Loading...
HomeMy WebLinkAboutPermit D17-0201 - KING COUNTY DCHS WORKSOURCE - TENANT IMPROVEMENTKING COUNTY DCHS WORKSOURCE 645 ANDOVER PARK W Dl 7-0201 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 2623049143 Permit Number: D17-0201 645 ANDOVER PARK W BLDG 6 Project Name: KING COUNTY DCHS WORKSOURCE Issue Date: 9/29/2017 Permit Expires On: 3/28/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOUTHCENTER CORPORATE SQUAR 635 ANDOVER PARK W #107 , TUKWILA, WA, 98188 SHANE SMITH 119 S MAIN ST, SUITE 400 , SEATTLE, WA, 98104 GATEWAY CONSTRUCTION SRVCS INC 5602 2ND AVE S , SEATTLE, WA, 98108-2409 GATEWCS992C3 SOUTHCENTER CORPORATE SQUAR 635 ANDOVER PARK W #107 , TUKWILA, WA, 98188 Phone: (206) 946-9651 Phone: (206) 621-9111 Expiration Date: 3/4/2018 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT TO (20 FLOORS INVOLVING MINOR WALL DEMOLITION, NEW PARTITIONS, LIGHTING AND FINISHES. Project Valuation: $589,650.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $9,604.45 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 a Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: l Date: 61-? -? —/ -17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe,,�m%t and agree to the f onditions attached to this permit. Signature: Print Name: Ck1(-e4 rigs k-111 Date: 177-5' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 10: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1013.1) 11: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1013.6.1) 12: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 13: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1013.6.3) 14: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1008.3.5) 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 19: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 27: ***BUILDING PERMIT CONDITIONS*** 28: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 29: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 30: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 31: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 32: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 33: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 34: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 35: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 36: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 37: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 38: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 39: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKR�,e,��A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Pert No. 11" 044 I Project No. Date Application Accepted: Date Application Expires: (For office use only) fAitg CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 645 Andover Park West, bldg 6 Tenant Name: King County DCHS Worksource 501AflLQ.*Y COY ()Yak, S9una t, PROPERTY OWNER Name: PinTratt-Property-Managemunt Address: 635 Andover Park West, Suite 107 City: Tukwila State: WA Zip: 98366 CONTACT PERSON — person receiving all project communication Name: Shane Smith Address: 119 S. Main St., Suite 400 City: Seattle State: WA Zip: 98104 Phone: (206) 946-9651 Fax: Email: ssmith@wja-dc.com GENERAL CONTRACTOR INFORMATION Company Name: TBD After Project is Bid Address: Address: 119 S. Main St., Suite 400 City: Seattle State: WA Zip: 98104 Phone:(206) 946-9746 Fax: City: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \201 I ApplicationstPemvt Application Revised - 8-9-11.docx Revised: August 2011 bh King Co Assessor's Tax No.: Suite Number: Floor: 1 &2 New Tenant: ® Yes ❑ ..No ARCHITECT OF RECORD Company Name: WJA - design collaborative Architect Name: Greg Nespor Address: 119 S. Main St., Suite 400 City: Seattle State: WA Zip: 98104 Phone:(206) 946-9746 Fax: Email: gnespor@wja-dc.com ENGINEER OF RECORD Name: . 061fi/1()o(4-ry Co1/(1)o6tk 5/maie1I_I, Address: (12,5s_ v tAiQx ?el v....uu. Su►k t(fl Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: . 061fi/1()o(4-ry Co1/(1)o6tk 5/maie1I_I, Address: (12,5s_ v tAiQx ?el v....uu. Su►k t(fl City:—TvAciAj `IA State: f , , A.. Zip: c b( N Page 1 of 4 BUILDING PERMIT INFORMATIO006-431-3670 Valuation of Project (contractor's bid price): $ 589,650 (ESTIMATED) Describe the scope of work (please provide detailed information): Existing Building Valuation: $ i> -r Jv-�.� ) f.,1 f / C a ��� �,-�n-a2 11-1,� w�v�, �` �f;bT r i Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide AH Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: EJI Sprinklers 121 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\201 I Applcations\Pennit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC ls` Floor 9,936 8,654 0 V -B B 2nd Floor 100,855 9,441 0 V -B B 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage — Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: EJI Sprinklers 121 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\201 I Applcations\Pennit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 (PERMIT APPLICATION:NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Shane M Smith Mailing Address: 119 S. Main St. Suite 400, Seattle WA, 98104 H:\Appliwlions\Forms-Applications On Line\201 I Applications\Pcrmit Application Revised - 8-9-11.dacx Revised: August 2011 bh Day Telephone: (206) 946-9651 City State Zip Page 4 of 4 DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY ? PAID '$5,933.88 D17-0201 Address: 645 ANDOVER PARK W BLDG 6 Apn: 2623049143 $5,933.88 DEVELOPMENT $5,651.53 PERMIT FEE R000.322.100.00.00 0.00 $5,647.03 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $282.35 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R12366 $282.35 $5,933.88 Date Paid: Wednesday, September 20, 2017 Paid By: WJA - DESIGN COLLABORATIVE Pay Method: CHECK 7359 Printed: Wednesday, September 20, 2017 12:44 1 of 1 PM CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $3,670.57 $3,670.57 $3,670.57 $3,670.57 $3,670.57 D17-0201 Address: 645 ANDOVER PARK W BLDG 6 Apn: 2623049143 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12010 R000.345.830.00.00 0.00 Date Paid: Friday, July 28, 2017 Paid By: WJA INC Pay Method: CHECK 7280 Printed: Friday, July 28, 2017 10:18 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 b 7-0"W/ Pro'ect: {• e. 2/3 pieNKsWRc Type of Inspection: Bu/Ni- i I NAL Address:Date 6y5-- itN/OVER PAA A Called: Special Instructions: r- & Date Wanted: t -X - l 5-. 17 a.m. pETn: Requester: Phone No: NIApproved per applicable codes. Corrections required prior to approval. COMMENTS: c3K - Aort-D/AIGG i<"0•61-1_ Inspector: ` Nk&- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DI -7- OP -43 I Project: Kiii.I~Y COtf De)40 Woleksovget Type of Inspection: Address: (S5 /9/l' SR ARR l c1 Date Called:. Special Instructions: 6 -Ce Date Wanted: 1).-11-17 a.r . p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: c K- criAz N( - Inspector: Date: 12-1/ _/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 'KC, D c H-5 w K sates Type of Inspection: s u s pOND(A //. A& - Address: &I/5— bV#/R PARK PO Date Called: Special Instructions: Date Wanted: f Date �/ / Ca.m� p.»: Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: pfZ-SU5P 049 1../N nspector: Date: LZ -17 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Dt7-eexo1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: KIR& &®� t/ I s Type of Inspection: -i 6../P AM Address: ja.30 Sa)11:14e 45 "VDOVTA PIRRK V. -)a Date Called: ,--re Special Instructions:Date % Wanted: ��� i 7 (-a.m.)31.17& p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: , f l6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dt7-O/ Project: Rlrt4- eoUNTY Dc HS iA) RK olit Type of Inspection: riel-M IN16- Address: 6.5- i4R&bkal Date Called: Special Instructions: 4£-D6- 6, C'rLL W N OP -577E Date Wanted: IO —2O ,-t 7 p.m. Requester: Phone No: 20(e- 7 87- exp 40 / UApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 8 - /wt.rbt G- -se ctAf 4. E.,./cira W`_"_L-LS Inspector: Date: fo-2-0--/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1 OZ-' 1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT. 206-575-4407 Project: --/y.i4c Type ofInspection: Fire Alarm: /4-,z4 Address:,,Contact Suite #: 6Ys A 11A) Person: ✓ / / ' ) Special Instructions: ��iK w--, -� s Phone No.: .,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: iT , fI I 7 - 1 ��iK w--, -� s (/,)/ ' / C. d ? \ 16 --to Add �tc� - - C/a -Se/ 615;-1,1_70w:d A 5e,,z," ,4-,c7i,:,,, .;: --6t,40.1,,_ rt v2i64d de (.J 0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ., /W/ 3 Date: / 2...11 /// 7 Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit i - F - 2oS X17- Ute( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: - . Fire Alarm: Type of Inspec%tion: _ 5e /----'--4_. / 7 Address: Suite #: 06% 2� Occupancy Type: Contact Person:` / /Oak) Special Instructions: k Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Cave )1-// Ade/a--e" Guar/ %, � 04 C ff/ ,,7^-#4 / — (" Needs Shift Inspection: Sprinklers: - . Fire Alarm: Hood & Duct: Monitor: Pre -Fire: _ Permits: Occupancy Type: Inspector: > 1 Date: /2-hz_n 7 Hrs.: / 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit i re -02.1/ PERMIT PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: b Li s Sprinklers: Type of Inspection: Gevt- Address: 4-5-- Suite #: (2 ft12 / Contact Person: Special Instructions: Occupancy Type: Phone No.: \,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: PMiT1 ill- 6-0 YE12--- e j2 .1 r�� 4_ X2)9-5 C-&- Occupancy Type: ?t -?if" - c: --).J0 o / 41,v im EL re Go P ii --a t-1QtJ cP 1--1--ir- ilt-712-4--re.•/7-c 7W/2 -0/67/-(e' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:-yi,k. ' --- Date: 1�/4// - Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 August 16, 2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development SHANE SMITH 119 S MAIN ST, SUITE 400 SEATTLE, WA 98104 RE: Correction Letter # l DEVELOPMENT Permit Application Number D17-0201 KING COUNTY DCHS WORKSOURCE - 645 ANDOVER PARK W, BLDG 6 Dear SHANE SMITH, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. I could not find where a drinking fountain is provided in this building. Show an accessible drinking fountain on each floor of this building. (IBC 2902.5.1 WSA) Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Bill Rambo Permit Technician File No. D17-0201 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 C Joanna Spencer From: Todd Reedy Sent: Monday, July 31, 2017 1:11 PM To: Joanna Spencer Subject: RE: 645 APW Bldg #6 Hi Joanna, 645 APW is current on backflow preventer installation and testing. Have a great day, Todd From: Joanna Spencer Sent: Monday, July 31, 2017 11:19 AM To: Todd Reedy <Todd.Reedy@TukwilaWA.gov> Cc: David McPherson<David.McPherson@TukwilaWA.gov>; Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> Subject: 645 APW Bldg #6 Good Morning Todd, Are their backflows current? Joanna Spencer Development Engineer Public Works Department 6300 Southcenter Blvd, Suite 100, Tukwila, WA 98188-2544 Phone: 206 431-2440 Fax: 206 431-3665 1 D)7'O2oi CERMfi COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0201 DATE: 08/28/17 PROJECT NAME: KING COUNTY DCHS WORKSOURCE SITE ADDRESS: 645 ANDOVER PARK W Original Plan Submittal i• Response to Correction Letter # I Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Aug, Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/29/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/26/17 Approved Approved with Conditions Corrections Required ❑ Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 C5 PERMIT COORD COPY.. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0201 DATE: 07/28/17 PROJECT NAME: KING COUNTY DCHS WORKSOURCE SITE ADDRESS: 645 ANDOVER PARK W, BLDG 6 X Original Plan Submittal Response to Correction Letter #_ Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT C MZ «1 Building Division `���/J c NDS 'PubliWorks411 AA 'NC 0-44 � Al° B -1—c% Fire Prevention Planning Division Structural Orr Permit Coordinator ❑ PRELIIMIINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 08/01/17 Structural Review Required DATE: 111 APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 08/29/17 111 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL` Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: a -•e). ti Plan Check/Permit Number: D17-0201 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued RECEIVED CITY OF TUKWILA AUG 2 4 2017 ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Name: King County DCHS Worksource Project Address: 645 Andover Park W Contact Person: L Phone Number: 10 6 .q11‘ •�6� Summary of Revision: EkrvTCF- 1AIWk.i£ 13 E+1)Asrre'tg.9 4t C C�'as� Eo t���_ 1 Ne/• Coe.-r0.1s co,tt.A..x Sheet Number(s): NV1151. ADI OS t A-�nl ,4-163 "Cloud" or highlight all areas of revision including rdate �oof revision Received at the City of Tukwila Permit Center by: U1✓► wl CN Ork,f9 ❑ Entered in TRAKiT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: GATEWAY CONSTRUCTION Smcy INC Horne. Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & industries Search L&I Page 1 of 2 A -Z index Help Icly L` I Workplace Rights Trades & Licensing GATEWAY CONSTRUCTION SRVCS INC Owner or tradesperson Principals SACCO, RONALD, PRESIDENT • NIELSEN, CRISTIAN, VICE PRESIDENT Doing business as GATEWAY CONSTRUCTION SRVCS INC WA UBI No. 602 086 011 5602 2nd Ave. S. SEATTLE, WA 98108 206-621-9111 KING County Business type Corporation Governing persons CRIS J NIELSEN CHARLES J PORTER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. GATEWCS992C3 Effective — expiration 02/26/2001— 03/04/2018 Bond Berkley Insurance Co Bond account no. 0193811 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/25/2015 08/19/2015 Expiration date Until Canceled TRAVELERS CAS & SURETY CO Bond account no. 105165492 $12,000.00 Received by L&I Effective date 08/21/2008 08/19/2008 Expiration date Until Canceled Insurance ..................._....... Charter Oak Fire Ins Co $1,000,000.00 WA -0 efq 144 E.> Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602086011 &LIC=GATEWCS992C3&SAW= 9/29/2017 GATEWAY CONSTRUCTION SR,v,CS INC Policy no. DTC0527D0333C0F17 Received by L&I Effective date 07/26/2017 08/01/2017 Expiration date 08/01/2018 Insurance history Savings ............ No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 12-2-03868-4 Complaint filed by BUILDERS MILLWORK SUPPLY Complaint date 03/28/2012 Dismissed ................................ Complaint against bond(s) or savings 105165492 Complaint amount $11,763.88 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 007,541-00 ................................ Doing business as GATEWAY CONSTRUCTION SERVICES Estimated workers reported Quarter 2 of Year 2017 "51 to 75 Workers" L&I account contact T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/07/2015 Inspection no. 317936013 Location 14810 Puyallup Street Sumner, WA 98390 Violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602086011 &LIC=GATEWCS992C3&SAW= 9/29/2017 7/27/2017 1:29:40 PM Sheet Size: 22"x34" (24"x36") S WORKSOURCE 645 ANDOVER PARK WEST, BLDG. 6 KWILA, WA CO TRACT #: E00380E15 WORK ORDER #: CA -0414 CLIENT : KING COUNTY DEPARTMENT OF COMMUNITY AND HEALTH SERVICES PROJECT DESCRIPTION • SEPARATE PERMIT REQUIRED FOR: ochanlcal Electrical Ll(filumbing Ie'Gas Piping Cit; of Tukwila BUI'IWiNG ENVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: revisions will require a new plan submittal and may include additional plan review fees. INTERIOR TENANT IMPROVEMENT OF A TWO STORY 20,000SF OFFICE BUILDING FOR THE USE OF THE DCHS WORKSOURCE OFFICE, TO INCLUDE PROGRAM SPACE FOR THE KING COUNTY VETERANS, EMPLOYMENT, AND EDUCATION RESOURCES PROGRAMS. PROGRAM AREA WILL INCLUDE, OFFICE AND ADMINISTRATIVE SPACE FOR EACH PROGRAM, SECURE FILE STORAGE, IN ADDITION TO SHARED CONFERENCE AND MEETING SPACES, CLASSROOM AND COMPUTER RESOURCE AREAS AND TRAINING SPACES. SHEET INDEX Sheet Number Sheet Name A-602 FLOOR, WALL & CEILING ASSEMBLIES 0001 - GENERAL G-001 COVER SHEET G-002 FIRST FLOOR CODE PLAN G-003 SECOND FLOOR CODE PLAN 0002 - ARCHITECTURAL A-001 ARCHITECTURAL GENERAL NOTES AND LEGENDS A-002 ACCESSIBILITY DETAILS AD101 FIRST FLOOR DEMOLITION PLAN - WEST AD102 FIRST FLOOR DEMOLITION PLAN - EAST AD103 SECOND FLOOR DEMOLITION PLAN - WEST AD104 SECOND FLOOR DEMOLITION PLAN - EAST AD111 FIRST FLOOR DEMOLITION RCP - WEST AD112 FIRST FLOOR DEMOLITION RCP - EAST AD113 SECOND FLOOR DEMOLITION RCP - WEST AD114 SECOND FLOOR DEMOLITION RCP - EAST A-101 FIRST FLOOR PLAN - WEST A-102 FIRST FLOOR PLAN - EAST A-103 SECOND FLOOR PLAN - WEST A-104 SECOND FLOOR PLAN - EAST A-111 FIRST FLOOR REFLECTED CEILING PLAN - WEST A-112 FIRST FLOOR REFLECTED CEILING PLAN - EAST A-113 SECOND FLOOR REFLECTED CEILING PLAN - WEST A-114 SECOND FLOOR REFLECTED CEILING PLAN - EAST A-401 INTERIOR ELEVATIONS A-501 DETAILS A-502 TYPICAL ACT DETAILS A-601 DOOR SCHEDULES & LEGENDS SITE STREET VIEW: SHEET INDEX Sheet Number Sheet Name 0004 - MECHANICAL M-000 LEGEND, ABBREVIATIONS & NOTES M-001 HVAC SCHEDULES MD -101 FIRST FLOOR PLAN - HVAC DEMO MD -102 SECOND FLOOR PLAN - HVAC DEMO M-101 FIRST FLOOR PLAN - HVAC M-102 SECOND FLOOR PLAN - HVAC M-103 ROOF PLAN - HVAC M-400 SEQUENCE OF OPERATIONS AND POINTS LIST M-500 HVAC DETAILS 0005 - PLUMBING P-000 LEGEND, ABBREVIATIONS & NOTES P-001 PLUMBING SCHEDULES PD -101 FIRST FLOOR PLAN - PLUMBING DEMO PD -102 SECOND FLOOR PLAN - PLUMBING DEMO P-101 FIRST FLOOR PLAN - PLUMBING P-102 SECOND FLOOR PLAN - PLUMBING 0006 - FIRE PROTECTION SITE MAP PROJECT SITE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 �,� f,D �/- J1T Clty of Tukwila BUILD! • >* 370 5. 9144' 360 5 4;65 tsarpo to CirN 1715 0 ohf s` PETE 17200 rp { 110RDSSr l 5 • 9075, VICINITY MAP PROJECT SITE FILE COPY Permit No. ��]020 Plan review approve! is subject to errors and orris Approval of construction documents does not a he violation of any adopted or ordinance, R f approved Fiel Copy and con lMona acknowl FP -000 LEGEND, ABBREVIATIONS & NOTES E0.2 FP -101 FIRST FLOOR PLAN - FIRE PROTECTION t FP -102 SECOND FLOOR PLAN - FIRE PROTECTION c 0007 - ELECTRICAL E0.1 SYMBOL LEGEND, ABBREVIATIONS, SHEET LIST E0.2 FIXTURE SCHEDULE, NREC FORMS ED1.1 FIRST FLOOR POWER AND SIGNAL DEMO PLAN ED1.2 FIRST FLOOR LIGHTING DEMO PLAN ED1.3 SECOND FLOOR POWER DEMO PLAN ED1.4 SECOND FLOOR LIGHTING DEMO PLAN E2.1 FIRST FLOOR POWER AND SIGNAL PLAN E2.2 SECOND FLOOR POWER AND SIGNAL PLAN E3.1 FIRST FLOOR LIGHTING PLAN E3.2 SECOND FLOOR LIGHTING PLAN E5.1 PARTIAL RISER DIAGRAM E6.1 PANEL SCHEDULES E6.2 PANEL SCHEDULES (2) E6.3 PANEL SCHEDULES (3) By: Date: City of Tukwila BUILDING DIVISION PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com CRSTIMOCIIMAtal 6431 rte; EGORY J. NESPOR STATE OF WASHINGTON REGISTERED ARC HITEC T KING COUNTY ISSUE / REVISIONS ID DATE DESCRIPTION CITY OF TUKWILA JUL 2 8 2017 PERMIT CENTER Project No.: gt@No17ZA Drawn By: WJA Checked By: WJA Sheet Title COVER SHEET G-001 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.Nt 7/27/2017 1:29:40 PM Sheet Size: 22°x34" (24"x36") EMERGENCY ILLUMINATION FOR BUILDINGS AND DURATION OF ILLUMINATION (1008.3.2--1008.3.5) In the event of power supply failure in Rooms and spaces, an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms, 2. Fire command centers, 3. Fire pump rooms, 4. Generator rooms, 5. Public restrooms with an area greater than 300 square feet. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. Illumination level under emergency power, the lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 footcandle and a minimum at any point of 0.1 footcandle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle average and a minimum at any point of 0.06 footcandle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied; illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. Vestibules at level of discharge, 5. Exterior landings and areas used for exit discharge. EXIT TO EXTERIOR CODE LEGEND GROSS OCCUPANT LOAD FOR BUSINESS IS: 68 (6,841 SF/100 SF) EXCLUDING COMPUTER ASSESSMENT LAB 108, CONFERENCE/TRAINING ROOM 130 & CONFERENCE ROOM 118 r OCCUPANT LOAD COLLECTIVE OCCUPANT LOAD AT EXIT • ----- -- - - - - -� EGRESS PATH OF TRAVEL/DIRECTION MAXIMUM TRAVEL PATH FOR B OCCUPANCY WITH SPRINKLERS IS 300' NEW EXIT SIGN EXISTING EXIT SIGN FIRE EXTINGUISHER LOCATION B OCCUPANCY GROSS AREA NOT IN CONTRACT AREA EGRESS CAPACITY = 70" / .15 = 466 ELECT/JANITOR EXIT TO EXTERIOR LOBBY MENS\' RESTROOM EXIT STAIRS EGRESS CAPACITY = 34" / .15 = 226 EGRESS CAPACITY = 34" / .15 = 226 WOMENS RESTROOM CONFERENCE OCCUPANT LOAD = 253 SF/ 15 SF= 16. COMPUTER SSESMENT LAB OCCUPANT LOAD = 729 SF/20 SF= 36 77' FROM EXIT A 52' FROM EXIT. FIRST FLOOR CODE PLAN EGRESSS CAPACITY = 34" / .15 = 226 EGRESSS CAPACITY = 70" / .15 = 466 EXIT STAIRS G-00 SCALE : 1/8" = 1'-0" CODE INFORMATION APPLICABLE CODES BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) PLUS STATE OF WASHINGTON AND CITY OF TUKWILA AMENDMENTS ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE ZONING INFORMATION ZONING: EXISTING USE: LOT SIZE: TUC -P - TUKWILA URBAN CENTER - POND OFFICE BUILDING (B) 300,218 SF BUILDING CODE INFORMATION OCCUPANCY USE: B (NO CHANGE OF OCCUPANCY PROPOSED) NO CHANGE PROPOSED TO BUILDING COMMON AREAS, STRUCTURE, STAIRS OR EXTERIOR. SCOPE LIMITED TO INTERIOR T.I. OF EXISTING SUITE GROSS BUILDING AREA: GROSS AREA SUITE LEVEL 1: GROSS AREA SUITE LEVEL 2: STORIES: SPRINKLER: SPRINKLER SYSTEM: YEAR BUILT: CONSTRUCTION CLASS: 20,610 SF 9,936 SF 10,855 SF 2 YES NFPA 13 - FULLY SPRINKLERED 1978 ASSUMED TO BE TYPE V -B - NON RATED OVERALL BUILDING KEY PLAN A PROJECT SITE X17 SCALE: 1/8" =1'-0" REVIEWED FO CODE COMPLIANCE APPROVED . ASIC a 1 all City of Tukwila BU1L0D OLVI .1 0' 4' 8' 16' 32' EXIT PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 REGISTERED ARC HITEC T E(7ORY J. NESPOR TATE OF WASHINGTON LU Z U w E D W O > (f) Q 6 J O i—i ,, a ao Q o = Z a. Uw Ln QDH ISSUE / REVISIONS ID DATE DESCRIPTION RECE VED ITY OFT KWILA JUL 2 : 2017 Pro e' t'IT CENTER tio17ZA Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR CODE PLAN G 002 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 CentraLssmith@wja-dc.com.rvt 7/27/2017 1:29:41 PM Sheet Size: 22"x34" (24"x36") CODE LEGEND OCCUPANT LOAD COLLECTIVE OCCUPANT LOAD AT EXIT GROSS OCCUPANT LOAD FOR BUSINESS IS: 70 (7,095 SF/100 SF) EXCLUDING CLASSROOMS A, B, C1,C2 & CONFERENCE ROOM 215 < .-------4E- --- -< i EGRESS PATH OF TRAVEUDIRECTION MAXIMUM TRAVEL PATH FOR B OCCUPANCY WITH SPRINKLERS IS 300' NEW EXIT SIGN EXISTING EXIT SIGN FIRE EXTINGUISHER LOCATION B OCCUPANCY GROSS AREA NOT IN CONTRACT AREA EGRESS CAPACITY = 34" / .15 = 226 1 <- 52' FROM EXIT CLASSROOM C2� .' OCCUPANT LOAD = 897 SF/20 SF=44 OCCUPANT LOAD = 421 SF/20SF=21 CONF ROOM 51' FROM EXIT -+ - ---k< 54' FROM EXIT EXIT STAIRS SECOND FLOOR CODE PLAN G-003 SCALE : 1/8" =1-0" CODE INFORMATION APPLICABLE CODES BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) PLUS STATE OF WASHINGTON AND CITY OF TUKWILA AMENDMENTS ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE ZONING INFORMATION ZONING: TUC -P - TUKWILA URBAN CENTER - POND EXISTING USE: OFFICE BUILDING (B) LOT SIZE: 300,218 SF BUILDING CODE INFORMATION OCCUPANCY USE: B (NO CHANGE OF OCCUPANCY PROPOSED) NO CHANGE PROPOSED TO BUILDING COMMON AREAS, STRUCTURE, STAIRS OR EXTERIOR. SCOPE LIMITED TO INTERIOR T.I. OF EXISTING SUITE GROSS BUILDING AREA: GROSS AREA SUITE LEVEL 1: GROSS AREA SUITE LEVEL 2: STORIES: SPRINKLER: SPRINKLER SYSTEM: YEAR BUILT: CONSTRUCTION CLASS: 20,610 SF 9,936 SF 10,855 SF 2 YES NFPA 13 - FULLY SPRINKLERED 1978 ASSUMED TO BE TYPE V -B - NON RATED OVERALL BUILDING KEY PLAN A • A PROJECT SITE REVIEWED FO CODE COMPLIANCE APPROVED br7%..o2t SCALE: 1/8" =1'-0" AUG 31 O11 City of Tukwila BUILDING DIVISION 0' 4' 8' 16' 32' EXIT PERMIT SET - JULY 21, 2017 REGISTERED ARC HITEC T r/ IA 'E(�ORY J. NESPOR STATE OF WASHINGTON King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 Cn W Z U w oC 5 D 0> V) O 6 fy o c m 0 ce� z U) Q O g _ Z ""' W Ln Y ISSUE / REVISIONS ID DESCRIPTION Checked By: Checker Sheet Title SECOND FLOOR CODE PLAN G-003 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 7/27/2017 1:29:23 PM Sheet Size: 22"x34" (24"x36") GENERAL ABBREVIATIONS ACT AFF ALUM ARCH AA/. BD BLDG BOT BRK CBB CFCI CG CIRC CLG CLR CNTR COL COMM CONT COORD CR DBL DET DF DIA DIM DK DR DWG(S) EA ELEV ELEC EQ EQUIP EW EXIST EXP EXT FA FEC, FE FEB FF FIN FLR FP FRTW FT FOC FOM FOS FURR GA GFGI GL GT GYPBD, GWB GYP HM HORIZ HT HW, HDWR INSUL INT MAT MAX MECH MEP MET, MTL MFR MG MIN MR MTD NIC NO NTS OC OD OFCI OFOI OPH OPP ACOUSTICAL CEILING TILE ABOVE FINISHED FLOOR ALUMINUM ARCHITECT (URAL) AUDIO VISUAL BOARD BUILDING BOTTOM BREAK CEMENTITIOUS BACKER BOARD CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CORNER GUARD CIRCULATION CEILING CLEAR (ANCE) CENTER COLUMN COMMUNICATIONS CONTINUOUS OR CONTINUE COORDINATE CHAIR RAIL DOUBLE DETAIL DRINKING FOUNTAIN DIAMETE R DIMENSION DECK DOOR DRAWING(S) EACH ELEVATION/ELEVATOR ELECTRIC(AL) EQUAL EQUIPMENT EACH WAY EXISTING EXPOSED, EXPANDED, EXPANSION EXTERIOR, EXTENSION FIRE ALARM FIRE EXTINGUISHER (CABINET) FIRE EXTINGUISHER BRACKET FINISHED FLOOR OR FACTORY FINISH FINISH (ED) FLOOR (ING) FIRE PROTECTION FIRE RETARDANT TREATED WOOD FLOOR TRIM RCP REF REQ'D REV RM RO RR SCWD SF SIM SPEC SQ SS ST, STL STC STN STOR STRUCT SUSP TO TBD TRT TYP UNF UNO REFLECTED CEILING PLAN REFERENCE REQUIRED REVISION (S), REVISED ROOM ROUGH OPENING RESTROOM SOLID CORE WOOD (DOOR) SQUARE FOOTAGE SIMILAR SPECIFICATION SQUARE STAINLESS STEEL OR SOLID SURFACE STEEL SOUND TRANSMISSION CLASS STAIN STORAGE STRUCTURAL SUSPENDED TOP OF TO BE DETERMINED TREATED TYPICAL UNFINISHED UNLESS NOTED OTHERWISE VERT VERTICAL VR VAPOR RETARDER W/ W WD WP WR WITH WIDE, WAY, WEST WOOD WALL PANEL WATER RESISTANT SYMBOLS L ANGLE & AND AT 0 DIAMETER DEGREE CENTER LINE FACE OF CONCRETE FACE OF MASONRY FACE OF STUD/STEEL FURRING GAGE, GAUGE GOVERNMENT FURNISHED, GOVERMENT INSTALLED GRID LINE GROUT GYPSUM WALL BOARD GYPSUM HOLLOW METAL HORIZONTAL HEIGHT HARDWARE INSULATION INTERIOR(S) MATERIAL MAXIMUM MECHANIC (AL) MECHANICAL, ELECTRICAL, PLUMBING METAL MANUFACTURER MIRROR, GLASS MINIMUM MOISTURE RESISTANT MOUNTED NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER (S) OUTSIDE DIAMETER OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FURNISHED, OWNER INSTALLED OPPOSITE HAND OPPOSITE FINISHES AND EQUIPMENT ABBREVIATIONS LAV - RA -BCS RA -CH RA -GB RA -M RA -PTD RA -SCD RA -SD RA -TPD TLT HATCH SYMBOLS LAVATORY/SINK BABY CHANGING STATION COAT HOOK GRAB BAR MIRROR PAPER TOWEL DISPENSER SEAT COVER DISPENSER (TOILET) SOAP DISPENSER TOILET PAPER DISPENSER TOILET GYPSUM NOT IN CONTRACT, NIC EXISTING WALLS — EXISTING WALL TO BE DEMOLISHED PLAN SYMBOLS WOOD WOOD STUDS, BLOCKING BATT INSULATION ACOUSTICAL TILE CALL -OUTS IDENTIFICATION SA -2 P3 (101) Room name 101 CPT DETAIL SYMBOL NUMBER INDICATES DETAIL SHEET NUMBER WHERE DETAIL IS DRAWN INTERIOR ELEVATION SYMBOL NUMBER INDICATES INTERIOR ELEVATION COMPASS POINTS INDICATES WHICH ELEVATIONS ARE DRAWN SHEET NUMBER WHERE ELEVATION IS DRAWN VERTICAL OR SPOT ELEVATION NORTH ARROW ROOF, SOFFIT, FLOOR, CEILING TYPE FEC CONSTRUCTION GRID LINE WALL TYPE, SEE A-601 FOR WALL SCHEDULE KEYNOTE DOOR, SEE A-601 FOR DOOR SCHEDULE ROOM NAME ROOM NUMBER DURING CONSTRUCTION VCT FLOOR FINISH TRANSITION CG II FIRE EXTINGUISHER CABINET - SEMI - RECESSED CORNER GUARD LOCATION GENERAL NOTES 1. REPETITIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 2. DIMENSIONS ON DRAWINGS ARE TAKEN TO/FROM THE LOCATIONS LISTED BELOW UNLESS OTHERWISE INDICATED: CENTERLINES OF STUDS FOR METAL STUD WALLS CENTERLINES OF DOORS IN METAL STUD WALLS FINISH FACE FOR EXISTING WALLS GRID LINES 4. DIMENSIONS ON INTERIOR ELEVATIONS ARE TAKEN TO/FROM THE: FINISHED GYPSUM WALLBOARD CABINETRY CENTERLINES OF FIXTURES 5. PLAN VIEWS ARE CUT AT 4'-0" AFF 6. GRID LINES ARE FOR REFERENCE AND COORDINATION PURPOSE ONLY 7. MECHANICAL AND ELECTRICAL INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS ARE PROVIDED FOR CLARITY AND/OR LOCATIONAL PURPOSES ONLY. SEE MECHANICAL AND ELECTRICAL DRAWINGS. 8. ALL WORK SHALL COMPLY WITH 2015 INTERNATIONAL BUILDING CODE (IBC) AS ADOPTED BY THE STATE OF WASHINGTON 9. ALL NEW DOORS IN STUD WALLS NOT LOCATED BY DIMENSION ON PLANS OR DETAILS SHALL BE 4" FROM FACE OF ADJACENT PERPENDICULAR WALL TO EDGE OF DOOR OPENING. 10 ROOM AND DOOR NUMBERS SHOWN ON DRAWINGS ARE FOR CONSTRUCTION PURPOSES ONLY. GENERAL DEMOLITION NOTES 1. IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. 2. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS, AND THEY MAY NOT REFLECT ACTUAL FIELD CONDITIONS. PRIOR TO PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO EXISTING FIELD CONDITIONS AND THEN IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS. 3. THE CONTRACTOR SHALL IMEDIATELY NOTIFY THE ARCHITECT IN WRITING IF ANY DEMOLITION OR NEW CONSTRUCTION WORK (AS INDICATED IN THE CONSTRUCTION DOCUMENTS) CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS 4. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING -TO -REMAIN MATERIALS AND FINISHES (CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, WINDOWS, FRAMES, WALL PROTECTION, ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION. 5. THE CONTRACTOR SHALL NOT CUT EXISTING STRUCTURAL WORK IN ANY MANNER THAT MAY RESULT IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN WRITING IN ADVANCE FROM THE ARCHITECT AND STRUCTURAL ENGINEER. 6. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ARCHITECT IN WRITING. NOTE: REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS MATERIAL IS THE SOLE RESPONSIBILITY OF THE OWNER, AND SHALL BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 Z011 City of Tukwila BUILDING. DIVISION N/ (no/ PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division apital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative. 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 6 'E(JORY J. NESPOR STATE OF WASHINGTON REGISTERED ARC HITEC T KING COUNTY (1) LU Z U w Ce 2 n W O> tip Q 6 cl. rn co O H °,2, co 0- cn rn > a'S U) Q o _ Q" U w Ln Y I— � N ISSUE / REVISIONS D DATE DESCRIPTION CITY fCEIVED J1t282017 PER ER Project No.: §47o17ZA Drawn By: Author Checked By: Checker Sheet Title ARCHITECTURAL GENERAL NOTES AND LEGENDS A-001 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:24 PM Sheet Size: 22"x34" (24"x36") 2'-0" 1'-9" / 11" MIN 8" MIN / / Z Z 0 ih 0 CONTROL WALL ACCESSIBLE SINK CONTROL PLAN 0 SCALE : 1/2" = 5'-0" DIA. MIN 2 0 in 1'-0"MIS ACCESSIBILITY GENERAL NOTES 1. ALL MOUNTING HEIGHTS & ACCESSIBILITY DETAILS SHOWN HERE APPLY THROUGHOUT UNO. f z 0 M L_ 3'-0"MIN �1'-0"MIN L 60" DIA. CLEAR AREA AS SHOWN ON PLAN 'T' SHAPED CLEAR AREA AS SHOWN ON PLAN ACCESSIBLE MANEUVERING CLEARANCE AND APPROACH SINK DISHWASHER REFRIGERATOR STOVETOP 145" X 30" LDERPENDICULa.AR APPROACH 1 130" X 48" PARALLEL SCALE : 1/2" =11-0" 39" MIN 1'-0"MAX 2 co co 0 C) 41" MAX O) co d' 3'-6"MIN c 1'-6" TOILET PAPER DISPENSER & SANITARY NAPKIN DISPOSAL (Y) Q CO \� RECESSED TOILET SEAT COVER DISPENSERS (TSCD) WATER CLOSETS (REGULAR AND ADA) 2 � O 3'-0"MIN' DOOR mor 0 LIGHT SWITCH OUTLET COAT HOOKS SOAP DISPENSER MIRROR ACCESSIBLE MOUNTING HEIGHTS BABY CHANGING STATION REVIEWED FOR CODE COMPLIANCE APPROVED AUS 31 zr11 City of Tukwila BUILDING DIVISION SCALE : 1/2" = bLiOz 1 PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative; 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 KING COUNTY REGISTERED ARC HITEC T EGORY 3. NESPOR STATE OF WASHINGTON (n W ~ U z �w O> ct O1-1 Z (� Q = Z U W DIf— ISSUE / REVISIONS ID DATE DESCRIPTION CITY 0 Project No.: io17ZA Drawn By: Author Checked By: Checker Sheet Title ACCESSIBILITY DETAILS A-002 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 8/23/2017 11:19:13 AM feet Size: 22"x34" (24"x36") EXISTING ACCESSIBLE DRINKING FOUNTAIN TO REMAIN 1 FIRST FLOOR DEMOLITION PLAN - WEST D10 SCALE : 1/4" = 1'-0" —M1 1 ' . , , . 7 I 4" SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND \\ NOT IN CONTRACT — — — EXISTING TO BE DEMOLISHED EXISTING TO REMAIN KEYNOTE LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 City Or Tukwila BUILMO.D.LVISION KEY VALUE KEYNOTE TEXT 1 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. D �1 e 101 ry SCALE: 1/4" = 1'-0" WEST EAST 16' N PERMIT CORRECTIONS -AUGUST 23, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com KING COUNTY 03 °,21 I - ISSUE / REVISIONS ID DATE DESCRIPTION 2017-08-23 PERMIT CORRECTIONS Project No.: 15032-17ZA Site No.: Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR DEMOLITION PLAN WEST AD101 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 CentraLssmith@wja-dc.com.rvt 7/27/2017 1:29:36 PM Sheet Size: 22"x34" (24"x36") v====' / 1=1— I I 1I (1) II II I I I I I I I I II I I I I 1 41 r = / SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT — — — EXISTING TO BE DEMOLISHED EXISTING TO REMAIN KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT REVIEWED FOR CODE COMPLIANCE APPROVED • AUG 31 2011 Tukwila BI IU DINCityof TuG DIVSION_ 1 1'7 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. off MATCHLINE 0 Q 1 11 FIRST FLOOR DEMOLITION PLAN - EAST D10 SCALE : 1/4" = 1,-0" 01011 SCALE: 1/4" =1'-0" WEST EAST 0' 2' 16' PERMIT SET -JULY 21, 2017 0,4,3262,047.1111 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com f'EGORY J. NESPOR STATE OF WASHINGTON *411, 31 REGISTERED ARCHITECT KING COUNTY ..11061021,10001.1, kr) 0 J cc C <00 CL rn wit 0 zg kr)l ISSUE / REVISIONS ID DATE DESCRIPTION CITYcj REM JUL 2 8 2017 PERMIT CENTER Project No.: etAo17ZA Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR DEMOLITION PLAN EAST AD102 E 8 U C6 a) C.) ti 0 (NI a) cri O 0 c 0 0 a) 8/23/2017 11:19:13 AM eet Size: 22"x34" (24"x36") EXISTING ACCESSIBLE DRINKING FOUNTAIN TO REMAIN EXISTING COLUMN MUST REMAIN 1 18'-6" (110 I Iw SECOND FLOOR DEMOLITION PLAN - WEST ND10y SCALE : 1/4" =11-0" I SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT EXISTING TO BE DEMOLISHED EXISTING TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 KEYNOTE LEGEND BUILT i 1 11\11 011 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. KEY VALUE KEYNOTE TEXT 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. 1 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. 11 e WEST EAST SCALE: 1/4" =1'-0" 16' PERMIT CORRECTIONS - AUGUST 23, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com KING COUNTY (n F- LU U z �w O> (inO oC a O1-4 Z (n Q = Z U W D I— ISSUE / REVISIONS ID DATE DESCRIPTION 1 2017-08-23 PERMIT CORRECTIONS Project No.: 15032-17ZA Site No.: Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR DEMOLITION PLAN - WEST AD103 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 7/27/2017 1:29:37 PM Sheet Size: 22"x34" (24"x36") i I 1r I I I --1 I 1 III =JJ rr L Ti 1 II L I SECOND FLOOR DEMOLITION PLAN - EAST D104/ SCALE : 1/4" = 1'-0" SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT — EXISTING TO BE DEMOLISHED EXISTING TO REMAIN KEYNOTE LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 Ci BUILDING DIVISION KEY VALUE KEYNOTE TEXT 1 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. pig 0201 SCALE: 1/4" = 1'-0" WEST EAST 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EGORY J. NESPOR STATE OF WASHINGTON ISSUE / REVISIONS ID DATE DESCRIPTION Project No.: to17ZA Checked By: Checker Sheet Title SECOND FLOOR DEMOLITION PLAN - EAST C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.nit 7/27/2017 1:29:38 PM Sheet Size: 22"x34" (24"x36") \ \ . . . . -):\ -1:-. .. .. IV . N k. N , %N, , N\N' i k"... LI m I kl wilk ALE" Wh.M."M`tIlan 4 ii, 1 \ kxak,--c. .,\ kl, ‘,.. X. .X.: N.. ...._ .......-......-- 1,,---_, NI! N\ i I 1 N 6..,.... ...---..-4.----.--A FIRST FLOOR DEMOLITION RCP - WEST 1AD11 SCALE : 1/4" = 1'-0" 1 1 1 1 1 A SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT — — - EXISTING TO BE DEMOLISHED EXISTING TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED AUG 3 1 2017 KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT City of Tukwila RUILDING DIVISION 1 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. ago WEST EAST SCALE: 1/4" =1-0" 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 5431 REGISTERED ARCHITEC T KING COUNTY EcORY J. NESPOR STATE OF WASHINGTON utratassarvmasaassortrett 0 J m Y co aco rn W< O 'S zg ko ISSUE / REVISIONS ID DATE DESCRIPTION CITY REC LVED UKWILA 2 PERMITJUL ENTER 1TER Project No.: Io17ZA Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR DEMOLITION RCP - WEST AD111 C:IUsers\Shane Smith\Documents\DCHS Renton Worksource - 2017 CentraLssmith@wja-dc.com.rvt 7/27/2017 1:29:38 PM Sheet Size: 22"x34" (24"x36") SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND \\\ NOT IN CONTRACT - - - EXISTING TO BE DEMOLISHED EXISTING TO REMAIN KEYNOTE LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 City of Tukwila: BUILDING DIVISION KEY VALUE KEYNOTE TEXT 1 DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. 1 1 1 FIRST FLOOR DEMOLITION RCP - EAST l D19/ SCALE : 1/4" = 1'-0" 11: 020f SCALE: 1/4" =1'-0" WEST EAST 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 2213 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 'EGORY J. NESPOR STATE OF WASHINGTON KING COUNTY ISSUE / REVISIONS ID DATE DESCRIPTION RECEIVED JUL. 28 2017 IVTER Project No.: 1107017A Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR DEMOLITION RCP - EAST C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 7/27/2017 1:29:39 PM Sheet Size: 22"x34" (24"x36") I L I - 0 !a B SECOND FLOOR DEMOLITION RCP - WEST D11 SCALE : 1/4" = 1'-0" SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. • NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT _ - - EXISTING TO BE DEMOLISHED EXISTING TO REMAIN KEYNOTE LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2Q11 City of Tukwila BUILDiNQ IPL KEY VALUE KEYNOTE TEXT 1 n DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. 0.101 1 SCALE: 1/4" =1'-0" WEST EAST 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com K 6431 REGISTERED ARC HITEC T E ORY J. NESPOR STATE OF WASHINGTON ISSUE I REVISIONS ID DATE DESCRIPTION RECEIVED UKW JUL 2 8 2011 PERMIT CENTER Project No.: io17ZA Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR DEMOLITION RCP - WEST AD113 E 8 co cn ii' O 0 A 0 0 a) 0 0 7/27/2017 1:29:39 PM Sheet Size: 22"x34" (24"x36") e 1111 1 • =- ENIMEir‘l. I Mil r MIME i 11111 111 ma, 7\ __ ice______ J= 0 e e II 1 1K i< fC I IA I IN NMI EINEM SECOND FLOOR DEMOLITION RCP - EAST SHEET DEMOLITION NOTES 1. REFERENCE SHEET A-001 FOR GENERAL DEMOLITION NOTES. 2. CONTRACTOR MUST VERIFY EXISTING CONDITIONS. 3. REMOVE FROM SITE AS SOON AS PRACTICABLE: DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 4. PROTECT FROM DAMAGE ALL BUILDING COMPONENTS IDENTIFIED TO REMAIN IN PLACE 5. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 6. DEMOLISH ALL EXISTING FLOOR COVERINGS DOWN TO SUB -FLOOR, REPLACE WITH NEW FLOORING AS NOTED ON SHEET 1-101 -1-104 7. REMOVE EXISTING RUBBER BASE IN ALL AREAS AND REPLACE. NOTE: IT IS THE EXPLICIT RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING WALLS. NO DEMOLITION IS TO BE STARTED UNTIL THIS VERIFICATION IS MADE. IF ANY WALLS TO BE REMOVED ARE SUSPECTED OF BEING LOAD BEARING, KING COUNTY PROJECT REPRESENTATIVES SHALL BE NOTIFIED, SUCH THAT A STRUCTURAL ENGINEER CAN VERIFY THE CONDITION, AND PROVIDE AN ALTERNATIVE APPROACH. DEMOLITION LEGEND NOT IN CONTRACT - - - EXISTING TO BE DEMOLISHED EXISTING TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT City of Tukwila P BUILDING DIVISION, -- 1 =I= DEMOLISH EXISTING WALL BACK TO LOCATION SHOWN. 2 SALVAGE AND SET ASIDE IDENTIFIED EXISTING DOORS AND FRAMES TO PROTECT FROM DAMAGE. DOORS ARE TO BE REINSTALLED DURING THE CONSTRUCTION PHASE. 3 SALVAGE AND SET ASIDE IDENTIFIED CASEWORK TO PROTECT FROM DAMAGE. CASEWORK IS TO BE REINSTALLED AS NOTED DURING THE CONSTRUCTION PHASE. 4 DEMOLISH EXISTING WALL FOR DOOR OPENING, SEE RELEVANT NEW CONSTRUCTION PLANS AND DOOR SCHEDULE FOR OPENING HIEGHT. 5 DEMOLISH EXISTING LIGHT FIXTURES WHERE NOTED, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 RELOCATE IDENTIFIED EXISTING LIGHT FIXTURE TO NEAREST LOCATION SHOWN ON NEW REFLECTED CEILING PLANS. bri O 'D11- SCALE : 1/4" = l'-0" SCALE: 1/4" =1'-0" WEST EAST 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 4Olt 011P KING COUNTY REGISTERED ARC HITEC T EGORY J. NESPOR STATE OF WASHINGTON ISSUE/REVISIONS ID DATE DESCRIPTION CITYE 4) F KWILA JUL 28 2017 PERMIT CENTER Project No.: I'i'to17ZA Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR DEMOLITION RCP - EAST AD114 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 8/23/2017 11:19:12 AM eet Size: 22"x34" (24"x36") O 0 L r, ELECT/JANITO STORAGE EXISTING STAIR TELECOM 131 ENS\ TROOM EXISTING ACCESSIBLE DRINKING FOUNTAIN TO REMAIN (105) WOMENS RESTROOM ENTRY CORRIDOR 105 ADA GENDER NEUTRAL RESTROOM 132 (132) 16'-2" J CG t S1 (106)— (109) 6' I- 0" 130A) 0\ CONFERENCE/ TRAINING 130 S1 CG S1 CG 2'-0" /TYP CORRIDOR CG CG CG 9' - 11 WAITING AREA 106 EQ EQ (A-401) 5 0 M 0 -J CG CG COUNTER @34"AFF COUNTER @ 42" AFF COUNTER @ 34" AFF, CABINETS BELOW CG RECEPTION CG M COMPUTER ASSESMENT LAB 109 J CG CG (1308) MEETING ROOM 116 CG CG S1 CG 3'-0" (116 ) STORAGE 115 9' - 4 5/8" 108 ALIGN ALIGN ( 110 ) 0 0 0 a r ADMIN AREA MEETING ROOM 110 RESOURCES JJ O— STORAGE 108A FIRST FLOOR PLAN - WEST SCALE : 1/4" = 1'-0" MEETING ROOM 111 L L 111A) _J STORAGE 111A z J N 2 O 0 - Q FLOOR PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES 2. REFERENCE SHEET A-601 FOR WALL TYPES, DOOR TYPES AND DOOR SCHEDULE 3. PLAN VIEWS ARE CUT AT 4'-0" AFF 4. FURNITURE SHOWN FOR REFERENCE ONLY 5. VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ARCHITECT AND CONTRACTING OFFICER OF DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS FLOOR PLAN LEGEND \\ NOT IN CONTRACT NEW PARTITION WALL EXISTING WALL TO REMAIN 7'-6" 7r 7r —�r -r- S2 S1 o ti S1 J 0 L!) ar w J 0 S1 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2.017 City of Tut rila BUILDINt__, 1MIQN P � ENLARGED ADA GENDER NEUTRAL RESTROOM SCALE : 1/2" = 1'-0" C O R R€'`TN LTR# WEST EAST SCALE: 1/4" =1-0" RECEIVED CITY OF TUKWILA AUG 2 ' 2017 PERMIT CENTER N King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative: 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com ISSUE / REVISIONS DATE DESCRIPTION 2017-08-23 PERMIT CORRECTIONS Project No.: 15032-17ZA Site No.: Drawn By: WJA Checked By: WJA Sheet Title FIRST FLOOR PLAN - WEST 0' 16' RMIT CORRECTIONS -AUGUST 23, 2017 \ \ \ \ \ \ \ \ \\\N C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:26 PM 0 KITCHEN/-, COFFEE BREAK ROOM 126 0 3 0 ii (1306) CG (126) SECURE FILE STORAGE (129) 129 MEETING ROOM 117 WELLNESS (128) 128 MEETING ROOM 127 CORRIDOR 109 lj—(118A) (1186) CG COPY/MAIL/ STORAGE 125 CG WORK AREA 124 (127) CG CONFERENCE 118 MEETING ROOM 112 9'-9" 1.. (114) S1 S1 S1 MEETING ROOM 113 SIM MEETING ROOM 114 FIRST FLOOR PLAN - EAST CG CG CG (123) MEETING ROOM 123 CG CG CG OPEN OFFICE 122 CG STORAGE CG CG (120) STORAGE/ RESOURCES 120 OPEN OFFICE 121 CG . CG (121A) FLOOR PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES 2. REFERENCE SHEET A-601 FOR WALL TYPES, DOOR TYPES AND DOOR SCHEDULE 3. PLAN VIEWS ARE CUT AT 4'-0" AFF 4. FURNITURE SHOWN FOR REFERENCE ONLY 5. VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ARCHITECT AND CONTRACTING OFFICER OF DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS FLOOR PLAN LEGEND NOT IN CONTRACT NEW PARTITION WALL EXISTING WALL TO REMAIN tyr7 020 1 -102 SCALE : 1/4" = 1'-0" WEST EAST SCALE: 1/4" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 City of Tukwila BUILDINQ.DIVISION 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative. 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 REGISTERED ARC HITEC T EGORY J. NESPOR STATE OF WASHINGTON KING COUNTY LLI Z U W CC z D W 0 > ko cri O 6 ce o ca_ ctD O " ce CI- 01 V lO _ � zg U Z LL! Lr)Y l0 F - ISSUE I REVISIONS ID DATE DESCRIPTION CIT' ER OruKwit l�Ep UL 282017 IT CENTER Project No.: t'io17ZA Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR PLAN - EAST A-102 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 8/23/2017 11:19:13 AM feet Size: 22"x34" (24"x36") i i I EXISTING STAIR CLASSROOM A. LOBBY EXISTING ACCESSIBLE DRINKING FOUNTAIN TO REMAIN 209 ) KCIT CLOSET WOMENS RESTROOM ALIGN WELLNESS/' LACTATION ROOM SALVAGED SINK & CASEWORK (227) CG ALIGN CORRIDOR 209 z J CG 219) A-501 RESOURCE AND COMPUTERS 201 S1 MEETING ROOM 202 a S1 202 2'-2" MEETING ROOM 204 204 203 ) 1 RECEPTION/ WAITING AREA 203 3'-5" 34" AFF, CABINETS BELOW 0 42" AFF (210) 7'-8" CLASSROOM B (203B) 206 ) MEETING ROOM 206 13'-61/2' p SECOND FLOOR PLAN - WEST -103 SCALE : 1/4" = 1'-0" 26'-31/2" MEETING ROOM 207 moi hmonsimmommi 115128111 I'll e FLOOR PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES 2. REFERENCE SHEET A-601 FOR WALL TYPES, DOOR TYPES AND DOOR SCHEDULE 3. PLAN VIEWS ARE CUT AT 4'-0" AFF 4. FURNITURE SHOWN FOR REFERENCE ONLY 5. VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ARCHITECT AND CONTRACTING OFFICER OF DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS FLOOR PLAN LEGEND NOT IN CONTRACT NEW PARTITION WALL EXISTING WALL TO REMAIN (7:: 0 .01 WEST EAST SCALE: 1/4" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 City of Tukwila BUILDING DIVISION 0' 16' PERMIT CORRECTIONS - AUGUST 23, 2017 L43 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com KING COUNTY .. 1— W Z U Lu D W 0 (In Q 6 oC o ca. co 0 1--1 cc 008 a00 al Z (I) Qo _ z. U W LnY tOH ISSUE / REVISIONS ID DATE DESCRIPTION 2017-08-23 PERMIT CORRECTIONS Project No.: 15032-17ZA Site No.: Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR PLAN - WEST VICISIONSVKINIVIESIVILIVA A 103 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt Q- 00 N C) N r -- (NI N ti Sheet Size: 22"x34" (24"x36") I I I IL S1 CN CV c+o I_=I (219) (210) MEETING ROOM., 224 S1 ( 224 ) MEETING ROOM 223 n (223 ) CG S1 S1 CLASSROOM Cl 210 CLASSROOM C2 211 S1 (21 OA) RTC INSTRUCTOR OFFICE 210A OPEN OFFICE 219 CG CG ALIGN S1 (211) S1 (212) TESTING AREA 212 MATCHLINE 1 214 BREAK ROOM 214 MEETING ROOM 222 MEETING ROOM 221 1 SECURED FILE STORAGE 217 ( 217 (220) fl MEETING`' ROOM 220 11 x(218) MEETING ROOM 218 CG CG COORIDOOR 213 CG T (213) SECOND FLOOR PLAN CONCEPT SCALE : 1/4" = 1'-0" ( 21 6 ) 215B CONF ROOM 215 (215A) SECURE OPEN OFFICE 216 FLOOR PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES 2. REFERENCE SHEET A-601 FOR WALL TYPES, DOOR TYPES AND DOOR SCHEDULE 3. PLAN VIEWS ARE CUT AT 4'-0" AFF 4. FURNITURE SHOWN FOR REFERENCE ONLY 5. VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD. NOTIFY ARCHITECT AND CONTRACTING OFFICER OF DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS FLOOR PLAN LEGEND \\ NOT IN CONTRACT NEW PARTITION WALL EXISTING WALL TO REMAIN WEST EAST SCALE: 1/4" = 1'-0" 0' 8' REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2017 City of Tukwila BUILDING D1VISM N PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 ioil, A,'EGORy J. NESPOR STATE OF WASHINGTON REGISTERED ARC HITEC T ■ ■ I— LLI z Uw oC \ D W O > CI) p c o d. m D O i cz Z '' U w a� O F—ko 11-- ISSUE / REVISIONS ID DATE DESCRIPTION erne LVED V 81017 I ER Project No.: t!o17ZA Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR PLAN - EAST A-104 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt Sheet Size: 22"x34" (24"x36") ELECT/JANITOR LOBB MENS RESTROOM TELECOM 131 WOMENS� RESTROOM ENTRY CORRIDOR MEETING ROOM WAITING AREA COMPUTER ASSESMENT LAB ADMIN AREA _f107B MEETING ROOM MEETING ROOM 0 RESOURCES STORAGE STORAGE FIRST FLOOR REFLECTED CEILING PLAN - WEST SCALE : 1/4" = 1'-0" 1 1 l� 0 CEILING PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES. 2. REFERENCE SHEET A-601 FOR WALL AND CEILING ASSEMBLIES 3. ACOUSTICAL CEILING TILE GRIDS ARE TO BE CENTERED IN ROOMS UNLESS OTHERWISE NOTED. 4. LIGHT FIXTURES ARE TO BE CENTERED IN ACOUSTICAL CEILING TILE GRIDS AS INDICATED OR CENTERED IN ROOMS, UNLESS DIMENSIONED OTHERWISE. 5. DIMENSIONS FOR LIGHTS ARE TO FACE OF GYPSUM WALLBOARD AND TO CENTERLINE OF FIXTURE. 7. REFERENCE SHEET A-502 FOR TYPICAL ACT DETAILS. 410 RCP LEGEND O WEST WALL MOUNTED FIXTURE RECESSED LIGHT FIXTURE 2X4 ACT GWB CEILING RECESSED FIXTURE PER ELECTRICAL PENDANT FIXTURE PER ELECTRICAL EXISTING EXIT SIGN LOCATION EXIT SIGN LOCATION EXISTING WALL NEW PARTITION WALL ACCESS PANEL SUPPLY DIFFUSER RETURN DIFFUSr REVIEWED FOR SPODE COMPLIANCE APPROVED AN 31211 EAST SCALE: 1/4" = 1'-0" City of Tukwila BUILDING DIVIS 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 ))0111,1140/ 'EGORY J. NESPOR `TATE OF WASHINGTON REGISTERED ARC HITEC T ..I— w Z U w It E D 0> kip (1)p 6 o ce d. m 0 i—i ce Z w Q O _ �� U � z W u,Y L0 I— ISSUE / REVISIONS ID DATE DESCRIPTION Project No.: 'i @$7o17ZA Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR REFLECTED CEILING PLAN WEST 111 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:30 PM Sheet Size: 22"x34" (24"x36") 1 1 IMill CONFERENCE/ TRAINING 1611, 130 SECURE FILE STORAGE 129 STORAGE 1.7‘I KITCHEN/ 125 23 COFFEE BREAK ROOM 126 WELLNESS 128 MEETING ROOM 1 ..1127 pi= CORRIDOR 109 1111111 =OM • 1 ormiPlimmi CONFERENCE Erg MEI O \/ \/ CORRIDOR MEETING ROOM MEETING ROOM MEETING ROOM ESIBUILE i 11 12 0 111 1 TORAGE/ RESOURCES S OPEN OFFICE 121 • 1 I •1 1 STORAGE 1 FIRST FLOOR REFLECTED CEILING PLAN - EAST 1 112 SCALE : 1/4" = 1'-0" b17 O2O O CEILING PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES. 2. REFERENCE SHEET A-601 FOR WALL AND CEILING ASSEMBLIES 3. ACOUSTICAL CEILING TILE GRIDS ARE TO BE CENTERED IN ROOMS UNLESS OTHERWISE NOTED. 4. LIGHT FIXTURES ARE TO BE CENTERED IN ACOUSTICAL CEILING TILE GRIDS AS INDICATED OR CENTERED IN ROOMS, UNLESS DIMENSIONED OTHERWISE. 5. DIMENSIONS FOR LIGHTS ARE TO FACE OF GYPSUM WALLBOARD AND TO CENTERLINE OF FIXTURE. 7. REFERENCE SHEET A-502 FOR TYPICAL ACT DETAILS. RCP LEGEND O 0 WEST WALL MOUNTED FIXTURE RECESSED LIGHT FIXTURE 2X4 ACT GWB CEILING RECESSED FIXTURE PER ELECTRICAL PENDANT FIXTURE PER ELECTRICAL EXISTING EXIT SIGN LOCATION EXIT SIGN LOCATION EXISTING WALL NEW PARTITION WALL ACCESS PANEL SUPPLY DIFFUSER RETURN DIFF EAST SCALE: 1/4" =1'-0" ~` T VIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 City of Tukwila BUILDING sm1S1O 1 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com AMEMMIEWIlint- 6431 REGISTERED ARC HITEC T .-� 'EGORY J. NESPOR STATE OF WASH!iNGTON UJ Z U w D W O > (1)O o Ce cl. m co O i i ce rn Z >< (.1) <o U w Ln Y � I- ISSUE / REVISIONS ID DATE DESCRIPTION C11"y pE Project No.: t!o17ZA R Drawn By: Author Checked By: Checker Sheet Title FIRST FLOOR REFLECTED CEILING PLAN - EAST �-112 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:31 PM Sheet Size: 22"x34" (24"x36") 1 i OPEN OFFICE 0 CORRIDOR RESOURCE AND COMPUTERS 201 RECEPTION/ WAITING AREA CLASSROOM Cl MEETING ROOM CLASSROOM B MEETING ROOM CLASSROOM C2 211 SECOND FLOOR REFLECTED CEILING PLAN - WEST -113 SCALE : 1/4" = 1'-0" bri 0.0 CEILING PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES. 2. REFERENCE SHEET A-601 FOR WALL AND CEILING ASSEMBLIES 3. ACOUSTICAL CEILING TILE GRIDS ARE TO BE CENTERED IN ROOMS UNLESS OTHERWISE NOTED. 4. LIGHT FIXTURES ARE TO BE CENTERED IN ACOUSTICAL CEILING TILE GRIDS AS INDICATED OR CENTERED IN ROOMS, UNLESS DIMENSIONED OTHERWISE. 5. DIMENSIONS FOR LIGHTS ARE TO FACE OF GYPSUM WALLBOARD AND TO CENTERLINE OF FIXTURE. 7. REFERENCE SHEET A-502 FOR TYPICAL ACT DETAILS. RCP LEGEND O WALL MOUNTED FIXTURE RECESSED LIGHT FIXTURE 2X4 ACT GWB CEILING RECESSED FIXTURE PER ELECTRICAL PENDANT FIXTURE PER ELECTRICAL EXISTING EXIT SIGN LOCATION EXIT SIGN LOCATION EXISTING WALL NEW PARTITION WALL ACCESS. PANEL SUPPLY DIFFUSER RETURN DIFFUSER WEST EAST REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2g17 SCALE: 1/4" = 1'-0" City of Tukwila BUILDIN r 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborativ 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 KING COUNTY REGISTERED ARC HITEC T EGORY J. NESPOR STATE OF WASHINGTON (n F— LU ~ z U � w Oj YO ce fa. z cn Q z Uz D � ISSUE I REVISIONS ID DATE DESCRIPTION CIT JUL PERMIT CENT ER CEiVFU TUKWILA 28 2017 Project No.: gtiNdi7ZA Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR REFLECTED CEILING PLAN - WEH-113 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:31 PM Sheet Size: 22"x34" (24"x36") I MEETING MEETING Mil ROOM 221 pror_111 1.11 ROOM 220 Pi 11111 mu _um imm, EN EN Elm =mom ILI, EN mil mu mi pm mil OPEN OFFICEgm mil I SECURED FILE STORAGE MEETING ROOM RTC INSTRUCTOR OFFICE BREAK ROOM COORIDOOR CONF ROOM MIN 1 1 1 1 SECOND FLOOR REFLECTED CEILING PLAN - EAST -114 SCALE : 1/4" = 1'-0" CEILING PLAN GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, ADDITIONAL DRAWING CONVENTIONS AND GENERAL NOTES. 2. REFERENCE SHEET A-601 FOR WALL AND CEILING ASSEMBLIES 3. ACOUSTICAL CEILING TILE GRIDS ARE TO BE CENTERED IN ROOMS UNLESS OTHERWISE NOTED. 4. LIGHT FIXTURES ARE TO BE CENTERED IN ACOUSTICAL CEILING TILE GRIDS AS INDICATED OR CENTERED IN ROOMS, UNLESS DIMENSIONED OTHERWISE. 5. DIMENSIONS FOR LIGHTS ARE TO FACE OF GYPSUM WALLBOARD AND TO CENTERLINE OF FIXTURE. 7. REFERENCE SHEET A-502 FOR TYPICAL ACT DETAILS. RCP LEGEND O 0 0 0.101 WEST WALL MOUNTED FIXTURE RECESSED LIGHT FIXTURE 2X4 ACT GWB CEILING RECESSED FIXTURE PER ELECTRICAL PENDANT FIXTURE PER ELECTRICAL EXISTING EXIT SIGN LOCATION EXIT SIGN LOCATION EXISTING WALL NEW PARTITION WALL ACCESS PANEL SUPPLY DIFFUSER RETURN DIFFUSER EAST SCALE: 1/4" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31. 2017 • City of Tukwit'a BUILDING MI= 0' 2' 4' 8' 16' PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & 'Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 011F11 EOORY .I. NESPOR TE OF WASHINGTON REGISTERED ARC I-IITEC T W Z U W Ce ED Liii 0 Oo ct ce m 0 ce °r+° a 0-3' ce O� .? i U W D F. upF- ISSUE / REVISIONS ID DATE DESCRIPTION J PER Kon L 28 2017 rr Project No.: p17ZA Drawn By: Author Checked By: Checker Sheet Title SECOND FLOOR REFLECTED CEILING PLAN EASE 114 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:32 PM Sheet Size: 22"x34" (24"x36") 5 PLAM COUNTERTOP \ 1 \ 1 \ 7 \ 1 \ ) \ 1 \ ) \ 1 \ 1 \ \ 1 \ 1 \ I\ \\ \\ \\ \\ \\ \\ \\I \ RECEPTION 107A - NORTH ELEVATION -401 SCALE : 1/2" = GRAB BAR RECESSED TOILET PAPER DISPENSER & SANITARY NAPKIN DISPOSAL BABY CHANGING STATION RM 132 - INT ELEV - NORTH -401 SCALE : 1/2" = 1'-0" 0 Ln WAINSCOT, TYP 2 Aik BABY CHANGING STATION RM 132 -INT ELEV - EAST -401 SCALE : 1/2" = 1'-0" MIRROR RECESSED PAPER TOWEL DISPENSER WASTE RECEPTACLE RM 132 - INT ELEV - SOUTH SCALE : 1/2" = INTERIOR ELEVATION GENERAL NOTES 1. MANUFACTURERS LISTED ARE NOT INTENDED TO LIMIT THE SELECTION OF EQUIVALENT MATERIALS, PATTERNS AND COLORS FROM OTHER MANUFACTURERS. EQUIVALENT MATERIALS MUST MEET THE REQUIREMENTS OF THE SPECIFICATIONS AND DRAWINGS. 2. SEE A-602 FOR INTERIOR FINISH SCHEDULE AND LEGEND 3. SEE A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, AND GENERAL NOTES 4. SEE A-002 FOR ACCESSIBILITY MOUNTING HEIGHTS AND DETAILS 1'-6" 4 RM 132 - INT ELEV - WEST MIRROR SOAP DISPENSER TOILET SEAT COVER DISPENSER REVIEWED FOR CODE COMPLIANCE APPROVED • AUG 31 2017 City of Tukwila BUILDING OIVISION -401 SCALE : 1/2" = 1'-0" SCALE: 1/2" =1'-0" bn o 1' 2' 4' PERMIT SET - JULY 21, 2017 L4,1 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative:. 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com *Olt 6431 A'EGORY 3. NESPOR STATE OF WASHINGTON REGISTERED ARC HITEC T KING COUNTY Vl I— LLIz U w Ce 2 D O > (1)O ce o oC cl. co O 1--1 03 • (,)0, a 00 CC s (f) >'S < o Uw Lr) Y I— �I- ISSUE / REVISIONS ID DATE DESCRIPTION cine ofENED L 28 2017 PEFiENT"ER Project No.: Po17ZA Drawn By: Author Checked By: Checker Sheet Title INTERIOR ELEVATIONS A-401 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 7/27/2017 1:29:33 PM Sheet Size: 22"x34" (24"x36") WALL TYPE PER PLAN PLASTIC SHIM AS REQUIRED SEALANT, BOTH SIDES ALUMINUM FRAME PER MFR DOOR PER SCHEDULE STOREFRONT DOOR @ HEAD -501 4 SCALE : 3" = 1'-0" ISEIENTIV 4/ WALL TYPE PER PLAN SEALANT, BOTH SIDES PLASTIC SHIM AS REQUIRED ALUMINUM FRAME PER MFR DOOR PER SCHEDULE STOREFRONT DOOR @ JAMB -501 SCALE : 3" = 1'-0" WALL TYPE PER PLAN PLASTIC SHIM AS REQUIRED SEALANT, BOTH SIDES ALUMINUM FRAME PER MFR GLAZING AS SCHEDULED /\// (STOREFRONT SIDELIGHT @ HEAD SCALE : 3" = 1'-0" WALL TYPE PER PLAN SEALANT, BOTH SIDES PLASTIC SHIM AS REQUIRED ALUMINUM FRAME PER MFR 11 \%\ DOOR PER SCHEDULE GLAZING AS SCHEDULED 5 STOREFRONT SIDELIGHT @ JAMB -501 SCALE : 3" = 1'-0" GLAZING AS SCHEDULED ALUMINUM FRAME SIDELIGHT SILL ATTACH PER MFR INSTALLATION DIRECTIONS PLASTIC SHIM AS REQUIRED SEALANT, BOTH SIDES WALL TYPE PER PLAN RESILIENT WALL BASE STOREFRONT SIDELIGHT @ THRESHOLD SCALE : 3" = 1'-0" CORNER GUARD, TYP EXISTING STRUCTURAL COLUMN TO REMAIN IN PLACE 2-1/2" LIGHT GAUGE METAL FRAMING 5/8" GYPSUM WALL BOARD 3 COLUMN FURRING -501 SCALE : 3" =11-0" BRACE FASTENED TO ROOF DECK WITH MIN (4) #10 SELF TAPPING SCREWS 400S150-33 FIELD FABRICATED METAL WALL BRACE @ 6'-0" O.C. AND WITHIN 2'-0" OF END OF TRACK OR TOP WALL TRACK SPLICE BRACE FASTENED TO TOP TRACK WITH MIN (4) #10 SELF TAPPING SCREWS 362T150-33 CONTI NUOUS TOP WALL TRACK #10 SELF TAPPING SCREWS EA FLANGE PARTIAL HEIGHT NON-STRUCTURAL INTERIOR METAL STUD WALL LINE OF ACT CEILING BELOW EXISTING ASSEMBLY NOTE: ALL NEWLY INSTALLED INTERIOR PARTITION WALLS TO MEET ASTM C-754 ATYPICAL PARTITION WALL CONNECTION TO DECK SCALE : 3" = 1'-0" PARTIAL HEIGHT NON-STRUCTURAL INTERIOR METAL STUD WALL 362S150-18 STUD TYP. .157" DIA POWER ACTUATED FASTENER @ 16" O.C. AND WITHIN 6" OF END OF TRACK #10 SELF TAPPING SCREWS EA FLANGE 362T150-18 CONTINUOUS FLOOR TRACK EXISTING FLOOR ASSEMBLY NOTE: ALL NEWLY INSTALLED INTERIOR PARTITION WALLS TO MEET ASTM C-754 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 City of Tukwila BUILDING DIVISION � TYPICAL PARTITION WALL CONNECTION TO FLOOR SCALE : 3" = 1'-0" opo � PERMIT SET -JULY 21, 2017 J. NESPOR ti.EGol!y ATE OF WASHINGTON L43 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 31 REGISTERED ARC HITEC T 0 m a w O z kr) co co ao 0 F H ISSUE / REVISIONS ID DATE DESCRIPTION Y 1 PER �F TUKWILA 128 2017 Project No.: o17ZA Drawn By: Author Checked By: Checker Sheet Title DETAILS A-501 C:1Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 7/27/2017 1:29:33 PM Sheet Size: 22"x34" (24"x36") 2" OR PER RCP'S 2 ATTACHED WALL MOLDING REQ'S ACT WALL MOLDING AND COUNTERSLOPING WALL 8" MAX. SPREADER BAR OR OTHER SUITABLE SYSTEM REQ'D TO KEEP PERIMETER COMPONENTS FROM SPREADING PART UNATTACHED WALL MOLDING REQ'S PLUMB 1/6 8" MAX. FIGURE A COUNTERSLOPING FIGURE B -502 SCALE : 6" =11-0" 12 GAUGE SPLAYED BRACE WIRES LATERAL FORCE BRACING SCALE : 3" = 1'-0" 11 1 111 1111 III 1111 111111II1P 4 TYPICAL ACT AT HEADER 3 FASTENER CEILING STRUCTURE CEILING CLIP 3 TURNS VERTICAL HANGAR WIRE 5/8" MAX. M VERTICAL HANGER WIRE ATTACHEMENT WIRE ATTACHEMENT DETAILS FASTENER CEILING STRUCTURE STEEL STRAP 1" WIDE x 2" LONG x 12 GAGE MINIMUM 3 TURNS SPLAYED SEISMIC BRACING WIRE SPLAYED SEISMIC BRACING WIRE ATTACHMENT WALL TYPE PER PLAN CORNER BEAD, TYP ACOUSTICAL TILE CEILING SEE RCP FOR HEIGHT -502 -502 SCALE : 3" = 1'-0" SCALE : 12" = 1'-0" p �7 0) -Of SCALE: 3" =1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 31 2011 City of Tut wi(a BUILDING DLVIS 0' 2" 4" SCALE: 6" =1'-0" 8" 1'4' 0' 1" 2" 4" PERMIT SET - JULY 21, 2017 slg King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 41111,; 4rEGORY J. NESPOR STATE OF WASHINGTON (5431 REGISTERED ARC HITEC T KING COUNTY -- I— LL! Z U w oC 2 D W 0> up J 1..6. cL CO co 0 i ce� CL al Z > a'S _ a. L F— '.01— ISSUE/REVISIONS ID DATE DESCRIPTION C nEcovED If OF 28 2017 P Project No.: t!o17ZA Drawn By: Author Checked By: Checker Sheet Title TYPICAL ACT DETAILS A 502 LA C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central_ssmith@wja-dc.com.rvt 0 co r— N ti Sheet Size: 22"x34" (24"x36") 105 EXISTING DOOR SCHEDULE Mark 3'-0" Rough Width Rough Height Door - Width Door - Height EXISTING FRAME DETAILS Glazing Fire Rating Hardware Group Comments Door - Type Door Thickness Door Material Door Finish Frame Type Frame Materia I Frame Finish Head Detail Jamb Detail Sill/Threshold Detail 105 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 ADA DOOR ACTUATOR BOTH SIDES, ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 106 EXISTING 6'-4" 7'-4" 6'-0" 7'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 107A 2 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" ALUM ANODIZED A ALUM ANODIZED 1/A-501 4/A-501 - GL -1 ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 107B EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 107C 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 108 1 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - - INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION, ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 108A EXISTING 31-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 109 2 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" ALUM ANODIZED C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 110 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 111 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 111A EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 112 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 113 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 114 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 115 EXISTING 8'-0" 6'-8" 8'-0" 6'-8" 1 3/4" - - EXISTING - - - - - - - HW -1 116 2 31-4" 8'-2" 3'-0" 8'-0" 1 3/4" ALUM ANODIZED EXISTING - ANODIZED - - - GL -1 - 117 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 118A 3 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 - - GL -2 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 118B 3 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD EXISTING ALUM ANODIZED - - - GL -2 119 1 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS FROM STAIRWELL 120 1 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 121A EXISTING 2'-8" 7'-4" 2'-4" 7'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 123 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - HW -1 126 EXISTING 31-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 127 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 - 128 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 129 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 130A 3 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - GL -2 130B 3 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - GL -2 131 1 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 131A 1 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - 132 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 202 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 203 EXISTING 6'-4" 7'-4" 6'-0" 7'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 203B 2 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" ALUM ANODIZED A ALUM ANODIZED 1/A-501 4/A-501 - - 204 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 206 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 207 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION 208 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 209 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 ADA DOOR ACTUATOR BOTH SIDES, ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 210 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 - 210A EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 211 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 212 1 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" WD C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 213 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS FROM STAIRWELL 214 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 215A EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 215B EXISTING 2'-10" 7'-4" 2'-6" 7'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 216 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 217 EXISTING 3'-4" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 218 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 — 219 2 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" ALUM ANODIZED C ALUM ANODIZED 1/A-501, 2/A-501 4/A-501, 5/A-501 8/A-501 GL -1 ELECTRIFIED DOOR STRIKE FOR CARD KEY ACCESS 220 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 221 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 P REVIEWED FOR 222 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 ; CODE COMPLIANCE 223 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 224 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 3 225 EXISTING 5'-0" 8'-2" 3'-0" 8'-0" 1 3/4" - - EXISTING - - - - - - - HW -1 226 1 6'-4" 7'-4" 6'-0" 7'-0" 1 3/4" WD B ALUM ANODIZED 1/A-501 4/A-501 - GL -1`` City Cif'Ctlkwtla 227 1 31-4" 8'-2" 3'-0" 8'-0" 1 3/4" WD A ALUM ANODIZED 1/A-501 4/A-501 - - INSTALL SALVAGED DOOR & FRAME FROM DEMOLITION ' BUILDING DikitStOiSi 1 2 DOOR PANEL LEGEND 3 SCALE : 1/4" = 1'-0" • 2" 2" 0 W 2 WIDTH( PER SCHEDULE A PER SCHEDULE f2" 2" WIDTH PER SCHEDULE B DOOR FRAME LEGEND 2" SCALE : 1/4" = 1'-0" '_6" 0 W j(WIDTHI PER SCHEDULE C PER SCHEDULE PERMIT SET - JULY 21, 2017 ,01 'EGORY J. NESPOR STATE OF WASHINGTON King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 REGISTERED ARC HITEC T KING COUNTY 0 -J CO Qco a. 00 crl >: 0 Z� Lt) vD ISSUE / REVISIONS ID DATE DESCRIPTION P, Project No.: t!o17ZA Drawn By: Author Checked By: Checker Sheet Title DOOR SCHEDULES & LEGENDS A-601 C:\Users\Shane Smith\Documents\DCHS Renton Worksource - 2017 Central ssmith@wja-dc.com.rvt 7/27/2017 1:29:35 PM Sheet Size: 22"x34" (24"x36") WALL TYPES LEGEND S147/8" Interior '.,_ GENERAL NOTES 1. REFERENCE SHEET A-001 FOR ABBREVIATIONS, SYMBOL LEGENDS, DRAWING CONVENTIONS AND GENERAL NOTES 2 ABUSE RESISTANT GYPSUM WALL BOARD SHALL BE USED IN ALL CORRIDORS. SEE FINISH PLANS FOR ADDITIONAL INFORMATION REGARDING PAINT, ETC 2. REFER TO SHEETS A-101 TO A-104, FOR LOCATIONS OF WALL TYPES ,' 5/8" GWB?-_ADDITIONAL 3 5/8" METAL STUD @ 16" O.C. W/ 3-1/2" SOUND BATTS '' 5/8" GWB S2 Interior 6" METAL STUD @ 16" OC 5/8" GWB REVIEWED FOR ODE COMPLIANCE APPROVED AUG 31 2017 City of Tukwila BUILDING DIVISION PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 4.4121.1132P -- design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com 6431 REGISTERED ARC HITEC T 4rEGORY 3. NESPOR STATE OF WASHINGTON KING COUNTY W ~ U z w O> CO 0 Ce O� F- < =z oI— ISSUE / REVISIONS ID DATE 1 DESCRIPTION en' JUMio(I 1 WE inKWiut 2017 Project No.: t'io17ZA Drawn By: Author Checked By: Checker Sheet Title FLOOR, WALL & CEILING ASSEMBLIES A-602 GENERAL LEGEND NORTH ARROW DETAIL, DRAWING REFERENCE SECTION REFERENCE CONSTRUCTION NOTE BOLD LINE WEIGHT INDICATES NEW WORK LIGHT LINE WEIGHT INDICATES EXISTING SLASHED LINE INDICATES EXISTING WORK TO BE DEMOLISHED OR ABANDONED AS INDICATED ON PLANS VENTILATION LEGEND SINGLE LINE DUCTWORK INDICATES VIEW DIMENSION LESS THAN 12 INCHES I +--® + I D.1 1 " } I Cxl + I V 4 3 FD TV� 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") SUPPLY OR EXHAUST TAKEOFF SUPPLY DUCT TURNING TOWARD SUPPLY DUCT TURNING AWAY EXHAUST DUCT TURNING TOWARD EXHAUST DUCT TURNING AWAY ROUND DUCT TURNING TOWARD I C) ROUND DUCT TURNING AWAY TRANSITION D—+ t=R=2.) 0 121 z F-1 SMOKE DAMPER MOTORIZED DAMPER VOLUME DAMPER FIRE DAMPER HUMIDIFIER ACCESS DOOR, ACCESS PANEL FLEXIBLE CONNECTION TURNING VANES FLEXIBLE DUCT 2'x2' SUPPLY DIFFUSER 2' DIAMETER SUPPLY DIFFUSER 1'x2' EXHAUST GRILLE 2'x2' EXHAUST GRILLE 2'x4' EXHAUST GRILLE THERMOSTAT EQUIPMENT TAG ABV AD ADDN AFF ALT AP APPROX ARCH AUX BAL BLDG BTU BTU H CAP CL CLG COND COL CONN CONST CONT CONTR COORD DEG DIA DIAG DIFF DIM DISCH DIV DN DP DR DWG EA EFF ELEC ELEV EMCS ENT EQ EQUIP EX, (E) EXP F FIN FLEX FLR FP FT GA GAL GC GEN GPM GWB H HOR HP HR HZ IBC ID IMC IN INFO INSUL KW KWH L LAV LB GENERAL ABBREVIATIONS ABOVE ACCESS DOOR ADDITION, ADDITIONAL ABOVE FINISHED FLOOR ALTERNATE ACCESS PANEL APPROXIMATELY ARCHITECT; ARCHITECTURAL AUXILIARY BALANCING BUILDING BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CENTERLINE CEILING CONDENSATE COLUMN CONNECT; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION CONTRACTOR COORDINATE DEGREE DIAMETER DIAGRAM DIFFERENTIAL DIMENSION DISCHARGE DIVISION DOWN DIFFERENTIAL PRESSURE DRAIN DRAWING EACH EFFICIENCY ELECTRICAL ELEVATION ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUAL EQUIPMENT EXISTING EXPOSED FAHRENHEIT FINISHED FLEXIBLE FLOOR FIRE PROTECTION; FREEZE PROTECTION FEET; FOOT; FEET OF WATER(PRESS) GAGE; GAUGE GALLON GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GYPSUM WALLBOARD HEIGHT; HIGH HORIZONTAL HORSE POWER HOUR HERTZ INTERNATIONAL BUILDING CODE INSIDE DIAMETER INTERNATIONAL MECHANICAL CODE INCH INFORMATION INSULATE; INSULATION KILOWATT KILOWATT HOUR LENGTH; LONG (DIM) LAVATORY POUND LBS/HR LF LO LTG LVG MAT MAX MBH MCC MECH MED MFG MFR MIN MISC MTD MTG MTL N NA NC NIC NO NOM NTS OC OD OPP PD PERF PERP PH POC PRELIM PRESS PROP PSI QTY QUANTITY POUNDS PER HOUR LINEAL FEET LOW LIGHTING LEAVING MATERIAL MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MOTOR CONTROL CENTER MECHANICAL; MECHANICAL CONTRACTOR MEDIUM MANUFACTURING MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOUNTED MOUNTING METAL NORTH NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER; OVERALL DIMENSION OPPOSITE PRESSURE DROP PERFORATED PERPENDICULAR PHASE POINT OF CONNECTION PRELIMINARY PRESSURE PROPERTY; PROPOSAL POUNDS PER SQUARE INCH R REF REQD RET RM RPM S SCHED SECT SF SHT SIM SPEC SPECD SQ STD STRUCT TBD TD TEMP TH THRU TYP UBC UL UTI L RADIUS; RETURN; RISER REFERENCE REQUIRED RETURN ROOM REVOLUTIONS PER MINUTE SOUTH SCHEDULE SECTION SQUARE FEET SHEET SIMILAR SPECIFICATION SPECIFIED SQUARE STANDARD STRUCTURAL TO BE DETERMINED TEMPERATURE DIFFERENTIAL TEMPERATURE TOTAL HEAD THROUGH TYPICAL UNIFORM BUILDING CODE UNDERWRITER'S LABORATORY UTILITY V VOLT VAR VARIABLE VEL VELOCITY VERT VERTICAL VOL VOLUME W W/ W/O WT YD YR WATER; WIDE(DIM); WATT WITH WITHOUT WEIGHT YARD YEAR HVAC ABBREVIATIONS AL AC AHU BDD BHP BOD C CC CFM CG CLG COND DDC DMPR DB EA EAT EF EG EXH FA FD FPM GALV GR HC HTG LAT MA OA OAT OSA RA RG S SFD SP SD SA SF SG SR T, TSTAT TG VAV VENT VD WG WB ACOUSTIC LINED; ALUMINUM AIR CONDITIONING AIR HANDLING UNIT BACKDRAFT DAMPER BRAKE HORSEPOWER BOTTOM OF DUCT CONDENSATE; COMMON COOLING COIL CUBIC FEET PER MINUTE CEILING GRILLE COOLING CONDENSATE DIRECT DIGITAL CONTROLS DAMPER DRY BULB TEMPERATURE(T) EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST FAN EXHAUST GRILLE EXHAUST FACE AREA FIRE DAMPER FEET PER MINUTE GALVANIZED GRILLE HEATING COIL HEATING LEAVING AIR TEMPERATURE MIXED AIR OUTSIDE AIR OUTSIDE AIR TEMPERATURE OUTSIDE AIR RETURN AIR RETURN GRILLE SUPPLY SMOKE/FIRE DAMPER STATIC PRESSURE SMOKE DAMPER; SUPPLY DIFFUSER SUPPLY AIR; SOUND ATTENUATOR SUPPLY FAN SUPPLY GRILLE SUPPLY REGISTER THERMOSTAT TRANSFER GRILLE VARIABLE AIR VOLUME VENTILATE; VENTILATION VOLUME DAMPER WALL GRILLE WET BULB TEMPERATURE(°F) MECHANICAL DRAWING INDEX M-000 M-001 MD -101 MD -102 M-101 M-102 M-400 M-500 LEGEND, ABBREVIATIONS AND NOTES HVAC SCHEDULES FIRST FLOOR PLAN — HVAC DEMO SECOND FLOOR PLAN — HVAC DEMO FIRST FLOOR PLAN — HVAC SECOND FLOOR PLAN — HVAC SEQUENCE OF OPERATIONS AND POINTS LIST HVAC DETAILS MECHANICAL GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE NEW MECHANICAL/ELECTICAL SCOPE OF WORK PRIOR TO WORK. 2. UNLESS OTHERWISE NOTED, REMOVE ALL ABANDONED PIPING, CONTROLS, WIRING, ETC., WHERE ACCESSIBLE IN RENOVATED AREAS. NO ABANDONED IN PLACE MATERIALS ARE ALLOWED IN RENOVATED AREAS. 3. WHERE CONTROLS ARE DEMOLISHED, REMOVE WIRING BACK TO NEAREST CONTROL PANEL OR JUNCTION BOX. REMOVE ACCESSIBLE CONDUIT, JUNCTION BOXES, ETC. 4. CONTRACTOR TO CLEAN AND PROTECT WORK FROM DAMAGE, RESTORE DAMAGED FINISHES AND COVER ENDS OF PIPING NOT ACTIVELY BEING WORKED ON. 5. CONTRACTOR SHALL NOT CUT ANY STRUCTURAL ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL. 6. CONTRACTOR TO DELIVER, HANDLE AND STORE MATERIALS PER MANUFACTURER'S RECOMMENDATION. 7. MAINTAIN AND RESTORE (IF INTERRUPTED ALL CONDUITS AND CONDUCTORS, PIPING, AND DUCTWORK PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS. 8. COORDINATE ALL MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF MECHANICAL CONTRACTOR. PROVIDE COORDINATED SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. 9. SEISMIC PROVISIONS SHALL BE PROVIDED WHERE REQUIRED IN ACCORDANCE WITH LOCAL CODES. 10. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND CONSTRUCTION FEES. FURNISH FINAL CERTIFICATE TO OWNER SHOWING COMPLIANCE WITH CODE REQUIREMENTS. 11. REMOVE ONLY AMOUNT OF CEILING SYSTEM THAT CAN BE REINSTALLED OR REPAIRED BEFORE THE END OF WORK EACH DAY. EXPOSED ABOVE—CEILING AREAS ARE PROHIBITED OUTSIDE OF ACTIVE CONSTRUCTION HOURS. 12. REPLACE ANY CEILING TILES AND SECTIONS OF CEILING GRID DAMAGED DURING CONSTRUCTION. MATCH EXISTING. CUT MAINS OF SUSPENDED CEILING SYSTEM TO BE REPLACED BY CONTRACTOR. 13. WORK HOURS TO COINCIDE WITH OFFICER WORK SHIFTS. WORK HOURS TO BE COORDINATED WITH APPROPRIATE FACILITIES STAFF NO LESS THAN 30 DAYS PRIOR TO CONSTRUCTION. 14. NOTIFY AND COORDINATE CONSTRUCTION WORK WITH OWNER AND KC DCHS. 15. COORDINATE WORK WITH BUILDING OWNER TO AVOID FALSE TRIPPING OF SMOKE DETECTORS DURING CONSTRUCTION. PROTECT DETECTORS FROM DAMAGE/DEBRIS BY USING VACUUM TO COLLECT DEBRIS AND DUST CREATED DURING DRILLING, CUTTING, SANDING, ETC. 16. DUCT SIZING IS ESTIMATED. ALL DUCT SIZES TO BE VERIFIED BY CONTRACTOR. fli7- 0201 SEPARATE A :' r1rAND ti SAL REQUIRED 90% SUBMITTAL - JULY 20, 2017 King My Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com P SIGNED FSi consulting engineers Seattle, Washington Solutions & Service 0 CO CO 9r9 coa W O� 0 -J z1-1 Q Ln � �I— ISSUE / REVISIONS ID DATE DESCRIPTION CITyR� r►VED uxw►tA JUL 28 2017 Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title LEGEND, ABBREV., AND NOTES 000 EXHAUST FA\ SCHEDULE CALLOUT LOCATION FAN TYPE SERVICE FAN MAX SOUND LEVEL BASIS OF DESIGN NOTES TYPE MARK CFM DRIVE TYPE STATIC PRESSURE (IN WC) [1] RPM FEG [4] MOTOR MANUFACTURER MODEL RPM HP EF 1 RESTROOM CEILING INLINE RESTROOMS 100 BELT 0.50 950 67% 950 80 W 25 GREENHECK FAN SP—B110 [2], [3] _SCHEDULE NOTES: 1 STATIC PRESSURE EXTERNAL TO FAN. 2 PROVIDE WITH INITIAL SET OF SHEAVES FOR FAN TO MEET CONDITIONS AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT SET OF SHEAVES FOR FAN ACTUAL CONDITIONS, REGARDLESS OF WHETHER CONSTANT OR VARIABLE SPEED. 3 AS RATED PER AMCA 205 4 PROVIDE WITH ECM MOTOR AND VARIABLE SPEED CONTROLLER. TERMINAL BOX SCHEDULE MARK SERVICE CFM DUCT CONNECTIONS ECM FAN HP HEAT CFM REHEAT COIL (1) MAKE AND MANUFACTURER REMARKS INLET SIZE 0 OUTLET WIDTH OUTLET HEIGHT TOTAL KW # OF STEPS V/PH/HZ MAX MIN VAV-6-211 MEETING RM 206 &207 500 150 8" 12" 10" 1/3 150 3.0 1 277/1/60 ENVIRO—TEC CFR—EH 0811 [2] SCHEDULE NOTES: [1] PROVIDE WITH FACTORY MOUNTED 24V TRANSFORMER. 1_2J MAINTAIN ALL MANUFACTURER REQUIRED CLEARANCES 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") b rim? c)-0 SEPARATE PERMITAND APPROVAL REQUIRED 90% SUBMITTAL - JULY 20, 2017 King nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED • FSi consulting engineers Seattle, Washington Solutions & Service TENANT IMPROVEMENTS 0 m co cc co a. L11 >. > o� J Q L ISSUE / REVISIONS ID DATE DESCRIPTION °/eFit o �IV�e0 ���witA Jut 2 8 2011 PeRM Nren Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title HVAC SCHEDULES M 001 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") ATRIUM N L9 -1, 1 iI VAV-6-110 i� • OBB'i 2x12 16x12 Ilryv .( �1r ifs (ADULT/V171 12x12' -VAV—`6;-11 2A VAV-6-116 -- VAV-6-101 SE VAV-6— 2x1 2 l?! .i01) RCP: 10"0 /16x12 i' 2/: n 3, VAV-6-113 HNC VAV— 6 —104 16x12 co,�:.. 1) FIRST FLOOR PLAN - HVAC DEMO 1/8" =1'-0" GE\E AL \OTES: 1. DUCT SIZING TO BE VERIFIED BY CONTRACTOR (TYP.). DE V OLITIO\ OYES: REMOVE RETURN GRILLE AND PRESERVE FOR RE—USE. PROVIDE TEMPORARY CAP REMOVE THERMOSTAT AND PRESERVE FOR RE—USE. REMOVE DUCTWORK AS SHOWN. PROVIDE TEMPORARY CAP. bra/ o SCALE: 1/8" =1'-0" SEPA PERM i mr,un.r/r�ttvai7//'//,/'/ :a///Y"*://7/s, )7/E�".'�u \/7///./`.}/;.x}} t Y�r�kJ//W&C/lUis S7}• .;�t ' 4S„#;; iF\�=r.(� R R -?UI 16' NORTH 90% SUBMITTAL - JULY 20, 2017 King Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SICNED • FSi consulting engineers Seattle, Washington Solutions & Service TENANT IMPROVEMENTS 0 m c0 cc co � Q W O � O J ZLn Y ISSUE / REVISIONS ID DATE DESCRIPTION OF T to L 2 8 2017 PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title FIRST FLOOR PLAN - HVAC DEMO MD -101 Si 1 ___L I IN,C .ter,, UHT i -i ii I E^, v�H rdl >i VAV-6-210ObVAV-6-209 J VAV-6-203 I VAV- LIBRARY V Yl C- Fi L I 06.: 50. I- T. MPU v.13:1-11,,.C1, ;4404>< 17. RC 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") --- SECOND FLOOR PLAN - HVAC DEMO 1/8" =1'-0" -------------------------- <i GE\HAL \OTES: 1. DUCT SIZING TO BE VERIFIED BY CONTRACTOR (TYP). EvOLITIO\ \DYES: REMOVE RETURN GRILLE AND PRESERVE FOR RE—USE. PROVIDE TEMPORARY CAP. REMOVE SUPPLY DIFFUSER AND PRESERVE FOR RE—USE. PROVIDE TEMPORARY CAP. REMOVE THERMOSTAT AND PRESERVE FOR RE—USE. DEMO DUCTWORK BACK TO MAIN TRUNK AS SHOWN. br7 0201 SCALE: 1/8" =1'-0" SEPA PER PP E NORTH 90% SUBMITTAL - JULY 20, 2017 King nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED FSi consulting engineers Seattle, Washington Solutions & Service TENANT IMPROVEMENTS ISSUE / REVISIONS ID DATE DESCRIPTION CITY E1V� C�Uf`A JUL 2 8 2017 PERMIT CSVT E'R Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SECOND FLOOR PLAN - HVAC DEMO MD 102 F 1'11 . /.ir:N; T O R 6 "0 .0 », 2x 12 i D VAV-6-112A' E)8" :ori;- 'ESTR00�:' 1i)<f VAV-6-101 VAV— 6 —103 (E)12x12 12x12 VAV-6 -106 VAV-6-113 VAV— 6 —107 Li.. I INC, R00r IC) ,L- -VAV— 6 —1\04 E)16x12 1 I L \-(E)16x12 (E)12k12 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") FIRST FLOOR PLAN - HVAC 1/8" =1'-0" GE\ HAL \OTES: DUCT SIZING TO BE VERIFIED BY CONTRACTOR (TIP). 2. BALANCE ALL ZONES TO AIRFLOW VALUES SHOWN. CO \STUCT 0\ \OTES: INSTALL SALVAGED RETURN GRILLE IN LOCATION SHOWN. PROVIDE THERMOSTAT IN LOCATION SHOWN. LOCATE APPROXIMATELY AT 48" AFF. RECONFIGURE THERMOSTATS SERVING SAME ZONE TO BE SET TO THE SAME TEMPERATURE SETPOINT. PROVIDE EXHAUST FAN AND TIE TO EXISTING EXHAUST DUCTWORK LOCATED IN THE BATHROOM AREA. CONTRACTOR TO VERIFY. p r-7 oio SCALE: 1/8" = 1'-0" SEPA PER PP EQ 4' 8' 16' NORTH 90% SUBMITTAL - JULY 20, 2017 JUI King awnty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED FSi consulting engineers Seattle, Washington Solutions & Service u) tU .. z 6 W W 9 U5 m rY W OO 0,21 ?' (/) CC %co 01 Z Cl. lit Q O O'1. O 0�Q z� z 1 Z < 1.-1U w Ln D I— F - ISSUE / REVISIONS ID DATE DESCRIPTION RrEee CITY OF r, �•���� JUL 2 82017 P E R MENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title FIRST FLOOR PLAN - HVAC M-101 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36°) T, M_ -11 C :±:c LC:EMI RES1 ON r 1 LE ,( VAV-6-209 fRES?ROON) ii VAV-6-203 coRploorz 300 pEsouper CFM AND COMPUTERS [:i 150 CFM 1EETir;,: m,.., UP TO RTU 1300 CFM o 300 CFM VAV-6-208; ..AWN VAV4-202 x 200 CFM (TYP. 6) VAV-6-20 f.ETIr,i3 50 CFM P'' MJ 10"0 300 CFM rkl A d I T 1 t— L 200 CFM 200 CFM 10" 0 SECOND FLOOR PLAN - HVAC 1/8" =1'-0" C GES HAL \OTES • • 1. DUCT SIZING TO BE VERIFIED BY CONTRACTOR (TYP). 2. BALANCE ALL ZONES TO VALUES AIRFLOW VALUES SHOWN. CO\SRUCTIO\ \OTES: INSTALL SALVAGED RETURN GRILLE IN LOCATION SHOWN. PROVIDE THERMOSTAT IN LOCATION SHOWN. LOCATE APPROXIMATELY AT 48" AFF. RECONFIGURE THERMOSTATS SERVING SAME ZONE TO BE SET TO THE SAME TEMPERATURE SETPOINT. PROVIDE RETURN GRILLE AND CONNECT WITH FLEX DUCT AS SHOWN. GRILLES TO MATCH EXISTING. RELOCATE THERMOSTAT TO LOCATION SHOWN. CONNECT THERMOSTAT TO RELATED UNIT. BALANCE DIFFUSER TO CFM INDICATED. PROVIDE DIFFUSER AND CONNECT TO DUCTWORK AS SHOWN. BALANCE DIFFUSER TO CFM INDICATED. DIFFUSERS TO MATCH EXISTING. 02.01 NORTH 90% SUBMITTAL - JULY 20, 2017 King rrty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Ma'n St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SICNBD FSi consulting engineers Seattle, Washington Solutions & Service ISSUE / REVISIONS ID DATE DESCRIPTION eITV of T� Eo KWILA JUL 2 8 2017 PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SECOND FLOOR PLAN - HVAC M-102 TRANE 50–TON DX COOLING, NATURAL GAS HEATING. TRANE 4–TON DX COOLING, NATURAL GAS H EATI N G TRANE 10–TON DX COOLING, NATURAL GAS HEATING TRANE 5–TON DX COOLING, NATURAL GAS HEATING 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") ROOF PLAN - HVAC 1/8" =1'-0" 0201 NORTH FOR REFERENCE ONLY 90% SUBMITTAL - JULY 20, 2017 tity Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SICNRD 0 FSi consulting engineers Seattle, Washington Solutions & Service .. z 6 W W 0 U E m OC LU O O ,-I (1) Ce %cO � a. a Q O �, O�z g � U1 U(1)< Z Z_Z < ...... U W d--� SOH �1— ISSUE / REVISIONS ID DATE DESCRIPTION JUL FERMI T NTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title ROOF PLAN - HVAC M 103 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") SEQUE\CE OF OPEATIO\: VAV BOX OPERATION: START/STOP AND MORNING WARMUP WHEN AN AHU IS ENABLED, THE DDC SHALL ALSO ENABLE THE FAN IN THE VAV BOX SERVED BY THAT AHU. DURING OCCUPIED MODE, THE VAV BOX FAN SHALL RUN CONTINUOUSLY. DURING MORNING WARMUP, VAV BOX SHALL GO TO FULL HEATING AND FULL RECIRCULATION. AS THE SPACE TEMPERATURE REACHES 70 DEG F, THE DDC SYSTEM SHALL RESUME VAV BOX TEMPERATURE CONTROL AS DESCRIBED BELOW. TEMPERATURE CONTROL THE TEMPERATURE SENSOR SHALL RESET THE BOX DISCHARGE TEMPERATURE TO MAINTAIN THE SPACE SET POINT. AS THE CALL FOR COOLING INCREASES, THE DDC SHALL OPEN THE BOX PRIMARY AIR DAMPER. AS THE CALL FOR COOLING DROPS, THE DDC SHALL CLOSE THE BOX PRIMARY AIR DAMPER. AS THE PRIMARY AIR DAMPER REACHES ITS MINIMUM SETTING AND THERE IS A CONTINUED DROP IN CALL FOR COOLING (A CALL FOR HEATING), THE DDC SHALL MODULATE THE TERMINAL AUXILIARY HEATER TO MAINTAIN THE SPACE SETPOINT. NIGHT SETBACK WHEN IN UNOCCUPIED MODE AND ANY SPACE TEMPERATURE DROPS TO 60 DEG F (ADJUSTABLE), THE DDC SHALL CALL FOR HEATING IN THAT ZONE. THE FAN IN THE BOX CALLING FOR HEATING SHALL START, THOSE PRIMARY AIR DAMPERS SHALL GO TO MINIMUM PRIMARY AIR POSITION AND THE HEATING COIL CONTROL VALVE SHALL GO FULL OPEN. AS THE INDIVIDUAL SPACE TEMPERATURES REACH 70 DEG F, THE SATISFIED ZONE FANS SHALL STOP AND THE CONTROL VALVES SHALL CLOSE. EXHAUST FAN OPERATION: WHEN THE AHU NEAREST A TOILET ROOM IS COMMANDED TO 'OCCUPIED" BY THE DDC SYSTEM, THE TOILET ROOM EXHAUST FAN SHALL RUN CONTINUOUSLY. WHEN THE AHU STOPS OR GOES TO `UNOCCUPIED", THE DDC SYSTEM SHALL DISABLE THE ASSOCIATED EXHAUST FAN. POI\TS LIST BUILDING CONTROL SYSTEM POINT SUMMARY ANALOG INPUTS ANALOG OUTPUTS DIGITAL INPUTS DIGITAL OUTPUTS ALARMS REMARKS SYSTEM NAME: GENERAL DESCRIPTION: BUILDING OCCUPIED/UNOCCUPIED SCHEDULE X SCHEDULE FOR EACH OF THE AIR UNITS SYSTEM NAME: VAV BOX/SPACE CONTROL DESCRIPTION: TYPICAL OF EACH BOX/SPACE SPACE TEMPERATURE X X LOW TEMP ALARM SPACE TEMPERATURE ADJUST X X FAN START/STOP X FAN PROOF X X CURRENT SENSING RELAY DAMPER MODULATION X AIR FLOW (CFM) X X UNIT DISCHARGE TEMPERATURE X X SYSTEM NAME: EXHAUST DESCRIPTION: TYPICAL OF EACH FAN FAN START/STOP X FAN PROOF X CURRENT SENSING RELAY r7 020 SEPARATE PERMIT AND APPROVAL REQUIRED 90% SUBMITTAL - JULY 20, 2017 Kim My Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNND FSi consulting engineers Seattle, Washington Solutions & Service TENANT IMPROVEMENTS 0 CO SCO oC co a 0C aC W On 0 J qD ISSUE / REVISIONS ID DATE DESCRIPTION CiTYR KWILA JUC 2 8 2017 PCItivirr TER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SEQUENCE OF OPERATIONS & POINTS LIST M-400 FLEX DUCT, MAX 6' rTAP-IN LENGTH in- 3" n 4" / EQUAL EQUAL q_ FLEX DUCT - PERFORATED METAL DIAMOND #341 OR EQUAL, 5/32" DIA HOLES ©3/16" WITH 65% OPEN AREA. 22 OR 24 / GAUGE COLD ROLLED 24 GA SHEETMETAL DIFFUSER CAN SQUARE -NECK DIFFUSER 1 1 /2" CAN SIZE TO SLIP OVER DIFFUSER NECK LAY -IN CEILING SHOWN, FRAME -MOUNT TO "HARD" CEILINGS SIZING CHART CFM RANGE DIFFUSER NOMINAL NECK SIZE TAP -IN BASIS OF DESIGN THROW AT 100 FPM (FT) [11 NC [2] 0-125 6" x 6" 8"0 TITUS MCD 7 <10 125-225 8" x 8" 8"0 TITUS MCD 9 12 225-350 10" x 10" 10"0 TITUS MCD 12 17 350-475 12" x 12" 12"O TITUS MCD 14 19 475-675 14" x 14" 14'10 TITUS MCD 16 23 675-850 16" x 16" 14"0 TITUS MCD 19 25 850-1100 18" x 18" 16"0 TITUS MCD 21 28 [1] AT ISOTHERMAL CONDITIONS. [2] MAX FOR EACH OCTAVE BAND WITH 10dB ROOM ABSORPTION. SQUARE -NECK SUPPLY DIFFUSER DETAIL SCALE: NONE 1b15( 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") 0 24" LONG GALV STEEL CAN WITI 11 " LINING WIDTH r EGGCRATE GRILLE FLEX DUCT, MAX 6' LENGTH, DIAMETER AS SCHEDULED EXCEPT AS NOTED OTHERWISE ON PLANS 6. LAY -IN CEILING SHOWN, FRAME -MOUNT TO "HARD" CEILINGS SIZING CHART CFM RANGE NOMINAL GRILLE SIZE, LENGTH x WIDTH D BASIS OF DESIGN 0-400 24" x 6" 10"0 TITUS 5OF 401-799 24" x 12" 12"0 TITUS 50F 800-1199 24" x 18" 14"0 TITUS 50F DUCTED RETURN AIR GRILLE DETAIL SCALE: NONE D �7� 0)-a SCALE: 1/8" =1-0" SEPA ER PP 4' 8' 16' Q NORTH 90% SUBMITTAL - JULY 20, 2017 King • Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED • FSi consulting engineers Seattle, Washington Solutions & Service (.6 0 J CO CO Ce co �c Q LU > o� OJ z1-4 <Ln� 'oH ISSUE / REVISIONS ID DATE DESCRIPTION —TUKALA L28 2017 PEJ Mrr TER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title HVAC DETAILS M-500 GENERAL LEGEND PLUMBING LEGEND z'//////1 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") NORTH ARROW DETAIL, DRAWING REFERENCE SECTION REFERENCE CONSTRUCTION NOTE BOLD LINE WEIGHT INDICATES NEW WORK LIGHT LINE WEIGHT INDICATES EXISTING SLASHED LINE INDICATES EXISTING WORK TO BE DEMOLISHED OR ABANDONED AS INDICATED ON PLANS r--- ---� XX + 1 DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) DOMESTIC HOT WATER CIRCULATING (HWC) SOIL, WASTE (S,W) —� VENT (V) PIPING IDENTIFIER, SEE ABBREVIATIONS 0 ELBOW DOWN o ELBOW UP TEE 4 + TEE DN + TEE UP ANGLE VALVE lel D4 DUI + ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS SPECIFIED ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS SPECIFIED THROTTLING VALVE, TYPE AS SPECIFIED BALANCING VALVE METERING BALANCING VALVE CHECK VALVE CONTROL VALVE 3—WAY CONTROL VALVE ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS SPECIFIED ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS SPECIFIED THROTTLING VALVE (NO), TYPE AS SPECIFIED THROTTLING VALVE (NC), TYPE AS SPECIFIED PLUG VALVE PRESSURE REDUCING VALVE SOLENOID VALVE ANGLE VALVE(PLAN VIEW) CAP BLIND FLANGE EXPANSION JOINT REDUCER PRESSURE GAUGE STRAINER UNION : + AIR VENT, TYPE AS SPECIFIED : T + PRESSURE/TEMPERATURE TAP + + TEMPERATURE GAUGE PLUMBING ABBREVIATIONS PLUMBING DRAWING INDEX CO CLEAN OUT FCO FLOOR CLEAN OUT FD FLOOR DRAIN GPH GALLONS PER HOUR HW DOMESTIC HOT WATER IPC INTERNATIONAL PLUMBING CODE L LAVATORY PLBG PLUMBING SS SANITARY SEWER UPC UNIFORM PLUMBING CODE V VENT VTR VENT THRU ROOF W WC WASTE WATER CLOSET P-000 P-001 PD -102 P-101 P-102 LEGEND, ABBREVIATIONS AND NOTES PLUMBING SCHEDULES SECOND FLOOR PLAN — PLUMBING DEMO FIRST FLOOR PLAN — PLUMBING SECOND FLOOR PLAN — PLUMBING rani az I SEPARATE PERMIT AND APPROVAL REQUIRED 90% SUBMITTAL - JULY 20, 2017 King nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SICNBD FSi consulting engineers Seattle, Washington Solutions & Service ISSUE / REVISIONS ID DATE DESCRIPTION CdTYROF rl i TUKw Jo 2617 1134M17. Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title LEGEND, ABBREV., AND NOTES P-000 6/14/2017 9:34:24 AM Sheet Size: 22°x34" (24"x36") PLUV3I\G FIXTURE SCHEDULE MARK FIXTURE DESCRIPTION BRANCH PIPE SIZE — INCHES DIA. ADDITIONAL COMPONENTS BASIS OF DESIGN REMARKS COLD WATER HOT WATER WASTE VENT MANUFACTURER MODEL LAV -1 COUNTERTOP—MOUNTED LAVATORY 1/2" 1/2" 1 1/2" 1 i FAUCET: CHICAGO #2201-4CP W/ POP—UP DRAIN KOHLER #K-2196-4 WC -1 FLOOR—MOUNTED WATER CLOSET (F.V.) 1" — 3" 1 1/2" FLUSH VALVE: CHICAGO #116.620.21.1 SEAT: OLSONITE #95 KOHLER #K-4350 D r Opo 1 SEPARATE PERMIT AND APPROVAL REQUIRED 90% SUBMITTAL - JULY 20, 2017 La nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED FSI consulting engineers Seattle, Washington Solutions & Service ISSUE / REVISIONS ID DATE DESCRIPTION —Ciro �`IVEp JUL 2 8 201? PERMIT CE. TER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title PLUMBING SCHEDULES P-001 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") STAIR DN LUDD I DI 0 n r c MEN ) H ) \A/ [1 EN A C. CT C 0 [R, 1.7 DO Qc. ft IL- 0 D N W PEA A C. (7 L_/\ 1.` 0 -r 713 1 0 ICE r 7 0 F- C KICHIN D C') -3 DN STAIR A- L.... LA3 Si SECOND FLOOR PLAN - PLUMBING DEMO 1/8" = 1'-0" D E IV 0 LITI 0 \ \ OTES: REMOVE AND REUSE SINK br7 cao 1 NORTH 90% SUBMITTAL - JULY 20, 2017 La King County Department of Execbtive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 s design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com N S. . - .0 tx, 1PeOis 0 wAs6,, 49367 4" 41/ ONAL SIGNED 0 FSi consulting engineers Seattle, Washington „ Solutions & Service [MPROVEMEI\J ER PARK W, BLDG NA 98188 ISSUE / REVISIONS ID DATE DESCRIPTION net Cal, °reit/ED TUKWILA Jul. 2 8 2077 Peptii. • "no' CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SECOND FLOOR PLAN - PLUMBING DEMO PD 102 6/14/2017 9:34:24 AM Sheet Size: 220x34" (24"x36") -t- I LOBBY auk r �10 ) ELECT/JANITOR 14 MENS RESTR2 WT1 ;ENDER P: J TRAL 2E STROOM 4521 II C-11 (E)HW (E)CW (E) SINK ' VENT ENTRY CORRIDOR n 1110 WAITING AREA [1as� ADMIN AREA 1075 RESOURCES CCM WOMENS RESTROOM [1U41 MEETING ROOM 10711. N' r__,1 � • =-:� r '> H[Ji FIT (---.) Li COMPUTER ASSESMEh1T LAB 10] El Li r=1 1 r' 1 1L CONFERENCE/ TRAINING 1T7361 1 73(1 tttti l`) �L- 1_. CORRIDOR 1 BEEFING J ROOM [11 C] STORAGE r f M . E.TIN G R.TtOM ['i c MED' RIG . —Rr OM 11 r i L ] f.:.:. v ( I (') IIiCHENif ) COFFEE BREAK ROOM! 'i -1 6 STORAGE WELLNESS X81 MEETING ROOM 11211 IL tL COPY/MAIL/ STORAGE 1125 CONFERENCE i1E1 1-1 Li MEETING ROOM FIRST FLOOR PLAN - PLUMBING 1/8"=11-0" WORK AR [12 4] MEETING ROOM [231 CO\STRUCTIO\ \OYES: CONNECT 1/2" CW TO MAIN IN MECHANICAL ROOM. CONNECT 1 1/2" V TO EXISTING MAINS. CONNECT 3"WTO NEW TOILET CONNECTION IN SLAB BELOW. r�- ([LI OPEN OFFICE 122 ^i STORAGE -- 1214 ,I I— ADMIN ENTRANCE (1 HA // `•'TO RAG E / RESOURCES AN I OPEN OFFICE 1121] 1 LTT (170 E CONNECT 1/2" CW, 1/2" HW AND 1 1/2" V TO MAINS ON THIS FLOOR. CONNECT 1 1/2" W TO NEW SINK CONNECTION IN WALL. bri 0101 NORTH 90% SUBMITTAL JULY 20, 2017 • Department Facilities Management Capital Planning King County 500 4th Avenue, Seattle, WA Tel. 206.477.9367 County of Executive Services Division & Development Administration Bldg. Room 820 98104 design collaborative 119 South Main Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com St, Suite 400 oN S p 45 49387 Q SS/ONAL ENS\•.. SIGNED 0 FSi consulting engineers Seattle, Washington C ' Solutions & Service [MPROVEMEN ER PARK W, BLDG NA 98188 ISSUE / REVISIONS ID DATE DESCRIPTION CITY opE�VED LA J 2 8 2011 __Pennernrr ER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title FIRST FLOOR PLAN - PLUMBING 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") 10 ) F LOBBY 11 1 J ( 1 RESOURCE AND COMPUTERS 12011 a (I MEETING ROOM L202J a w 12" El MEETING ROOM 12041 \ ELECTRICAL MENS RESTROOM WOMENS RESTROOM • KCIT CLOSET L.HW (Li CLASSROOM A (1._ El 7 ) (6-) ( 5 ) -1r --------- 11/ -------- ----- _ffr r RECEPTION! WAITING AREA L2.0A CORRIDOR 1:29pi a MEETING ROOM (i MEETING ROOM 12071 I WELLNESS! LACTATION 1 ON )271 ,..„S> SAN— SINK VENT CLASSROOM B 19081 (10 FE ALIGN LII I (11 ((i CL I Cli H - CLASSROOM Cl LJ(21 ClCli CLASSROOM C2 1211I k Cl UI El _ Li Li !4) MEETING ROOM ,-• MEETING ROOM --122$1 Li ( L. RTC INSTRUCTOR OFFICE OPEN OFFICE 12191 A El fil TESTING AREA 12121 SECOND FLOOR PLAN — PLUMBING 1/8"=11-0" COORIDOOR 1.2_IA 7- / Lii BREAK ROOM 12141 (El LT' Eli MEETING ROOM MEETING ROOM 421J • MEETING ROOM SECURED FILE \ STORAGE 12171 ' L MEl I MEETING' 1-1 ROOM _a Li Lid r Li ILI _X RI //1 MEETING ROOM 12181 /AzA/T/d///,_/ Eli Eli SECURE OPEN OFFICE 12181 El E) CONS—RUCTIO\ \OTES: CONNECT 1/2" CW AND 1/2" HW TO EXISTING. CONNECT 1 1/2" V AND 3" W TO TO EXISTING. REUSE AND RELOCATE EXISTING SINK. 1)(7 0.201 90% SUBMITTAL — JULY 20, 2017 • • •Cowity Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 0 design collaborative 119 South Main St Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com ,$)() S. T pIIF I ..c., 0' Arz:" 61,‘ 17 ,Y110' 3, r,.., 4,49367 €4, y 4-0IST sioNAL E°\ SIGNED - 0 FSI consulting engineers Seattle, Washington , ) Solutions & Service [MPROVEMEN ER PARK W, BLDG NA 98188 ISSUE / REVISIONS ID DATE DESCRIPTION C %Erg D , ut,VEa... vvILA JUL 2 8 2017 PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SECOND FLOOR PLAN — PLUMBING P102 GENERAL LEGEND NORTH ARROW DETAIL, DRAWING REFERENCE SECTION REFERENCE CONSTRUCTION NOTE BOLD LINE WEIGHT INDICATES NEW WORK LIGHT LINE WEIGHT INDICATES EXISTING SLASHED LINE INDICATES EXISTING WORK TO BE DEMOLISHED OR ABANDONED AS INDICATED ON PLANS FIRE SUPPRESSION LEGEND -0-o- 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") OS & Y VALVE VALVE IN RISER PLUG, CAP OR BLIND FLANGE PIPING IDENTIFIER, SEE ABBREVIATIONS PIPING REDUCER FIRE DEPARTMENT CONNECTION FLOW SWITCH SPRINKLER HEADS ABV AD ADDN AFF ALT AP APPROX ARCH AUX BAL BLDG BSMT BTU BTU H CAP CL CLG CMU COND COL CONC CONN CONST CONT CONTR COORD D DEG DIA DIAG DIFF DIM DISCH DIV DN DP DR DWG EA EFF ELEC ELEV EMCS ENT EQ EQUIP ET EWT EX, (E) EXP EXPL F FIO FIN FLEX FLR FOIC FP FT GA GAL GC GEN GPM GWB H HOA HOR HP HR HZ IBC ID IFC IMC IN INFO INSUL KW KWH L LAB LAV LB GENERAL ABBREVIATIONS ABOVE ACCESS DOOR ADDITION, ADDITIONAL ABOVE FINISHED FLOOR ALTERNATE ACCESS PANEL APPROXIMATELY ARCHITECT; ARCHITECTURAL AUXILIARY BALANCING BUILDING BASEMENT BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CENTERLINE CEILING CONCRETE MASONRY UNIT CONDENSATE COLUMN CONCRETE CONNECT; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION CONTRACTOR COORDINATE DEEP (DIM) DEGREE DIAMETER DIAGONAL; DIAGRAM DIFFERENTIAL DIMENSION DISCHARGE DIVISION DOWN DIFFERENTIAL PRESSURE DRAIN DRAWING EAC H EFFICIENCY ELECTRICAL ELEVATION; ELEVATOR ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUAL EQUIPMENT EXPANSION TANK ENTERING WATER TEMPERATURE EXISTING EXPOSED EXPLOSION FAHRENHEIT FURNISHED 8c INSTALLED BY OWNER FINISHED FLEXIBLE FLOOR FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FIRE PROTECTION; FREEZE PROTECTION FEET; FOOT; FEET OF WATER(PRESS) GAGE; GAUGE GALLON GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GYPSUM WALLBOARD HEIGHT; HIGH HAND OFF AUTOMATIC HORIZONTAL HORSE POWER HOUR HERTZ NTERNATIONAL BUILDING CODE NSIDE DIAMETER NTERNATIONAL FIRE CODE NTERNATIONAL MECHANICAL CODE NCH NFORMATION NSULATE; INSULATION KILOWATT KILOWATT HOUR LENGTH; LONG (DIM) LABORATORY LAVATORY POUND LBS/HR LF LO LTG LVG LWT MAT MAX MBH MCC MECH MED MFG MFR MIN MISC MTD MTG MTL N NA NC NIC NO NOM NTS OC OD OPP PD PERF PERP PH POC PRELIM PRESS PROP PS PSI PSIG PT QTY R RAD REF REFR REQD RET RM RPM S SCHED SECT SF SHT SIM SOL SPEC SPECD SQ STD STRUCT TBD TD TEMP TH THRU TYP UBC UL UTIL V VAR VEL VERT VOL W W/ W/O WT YD YR POUNDS PER HOUR LINEAL FEET LOW LIGHTING LEAVING LEAVING WATER TEMPERATURE MATERIAL MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MOTOR CONTROL CENTER MECHANICAL; MECHANICAL CONTRACTOR MEDIUM MANUFACTURING MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOUNTED MOUNTING METAL NORTH NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER; OVERALL DIMENSION OPPOSITE PRESSURE DROP PERFORATED PERPENDICULAR PHASE POINT OF CONNECTION PRELIMINARY PRESSURE PROPERTY; PROPOSAL PRESSURE SWITCH POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE PRESSURE/TEMPERATURE TAP QUANTITY RADIUS; RETURN; RISER RADIATOR REFERENCE REFRIGERATION REQUIRED RETURN ROOM REVOLUTIONS PER MINUTE SOUTH SCHEDULE SECTION SQUARE FEET SHEET SIMILAR SOLENOID SPECIFICATION SPECIFIED SQUARE STANDARD STRUCTURAL TO BE DETERMINED TEMPERATURE DIFFERENTIAL TEMPERATURE TOTAL HEAD THROUGH TYPICAL UNIFORM BUILDING CODE UNDERWRITER'S LABORATORY UTILITY VOLT VARIABLE VELOCITY VERTICAL VOLUME WATER; WIDE(DIM); WATT WITH WITHOUT WEIGHT YARD YEAR FIRE PROTECTION ABBREVIATIONS AS FH NFPA OSY SPR UFC AUTOMATIC SPRINKLER FIRE HOSE; FIRE HYDRANT NATIONAL FIRE PROTECTION ASSOCIATION OUTSIDE SCREW AND YOKE SPRINKLER UNIFORM FIRE CODE FIRE PROTECTION DRAWING INDEX FP -000 FP -101 FP -102 LEGEND, ABBREVIATIONS AND NOTES FIRST FLOOR PLAN — FIRE PROTECTION SECOND FLOOR PLAN — FIRE PROTECTION bC7o2oI SEPARATE APp MIT AND REQUIRED 90% SUBMITTAL - JULY 20, 2017 King nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED • FSi consulting engineers Seattle, Washington Solutions & Service I-' • ..z 6 W W 0 U E m cX w O O oo ,_, U) Ct< 01 T a. a. Q �� ws � O�� O U z o1 ,Q Z - T T Z < H U Liudam' 0� 'oI- ISSUE / REVISIONS ID DATE DESCRIPTION C/TyRafi ElukwiLA VED JUL 28 2017 CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title LEGEND, ABBREV., AND NOTES FP -000 T ::-ECT/JANrrc,R r rf Jl i__-._.. C; I! WOMEN 'S RESTROOM NTE'r dDR C.:OMF'UT ER ENT 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") FIRST FLOOR PLAN - FIRE PROTECTION 1/8" = 1'-0" C3 \STUCTIO\ OTES: tL+ RELOCATE SPRINKLER HEADS AS NECESSARY TO MAINTAIN FIRE PROTECTION COVERAGE. L'7O.?O1 90% SUBMITTAL - JULY 20, 2017 La nty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com SIGNED • FSi consulting engineers Seattle, Washington Solutions & Service .. z C� W LU 0 U m W OO c cn ce %oo Zea. a.Q O O�� O U z p < z zu LU Q� 5C H 1 -- ISSUE / REVISIONS ID DATE DESCRIPTION CITYpfi VED r�Kw��a JUL 2 8 2017 PERER TSR Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title FIRST FLOOR PLAN - FIRE PROTECTION FP -101 _...3TFO :4 CORF:i_% 6/14/2017 9:34:24 AM Sheet Size: 22"x34" (24"x36") ROOt,:M, SECOND FLOOR PLAN - FIRE PROTECTION 1/8" =1'-0" CO\STUCTIO\ \OYES: RELOCATE SPRINKLER HEADS AS NECESSARY TO MAINTAIN FIRE PROTECTION COVERAGE. D �7 O1O( NORTH 90% SUBMITTAL - JULY 20, 2017 Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com Pr... M1 +'ikpa'a 31tluL ' �h k SIGNED FSi consulting engineers Seattle, Washington Solutions & Service cn W W � W oa � O O�� U z Q zUw YAH ISSUE / REVISIONS ID DATE DESCRIPTION CITYRE 4 CeiveD WIL p JUL2-8-2U1v___ PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: MJV/GMN Checked By: BSC Sheet Title SECONDFLOOR PLAN - FIRE PROTECTION FP -102 4 4 4ii II 7/27/2017 11:54 AM CIRCUITING SYMBOLS HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION JUNCTION BOX, CEILING/WALL POWER ER SY BOLS DUPLEX RECEPTACLE 120V DUPLEX "CONTROLLED" RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V DOUBLE DUPLEX "CONTROLLED" RECEPTACLE 120V MODULAR FURNITURE DUPLEX RECEPTACLE MODULAR FURNITURE "CONTROLLED" DUPLEX RECEPTACLE DUPLEX / QUAD RECEPTACLE — GENERATOR POWER DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFCI DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE DISCONNECT SWITCH FUSED DISCONNECT MOTOR CONNECTION EQUIPMENT CONNECTION MOTOR RATED SWITCH ELECTRICAL PANEL LIGHTING PANEL SYMBOLS & ABBREVIATIONS SIGNAL & COMMUNICATION SYMBOLS El MAGNETIC DOOR HOLD—OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. O FIRE ALARM MANUAL STATION +48" D I� O D R ID TAG SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK—UP COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. COMBINATION HORN/STROBE, CEILING MOUNTED FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" FIRE ALARM STROBE ONLY, CEILING MOUNTED FIRE ALARM REMOTE INDICATOR LIGHT FIRE ALARM BELL/CHIME TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" DATA OUTLET COMBINATION TELE/DATA OUTLET SINGLE OR DOUBLE GANG BOX, RACEWAY TO ACCESSIBLE CEILING SPACE WITH BLANK COVER PLATE. MISCELLANEOUS FLAG NOTE REVISION SYMBOL EQUIPMENT IDENTIFIER XX O V LIGHTING SYMBOLS 1X4 FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE CEILING MOUNTED DOWNLIGHT 4' LINEAR PENDANT LIGHT FIXTURE RADIANT HEAT PANEL BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN — ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH DIMMER/SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION WALL MOUNT OCCUPANCY SENSOR CEILING MOUNT OCCUPANCY SENSOR CEILING OCCUPANCY SENSOR Pc PHOTO—CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH RISER SYMBOLS CIRCUIT BREAKER FEEDER DESIGNATION —ems— FUSED SWITCH i GROUND PANEL TRANSFORMER PAIL II AVAILABLE SHORT CIRCUIT CURRENT METER ABBREVIATIONS AFF ABOVE FINISHED FLOOR A, AMP AMPERE CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED EXST, EXSTG, (E) EXISTING FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR Fl FILM ILLUMINATOR G, GND GROUND GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER IH INSTA HOT J—BOX JUNCTION BOX LTG LIGHTING PNL PANEL PROVIDE FURNISH AND INSTALL REC, RECEPT RECEPTACLE TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE ✓ VOLT W WIRE OR WATT PHASE W/0 WITHOUT WP WEATHERPROOF ri 0,24 SHEET LIST Sheet Number Sheet Title E0.1 SYMBOL LEGEND, ABBREVIATIONS, SHEET LIST E0.2 FIXTURE SCHEDULE, NREC FORMS ED1.1 FIRST FLOOR POWER AND SIGNAL DEMO PLAN ED1.2 FIRST FLOOR LIGHTING DEMO PLAN ED1.3 SECOND FLOOR POWER DEMO PLAN ED1.4 SECOND FLOOR LIGHTING DEMO PLAN E2.1 FIRST FLOOR POWER AND SIGNAL PLAN E2.2 SECOND FLOOR POWER AND SIGNAL PLAN E3.1 FIRST FLOOR LIGHTING PLAN E3.2 SECOND FLOOR LIGHTING PLAN E5.1 PARTIAL RISER DIAGRAM E6.1 PANEL SCHEDULES E6.2 PANEL SCHEDULES (2) E6.3 PANEL SCHEDULES (3) SEPARATE rCR1v,1fAN APPROVAL REQUIRED PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3n1 Avenue S., Suite 2C tet: (206)223-6446 Seattle, Washington 98104 fax: (206)2236465 EXPIRES 1-17-18 N ww Uw 00 Opp U z Q z U w 0 I- 0 0 J co cc co LU > o � 0 J zI Q 5 Ln� ko ISSUE / REVISIONS F ci�Yne /1/E0 TvkW/LA JUL 28 2017 PERM1r cEN7-ER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SYMBOL LEGEND, ABBREVIATIONS, SHEET LIST E0.1 LIGHTING FIXTURE SCHEDULE Date 7/27/2017 CalculationAddition- Area NOTE 9 Watts/ Fixture NOTE7 LAMP AdditionFor • New Construction � � • Clear stand alone +existing (C505) TYPE MANUFACTURER SERIES NO. (CATALOG NO.) VOLT NO. TYPE BALLAST FIXTURE WATTS DESCRIPTION INTERIOR LIGHTING Maximum Allowed Lighting Wattage NOTE 1 18 Location (plan #, room #) Space Type Ceiling HeightNOTE2 Gross Interior Area in ft2 El EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2X4' FIXTURE TO REMAIN IN PLACE WITH NO MODIFICATIONS. E1E EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2'X4' FIXTURE PROVIDED WITH EMERGENCY BATTERY PACK TO REMAIN IN PLACE WITH NO MODIFICATIONS. E2 EXISTING - 277 1 18W TRT - 18 EXISTING RECESS MOUNT DOWNLIGHT FIXTURE TO REMAIN IN PLACE WITH NO MODIFICATIONS. E3 EXISTING - 277 1 F32T8 - 32 EXISTING RECESS MOUNT 2'X4' FIXTURE TO BE REMOVED OR RELOCATED. L1 TECH LIGHITNG MINI ECHO PENDANT 12V VIA 120/277 1 LED INTERNAL DRIVER 8 TRANSLUSCENT CYLINDER PENDANT FIXTURE. LOW VOLTAGE MAGNETIC TRANSFORMER REQUIRED. CONFIRM COLOR TEMPERTURE, FIXTURE FINISH AND MOUNTING TYPE WITH ARCHITECT. L2 PHILIPS LIGHTOLIER CALCULITE LED 3 277 1 LED INTERNAL DRIVER 11 1000 LUMEN RECESS MOUNT LED DOWNLIGHT. CONFIRM FIXTURE COLOR TEMPERTURE, FINISH, DISTRIBUTION AND LENSING WITH ARCHITECT. FIXTURE TO BE PROVIDED WITH 0-10V DIMMING. L3 TBD 6 277 1 LED INTERNAL DRIVER 50 TDB L4 APOLLO LED SERIES 120V N/A LED INTERNAL DRIVER 18 WALL MOUNT LED VANITY FIXTURE. SATIN NICKEL HOUSING, WHITE ACRYLIC DIFFUSER, COLOR TEMPERATURE = 3000K, NOMINAL LENGTH = 28" R1 EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2'X4' FIXTURE TO BE REMOVED OR RELOCATED. R1E EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2'X4' FIXTURE PROVIDED WITH EMERGENCY BATTERY PACK TO BE REMOVED OR RELOCATED. R2 EXISTING 277 1 18W TRT - 18 EXISTING RECESS MOUNT DOWNLIGHT FIXTURE TO REMAIN IN PLACE WITH NO MODIFICATIONS. R3 EXISTING - 277 1 F32T8 - 32 EXISTING RECESS MOUNT 2'X4' FIXTURE TO BE REMOVED OR RELOCATED. R4 EXISTING - 277 1 F32T8 - 32 36 CFL MONOPOINT PENDANT FIXTURE TO BE REMOVED OR RELOCATED T1 E EXISTING - 120 1 - 50 EXISTING RECESS TRACK LIGHTING TO REMAIN IN PLACE WITH NO MODIFICATIONS. T1R EXISTING - 120 1 - 50 EXISTING RECESS TRACK LIGHTING TO BE REMOVED OR RELOCATED. X1 MATCH EXISTING - 277 1 LED - 3 3W EXIT SIGN. MATCH BUILDING STANDARD. CONFIRM TYPE WITH ARCHITECT IF BUILDING STANDARD IS UNAVAILABLE. X1E EXISTING - 277 1 LED - 3 EXISTING 3W EXIT SIGN X2E EXISTING - 277 1 LED - 6 EXISTING 7W LED DUAL HEAD EMERGENCY FIXTURE X1R EXISTING - 277 1 LED - 3 EXISTING 3W EXIT SIGN TO BE REMOVED OR RELOCATED .� u' Interior atg ting SP i ay Spalce IVIethad LTG INTI SPACE 2131.5 aer,nolions,.,. En.,o.Code C .,.n<.:>,m.for Comm .,.,.leu,a,no.Including, er PS ea July...Ulla Project Title: fling County- DCHS WorkSource Date 7/27/2017 CalculationAddition- Area NOTE 9 Watts/ Fixture NOTE7 Building Department Use AdditionFor • New Construction � � • Clear stand alone +existing (C505) el Spaces where <50% of is Spaces where Z50%of • Spaces wheretheUse luminaires are replaced luminaires are replaced is changing LPA Calculation Type Option Power than the Target 21 0 Standard . Additional Efficiency Package • Clear C406.3 Reduced InteriorLighting To comply with C406.3, the Proposed LPD shall be 25% lower Refer to C406.3 for additional requirements. LPA. Maximum Allowed Lighting Wattage NOTE 1 18 Location (plan #, room #) Space Type Ceiling HeightNOTE2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (w atts/ft2 x area) L1 SUSPENDED PENDANT - 8W LED 5 8 40 L2 RECESSED DOWNLIGHT - 11W LED 17 11 187 L4 18W LED DECORATIVE VANITY 1 18 18 R1 RECESSED 2'x4' - 2L F32T8 45 64 2880 RIE RECESSED 2k4' - 2L F32T8 4 64 256 R2 RECESSED DOWNLIGHT - 18W TRT 3 18 54 T1 E TRACK LIGHTING - 50W PER LINEAR FT 48 50 2400 Enter Lobby Art/Exhibit Display Allow ance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display Total Existing 3 LTG -INT -DISPLAY (prior to Alteration) Allowed Watts Allow ance from Lighting Watts 13 23258 39 23258 Proposed Lighting Wattage NOTE 3 Location (plan #, room #) Fixture Description NOTE n's' 6 Number of Fixtures Watts/ Fixture NOTE7 Watts Proposed El RECESSED 2'x4' - 2L F32T8 150 64 9600 E1 E RECESSED 2'x4' - 2L F32T8 21 64 1344 E2 RECESSED DOWNLIGHT - 18W TRT 13 18 234 E3 RECESSED LINEAR WALL WASH - 1L F32T8 16 32 512 L1 SUSPENDED PENDANT - 8W LED 5 8 40 L2 RECESSED DOWNLIGHT - 11W LED 17 11 187 L4 18W LED DECORATIVE VANITY 1 18 18 R1 RECESSED 2'x4' - 2L F32T8 45 64 2880 RIE RECESSED 2k4' - 2L F32T8 4 64 256 R2 RECESSED DOWNLIGHT - 18W TRT 3 18 54 T1 E TRACK LIGHTING - 50W PER LINEAR FT 48 50 2400 X1 3W LED EXIT SIGN 4 3 12 X1 E 3W LED EXIT SIGN 13 3 39 X2E 3W LED DUAL HEAD EMERGENCY FIXTURE 2 6 12 X1 R 3W LED EXIT SIGN 2 3 6 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 17594 Interior Lighting Power Allowance COMPLIES Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2- Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3- List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5- For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. identify as existing in fixture description. Note 7- For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8- Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided in flu? Maximum Allnwarll inhtinn IA/attanP tahla bc7 ER RATE APPROIT VAND REQUIRED PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (208)223-6446 Seattle, Washington 98104 fax: (208)223-6465 EXPIRES I—17-18 l0 rn. a J m CO 00 I.Lco a. • °1 w o � 0 z f-1 Q5 Ln H ISSUE / REVISIONS [';) DESCRIPTION CITYt!� WED p TUKWILA JUL 2 8 2017 PER ITcEN TER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIXTURE SCHEDULE, NREC FORMS E0.2 //2//201/ 11:54 AM DOHS WORKSOURCE (WJA)\CADD\1 /0.30 - ED101.DWG GENERAL NOTES: 1. SOLID UNE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDI11ONS ARE KNOWN NOR ARE ALL FIELD CONDI11ONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. UNLESS NOTED OTHERWISE, ALL INDICATED DEVICES, EQUIPMENT AND ASSOCIATED INFRASTRUCTURE/RACEWAY/CONDUCTOR SHOWN HATCHED ARE TO BE REMOVED BACK TO SOURCE OR NEXT INLINE DEVICE WHERE CONTINUITY IS TO BE MAINTAINED. DEVICES NOT HATCHED ARE INTENDED TO STAY AS EXISTING AND EITHER MAINTAINED OR RECONNECTED (SEE POWER PLANS). DISCONNECT AND LEAVE CONNECTED EXISTING DEVICE WIRING IN ACCESSIBLE CEILING SPACE FOR FUTURE CONNECTION. WHERE CIRCUITS ARE INDICATED THEY ARE TAKEN FROM RECORD DRAWING INFORMATION AND ARE INTENDED TO BE PULLED BACK TO ACCESSIBLE SPACE TO BE EXTENDED TO MAINTAINED AND/OR NEW DEVICE/LIGHTING/EQUIPMENT LOCATIONS. MAINTAIN CONTINUITY TO ALL REMAINING DEVICES AS REQUIRED. SEE POWER PLAN FOR DETAILS. 5. FIRE ALARM: UNLESS NOTED OTHERWISE EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES TO BE MAINTAINED AND RE—PURPOSED. ALL EXIST DEVICES IN IMMEDIATE TENANT REMODEL SPACE TO BE CLEANED AND COVERED WITH PROTECTIVE PLASTIC. NEW FIRE ALARM DEVICES WHERE REQUIRED ARE TO BE INTEGRATED INTO THE EXISTING DEVICE LOOPS. WHERE DEVICES ARE RELOCATED CONTRACTOR TO MAINTAIN CIRCUIT CONTINUITY AS REQUIRED. 6. MECHANICAL: ALL VAV BOXES AND FEEDER TRUNK LINES TO BE MAINTAINED UNDER DEMOLITION FOR REMOVAL/RELOCATION UNDER TENANT IMPROVEMENT BUILD OUT. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND PROVIDE RECORD DRAWING INDICATING EXISTING BOX 0 0 LOCATIONS, NAMEPLATE INFORMATION INCLUDING VOLTAGE, HEATER/FAN SIZE (RATINGS) AND CONNECTED FEEDER TRUNK LINE CIRCUITS INFO FOR FUTURE RELOCATION/REPURPOSING. 7. SECURITY/ACCESS CONTROL: UNLESS NOTED OTHERWISE INDICATED EXISTING DEVICES TO BE REMOVED AND RE—PURPOSED. REMOVE ASSOCIATED CABLING/RACEWAY/INFRASTRUCTURE BACK TO SOURCE (IT/TELECOM ROOM). 8. INDICATED EXISTING FLOOR BOX/POKE THRU DEVICES TO BE REMOVED AND FIRE SEALED. CONTRACTOR TO VERIFY FINAL QUANTITY ON SITE. REMOVE ALL ASSOCIATED CABLING/INFRASTRUCTURE BACK TO SOURCE OR MAINTAIN CONTINUITY TO NEXT INLINE DEVICE. FLAG NOTES: FIRE ALARM DEVICE TO BE RELOCATED. SEE SHEET E2.1 FOR NEW LOCATION. PANEL PA2 U.O.N PANEL PA1 U.O.N PANEL PA1 PANEL PA2 U.N.O U.N.O FIRST FLOOR POWER AND SIGNAL DEMO PLAN SCALE: 1/8" = 1'-0" O 0 NORTH PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S. Suite 2C lel: (206)2236446 Seattle, Washington 98104 fax: (206)223-6465 EXPIRES 1-17-18 TENANT IMPROVEMENTS ISSUE / REVISIONS �i�-�,ne IVED ilk 2 8 2017 NitR Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR POWER AND SIGNAL DEMO PLAN ED1.1 GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED UNE WORK INDICATES EXISTING TO BE DEMOLISHED OR RELOCATED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES MAY REQUIRE BEING RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH AN NEW OR EXISTING PHOTOCELL AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 5. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAYS AS INDICATED/REQUIRED IN NEW E3 SERIES LIGHTING PLANS. 6. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: EXISTING SWITCH(S) TO BE RELOCATED. SEE SHEET E3.1 FOR NEW LOCATION. EXISTING OCCUPANCY SENSOR TO BE RELOCATED. SEE SHEET E3.1 FOR NEW LOCATION. EXISTING EXIT SIGN TO BE RELOCATED. SEE SHEET E3.1 FOR NEW LOCATION. &4.7::R2 I1 P IIII II II 0R21 1.11 IIII X®*R21III Ig II FIRST FLOOR LIGHT SCALE: 1/8" = 1'-0" NG DEMO PLAN 0.10( NORTH PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.6446 Seattle, Washington 98104 tax: (206)223.6465 EXPIRES I-17-18 (f) q) .. z 6 W LTJ 0 U o cC LTJ O O ,° 9( 01 W O0 H. > u z g� Cn Q z z=z Q� � U w Ln 0 1-- �E- ISSUE / REVISIONS CITY Ro IVED F: TUKWILA JUL 28 2017 PE! M!r CENTER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR LIGHTING DEMO PLAN ED1.2 GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOUIION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOUIION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. UNLESS NOTED OTHERWISE, ALL INDICATED DEVICES, EQUIPMENT AND ASSOCIATED INFRASTRUCTURE/RACEWAY/CONDUCTOR SHOWN HATCHED ARE TO BE REMOVED BACK TO SOURCE OR NEXT INLINE DEVICE WHERE CONTINUITY IS TO BE MAINTAINED. DEVICES NOT HATCHED ARE INTENDED TO STAY AS EXISTING AND EITHER MAINTAINED OR RECONNECTED (SEE F1)103.DWG //2//201/ 11:bb AM i POWER PLANS). DISCONNECT AND LEAVE CONNECTED EXISTING DEVICE WIRING IN ACCESSIBLE CEILING SPACE FOR FUTURE CONNECTION. WHERE CIRCUITS ARE INDICATED THEY ARE TAKEN FROM RECORD DRAWING INFORMATION AND ARE INTENDED TO BE PULLED BACK TO ACCESSIBLE SPACE TO BE EXTENDED TO MAINTAINED AND/OR NEW DEVICE/LIGHTING/EQUIPMENT LOCATIONS. MAINTAIN CONTINUITY TO ALL REMAINING DEVICES AS REQUIRED. SEE POWER PLAN FOR DETAILS. 5. FIRE ALARM: UNLESS NOTED OTHERWISE EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES TO BE MAINTAINED AND RE—PURPOSED. ALL EXIST DEVICES IN IMMEDIATE TENANT REMODEL SPACE TO BE CLEANED AND COVERED WITH PROTECTIVE PLASTIC. NEW ARE ALARM DEVICES WHERE REQUIRED ARE TO BE INTEGRATED INTO THE EXISTING DEVICE LOOPS. WHERE DEVICES ARE RELOCATED CONTRACTOR TO MAINTAIN CIRCUIT CONTINUITY AS REQUIRED. 6. MECHANICAL: ALL VAV BOXES AND FEEDER TRUNK LINES TO BE MAINTAINED UNDER DEMOU11ON FOR REMOVAL/RELOCATION UNDER TENANT IMPROVEMENT BUILD OUT. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND PROVIDE RECORD DRAWING INDICATING EXISTING BOX 9 • LOCATIONS, NAMEPLATE INFORMATION INCLUDING VOLTAGE, 'HEATER/FAN SIZE (RATINGS) AND CONNECTED FEEDER TRUNK LINE CIRCUITS INFO FOR FUTURE RELOCATION/REPURPOSING. 7. SECURITY/ACCESS CONTROL UNLESS NOTED OTHERWISE INDICATED EXISTING DEVICES TO BE REMOVED AND RE—PURPOSED. REMOVE ASSOCIATED CABLING/RACEWAY/INFRASTRUCTURE BACK TO SOURCE (IT/TELECOM ROOM). 8. INDICATED EXISTING FLOOR BOX/POKE THRU DEVICES TO BE REMOVED AND ARE SEALED. CONTRACTOR TO VERIFY FINAL QUANTITY ON SITE. REMOVE ALL ASSOCIATED CABLING/INFRASTRUCTURE BACK TO SOURCE OR MAINTAIN CONTINUITY TO NEXT INLINE DEVICE. FLAG NOTES: FIRE ALARM DEVICE TO BE RELOCATED. SEE SHEET E2.2 FOR NEW LOCATION. PB1/19 PB1 /4 PB1 /19 0 111113131/12 PB1/12 r PB2/20,22,24E P82/26,28,30 PB2/25 i PB2/27 P82/19 C O_J PB2/21 62/19 0PB1 /12 PB2/27 —� PB2/29 PB2/27 PB1/8 t1 P81/8 DN PB1/6 PB1/12 - PB2/2 PB2/2 z'c®� PB2/23 PB1/2 OPB1 /12 ID PB2/6,8,10 C V 36" B B 36" FURNITURE COIL - PB1/24,26,28 it r, 111.-1 PB22134 PB3/9 yB3/9 PB3/9r, PB1/10� PB3/9 I-1 —1— EFJ PB2/4 i I PB2/4 �x�rp-1 P62/230 PB2/1 PB2 __I/382/10 PB 3 PB3/3 PB3/3 PB2/5 P81/5 PB1/3,5 1 PB1/5 -P, P83 1/311.333,35 60 PB1/377,,39,4 F PB3/5 .4`, TDA F PB3/5 QUO r PB3/5 PB3/2 Jul a OP63/5 PB3/7 PB3/21 PB2/3O PB2/16 PB3/30 PB2/9 U .PB2/14 P62/16 P62/16 PB2/90 PB1/11 36"PB1 n F3-41%./ PB3/50 36" PB1/20 PB3/8 e- PB1 /22 �PB1 /22 PB1/24,26 z PB1/1 PB3/8 0 PB3/7 PB1/20 E P81/1 PB1/1 PB1/15 PB2/18 PB2/18 B PB3/6 PB3/6 PB3/6 no u F PB3/4 I B3/4 PB3/4y- P83/6 PB1/19 EDI PB1/19 P81/19 FtiP82/15 P82/13 P52/17 PB2/9 ;h PB2/90 SECOND FLOOR POWER DEMO PLAN SCALE: 1/8" = 1'-0" SCALE: 1/8" = (7,) az° SEP E 8' 16' REQ NORTH PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel; (206)223-6448 Seattle, Washington 98104 fax: (206)223-6465 EXPIRES I-17-18 <O ..z (9 w Ili a U E m Ce W • O O ,° Cn DC % 01 Z a. f1 Q O > g ..1 (in-, � z U w Ln SOH 'oH ISSUE / REVISIONS JUL.CITY' OP ruKwit4 28 2017 Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR POWER DEMO PLAN ED1.3 1/21/2011 11:55 AM GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED OR RELOCATED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES MAY REQUIRE BEING RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH AN NEW OR EXISTING PHOTOCELL AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 5. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAYS AS INDICATED/REQUIRED IN NEW E3 SERIES LIGHTING PLANS. 6. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: EXISTING SWITCH(S) TO BE RELOCATED. SEE SHEET E3.2 FOR NEW LOCATION. EXISTING OCCUPANCY SENSOR TO BE RELOCATED. SEE SHEET E3.2 FOR NEW LOCATION. TT 3--V SECOND FLOOR LIGHTING DEMO PLAN SCALE: 1/8" = 1'-0" br azo 1 PERMIT SET - JULY 21, 2017 Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C teL (206 23-6446 Seattle, Washington 98104 fax: (2061223.6465 EXPIRES I-17-18 TENANT IMPROVEMENTS rlfl 0 —JCC) co C0 Ce 00 a `W O� OJ Z - Q5 ISSUE / REVISIONS CITyne........... c FI vEO TUKWILA JUL 28 2017 N7E Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR LIGHTING DEMO PLAN ED1.4 7/27/2017 11:55 AM PANEL PA2 U.O.N LODE: 1)1! ADA DOOR ACTUATOR PANEL PA1 U.O.N AL1 7! WAITING TIfNG AREA ENTRY CORRIDOR GENERAL NOTES: 1. DASHED LINE WORK INDICATES EXISTING TO REMAIN. 2. CONTROLLED RECEPTACLES (SHADED — SEE SYMBOL LEGEND): UNLESS NOTED OTHERWISE, PROVIDE 20A AUXIUARY RELAY POWER PACK TIED TO LIGHTING CONTROL SENSOR IN AREA SERVED FOR OPERATION OF CONTROLLED RECEPTACLES. 3. ELECTRICAL CONTRACTOR TO PROVIDE POWER/DATA RACEWAYS AND POWER FEEDS TO MODULAR FURNITURE CONNECTION POINT. FINAL TERMINATION OF POWER AND DATA BY OTHERS. 4. FIRE ALARM DESIGN IS BIDDER DESIGN. SEE SPECIFICATIONS FOR DETAILS. EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES SHOWN FOR CLARITY ONLY. FIRE ELECT/JANFrOR I WOMEN., RESTROOM 0 0 ENS r L rr :. TELECOM PA2/36,38,40 6 ► AC 1r ER Ni !`I. R. , 1,00 0 i3:'; EF -1 PA2/30 0 0 0 7,11 ��. -111111111 00 ALARM CONTRACTOR TO RELOCATE/REUSE EXISTING DEVICES AS REQUIRED, MODIFYING THE LAYOUT AND LOCATION OF DEVICES AS REQUIRED FOR NEW CONSTRUCTION AND CODE COMPUANCE. 5. INDICATED HOME RUN CIRCUITS HAVE BEEN IDENTIFIED FROM SERVING EXISTING PANEL SCHEDULES AND ASSUMES THAT HOMERUNS WERE LEFT IN ACCESSIBLE CEILING SPACE. EVERY EFFORT HAS BEEN TAKEN TO RE—PURPOSE EXISTING CIRCUITS IN SAME GENERAL VICINITY AS NOTED ON RECORD DOCUMENTS, HOWEVER CONTRACTOR UNDERSTANDS AND SHALL PRICE ACCORDINGLY THAT CIRCUIT HOMERUNS TO SERVING PANELS MAY BE REQUIRED WHERE EXISTING CIRCUITS DO NOT EXIST. Y FLAG NOTES: PROVIDE A/C GRADE, FIRE RATED, 3/4" PRIMED AND PAINTED PLYWOOD. FIRE RATING STAMP SHALL BE VISIBLE FOR INSPECTION BY AHJ. PROVIDE MINIMUM OF 8'X4' CONFIRM LOCATION AND SIZE OF BACKBOARD WITH KCIT PRIOR TO INSTALLATION. TELECOMMUNICATIONS GROUNDING BUS BAR. CONFIRM SIZE AND LOCATION WITH KCIT. CORE DRILL AND PROVIDE (3) 4" SLEEVES UP TO IDF ROOM ABOVE. CONFIRM LOCATION AND QUANTITY WITH KCIT PRIOR TO CORE DRILLING. PROVIDE 12" CABLE TRAY. CONFIRM SIZE, LENGTH AND LOCATION WITH KIT PRIOR TO INSTALLATION. DISCONNECT EXISTING RECEPTACLE AND REPLACE WITH NEW ABOVE GFCI RECEPTACLE ABOVE SINK EXTEND CONDUCTORS AS NEEDED. EXISTING DEVICE TO BE RELOCATED. MAINTAIN WIRING CONTINUITY AND DEVICE FUNCTIONALITY DURING CONSTRUCTION. PROVIDE CONNECTIONS FOR HOT AND CONTROLLED DEVICES TO SYSTEMS FURNITURE. PROVIDE SEPARATE 1" RACEWAY CONNECTION TO ACCESSIBLE SPACE FOR LOW VOLTAGE CABLING. CONFIRM EXACT LOCATION PRIOR TO ROUGH—IN. CONFIRM EQUIPMENT TYPE AND POWER REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH—IN. T 1 r.:EET,NGG ROOM FITCi Ii_ht COFEEE BREAK 0000 COPY/MAIL/ STORAGE OPEN OFFICE t M1 E<u/GE.1 TRAINILICI ,417 41, iryi L0000 Li I__I ': 19 MEETING, 1 ROOM WORK AR CORE DOE r LFI \��19 �1 10 POWER AND DATA POLE PA2/8,10 PA2/23,25 =CF PA2/16,18 6> r!- PA1 /35,37 moo00 3 ®© wL 37 37 37 I 37 o o [1D t 25 25 3 , 2• 3 25 23 10 o DI 27 14 014 C PEN OFFICE AMAIN AREA RESOURCES COMPUTER ASSElil9ENT LAB F3 PA1 /39,41 MEET NG ROC 0 MEETS �LJL�ooi'' P'41 STOP SAGE/ of RCE AO MI/I N ENTRANCE N 0 PANEL PA1 PANEL PA2 U.N.O ® U.N.O (FIRST FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" SCALE: 1/8" = 0' 4' 8' 16' STORAGE 10 o PERMIT SET - JULY 21, 2017 King Coin ;ty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Sulte 2C tel: 206))223.8448 Seattle, Washington 98104 fax: (206)223.6465 EXPIRES 1-17-18 F- LU w Uw ?"" oa O� U z Q zUw D1 - ISSUE / REVISIONS 0 CO 00 0121 I.L. I.L. W o� H Z Q am- I— ID il)A D `.: CDI 'I ION c�TyRoc rvso rINw►cA JUL 2 8.117 PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR POWER AND SIGNAL PLAN E2.1 39� 18� ® 116' 1 41 I 4t 0 MEETS �LJL�ooi'' P'41 STOP SAGE/ of RCE AO MI/I N ENTRANCE N 0 PANEL PA1 PANEL PA2 U.N.O ® U.N.O (FIRST FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" SCALE: 1/8" = 0' 4' 8' 16' STORAGE 10 o PERMIT SET - JULY 21, 2017 King Coin ;ty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Sulte 2C tel: 206))223.8448 Seattle, Washington 98104 fax: (206)223.6465 EXPIRES 1-17-18 F- LU w Uw ?"" oa O� U z Q zUw D1 - ISSUE / REVISIONS 0 CO 00 0121 I.L. I.L. W o� H Z Q am- I— ID il)A D `.: CDI 'I ION c�TyRoc rvso rINw►cA JUL 2 8.117 PERMIT CENTER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR POWER AND SIGNAL PLAN E2.1 7/27/2017 11:55 AM GENERAL NOTES: 1. DASHED LINE WORK INDICATES EXISTING TO REMAIN. 2. CONTROLLED RECEPTACLES (SHADED — SEE SYMBOL LEGEND): UNLESS NOTED OTHERWISE, PROVIDE 20A AUXIUARY RELAY POWER PACK TIED TO LIGHTING CONTROL SENSOR IN AREA SERVED FOR OPERATION OF CONTROLLED RECEPTACLES. 3. ELECTRICAL CONTRACTOR TO PROVIDE POWER/DATA RACEWAYS AND POWER FEEDS TO MODULAR FURNITURE CONNECTION POINT. FINAL TERMINATION OF POWER AND DATA BY OTHERS. 4. FIRE ALARM DESIGN IS BIDDER DESIGN. SEE SPECIFICATIONS FOR DETAILS. EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES SHOWN FOR CLARITY ONLY. FIRE ALARM CONTRACTOR TO RELOCATE/REUSE EXISTING DEVICES AS REQUIRED, MODIFYING THE LAYOUT AND LOCATION OF DEVICES AS REQUIRED FOR NEW CONSTRUCTION AND CODE COMPLIANCE. 5. INDICATED HOME RUN CIRCUITS HAVE BEEN IDENTIFIED FROM SERVING EXISTING PANEL SCHEDULES AND ASSUMES THAT HOMERUNS WERE LEFT IN ACCESSIBLE CEIUNG SPACE. EVERY EFFORT HAS BEEN TAKEN TO RE—PURPOSE EXISTING CIRCUITS IN SAME GENERAL VICINITY AS NOTED ON RECORD DOCUMENTS, HOWEVER CONTRACTOR UNDERSTANDS AND SHALL PRICE ACCORDINGLY THAT CIRCUIT HOMERUNS TO SERVING PANELS MAY BE REQUIRED WHERE EXISTING CIRCUITS DO NOT EXIST. ij J PB2/25 ©1� t P- ,JG P62/25 2� FLAG NOTES: PROVIDE A/C GRADE, FIRE RATED, 3/4" PRIMED AND PAINTED PLYWOOD. FIRE RATING STAMP SHALL BE VISIBLE FOR INSPECTION BY AHJ. PROVIDE MINIMUM OF 8'X4' CONFIRM LOCATION AND SIZE OF BACKBOARD WITH KCIT PRIOR TO INSTALLATION. TELECOMMUNICATIONS GROUNDING BUS BAR. CONFIRM SIZE AND LOCATION WITH KCIT. CORE DRILL AND PROVIDE (3) 4" SLEEVES DOWN TO MDF ROOM BELOW. CONFIRM LOCATION AND QUANTITY WITH KCIT PRIOR TO CORE DRILLING. PROVIDE 12" CABLE TRAY. CONFIRM SIZE, LENGTH AND LOCATION WITH KCIT PRIOR TO INSTALLATION. CORE DRILL FOR POKE—THRU FEED TO PROVIDE POWER AND DATA TO FURNITURE. EXISTING DEVICE TO BE RELOCATED. MAINTAIN WIRING CONTINUITY AND DEVICE FUNCTIONALITY DURING CONSTRUCTION. PROVIDE CONNECTIONS FOR HOT AND CONTROLLED DEVICES TO SYSTEMS FURNITURE. PROVIDE SEPARATE 1" RACEWAY CONNECTION TO ACCESSIBLE SPACE FOR LOW VOLTAGE CABLING. CONFIRM EXACT LOCATION PRIOR TO ROUGH—IN. CONFIRM EQUIPMENT TYPE AND POWER REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH—IN. B2/29 PB2/19 MMEETING '.rzOON B2/19 ETI G TT�a PB1/14,16 ` PB2/6,8,1 PB2/20,22,24 \r/OMEN , \ ' NROCNI J a )) 22—. Ir22 24 011 V PB1 /24,26,28 F-1 � C FAX F RECOUPCE AND COMPUTERS PB1/27mEERO ;f SECURED OLE ror,p,ait; PB2/1`j r EETIN tt ROW. PB2/1614P PB1/3,5 CLAS AN SU q PB3/5 (11) P1B3)(7 27_27 LAI (C P81/20 PPB1 /1 l",'ECE>TION/ WAITING AREA U —27-2 PB1/37,39,411 PB3/3: PB2/1 ti PB2/14 i'PB2. COOK MCOR PB1/9 PB1/17 MEETING t{C,i,r;; 4 194 17-7-0131 /1 A L ,• r 71T VAV-6 MEF AKW/277 RC nk, • PB1/22 r,PB1/20 111 1PH (E3 \PB3/8 P81/1 � B1/15 PB2/188 rij CLASSROOM C� I, .. PB3/6 6U41) 111F4 PB3/6 n OD IPPB 01 P62/38,40,42 OD pppp,,P,83/6 ,,4TPRThl'S AREA IEETINO ROOM B1/19 PBj/1 1382' PB3/9, 1 g -J SECOND FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" b 17 20 PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98.104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.8448 Seattle, Washington 98104 fax: (206)223.6465 EXPIRES I-17-18 ISSUE / REVISIONS ID Jut 282017 pER44I rCENro Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR POWER AND SIGNAL PLAN E2.2 CCLA.EISROOM PB3/3: PB2/1 ti PB2/14 i'PB2. COOK MCOR PB1/9 PB1/17 MEETING t{C,i,r;; 4 194 17-7-0131 /1 A L ,• r 71T VAV-6 MEF AKW/277 RC nk, • PB1/22 r,PB1/20 111 1PH (E3 \PB3/8 P81/1 � B1/15 PB2/188 rij CLASSROOM C� I, .. PB3/6 6U41) 111F4 PB3/6 n OD IPPB 01 P62/38,40,42 OD pppp,,P,83/6 ,,4TPRThl'S AREA IEETINO ROOM B1/19 PBj/1 1382' PB3/9, 1 g -J SECOND FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" b 17 20 PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98.104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.8448 Seattle, Washington 98104 fax: (206)223.6465 EXPIRES I-17-18 ISSUE / REVISIONS ID Jut 282017 pER44I rCENro Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR POWER AND SIGNAL PLAN E2.2 GENERAL NOTES: 1. SOLID/HEAVY LINE WORK INDICATES NEW OR RELOCATED FIXTURES AND/OR DEVICES. 2. DASHED/LIGHT LINE WORK INDICATES EXISTING FIXTURES AND/OR DEVICES TO REMAIN 3. RELOCATED FIXTURES TO BE RECONNECTED, EXTEND CONDUCTORS IF REQUIRED TO EXISTING 277V CIRCUIT SERVING NEW LOCATION UNLESS NOTED OTHERWISE. 4. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 5. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES ARE TO BE RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH NEW PHOTOCELL DEVICES AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 6. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAY AS INDICATED/REQUIRED. 7. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: RELOCATED SWITCH(S). SEE SHEET ED1.2 FOR PREVIOUS LOCATION. RELOCATED OCCUPANCY SENSOR. SEE SHEET ED1.2 FOR PREVIOUS LOCATION. EXISTING RELOCATED FIXTURE TO BE RETROFITTED WITH A 0-10V DIMMING BALLAST TO ALLOW DIMMING REQUIRED FOR DAYLIGHT HARVESTING. 120V VANITY FIXTURE TO BE CONTROLLED VIA OCCUPANCY SENSOR. POWER TO BE PROVIDED BY CLOSEST GENERAL RECEPTACLE 120V CIRCUIT. TT ELECTJJANITOR II p II p E13A Irz g R::STRO 1f;,_ El a E1 E , El II CII , I,_Jv .' apb 'l.il'UI T =='E1 \7 1T=1E1._. II ,, 11 II ._. _. II II b ,I II cop?/ n ;iL ;os; STORA(E — 1E1 II II i i:NG II II jl Ri)Civ1 II II I� "OWEN, R1 1TRoof.1 T== E1 //2//201/ 11:bb AM DOHS WORKSOURCE (WJA)\CARD\1/030 ._.. a... __r 3a=_.tee II I p 11 p 3b -L`--`=__— I_.L _r-0 .. .. SE1 10f1� E1 _, COr f LJ1 [_t; tF' _ l II — E 1 ;iE1E A Ij Psi IN T ANCE LIA STORAGE O FIRST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" .STORAGE 11:?..1„) bra/ O2.10I NORTH PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S. Suite 2C tel: (206)2236446 Seattle, Washington 98104 fax: (206)2236465 EXPIRES I—17-18 H ww cew �oa O� O�� U z C.9 Q = Z YEN ISSUE / REVISIONS (25 0 J M SIV 00 c4C C31 ILiM CI - 41( W O:5 J Z �--� Q fd^' CI7Y4�fie1VED JUL2 8 2011PERAilr CENTER f_ Project No.: 15032-17ZA Site No.: ....... ..... ...... . . Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR LIGHTING PLAN E3.1 //2//201/ 11:56 AM GENERAL NOTES: 1. SOLID/HEAVY UNE WORK INDICATES NEW OR RELOCATED FIXTURES AND/OR DEVICES. 2. DASHED/LIGHT LINE WORK INDICATES EXISTING FIXTURES AND/OR DEVICES TO REMAIN 3. RELOCATED FIXTURES TO BE RECONNECTED, EXTEND CONDUCTORS IF REQUIRED TO EXISTING 277V CIRCUIT SERVING NEW LOCATION UNLESS NOTED OTHERWISE. 4. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOUIION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 5. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES ARE TO BE RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH NEW PHOTOCELL DEVICES AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 6. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAY AS INDICATED/REQUIRED. 7. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: RELOCATED SWITCH(S). SEE SHEET ED1.4 FOR PREVIOUS LOCATION. RELOCATED OCCUPANCY SENSOR. SEE SHEET ED1.4 FOR PREVIOUS LOCATION. EXISTING RELOCATED FIXTURE TO BE RETROFITTED WITH A 0-10V DIMMING BALLAST TO ALLOW DIMMING REQUIRED FOR DAYLIGHT HARVESTING. os; El II e II u El c j L. " 0 >.a j .♦ ... C ��\ \\ J IL, \ I, A.f Q 1_AC i1PO'i oR r -------y LJ - ElE NL 14 EMX1E NL it - SECURED FIL SECIUR DILE s rc t Gk _., a..• Rod NI Ii 1 -1E3 a HE3 a 'EDTIONi INC. r'.Ii r ------a II I b El a "E3 b_ HE3 b_ HE3 F'-- I 1- OPEN,' SECOND FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" br7 SCALE: 1/8" =1-0" 8' 16' NORTH SEP PE A 32RE R1 King C i unty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.6446 Seattle, Washington 98104 lax: (206)2236465 EXPIRES I-17-18 0 m co ce co I.I. LU o 0J z Q 5 L!7 � to I- 0_017_41' a ISSUE / REVISIONS RIE PERMIT SET - JULY 21, 2017 DL:SCHP RDN CITE. Ofee IVED 2 8 2017 JUL Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR LIGHTING PLAN E3.2 LL. I rOII 'EDTIONi INC. r'.Ii r ------a II I b El a "E3 b_ HE3 b_ HE3 F'-- I 1- OPEN,' SECOND FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" br7 SCALE: 1/8" =1-0" 8' 16' NORTH SEP PE A 32RE R1 King C i unty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.6446 Seattle, Washington 98104 lax: (206)2236465 EXPIRES I-17-18 0 m co ce co I.I. LU o 0J z Q 5 L!7 � to I- 0_017_41' a ISSUE / REVISIONS RIE PERMIT SET - JULY 21, 2017 DL:SCHP RDN CITE. Ofee IVED 2 8 2017 JUL Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR LIGHTING PLAN E3.2 GENERAL NOTES: 1. EXISTING CONDITIONS INDICATED ON PLANS ARE FROM AS—BUILT DOCUMENTATION AND ARE SHOWN FOR CLARIFICATION AND TO BE FIELD VERIFIED/CONFIRMED BY ELECTRICAL CONTRACTOR. 2. LOADS INDICATED ON PANEL SCHEDULES CONFIRM EXISTING PANELS/SERVICE IS ADEQUATE TO SUPPORT NEW TENANT SPACE LOADS (SEE SHEETS E6.1, E6.2, E6.3) 3. SCOPE OF WORK PANELS ARE EXISTING. TENANT SPACE OCCUPANCY REMAINS THE SAME WITH CIRCUITS BEING RE—PURPOSED. LOAD CALCULATIONS SHOWN FOR LOCAL PANELS ONLY BASED ON RE—PURPOSING OF LIKE TENANT SPACE. 4. EXISTING CONDITIONS INDICATED ON PLANS ARE FROM AS—BUILT DOCUMENTATION AND ARE SHOWN FOR CLARIFICATION AND TO BE FIELD VERIFIED/CONFIRMED BY ELECTRICAL CONTRACTOR. PANE S IN SCOPE OF WORK: 7/27/2017 11:56 AM 1<.11.>I EXISTING 1 112.5KVA r¢1 r I I L I I 01=1 =010 0111011 I- L, PANEL PANEL PB1 PB2 208/120V1— —12 /120V 200A 100A MLO MLO PANEL PB3 208/120V 40A MCB 011011010 I I FLAG NOTES EXISTING BRANCH PANEL CIRCUITS TO BE MODIFIED. LOAD MODIFICATIONS SHOWN ON PANEL SCHEDULES SHEETS E6.1, E6.2, E6.3. L 4 6X6X48 WIREWAY J' .1 -� EXISTING HVAC ROOFTOP UNIT L PANELS IN SCOPE OF WORK: L_ I I PANEL LA 480/277V 200A MLO 1=11 111=1 .i T I— PANEL I LB I 480/277V I 100A I MLO I PANEL IN SCOPE OF WORK: PANEL LB L 1 800AF/800AS 400AF/400AS I GR I - - --CLI''— - -� CR 400AF/400AS 1 GFI 200AF/200AS L___-+-_-�iI�'''`'--� GFI PANEL PA1 208/120V 200A MLO PANEL PA2 208/120V 100A MLO _ J ,11� I-- — — 14:11:>1 1 EXISTING --1--- 15KVA PANEL ATRIUM BUILDING 6 Ci)PARTIAL RISER DIAGRAM SCALE: NONE I I PANEL HV 200AF/200AS -----au----- GFI SPACE — — — SPACE— — - I 480/277V PANEL IN SCOPE OF WORK: 400A MLO L J Ifr l.Q-Ft9RE_ bn 0201 ER�� APPROV ND REQUIRED PERMIT SET - JULY 21, 2017 King C unty Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (208)2238448 Seattle, Washington 98104 fax: (206)2236465 EXPIRES 1-17-18 ISSUE / REVISIONS D 11),/,DE; CHIFTIONi OF RECEIVED CITY W �wr JUL 28Z017_ PERMIT CENTER A Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PARTIAL RISER DIAGRAM E5.1 PANEL SCHEDULE PANEL: MDP LOCATION: ELECT ROOM LEVEL 1 VOLTS: 480 Y/277V P: AIC RATING: <-SEE RISER DIAGRAM >000c NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 800 MLO X MCB MOUNT: X SURFACE D FLUSH TYPE: EXISTING X NEW STYLE: YES FED FROM: MAIN DISTRIBUTION PANEL CIRCUIT DESCRIPTION LOAD LOAD CKT P CIR P CIR P CKT LOAD LOAD CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION TYPE KVA BKR 3 # H # 1 BKR KVA TYPE CIRCUIT DESCRIPTION TRANSFORMERT-6-(PANELS PAI &PB1) COMB 3920 400 3 1 A 2 3 400 48.07 MISC PANEL HV COMB COMB 33.71 - - - B - - - 50.91 COMB - 7 COMB 35.74 -- 8 - C - - - 51.81 COMB 10 ROOFTOP UNIT MTR 36.56 200 3 3 A 4 3 200 16.63 COMB PANEL LA - MTR 36.56 -- 5.67 - B - - - 24.56 COMB - - MTR 36.56 -- - - 3 - - 3 - C - - - 17.63 COMB - 18 1 40 40 7.33 7.33 7.33 6.08 MISC MISC MISC MISC 5 A 6 MISC MISC 24 26 1 19 20 1 - - 27 SPACE - B - MISC - 1 21 22 1 - 3 29 31 30 32 SPACE SPACE - C - 1 23 24 1 --- 33 34 SPACE SPACE SPACE ---- --- __ ___. ....---....------------ SPACE SPACE SPARE - - 1 25 26 28 - 30 32 1 1 --- -- 1 - - -- - ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS - 20 LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED 1 27 LIGHTING LTG 23.32 KVA 29.15 KVA (125%) MISC 3 CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) 29 SPARE PHASE A: 140.46 KVA 507 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) - PHASE B: 145.74 KVA 526 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) 1 PHASE C: 141.74 KVA 512 AMPERES REMAINING MOTORS MTR 144.77 KVA 144.77 KVA (100%) SPACE - GEN PURPOSE RECPT REC 79.89 KVA 44.95 KVA (50%> 10KVA) SPACE 1 COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) 34 GENERAL NOTES: -- EQUIP/OTHER MISC 4.40 KVA 4.40 KVA (100%) 41 1 SPACE HEATING MISC 174.71 KVA 174.71 KVA (100%) MISC - ELEVATOR [0 Total] ELEV 0.00 KVA 0.00 KVA (100%) 35 36 KITCHEN El [0 Total] KITCH 0.85 KVA 0.85 KVA (100%) 1 35 TOTALS 427.94 KVA 398.83 KVA SPACE FLAG NOTES: 515 AMPS 480 AMPS ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 1 37 LOAD TYPE NOTES: 3 20 LIGHTING • LTG 4.70 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 1.87 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 144.22 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 150.79 KVA 181 AMPS LOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT VAV BOX SPACE 1.70 "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND LIGHTING - ROOMS 6209, 6210 1 "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100% 40- 20 PANEL SCHEDULE PANEL: LA LOCATION: ELECT ROOM LEVEL 1 VOLTS: 480 Y/277V P: AIC RATING: <-SEE RISER DIAGRAM >000t NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 200 MLO X MCB MOUNT: X SURFACE J FLUSH TYPE: EXISTING X NEW STYLE: FED FROM: MAIN DISTRIBUTION PANEL NO CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION PANEL LB COMB 16.63 100 3 1 A B C A B C A B C A B C A B C A B C A B C 2 1 30 4.33 MISC FACULTYAREA, DH '3' EAST END LIGHTS - PERIMETER - COMB 24.56 - - 3 4 1 4.34 MISC - - LIGHTS - SOUTH PERIMETER - COMB 17.63 - - 5 6 1 MISC - #1 UNIT HEATER FIRST FLOOR MISC SPACE VAV BOX 3 7 8 1 7 8 1 - MISC 3.33 SPACE VAV BOX 9 10 - 1 9 10 1 MISC 3.33 - VAV BOX SPARE 12 - - 1 11 12 1 5.67 30 3 SPACE VAV BOX _ VAV BOX 3 30 5.67 1 1 13 15 14 16 1 1 - - 30 - 30 - - 3 - - 3 15 17 19 VAV BOX VAV BOX SPACE - - 5.67 5.67 MISC- 1 17 18 1 40 40 7.33 7.33 7.33 6.08 MISC MISC MISC MISC VAV BOX SPACE - MISC MISC 24 26 1 19 20 1 - - 27 SPACE SPACE - 6.08 MISC - 1 21 22 1 - 3 29 31 30 32 SPACE SPACE 6.08 MISC - SPACE 1 23 24 1 --- 33 34 SPACE SPACE SPACE ---- --- __ ___. ....---....------------ SPACE SPACE SPARE - - 1 25 26 28 - 30 32 1 1 --- -- 1 - - -- - SPARE - 20 - 1 27 SPARE MISC 3 37 1 29 SPARE SPACE - 1 31 1 1 39 SPACE - - SPACE 1 33 34 1 -- 33 41 SPACE SPACE - MISC - 1 35 36 1 1 35 36 SPACE SPACE ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 1 37 38 3 20 LIGHTING • LTG 4.70 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 1.87 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 144.22 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 150.79 KVA 181 AMPS LOAD TYPE NOTES: 5.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 0.00 KVA (100%) 1.87 KVA (50%> 10KVA) 0.00 KVA (100%) 0.00 KVA (100%) 144.22 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 151.97 KVA 183 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% VAV BOX SPACE 1.70 1 FLAG NOTES: LIGHTING - ROOMS 6209, 6210 1 39 40- 20 1 39 40 1 SPACE1 SPACE LIGHTING - ROOMS 6225, 6213, 6214 41 42 - 1 41 42 - ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS CONNECTED PHASE LOADING LIGHTING LTG 7.10 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 26.33 KVA GEN PURPOSE RECPT REC 0.40 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 24.99 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 58.82 KVA 71 AMPS LOAD TYPE NOTES: 8.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 26.33 KVA (100%) 0.40 KVA (50%> 1OKVA) 0.00 KVA (100%) 0.00 KVA (100%) 24.99 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 60.60 KVA 73 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 16.63 KVA 61 AMPERES PHASE B: 24.56 KVA 89 AMPERES PHASE C: 17.63 KVA 63 AMPERES GENERAL NOTES: LIGHTING LTG 7.10 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 26.33 KVA GEN PURPOSE RECPT REC 0.40 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 24.99 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 58.82 KVA 71 AMPS LOAD TYPE NOTES: 1 FLAG NOTES: PHASE A: 16.63 KVA 61 AMPERES PHASE B: 24.56 KVA 89 AMPERES PHASE C: 17.63 KVA 63 AMPERES 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED PANEL SCHEDULE PANEL: HV LOCATION: ELECT ROOM LEVEL 1 VOLTS: 480 Y/277V P: AIC RATING: <-SEE RISER DIAGRAM >000c NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 400 MLO X MCB MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW STYLE: NO FED FROM: MAIN DISTRIBUTION PANEL CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION BATHROOM HEAT 20 1 1 A B C A B C A B C A B C A B C A B C A B C 2 3 30 4.33 MISC FACULTYAREA, DH '3' EAST END 15KVA TRANSFORMER TO PANEL ATRIUM COMB 2.83 30 2 3 4 - - 4.34 MISC - - COMB 3.74 - - 5 6 - - 4.33 MISC - #1 UNIT HEATER FIRST FLOOR MISC 3.33 20 3 7 8 3 30 4.33 MISC DH '7' 2ND FLOOR - MISC 3.33 - - 9 10 - - 4.34 MISC - - MISC 3.33 - - 11 12 - - 4.33 MISC - #3 UNIT HEATER FIRST FLOOR MISC 5.67 30 3 13 14 3 30 5.67 MISC DH '8' 2ND FLOOR - MISC MISC MISC MISC 5.67 5.67 5.67 5.67 5.67 5.67 - - 30 - 30 - - 3 - - 3 15 17 19 16 18 - - - - 5.67 5.67 MISC- MISC - #2 UNIT HEATER 1ST FLOOR #4 UNIT HEATER 1ST FLOOR 20 22 3 3 40 40 7.33 7.33 7.33 6.08 MISC MISC MISC MISC DH '9' 2ND FLOOR 21 23 25 - MISC MISC 24 26 - ATRIUM A/C & HEAT. 10 TON UNIT -ROOF - MISC 5.67 - - 27 28 - - 6.08 MISC - - SPARE MISC 5.67 - 100 - 3 29 31 30 32 - 3 - 6.08 MISC - SPACE - 23 24 26 28 30 -- ------ 20 33 34 - - - - 1 1 25 27 -- REC 35 36 - - 20 - SPACE REC - WATER HEATER DUCT HEATER MISC 3 37 38 3 SPACE - -- 1 39 40 - - SPACE - - 20 -- 33 41 42 - - MISC - SPARE 20 1 35 36 1 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LIGHTING - ROOMS 6208, 6211, 6212 LTG LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED 20 CONNECTED PHASE LOADING LIGHTING • LTG 4.70 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 1.87 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 144.22 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 150.79 KVA 181 AMPS LOAD TYPE NOTES: 5.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 0.00 KVA (100%) 1.87 KVA (50%> 10KVA) 0.00 KVA (100%) 0.00 KVA (100%) 144.22 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 151.97 KVA 183 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 48.07 KVA 173 AMPERES PHASE B: 50.91 KVA 184 AMPERES PHASE C: 51.81 KVA 187 AMPERES GENERAL NOTES: 1.70 1 FLAG NOTES: LIGHTING - ROOMS 6209, 6210 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED PANEL SCHEDULE PANEL: LB LOCATION: ELECT ROOM LEVEL VOLTS: 480 Y/277V P: AIC RATING: <-SEE RISER DIAGRAM >000( NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 100 MLO X MCB ❑ MOUNT: X SURFACE U FLUSH TYPE: EXISTING X NEW U STYLE: NO FED FROM: PANEL LA CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION SPACE 1 A B C A B C A B C A B C A B C A B C A B C 2 3 20 3.20 MTR AC -6-1 SPACE 3 4- 3.20 MTR - SPACE 5 6- 3.20 MTR - SPACE 7 8 3 20 2.60 MTR AC -6-2 SPACE 9 10- 2.60 MTR - SPACE 11 12- 2.60 MTR - SPACE EDH-2 MISC 4.33 20 3 13 15 14 16- 3 20 2.80 2.80 MTR MTR EDH-1 - - MISC 4.3317 18 - 2.80 MTR - - MISC 4.33 - 19 20 1 SPACE VAV-6-111 (3KW HEAT) COMB 3.53 20 1 21 22 1 SPACE SPARE 20 1 23 24 26 28 30 1 ----- 1 ------ 20 SPACE SPARE 3.00 20 20 1 1 25 27 0.20 REC REC - WATER HEATER DUCT HEATER MISC 1 1 1 20 0.20 REC REC - WATER HEATER DUCT HEATER MISC 3.00 20 1 29 SPACE BATH HEATER 20 1 31 32 SPACE SPARE 20 1 33 34 1 20 3.00 MISC DUCT HEATER SPARE 20 1 35 36 1 SPACE LIGHTING - ROOMS 6208, 6211, 6212 LTG 1.80 20 1 37 38 1 20 1.70 LTG LIGHTING - ROOMS 6209, 6210 LIGHTING - ROOMS 6216, 6217, 6218, 6219, 6220, 6221 LTG 1.90 20 1 39 40 1 SPACE LIGHTING - ROOMS 6225, 6213, 6214 LTG 1.70 20 1 41 42 1 SPACE ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED CONNECTED PHASE LOADING LIGHTING LTG 7.10 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 26.33 KVA GEN PURPOSE RECPT REC 0.40 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 24.99 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 58.82 KVA 71 AMPS LOAD TYPE NOTES: 8.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 26.33 KVA (100%) 0.40 KVA (50%> 1OKVA) 0.00 KVA (100%) 0.00 KVA (100%) 24.99 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 60.60 KVA 73 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 16.63 KVA 61 AMPERES PHASE B: 24.56 KVA 89 AMPERES PHASE C: 17.63 KVA 63 AMPERES GENERAL NOTES: 1 FLAG NOTES: 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED MDP PANEL HV PANEL LA PANEL LB br7 %0 0201 PSE PARATE APPROVAL OVAL REQUIRED PERMIT SET - JULY 21, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (208 223-6446 Seattle, Washington 98104 fax: (2061223-6465 I EXPIRES I-17-18 (n H • Z W W ct W Oa O� O�� U z zQ z U YAH ISSUE / REVISIONS L) DATE D ;CPIP i_ION crrynec, enV D TUKWILA JUL 28 20» PEi G Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES E6.1 PANEL SCHEDULE PANEL: ATRIUM LOCATION: ELECT ROOM LEVEL 1 VOLTS: 120 /208V P: 1 AIC RATING: .--SEE RISER DIAGRAM PONY STYLE NEUTRAL: 100% W: 3 AMP: 80 MLO X MCB MOUNT: X SURFACE FLUSH TYPE: EXISTING NEW X STYLE: FED FROM: PANEL HV (via 15KVA xfmr) CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION MAIN BREAKER CIRCUIT DESCRIPTION 60 2 1 A B A B A B A B 2 1 20 0.35 LTG 1ST FLOOR CAN LIGHTS REC - CIRCUIT DESCRIPTION PANEL PA2 - - 3 4 1 20 0.36 REC 2ND FLOOR SOFFIT LIGHTS LTG 0.80 20 1 5 6 1 20 0.36 REC REC - INTERIOR CAN LIGHTS LTG 0.91 20 1 7 8 1 20 0.54 REC REC - EXTERIOR SOFFIT LIGHTS LTG 0.35 20 1 9 10 1 20 0.25 REC REC - FLOOR ATRIUM LIGHTS LTG LTG 1.00 20 1 1 11 13 12 14 1 1 20 20 0.25 0.18 LTG REC OLS ENTRY LIGHTS ATRIUM RECEPTACLE ATRIUM RECEPTACLE ATRIUM RECEPTACLE 0.54 20 ATRIUM LIGHT LTG 0.50 20 1 15 16 1 20 0.18 REC C 12 1 20 0.90 REC REC -CONFERENCE ROOM 118 REC-ADMISSIONS REC 0.54 20 1 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS A 14 LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED 20 CONNECTED PHASE LOADING LIGHTING LTG 4.70 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 1.87 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 0.00 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA --------- TOTALS 6.57 KVA 32 AMPS LOAD TYPE NOTES: 5.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 0.00 KVA (100%) 1.87 KVA (50%> 10KVA) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) ---------- 7.75 KVA 37 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 2.83 KVA 14 AMPERES PHASE B: 3.74 KVA 18 AMPERES GENERAL NOTES: & (B) ALL MULTIWIRE BRANCH CIRCUITS SHARING ACOMMON NEUTRAL WIRE WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED AT THE POINT OF ORIGIN. CONTRACTOR'S CHOICE: PROVIDE SEPARATE NEUTRALS AS INDICATED OR PROVIDE MULTIPOLE BREAKER FOR SHARED NEUTRAL. 1 PER NEC 210.4(A) MUST BE PROVIDED CONDUCTORS FOR BREAKER FLAG NOTES: 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED 7/27/2017 11:56 AM PANEL SCHEDULE PANEL: PA1 LOCATION: ELECT ROOM LEVEL 1 VOLTS: 208 Y/120V P: AIC RATING: <-SEE RISER DIAGRAM )000( NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 200 MLO X MCB MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW LJ STYLE: NO FED FROM: MAIN DISTRIBUTION PANEL LOAD LOAD CKT P CIR P CIR P CKT LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA BKR # H # BKR KVA TYPE CIRCUIT DESCRIPTION PANEL PA2 COMB 11.55 100 3 1 A 2 1 20 0.90 REC REC - MEETING ROOM 116 - COMB 8.82 - - 3 B 4 1 20 0.54 REC REC - MEETING ROOM 117 - COMB 9.95 - - 5 C 6 1 20 0.54 REC REC - MEETING ROOM 111 REC -WAITING 106,RECEPTION 107A, ADMIN 1078 REC 1.08 20 1 7 A 8 1 20 1.44 REC REC - MEETING ROOM 112,113 REC -WAITING 106 REC 0.18 20 1 9 B 10 1 20 0.72 REC REC - MEETING ROOM 114 REC -MEETING ROOM 107C REC 0.54 20 1 11 C 12 1 20 0.90 REC REC -CONFERENCE ROOM 118 REC-ADMISSIONS REC 0.54 20 1 13 A 14 1 20 0.18 REC REC-CORRIDOR REC - ADMISSIONS REC 0.36 20 1 15 B 16 1 20 0.18 REC REC - MDF ROOM IN CEILING REC - NW REC 0.90 20 1 17 C 18 1 20 0.72 REC REC - PERIMETER EAST REC - NW REC 0.72 20 1 19 A 20 1 20 0.72 REC REC - PERIMETER NORTH FACP MISC 0.20 20 1 21 B 22 1 20 0.20 REC REC - MECHANICAL, RESTOOM, & IRRIGATOR ENTRANCE FLOOD LIGHTS LTG 0.12 20 1 23 C 24 1 20 0.15 LTG RESTROOM LIGHTS MECHANICAL ROOM DRYER REC 1.08 20 1 25 A 26 1 20 0.30 LTG EXTERIOR LIGHTS REC - MEETING RM, CORRIDOR STATIONS TIE HANDLE REC 1.26 20 1 27 B 28 1 20 0.10 LTG SOFFIT LIGHTS REC - MEETING RM, CORRIDOR STATIONS TIE HANDLE REC 1.08 20 1 29 C 30 1 20 0.10 LTG SOFFIT LIGHTS HOT WATER HEATER MISC 2.25 30 2 31 A 32 1 20 1.00 MTR MECHANICAL ROOM COMPRESSOR TIE HANDLE - MISC 2.25 - - 33 B 34 1 20 1.00 MTR MECHANICAL ROOM COMPRESSOR TIE HANDLE REC (FURNITURE) -COMPUTER LAB REC 0.72 20 1 35 C 36 1 15 0.36 REC FURNITURE RECEPTACLES REC (FURNITURE) - COMPUTER LAB REC 0.72 20 1 37 A 38 1 20 0.18 REC REC - MDF ROOM IN CEILING REC (FURNITURE) -COMPUTER LAB REC 0.72 20 1 39 B 40 1 20 0.18 REC REC - MDF ROOM IN CEILING REC (FURNITURE) - COMPUTER LAB REC 0.72 20 1 41 C 42 1 20 0.18 REC REC - MDF ROOM IN CEILING ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED LIGHTING LTG 5.62 KVA 7.03 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE A: 21.58 KVA 180 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE B: 16.71 KVA 139 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) PHASE C: 16.98 KVA 141 AMPERES REMAINING MOTORS MTR 8.26 KVA 8.26 KVA (100%) CONNECTED PHASE LOADING GEN PURPOSE RECPT REC 33.14 KVA 21.57 KVA (50%> 10KVA) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) GENERAL NOTES: PHASE B: 8.82 KVA 73 AMPERES EQUIP/OTHER MISC 1.90 KVA 1.90 KVA (100%) 1 BOLD INDICATES NEW OR LOAD MODIFICATIONS. HEATING MISC 5.50 KVA 5.50 KVA (100%) GEN PURPOSE RECPT REC 15.66 KVA 12.83 KVA (50%> 10KVA) ELEVATOR [0 Total] ELEV 0.00 KVA 0.00 KVA (100%) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) KITCHEN El [0 Total] KITCH 0.85 KVA 0.85 KVA (100%) GENERAL NOTES: TOTALS 55.27 KVA 45.11 KVA FLAG NOTES: LOAD MODIFICATIONS. 153 AMPS 125 AMPS 1 ELEVATOR [0 Total) ELEV 0.00 KVA 0.00 KVA (100%) LOAD TYPE NOTES: KITCHEN El [0 Total] KITCH-- 085 KVA 0.85 KVA (100%) "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT -- TOTALS 30.32 KVA 28.70 KVA FLAG NOTES: "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND 84 AMPS 80 AMPS "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100% LOAD TYPE NOTES: PANEL SCHEDULE PANEL: PA2 LOCATION: ELECT ROOM LEVEL 1 VOLTS: 208 Y/12OV P: AIC RATING: <-SEE RISER DIAGRAM xxxx NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 100 MLO X MCB MOUNT: X SURFACE J FLUSH TYPE: EXISTING X NEW LJ STYLE: NO FED FROM: PANEL PA1 LOAD LOAD CKT P CIR P CIR P CKT LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA BKR # H # BKR KVA TYPE CIRCUIT DESCRIPTION REC - MDF ROOM REC 1.44 20 1 1 A 2 1 20 0.54 REC REC - MAIL/FAX/COPY CORRIDOR TRACK LIGHTS LTG 1.25 20 1 3 B 4 1 20 1.20 MISC REC - COPIER CORRIDOR TRACK LIGHTS LTG 0.80 20 1 5 C 6 1 20 0.54 REC REC - MEETING ROOM 123 REC - LIBRARY REC 0.90 20 1 7 A 8 1 20 1.08 REC REC (FURNITURE) - OPEN OFFICE 122 REC - LIBRARY REC 0.72 20 1 9 B 10 1 20 1.08 REC REC (FURNITURE) - OPEN OFFICE 122 REC- CORRIDOR REC 0.72 20 1 11 C 12 1 20 REC-ADJUNCT FACILITY REC-FACULTY LOUNGE REC 0.36 20 1 13 A 14 1 20 REC ADJUNCT FACILITY REC - REFRIGERATOR TV KITCH 0.85 20 1 15 B 16 1 20 1.08 REC REC (FURNITURE) OPEN OFFICE 122 REC FACULTY LOUNGE REC 0.54 20 1 17 C 18 1 20 1.08 REC REC(FURNITURE)-OPENOFFICE122 REC SURGE PUMP MTR 1.20 20 1 19 A 20 1 20 0.50 MISC ADA DOOR ACTUATORS -ENTRY 105 REC DIRECTOR OF STUDENT MANAGEMENT 20 1 21 B 22 1 20 SPARE REC (FURNITURE) • OPEN OFFICE 121 REC 1.08 20 1 23 C 24 1 20 SPARE REC (FURNITURE) • OPEN OFFICE 121 REC 1.08 20 1 25 A 26 1 20 SPARE REC (FURNITURE) • OPEN OFFICE 121 REC 1.08 20 1 27 B 28 1 20 SPARE REC (FURNITURE) • OPEN OFFICE 121 REC 1.08 20 1 29 C 30 1 20 0.08 MTR EF -1 - RESTROOM 132 AC6-1-1-FAN 20 2 31 A 32 1 20 1.60 LTG CORRIDOR TRACK LIGHT - - - 33 B 34 1 20 1.20 LTG CORRIDOR TRACK LIGHT AC6-1-1-CONDENSOR MTR 2.49 30 2 35 C 36 1 20 0.36 REC REC -TELECOM 131 - MTR 2.49 - - 37 A 38 1 20 0.36 REC REC -TELECOM 131 REC - VP FINANCE 20 1 39 B 40 1 20 0.36 REC REC - TELECOM 131 REC -STORAGE RESOURCES 120 REC 0.18 20 1 41 C 42 1 20 1.00 MISC OUTSIDE HEAT TAPE ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED LIGHTING LTG 4.85 KVA 6.06 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE A: 11.55 KVA 96 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE B: 8.82 KVA 73 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) PHASE C: 9.95 KVA 82 AMPERES REMAINING MOTORS MTR 6.26 KVA 6.26 KVA (100%) GEN PURPOSE RECPT REC 15.66 KVA 12.83 KVA (50%> 10KVA) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) GENERAL NOTES: EQUIP/OTHER MISC 1.70 KVA 1.70 KVA (100%) 1 BOLD INDICATES NEW OR LOAD MODIFICATIONS. HEATING MISC 1.00 KVA 1.00 KVA (100%) ELEVATOR [0 Total) ELEV 0.00 KVA 0.00 KVA (100%) KITCHEN El [0 Total] KITCH-- 085 KVA 0.85 KVA (100%) -- TOTALS 30.32 KVA 28.70 KVA FLAG NOTES: 84 AMPS 80 AMPS 1 LOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100% PANEL ATRIUM PANEL PA1 - PANEL PA2 bri 0201 PERARATE MITAND APPROVAL QUIRED PERMIT SET - JULY 21, 2017 Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (206)223-6446 Seattle, Washington 98104 fax: (206)223.6465 EXPIRES I-17-18 0 J m MM W co L.L. LU S o� J Z H Q Lr) H ISSUE / REVISIONS C!rpOP ling4071.4 tivvd JUL 2 8 2017 Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES (2) E6.2 PANEL SCHEDULE PANEL: PB3 LOCATION: ELECT ROOM LEVEL VOLTS: 208 Y/120V• P: AIC RATING: <-SEE RISER DIAGRAM ;ooc< NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 40 MLO X MCB MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW STYLE: NO FED FROM: PANEL PB1 CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION HVAC TRANSFORMER REC - CORRIDOR 6211, ROOM 6210 REC 0.70 20 20 1 1 1 3 A B C A B C 2 4 6 1 1 1 20 20 20 0.40 0.50 0.90 REC REC REC REC - ROOM 6213 REC - ROOMS 6214, 6215 REC - ROOMS 6210, 6213 REC 0.90 20 1 5 REC -CLASSROOMS 'B' 208, CLASSROOM 'C2' 211 PROJECTOR - ROOMS 6213, 6214 FURNITURE -OPEN OFFICE 216 REC REC 0.36 0.72 20 20 1 1 7 9 8 10 1 1 20 20 0.40 0.50 REC LTG REC - ROOMS 6210, 6214 LIGHTING -SE STAIRS FURNITURE -OPEN OFFICE 216 REC 0.72 20 1 11 12 1 20 0.50 LTG LIGHTING -SOUTH - SIGN 5 C 6 1 20 0.20 REC REC - CLASSROOM 'A' 225 LIGHTING NW STAIRS LTG 0.50 20 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 7 A LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED 1 CONNECTED PHASE LOADING LIGHTING LTG 1.00 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 5.60 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 0.00 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 6.60 KVA 18 AMPS LOAD TYPE NOTES: 1.25 KVA (125%) 0.00 KVA(100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 0.00 KVA (100%) 5.60 KVA (50%> 10KVA) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 6.85 KVA 19 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUITAT 100% PHASE A: 1.16 KVA 10 AMPERES PHASE B: 2.42 KVA 20 AMPERES PHASE C: 3.02 KVA 25 AMPERES GENERAL NOTES: LOAD MODIFICATIONS. 1 BOLD INDICATES FLAG NOTES: NEW OR 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED 7/27/2017 12:14 PM PANEL SCHEDULE PANEL: PBI LOCATION: ELECT ROOM LEVEL 2 VOLTS: 208 Y/120V P: AIC RATING: <-SEE RISER DIAGRAM >000< NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 200 MLO MCB X MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW STYLE: FED FROM: MAIN DISTRIBUTION PANEL (via T-6) NO CIRCUIT DESCRIPTION LOAD LOAD CKT P CIR P CIR P CKT LOAD LOAD CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION TYPE KVA BKR 1 # H # 1 BKR KVA TYPE CIRCUIT DESCRIPTION REC - HALL, MEETING ROOM 206 REC 0.54 20 1 1 A 2 1 20 0.20 REC REC - CLASSROOM 'A' 225 REC - RESOURCES AND COMPUTERS 201 REC 0.72 20 1 3 B 4 1 20 0.20 REC REC - CLASSROOM 'A' 225 REC - RESOURCES AND COMPUTERS 201 REC 0.72 20 1 5 C 6 1 20 0.20 REC REC - CLASSROOM 'A' 225 LIGHTING NW STAIRS LTG 0.50 20 1 7 A 8 1 20 0.50 REC PROJECTOR -CLASSROOM 'A' 225 REC - MEETING ROOMS 202, 203 REC 0.72 20 1 9 B 10 1 20 20 20 SPARE REC - WELLNESS ROOM 227 REC 0.54 20 1 11 C 12 1 20 0.72 REC REC - WEST WALL OPEN OFFICE LIGHTING - BATH/ELECTRIC ROOMS LTG 0.80 20 1 13 A 14 1 20 0.72 REC FURNITURE (CONTROLLED) -CENTRAL OPEN OFFICE REC - CLASSROOM B 208, MEETING RM 202 REC 0.90 20 1 15 B 16 1 20 0.72 REC FURNITURE - CENTRAL OPEN OFFICE . REC - MEETING RMS 206, 207 REC 0.72 20 1 17 C 18 1 20 0.70 20 20 SPARE REC - CLASSROOM 'A' 225, MTG 215, OPEN OFFICE 216 REC 1.08 20 1 19 A 20 1 20 0.36 REC REC - MEETING ROOMS 202,203 LIGHTING - OUTSIDE SOFFIT LTG 0.70 20 1 21 B 22 1 20 0.36 REC REC - MEETING ROOM 202 LIGHTING - OUTSIDE SOFFIT LTG 0.70 20 1 23 C 24 1 20 1.62 REC FURNITURE (CONTROLLED) -CENTRAL OPEN OFFICE EF - BATH MTR 0.50 20 1 25 A 26 1 20 0.90 REC FURNITURE -CENTRAL OPEN OFFICE REC - RECEPTION 203, MEETING RM 204 REC 0.90 20 1 27 B 28 1 20 0.72 REC FURNITURE • CENTRAL OPEN OFFICE REC -IT CLOSET 226 REC 0.72 20 1 29 C 30 1 20 SPARE REC - IT CLOSET 226 REC 0.72 20 1 31 A 32 3 100 8.74 COMB PANEL PB2 REC -IT CLOSET 226 REC 0.72 20 1 33 B 34 - - 7.02 REC - SPARE 20 1 35 C 36 - - 8.90 COMB - FURNITURE -CLASSROOM B REC 0.90 20 1 37 A 38 3 40 1.16 REC PANEL PB3 FURNITURE -CLASSROOM B REC 0.90 20 1 39 B 40 - - 2.42 COMB - FURNITURE -CLASSROOM B REC 0.90 20 1 41 C 42 - - 3.02 COMB - ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED LIGHTING LTG 5.90 KVA 7.38 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE A: 17.62 KVA 146 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE B: 17.00 KVA 142 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) PHASE C: 18.76 KVA 156 AMPERES REMAINING MOTORS MTR 0.50 KVA 0.50 KVA (100%) GEN PURPOSE RECPT REC 44.48 KVA 27.24 KVA (50%> 10KVA) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) GENERAL NOTES: EQUIP/OTHER MISC 2.50 KVA 2.50 KVA (100%) 1 BOLD INDICATES NEW OR LOAD MODIFICATIONS. HEATING MISC 0.00 KVA 0.00 KVA (100%) ELEVATOR [0 Total] ELEV 0.00 KVA 0.00 KVA (100%) KITCHEN El [0 Total] KITCH 0.00 KVA 0.00 KVA (100%) TOTALS 53.38 KVA 37.62 KVA FLAG NOTES: 148 AMPS 104 AMPS 1 LOAD TYPE NOTES: "COMB"= COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT 100% PANEL SCHEDULE PANEL: PB2 LOCATION: ELECT ROOM LEVEL 2 VOLTS: 208 Y/12OV P: AIC RATING: <-SEE RISER DIAGRAM >000< NEUTRAL: 100% DISTRIBUTION: 3 W: 4 AMP: 100 MLO X MCB MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW ❑ STYLE: NO FED FROM: PANEL PBI CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION REC - ROOM 6222, 6216, 6223 REC 0.90 20 1 1 A B C A B C A B C A B C A B C A B C A B C 2 1 20 0.50 REC REC - ROOM 6216 REC - ROOM 6222 REC 0.40 20 1 3 4 1 20 0.40 REC REC - ROOM 6216 REC - ROOM 6216 (MAIL) REC 0.40 20 1 5 6 1 20 0.54 REC FURNITURE -NORTHEAST OPEN OFFICE COPIER ROOM 6216 REC - ROOM 6225 MISC REC 1.50 0.40 20 20 1 1 7 9 8 10 1 1 20 20 0.54 1.08 REC REC FURNITURE - NORTHEAST OPEN OFFICE FURNITURE (CONTROLLED).- NORTHEAST OPEN OFFICE PROJECTOR ROOM 6225 MISC 0.50 20 1 11 12 1 20 1.50 REC REC - ROOM 6224 SPARE 20 1 13 14 1 20 0.40 REC REC - ROOM 6224 COUNTER GFI SPARE 20 20 1 1 15 17 16 18 1 20 0.70 REC REC - ROOM 6224, 6225 SPARE 1 20 0.40 REC REC - ROOM 6210 REC - ROOM 6219, 6220, 6221 REC REC REC REC 0.90 0.40 0.20 0.70 20 20 1 1 1 1 19 21 23 25 20 1 20 0.54 REC REC REC REC FURNITURE -WEST OPEN OFFICE REC - ROOM 6221 22 24 26 1 1 1 20 20 20 1.08 0.54 0.72 FURNITURE (CONTROLLED) -WEST OPEN OFFICE REC - ROOM 6216 REC - ROOM 6217, 6218 20 20 FURNITURE -WEST OPEN OFFICE FURNITURE (CONTROLLED) -WEST OPEN OFFICE REC - ROOM 6217, 6218, 6219 REC 0.90 20 1 27 28 1 20 0.72 REC FURNITURE -WEST OPEN OFFICE REC - ROOM 6219, 6220, 6221 REC 0.70 20 20 1 1 29 31 30 1 20 SPARE SPARE 32 1 20 0.40 REC REC - ROOM, UC LIGHTING ROOM 6224 SPARE 20 1 33 34 1 20 0.40 REC REC - ROOM 6206, 6208 HALLWAY 6215 TRACK LIGHTING LTG 1.10 20 1 35 36 1 20 1.80 REC REC - PLOTTER ROOM 6212 HALLWAY 6215 TRACK LIGHTING LTG 1.10 20 1 37 38 1 20 0.54 REC FURNITURE (CONTROLLED) - OPEN OFFICE 216 SPARE . 20 1 39 40 1 20 0.54 REC FURNITURE -OPEN OFFICE 216 ADA DOOR ACTUATOR - ENTRY 209 MISC 0.50 20 1 41 42 1 20 0.72 REC FURNITURE -OPEN OFFICE 218 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED CONNECTED PHASE LOADING LIGHTING LTG 2.20 KVA RESIDENT LTG/FECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 19.96 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP/OTHER MISC 2.50 KVA HEATING MISC 0.00 KVA ELEVATOR [0 Total] ELEV 0.00 KVA KITCHEN El [0 Total] KITCH 0.00 KVA TOTALS 24.66 KVA 68 AMPS LOAD TYPE NOTES: 2.75 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA (100/35/25%) 0.00 KVA (125%) 0.00 KVA (100%) 14.98 KVA (50%> 1OKVA) 0.00 KVA (100%) 2.50 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 0.00 KVA (100%) 20.23 KVA 56 AMPS LOAD TAKEN AT INDICATED DEMAND CIRCUIT AT 100% PHASE A: 8.74 KVA 72 AMPERES PHASE B: 7.02 KVA 58 AMPERES PHASE C: 8.90 KVA 75 AMPERES GENERAL NOTES: LOAD MODIFICATIONS. 1 BOLD INDICATES FLAG NOTES: NEW OR 1 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED PANEL PB3 PANEL PB1 - PANEL PB2 p r7 0201 FR RATE APPROVAL REQUIRED PERMIT SET - JULY 21, 2017 Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (206)223-6446 Seallle, Washington 98104 fax (206)2236465 EXPIRES I-17-18 ISSUE / REVISIONS ID (;', DE .:-.;C:.-',1,..1i,"1-1(1)1\1 CITY OF UKWiL p JUL 2821017 PRRMir CENTER Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES (3) E6.3