Loading...
HomeMy WebLinkAboutPermit D17-0192 - YAMATO TRANSPORT - STORAGE RACKSYAMATO TRANSPORT 18271 ANDOVER PARK W D17-0192 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049104 18271 ANDOVER PARK W. Project Name: YAMATO TRANSPORT Permit Number: Issue Date: Permit Expires On: D17-0192 8/28/2017 2/24/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: LIT INDUSTRIAL LTD PTNSHP 1717 MCKINNEY AVE #1900 , DALLAS, WA, 75202 CHRIS LING Phone: (206) 394-3327 9800 40TH AVE S , SEATTLE, WA, 98118 ENGINEERED PRODUCTS, A PAPE CO Phone: (206) 394-3300 9800 40TH AVE S , SEATTLE, WA, 98188 ENGINPC931C0 Expiration Date: 2/20/2019 Lender: Name: YAMATO TRANSPORT Address: 18271 ANDOVER PARK W , TUKWILA, WA, 98188 DESCRIPTION OF WORK: INSTALLATION OF ADDITIONAL SELECTIVE PALLET RACK AND CANTILEVER RACK Project Valuation: $22,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $935.97 Occupancy per IBC: Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-468: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Lit IL Permit Center Authorized Signature: Dag" / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit doe of presume to give authority to violate or cancel the provisions of any other state or local laws r-:ulati . structio or the performance of work. I am authorized to sign and obtain this development • -rmit : n, . • e to t • nditio s attached to this permit. Signature: Print Name: ( e-75 �_ e Date: . P �f 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 0 Q 7: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 8: Maintain fire extinguisher coverage throughout. 10: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 11: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 12: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 13: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 14: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 15: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 111-01010, Project No Date Application Accepted: 1 1 r/ 1 Date Application Expires: 1 I% 146 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 411 King Co Assessor's Tax No.: Site Address: 18721 -ANDOVER PARK W Suite Number: Floor: New Tenant: ❑ Yes ®..No Tenant Name: Yamato Transport PROPERTY OWNER Name: Chris Ling Name: Clarion Partners Address: 9800 40th AVE S Address: 1717 McKinney AVE #1900 City: Seattle State: WA City: Dallas State: TX Zip: 75202 CONTACT PERSON — person receiving all project communication Name: Chris Ling Address: 9800 40th AVE S Address: 9800 40th AVE S Phone: (206) 394-3300 Fax: (206) 575-6688 City: Seattle State: WA Zip: 98118 Phone: (206) 394-3327 Fax: (206) 575-6688 Email: chrisl@epofwa.com GENERAL CONTRACTOR INFORMATION Company Name: ENGINEERED PRODUCTS Address: 9800 40th AVE S City: Seattle State: WA Zip: 98118 Phone: (206) 394-3300 Fax: (206) 575-6688 Contr Reg No.: ENGINPC931CO Exp Date: 02/20/2019 Tukwila Business License No.: BUS -010070 H:\Applications'Forms-Applications On Line \20I I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: Structural Concepts Engineering Engineer Name: Ali Abolhassani Company Name: City: La Verne State: CA Zip: 91750 Phone: (909) 596-1351 Fax: (909) 596-7186 Architect Name: City:..- ,� I h State:otec Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Structural Concepts Engineering Engineer Name: Ali Abolhassani Address: 1815 Wright AVE City: La Verne State: CA Zip: 91750 Phone: (909) 596-1351 Fax: (909) 596-7186 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: VArAiTryT '' Address: i.'7), i i L' h W f�r NAL City:..- ,� I h State:otec p Zip: igi r<! Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 22,000 Describe the scope of work (please provide detailed information): Installation of additional Selective Pallet Rack and Cantilever Rack Will there be new rack storage? V Yes ❑ .. No Existing Building Valuation: $ If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: VI Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplications\Forms-Applications On Line \201 I Applications\permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 35,000 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: VI Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplications\Forms-Applications On Line \201 I Applications\permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #I25 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View 0 .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton 0 .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards 0 .. Geotechnical Report ❑ .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 .. Grease Interceptor 0 ...Cap or Remove Utilities 0 .. Curb Cut 0 .. Channelization 0 ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation 0 ...Traffic Control 0 .. Looped Fire Line 0 .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation Domestic Water 0 ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. 5,WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private ❑ ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑...Water ❑...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O HO : " ,ED AGENT: Signature. Date: E° 763 /,,%i Print Name: aI't-S Day Telephone: .2.0t r Mailing Address: 9 qO 5 �r.lik 1 -at H:\ApplicationsWorms-Applications On Line \2011 ApplicationsU'ermit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT •PermitTRAK �. ." QUANTITY I PAID : $935.97 D17-0192 Address: 18271 ANDOVER PARK W Apn: 3523049104 $935.97 Credit Card Fee $27.26 Credit Card Fee R000.369.908.00.00 0.00 $27.26 DEVELOPMENT $882.12 PERMIT FEE R000.322.100.00.00 0.00 $531.89 PLAN CHECK FEE R000.345.830.00.00 0.00 $345.73 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $26.59 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11904 R000.322.900.04.00 0.00 $26.59 $935.97 Date Paid: Thursday, July 13, 2017 Paid By: CHRISTOPHER LING Pay Method: CREDIT CARD 02052B Printed: Thursday, July 13, 2017 12:02 PM 1 of 1 CRSYSTEMS INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. Va. CITY OF TUKWILA BUILDING DIVISION bid-U��iZ 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projec : '//VVVVlZl i tAf ? f7 Type of Inspection: Rci1LD1 &- AA/ L Address: Z-7/ AAThritide P t ,LA Date Called: Special Instructions: Date Wanted: G" / i7 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 4b&11 Date:/ i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit bi7-012 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: i/. , --ra 1SIALPozr Type of Inspectio : s) -M f J/ i' CO,K- Address: /6271 Aiv Date Called: Special Instructions: Date Want -)17 a.m. m• Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: nspector: Date: REINSPECT ON FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1)n—or-it? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:1 /..----- ,if // r/ Type of Inspection: `- iC. Address: ` Suite #: /,,2 7/ APIA' ` Contact Person: Special Instructions: .'_ ,,7 -7 ,i/J e -,-, 71...„4/.19.1" Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: /f. r -/, , ;ert-c4s --- 1//15S Occupancy Type: .'_ ,,7 -7 ,i/J e -,-, 71...„4/.19.1" �o .47,,,, 1, ,4",4-:-? n e�.. a 0 11s d�,�ikilfiv,..� ...."_.._", JY 4f .'41::>P111)44. �i��/1� , . l c„ -,a iA t 477)C /4-0,,,, 4 e ' / - -- P--` r / / Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /� Date: .aNi 2 Hrs.: 1. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Structural Concepts Engineering Project Name : YAMAMOTO Project Number : R-070617.-ItL Date : 07/10/17 1815 Wright Ave La Verne, Ca. 91750 Tel: 909-596-1951 Fax 909-596-7186 'REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 7 2017 City of Tukwila BUILDING DIVISION Street Address: 18721 ANDOVER PARK W City/State : TUKWILA, WA 98188 RECEIVED CITY OF TUKWILA JUL 1 3 2017 PERMIT CENTER Scope of Work : STORAGE RACK/ CANTILEVER JUL 1 1 207 Sttural r1Joncepts Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads 5 to 6 Column 7 Beam and Connector 8 to 9 Bracing 10 Anchors 11 •Base Plate 12 Slab on Grade 13 Other Configurations 14 to ZS YAMATO-TYPE I SELECTIVE RACK Page 2 of 2,1— 7/10/2017 Strturai oncepts Engineering By: BOB S. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 Project: YAMATO Project #: R-070617-11Iv Design Data 1) The analyses herein conforms to the requirements of the: 2015 IBC Section 2209 2016 CBC Section 2209A ANSI MH 16.1-2012 Specifications for the Design of Industrial Steel Storage Racks '2012 RMI Rack Design Manual" ASCE 7-10, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy=55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The existing slab on grade is 5" thick with minimum 2500 psi compressive strength. Allowable Soil bearing capacity is 750 psf. The design of the existing slab is by others. 6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level load criteria Definition of Components Frame Height Beam r Product 1 Beam Spacing Beam Length Front View: Down Aisle (Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors Panel Height Frame Depth Section A. Cross Aisle (Transverse) Frame Horizontal Brace Diagonal Brace YAMATO-TYPE I SELECTIVE RACK Page 3 of 7/10/2017 Str turaI kooncepts Engineering 1815 Wright Ave La Verne. CA 9175QTe1: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Configuration & Summary: TYPE 1 SELECTIVE RACK 192" 58" 60" 72" J 1- 96" 192" 48" 48" 48" 36" </> 44" =T 44" 4 **RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 128 /b AXIAL LL= 3,750 /b SEISMIC AXIAL Ps=+/- 4,938 /b BASE MOMENT= 8,000 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.427, Fa=1 3 44 in 192.0 in 4 96 in Beam Component Description STRESS Column Fy=55 ksi Hannibal IF3014-3x3x14ga P=3878 Ib, M=24292 in -Ib 0.99 -OK Column & Backer None None None N/A Beam Fy=55 ksi HMH 33160/3.375" Face x 0.06" thk Lu=96 in Capacity: 3672 Ib/pr 0.68-0K Beam Connector Fy=55 ksi Lvl 1: 3 pin OK Mconn=8271 in -Ib Mcap=12691 in -Ib 0.65 -OK Brace -Horizontal Fy=55 ksi Hannibal 1-1/2x1-1/2x16ga 0.18-0K Brace -Diagonal Fy=55 ksi Hannibal 1-1/2x1-1/2x16ga 0.27-0K Base Plate Fy=36 ksi 8x5x3/8 Fixity= 8000 in -Ib 0.71-0K Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT TZ ESR 1917 Inspection Reqd (Net Seismic Uplift=3064 Ib) 0.775 -OK Slab & Soil 5" thk x 2500 psi slab on grade. 750 psf Soil Bearing Pressure 0.55-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 2,500 Ib 72.0 in 36.0 in 230 Ib 171 Ib 3,878 Ib 24,292 "# 14,482 "# 4 pin 04. 2 3 2,500 Ib 60.0 in 2,500 Ib 58.0 in 48.0 in 48.0 in 48.0 in 421 Ib 314 Ib 2,585 Ib 11,475 "# 8,271 "# 3 pin OK 606 Ib 451 Ib 1,293 Ib 6,545 "# 4,254 "# 3 pin OK ** Load defined as product weight per pair of beams Notes Total: 1,256 Ib 936 Ib YAMATO-TYPE I SELECTIVE RACK Page of 2 Sr 7/10/2017 StrAtural kdoncepts ii Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.5961186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Seismic Forces Configuration: TYPE 1 SELECTIVE RACK Lateral analysis is performed with regard to the requirements of the 2012 RMI ANSI MH 16.1-2012 Sec 2.6 & ASCE 7-10 sec 15.5.3 Transverse (Cross Aisle) Seismic Load V= Cs*Ip*Ws=Cs*Ip*(0.67*P*Prf+D) Cs1= Sds/R = 0.2378 Cs2= 0.044*Sds = 0.0419 Cs3= 0.5*S1/R = 0.0665 Cs -max= 0.2378 Base Shear Coeff=Cs= 0.2378 Level 1 2 3 PRODUCT LOAD P 2,500 Ib 2,500 Ib 2,500 Ib Cs -max * Ip= 0.2378 Vmin= D.015 Eff Base Shear=Cs= 0.2378 Transverse Elevation Ws= (0.67*PLRF1 * PL)+DL (RMI 2.6.2) = 5,280 lb Vt P*0.67*PRF1 1,675 Ib 1,675 Ib 1,675 lb Vtransv=Vt= 0.2378 * (255 Ib + 5025 Ib) Etransverse= 1,256 Ib Limit States Level Transverse seismic shear per upright DL 85 Ib 85 Ib 85 Ib hi 72 in 132 in 190 in wi*hi 126,720 232,320 334,400 Ss= 1.427 S1= 0.532 Fa= 1.000 Fv= 1.500 Sds=2/3*Ss*Fa= 0.951 Sd1=2/3*S1*Fv= 0.532 Ca=0.4*2/3*Ss*Fa= 0.3805 (Transverse, Braced Frame Dir.) R= 4.0 Ip= 1.0 PRF1= Pallet Height=hp= 48.0 in DL per Beam Lvl= 85 Ib Fi Fi*(hi+hp/2) 229.5 Ib 22,032-# 420.8 Ib 65,645-# 605.7 Ib 129,620-# sum: P=7500 Ib 5,025 Ib Longitudinal (Downaisle) Seismic Load 255 Ib W=5280 Ib 693,440 1,256 Ib 2=217,297 Similarly for longitudinal seismic loads, using R=6.0 Cs1=Sd1/(T*R)= 0.1773 Cs2= 0.0419 Cs3= 0.0443 Cs -max= 0.1773 Level 1 2 3 PRODUC LOAD P 2,500 Ib 2,500 Ib 2,500 Ib Ws= Cs=Cs-max*Ip= (0.67 * PLRF2 * P) + DL 5,280 Ib 0.1773 PRF2= 1.0 (Longitudinal, Unbraced Dir.) R= 6.0 T= 0.50 sec Vlong= Elongitudinal= 0.1773 * (255 Ib + 5025 Ib) 936 lb Limit States Level Longit. seismic shear per upright P*0.67*PRF2 1,675 Ib 1,675 Ib 1,675 Ib DL 85 Ib 85 Ib 851b hi 72 in 132 in 190 in wi*hi 126,720 232,320 334,400 L- -1 Fi 171.0 Ib 313.6 Ib 451.4 Ib Front View sum: 5,025 Ib 255 Ib W=5280 Ib 693,440 936 Ib YAMATO-TY)' E 1 SELECTIVE RACK Pae C of -2-S 7/ 1 0/20 1 7 Str tura) oncepts - —/ Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Downaisle Seismic Loads Configuration: TYPE 1 SELECTIVE RACK Determine the story moments by applying portal analysis. The base plate is assumed to provide partial fixity. Seismic Story Forces Vlong= 936 Ib Vcol=Vlong/2= 468 Ib F1= 171 Ib F2= 314 Ib F3= 451 Ib Seismic Story Moments Typical frame made Trihutarvarca o(twocolumn, of rack frame 4 F t -4 96 —01 Front Vicw Conceptual System 5idc Vicw Typical Framc made of two columns fT fl Top View rJ�fl COL Mbase-max= 8,000 in -Ib <=== Default capacity Mbase-v= (Vcol*hleff)/2 = 16,146 in -Ib <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v = 8,000 in -Ib M 1-1= [Vcol * hieff]-Mbase-eff = (468 Ib * 69 in) -8000 in -Ib = 24,292 in -Ib Mseis= (Mupper+Mlower)/2 Mseis(1-1)= (24292 in -Ib + 11475 in-Ib)/2 = 17,884 in -Ib hl-eff= h1 - beam clip height/2 = 69 in M 2-2= [Vcol-(F1)/2] * h2 = [468 Ib - 156.8 Ib]*60 in/2 = 11,475 in -Ib Mseis(2-2)= (11475 in -Ib + 6545 in-Ib)/2 = 9,010 in -lb Vcol Beam to Column Elevation rho= 1.0000 Summary of Forces LEVEL hi Axial Load 1 72 in 3,878 Ib 2 60 in 2,585 Ib 3 58 in 1,293 Ib Column Moment** 24,292 in -Ib 11,475 in -Ib 6,545 in -Ib Mseismic** Mend -fixity Mconn** 17,884 in -Ib 2,805 in -Ib 14,482 in -Ib 9,010 in -Ib 2,805 in -Ib 8,271 in -Ib 3,273 in -Ib 2,805 in -Ib 4,254 in -Ib Beam Connector 3 pin NG 3 pin OK 3 pin OK Mconn= (Mseismic + Mend-fixity)*0.70*rho Mconn-allow(3 Pin)= 12,691 in -Ib **all moments based on limit states level loading YAMATO-TYPE 1 SELECTIVE RACK Page (p of 2 7/10/2017 Str tural ',oncepts Engineering By: BOB S. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 Project: YAMATO Project #: R-070617-11Iv Column (Longitudinal Loads) Configuration: TYPE 1 SELECTIVE RACK., Section Properties Section: Hannibal IF3014-3x3x14ga Aeff = 0.643 in^2 Ix = 1.130 in^4 Sx = 0.753 in^3 rx = 1.326 in Qf= 1.67 E= 29,500 ksi Loads Considers loads at level 1 Iy = 0.749 in^4 Sy = 0.493 in^3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 70.3 in Ky = 1.0 Ly = 36.0 in Cb= 1.0 COLUMN DL= 127 Ib COLUMN PL= 3,750 Ib Mcol= 24,292 in -Ib Sds= 0.9513 1+0.105*Sds= 1.0999 1.4+0.14Sds= 1.5332 1+0.14Sds= 1.1332 0.85+0.14*Sds= 0.9832 B= 0.7000 rho= 1.0000 Axial Analysis Critical load cases are: RMI Sec 2.1 Load Case 5: : (1+0.105*Sds)D + 0.75*(1.4+0.145ds)*B*P + 0.75*(0.7*rho*E)<= 1.0, ASD Method axial load coeff: 0.80492055 * P seismic moment coeff: 0.5625 * Mcol Load Case 6: : (1+0.104*Sds)D + (0.85+0.14Sds)*B*P + (0.7*rho*E)<= 1.0, ASD Method axial load coeff: 0.68823 seismic moment coeff: 0.7 * Mcol By analysis, Load case 6 governs utilizing loads as such Axial Load=Pax= 1.133182*127 Ib + 0.983182*0.7*3750 Ib = 2,725 Ib Moment=Mx= 0.7*rho*Mcol = 0.7 * 24292 in -Ib = 17,004 in -Ib KxLx/rx = 1.7*70.3125"/1.326" KyLy/ry = 1*36"/1.08" = 90.1 = 33.3 Fe= n^2E/(KL/r)max^2 = 35.8ksi Pn= Aeff*Fn = 21,793 Ib P/Pa= 0.24 > 0.15 Bending Analysis Fy/2= 27.5 ksi Qc= 1.92 Fe > Fy/2 Fn= Fy(1-Fy/4Fe) = 55 ksi*[1-55 ksi/(4*35.8 ksi)] = 33.9 ksi Pa= Pn/Qc = 21793 Ib/1.92 = 11,351 Ib Check: Pax/Pa + (Cmx*Mx)/(Max*px) <_ 1.0 P/Pao + Mx/Max _< 1.0 Pno= Ae*Fy = 0.643 in^2 *55000 psi = 35,365 Ib Max= My/4f = 41415 in-Ib/1.67 = 24,799 in -Ib px= {1/[1-(Qc*P/Pcr)]}^-1 = {1/[1-(1.92*2725 Ib/23027 Ib)]}^ -1 = 0.77 Combined Stresses Pao= Pno/Qc = 353651b/1.92 = 18,419 Ib Myield=My= Sx*Fy = 0.753 in^3 * 55000 psi = 41,415 in -Ib Pcr= n^2EI/(KL)max^2 = n^2*29500 ksi/(1.7*70.3125 in)^2 = 23,027 Ib (2725 Ib/11351 Ib) + (0.85*17004 in-lb)/(24799 in-Ib*0.77) = 0.99 < 1.0, OK (EQ C5-1) (2725 Ib/18419 Ib) + (17004 in-lb/24799 in -Ib) = 0.83 . < 1.0, OK (EQ C5-2) ** For comparison, total column stress computed for load case 5 is: 870% q loads 3158.137648 lb Axial and M= 12753 in -lb YAMATO-TYPE 1 SELECTIVE RACK Page 7, / of L 7/10/2017 Str tural on is �ng ineering 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Transverse Column Configuration: TYPE 1 SELECTIVE RACK Section Properties Load at level= 1 Section: Hannibal IF3014-3x3x14ga Aeff = 0.643 in^2 Ix = 1.130 in^4 Sx = 0.753 inA3 rx = 1.326 in S2f= 1.67 E= 29,500 ksi Cb= 1.0 Kx = 1.7 Ky = 1.0 Loads Iy = 0.749 in^4 Sy = 0.493 in^3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 width= 3.000 in depthl= 3.000 in thickl= 0.0750 in Lx = 70.3 in Ly = 36.0 in 3.0" 3.0" 0 75" Transverse Elevation COLUMN DL= 128 Ib COLUMN PL= 3,750 Ib Sds= 0.9513 1+0.105*Sds= 1.0999 1.4+0.14Sds= 1.5332 1+0.14Sds= 1.1332 0.85+0.14*Sds= 0.9832 B 0 700D rho= 0000 Movt= 217,297 in -Ib Frame Depth=D= 44 in Seismic Axial=Pv= Movt/D = 4,939 Ib Axial Analysis Critical load cases are: RMI Sec 2.1 Load Case 5:: (1+0.105*Sds)D + 0.75*(1.4+0.14Sds)*B*P + 0.75*(0.7*rho*E)<= 1.0, ASO Method Load Case 6: : (1+0.104*Sds)D + (0.85+0.14Sds)*B*P + (0.7*rho*E)<= 1.0, ASD Method Load Case 5: Axial Load= 1.0998865*127.5 Ib + 0.75*(1.533182*0.7*3750 Ib) + 0.75*(0.7*rho*4939 Ib) = 5,752 Ib Load Case 6: Axial Load= 1.133182*127.5 Ib + 0.983182*0.7*3750 Ib + (0.7*rho*4939 Ib) = 6,183 Ib Eff. Axial Load= 6,183 Ib KxLx/rx = 1.7*70.3125"/1.326" = 90.1 Fe= n^2E/(KL/r)max^2 = 35.8ksi Pn= Aeff*Fn = 21,793 Ib P/Pa= 0.54 > 0.15 Bending Analysis KyLy/ry = 1*36"/1.08" = 33.3 Fy/2= 27.5 ksi Qc= 1.92 Fe > Fy/2 Fn= Fy(1-Fy/4Fe) = 55 ksi*[1-55 ksi/(4*35.8 ksi)] = 33.9 ksi Pa= Pn/Qc = 21793lb/1.92 = 11,351 Ib Check: P/Pa + (Cmy*My)/(May*py) <_ 1.0 P/Pao + My/May <_ 1.0 Pno= Ae*Fy = 0.643 in^2 *55000 psi = 35,365 Ib May= My/Qf = 27115 in-lb/1.67 = 16,237 in -Ib px= {1/[1-(S2c*P/Pcr)]}^-1 = {1/[1-(1.92*6183 Ib/23027 Ib)]}^ -1 = 0.48 Combined Stresses Pao= Pno/Qc Myield=My= Sy*Fy = 353651b/1.92 = 0.493 in^3 * 55000 psi = 18,419 Ib = 27,115 in -Ib Pcr= n^2EI/(KL)max^2 = nA2*29500 ksi/(1.7*70.3125 in)^2 = 23,027 Ib (6183 Ib/11351 Ib) + (0.85*0 in-Ib)/(16237 in-Ib*0.48) = (6183 Ib/18419 Ib) + (0 in-Ib/16237 in -Ib) = 0.54 < 1.0, OK 0.34 < 1.0, OK (EQ C5-1) (EQ C5-2) Page Z of 2 S-- A Strititural on is ngineering 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project M R -070617-11(v BEAM Contiguration: TYPE 1 SELECTIVE RACK DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (B2.1) w= c - 2*t -2*r = 1.625 in - 2*0.06 in - 2*0.06 in = 1.385 in w/t= 23.08 1=lambda= [1.052/(k)^0.5] * (w/t) * (Fy/E)^0.5 = [1.052/(4)^0.5] * 23.08 * (55/29500)^0.5 = 0.524 < 0.673, Flange is fully effective B) check web for local buckling per section b2.3 fl(comp)= Fy*(y3/y2)= 49.25 ksi f2(tension)= Fy*(y1/y2)= 101.01 ksi Y= f2/f1 Eq. B2.3-5 = -2.051 k= 4 + 2*(1-Y)^3 + 2*(1-Y) Eq. B2.3-4 = 66.90 flat depth=w= y1+y3 = 3.135 in w/t= 52.25 1=lambda= [1.052/(k)^0.5] * (w/t) * (f1/E)^0.5 = [1.052/(66.9)^0.5] * 3.135 * (49.25/29500)^0.5 = 0.275 < 0.673 be=w= 3.135 in b2= be/2 b1= be(3-Y) = 1.57 in = 0.621 bl+b2= 2.191 in ' > 1.0275 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya= C*Fyc + (1-C)*Fy (EQ A7.2-1) Lcorner=Lc= (p/2) * (r + t/2) 0.141 in C= 2*Lc/(Lf+2*Lc) Lflange-top=Lf= 1.385 in = 0.169 in m= 0.192*(Fu/Fy) - 0.068 (EQ A7.2-4) = 0.1590 Bc= 3.69*(Fu/Fy) - 0.819*(Fu/Fy)^2 - 1.79 = 1.427 since fu/Fv= 1.18 < 1.2 and r/t= 1 < 7 OK then Fyc= Bc * Fy/(R/t)^m (EQ A7.2-2) = 78.485 ksi Thus, Fya-top= 58.97 ksi (tension stress at top) Fya-bottom= Fya*Ycg/(depth -Ycg) = 114.48 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange-bot=Lfb= Lbottom - 2*r*-2*t = 2.510 in Cbottom=Cb= 2*Lc/(Lfb+2*Lc) = 0.101 Fy-bottom=Fyb= Cb*Fyc + (1-Cb)*Fyf 57.37 ksi Fya= (Fya-top)*(Fyb/Fya-bottom) = 29.56 ksi if F= 0.95 Then F*Mn=F*Fya*Sx= Eq. B2.1-4 Eq. B2.1-1 OK Eq B2.3-2 (EQ A7.2-3) 3.375 i 2.75 in 1.63 in Beam= HMH 33160/3.375" Face x 0.06" thk depth 15.86 in -k y2 y3 Ix= Sx= Ycg= t= Bend Radius=r= Fy= Fyv= Fu=Fuv= E= top flange=b= bottom flange= Web depth= ft (camp) 1.042 in^4 0.565 in^3 2.228 in 0.060 in 0.060 in 55.00 ksi 65.00 ksi 29500 ksi 1.625 in 2.750 in 32-/C Fy Ycg f2(tension) yl= Ycg-t-r= 2.108 in y2= depth-Ycg= 1.148 in y3= y2 -t -r= 1.028 in g'� Str tura) eon is ngineering 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv BEAM Configuration: TYPE 1 SELECTIVE RACK RMI Section 5.2, PT II Section Beam= HMH 33160/3.375" Face x 0.06" thk Ix=Ib= 1.042 inA4 Sx= 0.565 in^3 t= 0.060 in Fy=Fyv= 55 ksi Fu=Fuv= 65 ksi Fya= 59.0 ksi E= 29500 ksi F= 250.0 L= 96 in Beam Level= 1 P=Product Load= 2,500 Ib/pair D=Dead Load= 85 Ib/pair 1. Check Bending Stress Allowable Loads Mcenter=F*Mn= W*L*W*Rm/8 W=LRFD Load Factor= 1.2*D + 1.4*P+1.4*(0.125)*P RMI2.2, item 8 FOR DL=2% of PL, W= 1.599 Rm= if F= Then F*Mn=F*Fya*Sx= Thus, allowable load per beam pair=W= Mend= 1 - [(2*F*L)/(6*E*Ib + 3*F*L)] 1 - (2*250*96 in)/[(6*29500 ksi*1.0418 inA3)+(3*250*96 in)] 0.813 . 0.95 31.65 in -k F*Mn*8*(# of beams)/(L*Rm*W) 31.65 in -k * 8 * 2/(96in * 0.813 * 1.599) 4,058 Ib/pair allowable load based on bending stress W*L*(1-Rm)/8 (4058 Ib/2) * 96 in * (1-0.813)/8 = 4,553 in -Ib = 2,805 in -Ib @ 4058 Ib max allowable load @ 2500 Ib imposed product load 2. Check Deflection Stress Allowable Loads 3.375 in 2.75 in 1.63 in 111111111111111111111111111111111111111111110 Dmax= Dss*Rd Rd= 1 - (4*F*L)/(5*F*L + 10*E*Ib) = 1 - (4*250*96 in)/[(5*250*96 in)+(10*29500 ksi*1.0418 in^4)] = 0.775 in if Dmax= L/180 Based on L/180 Deflection Criteria and Dss= 5*W*L^3/(384*E*Ib) L/180= 5*W*LA3*Rd/(384*E*Ib*# of beams) solving for W yields, W= 384*E*I*2/(180*5*L^2*Rd) = 384*1.0418 inA4*2/[180*5*(96 in)^2*0.775) = 3,672 Ib/pair allowable load based on deflection limits Thus, based on the least capacity of item 1 and 2 above: Allowable Deflection= L/180 = 0.533 in Deflection at imposed Load= 0.363 in Allowable Toad= 3,6721 lb/pair Imposed Product Load= 2,500 Ib/pair !Beam Stress= 0.68 Beam at Level 1 ti. Stru tura) / t s ngineering 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project /1: R-0706 17- 4 Pin Beam to Column Connection TYPE 1 SELECTIVE RACK 1 he beam end moments shown herein show the result ot the maximum induced fixed end monents torm seismic + static loads and the code mandated minimum value ot 1.5%(DL+PL) Mconn max= (Mseismic + Mend-fixity)*0.70*Rho = 14,318 in -Ib Load at level 1 Connector Type= 4 Pin Shear Capacity of Pin P1 P3 2"17P v2" rho= 1.0000% Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)A2 * Pi/4 = 0.1507 inA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507inA2 3,315 Ib Bearing Capacity of Pin tcol= 0.075 in Fu= 65,000 psi Omega= 2.22 a= 2.22 Pbearing= alpha * Fu * diam * tcol/Omega = 2.22 * 65000 psi * 0.438 in * 0.075 in/2.22 = 2,135 Ib < 3315 Ib Moment Capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in Fy= 55,000 psi C= P1+P2+P3+P4 tclip= 0.18 in = P1+P1*(4.5"/6.5")+P1*(2.5"/6.5")+P1*(0.5"/6.5") = 2.154 * P1 Mcap= Sclip * Fbending = 0.127 inA3 * 0.66 * Fy = 4,610 in -Ib Pclip= Mcap/(2.154 * d) = 4610.1 in-lb/(2.154 * 0.5 in) = 4,281 Ib C*d= Mcap = 2.154 Thus, P1= 2,135 Ib Mconn-allow= [P1*6.5"+P1*(4.5"/6.5")*4.5" +P1*(2.5"/6.5")2.5" +P1*(0.5"/6.5")*0.51 • = 2135 LB*[6.5"+(4.5"/6.5")*4.5"+(2.5"/6.5")*2.5"+(0.5"/6.5")*0.51 = 22,664 in -Ib > Mconn max, OK Sclip= 0.127 inA3 d= E/2 = 0.50 in YAMATO-TYPE I SELECTIVE RACK Page f./ of 7/10/2017 Stru tural is Y ngineering 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 Dy: BOB S. Project: YAMATO Project #: R-0706 17- 3 Pin Beam to Column Connection TYPE 1 SELECTIVE RACK I he beam end moments shown herein show the result of the maximum induced tixed end monents form seismic + static loads and the code mandated minimum value of 1.5%(DL+PL) Mconn max= (Mseismic + Mend-fixity)*0.70*Rho = 8,271 in -Ib Load at level 2 Connector Type= 3 Pin Shear Capacity of Pin P1 1•• P P3 J 7 1/2 '411-111- C 12" rho=11.0000'' Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)^2 * Pi/4 = 0.1507 in^2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507in^2 = 3,315 Ib Bearing Capacity of Pin tcol= 0.075 in Fu= 65,000 psi Omega= 2.22 a= 2.22 Pbearing= alpha * Fu * diam * tcol/Omega = 2.22 * 65000 psi * 0.438 in * 0.075 in/2.22 = 2,135 lb < 3315 lb Moment Capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in Fy= 55,000 psi c= P1+P2+P3 tclip= 0.18 in = P1+P1*(2.5"/4.5")+P1*(0.5"/4.5") = 1.667 * P1 Mcap= Sclip * Fbending =0.127in^3*0.66*Fy = 4,610 in -lb Pclip= Mcap/(1.667 * d) = 4610.1 in-lb/(1.667 * 0.5 in) = 5,531 Ib C*d= Mcap = 1.667 Thus, P1= 2,135 lb Mconn-allow= [P1*4.5"+P1*(2.5"/4.5")*2.5"+P1*(0.574.5")*0.5"] = 2135 LB*[4.5"+(2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"] = 12,691 in -Ib > Mconn max, OK Sclip= 0.127 in^3 d= E/2 = 0.50 in YAMATO-TYPE I SELECTIVE RACK Page f.2. of Z . ` 7/10/2017 S tr tural oncepts Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Transverse Brace Configuration: TYPE 1 SELECTIVE RACK Section Properties Diagonal Member= Hannibal 1-1/2x1-1/2x16ga Area= 0.273 in^2 ��1.soo in r min= 0.496 in Fy= 55,000 psi K= 1.0 Qc= 1.92 Frame Dimensions .3- 0.25 in Horizontal Member= Hannibal 1-1/2x1-1/2x16ga Area= 0.273 in^2 r min= 0.496 in 7 Fy= 55,000 psi 1.500 in K= 1.0 1.500 4-0.25 in Bottom Panel Height=H= 48.0 in Frame Depth=D= 44.0 in Column Width=B= 3.0 in Diagonal Member Clear Depth=D-B*2= 38.0 in X Brace= NO rho= 1.00 Load Case 6:: (1+ 1 i 0 0.85+0.14Sds)*B*P + [0.7*rho*EJ<= 1.0, ASD Method Vtransverse= 1,256 Ib Vb=Vtransv*0.7*rho= 1256 Ib * 0.7 * 1 = 879 Ib Ldiag= [(D-B*2)^2 + (H-6")^2]^1/2 = 56.6 in Pmax= V*(Ldiag/D) * 0.75 = 8481b axial load on diagonal brace member Pn= AREA*Fn = 0.273 in^2 * 22364 psi = 6,105 Ib Pallow= Pn/4 = 6105 Ib /1.92 = 3,180 Ib Pn/Pallow= Horizontal brace 0.27 <= 1.0 OK Vb (kl/r)= (k * Ldiag)/r min = (1 x 56.6 in /0.496 in )I = 114.1 in Fe= pi^2*E/(kl/r)^2 = 22,364 psi Since Fe<Fy/2, Fn= Fe = 22,364 psi Typical Panel Cpnfignration Check End Weld Lweld= 3.0 in Fu= 65 ksi tmin= 0.060 in Weld Capacity= 0.75 * tmin * L * Fu/2.5 = 3,510 Ib OK Vb=Vtransv*0.7*rho= 879 Ib (kl/r)= (k * Lhoriz)/r min = (1 x 44 in) /0.496 in = 88.7 in Since Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 34,564 psi Pn/Pallow= 0.18 <= 1.0 OK Fe= pi^2*E/(kl/r)^2 = 37,006 psi Pn= AREA*Fn = 0.273in^2*34564 psi = 9,436 Ib Fy/2= 27,500 psi Pallow= Pn/Oc = 9436 Ib /1.92 = 4,915 Ib YAMATO-TYPE 1 SELECTIVE RACK Page l° of L 7/10/2017 Str tura) oncepts Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: BOB S. Project: YAMATO Project #: R-070617-11Iv Single Row Frame Overturning Configuration: TYPE 1 SELECTIVE RACK Loads Critical Load case(s): 1) RMI Sec 2.2, item 7: (0.9-0.2Sds)D + (0.9-0.20Sds)*B*Papp - E*rho Vtrans=V=E=Qe= 1,256 Ib DEAD LOAD PER UPRIGHT=D= 255 Ib PRODUCT LOAD PER UPRIGHT=P= 7,500 Ib Papp=P*0.67= 5,025 Ib Wst LC1=Wst1=(0.70974*D + 0.70974*Papp*1)= 3,747 Ib Product Load Top Level, Ptop= 2,500 Ib DL/Lvl= 85 Ib Seismic Ovt based on E, E(Fi*hi)= 217,297 in -Ib height/depth ratio= 4.3 in Sds= 0.9513 (0.9-0.2Sds)= 0.7097 (0.9-0.2Sds)= 0.7097 B= 1.0000 rho= 1.0000 Frame Depth=Df= 44.0 in Htop-Iv1=H= 190.0 in # Levels= 3 # Anchors/Base= 2 hp= 48.0 in hp • Tt h Df -01 SIDE ELEVATION A) Fully Loaded Rack h=H+hp/2= 214.0 in Load case 1: Movt= £(Fi*hi)*E*rho = 217,297 in -Ib Mst= Wstl * Df/2 T= (Movt-Mst)/Df = 3747 Ib * 44 in/2 = (217297 in -Ib - 82434 in-lb)/44 in = 82,434 in -Ib = 3,065 Ib Net Uplift per Column Net Seismic Uplift= 3,065 Ib B) Top Level Loaded Only Load case 1: 0 V1=Vtop= Cs * Ip * Ptop >= 350 Ib for H/D >6.0 = 0.2378 * 2500 Ib = 595 Ib Vieff= 595 Ib Critical Level= 3 V2=VDL= Cs*Ip*D Cs*Ip= 0.2378 = 61 Ib Mst= (0.70974*D + 0.70974*Ptop*1) * 44 in/2 = 43,017 in -Ib Movt= [V1*h + V2 * H/2]*0.7*rho = 93,089 in -Ib T= (Movt-Mst)/Df = (93089 in -Ib - 43017 in-lb)/44 in = 1,138 Ib Net Uplift per Column Net Seismic Uplift= 1,138 Ib Anchor Check (2) 0.5" x 3.25" Embed HILTI KWIKBOLT TZ anchor(s) per base plate. Special inspection is required per ESR 1917. Pullout Capacity=Tcap= 1,950 Ib L.A. City Jurisdiction? NO Shear Capacity=Vcap= 2,150 Ib Phi= 1 (1532 lb/1950 Ib)^1 + (314 Ib/2150 Ib)^1 = (569 Ib/1950 Ib)^1 + (148 Ib/2150 Ib)^1 = Fully Loaded: Top Level Loaded: Tcap*Phi= 1,950 Ib Vcap*Phi= 2,150 Ib 0.93 <= 1.2 OK 0.36 <= 1.2 OK YAMATO-TYPE I SELECTIVE RACK Page 7/ of L� 7/10/2017 Str tura) oncepts � ngineering By: BOB S. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 Project: YAMATO Project #: R-070617-11Iv Base Plate Configuration: TYPE 1 SELECTIVE RACK Section Baseplate= 8x5x3/8 Eff Width=W = 8.00 in Eff Depth=D = 5.00 in Column Width=b = 3.00 in Column Depth=dc = 3.00 in L = 2.50 in Plate Thickness=t = 0.375 in a = 3.00 in Anchor c.c. =2*a=d = 6.00 in N=# Anchor/Base= 2 Fy = 36,000 psi Downaisle Elevation Down Aisle Loads Load Case 5.• : (1 +0.105*Sds)D + 0.75*1(1.4+0.14Sds)*B*P + 0.75*[0.7*rho*E]<= 1.0, ASD Method COLUMN DL= COLUMN PL= Base Moment= 1+0.105*Sds= 1.4+0.14Sds= B= Axial stress=fa = Moment Stress=fb = Moment Stress=fbl = M3 = S -plate = fb/Fb = Tanchor = Cross Aisle Loads 128 Ib 3,750 Ib 8,000 in -Ib 1.0999 1.5332 0 7000 P/A = P/(D*W) 79 psi M/S = 6*Mb/[(D*B^2] 78.8 psi fb-fb2 29.5 psi (1/2)*fb2*L*(2/3)*L = (1/3)*fb2*L^2 103 in -Ib (1)(t^2)/6 0.023 inA3/in M tota l/ [ (S -plate) (Fb) ] 0.70 OK (Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2] -1,174 Ib No Tension Critical load case RMI Sec 2.1, item 4.' (I+0.115ds)DL + (1+0.14505)PL *0.75+EL*0.75 <= 1.0,15D Method Axial=P= 1.0998865 * 127.5 Ib + 0.75 * (1.533182 * 0.7 * 3750 Ib) = 3,159 1b Mb= Base Moment*0.75*0.7*rho = 8000 in -Ib * 0.75*0.7*rho = 4,200 in -Ib Axial Load P = 3,159 Ib Mbase=Mb = 4,200 in -Ib M1= wL^2/2= fa*L^2/2 = 247 in -Ib Moment Stress=fb2 = 2 * fb * L/W = 49.2 psi M2= fb1*L^2)/2 = 92 in -Ib Mtotal = M1+M2+M3 = 442 in-Ib/in Fb = 0.75*Fy. = 27,000 psi F'p= 0.7*F'c = 1,750 psi OK Tallow= 1,950 Ib OK Check uplift load on Baseplate Eff Effe Pstatic= 3,159 Ib Movt*0.75*0.7*rho= 114,081 in -Ib Frame Depth= 44.0 in P=Pstatic+Pseismic= 5,751 Ib b =Column Depth= 3.00 in L =Base Plate Depth -Col Depth= 2.50 in fa = P/A = P/(D*W) = 144 psi Sbase/in = (1)(t^2)/6 = 0.023 in^3/in fb/Fb = M/[(S-plate)(Fb)] 0.71 OK Pseismic= Movt/Frame Depth = 2,593 Ib M= wLA2/2= fa*L^2/2 = 449 in-Ib/in Fbase = 0.75*Fy = 27,000 psi Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. 'When the base plate configuration consists of two anchor bolts located on either side f the column and a net uplift force exists, the minimum base plate thickness hall be determined based on a design bending moment in the plate equal o the uplift force on one anchor times 1/2 the distance from he centerline of the anchor to the nearest edge of the rack column" T Ta Elevation Uplift per Column= 3,064 Ib Qty Anchor per BP= 2 Net Tension per anchor=Ta= 1,532 Ib c= 2.50 in Mu=Moment on Baseplate due to uplift= Ta*c/2 = 1,915 in -Ib Splate= 0.117 in^3 fb Fb *0.75= 0.454 OK YAMATO-TYPE 1 SELECTIVE RACK Page. `Z of 2 7/10/2017 By: BOB S. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 Project: YAMATO Project #: R-070617-11Iv Slab on Grade Configuration: TYPE 1 SELECTIVE RACK IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIuiIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Base Plate Effec. Baseplate width=B= 8,00 in Effec. Baseplate Depth=D= 5.00 in Column Loads slab ral e I , : B .... Down Aisle Baseplate Plan View Cross • Aisle width=a= 3.00 in depth=b= 3.00 in midway dist face of column to edge of plate=c= 5.50 in midway dist face of column to edge of plate=e= 4.00 in Concrete fc= 2,500 psi tslab=t= 5.0 in teff= 5.0 in phl = 06 Soil fsoil= 750 psf Movt= 152,108 in -Ib Frame depth= 44.0 in Sds= 0.951 0.2*Sds= 0.190 0 600 R=B/D= 1.600 Pc^0.5= 50.00 psi DEAD LOAD=D= PRODUCT LOAD=P= Papp= P-seismic=E= B rho= Sds= 1.2 + 0.2*Sds= 0. 9 - 0.20Sds= Puncture 128 Ib per column unfactored ASD load 3,750 Ib per column unfactored ASD load 2,513 Ib per column (Movt/Frame depth) 3,456 Ib per column unfactored Limit State load 0.:7000 1.0000 0.9513 1.3903 0.7097 Load Case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E RMI SEC 2.2 EQTN 5 = 1.39026 * 128 Ib + 1.39026 * 0.7 * 3750 Ib + 1 * 3456 Ib = 7,283 Ib Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E RMI SEC 2.2 EQTN 7 = 0.70974 * 128 Ib + 0.70974 * 0.7 * 2512.5 Ib + 1 * 3456 Ib = 4,795 Ib Load Case 3) 1.2*D + 1.4*P RMI SEC 2.2 EQTN 1,2 = 1.2*128 Ib + 1.4*3750 Ib = 5,403 Ib Load Case 4) 1.2*D + 1.0*P + 1.0E = 7,360 Ib Effective Column Load=Pu= 7,360 Ib per column ACT 318-11 Sec 9.2.1, E9m 9-5 Apunct= [(c+t)+(e+t)]*2*t = 195.0 in^2 Fpunctl= [(4/3 + 8/(3*p)] * k *(F'c^0.5) = 90. psi Fpunct2= 2.66 * X * (F'c^0.5) = 79.8 psi Fpunct eff= 79.8 psi Slab Bending fv/Fv= Pu/(Apunct*Fpunct) = 0.473 < 1 OK Pse=DL+PL+E= 7,360 Ib Asoil= (Pse*144)/(fsoil) = 1,413 in^2 x= (L -y)/2 = 11.4 in Fb= 5*(phi)*(fc)^0.5 = 150. psi L= (Asoil)^0.5 = 37.59 in M= w*x^2/2 = (fsoil*x^2)/(144*2) = 341.4 in -Ib y= (c*e)^0.5 + 2*t = 14.7 in S -slab= 1*teff^2/6 = 4.17 in^3 fb/Fb= M/(S-slab*Fb) = 0.546 < 1, OK YAMATO-TYPE I SELECTIVE RACK Page 0 of 24 7/10/2017 Str tural oncepts Engineering 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: YAMATO Project #: R-070617-11Iv Configuration & Summary: TYPE 2 SELECTIVE RACK 192" 1 58" 60" 72" 48" 48" 192" 48" 36" 144" -I" 44" 44" 4 **RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 150 /b AXIAL LL= 3,625/b SEISMIC AXIAL Ps=+/- 5,063 Ib BASE MOMENT= 6,000 /n -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.427, Fa=1 3 44 in 192.0 in 4 144 in Single Row Component Description STRESS Column Fy=55 ksi Hannibal IF3014-3x3x14ga P=3775 Ib, M=23533 in -Ib 0.95-0K Column & Backer None None None N/A Beam Fy=55 ksi HMH 50160/5" Face x 0.06" thk Lu=144 in Capacity: 3895 Ib/pr 0.77-0K Beam Connector Fy=55 ksi LvI 2: 3 pin OK Mconn=8934 in -Ib Mcap=12691 in -Ib 0.7-0K Brace -Horizontal Fy=55 ksi Hannibal 1-1/2x1-1/2x16ga 0.17-0K Brace -Diagonal Fy=55 ksi Hannibal 1-1/2x1-1/2x16ga 0.26-0K Base Plate Fy=36 ksi 8x5x3/8 Fixity= 8000 in -Ib 0.71-0K Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT TZ ESR 1917 Inspection Reqd (Net Seismic Uplift=3232 Ib) 0.808 -OK Slab & Soil 5" thk x 2500 psi slab on grade. 750 psf Soil Bearing Pressure 0.54-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. . Moment Beam Connector 2 3 3,000 Ib 60.0 in 3,000 Ib 58.0 in 48.0 in 48.0 in 48.0 in 457 lb 341 Ib 3,100 lb 12,471 "# 8,934 "# 3 pin OK 658 Ib 491 Ib 1,550 Ib 7,114 "# 4,569 "# 3 pin OK ** Load defined as product weight per pair of beams Notes Total: 1,226 Ib 914 Ib INT TUNNEL BAY YAMATO-TYPE 2 SELECTIVE RACK Page f� of 2- S 7/10/2017 Structural Concepts Engineering 1815 Wright Ave., La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.593.8561 Cantilever Rack Analysis Str turas onccets ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 Ry• Bob S Design Data Prosect: Yamamoto Configuration: SGL SIDED CANTILEVER RACK Prnjeet #. R -070617 - 1) The analysis presented herein conforms to the requirements of the 2015 IBC, 2013 CBC and ASCE 7-10 2) W & S Shape steel conforms to ASTM A572, Gr. 50, with minimum yield, Fy= 50 ksi Formed steel conforms to ASTM A570, Gr. 50, with minimum yield, Fy= 50 ksi Other steel conforms to ASTM A36, Gr. 36, with minimum yield, Fy= 36 ksi 3) Bolts shall conform to ASTM A325 -N unless noted otherwise on the plans or calculations. 4) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. Installer must provide any special inspection as called out on plans or calculations, or as required by the ICC report indicated herein. 5) AH welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 6) 5 in Thk x 2500 psi slab with 750 psf soil bearing pressure Seismic Design Coefficient Ss= 1.4240 S1= 0.5310 Fa= 1.0000 Fv= 1.5000 Sds= 0.9490 Sd1= 0.5310 1J 1 Str tural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project: Yamamoto Project #: R -070617 - Summary of Results Configuration: SGL SIDED CANTILEVER RACK 1 SIDE VIEW Seismic CoeffSs= 1.424 Seismic Coeff Fa= 1.000 60° T FRONT VIEW T Rack Dimensions & Loads Arm Elev Unif. Arm Load h1 72 in 650 Ib h2 132 in 650 Ib h3 184 in 650 Ib Summary of Components & Results Column Fy=50 ksi W8x18 0.31 OK Base Fy=50 ksi W8x18 0.29 OK Arm • Fy=50 ksi S3x5.7# _ 0.51 OK Arm Connection (4) 3/4" Diam Bolts, Grade 5 or better 0.13 OK Brace Fy=50 ksi X Brace: Strap 2x7ga Strut L2 -1/2x2 -1/2x3/16 0.04 OK X Brace Connection Bolted (1) 0.5 in diam Bolt per end 0.10 OK Anchors ESR 1917 0.625 in diam x 4 in embed Hilti Kwikbolt TZ with inpsection 4 per base 0.44 OK Slab & Soil 5 in thick x 2500 psi with 750 psf soil at grade 0.06 OK Notes ALL LOADS SHOWN ARE PER ARM, UNIFORM LOAD, NO TIP LOADS, NO DROPPED LOADS, NO IMPACT LOADS Page /1 of 21— Str tural td onceis 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632:7763 By: Bob 5 Seismic Loads Project:Yamamoto Project #: R -070617 - Configuration: SGL SIDED CANTILEVER RACK Seismic Eqtn: Transverse Longitudinal Cs1= Sds*I/R = 0.759 0.292 Cs2= 0.044*Sds*I = 0.042 0.042 Cs3= 0.5*S1*I/R = 0.212 0.082 Vtrans= 0.7592 Vlong= 0.2920 Arm LL= 1,950 Ib E Arm LL*phi= 1,307 Ib E Arm uL= 303 Ib V-transv= 0.7592 * 1610 Ib = 1,2221b/frame tranv shear per upright Rtrans= 1.25 Rlong= 3.25 # Sides=n= 1 # Arms= 3 W 1 = Warm,gravity= 2,253 Ib Ss= 1.424 S1= 0.531 Fa= 1.000 Fv= 1.500 Sds= 0.949 Sdl= 0.531 I= 1.0 phi= 0.67 ** DL per arm= 101.0 Ib Side Elevation W2=Warm,seismic= 1,610 Ib ** weight of arm plus trib weight of column per level V-Iong= 0.292 * 1610 Ib = 470 Ib/frame iongit shear per upright V Lateral Force Distribution Transverse Force Longitudinal Force Level 1 2 3 W1 (DL+LL)*n W2 (DL+LL*phi) hx wxhx Fi Fi* hi Fi 751 Ib 537 Ib 72 in 38628 227 Ib 16,344 in -Ib 751 Ib 537 Ib 132 in 70818 416 Ib 54,874 in -Ib 751 Ib 537 Ib 184 in 98716 579 Ib 106,536 in -Ib 87 Ib 160 Ib 223 Ib E= 208,162 1,222 Ib 177,753 in -Ib Summary of Frame Loads Mseismic= 177,753 in -Ib Marm-max= (LL-max+DL) * (Arm Length/2) Mwind= 42,701 in -Ib = (650 Ib + 50 Ib) * (48 in/2) Pcol= 2,253 Ib DL+LL = 16,800 in -Ib Marm-total= E Marm = 50,400 in -Ib Page a$ of Zs' Sttural 4J once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project: Ya ma moto Project #: R -070617 - Arm Configuration: SGL SIDED CANTILEVER RACK Analysis is based on a uniformly loaded arm with no tip or impact loads considered. Arm Type= S3x5.7# Ix= 2.5200 inA4 Sx= 1.680 in^3 Fy= 50,000 psi L= 48 in Check Arm Bending LL -max= 650 Ib DL= 50 Ib M= W * L/2 = 16,800 in -Ib fb= M/Sy = 10,000 psi Fb= 0.6 * Fy 30,000 psi fb/Fb= 0.33 Check Bolts For Imposed Arm Loads OK Check Arm Deflection L W E= 29,000,000 psi D= w * L^4/(8 * E * Ix) = 0.1367 in Dallow= L/180 = 0.27 in OK Spacing=d= 4.0 in Bolt diameter= 0.75 in Ft= 44,000 psi Fv= 28,000 psi tmin= 0.188 in Fu= 58,000 psi # Bolts in shear=Ns= 4 # Bolts in tension=Nt= 2 M= 16,800 in -Ib T= M/d = 4,200 Ib W= LL+DL = 700 Ib W/Bolt= 175 Ib T/Bolt= 2,100 Ib Shear Capacity= Bolt Area * Fv = [(0.75 in)A2 * pi/4] * 28000 psi = 12,370 Ib Bearing Capacity= Bolt Diam * tmin * Fu * 1.2 = 9,788 Ib Tension Capacity= Bolt Area * Ft = 19,439 Ib Combined stresses: Arm to Column Connection (175 Ib/9788 Ib) + (2100 Ib/19439 Ib)= 0.13 OK Column Bolt Arm Page (' of L S � r Strjaitural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project:Yamamoto Column Load Case: DL+LL Configuration: SGL SIDED CANTILEVER RACK Project #: R -070617 - Section Section= W8x18 Area= 5.26 in^2 Ix= 61.90 inA4 Sx= 15.20 inA3 rx= 3.43 in Loads (,Single Face Rack -Full Static Arm Loads) Iy= 7.97 in^4 Sy= 3.04 inA3 ry= 1.23 in Fy= 50,000 psi Kx= 1.5 Ky= 1.0 Lx= 184 in Ly= 60 in Cm= 1.00 Check Load Case 2 ASCE 1.4.1:: DL + LL <= 1.0, ASD Method Pmax= 2,253 Ib Mstatic= 50,400 in -Ib Combined Sress COLUMN DL= 303 Ib COLUMN PL= 1,950 Ib Mstatic= 50,400 in -Ib (kl/r)x = (1.5*184 in/3.43 in) (kl/r)y = (1*60 in/1.23 in) (kl/r)max= 80.47 = 80.47 = 48.78 Cc = (2n^2E/Fy)^0.5 = 107.0 SINCE (KL/r)max < Cc, USE EQTN E2-1 Fa = f1-((kl/r)^2/2Cc^2)1Fy 5/3 + 3(kl/r)/8Cc - (kl/r)^3/8Cc^3 = 18,919 psi fbx= M/S = 3,316 psi F'ex= (12*nA2*E)/(23*(KL/r)^2) = 23,063 psi Fbx= 0.6*Fy = 30,000 psi fa= P/AREA = 428 psi fa/Fa= 0.02 < 0.15 fb/Fb= 0.11 (1-fa/F'e)>0= 1.00 (H1-3): fa/Fa + fb/Fb= Check Base Bending 0.13 <= 1 OK Section= W8x18 Sx= 15.20 inA3 Mbase-static= 50,400 in -Ib Fy= 50,000 psi Fbx= 0.6*Fy = 30,000 psi fb/Fb= 0.11 OK Page 70 of 2.1 StrAtural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project: YamaMato Project #: R -070617 - Column Load Case: DL+LL+ Lateral Load Configuration: SGL SIDED CANTILEVER RACK Section Section= W8x18 Area= 5.26 inA2 Ix= 61.90 inA4 Sx= 15.20 in^3 rx= 3.43 in Iy= 7.97 in^4 Sy= 3.04 in^3 ry= 1.23 in Stress Increase= 1.00 Loads (Single Face Rack -Full Arm Loads plus lateral loads) Fy= 50,000 psi Kx= 15` Ky= 1.0 Lx= 184 in Ly= 60 in Cm= 1.00 Check Load Case 6b ASCE 12.4.2.3: : (1 +0.10*Sds)D + 0.75L + 0.525E<= 1.0, ASD Method Pmax= 1.09 * 303 Ib + 0.75 * 1950 Ib = 1,793 Ib M= 0.75*50400 in -Ib + 177753 in -Ib * 0.525 = 131,120 in -Ib (Mstatic + Mseismic) Combined Sress COLUMN DL= 303 Ib COLUMN PL= 1,950 Ib Mstatic= 50,400 in -Ib Mseismic= 177,753 in -Ib Sds= 0.9490 1+0.10*Sds= 1.0900 (kl/r)x = (1.5*184 in/3.43 in) (kl/r)y = (1*60 in/1.23 in) = 80.47 Cc = (2n^2E/Fy)^0.5 = 107.0 SINCE (KL/r)max < Cc, USE EQTN E2-1 Fa = f1-((kl/r)^2/2Cc^2)]Fy 5/3 + 3(kl/r)/8Cc - (kl/r)^3/8Cc^3 = 18,919 psi fbx= M/S = 8,626 psi F'ex= (12*n^2*E)/(23*(KL/r)^2) = 23,063 psi = 48.78 (kl/r)max= 80.47 Fbx= 0.6*Fy = 30,000 psi fa= P/AREA = 341 psi fa/Fa= 0.02 < 0.15 fb/Fb= 0.29 (1-fa/F'e)= 1.00 (H1-3): fa/Fa + fb/Fb= Check Base Bending 0.31 <= 1 OK Section= W8x18 Sx= 15.20 in^3 Mbase-lateral= 131,120 in -Ib Fy= 50,000 psi Fbx= 0.6*Fy = 30,000 psi fb/Fb= 0.29 OK Page g./' of 2S Str tural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project:Yamamoto Project #: R -070617 - Anchors Configuration: SGL SIDED CANTILEVER RACK Check Load Case 7ASCE 12.4.2.3: : (0.9-0.20*5ds)DL + (0.9-0.20*5ds)Papp + E Overturning Forces Seismic Forces Seismic Ovt Moment=Mseismic= 177,753 in -Ib Rack DL= 303 Ib LLeff=Total LL*0.67=Papp= 1,307 Ib load per upright load per upright Mstabilizing=Mst= [0.71*(303 Ib+1306.5 Ib)]*66 in/2 = 27,885 in- Ib T -seismic= [Mseismic - Mst]/d = 2,271 Ib net seismic uplift Seismic shear= 1,222 Ib/frame Seismic Tension per anchor= 1,135 Ib Seismic Shear per anchor= 305 Ib Check Anchors V w Side Elevation Base depth= 48.0 in Column depth= 18.0 in d= 66.0 in 0.9-0.20*Sds= 0.710 Anchor Type= 0.625 in diam x 4 embed Hilti Kwikbolt TZ Per ICBG ESR 1917 Anchor Inspection Required? Yes # Anchor/base= 4 # Anchor/end= 2 Tallow= 3,014 Ib Vallow= 4,678 Ib Stress Increase= 1 Eqtn Exponent= 1 Page 02,E of 2S Tension/anchr Shear/anchr Tallow Vallow Interactn Eq. Status Seismic 1,135 Ib 305 Ib 3,014 Ib 4,678 Ib 0.442 OK Page 02,E of 2S Strtura) once is 74rngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob S Project: Ya ma Moto Project #: R -070617 - Base to Column Connection Configuration: SGL SIDED CANTILEVER RACK Check Load Case 6b ASCE 12.4.1.3:: (1 +0.10*Sds)D + 0.75L + 0.525E<= 1.0, ASO Method Base to Column Elevation T1= Ft * 2 = 38.80 kip T4= T1 * h4/h1 = 0.00 kip Mstatic= 50 in -kip hl= 6.0 in h2= 4.0 in h3= 2.0 in Bolt Diam= 0.750 in Ft= 19.40 kip (Grade 5 or better) T2= T1 * h2/h1 = 25.87 kip T5= T1 * h5/h1 = 0.00 kip Moment Capacity=Mcap= Tl * hl + T2*h2 + T3*h3 + T4*h4 + T5*h5 + T6*h6 = 362 in -kip • OK Check Longitudinal Brace T3= Ti * h3/h1 = 12.93 kip T6= Tl * h6/h1 = 0.00 kip Mseismic= 131.1 in -kip Meff=Mstatic+Mseismic 168.9 in -kip Mcap= 362.1 in -kip OK Brace Type= X Brace Brace= Strap 2x7ga Area=An= 0.359 in^2 Ft = 0.6 * Fy = 30,000 psi V-Iong= 470 Ib T= 0.525*Vlong*Ldiag/Lh = 396 Ib ft= T/An. = 1,104 psi ft/Ft= 0.04 < 1.0, OK Check Brace Connection Brace Panel Elevation Bay Width=Lh= 48.0 in Brace Panel Ht=Lv= 60.0 in Ldiag= 77.0 in Fy= 50,000 psi Connection= Bolted Fv-bolt= 21,000 psi Bolt Capacity= Bolt Area * Fv-bolt # Bolts= 1 = 4,123 Ib OK Bolt Diam= 0.5 Page a 5 of Str tural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob 5 Project:Yamamoto Project #: R -070617 - Footing Load case: DL+ LL Configuration: SGL SIDED CANTILEVER RACK M Check Puncture d L Thickness=t= 5.0 in Base width=W= 5.25 in fc= 2,500 psi B= 3 f -soil= 750 psf Stress Increase=a= 1.00 base depth=d= 66.0 in phi= 0.65 c= 15.3 in Pgravity= 2,253 Ib Mbase= 50,400 in -Ib Povt= Mbase/(d*0.66) P= 1.4 * (Pgravity + Povt) = 1,157 Ib = 4,774 Ib Fp= [(4/3) + (8/3)/B] * (fc)^0.5 < 2.66 * (fc)^0.5 * a Punct Area=A= (d + t) + (W + t) * 2 * t = 111.1 psi Puncture Stress= (P/A)/Fp = 0.05 OK Check Bending = 812.5 inA2 Areq= P/fsoil = 917 in^2 60.1 in x 15.3 in Mslab= fsoil * c * bA2/(2*144) = 0 in -Ib S= c * t^2/6 63.5 in^3 b= 60.1in-(66 in+2* 5in)>=0 = 0.0 in Fb= 5 * phi * (fc)^0.5 * a fb/Fb= (Mslab/S)/Fb = 162.5 psi = 0.00 OK Str tura) once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: Bob S Project:Yarnamoto Footing Project #: R -070617 - Load case: DL+ LL + Lateral Configuration: SGL SIDED CANTILEVER RACK P M Check Puncture d L Thickness=t= 5.0 in fc= 2,500 psi f -soil= 750 psf base depth=d= 66.0 in Base width=W= 5.25 in B= 3 Stress Increase=a= 1.00 phi= 0.65 c= 15.3 in Pgravity= 1,793 Ib Mbase= 131,120 in -Ib Povt= Mbase/(d*0.66) P= 1.2*Pgravity + Povt = 3,010 Ib = 5,405 Ib Fp= [(4/3) + (8/3)/B] * (fc)^0.5 < 2.66 * (fc)^0.5 * a Punct Area=A= (d + t) + (W + t) * 2 * t = 111.1 psi Puncture Stress= (P/A)/Fp = 0.06 OK Check Bending = 812.5 inA2 Areq= P/fsoil = 1038 in^2 68.0 in x 15.3 in Mslab= fsoil * c * bA2/(2*144) = 0 in -Ib 5= c * t^2/6 63.5 in^3 b= 68 in-(66in+2*sin) >=0 = 0.0 in Fb= 5 * phi * (fc)^0.5 * a fb/Fb= (Mslab/S)/Fb = 162.5 psi = 0.00 OK Page XS of L� Q'ERMITCOORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0192 DATE: 07/17/17 PROJECT NAME: YAMATO TRANSPORT SITE ADDRESS: 18271 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: PrJ kiv& Building Division Public Works ❑ ivy\ AG 1 Fire Prevention Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/18/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 08/15/17 ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) n. REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 ENGINEERED PRODUCTS, A PAO Horne. Espanol Contact Search L&I Page 1 of 2 A -Z Index Ii el.p My LE Safety & Health Claims & Insurance Workplace Rights 0 Washington State Department of Labor & Industries ENGINEERED PRODUCTS, A PAPE CO Owner or tradesperson Principals SALMAN, DAVID EROL, PRESIDENT WETLE, CHRISTOPHER THOMAS, VICE PRESIDENT CARNEAU, CORY SCOTT, VICE PRESIDENT JORGENSEN, LANCE RICHARD, VICE PRESIDENT SMYTHE, SETH LARRY, SECRETARY PAPE, RANDALL JORDAN, SECRETARY CT CORP SYSTEMS, AGENT RIECKE, ROBERT J, SECRETARY (End: 02/04/2013) SAYLOR, THOMAS H, TREASURER (End: 02/04/2013) HOLLINGSHEAD, DANNY W, VICE PRESIDENT (End: 02/12/2013) PAPE, MARY SUSAN, VICE PRESIDENT (End: 02/13/2017) RIECKE, ROBERT JOHN, VICE PRESIDENT (End: 02/13/2017) Doing business as ENGINEERED PRODUCTS, A PAPE CO WA UBI No. 602 684 203 9800 40th AVE SO SEATTLE, WA 98118 206-394-3300 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ENGINPC931C0 Effective — expiration 02/20/2007— 02/20/2019 Bond ............... FIDELITY & DEPOSIT CO OF MD Bond account no. 08748464 $12,000.00 Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602684203&LIC=ENGINPC931 CO&SAW= 8/28/2017 ENGINEERED PRODUCTS, A PAPE CO Received by L&I 02/16/2007 Insurance .............................. National Union Fire Ins of PA Policy no, gI5180113 Effective date 02/13/2007 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date 02/24/2017 03/01/2016 Expiration date 03/01/2018 Insurance history Savings ......................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................................ No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 586,069-04 ................................. Doing business as ENGINEERED PRODUCTS A PAPE COM Estimated workers reported Quarter 2 of Year 2017 "51 to 75 Workers" L&I account contact T2 / DALE RIUTTA (360)902-4834 - Email: RIUD235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 O Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602684203&LIC=ENGINPC931 CO&SAW= 8/28/2017 190' PLAN NORTH Office Sheving DLA\ VIF W NTS FILE COPY Permit V11 O('7- Plan review approv;l is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopte s code or ordinance. Receipt of approved Fiel. op`��d coni] ons is acknowledged: By: Date: City of Tukwila BUILDING DIVISION 44" 192" 96" Ow- REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ..' . al -plan review f es. SEPARciE FE. iQUes _ 13/Mechanical EP/Electrical gPlumbing I2'Gas Piping City of Tukwila BUILDING DIVISION 132" 72" 192" FL - VAT o\ V _W NTS RECEIVED CITY OF TUKWILA .I19�132517 PERMIT CENTER Engineer of Record AU Abclhassani, pg. Structural -Concept F --;ng. Inc_ 23142 Arroyo Vista Rancho Santa Margarita, ,c,4 92688 'ttii DRAWN BY: J.RABAN SCALE: NTS DATE: 3.20.2017 r..XPiRES 7a5/ JUL 1 1 2017 NO: Y3202017 'IEWED FOF CHECKED BY COCOMPLI NI• _ CLING A PROVED SHEET NO. i L 2 7 2017 OF 1 1 Cit of Tukwila BUILuING DIVISION TYP.3/81— COLUMN NOTES: USE @ ALL HANNIBAL COLUMN/BASE LOCATIONS TYP. DESCRIPTION MATERIAL STEEL YIELD DESCRIPTION BASEPLATE:8"x5" 3/8" THICK PLATE DESCRIPTION COLUMN: HMH IF 3014 MATERIAL ASTM A36, Fy=36,000 PSI 1 11/16" 3 -PIN CONNECTOR STEEL YIELD 11 1" 11 14 GAGE THK. DESCRIPTION MATERIAL ASTM A570, Fy=55,000 PSI 3/16V <TYP. 3 3/16" 7/160 GR. 55 RIVET MATERIAL 7 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI TYP. >3/16'V NOTES: USE @ ALL HANNIBAL BEAM TO COLUMN CONNECTION LOCATIONS U.O.N STEEL YIELD DESCRIPTION BRACING: HORIZ. & DIAG. 16 GAGE STEEL ASTM A570, Fy=55,000 PSI MATERIAL NOTES: USE @ ALL HANNIBAL BRACE LOCATIONS . 5" BEAM (HMH#50160) 16 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI NOTES: USE @ TYPE 2 BEAM LOCATIONS. GENERAL INFORMATION HORIZ. BRACE ROW SPACER C OLUMN 1 1 CONNECTOR BASE PLATE NOT A DEPICTION OF THIS PROJECT ,1, 1/2" NOTES: CONFIRM O.A.L. OF ANCHORS WITH INSTALLER TO ENSURE REQUIRED EMBEDMENT IS OBTAINED. DESCRIPTION HILTI KWIKBOLT TZ ANCHOR 3 1/4" MIN. EMBED. SIZE 1/2"0 x 3-1/4" MIN. EMBED. ESR # 1917 F.F. NOTES: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. GENERAL PROJECT NOTES 1. DESIGNED PER REQUIREMENTS OF THE 2015 IBC, ASCE 7-10 & 2012 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss = 1.424, S1 =0.531, Fa = 1.000, Fv = 1.500 Ip = 1.0 (NO PUBLIC ACCESS), Sds = 0.949, Sd1 =0.531, OCCUPANCY CATAG. II SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: TYPE 1= 2500 LBS PER LEVEL TYP. TYPE 2= 3000 LBS PER LEVEL TYP. 4. ANCHORS : HILTI KWIKBOLT TZ ESR#1917, OR POWER SD2 ESR# 2502, AS USED IN CALCULATIONS OR ICC & ENGINEER APPROVED EQUAL. 1/2" 0 x 3-1/4" MIN. EMBEDT. (2) ANCHOR PER BASE PLATE . 5. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 5" x 2500 PSI 7. SOIL BEARING PRESSURE 750 PSF 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER, INSTALL TO SNUG TIGHT FIT OR BETTER 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 12. SHIMS MAY BE USED UNDER THE BASE PLATE TO MAINTAIN THE PLUMBNESS OF THE STORAGE RACK. 13. THE SHIMS SHALL BE MADE OF A MATERIAL THAT MEETS OR EXCEED THE DESIGN BEARING STRENGTH (LRFD) OR ALLOWABLE BEARING STRENGTH (ASD) OF THE FLOOR. 14. THE SHIM SIZE AND LOCATION UNDER THE BASE PLATE SHALL BE EQUAL TO OR GREATER THAN THE REQUIRED BASE PLATE SIZE AND LOCATION. 15. SHIMS SHALL BE INTERLOCKED OR WELDED TOGETHER IN A FASHION THAT CAN TRANSFER ALL THE SHEAR FORCES AT THE BASE. 16. BENDING IN THE ANCHOR ASSOCIATED WITH SHIMS OR GROUT UNDER THE BASE PLATE SHALL BE CONSIDERED IN THE DESIGN OF THE ANCHOR BOLTS. 1" 3 3/8" 4 PLCS NOTES: USE (2) STD ROW SPACERS FOR DOUBLE ROW DESCRIPTION STD ROW SPACER MATERIAL 16 GAGE STEEL YIELD ASTM A570, Fy =55,000 PSI NOTES: ATTACH WITH (4) 1/2"0 GR. 5 BOLTS, (2) @ EACH END 1 11/16" 5/160 SAFETY PIN /160 GR. 55 RIVET DESCRIPTION 4 -PIN CONNECTOR MATERIAL 7 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI NOTES: USE @ TYPE 1 LVL 1 BEAM TO COLUMN CONNECTION LOCATIONS. DESCRIPTION 3-3/8" BEAM (HMH#33160) MATERIAL 16 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI NOTES: USE @ TYPE 1 BEAM LOCATIONS. 192" 58" 60" 7 I I TYPE 1 SELECTIVE RACK TYPE 2 SELECTIVE RACK 96" 192" 60" 72" 144" 192" 48" 3 it CFI E z 0 in Ix W tr 0 0 < N REVIDOR C ODE COMPLIANCE APPROVED co co T co F— JUL 2 7 2017 City of Tukwila RECEIVED DJILDING DIVISION OF iUKWIL JUL 13 2017 RMIT CENTER Y,fi t)5.,: t, 41. , FRONT VIEW FRONT VIEW SIDE VIEW Exp s � e 4 .e N 0 1` z )0/3 NO, DESCRIPTION STORAGE RACK ELEVATIONS R-070617-11 LV SHEET N0. SCE 1 OF 2 JUL 117017 �� NOT A DEPICTION OF THIS PROJECT 5 1/T-1 8 1/8" COLUMN W8"X 18# 48" SGL SIDED W8" X 18# COLUM VARIES 4 4 5 1 /8"X8 1 /8" 3/16" THK. PLATE 13/16'0 FOR 3/4'0 GR8 BOLT (6) PER BASE TO COLUMN 7 G►GE 2-1j2" 3/16" -2-1 /2"" O 0 O 0 O 0 O 0 0' 16" THK. NOTES: USE @ TYPE SGL SIDED STRUCTURAL BASE TO COLUMN LOCATIONS. ATTACH W/ 3/4"0 GR 5 BOLTS COLUMN TO BASE. HORIZ. & DIAG. BRACE MEMBER NOTES: ATTACH BRACING TO COLUMN WITH 1/2"0 BOLTS, GR. 5 OR BETTER. DESCRIPTION MATERIAL BASE: STRUCTURAL W8" X 18# DESCRIPTION MATERIAL COLUMN: STRUCTURAL W8" X 18# DESCRIPTION MATERIAL HORIZ. BRACE L2-1/2" X 2-1/2" X 3/16" DESCRIPTION MATERIAL DIAG. BRACE 2" X 7 GA STRAP STEEL YIELD ASTM A572, Fy=50,000 PSI SECTION A -A „ STEEL YIELD 48" ASTM A572, Fy=50,000 PSI TOP VIEW 3"x 5.7# STRUCT. I -BEA 2 DEGREE PITCH 1 1/2" 71 /2" A NOTES: ALL LOADS TO BE EVENLY DISTRIBUTED OVER ALL ARMS. NO TIP LOADING ALLOWED. SIDE VIEW DESCRIPTION 3" STRUCTURAL ARM MATERIAL S3" X 5.7# STEEL YIELD ASTM A572, Fy=50,000 PSI NOTES: ATTACH W/ (4) 3/4" DIA. GR. 5 BOLTS. STEEL YIELD ASTM A36, Fy=36,000 PSI STEEL YIELD 2"x2.5"x1/4" TAB 1 /2"0 GR. 5 Hardware 2" x 7 GA STRAP ASTM A36, Fy=36,000 PSI OLUMN -1/2" X 2-1/2' X 3/16" 60" DESCRIPTION BRACE TO COLUMN CONNECTION O. BASE PLATE F.F. .L. /84 NOTES: CONFIRM O.A.L. OF ANCHORS WITH INSTALLER TO ENSURE REQUIRED EMBEDMENT IS OBTAINED. DESCRIPTION HILTI KWIKBOLT TZ ANCHOR 5/8"0 x 4" MIN. EMBED. 4" IN. EMBED. 5/8" SINGLE SIDED (4) ANCHOR PER BASEPLATE. rn L_J L.,J DEFINITION OF COMPONENTS: STRUCTURAL CANTILEVER 192" GENERAL PROJECT NOTES 1. DESIGNED PER REQUIREMENTS OF THE 2015 IBC, ASCE 7-10 AND THE 2012 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss =1.424, S1 = 0.531, Fa = 1.000, Fv = 1.500, Ip = 1.0 (NO PUBLIC ACCESS), Sds = 0.949, Sd1 = 0.531, OCC. CATAG. II, SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: TYPE SGL SIDED CANTILEVER = 650# PER ARM LEVEL 4. ANCHORS: HILTI KWIK BOLT TZ ESR #1917 OR POWER SD2 #2502 5/8"0 X 4" MIN. EMBED (4) ANCHOR PER BASE, (2) @ TOE & HEEL. 5. SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 5" X 2500 PSI 7. SOIL BEARING PRESSURE 750 PSF 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER. INSTALL TO SNUG TIGHT FIT OR BETTER 10. SPECIAL INSPECTION IS REQUIRED FOR ALL STRUCTURAL WELDS EXCEPT FOR WELDING DONE IN AN APPROVED FABRICATOR'S SHOP AND SINGLE -PASS FILLET WELDS NOT EXCEEDING 5/16 INCH IN SIZE. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 12. SHIMS MAY BE USED UNDER THE BASE PLATE TO MAINTAIN THE PLUMBNESS OF THE STORAGE RACK. 13. THE SHIMS SHALL BE MADE OF A MATERIAL THAT MEETS OR EXCEED THE DESIGN BEARING STRENGTH (LRFD) OR ALLOWABLE BEARING STRENGTH (ASD) OF THE FLOOR. 14. THE SHIM SIZE AND LOCATION UNDER THE BASE PLATE SHALL BE EQUAL TO OR GREATER THAN THE REQUIRED BASE PLATE SIZE AND LOCATION. 15. SHIMS SHALL BE INTERLOCKED OR WELDED TOGETHER IN A FASHION THAT CAN TRANSFER ALL THE SHEAR FORCES AT THE BASE. 16. BENDING IN THE ANCHOR ASSOCIATED WITH SHIMS OR GROUT UNDER THE BASE PLATE SHALL BE CONSIDERED IN THE DESIGN OF THE ANCHOR BOLTS. TYPE SINGLE SIDED CANTILEVER RACK 48" 52" 72" 12" 3 11 24" 48" k k 48" c.c. SIDE VIEW FRONT VIEW W cts RECF CITY OF AIL PERMIT REVIEWED FOR CODE COMPLIANCE APPROVED R-070617-11 LV SHEET No. 1917 NOTE: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. JUL 272017 DESCRIPTION ANCHOR PLAN NOTE: CANTILEVER RACK ELEVATIONS