Loading...
HomeMy WebLinkAboutPermit D17-0171 - ALLEN INSTUTUTE - STORAGE RACKSALLEN INSTITUTE 1110 INDUSTRY DR D17-0171 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2523049071 1110 INDUSTRY DR Project Name: ALLEN INSTUTUTE DEVELOPMENT PERMIT Permit Number: D17-0171 Issue Date: Permit Expires On: 8/14/2017 2/10/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: BKM TUKWILA 117 LLC 111 THEORY STE #250 , IRVINE, WA, 92617 MIKE SORENSON 1100 SW 7TH ST , RENTON, WA, 98057 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST, RENTON, WA, 98055 NORTHWH275JF Lender: Name: ALLEN INSTITUTE Address: 1110 INDUSTRY DR , TUKWILA, WA, 98188 Phone: (206) 818-4488 Phone: (206) 255-0500 Expiration Date: 10/9/2017 DESCRIPTION OF WORK: SUPPLY AND INSTALL NEW RACKING & SHELVING. PLEASE SEE ATTACHED FOR BUILDING, RACK, LOCATION, SPECIFICATIONS AND COMMODITY INFORMATION. Project Valuation: $10,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $515.95 Occupancy per IBC: S-2 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: o Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: LoiL Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Nam /I ��grjf c�r� P/y/ 2/ Date: This permit shall'become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 0 0 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 13: Maintain fire extinguisher coverage throughout. 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit. Center . 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://Www:TulcWilaWA.gov CONSTRUCTION .PERMIT APPLICATION. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or.by fax. **Please Print** . LOCATION Site Address: • ' 1 n k 5- J Tenant Names. 4//. el sc‘/-1A Name: w; l� /17, .t t- . . Address: City: Xi.. v Stater Zip:9 �f'7 Address: 1 (. City: 7 1.. State: Zip Phone:.. gre_ 7 7 Fax :",i_Pd Li' 1 ie6 Email:, re(G 4,s Cis GENERAL' CONTRACTOR INFORMATION Company NameivorA‘,44-Is ,t� J%64,/'f Address::(/UO Xv. City: . State: Zip. Phone: i ?.54-' C? Fax tin. 6996 Contr Reg No.A 1Exp Date: < fiG% ( li �'�f G. Tukwila Business License No.:5.:D y King ,Co Assessor's Tax No:: Suite Number: ( . ' Floor:. New Tenant: Yes ❑ ::No ENGINEER OF RECORD OF RECORD , , ,: ' • _ _. ,.::.. n ; ,z7. • (.Hl tECT Co any y Name:. State:lk Zip: Architect : i e: (o City: Address: State: I Zip: ooy Phone :/8' V'" �op City: Email: State: Zip: Phone: :. Fax: Emai • ENGINEER OF RECORD -,, .. tx i .i i a ;'` Company Name: Address: Art<< . r biggeyiy 0, Engineer Name: State:lk Zip: Address: if ( w. (o City: State: I Zip: ooy Phone :/8' V'" �op Faxjg ,)'i_eO . 3 g,i7 Email: LENDER/BOND ISSiJED (required for prolectsS5,000 or eater er .RCW.19.27 Name: Address: 2i A City:: State:lk Zip: H:Wpplications\Forms-Applications on Line \2011 Applications\Pemut Application Revised - 8-9-11.doex Revised August 2011 • bh " rBIJII:DIN G PERMITINFC '�Fi;�Mda.�"--...,�'r�yj.�-S y vrt'.F"�wi ,:f ��Ny,�k'��.,',s+�•+ Valuation of Project (contractor's bid price): $ . / O 60' Describe the scope of work (please provide detailed information): " P 4,e 0 0141v Will there be new rack storage? [; Yes • Existing Building Valuation: $ ins AeLw t`4C/Cf Vii... _) .. .� l eQ.; I�'4 c D Gam. Zr+ t Pre 1=1.. No If yes; a separate permit and plan submittal will be required. • P o ide All B d g Are,as ><n Sq a giotag Bel y' ,�±h�,�c`:a"§✓� :?, a*`v.;T Y_ x x w �li '`?ay'77 t', .4,.1,;,..., , Existmg, � ;,-�-° � `;,'qG' IntenorRemode¢Sructure. aAEddihnlt1''"ri `i'.c.7i,X xisting�:# ',R=' :New �"s ".t . of $;4 r •onstru on eOGeupaneyp m _C�K�4 -re o4 , r er., E SIB ,=f -Crr 11looi.,4� 3rd'Fltior • Basement ..4.; gc: `�,'-3 }Ac e`ssory>St uc""�„ture* �AttachedGarag; ipetach aged 3Attaehed Car —8 . I z .Deta'ch_ arport" r r� x S- ouered Deck A. ^�,,,,, Atir a e' dOak PLANNING DIVISION: Single :family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For'an Accessory dwelling; provide She following: Lot Area (sq ft): . . Floor area of principal dwelling: .. Floor area of accessory dwelling: ' *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact Handicap: Will there be a'change in use? . ' ❑ Yes No If "yes", explain: 'FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ' ❑ Automatic Fire Alarm VNone ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ' Yes If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ Onsite Septic System - For •on-site septic system, provide 2 copies of a current septic design approved by King County Health .. ,.•_Departmeiit. • ' H:Wpplcations\Forms-Applications On Line\2011 Applications\Pennit Application Revised --9-.11.docx "Revised: August 2011. bh . 0 IT ICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI GENT: Signature: Date: Wg>/c)-0 Print Name: Day Telephone: P06- Sl 0 Mailing Address: ((°O J t 7,41 J'? ' R Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT PermitTRAK QUANTITY I PAID $515.95 D17-0171 Address: 1110 INDUSTRY DR Apn: 2523049071 $515,95 Credit Card Fee $15.03 Credit Card Fee R000.369.908.00.00 0.00 $15.03 DEVELOPMENT $486.32 PERMIT FEE R000.322.100.00.00 0.00 $292.01 PLAN CHECK FEE R000.345.830.00.00 0.00 $189.81 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $14.60 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R11792 0.00 $14.60 $515.95 Date Paid: Thursday, June 22, 2017 Paid By: MIKE SORENSON Pay Method: CREDIT CARD 07609D Printed: Thursday, June 22, 2017 3:49 PM 1 of 1 cPWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1 Project: Aj Ij sT7°_'i> Address: /1/0 iNoasTRy DQ. Type of Inspection: ,3L)/LPM6- FlN// L Date Called: Special Instructions: ' CA-LL,g,-4,R Date Wanted: e'--1 g-- 17 er p.m. Requester: ®A) Phone No: SCP 3- 37 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: /0 J� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di 7-0171 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .. 71. c1J ), /`''-' -u .A . Type of Inspection: i Cbj,1& // L Address: /NO i.AThri-zY -De Date Called: Special Instructions: _ Date Wanted: 4/7 %1 ^7 a.m. p.m. Requestf ,/ VVj :- / j /SAi Phone No: ZCJ6 - Si l)+- R-37 CALL ri). ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: .Af T%0 -e 77) CAArCg j7 Inspector: Date: 9 _ 7 -/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO, INSPECTION RECORD Retain a copy with permit 1)17 palI PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:� �� / Ty of Inspection: tAtiv Je- f L 4LL6"/ 1A617Tv Address: I JO ikil vcriz.V b ' Date Called: J Special Instructions: ef4U- / / sS Date Wanted:' 5' � i 7 a.m. Requester: Allred /4A LI— Phone No: 42 -s` -- s 1c(_ Approved per applicable codes. D Corrections required prior to approval. COMMENTS: D S y ,1A6Pezr! )Q6's,c4-1-& ,fte- 7,xx-Rione Inspector: !J. Date: ir/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dr/ - d ll PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A it xi" rAS-i-Xle Sprinklers: Type of Inspection: R A, 4_ Address:. Suite #: ///0 /Adlvs -y Or. Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. t� Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: —g- j Date: 9/7/) -7 Hrs.: f . 4 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ti 0111 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575=4407 Project: /44 Sprinklers: Type of Inspection: Address: . Suite #: /1(0 /nAI7441 Contact Person: Special Instructions: - / Phone No.: Approved per applicable codes. a ir Corrections required prior to approval. COMMENTS: t /a :/CS ."l//%4, -- £?/L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: „cor/4„3-Z Date: 9/%// 7 Hrs.: /< a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood September 6, 2017 File No. 17-581 Building. Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Allen Institute 1110 Industry Drive D17-0171 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION.INSPECTiON AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to • advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. Proprietary anchor .installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President RECEIVED CITY OF TUKWILA SEP 0 6 2017 PERMIT CENTER CC: Northwest Handling Systems, Inc. -Tony Johnson, Mike Sorenson Tel: (425) 881-5812 Fax (425) 881-5441 •7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 Field Report Report #: 70569 A A R Testing; Laboratory, Inc. 7126180th Ave.N E,, park 150,78uite 0181, Redmond, WA 98052 Phone 425.881.5812 Fax '425.881.5441 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055-2939 Contact: Tony Johnson Project Number: 17-581 Permit #: D17 0171 Project Name: .Allen Institute Address: 1110 Industry Drive Inspection Performed: Proprietary Anchors Date: 8/28/2017 Time: Temperature: Anchor bolts for pallet racks per drawing D1. Verified installation of Hilti KBTZ anchors, 1/2" x 4 1/2" with 3 1/4" embedment, torqued to 40 ft. lbs. All installed per ESR 1917. RECEIVED CITY OF TUKWILA SEP 0 6 2017 PERMIT CENTER Distribution: Distribute Client [l Distribute Contractor Distribute Engineer [] Distribute Owner 1 Distribute Municipality ;' Distribute Other [ j Distribute Architect i[i Distribute Other Inspector: Trow, Michael Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden NORTHWEST HA N D LI N G SY S TEMS. I N C. The Material Handling Experts FIL 1100 SW 7th St Renton, WA 98057 (425) 255-0500 ph ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1110 8 1112 Industry Drive TENANT NAME: The Allen Institute DATE: May 31, 2017 APPLICANT: Mike Sorenson / (206) 818-4488 1. Load application and rack configuration drawings attached. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Special inspection of anchor bolts will be performed by AAR Testing Lab. PO Box 2523 Redmond, WA 98073 425-881-5812. 5. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 6. Commodities stored in racks; Laboratory equipment. Composed of plastic and light steel materials. Stored in wood crates and cardboard boxes on wire mesh rack decks. 7. Sprinkler System Information: No sprinkler system. 8. Building exits indicated on attached drawing. 9. Ceiling height: 14'. 10. Maximum storage height: 11'. ot7 RECEIVED CITY OF TUKWILA JUN 22 2011 PERMIT CENTER BY G. OHANIAN DATE .6-15-17 SUBJECT RACK DEOI(N & ENG4INEERIN(t do. 412 WEOT BROADWAY, OUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD -19029 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: ALLEN INSTITUTE 1 1 1 0 INDUSTRY DRIVE TUKWILA, WA 98188 PER IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3 RMI/ANSI/MH 1 6.1 :2012 STORAGE RACKS CAPACITY: 3000 #/LEVEL PALLET RACK 250 #/LEVEL SHELVING CALCS. 1 THRU 6 DRAWINGS: RD -19029 EXPIRES 12-26-17 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032017 City of Tukwila BUILDING DIVISION t) k`al-- 0 rl 1 RECEIVED CITY OF TUKWILA JUN 22 2017 PERMIT CENTER BY G. OHANIAN RAdK DEOI(N & ENG�INEERIN( CO. DATE 6-15-17 SUBJECT 412 WEP1T BROADWAY, QUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 2 JOB NO.. RD -19029 96" 44" BEAM DESIGN t=0.06" 2 3/4" PALLET RACK Ix=1.63 X Sx =.77 FY= 55 KSI. SEISMIC DESIGN Sosxl V_ Rx 1 .4 xW c' , SIDE VIEW LOAD PER BEAM + 25% IMPACT LOAD (3.OKx.88)+(1.5Kx.25) = 3.0— 1.5K 2 BEAMS M= 82 -18"K S R= .55<.77 _ 5xwL4 L 384.1 x•E —'36"< 180 =.53" IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2012 S Ds =0.97 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PRODUCT LOAD LOAD PER COL — 3x3.0 K =4,5 K 2ca. LONGIT. SEISMIC P=.2DL+ (4.5Kx0.75)=3.6K 19K W=•20L+ (4.5PLx0.67)= 3.2 K 12K 3.9 V = .37 K :V 06K 6.5 LONGIT. V = .56K TRANS. .37K 3.9"K 6.5"K 7.8"K 7.8 K BY G. OHANIAN DATE 6-15-17 SUBJECT RACK DEOI(N & ENdINEERIN( CO. 412 WET BROADWAY, �1UITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 3 JOB NO.. RD -19029 COLUMN DESIGN x- t=.070" COMBINED STRESS RATIO Pex= rr2E.lx =99.0 (KL)2 ax=1- Clcx = .94 Pex F =55 KSI Y- Ae=.62 I x=.95 Se=.6 rx=1.2 ry=1.1 Qc=1.8 Qb=1.67 Cmx=.85 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .19 K KL _44x1.2 rx 1.2 =44 KL_30 ry 1 .1 - 27 Mn=Se.Fy= 35 f2c.P + Qb.Cmx.M =•56<1 Pn Mn.ax (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT -TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x1 x65=2.3 K BEARING CAPACITY OF COL. HOLE 7/16"0 RIVET A=.1 Fy=79Ks1 Pa = .1x79x.4 = 3 K Ma = (2.3Kx4")+(1.1 Kx2") = 11.4K 3 PIN CONN. CONN. M = .01 xwl 2= 1 .4"K END M= 7.1"K SEISMIC M = 8.5 ..K TOTAL L 2 Fe=(K xE = 150 rx 2 F n=F y(.658 x c )=47* KSI Pn= Fn .Ae = 29.0 K 7.8"K X=N/Fy/Fe = 0.60 Nc<1.5 8"x5"x3/8" BASE PLATE 6.5 'K 7.1 "K -I � ® 7.1 "K 7.8 'K BY G. OHANIAN DATE .6-15-17 SUBJECT RAdK DEOI(4N & EN(INEERINd do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 4 JOB NO.. RD -19029 OVERTURNING 3.6K 3.6K x MOT=.56Kx2 x147"x0.66=108. "K � `J COL. MR = 3.6 Kx44"= 157 K 56K 56K 0 NO UPLIFT 44" LOAD TO DIAGONAL P = .56 Kx2 x52 = 1.2 K COL. 42 FY =55 KSI Ae=.26 rx =.48 L= 52" P0= 3.1 K CHECK WELDS Pn= (1_.01L)L.t.F, = 5.36K f2= 2.55 Pn = 2.1 K x2 = 4.2K 0 SIDES CHECK SLAB 3600 = 3 6 0' 1000 J518=23" 3.6x144=5180 M= (122 ) x1000x 2 x12=2344 # S= 12x62 = 72 6 2344 = 33 <1.6 J 2500 =80 72 0 0 TOP LEVEL LOADING W= 0.20L+1.5LL= 1.7 K LOAD PER COL. V= .30 K MOT =.30Kx2 x132"=78 COL. MR = 1.7 Kx44" = 75 "K UPLIFT = 78-75 —.07 K 44' BOTH SIDES TYP> 1 /8 V1 5" • 10 t=.06" 3600 # 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL BY G. OHANIAN DATE 6-15-17 SUBJECT RAdK DEOI(N & EN(INEERIN(1 do. 412 WET BROADWAY, SUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 5 JOB NO. RD -19029 co 60" "SS" TYP. "SS" BEAM 1 3/32" SHELVING 1 X=.22 Sx=.12 FY= 36KSI. LOAD PER COL. = 3x.25 K -.38 K 2 COL. P=.1 DL+ W .1DL V= .04 K 04K (.38Kx0.75)=.38K (.38PLx0.67)= .35 K 36" S TYP. SIDE VIEW 250 # / LEVEL 125 # / BEAM M= 60"x.13 K = "K 8 S R= 120"K ,..04<.12 0 BY G. OHANIAN DATE 6-15-17 SUBJECT RAdK DEOIC N & ENGtINEERINC do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 6 JOB NO. RD -19029 COLUMN DESIGN 3 1/4 COMBINED STRESS RATIO Pex,_ 7r2E.lx = 9 (KL)2 ax=i QcP =.92 Pex FY =36Ks1 Ae=.28 Ix—.07 Smin=.07 rmin=.51 KL = 28x1.7 = 93 rmin .51 Mn=Se .Fy=2.5 Qc=1 .8 Oc.P+ S-2b.Cmx.M =.72<1 P„ Mn.ax f)b=1.67 Cmx=.85 OVERTURNING = .04K x2x84"x.66 = 4.4 "K MOT MR = .38Kx36"= 13.7"K NO UPLIFT BASE PLATE T=0 ANCHOR SHEAR = .04 K .38K .38K .04 K .04 K (1)-3/8"0 ANCHOR PER BASE PL., 2" EMB. HILTI KWIK BOLT—TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION M _ 1.0+.5 = .75"K CONN.— 2 VR VET _ .25z� 3.1 4 x80x.4=1 .5 K Ma = 1.5Kx1.5"=2.3 "K CONN 36" co 2 Fe= Tr XE2=34 KL)rx 2 Fn=Fy (.658 �c )=24Ksi Pn=Fn .Ae = 6.6 K 0 ILO .25"0 RIVET F =80 KSI = -\/Fy /Fe = 1 Xc<1.5 July 14, 2017 C City of Tukwila Allan Ekberg, Mayor Department of Community Development MIKE SORENSON 1100 SW 7TH ST RENTON, WA 98057 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0171 ALLEN INSTUTUTE - 1110 INDUSTRY DR Dear MIKE SORENSON, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. The classification of the commodities has been determined to be Group A plastics. Therefore, storage height 6 ft. and greater is considered high -piled combustible storage. International Fire Code Table 3206.2 requires smoke and heat removal (smoke vents). Please show location of existing/proposed smoke vents on the drawings. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely Rachelle • iple Permit Technician File No. D17-0171 6300,Snuthren.tpr Rnulevnrd .G/ito #1nn • Tvlru,iln Wnchinotnn QR1RR . ns -d21_2.' 7n . F, . on/ 421 2#.c HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0171 DATE: 07/26/17 PROJECT NAME: ALLEN INSTITUTE SITE ADDRESS: 1110 INDUSTRY DR Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works El �-� c x'3''7 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 07/27/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 08/24/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 9ERMIT COORD COPY: C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0171 DATE: 06/22/17 PROJECT NAME: ALLEN INSTITUTE SITE ADDRESS: 1110 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: m A'Wc ( (7 Building Division Public Works II�102 141 Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/27/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/25/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1 Departments issued corrections: ri - Bldg 0 Fire Ping ❑ PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov VISION UBMITTI CORRECTION Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. S 3117 ea(': l Date: 7// ( 7 Plan Check/Permit Number: D17-0171 O Response to Incomplete Letter # ® Response to Correction Letter # _1_ ❑ Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: ALLEN INSTITUTE Project Address: 1110 INDUSTRY DR RECEIVED CITY OF TUKWILA JUL 262011 PERMIT CENTER Contact Person:/-/(rke_ ; &4SC Phone Number: e2-(9(� �''g- ifRe Summary of Revision: k/4 cOr241:o/ wl f «>w, F7341017 " iz1/4./ S tc citoi 4((2,\ 7 , / (.I✓ ccl s -C c -°.N ,vCdik 4 (»-2..T T. C.o Brod, :/7C;r t' is o. 1 !�`L . �(awrr ; 1-Ciooroi�r1 2,ivy".€ ,I, CO or orin+6l ,n�eTJ ,deeIi (nil ver -7 //��'iiit2 fit ti S'�i'� /, P1 �7`i c Co eviatn�2rX Size-. coil L040,1'7 `h'v-(,� Ort (c, . Rex � -w+ v'a -ft c:, r22ve-r-f J2� a r (9/ :10 (c� � (Q.�2 �co�Q / C Sheet Number(s): �" "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: (/ ra— Entered in TRAKiT on --7-41P "17 C:\Users\Rachelle-R\Desktop\Revision Submittal Form - D16-0305.doc Revised: August 2015 NORTH WEST HANDLING SYS INC Hoene Espanol Contact Safety & Health Claims & Insurance ® � Washington State Department of ILI Labor & Industries Search L&I AZ Index Help Page 1 of 2 My L,&I Workplace Rights Trades & Licensing NORTH WEST HANDLING SYS INC Owner or tradesperson Principals FRANCK, JAMES JEROME, PRESIDENT KOSTY, CLARK RANDOLPH, TREASURER THOMAS, KEVIN A (End: 09/28/2011) Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100SW7TH ST RENTON, WA 98055-2939 425-255-0500 KING County Business type Corporation Governing persons JAMES J FRANCK CLARK R KOSTY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973-10/09/2017 Bond ............... Travelers Cas & Surety Co Bond account no. 81 SI03354822BCM Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/09/2001 10/01/2001 Expiration date Until Canceled Insurance ............................... Travelers Indemnity Company Th Policy no. Y6302C242044TIA16 $1,000,000.00 Received by L&I Effective date 09/30/2016 10/01/2016 Expiration date 10/01/2017 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 8/14/2017 Help us improve NORTH WEST HANDLING SYS INC Savings ..... No savings accounts during the previous 6 !period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 329,999-00 Doing business as NORTHWEST HANDLING SYSTEMS INC Estimated workers reported Quarter 2 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / TERRI MADISON (360)902-4654 - Email: KIRT235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................................................ No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/21/2015 Inspection no. 317936474 Location 1100 Sw 7th Street Renton, WA 98055-2939 Inspection results date 08/21/2015 Inspection no. 317937073 Location 1100 SW 7th Street Renton, WA 98055-2939 Violations Violations Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington: Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 8/14/2017 C --F\\ 7'-11" 6'-1" VX96 X96 X96 dX96 t cX96 'I - /P.1' -11" r /7'-11" 10'_7" d/X96 1X96 1X96 10'-0 5/8" �/X96 1X96 ddX96 ddX96 d/X96 1X96 1X96 10'-0 5/8" �/X96 d X96 1X96 z_. 7' 5„ PLAN VIEW SCALE: 1/4" = 1'-0" 0 (0X N) 0 co x SEPARATE PERMIT REQUIRED FOR: (/Mechanical [ iectricai 011aiumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. G 11 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted cote or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 03 2017 VW(' City of Tukwila BUILDING DIVISION CITY OF TUKWILA JUN 22 2017 PERMIT CENTER SHEET NUMBER BOTH SIDES TYP. t=.06" SEC. A—A 1/4"o SAFETY LOCK (1000 # CAPACITY) P 9 P 9 9 9 9 (2)-1/2"o ANCHOR BOLTS PER BASE PLATE 3 1/4" EMB., (SEE NOTE NO. 4) BASE PLATE DETAIL BRACING DETAIL 7/16"o RIVET ASTM A576 -90B HOT—WROUGHT UNS G10100 GRADE C-1010 t=3/16" 3 PIN CONNECTION GENERAL CONFIGURATION 1/4"o RIVET 1/4"o SCREW "SS" BEAM 14 GA. Fy=36 KSI T—POST 14 GA, Fy=36 KSI L—POST 14 GA. "JL" POST BASE PLATE (1)-3/8"0 ANCHOR PER BASE PLATE 2" EMB. (SEE NOTE NO. 4) "L" POST BASE PLATE (1)-3/8"o ANCHOR PER BASE PLATE 2" EMB. (SEE NOTE NO. 4) REVIEWED FOR 'CODE COMPLIANCE APPROVED AUG 032017 BEAM TIE ONE PER LEVEL City of Tukwila BUILDING DIVISION SHELVING COLUMN BASE PLATE DETAIL BEAM CONNECTION NOTES; 1—DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2015, ASCE/SEI 7-10, ACI 318-14, RMI/ANSI MH 16.1:2012 2—STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) 3—NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #01649 (E70XX ELECTRODES) 4—ALL ANCHORS HILTI KB TZ ESR 1917 SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6—STORAGE RACK CAPACITY: 3000 #/ LEVEL AT PALLET RACK 250 #/ LEVEL AT SHELVING 7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (SEE NOTE NO. 6) 8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10'-0" OF HEIGHT 9—THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10—STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY b o RECEIVED CITY OF TUKWILA JUN 22 2017 PERMIT CENTER RACK DESIGN AND ENGINEERING 412 WEST BROADWAY SUITE #204 GLENDALE CA. 91204 SCALE: NONE DRAWN BY: A.KH. DATE: 6-15-17 PROJECT: PALLET RACK SIDE VIEW SHELVING SIDE VIEW ALLEN INSTITUTE 1110 INDUSTRY DRIVE, TUKWILA, WA 98188 DETAILS JOB NO. RD -19029 STORAGE RACK SHEET NO. EXPIRES 12-26-17