Loading...
HomeMy WebLinkAboutPermit D17-0194 - AMERICA'S BEST CONTACTS AND EYEGLASSES - INTERIOR REMODELAMERICA'S BEST CONTACT AND EYEGLASSES 17334 SOUTHCENTER PKWY D77-0194 Parcel No: Address: Project Name: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049110 Permit Number: 17334 SOUTHCENTER PKWY Issue Date: Permit Expires On: AMERICA'S BET CONTACT AND EYEGLASSES D17-0194 9/25/2017 3/24/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: KIR TUKWILA 050 LLC 3333 NEW HYDE PARK RD #100 C/O KIMCO REALTY CORP, PO BOX 5020 NEW HYDE PK, IL, 11042 MATT MURRAY 111 W WASHINGTON ST, STE 450, CHICAGO, IL, 60602 HORIZON RETAIL CONSTRUCTION INC 1500 HORIZON DR , STURTEVANT, WI, 53177 HORIZRC072N5 Lender: Name: MATT MURRAY Address: 111 W WASHINGTON ST, STE 450, CHICAGO, IL, 60602 Phone: (312) 296-1577 Phone: (262) 638-6000 Expiration Date: 4/15/2019 DESCRIPTION OF WORK: INTERIOR REMODEL ONLY. NEW FINISHES, INTERIOR PARTITIONS, ELECTRICAL AND LIGHTING TO ACCOMMODATE NEW LAYOUT. NO WORK TO EXTERIOR SHELL. Project Valuation: $184,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $3,936.74 Occupancy per IBC: M Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0. Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: f --)-s---17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: w�- -I e4- G31 It ar5� Date: (�5 17 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. o c� 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or' brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 0 0 24: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 30: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 33: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 37: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL • 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. )fl' O 1 Project No. Date Application Accepted: 1 k'1 iN% Date Application Expires: I I ` D (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 17334 Southcenter Pkwy. Tukwila, WA 98188 Tenant Name: America's Best Contact and Eyeglasses PROPERTY OWNER Name: `cirt\,CO Rea lj (.kc w ems, z.cw.Ke() Address: Ho 6 5 C ; a SCtvcre ititall SE City: i3e11evn� State: VJh Zip: g 066 CONTACT PERSON — person receiving all project communication Name: Matt Murray Address: 111 W. Washington St. City: Chicago State: IL Zip: 60602 Phone: (312) 296-1577 Fax: (312) 277-1034 Email: mmurray@burnhamnationwide.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name:SGhngttel En.zrt ears( ncp Company Name: (awCet,ce, Grove Engineer Name: Greo t- Sc;hnraf r , Address: Architect Name: Day 1 d 6 6 izo +.e y e( , City: State: Zip: Phone: Fax: Phone: l y_ a-. i- Si Fax: 30 4_ 2 i— Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\20I I Applications\Permit Application Revised - 8-9-I I.does Revised: August 2011 bh Suite Number: N/A Floor: 1 New Tenant: ❑ Yes e „No ARCHITECT OF RECORD Company Name:SGhngttel En.zrt ears( ncp Company Name: (awCet,ce, Grove Engineer Name: Greo t- Sc;hnraf r , Addressp \t,44 ` \V Architect Name: Day 1 d 6 6 izo +.e y e( City: oMGh6‘, State: Zip:6 Address: 31 q (\l F6u (-44. S{�e.e. -. £ /boo City: L(3v v9 State: MO Ztp.G, 0 a Phone: l y_ a-. i- Si Fax: 30 4_ 2 i— Email: ENGINEER OF RECORD Company Name:SGhngttel En.zrt ears( ncp Engineer Name: Greo t- Sc;hnraf r , Addressp \t,44 ` \V Address: (�55 5. ..-..-1,2„d c,„tee . City: oMGh6‘, State: Zip:6 la 1 Phone: 4®2_ 6� 1 _ l68ax: Email: MktlgoCe a 60wAt6ei. cow•. LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) .orrA \Name.` L tiai"1 Addressp \t,44 ` \V A.151 nV�S City: Won te: 11” Zip: U J Page 1 of 4 iaLDING PERMIT INFORMATI(``� 206-431-3670 Valuation of Project (contractor's bid price): $ Describe the scope of work (please provide detailed information): Existing Building Valuation: $ i'48.'1 1"t12-1°0- 21°x, P -.1.1,01216L dt4L4 I-4IS1-46ul-1 rE ,04. PANTIT? DI -15, 1 re-' -PL ?c 64 (.l 4#1i jj 1 kcce.-o}-tri o Are Nv Lobo.. —ro o e -71-1e2-1, . 1`1-rs- -4-4ez_,M le -AL NI r--)012_ ALT Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq. ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1S` Floor 31664 3 9 t (• lc) l A to / /4 IIB PI 2nd Floor t 3rd Floor ._—. Floors thru _.. Basement r– Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq. ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System – For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 [iki?LIC WORKS PERMIT INF NATION — 206-433-0179 0 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Tukwila ❑ ...Water District #I25 ❑ ...Water Availability Provided Sewer District '..Tukwila 0 ...Sewer Use Certificate ❑ .. Highline 1=1 ... Valley View ❑ .. Renton ❑... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public WO # WO # WO # Private ❑ Private 0 ❑ .. Grease interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applicat ions \Forms -Applications On Line \20I 1 Applications \Permit Application Revised - 8-9-I I.does Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AUTH IZED AGENT: Signature: Print Name: Matt Murray Mailing Address: 111 W. Washington St. Date: 07/11/2017 Day Telephone: (312) 296-1577 Chicago IL 60602 H\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.does Revised: August 2011 bh City State Zip Page 4 of 4 wI1LA —_ fry qsy -1 "ei Cash Register Receipt City of Tukwila Receipt Number R12410 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK . $2,754.54 D17-0194 Address: 17334 SOUTHCENTER PKWY Apn: 2623049110 $2,507.99; Credit Card Fee $73.05 Credit Card Fee R000.369.908.00.00 0.00 $73.05 DEVELOPMENT $2,321.43 PERMIT FEE R000.322.100.00.00 0.00 $2,270.11 PLAN CHECK FEE R000.345.830.00.00 0.00 $46.82 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $113.51 TECHNOLOGY FEE R000.322.900.04.00 0.00 $113.51 'PG17-0089. Address:17334 SOUTHCENTER PKWY Apn: 2623049110 $246.55. Credit Card Fee • $7.18 Credit Card Fee R000.369.908.00.00 0.00 $7.18 PLUMBING $227:97 PERMIT FEE R000.322.100.00.00 0.00 $194.82 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $11.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12410 R000.322.900.04.00 0.00 $11.40 $2,754.54 Date Paid: Monday, September 25, 2017 Paid By: JUSTIN THOMPSON Pay Method: CREDIT CARD 058965 Printed: Monday, September 25, 2017 10:36 AM 1 of 1 CIIIIAWSYSTEMS • Cash Register Receipt City of Tukwila •Receipt Number R11911 • DESCRIPTIONS ACCOUNT PermitTRAK , , QUANTITY . , Z -N PAID $1,549.35 D17-0194 Address: 17334 SOUTHCENTER PKWY Apn 2623049110 $1,428.75 DEVELOPMENT • $1,428.75 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,428.75 M17-0102 Address: 17334 SOUTHCENTER PKWY Apn 2623049110 $63.61 MECHANICAL $63.61 • PLAN CHECK FEE R000.322.102.00.00 0.00 $63.61 PG17-0089 Address: 17334 SOUTHCENTER PKWY Apn: 2623049110 $56.99 PLUMBING $56.99 •PLAN CHECK FEE•R000.322.103.00.00 . • , TOTAL FEES PAID BY RECEIPT: R11911 0.00 '';'.. $56.99 $1,549.35 Date Paid: Friday, July 14, 2017 Paid By: BURNHAM NATIONWIDE Pay Method: CHECK 23330 Printed: Friday, July 14, 2017 10:11 AM 1 of 1 nWSYSTEMS • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36700/ Permit Inspection Request Line (206) 438-9350 Project: Asti reicAsBo— eofrmas Type of Inspection: goa_9l/6- AN* — Address: /73 5 ? k,ER /kw) Date Called: Special Instructions: fi gs gm AlNG i! - Date Wanted: a.m. l 2 -12 - ! 7 CP.m� Requester: J f rr Phone No: l '2 la Z -' 1 - 1A3/0 5/ STAR( MNQq:.Cfhti4RL,S Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c*- 801D/A16- L Inspector: Date: /212 `/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DI7-0191 Project: A-Mclew/ &S7 2 7) Peye:co Type of Inspection: - 0 Sd5Pip/Deb e /C.lW Address: /733V S©OT r /C4, Date Called: Special Instructions: Date Wanted:R3., /p / "j7 p.m. Requester: Phone No: MApproved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date: -/(0`i? REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1 /1/niA1 C�arA£TI € Type of Inspection: fi'ti11/l & Address: a,,- /733 sov ite4x'/ //li 9 Date Called: Special Instructions: Date Wanted: /4!)--/0 — / 7 a.m. p.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 1`rn/k/C-. Date: �6—/Ci —/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 014-0 14 - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: (Type Mint:Y/4 (.4-S ee--"--Firt--(4/42.sti-4., of Inspection:I Addres: Suite #: Fire Alarm:/&4 Contact Person: Special Instructions: Monitor: Phone No.: K Approved perapplicable codes. Corrections required prior to approval. COMMENTS: �.t 4 ' b (rsin itai- 17) 74-60•i r Needs Shift Inspection: ` :Sprinklers: \t - Fire Alarm:/&4 _ ' Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • Inspector: litm c.4- Date: /On i iq.— Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /.7- - Z/y. DI 7 - ��/.Y. PERMIT NUMBERS CITY OF TUKWILAFIRE DEPARTMENT 206-57$-4407 Project: / ta (Type of Inspection: Address: Suite #: /7331 &Go/ Contac`f Person: Special Instructions: / `Phone No.: t [Approved per applicable codes. Corrections required prior to approval. f COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 74? .ACL"` ,P,47--e---r i ,. %P/GfG_r caar7 I r 2- 44d/ 5 - ,rr c , -'v- (.4„, — /4 6 S Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:— /0/53 Date: /17// / Hrs.: ,X4,./.....A.,,. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection: Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /7--s —/6/ — 0/94' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: /Type of Inspection: Address: Suite #: ) -?3 3 (i ,/Contact SC P 1&1&JN Person: , ... Pr Iia ► 1 Le_r-. -1,.. Special Instructions: , - Phone No.: (7-4 2) 3,3/ ---oho Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: '. Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ^...— '4-2E-- 0i4,e4n-Rv.r...,r. 2 Vs'?----- l/I4(-�T /„s4/ �� , Ig'tsLr'8'c. .(VI , /14 014 /,/ /9 Paivr% /N 1.74,,,ziy f.11 , 4-) lie-- , // A”. /. -- / / / Needs Shift Inspection: Sprinklers: Fire Alarm: '. Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: - Date: Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of.TUkwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type .e1v1C. S,�esi- 6i.e. G1( of Inspection: se s Addres: Suite #: 33 , 4 S _.. PICIA70 Contact Person: Special Instructions: Ok_ 70 V - /Phone No.: r Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: , Occupancy Type: Permits: Ok_ 70 C"P/ /e)e-- 0 z- ✓If/ C_P/{(--61--5 - pia.-- v \ , FZ D (E77- FYI/ Vii► S^` 1 ix‘i gid; k.sl Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: , Occupancy Type: Permits: Inspector: f77 s-4_ Date: i.,67:)/( 9— Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc bMcMaVl 1/14 i4 n IAAYCS},r 3/14/14 l env T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /7 -S — /9/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 s Project:�j // algli- 3LSF %e6s�.r Type of Inspection:� SIJIIr -(el Address: Suite #: 1733'7 CC fi '1 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , reitz / a C.,,,-,ef-- P A Ase -4- _f___ ^"�7 / V e- I --k C ry — Ct ( Y At? P 1. . (n) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: d Date: /007 Hrs.: /_ 0 f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from .. the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company. Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Project Summary PROJ-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 General Info Project Title: America's Best Contacts and Eyeglasses Date • 6/27/2017 This PROJ-SUM Project Street Address: 17334 Southcenter Pkwy For Building Department { Use ,:.,— form shall be provided as a cover Project City, County, Zip: Tukwila, WA 98188 sheet for all5 compliance form Project Owner or Rep: Vincent, Amber submittals. Project Title matches project Jurisdiction: plans title block. Project Description Select all that apply to the scope of project. Select Addition + Existing or Alteration + Existing if the existing building will be combined with the addition or alteration to demonstrate compliance per Section C502.1 or C503.1. New Existing Building ❑ " ❑ ❑ Construction and Additions New Building Building Retrofit Alteration Change of Occupancy Elements Scope - Select all that All Service Hot Water Systems ❑ ❑ ❑ apply ❑ ,' Building Addition ❑ Alteration + Existing ❑ Historic Building • Building Envelope ❑ Lighting Systems a Addition + Existing Change in Space Conditioning Mechanical Systems Electrical Systems Occupancy Type P y yP All Commercial Q Group R - R2, R3, & R4 Q over 3 stories and all R1 Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R occupancies. Mixed Occupancy - Building is three stories or less above grade and it has both Commerical and Group R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Select all that apply to the scope of project Space Conditioning❑ p Fully Conditioned ❑ Semi-heated2 Low Energy Space Category3 ■ CeGO rgg[ MAEPRJ yIANCE APPPOVED Categories Eligible Low Energy Spaces ❑ Unconditioned ❑ Wireless service equipment shelter ❑ • Low energy heating/cooling c. Greenhouse4 pacity •iJUL 2 6 2017 '❑ Equipment building Floors Above Floor Area and Grade Building Gross Conditioned Floor Arearrcimrnditipned,F8i61r�a C6.y of T ukwwf is V VVttVV Stories 1 4,024 4024.0 Q Prescriptive C Total Building Performance Prescriptive - Projects complying prescriptively shall demonstrate compliance with all applicable mandatory and prescriptve requirements of this code. Refer to C401.2, Item 1 for more information. Compliance forms General Compliance to include with a Prescriptive submittal: All applicable ENV, LTG, MECH and C406. Path Total Building Performance - Projects complying via total building performance (TBP) shall include a summary of results from a whole building energy model per Section C407 and shall demonstrate compliance with all applicable mandatory provisions in this Code. Refer to Section C401.2, Item 2 for more information. Compliance forms to include with a TPB submital: PROJ-SUM, C406 -SUM & C406 -DETAIL, ENV -CHK, LTG - EXT, LTG -CHK, and all MECH forms (except MECH-ECONO). CITY OF TUKWILA JUL 14 2017 PERMIT CENTER Dii- OId1L- Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Auoust 2016 Project Info Compliance forms do not require a, password to use. Instructional and calculating cells are write - protected. Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 Applicant Information. Provide contact information for individual vnhocan respond to inquiries about compliance form information provided. For Building Department Use Company Name: Lawrence Group Company Address: 319 N. Fourth Street, St. Louis, MO 63102 Applicant Name: Vincent, Amber Applicant Phone: 314-231-5700 Applicant Email: amber.fouts@cushwake.com Project Description • New Building ■ Addition tr, Alteration ■ Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions Referto Section C502.2.6 for additional requirements. Compliance Method Interior lighting I Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project -............................................................................_.._..........._..-................................................................................................................................................_.............................................................................................._......._. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing interior Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE For exterior lighting projects, include new + existing exterior Tradable and Proposed Non -Tradable Lighting Wattage tables t . • in Proposed in Proposed lighting fixture wattage form. lighting fixture wattage in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power Control elements that of the retrofit project. combination of spaces 50% of the existing fixtures in some spaces, and fixtures are replaced in provide separate lighting compliance forms for conditions. Spaces undergoing type of retrofit may be lighting power compliance Refer to Section C503.6 requirements. All alteration lighting controls commissioned perC408.3.fixtures and Lighting applyto the scope If project includes a where less than are replaced 50% orinore of the others, then power the two retrofit the same combined into one form. for additional shall be being made to lighting space are:rio(1 4.1 ...11 'Ir �` lo, IT =10 v Lighting Power Interior lighting ! Parking garage 1 Exterior lighting 50% or more of existing are replaced I ■ ■ i Less than 50% of existing are replacedl ■ ■ ■ I I Lamp and/or ballast replacement only -1 _ - existing total wattage not increased M I II ----------------------------J--- _ __-__ -------------I----------- 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls i Interior lighting i__._._ Parking garage Exterior lighting .._.___.-._ _ _.__ _.__ i -------7---7— —_.._______.. __.__._.____.__._ ._.._._____..-..._._tw_.___.__._.________ New wiring installed to serve added I and/or fixtures relocated to Ir j ■ ■ new circuit(s) l New or moved lighting panel 1 t* ■ ■ i _.._.._.................................................._................................................_.................._........... manual controls per controls per C405.2.4 provide required controls as noted for New controls that apply to do not applto C405.2.3, and application per C405.2.7. Wiring and automatic a new interior reconfigured Interior space is reconfigured - • luminaires unchanged or relocated .................._.._.._.._.._......_.._.._.._.._.._._.._ New wiring or circuit - For interior lighting, provide required occupancy sensor controls per C405.2.1, daylight responsive specific lighting controls per C405.2.5. For exterior lighting, New or moved panel - Provide all applicable lighting controls time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting space. Application specific lighting control provisions per C405.2.5 j., No changes are •the interior or exterior systems and existing uses and configuration ed.A 11111)11 Change of Space Use P € Ji n :� I-1 o- -41 11 ,V change in space use are upgraded to or C405.4.2(2). Code in Proposed Lighting Wattage • Existing interior lighting systems in areas under -going a comply with LPAs for the new space types per Tables C405.4.2(1) Identify interior spaces requiring LPD upgrade to the current table in LTG -INT -BLD or LTG -INT -SPACE form. -;..-t Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 Interior Lighting System Description t Interior Lighting Power Allowance Method ■ Building Area Method n Space -by -space Method Select method used in project. Interior Lighting Controls tr All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting poorer shall comply Kith required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dKelling units comply Kith: • OC405.2 thru C405.5 Commercial Lighting Controls and LPA 0C406.3 High Efficacy Lighting 0 Exterior Lighting System Description Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 Calculation NOTE 9 Area 0 0 Addition - O Addition stand alone + existing eh, Spaces where < 50% of . Spaces where z 50% of e luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type • Standard • G Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage""" 14 Location (plan #, room #) Space Type Ceiling z Height Gross Interior Area in ft' Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 101 - Display Sales area 10 1737 1.270 2206 103 -Consult, Pre- Consult Health care facility: Exam/treatment 10 588 1 .330 782 105 - Passage Corridor: all other 10 46 0 .530 24 106 -Women's, Men's Restrooms Restroom: all other 10 153 0 .780 119 108 - Breakroom Lounge/breakroom: all other 10 158 0.580 92 109 - Waiting Lobby: all other 10 706 0.720 508 110 - Manager's Office 114 - Office Office: Enclosed 10 272 0.908 247 113 - Supply 115 - Supply 117 - Mop Storage room 10 245 0 .500 123 116 - Mechanical Electrical/mechanical 10 119 0.760 90 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAIlPTE a Total Area Retail Display 4024 LTG-INT-DISP Allowed Watt 2 Allowance from 1620 117 - Mop D1 - Down Light, (1) 32w CFL, Electronic Ballast 5812 Proposed Lighting WattagENOTE< Location (plan #, room #) Fixture DescriptionNOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed 101 - Display A - 2'x4' Troffer, (1) 46w LED 14 46 644 101 - Display E - 4' Strip Light, (2) F32T8, Electronic Ballast 5 57 285 101 - Display D1 - Down Light, (1) 32w CFL, Electronic Ballast 3 38 114 103 -Consult, Pre -A Consult - 2'x4' Troffer, (1) 46w LED 8 46 368 103 -Consult, Pre - Consult D - Down Light, (1) 150w Incandescent 6 150 900 105 - Passage A -.2'x4' Troffer, (1) 46w LED 1 46 46 106 -Women's, Men's Restrooms A - 2'x4' Troffer, (1) 46w LED 2 46 92 108 - Breakroom A - 2'x4' Troffer, (1) 46w LED 2 46 92 109 - Waiting A - 2'x4' Troffer, (1) 46w LED 10 46 460 109 - Waiting B - 2'x2' Troffer, (1) 35w LED 1 35 • 35 110 -Manager's Office A - 2'x4' Troffer, (1) 46w LED 2 46 92 114 - Office A - 2'x4' Troffer, (1) 46w LED 2 46 92 113 - Supply A - 2'x4' Troffer, (1) 46w LED 2 46 92 115 - Supply A - 2'x4' Troffer, (1) 46w LED 2 46 92 117 - Mop D1 - Down Light, (1) 32w CFL, Electronic Ballast 2 38 76 116 - Mechanical A - 2'x4' Troffer, (1) 46w LED 2 46 92 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1620 5192 Interior Lighting Power AllowancE COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). c,.. track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stones and all R1 Revised Auoust 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 General Note - In Sales areas, an increase in lighting power allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible merchanise display lighting may be included in the Gross Interior Area under each Retail category. This lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use Location (plan #, room #) Retail Sales Area Type"OTE 1 Gross Interior Area imft2 Allowed Watts per ft' NOTE 2 Watts Allowed (watts/ftz x area) 101 - Display Retail 3: Furniture, clothing, cosmetics, artwork 1737 1.40 2432 Total Retail With Display Area Maximum 1737 Total Watts Base Allowand Allowance OTE 3 2432 Retail Display Lighting Retail Display 500 2 932 Proposed Retail Display Lighting Wattage "TE' Retail Area Location (plan #, room #) Fixture Description NOTE 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Retail 3 101 - Display TRACK - 30w per Linear Foot 54 3 0 162 0 RETAIL DISPLAY WATTAGE ALLOWANCE - AS PROPOSED Proposed Retail Display Lighting Totals from LTG -INT -DISPLAY Total Retail Proposed Display Watts"OTE 7 Retail Display Power Allowance"OTE 8 1620 1620 Retail 1 Retail 2 Retail 3 Retail 4 1620 Note 1 - Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.2.2.1 maybe entered in this table. Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11. Note 3 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 4 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 5 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 7 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG -INT -SPACE. Note 8 - Retail display lighting power allowance is the lesser of the Maximum Retail DisplayAllowence OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG -INT -SPACE. Note 9 - Enter a unique title for each lobby area in project that has art/exhibit display lighting. Note 10 - Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c = 0.5 W/ft2. Note 11 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage For Interior D .p!ay Lighting - Space,,.by-.Space 20 LTS=!NT..DISPLAY ate Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stones and all R1 eneral area hohtino. may be entered in this table. Revised July 2016 Pr6Ot frithrkobby g( iltlrs tattiii cgiriagiggyentered in LTG -INT -SPACE. Date 6/27/2017 General Note - In Lobby areas, an additional wattage allowance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting may use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allowance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NOTE 9 Lobby Description including (plan # & room #) Gross Interior Area in ft2 Maximum Display Watts Allowed Per Area NOTE 10 Proposed Display Lighting Total Per Area NOTE 11 Total Lobby with Display Are4 Total Lobby Art/Exhibit Display Allowanc@ OTE 13 Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE' Lobby Area Location (plan #, room #) Fixture Description NOTE 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Total Lobby Art/Exhibit Proposed Display Watt ey Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stones and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken El, E3 Yes C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters El, E3 NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves El, E3 Yes C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls El, E3 Yea C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; El, E3 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies El, E3 Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; El, E3 Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception El, E3 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% Yes C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used El, E3 Yes C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. • El, E3 Yes C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; El, E3 Indicate toplight daylight zone areas on plans, include sq. ft.; El, E3 For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) El, E3 NA C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section Yes C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; El, E3 Indicate manual and automatic lighting control method El, E3 Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NAcontrol C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy for supplemental task lighting, including under -shelf or under -cabinet lighting NAindependently C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; El, E3 Provide calculation of lighting power density of total egress lighting; El, E3 If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control El, E3 NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 , NA C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% NA C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Yeeper C405.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; El, E3 Identify applicable commissioning documentation requirements Section C408 or eligibility for exception; El, E3 Provide written procedures for functional testing of all automatic controls and describe the expected system response El, E3 Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; El, E3 Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; El, E3 Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; El, E3 Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently El, E3 Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) El, E3 NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yes C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations ofE1, space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable E3 NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space • Method EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exceptior applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: America's Best Contacts and Eyeglasses Date 6/27/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter NA C405.6 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more . NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use NA 0405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; El, E3 Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control El, E3 If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist CPERMIT COORD COPY. d" PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0194 DATE: 07/17/17 PROJECT NAME: AMERICA'S BEST CONTACT & EYEGLASSES SITE ADDRESS: 17334 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: f� WI lir Building Division 10- Public Works Fire reve l"i"on Structural 1 Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/18/17 Structural Review Required REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: Approved DUE DATE: 08/15/17 ❑ Approved with Conditions Corrections Required n Denied (correctio s entered in Reviews) `(ie: Zoning Issues) Notatin ', 10)1) WV/KV-6 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 HORIZON RETAIL CONST INC 0 0 Washington State Department of Labor 8c Industries C Home Espanol Contact Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z Index Workplace Rights • HORIZON RETAIL CONST INC Owner or tradesperson Principals HENDERSEN, JON E GUSTIN, ROBERT L HENDERSON, JON E JAWORT, DAN, AGENT Doing business as HORIZON RETAIL CONST INC WA UBI No. 601 483 044 1500 HORIZON DRIVE STURTEVANT, WI 53177 262-638-6000 Business type Corporation Governing persons ROBERT L GUSTIN JON E HENDERSEN; PATRICK J CHRISTENSEN; PAT CHRISTENSON; JON E HENDERSEN; ERIC NIEDEFFER; TOM SCHAEFER; DAN SIUDAK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HORIZRC072N5 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601483044&LIC=HORIZRC072N5&SAW= 9/25/2017 HORIZON RETAIL CONST INC Effective — expiration 08/25/1993— 04/15/2019 Bond HANOVER INS CO Bond account no. 1592447 $12,000.00 Received by L&I Effective date 04/15/2002 04/10/2002 Expiration date Until Canceled Insurance Zurich American Ins Co Policy no. 5919211 $1,000,000.00 Received by L&I Effective date 02/23/2017 03/29/2017 Expiration date 03/29/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 3 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 861,958-00 Account is current. Doing business as HORIZON RETAIL CONSTRUCTION Estimated workers reported Quarter 2 of Year 2017 "4 to 6 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes This contractor received a valid strike(s) for violation or infraction for the following L&I law(s). Learn more about contractor strikes. ROW Violation Effective Date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601483044&LIC=HORIZRC072N5&SAW= 9/25/2017 rn -a C col rn N 0t 0 0) rl c C a) E 0 0 0 Q) r C .0) to0) 0) N (Li 6,23/2017 3:09:21 PM Q PROJECT: ■ u a, Parkway Super Center, 17334 Southcenter Pkwy, Tukwila, WA 98188 8 a1' merica'ses n LANDLORD REQUIRED SUBCONTRACTORS: Trade None DIVISION OF WORK DIVISION LLD GC SCOPE OF WORK TENANT GC SCOPE OF WORK EXISTING REMARKS LANDLORD TENANT CONTRACTOR LANDLORD TENANT LCONTRACTOR GENERAL REQUIREMENTS DIVISION LLD GC SCOPE OF WORK TENANT GC SCOPE OF WORK EXISTING REMARKS LANDLORD TENANT CONTRACTOR 1. PERMITS & FEES TENANT CONTRACTOR 0 0 G.C. TO PAY BALANCE 2. INSPECTIONS 0 3. TEMPORARY HEAT 4. TEMPORARY ELECTRIC 0 0 5. TEMPORARY ENCLOSURE 0 0 GRAB BARS BY G.C. 6. CONSTRUCTION BARRICADE O 7. PROFESSIONAL CLEANUP 0 11 - SPECIALTIES O AS NOTED 102 - SITE WORK 1. DEMOLITION 0 2. SAW CUTTING OF SLAB 0 3. ROOF PENETRATIONS 0 0 HOME DEPOT ITEMS BY G.C. INSTALLED BY FIXTURE CO. 0 0 0 3. CASH REGISTERS 03 - CONCRETE SLAB O O 0 1. CONCRETE SLAB 0 EXISTING, P+R 04 - MASONRY O NEW UNITS 1. BRICK A. DIFFUSERS 0 2. CONCRETE BLOCK B. RETURNS 0 C. INT. DISTRIBUTION NETWORK 0 05 - METALS D. FINAL HVAC CHECK & BALANCE O 1. METAL STUDS E. INSPECT & SERVICE 0 0 A. DEMISING WALL 2. TEMPERATURE CONTROL 0 3. EXHAUST FANS 0 0 EXISTING, P+R 1) GYP. BD O 4. PLUMBING 0 B. INTERIOR PARTITIONS & SOFFITS 0 A. TOILET ROOM 0 C. STOREFRONT MODIFICATIONS 0 1)WASTE WATER & VENT 0 REMOVE FORMER TENANT'S SIGNAGE, REPAIR & PAINT STOREFRONT AND SIGNBAND READY FOR NEW SIGNAGE 2. STANDARDS O 0 INSTALL NEW 2) FIXTURES 0 O _ 3. MISCELANEOUS 0 6. SPRINKLER SYSTEM 0 0 RELOCATE HEADS AS REQUIRED 06 -CARPENTRY 0 0 NEW NEW 1. WOOD FRAMING 9. OTHER SINKS O A. BLOCKING EXAM ROOMS (2), BREAK AREA CONTACT LENS AREA O 0 0 B. ROUGH CARPENTRY 16 - ELECTRICAL 1. VOLTAGE AND PHASE 0 O 2. FINISH CARPENTRY A. UPGRADE 0 0 2. SUB PANEL 0 0 07 - MOISTURE CQNTROL A. SIGN J -BOX O B. SIGN TIMECLOCK 08 - DOORS ' 0 3. SMOKE EXHAUST SYSTEM 1. STOREFRONT ' O IF REQUIRED 0 0 2. INTERIOR DOQRS O IF REQUIRED 0 A. HARDWARE ' 0 IF REQUIRED O 3. REAR EXIT DQOR 0 0 0 UPGRADE ALARMED HARDWARE 0 A. LIGHTS 09 - FINISHES 0 ORDER FROM CAPITOL LIGHT 1)2X4 & 2X2 FLUOR. 1. FLOORS O A. TILE VINYL 2) ADDITIONAL LIGHTS 0 ORDER IMMEDIATELY, LONG LEAD TIME '1) WELDING RODS 3) EXIT/EMER. LIGHTS 0 0 0 0 B. CARPET 4) LAMPS TENANT PROVIDE, G.C. INSTALL C. TRANSITION STRIPS 0 0 2. WALLS 0 0 A, WIRING & JACKS A. PAINT 0 0 O 1B. RUB RAIL 0 0 0 0 O j3. BASE 0 0 0 'A. VINYL O 0 4. CEILING DIVISION OF WORK DIVISION LLD GC SCOPE OF WORK TENANT GC SCOPE OF WORK EXISTING REMARKS LANDLORD TENANT CONTRACTOR LANDLORD TENANT CONTRACTOR A. ACOUSTIC TILE 0 B. PAINT ON GYP. BD 0 C. GRID 0 10 - SPECIALTIES 1. LAVATORY SPECIALTIES 0 0 GRAB BARS BY G.C. 2. STOREFRONT SIGN O 11 - SPECIALTIES O 1. FIRE EXTINGUISHERS 12 FURNISHINGS 1. CABINETRY 0 0 HOME DEPOT ITEMS BY G.C. INSTALLED BY FIXTURE CO. 2. FRAME DISPLAY FIXTURES 0 3. CASH REGISTERS O 4. FURNITURE 0 13. - MECHANICAL O NEW UNITS 1. HVAC A. DIFFUSERS 0 B. RETURNS 0 C. INT. DISTRIBUTION NETWORK 0 D. FINAL HVAC CHECK & BALANCE O E. INSPECT & SERVICE 0 2. TEMPERATURE CONTROL 0 3. EXHAUST FANS O 4. PLUMBING 0 A. TOILET ROOM 0 1)WASTE WATER & VENT O 0 INSTALL NEW 2) FIXTURES 5. WATER HEATER 0 6. SPRINKLER SYSTEM 0 0 RELOCATE HEADS AS REQUIRED 7. WATER COOLER 0 0 NEW NEW 8. MOP SINK 9. OTHER SINKS O NEW AS SPECIFIED EXAM ROOMS (2), BREAK AREA CONTACT LENS AREA 0 0 16 - ELECTRICAL 1. VOLTAGE AND PHASE O A. UPGRADE 0 2. SUB PANEL 0 A. SIGN J -BOX O B. SIGN TIMECLOCK 0 3. SMOKE EXHAUST SYSTEM O IF REQUIRED 4. SMOKE DETECTOR SYSTEM O IF REQUIRED 5. FIRE ALARM SYS. & DEVICES 0 IF REQUIRED 6. RECEPTACLES 0 7. LIGHT FIXTURES 0 A. LIGHTS 0 ORDER FROM CAPITOL LIGHT 1)2X4 & 2X2 FLUOR. O 2) ADDITIONAL LIGHTS 0 3) EXIT/EMER. LIGHTS 0 4) LAMPS 0 8. TELEPHONE 0 0 A, WIRING & JACKS 0 0 B. CONDUIT 9. DATA UNE CONDUIT 0 0 0 0 10. COMPUTER OUTLET CONDUIT 0 0 OWNER: on ac s LAWREN GROUP Austin Charlotte New York St. Louis 319 N. Fourth Street Suite 1000 St. Louis, MO 63102 p314-231-5700 f 314-231-0816 Project Address: Parkway Super Center 17334 Southcenter Parkway Tukwila, WA 98188 Gr ozie Ristera to Meir e Welrho Municipality: City of Tukwila Permit Center 6300 Southcenter Blvd., #100 Tukwila, WA 98188 P: 206.431.3670 Property Manager: Contact: Matt Barker Kimco P: 425-641-9717 mbarkerCa?kimcorealty.com I P.ihrle k'sPresS: The Old Speg'hetli Faetery. Kohl's Tuk'nifs -. Pr1co Animal Supplies 0 taordetromaurk.. Pro Golf 1110 South, Heti Robin Gourmet Burgers 17334 Southcenter Parkway:: 96-t Buy till Pier Imports' .. M eheels° Jo -Aho Fabrics ued Crafts Vicinity Map CONTACTS Owner's Rep: General Contractor: Project Manager: MEP Engineer: V America's Best Contacts & Eyeglasses Contact: Paul Myrick 470.448.2588 To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 LIST OF DRAWINGS Ordering Column Architectural 2 2 2 2 2 2 2 2 2 2 Mechanical 3 3 3 Sheet Name Cover Sheet Demolition Floor Plan Construction Plan Fixture/Equipment Plan Finish Plan Electrical Plan Reflected Ceiling Plan Elevations/Details Partition Types Accessibility/Life Safety Plan HVAC Plan HVAC Schedules & Details HVAC Specifications PROPOSED SPACE Ordering Column Electrical 4 4 4 4 4 4 4 Plumbing 5 5 5 5 5 Sheet Name Lighting Plan Power & Systems Plan Electrical Schedules & Details Electrical Schedules & Details Electrical Specifications Electrical Specifications Electrical Specifications Plumbing Plan - Waste and Vent Plumbing Plan - Water Plumbing Specifications and Risers Plumbing Details Fire Sprinkler Specifications Site Plan N FILE COPY Permit tAl - a ir Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date:. -25--17 City of Tukwila BUILDING DIVISION REVISIONS No changes shall hn made to the scope of work withoi.prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review tees. asses Professional Seal: i7 i1, i E EQUi ED 1:OR: t //Mechanical Eit Electrical lumbing Gas Piping City of Tukwila BUILDING DIVISION r. ,00 David W. Ohlemeyer: Architect The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. CODE SUMMARY Applicable Building Codes: WASHINGTON STATE BUILDING CODE 2015 INTERNATIONAL BUILDING CODE 2015 NATIONAL ELECTRIC CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 UNIFORM PLUMBING CODE WASHINGTON STATE ENERGY CODE SPRINKLER PLANS SHALL BE SUBMITTED AND APPROVED SEPARATELY BY THE CITY, PRIOR TO THEIR MODIFICATIONS. Construction Type: IIB, UNPROTECTED FULLY SPRINKLERED Occupancy: (M) MERCANTILE Project Area: SALES/PUBLIC: 2515 SF / 60 = 42 PERSONS BUSINESS: 890 SF / 100 = 9 PERSONS STORAGE: 305 SF / 300 = 2 PERSONS TOTAL OCCUPANT LOAD: 53 PERSONS TOTAL LEASE SQUARE FOOTAGE: 3986 This drawing and details on it are the sole property of the architect a project only. It shall not be loaned, copied or reproduced, in whole project without the written consent of the architect. No. Description REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 ld may be used for this specific grin rt, or for an ,Ei;fr purpos pity of Tu ' ►Dte BUILDING DIVISION e or RECEIVED CITY OF TUKWILA 1 4 2017 TER Project Number: 17903.029 Issue Date: 06/22/2017 n N eD a) c� 0 cris Project Name: America's Best Contacts & Eyeglasses a) E z a) 0) N O Cl) CD 0) Project Number: C:\Users\areinhardt94\Documents\pin_l7903_029 areinhardt94.rvt 1 101 DEMOLITION KEYED NOTES Key Value Keynote Text 101 EXISTING STOREFRONT GLAZING TO REMAIN. CLEAN TO LIKE -NEW CONDITION. 102 EXISTING DEMISING WALL TO REMAIN. CONFIRM EXISTING GYPSUM BOARD ON TENANT APMEWED SIDE EXTENDS TO DECK, IS INSULATED, AND IS CAULKED AND SEALED AT DECK AND ALL PENETRATIONS. IF EXISTING WALL DOES NOT MEET THESE REQUIREMENTS, EXTEND GYP. BOARD, INSULATE, AND CAULK TO PREVENT SOUND/SMELL 110 TRANSFERENCE FROM ADJACENT TENANT. USE UL#465 1 -HR DEMISING WALL FOR 111 STANDARDS COMPLIANCE. GC TO FIELD VERIFY LOCATION, MAINTAIN ALL REQUIRED 112 RATINGS. PATCH & REPAIR AS REQUIRED TO ACCEPT TENANT'S FINISHES. 103 REAR EXIT DOOR TO REMAIN & BE REUSED. EXISTING CONDITION EMPTIES INTO 113 BUILDING EXTERIOR. 104 GC SHALL FIELD VERIFY LOCATION OF EXISTING COLUMN WITHIN THE TENANT SPACE 114 ONCE DEMOLITION HAS BEEN COMPLETED. IN THE EVENT THERE IS A COLUMN BUD DING DIVISION DISCOVERED, CONTACT CUSHMAN & WAKEFIELD IMMEDIATELY. 105 REMOVE MILLWORK/FIXTURES FROM PREVIOUS AMERICA'S BEST LAYOUT. REMOVE ANY EXISTING CHAIR RAIL/WAINSCOTTING THROUGHOUT THE TENANT SPACE, RELAMINATE/SKIM COAT WALLS AS REQUIRED TO ACCEPT NEW TENANT FINISHES. 106 REMOVE EXISTING FLOORING (SHEET VINYL, CARPET), VINYL WALL BASE & FLOORING ADHESIVES/FINISHES THROUGHOUT TENANT SPACE, TYP. REMOVE ANY FLOOR MOUNTED POWER/LOW VOLTAGE & INFILL. PATCH, REPAIR, & LEVEL SLAB AS REQUIRED TO ACCEPT NEW FLOORING FINISHES. 107 EXISTING RESTROOM(S) TO REMAIN AND BE REUSED. RESTROOMS FIXTURES AND LAYOUT TO REMAIN UNALTERED. REMOVE EXISTING FINISHES FROM WALLS & FLOORS IN PREPARATION FOR NEW FINISHES PER PLANS. CLEAN FIXTURES TO LIKE -NEW CONDITION AND CONFIRM FIXTURES ARE IN GOOD WORKING ORDER. DEMOLITION KEYED NOTES Key Value Keynote Text 108 REMOVE EXISTING CEILING & CEILING ELEMENTS THROUGHOUT TENANT SPACE, TYP. UNLESS OTHERWISE NOTED. INCLUDING EXISTING LAY -IN CEILING, LAY -IN LIGHTING, GYPSUM BOARD CEILING/SOFFITS, SUSPENDED LIGHTING, CEILING FANS, DIFFUSERS, EXIT SIGNS, WALL PACKS, ETC. PATCH WALLS AS REQUIRED AT REMOVED WALL PACKS. PREPARE FOR INSTALLATION OF NEW CEILING & FIXTURES. 109 REMOVE EXISTING PARTITIONS, DOOR & FRAME ASSEMBLIES THROUGHOUT AREA OF APMEWED WORK AS SHOWN. ALL OTHER PARTITIONS TO REMAIN. PATCH & REPAIR ADJACENT SURFACES TO ACCEPT TENANT'S NEW FINISHES. 110 PREP ALL WALLS TO REMAIN THROUGHOUT TO ACCEPT NEW FINISHES PER PLANS. 111 DEMO PORTION OF EXISTING WALL IN PREPARATION FOR NEW DOOR. 112 REMOVE EXISTING STOREFRONT DOOR AND PREP OPENING FOR NEW STOREFRONT DOOR. 113 REMOVE EXISTING STOREFRONT DOOR AND PREP OPENING TO BE INFILLED WITH NEW STOREFRONT GLAZING TO MATCH BUILDING STANDARD. 114 REMOVE EXISTING PLUMBING FIXTURE AND CAP PLUMBING BELOW GRADE AS BUD DING DIVISION REQUIRED. PREP SURFACES TO ACCEPT NEW FINISHES. 115 ELECTRICAL TO REMAIN AND BE REUSED. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 112 113 109 109 102 109 105 106 108 110 TYP. 109 109 104 L_ 109 L_ r 109 I _J 109 109 _/ 109 tJ 102 LI 109 P 109 111 109 107 115 f1 Demolition Floor Plan A1.1 1/4" = 1'-0" 103 LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: To Be Selected Project Cushman & Wakefield Manager: Contact: Christine Campbell 314.392.2617 MEP Schnackel Engineers, Inc. Engineer: Contact: Mike Kilgore 402.391.7680 Professional Seal: Project Title: America's Best Contacts & Eyeglasses The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned co ied or re roduced, in whole or part, o writter or any efiI- 1 V Kw'- aat cons f i T' CODE COMPI IANCF the No. APMEWED Date JUL 2 6 2017 City of Tukwila BUD DING DIVISION RECEIVED CITY OF TUKWILA JUL 1 4_2017 PERMIT CENTER Sheet Title: Demolition Floor Plan Project Number: Sheet Number: C:\Users\areinhardt94\Documents\pin_17903 029 areinhardt94.rvt GRAPHIC LEGEND GENERAL NOTES PLUMBING NOTES Ox X NEW DOOR AND DOOR NO. SEE A6 FOR DOOR SCHEDULE EXISTING DOOR AND DOOR NO. SEE A6 FOR DOOR SCHEDULE PARTITION TYPE INDICATOR SEE SHEET A6.1 FOR DETAILS r\.7 ELECTRICAL EP PANEL X X ELEVATION X REFERENCE MARKER I I I////I EXISTING WALL NEW WALL NEW INSULATED WALL NEW TENANT SEPARATION WALL DETAIL REFERENCE MARKER SECTION REFERENCE MARKER 2A:10B:C FIRE EXTINGUISHER VERIFY FINAL LOCATION WITH FIRE MARSHAL IN FIELD GC TO PROVIDE AND INSTALL AS INDICATED, SEE FIRE EXTINGUISHER NOTES FOR MOUNTING INFORMATION 1. ALL NEW CONSTRUCTION AS INDICATED BY GRAPHIC LEGEND. 2. GENERAL CONTRACTOR IS COMPLETELY RESPONSIBLE FOR VERIFYING ALL AS -IS CONDITIONS AT PROJECT SITE. 3. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE CODE ACCEPTABLE PROJECT. HE MUST ALSO SATISFY ALL LANDLORD REQUIREMENTS AND TENANT'S FINAL PUNCH LIST NEEDS. 4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY FIRE RESISTIVE WOOD BLOCKING BACKERS FOR ATTACHMENT OF ANY WALL HUNG ACCESSORIES, CASEWORK, ETC. 5. CONTRACTOR TO PROVIDE STUD SUPPORT AT DOOR FRAMES, BACKERS, AND ANY NECESSARY SHORING OF WALLS. 6. ALL CUSTOM FIXTURES THRU-OUT TENANTS SALES AREA WILL BE SUPPLIED AND INSTALLED BY TENANT'S FIXTURE COMPANY IN COORDINATION WITH TENANT'S GENERAL CONTRACTOR. 7. NO CHANGE IN USE OR EGRESS. 8. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF LOCAL BUILDING CODES AND ALL OTHER APPLICABLE BUILDING CODES. 9. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS SHOWN ON THE PLAN AT THE JOB SITE PRIOR TO COMMENCING WORK. 10. CONSTRUCTION CANNOT BE ALLOWED TO BEGIN UNTIL A PERMIT HAS BEEN SECURED. GC RESPONSIBLE FOR PICKING UP PERMIT FOR TENANTS SCOPE OF WORK. 11. ALL FINISH WOOD SHALL BE KILN DRIED, W/ MILL QUALITY FINISH AND ALL WOOD SHALL RECEIVE A FIRE RETARDANT COATING OR TREATMENT. NO WOOD OR OTHER COMBUSTIBLE MATERIAL SHALL BE USED ABOVE ANY CEILING. 12. STRUCTURAL LUMBER TO BE DOUGLAS FIR #1 COMMON fs 1450 P.S.I. 13. ALL LUMBER TO BE GRADE MARKED PRIOR TO DELIVERY TO THE SITE. 14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL UTILITIES W/ CUSHMAN & WAKEFIELD PROJECT MANAGER. 15. THE CONTRACTOR IS RESPONSIBLE FOR SHORING AND BRACING ALL EXCAVATIONS IN ACCORDANCE W/ CITY, STATE AND OSHA REQUIREMENTS. 16. EXTERIOR SIGNAGE TO BE PROVIDED AND INSTALLED BY TENANT'S SIGN CONTRACTOR (UNDER A SEPARATE PERMIT). GC TO COORDINATE ELECTRICAL REQUIREMENTS W/ SIGN VENDOR. 17. ALL FIXTURES, FURNITURE AND CABINETRY TO BE INSTALLED BY TENANT'S VENDOR, U.N.O. GC TO INSTALL BLOCKING WHERE REQUIRED. 18. PHONE BOARD TO BE MOUNTED VERICALLY (4'X8') @ 2'-0" AFF. 19. PROVIDE 16 GAUGE METAL STUD FRAMING AT ALL DOOR OPENINGS TO PROVIDE ADDITIONAL BRACING. 1. FIXTURE CONTRACTOR SHALL PLACE SINKS AND FAUCETS IN COUNTERTOPS. CONTRACTOR SHALL PROVIDE PLUMBING ROUGH -IN AND FINAL PLUMBING CONNECTIONS. 2. PROVIDE SINKS WITH MINIMUM 1 1/2" WASTE LINES, 1/2" HOT AND COLD WATER LINES, UNLESS GOVERNING AUTHORITIES REQUIRE LARGER SIZES. 3. CONTRACTOR SHALL TRENCH EXISTING FLOOR SLABS AS NECESSARY, AND FILL LEVEL AND SMOOTH TO ADJACENT SLAB WITH CONCRETE OF STRENGTH EQUAL TO EXISTING SLAB. 4. PROVIDE CONCEALED SHUT OFF VALVES ON HOT AND COLD WATER LINES AT EACH SINK. 5. DRAIN, VENT AND WATER PIPING SHALL MEET THE REQUIREMENTS OF THE GOVERNING AUTHORITIES AND APPLICABLE CODES. PLUMBING SCHEDULE EX = EXISTING FIXTURE, REL = RELOCATED FIXTURE P-1 WATER CLOSET: SEE PLUMBING FOR SPECIFICATIONS. P-2 LAVATORY: SEE PLUMBING FOR SPECIFICATIONS.. P-3 WATER HEATER: SEE PLUMBING FOR SPECS. LOCATE IN PLENUM ABOVE CEILING. P-4 P-5 EXAM ROOM SINK: BAR SINK W/BAR FAUCET - TENANT GC PROVIDED - SEE PLUMBING FOR SPECIFICATIONS. BREAKROOM SINK: STANLESS STEEL SINK W/BAR FAUCET - TENANT GC PROVIDED - SEE PLUMBING FOR SPECIFICATIONS. P-6 ELECTRIC HI -LO WATER COOLERS: SEE PLUMBING FOR SPECIFICATIONS. P-7 SERVICE SINK: SINK WITH WALL MOUNTED FAUCET. SEE PLUMBING DRAWINGS FOR SPECS. NOTE TO CONTRACTOR FIRE EXTINGUISHER NOTES IT IS THE CONTRACTORS RESPONSIBILITY TO THOROUGHLY REVIEW THE OWNER'S DESIGN INTENT DRAWINGS & NOTIFY THE ARCHITECT IMMEDIATELY WITH ANY MAJOR DISCREPENCIES. THE ARCHITECT SHALL IN NO WAY BE HELD RESPONSIBLE FOR ANY DIFFERENCES BETWEEN THE DESIGN INTENT AND ARCHITECT PROVIDED DRAWINGS. 1) WALL MOUNTED FIRE EXTINGUISHER: (F.E.) LARSEN'S MFG. COMPANY #MP -5 (2A:10B:C), MP SERIES, DRY CHEMICAL, COLOR: RED OR APPROVED EQUAL THE HANDLE OF THE FIRE EXTINGUISHER IS TO BE MOUNTED NO HIGHER THAN 42" WITH THE LEADING BOTTOM EDGE MOUNTED 27" MAXIMUM FOR CANE DETECTION TO COMPLY WITH ANSI A117.1 SECTION 307.2 PROTRUSION LIMITS. NOTE: SEE PLUMBING SHEETS FOR ALL FLOOR DRAIN & CLEANOUT INFORMATION NOTE: GENERAL CONTRACTOR TO ORDER SINKS AND FAUCETS @ 102, 108, 111, 112 & 113. CONTRACTOR TO ORDER & PROVIDE ALL OTHER PLUMBING RELATED FIXTURES. (FIXTURE VENDOR TO SUPPLY UPPER & BASE CABINETS @ CONTACT LENS 102, FIXTURE VENDOR TO SUPPLY BASE CABINET & COUNTERTOP @ CONSULTATION 111 & 112) ADJACENT TENANT TBD 99' - 2" 1 CONSTRUCTION FLOOR PLAN A1.2 1/4" = 1'-0" ADJACENT TENANT TBD REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2011 City of Tukwila BUILOINO DIVISION LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: Professional Seal: Project Title: America's Best Contacts & Eyeglasses To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 ■'1 c� ■ 4E-10 0 a (/) co > co r a. co The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, In whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date RECEIVED CITY OF TUKWILA JUL .14 20» PERMIT CENTER Sheet Title: Construction Plan Project Number: Sheet Number: 1 4'-0" 2'-8" 23'-2" 2'-4" 5'-0" 18'-6" 12'-4" 6'-0" 7'-8" 9'-0" 5'-11" (HOLD) (HOLD) (HOLD) (HOLD) 1 1 �- �J r , -ate _ (__ . . r N O O L J ---=i�a c, , L supply I Supply 1O SIGN FASCIA CURTAIN ® 113 Manager's WALL ABOVE O4 O Office , , Office _. Mens Women's To ALIGN 110 114 Restoom Restroom r _PHONE <> T T Reception/Dispense BOARD 106 107 100 00 J O 0'�8' 7"y 8'- 6" 2' 5" J O I t_- I (HOLD) (HOLD) O. //C:14- \-) �110� C115) ( (� 1 C106) (- 11 , 07_ -1 -, ---- --__ '� O - Passage 6' 2" 2' 8" o �100D O Contact z 1-w 105 RI- (1 17) . . Lens n o - - z -� io r o 102 6 Q oo FE 1J N (118 I s, FE N OJ ¢ 0) r O P-3 ABOVE - WH r1 Supply _ _ ¢ Q - = Waiting MOP SINK Mop N 0 "' !--0 1 118 N z- C7 109 117 P-7 L STEEL TUBE & EXISTING COLUMN W/ C, [; PLATE LOCATION, P-4 io ! GYP. BOARD BOXING` �I TYP. -- ____.__._._...._-_-_._ _ ' 3 O Di 18' 7" 18' 4" 4' 0" \ y3s c I o T 9' 1" I „ 10" 8" 7" ^ .-......._ ,ti ALIGN = 'do Mechanical zt C° 116 3'- 10" 0 t I C 103 rr + 1 rN __. __._-.__.._......... J ... ... ...T..•....•......a L 108 T� - - _ VERIFY FINAL FIXTURE & METAL PIPING SYSTEM SPECIFICATIONS & O OU ;___1:-_-___ • • 2 O 0 N 1 iv LOCATIONS WITH NVI `-- Display P - 5' 0" 9'-6" 101 Pre -Consult ► Pre -Consult Consult • Consult Breakroom - r 103 ► 104 ► T 111 8' 9" 8'-9" 112 2' 108 - 7" 6'-0" 5'-10" Zo Eci o P-4 P-4 P-5 0-1 I ° O -1 ° O 0 1 000 35'-4" 11'-2" 11'-2" I 12'-5" 12'-5" 14'-5" ( 99' - 0" � � A 1 CONSTRUCTION FLOOR PLAN A1.2 1/4" = 1'-0" ADJACENT TENANT TBD REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2011 City of Tukwila BUILOINO DIVISION LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: Professional Seal: Project Title: America's Best Contacts & Eyeglasses To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 ■'1 c� ■ 4E-10 0 a (/) co > co r a. co The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, In whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date RECEIVED CITY OF TUKWILA JUL .14 20» PERMIT CENTER Sheet Title: Construction Plan Project Number: Sheet Number: 1 C:\Users\areinhardt94\Documents\pin_17903 029 areinhardt94.rvt N O) O efi O N M N 2 Irl 1 FIXTURE/EQUIPMENT KEYED NOTES FIXTURE GENERAL NOTES HOME DEPOT ITEMS (OR EQUAL)PROVIDED BY GC INSTALLED BY AMERICA'S BEST VENDOR FIXTURE SCHEDULE Key Value 1 Keynote Text 1. FIXTURE CONTRACTOR TO PROVIDE WIRE SKU# QTY. DESCRIPTION FIXTURE DESIGNATION DESCRIPTIONREMARKS FIXTURE DESIGNATION DESCRIPTION REMARKS MANAGEMENT FOR POWER AND DATA WITHIN 'DISPENSING COUNTER' AND 'RECEPTION COUNTER'. "4" WIDE PANEL 00 16 COMPUTER SHROUD O 201 MILLWORK SUPPLIED AND INSTALLED BY AMERICA'S BEST VENDOR. WIRE MANAGEMENT TO RUN ON EMPLOYEE SIDE OF 223-346 1 RIDGID WET DRY VACUUM WD1245 12 GAL. "2" WIDE PANEL N/A 17 BASE CABINET A411 GENERAL CONTRACTOR TO COORDINATE LOCATION WITH ELECTRICAL & PLUMBING ROUGH PRIVACY WALL BELOW COUNTERTOP. COORDINATE LOCATIONS AND LENGTH OF RUNS WITH 606991 1 24 IN. X 30 IN. HIGH BEVELED EDGE WALL MIRROR -INS. "3" WIDE PANEL 00 18 BASE CABINET B 0 202 SHELVING - ATLANTIC FIXTURE WILL BE SUPPLYING AND INSTALLING ELECTRICAL. 130-920 1 HUSKY 8' LADDER TYPE 1 250 # THE SHELVING IN THE SUPPLY AREAS. 2. GENERAL CONTRACTOR TO COORDINATE 30 YARD 696307 1 CHROME KWIK FIT KITCHEN SINK STRAINER O SUNGLASS DISPLAY 00 19 EXAM ROOM COUNTER OB 203 BOOKSHELVES AND COAT RACK SUPPLIED BY NVI. DUMPSTER ON SITE FOR FIXTURE INSTALLATION. EMPTY DUMPSTER AND RETURN TO JOB SITE FOR 353499 1 PLASTIC MIRROR MOUNTING CLIPS, SUPERSLIDEA (R) O OFFICE FURNITURE OB 20 POS CABINET O 204 GC TO SUPPLY AND INSTALL CHANGING TABLE KOALA KARE KB200-05 WHITE GRANITE. STORE MERCHANDISING. REMARKS O LOCKERS O 21 SALES COUNTER 'DOUBLE' OB 3. NOTE: THERE WILL BE NO X-RAY OR LASER FIXTURE CONTRACTOR TO VERIFY AND COORDINATE LAYOUT OF WALL CABINETS WITH AM. MACHINES ON-SITE A O BEST PRIOR TO INSTALLATION — OSALES — COUNTER SINGLE' N/A 22 TINT COUNTER N/A 0 PROVIDED AND INSTALLED BY AMERICA'S BEST VENDOR ODISPENSING UNIT N/A 23 DISPENSING COUNTER - LFT. HAND O NOT USED O CUSTOMER WRITE-UP O 24 RECEPTION COUNTER - LFT. HAND O ® SMALLER OPTION - 18" X 18" CABINET 10 WAITING AREA SEATING O 25 PRE -EXAM ROOM COUNTER O ID SMALLER OPTION - 18" X 18" CABINET 11 MANAGER'S SAFE O 26 MANAGER'S OFFICE FURNITURE O 12 CONTACT LENS BACK COUNTER O 27 BASE CABINET & COUNTERTOP O 13 CONTACT LENS WALL CABINET O 28 BREAK COUNTER O 14 WALL SIGNAGE PIPING O 29 MIRROR PANEL 00 EDCONTACT COUNTER LENS CUSTOMER O 30 FLAT SCREEN TELEVISION OB 31 NETWORK CABINET O r SLATWALL 4'-0" W x 4'-0" H L J ROLLING FILES SUPPLIED AND INSTALLED BY AMERICA'S BEST VENDOR Reception/Dispense 100 COPIER PROVIDED BY AMERICA'S BEST SHREDDER ON FLOOR PROVIDED BY AMERICA'S BEST VENDOR COUNTERTOP PRINTER Supply 113 202 COUNTERTOP Manager's PRINTER —1"-- Office =Office Men's Restoom 106 Women's Restroom 107 Supply 115 201 Contact Lens 15 ALL CHA RS AND SEATING SUPPLIED BY AMERICA'S BEST VENDOR THROUGHOUT, TYP. COUNTERTOP PRINTER COUNTERTOP PRINTER DESIGNER BRANDS FOR LESS FIXTURE FLOOR PLAN Il COUNTERTOP PRINTER Pre -Consult 103 u II 1 Pre -Consult 104 TYP. cp Waiting 109 INSTRUMENT SIDE - (PATIENT'S LEFT) Consult 111 -- 201 0 0 INSTRUMENT SIDE (PATIENT'S LEFT) EXAM DESK (PATIENT'S RIGHT) 4 4 44 • • A • • 4 4 Consult 112 201 0 0 Passage 105 GUEST CHAIR BY TENANT EXAM DESK (PATIENT'S RIGHT) REF Supply 118 202 Mechanical 116 Breakroom 108 FRIDGE BY AMERICA'S OBEST 28 201 GUEST CHAIR BY TENANT 0 0 • & A• • [203 A•••••••••A AAA A2 1/4" = LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: To Be Selected Project Cushman & Wakefield Manager: Contact: Christine Campbell 314.392.2617 MEP Schnackel Engineers, Inc. Engineer: Contact: Mike Kilgore 402.391.7680 Professional Seal: 0 tD 475 CU Project Title: America's Best Contacts & Eyeglasses a) a) a) 0 a) 0 (/)c0 > co coa. The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, In whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date HECEIVED CITY OF 1 I KWILA J11 -111F2017 PERMIT CENTER Sheet Title: Fixture/Equipment Plan Project Number: 03.0 Sheet Number: A2 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 City of Tukwila BUILDING DIVISION C:\Users\areinhardt94\Documents\pin_17903_029 areinhardt94.rvt GENERAL FINISH NOTES 1) NO SUBSTITUTIONS ON PAINT. PAINT SHOULD COMPLETELY COVER THE SURFACE WITH A SMOOTH, EVEN AND CONSISTENT FINISH. PAINT FINISH SHALL BE FREE OF CONTAMINATION FROM DUST, DEBRIS OR BRUSH AND ROLLER FIBERS. SAND BETWEEN COATS AS NECESSARY. CARE SHOULD BE TAKEN TO ENSURE PAINT IS NOT APPLIED TO ADJACENT HARDWARE OR WALL FINISHES. ANY PAINTING MISTAKES SHOULD BE COMPLETELY REMOVED IMMEDIATELY WITHOUT DAMAGE TO THE AFFECTED SURFACE. 2) PAINT ALL DOORS AND DOOR FRAMES PT -1; OIL BASED. 3) INTERIOR FINISHES (I.E. WALLS, CEILING TILES, ETC.) SHALL HAVE A FLAME SPREAD RATING OF 75 OR LESS WITH A MAX. SMOKE GENERATION FACTOR OF 450 IN CORRIDORS PER CODE. 4) G.C. TO PROVIDE ALL TOOLS, ACCESSORIES, ADHESIVES, ETC. AS NECESSARY TO INSTALL WALL AND FLOOR FINISHES, U.N.O. 5) G.C. TO PROVIDE & INSTALL INPRO CORNER GUARDS ON ALL EXTERIOR CORNERS IN PASSAGES, CORRIDORS, AISLES, HALLWAYS, WAITING ROOM AREAS, ENTRANCE TO CONTACT LENS ROOM, AND SALES AREA. 6) NVI TO PROVIDE ALL ACCESSORIES (I.E. TOILET AND HAND TOWEL DISPENSER) IN RESTROOMS, EXCEPT GRAB BARS & MIRROR WHICH SHALL BE PROVIDED BY THE GC. 7) NVI TO ORDER & PROVIDE NUSPRAYLOCK PLATINUM FLOORING ADHESIVE FOR ALL CARPET INSTALLATION. 8) CARPET WILL BE DELIVERED TO SPECIFIED LOCATION BY NVI. GC WILL BE RESPONSIBLE FOR UNLOADING AND BRINGING MATERIAL INTO THE BUILDING. 9) CARPET TILE TO BE INSTALLED IN MONOLITHIC DIRECTION. 10) NOTE: G.C. TO INSTALL ALL CARPETING PER MANUFACTURER'S SPECIFICATIONS. G.C. MUST PROVIDE DOCUMENTATION OF MOISTURE TESTING FOR BOTH EXISTING AND GREEN CONCRETE TO BE APPROVED BY CUSHMAN & WAKEFIELD BEFORE CARPET INSTALLATION. THE MAXIMUM AMOUNT OF MOISTURE EMISSION FROM THE FLOOR IS 3.0 POUNDS PER 1,000 SQUARE FEET IN A 24 HOUR PERIOD. THE ACCEPTABLE PH RANGE IS 7.0 TO 9.0. THIS SPECIFICATION MUST BE MET IN ORDER TO KEEP ALL PRODUCT WARRANTIES IN PLACE AND PREVENT FLOORING FAILURE. GC MUST SEAL ALL GREEN CONCRETE. ONCE TEST IS REVIEWED, CUSHMAN & WAKEFIELD WILL NOTIFY THE G.C. HOW TO PROCEED. 11) INTERIOR FINISH NOTE: FINISHES THROUGHOUT AREA OF WORK MUST COMPLY WITH THE MINIMUM REQUIRED FLAME SPREAD CLASSIFICATIONS FOR INTERIOR FINISHES PER TABLE A 10.2.2. OF THE CURRENT LIFE SAFETY CODE. 12) LIFE SAFETY NOTE: GC SHALL ENSURE FLOOR SURFACES ON BOTH SIDES OF DOOR OPENING DO NOT VARY MORE THAN 1/2" AS REQUIRED BY SECTION 7.2.1.3.1 OF THE CURRENT LIFE SAFETY CODE. PER SECTION 7.2.1.3.2 THE ELEVATION OF THE FLOOR SURFACES REQUIRED BY 7.2.1.3.1 SHALL BE MAINTAINED ON BOTH SIDES OF THE DOOR FOR OPENINGS FOR A DISTANCE OF NOT LESS THAN THE WIDTH OF THE WIDEST LEAF. PER SECTION 7.2.1.3.3 THRESHOLDS AT DOOR OPENINGS SHALL NOT EXCEED 1/2" IN HEIGHT. GC SHALL FLOAT / REPAIR EXISTING FLOORING SURFACES TO MEET ALL OF THE REQUIREMENTS LISTED ABOVE AND OF SECTION 7.2.1.3 FLOOR LEVEL. FINISH LEGEND FLOORING CPT1 CPT2 MILLIKEN - S4S004-00S70 SIZE 20"X20", NAME: DELINATE. SUPPLIED BY AMERICA'S BEST CONTACTS AND EYEGLASSES, INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR TO MEASURE AND REQUEST CARPET FROM NATIONAL VISION, INC./ CUSHMAN & WAKEFIELD AS SOON AS CONTRACT IS AWARDED TO ENSURE TIMELY DELIVERY TO JOBSITE. MILLIKEN - WALK OFF CARPET -4043-20S SIZE 20"X20", NAME: CLEEN SWEEP. SUPPLIED BY AMERICA'S BEST CONTACTS AND EYEGLASSES, INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR TO MEASURE AND REQUEST CARPET FROM NATIONAL VISION, INC./ CUSHMAN & WAKEFIELD AS SOON AS CONTRACT IS AWARDED TO ENSURE TIMELY DELIVERY TO JOBSITE. VCT MANNINGTON SAFE WALK 12X12 TILES, COLOR 800 NAVY, TYPE 4 GC TO PROVIDE QUOTE FOR INSTALLATION & MATERIAL; GC TO PROVIDE GLUE / ADHESIVE FOR VCT. GC TO STRIP AND WAX THE VCT FLOORS; THEN USE THE ZEP ZEP HIGH TRAFFIC FLOOR FINISH (CAN BE PURCHASED AT HOME DEPOT, ETC.) FLOORING ADHESIVE GLUE STANDARD PRESSURE SENSITIVE GLUE - TO BE SENT WITH CARPET AND ORDERED BY NVI. VINYL BASE VB1 MANNINGTON: EDGE TP, 904 BARK. GC TO PROVIDE QUOTE FOR INSTALLATION & MATERIAL; 4" COVE VINYL WALL BASE (6" COVE IN RESTROOMS). GC TO PROVIDE GLUE / ADHESIVE FOR VINYL BASE. WINDOW FILM WF LUMARR: LUMARR ILLUSIONS, FROST SERIES - FROST (NRM PS2), POLYESTER, PRESSURE -SENSITIVE ADHESIVE. RUBRAIL RR SPEC INPRO RIGID VINYL RUBRAIL. 1.800.222.5556, WWW.INPROCORP.COM, 6" (153 MM) HEIGHT, .060" (1.5 MM) THICK, COLOR: TAUPE 0133 - CONTACT INPRO REP FOR ORDERING: DAVID MIKULICE - 800.214.7749 x 5034 / DMIKULICE@INPROCORP.COM CORNER GUARDS CG1 SPEC INPRO CORNER GUARD, IPC -SMOOTH, FLEXIBLE CORNER GUARD. 1.800.222.5556, WWW.INPROCORP.COM 1-1/2: (38 MM) WING, .110" (2.8MM) THICK FLEXIBLE VINYL. 4' (1.22M), COLOR: SILVER 0105 PAINT PT1 PT2 PT3 PT4 PROVIDED AND INSTALLED BY G.C. SHERWIN WILLIAMS, COLOR -HERON PLUME #6070, SEMI -GLOSS FINISH PROVIDED AND INSTALLED BY G.C. SHERWIN WILLIAMS, COLOR -AGREEABLE GRAY #7029, SEMI -GLOSS FINISH PROVIDED AND INSTALLED BY G.C. SHERWIN WILLIAMS, COLOR -PURE WHITE #7005, SEMI -GLOSS FINISH PROVIDED AND INSTALLED BY G.C. SHERWIN WILLIAMS, COLOR -AGREEABLE GRAY #7029, FLAT FINISH ACOUSTIC CEILING - SEE REFLECTED CEILING PLAN FOR NEW CEILING LOCATIONS ACT1 PROVIDED AND INSTALLED BY G.C. ARMSTRONG FISSURED SQUARE #755, WHITE, 24"X48"X3/4" INVERTED 'T' 15/16" WHITE GRID SUPPORTED WITH #10 TIE WIRE. OR APPROVED EQUAL. FLOORING TRANSITIONS TR1 TRANSITION STRIP: JOHNSONITE: STYLE: CTA -21-H. FROM 0.27" CARPET TO 0.125" VCT. 1 L J Supply 113 FINISH SCHEDULE Room Number Name Floor Finish Base Wall Finish Ceiling Finish Remarks 100 Reception/Dispense CPT1/CPT2 VB1 PT4 ACT1 A, B 101 Display CPT1 VB1 PT4 ACT1 A 102 Contact Lens CPT1 VB1 PT4 ACT1 A, B, F 103 Pre -Consult CPT1 VB1 PT4 ACT1 A, F 104 Pre -Consult CPT1 VB1 PT4 ACT1 A, F 105 Passage VCT VB1 PT4 ACT1 106 Men's Restoom VCT VB1 PT2 ACT1 D 107 Women's Restroom VCT VB1 PT2 ACT1 D 108 Breakroom VCT VB1 PT2 ACT1 A, F 109 Waiting CPT1 VB1 PT4 ACT1 110 Manager's Office CPT1 VB1 PT4 ACT1 F 111 Consult CPT1 VB1 VB1 PT4 PT4 ACT1 ACT1 A, F A, F 112 Consult CPT1 113 Supply VCT VB1 PT4 ACT1 114 Office CPT1 VB1 PT4 ACT1 F 115 Supply VCT VB1 PT4 ACT1 116 Mechanical VCT VB1 PT4 ACT1 117 Mop VCT VB1 VB1 PT2 PT4 ACT1 ACT1 C 118 Supply VCT FINISH KEYED NOTES Key Value Keynote Text 301 INSTALL INPRO RUBRAIL ALONG WALL AT 34" O.C. AFF. SEE FINISH LEGEND FOR SPECIFICATION (RR). REMARKS O O VINYL BASE TO BE INSTALLED AFTER FIXTURE CONTRACTOR INSTALLATION OF MILLWORK BASE CABINET GC TO PAINT ALL THE WAY UP SOFFIT TO CEILING; SEE SOFFIT DETAIL. GC TO SUPPLY FRP TO BE INSTALLED AS BACK SPLASH FOR THE WALLS TO THE LEFT, RIGHT AND BEHIND THE MOP SINK. FRP TO BE INSTALLED DURING FIXTURE INSTALL & COORDINATED W/FIXTURE INSTALLERS. INSTALL FRP TO 4'-0" A.F.F. IN RESTROOMS ON THREE WALLS - THE WALL BEHIND THE LAVATORY AND TOILET, THE WALL NEXT TO THE TOILET AND ON THE WALL NEXT TO THE LAVATORY. PAINT BULKHEAD AT STOREFRONT WHITE, PT -3. OINSTALL RUBRAIL ALONG WALLS AS INDICATED ON PLAN. -J Reception/Dispense 100 <°T> Sim 3011 Manager's Office CCPT1) 110 Supply 115 301 Men's Restoom 106 Women's Restroom 107 X <CPT> 6'-8" X 5'-0" WALK -OFF MATT (20"X20" CARPET TILES) X O Sim PT2) X <CPT> <CPT> <CPT1) L FINISH FLOOR PLAN LI I_ MOM 11 1 L_ — Contact Lens 102 301 <CPT> (CPT- Pre -Consult 103 301 (CPT ) 301 I 301 \f -T Sim Sim <OPT> 1 Passage 105 Sim Waiting 109 Sim X Mechanical 116 —�a 301 Pre -Consult 104 Consult 111 Consult 112 301 301 301 Breakroom 108 'XXYYYYYYYY YYyyYYyYYYYY) A3 1/4" = 1'-0" Supply 118 LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Professional Seal: Project Title: N U) crs a) o U U N m cts U E Ist H cri F - The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, Instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date RECEIVE CITY OF TUKWILA U PERMIT CENTER Sheet Title: Finish Plan Project Number: Sheet Number: C:\Users\areinhardt94\Documents\pin_17903_029 areinhardt94.nit ELECTRICAL LEGEND db V P V F V DUPLEX OUTLET * OUTLETS INSTALLED @ 18" AFF, UNO* QUADRAPLEX OUTLET SURFACE MOUNTED QUADRAPLEX OUTLET PHONE LINE PHONE LINE (PITNEY BOWES) PHONE LINE (FAX) DATA PORT 'EX' = DENOTES EXISTING ✓ POWER/DATA LINE D DEDICATED LINE (MODEM) H . DEDICATED LINE (HYPERCOM) O CEILING DUPLEX OUTLET JUNCTION BOX J ELECTRICAL PANEL l EP ELECTRICAL NOTES -PROVIDE (1) THREE -GANG RECESSED FOR POWER AND DATA, TO RECEIVE (1) QUAD RECEPTACLE AND (1) DUPLEX DATA/TELE PORT, INDICATED AS 'FB' OR 'WB' ON PLAN. -8800S2 -CAST IRON, EQUAL PLASTIC FLOOR BOX, THREE -GANG, FULLY ADJUSTABLE -827-PC-BLK THREE -GANG, POLYCARBONATE CARPET FLANGE -PROVIDE THREE -GANG POLYCARBONATE COVER PLATE TO ACCOMMODATE POWER AND DATA. -PROVIDE ONE 20 AMP CIRCUIT FOR NO MORE THAN (2) FLOOR BOXES. -G.C. TO INSTALL (3) 1-1/2" DIAMETER CONDUITS WITHIN FLOOR TO FLOOR BOX, (1) FOR POWER, (1) FOR DATA. RUN DATA CONDUIT UP NEAREST WALL AND EXTEND 6" ABOVE CEILING. PROVIDE FISH LINE WITHIN CONDUIT -PRINTERS REQUIRE TEL/DATA LINE SEPARATE FROM POS LINE BUT IN SAME FLOOR BOX. -ALL ELECTRICAL OUTLETS AND EXIT SIGNS PER TENANT'S PLANS -ALL UTILITIES TO BE SEPARATELY METERED BY LANDLORD -MOUNTING HEIGHTS SHALL BE TO CENTERLINE OF INDICATED DEVICE. -GC SHALL ENSURE THAT THE WIRES IN THE RTU DISCONNECT ARE COLOR CODED CORRECTLY, PER THE SITE SURVEY AND THE ELECTRICAL DRAWINGS. -GC TO INSTALL PHONE BOARD INCLUDING OUTLET AND CONDUIT WITHIN FIVE (5) DAYS OF CONSTRUCTION COMMENCEMENT. GC SHALL SEND A COMPLETION PHOTO TO CUSHMAN & WAKEFIELD PROJECT MANAGER AS SOON AS INSTALLED. PHONE BOARD NOTE GC TO INSTALL PHONE BOARD INCLUDING OUTLET AND CONDUIT WITHIN FIVE (5) DAYS OF CONSTRUCTION COMMENCEMENT. GC SHALL SEND A COMPLETION PHOTO TO CUSHMAN & WAKEFIELD PROJECT MANAGER AS SOON AS INSTALLED. #0000 INSTALL DATA JACK 45" O.C. ABOVE FINISHED FLOOR TO PROVIDE SUFFICIENT SPACE FOR WALL MOUNTED PHONE. 402 INSTALL DATA JACK AND OUTLET HORIZONTALLY AT 96" O.C. ABOVE FINISHED FLOOR TO PROVIDE SUFFICIENT SPACE a a at a -� RECEPTACLE a _- a a• _ a a _ a a a a _ a a _ a 6'-0" 5' - 0" GFCI RECEPTACLES DATA JACKS a _ a a _ a a a a _ a a a FIN. REMOVABLE PANEL & ENDS 2 CONTACT LENS ELEVATION A4 3/8" = 24" FRONT VIEW 3 A4 a Ln 22" 9" SIDE VIEW 0 LO ELECTRICAL KEYED NOTES Key Value Keynote Text 401 INSTALL DATA JACK 45" O.C. ABOVE FINISHED FLOOR TO PROVIDE SUFFICIENT SPACE FOR WALL MOUNTED PHONE. 402 INSTALL DATA JACK AND OUTLET HORIZONTALLY AT 96" O.C. ABOVE FINISHED FLOOR TO PROVIDE SUFFICIENT SPACE FOR TV MOUNTING DEVICE. PHONE BOARD CABINET ELEVATION 3/4" = 11-0" LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Project Title: SECURITY KEYPAD @ 48" 61" OUTLET TO BE ON 46" SWITCH FOR CAN LIGHTS & SURFACE MOUNTED FLUORESCENT ([2] FIXTURE TYPE 'D1', [3] FIXTURE TYPE 'E') IN THIS AREA 8'-0" (HOLD) 2, _ 9„ r 42" L• _L• 61" 46" L J 42" GFCI :::=J42" ()I GFCI J CONTRACTOR TO INSTALL J -BOXES ABOVE CEILING. PULL ELECTRICAL THROUGH WALL AND INSTALL ELECTRICAL & LV WHIP AT 2" A.F.F. COORDINATE FINAL TERMINATION POINT WITH FIXTURE VENDOR. Reception/Dispense 100 0 1- ..LiJ Supply 113 Supply 115 18" 0 PRINTER Manager's LOCATION Office 110 l EXISTING PHONE BOARD/ — EQUIP. 84" Men's Restoom 106 Women's Restroom 107 L _J 5' - 6" 5'-2" 12'-1" IL 5' - �II —J_1 2'- 4" 1'- 6" i a '4) 10'-11" 96" TV 96" 32'-1" Passage PR NTER LOCATION 105 [402 PROVIDE 30A DEDICATED CIRCUIT LOCATED ABOVE CEILING FOR SIGN. COORDINATE WITH SIGN VENDOR. Mo 117 0 Contact Lens 102 Waiting 109 :-a Display 101 Mechanical 116 0 I— EP w EXIST DUPLEX RECEPTICAL IN CEILING, TYP. erk 1§1 H W C) >.'— Lal CD 2 237: Late 2 •2 O s 15 Q W O • col The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. 4' - 0" n 4'-0" No. Description Date 8" Pre -Consult 103 44 18 18" Pre -Consult 104 Consult 111 Consult 112 Breakroom 108 14'-0" 11'-0" 10'-5" 62" 62" C 80" 80" 1'-6" 3'-0" 3'-0" n8" co 44" b 44" jy-4" 62" 44" 44" CO 1'- 4" 4 II 62" 44" V C 0 0 44" 44" t FRIDGE BY AMERICA'S BEST RECEIVED CITY OF TUKWILA I-46"— 46" — IGFCI GFCI 14 In 0 JUL 142017 0 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 PERMIT CENTER Sheet Title: City of Tukwila BUILDINGIVISION Electrical Plan Lf) 1 A4 ELECTRICAL PLAN 1/4" = 1'-0" Sheet Number: A4 C:\Users\areinhardt94\Documents\pin_17903_029 areinhardt94.rvt 1 CEILING PLAN LEGEND SYMBOL EX = DENOTES EXISTING FIXTURE DESCRIPTION REMARKS SYMBOL DESCRIPTION REMARKS SYMBOL DESCRIPTION REMARKS 2'x4' LED FIXTURE, PARABOLIC LENSE W/ BRUSHED METAL FINISH SEE ELECTRICAL SHEETS FOR SPECIFICATIONS. 2' X 2' SUPPLY DIFFUSER GENERAL CONTRACTOR TO INSTALL NEW. 2'x2' LED FIXTURE, PARABOLIC LENSE W/ BRUSHED METAL FINISH SEE ELECTRICAL SHEETS FOR SPECIFICATIONS. 2' X 2' RETURN DIFFUSER GENERAL CONTRACTOR TO INSTALL NEW. 3 STANDARD LIGHT SWITCH 3 -WAY LIGHT SWITCH, TO CONTROL FLUORESCENT LIGHT FIXTURES @ CONSULTATION ROOMS TRACK FIXTURES NOTE: DUE TO WEIGHT AND SPACE OF SPECIFIED LIGHTING, TRACK MUST BE MECHANICALLY FASTENED TO THE CEILING GRID. LENGTH OF TRACK AND NUMBER OF HEADS AS SHOWN ON PLAN. COORDINATE EXACT LOCATIONS, SPECIFICATIONS AND ACCESSORIES WITH TENANT. 1' X 2' RETURN AIR DIFFUSER GENERAL CONTRACTOR TO INSTALL NEW. LVD LVD LIGHT SWITCH, TO CONTROL GENERAL LIGHTING THROUGHOUT RECESSED INCANDESCENT FIXTURE 0D SEE ELECTRICAL SHEETS FOR SPECIFICATIONS. 2' X 4' RETURN DIFFUSER GENERAL CONTRACTOR TO INSTALL NEW. (DIM) DIMMER SWITCH, TO CONTROL CAN LIGHT FIXTURES @ CONSULTATION ROOMS 0D1 COMPACT FLUORESCENT OPEN DOWNLIGHTING OR APPROVED EQUAL C EXHAUST FAN SEE ELECTRICAL SHEETS FOR SPECIFICATIONS. (FAN) SWITCH, TO CONTROL EXHAUST FAN (FAN/LT) SWITCH, TO CONTROL EXHAUST FANS AND LIGHTS @ TOILET ROOMS WALL SWITCHES SHALL BE HEAVY DUTY, TOGGLE, QUIET TYPE, FULLY ENCLOSED IN COMPOSITE CASES, AND RATED 20 AMP AT 277 VOLT AC. USE SINGLE POLE, OR DIMMER AS SHOWN ON DRAWINGS. SIMILAR TO LEVITON DECORA SERIES (COLOR WHITE WITH WHITE COVERPLATE, TYPICAL THROUGHOUT AREA OF WORK) 4 -WAY SWITCH TO TO BE ON SAME CIRCUIT AS 3 -WAY SWITCHES AT ENTRANCE AND REAR EXIT 1'x4' (2) TUBE FLUORESCENT FIXTURE, SW STRIP - STANDARD TRIP WIDE OR EQUAL, SUBMIT SUBSTITUTIONS TO NVI FOR APPROVAL. MOUNT @ INSIDE OF SOFFIT, SEE SOFF ,,Am ' IL. EMERGENCY ILLUMINATION FOR BUILDINGS AND DURATION OF ILLUMINATION (1008.3.2--1008.3.5) In the event of power supply failure in Rooms and spaces, an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms, 2. Fire command centers, 3. Fire pump rooms, 4. Generator rooms, 5. Public restrooms with an area greater than 300 square feet. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. Illumination level under emergency power, the lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 footcandle and a minimum at any point of 0.1 footcandle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle average and a minimum at any point of 0.06 footcandle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. SWITCH FOR 61" OUTLET, CAN LIGHTS & SURFACE MOUNTED FLUORESCENT ([2] FIXTURE TYPE 'D1', [3] FIXTURE TYPE 'E') IN THIS AREA. SPRINKLER HEAD SUGGESTED HEAD LOCATION ONLY. SHOP DRAWINGS SHALL BE PER FIRE SPRINKLER TRACTOR / ENGINEER. 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied; illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. Vestibules at level of discharge, 5. Exterior landings and areas used for exit discharge. PROVIDE SINGLE POLE SWITCH FOR DISPLAY ROOM TRACK LIGHTING FIXTURES. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. COORDINATE SWITCHING WITH AMERICA'S BEST CONSTRUCTION MANAGER. — LIGHT SWITCH FOR SURFACE MOUNTED FLOURESCENT ([2] FIXTURE TYPE 'E') IN THIS AREA.— EXIT SIGN NEW LAY -IN CEILING TO BE INSTALLED AT 10'-0" A.F.F. THROUGHOUT, WITH EXCEPTION OF RESTROOM CEILINGS TO BE INSTALLED AT 8'-0" TYP. SEE MECHANICAL DRAWINGS FOR DIFFUSER LOCATIONS. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHT CIRCUITING INFORMATION. NOTE: LIGHT FIXTURES TO BE PURCHASED THROUGH NVI APPROVED VENDOR: CAPITOL LIGHT GC TO CONTACT MARIANNE K. ENES AT 860-520-2337 MARIANNE.ENES@CAPITOLLIGHT.COM C CONTRACTOR TO INSTALL J -BOXES ABOVE CEILING. PULL ELECTRICAL THROUGH WALL AND INSTALL ELECTRICAL & LV WHIP AT 2" A.F.F. COORDINATE FINAL TERMINATION POINT WITH FIXTURE VENDOR. • c N 0 0 KIDT4X C C U- LL. 0 co 2 A5 EXTEND STUDS TO STRUCT. ABV. SECURE FRAMING TO TOP CHORD OF JOIST ONLY AS REQ'D. VERIFY EXIST'G CONDITION 2-1/2"x20ga MET. STUD BRACING AT 4'-0" o.c. (ALTERNATE DIRECTIONS) SECURE TO TOP CHORD OF JOIST ONLY ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE REFLECTED CEILING PLAN FOR LAYOUT. TEARAWAY L -BEAD AS MANUFACTURED BY TRIM-TEX, LINCOLNWOOD, IL 800-874-2333 (1) LAYER 1/2" TYPE -X GYP. BD. EACH SIDE, AND UNDERSIDE, OF 3-5/8" 25 GA. MTL. STUDS AT 16" O.C.-PROVIDE CORNER BEAD, TAPE, SPACKLE, AND SAND READY FOR FINISHES SURFACE MOUNTED FLUORESCENT (PT4)PAINTON BOTH SIDES OF SOFFIT TO UNDERSIDE OF CEILING, TYP. (Pi -4) CURTAIN WALL FASCIA SECTION 1 1/2" = 1'-0" 3- r'= 40" 3 / (DIM 40" n„7- (DIM DIMMER SWITCH FOR CAN LIGHTS (FIXTURE TYPE 'D'), TYP. D MMER SWITCH FOR CAN LIGHTS (FIXTURE TYPE 'D'), TYP. DIMMER SWITCH FOR (DIM) CAN LIGHTS (FIXTURE 40" TYPE 'D'), TYP. DIMMER SWITCH FOR (DIM) CAN LIGHTS (FIXTURE 40" TYPE 'D'), TYP. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 City of Tukwila BUILDING DIVISION LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Professional Seal: 0 ID Project Title: U) U) U) LIJ 06 U) U co Oca ===, U . 4-, U) co . � E ctl F - The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date CITY OCEIVED F TUKWILA JUL 14 2011 PERMIT CENTER Sheet Title: Reflected Ceiling Plan REFLECTED CEILING PLAN A5 1/4" = 1'-0" te: 2017 Sheet Number: A5 © • ;FAN/LT) —1 3- r'= 40" 3 / (DIM 40" n„7- (DIM DIMMER SWITCH FOR CAN LIGHTS (FIXTURE TYPE 'D'), TYP. D MMER SWITCH FOR CAN LIGHTS (FIXTURE TYPE 'D'), TYP. DIMMER SWITCH FOR (DIM) CAN LIGHTS (FIXTURE 40" TYPE 'D'), TYP. DIMMER SWITCH FOR (DIM) CAN LIGHTS (FIXTURE 40" TYPE 'D'), TYP. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 City of Tukwila BUILDING DIVISION LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Professional Seal: 0 ID Project Title: U) U) U) LIJ 06 U) U co Oca ===, U . 4-, U) co . � E ctl F - The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date CITY OCEIVED F TUKWILA JUL 14 2011 PERMIT CENTER Sheet Title: Reflected Ceiling Plan REFLECTED CEILING PLAN A5 1/4" = 1'-0" te: 2017 Sheet Number: A5 C:\Users\areinhardt94\Documents\pin_17903_029 areinhardt94. nrt 0 0 (.1 co 2 N co a. DOOR SCHEDULE DOOR NUMBER I WIDTH I HEIGHT TYPE DOOR MAT'L FRAME MAT'L HARDWARE GROUP COMMENTS 100 3' - 6" 7' - 0" B MTL/GLASS METAL HD -H l / / 103 3' - 0" 7' - 0" A WOOD METAL HD -G EXISTING; UPGRADE HARDWARE AS REQUIRED 104 3'-0" 7'-0" A WOOD METAL HD -G MFG: CORBIN RUSSWIN 105 4' - 0" 7' - 0' C METAL METAL HD -E EXISTING; UPGRADE HARDWARE AS REQUIRED 106 3' - 0" 7' - 0" A WOOD METAL HD -D EXISTING; UPGRADE HARDWARE AS REQUIRED 107 3' - 0" 7' - 0" A WOOD METAL HD -D EXISTING; UPGRADE HARDWARE AS REQUIRED 108 3' - 0" 7' - 0" A A A WOOD METAL HD -C EXISTING; UPGRADE HARDWARE AS REQUIRED 110 3' - 0" 7' - 0" WOOD WOOD METAL HD -B EXISTING; UPGRADE HARDWARE AS REQUIRED EXISTING; UPGRADE HARDWARE AS REQUIRED 111 3' - 0" 7' - 0" METAL HD -A 112 3'-0" 7'-0" A WOOD METAL HD -A CYLINDRICAL (1) CL3510 NZD, 626, RU LOCK: MFG: CORBIN RUSSWIN 113 3'-0" 7'-0" A WOOD METAL HD -F HD D: BATHROOM PRIVACY SET 114 3' - 0" 7' - 0" A WOOD METAL HD -B EXISTING; UPGRADE HARDWARE AS REQUIRED 115 3' - 0" 7' - 0" A WOOD METAL HD -F EXISTING; UPGRADE HARDWARE AS REQUIRED 116 3' - 0" 7' - 0" 7' - 0" A D WOOD WOOD METAL HD -F EXISTING; UPGRADE HARDWARE AS REQUIRED PAIR; 2'-8" x 7'-0" EA. 117 5' - 4" METAL HD -J 118 2' - 0" 7' - 0" MFG: ROCKWOOD SILENCER: (3) 608, RO EXISTING; UPGRADE HARDWARE AS REQUIRED DOOR TYPES HD -A: PASSAGE SET 1 HD -E: ALARMED EXIT SET / / / HINGE: (3) TA714 4-1/2" X 4-1/2", US26D, MK / / CONTINUOUS (1) MCK-12HD, CL, MK l / / HINGE: MFG: MCKINNEY / A \ EXIT DEVICE: (1) V40xEB DEADLATCH: (1) 4900, 628, AD / // MFG: DETEX // / WALL STOP: (1) 409, US32D, RO / / / MFG: ROCKWOOD CYLINDER: 1080-118-A02-, 626, RU / / \ \ MFG: CORBIN RUSSWIN OPERATOR: MFG: ADAMS RITE \ \ z 0 CYLINDER: 1080-118-A03-, 626, RU \ \ CLOSER: MFG: NORTON MFG: CORBIN RUSSWIN \ \ \ \ \ / / PUSH/PULL (1) BF15747 MTG-TYPE 1, MFG: MCKINNEY MFG: PEMKO BAR: US32D-316, RO CYLINDRICAL CL3551 NZD ACP, 626, RU GASKETING: (1) 2891AS TKSP8, PE MFG: ROCKWOOD LOCK: MFG: CORBIN RUSSWIN MFG: PEMKO DOOR (1) UN17500, 689, NO MFG: NORTON WALL STOP: (1) 409, US32D, RO RAIN GUARD: (1) 346C TKSP8, PE A AW1 PC -5 GRADE WOOD DOOR B C D ALUM. METAL EXIT AW1 PC -5 GRADE STOREFRONT DOOR WITH WOOD DOOR, DOUBLE DOOR PANIC BI -FOLD W/ TEMPERED HARDWARE GLASS GENERAL DOOR NOTES 1) PAINT ALL DOORS AND DOOR FRAMES PT -1; OIL BASED; REFER TO SHEET A3. 2) USE KNOCKDOWN METAL DOOR FRAMES. 3) UNDERCUT 'SUPPLY' DOOR BOTTOM FOR MAKE-UP AIR TO EXHAUST FAN. 4) ALL NEW DOORS TO RECEIVE HINGES AS SPECIFIED. 5) ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. 6) DOOR HARDWARE: CALL LOCAL DISTRIBUTOR FOR HARDWARE ORDERS 7) PAINT EXTERIOR SIDE OF REAR DOOR TO MATCH BUILDING STANDARD. 8) ALL DOOR CLOSERS TO BE INSTALLED ON INTERIOR SIDE OF ROOM/SPACE, TYP. KEYING NOTES 1. MANAGER'S OFFICE - PROVIDE MASTER KEY FOR ALL LOCKS THROUGHOUT. ***VERIFY ALL KEYING WITH NATIONAL VISION, INC. CONSTRUCTION MANAGER PRIOR TO INSTALLATION. HARDWARE SCHEDULE ALL HARDWARE TO BE SUPPLIED AS SPECIFIED; APPROVED EQUALS BY OWNER HD -A: PASSAGE SET 1 HD -E: ALARMED EXIT SET HD -H: STOREFRONT ENTRY HINGE: (3) TA714 4-1/2" X 4-1/2", US26D, MK CONTINUOUS (1) MCK-25HD 83", CL, MK CONTINUOUS (1) MCK-12HD, CL, MK MFG: MCKINNEY HINGE: MFG: MCKINNEY HINGE: MFG: MCKINNEY CYLINDRICAL (1) CL3510 NZD, 626, RU EXIT DEVICE: (1) V40xEB DEADLATCH: (1) 4900, 628, AD LOCK: MFG: CORBIN RUSSWIN MFG: DETEX MFG: ADAMS RITE WALL STOP: (1) 409, US32D, RO L _I L _I L - J MFG: ROCKWOOD CYLINDER: 1080-118-A02-, 626, RU PADDLE (1) 4591-01-00, 628, AD SILENCER: (3) 608, RO MFG: CORBIN RUSSWIN OPERATOR: MFG: ADAMS RITE MFG: ROCKWOOD DOOR (1) CPS7500 SN -134, 689, NO CYLINDER: 1080-118-A03-, 626, RU CLOSER: MFG: NORTON MFG: CORBIN RUSSWIN HD -B: OFFICE LOCKSET \ HINGE: (3) TA714 4-1/2" X 4-1/2", US26D, MK THRESHOLD: (1) 1715AK, PE PUSH/PULL (1) BF15747 MTG-TYPE 1, MFG: MCKINNEY MFG: PEMKO BAR: US32D-316, RO CYLINDRICAL CL3551 NZD ACP, 626, RU GASKETING: (1) 2891AS TKSP8, PE MFG: ROCKWOOD LOCK: MFG: CORBIN RUSSWIN MFG: PEMKO DOOR (1) UN17500, 689, NO MFG: NORTON WALL STOP: (1) 409, US32D, RO RAIN GUARD: (1) 346C TKSP8, PE CLOSER: MFG: ROCKWOOD MFG: PEMKO DROP (1) 7786, 689, NO SILENCER: (3) 608, RO SWEEP: (1) 345ANB TKSP8, PE PLATE: MFG: NORTON MFG: ROCKWOOD HD C: UTILITY PASSAGE SET MFG: PEMKO NOTES: EXIT DEVICE WITH BUILT IN ALARM, BATTERY OPERATED KICK (1)K1050 10"x2" LDW 4BE CSK, PLATE: US32D, RO MFG: ROCKWOOD THRESHOLD: (1) 1715AK, PE HINGE: (3) TA714 4-1/2" X 4-1/2", US26D, MK HD -F: STORAGE SET MFG: PEMKO MFG: MCKINNEY CYLINDRICAL (1) CL3510 NZD, 626, RU HINGE: (1) TA714 4-1/2" X 4-1/2", US26D, MK MFG: MCKINNEY NOTES: PERIMETER WEATHER-STRIP SUPPLIED AND LOCK: MFG: CORBIN RUSSWIN INSTALLED BY THE ALUMINUM DOOR SUPPLIER. DOOR (1) 7500 SN -134, 689, NO SPRING (2) 1502 4-1/2" X 4-1/2", US26D, MK HD -J: BIFOLD SET CLOSER: MFG: NORTON HINGE: MFG: MCKINNEY / / 4, PE HWALL STOP: (1) 409, US32D, RO MFG: ROCKWOOD CYLINDRICAL (1) CL3510 NZD, 626, RU LOCK: MFG: CORBIN RUSSWIN SLIDING DOOR ) G MFG: O HDWE: M: P PEMKKO SILENCER: (3) 608, RO MFG: ROCKWOOD WALL STOP: (1) 409, US32D, RO DOOR PULL: (1) BF 107 MTG-TYPE 1, US32D, RO ■1111111111■■ MFG: ROCKWOOD MFG: ROCKWOOD HD D: BATHROOM PRIVACY SET SILENCER: (3) 608, RO MFG: ROCKWOOD ■■■■■1■■ HINGE: (3) TA714 4-1/2" X 4-1/2", US26D, MK HD -G: PASSAGE SET 2 MFG: MCKINNEY CYLINDRICAL (1) CL3510 NZD, 626, RU HINGE: (1) TA714 4-1/2" X 4-1/2", US26D, MK LOCK: MFG: CORBIN RUSSWIN MFG: MCKINNEY DOOR (1) 7500 SN -134, 689, NO SPRING (2) 1 502 4-1/2" X 4-1/2", US26D, MK CLOSER: MFG: NORTON HINGE: MFG: MCKINNEY WALL STOP: (1) 409, US32D, RO CYLINDRICAL (1) CL3510 NZD, 626, RU - MFG: ROCKWOOD LOCK (PASSAGE): MFG: CORBIN RUSSWIN ■■■■■■■■ SILENCER: (3) 608, RO MFG: ROCKWOOD WALL STOP: (1) 409, US32D, RO AMERICA'S BEST. MFG: ROCKWOOD SILENCER: (3) 608, RO iMMUQMMM MFG: ROCKWOOD VINYL TRANSITION, TR -1 VINYL COMPOSITION TILE CARPET LAWREN GROUP Austin Charlotte New York St. Louis 1 A6 TRANSITION DETAIL 3" = 1'-0" NOTE: GC TO VERIFY EXISTING CONDITIONS AT EXTERIOR DOOR(S). PROVIDE AND INSTALL HAGAR OR EQUAL SET OF PERIMETER WEATHER STRIPPING AND DOOR BOTTOM SEAL. IF DOUBLE DOORS, ALSO PROVIDE SET OF CENTER WEATHER STRIPPING. Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: DOOR THRESHOLD 1/2"MAX. HEIGHT + 1/4" - 1/2" 2 To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Professional Seal: 2 A6 TRANSITION DETAIL 3" = 11-0" Sim SIGNAGE PROVIDED BY AMERICA'S BEST SIGN CONTRACTOR ALL METAL PIPING SUPPLIED AND INSTALLED BY AMERICA'S BEST FIXTURE CONTRACTOR VERIFY FINAL FIXTURE & METAL PIPING SYSTEM SPECIFICATIONS & LOCATION NVI (PT4) \ / OPEN TO BEYOND ' k'11 ..-0,-- OPEN BEYOND 1� 8 i iy , N o 0 = 1 1 I C (P114) i I _ y i I L _I L _I L - J N= o (PT4) \ / OPEN TO BEYOND J■■■■■■■'■ o■1111■■■■■ J n (PT4) \ -- - BMW - - 1111 MIL nnnnr nnnn,-1nnnrE. II (IDT4) (PT4) �! �o - �o 00 �o o o o o 0ole,�n®I! o o 111111111-11111i111111.1111 _ ■■■■■■■■ ---1111-- _ ■■■■■■■■ 0 ROLLING FILE ■■11■■■■■ ■■■■■1111 ■1111ii■11■ ■UUIU■11. ■1111111111■■ CABINETS, SUPPLIED ■■■■■1■■ ■■■n■■■ ■■■■11■■ MEM ■■■■ AND INSTALLED BY ---- III!!iii 1111111111111111111s ■■■n■■'■ - - - ■■■■■■■■ Hill!!! AMERICA'S BEST. NUS in iMMUQMMM e■Ie, ■■■■■■■■ i■■■ii■■ ■■■■■■■■ ■■■■■■■■- 111111 ■1111■■■■ G o 11111111111111111111!I!!Ei• 1111■■■■■■ ■■■O■■■■ ■■■■■■■m ■■■■■■■■ mom sw■wi■■■-- t■■■■■■■ .--4- ■■■■■■i ■■■■■■■■ ii■nin■ ■■■n■ ■■■■■■■■ 1111■■■It 1111111111111111111.■■11■ ■' ■■■■■■■ = -- I1@00111 MINI ■■■■■■■■ F 1- _ I ■■■n■ ■■■11■■■■ (( (VB1) (vBl) 29 WALL MTD. CO N 0 0 VERIFY FINAL FIXTURE & METAL ALL METAL PIPING SUPPLIED PIPING SYSTEM SPECIFICATIONS AND INSTALLED BY AMERICA'S & LOCATION NVI r BEST FIXTURE CONTRACTOR (VB1) Project Title: TYP. TYP. 3 A6 ELEVATION - CONTACT LENS 1/4" = 11-0" 4 ELEVATION - DISPLAY A6 1/4" = 1'-0" Sim ALL METAL PIPING SUPPLIED AND INSTALLED BY AMERICA'S BEST FIXTURE CONTRACTOR SIGNAGE PROVIDED BY AMERICA'S I Y 1a O` N ZO I 0' (P114) ` E') rn C L _I L _I L - J N= o (PT4) \ / J n (PT4) \ -- BMW (IDT4) (PT4) 1111-- 111111111-11111i111111.1111 _ ---1111-- _ ■■■■1111■ 0 ROLLING FILE ■■11■■■■■ u ■UUIU■11. ■1111111111■■ CABINETS, SUPPLIED ■■■■■1■■ ■■■■11■■ ■■■■ AND INSTALLED BY III!!iii 1111111111111111111s - - - - - Hill!!! AMERICA'S BEST. NUS in iMMUQMMM 1111■i■ ■■■■■■■■ i■■■ii■■ ■■■■■■■■ 111111 ■1111■■■■ G o 11111111111111111111!I!!Ei• 1111■■■■■■ ■■■■■■■m mom t■■■■■■■ .--4- ■■■■■■i 4' 0 ■■■n■ ■■■■■■■■ 1111■■■It 1111111111111111111.■■11■ ■' ■■■■■■■ = I1@00111 MINI ■■■■■■■■ F 1- _ ■■■n■ ■■■11■■■■ (( 1111■■■■■ ■■■■■■■■ N(•■■■1■ 1111■■■■■ L 11111111.1111 111111!! li J - m,. _II11■■I: ■■■n■ i MIMI 6" 4' - 0" 6" zo ■n■■■■■■ MUM - N ■nnn■ - ■1111■■■■■ \ U!■!■■■t M11■■■■■ ■11Un■ ■■■■■1111■ II1■■■I1 ■■■■■■■■ moon■■ ■■■111■■ ■■ii■■ii ■iiiini 1111■11■■ iiinn■ii ®iil®o®n 0 0 o p o 0 0 0 0 0 \ \ i V (VB1) Project Title: TYP. TYP. 3 A6 ELEVATION - CONTACT LENS 1/4" = 11-0" 4 ELEVATION - DISPLAY A6 1/4" = 1'-0" Sim ALL METAL PIPING SUPPLIED AND INSTALLED BY AMERICA'S BEST FIXTURE CONTRACTOR SIGNAGE PROVIDED BY AMERICA'S I Y O` --`- L _ 1 F 1 1 1 I I 0' InL ` E') rn C L _I L _I L - J N= o (PT4) \ / J (PT4) \ BMW (IDT4) (PT4) 111111111-11111i111111.1111 _ _ ■■■■1111■ 0 ROLLING FILE ■■11■■■■■ ■1111111111■■ CABINETS, SUPPLIED ■■■■■1■■ ■■■■11■■ AND INSTALLED BY III!!iii - - - -- - - - Hill!!! AMERICA'S BEST. NUS in iMMUQMMM ■■■■■■■■ ■■■■■■■■ ■■■■■17 ■1111■■■■ G o 1111■■■■■■ ■■■■■■■m mom t■■■■■■■ .--4- 4' 0 ■■■■■■■■ 1111■■■It ■' ■■■■■■■ = I1@00111 MINI II91 F 1- _ ■■■11■■■■ (( ■■■■■■■■ N(•■■■1■ 1111■■■■■ L li - m,. _II11■■I: i 6" 4' - 0" 6" zo N N \ VB1 "RECEPTION" TEXT ON COUNTER FASCIA PROVIDED AND NSTALLED BY AMERICA'S BEST VENDOR. INDICATED PORTION OF THE COUNTER AT THE SERVICE AREA SHALL BE NO MORE THAN 34" IN HEIGHT FOR USE BY AN ENVIRONMENTALLY LIMITED PERSON OR EMPLOYEE. (VB1 0 0 VERIFY FINAL FIXTURE & METAL ALL METAL PIPING SUPPLIED ALUM. & GLASS PIPING SYSTEM SPECIFICATIONS AND INSTALLED BY AMERICA'S S-OREFRONT & LOCATION NVI - BEST FIXTURE CONTRACTOR ,- S°STEM BEYOND To r\\ N [ --- __ (PT4) \ / J \ BMW 111111111-11111i111111.1111 _ _ ■■■■1111■ 0 ■■11■■■■■ ■1111111111■■ ■■■■■1■■ ■■■■11■■ III!!iii - - - -- - - - Hill!!! NUS in iMMUQMMM ■■■■■■■■ ■■■■■■■■ ■■■■■17 ■1111■■■■ G 1111■■■■■■ ■■■■■■■m mom t■■■■■■■ insmo- ■■■■■■■■ ■■■■■■■■ 1111■■■It ■' ■■■■■■■ = I1@00111 MINI II91 F 1- _ ■■■11■■■■ ■■■■■■■■ N(•■■■1■ 1111■■■■■ - m,. _II11■■I: i TYP. TYP. 5 A6 ELEVATION - RECEPTION 1/4" = 1'-0" 6 A6 ELEVATION - STOREFRONT 1/4" = 11-0" P-6: SEE PLUMBING SCHEDULE, FOR SPECS 0 eo 0 0 v 00 co z N J 0 C7 z J w 0 0 I- CC 0 O J 0 Ecq 39"-41" 54" MIN 18" VERTICAL GRAB BAR (IF REQUIRED) F.R.P. TO 48" A.F.F. 1 1/2" DIA. GRAB BAR NOTE: FLUSH VALVE ON WIDE SIDE OF TOILET MOUNTED 44" A.F.F. MAX. GOOSENECK FAUCET & WRIST BLADES: SEE PLUMBING DRAWINGS FOR SPECIFICATIONS 12" MIN. 1 1/2" DIA. GRAB BAR MIRROR TO BE MOUNTED AT A MAXIMUM OF 40" AFF TO THE BOTTOM OF THE REFLECTIVE SURFACE; MIRROR PROVIDED & INSTALLED BY GC. PAPER TOWEL AND SOAP DISPENSER PROVIDED AND INSTALLED BY NVI 3'-6" 1'- f TISSUE DISPENSER f 4--7"-9" 0.C. PROVIDED AND INSTALLED BY NVI F.R.P. TO 48" A.F.F. ACCESSIBLE SINK TO BE AT NO MORE THAN 34" TO THE RIM OF THE SINK OR LAVATORY INSULATE HOT WATER SUPPLY & DRAIN REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date Sheet Title: 7 ELEVATION 8 ELEVATION 9 ELEVATION RECEIVED CITY OF TUKWILA PERMIT-CENTER- Sheet ERMIT CENTER Elevations/Details P r'ect N A6 1 /411 = 1'-0" A6 1/4" = 11-0" A6 1/4" = 1'-0" Issue Da 06/22/ Sheet Number: A6 C:\Users\areinhardt94\Documents\pin_17903 029 areinhardt94.rvt co 0) 0 0 N co c\v 2 0 0_ U, NO. 10 TIE WIRE 3-5/8" 25 GA. MTL. STUD. BRACE PLACED ON ALTERNATING SIDES OF WALL AT 48" O.C., MIN. TWO PER WALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF STRUCTURAL DECK OR BEAM ABOVE. PARTITION 1 ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE CEILING PLAN FOR LAYOUT. TOP RUNNER (1) LAYER 5/8" TYPE -X GYP. BD. EACH SIDE OF 3-5/8" 20 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES CONTINUOUS 3-5/8" 25 GA. MTL. RUNNER. FASTEN USING 0.140" DIA. x 3/4", EMBED AT 16" O.C. BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED 4 7/8" PARTITION A6.1 1 1/2" = 1'-0" NO. 10 TIE WIRE i Co 3-5/8" 25 GA. MTL. STUD. BRACE PLACED ON ALTERNATING SIDES OF WALL AT 48" O.C., MIN. TWO PER WALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF STRUCTURAL DECK OR BEAM ABOVE. 2 PARTITION ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE CEILING PLAN FOR LAYOUT. TOP RUNNER (1) LAYER 5/8" TYPE -X GYP. BD. EACH SIDE OF 3-5/8" 20 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES 3" OF 2.5#/CF SOUND ATTENUATION BATT INSULATION OF FIBERGLASS CONTINUOUS 3-5/8" 25 GA. MTL. RUNNER. FASTEN USING 0.140" DIA. x 3/4", EMBED AT 16" O.C. BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED 4 7/8" PARTITION A6.1 1 1/2" = 1'-0" NOTE: USE CONSTRUCTION ADHESIVE TO TO ADHERE THE ENTIRE BOTTOM PLATE TO THE FLOOR AND SHOOT IN/PIN IT EVERY 1'-0". USE ONE PIECE OF DRYWALL TO CUT OUT THE TOP PIECE OF WALL. 9" 3" 4" 3" / 0 i , 2" ANCHOR BOLT LOCATION, TYP. 0 0 0 I o @ 7'-6" A.F.F. (HOLD) SECURE 5/8" GYP. - BD. TO 3 5/8" TUBE STL. (T.O. STL. 7'-0") 1/8" STEEL TUBE WELDED TO BASE lI�I=� SCHEDULEDOISH AS PLATE 1 /8" BASE PLATE 1/8" STEEL TUBE 1/8" STEEL BASE PLATE NOTE: SEE CONSTRUCTION PLAN FOR STEEL PLATE & TUBE LOCATIONS (1) LAYER 5/8" TYPE -X GYP. BD. EACH SIDE, AND TOP, OF 3-5/8" 20 GA. MTL. STUDS AT 16" O.C.-PROVIDE CORNER BEAD, TAPE, SPACKLE, AND SAND TO READY FOR FINISHES BASE AS SCHEDULED SEALANT EXISTING CONC. SLAB 3 PARTITION PARTIAL HEIGHT A6.1 1 1/2" = 11-0" SECURE 1/8" BASE PLATE TO EXISTING CONC. SLAB W/ 2" ANCHOR BOLTS USE ICC#ESR-2508 (LARR#25744), OR EQUAL. NO. 10 TIE WIRE ►i 3-5/8" 25 GA. MTL. STUD. BRACE PLACED ON ALTERNATING SIDES OF WALL AT 48" O.C., MIN. TWO PER WALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF STRUCTURAL DECK OR BEAM ABOVE. 4 PARTITION ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE CEILING PLAN FOR LAYOUT. TOP RUNNER (1) LAYER 5/8" TYPE -X GYP. BD. EACH SIDE OF 3-5/8" 20 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES 3" OF 2.5#/CF SOUND ATTENUATION BATT INSULATION OF FIBERGLASS (WHERE INDICATED ON CONSTR. PLAN) CONTINUOUS 3-5/8" 25 GA. MTL. RUNNER. FASTEN USING 0.140" DIA, x 3/4", EMBED AT 16" O.C. BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED 4 1/4" FURRING A6.1 1 1/2" = 1'-0" NO. 10 TIE WIRE 3-5/8" 25 GA. MTL. STUD. BRACE PLACED ON ALTERNATING SIDES OF WALL AT 48" O.C., MIN. TWO PER WALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF STRUCTURAL DECK OR BEAM ABOVE. ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE CEILING PLAN FOR LAYOUT. (OFFICE SIDE) @ 10'-0" A.F.F. TOP RUNNER i 5 PARTITION (RESTROOM SIDE) @ 8'-0" A.F.F. (1) LAYER 5/8" TYPE -X GYP. BD. EACH SIDE OF 3-5/8" 20 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES 3" OF 2.5#/CF SOUND ATTENUATION BATT INSULATION OF FIBERGLASS CONTINUOUS 3-5/8" 25 GA. MTL. RUNNER. FASTEN USING 0.140" DIA. x 3/4", EMBED AT 16" O.C. BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED RESTROOM PARTITION A6.1 1 1/2" = NO. 10 TIE WIRE z 0 z 0 z 0 Lu rr w 2 z 0 U F z 0 0 I— z w 0 0 Co — 6 PARTITION ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE CEILING PLAN FOR LAYOUT. (1) LAYER 5/8" TYPE -X GYP. BD. ONE SIDE OF 1-5/8" 20 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED 2 1/4" FURRING A6.1 1 1/2" = 1'-0" "r 81 (0 NO. 10 TIE WIRE 3-5/8" 25 GA. MTL. STUD, BRACE PLACED ON ALTERNATING SIDES OF WALL AT 48" O.C., MIN. TWO PER WALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF STRUCTURAL DECK OR BEAM ABOVE. /2" 7 PARTITION ACOUSTICAL CEILING TILE AND GRID SUSPENDED FROM ABOVE. SEE REFLECTED CEILING PLAN FOR LAYOUT. (1) LAYER 5/8" TYPE -X GYP. BD. BOTH SIDES OF (2) 3-5/8" 25 GA. MTL. STUDS AT 16" O.C. TAPE, SPACKLE, AND SAND READY FOR FINISHES (2) LAYERS OF 3" OF 2.5#/CF SOUND ATTENUATION BATT INSULATION OF FIBERGLASS (ONLY WHERE INDICATED ON CONSTRUCTION PLAN) (2) CONTINUOUS 3-5/8" 25 GA. MTL. RUNNER. FASTEN USING 0.140" DIA. x 3/4", EMBED AT 16" O.C. BASE AS SCHEDULED SEALANT FLOOR FINISH AS SCHEDULED SOUND PARTITION A6.1 1 1/2" = 1'-0" LAWREN GROUP Austin Charlotte New York St. Louis Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 Professional Seal: J L) Project Title: America's Best Contacts & Eyeglasses The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, Instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2011 RFCEIVED CITY OF TUKWII A JUL 14 2017 HERMIT CENTER Sheet Title: Partition Types Pro] mber: 17 .029 06 f4,+017 Sheet Number: p6.1 C:1Users\areinhardt94\ Documents \pin_17903_029 areinhardt94.rvt ACCESSIBILITY KEYED NOTES 701 AT SALES AND SERVICE COUNTERS, AT LEAST ONE OF EACH TYPE SHALL HAVE A PORTION OF COUNTER THAT IS AT LEAST 36" IN LENGTH AND 36" MAXIMUM HEIGHT FOR A PARALLEL APPROACH AND A PORTION OF COUNTER THAT IS AT LEAST 30" IN LENGTH AND 36" MAXIMUM HEIGHT FOR A FORWARD APPROACH TO COMPLY WITH SECTION 904 OF ANSI A117.1 FOR USE BY AN ENVIRONMENTALLY LIMITED PERSON OR EMPLOYEE. IF A FORWARD APPROACH IS USED, A CLEARFLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A FORWARD APPROACH TO THE ACCESSIBLE COUNTER, SHALL BE PROVIDED, KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED UNDER THE ACCESSIBLE COUNTER.*FURNITURE SHOWN BY DESK IS MOVEABLE, NOT PERMANENT.* 702 SEE ELEVATION 5/A6 FOR COUNTER/SERVICE AREA IN THIS AREA TO HAVE A PORTION OF COUNTER THAT IS AT LEAST 36" IN LENGTH AND 36" MAXIMUM HEIGHT TO COMPLY WITH SECTION 904 OF ANSI A117.1 FOR USE BY AN ENVIRONMENTALLY LIMITED PERSON OR EMPLOYEE. *FURNITURE SHOWN BY DESK IS MOVEABLE, NOT PERMANENT.* 703 SINKS REQUIRED TO BE ACCESSIBLE BY ANSI SHALL BE ACCESSIBLE PER ANSI A117.1 SECTION 606. SECTION 606 LAVATORIES AND SINKS - MUST PROVIDE 34" COUNTER HEIGHT, A KNEE CLEARANCE 27" HIGH BY 30" WIDE BY 19" DEEP UNDER SINK. SINK IS MAXIMUM 6.5" DEEP WITH CLEAR FLOOR SPACE OF 30" X 48" IN FRONT OF SINK FOR A FORWARD APPROACH. CLEAR FLOOR SPACE TO BE A MAXIMUM OF 19' UNDER SINK. INSULATE EXPOSED DRAIN PIPES AND PROVIDE FAUCET WITH LEVER HARDWARE AND ALL OTHER REQUIREMENTS OF THIS SECTION. KNEE AND TOE CLEARANCE SHALL BE PROVIDED PER SECTION 306. TOE CLEARANCE SHALL EXTEND 25" MAX. AND 17" MIN. UNDER AN ELEMENT FOR A HEIGHT OF AT LEAST 9" A.F.F. KNEE CLEARANCE SHALL EXTEND 8" MIN. UNDER AN ELEMENT FOR A HEIGHT OF 27" MIN AND 11" MIN. UNDER AN ELEMENT FOR A HEIGHT OF 9" MIN. 704 THIS AREA REPRESENTS A PARALLEL APPROACH 30" X 48" CLEAR FLOOR SPACE. 705 THIS AREA REPRESENTS A FORWARD APPROACH 30" X 48" CLEAR FLOOR SPACE. 706 RESTROOM SIGNAGE SHALL BE PROVIDED & INSTALLED BY GC IN ACCORDANCE WITH ALL SECTIONS OF 703. REGARDING HEIGHT OF SIGNAGE, SEE SECTION 703.4.5 MOUNTING HEIGHT. LAWREN GROUP 1'1" Austin Charlotte New York St. Louis 34" HIGH (MAX.) SURFACE SHALL BE 36" LONG (MIN.) 2'-1" / 24" MAX. SCHEDULED SINK, 6.5" DEEP MAX z 2 1'-7" Office: 319 N. Fourth Street St. Louis, MO 63102 p 314-231-5700 f 314-231-0816 MAX. 2 48" MIN. CLEAR FLOOR SPACE 30" MIN. jGCLEAR FLOOR SPACE Project Team: General Contractor: Project Manager: MEP Engineer: To Be Selected Cushman & Wakefield Contact: Christine Campbell 314.392.2617 Schnackel Engineers, Inc. Contact: Mike Kilgore 402.391.7680 SECTION AT SINK 3 A7 1/2" = 1'-0" A7 SECTION AT SIDE APPROACH COUNTER 1/2" = 1'-0" Professional Seal: Project Title: r ■ ■ Reception/Dispense 100 702 704 —' L J J Q Supply 113 / \ Men's _Restooni 106 1 I/ N Manager's Office 110 I Supply 115 J N / Women's \ Festroom_ 107 / / / / Contact Lens L 102 ►I L 17061 -71 I 706 r 1 r 1 705 705 0 I I fl 1 701 r I L 703 705 L_ 704 3'-0" MIN. TYP. L I I Waiting 109 IL II J L J Mechanical 116 Display 101 J rwellrrrrr-rr •rrPr • • IIPArrrrr Pre -Consult 103 Pre -Consult 104 Consult 111 Consult 112 Breakroom 108 1 1 -i 0 co z 2 703 705 703 705 703 705 J L L J L J 1 11 I Ll 11 1 INN 1111 U-.-' VI i7474 . r 0 " 0 XXXXXXYXXXX`,IXYYXXXXYXXXXXYXXXXYYYX .. ♦• XYXXXXXXXXYYX REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2017 U) U) a) a W CLS 0 U Ma) W U) 0 a) E a) U a co >, LO ccs co The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal. This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect. No. Description Date Sheet Title: RECEIVED CITY OF TUKWILA JUL 1 4 2017 PERMIT CEN i E? Accessibility/Life Safety Plan ject Number: 903.029 1 LIFE SAFETY PLAN A7 1/4" = 1'-0" ue Date: /22/2017 Sheet Number: Al