Division. SIDEWALK AT EXTERIOR DOOR GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION & MATERIAL TO COMPLETE EXTERIOR SIDEWALK WHEN APPLICABLE. , • i 7R� ! T• T will IC:qu to ! DIVISION 04000 - MASONRY SUPL RCV. INSTL EX'G RELO REMARKS ..::l.eJ.,..liJ a new fI'un subrntttal t + ) may lti additional NEW ENTRY OPENING GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION & MATERIAL TO COMPLETE EXTERIOR ENTRY WAY WHEN APPLICABLE. .;Ltdti plan 1e.'I bj feeS. I DIVISION 05000 - MISC. METALS SUPL RCV. INSTL EX'G RELO REMARKS BASE BUILDING STRUCTURAL STEEL 0 STRUCTURAL STEEL AS REQUIRED FOR TENANT BUILD -OUT GC GC GC METAL FABRICATIONS N/A 1 EXPANSION JOINTS GC GC GC 2 LANDLORD'S S ADDRESS 3 JOB SITE ADDRESS 4 MACYS KEY PLAN VICINITY AN DIVISION 06000 - WOOD & PLASTICS SUPL RCV. INSTL EX'G RELO REMARKS LANDLORD MACY'S CORPORATE SERVICES NAME MACY'S BLOCKING (INCL. FOR FIXTURES, SHELVES, SIGNS GC GC GC FIRE RETARDENT WOOD AND OR METAL PER AUTHORITY JURISDICTION / LL ROUGH CARPENTRY, FIRE RETARDANT LUMBER & PLYWD GC GC GC CONST. COORDINATOR STREET ADDRESS 500 SOUTHCENTER MALL LOCATION OF PROPOSED FLOOR PROTECTION REQUIRED) GC GC GC DURABLE PROTECTION REQUIRED. PROVIDE WALK -OFF MAT AT BOTH SIDE OF ENTRY POINT(S) OF CONSTRUCTION AREA PROJECT NEW LENS CRAFTERS PAD (IF STREET ADDRESS 7 WEST SEVENTH STREET CITY, STATE, ZIP TUKWILA, WA 98188 FINISH CARPENTRY GC GC GC "4• LOCATION CITY, STATE, ZIP CINCINNATI OH, 45202 SPACE NUMBER - .• • Pink III\\71ME��'�\� _y' DIVISION 07000 - THERMAL & MOISTURE PROTECTION SUPL RCV. INSTL EX'G RELO REMARKS PHONE LI• �►.7 U ",;;�7o1;1;217..:-Cjirj7:173.411:. • a! SEALANTS, INSULATION, FIRE CAULKING & BLOCKNGGC GC GCSEE SPECIFICATIONS -`' �ri/SPRAYED EMAIL.���� FIRE RESISTIVE MATERIALSGC GC GCIF REQUIRED BY LL��`THROUGH PENETRATIONS FIRE STOP SYSTEMGC GC GC ,a,,BATT LCM17 G001 REVO1 3 LCM17 G001 REV00 INSULATION AND/OR SOUND ATTENUATIONGC GC GC2 �,+�rsg �k tcmdingT F WATERPRO F MEMBRANE SHALL BE VERIFIED W LL BY THE GC O O ,•r = �— )epadrrantsto eWATERPROOF MEMBRANEGC GC GC EXTEN t c,,,.���SUPL It RCV INSTL EX'G RELO REMARKS - {yy CJ� ® DIVISION 08000 DOORS & WINDOWS CCr< :: (� .:. Seattle Team am Shc�>) NEW DOORS, FRAMES, HARDWARE GC GC GC UNLESS NOTED OTHERWISE. (SEE DOOR SCHEDULE SHEET A101) V, , STORE . INFO.- 7 ,,, U RIS DICTIO `„ ���� lu„� • �� _ 1 �.� PANIC / SECURITY ALARM GC GC GC IF EGRESS DOOR REQUIRED �;`►.�..�^���` Ells Restaurant INTERIOR DOOR LOCK CORES AND KEYS T GC GC Express, lnc.i & Brewhousc� ACCESS DOORS AND FRAMES GC GC GC CITY CITY OF TUKWILA ` 1 MILLWORK MIRRORS T GC GC STREET ADDRESS 500 SOUTHCENTER MALL DEPARTMENT TUKWILA COMMUNITY DEVELOPMENT DEPARTMENT �•��,`,���+� NORTH DIVISION 09000 - FINISHES SUPL RCV. INSTL EX'G RELO REMARKS CITY, STATE, ZIP'�/!� TUKWILA, WA 98188 STREET ADDRESS 6300 SOUTHCENTER BLVD • NEW DEMISING PARTITIONS (STUDS & INSTALLATION) GC GC GC SEE PLANS FOR SCOPE OF WORK PHONE 656 6000 CITY, STATE, ZIP I 11 (425) TUKWILA, WA 98188 NEW DEMISING PARTITIONS (GYPSUM WALLBOARD) GC GC GC SEE PLANS FOR SCOPE OF WORK. DRYWALL CEILING, WALLS, ENCLOSURES & REQ'D FRAMING GC GC GC PER USG AESTHETIC ASSEMBLIES, ALL WALLS (INCLUDING EXISTING TO REMAIN), SHALL RECEIVE "LEVEL 4" FINISH, & CEIL "LEVEL 5" PHONE (206) 431-3670 „ ACOUSTICAL CEILING 2'x2' TILES & GRID GC GC GC PAINTING, FINISHING, VARNISH, SEALER, ETC. GC GC GC 6-LCM17-G001-REVO1 7-LCM17-G001-REV00 4-LCM17-G001-REV00 5-LCM17-G001-REV00 FLOOR TRANSITIONS/VINYL TILE /VINYL WALL BASE GC GC GC VINYL BASE @ ROUND COLUMNS CARPET TILE C-63 T GC GC GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. REFER TO FINISH SCHEDULE SHEET A103. CARPET (OTHER THAN C-63) GC GC GC GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. REFER TFINISHH SCHEDULE SHEET A 103. CONSTRUCTION OF THE NEW LENSCRAFTERS PORCELAIN FLOOR TILE T GC GC GCMUST INSTALL FLOOR PER FLOORING MFG SPECS. CODE I R ON DEPT. NO CHANGE OF EGRESS OF OR PR3JCT DIRECT)R dRAVI INDEX GROUT AND THINSET FOR TILE & ACCESSORIES GC GC GC OCCUPANCY OF THE MACY'S STORE. FLOORING TRANSITION STRIPS GC GC GC ACTIVE T GC GC CONSTRUCTION TYPE: TYPE IIB, UNPROTECTED DRAWING TITLE WALLCOVERING WC105 REVISION # WALLCOVERING WC106 GC GC GC EXISTING OCCUPANCY: NON SEPARATED MIXED USE (M, B, 5) DESIGN AND CONSTRUCTION MANAGEMENT GC TO OBTAIN LENSCRAFTERS / MACYS CONSTRUCTION CRITERIA REV0.0 PORCELAIN WALL TILE T GC GC CUSTOM WOOD MILLWORK WD201 T GC T PROPOSED OCCUPANCY: NO CHANGE NON SEPARATED MIXED USE (M, B, 5) NEXTORE NEXTORE 3/4" X 3/4" WOOD TRIM GC GC GC BUILDING: 2015 INTERNATIONAL BUILDING CODE ARCHITECTURAL TRIM DOOR SURROUND) GC GC GC 6 CREAMERY BROOK 4000 LUXOTTICA PLACE WOOD (OPEN MECHANICAL: 2015 INTERNATIONAL MECHANICAL CODE EAST GRANBY, CT 06026 MASON, OH 45040 G001 GENERAL INFORMATION / COVER SHEET . WOOD BASEBOARD WB101 &WB102 GC GC GC PAINTED P104 CHAIR RAIL GC GC GC FIRE: 2015 INTERNATIONAL FIRE CODE 516.393.2484 513.765.6000 V000 MACY'S FLOOR PLAN - PLUMBING: 2015 UNIFORM PLUMBING CODE DIVISION 10000 - SPECIALTIES SUPL RCV. INSTL EX'G RELO REMARKS AD100 EXISTING FLOOR PLAN DEMOLITION T GC GC SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION ELECTRICAL 2014 NATIONAL El ECTRICAL CODE RETAIL WALL SIGNAGE NEXTORE PROJECT MGR. NEXTORE STORE PLANNER AD20o EXISTING CEILING PLAN DEMOLITION GRAPHIC HOLDER T GC GC SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION ENERGY: 2015 WASHINGTON STATE ENERGY CODE RON WENDUS JULIE NOTO GRAPHICS T GC GC SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATIONA100 513-387 3363 516-393 2499 FIXTURE - FLOOR PLAN - ACCESSIBILITY SIGNAGE T GC GC SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION ACCESSIBILITY CODE: ANSI 117.1 RWENDUS@NEXTORERETAIL.COM JNOTO@NEXTORERETALCOM STORAGE AREA SHELVES & SURFACE MTD. STANDARDS GC GC GC A101 CONSTRUCTION - FLOOR PLAN FIRE EXTINGUISHERS GC GC GC SUGGESTED LOCATION ON PLAN - VERIFY LOCAL REQUIREMENTSA102 REFLECTED CEILING PLAN _ GLAZING FILM - EXTERIOR GRAPHICS T T T EGRESS CAPAUIIES FULLY SPRINKLERED: YES 1. EGRESS COMPONENTS: A103 FINISH PLAN - DIVISION 12000 - FURNISHINGS SUPL RCV. INSTL EX'G RELO REMARKS FIRE ALARM: YES DOORS, CORRIDORS = 0.2 INCHES PER OCCUPANT FIRE EXTINGUISHERS: YES SEE SHEET A100 FOR LOCATIONS A200 INTERIOR ELEVATIONS RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT. CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ. NEXTORE STORE DESIGNER ARCHITECT MILLWORK (RETAIL) T GC T SPRINKLERED STAIRS = 0.3 INCHES PER OCCUPANT MILLWORK (O.D.) T GC T RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT. CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ. CASSANDRA HANLIN MATTHEW D. WITTMER A300 SECTIONS OCCUPANCY CALCULATIONS : 12 CANAAN WAY OD EQUIPMENT T T T G.C. TO COORDINATE 513.765.6000 A500 DETAILS T GC T G.C. TO COORDINATE EGRESS PROVIDED: CHANLIN@NEXTORERETAIL.COM SIMSBURY, CT 06070 POS EQUIPMENT EXISTING MACY'S SECOND FLOOR AREA LENS PROCESS EQUIPMENT T T TENTRANCE DESCRIPTION AREA LOAD FACTOR OCCUPANTS #2 144" (2 PAIR 3'-0" DOORS) / 02" = 720 OCCUPANTS 860-246-1624 MERCHANDISE PROPS T GC GC (SF) ENTRANCE #3- 144" (2 PAIR 3'-0" DOORS) / 0.2" = 720 OCCUPANTS MWITTMER@PHASEZERODESIGN.COM FURNITURE (CHAIRS, BENCHES, TABLES, ETC.) T GC GC RETAIL SALES AREA 57,966 SF 30 SF / PERSON 1,932 EXIT #136"/ 0.3 = 180 OCCUPANTS MECHANICAL STAPLES PURCHASED ITEMS T GC GC BUSINESS AREA 9,245 SF 100 SF / PERSON 93 EXIT #2 36"/ 0.3 = 180 OCCUPANTS DOCTOR'S CERTIFICATES /LICENSES T GC GC STOCK AREA 4,847 SF 300 SF / PERSON 16 EXIT #3 36"/ 0.3 = 180 OCCUPANTS MPE100 OVERALL EXISTING FLOOR PLANS UNOCCUPIED SPACE 1,362 SF (SHAFTS, ETC) STAIR #1 84" / 0.3" = 280 OCCUPANTS ENGINEER DIVISION 15000 - MECHANICAL SUPL RCV. INSTL EX'G RELO REMARKS STAIR #2 84" / 0.3" = 280 OCCUPANTS TOTAL AREA 73,420 SF MIKE ROMES H2O0 HVAC PLAN ACCESS PANELS GC GC GC COORDINATE WITH TRADES FOR SIZE AND LOCATION. 2,041 920-445-5007 TO COORD. W/ LANDLORD WHEN REQUIRED ROOF WORK GC GC GC GC LIMITED AREA OF WORK @ NEW LENSCRAFTERS DEPARTMENTMROMES@NEXTORERETAIL.COM TOTAL CAPACITY: 2,540 OCCUPANTS HVAC DISTRIBUTION, DUCTWORK, DIFFUSERS GC GC GC DESCRIPTION AREA (SF) LOAD FACTOR OCCUPANTS ELECTRICAL PLUMBING FIXTURES T GC GC INCLUDING BUT NOT LIMITED TO SINKS, FAUCETS, DRAINS, ETC FLOOR DRAINS / PIPING / SUPPORTS GC GC GC RETAIL SALES AREA 632 SF 30 SF / PERSON 21 MINIMUM EXITS REQUIRED: MORE THAN 1000 OCCUPANTS = 4 EXITS REQUIRED REVIEWED FOR E100 SPECIFICATION, SYMBOLS AND DEMOLITION - CONNECTION GC GC GC 0 GC SEE PLUMBING DRAWINGS FOR SCOPE OF WORK BUSINESS AREA 294 SF 100 SF / PERSON 3 4 EXITS PROVIDED WATER AND SEWER SPRINKLER SYSTEM MODIFICATIONS GC GC GC GC BY L.L. DESIGNATED CONTRACTOR AT G.C. EXPENSE. GC RESP. FOR MODIFICATIONS, DRAWINGS, AND APPROVALS. STOCK AREA 0 SF 300 SF / PERSON SEE SHEET V000 FOR EGRESS LOCATIONS CODE COMPLIANCE E200 POWER AND LOW VOLTAGE PLANS SANITARY PUMP (ALL COMPONENTS) GC GC GC GC SHALL PURCHASE PUMP FROM NEXTORE'S REQUIRED VENDOR. SEE PLUMBING SHEETS FOR CONTACT INFORMATION. UNOCCUPIED SPACE 0 SF APPROVED SANITARY BOOSTER GC GC GC E300 DETAIL & RISER INSTA-HOT WATER HEATERS GC GC GC TOTAL AREA 926 SF 24 • ►JUN 2 0 2017 DIVISION 16000 - ELECTRICAL SUPL RCV. INSTL EX'G RELO REMARKS CONSTRUCTION OF THE NEW LENSCRAFTER DEPT. WILL NOT AFFECT THE Al--- P L A G/^ U M OI N CONNECTION AND WIRING @ MILLWORK THROUGHOUT GC GC GC ALL MILLWORK LIGHTING IS PLUG & PLAY ESTABLISHED OVERALL OCCUPANCY CALCULATION, EGRESS REQUIREMENTS, OR City of Tukwila V ELECTRICAL SERVICE CONDUIT ONLY GC GC GC PLUMBING REQUIREMENTS OF THE EXISTING MACY'S STORE. BUILDINGLDIVL. , P200 SANITARY AND VENT PLANS AND DETAILS TO REFER TO ELECTRICAL RISER DIAGRAM ELECTRICAL PANELS / TRANSFORMERS GC GC GC GC ELECTRICAL WIRING, CIRCUITING, RECEPTACLES, SWITCHES GC GC GC RECEPTACLES IN MILLWORK T T T (WIRING AND FINAL CONNECTIONS BY GC) 8 LCM17 G001 REV00 9 LCM17 G001 REV00 10 LCM17 G001 REV00 T GC GC EMERGENCY LIGHTING EXIT SIGNS T GC GC FIRE ALARM SYSTEM LL LL LL C Fr NEW LIGHT FIXTURES & LAMPS T GC GC C +�i � M E IST S 12 SCO P E� E V�'OR REPLACEMENT OR MATCHING EXISTING LIGHT FIXTURES & LAMPS GC GC GC " , .....E WIRE AND EXTEND SOUND SYSTEM SPEAKERS 0 TORELOCATE WHEN APPLICABLE MATCH EXIST. GC O / RECEIVED THIS PROJECT IS A BUILDOUT OF A NEW LENSCRAFTERS DEPARTMENT TELEPHONE CONDUIT TO SPACE T T T SEPARATEPERMIT �^�'�'Y O� TUKWILA WITHIN AN EXISTING MACY'S DEPARTMENT STORE. NO CHANGES IN OCCUPANCY, OVERALL TELEPHONE WIRING TO SPACE T T T WIRING TO BE PLENUM RATED ,.��• ry Plan rBVf'+�r C;? IhOti`L ! I subtest to and a�I:h �I£r"I - I I'(.�QU�AED SQUARE FOOTAGE, OR STRUCTURAL WORK IS PROPOSED. WORK IS LIMITED TO THE TENANT TELEPHONE EQUIPMENT T T T G.C. TO COORDINATE Approval of Goi'l`�^EILsCtion documents does not L-:utho;i.�s'1 FOR: AREA INDICATED ON SHEET V000. TELEPHONE WIRING T T T WIRING TO BE PLENUM RATED 1 MAY g 2011 i THE SCOPE OF WORK INCLUDES: CONDUITS - DATA, COMMUNICATION, ALARMS, PHONES GC GC GC TENANT'S LOW VOLTAGE VENDOR PERFORMS DATA TERMINATIONS the violation of any adopted code or ord ! 'nco. ReC ;fist eChanical • CONSTRUCTION OF NEW NON LOAD BEARING WALLS POS AND DATA WIRING T T T GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. WIRING TO BE PLENUM RATED of approved Flbid . -1T/,=rte to,* S is acknpt, ledoyrj_ PERT CENTER • NEW FLOORING FINISHES WIRELESS EQUIPMENT T T T I-N'r+Iect{'Ica) URIbin g • MODIFIED & NEW CEILINGS JACK TERMINATION & FACEPLATE - DATA T T T GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. f/ r Q1•. Gas Piping • NEW FURNITURE AND FIXTURES MACY'S BACKBOARD TERMINATION - DATA T T T • NEW OD OFFICE EQUIPMENT JACK TERMINATION & FACEPLATE - PHONE T T T GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. Date: 7 .2City of Tukwila • NEW SIGNAGE AND GRAPHICS • NEW ELECTRICAL SUBPANEL & LOCAL DISTRIBUTION MACY'S BACKBOARD TERMINATION - PHONE T T T �,{' It"I DIVISION 1 3 I • NEW HAND SINKS (2) AND ASSOCIATED PLUMBING COORDINATE W/ LL & NEXTORE PM (.�'I'i, SECURITY FACILITY (HARDWARE & WIRING) GC GC GC 1-LCM17-G001-REV00 City of Tukwila0 11-LCM17-G001-REV00 BUILDING-DIVISION12-LCM17-G001-REV00 • MODIFICATION TO EXISTING DUCT DISTRIBUTION SYSTEM • UTILITY WORK AS REQUIRED TO ACCOMMODATE PROJECT SCOPE DESIGN & CONSTRUCTION MANAGEMENT: RE 0 4000 Luxottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 0 +1 (513) 765-6000 0 +1(516) 393-2484 Store #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for O QO Imum L(90 2 O n3 OO O N 0 �' V CL. CanO In 0 LLI Qentni cD Macy's Store Number Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com 4/7/2017 Architect/ Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: ®Client Review ®DOB Permit ❑DOB Permit - Re -Submit ® LL Approval II Bid II Construction Title GENERAL INFORMATION COVER SHEET Date Q4/06/2017 Drawn By SEV Checked By DAF Sheet G001 EXIT #1 '111111111""' EMPLOYEE ENTRANCE CUSTOMER PICKUP 0 ENTRANCE #2 20% ""'j11I11u1" ENTRANCE #3 10% "111111 LENS CRAFTERS LOCATION -=-0--ATH OF EGRESS' "i'IIiIII111,0 111111111v Existing Macy's Basement Plan SCALE: 1/16" =1,-0" br7o13; REVIEWED FOR ODE COMPLIANCE APPROVED IJUN 2 9 2017 City of Tukwila BUILDING DIVISION CORRECTION LTR# RECEIVED CITY OF TUKWILA JUN 28 2017 PERMIT CENTER DESIGN & CONSTRUCTION MANAGEMENT: RE 0 4000 Luxottica Place, Masco, OH 45040 0 6 Creamery Brook, East Grantr, CT06026 0 +1(513) 765-6000 0 +1(516) 393-2484 stare 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: unsi 0 U a) 10 Ll d- 0 C 0 to (6 (1) U (i3 0 Macy's Store Number: Revisions: Mark Date By 1 4/10/17 ST CUENT COMMENTS ` \ 6/02/2017 SNT CUENT COMMENTS / ' \ 6/15/2017 SEV CITY COMMENTS A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 6/16/261? Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑ Client Review ❑DOB Permit ❑ DOB Permit - Re -Submit ❑ LL Approval ❑ Bid ® Construction Title MACY'S FLOOR PLAN BASEMENT FLOOR Date 04/06/2017 Drawn By Checked By DAF Sheet V000 57'-102" CC) da Ura man an MEM aaa a IMO a mama ■ aaa P 5'-0" 0 5'-0" • mama a ■naa a as as as P arrrNM as - flail -nal 00 H O O m 4'-6" 1 EXISTING FLOOR PLAN / DEMOLITION SCALE: 1/4" = 1'-0" 4 WALL TYPE LEGEND 0 GENERAL: REPRESENTATIVES CENTER LINE OF THE LENS CRAFTERS AREA. COORDINATE WITH MACY'S FACILITIES CLEAN, SCRAPE, AND REMOVE ALL PREP REQUIREMENTS. 1. EXISTING 2. EXISTING 3. EXISTING ADHESIVES 4. EXISTING 5. EXISTING CTC. BACK TO CONCRETE SLAB. FOR NEW FLOORING LEASE LINE FROM ADJACENT MACY'S ARCA. COORDINATE ON SITE WiTI I MACY'S PCPRCSCNTAI7VC FOR EXACT DIMENSIONS AND ANY EXISTING ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND ® •. • • :: LI FLOORING TO RCMAIN. 7. EXISTING PARTITIONS AND DOORS ,HARDWARE TO BE REMOVED WHERE INDICATED. MADE SAFE. CONSTRUCTION TO BE DEMOLISHED — — ® ® ANDFLAT SURFACE (LEVEL 4'INISI . 10. REMOVE SECTION OF EXISTING DISPLAY AREA ALUMINUM 'TAMING AND GLASS AS BARRICADE TEMPORARY CONSTRUCTION FILM TO REMAINING DISPLAY GLASS AS REQUIRED. 11. G.C. TO PROVIDE TEMP CONSTRUCTION BARRICADE. G.C. TO FIELD DETERMINE EXACT SCOPE OF WORK. COORDINATE LOCATION OF A 3' OPENING FOR ACCESS. WITH MACY'S FLOORING ON BOTH SIDES OF THE BARRICADE. SEE TYPICAL DETAIL THIS SHEET. 12. G.C. TO PROVIDE DUST BARRIER (FLAME RETARDANT POLY TARP HEAVY DUTY) MEETING 13. LEASE LINE 14. MACY'S CARPETING TO REMAIN. NO WORK. 15. PROVIDE DOOR IN BARRICADE FOR ACCESS TO MACY'S SPRINKLER ROOM. SUPPLY MAINTAIN MACY'S ACCESS TO SPRINKLER ROOM AT ALL TIMES. 16. MACY'S SPRINKLER ROOM. NO WORK THIS AREA. 17. MACY'S EGRESS STAIR TO REMAIN. NO WORK THIS AREA. REVIEWED FOR CODE COMPLIANCE APPROVED ,. 1JUN 29 2011 City of Tukwila BUILDING DIVISION 4-LCM17-AD100-REV00 EXISTING WALLS TO REMAIN EXISTING MASONRY WALLS TO REMAIN • • -4 - - - Q -, - -. - 3-LCM17-AD100-REV00 TEMPORARY BARRICADE • TEMPORARY BARRICADE SHALL BE CONSTRUCTED PER LL REQUIREMENTS • TEMPORARY BARRICADE IS TO BE 100% COMPLETE AND READY FOR GRAPHICS TO BE INSTALLED NO MORE THAN (2) DAYS AFTER CONSTRUCTION START. G.C. TO CONTACT OWNERS REPRESENTATIVE UPON COMPLETION TO COORDINATE GRAPHICS INSTALLATION. TEMPORARY BARRICADE MUST BE PRIMED AND PAINTED WITH (2) COATS OF EITHER EGGSHELL OR SEMI -GLOSS FINISH ONLY. • GC IS RESPONSIBLE FOR MAINTAINING BARRICADE DURING CONSTRUCTION. • REMOVE BARRICADE WHEN 100% OF STOREFRONT OR JOB IS COMPLETED ON THE EVENING BEFORE G.C.'S PUNCHUST IS COMPLETED, PRIOR TO OWNER VERIFICATION, AND AFTER LL APPROVAL IS RECEIVED. CARE IS TO BE TAKEN WHEN DISSEMBLING AND REMOVING BARRICADE, ON INTERIOR SIDE (STORE SIDE), PAPER WINDOWS WITH WHITE CONSTRUCTION PAPER OVER GLAZING ONLY. TRIM 1/T OFF EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER WITH WHITE TAPE. G.C. IS TO RESTORE NEUTRAL PIER(S), MALL FLOORING & BULKHEAD TO A LIKE NEW CONDITION AND FINISH WHERE APPLICABLE. 24" AT CARPET: 3 8" X 25 GA METAL TRACK SECURED TO 3/4" PLYWOOD W/ SCREWS @ 48" O.C.; PROVIDE WEIGHT (MULTIPLE SAND BAGS SPACED) AS REQUIRED FOR TEMP WALL STABILITY. op 0 ccz m� 0 cc CLEAR PLASTIC OR FIRE RATED TARP AS REQUIRED 3 5/8" x 20 GA. METAL STUDS AT 24" O.C. w/ 1/2" GWB (1) SIDE TO 4'-0" A.F.F.; GC TO PAINT STORE SIDE WHITE, LEVEL 3 FINISH. 3 $" X 25 GA METAL STUD DIAGONAL BRACING @ 48" O.C. 4" FRT PLYWOOD EXIST. CELL. CONSTRUCTION SIDE AT TILE: 3$"X25GAMETAL TRACK SECURE TO FLOOR WITH CONCRETE SCREWS @ 48" O.C. IN GROUT JOINTS. PATCH AND REPAIR GROUT JOINTS UPON REMOVAL. 2-LCM17-AD100-REV00 2 KEY NOTES 0 GENERAL: REPRESENTATIVES G.C. TO FIELD VERIFY IF ANY EXISTING STORE FIXTURES ARE WITH -IN THE LIMITS AND HAVE REMOVED. ARCA TO RCMAIN INCLUDING ALL rIXTURCS, fINISI ICS, FLOORING, OF THE LENS CRAFTERS AREA. COORDINATE WITH MACY'S FACILITIES CLEAN, SCRAPE, AND REMOVE ALL PREP REQUIREMENTS. 1. EXISTING 2. EXISTING 3. EXISTING ADHESIVES 4. EXISTING 5. EXISTING CTC. BACK TO CONCRETE SLAB. FOR NEW FLOORING PARTITION TO REMAIN ALONG WITH DOOR, FRAME, AND HARDWARE. - CARPET AND WALL BASE IN PROPOSED LENS CRAFTER'S AREA LIMITS TO BE REMOVED AS REQUIRED FOR NEW FLOOR INSTALLATION. COORDINATE WITH MFG REQUIREMENTS MACY'S TILE FLOORING TO REMAIN. CARPETING TO BE REMOVED FROM ADJACENT MACY'S ARCA. COORDINATE ON SITE WiTI I MACY'S PCPRCSCNTAI7VC FOR EXACT DIMENSIONS AND ANY EXISTING ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND TIMING SCI ICDULC Of DEMOLITION. - 'LANK •. • • :: LI FLOORING TO RCMAIN. 7. EXISTING PARTITIONS AND DOORS ,HARDWARE TO BE REMOVED WHERE INDICATED. MADE SAFE. B. EXISTING MILLWORK DMDCRS TO BC REMOVED. ANDFLAT SURFACE (LEVEL 4'INISI . 10. REMOVE SECTION OF EXISTING DISPLAY AREA ALUMINUM 'TAMING AND GLASS AS INDICATED. NOTE: COORDINATE WITI I MACY'S REPRESENTATIVE AND APPLY CONFIGURATION OF BARRICADE AS NECESSARY TO COMPLETE THE OVERALL AND NEXTORE REPRESENTITIVES. G.C. IS TO PROTECT THE EXISTING THE FIRE RESISTANCE REQUIREMENTS OF NFPA 241, SEE DETAIL THIS SHEET. AND INSTALL SIGN ON DOOR IDENTIFYING "SPRINKLER ROOM ACCESS" TEMPORARY CONSTRUCTION FILM TO REMAINING DISPLAY GLASS AS REQUIRED. 11. G.C. TO PROVIDE TEMP CONSTRUCTION BARRICADE. G.C. TO FIELD DETERMINE EXACT SCOPE OF WORK. COORDINATE LOCATION OF A 3' OPENING FOR ACCESS. WITH MACY'S FLOORING ON BOTH SIDES OF THE BARRICADE. SEE TYPICAL DETAIL THIS SHEET. 12. G.C. TO PROVIDE DUST BARRIER (FLAME RETARDANT POLY TARP HEAVY DUTY) MEETING 13. LEASE LINE 14. MACY'S CARPETING TO REMAIN. NO WORK. 15. PROVIDE DOOR IN BARRICADE FOR ACCESS TO MACY'S SPRINKLER ROOM. SUPPLY MAINTAIN MACY'S ACCESS TO SPRINKLER ROOM AT ALL TIMES. 16. MACY'S SPRINKLER ROOM. NO WORK THIS AREA. 17. MACY'S EGRESS STAIR TO REMAIN. NO WORK THIS AREA. REVIEWED FOR CODE COMPLIANCE APPROVED ,. 1JUN 29 2011 City of Tukwila BUILDING DIVISION 4-LCM17-AD100-REV00 A. THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. B. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. C. THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. D. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. E. REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT; REFER TO RESPONSIBILITY SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION. F. AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE NEXTORE'S PROJECT MANAGER'S APPROVAL. G. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN IN THE BID. H. EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID PACKAGES. I. J. K. L. M. N. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C. ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS; REFER TO DOOR SCHEDULE. ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL DRAWINGS. REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES. G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT SPECIFICATIONS. G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE PER DETAIL. SUBJECT TO CHANGE PER MACY'S REQUIREMENTS. GC TO ITEMIZE COST OF BARRICADE. O. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. RE IVED 0 TUKWILA 82011 MI ENTER 5-LCM17-AD100-REV00 DESIGN & CONSTRUCTION MANAGEMENT: RE ® 4000 Luxottica Place, Mason, 01-145040 ® 6 Creamery Brook, East Granby, CT 06026 ®+1 (513) 765-6000 0 +1 (516) 393-2484 Stare 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: .cn >• CD Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: IBI Client Review XI DOB Permit 0 DOB Permit - Re -Submit ® LL Approval ® Bid ® Construction Title EXISTING FLOOR PLAN / DEMO Date 04/06/2017 Drawn By SEV Checked By DAF Sheet AD100 • • • 10 MRS W • ■ Isom ■ s 1 10 L 3 L L 3 9 r 1 X lat 4k Uuoo .1•1111111111111111111.11•1•111111•11•111 WWWWWWWW INN i S'-0" i 31' 32" 1 EXISTING CEILING PLAN / DEMO SCALE: 1/4' = 1'-0' 1. EXISTING MACY'S CEILINGS TO REMAIN INCLUDING , GYP. BD. CEILINGS, ALL LIGHTING, AUDIO SPEAKERS, AND HVAC DIFFUSERS TO REMAIN UNLESS OTHERWISE NOTED. 2. EXISTING DRYWALL CEILINGS TO REMAIN ALONG WITH ALL LIGHTING FIXTURES AND HVAC DIFFUSERS UNLESS NOTED OTHERWISE. CLEAN AND RELAMP EXISTING FIXTURES AS REQUIRED. 3. REMOVE EXISTING LIGHT FIXTURE AS INDICATED. RETURN FIXTURE TO MACY'S REPRESENTATIVE. ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND MADE SAFE. 4. REMOVE EXISTING SPEAKER AS INDICATED. QUIRCD. 6. EXISTING AREA OF SUSPENDED AND GYP BD. CEILING TO BE REMOVED AS INDICATED INCLUDING ALL LIGHT FIXTURES, SPRINKLER HEADS, DIFFUSERS, ETC. EXISTING GYP BD. SUSPENDED GRID TO REMAIN. ALL FIXTURES TO BE RETURNED TO MACY'S REPRESENTATIVE. ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND MADE SAFE. AREAS OF GYP. CEILINGS TO BE REMOVED IS SHOWN HATCHED. 7. REMOVE LIGHT FIXTURES. FIXTURE TO BE RELOCATED. SEE CEILING PLAN SHEET A102 FOR NEW LOCATIONS. {LCCTRICAL BACK TO POINT OF SCRVICE. 9. EXISTING MACY'S CEILING TO REMAIN. MODIFY AND PATCH INTO NEW CONSTRUCTION AS REQUIRED. 10. LEASE LINE REVIEWED FOR CODE COMPLIANCE APPROVED I JUN 2 9 2017 City of Tukwila BUILDING DIVISION 1-LCM17-AD200-REVOO 2 X 2 / 9 CELL PARABOLIC LIGHT FIXTURE WITH (2) 28 WATT U -BENT FLUORESCENT LAMPS RECESSED ADJUSTABLE DOWN LIGHTNG WITH TWIN TUBE COMPACT FLUORESCENT LAMPS EWV ( ( EXISTING TRACK LIGHTING EXISTING AUDIO SPEAKER EXISTING WALL WASH LIGHTING EXISTING VALANCE WALL WASH LIGHTING 0 X 1 EXISTING HORN STROBE EXISTING SPRINKLER HEADS EXISTING SPRINKLER HEADS TO BE RELOCATED EXISTING SUPPLY AIR DIFFUSER RECEIVED CITY OF TUKWILA MAY 18 2017 .72/ERMIT CENTER 2-LCM17-AD200-REVO0 DESIGN & CONSTRUCTION MANAGEMENT: RE ® 4000 Luxottica Place, Mason, OH 45040 ® 6 Creamery Brook, East Granby, CT 06026 O +1 (513) 765-6000 0.1 (516) 393-2484 Stare #8932 SOUTHCENTER. 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for 91( Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer©phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: ® Client Review ® DOB Permit 0 DOB Permit - Re -Submit ® LI. Approval IBI Bid ® Construction Title EXISTING CEILING PLAN / DEMO Date 04/06/2017. Drawn By SEV Checked By DAF Sheet AD200 MACY'S LADY'S CLOTHING DEPARTMEN A 1110101080 eoreeLw. MACY'S LADY'S CLOTHING DEPARTMENT MACY'S HALLWAY 104 CLG. HT.= 10'-0" CONTACT LENS 104 CLG. HT = 10'-0" FIXTURE - FLOOR PLAN u) -LULU 4'-6" 1'-6" 00-1181 E O 00440-00 D/EX i0 rn 0 s [76 0430-00 0430-00 0451-00 0400 00 5'-0" AD/EX 0430-00 0400-00 0321b0 5'-0" P 0430-00 0430-00 0451-00 0420-00 0 0° O 3,-4" ,mS 3'-22" E 0801-00 LCM-MW-CS.2 080-00 XB-DFQ55 0440-00835-00 0821-00 0440-00 0430-00 0420-00 0400-00 3 RETAIL SALES AREA NMI* r — ► 3�� i 846 00 Q121_F ® 61103 Ip 1 100 CLG. HT = VARIES 03 ACY'S LADY'S CLOTHING DEPARTMENT J SCALE: 1/4' = 1'-0' OPTICAL STATION 103 CLG. HT.= 10'-0" PRETEST 102 CLG. HT = 10'-0" EXAM ROOM 101 CLG. HT = 10'-0" A. G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, WALL CABINETS, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS. B. G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION. C. G.C. TO PROVIDE ADEQUATE BRACING, AS REQUIRED, IN WALLS TO SUPPORT WALL CABINETS AND FIXTURES. D. G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT ONLY. E. G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED DAMAGES" ON IT. F. G.C. TO REFER TO GRAPHICS STANDARD MANUAL FOR GRAPHIC MOUNTING HEIGHTS, TYPICAL. G. E = EXISTING TO REMAIN. M = EXISTING TO BE RELOCATED. F= FUTURE EQUIPMENT H. REFER TO ELEVATION SHEETS A200 -A201 FOR ACCESSIBILITY ACCESS SIGNAGE 3-LCM17-A100-REVO0 CAPACITY CALCULATIONS LC -SIS MODULAR CAPACITY CHART FIXTURE NAME CAPACITY QUANTITY TOTAL 48" PERIMETER WALL UNIT 72 4 288 24" PERIMETER WALL UNIT 36 2 72 ENDCAP 15 3 45 4' GONDOLA TABLE 92 2 184 ENGAGEMENT TABLES 20 1 20 TOTAL 609 4-LCM17-A100-REV00 J` SALES AREA BACKWRAP & PERIMETER WALL MISC. FIXTUREI DIMENSIONAL FIXTURE DIMENSIONAL X DATA (NOT ALL FIXTURES MAY BE USED IN PROJECT. FOR REFERENCE AND LAYOUT PURPOSES ONLY) NAL DATA 5 O MFG./PHONE # 5'-8" ALTERNATE 7'-4" SUPP. INST. 7'-4" KIDDE / GRAINGER PARTS OF AMERICA T-4" PRO LINE #PR02-STCM BRACKET 4T307 LARSEN'S 800-633-6668 P SERES MPs,wi6 2 WALL BRACKET FOR CLASS A, B AND C FIRES I I PAPER TOWEL HOLDER - WALL MOUNTED STAPLES I ' NONE REFRACTION ROOM T GC 1 I III I ON ARM71 PAMDLPER #TO: KTWE116L 1HOLDER SIMPLEHSTAINLESSUMANSTEEL. ITTENSIEM#1809 (1 vt II T l COAT HOOK GRAINGER 1-800-GRAINGER r NONE i I'II 0835-00 0836-00 0834-00 0833-00 mboo 31,, Iy ` 0440-00 4 ^Obeo 1 15,E 0430-00 GC BRACKETS KNAPE & VOGT (OR EQUAL) HEAVY DUTY W/ LOCK NUT #KV187ANO, WHITE NONE STOOL GC GC SHELVING r -117Y 3/4" TH. X 12"D WHITE MELAMINE FINISHED ON ALL SURFACES NONE , ,,„ GC GC CEILING ACCESS PANEL ^Oboo (800) 872-5625 TR-AP024 24" X 24" ACCESS PANEL NONE r -I GC GC CABINET HANDLE DOOR BUMPER r -I 1 1/8" NAIL -ON MDL.: 49955 - HOME DEPOT EQUAL TO COLOR BACK OF HOUSE ONLY 0451-00 ♦ 0400-00 ♦ 0420-00 Jr" 3Z" SINK SK7 SINK CCD 0186-00 Lri�� t FURNITURE # 0450-00 BLOCKING GS-FNO7 STOOLS FOR SELECT TABLE 1-LCM17-A100-REVO0 EXAM ROOM 101 CLG. HT = 10'-0" A. G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, WALL CABINETS, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS. B. G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION. C. G.C. TO PROVIDE ADEQUATE BRACING, AS REQUIRED, IN WALLS TO SUPPORT WALL CABINETS AND FIXTURES. D. G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT ONLY. E. G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED DAMAGES" ON IT. F. G.C. TO REFER TO GRAPHICS STANDARD MANUAL FOR GRAPHIC MOUNTING HEIGHTS, TYPICAL. G. E = EXISTING TO REMAIN. M = EXISTING TO BE RELOCATED. F= FUTURE EQUIPMENT H. REFER TO ELEVATION SHEETS A200 -A201 FOR ACCESSIBILITY ACCESS SIGNAGE 3-LCM17-A100-REVO0 CAPACITY CALCULATIONS LC -SIS MODULAR CAPACITY CHART FIXTURE NAME CAPACITY QUANTITY TOTAL 48" PERIMETER WALL UNIT 72 4 288 24" PERIMETER WALL UNIT 36 2 72 ENDCAP 15 3 45 4' GONDOLA TABLE 92 2 184 ENGAGEMENT TABLES 20 1 20 TOTAL 609 4-LCM17-A100-REV00 J` p NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE ARCHITECTURAL SPECIFICATIONS' FINISHES GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS MISC. OTHER � ITEM / DESCRIPTION MFG./PHONE # MODEL #/COLOR ALTERNATE REMARKS SUPP. INST. FIRE EXTINGUISHER - MULTI-PURPOSE DRY CHEMICAL TYPE: UL RATED 1-A 10-B/C, 5 LB KIDDE / GRAINGER PARTS OF AMERICA (800) 323-0620 PRO LINE #PR02-STCM BRACKET 4T307 LARSEN'S 800-633-6668 P SERES MPs,wi6 2 WALL BRACKET FOR CLASS A, B AND C FIRES GC GC PAPER TOWEL HOLDER - WALL MOUNTED STAPLES (800) 333-3330 SIMPLEHUMAN QUICK LOAD PAPER TOWEL HOLDER WALL MOUNT -STAINLESS STEEL - ITEM#180969 MDL KT1024 NONE REFRACTION ROOM T GC PAPER TOWEL HOLDER - FREESTANDING STAPLES (800) 333-3330 ON ARM71 PAMDLPER #TO: KTWE116L 1HOLDER SIMPLEHSTAINLESSUMANSTEEL. ITTENSIEM#1809 NONE CONTACT LENS ROOM, OPTICAL STATION T T COAT HOOK GRAINGER 1-800-GRAINGER 10G182 POLISHED CHROME DOUBLE ROBE HOOK MODEL #O1-9402, NONE OD ROOMS; INCLUDES MOUNTING HARDWARE GC GC WALL STANDARDS KNAPE & VOGT (OR EQUAL) HEAVY DUTY STEEL STANDARD #KV85ANO (DOUBLE SLOT), WHITE NONE REFER TO ELEV. FOR SIZE; PROVIDE BLOCKING AS REQUIRED GC GC BRACKETS KNAPE & VOGT (OR EQUAL) HEAVY DUTY W/ LOCK NUT #KV187ANO, WHITE NONE STOOL GC GC SHELVING CHAIR MOVER 3/4" TH. X 12"D WHITE MELAMINE FINISHED ON ALL SURFACES NONE SHELVING RATED AT100 LBS. FASTEN SHELVES TO BRACKETS (DOUBLE SLOTTED STANDARDS) GC GC CEILING ACCESS PANEL WIND -LOCK (800) 872-5625 TR-AP024 24" X 24" ACCESS PANEL NONE RETAIL SALES AREA GC GC CABINET HANDLE DOOR BUMPER EVERBILT 1 1/8" NAIL -ON MDL.: 49955 - HOME DEPOT EQUAL TO COLOR BACK OF HOUSE ONLY GC GC 2-LCM17-A100-REVO0 EXAM ROOM 101 CLG. HT = 10'-0" A. G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, WALL CABINETS, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS. B. G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION. C. G.C. TO PROVIDE ADEQUATE BRACING, AS REQUIRED, IN WALLS TO SUPPORT WALL CABINETS AND FIXTURES. D. G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT ONLY. E. G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED DAMAGES" ON IT. F. G.C. TO REFER TO GRAPHICS STANDARD MANUAL FOR GRAPHIC MOUNTING HEIGHTS, TYPICAL. G. E = EXISTING TO REMAIN. M = EXISTING TO BE RELOCATED. F= FUTURE EQUIPMENT H. REFER TO ELEVATION SHEETS A200 -A201 FOR ACCESSIBILITY ACCESS SIGNAGE 3-LCM17-A100-REVO0 CAPACITY CALCULATIONS LC -SIS MODULAR CAPACITY CHART FIXTURE NAME CAPACITY QUANTITY TOTAL 48" PERIMETER WALL UNIT 72 4 288 24" PERIMETER WALL UNIT 36 2 72 ENDCAP 15 3 45 4' GONDOLA TABLE 92 2 184 ENGAGEMENT TABLES 20 1 20 TOTAL 609 4-LCM17-A100-REV00 J` FXT _ PLAN - KEY NOTES O 1. GRAPHIC PACKAGE ITEMS; REFER TO RESPONSIBILITY SCHEDULE ON G001 FOR RESPONSIBILITIES. REFER TO INTERIOR ELEVATIONS FOR MOUNTING DIMENSIONS AND GRAPHICS SCHEDULES THIS SHEET AS APPLICABLE. LOCATIONS ON PLAN.) 2. CCNTCR MILLWORK / GRAPI TICS ON TI IIS LINC. 3. DOCTOR'S EQUIPMENT. REFER TO RESPONSIBILITY SCHEDULE ON G001. 4. COAT HOOK AT 48" TO CENTERLINE OF HOOKS. 5. 2A-10BC FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED 6. GC 7. COORDINATE 8. G.C. 9. INSTALL STRAIGHT TO USC PERIMETER FIXTURE DIMENSIONAL DATA (TI HS PAGE) TOR PROPER DIMENSIONS FOR MILLWORK WITH TENANTS MILLWORKER. TO APPLY PAINTABLE CAULK WHERE MILLWORK COUNTERS MEETS GYP WALL LCNGTI I. BD. WALL. VERIFY ADJACENT WALL IS CLEAN, LEVEL, es—FW FIXTURES SEQUENTIALLY STARTING AT THIS POINT. GC TO AND PLUMB. 10. CL SI IELF 36/48 (2) 3/4" TI IICK x 12" DEEP WI IITE MELAMINE SI ICLVCS, TINISI ICD ON ALL SIDES, FASTENED TO G'-0" TALL WI IITC DOUBLE SLOTTED STANDARDS APJD BRACKETS AT 18"O.C. BOTTOM OT STANDARDS TO START 16" A.F.F. CFYP.) FINISH. SEE SHEET A103 FOR AND FIRST SI ICLT TO DC MOUNTED AT 48" A.F.F. 11. DOCTOR'S CERTIFICATES/ LICENSES TO BE INSTALLED AT THIS LOCATION. 12. FUTURE EQUIPMENT (SHOWN FOR TENANT INFORMATION ONLY) 13. REFER TO ELECTRIC SHEETS FOR ELECTRICAL / DATA FLOOR BOX LOCATIONS. 14. SEE ELEVATION SHEET(S) FOR LOCATION OF START AND END POINTS OF WALL FINISH SCHEDULE. 15. SANITARY 16. HIPPA 17. LEASE 18. ELECTRICAL PUMP. REFER TO PLUMBING AND ELECTRIC SI ICCTS TOR APPLICABLE / OPTICIANS LICENSE TO BE INSTALLED AT THIS LOCATION. LINE PANEL. REFER TO ENGINEER DRAWINGS FOR MORE INFORMATION. INFORMATION. RECEIVED CITY OF TUKWILA JUN 28 2017 PERMIT CENTER I REVIEWED FOR RODE COMPLIANCE APPROVED 1 JUN 29 2011 • City of Tukwila BUILDING DIVISION 1 ... 5-LCM17-A100-REVO0 6 FIXTURE' FLOOR PLAN - SCHEDULE EQUIPMENT # DESCRIPTION BLOCKING EQ6 LENSOMETER (MANUAL) EQ6A LENSOMETER (AUTO) EQ8C FRAME TRACER EQ21 EYE NET STATION EQ22A FRAME WARMER (HOT AIR) EQ100A SINGLE POWER TABLE EQ100C TRIPLE POWER TABLE EQ101 TONOMETER EQ102 AUTO -REFRACTOMETER EQ105C FIELDS TESTER EQ108 PATIENT CHAIR EQ109B REFRACTION STAND EQ112 STOOL EQ118C CHAIR MOVER EQ119 LCD SCREEN BLOCKING PROVIDED -AND INSTALLED BY GC. EQ120 OPTOS EQ121 OPTOS TABLE EQ122 REFRACTION ROOM CHAIR EQ122C REFRACTION ROOM CHAIR (CALIFORNIA) CHART HOLDER CHART HOLDER (WALL MOUNTED) 3LOCKING PROVIDED AND INSTALLED BY GC. SK3 SINK SK7 SINK FURNITURE # DESCRIPTION BLOCKING GS-FNO7 STOOLS FOR SELECT TABLE GS-FNO4 LOUNGE CHAIR GS-FN08(A)(B)(C) ADJ. TASK CHAIR("A"-HARD SURF. "B" -CARPET "C -CALIFORNIA) GS-FNO9 SIDE CHAIR GS-FNO9C SIDE CHAIR (CALIFORNIA STORES) GS-FN02(A)(B)(C) ADJ. STOOL ("A" -HARD SURF. "B" -CARPET "C -CALIFORNIA) GS-FNO5 SIDE TABLE (W/ GS-FNO4 CHAIRS) MILLWORK GLOBAL # MILLWORK MODULAR # DESCRIPTION BLOCKING GS-CW20 0801-00 CASHWRAP, LC SIS GS-CW2OW - CASHWRAP, LC SIS (REQUIRES WIRING BY GC) GS-LF10 - 27" (H) JOJO GS-LF11 0300-00 35"(H)JOJO GS-LF13 0920-00 FRONT DOOR FOCAL GS-LF20 0303-00 27" (H) ENGAGEMENT TABLE GS-LF21 - 33" (H) ENGAGEMENT TABLE GS-LF22 0302-00 ENGAGEMENT TABLE 2 GS-PW40 1800-00 CASHDESK OD (3) MODULES GS-PW41 1830-00 BACKWRAP OD (4) 55" MONITORS GS-LF42 - SELECT BAR GS-PW43 1801-00 CASHDESK OD (2) MODULES GS-LF50 0321-00 CAPAUIY FIXTURE ENDCAP GS-LF51 0320-00 CAPACITY FIXTURE, 2 -BAY GS-LF52 - CAPACITY FIXTURE, 3 -BAY GS-LF53 0322-00 GONDOLA MONITOR GS-LF70 0307-00 FITTING/SELECT TABLE GS-LF70A 0306-00 FlI IING-SELECT TABLE GS-LF7OW - FITTING/SELECT TABLE (REQUIRES WIRING BY GO GS-LF71 0308-00 FITTING/CASHWRAP GS-LF71W - FITTING/CASHWRAP (REQUIRES WIRING BY GC) GS-LF75B 0310-00 (2) MODULAR SELECT TABLE GS-LF75C 0311-00 (3) MODULAR SELECT TABLE GS-PW76A 0830-00 BACKWRAP (4) 55" MONITORS GS-LF80 0309-00 WELCOME TABLE GS-LF90 - COLUMN PANEL, WITH BRAND MENU GS-LF91 - SERVICE TOTEM, FLOOR FIXTURE GS-LF92 - EASEL FIXTURE GS-LF93 - COLUMN PANEL WITH MIRROR GS-PWO1 (L) 0440-00 3" PERIMETER FIN ("L"=LEFT) )3LOMSTG PRO OVIDED Y GC GS-PW01 (C) 0430-00 3" PERIMETER FIN ("C"=CENTER) GS-PW01 (R) 0440-00 3" PERIMETER FIN ("R"=RIGHT) GS-PWO1A (L) 0440-00 3 1/8" PERIMETER FIN ("L"=LEFT) GS-PWO1A (C) 0430-00 3 1/8" PERIMETER FIN ("C"=CENTER) GS-PWO1A (R) 0440-00 3 1/8" PERIMETER FIN ("R"=RIGHT) GS-PW10 0400-00 48" (W) PERIMETER WALL UNIT GS-PW11 0420-00 25" (W) PERIMETER WALL UNIT GS-PW30 0451-00 18" (W) MIRROR CABINET WITH STORAGE GS-PW31 0450-00 12" (W) MIRROR CABINET WITH STORAGE GS-PW60 0831-00 BACKWRAP FEATURE GS-PW60_55 0831-00 BACKWRAP W/ 55" DIGITAL MONITOR GS-PW60 75 0834-00 BACKWRAP W/ 75" DIGITAL MONITOR GS-PW61 0832-00 BACKWRAP FEATURE WITH SIGNAGE GS-PW61_55 0832-00 BACKWRAP FEATURE W/ SIGNAGE & 55" DIGITAL MONITOR GS-PW61_75 0835-00 BACKWRAP FEATURE W/ SIGNAGE & 75" DIGITAL MONITOR GS-PW62 0833-00 BACKWRAP FEATURE WITH WOOD FRAME GS-PW62_55 0833-00 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 55" DIGITAL MONITOR GS-PW62_75 0836-00 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 75" DIGITAL MONITOR GS-PW80 - FILLER WITH MIRROR, NO STORAGE GS-PW81 0186-00 PORTAL VERTICAL MODULE GS-PW82 0186-00 PORTAL HORIZONTAL MODULE GS-PW83 - WOOD FIN VERTICAL GS-PW84 0460-00 CORNER FILLER GS-PW91 1811-00 SERVICE TOTEM, WALL MOUNTED GS-PW93 - MIRROR, OVERALL SIZE MATCHES LF90/93 GS-PW94 1844-00 FRAME LEDGE, 26" W GS-PW95 1846-00 FRAME LEDGE, 48" W BOH-UP24 - UPPER CABINET GS-BOH01(L) 1842-00 WORK COUNTER FOR SIS (LEFT) GS-BOHO1(R) 1843-00 WORK COUNTER FOR SIS (RIGHT) GS-CL02(L) 1860-00 SINK BASE FOR SIS (LEFT) GS-CL02(R) 1861-00 SINK BASE FOR 515 (RIGHT) SE-CLO3 1863-00 CONTACT LENS STORAGE SE-0D01(L) 1853-00 DOCTORS DESK (LEFT) v SE-ODO1(R) 1854-00 DOCTORS DESK (RIGHT) SE -0D02 1855-00 SINK BASE SE -0D03 1856-00 SINK CABINET ABOVE GRAPHICS # DESCRIPTION BLOCKING LQ -GH -30 OD SNAP FRAMES LCM-DO-CS LCM-EE-CS EYE EXAMS CABINET SIGN LCM-FW-CS FOCAL WALL CABINET SIGN LCM-FW-CS.1 FOCAL WALL CABINET SIGN FOR 75" DIGITAL MONITOR BACK WRAP LCM-GH-16 DOCTOR'S NAME SLAT SIGN LCM-GR-32 ROOM ID SIGNS LCM-MW-CS MAIN WALL CABINET SIGN LCM-MW-CS.1 MAIN WALL CABINET SIGN SE -GH -23 CER IC SNAP MES PiL Ald , M17-A100-REV00 JIHI DESIGN & CONSTRUCTION MANAGEMENT: RE O 4000 Luxottica Place, Masan, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 0+1 (513) 765-6000 0 +1 (516) 393-2484 Stoore 41E8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for. (11 CD uj O d� F= (3 O L)0 0c O 0 V1 N V Oa_ O 5) LLJ Qo Macy's Store Number: Revisions: Mark Date By A4/10/17 ST CUENT COMMENTS A6/02/2017 SNT CUENT COMMENTS A6/15/2017 SEV CITY COMMENTS A A Architect of Record MATTHEW D. WITTMER AIA LEED-AP P 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑ Client Review ❑DOB Permit ❑DOB Permit - Re -Submit ❑ LL Approval ❑ Bid ® Construction Title FIXTURE - FLOOR PLAN Date Sheet 04/06/2017 Drawn By 1 Checked By A100 DAF MACY'S HALLWAY 104 CLG. HT = 10'-0" 3'-0" 4'-12" R.O. (HOLD) 4'-0" F.O. (HOLD) CONTACT LENS 104 3'-0" 41. G LCM-EE-CS CLG. HT.= 10'-0" CONSTRUCTION - FLOOR PLAN ISCALE: 1/4" = 1'-0' 5'-0" i 26 0 m 0 1'-11" 7'-22" AD/EX 0 6'-021 4 6.1 CV 0 8'-5" +/- 0 if 0 RETAIL SALES AREA -.go 04 -\ 0 0 7 0 O rn 8'-0" 0 1 OPTICAL STATION 103 CLG. HT = 10'-0" METAL STUD WALL WITH PAINTED GYPSUM BOARD BOTH SIDES METAL FRAME DOOR JAMB DOOR: REFER DOOR SCHEDULE INTERIOR DOOR O METAL STUD WALL WITH PAINTED GYPSUM BOARD BOTH SIDES rn 3/4" HARDWOOD PAINTED CASED OPENING O 2-LCM17-A101-REV 00 PRETEST 102 CLG. HT = 10'-0" EXAM ROOM 101 CLG. HT.= 10'-0" 100 CLG. HT = VARIES 5 DOOR HARD ORE ...NOTEALL SPECS MAY NOTBE USED IN EVERY STORE VV ARE SCH EDULE GENERAL NOTE: FOLLOW ALL MANUFACTURERS '�•INSTALLATION AND MAINTENANCE INSTRUCTIONS DESCRIPTION MFR. MDL # / COLOR ALTERNATE REMARKS CONTACT "CLASSROOM" BEST ACCESS SYSTEMS 93K 7 R 15 D STK FINISH - US26D SCHLAGE KEY OPERATED ON OUTSIDE ONLY BEST ACCESS (317) 849-2250 INTERIOR LOCK CORES BEST ACCESS SYSTEMS 9K SERIES NONE CONSTRUCTION CORE PROVIDED AT PUNCH BEST ACCESS (317) 849-2250 BUTT HINGES (1-1/2 PAIR PER DOOR) STANLEY HARDWARE FBB-179, 4-1/2" x 4-1/2" FINISH - US26D HAGER HINGE CO TYPE STANLEY HARDWARE (800) 622-4393 WALL BUMPERS NES #407-1/2" CONCAVE ALUM SILVER BROOKUNE #1326 -CV CONCAVE REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS. IVES (877) 671-7011 FLOOR STOPS NES #436 ALUM SILVER BROOKLINE #1330A �/ \/ CASED OPENING P104 (PAINTED/) SOLID CORE WOOD DOORS / PL -LAM DOORS COMMERCIAL DOOR & HARDWARE SEE DOOR SCHEDULE SUBSTRATE ADHESIVE TO HAVE A VOC LIMIT OF 30 g/L LESS WATER NO ADDED UREA- FORMALDEHYDE RESINS FSC WOOD COMMERCIAL DOOR (865) 429-8980 HOLLOW METAL DOORS & FRAMES COMMERCIAL DOOR & HARDWARE SEE DOOR SCHEDULE WALL CONSTRUCTION AND RATING. PREP WALL TO RECCNC NCW Q -0 \ \ \ \ PANEL ACUDOR #Z91818SCWH EQUAL FINISH X 18"A CESACCS PANELS PANEL DES.PAINPER WALL 1ACCESS ACCESS RESIDES. HOME DEPOT 5-LCM17-A101-REV 00 PRETEST 102 CLG. HT = 10'-0" EXAM ROOM 101 CLG. HT.= 10'-0" 100 CLG. HT = VARIES 5 DOOR TYPES W LL TYPE LEGEND A NEW NON -RATED INTERIOR PARTITION REFER TO DETAIL 2/.444149 FOR CONSTRUCTION B NEW NON -RATED INTERIOR PARTITION REFER TO DETAIL 4 FOR CONSTRUCTION 4 •• NEW NON -RATED FURR INTERIOR PARTITION • a II k , Or 0', !..../t. D NEW NON -RATED INTERIOR PARTITION REFER TO DETAIL « -'' FOR CONSTRUCTION 6' DOOR TYPES SOLID CORE WOOD DOOR (FLUSH), DOOR PAINTED PL105, FRAME PAINTED P104. SEE PLAN FOR DIRECTION OF SWING ROOM NAME MARK DOORS FRAMES HARDWARE ♦ ♦ - FINISH LABEL HEAD JAMB DESCRIPTION CLOSER THRESHOLD STOP KICK 0 WIDTH HEIGHT \\ TYPE T102 COLOR / o GLAZING LABEL REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS. REVIEWED FOR CODE COMPLIANCE APPROVED ;' ►JUN 2 9 2017 j. •' City of Tukwila BUILDING DIVISION 4'-0" i O p A �/ \/ CASED OPENING P104 (PAINTED/) RECEPTACLE, COORDINATE W ITT I ELECTRICAL DRAWING.). 12. m is N a, A 4'-1 iR.O.VOLD WALL CONSTRUCTION AND RATING. PREP WALL TO RECCNC NCW Q -0 \ \ \ \ FINISI IES. CASED OPENING CASED OPENING 101C 4'-0" 9'-3 5/8" I 4'-0" F.O. C 15. ••:. •. • • •: ; o $'. . - :.. . ,, ,, - •;•°:. ; - i ♦ . 16. ` 0 17. i ROVIDE AND INSTALL FLOOR MOUNTED SEWAGE EJECTION PUMPS. SCC f'LUMDING DRAWINGS TOR SPECIFICATIONS . FINISHED CASED OPENING MATERIALS BY G.C. O WHEN CASED OPENING ABUTTS WALL COVERING OR PAINT 102 3-LCM17-A101-REV00 6' DOOR SCHEDULE KEYED ROOM NAME MARK DOORS FRAMES HARDWARE REMARKS DOOR SIZE DOOR DESCRIPTION MATERIAL FINISH LABEL HEAD JAMB DESCRIPTION CLOSER THRESHOLD STOP KICK WIDTH HEIGHT THICK TYPE CONSTRUCT COLOR FINISH GLAZING LABEL REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS. 101A 4'-0" 9'-4 5/8" GYP. BD. BULKHEAD ABOVE. A RECESSED RECEPTACLE, COORDINATE W ITT I ELECTRICAL DRAWING.). 12. WRAP COLUMNS AS INDICATED. 1 INFILL WALL AS RCQUIRCD. MATCI I ADJACENT WALL CONSTRUCTION AND RATING. PREP WALL TO RECCNC NCW FINISI IES. CASED OPENING CASED OPENING 101C 4'-0" 9'-3 5/8" C 15. ••:. •. • • •: ; o $'. . - :.. . ,, ,, - •;•°:. ; - I EVCL 4 FINISI I TYP). 16. PROVIDE AND INSTALL NEW PARTITIONS AS DIMENSIONED. PROVIDE AND INSTALL ALL DOORS AND/OR CASED OPENINGS AS SPECIFIED. 17. i ROVIDE AND INSTALL FLOOR MOUNTED SEWAGE EJECTION PUMPS. SCC f'LUMDING DRAWINGS TOR SPECIFICATIONS . FINISHED CASED OPENING MATERIALS BY G.C. EXAM ROOM 102 3'-0" 6'-8" 1 3/4" B SOLID CORE - PL105 NONE NONE HM P104 NONE 2 LEVER/CLASS-RM NO NO FLR NO FACE OF NEW CONSTRUCTION. TO BE FLUSH WITH FACE OF EXISTING CONSTRUCTION. 24. 103 AS REQ. AS REQ. 13/4" D SOLID CORE GYP BOARD AS REQUIRED. FINAL WALL TO HAVE LEVEL 4 FINISH. IF NOT GYPSUM BOARD EXISTS (IF BARE STUDS), REMARK NONE NONE HM REMARK NONE 2 LEVER/CLASS-RM NO NO FLR YES DOOR HANDLE MFG.: TRILOGY MDL NO.: T2 DL 2700IC/26D HINGES - MFG.: STANLEY MDL NO: FB -179 (3 PER DOOR) FLUSH BOLT WHERE REQUIRED MDL. NO.: NES 458B26D GC TO VERIFY W MACY'S ON-SITE OPERATIONS FOR DOOR FINISH TO MATCH MACY'S 30. G.C. TO SUPPLY AND INSTALL A PERMANENTLY MOUNTED SIGN ON DOOR THAT SAYS, NOT AN EXIT. 31. EXISTING VOID SPACE NO ACCESS AND NO WORK THIS AREA. 2. EXISTTIING EGRESS STAIR FOR UPPER LEVEL. NO WORKS A•EA. 1-LCM17-A101-REV 00 6-LCM17-A101-REV 00 1 KEYED NOTES O 1. COAT HOOK PROVIDED AND INSTALLED BY GC. MOUNT AT 48" A.F.F. INTERIOR SIDE OF REFRACTION ROOM DOOR. 2. SCC ELEVATIONS TOR LOCATION Of WALL TILE FINISI L 3. SEE ELEVATIONS FOR BASEBOARD LOCATION AND STYLE. 4. NEW STUB -UP CONDUITS, REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATION FOR UTILITIES AND FREESTANDING MILLWORK AND TRENCHING. 5. GC TO PROVIDE AND INSTALL CORNER GUARDS AT ALL BACK OF HOUSE OUTSIDE WALL CORNERS. SEE FINISH SCHEDULE FOR MAKE AND MODEL. 6. PANEL. GC TO PROVIDE &INSTALL ACCCSS P LL. 7. i LISTING PARTITION. G.C. TO f ATCI I/REPAIR AS RCQUIRCD TO MAINTAIN RCQUIRCD RRC RATING. 8. REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS. 9. NEW ELECTRICAL DISTRIBUTION EQUIPMENT, REFER TO ELECTRICAL DRAWINGS. 10. GYP. BD. BULKHEAD ABOVE. 11. RECESSED RECEPTACLE, COORDINATE W ITT I ELECTRICAL DRAWING.). 12. WRAP COLUMNS AS INDICATED. 13. INFILL WALL AS RCQUIRCD. MATCI I ADJACENT WALL CONSTRUCTION AND RATING. PREP WALL TO RECCNC NCW FINISI IES. 14. EXISTING PARTITIONS AND COLUMN ENCLOSURES WITI I IN LCASC ARCA TO DC I'ATCI ICD AND REPAIRED UPON ALL NCW WORK TO A LEVEL 4 FINISI I. (TYP) 15. ••:. •. • • •: ; o $'. . - :.. . ,, ,, - •;•°:. ; - I EVCL 4 FINISI I TYP). 16. PROVIDE AND INSTALL NEW PARTITIONS AS DIMENSIONED. PROVIDE AND INSTALL ALL DOORS AND/OR CASED OPENINGS AS SPECIFIED. 17. i ROVIDE AND INSTALL FLOOR MOUNTED SEWAGE EJECTION PUMPS. SCC f'LUMDING DRAWINGS TOR SPECIFICATIONS . 18. PROVIDE 14" X 24" I LUST I ACCCSS PANELS AT SANITARY PUMP LOCATIONS. G.C. TO PAINT PANEL TO MATCI I SURROUNDING WALL 19. PROVIDE 18" X 18" FLUSI I ACCESS PANELS AT SANITARY PUMP LOCATIONS. G.C. TO PAINT PANEL TO MATCI I 20. LOCATION OF HAND WASH SINKS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS, AND WATER HEATER MOUNTING OF AND SPECIFICATIONS. 21. 8'-0" X 7'-0" NON -CASED OPENING. WRAP GYP. BOARD THROUGH OPENING. 22. LEASE LINE 23. FACE OF NEW CONSTRUCTION. TO BE FLUSH WITH FACE OF EXISTING CONSTRUCTION. 24. EXISTING MACY'S SPRINKLER ROOM. NO WORK THIS AREA. 25. ENCLOSE COLUMN WITH 5/8" TYP X GYP BOARD. HOLD GYP TIGHT TO COLUMN. 26. GC TO PATCH AND REPAIR WALL AS REQUIRED TO MAINTAIN 2 HOUR RATING. SUPPLY AND INSTALL NEW TYPE 'X' GYP BOARD AS REQUIRED. FINAL WALL TO HAVE LEVEL 4 FINISH. IF NOT GYPSUM BOARD EXISTS (IF BARE STUDS), NOTIFY NEXTORE PROJECT MANAGER IMMEDIATELY. 27. NEW ACCESS HALLWAY THROUGH MACY'S ELECTRICAL ROOM. PROVIDE ACCESS TO ELECTRICAL ROOM AT ALL TIMES. 03 28. C. ' 0 P`OVIPE H`'RIZ• TA ANi VE• CA FIR BL•CKI @ 0' 0.. MA AS "EQ RED : T BUI DIN CODE 7182.2. 29. NO COMBUSTIBLE MATERIALS SHALL BE PERMITTED WITHIN THE VOID SPACE. 30. G.C. TO SUPPLY AND INSTALL A PERMANENTLY MOUNTED SIGN ON DOOR THAT SAYS, NOT AN EXIT. 31. EXISTING VOID SPACE NO ACCESS AND NO WORK THIS AREA. 2. EXISTTIING EGRESS STAIR FOR UPPER LEVEL. NO WORKS A•EA. 1-LCM17-A101-REV 00 A. GC TO MAINTAIN ALL DIMENSIONS AS SPECIFIED. NOTIFY NEXTORE PROJECT MANAGER OF ANY DISCREPANCIES OF HOLD DIMENSIONS. B. GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS REQUIRED AT THE PERIMETER TO PRODUCE A FLUSH CONDITION BETWEEN THE LENSCRAFTERS FLOOR AREA AND THE EXISTING AREA FLOORING SURROUNDING. C. GC IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. GC IS ALSO RESPONSIBLE FOR ALL FINISH WALL MATERIALS BEHIND AND UNDER ALL MILLWORK. D. GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL SHELVING AND CABINETS. ANCHOR BLOCKING W/ SCREWS AT TOP MIDDLE AND BOTTOM (NO SILICONE). REFER TO DWG. A200 & A201 AND MILLWORK SHOP DRAWINGS FOR MOUNTING HEIGHTS. E. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT WITH LANDLORD'S ON-SITE REPRESENTATIVE. F. REFER TO SPECIFICATIONS (UNDER SEPARATE COVER) CONSTRUCTION CRITERIA MANUAL G. NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT MANAGER FOR REVIEW AND APPROVAL. H. ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO BE FOLLOWED BY GENERAL CONTRACTOR ON THIS PROJECT. I. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON AS CONTRACTS ARE AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT INFORMATION. J. GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE DELAY OF ORDERING SPECIFIED PRODUCTS. K. ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE PROJECT MANAGER FOR DOCUMENT CLARIFICATION. L. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED & SUPERVISED BY GC. M. N. 0. ALL DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS NOTED OTHERWISE ON PLANS. ALL GYP. WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP. TO BE LEVEL 5 FINISH. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. RECEIVED CITY OF TUKWILA JUN 28 2011 DESIGN & CONSTRUCTION MANAGEMENT: RE 0 4000 Luxottica Place, Masco, OH 45040 0 6 Creamery Brook, East Granby, CT06026 O +1 (513) 765-6000 0+1 (516) 393-2484 S re 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: us) W 10= U tin z w 0_O 0 In O 1E 0 c 0 If) co a) coU O E.. !O - • n ▪ Q Q 0 U 0 x J Macy's Store Number: Revisions: Mark Date By L \ 4/10/17 ST CLIENT COMMENTS / 1 6/02/2017 SNT CLIENT COMMENTS ' \ 6/15/2017 SEV CITY COMMENTS A A1 Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 6/.6/24%7 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: R 0Client Review ❑DOB Permit ❑DOB Permit - Re -Submit 0 LL Approval D Bid II Construction Title CONSTRUCTION FLOOR PLAN Date 04/06/2017 Drawn By Checked By DAF Sheet A101 • • • • :rt' • Irtii■■■t■■i■ ■ ■ P. ■f. • • MIN imenin • ■ 0 1 CONTACT LENS 104 8T -S 6T -S LCM-EE CLG. HT = 10'-0" /\ REFLECTED CEILING PLAN \ / SCALE: 1/4' =I-0' AD • CS LTL T 0 L AD / P 77 /. U WTL fL TL TL L LTL TI ■ ELT 4T -S 12T -S L TY TY L' l TL TL TL TL • RETAIL SALES AREA nn summe AD 7' AD 411 100 CLG. HT = VARIES OPTICAL STATION 103 CLG. HT = 10'-0" PRETEST 102 CLG. HT.= 10'-0" EXAM ROOM 101 CLG. HT = 10'-0" A. EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. B. ALL NIGHT -LIGHT (NL) LUMINARES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING C. IT SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE G.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, G.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. F. G.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINARES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. G.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, G.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE. G. G.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. H. G.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. L CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED. J. DOWN LIGHTS SHALL BE CENTERED IN TILE UNLESS OTHERWISE NOTED. 1-LCM17-A102-REV 00 3 KEYED NOTES O 1. EXISTING CEILING IN THE RETAIL AREA IS THE EXISTING MACY'S CEILING TO REMAIN, PATCH GRID INTO NEW WORK AND REPLACE ANY DAMAGED OR STAINED TILES WITH NEW TO MATCH EXISTING.. 2. EXISTING GYP. BD. CEILING IN THE RETAIL AREA. EXISTING MACY'S CEILING TO REMAIN. 3. SEE SHEET A101 CONSTRUCTION FLOOR PLAN AND ELEVATIONS FOR BULKHEAD HEIGHT 4. PROVIDE AND INSTALL NEW 2X2 ACOUSTICAL CEILING IN THE OD AREA. TO BE CENTERED IN ROOM. SEE FINISH SCHEDULE SHEET A103. 5. EXISTING LIGHTING IN THE RETAIL AREA IS THE EXISTING MACY'S LIGHTING TO REMAIN. CLEAN AND RELAMP. 6. INSTALL PROVIDED 2 X 2 FLUORESCENT LIGHTING TYPE "AD" AND "AD -EM". 7. INSTALL PROVIDED SECTIONS OF TRACK "XT -S" AND LIGHTING FIXTURES "TL" AS SHOWN. "X2". 8. INSTALL PROVIDED EXIT LIGI ITIPJG TYPE 9. EXISTING HVAC DIFFUSERS IN THE RETAIL AREA ARE EXISTING MACY'S TO REMAIN, CLEAN. 10. NEW HVAC DIFFUSERS IN OD ROOMS. SEE MECHANICAL 11. E-3CISTING CMCRGCPJCY LIGI (TING IN TI IC RETAIL ARCA TO REMAIN. FIELD VERIFY FIXTURES ON EMERGENCY GENERATOR 12. EXISTING DESCRIPTION SPEAKERS, SECURITY CAMERAS, TO REMAIN. REVIEWED FOR 13. SPRINKLER I ICADS rOR REFERENCE ONLY WI ICN SI TOWN COD COMPLIANCE 14. LEASE LINE I,... APPROVED 15. OUTLINE OF PERIMETER FIXTURES epi q7 16. INSTALL MONOPOINT FIXTURE OVER FLOOR FIXTURE AS SHOWN. ' 1 JUN 2 9 2.1 j 17. RELOCATED 2 X 2 FLUORESCENT LIGHT. 18. EXISTING GYP. BOARD SOFFIT @ 10'-71/4" TO REMAIN. 06% of Tukwila BUILDING DIVISION 2-LCM17-A102-REV 00 3 LIGHTING SCHEDULE SPRINKLER SYMBOL TYPE DESCRIPTION DESCRIPTION CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. DESIGN STANDARDS: - HARD CEILING AND CEILING TILE AT RETAIL AREA / STOREFRONT: WHITE CONCEALED HEADS; RELIABLE MODEL 'G-4'; TYCO 'RF -11' - CEILING TILE AT OD, AND LENS PROCESS: RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS; RELIABLE MODEL "G -F1'; TYCO TY -L' - CEILING TILE AT LOUNGE, OFFICE, AND BACK OF HOUSE: WHITE PENDANT HEADS WITH WHITE TRIM RINGS; AD RECESSED 2X2 LED TROFFER SEE ELEC. SHEETS FOR MFG, SPECS ETC. (TYP. ALL LIGHTS IN SCHEDULE) AD CEILING SYMBOLS AD- EM RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY BACKUP. 24"X24" AD -EM X2 X2 RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING OR WALL MOUNTING RED LED INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC OR CHICAGO CONFIRM WITH MANUF). PROVIDE CURRENT LIMITER WHERE REQUIRED. SPRINKLER HEAD RETURN TL2 TL2 FLUSH MONOPOINT FITTING, WHITE GIMBAL STYLE LAMP -HOLDER, WHITE 2T 5-LCM17-A102-REV 00 2T -S 2 FT LONG, SINGLE CIRCUI1 WHITE TRACK TL TL GIMBAL STYLE LAMP -HOLDER, WHITE 4T -S 4T -S 4 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL TL GIMBAL STYLE LAMP -HOLDER, WHITE 6r 6T -S 6 FT LONG, SINGLE CIRCUIT WHITE TRACK TL TL GIMBAL STYLE LAMP -HOLDER, WHITE 8T 8T -S 8 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL TL GIMBAL STYLE LAMP -HOLDER, WHITE .2T -s 12T -S 12 FT LONG, SINGLE CIRCUIT, WHITE TRACK 8 TL TL GIMBAL STYLE LAMP -HOLDER, WHITE 3-LCM17-A102-REV 00 4 SPRINKLER SYSTEM' NOTES OD AREA ONLY FOR NEW FIRE SPRINKLER SYSTEM: CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE CONTRACTOR SHALL HAVE DRAWINGS, SHOP DRAWINGS, APPLICATIONS AND SUBMITTALS PREPARED BY A PROPERLY LICENSED PROFESSIONAL, WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS, INSURANCE ASSOCIATIONS AND RATING BUREAUS AND SHALL INCLUDE ALL PERMITS, TESTS, SHUT DOWN FEES AND CERTIFICATIONS TO PROVIDE A COMPLETE IN PLACE SYSTEM. FOR EXISTING FIRE SPRINKLER SYSTEM: CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. DESIGN STANDARDS: - HARD CEILING AND CEILING TILE AT RETAIL AREA / STOREFRONT: WHITE CONCEALED HEADS; RELIABLE MODEL 'G-4'; TYCO 'RF -11' - CEILING TILE AT OD, AND LENS PROCESS: RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS; RELIABLE MODEL "G -F1'; TYCO TY -L' - CEILING TILE AT LOUNGE, OFFICE, AND BACK OF HOUSE: WHITE PENDANT HEADS WITH WHITE TRIM RINGS; RELIABLE MODEL "G"; 'TY -L' 4-LCM17-A102-REV 00 CEILING SYMBOLS 24"X24" SUPPLY ___6_,„,--12"X24" RETURN SPRINKLER HEAD RETURN SA HVAC AIR DEVICES SHOWN FOR REFERENCE AND COORDINATION. REFER TO MECHANICAL PLANS FOR MORE INFO. 5-LCM17-A102-REV 00 SYMBOL TYPE MANUFACTURER PART -NUMBER INPUT WATTS LAMP QTY LAMP TYPE DESCRIPTION MOUNTING CEILING TYPE 2 X 2 / 9 CELL PARABOLIC LIGHT FIXTURE WITH (2) 28 WATT U -BENT FLUORESCENT LAMPS RECESSED ADJUSTABLE DOWN LIGHTING WITH TWIN TUBE COMPACT FLUORESCENT LAMPS EXISTING TRACK LIGHTING RECEIVED CITY F TUKWILA MA 18 2017 EXISTING WALL WASH LIGHTING PERMIT CENTER ( EXISTING V:IT' N E WALL SH LIG < : • G 4.00. 6-LCM17-A102-REV 00 DESIGN & CONSTRUCTION MANAGEMENT: RE 0 4000 Luxottica Place, Mason, 001145040 0 6 Creamery Brook, East Granby, CT 06026 • +1 (513) 765-6000 0 +1 (516) 393-2484 Store 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: �o O imum co s 0 • O x O 0 tll 4-- CO O Ca_ 3 ij Q O d - Macy's Store Number: Revisions: Mark Date By A A A A A1 Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: ®Client Review ®DOB Permit ❑ DOB Permit - Re -Submit ® LL Approval ® Bid ® Construction Title REFLECTED CEILING PLAN Date 04/06/2017 Drawn By SEV Checked By DAF Sheet A102 I. a ■ a sir ■ I- ti l(1 Q 1111111111111111111111 ■ s PMS CONTACT LENS 104 TS -4 I 9/A500 17 13) RETAIL SALES AREA T102 ECM -EE=C P114 CLG. HT = 10'-0" PT108 WB102 W P101 P104 W WC105 • TS -4 o 0 9/A500 • -c t— U 100 CLG. HT = VARIES WRAP WALLCOVERING INTO CORNER PT108 WB102 W P101 P104 OPTICAL STATION 103 CLG. HT.= 10'-0" FINISH PLAN SCALE: 1/4" = 1'-0' PT108 WB102 W P101 P104 PRETEST 102 EXAM ROOM 101 CLG. HT = 10'-0" CLG. HT = 10'-0" 1 FINISH SYMBOL KEY MATERIAL ©®= GED. FLOOR BASE ®® iniii= G = WALL TRIM = CEILING (SEE RCP FOR LOCATION) 26 - 75 1-LCM 00-A103-REV00 PT108 WB102 W P101 P104 2 INTERIOR MATERIALS FIRE RATINGS MATERIAL FLAME SPREAD SMOKE DENSITY PLASTIC LAMINATE 80 (BONDED) 95 (BONDED) CARPET 26 - 75 450 OR LESS VINYL TILE 0.45 450 OR LESS LAY -IN CEILING 25 10 FRP 150 245 VINYL BASE 0.45 450 OR LESS 4-LCM17-A103-REV 00 PT108 WB102 W P101 P104 2 SH SCHED FINIULE KEYED NOTES 0 1. DESCRIPTION LINC OF PARTITION ABOVE (SI TOWN DASI ICD 2. REMARKS NO TRANSITION STRIP AT PORCELAIN TILL. TILE TO BUTT UP TO MILLWORK. FINISHES WALLS COORDINATE STOPPING POINT or PORCELAIN TILE WTTI I TENANT'S P101 PAINT (EGGSHELL) (EXTRA WHITE) MILLWORKCR. 3. G.C. TO PATCH AND REPAIR EXISTING CONCRETE AS REQUIRED PER NEXTORE INTERIOR WALLS AND SOFFITS PROJECT MANAGER'S APPROVAL. PREPARE CONCRETE AS REQUIRED FOR P104 NEW FLOOR FINISH. ENTIRE LEASED SPACE. 4. MACY'S INTERIOR ACRYLIC LATEX EXTRA WHITE, SW7006 FLOOR TILE. GC TO VERIFY W PM FOR SUPPLY AND INSTALL. TO PAINT REMAIN. 5. SHERWIN WILLIAMS GC TO WRAP DASC AND WALLCOVCRIPJG AROUND WALL CORNER &INTO 2" SW7066, GRAY MATTERS ACCENT WALL PAINT - OD AREA QUIRK. PAINT RCVCAL P117. 6. REFER TO INTERIOR ELEVATIONS FOR EXTENT OF WALLCOVERING. 7. WALL BASE SUPPLIED AND INSTALLED BY G.C. SEE DETAIL 3, SHEET A500. 8. G.C. TO INSTALL CORNER GUARD, CG -100, REFER TO THIS SHEET FOR WALLCOVERING SPECIFICATION. 9. WOLF GORDON INC. EXISTING MIRRORED COLUMNS WIll 14" DASC TO RCCCNC WD102. 10. WIDTH OF T102 MAY VARY DUE TO TRANSITION TO B.O.H.. MAINTAIN 4" WALLCOVERING EACH SIDE OF GYP. AT OPENING. 11. START TILE LAYOUT W HALF CARPET TILE AT TRANSITION. TRANSITION TO MIKE THOMPSON, 614-551-7928 OCCUR UNDER DOOR SIDE @ DOOR STOP. 12. NOTE DIRECTION OF CARPET TILE 13. LEASE LINE 14. G.C. TO MATCH WALL FINISH WITH EXISTING MACY'S FINISHES. COORDINATE H /8" TOP CHCRWOOD BASE W/ 3/AMMPAINTED FER W WITH MACY'S OPERATIONS MANAGER. 15. NEW MACY'S CORRIDOR. PAINT WALLS MACY'S WHITE. 16. EXISTING MACY'S SEALED CONRETE TO REMAIN. 17. EXISTING SAWCUT IN SLAB TO REMAIN. FINISH - P104 2-LCM 17-A103-REV00 A. G.C. IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS REQUIRED TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE LEASE LINE AND THE EXISTING MALL FLOORING. B. G.C. IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. G.C. IS ALSO RESPONSIBLE FOR ALL FINISH MATERIALS BEHIND AND UNDER ALL MILLWORK. C. REFER TO ARCHITECTURAL SPECIFICATIONS / FINISHES SCHEDULE THIS SHEET & REFER TO GENERAL NOTES ON SHEET G100 D. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED AND SUPERVISED BY G.C. E. REFER TO DOOR SCHEDULE FOR DOOR FINISHES. F. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. 3-LCM17-A103-REV 00 1 1 UI' DESIGN & CONSTRUCTION MANAGEMENT: RE ® 4000 Luxottica Place, Mason OH 45040 ® 6 Creamery Brook, East Granby, CT 06026 ® +1(513) 765-6000 ® +1(516) 393-2484 Stare 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for �o LLJ O '5o C O UQ x O C N G QJ O0_ 03 O Z o Us Qo Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: IXI Client Review ® DOB Permit ❑ DOB Permit - Re -Submit El LL Approval El Bid IBI Construction Title FINISH PLAN Date Sheet 6/2017 Dra04/ SEVwn By A103 Checked By DAF SH SCHED FINIULE ITEM ' VIARK DESCRIPTION MFG./PHONE # MODEL #/COLOR REMARKS ARCHITECTURAL D A L SPECIFIC ATIONS / FINISHES NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE I� 1�7 V RH SPECIFICATIONS GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS FINISHES WALLS PAINT P101 PAINT (EGGSHELL) (EXTRA WHITE) SHERWIN WILLIAMS (800) 474-3794 INTERIOR ACRYLIC LATEX EXTRA WHITE, SW7006 INTERIOR WALLS AND SOFFITS PAINT P104 PAINT (SEMI GLOSS) (EXTRA WHITE) SHERWIN WILLIAMS (800) 474-3794 INTERIOR ACRYLIC LATEX EXTRA WHITE, SW7006 DOOR FRAMES EVERYWHERE PAINT P114 PAINT (EGG SHELL) SHERWIN WILLIAMS (800) 474-3794 SW7066, GRAY MATTERS ACCENT WALL PAINT - OD AREA PAINT P117 PAINT (SATIN) SHERWIN WILLIAMS (800) 474-3794 SW7068 GRIZZLE GRAY MDF FILLERS AT EYE EXAM SIGN WALLCOVERING WC105 WALLCOVERING WOLF GORDON INC. HEIDI SCHWARZINGER REEF RFF 2557 VINYL WALLCOVERING WITH OSNABURG BACKING - COLOR: ANCHOR 800 347 0550 X864; MOBILE 330 6181296 HEIDI.SCHWARZINGER@WOLFGORDON.COM WALLCOVERING WC106 WALLCOVERING SOURCE ONE CONTRACT MIKE THOMPSON, 614-551-7928 TEXTURA STONE, COLOR: BLACK DIMENSIONS: 12"X24", 1.5 MM. THK. LOCATION: REFERENCE ARCHITECTURE DRAWINGS FOR LOCATIONS & SEAMING. NOTES: PRODUCT IS GLUED TO WALL WITH STANDARD POLYURETHANE ADHESIVE. INSTALL TILES HORIZONTALLY. BASE WB101 WOOD WALL BASE H /8" TOP CHCRWOOD BASE W/ 3/AMMPAINTED FER W FINISH - P104 BASE WB102 WOOD WALL BASE H 3/8" TOP CHCH4"TPAIAWOOD BASE W W/ AMMFFER FINISH - P104 BASE DWB101 MILLWORK WALL BASE JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 -1040 R S E A B O LT @ C DC DIST.CO M MODEL/COLOR: MANDALAY, MW -50-H6, 50 WHITE FOR USE ON ROUND COLUMNS ONLY CHAIR RAIL CR100 CHAIR RAIL JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 -1040 R S E A B O LT@ C DC DIST.CO M CHR -50-C OD WAITING, EXAM & PRETEST (PER ELEVATIONS) CORNER GUARD CG100 VINYL CORNER GUARD JOHNSONITE TANDUS 50 WHITE VBG -50-A-48 USE ON EXPOSED OUTSIDE CORNERS IN O.D. & B.O.H. PORCELAIN TILE PT105 PORCELAIN TILE (7 7/8" x 19 5/8" x 1/4" THK) DESIGNER TILE & STONE ARCTYC, WHITE GROUT: 1/16" THK., MAPEI #38 AVALANCHE 8 X 20 STOREFRONT PORTAL FRAME, INSIDE WD201. VERIFY W ELEVATION FLOORING PORCELAIN TILE PT108 LARGE FORMAT PORCELAIN TILE 24"x24"x10mm TRANSCERAMICA ITASCA W BRYN MAWR IL60143 NOREEN SCHERTLER (312) 342-4689SPECIFICATIONS. ROADS; ITEM #P66201 - SQUARE GREY CALM, (MATTE FINISH) GROUT: 1/16' THK., MAPEI #27 SILVER (NO SUBSTITUTIONS) MANDATORY INSTALLATION PER MANUFACTURER'S PORCELAIN TILE PT109 LARGE FORMAT PORCELAIN TILE A.) 24'x24'x10mm #PFP2960 B.) 24'x6'x10mm #PFP2965 ERAMICA 1159 W 1159 W BRYN MAWR ITASCA IL 60143 NOREEN SCHERTLER (312)342-4689 NEW GROUND; ANTHRACITE GROUND, (HONED FINISH) GROUT: 1/16' THK., MAPEI #47 CHARCOAL (NO SUBSTITUTIONS) MANDATORY INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. CARPET TILE C63 CARPET TILE 24"x24", ULTRA NYLON 6,6 J&J INVISION JEFF TAYLOR (P): (800) 241-4586 STACKED MODULAR, 1404 STIMULATE 24x24 TILE MONOLITHIC INSTALLATION, INSTALL MUST INCLUDE MFG. RECOMMENDED INSTALL METHOD, FLOOR PREP & ADHESIVE CEILING CEILINGS AC -4 2' x 2' LAY -IN; 15/16" GRID ARMSTRONG (800) 442-4212; OPTION #1 1774 DUNE TEGULAR, z'xz'xs/a ANGLED TEGULAR PRELUDE 15/16' EXPOSED TEE GRID SYSTEM CLASS "A", REFERENCE "LUXOTTICA" AS ACCOUNT NAME , MILLWORK ALUMINUM A-1 ALUMINUM TIGER (800) 898-4437 TIGER DRYLAC 49/80180 STOREFRONT GLAZING CHANNELS, 12' LENGTHS. STOREFRONT BASE, & 2" REVEAL PROFILE. PLASTIC LAMINATE PL100 PLASTIC LAMINATE WILSONART (800) 433-3222 FROSTY WHITE #1573-60 MATTE W/SOLID COLOR CORE @ EXPOSED EDGES MILLWORK PLASTIC LAMINATE PL102 PLASTIC LAMINATE FORMICA MICHAEL HERTENSTINER (440) 668-7030 DECOMETAL COLLECTION 2022 BRUSHED ALUMINUM MILLWORK PLASTIC LAMINATE PL103 PLASTIC LAMINATE FORMICA MICHAEL HERTENSTINER (440) 668-7030 COLORCORE2 COLLECTION 7223C-58 NEW WHITE (MATTE) MILLWORK PLASTIC LAMINATE PL105 PLASTIC LAMINATE WILSONART (800) 433-3222 7964K-12 SKYLINE WALNUT DOORS (ALL SIDES INCLUDING BOTH FACES, LATCH SIDE, HINGE SIDE, &TOP) MILLWORK FINISH PC100 MILLWORK POWDERCOAT MATTHEWS PAINT MP30136R11950 POWDERCOAT SOA V1.0 BRUSHED ALUMINUM MILLWORK ARCHITECTURAL METAL TRIM M102 METAL STYLMARK NADINE KING (763) 574-7474 RECTANGULAR TRIM #110672 W/ BASE #412007 FINISH 120 TRIM DETAIL FOR WALLCOVERING, 2 -PART ASSEMBLY MELAMINE MEL100 MELAMINE PANOLAM (800) 672-6652 S557 INTERNATIONAL WHITE / CRYSTAL TEXTURE MILLWORK TRANSITION STRIPS TRANSITION STRIP TS -1 TRANSITION STRIP (CARPET TO TILE) JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 -1040 RSEABOLT@CDCDRT.COM PART # CCA -XX / #32 PEBBLE FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE DEVELOP:NA, FUEL CONTRIBUTED: NA TRANSITION STRIP TS -2 TRANSITION STRIP (CARPET TO CONCRETE) JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 -1040 RSEABOLT@CDCDJT.COM PART # EG -XX -K / #32 PEBBLE FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B. SMOKE DEVELOP:NA, FUEL CONTRIBUTED: NA TRANSITION STRIP TS 4 TRANSITION STRIP (CARPET TO VINYL AND CARPET TO PORCELAIN) SCHLUTER WWW.SCHLUTER.COM 1-800-472-4588 SCHIENE, MINIMAL HEIGHT AS APPROPRIATE FOR FLOORING TRANSIITON ALUMINUM (-A);1/4' THICK EDGE. ZINC STRIP AT OD AREA. TRANSITION STRIP TS -9 TRANSITION STRIP (PORCELAIN TO VINYL) JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513) 560 -1040 RSEABOLT@CDCDIST.COM PART # CTA -XX -K / #32 PEBBLE BETWEEN PORCELAIN TILE & VINYL TRANSITION STRIP TS 10 TRANSITION STRIP (PORCELAIN TO MALL TILE FLOORING) SCHLUTER WWW.SCHLUTER.COM 1-800-472-4588 SCHLUTER - DECO, ALUMINUM (-A) HEIGHT AS APPROPRIATE FOR FLOORING TRANSITION, 1/4' THICK ALUMINUM EDGE BETWEEN RETAIL TILE AND EXISTING AISLE TRANSITION STRIP TS -12 TRANSITION STRIP (VINYL TO CONCRETE) JOHNSONITE ROD SEABOLT CDC DISTRIBUTORS (513)560- 1040 RSEABOLT@CDCDIST.COM PART # RRS-XXC #32 I(:., I �VVED FOR ' ODF POMP) l A NC ME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE D VELOP:NA, FUEL CONTRIBUTED: NA E ', APPROVED • ,.f r 'JUN 2 9 2017 RECEIVED SEALER PRIMER/SEALER LATEX PRIMER / SEALER FOR DRYWALL ICI DULUX PAINTS (502) 969-0181 # 1020-1200PVA '' 'S CITY OF TUKWILA E (1) COAT REQUIRED PRIMER/SEALER LATEX PRIMER / SEALER FOR METAL ICI DULUX PAINTS (502) 969-0181 DEVGUARD #41city Of Tu H 0 E (1) COAT REQUIRED MAY 18 2017 PRIMER/SEALER LATEX PRIMER / SEALER FOR WOOD ICI DULUX PAINTS (502) 969-0181 WOOD UNDERC WILDING D1V S1O E (1) COAT REQUIRED PERMIT CEi�ITEI� TRIM CASING T101 HARDWOOD CASING - PAINTED 3/4" x 3/4" HARDWOOD SQUARE FINISH - P104 (TYP. WHERE PT105 MEETS MILLWORK) CASING T102 HARDWOOD CASING - PAINTED 6 3/8" W x 3/ PAINTED HARDWOOD CASING FINISH- P104 (TYP. AT S., I. ENTRY) 4��� �fb�• 6Y 7II ,. ,• l� , °,-A103-REV00 1 1 UI' DESIGN & CONSTRUCTION MANAGEMENT: RE ® 4000 Luxottica Place, Mason OH 45040 ® 6 Creamery Brook, East Granby, CT 06026 ® +1(513) 765-6000 ® +1(516) 393-2484 Stare 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for �o LLJ O '5o C O UQ x O C N G QJ O0_ 03 O Z o Us Qo Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: IXI Client Review ® DOB Permit ❑ DOB Permit - Re -Submit El LL Approval El Bid IBI Construction Title FINISH PLAN Date Sheet 6/2017 Dra04/ SEVwn By A103 Checked By DAF DESIGN & CONSTRUCTION MANAGEMENT: RE o 4000 Luxottica Place, Masco, OH 45040 o 6 Creamery Brook, East Granby, CT 06026 0 +1 (513) 765-6000 ® +1(516) 393-2484 Store 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for tign CD O LLJ O dam' Fl= 0 V0 o O a) UO E- 35)7) O Q Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AlA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: NI Client Review ®DOB Permit ❑ DOB Permit - Re -Submit ® LL Approval ® Bid ® Construction Title INTERIOR ELEVATIONS Date Sheet 04/06/2017 Drawn By SEV A200 Checked By DAF GC TO PROVIDE AND INSTALL MDF FILLERS CW WC105> G.C. TO PROVIDE AND INSTALL 1X6 FIRE -RATED WOOD BLOCKING IN WALL BEHIND GYP. BD. BETWEEN EACH STUD FOR �. SOFFIT @ 10'-6 3/4" WALL FIXTURE MOUNTING. (TYPICAL WHERE WALL FIXTURES �` FOLLOWING INSTALLATION OF ,GN. SEE w P101 > 1 X CAT 6 HUBBELL HXJ6BK 1 X DUPLEX (BLACK) 1 X DATA (ETHERNET; FOR SPEC OF CABLING TYPE. SEE 8'-2" DETAIL 6 / A400. ' PAINT MACY'S WHITE ARE SHOWN) A500 ; ` MATCH EXISTING MACY'S FINISHES IIIIIIIHIIIIIMIIIIIIIIIM -_ -_ ELEC DRAWINGS) 4' 1" LENSCRAFTERS4'-1" -, BIR PROVIDE IN WALL (2) q' CONDUIT FROM IN -WALL BOX TO 6" ABOVE CEILING - ilii i�. - EXAMS \IIIN-WALL: o .-t o N / \ C u 4___\_. ni �J Oil r 17-7-1 1 11 - SW ARLTVBU505BL ARLINGTONTM' TVBU505BL TWO -GANG RECESSED �ie�iw��� \ / viiiiiivvii(►iwivO •, iiiiiiiiii •iiiiiiiii •iii r�wwv���»vwwvv�� •iii�vi vvwvii \ \ U,' �Id i ELECTRICAL BOX (BLACK), OR EQUAL co 2 (�I - 1 \ , =1oo Ol ` -i \ �-^ iI LL - f -O '''''-9- * -" BLACK IN COLOR) 2 X DUPLEX (BLACK) s -i — fl r1 9 — \ / tnia0 OPEN — I _ a, 0 OPEN o EXTENDED FROM TOP BOX - 1`os20 uU 1 _ CORRIDOR XB-DFQS5 n t\ 9 / \ - u " -) i ) I 1 ) MATCH EXISTING MACY'S WALL BASE. v,l� 8" 20" I I 1 I — sr- Fr, x OPENING IN BACK OF MILLWORK FOR POWER ACCESS, BY 0420-00 - 0 0420-00 WRAP u o u u MILLWORKER WALLCOVERING \ TO CORNER �_ / • \ \ \ 1 n 0440-00 0400-00 0430-00 0' • e £ 00 0821-00 0440-00 043(P 1430 00 0400-00 0430-00 0400-00 0431P661 430-00 0400-00 0410-00 CM -EE -CS 4'-12" 1„ 8 x 20" OPENING IN BACK OF MILLWORK FOR POWER ACCESS, BY MILLWORKER 1A RETAIL SALES AREA 100 Kg WB101 T T102 // (B WB101 '-48" 34'-88" 1' 48" R.O. HOLD 3 62 < B \ W8101) \\ �., (.2) CONTACT LENS ROOM: 104 A200 RETAIL SALES AREA 100 01 SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" — GC TO PROVIDE AND INSTALL CABINET HANDLE BUMPERS AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN OPEN POSITION. SEE DETAIL 4 ON . GC TO PROVIDE AND INSTALL CABINET ©I P101 HANDLE BUMPERS AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN ©M w P101 > SHEET A500. © P1o1 OPEN POSITION. SEE DETAIL SHEET 4 ON A500. ' \ ♦ 2'-7" \ GC TO PROVIDE AND INSTALL CABINET HANDLE BUMPERS AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN SEE DETAIL 4 ON 1.• '� / o \ 7:1) \ � V. ♦ —\- op o OPEN POSITION. SHEET A500. Ei) \ ( o \ o � b. 1 j� a0 \ \ O 1840-00 1840-00 pp O N / \ 1840-00 1840-00 1840-00 71 I I I r` LCI-GH30 '--1 I o• En N miN / \______ �� F., 4 l u 0 ' (�fN O� r " Ln m F.1 \ i r- , \ I I \ \ 1861-00 / (B \ WB102 \ 1864-00 SINK 'SK -3' j / RE: PLUMBING \ \ \ \ 861 00 \ / \ 1843 00 1863-00 T \ \ 1843 00 // (B \\ WB102 // (B \ \\ W6102) // ( B \ (---6 OPTICAL STATION: WB102/ 103 C B WB102 CONTACT LENS ROOM: 104 DRAWINGS CONTACT LENS ROOM: 104 CONTACT LENS ROOM: 104 OPTICAL STATION: 103 4 SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" Ej)SCALE: 1/4"=1'-0" SCALE:1/4"=1'-0" an © P101 © P101 © P101 © P101 EQ. / EQ• EQ- \ io o \EQ o ryT : ) / �8°� / / RECESSED / =O , ~mi. 0 , LC M -G -G' 2 ELECTRICAL PANEL PAINT P101 > a O N o o p , WV s°.ww. o ,-+ LC -GH16 — \ O ,� O - 1846-00 ii- Zzt r-4 \ O En LCI-GH30 LCI-GH30 ro (DOO •. PL105) (FRAME " 04) 1'-0" r+) O /\. c-�1 rf N \ \ J I/ 11 WB102 B WB102 B WB102 r OPTICAL ♦ STATION: \ 1843-00 103 B WB102 PRETEST ROOM: 102 PRETEST ROOM: 102 PRETEST ROOM: 102 PRETEST ROOM: 102 10 SCALE: 1/4"=1' 0' SCALE: 1/4"=1'-0' 11 SCALE: 1/4"=1' 0" SCALE: 1/4"=1'-0" 8 SCALE:1/4"=1' 0" GC TO PROVIDE AND INSTALL CABINET 24524"x1/4" PLEXI SHIELD. COORDINATE DIMENSION FROM BACK WALL INFIELD. PLEXI TO PROTECT WALL FROM SWING OF EQUIPMENT ARM. FASTEN TO STUDS OR TOGGLE BOLT (8) SCREWS. ADDITIONAL PLEXI PIECE MAY BE REQUIRED DUE TO SITE CONDITIONS. GG TO VERIFY WITH DR. HANDLE BUMPERS AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN CW P114 > // ' (W \\ P101 > / (w P101 ) © P101 OPEN POSITION. SEE DETAIL 4 ON SHEET A500. 2'-6" C.L. A.F.F. IN WALL 6" FIRE -RATED WOOD BLOCKING / \ / 4'-9". EQUIPMENT / SCREWS FOR PLEXI SHIELD / REVIEWED FOR CODE COMPLIANCE r APPROVED {' � JUN 2 0 2017 (� '� CES 4�i Tukwila BUILDING- - . r,r RECEIVED CITY OF TUKWILA MAY 18 2017 RMIT CENTER \ ELEC. OUTLET OUTLINE OF RECESSED PROVIDED AND INSTALLED BY G.C.4'-21 GRAINGER WASHER, #8 ITEM # 2DE99 MFR. MODEL # 908018 -PG COUNTERSUNK WASHER, NICKEL OUTLET BOX. RE: ELEC DRAWINGS t 0 ^ o o 4 co 0 in - FWISH, FITS BOLT SIZE #8, INSIDE DIA 0.210 IN, OUTSIDE DIA 17/32 IN, 0 V I.F. � 0 o Ct � I \ o o in ° °O -0" AL OUTLET 5'-6" IPMENT FOR FINISHED APPEARANCE. o FOR USE WITH 82 DEGREE FLAT r ° " " i� 1856 00 • 1856 00 1856 00 \ T �— io �� \ AND OVAL HEAD COUNTERSUNK SCREWS. " " " " (DOOR-PL10 0FRAME P104> / O O 2 \ SE TOWEL io ;:-i � �c - O i N 1853.00, io 0 . 62 w t j W w/ r 41.. 6 855-00 O ,� lV <y N • -J y-0" COAT , . • . • �7 lV � M•Ni 4 � O i 185'-00 ^� \ \ \ (B \ WB102) _ 1853-00 / CB \ - WB102 ) / (WB102 B) T SINK 'SK -7' 15" (wBlo2 B) RE: PLUMBING DRAWINGS EXAM ROOM EXAM ROOM EXAM ROOM EXAM ROOM 15 SCALE: 1/4"=1'-0" 16 SCALE: 1/4"=1'-0" 14 i SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" DESIGN & CONSTRUCTION MANAGEMENT: RE o 4000 Luxottica Place, Masco, OH 45040 o 6 Creamery Brook, East Granby, CT 06026 0 +1 (513) 765-6000 ® +1(516) 393-2484 Store 08932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for tign CD O LLJ O dam' Fl= 0 V0 o O a) UO E- 35)7) O Q Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AlA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: NI Client Review ®DOB Permit ❑ DOB Permit - Re -Submit ® LL Approval ® Bid ® Construction Title INTERIOR ELEVATIONS Date Sheet 04/06/2017 Drawn By SEV A200 Checked By DAF OA MAIN SUPPORTS: EXISTING 2ND FLOOR 3 $" x 20GA METAL STUD DIAGONAL BRACING TO STRUCTURE ABOVE CONCRETE AND METAL DECK OVER STRUCTURAL STEEL 12 GAGE HANGER WIRES AT 4'-0" O.C. EACH WAY OPERIMETER WIRES: 1 v r1 n n n n n n n /1 B.O. DECK 12 GAGE PERIMETER WIRES INSTALLED WITHIN 8" OF WALL AT EACH MAIN AND CROSS TEE TO WALL JUNCTURE ' O LIGHT FIXTURE SUPPORT: 3 5/8" X 20 GA DIAGONAL > 3"X3"X3"X18 GA CUP ANGLES TO BRACING @ 48" O.C. • •l1 15'-7 3/4" A.F.F. A ALTERNATING TO THE STRUCTURE O 0 TOP TRACK AND DIAGONAL BRACING W/(2) #10 SCREW CONNECTIONS, EA. LEG. CUP ANGLES AT 48" O.C. MAX. 12 GAGE WIRES ATTACHED • OF FIXTURE AT EACH CORNER. TO FIXTURE (OPPOSITE CORNERS), INSTALL ONE SCREW AT OR CROSS TEES. TO MAIN OR CROSS TEES WITHIN 3" AND 12 GAGE SAFETY WIRES ATTACHED EXTENDING TO STRUCTURE ABOVE. OPPOSITE CORNERS OF FIXTURE TO MAIN _ _ # – ° O _ FIRE PROOFED STRUCTURE G.C. TO REPLACE ANY FIRE PROOFING DAMAGED BY NEW WORK. 3 5/8" X 20 GA TRACK 3 $" 20GA METAL STUD B I 1 AIAGONAL ALTERNATINGGTO ABOVE, x BRACING STRUCTURE 48" O.C. (TYPICAL) f n ACOUSTCAL CEILING ' ACOUSTCAL CEILING A300 L TRACK TO BRACE < DETAIL METAL STUDS SECTION DETAIL 3 5/8° X 20GA RUNNER TRACK _„� , SECURED TO WALL STUDS W/ #10 SCREWS SUSPENDED ACOUSTICAL +_\ SAFETY WIRES T O 4 SCREW %441111WI 1.41* •Nli CEILING REFER REFLECTED SCALE: 3"=r-0” CEILING PLAN FOR CEILING HEIGHTS 3 5/8" METAL STUDS @ 16" NOTES: A.) WALLS SHALL BE PLUMB TO WITHIN O.C. WITH 5/8° TYPE °x° GYP. BD. 1/8" TOP & BOTTOM AT MILLWORK NS B-) SEE ELEVATIONS FOR WALL FINISHES ,,•44iRkiw..mui4itli' \— O'' ` OD RETAIL AREA \� SCREW 3 5/8° X 20GA TRACK % LIGHT FIXTURE (ThSUSPENDEDCEILING / /TO `�4V44111111. CEILING TILE YP) �� DETAIL METAL "T" BAR CONTINUOUS (2) #10 SCREWS EA. METAL STUD SECURED TO SLAB.,4 < METAL STUDS SECTION DETAIL . METAL TRACK PER SECTION DETAIL HILTI X-ZF # 32 P8/36M (0.145" SHANK DIA) r C I _ r BASE PER FINISH PLAN /SCHEDULE. REFER TO SHEET A103 FASTENERS @ 16" O.C. (OR EQUAL) CONCRETE SLAB A300 I I I WALL SECTION TRACK TO SLAB DETAIL CC SCALE: 3"=1'-0" SCALE: 1/2"=1-0 _..) SCALE: 3/4"=1'-0" TYPICAL INTERIOR PARTITION 03 EXISTING 2ND FLOOR EXISTING 2ND FLOOR EXISTING 2ND FLOOR 3 � „ x 20GA METAL STUD 3 �„ x 20GA METAL STUD 3 s" x 20GA METAL DIAGONAL BRACING STRUCTURE ABOVE STUD TO CONCRETE AND METAL DECK OVER STRUCTURAL STEEL $ DIAGONAL BRACING TO STRUCTURE ABOVE CONCRETE AND METAL DECK OVER BAR JOISTS $ DIAGONAL BRACING TO STRUCTURE ABOVE CONCRETE AND METAL DECK OVER BAR JOISTS v n n n n n n n n B.O. DECK 1 Y n n n n n n n /1 B.O. DECK -1 n ,, n n n n n n r\ n n B.O. DECK • • 15'-7 3/4" A.F.F. • • 15'-7 3/4" A.F.F. A 0 15'-7 3/4" A.F.F. FIRE PROOFED STRUCTURE G.C. TO REPLACE ANY FIRE PROOFING DAMAGED BY NEW WORK. FIRE PROOFED STRUCTURE G.C. TO REPLACE ANY FIRE PROOFING DAMAGED BY NEW WORK. 3 $" x 20GA METAL STUD 3 $" 20GA METAL STUD B I _ I DIAGONAL BRACING ALTERNATING TO STRUCTURE ABOVE, 48" O.C. (TYPICAL) B _ x DIAGONAL BRACING ALTERNATING TO STRUCTURE ABOVE, 48" O.C. (TYPICAL) A300 - r - I co b..,I A300 L - - I �,,.,.�....... `� 3 5/8" X 20GA TRACK ,...... ..1,,. 3 5/8" X 20GA TRACK / ^ #10 SCREWS TO EA. METAL (2) #10 SCREWS TO EA. METAL O (2) STUD 0SUSPENDED ACOUSTICAL CEILING REFER REFLECTED CEILING PLAN FOR CEILING HEIGHTS STUD ...� SUSPENDED ACOUSTICAL CEILING REFER REFLECTED CEILING PLAN FOR CEILING HEIGHTS ' REVIEWED FOR CODE COMPLIANCE APPROVED I 202017 3 5/8° METAL STUDS @ 16° NOTES: A.) WALLS SHALL BE PLUMB TO WITHIN 3 5/8° METAL STUDS @ 16° NOTES: A.) WALLS SHALL BE PLUMB TO WITHIN 6° METAL STUDS @ 16" O.C. ' i' UH • O.C. WITH 5/8" TYPE °x" GYP. BD. _ 0 1/8" TOP & BOTTOM AT MILLWORK LOCATIONS B.) SEE ELEVATIONS FOR WALL FINISHES O.C. WITH 5/8° TYPE "x" GYP. BD. 0 1/8" TOP & BOTTOM AT MILLWORK LOCATIONS B.) SEE ELEVATIONS FOR WALL FINISHES WITH 5/8' TYPE "x° GYP. BD. > 0 City of Tukwila BUILDING DIVISION 5/8° TYPE °x° GYP. BD. OD AREA OD AREA VOID SPACE OD AREA (ONE SIDE ONLY) VOID SPACE • 3 5/8" X 20GA TRACK 3 5/8° X 20GA TRACK COMBUSTIBLE NOLS 3 5/8" X 20GA TRACK (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB O (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB 0 CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB 0 SHALL WITHIN DBE PERMITTED WITHIN THE VOID SPACE. CITY OF TUKWILA r C I BASE PER FNISH PLBASE 1 /SCH DULEI REFER ON SHEET A103 r c IA103 l /SCH DULEI REFER OBASE PER FNISHN SHEET PER FNISH PLAN /SCH DULEI REFER TO SHEET r A103 c 1 JUN 28 2017 I A300 I( I A300 I i I A300 I^ I PERMIT CENTER 1--- ALL SECTIO L _ _ _ J L___J ALL SECTIO r WALL SEC L_J � � t G.C. TO PROVIDE HORIZONTAL AND VERTICAL FIRE B ACKING @ 10 O.C.MAX ASRE�+a'EDBYTHE a :.DIN 718 45)SCALE: 3/4"=1'-0" FURRED CMU WALL SCALE: 3/4"=1'-0" FURRED CMU WALL SCALE: 3/46"=1'-0" DESIGN & CONSTRUCTION MANAGEMENT: RE O 4000 Luxottica Place, Mason, OH 45040 ® 6 Creamery Brook, East Granby, CT 06026 o +1 (513) 765-6000 o +1 (516) 393-2404 Store #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: Cign LIU QO O `41 - Ems, O LE V O C NO N � V O c (13 O _I � O Q d00' Macy's Store Number: Revisions: Mark Date By A4/10/17 ST CLIENT COMMENTS A6/02/2017 SNT CLIENT COMMENTS A6/15/2017 SEV CITY COMMENTS A A Architect of Record MATTHEW D. WITTIER AIA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review ❑DOB Permit ❑DOB Permit - Re -Submit ❑ LL Approval ❑ Bid ® Construction Title SECTIONS DateDrawn By Sheet 04/06/2017 A300 Checked By DAF \ / .:-•`° CABINET HANDLE WALL MICO\-- 6" WALL BASE mm c3 `O FINISH: P104 PROVIDED AND INSTALLED BY G.C. FINISH FLOOR, SEE SHEET A103 ° o s' • ' • BUMPER PROVIDED AND INSTALLED BY GC SEE SHEET A100 ARCH. FINISH SCHEDULE FOR MODEL INFORMATION. PROVIDE WHERE ANY CABINET DOOR HANDLE CAN MEET WALL SURFACE IN OPEN POSITION. PARTITION PER CONSTRUCTION PLAN J ABOVE CEILING @ 10'-6" A.F.F. > •- '.' 1• :. . -BOX .- BY ELECTRICAL CONTRACTOR WITH FLEX CONDUIT WHIP ROUTED IN WALL THRU CASING . SEE ELECTRICAL DRAWINGS c� 1111111111111111111)1111 4 CABINET DOOR HANDLE - WALL BUMPER WALL BASE DETAIL B.O.O.D.CEILING 1/111111 11111III� 10'-0" I) 10'-0" \--- A N ACT CLG > SCALE: 6"=1'-0" 3-LCM17-A500-REV00 OD SCALE: 6" =1'-0" 4-LCM17-A500-REV00 m�7r ACT CLG ; T.O. TRIM = 9'-3 5/8" A.F.F. • �B wBiai) CORNERBEAD rv`, LEI T T102 ILLUMINATED "EYE EXAM" SIGN CASED OPENING TRIM --1 CABINET BY SIGN CONTRACTOR, PAINTED "P104" to V \ T (BACKSIDE) 4%,I' - / < (T T102 .t; SIDE MDF FILLERS BY GC BACKSIDE OF SIGN sq. < 6 3/8"W x3/4"T TRIM -PAINTED P104 - GLUED & SCREWED. COUNTER SINK SCREWS, FILL AND PREPARE FOR PAINT. PROVIDED AND INSTALLED BY G.C. SEE ELEVATION SHEETS A200 & A201 ALIGN TO CABINET: B.O. SIGN CABINET v 1/2"THK X 1'-5 1/2"H x 21/2"W PAINTED MDF 1 1, 22 8'-0" (EQ. THK. FILLER @ EA. SIDE BY GC) FINISH P117 FINISHED OPENING BETWEEN vow -ei NON-COMBUSTABLE BLOCKING FILLERS SHALL BE 3'-11" HOLD. SECTION THRU - EYE EXAM i -11 3" SIGN SIGN CAB. THK. • > LINE OF SIGN " Cw T102 ABOVE ti (B CASED OPENING WB101) - DETAIL SCALE: 6" =1'-0" 5-LCM17-A500-REV00 SCALE: 1 1/2" =1'-0" 1-LCM17-A500-REV00 TRANSITION STRIP (TS -4) PER PLANS AND SCHEDULES INSTALL CARPET ON SUBFLOOR TO TS -10 TRANSITION STRIP PER PLANS AND SCHEDULES ALIGN ALIGN CARPET PILE HEIGHT WITH ADJACENT FINISHED TILE FLOORING PORC. TILE ON THIN SET MORTAR BED _ -• ° 4• ' MORTAR Y alffiOOOOoOOOga �11�� .�.�111 ,d 4 • A (THIN SO- BED - - .a .'•• a LME OF EXISTING CONCRETE : • -" • • ° • • GLUE DOWN CARPET PER PLANS AND SCHEDULES 1/2" F.R. PLYWOOD SUBFLOOR-VERIFY 10 FLOOR TRANSITION DETAIL I SLAB NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION. HEIGHT REQ'D IN FIELD 9 LINE OF EXTG. CONCRETE SLAB FLOOR TRANSITION DETAIL SCALE: 6" =1'-0" TS -4 CARPET TO PORCELAIN 9-LCM17-A500-REV00 SCALE: 6" =1'-0" 10-LCM17-A500-REV00 ' REVIEWEDPROVEFOR CODE COMPLIANCE { APD -. 'JUN 29 2011 City of Tukwila BUILDING DIVISION ......,.....mss RECEIVED CITY OF TUKWILA MAY 18 2017 D1 ,,,E IT e n;; TER I DESIGN & CONSTRUCTION MANAGEMENT: RE ® 4000 Luxottica Place, Mason, OH 45040 O 6 Creamery Brook, East Granby, CT 06026 0 +1(513) 765-6000 0 +1(516) 393-2484 Store *8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: CZo L4 ra 0 Oc < 3 co X O a N V UC) E- 3to X -93 l/7 C) Q c: 0.1 -4( Macy's Store Number: Revisions: Mark Date By A A A A A Architect of Record MATTHEW D. WITTMER AlA, LEED-AP 12 CANAAN WAY SIMSBURY,CT 06070 PHONE: (860)246-1624 mwittmer@phasezerodesign.com Seal 4/7/2017 Architect / Engineer Job No.: A/E JOB NUMBER Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: BRAND/TYPE ISSUED FOR: ®Client Review ®DOB Permit ❑DOB Permit - Re -Submit i LL Approval ® Bid ® Construction Title DETAILS Date 04/06/2017 Drawn By XXX Checked By DAF Sheet A500 DIVISION 150006 - MECHANICAL I. GENERAL PROVISIONS A. GENERAL CONDITIONS, CODES & STANDARDS 1.ALL WORK SHOWN ON THE MECHANICAL DOCUMENTS IS TO BE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR, UNLESS NOTED OTHERWISE. 2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO INSTALLATION. 3. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. B. SCOPE OF WORK 1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE MECHANICAL CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN THE MECHANICAL CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. DURING BIDDING: 2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. C. DOCUMENTS 1.SUBSTITUTIONS 1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE INDICATED. 2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. D. CONSTRUCTION COORDINATION 1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. 2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. II. INSULATION DIVISION 15000A - PLUMBING PART 1 - GENERAL A. GENERAL CONDITIONS, CODES & STANDARDS 1. ALL WORK SHOWN ON THE PLUMBING DOCUMENTS IS TO BE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR, UNLESS NOTED OTHERWISE. 2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO INSTALLATION. 3. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. B. SCOPE OF WORK 1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE PLUMBING CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN THE PLUMBING CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. DURING BIDDING: 2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.3. WHERE THERE ISA CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. C. DOCUMENTS 1.SUBSTITUTIONS 1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE INDICATED. 2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. D. CONSTRUCTION COORDINATION 1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. 2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. PART 2 - MATERIALS A. GENERAL 1.PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE EXPOSED, CHROME PLATED PIPE IS TO BE USED. 2. ALL ABOVE GROUND PIPING SHALL BE INSULATED WITH FIBERGLASS PIPING INSULATION WITH AN ALL SERVICE JACKET AND SELF SEALING LAP (ASJ/SSL). 2.1 DOMESTIC HOT AND COLD WATER PPING UP TO 3/4 INCH DIAMETER -1/2 INCH THICK. 2.2 FITTINGS AND VALVES SHALL BE INSULATED WITH PRE -MOLDED FIBERGLASS FITTINGS AND COVERED WITH A PRE -FORMED PVC FITTING COVER. PART 3 - EXECUTION A. GENERAL 1.THE ENTIRE PLUMBING INSTALLATION, MATERIALS, EQUIPMENT, ETC. SHALL CONFORM TO THE REQUIREMENTS OF THE LOCALLY ENFORCED CODES AND STANDARDS. 1.1. VERIFY FINAL ROUGH IN WITH ARCHITECT PRIOR TO WALL INSTALLATION. 2. PIPING IS TO BE INSTALLED CONCEALED - SURFACE MOUNTED PIPING IN FINISHED AREAS IS NOT ACCEPTABLE. 3. ALL EXPOSED OR ACCESSIBLE P -TRAPS MUST BE PROVIDED WITH BOTTOM CLEANOUT PLUGS. 4. INSULATE EXPOSED P -TRAPS, HOT AND COLD VALVES AND PIPING SERVING HANDICAPPED LAVATORIES. 5. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70.FLUSH 6. ALL CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR OR WALL. B. INSULATION 1.EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR PENETRATIONS. 2. MAINTAIN ACCESS TO VALVES DIVISION 16000 - ELECTRICAL PART I GENERAL A. GENERAL CONDITIONS, CODES & STANDARDS 1.ALL WORK SHOWN ON THE ELECTRICAL DOCUMENTS IS TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK.FOR THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED4. FEES OR COSTS. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. 5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. B. SCOPE OF WORK 1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE HS WORK IS IN THE ELECTRICAL CONTRACTOR'S SCOPE - A ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. DURING BIDDING: 2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.3. WHERE THERE ISA CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. C. DOCUMENTS 1.SUBSTITUTIONS 1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE INDICATED. ITEMS NECESSARY TO COMPLETE 2. MISCELLANEOUSMSANBE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. D. CONSTRUCTION COORDINATION 1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. 2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. PART 2 - PRODUCTS A. WIRING DEVICES 1.DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 1.1. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES OR APPROVED EQUAL, HEAVY DUTY, WHITE. 1.3. GROUND FAULT CIRCUIT INTERRUPTER (GPI) DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE INDICATED. D. FIRE ALARM SYSTEM 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, 1.PROVIDED BY MACY'S. RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. PART 3 - EXECUTION 2.1. SINGLE POLE SWITCHES SHALL BE LEVITON #1221 A. GENERAL MISCELLANEOUS SERIES OR APPROVED EQUAL, SILENT ACTUATING, 1.ALL CONDUIT RUN IN FINISHED AREAS SHALL BE 20 -AMP, 120/277V, WHITE. CONCEALED. 2. 2.2. THREE POLE SWITCHES SHALL BE LEVITON #1223 2. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH SERIES OR APPROVED EQUAL, SILENT ACTUATING, BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT 20 -AMP, 120/277V, WHITE. PANELBOARDS. PANELBOARDS, FEEDER DEVICES, 3. DIMMERS SHALL BE LEVITON SLIDING DIMMER DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD SWITCH, OF A RATING, VOLTAGE AND WATTAGE SUITABLE MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL LOAD SERVED. COLORS OF DEVICES AND ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH COVERPLATES SHALL WHITE. NEC 110.16. COMBINATION WALL DIMMER/OCCUPANT SENSOR 3. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR SHALL BE LUTRON MAESTRO 0-10V DIMMER WITH NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. INTEGRAL PASSIVE INFRARED OCCUPANT SENSING, 4. ALL FLUSH MOUNTED ;LOADCENTERS SHALL HAVE (3) AVAILABLE IN 1 -WAY OR 3 -WAY CONFIGURATIONS. 3/4` EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE COLOR TO BE WHITE. VERIFY LOAD SERVED IS CEILING FOR FUTURE USE. COMPATIBLE PRIOR TO ORDERING. 5. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, 5. WIRING DEVICES SHALL BE SPECIFICATION GRADE. ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN 6. COVERPLATES FOR POWER, DATA & TELEPHONE LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO SHALL BE LEVITON OR APPROVED EQUAL, WHITE, PLASTIC. ADDITIONAL COST TO THE TENANT. 7. LIGHTING CONTRACTORS SHALL BE IN NEMA 1 B. GROUNDING ENCLOSURE, NORMALLY OPEN ELECTRICALLY HELD,120V, OF THE ELECTRICAL SYSTEM SHALL BE BY COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES. MEANS INSULATED GROUNDING CONDUCTOR B. LIGHTING AND RECEPTACLE LOAD CENTERS(PANELS)INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS AND SUPPLEMENTAL AS 1.BRANCH CIRCUIT LOAD CENTERS SHALL BE DEAD FRONT REQUIRED TO MEET CODE (SUCH AS ARTICLE 517). TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS C TESTS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A 1.TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER MOUNTED SHEET STEEL ENCLOSURE. MINIMUM FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE SYMMETRICAL FOR 120/208V, AND 14,000 AMPS CORRECTED AT NO COST TO THE TENANT. SYMMETRICAL FOR 277/480V APPLICATION UNLESS D. DEMOLITION NOTED OTHERWISE. LOAD CENTERS MUST BE SELECTED TO FIT IN A STANDARD STUD WALL. 1.DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, IF 2. LOAD CENTERS SHALL BE AS MANUFACTURED BY APPLICABLE, SHALL BE PART OF THE ELECTRICAL WORK AS INDICATED ON THE DRAWINGS. SQUARE D, GENERAL ELECTRIC, ITE/SIEMENS AND WESTINGHOUSE/CUTLER HAMMER. C. FIXTURES AND LAMPS 1.ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT, INSTALLED BY ELECTRICAL CONTRACTOR.. A. GENERAL 1.EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, HANGERS AND SIMILAR PENETRATIONS. 2. MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES. 3. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE. 4. ALL DUCTWORK AND PIPING SHALL BE INSULATED VI. AIR DISTRIBUTION A. AIR DISTRIBUTION 1.DUCTWORK (ROUND OR RECTANGULAR OR SPIRAL) SHALL BE OF GALVANIZED STEEL CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA MANUAL AND1.GROUNDINGMEANSOFAN SEALED. 2. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15DEGREES. 3. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE DUCTWORKBUT IT'S USE IS LIMITED TO STRAIGHT HORIZONTAL OR VERTICAL RUNS. ALL CHANGES OF DIRECTION IN A DUCT SYSTEM (GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE GALVANIZED ELBOW. MAXIMUM LENGTH OF ANY FLEXIBLE DUCT IS 5'-0". 4. FLEXIBLE DUCTS TO DIFFUSERS: MAXIMUM LENGTH OF FLEXIBLE DUCT TO DIFFUSER TO BE 5'-0". VIII. TESTING AND BALANCING A. SYSTEM TO BE TESTED AND BALANCED WITH A REPORT SHOWING ACTUAL AIR FLOWS AT NEWLY INSTALLED DIFFUSERS. AIR FLOW TO BE WITHIN 15% OF THE DESIGN VALUE SHOWN ON THE DRAWINGS. WHERE THIS AIR QUANTITY CANNOT BE MET, ADJUST UPSTREAM DAMPERS UNTIL IT IS MET. COORDINATE THIS WORK WITH MACY'S OPERATIONS. 1. APPROXIMATE LOCATION OF 6" SANITARY LINE BELOW SLAB. FIELD VERIFY LOCATION OF PIPING AND CONNECT TO NEW LC MACY'S. CONTRACTOR IS TO SUGGEST ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING BIDDING/CONSTRUCTION. 2. UTILIZE PANEL "ELI" FOR THE 60A FEED TO NEW LOAD CENTER "A" IN THE LENSCRAFTER'S SPACE. VERIFY CURRENT LOAD ON PANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. SEE RISER DIAGRAM FOR PANEL IDENTIFICATION. 3. LOCATION OF EXISTING P.O.S. ROOM. 4. EXISTING WATER SUPPLY LOCATION. VERIFY IN FIELD PRIOR TO START OF WORK. 5. LOCATION OF VENT. FIELD VERIFY LOCATION AND CONNECT TO NEW LC MACY'S. CONTRACTOR IS TO SUGGEST ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING BIDDING/CONSTRUCTION 1-LCM-MPE100-REV 0.0 BLDG. REQ EXTERIOR WALL 1241.7 SALES SUPT. GENERAL STORA/5 87.8 °SALES SUPT- ❑ LOADING DOCK 1161.0 SALES SUPT. EMPLOYEE LOCKERS 100.7 EMPLOYEE ENTRANCE CUSTOMER PICKUP BLDG. REQ. SPRINKLER ROOM 112.7 LOCATION {1F BI C 1 Rl+ W ,VICEcT( TON OF ROPOSEI DTERS;P1 LOCATION OF'1 SANITARY' BEL SALES SJPT. 'IDES CONTROL ROOM 64.7 18.00. REQ. STAIRS 2216 11 13E SALES SUPT. AISLE CIRCULATION 80.1 ENTRANCE 93 BLDG. REO. ENTRANCE / VESTIBULE 238.0 BLDG REQ. MECHANICAL EQAIPUENT ROW 99.2 BLOC. REQ. TARS 201.2 SALES SUPT. STAGING 925.4 • SALES SUPT. RECEI'ONG / MARKING 2437.4 BLDG REQ. PASSENGER ELEVAT 91.1 ARIFS .UP SECURI 4760 FS USTYLE 763.2 FS OILER RETAIL 74.1 ESPOT FS L1 MSTYLE • 3019.5 0 SALES SUPT. UNUSED / 'ACE 102.3 INTIMATE APPAREL 9781 SALES SUPT. ELEVATOR LOBBY 123.0 BLDG. Ma. FREIGHT ELEVATOR 226.5 SALES SOFT. - EVATCR LOBBY 53.4 0 FS INTIMATE APC 1844.5 HOS0RY LE 1414 8 1474.8 FS LIME 1522.7 STOCK SOFT HOME 2671.50 STOCK CENTERCOF1E 360.0 0 SALES SJPT. FULFILLMENT CENTER 571.4 S SUP HALL 678.9 FS MSTYLE 15780 BLOC REO. TELEPHONE / ELECTRICAL 5/.4 FS 0 INTIMATE APPAREL 1659.1 SALES SJPT. VENAL OFFICES 148.1 BLDG. REO. DUCT / SHAF 0(00. RC 0 32.7 FS aulir ■ • UCr Q�=I� 5 ESCALATOR -i_ R�iii SU . AISLE ORCULATOXJ 493.7 F.R. 16101810 , 828.9Laikiylb41; I (SALES SUPT. J UNUSED / VOID SPACE 34,6 FS WOMEN'S SPORTSWEAR 2138.6 0 F5 WOMEN'S SPORTSWEAR 1883.7 0 SA 5 SUP . AISLE CIRCULAR 150.3 MEN'S SP 'NE 982.1 L BLDG. REO. DUCT / SHAFT 115.5 BLDG. REO. RESTROOM - MEN'S 192.8 0105. REQ. JANITOR CLOSET 54.2 FS OMEN'S SPORTSWEAR 2184.3 SALES SJPT. GENERAL OFFICES 1483 F.R. MENS 791.7 F.R. LADY TO WEAR 391.7 BLDG. REO. RESTROOM - WOMEN'S 142.1 BLDG. REQ. STAIRS 361.0 SALES SUPT. HALL 382.6 SALES SUPT. UNUSEO / VOD SPACE 54.3 SALES SUPT. GENERAL STORAGE 195.2 MSTYLE 1024.0 FS MEMS MILLENNIAL 1201.9 FS WOMEN'S SPORTSWEAR 2872.7 STOCK READY TO W 285.4 0 FS MEN'S MLLENNI 825.1 ES MEN'S 867.0 Lim'- MILLENNIAL FS CHLOREN'S 2040.1 SALES SUPT. FIXTURE STORAGE 286.4 FS MATERNITY 534.4 O FS CHLDREN'S �3yy13fl2 i, 0 FS CHIIGREN'S 765.1 FS MEMS MILLENNIAL 710.9 0 FS CHILDREN'S 1144.0 BLCG. REQ. STAIRS 397.7 SALES SUPT. HALL 75.0 SALES SUPT. HULL • 47.1 STOCK CENTERCCRE 202.1 FS INTIMATE APPAREL 371.0 F.R. READY TO WEAR 464.0 -SALES SOPT. UNUSED / VOID SPACE 22.5 SALES SUPT. UNUSED / VOID SPACE 110.4 BLDG. REQ. TELEPHONE / ELECTRICAL CLOSET 42.5 SALES OPT. HALL 406 SALES SLPT. STOCK-CENERAL OFFICES READY TO WEAR 102.1 551.0 SALES SUPT. NUS 0 / VOID SPACE 41.1 FS CHILDREN'S 2184.1 F.R. CHILDREN'S 740.9 .. z FAX HND Vt LCB FRS.. CENTRAL COLUMN LIP TO CENTRAL COLUMN/ ON 3R FLOOR TO LOCATION t7` DMARC<ON 3RD FL �L SALES SUPT. SPACE FIXTURE STORAGE 143.2 SALES SUPT. UNUSED / MIND SPACE 43.7 STICK CHILDREN'S 284.3 STOCK MENS 492.3 EXISTING FLOOR PLAN - BASEMENT FLOOR SCALE: V=40'-0' PLAN NORTH TRUE NORTH ppg04 4:153#0RF ROI/ -v0 QuiRFQ mpw bwr CITY OF TUKWILA MAY 18 2011 PERMIT CENTER SHEET DESCRIPTION MPE100 MECHANICAL, PLUMBING AND ELECTRICAL OVERALL BUILDING PLANS; SPECIFICATIONS H200 HVAC DEMOLITION AND NEW PLANS P200 PLUMBING PLANS AND RISERS El 00 ELECTRICAL DETAILS, SYMBOLS AND DEMOLITION PLAN E200 E300 ELECTRICAL LIGHTING, POWER AND LOW VOLTAGE PLANS ELECTRI �.ai_MITT.ISER DIA • ' M AND SCH DULES CM-MPE100-REV 0.0 ie* DESIGN & CONSTRUCTION MANAGEMENT: 0 4000 Luzottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 0 +1 (513) 765-6000 0 +1(516) 393-2484 Stare ##8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: 0 O L j O CD LE Up O C X O 2 - CU O .473� U cn X (./10 < CD 41( Macy's Store Number Revisions: Mark Date By 4/10/17 ST CLIENT COMMENTS A A A A Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review XIDOB Permit ❑ DOB Permit - Re -Submit ❑ LL Approval ® Bid 0 Construction Title OVERALL FLOOR PLAN - MEP SERVICES Date 04/06/2017 Drawn By STAFF Checked By MPR Sheet IVPE100 WALL ASSEMBLY (TYP.) HVAC DETAIL NOTE: VERIFY CEILING TYPE ON ROOM FINISH SCHEDULE. EGG CRATE TRANSFER GRILLE, SEE PLAN FOR SIZES. II II II II II II EGG CRATE TRANSFER GRILLE, SEE PLAN FOR SIZES. TRANSFER RETURN AIR DETAIL SCALE: NONE BALANCING DAMPER VARIES 2" MINIMUM COLLAR RECTANGULAR TO ROUND "BUCKLEY FITTING" BALANCING DAMPER (B) RECTANGULAR TO RECTANGULAR II II I SUPPORT TO STRUCTURE ABOVE (TYP.) 1" DUCT LINER LINE WITH 1" INSUL. GALVANIZED SHEET METAL DUCTWORK E7CEILING ECCENTRIC REDUCER BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION. BRANCH DUCT TAKE OFF DETAILS BALANCING DAMPER 45° LATERAL FITTING BALANCING DAMPER CONICAL FITTING SCALE: NONE VOLUME DAMPER TO BE WITHIN 12" OF MAIN DUCT ACOUSTICAL CEILING SUPPLY AIR DUCT, INSULATE PER SPEC. HIGH EFFICIENCY FITTING INSULATED RIGID ROUND DUCTWORK. INSULATION TO HAVE FOIL FACING (TYP.) INSULATED FLEX. DUCT (5 FEET MAX.) SHALL BE 1.5 x R, INSULATED 90 DEGREE SHEET METAL ELBOW AND (TYP. CEILING DIFFUSER HVAC DETAIL NOTES: 1. SEE HVAC DRAWINGS FOR DUCT SIZES C) DUCT CONNECTION DETAIL SCALE: NONE t 12"0 20x12 A B C SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY. OR AS NOTED RETURN AIR GRILLE ROUND DUCTWORK. DIAMETER IN INCHES. RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. DIFFUSER/GRILLE LABEL: A - TYPE/DESIGNATION B - NECK SIZE (INCHES) C - AIRFLOW (CFM) POINT OF CONNECTION - NEW TO EXISTING MANUAL VOLUME DAMPER SHEET KEYNOTE REFERENCE 1-LCM-H200-REV 0.0 TAG SERVICE MOUNTING MFR MODEL No. MODULE SIZE FINISH NOTES S1 SUPPLY AIR MATCH CEILING TITUS TMS 24" X 24" STD. WHITE FINISH 1 R1 RETURN AIR MATCH CEILING TITUS 50F 24" X 24" STD. WHITE FINISH R2 RETURN AIR MATCH CEILING TITUS 50F 12" X 24" STD. WHITE FINISH NOTES/ACCESSORIES 1. PROVIDE NECK SIZE TO MATCH SUPPLY DUCTWORK ON DRAWINGS. 2. TITUS CHOSEN, EQUALS ALLOWED. 3-LCM-H200-REV 0.0 DUCT SIZE CROSS REFERENCE CFM ROUND RECTANGULAR A. THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCE I. DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS. PRODUCTS, THE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES. IF 14X10 12X10 ALTERNATE MANUFACTURERS ARE SUBMITTED OR BID, IT IS THE RESPONSIBILITY OF THIS G.C. TO J. ALL DUCTWORK CONCEALED ABOVE CEILINGS, AND ALL OUTSIDE AIR DUCTS, SHALL BE EXTERNALLY COORDINATE ALL DIFFERENCES AND IMPACTS WITH ALL TRADES PRIOR TO BID, INCLUDING COSTS 16X8 INSULATED. IF DUCTWORK IS RUN IN A NON -CONDITIONED SPACE ALL DUCTWORK MUST BE ASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES. NO EXTRAS WILL BE ALLOWED FOR INSULATED WITH 2" FIBERGLASS INSULATION AND VAPOR BARRIER. CHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR INSTALLED AT THE 18X6 16X8 G.C.'S OPTION. K. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED. B. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD L. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS. WORK. THE G.C. SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL 14X8 12X8 COMPENSATION SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING M. G.C. MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIR CONDITIONS NOT AS INDICATED ON THE PLANS. 14X8 BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT. C. G.C. SHALL NOTIFY TENANT, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR N. IT IS THE G.C.'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL COMPONENTS ARE INSTALLED INCREASE THE SCOPE OF WORK FROM WHAT IS DESCRIBED IN THE DOCUMENTS. 16X6 AT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY AND SAFELY ACCESSIBLE FOR 12X8 10X8 ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. D. G.C. SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK. 10 14X6 12X6 0. THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND E. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM, CONSTRUCTION MATERIALS 250 SPECIFICATIONS. SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY G.C. ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE 12X6 OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70. CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE 8 12X6 BY THE G.C. IF WORK IS REQUIRED BY TENANT IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR F. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHT CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY 8 INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, G.C. SHALL BE SHOULD ANY CONFLICT ARISE. DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT 100 THE G.C. CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE G. MOUNTING OF ALL EQUIPMENT, DUCTWORK AND PIPING MUST BE DONE PER BUILDING GUIDELINES TENANT MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE G.C. FOR ANY AND LOCAL CODES AND INDUSTRY STANDARDS. COORDINATE INSTALLATION OF EQUIPMENT CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP SUPPORT WITH BUILDING MANAGER AND NEXTORE REPRESENTATIVE. AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS. H. NO PVC PIPING ALLOWED IN PLENUM AREAS. P. DUCTWORK SHALL NOT BE ROUTED OVER ELECTRIC PANELS AND TRANSFORMER. 2-LCM-H200-REV 0.0 DUCT SIZE CROSS REFERENCE CFM ROUND RECTANGULAR 600 12 18X8 16X8 14X10 12X10 550 12 18X6 16X8 14X8 12X10 500 12 18X6 16X8 14X8 12X10 450 12 18X6 16X6 14X8 12X8 10X10 400 10 16X6 14X8 12X8 10X10 350 10 16X6 14X6 12X8 10X8 300 10 14X6 12X6 10X8 250 10 14X6 12X6 10X6 8X8 200 8 12X6 10X6 8X8 150 8 8X6 8X8 100 6 6X6 75 6 MACY'S HALLWAY CLG. HT.=! 10'-0" CONTACT LENS 104 CLG. HT.= 10'-0" 0 I' 8" DIA 1. RETAIL AREA OPEN TO MACY'S HVAC SYSTEM. NO WORK REQUIRED IN THIS AREA. 2. EXISTING STORE SUPPLY AIR DUCTWORK TO REMAIN. 3. CONNECT NEW SUPPLY AIR DUCTWORK TO EXISTING STORE SUPPLY AIR DUCTWORK AS INDICATED. 4. PROVIDE DAMPERS PER DETAIL IN DESIGN MANUAL. PROVIDE CABLE OPERATED DAMPERS WHERE DAMPERS ARE INSTALLED OVER GYPSUM BOARD CEILING. 5. PROVIDE DUCT TAKE OFFS PER DETAIL. HIGH EFFICIENCY FITTINGS SHALL BE USED. SEE DETAIL IN DESIGN MANUAL 6. INSULATE ALL SUPPLY DUCTWORK PER APPLICABLE ENERGY/MECHANICAL CODE - MOST RESTRICTIVE TO GOVERN. 7. EXISTING SUPPLY DIFFUSER AND DUCTWORK TO REMAIN. 8. DISCONNECT AND RELOCATE EXISTING RETURN AIR GRILL TO NEW LOCATION. ADJUST RETURN DUCTWORK IF REQUIRED. 4-LCM-H200-REV 0.0 (TYP) (TYP) S-1 125 R-2 R-2 8" DIA 10" DIA �-•... DIA 8" DIA S_1 200 RETAIL SALES AREA OPTICAL STATION 103 CLG. HT.= 10'-0" PRETEST 102 CLG. HT.= 10'-0" HVAC PLAN SCALE: 1/4' = 1'-0' EXAM ROOM 101 CLG. HT.= 10'-0" 100 CLG. HT.= VARIES RECEIVED CITY OF TUKWILA MAY 18 2017 PERMIT CENTER DESIGN & CONSTRUCTION MANAGEMENT: ® 4000 Luxottica Place, Mason, OH 45040 6 Creamery BrookEast Granby, CT 06026 o ♦1(513)765-6000 ® i1 (516) 393-2494 Stare 4t8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: QO LLI O Ln � O ru- u0 LL Ox O J rt'3 CD 4— r6 � 440) c>3 CD Q cp 71- Macy's Store Number: Revisions: Mark Date By /i \ 4/10/17 ST CLIENT COMMENTS A` >, A A A Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review IX] DOB Permit ❑DOB Permit - Re -Submit O LL Approval E1 Bid ❑ Construction Title HVAC PLANS AND DETAILS Date 04/06/2017 Drawn By STAFF Checked By MPR Sheet H200 PLUMBING EQUIPMENT SCHEDULE GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS. MARK DESCRIPTION SUPPLIED/ INSTALLED BY MFG./ PHONE # MODEL # / COLOR REMARKS SK -3 ROUND SINK FOR CONTACT LENS T / PC JUST SINKS (847) 678-5150 SINK: CLF -ADA -10 FAUCET: JUST # J-981 0.5 GPM GC TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F. SK -7 30" SINK FOR BOH-SU30 T / PC ELKAY SINK: LLVR2117, STRAINER: 1135, FAUCET: DELTA 101 DST 0.5 GPM *SELECT 1 -HOLE DRILLING CONFIGURATION. G.C. TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F IF REQUIRED. IWH-1A IWH-1B TANKLESS WATER HEATER MOUNTED BELOW SINKS IN CABINET. PC / PC EEMAX MODEL #SP2412 SINGLE POINT, 120 VOLT, 1 PHASE, 60 HZ, 2.4 KW, 33° TEMPERATURE RISE. SINK AND FAUCET (SEE SCHEDULE) iHOT WATER SUPPLY TO SINK TANKLESS WATER HEATER (SEE SCHEDULE) COLD WATER SUPPLY TO SINK WATER SUPPLY SHUT OFF VALVE DRAIN FROM SINK (E) WATER HEATER PIPING SCHEMATIC SCALE: NONE EXIS. 6" BELOW SLAB l'\,z-1 1/2" 1 1/2" . SK3 l / 0A SANITARY & VENT ISOMETRIC / SCALE: NONE O (rWD 2\ I \ • 1 1/2" SK7 ;2" (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) 0 ELBOW UP O ELBOW DOWN TEE OUTLET UP 0/H DN U/G EX TEE OUTLET DOWN SANITARY PIPING (W) SANITARY VENT PIPING (V) COLD WATER (CW) HOT WATER (HW) OVERHEAD DOWN UNDERGROUND EXISTING 7 IC®► CAP ON END LINE WALL CLEANOUT WATER METER PLUMBING FIXTURES POINT OF NEW CONNECTION TO EXISTING PIPING OR SYSTEM VALVE 1-LCM-P200-REV 0.0 P.D.I. UNITS 0 FIXTURE UNITS 1-3 4-11 12-32 33-60 61-113 114-154 155-330 2-LCM-P200-REV 0.0 PLUMBING FIXTURE QTY. SAN F.U. EACH SAN F.U. TOTAL C.W F.U. EACH WTR. DMD. TOTAL SINK (SK3 & SK7) 2 2.0 4.0 2.0 4.0 TOTALS SERVICE CONNECTION SIZE 4.0 4.0 SAN. 2" WATER 3/4" 3-LCM-P200-REV 0.0 FIXTURE DRAIN HOT COLD VENT SINK 2" 1/2" 1/2" 1-1/2" ELECTRIC WATER HEATER 1/2" 1/2" NOTE: (SKI THRU 7) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS AND APPURTENANCES NECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS FURNISHED BY OWNER. 4-LCM-P200-REV 0.0 CONTACT LENS 104 MACY'S HALLWAY I•SK3 00 (TYP) CLG. HT.= 10'-0" 1. CONNECT TO EXISTING DOMESTIC WATER PIPE. G.C. TO COORDINATE WORK WITH LANDLORD FOR WATER TIE IN. SEE MPE-100 2. REFER TO DETAIL IN DESIGN MANUAL FOR WATER HEATER PIPING DETAIL. 3. CONTRACTOR SHALL RUN ALL PLUMBING PIPING CONCEALED. 4. EXISTING SPRINKLER HEAD TO REMAIN. 5. REMOVE EXISTING SPRINKLER HEAD. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLER CONTRACTOR AT THE GC'S EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUT NOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ETC., AS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS. 6. PROVIDE NEW SPRINKLER HEADS IN NEW ROOMS. ACTUAL LOCATIONS TO BE DETERMINED BY FIRE PROTECTION CONTRACTOR. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLER CONTRACTOR AT THE GC'S EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUT NOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ETC., AS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS. 6-LCM-P200-REV 0.0 / NEW ISOLATION VALVE CBD IWH-1B SUPPLY ISOMETRIC 1/2" 0 SK7 • 00 (TYP) MACY'S HALLWAY'' 104 CLG. HT.= .......................................... CONTACT LENS 104 CLG. HT.= 10'-0" SCALE: NONE 10'-0" OPTICAL STATION 103 CLG. HT.= 10'-0" (TYP) 1. EXTEND NEW SANITARY PIPE TO LOCATION INDICATED ON MPE-100 AND MAKE CONNECTION TO EXISTING SANITARY PIPE. 2. CONNECT NEW VENT TO EXISTING VENT MAIN IN LOCATION INDICATED ON MPE-100. 3. ALL PLUMBING PIPING TO BE CONCEALED. 4. THE CEILING IN THIS AREA ISA PLENUM. USE CODE MINIMUM PIPING TO CONNECT TO THE BUILDING SERVICES. 5-LCM-P200-REV 0.0 APPROXIMATE LOCATION OF 6" SANITARY BELOW SLAB 1O� 00 (TYP) 00 (TYP) SK7.: RETAIL SALES AREA DROP SANITARY TO BELOW SLAB AND TRENCH FLOOR AND MAKE CONNECTION TO EXISTING SANITARY LINE 0 (TYP) 0 PRETEST 102 CLG. HT.= 10'-0" EXAM ROOM SANITARY AND VENT PLAN SCALE: 1/4' =1'-0" 101 CLG. HT.= 10'-0" PLAN NORTH (TYP) 0 (TYP) SK7 100 CLG. HT.= VARIES RETAIL SALES AREA OPTICAL STATION 103 CLG. HT.= 10'-0" PRETEST 102 CLG. HT.= 10'-0" WATER SUPPLY AND FIRE PROTECTION PLAN SCALE: 1/4' = T-0' EXAM ROOM 101 CLG. HT.= 10'-0" PLAN NORTH SEPARATE PERMIT AND APPROVAL REQUIRED 100 CLG. HT.= VARIES RECEIVED CITY OF TUKWILA MAY 18 2017 PERMIT CENTER DESIGN & CONSTRUCTION MANAGEMENT: 0 4000 Luxottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 RE 0 +1 (513) 765-6000 0 +1(516)393-2484 Stare #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: Con CD O LUO Ln ,` 0 O (6� V O c N � V c>30 >3 � X � J l/1 imuQ O d 41( Macy's Store Number: Revisions: Mark Date By A4/10/17 ST CLIENT COMMENTS A A A A Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 EXPIRES 12-D9-17 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review ® DOB Permit ❑ DOB Permit - Re -Submit ❑ LL Approval ® Bid ❑ Construction Title SANITARY AND VENT PLANS AND DETAILS Date 04/06/2017 Drawn By STAFF Checked By MPR P200 OUTLINE OF RECESSED OUTLET BOX. SEE ARCH DWGS 6 1/2" 12" F z w ion io 5 0 w EQUIPMENT ELECTRICAUMECHANICAL REQUIREMENTS ID DESCRIPTION VOLT AMP BTU NOTES EQ6A LENSOMETER (AUTO) 120 1 X NEMA #5 - 20R DOUBLE DUPLEX, 20A RECEPTACLE 7 FED BY CIRCUIT #1 8 FED BY CIRCUIT #2 EQ109B REFRACTION STAND 120 2.1 X REQUIRES DATA EQ105C OCULUS 120 1.1 X EQ108 PATIENT CARE N/A 120 0.5 X THIS EQUIPMENT PLUGS INTO EQ100C EQUIPMENT IS NOT IN USE IN THIS PLAN. EQ100A OPTOS 120 3 X EQ119 KERATOMETER 120 2.1 X X EQ103 LENSOMETER 120 1 X EQUIPMENT IS NOT IN USE IN THIS PLAN. ELEVATION INSTALL RECESSED OUTLET AT 72" AFF TO CENTERLINE EQ11 > > 1 EQ108 V EQ109B PLAN REFRACTION (EXAM) ROOM ELECTRICAL INFORMATION SCALE: NONE V GS-CW20 EQ EQ 1 PASS THROUGH EQ EQ 111 ELEVATION EQ121 PLAN ELECTRICAL LEGEND 0 DESCRIPTION 1 MC CABLE, 12/2 w/GROUND, 12 AWG 2 MC CABLE, 12/3 w/GROUND, 12 AWG 3 4X4 JUNCTION BOX 4 SEAL-TITE FLEXIBLE CONDUIT WHIP FROM POKE THRU TO J -BOX. 5 DUPLEX 20A RECEPTACLE 6 DOUBLE DUPLEX, 20A RECEPTACLE 7 FED BY CIRCUIT #1 8 FED BY CIRCUIT #2 9 SINGLE GANG BOX WITHOUT A COVER FOR DATA (DATA WIRING BY OTHERS). 10 ONE INCH CONDUIT STUB FROM FLOOR BOX/POKE THROUGH WITH PULL STRING ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL ELECTRICAL EQUIPMENT SHOWN IN THE DETAILS. NO WORK IS PROVIDED BY THE CASEWORK MANUFACTURER. THE DATA CABLING IS THE ONLY WIRING NOT IN THE ELECTRICAL CONTRACTOR'S SCOPE. ALL POWER WIRING IS TO BE IN METAL RACEWAY. SECURE RACEWAY TO INSIDE OF FURNITURE. COORDINATE WORK WITH THE GC. CW2OW ELECTRICAL INFORMATION SCALE: NONE +• SE -0D03 43" SE -0D03 28" I , S'-OD01 L ELEVATION 13" f 0MSE 41" t GFI CI 0 — CONNECTION FOR TANKLESS WATER HEATER CLO2 ELECTRICAL INFORMATION SCALE: NONE 0 SE -0D03 SE -0D03 .1)_EQ6A SE -0D01 PLAN SE -0D01 DOCTOR'S DESK 0451 ELEC. INFO. SCALE: NONE PROVIDE IN WALL (2) i" CONDUIT FROM IN -WALL BOX TO 6" ABOVE CEILING. 0835-00 1'-3" 3'-4" 1 ©® 1'-9" 9 / LCGLB184200 ELECTRICAL INFORMATION SCALE: NONE SEE SHEET A100 FOR C.L. DIM. IN WALL: (2) ARLTVBU505BL - ARLINGTON' TVBU505BL TWO -GANG RECESSED ELECTRICAL BOX (BLACK) (OR EQUAL BLACK IN COLOR) CASEWORK ELECTRICAL (INSTALLED BY CASEWORK SUPPLIER) PW -10 (2) 92" LED STRIP 42W (1) 60W DRIVER TOTAL 42W PW -11 (1) 92" LED STRIP 21W (1) 60W DRIVER TOTAL 21W EQ101 TO LEDs IN CASEWORK. WIRING, DRIVER AND LEDs ARE INSTALLED BY CASEWORK SUPPLIER. ELECTRICAL OUTLET INSTALLED BY EC AT 15" AFF. TO LEDs IN CASEWORK. WIRING, DRIVER AND LEDs ARE INSTALLED BY CASEWORK SUPPLIER. ELECTRICAL OUTLET INSTALLED BY EC AT 15" AFF. CO GS-PWO1_R EC TO PLUG DRIVER INTO RECEPTACLE PW10/PW11 AND 0400/0420 ELECTRICAL INFORMATION SCALE: NONE EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTS ID DESCRIPTION VOLT AMP BTU NOTES EQ100C TRIPLE POWER TABLE 120 1 X THIS TABLE PLUGS INTO THE WALL EQ101 TONOMETER 120 1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ102 REFRACTOMETE RI 20 1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ105C OCULUS 120 1.1 X THIS EQUIPMENT PLUGS INTO EQ100C EQ104 VISION TESTER 120 0.5 X THIS EQUIPMENT PLUGS INTO EQ100C EQUIPMENT IS NOT IN USE IN THIS PLAN. (6' PRETEST ELECTRICAL INFORMATION SCALE: NONE ELECTRICAL CONTRACTOR TO PROVIDE ONE 20A, 120V UNSWITCHED CIRCUIT TO ONE (1) DUPLEX RECEPTACLE AND (1) QUAD RECEPTACLE. ELECTRICAL CONTRACTOR TO PROVIDE RACEWAY AND BOX FOR DATA OUTLET. BACKWRAP 0821 ELECTRICAL INFORMATION SCALE: NONE 1. DISCONNECT AND REMOVE EXISTING TRACK AND FIXTURE AND RETURN TO MACY'S OPERATIONS. 2. DISCONNECT AND RELOCATE EXISTING 2X2 FIXTURE TO NEW LOCATION AND RECONNECT TO EXISTING. SWITCHING MEANS. 3. DISCONNECT AND REMOVE EXISTING 2' X 2' LIGHT FIXTURE AND RETURN TO MACY'S OPERATIONS. 4. DISCONNECT AND REMOVE EXISTING WALL WASH FIXTURE AND RETURN TO MACY'S OPERATIONS. 5. DISCONNECT AND REMOVE EXISTING RECESSED ADJUSTABLE LIGHT AND RETURN TO MACY'S OPERATIONS. 6. DISCONNECT AND REMOVE EXISTING STRIP FIXTURE AND RETURN TO MACY'S OPERATIONS. 7. EXISTING LIGHT FIXTURE IS TO REMAIN. 8. EXISTING SPEAKER TO REMAIN. 9. DISCONNECT AND REMOVE EXISTING SPEAKER AND TURN OVER TO MACY'S OPERATIONS. 10. DISCONNECT AND REMOVE EXISTING RECEPTACLE. RECONNECT DEVICES TO REMAIN. 11. EXISTING CEILING MOUNTED FIRE ALARM DEVICE TO REMAIN. 12. EXISTING SECURITY CAMERA TO REMAIN. 2-LCM-E100-REV 0.0 EX/A EX/A 0�I O II I IEX/A I 0 MEE O DESIGN & CONSTRUCTION MANAGEMENT: ® 4000 luxottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 RE 0 +1(513)765-6000 0 .1(516)393-2484 Stare 4t8932 SOUTHCENTER 500 SOUTHCENTER WALL TUKWILA, WA 98188 Construction for: W LL (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) HOMERUN TO PANEL AND CIRCUIT INDICATED XX-## �PANELCIRCUIT — INFLOOR/UNDERFLOOR CONDUIT/WIRE JUNCTION BOX DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED: "2" INDICATES CIRCUIT NUMBER "E" EXISTING TO REMAIN "WP" INDICATES WEATHERPROOF COVER "D" DEDICATED CIRCUIT "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE "R" INDICATES RECESSED "TR" TAMPER RESISTANT DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. "CLG" INDICATES MOUNTED IN CEILING COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. COMMUNICATIONS FLOOR BOX SWITCH - SINGLE POLE TOGGLE TYPE -120/277 VOLT, 1 -HP RATED, 20 AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED: "3" INDICATES THREE WAY SWITCH "4" INDICATES FOUR WAY SWITCH "C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER "OS" INDICATES OCCUPANCY SENSOR SWITCH "D" INDICATES 0-10V DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR "M" INDICATES A MASTER SWITCH THAT OVERRIDES THE OTHER SWITCHES CONNECTED TO IT. "OSD"INDICATES 0-10V DIMMER SWITCH WITH INTEGRAL PIR OCCUPANCY SENSOR - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR. 1 OR 3 WAY AS INDICATED. CEILING MOUNTED OCCUPANT SENSOR I LIGHT FIXTURE: "AD" INDICATES FIXTURE TYPE "a" INDICATES a SWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. TL #T -S VARY - SEE PLANS) OD TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS. ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. LIGHTING TIME CLOCK DATA OUTLET: MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. 'W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. CLG INDICATES CEILING MOUNTED. V2 2 PORT DATA OUTLET V4 4 PORT DATA OUTLET V3 3 PORT DATA OUTLET V6 6 PORT DATA OUTLET SWITCHED WIRING BRANCH CIRCUIT WIRING HOMERUN MOTOR FIRE ALARM DEVICES ARE ONLY SHOWN FOR PREFERENTIAL LOCATION. FINAL LOCATIONS AND QUANTITIES SHALL BE DETERMINED BY LL AND FIRE ALARM ENGINEER- VERIFY PRIOR TO ROUGH IN. �F FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF. • FIRE ALARM AUDIONISUAL ALARM SIGNAL CEILING MOUNTED. FIRE ALARM VISUAL ONLY ALARM SIGNAL CEILING MOUNTED. O FIRE ALARM SMOKE DETECTOR ®— FIRE ALARM SMOKE DETECTOR - DUCT MOUNTED 1-LCM-E100-REV 0.0 EX/A r --I ILwA I EX/A 0 Mil ® EX/A SP 0 0 • NNIMNINNIONNINII EX/A 0 V EX/A 0 0 ELECTRICAL DEMOLITION PLAN SCALE: 1/4' = T -0 - • EX/A 0 PERMIYE T APPROV RE .�a RECEIVED CITY OF TUKWI MAY 18 2017 PLA NORTH PERMIT CENTER U z Lu QO O LnO (>3 � V0 C) c X O D co - N � V O ra CL 70 o � J CD <C O Macy's Store Number: Revisions: Mark A Date By 4/10/17 ST CLIENT COMMENTS A A A A Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review IBI DOB Permit ❑DOB Permit - Re -Submit ❑ LL Approval El Bid ❑ Construction Title ELECTRICAL DETAILS, SYMBOLS, AND DEMOLITION Date 04/06/2017 Drawn By STAFF Checked By MPR Sheet E100 0 v: AN EXISTING FIRE ALARM SYSTEM WITH NOTIFICATION APPLIANCES IS NOT PRESENT. NOTIFICATION APPLIANCES ARE NOT BEING PROVIDED FOR THE NEW LENSCRAFTERS SPACE. AN EXISTING FIRE ALARM SYSTEM WITH NOTIFICATION APPLIANCES IS PRESENT. NOTIFICATION APPLIANCES ARE BEING PROVIDED FOR THE NEW LENSCRAFTERS SPACE. A. ELECTRICAL CONTRACTOR TO PROVIDE ALL RACEWAY AND BOXES AND A 120V SUPPLY TO THE FIRE ALARM POWER EXTENDER. B. TENANT WILL CONTRACT DIRECTLY WITH MACY'S REQUIRED CONTRACTOR FOR DEVICES, WIRING, AND PROGRAMMING. C. FIRE ALARM SUBMITTAL WILL BE PROVIDED TO THE JURISDICTION FROM THE MACY'S FIRE ALARM VENDOR AS A DEFERRED SUBMITTAL UNDER A SEPARATE PERMIT. FIRE ALARM VENDOR IS: TYCO, CONTACTS: JESSICA JONES (JRJONES@TYCO.COM; 1-800-453-2247 EXT 5116) 4-LCM-E100-REV 0.0 CURRENT LIMITING END FEED END FEED USED IN REVERSE TO SUPPLY NEXT TRACK SECTION WHEN TRACK IS SEPARATED, AND TO SUPPLY MONOPOINT FIXTURES. END FEED TO SUPPLY END FEED TO SUPPLY TRACK SECTION. TRACK SECTION. TRACK SECTION (A) TRACK SECTION TO MONOPOINTS TRACK WIRING DETAIL TRACK SECTION END FEED USED IN REVERSE TO SUPPLY NEXT TRACK SECTION WHEN TRACK IS SEPARATED, AND TO SUPPLY MONOPOINT FIXTURES. SCALE: NONE 0C FLOOR BOX SCHEDULE / SCALE: NONE EX/A AD (TYP) EX/A EX/A _LCI-UH1Il _ CURRENT LIMITER TO RESTRICT TO 720W A-20 8T -S EX/A ENERGY CODE - COMMISSIONING 1. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA: 1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. 1.2. LOCAL SWITCHING IS DIMMABLE, ALLOWING A RANGE OF DIMMING FROM 5% TO 100%. 1.3. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY. 2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: 2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND DE -ENERGIZED WITH THE MACY'S DISPLAY LIGHTING CONTROL. 2.2. SUPPLEMENTAL TRACK LIGHTING IS LIMITED TO 125% OF THE CONNECTED WATTAGE OF TRACK HEADS. 2.3. SUPPLEMENTAL TRACK LIGHTING IS CONTROLLED WITH THE MACY'S ACCENT LIGHTING CONTROL. LIGHT M/OS D DIMMER. SUPPLIED BY TENANT 0-10V, 1-WAY/3-WAY, WHITE OCCUPANCY SENSOR WALL SWITCH (SUPPLIED BY TENANT) OPERATES AS MASTER. — — — — UNSWITCHED CIRCUIT WALL SENSOR/DIMMER/MASTER SWITCH COMBINATION LIGHT r- OSD OSD: OCCUPANT SENSING DIMMER. SUPPLIED BY TENANT, 0-10V, 1-WAY/3-WAY, WHITE L — UNSWITCHED CIRCUIT WALL SENSOR/DIMMER COMBINATION NOTE: ALL WIRING BY THE ELECTRICAL CONTRACTOR. OCCUPANCY SENSOR SCHEMATICS SCALE: NONE COIL LOAD DESCRIPTION CIRCUIT CONNECT TO NEAREST MACY'S 120V MERCHANDISE LIGHTING CIRCUIT SWITCHED WITH MACY'S LIGHTING CONTROL SYSTEM. CASEWORK AND SIGNS �� SEE PLANS WALL SHELF LIGHTING —III-- SEE PLANS CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. CONNECT TO NEAREST MACY'S 120V SALES FLOOR ACCENT LIGHTING CIRCUIT SWITCHED WITH MACY'S LIGHTING CONTROL SYSTEM. NOTE WHERE ACCENT LIGHTING IS 277V, USE LOAD DESCRIPTION I CIRCUIT A 277V COIL. SUPPLEMENTAL SALES LIGHTING --III--- SEE PLANS CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD, IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD. VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS. MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY). TL TL TL TL TL TL TL TL CONNECTION TO BUILDING AUTOMATION SYSTEM SCALE: NONE EX/A EX Q RETAIL SALES AREA 100 CLG. HT.= VARIES 2T -S 4T -S 12T -S _ LCI-GH30 ••-/LC GH30 TL TL EX/A TL TL TL TL EXAM ROOM Tn N CONTACT LENS PRETEST CLG. HT.= 10'-0" CLG. HT.= 10'-0" CLG. HT.= 10'-0" OPTICAL STATION CLG. HT.= 10'-0" LIGHTING PLAN PLAN NORTH A. T SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. D. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. E. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA. G. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. H. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. I. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES -48", ELECTRICAL/TELEPHONE/DATA OUTLETS -18", TOP OF PANELBOARDS-6'-6", TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE. J. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0" K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. L. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM (WITH -IN 10%). M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. O. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. P. SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. Q. PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. 3-LCM-E100-REV 0.0 s.c. EX RETAIL SALES AREA 100 CLG. HT.= VARIES 21'-82" 1 A-3 8r -err o6J (TYP) 1. PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A, 120V, SINGLE PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR. 2. PROVIDE TRENCHING FOR POWER AND TELE/DATA TO SELECT TABLE. E.C. SHALL VERIFY ALL TRENCHING REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 3. PROVIDE "FURNITURE" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL AND THE DATA INTERCONNECTION RISER. 4. PROVIDE JUNCTION BOX AND CIRCUIT FOR EYE EXAM SIGN. 5. PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN. 6. VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 7. CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE DETAIL. VERIFY SPECIFIC REQUIREMENTS WITH MACY'S. 8. PROVIDE RECESSED RECEPTACLE AT ELEVATION SHOWN ON ARCHITECTURAL SHEETS FOR POWER TO DIGITAL EYE CHART. 9. ROUTE ONE 3/4" CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED AT HEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING. 10. ROUTE CONDUIT 6" ABOVE CEILING AND BUSH END. TYPICAL. 11. ROUTE ONE 1" CONDUIT FOR POWER AND TWO 1" CONDUITS FOR DATA. SEE DATA INTERCONNECTION RISER. PROVIDE PULL STRING. TYPICAL. 12. RECEPTACLE AND DATA OUTLET SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS. VERIFY EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 13. CASEWORK TO BE FIELD WIRED BY ELECTRICAL CONTRACTOR. SEE DETAIL. 14. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE CONDUCTOR AND THE RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED. 15. SEE DATA RISER DIAGRAM FOR ARRANGEMENT OF OUTLETS FOR THE DATA CABINET. 16. INSTALL OUTLET AT BACKWRAP FOR FRAME WARMER. VERIFY LOCATION OF OUTLET WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 2-LCM-A200-REV 0.0 1. SUPPLEMENTAL SALES FLOOR LIGHTING IS TO BE CONTROLLED BY THE MACY'S TIMECLOCK SYSTEM. 2. LIGHTING IN THIS AREA IS FROM MACY'S STORE. 3. LOCATION OF LIGHTING CONTACTORS. INSTALL ABOVE THE CEILING WHERE PERMITTED BY CODE. SEE DETAIL. 4. PROVIDE CURRENT LIMITER FOR TRACK FROM MANUFACTURER'S SELECTION, SIZED AS INDICATED. FINISH OF CURRENT LIMITER TO MATCH TRACK FINISH. 5. EXISTING LIGHTING FIXTURE IN NEW LOCATION. SEE DEMOLITION PLAN FOR MORE INFORMATION. 3-LCM-A200-REV 0.0 48" AFF A-21 SEE DATA INTERCONNECTION RISER ON E300 FOR ADDITIONAL INFORMATION. A-19 13 V III —111- :.-- -- A-18 A-18 I11►1.,:'HT1® A-3 Ex® EX DESIGN & CONSTRUCTION MANAGEMENT: .4000 Luxottica Place, Mason, OH 45040 6 Creamery Brook, East Granby, CT 06026 RE +1(513)765-6000 •+1(516) 393-2484 Store #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: O O LI= co Ii , p 1011= O O N a-� V O XJ5171 O UziQ cD =isi Macy's Store Number: Revisions: Mark Date By A4/10/17 ST CLIENT COMMENTS A A A A Engineer of Record Seal Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 TRRZY A-6 2 . C.` P P 0 *AA 004 LOAD CENTER "A" O (TYP) PRETEST INSTALL ABOVE COUNTER EXAM ROOM CONTACT LENS CLG. HT.= 10'-0" CLG. HT.= 10'-0" CLG. HT.= 10'-0" OPTICAL STATION RECEIVED CITY OF TUKWILA MAY 182017 PERMIT CENTER CLG. HT.= 10'-0" POWER AND LOW VOLTAGE PLAN ERAR M! (EXPIRES 12-09-17 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 REQUIRED . PLAN NORTH EQUIRED Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review ® DOB Permit 0 DOB Permit - Re -Submit ❑ LL Approval EI Bid 0 Construction Title LIGHTING, POWER AND LOW VOLTAGE PLANS Date 04/06/2017 Drawn By SCALE: 1/4' = SCALE: 1/4' = 1-0' STAFF ked By MPR Sheet E200 BOX CALL OUT ON PLANS RECESSED RECESSED FURNITURE POKE THRU FITTING IMMIMINIMI WIREMOLD EVOLUTION SERIES d 6AT POKE THRU 01111011=111111111 d S1PTFIT POKE THRU FLOOR BOX O SYSTEMONE FLOOR BOX HUBBELL CFBSIR4PFB W/CUP O SYSTEMONE FLOOR BOX HUBBELL SIPFB SUB PLATES 0ISI SYSTEMONE SUB -PLATE S1R4SP2X2DUPLEX TWO RECEPTACLES ONE DUPLEX AND DATA OUTLET °m SYSTEMONE SUB -PLATE HUBBELL S1SPFFAL COVER/ FLANGE *I CFBS1R4CVRALU (CARPET) 6CTC2AL (CARPET) I 6CT2AL (TILE) 0C FLOOR BOX SCHEDULE / SCALE: NONE EX/A AD (TYP) EX/A EX/A _LCI-UH1Il _ CURRENT LIMITER TO RESTRICT TO 720W A-20 8T -S EX/A ENERGY CODE - COMMISSIONING 1. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA: 1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. 1.2. LOCAL SWITCHING IS DIMMABLE, ALLOWING A RANGE OF DIMMING FROM 5% TO 100%. 1.3. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY. 2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: 2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND DE -ENERGIZED WITH THE MACY'S DISPLAY LIGHTING CONTROL. 2.2. SUPPLEMENTAL TRACK LIGHTING IS LIMITED TO 125% OF THE CONNECTED WATTAGE OF TRACK HEADS. 2.3. SUPPLEMENTAL TRACK LIGHTING IS CONTROLLED WITH THE MACY'S ACCENT LIGHTING CONTROL. LIGHT M/OS D DIMMER. SUPPLIED BY TENANT 0-10V, 1-WAY/3-WAY, WHITE OCCUPANCY SENSOR WALL SWITCH (SUPPLIED BY TENANT) OPERATES AS MASTER. — — — — UNSWITCHED CIRCUIT WALL SENSOR/DIMMER/MASTER SWITCH COMBINATION LIGHT r- OSD OSD: OCCUPANT SENSING DIMMER. SUPPLIED BY TENANT, 0-10V, 1-WAY/3-WAY, WHITE L — UNSWITCHED CIRCUIT WALL SENSOR/DIMMER COMBINATION NOTE: ALL WIRING BY THE ELECTRICAL CONTRACTOR. OCCUPANCY SENSOR SCHEMATICS SCALE: NONE COIL LOAD DESCRIPTION CIRCUIT CONNECT TO NEAREST MACY'S 120V MERCHANDISE LIGHTING CIRCUIT SWITCHED WITH MACY'S LIGHTING CONTROL SYSTEM. CASEWORK AND SIGNS �� SEE PLANS WALL SHELF LIGHTING —III-- SEE PLANS CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. CONNECT TO NEAREST MACY'S 120V SALES FLOOR ACCENT LIGHTING CIRCUIT SWITCHED WITH MACY'S LIGHTING CONTROL SYSTEM. NOTE WHERE ACCENT LIGHTING IS 277V, USE LOAD DESCRIPTION I CIRCUIT A 277V COIL. SUPPLEMENTAL SALES LIGHTING --III--- SEE PLANS CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD, IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING WHERE PERMITTED BY CODE. GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD. VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS. MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY). TL TL TL TL TL TL TL TL CONNECTION TO BUILDING AUTOMATION SYSTEM SCALE: NONE EX/A EX Q RETAIL SALES AREA 100 CLG. HT.= VARIES 2T -S 4T -S 12T -S _ LCI-GH30 ••-/LC GH30 TL TL EX/A TL TL TL TL EXAM ROOM Tn N CONTACT LENS PRETEST CLG. HT.= 10'-0" CLG. HT.= 10'-0" CLG. HT.= 10'-0" OPTICAL STATION CLG. HT.= 10'-0" LIGHTING PLAN PLAN NORTH A. T SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. D. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. E. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA. G. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. H. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. I. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES -48", ELECTRICAL/TELEPHONE/DATA OUTLETS -18", TOP OF PANELBOARDS-6'-6", TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE. J. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0" K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. L. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM (WITH -IN 10%). M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. O. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. P. SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. Q. PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. 3-LCM-E100-REV 0.0 s.c. EX RETAIL SALES AREA 100 CLG. HT.= VARIES 21'-82" 1 A-3 8r -err o6J (TYP) 1. PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A, 120V, SINGLE PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR. 2. PROVIDE TRENCHING FOR POWER AND TELE/DATA TO SELECT TABLE. E.C. SHALL VERIFY ALL TRENCHING REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 3. PROVIDE "FURNITURE" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL AND THE DATA INTERCONNECTION RISER. 4. PROVIDE JUNCTION BOX AND CIRCUIT FOR EYE EXAM SIGN. 5. PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN. 6. VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 7. CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE DETAIL. VERIFY SPECIFIC REQUIREMENTS WITH MACY'S. 8. PROVIDE RECESSED RECEPTACLE AT ELEVATION SHOWN ON ARCHITECTURAL SHEETS FOR POWER TO DIGITAL EYE CHART. 9. ROUTE ONE 3/4" CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED AT HEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING. 10. ROUTE CONDUIT 6" ABOVE CEILING AND BUSH END. TYPICAL. 11. ROUTE ONE 1" CONDUIT FOR POWER AND TWO 1" CONDUITS FOR DATA. SEE DATA INTERCONNECTION RISER. PROVIDE PULL STRING. TYPICAL. 12. RECEPTACLE AND DATA OUTLET SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS. VERIFY EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 13. CASEWORK TO BE FIELD WIRED BY ELECTRICAL CONTRACTOR. SEE DETAIL. 14. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE CONDUCTOR AND THE RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED. 15. SEE DATA RISER DIAGRAM FOR ARRANGEMENT OF OUTLETS FOR THE DATA CABINET. 16. INSTALL OUTLET AT BACKWRAP FOR FRAME WARMER. VERIFY LOCATION OF OUTLET WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. 2-LCM-A200-REV 0.0 1. SUPPLEMENTAL SALES FLOOR LIGHTING IS TO BE CONTROLLED BY THE MACY'S TIMECLOCK SYSTEM. 2. LIGHTING IN THIS AREA IS FROM MACY'S STORE. 3. LOCATION OF LIGHTING CONTACTORS. INSTALL ABOVE THE CEILING WHERE PERMITTED BY CODE. SEE DETAIL. 4. PROVIDE CURRENT LIMITER FOR TRACK FROM MANUFACTURER'S SELECTION, SIZED AS INDICATED. FINISH OF CURRENT LIMITER TO MATCH TRACK FINISH. 5. EXISTING LIGHTING FIXTURE IN NEW LOCATION. SEE DEMOLITION PLAN FOR MORE INFORMATION. 3-LCM-A200-REV 0.0 48" AFF A-21 SEE DATA INTERCONNECTION RISER ON E300 FOR ADDITIONAL INFORMATION. A-19 13 V III —111- :.-- -- A-18 A-18 I11►1.,:'HT1® A-3 Ex® EX DESIGN & CONSTRUCTION MANAGEMENT: .4000 Luxottica Place, Mason, OH 45040 6 Creamery Brook, East Granby, CT 06026 RE +1(513)765-6000 •+1(516) 393-2484 Store #8932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: O O LI= co Ii , p 1011= O O N a-� V O XJ5171 O UziQ cD =isi Macy's Store Number: Revisions: Mark Date By A4/10/17 ST CLIENT COMMENTS A A A A Engineer of Record Seal Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 TRRZY A-6 2 . C.` P P 0 *AA 004 LOAD CENTER "A" O (TYP) PRETEST INSTALL ABOVE COUNTER EXAM ROOM CONTACT LENS CLG. HT.= 10'-0" CLG. HT.= 10'-0" CLG. HT.= 10'-0" OPTICAL STATION RECEIVED CITY OF TUKWILA MAY 182017 PERMIT CENTER CLG. HT.= 10'-0" POWER AND LOW VOLTAGE PLAN ERAR M! (EXPIRES 12-09-17 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 REQUIRED . PLAN NORTH EQUIRED Brand Design Type: LCM MODULAR ISSUED FOR: ❑Client Review ® DOB Permit 0 DOB Permit - Re -Submit ❑ LL Approval EI Bid 0 Construction Title LIGHTING, POWER AND LOW VOLTAGE PLANS Date 04/06/2017 Drawn By SCALE: 1/4' = SCALE: 1/4' = 1-0' STAFF ked By MPR Sheet E200 1080 2760 4075 .. ... . ,v+ .... :.. � t.. r ,:,-: ,. ..v f• � ,.., t".::, , '".. .,: ., v , ..,. . x -;:.. f y z5 _} }. .,. 'i. . ✓ x.,. 3 Lia �� . ... a. ��. � �'. ,.::,. � ,u ✓d . > <. « fl,..... s, ..,. <: ,.. ,, n,.3 9 .s,.z .... ,. .h ...: i ,.3,. it ..- .:. ...,:>., SYMBOL TYPE MANUFACTURER PART -NUMBER INPUT WATTS LAMP QTY LAMP TYPE DESCRIPTION MOUNTING CEILING TYPE 02 TO CASH DESK 32 AD METALUX 22ALNG-LD4-35-UNV-L835-CD1- U-OCC/DIMMER (TOTAL QTY AS NOTED IN SCHEDULE NOTE #2) 03 34.5 N/A INTEGRAL LED, 3482 LUMENS RECESSED 2X2 LED TROFFER SUPPLIER TO PROVIDE OCC SENSORS, COMBINATION SENSORS/DIMMERS, AND 0-10V DIMMERS, WHITE IN COLOR, WITH FIXTURE PACKAGE. SEE NOTE #2 AT BOTTOM OF SCHEDULE RECESSED ACT AD 34 UNUSED 64 VOICE SERVICE AD- EM METALUX 22ALNG-LD4-35-UNV-L835-CD1-U -EL14W UNUSED 34.5 N/A INTEGRAL LED, 3482 LUMENS 14W EMERGENCY -1400 LUMEN RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY BACKUP. RECESSED ACT AD -EM ®X2 X2 LIGHT ALARMS SPLEDWRCD DATA SERVICE 3 N/A LED INCLUDED RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING OR WALL MOUNTING RED LED INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC OR CHICAGO CONFIRM WITH MANUF). PROVIDE CURRENT LIMITER WHERE REQUIRED. 42 VOICE SERVICE (SPLIT PAIR) X2/EM UyJ X2/EM LIGHT ALARMS UQLXN500-R-2LED-R 43 4 N/A LED INCLUDED SURFACE EXIT SIGN, POLYCARBONATE, RED LETTERS, 2 LED 3.6V, 4W HEADS INTEGRAL WITH UNIT AND CAPACITY TO ADD A SINGLE REMOTE HEAD. UNUSED 44 DY/EM/FT Y/EM/FT LIGHT ALARMS CAM -SD -OW -FT -H UNUSED 18 N/A LED INCLUDED EXTERIOR RATED LED EMERGENCY FIXTURE, OFF WHITE FINISH, FORWARD THROW, NORMALLY OFF, ON DURING POWER FAILURE, INTEGRAL BATTERY 16 UNUSED Y/EM Y/EM LIGHT ALARMS CAM -SD -OW -H 21 18 N/A LED INCLUDED EXTERIOR RATED LED EMERGENCY FIXTURE, OFF WHITE FINISH, NORMALLY OFF, ON DURING POWER FAILURE, INTEGRAL BATTERY UNUSED 22 0 D45 D45 CONTECH RA6LNC635K12D2/CST6322L2-CLR UNUSED 44.3 N/A INTEGRAL LED, 2708 LUMENS RECESSED LED DOWNLIGHT, CLEAR SPECULAR REFLECTOR, 3500K, 45W NOMINAL, 44.3 W LISTED, 0-10V DIMMING/NON-DIMMING RECESSED ACT 9 TL2 TL2 JUNO MONOPOINT TRAC-MASTER T40F-WH 84 - _ FLUSH MONOPOINT FITTING FLUSH MONOPOINT FITTING, WHITE UNUSED 85 JUNO LAMP HEAD T690WH VOICE SERVICE 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE MONOPOINT F F LITHONIA MNSL M6 24 N/A LED INCLUDED SURFACE STRIP, 24W MAX, 15W MIN, 4000K SURFACE - r 1 PD4 PD4 ET2 CONTEMPORARY LTG E22278-75PC 8 8 INTEGRAL WITH FIXTURE DECORATIVE 8 LIGHT PENDANT PENDANT GYP OR ACT 2T -S 9 TL 2T -S JUNO T2WH - _ TRACK ONLY - SEE TRACK HEAD 2 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE TRACK SEE FOOTNOTE 1 4T4T 4T -S JUNO T4WH - - TRACK ONLY - SEE TRACK HEAD 4 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE TRACK SEE FOOTNOTE 1 ii 6T -S 6T -S JUNO T6WH TRACK ONLY - SEE TRACK HEAD 6 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE TRACK SEE FOOTNOTE 1 BT -s TL 8T -S JUNO T8WH - - TRACK ONLY - SEE TRACK HEAD 8 FT LONG, SINGLE CIRCUIT, WHITE TRACK TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE TRACK SEE FOOTNOTE 1 12T -S 12T -S JUNO T12WH - - TRACK ONLY - SEE TRACK HEAD 12 FT LONG, SINGLE CIRCUIT, WHITE TRACK S TL TL JUNO T690WH 18 1 GE LED18D38W3930/25; 18W; 92 CR1; 3000K; PAR38, MED BASE GIMBAL STYLE LAMP -HOLDER, WHITE TRACK SEE FOOTNOTE 1 FOOTNOTES: 1. SEE PLANS FOR TRACK LOCATIONS. PROVIDE CURRENT LIMITERS AND PENDANTS WHERE CALLED FOR ON THE PLANS. 2. SUPPLIER TO PROVIDE 0-10V DIMMERS WITH FIXTURE PACKAGE. SEE PLANS FOR EXACT QUANTITIES. DIMMERS TO BE INSTALLED BY ELECTRICAL CONTRACTOR 1-LCM-A200-REV 0.0 TO MACY'S POS ROOM TO MACY'S PHONE ROOM TO MACY'S PHONE ROOM TO MACY'S DATA ROOM TO MACY'S PHONE ROOM CENTER OUTLETS BEHIND CABINET, LINE UP WITHIN AN 15" HORIZONTAL SPACE, BEHIND CABINET ACCESS OPENING TO BACKWRAP INSTALL OUTLETS AT 24" AFF TO CENTERLINE. ® El a 0 00 00 0 00 00 m LABINET IN OPTICAL STATION r 111® ®tom E MINI SERVER NEEDS TO GO INTO THIS CABINET. J ® 5 -- ASH DESK ON SALES FLOOR LENSCRAFTERS' NETWORK J NOTE: ALL COMMUNICATIONS WIRING AND JACKS ARE SUPPLIED AND INSTALLED BY OWNER'S VENDOR. GC TO PROVIDE RACEWAY SYSTEM ONLY. DATA INTERCONNECTION RISER SCALE: NONE DATA LABELING SCHEME - ONE DOOR STATE LABEL DESCRIPTION LABEL DESCRIPTION LABEL DESCRIPTION INFO 1.25 INFO 1.84 INFO 0.00 01 DATA SERVICE 31 DOCTOR'S PHONE SERVICE (SPLIT PAIR) 61 UNUSED 02 TO CASH DESK 32 DOCTOR'S PHONE SERVICE (SPLIT PAIR) 62 DATA LINE TO OPTOS 03 TO CASH DESK 33 UNUSED 63 VOICE LINE TO OPTOS 04 VOICE SERVICE 34 UNUSED 64 VOICE SERVICE 05 TO BACKWRAP DIGITAL SIGN 35 UNUSED 65 UNUSED 06 UNUSED 36 UNUSED 66 UNUSED 11 UNUSED 41 DATA SERVICE 71 DATA LINE TO OPTOS 12 UNUSED 42 VOICE SERVICE (SPLIT PAIR) 72 UNUSED 13 UNUSED 43 VOICE SERVICE (SPLIT PAIR) 73 UNUSED 14 UNUSED 44 DATA SERVICE 74 VOICE LINE TO OPTOS 15 UNUSED 45 VOICE SERVICE 75 UNUSED 16 UNUSED 46 UNUSED 77 UNUSED 21 TO BOH CABINET 51 UNUSED 81 UNUSED 22 TO BOH CABINET 52 UNUSED 82 UNUSED 23 DATA SERVICE 53 UNUSED 83 UNUSED 24 VOICE SERVICE 54 UNUSED 84 2ND REFRACTION/EXAM ROOM WHERE USED 25 VOICE SERVICE 55 UNUSED 85 UNUSED 26 VOICE SERVICE 56 UNUSED 88 UNUSED Dl 5 El OPTOS tI TO MACY'S PHONE ROOM (1 DOOR STATE) REFRACTION/EXAM ROOM. OPTOMETRIST NETWORK - ONE DOOR STATE ® Ei BELOW COUNTER IN OPTICAL WORK STATION TO MACY'S PHONE ROOM FOR DOCTOR'S PHONE O KEY NOTES : 1. UTILIZE EXISTING PANEL FOR THE 60A FEED TO NEW LOAD CENTER "A" IN THE LENCRAFTER'S SPACE. VERIFY CURRENT LOAD ON EXISTING PANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. 2. CONTRACTOR TO VERIFY IF PANEL ELI IS CONTROLLED BY A CONTACTOR. IF SO, CONTRACTOR TO INVESTIGATE ADJACENT PANEL(S) AND IF AN UNSWITCHED SOURCE CAN NOT BE OBTAINED, INSTALL A 60A ENCLOSED BREAKER TAPING THE INCOMING CONDUCTORS OF PANEL ELI. -.r MACY'S ELECTRIC ROOM (4)#6, (1)#8 GND IN 1 1/4" C. WHERE PERMITTED BY THE JURISDICTION AND LANDLORD, MC CABLE CAN BE USED FOR THIS INSTALLATION. LENSCRAFTERS SW NEW PANEL "A" 120/208V 30 100A MLO ENGRAVED LAMACOID, 5/32" LETTERS, SECURE TO PANEL BOARD COVER WITH ADHESIVE TYPE FASTENER. LOAD CENTER CONSTRUCTION TO FIT IN STANDARD STUD WALL. COORDINATE WITH GENERAL CONTRACTOR. 2-LCM-E300-REV 0.0 ELECTRICAL LOAD SUMMARY PANEL "A" LOAD DESCRIPTION CONNECTED LOAD (KW) DEMAND FACTOR DEMAND FACTOR (KW) LIGHTING 1.47 1.25 1.84 SHOW WINDOW RECEPTACLES 0.00 1 0.00 SIGN 0.96 1.25 1.19 RECEPTACLES 4.26 100% <10K 4.26 EQUIPMENT 1.92 1 1.92 WATER HEATING 4.80 1.25 6.00 HVAC 0.00 1.25 OF LARGEST 0.00 TOTALS: 13.40 TOTALS: VOLTAGE DROP CALCULATIONS 15.21 VOLTAGE DROP TO BE LESS THAN 3%VD= MACY'S PANEL TO PANEL IN SPACE: 2 x L x R x I 1000 • DISTANCE TO SPACE: WIRE SIZE TO SPACE: AMPS: VD= VD %= 2.03 60 FT 4#6 (R=.4) 42.25 2.03 VOLTS VD x 100 208V X 100 = 0.98 208V 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL LANDLORD REQUIREMENTS PRIOR TO BIDDING & INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, & CHARGES IN HIS BID. 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE LANDLORD PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL. 3. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL. 4. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE- REQUIRED CLEARANCES. 5. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 6. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL EQUIPMENT. 1-LCM-E300-REV 0.0 DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 3-LCM-E300-REV 0.0 Panel Name: Voltage: Amps: MC B: A 120/208 100A MLO Options: 120/208 or 277/480 Buss amps can be standard, 100A minimum Main Circuit breaker amps Panel Type: Load center AIC Rating: 10K WATTS PER PHASE A B C DESCRIPTION OF LOAD AMBIENT LIGHTING AND CONTACTORS CASEWORK LIGHTING AND SIGNS SPARE RECEPT: EQ22 SPARE SPARE RECEPT: EQUIPMENT RECEPT: EQUIPMENT RECEPT: EQUIPMENT SALES FLOOR CASHDESK FRAME WARMER AT BACKWRAP SPARE OCPD 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT# 1 3 5 7 9 11 13 15 17 19 21 23 CKT# 2 4 6 8 10 12 14 16 18 20 22 24 OCPD 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 25/1 25/1 DESCRIPTION OF LOAD SALES FLOOR SUPPLEMENTAL TRACK CONVENIENCE OUTLETS DOCTOR'S OFFICE WORK AREA SPARE SPARE SPARE DATA CABINET SPARE DIGITAL SIGNAGE SPARE WATER HEATER WATER HEATER WATTS PER PHASE A C 2667 2462 360 Load Characteristics: Total Load, Phase A: Total Load, Phase B: Total Load, Phase C: Total Panel Load: Totals Voltage (360 for 120/208; 830 for 277/480) 360 3747 Amps per Phase A: 5222 Amps per Phase B: 4435 Amps per Phase C: 13404 Total Amps (assumes balanced): 10 15 12 37 Totals SEPI x-. TE PERMITAND APPROVAL RECEIVED CITY OF TUKWILA MAY 182017 DESIGN & CONSTRUCTION MANAGEMENT: o 40001uxottica Place, Mason, OH 45040 0 6 Creamery Brook, East Granby, CT 06026 RE 0 +1(513)765-6000 0 +1(516) 393-2484 Store A68932 SOUTHCENTER 500 SOUTHCENTER MALL TUKWILA, WA 98188 Construction for: LLI � O O O U 0 O c x O C N 2 � U y_ n3 O p_ O O LLJQCD 0 Macy's Store Number: Revisions: Mark Date By 4/)0117 ST CLIENT COMMENTS A A A A Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd. Suamico, WI 54173 (920)-445-5007 EXPIRES 12-09-17 Architect / Engineer Job No.: Nextore Store Design Revision No.: REV 1 Nextore project Number 74117 Brand Design Type: LCM MODULAR ISSUED FOR: 0 Client Review ElDOB Permit ❑DOB Permit- Re -Submit ❑ LL Approval El Bid 0 Construction Title RISER AND SCHEDULES Date Sheet 04/06/2017 Drawn By STAFF E300 Checked By MPR