Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0272 - KEY BANK - REROOF
KEY BANK 275 ANDOVER PARK W EXPIRED 04/22/18 D17-0272 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 9202470010 275 ANDOVER PARK W Project Name: KEY BANK DEVELOPMENT PERMIT Permit Number: D17-0272 Issue Date: 10/24/2017 Permit Expires On: 4/22/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, OH, 92013 MICHAEL HACKEL PO BOX 92986 , CLEVELAND, OH, 44194 NW ROOFING SOLUTIONS LLC PO BOX 2478 , EVERETT, WA, 98213 NWROORS971M4 TRAVELER'S CASUALTY 1501 4TH AVE STE 1000 , SEATTLE, WA, 98101 Phone: (206) 241-9335 Phone: (425) 231-8273 Expiration Date: DESCRIPTION OF WORK: DEMO EXISTING ROOF SYSTEM, INSTALL NEW 1/4" GYPSUM BOARD, RIGID INSULATION, CRICKETS, EPDM ROOF MEMBRANE AND NEW PERIMETER METAL Project Valuation: $103,504.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $2,765.11 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know to same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: \/ i4 g ley Date: /Oil)! 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUIeILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building P _ it No. Project No. 1 'On Date Application Accepted: i 0 Date Application Expires: VI I 1, I For o ice use on CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assesssfo;1 s Tax No.: Site Address: 2:15 A n Ver Pa c iO1 c auf l- uite Number: Floor: New Tenant: ❑ Yes (0.. No Tenant Name: key Bch 11 k PROPERTY OWNER Company Name: N v)griopi,iv50ju " 5 Name: /v tl 1 6),\ eA.e.),, `��,, t4q,6(..,e \ Name: KeAt co r�, Address: ro yx Q 7 qg Contr Reg No. : xp Date: �vt� xset71M 7,�z /Zofq Address: Po 92886 Phone: ZOS 1 f Sax: ..--- City: ck1ve1a/A a State: Q 4 Zip: qg2-9 06 CONTACT PERSON — person receiving all project communication Company Name: N v)griopi,iv50ju " 5 Name: /v tl 1 6),\ eA.e.),, `��,, t4q,6(..,e \ City: Fti ,+State::Zip: clew Address: ro yx Q 7 qg Contr Reg No. : xp Date: �vt� xset71M 7,�z /Zofq City: (/e.eJid State:014 Zip: Itti / y Phone: ZOS 1 f Sax: ..--- Address: Email: _ __— Address: GENERAL CONTRACTOR INFORMATION Company Name: N v)griopi,iv50ju " 5 Address: o /31)0 214 -ye City: Fti ,+State::Zip: clew Phone: L 2.G /(p�j 63 �/ Fax: r_ e t ` Contr Reg No. : xp Date: �vt� xset71M 7,�z /Zofq Tukwila Business License No.: / 1 0,1 755 HAApplications On Line\2012 Applications\Permit Application Revised - 2-7-12 docx Revised: February 2012 bit ARCHITECT OF RECO Name: (6t.v6.1 e4 S 620-Lcx4 1,17 Address:� 15o I t " Ave 5,„,1d- 10060 Company Name: V �I / A ✓ Architect Name: Engineer Name: Address: Address: City: State: Zip: Phone: Fax: State: Email: Phone: ENGINEER OF RECORD Name: (6t.v6.1 e4 S 620-Lcx4 1,17 Address:� 15o I t " Ave 5,„,1d- 10060 Company Name: V �I / A ✓ Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: (6t.v6.1 e4 S 620-Lcx4 1,17 Address:� 15o I t " Ave 5,„,1d- 10060 City: 5 eatle, State: 1/0 1 a Zip:C 1d Page 1 of 4 BUILDING PERMIT INFORMATI Valuation of Project (contractor's bid price): $ /O3, 501/, fg Existing Building Valuation: $ Describe the scope of work (please rovide detailed information): , MIO &X/.5/» 72®P ..--74,54-all pew ) ' �y pSt t m boa fa, 410r) r r ck.e1-s PAA Zapc membrane and ii rye mItit1, Will there be new rack storage? ❑ .... Yes ® ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: A/ Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ® No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: O Sprinklers ❑ Automatic Fire Alarm ❑ None • Other (specify) M 666 S Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC st oor n d a 53 / 6 a 2nd Floor — 3rd Floor Floors thru Basement Accessory Structure* Attached Garage , Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: A/ Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ® No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: O Sprinklers ❑ Automatic Fire Alarm ❑ None • Other (specify) M 666 S Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INICtMATION — 206-433-0179 Scope of Work (please provide detailed information): PRA9/% hIg ►l r 4n d re P . N. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ...Valley View ❑...Renton ❑ ...Sewer Availability Provided 0... Renton ❑... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑! .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ... Geotechnical Report ❑... Maintenance Agreement(s) . ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑ ... Right-of-way Use - Profit for less than 72 hours O ...Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑ ... Storm Drainage ❑... Abandon Septic Tank ❑... Curb Cut ❑... Pavement Cut ❑... Looped Fire Line ❑ Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public ❑ 91 WO # (2) WO # (2) WO # Private El Private ❑ ❑ ... Grease Interceptor ❑... Channelization ❑ ... Trench Excavation ❑... Utility Undergrounding " WO # (3) " WO # (3) ❑ .. Deduct Water Meter Size " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\F'orms-Applications On Line\20t2 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES —0 0 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER -OR AUTHORI D AGENT: 1• - Signature: Signature: Print Name: ya>n � Mailing Address: PO FO l4 78 j �� 1/(% V2.13 Date: ie 5- 17 Day Telephone: 617 03 7C H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh City State Zip Page 4 of 4 DESCRIPTIONS PermtTRAK . ACCOUNT QUANTITY : .. PAID $1,709:64 D17-0272 Address: 275 ANDOVER PARK W Apn: 9202470010: $1,709.64 Credit Card Fee $49.80 Credit Card Fee R000.369.908.00.00 0.00 $49.80 DEVELOPMENT $1,581.01 PERMIT FEE R000.322.100.00.00 0.00 $1,576.51 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $78.83 TECHNOLOGY FEE R000.322.900.04.00 0.00 $78.83 TOTAL FEES PAID BY RECEIPT: R12634 $1,709.64 Date Paid: Tuesday, October 24, 2017 Paid By: RYAN RILEY Pay Method: CREDIT CARD 02418J Printed: Tuesday, October 24, 2017 11:58 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila Receipt Number R12500 DESCRIPTIONS ACCOUNT 1 QUANTITY PAID $1,055.47 PermitTRAK• D17-0272 Address: 275 ANDOVER PARK W Apn: 9202470010. $1,055.47 Credit Card Fee $30.74 Credit Card Fee R000.369.908.00.00 0.00 $30.74 DEVELOPMENT $1,024.73 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12500 R000.345.830.00.00 0.00 $1,024.73 $1,055.47 Date Paid: Friday, October 06, 2017 Paid By: RYAN RILEY Pay Method: CREDIT CARD 006011 Printed: Friday, October 06, 2017 10:07 AM 1 of 1 SYSTEMS REVISIONS No changes shall by made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittai and may include additional plan review fees. FILE COPY Permit No. t 1 ` 0 �-7 Z - Plan review approval is subject to etoors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and is adotowledged By: Date: /'2 - 2, L(- 2_011 City of Tukwila BUILDING DIVISION o z SEPARATE PERMIT REQUIRED FOR: 0/Mechanical Q'Eriectrical G Plumb ng U as Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 13 2011 LR City of Tukwila BUILDING DIVISION . '� s .,:'.. 1; P -s tar •'f Al w-., • • • .. rw►..fi� �1rt • N! . .'. i ..: .- f�4! '' 4: a 4 AM1 .A..A5 '4'� - !!4 I ^• ,it L�'�'fd�t ..1. ...r..,* t' :op 4, F «, n.• 4 uYC r`r • 40 ii y M :oCT _ -1. � _�PENAIT, �f17 ( r: �r�, f 1 c c RECEIVED CITY OF TUKWILA OCT 062017.: PERMIT CENTER REVIEWED, FOR CODE COMPLIANCE APPROVED OCT 132011 1%1-0311- .4 NifflioningSoluilollille Phone 425 218 2815 Fax 425 252 7855 e-mail: nwroofingsolutions@yahoo.com September 21, 2017 SUBMITTED TO: Key Bank Attn: Michael Hackel JOB LOCATION: Key Bank 275 Andover Park W Seattle, WA 98188 PO Box 2478 Everett, WA 98213 PROPOSAL RE: Key Bank Tukwila (Andover) — Roof Proposal We proposeto do the following work: - 1. Demolish existing BUR roofmg system, including base, lead, and sheet metal flashings a. Legally dispose of debris. 2. Prepare existing substrate to provide a continuous, smooth, dry and clean substrate. 3. Provide and install new mechanically fastened 14" Dens Deck and Rigid insulation crickets. 4 Provide and install a new mechanically fastened, EPDM single -ply membrane. a. Carlisle EPDM 5. Provide and install new EPDM single -ply baseflashings at walls, mechanical curbs and roof penetrations. a. Carlisle EPDM. b. Provide and install new sheet metal coping cap and roof related flashings. 6. Leave site clean and free of debris. 7. Provide owner with manufacturers 20 -year total system warranty, and contractors 2 -.year workmanship warranty Exclusions: Electrical, plumbing, drains and drain parts, ductwork, mechanical, rotting wood replacement, carpentry, interior protection,. interior finish, permits, skylight seals, seismic, masonry and any work not specifically detailed above. COST: RECEIVED CITY OF TUKWILA OCT 062017 PERMIT CENTER Estimate By: Accepted by: REVIEWED FOR CODE COMPLIANCE APPROVED OCT 132017 City of Tukwila BUILDING DIVISION ofing Solutions, LLC. Date: $1193,504.00 + tax Thank you for your interest in our services. If you have any questions, please call. This quote is good for 30 days. Di1-02011-• 5c4.nic —2-15 An8over Afic » WA Neu) roo P A .55e1Obly) M— 5 /7 ftZl-e,7 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 1 3 2011 City of Tukwila BUILDING DIVISION /1/1,tbrekre ER pm covePrd`,,4' 5Peek Pc ly \KooP Ve-c-k:, Plywood RECEIVED CITY OF TUKWILA OCT 0 6 2017 ,IERMIT CENTER 411, Georgia-Pacific DensDeck® Prime Roof Board Technical Service Hotline 1.800.225.6119 or www.densdeck.com Manufacturer Georgia-Pacific Gypsum Georgia-Pacific Canada 133 Peachtree Street 2180 Meadowvale Boulevard, Suite 200 Atlanta, GA 30303 Mississauga, ON L5N 5S3 Technical Service Hotline: 1-800-225-6119 Description DensDeck® Prime Roof Board has been enhanced to provide a broader compatibili and higher performance with roofing adhesives. Face mat enhancements allow adhesives to be applied more uniformly and consistently. In adhered, single ply membrane testing, enhanced DensDeck Prime demonstrated an average of 24% better bond than the original products, when using solvent based adhesives. (Average based on 60 sq.ft./gal coverage rates.)* Choose DensDeck Prime Roof Boards for adhered and self -adhered "peel & stick" roofing systems, as well as hot mopped, cold mastic and torch -applied modified bitumen roofs. Enhanced DensDec Prime Roof Boards create a stronger and more economical installation by reducing. the amounts of mastic or adhesive used and potentially eliminates the field primer. Consult with membrane manufacturer for actual priming requirements. ty k DensDeck Prime Roof Boards are the first and only fiberglass mat gypsum roof boards with a 90 -day weather exposure limited warranty when applied vertically on a parapet wall.** (Limited to 1/2" and 5/8" products only.) Primary Uses Roof system manufacturers and designers have found DensDeck Prime Roof Board to be compatible with many types of roofing systems, including: modified asphalt, single -ply, metal systems, recover board, as well as an overlayment for polyisocyan urate and polystyrene insulation. DensDeck Prime Roof Board can also be used as a form board for poured gypsum concrete deck in roof applications as well as a substrate for spray foam roofing systems. 1/2" (12.7 mm( and 5/8" (15.9 mm) DensDeck Prime Roof Board may also be used in vertical applications as a backer board or liner for the roof side of parapet walls. DensDeck Prime Roof Board may allow the bonding of cold mastic modified bitumen and torching directly to the surface. Consult with the system manufacturer for recommendations on this application. DensDeck Prime Roof Board is the preferred substrate for vapor retarders. Standards and Code Approvals DensDeck Prime Roof Boards are manufactured to meet ASTM C1177 and have the following approvals: • Florida Product Approved • Miami -Dade County Product Control Approved Recommendations and Limitations DensDeck Prime Roof Boards are manufactured to act with a properly designed roof system following good roofing practices. The actual use of DensDeck Prime Roof Board as a roofing component in any system or assembly is the responsibility of the roofing system's design authority. Consult with the appropriate system manufacturer and/or design authority for system and assembly specifications and instructions on applying other products to DensDeck Prime Roof Board. Georgia-Pacific does not warrant and is not responsible for any systems or assemblies utilizing DensDeck Prime Roof Board or any component in such systems or assemblies other than DensDeck Prime Roof Board. The need for a separator sheet between the DensDeck Prime Roof Board and the roofing membrane must be determined by the roof membrane manufacturer or roofing system designer. * Testing was done in accordance with FM approvals 4470, Appendix C: Small Scale Tests, Membrane Delamination Tests for Roofing Membranes and Substrates Using Tensile Loading. ** For complete warranty details, visit ww.DensDeck.com. (Limited to 1/2" and 5/8" products only) NED FOR CODE COMPLIAKEt APPROVED OCT 13 2011 ame Confirm any priming requirements with the membrane manufacturer. When applying solvent -based adhesives or primers, allow sufficient time for the solvent to flash off to avoid damage to roofing components. DensDeck Prime Roof Boards should not be subjected to abnormal or excessive loads or foot traffic, such as, but not limited to,.use on plaza decks or under steel -wheeled equipment that may fracture or damage the panels. Provide suitable roofing system protection when required. When using DensDeck Prime Roof Boards for hot -mopped applications, Georgia-Pacific recommends maximum asphalt application temperatures of 425°F (218°C) to 450°F (232°C). Application temperatures above these recommended temperatures may adversely affect roof system performance. Consult and follow the roofing system manufacturer's specifications for full mopping applications and temperature requirements. When using DensDeck Prime Roof Board as a substrate for torch applications, ensure that the product is dry and that the proper torching technique is used. Limit the heat to the DensDeck Prime Roof Board. Maintain a majority of the torch flame directly on the roll. Conditions beyond the control of Georgia-Pacific, such as weather conditions, dew, leaks, application temperatures and techniques may cause adverse effects with roofing systems. Handling and Use—CAUTION This product contains fiberglass facings which may cause skin irritation. Dust and fibers produced during the handling and installation of the product may cause skin, eye and respiratory tract irritation. Avoid breathing dust and mini- mize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use a dust mask or NIOSH/ MSHA approved respirator as appropriate in dusty or poorly ventilated areas. Moisture Management DensDeck Prime Roof Boards, like otlber components used in roofing systems, must be protected from exposure to moisture before, during and after installation. Remove the plastic packaging from all DensDeck Prime Roof Board immediately upon receipt of delivery. Failure to remove the plastic packaging may result in entrapment of condensation or moisture. DensDeck Prime Roof Board stored outside must be stored level and off the ground and protected by a breathable waterproof covering. Provide means for air circulation around and under stored bundles of DensDeck Prime Roof Board. DensDeck Prime Roof Board must be covered the same day as installed. Avoid application of DensDeck Prime Roof Boards during rain, heavy fog and any other conditions that may deposit moisture on the surface, and avoid the overuse of non -vented, direct -fired heaters during winter months. When roofing systems are installed on new poured concrete or light weight concrete decks or when re -roofing over an existing concrete deck, a vapor barrier should be installed above the concrete to retard the migration of water from the concrete into the roof assembly. Always consult the roofing system manufacturer or design authority for specific instructions for applying other products to DensDeck Prime Roof Boards. Moisture vapor movement by convection must be eliminated, and the flow of water by gravity through imperfections in the roof system must be controlled. After a leak has occurred, no condensation on the upper surface of the system should be tolerated, and the water introduced by the leak must be dissipated to the building interior in a minimum amount of time. Although DensDeck Prime Roof Boards are engineered with fiberglass facings and high density gypsum cores, the presence of free moisture can have a detrimental effect on the performance of the product and the installation of roofing membranes. For example, hot asphalt applications can blister; torched modified bitumen may not properly bond; and adhesives for sing) . ly meruhra e,&u vjioLdyy properly. eAl 1361 jukkA 1 I a /fl(tpTY OF TUKWV.ILA can6nued-► tor /L4f3' tin h IN: OCT 0 6 2017 Date City of Tukwila BUILDING DIVISION %-5 /7 PERMIT CENTER Stamps / Signatures 1,4, Georgia-Pacific DensDeck® Prime Roof Board Technical Service Hotline 1.800.225.6119 or www.densdeck.com Moisture accumulation may also significantly decrease wind uplift and vertical pull resistance in the system or assembly. DensDeck® Prime Roof Boards containing excessive free moisture content may need to be evaluated for structural stability to assure wind uplift performance. {Fire Resistance Classifications DensDeck Prime Roof Boards are excellent fire barriers over combustible and noncombustible roof decks, including steel decks. UL 790 Classification. jDensDeck Prime Roof Boards'have been classified by (Underwriterslabdratories LLC (UL)'for use as a fire barrier over combustible and • noncombustible decks in accordance with the ANSI/UL 790 test standard. The- UL heJUL classification includes a comprehensive Class A, B or C rating. For additional information concerning the UL 790 classification, consult the UL Certification Directory. UL 1256 Classification. DensDeck Prime Roof Boards have also been classified by UL in roof deck constructions for internal (under deck) fire exposure in accordance with the ANSI/UL 1256 Steiner Tunnel test. For additional information concerning the UL 1256 classification, consult the UL Certification Directory. FM Class 1 Approvals. DensDeck Prime Roof Boards are included in numerous roofing assemblies with a Factory Mutual (FM) Class 1 fire rating. 1/4" (6.4 mm) DensDeck Prime Roof Boards have passed testing under the FM Calorimeter Standard 4450 Physical Properties and have been approved by FM as such for insulated steel deck roofs when installed according to the conditions identified by FM. For more information concerning FM Approvals and FM Class 1 assemblies with DensDeck Prime Roof Boards, consult FM or RoofNav®. Type X 5/8" (15.9 mm) DensDeck® Prime Fireguard® Roof Boards are manufactured to meet the "Type X" requirements of ASTM C1177 for increased fire resistance beyond regular gypsum board. UL Fire Resistance Ratings. 5/8" (15.9 mm) DensDeck Prime Fireguard Roof Boards are designated as Type DD by UL and included in assembly designs investigated by UL for hourly fire resistance ratings. 5/8" (15.9 mm) DensDeck Prime Fireguard Roof Boards may also replace any unclassified 5/8" (15.9 mm) gypsum board in an assembly in the UL Fire Resistance Directory under the prefix "P". Flame Spread and Smoke Developed. When tested in accordance with ASTM E84, DensDeck Prime Roof Boards had Flame Spread 0, Smoke Developed 0. Wind Uplift DensDeck Prime Roof Boards are included in numerous assemblies evaluated by FM or other independent laboratories for wind uplift performance. For information concerning such assemblies, please visit wwwroofnay.com. Properties Thickness, nominal 1/4" (6.4 mm) 1/4" (6.4 mm) ± 1/16" (1.6 mm) 1/2" (12.7mm) 1/2" (12.7 mm) ± 1/32" (.8 mm) 5/8" (15.9 mm) 5/8" (15.9 mm) ± 1/32" (.8 mm) Width, standard 4' (1219 mm) ± 1/8" (3 mm) 4' (1219 mm) ± 1/8" (3 mm) 4' (1219 mm) ± 1/8" (3 mm) Length, standard 4' (1219 mm) and 8' (2438 mm) ± 1/4" (6.4 rem) 4' (1219 mm) and 8' (2438 rem) ± 1/4" (6.4 mm) 4' (1219 mm) and 8' (2438 mm)± 1/4" (6.4 mm) Weight, nominal, lbs./sq. ft. (Kg/m2) 1.2 (5.9) 2.0 (9.8) 2.5 (12.2) Surfacing' Fiberglass mat with non -asphaltic coating Fiberglass mat with non -asphaltic coating Fiberglass mat with non -asphaltic coating Flexural Strength', parallel, lbf. min. (N) >>_40 (178) x80 (356) >-100 (444) Flute Spanability' 2-5/8" (66.7 mm) 5" (127 mm) .. 8" (203 mm) Permeance', Perms (ng/Pa•S•m2) >30 (>1710) >23 (>1300) >17 (>970) II Value°, ft2•°F•hr/BTU (m2•K/W) .28 .56 .67 Linear Variation with Change in Temp., in/in °F (mm/mm/C°) 8.5010.6(15.3x10.6) 8.5x10 -6(15.3x10-') 8.5x10.6(15.3x104) Linear Variation with Change in Moisture 6.25 x 10-6 6.25 x 10.6 6.25 x 106 Water Absorption', % max <10 <10 <10 Compressive Strength', psi nominal 900 900 900 Surface Water Absorption, grams, nominal <2.0 <2.0 <2.0 Flame Spread, Smoke Developed (ASTM E84) 0/0 0/0 0/0 Bending Radius 4' (1219 mm) 6' (1829 mm) 8' (2438 mm) 1. Tested in accordance with ASTM C473 method B. 2. Tested in accordance with ASTM E661. 3. Tested in accordance with ASTM E96 (dry cup method). U.S.A. Georgia-Pacific Gypsum Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum II LLC Canada Georgia-Pacific Canada LP SALES INFORMATION AND ORDER PLACEMENT U.S.A. West: 1-800-824-7503 Midwest: 1-800-876-4746 South Central: 1-800-231-6060 Southeast: 1-800-327-2344 Northeast: 1-800-947-4497 CANADA Canada Toll Free:1-800-387-6823 Quebec TollFree:1-800-361-0486 TECHNICAL INFORMATION U.S.A. and Canada:.1-800-225-6119, www.gpgypsum.com ©2015 Georgia-Pacific Gypsum U.C. All rights reserved. 5/15. GP -TM Lit. Item #102169. 4. Tested in accordance with ASTM C518 (heat flow meter). 5. Specified values per ASTM C1177. 6. Tested in accordance with ASTM C473. TRADEMARKS DENSDECK, FIREGUARD and the GEORGIA -PACIFIC logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. ROOFNAV is a registered mark of FM Global. WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty information for this product, please go to www.gpgypsum.com and select the product for warranty information. All sales of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com. UPDATES AND CURRENT INFORMATION The information in this document may change without notice. Visit our website at www.gpgypsum.com for updates and current information. CAUTION For product fire, safety and use information, go to www.buildgp.com/safetyinfo or call 1-800-225-6119. FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other • specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system. 3/1/2018 City of Tukwila Department of Community Development MICHAEL HACKEL PO BOX 92986 CLEVELAND, OH 44194 RE: Permit No. D17-0272 KEY BANK 275 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/22/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/22/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0272 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0272 DATE: 10/09/17 PROJECT NAME: KEY BANK SITE ADDRESS: 275 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 4wc, Building Division 411 Public Works ❑ AA AA to -17 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/10/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 11/07/17 ❑ Approved with Conditions ri Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 NW ROOFING SOLUTIONS LLC0 Home. Espanol Contact Safety & Health Claims & Insurance 11111) Washington State Department of Labor & Industries Search L&I Page 1 of 2 r1-7, Index Help My L&I Workplace Rights Trades & Licensing NW ROOFING SOLUTIONS LLC Owner or tradesperson Principals MADSEN, GEORGE, PARTNER/MEMBER (End: 07/13/2017) Doing business as NW ROOFING SOLUTIONS LLC WA UBI No. 602 290 276 PO BOX 2478 EVERETT, WA 98213 425-231-8273 SNOHOMISH County Business type Limited Liability Company Governing persons GEORGE MADSEN GEORGE KRAAGE MADSEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties ROOFING License no. NWROORS971 M4 Effective — expiration 07/24/2003— 07/24/2019 Bond TRAVELERS INDEMNITY CO OF AME Bond account no. 104098019 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 07/24/2003 07/23/2003 Expiration date Until Canceled Insurance Kinsale Insurance Company $1,000,000.00 Policy no. 01000000119-5 Received by L&I Effective date 04/26/2017 12/10/2015 Expiration date 05/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings, No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602290276&LIC=NWROORS971M4&SAW= 10/17/2017