Loading...
HomeMy WebLinkAboutPermit D17-0187 - OYLER RESIDENCE - REROOF AND REMODELOYLER RESIDENCE 13348 34r" AVE S EXPIRED 04/22/2019 D17-0187 • Parcel No: Address: Project Name: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 7358600125 13348 34TH AVE S OYLER RESIDENCE DEVELOPMENT PERMIT Permit Number: D17-0187 Issue Date: 8/1/2017 Permit Expires On: 1/28/2018 Owner: Name: Address: Contact Person: Name: Address: OYLER LANCE 13348 34TH AVENUE SOUTH , TUKWILA, WA, 98168 LANCE OYLER 13348 34 AVE S , TUKWILA, WA, 98168 Phone: (206) 714-7927 Contractor: Name: OWNER AFFIDAVIT - LANCE OYLER Phone: Address: License No: Expiration Date: Lender: Name: LANCE OYLER Address: 13348 34 AVE S , TUKWILA, WA, 98168. DESCRIPTION OF WORK: NEW ROOF, REPLACEMENT WINDOWS AND DOORS, REMODEL KITCHEN AND BATH WITHIN EXISTING ENVELOPE OF RESIDENCE. 42 SQ FT ADDITION TO DETACHED UNHEATED SHOP Project Valuation: $17,083.20 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $772.78 Occupancy per IBC: R-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: O C7 Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: ,Itu Vibe Date: I hearby certify that I have read and examined this permit and knovJ'fhe same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 0201 FOOTING 0409 FRAMING 0606 GLAZING 0401 ROOF SHEATHING 0603 ROOF/CEILING INSUL 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUKTnA Community Develophiwit Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila; WA 98188 http://www.TukwilaWA.gov Building Pe t No. h l-- 0 (3 7 Project No. Date Application Accepted: 7 11- 1 7 Date Application Expires: l I t 9 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: IS -3418 311AVE S Tenant Name: /WA King Co Assessor's Tax No.: Suite Number: PROPERTY OWNER Name: 44/tiLitg Oiel „- C� /CDN7g Name: ., t E 0 y iz /�S City: T�k-w 1 LA State: IIA Address: /33Y8 3y./ AveS Phone: Fax: City: i �vk►..l t � /.c.LState: t /j� Zip: / Zi g8i6A CONTACT PERSON — person receiving all project communication Name: 44/tiLitg Oiel „- C� /CDN7g Address: /33418 le/P/ 4 -yr Address: /�S City: T�k-w 1 LA State: IIA q Zip: 18r68 Phone: Fax: State: Email: Phone: GENERAL CONTRACTOR INFORMATION Company Name: 01.1 C� /CDN7g Tog. Address: Phone:Fax: Zcc 7179 z7 Email:LQYLRe 4 _Axed/11 ngF (01,4 City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: City: Tukwila Business License No.: State: Zip: HAApplications On Line\2012 Applications'Permit Application Revised - 2-7-12.docx . Revised: February 2012 bh Floor: New Tenant: ❑ Yes ®.. No ARCHITECT OF RECORD Company Name: /416.L. AgL40T5ciU2F. Architect Name: LA.1%ic r DYc Address: )33'j 3e0,1 AveS 7 State: t / A Zip:?9/ City:-7—ust4illA Phone:Fax: Zcc 7179 z7 Email:LQYLRe 4 _Axed/11 ngF (01,4 ENGINEER OF RECORD Name: RIVALA4Akse DY/ a— Company Name: , 1/q, , /� City: 'TugiAl ' State: 414 Zip: q6/66 Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: RIVALA4Akse DY/ a— Address: 13348 704 S City: 'TugiAl ' State: 414 Zip: q6/66 Page 1 of 4 BUILDING PERMIT INFORMATION -206-431-3670 Valuation of Project (contractor's bid price): $ 5,0 Existing Building Valuation: $ 77000 �•IA ..I L.a u J _ :r Describe the scope of work (please provide detailed information): _TheiLS R Moptt_ A-17Gtifr1 t 1 1411 6/5711-44 1-11e0Lnft-. CJIt1 P 5iop ADP 171014. Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: e Lot Area (sq ft): 309.5 Floor area of principal dwelling: 653./ Floor area of accessory dwelling: AO *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: / EX/517W67 Compact: 0 Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor w. ] O \' l� g p g-3 2nd Floor . 3rd Floor ( Floors thru / — Basement — Accessory Structure* O* 210 7l5 / \i5 0 Attached Garage / Detached Garage / Attached Carport / Detached Carport / Covered Deck / • Uncovered Deck /1/6. v o , PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: e Lot Area (sq ft): 309.5 Floor area of principal dwelling: 653./ Floor area of accessory dwelling: AO *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: / EX/517W67 Compact: 0 Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFOPIATION — 206-433-0179y Scope of Work (please provide detailed information): ' /6 .1 Z'3fZ �t',��NI,ENIT �1/FI s Z+ -i2)12-5 iel%a t %./ 76// &,,k//.x 4V5i7147 WO/7g- uMEA'l'17 sy4p App/ T/0 Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila g... Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline M ...Valley View 0...Renton 0 ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which applv): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) 0 .. Bond D. Insurance ❑... Easement(s) Proposed Activities (mark boxes that annlv): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ .. Total Cut ❑ .. Total Fill Zcubic yards I cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control 0 .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0 .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ 0 .. Water Main Extension Public 0 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage 0...Abandon Septic Tank ❑... Curb Cut 0...Pavement Cut 0...Looped Fire Line WO # WO # WO # Private 0 Private 0 0...Grease Interceptor 0... Channelization 0... Trench Excavation 0... Utility Undergrounding (2) . " WO # (3) (2) " WO # (3) ❑ .. Deduct Water Meter Size " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water 0 .. Sewer Monthly Service Billing to: Number of Public Fire Hydrant(s) 0 .. Sewage Treatment Name: Day Telephone: Mailing Address: City Water Meter Refund/Billing: Name: Mailing Address: State, Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by 'the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORt1UTHQRIZED AGENT: Signature: Print Name: Mailing Address: Lk-46g6Yi-E/2 /3348 3glrnA-ve S Date: 7/10/// Day Telephone: ZOI 7/j 7727 ting State Zip 70444 1111 City H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY • PAID $479.03 D17-0187 Address: 13348 34TH AVE S Apn: 7358600125 $479.03 DEVELOPMENT. $456.43 PERMIT FEE R000.322.100.00.00 0.00 $451.93 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.60 TECHNOLOGY FEE_ TOTAL FEES PAID BY RECEIPT: R12033 R000.322.900.04.00 0.00 $22.60 $479.03 Date Paid: Tuesday, August 01, 2017 Paid By: LANCE OYLER Pay Method: CHECK 1508 Printed: Tuesday, August 01, 2017 11:49 AM 1 of 1 cSYSTEMS Cash Register Receipt City of Tukwila Receipt Number R11893 DESCRIPTIONS PermitTRAK I ACCOUNT 1 QUANTITY PAID $293.75 Address: 13348 34TH AVE S Apn: 7358600125 $293.75 DEVELOPMENT $293.75 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11893 R000.345.830.00.00 0.00 $293.75 $293.75 Date Paid: Tuesday, July 11, 2017 Paid By: LANCE OYLER Pay Method: CHECK 1507 Printed: Tuesday, July 11, 2017 2:10 PM 1 of 1 CR SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (>4 L.€2, Type of Inspection: fiL Nil Address: Iiib 4 O 1444. Date Called: Special Instructions: Date Wanted: a.m. _ Requester: Phone No: Approved per applicable codes. COMMENTS: 114 lorrections required prior to approval. U40 6:46 Inspector: Dater L1 REINSPECTIONRE IRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1)}7_o 17'7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: M/6 °Frii Ave a Date Called: Special Instructions:� C d f� 6 Date Wanted: 71-25--46 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Forimiz f" `wle2 "'zoo / ` L.,t 0146. . L Ox- 0,/ - t • t rig 11"rckJrrl �, <rs, 1SA1-- resLet 2) s--px_ e_Cczzcevtc,AL Pinsvd-e, [IA , vtS p 10,1 Inspector: Q�4 Date:C/_ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 D17-ole`7 Project_Type * L FR RE6-)D,eNCF Type of Inspection: Rtre S F EAT -Hi .i &-- Address: y83VTN Av6 a, Date Called: Special Instructions: Date Wanted: /0 -2.,5m -i % 6.' p.m. Requester: Phone No: 14 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: e,k—ROor; 7J Inspector: S Date: -/-Z('-i °7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit b) 7- e/6" PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 \kt Project: 0-ite12. OeSibetia- 'Type of inspection: 6- ziA16- Address: 1 3Lib 3071,4%/E 3 Date Called: b 4):4iNs- ot. Special Instructions: Date Wanted: /1 tipwn./G Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: b 4):4iNs- ot. 9 0106 -4 -ns Aite-T"CemiAle- Inspector: Date: 4f 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 \kr Project: °/ OYU-le T. �e^of Inspection: Address:,�, i /3346 31/ s Date Called: /A Special Instructions: ' Date Wanted: 47q j/7 p.m. Requester: Aicer Phone No: 26- 714-1 74121 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /A Iger S I! 7 '" Y AT' p / H y C 4W or /ZC44 - a4d Afi eek-rir., r Inspector: 47)41A-1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3/1/2019 City of Tukwila Department of Community Development LANCE OYLER 13348 34 AVE S TUKWILA, WA 98168 RE: Permit No. D I7-0187 OYLER RESIDENCE 1334834AVE S Allan Ekberg, Mayor Jack Pace, Director Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/22/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. ' -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/22/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0187 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 0 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director October 26, 2018 Lance Oyler 13348 34th Ave S Tukwila, WA 98168 RE: Request for Extension #1 Permit Number D17-0187 Dear Mr. Oyler, This letter is in response to your written request for an extension to Permit D17-0187. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through April 22, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician qrit File: Permit No. D17-0187 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 0 October 14, 2018 Permit Number D17-0187 13348 34th Ave S. Tukwila, WA 98168 Attention Bill Rambo. Q RECEIVED OCT 18 2010 COMMUNITY DEVELOPMENT I am writing to file a 180 -day extension for building permit D17-0187 as allowed by the Tukwila Building code. The delay in completion of work is due to professional and personal reasons over the summer limiting my time to complete the required work. I have gotten back on track on my work and expect to have the next inspection in the month of November. If you have any questions, feel free to contact me at: 206 714 7927 loyler@wol-architecture.com Thank you, Lance Oylerq,, Request for Extensior. # 1 Current Expiration Date: ! O e Extension Request: Approved for / Cd days Denied (provide explanation) 1 Signatures" .nitials 9/5/2018 0 0 City of Tukwila Department of Community Development LANCE OYLER 13348 34 AVE S TUKWILA, WA 98168 RE: Permit No. D17-0187 OYLER RESIDENCE 13348 34 AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/22/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/22/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0187 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 3/1/2018 0 City of Tukwila Department of Community Development LANCE OYLER 13348 34 AVE S TUKWILA, WA 98168 RE: Permit No. D17-0187 OYLER RESIDENCE 13348 34 AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/23/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building. Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/23/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0187 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0187 PROJECT NAME: OYLER RESIDENCE SITE ADDRESS: 13348 34 AVE S X Original Plan Submittal Response to Correction Letter # DATE: 07/11/17 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: k\NO 110 wilding Divisi n POA IA 41M Public Works tle Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 07/13/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: - rdlin�s DUE DATE: 08/10/17 Approved with Conditions1'.( Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: L m- 01%1 STATE OF WASHINGTON) ) ss. COUNTY OF KING A»'-- YLEF- [please print name] , states as follows: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 17-- , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction ork. ` $%ON 'h, p� S N tlWASN; ill I„`��``� Owner/Owner's Agent* Signed and sworn to before me this 1 day oftaA uy+- , 20 11 . NOTARY PUBL C in a d for the State of Washington , ton ILA � g Residing at Name as commissioned: My commission expires: c; 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operationsbeing considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11.An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a Valid electrical contractor's license under chapter 1928 RCW't'hat.employs`a certified journeyman electrician, a certified residential specialty electrician, or an electrical°trainee meeting the requirements of chapter. 19.28 RCW to,perform plumbing work that is incidentally, directly," and immediately appropriate to the like -in-kind replace`mentof a• household appliance or other small household utilization equipment that requires limited electric Rower and limited waste and/or water connections. An electricaltrainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. SHEET DRAWING INDEX A1.0 A2.0 A2.1 A3.0 A4.0 A7.1 COVER SHEET/SITE PLAN HOUSE FLOOR PLAN/SCHEDULES SHOP PLANS, SECTIONS AND ELEVATIONS HOUSE STRUCTURAL PLANS HOUSE ELEVATIONS AND SECTION DETAILS EXISTING NEAREST FIRE HYDRANT, APPROXIMATE LOCATION BUILDING DEPARTMENT NOTES CONTINUED BUILDING DEPARTMENT NOTES WASHINGTON STATE ENERGY CODE NO ADDITIONAL HEATED AREA PROPOSED, REPLACEMENT WINDOWS AND DOORS IN EXITING HEATED BUILDING ENVELOPE SHALL CONFORM TO MINIMUM PRESCRIPTIVE REQUIREMENTS OF THE WSEC. STUD BAYS OPENED THROUGH THE COURSE OF CONSTRUCTION SHALL BE FILLED WITH NEW R-15 COMPRESSED BATT INSULATION. SCOPE OF WORK.: PROJECT OWNER: 30'-0" EXIST'G 5'-0" EXIST'G 5'-0" EXIST'G 10'-0" EXIST'G LANCE OYLER PROJECT ADDRESS: 13348 34TH AVE SOUTH TUKWILA, WA 98168 ASSESSOR'S NUMBER: VICINITY MAP INTERLAKEN ADDITION, BLOCK 10, LOT 15 ZONING: LOW DENSITY RESIDENTIAL REQUIRED SETBACKS: FRONT YARD 20'-O" REQ'D NORTH SIDE YARD 5'-0" REQ'D SOUTH SIDE YARD 5'-0" REQ'D REAR YARD 10'-0" REQ'D i. cork %„ S t.e.n St, T 128d1 $t ti - 5 513 th VI-. - - 1Yi 5132nd St 51331351.: -.51331351 s1 th 51. 5135th 5t-. - 5135th St Seafood ', 5 i36m sl :catuf Pork `^ N"j t " 5 138;5 St 5138tR5t SkoToc ,.Muteh Pat ern - m <' 51531135t 3142nd St Riverton — d - N n 5130th 51 m :, IN C } P r 9c + - i dth St `cl 9v 53301(5 St _ ,� 513',tT1.. n ; m �g2 JS t ,^ ` 4. '^ "y 3 - S 133rd St' .is_ - Q - "er7hsy 13348 34th Ave 5 stfrthgar3 . Pork Tukwila, WA 98168 5 13715 ft 5' �' 1i rc -Li RnFrtat Uast 5135th St .. Eco. Lodge Soots(ort No :S 14 t,th 51 po rth .n i 5141st 51 4 j '''.1.'''.1.c 4t'1la VER VC -o Rep'"yrc tfµ�✓p ''ky ' 599 sv�, f!a S 3'o > Foster 5137th 51^ 51 Ifith St. Gtf t+rF s 17,51. Inn 5 tt South 1'1 (156 '� f h lt. ? ya / i '-' 1 d ,z Fo:n.c,•;1t„a. t v t YV < i �1 f f' t 51Jattr St jib L� S i.. / 1. G C a' 'Sq EXISTING NEAREST FIRE HYDRANT, APPROXIMATE LOCATION BUILDING DEPARTMENT NOTES CONTINUED BUILDING HEIGHT: EXIST'G, NO CHANGE. LOT AREA: 6,020 SF BUILDING FOOTPRINT: EXIST'G HOUSE: (25'-11")(32'-11") = 853.1 SQ.FT. EXISTING DECK: (12'-3")(10'-7 1/2") + (4'-6")(3'-6 1/2") = 146.1 SQ.FT. EXISTING STOOP AND STAIR: 3'-8 1/4"x7'-10 1/4" = 28.8 SQ.FT. EXISTING SHOP: (12'-0“)(20'-0") = 240.0 SQ.FT. SHOP ADDITION: (2)(7'-11")(3'-0") = 41.5 SQ.FT. TOTAL: 853.1 + 146.1 + 28.8 + 240.0 + 41.5 =1,309.5 SQ.FT. LOT COVERAGE: 1,309.5/6,020 = 21.7% MAXIMUM ALLOWABLE LOT COVERAGE: 35% 21.7% < 35%, THUS OK APR. 22 MD PLANNING APPROVED • No changes .can be madeto these plans without approval from the Planning Division of DCD Approved By: Date:: REVISIONS "ca nes shs” he rade to the scone r t >Rr ;„ °RR;tt�rr trapproval et �.7 e i i1u' ..bio N rk "qufr ,' as rimv r(I!'w'n si mitt I re.....fmrg3! tib: Q EXISTING DRIVEWAY 122.13' ±7'-10 1/4" O 20'-0" REQUIRED FRONT YARD SETBACK N +30'-0" PROP. L TO EXSITING EXISTING SANITARY SEWER 1 ±32'-11" 11 t v9 t-. cles Cily of Tukwila BUILDIUG DIVISION EXISTING STOOP AND STAIRS Oa 4x aA LINE OF EXISTING a0 FENCE a a BUILDING DEPARTMENT NOTES CONTINUED BUILDING DEPARTMENT NOTES WASHINGTON STATE ENERGY CODE NO ADDITIONAL HEATED AREA PROPOSED, REPLACEMENT WINDOWS AND DOORS IN EXITING HEATED BUILDING ENVELOPE SHALL CONFORM TO MINIMUM PRESCRIPTIVE REQUIREMENTS OF THE WSEC. STUD BAYS OPENED THROUGH THE COURSE OF CONSTRUCTION SHALL BE FILLED WITH NEW R-15 COMPRESSED BATT INSULATION. SCOPE OF WORK.: PROJECT OWNER: 30'-0" EXIST'G 5'-0" EXIST'G 5'-0" EXIST'G 10'-0" EXIST'G LANCE OYLER PROJECT ADDRESS: 13348 34TH AVE SOUTH TUKWILA, WA 98168 ASSESSOR'S NUMBER: # 359250-0480 LEGAL DESCRIPTION: INTERLAKEN ADDITION, BLOCK 10, LOT 15 ZONING: LOW DENSITY RESIDENTIAL REQUIRED SETBACKS: FRONT YARD 20'-O" REQ'D NORTH SIDE YARD 5'-0" REQ'D SOUTH SIDE YARD 5'-0" REQ'D REAR YARD 10'-0" REQ'D i. BUILDING DEPARTMENT NOTES CONTINUED BUILDING HEIGHT: EXIST'G, NO CHANGE. LOT AREA: 6,020 SF BUILDING FOOTPRINT: EXIST'G HOUSE: (25'-11")(32'-11") = 853.1 SQ.FT. EXISTING DECK: (12'-3")(10'-7 1/2") + (4'-6")(3'-6 1/2") = 146.1 SQ.FT. EXISTING STOOP AND STAIR: 3'-8 1/4"x7'-10 1/4" = 28.8 SQ.FT. EXISTING SHOP: (12'-0“)(20'-0") = 240.0 SQ.FT. SHOP ADDITION: (2)(7'-11")(3'-0") = 41.5 SQ.FT. TOTAL: 853.1 + 146.1 + 28.8 + 240.0 + 41.5 =1,309.5 SQ.FT. LOT COVERAGE: 1,309.5/6,020 = 21.7% MAXIMUM ALLOWABLE LOT COVERAGE: 35% 21.7% < 35%, THUS OK APR. 22 MD PLANNING APPROVED • No changes .can be madeto these plans without approval from the Planning Division of DCD Approved By: Date:: REVISIONS "ca nes shs” he rade to the scone r t >Rr ;„ °RR;tt�rr trapproval et �.7 e i i1u' ..bio N rk "qufr ,' as rimv r(I!'w'n si mitt I re.....fmrg3! tib: Q EXISTING DRIVEWAY 122.13' ±7'-10 1/4" O 20'-0" REQUIRED FRONT YARD SETBACK N +30'-0" PROP. L TO EXSITING EXISTING SANITARY SEWER 1 ±32'-11" 11 t v9 t-. cles Cily of Tukwila BUILDIUG DIVISION EXISTING STOOP AND STAIRS Oa 4x aA LINE OF EXISTING a0 FENCE a a -PILE COPY Permit No., ,a -.42.L.22 Plan review approval is subject to errors and iss•e. Approval of construction documents does not authorize thojz the violation of any adopted code or ordinance. Receipt of approved Fi Id Cop and conditions is acknowledged: 6y. Date: City of Tukwila BUILDING DIVISION 10'-0" PROP. LINE TO EXISTING SHOP ±20'-0" EXISTING ♦z APR 222Qia REVIEWED FOR CODE COMPLIANCE APPROVED IJIJL 17 2017 141— ity of Tukwila BUILDING DIVISION 92'-2 1/4" PROPERTY LINE TO EXISTING SHOP NEW, TYP. vAXISTING HOUSE +moi 00 i T SLOPE [}__PROPOSED SKYLIGHTS r. ±10'-7 1/2" EXISTING - DECK PROPOSED SOLAR PANELS UNDER SEPARATE PERMIT / a' 6" �-jf, NEW STANDING SEAM SLOPE METAL ROOFING, AT EXISTING ROOF. ±32'-9 3/4" cn cV -H PROPOSED SHOP ADDITION (2) EXISTING SLOPE NEW STANDING SEAM METAL ROOFING, AT EXISTING ROOF, TYP. EXISMTG-SLOPE 7'-11 111 y 1111 LOCATIONS 7'-11 111 EXISTING PEAR TREE N 122.70' N SITE PLAN 1/8" I��„o 2' =1'-0” 0 4' - 8' 16' PROPOSED O H OOA 1-4 EXISTING APPLE p-' O Ox TREE / \\ / \ ±59'-8 3/4" PROP LINE TO I EXISTING / - 10'-0" RE • UIRED REARYARD SETBACK SKYLIGHT (13... RECtIVED -CITY OF TUKWILA iloJUL 11 2017 1 PERMIT (CENTER 1 o s Wig, Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 W . � � W y cg) -4tt con v4 -,L4 M W M •�"�, *211 chn >21 O H 10729 REGISTERED ARCHI CT LANCE 0 LER STATE OF WASHINGTON REVISIONS DATE May 31, 2017 A1.O BUILDING DEPARTMENT NOTES CONTINUED WASHINGTON STATE ENERGY CODE NO ADDITIONAL HEATED AREA PROPOSED, REPLACEMENT WINDOWS AND DOORS IN EXITING HEATED BUILDING ENVELOPE SHALL CONFORM TO MINIMUM PRESCRIPTIVE REQUIREMENTS OF THE WSEC. STUD BAYS OPENED THROUGH THE COURSE OF CONSTRUCTION SHALL BE FILLED WITH NEW R-15 COMPRESSED BATT INSULATION. SCOPE OF WORK.: HOUSE: NEW ROOF OVERHANGS, SHEATHING AND ROOFING. REPLACEMENT EXTERIOR WINDOWS AND DOORS. NEW SKYLIGHTS. REMODEL EXISTING KITCHEN, BATHROOM, CLOSETS AND LAUNDRY FACILI'T'IES. REVISIONS TO INCLUDE NO ADDITIONAL HOUSE BUILDING AREA. NEW SOLAR PANELS UNDER SEPARATE PERMIT. NEW MINI -SPLIT HEATING SYSTEM UNDER SEPARATE PERMIT. SHOP: NEW SHOP ENTRY DOOR, NEW UNHEATED SHOP STORAGE ROOM ADDITIONS. -PILE COPY Permit No., ,a -.42.L.22 Plan review approval is subject to errors and iss•e. Approval of construction documents does not authorize thojz the violation of any adopted code or ordinance. Receipt of approved Fi Id Cop and conditions is acknowledged: 6y. Date: City of Tukwila BUILDING DIVISION 10'-0" PROP. LINE TO EXISTING SHOP ±20'-0" EXISTING ♦z APR 222Qia REVIEWED FOR CODE COMPLIANCE APPROVED IJIJL 17 2017 141— ity of Tukwila BUILDING DIVISION 92'-2 1/4" PROPERTY LINE TO EXISTING SHOP NEW, TYP. vAXISTING HOUSE +moi 00 i T SLOPE [}__PROPOSED SKYLIGHTS r. ±10'-7 1/2" EXISTING - DECK PROPOSED SOLAR PANELS UNDER SEPARATE PERMIT / a' 6" �-jf, NEW STANDING SEAM SLOPE METAL ROOFING, AT EXISTING ROOF. ±32'-9 3/4" cn cV -H PROPOSED SHOP ADDITION (2) EXISTING SLOPE NEW STANDING SEAM METAL ROOFING, AT EXISTING ROOF, TYP. EXISMTG-SLOPE 7'-11 111 y 1111 LOCATIONS 7'-11 111 EXISTING PEAR TREE N 122.70' N SITE PLAN 1/8" I��„o 2' =1'-0” 0 4' - 8' 16' PROPOSED O H OOA 1-4 EXISTING APPLE p-' O Ox TREE / \\ / \ ±59'-8 3/4" PROP LINE TO I EXISTING / - 10'-0" RE • UIRED REARYARD SETBACK SKYLIGHT (13... RECtIVED -CITY OF TUKWILA iloJUL 11 2017 1 PERMIT (CENTER 1 o s Wig, Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 W . � � W y cg) -4tt con v4 -,L4 M W M •�"�, *211 chn >21 O H 10729 REGISTERED ARCHI CT LANCE 0 LER STATE OF WASHINGTON REVISIONS DATE May 31, 2017 A1.O ±32'-11 1/2" EXISTING ±1'-3" EX. 1 ±2'-0 1/4" EX.( -±2'-3 1/2" EX ±4'-8 1/4" ; 2'-9 1/2' � �2'-9 1/2' ±3'-0" — EXISTING 1 XIST' & yEXIST'c 'EXIST' 10'-11 1/2" NEW 100 CFM VENT HOOD ±25'-11 1/4" EXISTING KITCHEN/DINING T LIVING ROOM � 2'-0"2'-0 1/4"2'-0" 6 1/2" 5 3/ " L -1 1/4" .L -/ 6'-7 1/2" � 2'40" 1,,±2'-3"), R.O. ±10'-10" EXISTING NEW 70 CFM EXHAUST FAN 6 3/4' 4'-10" R.O. 8 1/21" M. BEDROOM EGRESS NEW 70 CFM EXHAUST FAN ±5'-7 1/4" -3 1/•" ±5'-4 3/4" EXISTING ' XIST' 6 EXISTING SKYLIGHT SCHEDULE MFR: MILGARD NFRC TESTED U -VALUE (INSULATED, AIR-FILLED) = 0.50 (MAXIMUM) MARK MARK FRAME SIZE TYPE MFR'S CAT# MATERIAL GLASS REMARKS 0 2'-0" x 4'-0" FIXED 750 -SERIES BRONZE ANODIZED ALUMINUM TEMPERED, INSULATED, AIR-FILLED LOWER PANE TO BE LAMINATED. 0 2'-0" x 4'-0" FIXED 750 -SERIES BRONZE ANODIZED ALUMINUM 'TEMPERED, INSULATED, AIR-FILLED LOWER PANE TO BE LAMINATED. YES TEMPERED NOTE: SKYLIGHTS SHALL BE BUILT ON 4" MIN. CURB. © ' I "±4'-41/2" �2-9/2 x 3-(c CLAD FIXED AWNING ---- ±32'-11 1/2" EXISTING ±1'-3" EX. 1 ±2'-0 1/4" EX.( -±2'-3 1/2" EX ±4'-8 1/4" ; 2'-9 1/2' � �2'-9 1/2' ±3'-0" — EXISTING 1 XIST' & yEXIST'c 'EXIST' 10'-11 1/2" NEW 100 CFM VENT HOOD ±25'-11 1/4" EXISTING KITCHEN/DINING T LIVING ROOM � 2'-0"2'-0 1/4"2'-0" 6 1/2" 5 3/ " L -1 1/4" .L -/ 6'-7 1/2" � 2'40" 1,,±2'-3"), R.O. ±10'-10" EXISTING NEW 70 CFM EXHAUST FAN 6 3/4' 4'-10" R.O. 8 1/21" M. BEDROOM EGRESS NEW 70 CFM EXHAUST FAN ±5'-7 1/4" -3 1/•" ±5'-4 3/4" EXISTING ' XIST' 6 EXISTING WINDOW SCHEDULE WOOD CLAD WINDOW MFR: MILGARD NFRC TESTED U -VALUE FOR WINDOWS=: 0.30 MAX. FIBERGLASS WINDOW MFR: MILGARD MARK MARK FRAME SIZE TYPE MFR'S CAT# INTERIOR LINER (Verify wall thickness before ordering.) SCREEN GLASS REMARKS ® ±2'-6" x ±3'-2" DOUBLE HUNG ---- FOR 2x4 WALL YES ---- ---- ® 13'-2" x ±3'-2" o CLAD AWNING ---- FOR 2x4 WALL YES TEMPERED ---- © ' I "±4'-41/2" �2-9/2 x 3-(c CLAD FIXED AWNING ---- FOR 2x4 WALL YES TEMPERED ---- 0 ±2'-9 %2" x ±4'-41/2" CLAD AWNING ---- FOR 2x4 WALL YES TEMPERED ---- 0 ±2'-91/2" x ±4'-4 %2" CLAD CASEMENT ---- FOR 2x4 WALL YES ---- ---- 0 ±2'-31/2" x ±4'-41/2" CLAD CASEMENT ---- FOR 2x4 WALL YES ---- ±2'-0" x 6'-8" x 1-3/8" 0 ±2'-31/2" x ±4'-41/2" o CLAD AWNING ---- FOR 2x4 WALL YES ---- ---- 0 ±2'-3 3/4" x ±2'-8 %4" o FIBERGLASS AWNING CUSTOM FOR 2x4 WALL YES TEMPERED ---- OK ±2'-31/2" x ±4'-41/2" o CLAD AWNING ---- FOR 2x4 WALL YES ---- ---- 0 ±2'-31/2" x ±4'-41/2" CLAD CASEMENT ---- FOR 2x4 WALL YES ---- ---- ±32'-11 1/2" EXISTING ±1'-3" EX. 1 ±2'-0 1/4" EX.( -±2'-3 1/2" EX ±4'-8 1/4" ; 2'-9 1/2' � �2'-9 1/2' ±3'-0" — EXISTING 1 XIST' & yEXIST'c 'EXIST' 10'-11 1/2" NEW 100 CFM VENT HOOD ±25'-11 1/4" EXISTING KITCHEN/DINING T LIVING ROOM � 2'-0"2'-0 1/4"2'-0" 6 1/2" 5 3/ " L -1 1/4" .L -/ 6'-7 1/2" � 2'40" 1,,±2'-3"), R.O. ±10'-10" EXISTING NEW 70 CFM EXHAUST FAN 6 3/4' 4'-10" R.O. 8 1/21" M. BEDROOM EGRESS NEW 70 CFM EXHAUST FAN ±5'-7 1/4" -3 1/•" ±5'-4 3/4" EXISTING ' XIST' 6 EXISTING ±2'-3 1/2" EX. 5'-3 1/4" ±13'-3 1/2" EXISTING 2'9 1/4" ±5'-6 1/2" ±11'-4 1/4" EXISTING EXIST' EXISTING MAIN LEVEL PLAN 1/4" =1'-0" 0 1' 2' 4' DOOR SCHEDULE GLAZED CLAD WOOD DOOR MFR: MILGARD NFRC TESTED U -VALUE FOR INSULATED GLAZED DOORS: =0.30 MAX MARK LOCATION DOOR SIZE TYPE MFR'S CAT# INTERIOR FINISH EXTERIOR FINISH LATCH/CATCH REMARKS 0 KITCHEN ±2'-8" x6'-10" R.O. INSWING FRENCH DOOR STAIN CLAD PATIO LOCK AND DEADBOLT 0 PANTRY 2'-6" x6' -8"x 1 3/8" SOLID CORE WOOD DOOR STAIN PASSAGE LATCH 0 CLOSET (2) 2'-4" x 6'-8" x 1-3/8" SOLID CORE WOOD DOORS, PAIR STAIN DUMMY KNOB 0 LAUNDRY 2'-8" x 6'-8" x 1-3/8" VENTED SOLID CORE WOOD DOOR . STAIN PASSAGE LATCH 0 BATH ±2'-4" x ±6'-8" x 1-3/8" SOLID CORE WOOD DOOR STAIN PRIVACY LOCK 07 LINEN ±2'-0" x 6'-8" x 1-3/8" SOLID CORE WOOD DOOR STAIN PASSAGE LATCH 0 CLOSET (2) 2'-4" x 6'-8" x 1-3/8" SOLID CORE WOOD DOORS, PAIR STAIN DUMMY KNOB ±2'-3 1/2" EX. 5'-3 1/4" ±13'-3 1/2" EXISTING 2'9 1/4" ±5'-6 1/2" ±11'-4 1/4" EXISTING EXIST' EXISTING MAIN LEVEL PLAN 1/4" =1'-0" 0 1' 2' 4' APR 222I3 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 17 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JUL 11 2017 PERMIT CENTER W6L Architecture uc 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 ,10720 1 � , DANCE onER STATE OF WASHINGTON REGISTERED AR ITECT REVISIONS .•rZ DATE May 31, 2017 A2.0 KEY: NEW SMOKE DETECTOR, MAY BE BATTERY OPERATED:• PROPOSED NEW WALLS: EXSITING WALLS TO BE REMOVED: APR 222I3 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 17 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JUL 11 2017 PERMIT CENTER W6L Architecture uc 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 ,10720 1 � , DANCE onER STATE OF WASHINGTON REGISTERED AR ITECT REVISIONS .•rZ DATE May 31, 2017 A2.0 EXISTING HARDI BOARD SIDING - NEW METAL STTDTNG EAST ELEVATION 1/4" =1'-0" EXISTING 20'-0" EXISTING EXISTING EXISTING W STANfING EAMMEIALROOFING IYIETAL SIDING SOUTH ELEVATION 1/4" = 1'-0" -NEW METAL SIDING 'i 11 TYPICAL LOW ROOF NEW METAL ROOFING NEW 20# ROOFING FELT NEW 1/2" PLYWOOD SHEATHING EXISTING SITE BUILT TRUSSES EXISTING 2x4 RAFTERS NEW 2x4 CEILING JOISTS @ 24" O.C. NEW 1/2" PLYWOOD FINISH CEILING TYPICAL NEW EXTERIOR WALL 3 `--(2)2x6 HEADER (2)2x6 NEW METAL SIDING (2) LAYERS 60 MINUTE BUILDING PAPER NEW 1/2" PLYWOOD SHEATHING NEW 2x4 STUDS @ 16" O.C. NEW W PLYWOOD SHEATHING TYPICAL NEW SLAB -ON -GRADE HEADER TOOLSHED a' I-1 I i -17 -11 -I171 -1 I II I- 1 -:4..,f�..�x1` 10111111-,7,1 _�.=1 '' I 1 11111 ' 1 11=1 I-II11--I- _� -4N--I {� -I-I i 11 I 111=111=1111=111 ��� ���-III=LII;,II 1-111- > �II,;,Iil-I1=11J= >< TYPICAL EXISTING SHED ROOF NEW METAL ROOFING NEW OR EXISTING 20# ROOFING FELT EXISTING 1/2" PLYWOOD SHEATHING EXISTING 2x8 RAFTER&@_L6" O.0 EXISTING 1/2" G.W.B. TYPICAL EXISTING EXTERIOR WALL EXISTING SIDING PER ELEVATION EXISTING 15# BUILDING PAPER EXISTING 1/2" PLYWOOD SHEATHING EXISTING 2x4 STUDS @ 16" O.C. EXISTING 1/2" G.W.B. III= EXISTING 4" CONCRETE SLAB ON GRADE WITH WWF EXISTING 6x6 W 1.4xW 1.4 EXISTING MOISTOP VAPOR BARRIER OR EQUAL EXISTING 4" FREE DRAINING GRAVEL FILL EXISTING COMPACTED EARTH mo ---EXISTING FASCIA 1 EXISTING FASCIA APR 2 2 2.0T NEW 4" SLAB ON GRADE W/ WWF 4x4 W1.4xW1.4-� L L J J NEW 4" SLAB ON GRADE W/ WWF 4x4 W 1.4xW 1.4 12'-0" EXISTING NEW 4" SLAB ON GRADE W/ WWF 4x4 W1.4xW1.4 (f \ FOUNDATION PLAN 1/4" =1'-0" 0 1' 2' 4' 001&16,R gg.04,4,4,4,04.4A01401.11(030,444,1 WWI 00k6gotv,000/0.10 2x4 STUD, TYP EXISTING (2)2x6 HDR ABOVE, NEW (2)2x6 HEADER BELOW N t EXISTING HARDI BOARD SIDING - NEW METAL �TTlT�T(T r WEST ELEVATION 1/4" = 1'-0" O U XIST I G (2)2x6 HDR FCR FUTURE GARAGE DOC)R EXISTING (2)2x6 HDR ABOVE BLOW EXISTING (2)2x6 HDR ABOVE, NEW (2)2x6 HEADER BELOW EXISTING 2x4 ROOF RAFTERS @ 16" O.C. EXISTING TRUSS PER DETAIL (4) LOCATIONS, TYP. III —I I I—ITP -Ill,-III-'' (A) SECTION 'A' 1/4" =1'-0" TYPICAL EXISTING SLAB -ON -GRADE EXISTING 4" CONCRETE SLAB ON GRADE WITH WWF EXISTING 6x6 W 1.4xW 1.4 EXISTING MOISTOP VAPOR BARRIER OR EQUAL EXISTING 4"FREE DRAINING GRAVEL FILL EXISTING COMPACTED EARTH --NEW STANDING SEAM METAL METAL ROOFING L7 8'-0" EXISTING PLATE EXISTING HARDI BOARD SIDING -7 L� 2x8 FASCIA BOARD -LINE OF CARPORT BEYOND APR2 2 28 ±EX_STING 2x6 LEDGER W/ (2) 16d NAILS @ 16" O.C. AT STUD LOCATIONS, TYP. EXISTING 2x4 ROOF RAFTERS @ 16" O.C. ROOF FRAMING PLAN 1'-0" EXISTING EAVE, TYP E NORTH ELEVATION 1/4" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 17 2017 City of Tukwila BUILDING DIVISION 20'-0" RECEIVED CITY OF Tiii(WiLA JUL 112011 PERMIT CENTER 4'-7" 15'-5" • TOOLSHED UNHEATED (EXISTING) LINE OF EXISTING WALL TO BE REMOVED. IT ±7 1/2" i L_ n ' ±5'-61%2" IILI ±7 1/2" ±5'-6 1/2" -STORAGE UNHEATED (NEW) L STOOP (NEW) 0 I Fn 3 3/4" ±2 1/4" 6'-11" 5'-9 1/2" RMON 3 3/4" 6'-11" Li J —±2 1/4" WoL Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 1072 REGISTERED AR HITECT SHOP DOOR SCHEDULE MARK LOCATION DOOR SIZE TYPE MFR'S CAT# INTERIOR FINISH EXTERIOR FINISH LATCH/CATCH REMARKS 1U SHOP (2) 2'-6" x6' -8"x 1 3/4" * OUTSWING DOORS, PAIR PAINT PAINT PATIO LOCK AND DEADBOLT ---- EXISTING HARDI BOARD SIDING - NEW METAL STTDTNG EAST ELEVATION 1/4" =1'-0" EXISTING 20'-0" EXISTING EXISTING EXISTING W STANfING EAMMEIALROOFING IYIETAL SIDING SOUTH ELEVATION 1/4" = 1'-0" -NEW METAL SIDING 'i 11 TYPICAL LOW ROOF NEW METAL ROOFING NEW 20# ROOFING FELT NEW 1/2" PLYWOOD SHEATHING EXISTING SITE BUILT TRUSSES EXISTING 2x4 RAFTERS NEW 2x4 CEILING JOISTS @ 24" O.C. NEW 1/2" PLYWOOD FINISH CEILING TYPICAL NEW EXTERIOR WALL 3 `--(2)2x6 HEADER (2)2x6 NEW METAL SIDING (2) LAYERS 60 MINUTE BUILDING PAPER NEW 1/2" PLYWOOD SHEATHING NEW 2x4 STUDS @ 16" O.C. NEW W PLYWOOD SHEATHING TYPICAL NEW SLAB -ON -GRADE HEADER TOOLSHED a' I-1 I i -17 -11 -I171 -1 I II I- 1 -:4..,f�..�x1` 10111111-,7,1 _�.=1 '' I 1 11111 ' 1 11=1 I-II11--I- _� -4N--I {� -I-I i 11 I 111=111=1111=111 ��� ���-III=LII;,II 1-111- > �II,;,Iil-I1=11J= >< TYPICAL EXISTING SHED ROOF NEW METAL ROOFING NEW OR EXISTING 20# ROOFING FELT EXISTING 1/2" PLYWOOD SHEATHING EXISTING 2x8 RAFTER&@_L6" O.0 EXISTING 1/2" G.W.B. TYPICAL EXISTING EXTERIOR WALL EXISTING SIDING PER ELEVATION EXISTING 15# BUILDING PAPER EXISTING 1/2" PLYWOOD SHEATHING EXISTING 2x4 STUDS @ 16" O.C. EXISTING 1/2" G.W.B. III= EXISTING 4" CONCRETE SLAB ON GRADE WITH WWF EXISTING 6x6 W 1.4xW 1.4 EXISTING MOISTOP VAPOR BARRIER OR EQUAL EXISTING 4" FREE DRAINING GRAVEL FILL EXISTING COMPACTED EARTH mo ---EXISTING FASCIA 1 EXISTING FASCIA APR 2 2 2.0T NEW 4" SLAB ON GRADE W/ WWF 4x4 W1.4xW1.4-� L L J J NEW 4" SLAB ON GRADE W/ WWF 4x4 W 1.4xW 1.4 12'-0" EXISTING NEW 4" SLAB ON GRADE W/ WWF 4x4 W1.4xW1.4 (f \ FOUNDATION PLAN 1/4" =1'-0" 0 1' 2' 4' 001&16,R gg.04,4,4,4,04.4A01401.11(030,444,1 WWI 00k6gotv,000/0.10 2x4 STUD, TYP EXISTING (2)2x6 HDR ABOVE, NEW (2)2x6 HEADER BELOW N t EXISTING HARDI BOARD SIDING - NEW METAL �TTlT�T(T r WEST ELEVATION 1/4" = 1'-0" O U XIST I G (2)2x6 HDR FCR FUTURE GARAGE DOC)R EXISTING (2)2x6 HDR ABOVE BLOW EXISTING (2)2x6 HDR ABOVE, NEW (2)2x6 HEADER BELOW EXISTING 2x4 ROOF RAFTERS @ 16" O.C. EXISTING TRUSS PER DETAIL (4) LOCATIONS, TYP. III —I I I—ITP -Ill,-III-'' (A) SECTION 'A' 1/4" =1'-0" TYPICAL EXISTING SLAB -ON -GRADE EXISTING 4" CONCRETE SLAB ON GRADE WITH WWF EXISTING 6x6 W 1.4xW 1.4 EXISTING MOISTOP VAPOR BARRIER OR EQUAL EXISTING 4"FREE DRAINING GRAVEL FILL EXISTING COMPACTED EARTH --NEW STANDING SEAM METAL METAL ROOFING L7 8'-0" EXISTING PLATE EXISTING HARDI BOARD SIDING -7 L� 2x8 FASCIA BOARD -LINE OF CARPORT BEYOND APR2 2 28 ±EX_STING 2x6 LEDGER W/ (2) 16d NAILS @ 16" O.C. AT STUD LOCATIONS, TYP. EXISTING 2x4 ROOF RAFTERS @ 16" O.C. ROOF FRAMING PLAN 1'-0" EXISTING EAVE, TYP E NORTH ELEVATION 1/4" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 17 2017 City of Tukwila BUILDING DIVISION 20'-0" RECEIVED CITY OF Tiii(WiLA JUL 112011 PERMIT CENTER 4'-7" 15'-5" • TOOLSHED UNHEATED (EXISTING) LINE OF EXISTING WALL TO BE REMOVED. IT ±7 1/2" i L_ n ' ±5'-61%2" IILI ±7 1/2" ±5'-6 1/2" -STORAGE UNHEATED (NEW) L STOOP (NEW) 0 I Fn 3 3/4" ±2 1/4" 6'-11" 5'-9 1/2" RMON 3 3/4" 6'-11" Li J —±2 1/4" WoL Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 1072 REGISTERED AR HITECT LAN E OYLER STATE OF WASHINGTON REVISIONS SHOP ADDITION DATE May 31, 2017 A2.1 KEY/NOTES: NEW PROPOSED BUILDING AREA: PROPOSED NEW WALLS: EXISTING WALLS TO BE REMOVED: LAN E OYLER STATE OF WASHINGTON REVISIONS SHOP ADDITION DATE May 31, 2017 A2.1 E -J =7 EXISTING CONCRETE STEPS. Li LJ LJ Li u Li L LJ L., r EXISTING CMU FOUNDATION WALL AND FOOTING, TYPICAL EXISTING 6x8 DROPPED 111 BEAM L__J EXISTING 6x8 DROPPED -1 EXISTING 6x8 BEAM l_ _ J DROPPED BEAM NEW POINT LOAD FROM ABOVE, TYPICAL (4) LOCATIONS 1 1 LJ. EXISTING 6x8 DROPPED r EXISTING 6x8 DROPPED EXISTING 6x8 BEAM BEAM I_ _ J DROPPED BEAM EXISTING 6x8 POST AND CONCRETE FOOTING, TYPICAL L_ L L_ _J 0 0 00 N 1 C r EXISTING BEAM N J n r -t n n n EXISTING GAS METER APS 22.2 EXISTING P.T.2x6 DECK JOISTS @ 16" O.C. WITH EXISTING SPACED CEDAR DECKING U J N 0 EXISTING IDOUNDATION PLAN 1/4" =1'-0" 0 1' 2' 4' 8' EXISTING P.T.4x6 CONTINUOUS DROPPED BEAM, TYPICAL (4) LOCATIONS AM 22 EXIST'G HDR STRUCTURAL PLAN NOTES: 1. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING W/ A PANEL INDEX OF 24/0 2. ENTIRE ROOF DIAPHRAGM TO HAVE NEW PLYWOOD SHEATHING WITH 10d NAILS @ 6" O.C. MIN. AT PANEL EDGES AND 12" MIN. O.C. IN THE FIELD. 3. ALL BEAMS AND HEADERS SHALL (2) 2x8 MINIMUM UNLESS NOTED OTHERWISE. 4. ALL COLUMNS SHALL BE DOUBLE STUD MINIMUM W/ THE BEAM OR HEADER BEARING FULLY ON THE COLUMN. AM 22 EXIST'G HDR TYP. NEW 2x4 OUTLOOKS@ 24" O.C. TYPICAL. NEW GUTTER, TYPICAL. NEW DOWNSPOUT IN EXISTING LOCATION, TYPICAL N ROOF FRAMING PLAN 1/4" = l'-0" 0 1 2' 4' NEW 2x4 OUTLOOKS@ 24" O.C. TYPICAL. APR 2 2 26'3 INF REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JUL 11 2017 PERMIT CENTER WOL Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 10729', REGISTERED ARCHITECT LANCE OYLER STATE OF WASHINGTON REVISIONS DATE May 31, 2017 A3.0 STRUCTURAL PLAN NOTES: 1. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING W/ A PANEL INDEX OF 24/0 2. ENTIRE ROOF DIAPHRAGM TO HAVE NEW PLYWOOD SHEATHING WITH 10d NAILS @ 6" O.C. MIN. AT PANEL EDGES AND 12" MIN. O.C. IN THE FIELD. 3. ALL BEAMS AND HEADERS SHALL (2) 2x8 MINIMUM UNLESS NOTED OTHERWISE. 4. ALL COLUMNS SHALL BE DOUBLE STUD MINIMUM W/ THE BEAM OR HEADER BEARING FULLY ON THE COLUMN. TYP. NEW 2x4 OUTLOOKS@ 24" O.C. TYPICAL. NEW GUTTER, TYPICAL. NEW DOWNSPOUT IN EXISTING LOCATION, TYPICAL N ROOF FRAMING PLAN 1/4" = l'-0" 0 1 2' 4' NEW 2x4 OUTLOOKS@ 24" O.C. TYPICAL. APR 2 2 26'3 INF REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JUL 11 2017 PERMIT CENTER WOL Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 10729', REGISTERED ARCHITECT LANCE OYLER STATE OF WASHINGTON REVISIONS DATE May 31, 2017 A3.0 ±12 ±6 T.O. EXISTING RIDGE T.O. EXISTING PLATE 00 01 N N T.O. EXISTING N 0 00 TYPICAL EXISTING ROOF ASSEMBLY NEW STANDING SEAM METAL ROOFING NEW BUILDING PAPER NEW %" PLYWOOD SHEATHING EXISTING WOOD SHEATHING EXISTING 2x4 RAFTERS @ 24" O.C. EXISTING 2x5 CEILING JOISTS @ 24" O.C. NEW G.W.B. FINISH CEILING. ±6 ±12 NEW SKYLIGHT CONTINUOUS RIDGE BEAM, TYPICAL NEW 2x12 FURRING AND R-38 BATT INSULATION BEYOND, MAINTAIN 1" MIN ABOVE INSULATION FOR VENTILATION. EXISTING SLOPE NEW R-21 BATT INSULATION AT NEW SKYLIGHT WELL •.•.•.•.•.•.•.•.•.•.•.•.•.•.•.•.111.••••.••.•.•.•.•& T.O. EXISTING RIDGE ®- T.O. EXISTING PLATE 0`00 In rn W6L Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 TYPICAL EXISTING INTERIOR WALL ASSEMBLY NEW OR EXISTING G.W.B. EXISTING 2x4 STUDS AT 16" O.C. NEW OR EXISTING G.W.B. TYPICAL EXISTING WALL ASSEMBLY EXISTING LAP SIDING EXISTING BUILDING PAPER EX3STING-SHEATHING EXISTING 2x4 STUDS AT 16" O.C. NEW R-15 OR EXISTING BATT INSULATION NEW OR EXISTING G.W.B. TYPICAL EXISTING FLOOR ASSEMBLY REFINISHED EXISTING HARDWOOD FINISH FLOOR EXISTING SHEATHING EXISTING 2x8FLOOR JOISTS AT 16" O.C. EXISTING BATT INSULATION ±17'-2 3/4" EXISTING ±6 ±12 WEST ELEVATION 1/4" = 1'-0" SHEATHING T.O. EXISTING GRADE Apa 20i0 T.O. EXISTING RIDGE LINE OF EXISTING GABLE END VENT TO BE REMOVED, PATCH AND REPAIR OPENING AS REQUIRED, TYPICAL LINE OF EXISTING DOOR, PATCH AND REPAIR SIDING AS REQUIRED. EAST ELEVATION 1/4" = 1'-0" EXISTING FOUNDATION VENT, TYPICAL T.O. EXISTING PLATE 0 00 T.O. EXISTING SHEATHING T.O. EXISTING GRADE ±18'-1" EXISTING LIVING ROOM BEDROOM #1 0 00 CRAWLSPACE r 1 T.O. EXISTING SHEATHING SOLAR PANELS UNDER SEPARATE PERMIT. STANDING SEAM METAL ROOFING. K ) 114 -J SOUTH ELEVATION 1/4" = 1'-0" LINE OF EXISTING WINDOW, PATCH AND REPAIR SIDING AS REQUIRED. NEW STANDING SEAM METAL ROOFING. -7 EXISTING DECK AND RAIING 7-7 / \ J SOY G LAP SIDIN Ail A T.O. EXISTING RIDGE T.O. EXISTING PLATE EXISTING DECK AND RAZING T.O. EXISTING SHEATHING 00 T.O. EXISTING GRADE APR 2 2 26 NORTH ELEVATION 1/4" =1'-0" T.O. EXISTING RIDGE rn T.O. EXISTING PLATE T.O. EXISTING SHEATHING 0 00 ±17'-1 1/8" EXISTING EXISTING STEPS AND RAILING, RAILING NOT SHOWN FOR CLARITY. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2017 City of Tukwila BUILDING DIVISION T.O. EXISTING GRADE RECEIVE CITY OF l U KWILA JUL 112017 PERMIT CENTER ;11T4 00 19 4 4 4° CA 14 M 04 ,� M ›ffi 10729 REGISTERED AR ITECT LAN OYLER STATE OF WASHINGTON REVISIONS DATE May 31, 2017 4.O NEW STANDING SEAM METAL ROOFING. NEW 20# ROOFING FELT. NEW /2" PLYWOOD SHEATHING WITH 10d NAILS @ 6" O.C. AT PANEL EDGES, 12" O.C. IN FIELD. NEW BLOCKING W/ (3) 1 7"2"x3"NOTCHES FOR VENTILATION NEW 3/4" PLYWOOD SHEATHING TO MATCH EXISTING AT NEW EAVE . NEW CONTINUOUS METAL DRIP EDGE . NEW CONTINUOUS METAL GUTTER NEW 2x FASCIA TO MATCH EXISTING. NEW 1 %2" CONTINUOUS SCREENED SOFFIT VENT. NEW 2x4 SOFFIT FRAMING. NEW 2x4 RAFTERS SISTERED TO EXISTING RAFTERS @ 24" O.C. NEW STANDING SEAM METAL ROOFING. NEW 20# ROOFING FELT. NEW 32" PLYWOOD SHEATHING WITH 10d NAILS @ 6" O.C. AT PANEL EDGES, 12" O.C. IN FIELD. NEW 2x4 OUTLOOKS @ 24" O.C. NEW CONTINUOUS METAL DRIP EDGE . NEW %4" PLYWOOD SHEATHING TO MATCH EXISTING AT NEW EAVE . NEW 2x FASCIA TO MATCH EXISTING. NEW 1 %2" CONTINUOUS SCREENED SOFFIT VENT. NEW BLOCKING W/ (4) 1 03 HOLES PER OUTLOOK FOR VENTILATION NEW 2x4 SUPPORT AT NEW OUTLOOKS, NAIL TO EXISTING FRAMING W/ (2) 16d AT EACH MEMBER. I It 2t_0tt 111 • , g r 4CC 111 EXISTING WOOD SHEATHING EXISTING 2x4 RAFTERS @ 24" O.C. EXISTING INSULATION, MAINTAIN 1" CLEAR BELOW SHEATHING FOR VENTILATION EXISTING 2x6 CEILING JOISTS @ 24" O.C. NEW OR EXISTING G.W.B. EXISTING 2x4 STUDS @ 16" O.C. EXISTING INSULATION EXISTING WOOD SHEATHING EXISTING BUILDING PAPER EXISTING SIDING EXISTING WOOD SHEATHING NEW 2x4 RAFTER @ NEW OUTLOOKS, NAIL TO EXISTING W/ (2) 16d @ 12" O.C. EXISTING 2x4 RAFTERS @ 24" O.C. EXISTING INSULATION, MAINTAIN 1" CLEAR BELOW SHEATHING FOR VENTILATION EXISTING 2x6 CEILING JOISTS @ 24" O.C. NEW OR EXISTING G.W.B. NEW OR EXISTING G.W.B. EXISTING 2x4 STUDS @ 16" O.C. EXISTING INSULATION EXISTING WOOD SHEATHING EXISTING BUILDING PAPER EXISTING SIDING (-2- NEW RAKE END NEW METAL FLASHING, LAP OVER NEW ROOFING BELOW. NEW STANDING SEAM METAL ROOFING. NEW 20# ROOFING FELT. NEW %2" PLYWOOD SHEATHING, NAIL AT 6" O.C. WITH 10d NAILS AT PANEL EDGES, 12" O.C. IN FIELD. NEW 1x4 FURRING STRIPS. NEW CONTINUOUS METAL DRIP EDGE. EXISTING ALU1VIENUM WINDOW. NEW CONTINUOUS SCREENED SOFFIT VENT. NEW WOOD SOFFIT. NEW 2x4 CEILING JOISTS. EXISTING PEEL AND STICK FLASHING MEMBRANE, LAP OVER NEW FLASHING BELOW. EXISTING WALL EXISTING 2x4 ROOF RAFTERS EXISTING FASCIA EXISTING CANTILEVERED TRUSSES PER PLAN.. NEW PLYWOOD FINISH. NEW (2) 2x6 HEADER PER PLAN. NEW WALL ASSEMBLY PER SECTION. APR 2. r 2010 NEW 6x6 WWF NEW /8" ANCHOR BOLTS @ 24" O.C. NEW (1) #4 CONTINUOUS TOP NEW #4x1@18"O.C. • APR 2 22 C EXISTING SLAB AND FOUNDATION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2011 Cilyof Tukwila BUILDING DIVISION NEW #4 DOWELS INTO _ _ EXISTING FOUNDATION @ 18" _ O.C., 6" MIN EMBED. NEW (2) #4 CONTINUOUS - BOTTOM iii iii iii iii iii 3 SHOP ADDITION SECTION 7.0 1 1/2" = 1'-0" t ECEP1.7.0 CITY OF TUKWILA JUL 11 2011 PERMIT CENTER WoL Architecture LLC 13348 34th Ave S Tukwila, WA 98169 T: (206) 714-7927 cat) 00 vi �► C31 /24:21 „Oral CA 4 M 4:4 00 III .11" M M..� M O 10729 LANC OYLER STATE OF WASHINGTON REVISIONS DO a H w DATE May 31, 2017 A7.0