HomeMy WebLinkAboutPermit D17-0153 - STOTTS RESIDENCE - PIN PILES FOR FOUNDATIONSTOTTS RESIDENCE 13716 45T" AVE S D17-0153 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 7347600330 Permit Number: D17-0153 13716 45TH AVE S Project Name: STOTTS RESIDENCE Issue Date: 6/19/2017 Permit Expires On: 12/16/2017 Owner: Name: KLEIN DEVON C Address: P 0 BOX 733 , KENT, WA, 98035 Contact Person: Name: TARA TODD Address: 1912 S 14+6 ST , SEATAC, WA, 98168 Contractor: Name: MATVEY CONSTRUCTION INC Address: 1912 S 146TH ST, SEATAC, WA, 98168 License No: MATVECI991CB Lender: Name: CONTRACTORS BONDING & INSURANCE CO Address: DEPT 3500 PO - BOX 844122 , KANSAS CITY, MO, 64184 Phone: (253) 680-9200 Phone: Expiration Date: 9/29/2017 DESCRIPTION OF WORK: INSTALL PIN PILES INDERNEATH AN EXISTING SINGLR FAMILY RESIDENCE TO STABILIZE THE FOUNDATION Project Valuation: $17,800.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $772.78 Occupancy per IBC: R-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature:' (' t�(�(% ' IA(/10 Date: lq I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority.to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perm't and agree to the conditions attached to this permit. Signature: Print Name: Date: G/1611 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 4036 SI -DRIVEN DEEP FOUND 4046 SI-EPDXY/EXP CONC 4034 SI -METAL PLATE CONN 4004 SI -WELDING CITY OF TUKWILA Community Development Department Public Works Department Per»tit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: D 92 to 11 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 13716 45th Ave S, Tukwila Wa 98168 Site Address: 13716 45th Ave S, Tukwila Wa 98168 King Co Assessor's Tax No.: 734760-0330 Suite Number: Floor: 'tenant Name: Doug White & Kevin Stotts PROPERTY OWNER Name: Tara Todd Name: Devon Klein City: Seatac State: Wa Zip: 98168 Address: 7530 43rd Ave, #B Email: permits@matveyfoundationrepair.com City: Seattle State: Wa Zip: 98118 CONTACT PERSON -- person receiving all project communication Name: Tara Todd Address: 1912 S 146th St City: Seatac State: Wa Zip: 98168 Phone: (253) 680-9200 Fax: Email: permits@matveyfoundationrepair.com GENERAL CONTRACTOR INFORMATION Company Name: Matvey Foundation Repair Address: 1912 S 146th St Company Name: City: Seatac State: Wa Zip: 98168 Phone: (253) 327-1650 Fax: Contr Reg No.: Matveci99l cb Exp Date: 09/27/2017 Tukwila Business License No.: BUS -0997724 HAApplications\I ontts-Applications Oa Linc120E E Applicaticats \Pcrmit Application Revised, $-4-i 1,406, Iteviscd; August 2011 l,t, New Tenant: ❑ Yes ..No ARCHITECT OF RECORD I Company Name: SFA Design Group Engineer Name: Jeff Fitch Company Name: City: Portland State: Or Zip: 97223 Phone: (503) 641-8311 Fax: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD I Company Name: SFA Design Group Engineer Name: Jeff Fitch Address: 9020 SW Washington Sq Dr Suite 505 City: Portland State: Or Zip: 97223 Phone: (503) 641-8311 Fax: Email: engineering@sfadg.com LENDER/BOND ISSUED (required for projects $5,000 or. greater per RCW 19.27.095) Name: Contractors Bonding & Insurance Co Address: Dept 3500 PO Box 844122 City: Kansas City State: MO Zip: 64184 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's hid price): $ 17,800 Existing Building Valuation: $ 32,000 Describe the scope of'work (please provide detailed information): Installing pin piles underneath an existing single family residence to stabilize the foundation. Will there be new rack storage? ❑ Yes E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Will there he a change in use? 1 0 Yes Compact: 0 handicap: 0 Qj No If"yes", explain: Ilia FIRE PROTECTION/HAZARDOUS M.ATER1ALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) • Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 84/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. I \ \piilicationsWornss.Applicatimu on Line\2011 Applications Permit Application Revised - 8.9•t I.does Rcviscd: August 2011 1,8 Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor 1,060 0 0 0 pin piles 2t'{l Floor 3�Floor Floors thru Basement Accessory Structure* Attached Garage 290 0 0 0 ti/a. Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Will there he a change in use? 1 0 Yes Compact: 0 handicap: 0 Qj No If"yes", explain: Ilia FIRE PROTECTION/HAZARDOUS M.ATER1ALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) • Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If "yes', attach list of materials and storage locations on a separate 84/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. I \ \piilicationsWornss.Applicatimu on Line\2011 Applications Permit Application Revised - 8.9•t I.does Rcviscd: August 2011 1,8 Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Installing pin piles underneath an existing single family residence to stabilize the foundation. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ®...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ®...Valley View ❑ .. Renton 0...Sewer Availability Provided 0 .. Renton 0 ., Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ® ...Civil Plans (Ma> isnum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (tnark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance E ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way VI ® ...Total Cut 3 cubic yards ® ...Total Fill 3 cubic yards ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑.,.Traffic impact Analysis ❑ ... Hold Harmless — (SAO) ...H old Harmless— (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone 0 .. Stone Drainage 0 ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor 0 ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation 0 ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 _ Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: ❑ ...Sewage Treatment Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip 11: 1ApplicasionsTorres-Applications o❑ Line1201.1 Applications\Pcreei Applietn ion Revised - 5-9-I r.docx Revised: August 2011 i>It Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ ANI) EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O'V 'ER OR AUTHORIZED AGENT: Signature: ( ir%,,n„ ;'(T 3A _r- Date: 0 .7L Print Name: Devon KleinDay Telephone: (253) 332-2645 Mailing Address: 7530 43rd Ave, #B Seattle Wa 98118 City Slate Zip li tAptillcations oflB-Appliottipn On Linc\2Ot 1 ApplicatuinsiPermit Ap,Iicaiinn Reeisrd - 8.9-11.doe, Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $772.78 D17-0153 Address: 13716 45TH AVE S Apn: 7347600330 $772.78 DEVELOPMENT $750.18 PERMIT FEE R000.322.100.00.00 0.00 $451.93 PLAN CHECK FEE R000.345.830.00.00 0.00 $293.75 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11646 R000.322.900.04.00 0.00 $22.60 $772,78 Date Paid: Tuesday, June 06, 2017 Paid By: MATVEY CONSTRUCTION INC Pay Method: CHECK 2011 Printed: Tuesday, June 06, 2017 2:47 PM 1 of 1 rPF-fi SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 7- c/s1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 vit Project: .s7-cr7 .3 i265 0 AJ Type of Inspection: 1jb9 '.U) vow IT" i41 Address: Is -7) 4cm ,4 % S Date Called: Special Instructions: Date Want d:.,'f '7 13/i i p.m. Request / Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: fit / 'S 7- 6v `-Oe€e d)Rtil€N bu-T7MAJ' Inspector: 5 Date: _ 7 /2_/7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SFA Design Group, u.c STRUCTURAL 1 CIVIL I LAND USE PLANNING 1 SURVEYING 9020 SW Washington Square Dr, Suite 505 - Portland, OR 97223 1813 Rutan Dr, Suite C - Livermore, CA 94551 P: (503) 641-8311 F: (503) 643-7905 www.sfadg.com STRUCTURAL CALCULATIONS Klein Residence Underpinning 13716 45th Avenue South, Tukwila, WA Ilananj Jjg "11 LIMITATIONS FILI! REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2011 City of Tukwila BUIL�I� ENGINEER WAS RETAINED IN A LIMITED CAPACITY FOR THIS PROJECT. DESIGN IS BASED UPON INFORMATION PROVIDED BY THE CLIENT WHO IS SOLELY RESPONSIBLE FOR ACCURACY OF SAME. NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY, OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. RECEIVED Project No. MFR17-036 CITY OF TUKWILA June 2, 2017 p 17-0153 JUN 0 6 2017 PERMIT CENTER SFA Design Group. LLE STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 1 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Push Pier Design Requirements BY DNL Structural Narrative The structural calculations and drawings enclosed are in reference to the design of the foundation underpinning of the 1 -story residence located in Tukwila, WA as referenced on the coversheet. The round steel tubes and retrofit brackets are used to stabilize and/or lift settling foundations. The bottom and back portion of the bracket is securely seated against the existing concrete footing. Using the weight of the existing structure, pier sections are continuously hydraulically driven through the foundation bracket and into the soil below until a load bearing stratum is encountered. Lateral earth confinement and a driven external sleeve with a starter pier provide additional stiffness to resist eccentric loading from the foundation. Once all piers are installed, they are simultaneously loaded with individual hydraulic jacks and closely monitored as pressure is applied to achieve desired stabilization and/or lift prior to locking off the pier cap. The piers are required to resist vertical loading from the roof framing, wall framing, floor framing, concrete slab on grade, and concrete turn -down footing. Underpinning the structure will remove lateral resistance provided by soil friction acting on the concrete foundation. Per the calculation, lateral resistance will be provided by soil friction acting on the unpiered portions of the concrete footing/concrete slab on grade and passive pressure acting on the buried footings perpendicular to the piered gridlines. There is no ICC -ES report currently approved for underpinning systems within Seismic Design Category D or higher, thus the entire underpinning system has been reviewed and analyzed and is therefore a fully engineered system complying with all current codes and stamped by a licensed design professional. Deep foundation guidelines, load combinations, special inspection and testing requirements per IBC 2015 have been included. Axial and bending capacities of the external sleeve, analysis of the retrofit foundation bracket, design reductions, and corrosion considerations have been incorporated in all required calculations per AISC 360-10. Concrete foundation span capacities have been analyzed per AC1318-14. Bracket fabrication welding has been performed by Behlen Mfg Co. conforming to AWS D1.1 performed by CWB qualified welders certified to CSA Standard W47.1 in Division 2. In addition, Behlen Mfg Co. has received US99/1690 certification meeting ISO 9001:2008 requirements by ANAB accredited SGS. General Building Department Building Code Conformance (Meets Or Exceeds Requirements) 2015 International Building Code (IBC) 2015 International Residential Code (IRC) (Dead Loads King County Roof Dead Load 15.0 psf Floor Dead Load 12.0 psf Wall Dead Load 10.0 psf Deck Dead Load 12.0 psf Concrete 150.0 pcf (Live Loads Roof Snow Load Deck Live Load Floor Live Load (Residential) 25.0 psf 60.0 psf 40.0 psf IN5FA Design Group. ux STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 2 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Design Loads BY DNL Worst Case Vertical Design Loads (Gridline 1) Tributary Width To Anchor = RoofDL = RoofSL 1 stFloorDL = 1 stFloon± = DeckDL = DeckLL = WaIIDL = StemwallDL = FootingDL = (15 psf) (14.50 ft) (25 psf) (14.50 ft) (12 psf) (6.25 ft) (40 psf) (6.25 ft) (12 psf) (3.00 ft) (60 psf) (3.00 ft) (10 psf) (9.00 ft) (150 pcf) (7.00 in) (150 pcf) (6.00 in) !Worst Case Vertical Design Loads (Gridline A/C) = 8.50 ft = 218 plf = 363 plf = 75 plf = 250 plf = 90 plf (12.00 in) = 88 plf (12.00 in) = 75 plf Dead Load 4.939 kips Floor Live Load 3.655 kips Roof Snow Load 3.081 kips Controlling ASD Load Combination: D+0.75L+0.75S Max Vertical Load to Worst Case Pier 9.991 kips Tributary Width To Anchor = RoofDL = RoofSL = 1 stFloorDL = 1 stFloorLL = DeckDL = DeckLL = WaIIDL = StemwallDL = FootingDL = (15 psf) (4.00 ft) (25 psf) (4.00 ft) (12 psf) (4.00 ft) (40 psf) (4.00 ft) (12 psf) (3.00 ft) (60 psf) (3.00 ft) (10 psf) (9.00 ft) (150 pcf) (7.00 in) (150 pcf) (6.00 in) = 7.00 ft = 60 plf = 100 plf = 48 plf = 160 plf = 90 plf (12.00 in) = 88 plf (12.00 in) = 75 plf Dead Load 2.524 kips Floor Live Load 1.120 kips Roof Snow Load 0.700 kips Controlling ASD Load Combination: D+0.75L+0.75Lr Max Vertical Load to Worst Case Pier 3.889 kips (E) CONC SLAB I ON GRADE (E) CRAWL I SPACE SFA Design Group, LLC S-R.,CT'J iAL CIVIL 1 LA''•1D l SE PLA NI\IC 3 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Pier Layout BY DNL Pier Layout N 2 1.-0" EQ E0 6'-0" t'-0" L6x6x5/16x3'-0" TYP (E) FOUNDATION/(N) PIER LAYOUT PLAN 1161 SFA Oesign Group, LLE STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 4 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Foundation Supportworks 2.875 in 0 Push Pier System BY DNL Design Input Pier System Designation = Vertical Load to Pier, PTL = Minimum Installation Depth, L = Unbraced Length, I = Eccentricity, e = Friction Factor of Safety, FS = Normal Surface Force, Fn = Design Load (Vertical), PDL = +MomentEccentricny = -MomentFriction = Design Moment, MomentPierDL = (Sleeve Property Input 2.875 in 0 9.991 kips 10.000 ft 0.500 ft 4.250 in 2 4.995 kips 9.991 kips 42.460 kip -in 0.000 kip -in 42.460 kip -in Sleeve Length = Design Sleeve OD = Design Wall Thickness = r= A= S= Z= I= E_ Fy = Note: Sleeve reduces bending stress on main pier from eccentricty 'Pier Property Input 48.000 in 3.434 in 0.183 in 1.151 in 1.871 int 1.444 in3 1.938 in3 2.480 in4 29000 ksi 50 ksi Design Tube OD = Design Wall Thickness = k= r= A. c= S= Z= 1= E = 29000 ksi Fy = 50 ksi 'Pier Output Per AISC 360-10 Doubly and Singly Symmetric Members Subject To Flexure and Axial Force Note: Design thickness of pier and sleeve based on 93% of nominal thickness per AISC and the ICC -ES AC358 based on a corrosion loss rate of 50 years for zinc -coated steel 2.823 in 0.136 in 2.10 0.951 in 1.146 int 1.411 in 0.734 in3 0.981 in3 1.037 in4 PIER CAP WITH THREADED RODS PIER EXTERNAL SLEEVE EXCAVATION III-�:I I -i78 71=11 if q_/PIER/ REACTION (E) STEMWALL AND FOOTING = Ir .11,1 REACTION AT LOAD BEARING STRATUM Note: Section above is a general representation of piering system, refer to plan for layout and project specific details. Note: Flexural design capacity based on combined plastic section modulous of pier and sleeve kl/r = 13.25 OK, <200 Fe = 1630.291 ksi 4.71 *(E/Fy).S = 113.43 49.362 ksi 56.6 kips 1.67 33.9 kips 9.991 kips D/tP1er = 20.8 Mn = 146.0 kip -in 1.67 87.4 kip -in 42.5 kip -in 0.73 Fcr = Pn = Safety Factor for Compression, Oc = Allowable Axial Compressive Strength, Pn/c), = Actual Axial Compressive Demand, Pr = 'Results Safety Factor for Flexure, Ob = Allowable Flexural Strength, Mn/lb = Actual Flexural Demand, Mr = Combined Axial & Flexure Check = OK, <.45E/Fy OK §E2 §(E3-4) §E3 §(E3-2 & E3-3) §(E3-1) §E1 §F8 §(F8-1) §F1 §(H1 -la & 1b) Max Load To Pier = Design Load = 9991 Ib 2.875" Diameter Pipe Pier with 0.165" Thick Wall 3.5" Diameterx48" Long Pipe Sleeve With 0.216" Thick Wall Minimum 10'-0" Installation Depth And Minimum 2100 psi Installation Pressure Minimum 1/4" Foundation Lift During Installation 5FA Design Group. LLC STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 5 of 12 PROJECT NO. MFR17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Foundation Supportworks FS288BL Bracket BY DNL Capacity of 3/4"0 GRB7 (125ksi) Threaded Rod 11 D = 0.750 in Ft = 125 ksi At = 0.344 in2 Capacity = 42.950 kips I Block Shear at 3/e" Platet0 and ® to ® Tss = 0.3(58)(3/8)(11)+0.5(58)(%)(2) = 93.525 kips Capacity of Weld ® E70 Electrodes = 70 ksi Size of Fillet = 0.188 in Length of Weld = 11.000 in Capacity of Per Inch of Fillet = 2.784 kli Capacity of Fillet = 30.627 kips Capacity of 3/e" Plate OO At=3.188in2 Ft = 21.600 ksi T = 68.850 kips 1= 0.031 in4 A = 0.375 in2 r = 0.289 in k = 1.00 I = 8.500 in kl/r = 30.0 Fa = 20.350 ksi S = 4.516 in3 Fb = 27.000 ksi RMAx = 15.429 kips Fv = 14.400 ksi VALLow = 43.200 kips I Results -4 Limiting System Factor Capacity of System (2 Sides) = 15.43(2)=30.86kips (Bracket Only) SFA Design Group, LLE STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 6 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT (E) Concrete Footing/Foundation Wall BY DNL Footing/Foundation Wall Section Properties Foundation Width, b = Foundation Depth, d = Cross Sectional Area, A = Section Modulus, Sx = Gross Moment of Inertia, I9 = Assumed Conc, f'c = 1Footing/Foundation Wall Loading 7 in 16 in 112 in2 299 in3 2389 in4 2500 psi Note: Reference design loads page of calculation package for loading conditions. !!N!!NI! Vii,: MEN •It 11. AS OCCURS (NOT CONSIDERED FOR MOMENT CAPACITY) -10 Footing/Foundation Wall Cross Section Dead Load, D = 0.581 klf Note: Load factors taken from AC1318-14 §5.3.1 Floor Live Load, L = 0.430 klf Roof Snow Load = 0.363 klf Governing Load Combination = 1.2D + 1.6S + L Wu= 1.707 klf Desired Pier Spacing, SD = 8.50 ft Maximimum Pier Spacing, SMAx = 7.97 ft Controls Pier Spacing, S = 4.83 ft Ultimate Shear (WS/2), Vu = 4123 lbs Ultimate Moment (WS^2/8), Mu = 4.98 k -ft IFooting/Foundation Wall Moment & Shear Capacity Per ACI318-11 Conc Modulus of Rupture, fr = 375 psi Cracking Moment, Mcr = S*fr = 9.3 k -ft Flexure Reduction Factor, 4) = 0.65 Design Moment, 4)Mcr = 6.1 k -ft > 4.98 k -ft Span Ok Shear Strength, Vc = 11200 lbs Shear Reduction Factor, 4) = 0.75 Design Shear, 0.50Vc = 4200 lbs > 4123 lbs Span Ok §19.2.3.1 §21.2.2 §22.5.5.1 §21.2.1 Note: Footing and foundation wall capacities are based on a worst case scenario of having no steel reinforcement. III SFA Design Group, LLE STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 7 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT (E) Concrete Footing/Foundation Wall (Gridline A/C) BY DNL Footing/Foundation Wall Section Properties Foundation Width, b = Foundation Depth, d = Cross Sectional Area, A = Section Modulus, Sx = Gross Moment of Inertia, Ig = Assumed Conc, f'c = Footing/Foundation Wall Loading 7 in 16 in 112 int 299 in3 2389 in' 2500 psi Note: Reference design loads page of calculation package for loading conditions. AS OCCURS (NOT CONSIDERED FOR MOMENT CAPACITY) Footing/Foundation Wall Cross Section Dead Load, D = 0.361 klf Note: Load factors taken from AC1318-14 §5.3.1 Floor Live Load, L = 0.160 klf Roof Snow Load = 0.100 klf Governing Load Combination = 1.2D + 1.6S + L Wu= 0.753 klf Desired Pier Spacing, SD = 8.50 ft Maximimum Pier Spacing, SMAx = 7.97 ft Controls Pier Spacing, S = 7.00 ft Ultimate Shear (WS/2), Vu = 2635 lbs Ultimate Moment (WSA2/8), Mu = 4.61 k -ft Footing/Foundation Wall Moment & Shear Capacity Per AC1318-11 Conc Modulus of Rupture, fr = 375 psi Cracking Moment, Mcr = S*fr = 9.3 k -ft Flexure Reduction Factor, 4) = 0.65 Design Moment, 4)Mcr = 6.1 k -ft Shear Strength, Vc = 11200 lbs Shear Reduction Factor, 4) = 0.75 Design Shear, 0.54)Vc = 4200 lbs > 4.61 k -ft Span Ok > 2635 lbs Span Ok §19.2.3.1 §21.2.2 §22.5.5.1 §21.2.1 Note: Footing and foundation wall capacities are based on a worst case scenario of having no steel reinforcement. SFA Design Group. u.x STRUCTURAL I CIVIL I LAND USE PLANNING 8 of 12 PROJECT NO. MFR17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Existing Lateral Resitance Along Gridline 1 BY DNL Footing/Foundation Wall Section Properties Foundation Width, b = 7 in Foundation Depth, d = 18 in Int Buried Footing Depth, d, = 12 in Cross Sectional Area, A = 126 in, Section Modulus, So = 147 in3 Gross Moment of Inertia, la = 3402 in` Assumed Conc, f'c = 2500 psi (Footing/Foundation Wall Moment & Shear Capacity Per ACI318-14 Conc Modulus of Rupture, fr = 375 psi Cracking Moment, Mcr = S`fr = 4.6 k -ft Flexure Reduction Factor, 4) = 0.65 Design Moment, 4)Mur = 3.0 k -ft Shear Strength, Vo = 12600 lbs Shear Reduction Factor, 4) = 0.75 Design Shear, 0.54Vc = 4725 lbs AS OCCURS (NOT CONSIDERED FOR MOMENT OR SHEAR CAPACITY §19.2.3.1 §21.2.2 §22.5.5.1 §21.2.1 b Note: Footing and foundation wall capacities are based on a worst case scenario of having no steel reinforcement. (Passive Pressure From Perpendicular Return Walls (Along Gridline 1) Effective Friction Angle = 32° Passive Coefficient, KP = tan^2'(45+0'/2) KP =3.25 Soil Unit Weight, y = 110 pcf Passive Pressure, Pp = KP y = 358 pcf Ext Buried Soil Depth, d° = d-12" = 0.5 ft Ext Buried Soil Depth, d, = di -12" = 0.0 ft A = Pp`(dc) = 90 psi B = Pp'(d;) = 0 psf w, = A`d°/2 = 45 Of w�=8'd/2=0plf IFooting/Foundation Wall Loading Note: Reference design loads page of calculation package for load tvext combinations. 1 ( l t ( ( ) � .�.�.� 1' 1 11111111111 wint Iv Exterior Length Due to Moment, L° = 1/(8'43.`fr`Ige. /(y,'w°,,,)/2 = 10.09 ft Interior Length Due to Moment, L,,, =1./(8"4)"l,`lont/(y weA)/2 = 0.00 ft Exterior Length Due to Shear, Le = 0.54)V /we = 52.79 ft Interior Length Due to Shear, La, = 0.54V„/w. = 0.00 ft Rpm= w� Le = 452 lbs RAnt= w, d l.ti = 0 lbs Lateral Capacity, Rp= Rpw+Rp^, = 452 lbs ISIab on Grade Frictional Resistance Note: Section about is a general representation of a concrete footing. Refer to plans for specific details Moment Controls Slab Along This Line = Yes Coeficient of Soil Friction = 0.30 Length of Resisting Line = 13 ft Tributary Width of Slab = 5 ft Slab Thickness = 4 in Concrete Weight = 150.0 pcf Soil Friction VRESIST= 975 lbs Footing Frictional Resistance Along Gridline 1 Unpiered Portion of Gridline 1 = Yes Coeficient of Soil Friction = 0.30 Length of Resisting Line = 14 ft Dead Load Above = 581 plf Soil Friction VRESIST = 2440 lbs Total available resistance along Gridline 1 = 4521bs + 9751bs + 24401bs = 38671bs IIM5FA Design Group, Lcc STRUCTURAL 1 CIVIL I LAND USE PLANNING 9 of 12 PROJECT NO. MFR17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Seismic Design Criteria BY DNL ASCE 7-10 Chapters 11 & 12 Soil Site Class = D Response Spectral Acc. (0.2 sec) Ss = 149.00%g Response Spectral Acc.( 1.0 sec) S, = 55.80%g Site Coefficient Fa Site Coefficient F, Max Considered Earthquake Acc. SMs= Max Considered Earthquake Acc. SM1 = @ 5% Damped Design SDs = SD1 = Risk Category = Seismic Design Category for 0.1 sec Seismic Design Category for 1.0 sec S1 < 0.75g Since Ta < .8Ts (see below), SDC = §12.8 Equivalent Lateral Force Procedure Seismic Force Resisting System (E -W) Seismic Force Resisting System (N -S) CI = Fa. Ss F,,.S, 2/3(SMs) 2/3(SMI) 11, Standard Flexible Diaphragm D D = 1.490g = 0.558g = 1.000 = 1.500 = 1.490g = 0.837g = 0.993g = 0.558g N/A D Tab. 20.3-1, (Default = D) Figs. 22-1, 22-3, 22-5, 22-6 Figs. 22-2, 22-4, 22-5, 22-6 Tab. 11.4-1 Tab. 11.4-2 (11.4-1) (11.4-2) (11.4-3) (11.4-4) Tab. 1.5-1 §12.3.1 Tab. 11.6-1 Tab. 11.6-2 §11.6 Exception of §11.6 does not apply A. BEARING WALL SYSTEMS Tab. 12.2-1 15. Light -framed (wood) walls sheathed with wood structural panels rated for shear resistance or steel sheets A. BEARING WALL SYSTEMS Tab. 12.2-1 15. Light -framed (wood) walls sheathed with wood structural panels rated for shear resistance or steel sheets 0.02 x = 0.75 Tab. 12.8-2 Structural height h„= 14.0 ft C = 1.400 Approx Fundamental period, Ta = CI(hn)" TL = 6 sec Calculated T shall not exceed <_ CeTa Use T = 0.14 sec Structural Height Limit = 65.0 ft for SDI of 0.558g = 0.145 = 0.203 0.8Ts = 0.8(So,/SDs) = 0.449 Is structure Regular & < 5 stories ? Yes Response Modification Coefficient R = Over Strength Factor Ste = Importance factor le = Seismic Base Shear V = Cs = or need not to exceed, Cs = or Cs= Min Cs = Use Cs = Design base shear V = E -W 6.5 2.5 1.00 Cs W Sns = 0.153 R/Ie Sm = 0.593 (R/ILIT Sn,T, N/A T2(R/le) 0.5S,1e/R N/A 0.153 0.153 W Tab. 12.2-1 Tab. 12.8-1 (12.8-7) Figs. 22-12 through 22-16 Exception of §11.6 does not apply §12.8.1.3 Max Ss < 0.15g N -S 6.5 2.5 1.00 Cs W Snc = 0.153 R/Ie $ni = 0.593 (R/1.1T N/A Sn,T, T2(R/Ie) 0.5S, le/R N/A 0.153 0.153 W Tab. 12.2-1 (foot note g) Tab. 11.5-1 (12.8-2) For T < TL (12.8-3) For T > TL (12.8-4) For S, >_ 0.6g (12.8-6) RBI SFA Design Group. LLE STRUCTURAL 1 CML I LAND USE PLANNING 10 of 12 PROJECT NO. MFR17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Wind Design Criteria BY DNL Wind Analysis for Low-rise Building, Based on ASCE 7-10 INPUT DATA Exposure category (8, C or 8, ASCE 7-10 26.7.3) B Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC) V = 110 mph Topographic factor (ASCE 7-10 26.8 & Table 26.8-1) Kzt = 1.00 Flat Building height to eave he = 9 ft Building height to ridge hr = 14 ft Building length L = 37 ft Building width B = 45 ft (Velocity pressure qh = 0.00256 Kh Kx1 Kd V2 = 18.43 psf where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299) = 0.700 Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250) = 0.85 h = mean roof height = 11.50 ft < 60 ft, Satisfactory (ASCE 7-10 26.2.1) !Design pressures for MWFRS p = qh [(G Cpf )-(G C1 )] where: p = pressure in appropriate zone. (Eq. 28.4-1, page 298). Pmin = 16 psf for wall area (ASCE 7-10 28.4.4) Pmin = 8 psf for roof area (ASCE 7-10 28.4.4) G C, f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.4-1, page 300 & 301) G Cr, = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, Enclosed Building, page 258) 0.18 or -0.18 a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1 B, 0.1 L, 0.4h), MIN(0.04B, 0.04L), 3] = inlet rressures (par , Loao t..ase r+ 3.70 ft Surface Roof angle 9 = 12.53 GCPf Net Pressure with (+GCei) (-GCPI) 1 0.47 11.89 5.26 2 -0.69 -9.40 -16.03 3 -0.43 -4.52 -11.15 4 -0.36 -3.32 -9.96 1E 0.71 16.32 9.68 2E -1.07 -16.40 -23.04 3E -0.66 -8.85 -15.48 4E -0.54 -6.55 -13.19 Surface Roof angle 0 = 12.53 G CPf Net Pressure with O, CJ1 A W N 1 01 CI'A W N -' mmmm m m -0.45 -4.98 -11.61 -0.69 -9.40 -16.03 -0.37 -3.50 -10.14 -0.45 -4.98 -11.61 0.40 10.69 4.05 -0.29 -2.03 -8.66 -0.48 -5.53 -12.16 -1.07 -16.40 -23.04 -0.53 -6.45 -13.09 -0.48 -5.53 -12.16 0.61 14.56 7.93 -0.43 -4.61 -11.24 Load Case A (Transverse) Load Case B (Longitudinal) Basic Load Casa$ 5FA Design Group. LLC STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 11 of 12 PROJECT NO. MFR 17-036 SHEET NO. PROJECT Klein Residence Underpinning DATE 6/2/2017 SUBJECT Lateral Design Loads Along Gridline 1 BY DNL Wind Base Shear Along Gridline 1 Loading Direction: Transverse End Zone (1 E+4E) = Tributary Width = Tributary Height = End Zone (2E+3E) Tributary Width = Tributary Height = 'Seismic Base RoofDL = 1st FloorDL = WaIIDL = StemwallDL = FootingnL = PerpWallsDL = 16.3 psf 7.40 ft 9.00 ft 8.0 psf 7.40 ft 5.00 ft Design base shear VWIND = ASD(60%) base shear VWIND = Zone (1+4) = Tributary Width = Tributary Height = Zone (2+3) Tributary Width = Tributary Height = a= 2652 lbs 1591 lbs Seismic Controls Load Case A (Transverse) Load Case B (Longitudinal) Basic Load Cases Shear Along Gridline 1 16.0 psf 6.90 ft 9.00 ft 8.0 psf 6.90 ft 5.00 ft 3.70 ft (15 psf) (14.50 ft) (12 psf) (12.50 ft) (10 psf) (150 pcf) (150 pcf) (10 psf) Design base shear VSEISMIC = ASD(70%) base shear VsEls = (4.50 ft) (6.00 in) (6.00 in) (18.00 ft) (12.00 in) (12.00 in) (25.00 ft) = 218 plf = 150 plf = 45 plf = 75 plf = 75 plf = 4500 Ib 5395 lbs 3776 lbs -4Seismic Controls Base shear = Trib Length = Worst Case Lateral Load Along Gridline 1 = 3776 lbs Total Available Lateral Resistance Along Gridline 1 = 3867 lbs No Additional Lateral Resistance Required 0.153 W 37 ft 12 of 12 Steel Beam Lic. # : KW -06005923 Description : Steel Angle CODE REFERENCES File = Z:1#PROJE-112017PR-11#2017P-11#2017W-11MFR17--1.TUK(Calcslklein.ec6 ENERCALC, INC. 1983-2015, Build:6.15.7.30, Ver:6.15.6.30 Licensee : SFA ENGINEERING LLC Calculations per AISC 360-10, IBC 2012, ASCE 7-10 Load Combination Set : IBC2012 Material Properties Analysis Method : Allowable Strength Design Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Bending Axis : Major Axis Bending Load Combination 1BC2012 Fy : Steel Yield : E: Modulus : 36.0 ksi 29,000.0 ksi D(0.581) L(0.43) S(0.363) i + + Span = 2.50 ft L6x6,,7/16 0(1.406) L(1 04) S(0.878) Applied Loads Beam self weight NOT internally calculated and added Uniform Load : D = 0.5810, L = 0.430, S = 0.3630 k/ft, Tributary Width = 1.0 ft Point Load: D = 1.406, L=1.040, S= 0.8780 k@2.50ft DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. Design Maximum Bending Stress Ratio = 0.989: 1 Section used for this span L6x6x7/16 Ma : Applied 10.785 k -ft Mn / Omega : Allowable 10.902 k -ft Load Combination +D+0.750L+0.750S+H Location of maximum on span 0.000ft Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Maximum Shear Stress Ratio = Section used for this span Va : Applied Vn/Omega : Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.025 in Ratio = 0.000 in Ratio = 0.034 in Ratio = 0.000 in Ratio = 2,366 0 <600 1751 0 <600 0.170: 1 L6x6x7/16 5.784 k 33.952 k +D+0.750L+0.750S+H 0.000 ft Span # 1 FILE 45TH AVE S DRIVEWAY _.._.._.._1._ SIDEWALK N 30' Open Porch 60 RESIDENCE 13716 45TH AVE S, TUKWILA, WA, 98168 5' PROJECT DATA PROJECT DESCRIPTION: UNDERPINNING OF EXISTING BUILDING FOR FOUNDATION STABILIZATION ASSESOR PARCEL No: 734760-0330 PROPERTY ADDRESS: 13716 45TH AVE S, TUKWILA, WA, 98168 OWNER(S): KLEIN DEVON C LEGAL DESCRIPTION: RIVERTON MACADAM ROAD TRS PLat Block: 4 Plat Lot: 4 ZONING: LDR; (Single Family(Res Use/Zone)) LOT AREA: 0.20 ACRES (8,500 SqFt) 1 PL. 170 LEGEND _-(5) Project Work Area(s): T Underpinning of existing building for foundation stabilization. Temporary Excavation and tJ Adjacent to Footing (2x2x3) Adjacent properties will not be affected. Temporary excavation is adjacent to the footing, to the depth of the footing 165 0 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 062017 PERMIT CENTER SITE PLAN SCALE: 1" = 20' 0" bstgo [‘.5 ?0 5 0 %////2/// 20 0 e 0 t0 0 v 0 0 -0 vo 0 yP '> E ij "� _. E a0 V in '7 v r a;U c 75 15) oo p U coX c t0, o C0C . m— v PARCEL No: 734760-0330 SITE PLAN SCALE: 1" = 20' 0" REVISIONS: PROJECT No: PD 2017.06.28.00 DATE: 06-05-2017 DRAWN BY: NU SHEET 1 of 1 pi PLANNING APPROVED i lenges can be madeto these ns without approval from the Planning Division of DCD Approved By: KT) 1 Date: SEPARATE PERMIT REQUIRED FOR: C'Mechanicai eTieciricat laslPas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be Made to the scope of work without prior approval of Tuk Ila Building Division. NOTE: Revisio ,s will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. 3 Plan review cpproval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Rid ;..p �� d conditions is acknowledged: By: Date: Colic( 1 11— City of Tukwila BUILDING DIVISION b XI-- 0 I 5 3 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 142017 Vug City of Tukwila BUILDING DIVISION 1. GENERAL STRUCTURAL NOTES: REFER TO SUBSEQUENT PLAN AND DETAIL NOTES FOR VARIATIONS AND REQUIREMENTS SPECIFIC TO REFERENCED PROJECT. NOTES ON DRAWINGS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. 2. DESIGN CRITERIA: BUILDING CODE CONFORMANCE (MEETS OR EXCEEDS REQUIREMENTS): 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) DEAD LOADS: ROOF DEAD LOAD FLOOR DEAD LOAD WALL DEAD LOAD CONCRETE LIVE LOADS: ROOF SNOW LOAD FLOOR LIVE LOAD (RESIDENTIAL) 15 PSF 12 PSF 10 PSF 150 PCF 25 PSF 40 PSF 3 MATERIALS: BRACKET PLATES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) PIER TUBES - ASTM A500 GRADE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 55 KSI) EXTERNAL SLEEVE - ASTM A500 GRADE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 62 KSI) PIER CAP - ASTM A529 GRADE 50 (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) ALL -THREAD ROD - ASTM A193 GRADE B7 (MIN YIELD STRESS, Fy = --- / MIN TENSILE STRESS, Fu = 125 KSI) STEEL ANGLE SHAPES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu 58 KSI) 4 WELDING NOTES: CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. 5. CORROSION PROTECTION: SACRAFICIAL DESIGN THICKNESS - CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50 -YEAR SCHEDULED SACRAFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC -ES AC358. 6 INSTALLATION: SYSTEM TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION PRESSURE IS TO BE DETERMINED BY THE FOLLOWING EQUATION: PUSH PIER INSTALLATION PRESSURE (PSI): [DESIGN LOAD] X 2 / 9.62 IN2. MINIMUM INSTALLATION DEPTH IS 10'-0"± UNO. CONTACT ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER. 7. EXISTING UTILITY LINES: CONTRACTOR TO REPAIR UTILITY LINES THAT MAY BE DAMAGED DURING INSTALLATION. 8. PUSH PIER SPLICING: PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE JOINTS DO NOT SEPARATE. 9 INSPECTION & TESTING: CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION PER 2015 IBC SECTION 1810.4.12. THE SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: -PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER) - FOUNDATION SUPPORTWORKS INSTALLER CERTIFICATION -PILE AND BRACKET CONFIGURATION - PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, PIER WALL THICKNESS) - PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED LOAD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD) ON 20 PERCENT OF PIERS AND WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT LOAD (AL) SHALL BE APPLIED TO THE PILE PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO ZERO OR A REFERENCE POSITION. THE AL SHALL BE NO MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. TEST LOADING SCHEDULE AL (.10 DL MAX) 0.25 DL 0.50 DL 0.75 DL 1.00 DL 1.25 DL 1.50 DL 1.25 DL 1.00 DL 0.75 DL 0.50 DL 0.25 DL HOLD TIME 0 MIN. UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE HOLD FOR CREEP TEST UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE MAX DEFLECTION REVIEWED FOR CODE COMPLIANCE APPROVED (SEE BELOW) 0. NCHN 1 4 2017 City of Tukwila BUILDING DIVISION LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES WITHIN A 10 MINUTE PERIOD. IF MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD THE LOAD TEST SHALL BE HELD FOR AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND RE -TESTED, OR THE PIER IS TO BE ABANDONED AND REPLACED WITH A NEW PIER. IF THE LOAD TEST IS TO BE HELD THE PIER MOVEMENTS SHALL BE MEASURED AT 15, 20, 30, 40, 50, AND 60 MINUTES. THE CREEP VERSUS THE LOGARITHM OF TIME SHALL BE PLOTTED. IF THE CREEP RATE IS LESS THAN 0.080 INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. RECEIVED CITY OF TUK PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / 9.62 IN2. DO NOT PLACE PIERS THIS ZONE W/O DIRECTION FROM ENGINEER NO PIER PLACEMENT ZONE SCALE: NTS bfl 0153 5FA Design Group, LLC STRUCTURAL l CIVIL l LAND USE PLANNING 9020 SW Washington Square Dr., Suite 505 Portland, Oregon 97223 191nut. Or., unit Livermore, Cai'IFomla 96551 p: 503.661.9311 vmv. tatlpxom 0 W CC z 0 0 z 0 >- LU Z_ Z Z E coW D Z corn Q W Zig Wco d- (7),„ D CC T H Z W J JUN 0 6 2011 DO NOT PLACE P I MIT CEN THIS ZONE W/O DIRECTION FROM ENGINEER CONTRACTOR TO NOTIFY EOR IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATIOI' BRACKETS 'REVISIONS TER PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 SHEET NO: S1.1 ria 41,/ \ /BPI / Prff:d \ / s 72.i/—/---• NO PIER PLACEMENT ZONE SCALE: NTS bfl 0153 5FA Design Group, LLC STRUCTURAL l CIVIL l LAND USE PLANNING 9020 SW Washington Square Dr., Suite 505 Portland, Oregon 97223 191nut. Or., unit Livermore, Cai'IFomla 96551 p: 503.661.9311 vmv. tatlpxom 0 W CC z 0 0 z 0 >- LU Z_ Z Z E coW D Z corn Q W Zig Wco d- (7),„ D CC T H Z W J JUN 0 6 2011 DO NOT PLACE P I MIT CEN THIS ZONE W/O DIRECTION FROM ENGINEER CONTRACTOR TO NOTIFY EOR IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATIOI' BRACKETS 'REVISIONS TER PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 SHEET NO: S1.1 L6x6x 7/16x3' -0" EQ EQ 1,-0" (E) FOUNDATION/(N) PIER LAYOUT PLAN SCALE: 11g"=1'-0" (E) FOUNDATION/(N) PIER LAYOUT PLAN NOTES: 1. REFERENCE S1.1 FOR GENERAL REQUIREMENTS 2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD OF DISCREPANCIES BETWEEN FIELD CONDITIONS Sc THOSE SHOWN IN THESE DOCUMENTS PRIOR TO CONSTRUCTION/INSTALLATION OF PIERS TYP 3. INDICATES (E) CONC STEMWALL ON (E) CONC FOOTING (CONTRACTOR TO VERIFY (E) 7"Wx1'-0"DP CONC STEMWALL ON A (E) 1'-0"Wx6"DP CONC FOOTING MIN TYP (NOTIFY ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER)) INDICATES (E) CONC TURNDOWN FOOTING (CONTRACTOR TO VERIFY 1'-0"Wx1'-6"DP (E) CONC TURNDOWN FOOTING MIN TYP (NOTIFY ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER)) 4, SECTION CUT - DETAIL NUMBER/SHEET NUMBER 5. ® INDICATES LOCATION OF FSI PP288 PUSH PIER W/ FSI FS288BL FOUNDATION BRACKET PER DETAILS ON S4.1 PUSH PIER INSTALLATION NOTES: • MAX LOAD TO ANCHOR = 9991 LBS • 2.875"0 PIPE PILE W/ 0.165" THICK WALL • 3.5"0x48" LONG PIPE SLEEVE W/ 0.216" WALL • MINIMUM 10'-0" INSTALLATION DEPTH • MINIMUM 2100 PSI INSTALLATION PRESSURE • MINIMUM 1/4" FOUNDATION LIFT DURING INSTALLATION 6. PIER SPACING SHALL BE AS INDICATED ON PLAN (7'-O" OC MAX UNO) 7. MAX UNSUPPORTED FOUNDATION SPAN SHALL BE 4'-10" 8. CONTRACTOR TO NOTIFY ENGINEER OF RECORD IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS 9. ALL CONSTRUCTION MATERIALS ON PLANS, ELEVATIONS & DETAILS ARE (N) UNO REVIEWED FOR GODE COMPLIANCE APPROVED JUN 14 2017 r City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0 6 2017 PERMIT CENTER 5FA oesign Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Or.. Suite 505 Portland, Oregon 97223 1813 Ratan Dr., Unit C Livermore, California 94551 p: 503.641.8311 www.sfatl9.com 0 W O3� p Z rn Q � Q o U= z � LL iVi M I- 2 KLE (E) FOUNDATION/ (N) PIER LAYOUT PLAN REVISIONS • • PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 SHEET NO: S2.1 10 2/S4.1 1 Q/HOLES /HOLE Mt/HOLE q/HOLE 1 4/S4.1 NOTE: CAP R NOT SHOWN FOR CLARITY FS288BL BRACKET - TOP SCALE: 1 1/2"=1'— fl 1/S41 1 /CAP R/PIPE/HOLES_ 1 6/S4.1 FS288BL BRACKET - RIGHT SCALE: 1 1/2"=1'-0" N M 1/S41 1 y„ 4 7,, -0/2" 4.1 111444 -1'' 1'-2" 6/S4.1 FS288BL BRACKET - LEFT SCALE: 1 1/2"=1'-0" SECTION A -A N 1/S41 1/S41 /R's/PIPE/HOLES q./HOLES ./HOLES 1" CAP R1 x9x0'-5" 6/S4.1 FS288BL BRACKET - FRONT RECEIVED CITY OF TUKWILA JUN 06 2017 PERMIT CENTER FS288BL BRACKET - BACK REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2017 City of Tu la BUILDING DIVISION SCALE: 1 1/2"=1'-0" 4/S4.1 TYP 2/S4.1 q/HOLE ../It/HOLE /HOLE 1 FS288BL BRACKET - BOTTOM SCALE: 1 1/2"=1'-0" sC SFA Design Group. LLC STRUCTURAL I CIVIL I LAND USE MANNING 9070 SW Washington Square Or., Suite 505 Fontana Slogan 97553 19139utan Dr., UngC Livermore, California94551 p: 503.641.9311 wwws1 5goom MATVEY FOUNDATION REPAIR z z z,; atCC W ozCO Q W = Uocc- W (7, z w J BRACKET DETAILS 'REVISIONS • PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 • SHEET NO: S4.1 (E) EXT GRADE 'I 1 7E7 11 11-_ HI NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (E) WALL FRAMING (E) FLOOR SHEATHING (E) FLOOR FRAMING (PARALLEL AS OCCURS) (E) CONC STEMWALL (E) INTERIOR GRADE 1111 I ITE -1 1 I' �' (E) CONC FOOTING Fl 1' i I I (CHIP FLUSH W/ III- STEMWALL AS REQ'D) I I _ ( STEEL ANGLE PER PLAN (AS OCCURS) FOUNDATION BRACKET PER PLAN FSI PUSH PIER & EXTERNAL SLEEVE PER PLAN (N) PUSH PIER TO (E) FDN DETAIL SCALE: 1"=1'-0" (E) SLAB ON GRADE (E) WALL FRAMING (E) FLOOR SHEATHING (E) FLOOR FRAMING (PARALLEL AS OCCURS) (E) CONC STEMWALL (E) INTERIOR GRADE I'' (E) CONC FOOTING -111- 11—III (CHIP FLUSH W/ —IIi- STEMWALL AS REQ'D) ill_ ' II- STEEL ANGLE PER PLAN (AS OCCURS) FOUNDATION BRACKET PER PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2017 City of Tukwila BUILDING DIVISION NOTE: REF PLAN FOR LAYOUT Sc INSTALLATION REQ'S FSI PUSH PIER & EXTERNAL SLEEVE PER PLAN (N) PUSH PIER TO (E) FDN DETAIL RECEIVED CITY OF TUKWILA JUN 062017 PERMIT CENTER SCALE: 1"1'-0' c2) sfa SFA Design Group. uc STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Or., Suite 505 Portland Oregon 97223 1813 Rohn Dr., Unit C Livermore, California 94551 p: 503.841.8311 wwwsfadg.nom MATVEY FOUNDATION REPAIR KLEIN RESIDENCE UNDERPINNING c W co D Z 09 rn a< M PIER DETAILS • REVISIONS • PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 SHEET NO: S4.2 (E) EXT GRADE (E) WALL FRAMING (E) SLAB ON GRADE 'I -- II1-- NOTE: - NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S III=11 I I (E) CONC FOOTING - STEEL ANGLE PER PLAN (AS OCCURS) FOUNDATION BRACKET PER PLAN FSI PUSH PIER & EXTERNAL SLEEVE PER PLAN (N) PUSH PIER TO (E) FDN DETAIL SCALE: 1"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 062017 PERMIT CENTER 5FA Design Group. LLC STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington 50uare Or., Suite 505 Portland, Oregon 97223 1813 Rutan Or., Unit C Livermore, California 94551 p: 503.641.8311 wwwsfadg.4om MATVEY FOUNDATION REPAIR 0 Z_ Z Z E7 W co W z co p CD Z rn Da< LUU Z W d- — a co CC y Z PIER DETAILS REVISIONS • • PROJECT NO: MFR17-036 DESIGNED BY: DL DRAWN BY: TKB DATE: 06-02-2017 SHEET NO: S4.3 --PERMIT COORD COPY PLAN REVIEW/ROUTING SLIF PERMIT NUMBER: D17-0153 DATE: 06/06/17 PROJECT NAME: STOTTS RESIDENCE SITE ADDRESS: 13716 45 AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /�- q%47 Building Division b M N/A- -7`( Public Works i4bt>r Al 641 7 Fire Prevention Planning Division Structural ❑ Permit Coordinator C21 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/08/17 Structural Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/06/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 MATVEY CONSTRUCTION INC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 3 _r�n;•f'P3 A -Z Index Help My L&I Workplace Rights Trades & Licensing MATVEY CONSTRUCTION INC Owner or tradesperson Principals COTE, MAT, PRESIDENT COTE, OLGA, VICE PRESIDENT (End: 04/17/2017) KOVTUN, VLADIMIR, SECRETARY (End: 04/17/2017) POPVYCH, IVAN, TREASURER (End: 04/17/2017) WICHMAN, BRIAN, TREASURER (End: 12/26/2012) Doing business as MATVEY CONSTRUCTION INC WA UBI No. 602 080 798 1912 S. 146th Street SEATAC, WA 98168 253-327-1650 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MATVECI991 CB Effective — expiration 02/02/2001— 09/29/2017 Bond Contractors Bonding & Insurance Co Bond account no. SI7209 $12,000 00 Received by L&I Effective date 08/28/2010 09/18/2010 Expiration date Until Canceled Bond history Insurance Kinsale Insurance Company Policy no. 0100043134 $1,000,000.00 Received by L&I Effective date 10/03/2016 09/27/2016 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602080798&LIC=MATVECI991 CB&SAW= 6/16/2017 MATVEY CONSTRUCTION INC° Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 16-2-23305-8SEA Complaint filed by SOUND HOUSING LLC 09/27/2017 Dismissed Complaint against bond(s) or savings SI7209 Complaint date Complaint amount 09/30/2016 $0.00 Cause no. 16-2-19378-1 SEA Complaint filed by MICHAEL ROSS Complaint date 08/19/2016 Cause no. 16-2-08722-1 SEA Complaint filed by J SCOTT USELDING Complaint date 04/19/2016 Cause no. 11-2-13191-8 Complaint filed by KIMBERLY KIDD JEFFERY Complaint date 09/19/2011 L&I Tax debts Open Complaint against bond(s) or savings SI7209 Complaint amount $0.00 Dismissed Complaint against bond(s) or savings SI7209 Complaint amount $0.00 Dismissed Complaint against bond(s) or savings SI7209 Complaint amount $2,500.00 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts Account no. 217,351-02 Doing business as MATVEY FOUNDATION REPAIR Certificate of Workers' Comp Coverage Account no. 641,468-00 Doing business as MATVEY FOUNDATION REPAIR Certificate of Workers' Comp Coverage Call L&I account representative for account status. Account is current. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602080798&LIC=MATVECI991 CB&SAW= 6/16/2017 MATVEY CONSTRUCTION INC Track this contractor ) 0 Workplace safety and health No inspections during the previous 6 year period. Page 3 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602080798&LIC=MATVECI991 CB&SAW= 6/16/2017