Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0270 - ALZHEIMER'S ASSOCATION - WALL DEMOLITION, NEW PARTITIONS, DOORS, RELITES ETC
ALZHEIMER'S ASSOCIATION 635 ANDOVER PARK W 200 D17-0270 Parcel No: Address: Project Name: C City of Tukwila C Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049143 635 ANDOVER PARK W 200 ALZHEIMER'S ASSOCATION Permit Number: D17-0270 Issue Date: 11/13/2017 Permit Expires On: 5/12/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOUTHCENTER CORPORATE SQUAR 635 ANDOVER PARK W #107 , TUKWILA, WA, 98188 CHELSEA GASKILL 635 ANDOVER PARK W STE 107 , TUKWILA, WA, 98188 DAVIS SCHUELLER INC 4601 CHENNAULT BEACH RD - SUITE 200 , MUKILTEO, WA, 98275 DAVISSI105PN SOUTHCENTER CORPORATE SQUARE LLC 635 ANDOVER PARK W STE 107 , TUKWILA, WA, 98188 Phone: (206) 575-3080 Phone: (206) 775-9400 Expiration Date: 7/1/2018 DESCRIPTION OF WORK: WALL DEMO, NEW PARTITIONS, DOORS, RELITES, CASEWORK AND CARPET/PAINT Project Valuation: $70,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $2,077.01 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: IV/ Date: Y� h I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: / (j. -131-4-e-1./1/ Date: /j /45// 7 Print Name: c_/eciey �/ rev7� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 'O O 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 9: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 13: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 17: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 18: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 21: ***BUILDING PERMIT CONDITIONS*** 22: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 23: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 0 24: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 25: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 26: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 27: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 28: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 29: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 30: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 31: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 32: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 33: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 34: ***BUILDING PERMIT CONDITIONS*** 35: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 36: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 37: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 38: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 39: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 40: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 41: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 42: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 43: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 44: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 45: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 46: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 121141 0 Project No. �Date Application Accepted: I 60 I1 Date Application Expires: I (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 635 Andover Park West Tenant Name: Alzheimer's Association PROPERTY OWNER Name: Southcenter Corporate Square, LLC Address: 635 Andover Park West Suite 107 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Chelsea Gaskill Address: 635 Andover Park West Suite 107 City: Tukwila State: WA Zip: 98188 Phone: (206) 575-3080 Fax: Email: cgaskill@pinnacle-commercial.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Company Name: N/A Architect Name: Linda Ducey City: State: City: Seattle State: WA Zip: Phone: Fax: Email: lducey@nelsononline.com State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:WpplicationsWorms-Applications On Line\201 I Applications\Pennit Application Revised - 8-9-I l.doca Revised: August 2011 bh King Co Assessor's Tax No.: 51-0599163 Suite Number: 202 Floor: 2 New Tenant: 0 Yes ID ..No ARCHITECT OF RECORD Name: Southcenter Corporate Square LLC Company Name: Nelson Company Name: N/A Architect Name: Linda Ducey Address: 821 2nd Ave #410 City: Seattle State: WA Zip: 98104 Phone: (206) 441-1449 Fax: Email: lducey@nelsononline.com State: ENGINEER OF RECORD Name: Southcenter Corporate Square LLC Address: 635 Andover Park West Suite 107 Company Name: N/A Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Southcenter Corporate Square LLC Address: 635 Andover Park West Suite 107 City: Tukwila State: WA Zip: 98188 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 70,000 Describe the scope of work (please provide detailed information): Wall demo, new partitions, doors, relites, casework and carpet/paint. Will there be new rack storage? ❑ Yes Existing Building Valuation: $ ®.. No If yes, a separate permit and plansubmittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ] No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplieationsWorms-Applications On Line \ 201Applications\Pemut Application Revised - 8-9-I l.doca Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor 10,679 2°d Floor 10,679 2,484 3"1 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ] No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplieationsWorms-Applications On Line \ 201Applications\Pemut Application Revised - 8-9-I l.doca Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ® ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District 0 ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut 0 .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size 33 WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State . Zip H:\ApplicationsWorms-Applications On Line12011 ApplicationssPermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: eM 11 Print Name: � � �CI..0 rt3 ' 1 Day Telephone: Of, Mailing Address: l G'(i 4 U !Dv )J6,4 & 1 b State ` Zip H:Wpplications\Forms-Applications On Line\201I Applications\Pennit Application Revised - 8-9-1I.docz Revised: August 2011 bh City Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $4,245.90 D17-0269 Address: 575 ANDOVER PARK W 210 Apn: 2623049144. " $2;168.89 . DEVELOPMENT $2,105.23 PERMIT FEE R000.322.100.00.00 0.00 $1,273.17 PLAN CHECK FEE R000.345.830.00.00 0.00 $827.56 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $63.66 TECHNOLOGY FEE R000.322.900.04.00 0.00 $63.66 D17-0270 Address: 635 ANDOVER PARK W 200 Apn: 2623049143 $2,077.01 DEVELOPMENT $2,016.05 PERMIT FEE R000.322.100.00.00 0.00 $1,219.12 PLAN CHECK FEE R000.345.830.00.00 0.00 $792.43 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $60.96 TECHNOLOGY FEE R000.322.900.04.00 0.00 $60.96 TOTAL FEES PAID BY RECEIPT: R12484 $4,245.90 Date Paid: Wednesday, October 04, 2017 Paid By: SOUTHCENTER CORP SQUARE Pay Method: CHECK 7689 Printed: Wednesday, October 04, 2017 12:01 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1 17-O27Q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ` h142/7/47/We 5- hi>76, ' Type of Inspection: 1.. - la 0iLOIN& F1141.._ Address: Address: 635 RruDf � RIWK Date Called: Special Instructions: ,-CO Date Wanted: 1�-20--17 a.m. p.tfi. Requester: Phone No: 2 'Q 730 0 l ?4 / Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6i<- 13ttLPPNG- 1; Inspector: �-S Date: a73-1/7 REINSPECTION REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A,2 nAR ,- So Type of Inspection: 51)5P,6 -714 „P d`!UNG- Address: 635- ANDOV..R PAM< 1/3, Date Called: Special Instructions: ,./00 Date Wanted: /2 --//-/7 P.m - Requester: Phone No: 76d2 -73D --i4?/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: a k — Cd AR 4,2 Inspector: Date: 2/C 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D17- 69:0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Az/-1-0//fl2'R s A.3S',, Type of Inspection: 5 pA)42.4710 ee/ LING - Address: ' 635- AigibblAW X191 kJ) Date Called: ail ss 1)\16- -_ Special Instructions: Q Date Wanted: 12- —7-17 �.m, p.m. Requester: 6".. Phone No: 2O -7Yib - 13( ) Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1' )1,4)5si/G- CLi/S oN RAILS pad 0 SfDtc ail ss 1)\16- 3RH-eNG Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DI7-c'2 7O Project: / lift_Vii'/ ks-A s 46-61), Type of Inspection: FAA -m i xl6- Address: 635- / vizi,i Myek W Date Called: Special Instructions: 4 m L ei5✓4rz r1 -/v -- /2,2714 Date Wanted: Ca.m Requester: -.ii-:AG- Phone No: zr-)(-710 - / 3W Approved per applicable codes. El Corrections required prior to approval.. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit o 2-7o /7T 5- `01 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /2 '7A4eg C /hSo c Type of Inspection: 1/A t--; 4 / Address: 'Contact Suite #: (02c /4-79 w Person: Special Instructions: Phone No.: • Approved per applicable codes. Corrections required prior to. approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: 'Occupancy Type: -- fic-e Awoke/ Y A/c''' r UIce-,i -- MSS /c'ss -- ---- iA/4- / — PASS kr-77X- - %/ 'S /A'5v e c--71 o— Needs Shift Inspection: , Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: 'Occupancy Type: Inspector: s"5 Date: /Z/Zv/'i Hrs.: 4' 0 i 'I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ji1--d2) PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A/ .0-4 / ma v c /be- Type of Inspection: . . i/J2-1---- Address: Suite #: %.3-c 40,0 Ak ZoZ Contact Person: Special Instructions: Corrections required prior to approval. r Phone No.: a; Needs Shift/Inspection: Approved per applicablecodes. Hood & Duct: Monitor: Pre -Fire: Corrections required prior to approval. r Occupancy Type: COMMENTS: ie- ,vp or ---/4,- 4,j /3 -&---ict-b c I .r Needs Shift/Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A(C- Date: /7,4,--7/ 7 Hrs.: % 0 $100..00 REINSPECTION FEE REQUIRED. You ill receive an invoice from the City of Tukwila'Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 October 25, 2017 City of Tukwila Department of Community Development CHELSEA GASKILL 635 ANDOVER PARK W STE 107 TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0270 ALZHEIMER'S ASSOCATION - 635 ANDOVER PARK W 200 Dear CHELSEA GASKILL, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. The architect stamp appears to be an old copied stamp. Provide architectural stamp, signature and date of that signature on each sheet. All documents created by a design professional shall be provide with current stamp and dated signatures. See General note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can behed at (206)433-7165. Sincerely, achelle Ripley Permit Technician File No. D17-0270 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 oPERM6T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0270 DATE: 10/27/17 PROJECT NAME: ALZMEIMERS ASSOCIATION SITE ADDRESS: 635 ANDOVER PARK W SUITE 200 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kWC 11-1-17 Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator CI PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/31/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/28/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0270 DATE: 10/09/17 PROJECT NAME: ALZHEIMER'S ASSOCIATION SITE ADDRESS: 635 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT C014-- tO—w 1 _I Building Division P1-tOr7 Public Works m\ivb'1�11 1-M "% 1010--r 7 Fire Prevention Division Structural ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/10/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 11/07/17 ❑ Approved with Conditions (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping 0 PW ❑ Staff Initials: 164' 12/18/2013 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /b/.1 / Plan Check/Permit Number: 111 0 c9-1 I l ❑ Response to Incomplete Letter # Response to Correction Letter # -❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: AIZkb►M(Ars V (kLUm Project Address: t.035Airvioycy 2 L . 2-0( Contact Person: jeCA-in(V 1 Phone Number:o76 (o - 02-7 e- `f7'�775 Summary of Revision: pyintiOub 8 famy e5drahAt_ LLA/LA olLar - .Scrtejk-uL- RECEIVED CITY OF TUKWILA OCT 272011 PERMIT CENTch I Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision C Received at the City of Tukwila Permit Center by: ig.—.Entered in TRAKiT on tO W:\Permit Center \Templates\Forms\Revision Submittal Form.doc Revised: August 2015 DAVIS SCHUELLER INC C Washington State Department of Labor & Industries 0 Home Espanol Contact Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z Index Workplace Rights DAVIS SCHUELLER INC Owner or tradesperson Principals SCHUELLER, KENNETH E, PRESIDENT STOCKBURGER, JAMES A, VICE PRESIDENT SCHUELLER, DANETTE, SECRETARY SCHUELLER, KENNETH E, TREASURER DAVIS, BILL E, PRESIDENT (End: 06/26/2014) SCHUELLER, KENNETH E, VICE PRESIDENT (End: 06/26/2014) DAVIS, BARBARA D, TREASURER (End: 06/26/2014) Doing business as DAVIS SCHUELLER INC WA UBI No. 601 273 797 4601 Chennault Beach Rd Suite 200 MUKILTEO, WA 98275 425-775-9400 SNOHOMISH County Business type Corporation Governing persons BARBARA DAVIS BILL E DAVIS; KEN SCHUELLER; DANNETTE SCHULLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSI105PN&SAW= 11/13/2017 DAVIS SCHUELLER INC License specialties GENERAL License no. DAVISSI105PN Effective — expiration 10/15/1990— 07/01/2018 Bond CBIC Bond account no. SF2518 Active. (� Meets current requirements. $12,000.00 Received by L&I Effective date 10/31/2003 10/15/2003 Expiration date Until Canceled Insurance BITCO National Ins Co $1,000,000.00 Policy no. CLP3655384 Received by L&I Effective date 06/21/2017 07/01/2017 Expiration date 07/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 3 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 588,421-00 Doing business as DAVIS SCHUELLER INC Estimated workers reported Quarter 3 of Year 2017 "51 to 75 Workers" L&I account contact T1 / DESTINY ADAMS (360)902-4873 - Email: ADAF235@Ini.wa.gov Public Works Strikes and Debarments https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSI105PN&SAW= 11/13/2017 Help us imfrove DAVIS SCHUELLER INC Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Page 3 of 3 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 11/10/2015 Inspection no. 317938271 Location 3600 15th avenue Seattle, WA 98114 Violations Inspection results date 04/02/2014 Inspection no. 316973973 Location 12856 Gateway Dr Tukwila, WA 98168 Violations © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSI105PN&SAW= 11/13/2017 Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 7 2017 /k". City of Tukwila BUILDING DIVISION .2.. •TM Consultant: Description: No: By: Date: REVISION 11\ MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: COVER SHEET Sheet Title: SCOPE OF WORK A ZOCCUPANCY 8459 !Mils SIAII. 1W qk Seal: Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD . Designer: EB Reviewed By: LD Approved By: ME, LD TI -i T4 Rs Assoc ATIoN TENANT IMPROVEMENT OF AN EXISTING OFFICE SUITE ON THE SECOND FLOOR OF BUILDING 8 IN A 11 BUILDING CAMPUS TO INCLUDE: • CONSTRUCTION OF NEW INTERIOR SUITE PARTITIONS, DOORS, RELITES, AND CASEWORK • NO WORK TO THE CORE AND SHELL OF THE BUILDING AREA OF SUITE: ± 2,484 SQ.FT. AREA OF WORK: ± 2,484 SQ. FT. AREA OF FLOOR: ± 10,679 SQ. FT. TYPE: GROUP B, OFFICE CONSTRUCTION TYPE: V -B, SPRINKLERED ASSESSOR'S PARCEL #: 262304-9143 LEGAL DESCRIPTION 0 1 C NANT MPROV M N LOT 3 OF CITY OF TUKWILA SHORT PLAT NO L97-0049 RECORDING NO 9711069009 SAID SHORT PLAT DEFINED - PORTION OF E 1/2 OF NW 1/4 OF SE 1/4, BEGIN NE CORNER OF SAID E 1/2 BEING N 88-05-42 W 1339.34 FT FROM NE CORNER OF SE 1/4 TH S 01-47-29 W 1322.34 FT souTHcENTER 635 U coRpoRATE ANDOVER PARK 3 ASHINGTON SQUARE ..... BUILD EST 98188 NG 8 SEPARATEPERMIT REQUIRED FOR: r-�O���nj�� 4iJ Electrical UrPtumbing Was Piping City of Tukwila E3UILDING DIVISION TO SOUTHEAST CORNER TH N 87-55-02 W 659.35 FT TOW LINE OF E 659.34' FT OF SAID E 1/2 TH N 01-47-29 E 1320.30 FT TO N LINE OF SAID E 1/2 TH S 88-05-42 E 659.34 FT TO POB LESS PORTION FOR 59TH AVE SOUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120770 LESS PORTION CONVEYED TO CITY OF TUKWILA FOR ROAD BY DEED, RECORDING NO 9408290327 APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 UNIFORM PLUMBING CODE (UPC 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2014 NATIONAL ELECTRICAL CODE 2009 ACCESSIBLE & USABLE BUILDING & FACILITIES (ICC/ANSI A117.1) ICC/ANSI 117.1 -ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51-11 WASHINGTON INDOOR AIR QUALITY CODE PROJECT DIRECTORY TENANT CONTRACTOR REVISImNS ALZHEIMER'S ASSOCIATION TBD BUILDING REPRESENTATIVE ARCHITECT No Changes shall be made to the SCo of work without prior approval of Tukwila Building Division. NOTE: Revisions will require ra new plan submitiaf and may include additional plan review fees. PINNACLE FAMILY OF COMPANIES NELSON 720 THIRD AVE, SUITE 1605 1200 FIFTH AVE. #13000 SEATTLE, WASHINGTON 98104 SEATTLE, WASHINGTON 98101 CONTACT: TAMARA MALONEY CONTACT: LINDA DUCEY EMAIL: tmaloney@pinnaclecommericial.com TELEPHONE: (206) 408-8500 EMAIL: LDucey@nelsononline.com PROJECT TITLE NA 2 PROJECT. INFORMATION NA 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION SHALL BE PROVIDED UNDER SEPARATE PERMITS / BY DESIGN BUILD CONTRACTORS. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO BUILDING REPRESENTATIVE. VERIFY LOCATION OF THERMOSTATS WITH TENANT OR ARCHITECT PRIOR TO FINAL INSTALLATION.PI'3 ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE BUILDING. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM BUILDING REPRESENTATIVE. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL & AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED 'A" & SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL & SEALED WITH METAL= ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY APPLIED FIRE PROOFING. ' , •� Q Q. '_405 STRAN Ari a R BLVD. 4 2 1. COMPLY WITH ALL APPLICABLE CODES. I 10 2 2. THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY THE FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO ARCHITECT BEFORE PROCEEDING WITH THE WORK. Lu 0 (1:1/ 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. Q 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. } in ¢ p Q BUILDINGS fi 5Et j6. PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. a a � w r...CITC MINK R E LVD. I C ■ 0 7. THE BUILDING REPRESENTATIVE SHALL ESTABLISH 9 7 6 Z d WORKING TIME AND STANDARDS OF CONDUCT. 8. DO NOT SCALE DRAWINGS. 9. GENERAL CONTRACTOR SHALL COORDINATE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND STAGING OF MATERIALS. v UPLAND D . 0 \ 0 co MIDLAND D'. CORRE .TION \ TRILAND D . LTR# NORTH MINKLER BLVD. NORTH 3 MECHANICAL, PLUMBING, FIRE PROTECTION & LIFE SAFETY NOTES NA 4 VICINITY MAP NTS 5 SITE PLAN NA 6 GENERAL NOTES NA ACT ACOUSTICAL CEILING TILE ELEC'L ELECTRICAL LF LINEAL FOOT REINF REINFORCING ADJ ADJACENT/ADJUSTABLE ELEV ELEVATION (VIEW) MAX MAXIMUM REQ'D REQUIRED AFF ABOVE FINISH FLOOR EQ EQUAL MECH MECHANICAL REV REVISION / REVERSE ALT ALTERNATE EXIST EXISTING MFR MANUFACTURER RM ROOM ALUM ALUMINUM EXT EXTERIOR MIN MINIMUM RO ROUGH OPENING APPROX APPROXIMATELY FIN FINISH MISC MISCELLANEOUS S SOUTH @ AT FLR FLOOR MTD MOUNTED SCHED SCHEDULE BLDG BUILDING FLUOR FLUORESCENT MTL METAL SC SOLID CORE BLKG BLOCKING FMC FLOOR MATERIAL CHANGE MW MICROWAVE OVEN SECT SECTION B/S BUILDING STANDARD FR FIRE RATED N NORTH 1 NEW SIM SIMILAR CAB CABINET FT FEET N/A NOT APPLICABLE SPEC SPECIFICATION CLR CLEAR/CLEARANCE FURN FURNISH/FURNISHINGS NIC NOT IN CONTRACT SQ SQUARE CLG CEILING GA GAUGE NO NUMBER STD STANDARD CL CENTERLINE GALV GALVANIZED NOM NOMINAL STL STEEL COL COLUMN GD GARBAGE DISPOSAL NTS NOTTOSCALE STOR STORAGE COMM COMMUNICATION GL GLASS / GLAZING OC ON CENTER SUSP SUSPENDED COMP COMPOSITION GWB GYPSUM WALL BOARD OPNG OPENING TEL TELEPHONE CONST CONSTRUCTION HC HOLLOW CORE OPP OPPOSITE TSG TEMPERED SAFETY GLASS CONT CONTINUOUS HDW HARDWARE ORIG ORIGINAL TYP TYPICAL CPT CARPET HM HOLLOW METAL PERM PERMANENT UNO UNLESS NOTED OTHERWISE CERAMIC/CONCRETE TILE HT HEIGHT PL PLATE VCT VINYL COMPOSITE TILE DIA DIAMETER HVAC HEATING, VENTILATING, PLAM PLASTIC LAMINATE VERT VERTICAL DR DOOR AIR CONDITIONING PLYWD PLYWOOD W WEST DIM DIMENSION IN INCH PR PAIR W/ WITH DW DISHWASHER INCL INCLUDE PTN PARTITION W/O WITHOUT DWG DRAWING INSUL INSULATION R RADIUS / REMOVE ! RELOCATE WC WALLCOVERING E EXISTING / EAST INT INTERIOR RB RUBBER BASE WD WOOD EA EACH JT JOINT REF REFRIGERATOR EAD EXIT ACCESS DOOR LL@TE BY LANDLORD AT TENANT'S REFL'D REFLECTED ELEC ELECTRIC EXPENSE I . ` ©��� Planrornofaovaliscu toarroraance. Relonn. of ConstrUCtion documents dose not authoriz�lCT :PI:I:rationof any adopted COdB or ordinance. Receip# of approved X191$ Copy and conditions it acknowledged; By.im.. ,, f _, Date: Mr/ 3 I City of Tuna �7 BUILDING DIVISION RECEIVED TI -1 COVER SHEET CITY OF TUKWILA OCT 27 2017 TI -2 LIFE SAFETY PLAN PERMIT CENTER - Q TI -3 DEMOLITION CONSTRUCTION & G BVI V L I V , I� REFLECTED CEILING PLANS TI -4 DOOR & RELITE SCHEDULE & DETAILS 7 ABBREVIATIONS NA 8 NOT USED NA 9 NOT USED NA 1 0 SHEET INDEX NA Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 7 2017 /k". City of Tukwila BUILDING DIVISION .2.. •TM Consultant: Description: No: By: Date: REVISION 11\ MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: COVER SHEET Sheet Title: fi l I Rl•:n r• WASIIINWON • q*". - 8459 !Mils SIAII. 1W qk Seal: Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD . Designer: EB Reviewed By: LD Approved By: ME, LD TI -i ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED Plot Date: 10/26/2017 5:37:07 PM Filename: J:\BLDGS\S-z\SouthcenterCorpSquare\Building 8 (635 Andover)\Alzheimer - 02\Working Drawings\Permit Set\(TI-2) SCS_AA-LAS-02.dwg User: Maria Sainciuc Device: None PenTable: _NELSON-FULL.ctb SOUTHCENTER CORPORATE SQUARE BUILDING 8 EXISTING TWO (2) STORY OFFICE BUILDING EXIT ACCESS STAIR LONGEST COMMON PATH OF EGRESS TRAVEL TRAVEL DISTANCE = ± 108' TO GROUND FLOOR EXIT DOOR 2ND FLOOR LIFE SAFETY PLAN 1/8" =1'-0" 0 5' 10' 20' EXCLUSIONS NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE OF USE 30' OCCUPANT LOAD & EXITING PER IBC TABLE 1004.1.2: BUSINESS AREAS =100 SF PER OCCUPANT PER IBC TABLE 1015.1: 0-49 OCCUPANT LOAD = ONE (1) EXIT REQUIRED BUSINESS AREA (OFFICE): ± 2,484 SF @ 1:100 = 25 OCCUPANTS 1 EXIT REQUIRED, 2 EXITS PROVIDED COMMON PATH OF EGRESS TRAVEL PER IBC 1006.2.1: FOR GROUP B OCCUPANCY, MAX. LENGTH = 100'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM ACTUAL MAXIMUM COMMON PATH LENGTH = ± 36' PROJECT COMPLIES EXIT ACCESS TRAVEL DISTANCE PER IBC TABLE 1017.2: FOR GROUP B OCCUPANCY, MAX. TRAVEL DISTANCE = 300'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM ACTUAL TRAVEL DISTANCE _ ± 108' PROJECT COMPLIES NORTH REVIEWED FOR CODE COMPLIANCE APPROVED NOV 072017 City of Tukwila BUADING DIVISION RECEIVED CITY OF TUKWILA OCT 27 2017 PERMIT CENTER Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: REVISION 11Q MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: LIFE SAFETY PLAN Sheet Title: 0 ... — RI (GIS I I:I 8459 M •KDOU ,,• ,:- ,, • SIAIL 01'N.VSIIJN(IION £1 Seal: Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD Designer: EB Reviewed By: LD Approved By: ME, LD TI -2 ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTO: ' ND SUB -CONTRACTORS PRIOR TO ERFO G THE . TH j � MANAGER SHALL BE NOTIFIED IN AN (3 s„ TO PROCEEDING WITH THE WORK. ON W ; DW , j g; 17 ALL RIGHTS RESERVED Plot Date: 10/26/2017 5:38:28 PM Filename: J:\BLDGS\S-z\SouthcenterCorpSquare\Building 8 (635 Andover)\Alzheimer - 02\Working Drawings\Permit Set\(n-3) SCS_AA-DE_PL-02.dwg User: Maria Sainciuc Device: None PenTable: _NELSON-FULL.ctb DN PTN./ MUL. PIN./ MUL. $ PTN./ MUL. o P PTN./ MUL. z i ,'/ / / 7' %/i /, //// j//�////'i ///:////// / ///.// // / / //,/</,/, 'i i • c / / // / / i/'//, / ///// • // ///////// // , / •// / //; // // 2/ //////:///:::;,/::/,/,://, /'/ ////,,",,,,/////,///1/1/--//////////1://,<'1:://// j /////i/,/i /'� /// //////////,// /////,////,,://'/,/4-,7//,///,`,•/',--i:// ,- / / // / . / / /'/ / r , /747 / , % Vii/'/;/ / / ///i/ // // ///`/////' '' / //,/ / /,///i / / , / / OFFICE 207 OFFICE 206 ( 207 ) • CO WORK ROOM 208 • 5' 0" 10'-6" to NDN 12'-0" OFFICE 205 OFFICE 204 OPEN WORK AREA 211 9'-0" ( 209 ) TELECOM 209 COMMON CORRIDOR O N +9,-5" IELD VERIFY F L;1 ,, —'i 11 11� BREAK ROOM 210 N N EQ. STORAGE 212B 2ND FLOOR DEMOLITION & CONSTRUCTION PLAN 1/8" =1'-0" 0 5' 10' 20' DN / 30' CONFERENCE 212A n O N (212A) zse 13'-5" OFFICE 203 CONFERENCE 202 ( 202 ) RECEPTION 201 NORTH / /,j'/ '/,, i i /'/• // 1/4////: / / i /, / //:/ / /// / // / !,/;://////// / ;/j/ / ;/ %�%//%/;' ice%; / 207 206 205 204 203 211 202 '/4////// / / / /''/ /////4//,',//7//2/ 208 2,,,,•00/,/°4%,//2/7/////°/,/,/;•../,:/,.////:/'///////:///////, ////::„/://1://////';'?<7;/////;////// ///// /, /j; // .L ,,,, /,„.././/,/,„; ////////////./.7/.///, ' / SR E 209 210 201 212B 212A )M COMMON CORRIDOR //, /j//% j // / /7/1. //M-7 2ND FLOOR REFLECTED CEILING PLAN 1/8" =1'-0" 0 5' 10' 20' 30' NORTH DEMOLITION & CONSTRUCTION LEGEND /4</i. EXISTING BUILDING SHELL AND CORE NOT TO BE ALTERED EXISTING B/S CORRIDOR PARTITION. EXISTING CONSTRUCTION TO BE DEMOLISHED NEW B/S PLAM CASEWORK NEW B/S TENANT INTERIOR PARTITION PER DETAIL 6/TI-6 NEW B/S SOUND PARTITION PER DETAIL 51TI-6. NEW B/S DEMISING PARTITION PER DETAIL 5/TI-6. EXISTING INTERIOR PARTITION TO BE UPGRADED TO DEMISING PARTITION PER DETAIL 5/TI-6. NEW DOOR PER SCHEDULE PER 3/TI-6 NEW B/S FULL HEIGHT RELITE PER 3/TI-6 SCHEDULE DEMOLITION & CONSTRUCTION NOTES DEMOLITION & CONSTRUCTION KEYNOTES: REMOVE EXISTING GRAB BAR, PATCH WALL AND PREP FOR NEW PAINT. EXISTING SUITE ENTRY DOOR TO REMAIN. SEE ADA COMPLIANT SINK DETAIL PER DETAIL 8/11-5 1. REMOVE EXISTING FLOORING AND WALL BASE AND PREP FOR NEW FLOORING AND WALL BASE THROUGHOUT UNO. 2. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION. 3. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND BUILDING REPRESENTATIVE. 4. ALL DEBRIS SHALL BE REMOVED FROM THE DEMOLITION SITE DAILY. 5. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 6. CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 7. CONTRACTOR SHALL NOTIFY BUILDING REPRESENTATIVE AND ARCHITECT OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 8. GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO BUILDING REPRESENTATIVE. CEILING LEGEND SR 40 EXISTING CEILING GRID AND TILES TO REMAIN NEW B/S 25(4' RECESSED FLUORESCENT LIGHT FIXTURE (SR = SALVAGED/RELOCATED) NEW B/S 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY NEW B/S ILLUMINATED EXIT SIGN. DIRECTIONAL WHERE SHOWN. (3) (M) NEW B/S LIGHT SWITCH (3 = THREE WAY, M = MASTER) LIGHTING CALCULATION SYMBOL USED WATTS/FIXTURE # OF FIXTURES TOTAL WATTS »., 8459 Al MRK DOUGLAS' S1'A 11, 01WASIIIN(110N Seal: 60 4 240 Pill 60 20 1,200 TOTAL: 1,440 WATTS PROPOSED 2,484 TOTAL SF x .66 WATTS PER SF =1,639 ALLOWABLE WATTS. TOTAL PROPOSED WATTAGE IS 1,440 - WHICH IS LESS THAN THE ALLOWABLE WATTAGE PER 2015 WSEC INTERIOR LIGHTING POWER C405.4.2 (TABLE C405.4.2(1) BUILDING AREA METHOD). PROJECT COMPLIES. 9. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 10. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 11. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO ARCHITECT. 12. ALL EXISTING WINDOW COVERINGS TO BE CLEANED AND IN GOOD WORKING ORDER. CEILING NOTES 1. REMOVE ALL EXISTING ACRYLIC LENS 2X4 LIGHT FIXTURES. FOUR (4) EXISTING NEW B/S 2X4 LIGHT FIXTURES TO BE SALVAGED AND RELOCATED. 2. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY ARCHITECT OF ANY CONFLICT(S). 3. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 4. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 5. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 6. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 7. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 8. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 9. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 272017 PERMIT CENTER Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: REVISION 1 MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: DEMOLITION, CONSTRUCTION & REFLECTED CEILING PLANS Sheet Title: 0 1) IIII.CI ' ' , »., 8459 Al MRK DOUGLAS' S1'A 11, 01WASIIIN(110N Seal: Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD Designer: EB Reviewed By: LD Approved By: ME, LD TI -3 ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN G OF ANY DISCREPANCIES PR ,', •ROCEEDING WITH THE WORK. L RIGHTS RESERVED Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: REVISION 1 10 MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: DOOR & RELITE SCHEDULE & DETAILS Sheet Title: DOOR AND FRAME SCHEDULE DOOR & FRAME GENERAL NOTES: Seal: 8459 RlilJtil.. : ...__.._..__ .c I . 40.4-11 ARKD.0 �, .:.._>. . • S I:VIl. 01 R'ASI II\'(i I ON ��1\- Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD Designer: EB Reviewed By: LD Approved By: ME, LD DOOR FRAME HARDWARE SIZE 1. UNDERCUT THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR, BY 1/2" INCH ROOM NO. WIDTH HT. TH. TYPE MATERIAL FINISH TYPE MATERIAL FINISH TYPE FINISH NOTES MAXIMUM, U.N.O. VERIFY SLAB CONDITIONS AND TRIM EACH DOOR TO FIT CONDITION. WHERE RADICAL VARIATIONS IN FLOOR LEVEL EXIST, DOORS SHALL BE CONFERENCE 202 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT R-1 MATCH B/S B/S A MATCH B/S ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE THESE UNDERCUT CONDITIONS. OFFICE 203 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT R-2 MATCH B/S B/S B MATCH B/S OFFICE 204 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT R-1 MATCH B/S B/S B MATCH B/S 2. AT HOLLOW METAL AND ALUMINUM FRAMES, CAULK THE JOINT BETWEEN THE FRAME AND WALL, ALL OFFICE 205 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT R-2 MATCH B/S B/S B MATCH B/S SIDES, WITH PRINTABLE WHITE LATEX CAULK. OFFICE 206 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT R-1 MATCH B/S B/S B MATCH B/S 3. CONTRACTOR OFFICE 207 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT FR -1 MATCH B/S B/S B MATCH B/S SHALL REVIEW KEYING WITH CLIENT PRIOR TO FITTING CYLINDERS. KEY CYLINDERS TO OWNER'S MASTER. TELECOM 209 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT FR -1 MATCH B/S B/S B MATCH B/S BREAK ROOM 210 3' - 0" 8' - 0" /, " - SC PT FR -1 MATCH B/S S C MATCH : A 4. ALL NEW DOOR HARDWARE TO MATCH BUILDING STANDARD MANUFACTURER, STYLE & FINISH. CONFERENCE v ✓ .w Z.f ✓w 3Y0C W 1 3/4" DR -2 SC PT FR -1 MYTCIYB/ B/S A MATCH B/S CONTRACTOR TO VERIFY BUILDING STANDARD WITH BUILDING REPRESENTATIVE. STORAGE 211L2A8 3' - 0" 8' - 0" 1 3/4" DR -1 SC PT FR -1 MATCH B/S B/S A MATCH B/S 5. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 6. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 15.0 , POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 7. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED B/S B/63'-0' 3'-0' THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH ,i,f f f f 1,j' 1 A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL I (50 -PERCENT SLOPE). `, HARDWARE TYPES: / \ \ / / / 0 CoCoCo / / \ \ . \ CocA / / / N \\/ . — , / TYPE A = B/S LATCHSET TYPE B = B/S LOCKSET TYPE C = B/S LOCKSET & CLOSER ABBREVIATIONS: / \N \ LA LAMINATE \ \ = SC = SOLID CORE WOOD DOOR TYPE: (DR -1) DOOR TYPE: (DR -1) DOOR TYPE: (DR -1) DOOR TYPE: (DR -2) PT = PAINT RELITE/FRAME TYPE: R-1 RELITE/FRAME TYPE: R•2 FRAME TYPE: (FR -1) FRAME TYPE: (FR -1) B/S = BUILDING STANDARD 1 NOT USED 2 DOOR & RELITE SCHEDULE & NOTES 1/4=1'-0" 25" , INSULATION 4'-0" WIDE ACOUSTIC BATT CENTERED OVER PARTITION ABOVE HUNG CEILING. SEISMIC BRACING 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN SEISMIC BRACING (BEYOND) PER 6/TI-4. // / / / 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN (BEYOND) PER 6/TI-4. ' / 1/8" BLACK FOAM TAPE, HOLD RUNNERS.,' , 1/8" BLACK FOAM TAPE, HOLD RUNNERS. // 1 1 till ' BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) // ,' BACK 1/4" FROM EDGE OF TRACK < ,' (BOTH SIDES) CEILING @+X'-X"A.F.F.111,.., 1Sti ! CEILING @+X -X" A.F.F. A.(, v, 1n � „7-ir7, lkIv � REVIEWED FORREFLECTED (WHERE INDICATED ON METAL TRACK WITH (2) #10 IV (WHERE INDICATED ON / �— METAL TRACK WITH (2) #10 CODE COMPLIANCE CEILING PLAN). SCREWS AT 16" O.C. REFLECTED CEILING PLAN). SCREWS AT 16" O.C. ): APPROVED ) CONTINUOUS '12 METAL < <) ` CONTINUOUS'L' METAL REVEAL(PAINT BLACK)OR EXISTING t 07 � 1 Nov TRIM WI PAPER WING (60TH REVEAL (PAINT BLACK) OR TRIM WI PAPER WING (BOTH MATCH EXISTING CONDITION. SIDES OF PARTITION) MATCH EXISTING CONDITION. STRUCTURE SIDES OF PARTITION) SIDES OF PARTITION) (BOTH SIDES OF PARTITION) 24 (BOTH � METAL CLIP �4 p Tukwila ACOUSTIC BATT INSULATION . �) Bu6Lti DIVISION 5/8" FIRE RETARDANT TREATED 518" FIRE RETARDANT TREATED METAL STUDS STAGGERED @ 8' 0" B/S S.S. FAUCET & PLYWOOD BLOCKING AT WALL HUNG ITEMS PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' 0". ATTACH 314" PLAM 3/4 PLA SINK PER ANSI 117.1 LASH. CODE COMPLIANCE C__— (WHERE APPLICABLE- REFER TO ✓ APPLICABLE- REFER TO TO STRUCTURE ABOVE. #10 SCREWS DRAWING PLANS). DRAWING PLANS). (2) B/S PLAM PL -1 ta COUNTERTOP, PER SCHEDULE. /��/ ING: OTMETOALKAT CKING: J < r r I c r r i �. „c i t I r i i Irr�r ) 20"ALWIDE SHEEERNATE +40" 20"ALWIDE SHEENATE TMETALAT +40" GALV. STEEL SILL TRACK. < ) FROM FLOOR TO BOTTOM GALV. STEEL SILL TRACK, `= FROM FLOOR TO BOTTOM (IN J� ATTACH TO STRUCTURE WITH < ) (IN ATTACH TO STRUCTURE WITH � HILTI X -U (OR XU15) UNIVERSAL ; L � --j LIEU OF WOOD BLOCKING) HILTI X -U (OR XU15) UNIVERSAL LIEU OF WOOD BLOCKING) SCHEDULED CEILING TILE &GRID B/S ADA- COMPLIANT KNURLED SHANK POWER DRIVEN �-- ) KNURLED SHANK POWER DRIVEN PROTECTIVE =1 CASEWORK COVERING AT EXPOSED HARDWARE ) FASTENER WITH MIN. 1" FASTENER WITH MIN. 1" 518" GWB, TYPE X' EACH SIDE 'I' EMBEDMENT @ 16" O.C. �� 518 GWB, TYPE X' EACH SIDE EMBEDMENT @ 16" O.C. PIPES. �C (FOLLOW MANUFACTURER'S ) (FOLLOW MANUFACTURER'S �� f INSTRUCTIONS). < j : BASE, AS SCHEDULED. INSTRUCTIONS). BASE, AS SCHEDULED. , MAX MAX MAX MAX ,g MAX MAX MAX • 1/4" PLYWOOD (BOTH SIDES OF PARTITION.) / (BOTH SIDES OF PARTITION.) — /� % / ' /� —7 TO END NOTES: <<---- ) 1 I 1. LATERAL BRACING IS TO BE INSTALLED ON CONCEALED FLOORING AS SCHEDULED < ) :,; FLOORING AS SCHEDULED OF WALL TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT BACKING (2) WITH C—] HINGES PER (BOTH SIDES OF PARTITION) EXISTING STRUCTURE (BELOW) (BOTH SIDES OF PARTITION) EXISTING STRUCTURE (BELOW) in OMIT BRACING AT WALL ----1' INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) MELAMINE � EACH DOOR. � ��/// '// //// LATERAL BRACING (STAGGERED) PER TOP OF WALL FINISH.ninu CABINET DOORS. jj j j / DETAIL ABOVE // —• (TYP.) LATERAL WALL BRACING PLAN VIEW 2 PROVIDE BRACING AT ANY PERMANENT PARTITION THAT ISNOT ATTACHED TO CEILING DASHED LINES � INDICATE REQUIRED _ 6"MIN.CLR• 8"MIN.CLR. P LAM FINISH ON EXPOSED FACE � EDGEWITH BATCHING ANDING � 2 NTS GRID. STUD SCHEDULE STUD SCHEDULE ACCESSIBLE CLEARANCES. / AND MELAMINE N FINISH ON N STUD SCHEDULE: STUD SCHEDULE: INTERIOR FACE. 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8 — 3625125-27 (22 GA); MAX 13'-0" HIGH. 6"= 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES:V-6" 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. Op GALV STEEL STUD, PER STUD2-1IZ' SCHEDULE, WITH 518" TYPE'X' GWB EACH SIDE. = 2505125-27 (22 GA); MAXGALV ��SCHEDULE, —10-0 HIGH. 3 518 — 362S125 27 (22 GA); MAX 13'-0” HIGH. 6" =1670, 0S125 27 (22 GA}; MAX -6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. ill I./ STEEL STUD, PER STUD WITH 5/8" TYPE'X'RECEIVED GWB EACH SIDE. CITY OF TUKWILA ()(;, 27 201 PERMIT CENTER • CONTINUE„_ FINISH FLOOR BELOW SINK � I _= z RESILIENT BASE, PER ' I ��c SCHEDULE. / ATTACH BASE TO DOOR. CUT BASE SHORT FOR PROPER DOOR OPERATION. 3 ADA COMPLIANT SINK 11/2"=1'-0" 4 STANDARD TENANT SOUND PARTITION 3=1'-0" 5 STANDARD TENANT PARTITION 3"=1'-0" 6 • STANDARD HEAD BRACING N Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Ave. Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: REVISION 1 10 MS 10/27/2017 CONSTRUCTION SET EB 09/25/17 PERMIT SET EB 09/25/17 ALZHEIMER'S ASSOCIATION SUITE 202 Client: ALZHEIMER'S ASSOCIATION OFFICE 635 ANDOVER PARK WEST - BUILDING 8 TUKWILA, WASHINGTON 98188 Project Title & Address: DOOR & RELITE SCHEDULE & DETAILS Sheet Title: 0 Seal: 8459 RlilJtil.. : ...__.._..__ .c I . 40.4-11 ARKD.0 �, .:.._>. . • S I:VIl. 01 R'ASI II\'(i I ON ��1\- Proj. No: MS.01292.00 Drawn By: EB/MS Project Manager: LD Designer: EB Reviewed By: LD Approved By: ME, LD TI -4. ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPAN S PRIOR TO PROCEEDING WITH THE WORK. NE pr;3 LD 2017 ALL RIGHTS RESERVED