HomeMy WebLinkAboutPermit D17-0274 - WESTFIELD SOUTHCENTER MALL - LED LIGHTING AND WOOD SLAT CEILINGWESTFIELD 2800 SOUTHCENTER MALL D17-0274 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 3597000150 Permit Number: 017-0274 2800 SOUTHCENTER MALL Project Name: WESTFIELD Issue Date: 11/17/2017 Permit Expires On: 5/16/2018 Owner: Name: Address: Contact Person: Name: Address: „ WA, PAUL ENGERT 26990 SE 22ND WAY , SAMMAMISH, WA, 98075 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA, 98580 License No: JEMCOI*033DD Lender: Name: WESTFIELD Address: Phone: (206) 225-1443 Phone: (253) 843-2765 Expiration Date: 5/15/2019 DESCRIPTION OF WORK: REMOVE EXISTING SOFFIT LIGHTING AND INSTALL NEW LED LIGHT AND WOOD SLAT CEILING AT WEST MALL ENTRY - BETWEEN NORDSTROM AND SEARS Project Valuation: $110,000.00 Type of Fire Protection: Type of Construction: IIB Electrical Service Provided by: Sprinklers: NO Fire Alarm: NO Fees Collected: $2,804.76 Occupancy per IBC: Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature:. Date: L H (7„ E 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: clzi Print Name141,,, Date: (077% This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4)(EXTEND SPRINKLER PROTECTION TO COMBUSTIBLE EAVES.) 2: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 3: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 7: ***BUILDING PERMIT CONDITIONS*** 8: Work shall be installed in accordance with the approved construction documents, and any changes made . during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 0 0 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ***BUILDING PERMIT CONDITIONS*** 16: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 17: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 18: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 19: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 20: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 21: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 22: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: tO n Date Application Expires: 0 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 2800 SouthcenterA�7°�Mall !- Vp' Tenant Name: VVi Wet et %1\ PROPERTY OWNER Name: Paul Engert Name: Westfield Address: 26990 SE 22nd Way Address: 2800 Southcenter Mall City: Sammamish State: WA City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Paul Engert Company Name: Engert Architecture LLC Address: 26990 SE 22nd Way Architect Name: Paul Engert City: Sammamish State: WA Zip: 98075 Phone: (206) 225-1443 Fax: City: Sammamish State: WA Email: paul@engertarchitecture.com State: GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: Engert Architecture LLC Company Name: N/A Architect Name: Paul Engert Address: Address: 26990 SE 22nd Way City: City: Sammamish State: WA City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 13-9-1 l.docx Revised: August 2011 bh King Co Assessor's Tax No.: 920247-0010 Suite Number: None Floor: 1st New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Name: None w1T, Company Name: Engert Architecture LLC Company Name: N/A Architect Name: Paul Engert Address: 26990 SE 22nd Way City: City: Sammamish State: WA Zip: 98075 Phone: (206) 225-1443 Fax: Email: paul@engertarchitecture,com State: ENGINEER OF RECORD Name: None w1T, ap Company Name: N/A Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: None w1T, ap Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 110,000 Existing Building Valuation: $ 26,000,000 Describe the scope of work (please provide detailed information): Remove existing soffit lighting and install new LED lights and wood slat ceiling and west mall entry. \AI bbiANtal Nord Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes VI No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 11 Floor 1,572 0 0 II -B None 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes VI No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate O .. Highline ❑ ... Valley View 0 .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ... Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor 0 ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line 0 .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private 0 ❑ ...Water Main Extension Public 0 Private ❑ 35 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ( O�RIZED AGENT: Signature: Date: 10/06/2017 Print Name: Paul Engert Day Telephone: (206) 225-1443 Mailing Address: 26990 SE 22nd Way Sammamish WA 98075 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 (.does Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY'`' PAID PermitTRAK $1,714.46 D17-0274 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $1,714.46 DEVELOPMENT $1,633.03 PERMIT FEE R000.322.100.00.00 0.00 $1,628.53 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $81.43 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12819 R000.322.900.04.00 0.00 .. $81.43 $1,714.46 Date Paid: Friday, November 17, 2017 Paid By: J E M CONSTRUCTION INC Pay Method: CHECK 15397 Printed: Friday, November 17, 2017 8:37 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila Receipt; Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY f Y: PAID $1,090.30 D17-0274 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $1,090.30 Credit Card Fee $31.76 Credit Card Fee R000.369.908.00.00 0.00 $31.76 DEVELOPMENT $1,058.54 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12513 R000.345.830.00.00 0.00 $1,058.54 G $1,090.30 Date Paid: Friday, October 06, 2017 Paid By: PAUL ENGERT Pay Method: CREDIT CARD 006678 Printed: Friday, October 06, 2017 3:12 PM 1 of 1 ? SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit D;7-627 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: }UltkQ/',l- Al Wim '/,ef'LD it4/ LL Address: 2 cl'r lit. Date Called: --- Special Instructions: moi/GpP' i O frgii'6 `Nc 1/3 a 5'f pc 5eveici T Av 'fnr PO 77& r Date Wanted: p t /2-`%ir+ a.rri p.m. Requester: / Phone No: 253— 6aD(e_5 2:3 P2 Approved per applicable codes. E] Corrections required prior to approval. COMMENTS: OK- 13U)Lp/N6- /411 -- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Exterior Lighting LTG -EXT 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 10/6/2017 Exterior Lighting Zone Table C405.5.2(1) Specified by jurisdiction. Q zone 1 Q zone 2 Q zone 3 Q zone 4 Zone selection required to enable LTG -EXT form For Buildir{13rte CITY OF TUKWILq OCT 0 6 2017 PERMIT CENTER Calculation Area Q Q Addition - Q Addition stand alone + existing Alteration with < 50% Q Alteration with =' 50% ext. O ext. wattage replaced wattage replaced BuildingGrounds Applies to luminaires > 100 Watts Efficacy > 80 lumens/watt Exemption 360 ❑ Controlled by motion sensor Tradable Maximum Allowed Lighting Wattage NOTE 1 Base Site Allowance: 0 Tradable Surfaces Surface Description Area (ft`), perimeter (If) or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) re Enter Tota f Exisa� n- able C ategories (prior to alteration): �� -- Awa AM■ . A \1A/� Enter Total Existing Wattage in Tradable Categories (prior to alteration): Total Allowed Tradable + Site Allowance Watts: 1350 1350 Tradable Proposed Lighting Wattage Tradable Surface Fixture Description NOTE s, 4 Number of Fixtures Watts per Fixture NOTE 5 Watts Proposed Entry Canopies LED Recessed 18• 20 360 j I 1 Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: watts plus the base site allowance. Any base site allowance not needed to make 360 tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage N011 Site Allowance Remaining: 0 Non -Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) j I 1 re Enter Tota f Exisa� n- able C ategories (prior to alteration): �� -- Awa AM■ . A \1A/� Non -Tradable Proposed Lighting Watta Non -Tradable Surface o rnx.+V Fixture Descriptio NOTE 3, 4 11.10, 'f Fixtures Watts Watts per Fixture NOTE 5 Watts Proposed 0 ei I 1 Non -tradable proposed watts may not exceed allowed watts for ny incifari lOT I UVNI bn-Tra able Watts Exceeding LPA: surface unless the total excess watts for all non -tradable surfac slMM DIVISION remaining site allowance. Remaining Site Allowance: 0 0 Exterior Lighting COMPLIES WITH MAX. ALLOWANCE Note 1 - List all unique exterior sufaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop down menu. Note 2 - List all proposed lighting fixtures including existing -to -remain fixtures. Note 3 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable). Note 4 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner as new fixtures. Identify as existing in fixture description. Note 5 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. Dri-0714 oE ENGERT ARCHITECTURE LLC November 5, 2017 Rachelle Ripley Permit Technician City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Re: Project D17-0274 Westfield W. Entry Soffit Upgrades Dear Rachelle, The purpose of this letter is to response to the plan review comments received in your letter dated 10/2/2017. I have followed the format established in your letter with my responses. 1. Provide architectural stamp, signature and date of that signature on each sheet. All documents created by a design professional shall be provide with current stamp and dated signatures. See General note above. Will Comply. 2. The plans appear to indicate removal of existing fixtures to install the new LED lighting. For clarification, indicate if this requires removal of portions of that existing soffit for access to replace lights. In any case specify how the existing soffit enclosure assembly shall be repaired or sealed back to its original condition. Specify existing soffit materials. Existing soffit material is concrete board with textured stucco finish over wood framing members @ 24" o.c. The original lighting housing will be removed, and the new housing installed. I do not know if the opening will need to be enlarged to accommodate the new fixture. If it is required to be made larger, the soffit can be sealed by adding a layer of 5/8" dens -glass gold exterior rated sheathing around the newly install lighting housing. 3. Provide specific details for the installation of the metal furring strips specifying type of furring to include length and type of fasteners. Specify type of soffit framing. %" x 20 ga. metal hat channels will be installed directly to the underside of the concrete board using 2 %" framing screws @ 24" o.c. The screws will fasten to the wood soffit framing members CORRECTION LTR#. N 26990 SE 22"d Way Sammamish, WA 98075 206 225-1443 RECEIVED OF TUKWILA NOV 06 2017 www.engertarchitecture.com PERMIT CENTER Westfield W. Soffit Upgrades Plan Response Letter 4. Provide details for the soffit access panel and specify how it shall be secured or locked. It has been determined that the existing metal soffit access panels will remain. We will provide a removal section of ipe wood slats, approximately a 2' x 2' section. This is the same approach used at the existing ipe wood soffit. 5. I believe the key reference at building section R should be #4. Please clarify. This correction has been made to the new drawing set. 6. For clarification, indicate where the existing access panel is as indicated in General note #2 or is that the same as Key Note #2. I have revised Keynote #2, please see sheet A2.1. 7. Provide manufactures specification for the wood slats for verification that the slats comply with fire resistant type materials for Type II building. The ipe wood slats shall comply with Section 1405.5 Wood Veneers. Wood veneers on exterior walls of buildings of Type I, II, III and IV construction shall be not less than 1 inch (25 mm) nominal thickness, 0.438 -inch (11.1mm) mm) exterior hardboard siding or 0.375 -inch (9.5 mm) exterior -type wood structural panels or particleboard and shall conform to the following: 1. The veneer shall not exceed 40 feet (12 190 mm) in height above grade. Where fire - retardant -treated wood is used, the height shall not exceed 60 feet (18 290 mm) in height above grade. 2. The veneer is attached to or furred from a noncombusti-ble backing that is fire -resistance rated as required by other provisions of this code. 3. Where open or of spaced. wood veneers (without concealed spaces) are used, they shall not project more than 24 inches (610 mm) from the building wall. It is my hope that this letter and plan corrections have addressed your concerns. Please feel free to call or email should you have any additional comments that I might address. Sincerely, 1:3A Paul Engert Architect October 25, 2017 City of Tukwila Department of Community Development PAUL ENGERT 26990 SE 22ND WAY SAMMAMISH, WA 98075 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0274 WESTFIELD - 2800 SOUTHCENTER MALL Dear PAUL ENGERT, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Provide architectural stamp, signature and date of that signature on each sheet. All documents created by a design professional shall be provide with current stamp and dated signatures. See General note above. 2. The plans appear to indicate removal of existing fixtures to install the new LED lighting. For clarification, indicate if this requires removal of portions of that existing soffit for access to replace lights. In any case specify how the existing soffit enclosure assembly shall be repaired or sealed back to its original condition. Specify existing soffit materials. 3. Provide specific details for the installation of the metal furring strips specifying type of furring to include length and type of fasteners. Specify type of soffit framing. 4. Provide details for the soffit access panel and specify how it shall be secured or locked. 5. I believe the key reference at building section R should be #4. Please clarify. 6. For clarification, indicate where the existing access panel is as indicated in General note #2 or is that the same as Key Note #2. 7. Provide manufactures specification for the wood slats for verification that the slats comply with fire resistant type.materials for Type II building. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Note: Contingent on respoyo these corrections, further plan review may r'st for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, elle Riple Permit Technician File No. D17-0274 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 44ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0274 DATE: 11/06/17 PROJECT NAME: WESTFIELD SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: �4e Building ivsion 61'1111 Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/07/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/05/17 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: 'Permit Center Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 CPEflM1T COORS COPY � PLAN REVIEW/ROUTING SLIP 11. PERMIT NUMBER: D17-0274 DATE: 10/09/17 PROJECT NAME: WESTFIELD - WEST SIDE SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-3 Cora, D -t\ -i7 Building Division IF Public Works Wt Fire Prevention Structural El \r1 t_pc 04-17 Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/10/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/07/17 Approved U Approved with Conditions Corrections Required Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 Date: 11/6/2017 0 City of Tukwila 0 REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D17-0274 ❑ Response to Incomplete Letter # a Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Westfield Project Address: 2800 Southcenter Mall Contact Person: Paul Engert Phone Number: 206 225-1443 Summary of Revision: Revisions or responses to 7 items in correction letter. RECEIVED CITY OF TUKWILA NOV Q 6 2017 PERMIT CENTER Sheet Number(s): A1.0 & A2.1 "Cloud" or highlight all areas of revision including & of revisi n C Received at the City of Tukwila Permit Center by: Entered in TRAKiT on i _ ( 7 W:\Permit Center\Templates\Forms\Revision Submittal Formdoc Revised: August 2015 J E M CONSTRUCTION INC Washington State Department of Labor & industries v Home Espanol Contact Search L&I A -Z index Help Safety & Health Claims & Insurance Workplace Rights J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA 98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. JEMCOI*033DD .Effective — expiration 03/04/1997— 05/15/2019 Bond CBIC Bond account no. SA7695 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled Insurance American States Insurance Co $1,000,000.00 Policy no. 01C12205496 Received by L&I Effective date 03/23/2017 04/16/2015 Expiration date 04/16/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 1 of 2 My L&r Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 11/17/2017 A1.0 -(COVER SHEET).dwg 11/04/17 - 1:46pm ABBREVIATIONS ADJ ALT AFF ALUM ANG ANOD AC BLDG BLKG BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FACTORY FINISH OR FINISH FLOOR FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR GRAPHIC LEGEND II_ III III II III—III— • • S1S-888()()l)' r//////�1 EARTH GRAVEUROCK CONCRETE ASPHALT PAVING WOOD FRAMING BLOCKING OR SHIM FINISH WOOD GLASS(ELEVATION) GLASS(SECTION) GYPSUM WALL BOARD CAULKING/SEALANT PLYWOOD BRICK ACOUSTIC TILE RIGID INSULATION BATT INSULATION METAL FTIC FT FURN GA GALV GL GW OR GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FURNISHED BY TENANT INSTALLED BY CONTRACTOR FOOT/FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE SYMBOLS LEGEND VCT FINISH SYMBOL INTERIOR ELEVATION REFERENCE ELEVATION / SECTION REFERENCE EGRESS TRAVEL DIRECTION EGRESS PATH EGRESS START POINT OFC (1024) V 9'-0" GW O DETAIL REFERENCE DETAIL SECTION / PLAN CUT ENLARGED PLAN REFERENCE GRID LINES ROOM NAME ROOM NUMBER DOOR NUMBER WINDOW NUMBER CEILING HEIGHT CEILING TYPE GW = GYPSUM WALLBOARD AC = ACOUSTICAL CEILING WD = WOOD CEILING KEYNOTE WALL TYPE DATUM OR PROPERTY CORNER OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERST TYP ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL UNO UNLESS NOTED OTHERWISE VAR VCT VERT VWC W/ W/0 WC WD VARIES VINYL COMPOSITION TILE VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD ELECTRICAL SYMBOLS () DUPLEX OUTLET ] DEDICATED DUPLEX OUTLET 3* FOURPLEX OUTLET DEDICATED FOURPLEX OUTLET VOICE / DATA OUTLET RECESSED FLOOR VOICE / DATA BOX 208V OUTLET 220V OUTLET OVERHEAD FEED FURNITURE POWER / DATA POLE OVERHEAD ELECTRICAL DROP CORD SPECIAL OUTLET (SEE KEYNOTES) CARD READER OUTLET ELECTRICAL JUNCTION BOX SECURITY SYSTEM ACCESS PANEL LIGHTING SWITCH THREE-WAY LIGHT SWITCH LIGHTING OCCUPANCY SENSOR HVAC THERMOSTAT CEILING SYMBOLS 0 -o- FO 9=0" ACS 2X4 RECESSED LED LIGHT FIXTURE 2X4 RECESSED NIGHT LIGHT FIXTURE 2X2 RECESSED LED LIGHT FIXTURE 2X2 RECESSED NIGHT LIGHT FIXTURE 4" RECESSED LINEAR FIXTURE 1X4 SURFACE MOUNTED LIGHT FIXTURE 1X4 SURFACE MOUNTED LIGHT FIXTURE LIGHTED EXIT SIGN WITH OR WITHOUT DIRECTIONAL ARROW (AS INDICATED) 4" RECESSED LED LIGHT FIXTURE 6" RECESSED LED LIGHT FIXTURE PENDANT LED LIGHT FIXTURE WALL MOUNTED SCONCE LIGHT FIXTURE 24" WALL MOUNTED VALANCE LIGHT FIXTURE GENERAL NOTES 1. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS INCLUDING LOCAL JURISDICTIONAL AND OWNER REQUIREMENTS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK THAT COULD BE EFFECTED BY THE DISCREPANCY SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 4. SEPARATE PERMITS, WHEN REQUIRED AND/OR ARE DESIGN/BUILD , SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND SUPPLEMENTAL DOCUMENTS SHALL BE PROVIDED FOR REVIEW BY THE AUTHORITY HAVING JURISDICTION AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. 5. THE INSTALLATION OF AUTOMATIC FIRE SPRINKLER AND ALARM SYSTEMS SYSTEMS SHALL COMPLY WITH THE INTERNATIONAL BUILDING AND FIRE CODES. 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE SCOPE OF WORK SHALL BE PERFORMED BY A APPROVED INSPECTION SERVICE APPROVED BY THE AUTHORITY HAVING JURISDICTION OR BUILDING OFFICIAL. 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. 8. DIMENSIONS ARE TO LEASE LINES UNLESS NOTED OTHERWISE. 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER. 12. ALL WORK AND MATERIALS SHALL BE PLACED / INSTALLED IN FULL ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE IN AFFECT WITHIN THE JURISDICTION WORK IN PERFORMED AND ALL OTHER APPLICABLE STATE OR LOCAL LAWS AND REGULATIONS AS ARE APPLICABLE. NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO PERMIT WORK WHICH IS NOT IN CONFORMANCE WITH ANY CODE OR REGULATION IN AFFECT. 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICES. 15. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED AT LOCATION PER IBC SEC. 718 . 16. WHEN CHANGES TO THE MECHANICAL SYSTEM REQUIRE A MECHANICAL PERMIT THEY SHALL COMPLY WITH THE CURRENT MECHANICAL CODE, WASHINGTON STATE ENERGY CODE AND ANY LOCAL JURISDICTION REQUIREMENTS. 17. PROVIDE ILLUMINATED EXIT SIGNAGE WITH MIN. 45 MINUTES BACKUP POWER AT ALL REQUIRED EXITS. 18. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND ALTERED BY NEW CONSTRUCTION. 19. CONTRACTOR IS TO COMPLY WITH CHAPTER 33 OF THE INTERNATIONAL BUILDING CODE CONCERNING PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. 20. ASBESTOS AND HAZARDOUS WASTE : THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. 6" INSTALLED CEILING HEIGHT CEILING TYPE: AC = SUSPENDED ACOUSTICAL TILE GB = GYPSUM WALLBOARD PLANNING APPROVED No changes can be made. to these plans without approval from the Planning Division of DCD Approved By: L %-r-0 t on Date: AREA OF WORK CODE INFORMATION 2015 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS ICC/ANSI A117.1-09, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 2015 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLER SYSTEM: FIRE SEPARATION REQUIREMENTS: M (MERCANTILE - COVERED MALL) II -N FULLY SPRINKLERED IBC SECTION 1024.5 OPENINGS - DOORS TO EXIT PASSAGEWAYS SHALL BE PROTECTED BE 60 MINUTE RATED DOOR AND FRAME ASSEMBLY THAT IS SELF CLOSING. EACH TENANT SPACE SHALL BE SEPARATED BY A FIRE PARTITION (60 MINUTES RATED) IN ACCORDANCE TO IBC SECTION 708. AREA OF WORK: 1,572 SQ. FT. LIGHTING REQUIREMENTS EXISTING EXTERIOR LIGHT FIXTURES ARE BEING REPLACED WITH NEW LED FIXTURES. ENERGY REQUIREMENTS NO BUILDING ENVELOPE MODIFICATIONS ARE PROPOSED. PLUMBING FIXTURE REQUIREMENTS NO PLUMBING WORK PROPOSED IN SCOPE OF WORK. DEFERRED SUBMITTALS - DESIGN BUILD ALL DEFERRED SUBMITTALS - DESIGN BUILD ITEMS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR HIS SUBCONTRACTORS AND SHALL BE SUBMITTED TO WESTFIELD PROJECT MANAGER BY GENERAL CONTRACTOR. HE / THEY ARE RESPONSIBLE FOR ALL PERMIT COSTS AND PERMITTING OF SAME. • ELECTRICAL SYSTEMS - DESIGN / BUILD PROJECT DIRECTORY ARCHITECT / CONTACT: ENGERT ARCHITECTURE LLC 26690 SE 22nd WAY SAMMAMISH, WASHINGTON 98075 OWNER: GENERAL CONTRACTOR: TAX PARCEL # 920247-0010 CONTACT: PHONE: EMAIL: PAUL ENGERT (206) 225-1443 paul@engertarchitecture.com WESTFIELD SOUTHCENTER 2800 WESTFIELD MALL TUKWILA, WASHINGTON 98188 CONTACT: PHONE: EMAIL: TBD LEGAL DESCRIPTION WAYNE JOHNSON 206-714-3485 wjohnson@us.westfield.com SEPARATE PERMIT REQUIRED�'FOR: t Mechanic> tier tlectrlcal grflumbinp was Pipir City of Tukwila EIUIL.DING DIVISION WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) ADDRESS 2800 SOUTHCENTER TUKWILA, WA 98188 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE. Revisions will require a new plan submittal and may include additional plan review fees. PROJECT DESCRIPTION REMOVE AND REPLACE EXISTING ROUND DOWNLIGHTS WITH NEW SQUARE LED FIXTURES. FURNISH AND INSTALL NEW IPE WOOD SLAT SOFFIT ON FURRING STRIPS TO MATCH SOFFIT IN FRONT OF LULULEMON. INDEX OF DRAWINGS A1.0 COVER SHEET A2.1 SOFFIT PLAN / SECTION / DETAILS FILE COPY Permit No. h 0;.7 Li Plan view approval is s9 an tPe violation of any adopted of approved Field Copy and Date: 'NI I —I / / City of Tukwila BUILDING DIVISION ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com REVIEWED FOR CODE COMPLIANCE t APPROVED NOV 07 2017 r • 4ty of Tu k riga BUILDING and omissions. not authorize R ipt 1a .� wedged: CORRECTION LTR# 1.-- EXTERIOR SOFFIT CITY OF TUKWI LA NOV 0 6 2017 PERMIT CENTER OVERALL MALL PLAN irk Westfield Southcenter CD Co 0 CO 1 Co C3) cts U Mffic c I— W v' Cl) CONSULTANT STAMP REGISTERED AR HITECT STATE OF WASH''GTON REVISIONS: A PLAN REVIEW COMMENTS 11/6/2107 PHASE / DELIVERABLE PERMIT SET DATE: DRAWN: PROJECT NO: 10/2/2017 PE 17-026 APPROVED: PE .) q SHEET TITLE: COVER SHEET SHEET NO: A1 .0 A21. -(SOFFIT PLAN).dwg ENLARGED - SOFFIT PLAN 1/2" =1'-0" GENERAL NOTES 1. CONTRACTOR SHALL FURNISH AND INSTALL NEW LED LIGHT FIXTURES WITHIN SAME LOCATION OF EXISTING DOWN LIGHTS. CONTRACTOR SHALL CUT, PATCH AND REPAIR SOFFIT TO ACCOMMODATE NEW LIGHT FIXTURES. 2. CONTRACTOR SHALL ALLOW FOR EXISTING ACCESS PANELS TO REMAIN OPERATIONAL AFTER INSTALLATION OF WOOD SLATS. WOOD SLATS SHALL COVER ACCESS PANELS SIMILAR TO EXISTING IPE ACCESS PANELS TYPICAL. 3. CONTRACTOR SHALL PROTECT BASE BUILDING STRUCTURE INCLUDING SIDEWALK AND DRIVE. 4. SIDEWALK SHALL REMAIN OPEN DURING BUSINESS HOURS. ALL EXISTS SHALL REMAIN OPEN AND EGRESS PATHS MAINTAINED AT ALL TIMES. 0 0 0 KEYNOTES OREMOVE EXISTING SOFFIT LIGHT FIXTURES AND INSTALL NEW LED FIXTURES AS INDICATED. USE EXIST. BRANCH ELECTRICAL CIRCUIT, FIELD VERIFY. SEE DETAIL 5 THIS SHEET FOR LIGHT FIXTURE O2' X 2' REMOVABLE WOOD SLAT SECTION TO ALLOW ACCESS TO EXISTING SOFFIT ACCESS PANEL. SECURE WOOD SLATS TO FURRING STRIPS WITH (4) 2%" FRAMING SCREWS ® 1 y - /Y0•o • elf ,L I-- .I.S • . STRUCTURE. OEXIST. BUILDING COLUMN 0 EXIST. IPE SOFFIT AND LIGHTING 0 0 0 NEW IPE WOOD SLAT SOFFIT OVER METAL FURRING. MATCH EXISTING EXPOSURE AT EDGES SECTION '1/4" =1'-0" MATCH EXIST. WOOD SLAT DETAIL 3" =1'-0" 0 p4,440vv-01-5'0, MP* lehlerldp4tTT. .j%, 011 At Ark Kytk IjtIt; ‘0171! Ar.ArkItMIM irt" N alf nylon mi II r �'11.11110 1 11 ■ 1 1 I1 111P1 �T�� lllllll�ll�ll��lllll�l_.1-� _ ��11�11111 Ill hll���1 ■ 111ll� A2.101111111011111111011. WEST ENTRY - SOFFIT PLAN 3/32" =1'-0" EXIST. COLUMN FACE OF BLDG. EXIST. SOFFIT FRAMING PAINT SOFFIT BLACK INSTALL %" METAL FURRING STRIPS @ 24" O.C. TYP. PERP. TO NEW WOOD SLATS. NEW IPE WOOD SLATS (MATCH EXIST. SIZE AND FINISH) ATTACH TO FURRING WITH CONCEALED FASTENERS NEW IPE SOFFIT AND LIGHTING 0 0 Project Name: - Fixture Type: - Model No: - Lamp Info: APPLICATION Square aperture, high lumen medium distribution downlight is suitable for commercial, retail and institutional applications that require an energy saving, long life LED lamp source, high lumen output and excellent color rendering characteristics. PRODUCT DATA REFLECTOR: The parabolic reflector redirects spill light from the lamp, and elimi- nates high angle glare. A one half-inch overlap flange is standard. Supplied standard with Haze Alzak, other reflector finishes are available in order to provide maximum flexibility to the designer. HOUSING: Heavy gauge steel housing provides a secure mounting platform for the electrical components and protects the optical assembly. Standard plaster flange allows one inch ceiling thickness. LED components are accessible from below. MOUNTING: Universal Mounting brackets adjust vertically 5.5" and accepts C -channel or rigid bars (see optional accessories). ELECTRICAL: 120 to 277 VAC, 50-60 Hz. JUNCTION BOX: Heavy gauge galvanized junction box pre -wired with grounding pigtail. Easy access covers. Multiple conduit knockouts listed for through branch circuit wiring. LED MODULE & DRIVER: Bridgelux RS Series LED module and driver. CRI = 80. Power: 7000L = 90W, 5000L = 73W, 4000L = 58W, 3000L = 51W. HEAT MANAGEMENT: Engineered heat sink features patented Synjet module that circulates air for optimum heat management of the LED engine. DIMMING: Standard product is compatible with 0-10 volt dimming controls. Additional options available. • Expected lamp life to be 50,000 hours with 70% lumen maintenance when ambient temperatures do not exceed 45°C. Lower ambient temperatures yield longer lamp life. cas Intertek For Damp Location Architectural Series CALIBER® §LIGHTING 5 Year Warranty "Synjet° active cooling module for optimum thermal management" Optional suspended, decorative lens (IC4) �, r C r - 7.42" pi -4.5"x4.5" -1 5.7"x 5.7" Rough Opening 5.13" x 5.13" Catalog #: 4SQLB Example: 4SQLB404KN Fixture Series Lu ens Color Temp Beam Dist Dimming Optional Accessories Hanger Bars (set of 2) • 101782 = #520 Caddy Bars ❑ 9127 = 27" C -Channel ❑ 9152 = 52" C -Channel • 27BH = 27" Solid Bar ❑ 24CBH = 24" one-piece B -Line C -Channel hanger bar ❑ 26UBH = interlocking hanger bars expand to 26" Fixture: Type: Project: CIA TAJIA/A V® / 4SQLB Example: 4SQLBHAZPF Trim Trim Finish poli ge 4SQLB - Downlight Reflector IC4 Suspended Decorative Glass Lens HAZPF — Haze Alzak For white painted flange, drop "PF" from Catalog #. For other finishes, consult reflector section. Additional Options EM = Emergency Power Pack 0 X = Provision for glass lens (IC4) Manufactured and tested to UL#1598 and CSA standards. Note: Suitable for damp location. Fixtures are not designedfor direct contact with insulation. All Pathway® products meet or exceed requirements as established by the National Electrical Code. Specifications subject to change without notice. Alzate is a registered trademark of Alcoa. I A ■ WWII AIMI ■ P/9e Lig/ii/#tg ZOdlrce Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591 voice 800.342.0592 • fax 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com 05 LIGHT FIXTURE NO SCALE 0 0 i 11111111111111111111111111111111111 11111111111111 4> Iii.IliuhhhhhuIlIl.1111111I • REVIEWED FOR ODE COMPLIANCE APPROVED Tr NOV 07 2011 RECEIVED CITY OF TUKWILA NOV 0 6 2011 PERMIT CENTER bn% ox74 I] ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com a) Co Cr) W V c � /O a) V / E a) 0 o CD 0 w a) -o a) Tukwila, Wa 98188 CONSULTANT STAMP 6378 REGISTERED AR HITECT G STATE OF WASH REVISIONS: PLAN REVIEW COMMENTS 11/6/2107 PHASE/DELIVERABLE PERMIT SET DATE: DRAWN: PROJECT NO: 10/2/2017 PE 17-026 APPROVED: SHEET TITLE: SOFFIT PLAN SECTION / DETAILS SHEET NO: PE A2.1 N = 28° M = 48° blank = 0-10V 10% D8 = 01OV1% DMX = DMX 10%* DMX8 = DMX 1%* *interfaced through 0-10V driver 4K = 4000K 70 0L Ibu 4SQLB 35K = 3500K 3K = 3000K 27K = 2700K = 9UOUOuL 40 = 4000E 30 = 3000L W = 74° Optional Accessories Hanger Bars (set of 2) • 101782 = #520 Caddy Bars ❑ 9127 = 27" C -Channel ❑ 9152 = 52" C -Channel • 27BH = 27" Solid Bar ❑ 24CBH = 24" one-piece B -Line C -Channel hanger bar ❑ 26UBH = interlocking hanger bars expand to 26" Fixture: Type: Project: CIA TAJIA/A V® / 4SQLB Example: 4SQLBHAZPF Trim Trim Finish poli ge 4SQLB - Downlight Reflector IC4 Suspended Decorative Glass Lens HAZPF — Haze Alzak For white painted flange, drop "PF" from Catalog #. For other finishes, consult reflector section. Additional Options EM = Emergency Power Pack 0 X = Provision for glass lens (IC4) Manufactured and tested to UL#1598 and CSA standards. Note: Suitable for damp location. Fixtures are not designedfor direct contact with insulation. All Pathway® products meet or exceed requirements as established by the National Electrical Code. Specifications subject to change without notice. Alzate is a registered trademark of Alcoa. I A ■ WWII AIMI ■ P/9e Lig/ii/#tg ZOdlrce Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591 voice 800.342.0592 • fax 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com 05 LIGHT FIXTURE NO SCALE 0 0 i 11111111111111111111111111111111111 11111111111111 4> Iii.IliuhhhhhuIlIl.1111111I • REVIEWED FOR ODE COMPLIANCE APPROVED Tr NOV 07 2011 RECEIVED CITY OF TUKWILA NOV 0 6 2011 PERMIT CENTER bn% ox74 I] ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com a) Co Cr) W V c � /O a) V / E a) 0 o CD 0 w a) -o a) Tukwila, Wa 98188 CONSULTANT STAMP 6378 REGISTERED AR HITECT G STATE OF WASH REVISIONS: PLAN REVIEW COMMENTS 11/6/2107 PHASE/DELIVERABLE PERMIT SET DATE: DRAWN: PROJECT NO: 10/2/2017 PE 17-026 APPROVED: SHEET TITLE: SOFFIT PLAN SECTION / DETAILS SHEET NO: PE A2.1