Permit D17-0279 - BOEING #9-08 - REMODEL ENTRY SPACE
BOEING #9-08 9725 E MARGINAL WAY S D17-0279 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 5624201032 Permit Number: D17-0279 9725 E MARGINAL WAY S BLDG 9-008 Issue Date: 11/27/2017 Permit Expires On: 5/26/2018 Project Name: BOEING #+9-08 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH PO BOX 3707 MC 46-88 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Phone: (253) 350-5522 Phone: (312) 544-2535 Expiration Date: 1/18/2019 DESCRIPTION OF WORK: REMODEL 1,200 SQ FT ENTRY ROOM INTO 3 SEPARATE SPACES. SEE COVER SHEET Project Valuation: $197,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $4,176.94 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes:. Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: ll I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: If /`/\4 C i tiV) Lf Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 2:. Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 3: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 4: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 8: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 6: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 5: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 10: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 9: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 7: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 11: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 13: ***BUILDING PERMIT CONDITIONS*** 14: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 15: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 16: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 17: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 18: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 19: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 20: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 21: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 22: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 23: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 24: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 25: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 26: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 27: ***BUILDING PERMIT CONDITIONS*** 28: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 29: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 30: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 31: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 32: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 33: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 34: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 35: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 36: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 37: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 38: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 39: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 40: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD 4046 SI-EPDXY/EXP CONC 0406 SUSPENDED CEILING CITY OF TUKi'rLA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htty://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: (D-1 .� — 17 Date Application Expires: 3-4 Q (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 9725 E. marginal way s Tenant Name: Boeing co 5624201032 Suite Number: 9-08 PROPERTY OWNER Name: John Murdoch /Mark Clement*- Boeing co. Name: The Boeing co. John Murdoch City: Seattle State: Wa Zip: 98124 Address: PO Box 3707 MC 46-88 Email: John.s.murdoch@boeing.com City: Seattle State: Wa zip: 98038 CONTACT PERSON — person receiving all project communication Name: John Murdoch /Mark Clement*- Boeing co. Address: Po box 3707 MC 46-88 City: Seattle State: Wa Zip: 98124 Phone: (253) 350-5522 Fax: (206) 617-2944 Email: John.s.murdoch@boeing.com GENERAL CONTRACTOR INFORMATION Company Name: The Boeing company- John Murdoch Address: PO Box 3707 MC 46-88 City: Seattle State: WA Zip: 98124 Phone: (253) 350-5522 Fax: Contr Reg No.: BOEINC*294ML Exp Date: 01/18/2019 Tukwila Business License No.: H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 • bh • New Tenant: ❑ Floor: Yes El ..No 1 ARCHITECT OF RECORD Name: John Murdoch Company Name: Sins & Hill City: Seattle State: WA Zip: 98124 Architect Name: Dave Boileau Address: 4815 Center Street City: Tacoma State: WA Zip: 98409 Phone: (253) 474-9449 Fax: Email: sitts-hill-engineers.com ENGINEER OF RECORD Name: John Murdoch Company Name: Sits and Hill City: Seattle State: WA Zip: 98124 Engineer Name: Brent Leslie Address: 4815 Center Street City: Tacoma State: WA Zip: 98409 Phone: (253) 474-9449 Fax: Email: sitts-hill-engineers.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: John Murdoch Address: PO. Box 3707 mc 46-88 City: Seattle State: WA Zip: 98124 Page 1 of 4 BUILDING PERMIT INFORMATILyari 206-431-3670 Valuation of Project (contractor's bid price): $ 197,000 Describe the scope of work (please provide detailed information): Remodel 1,200 sq ft entry room into 3 separate spaces SEE COVER SI -WET Will there be new rack storage? ❑ Yes Existing Building Valuation: $ 1.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: J • Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Q Sprinklers Z Automatic Fire Alarm ❑ None Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes l No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Fermit Application Revised - 8.9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,200 1,200 TYPE 2 B 2"dFloor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: J • Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Q Sprinklers Z Automatic Fire Alarm ❑ None Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes l No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Fermit Application Revised - 8.9-I I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFOi IATION — 206-433-0179 Scope of Work (please provide detailed. information): NA Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ ...Water District #125 O .. Highline ❑ ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided 0 .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond El .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way El ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards 0 ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance 0 .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank El .. Curb Cut ❑ .. Pavement Cut 0 .. Looped Fire Line 0 ...Permanent Water Meter Size... WO # ❑ .. Grease Interceptor 0 .. Channelization ❑ .. Trench Excavation 0 .. Utility Undergrounding ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private El ❑ ...Water Main Extension Public ❑ Private El FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H.\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZZEED AGENT: Signature: ../44PAA Print Name: Mark Clement Mailing Address: same as applicant Date: 10/13/2017 Day Telephone: (206) 617-2944 . City H: ApplicationsTorms-Applications On Line \201 I ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID $2,581.65 PermitTRAK D17-0279 Address: 9725 E MARGINAL WAY S BLDG 9-008 Apn: 5624201032 $2,581.65 Credit Card Fee $75.19 Credit Card Fee R000.369.908.00.00 0.00 $75.19 DEVELOPMENT $2,387.32 PERMIT FEE R000.322.100.00.00 0.00 $2,382.82 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $119.14 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12871 R000.322.900.04.00 0.00 $119.14 $2,581.65 Date Paid: Monday, November 27, 2017 Paid By: MARK CLEMENT Pay Method: CREDIT CARD 068141 Printed: Monday, November 27, 2017 2:02 PM 1 of 1 CIIIWYSTEMS DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK : PAID $1,595.29 D17-0279 Address: 9725 E MARGINAL WAY 5 BLDG 9-008 Apn: 5624201032 $1,595.29 Credit Card Fee $46.46 Credit Card Fee R000.369.908.00.00 0.00 $46.46 DEVELOPMENT $1,548.83 PLAN CHECK FEE R000.345.830.00.00 0.00 TOTAL FEES PAID BY RECEIPT: R12571 $1,548.83 $1,595.29 Date Paid: Friday, October 13, 2017 Paid By: MARK CLEMENT Pay Method: CREDIT CARD 076166 Printed: Friday, October 13, 2017 3:02 PM 1 of 1 C37SYSTEMS INSPECTION RECORD Retain a copy with permit JD17-0279 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: R::)0 e) Ty e of Inspection: 1A, 1 C� 1 F t4&L. Address: 125,liptlyninct.L. WAy 7 C?.—A98 .— 8pecial Instructions: C f5f)€ t 1x'1 49 -- Og r � Date Wanted;�-' ap..mm. � Q' Requester: r i Phone No: .2S-..3 -.39 -1856 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: f-6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1'r7-©79 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: r 72, ai ig/R )L Date Called: s ) Special Instructions: Date Wanted:�t fU ,TI�'_.�}_'l p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0.11<-s ,.foa L=iM- - 65K - ' 7 W - R Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P)7 -Q2.77 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �[s A04/6,--9: 3 Type of Inspection: ,�R�tirl®N� Address: Date Called: Special Instructions: I%/�.ywfL &41-L.- Gal -‘4,17 'A- Date Wanted' '-,7-/7 a rn Requester: Phone No: v...06,..,..7.7....6/7 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: fes- '111/2--/ Inspector: Date: /%R-/7 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila DING DIVISION High Performance Product Solutions RECEIVED CITY OF TUKWILA NOV 09 2017 PERMIT CENTER CORREC,TIOM LTR# U i`1-07 9 Tate® Access Floors (ConCore Panels page 3 All Steel Panels page 4 Steel System Understructure page 5 Woodcore System page 6 Aluminum System page 7 2 BASF North American Headquarters, Florham Park NJ, 325,000 ft2, LEED Platinum (ConCore Panels ConCore Access Floor panels are epoxy coated unitized shells consisting of a flat steel top sheet welded to a formed steel bottom sheet filled with a highly controlled mixture of lightweight cement. Manufactured to exacting tolerances, these non-combustible, rigid, solid panels deliver the ultimate in strength, durability, and acoustic performance. Applications With six standard load performance grades and an extensive selection of understructure supports and floor finishes, it is recommended that you visit our website: www.tateinc.com for further information on product details, finish options, architectural details, system specifications, and selecting the proper panel to meet the needs of your specific application. Champaign Public Library, Champaign, IL, 122,000 ft2 ConCore° Performance Selection Chart Value Act Capital, San Francisco, CA, 10,000 ft2 System Performance Criteria* (Tested on Actual Understructure) Static Loads ,i Rolling Loads System Design r Minimum S•afety 10 10,000 Weight Loads' 1 Ultimate Loads Factors', Panel Understructure lbs/ft2 lbs ! lbs min 2.0 Passes lbs Passes lbs Impact Loads lbs ConCore° 1000 ConCore° 1250 ConCore° 1500 PosiLocl 8.0 (39kg/m2) 1000 (4.4kN) ' 2000 (8.9kN) ,' PASS + + -+ t PosiLock°+ 8.5 (42kg/m2) + 1250 (5.6kN) + 2500 (11.1 kN) PASS PosiLock° 9.0 (44kg/m2) t 1500 (6.7kN) 3000 (13.3kN) PASS • 800 (3.6kN) 1125 (5.0kN) + 1250 (5.6kN) ConCore° 1000 I Bolted Stringer + 9.0 (44kg/m2) + 1000 (4.4kN) + 2000 (8.9kN) + PASS + 800 (3.6kN) ConCore° 1250 Bolted Stringer 10.0 (49kg/m2) 1250 (5.6kN) 12500 (11.1 kN) PASS 1000 (4.4kN) ConCore° 1500 I Bolted Stringer + 10.5 (51 kg/m2) 1500 (6.7kN) t 3000 (13.3kN) + PASS + 1250 (5.6kN) t T _ ConCore° 2000 t Bolted Stringer ;11.5 (56kg/m2) 2000 (8.9kN) t 4000 (17.8kN) PASS +1500 (6.7kN) r 1250 (5.6kN) 200 (91kg) ConCore° 2500 IBolted Stringer + 12.0 (59kg/m2) +2500 (11.1 kN) t 5000 (22.2kN) + PASS F 2000 (8.9kN) 2000 (8.9kN) +200 (91kg) ConCore° 3000 Bolted Stringer 13.0 (63kg/m2) 3000 (13.3kN) : 6000 (26.7kN) PASS 2700 (12.0kN) 2400 (10.7kN) 200 (91kg) 600 (2.7kN) 150 (68kg) 875 (3.9kN) 150 (68kg) 1000 (4.4kN) 150 (68kg) 600 (2.7kN) r 150 (68kg) - 800 (3.6kN) + 150 (68kg) 1000 (4.4kN) 150 (68kg) All tests are performed using CISCA's Recommended Test Procedures for Access Floors with the exception of Design Load 1. System Design Load is based on permanent set 5 0.010" and is verified by loading panels in accordance with the CISCA concentrated load method but with panels installed on actual understructure instead of steel blocks. (Testing on blocks does not represent performance of an actual installation.) Ultimate, Rolling, and Impact Load tests are performed using CISCA Test Procedures. 2. Safety Factor is Ultimate Load divided by Design Load. 3 Tate All Steel Panels All Steel Access Floor panels are epoxy coated unitized shells consisting of a flat steel top sheet welded to a formed steel bottom sheet. Manufactured to exacting tolerances, these non-combustible rigid, solid panels deliver the ultimate in strength and durability with the convenience of lightweight construction. Panel Features • The safe working load or design load for the panels is equal to the concentrated load • Lightweight for ease of handling • Excellent grounding and electrical continuity • Full range of factory applied finishes • Completely non-combustible • Interchangeable with ConCore, Perforated, and Grate panels • Available in 24" and 60cm sizes Applications With three standard load performance grades and complete interchangeability with ConCore, Perforated and Grate airflow panels, these panels coupled with an extensive selection of understructure supports and floor finishes are suitable for a wide range of applications from typical data/computer centers to telecommunication rooms, mission critical facilities, electronic assembly areas, and other general purpose equipment rooms. Starlight Casino, Queensborough, BC, 100,000 ft2 All Steel Performance Selection Chart Engberg Anderson Design Partnership, Milwaukee, WI, 18,800 ft2, LEED Gold System Performance Criteria* (Tested on Actual Understructure) Panel Understructure System Weight lbs/ft2 Static Loads Rolling Loads Design Loads' lbs Minimum ,Ultimate Loads lbs Safety Factors' min 2.0 �i--- 10 Passes lbs 10,000 Passes lbs Impact Loads lbs All Steel 1000 All Steel 1250 All Steel 1500 Bolted Stringer Bolted Stringer Bolted Stringer 6.0 (29kg/m2) 1000 (4.4kN) 7.0 (34kg/m2) 1250 (5.6kN) 8.5 (42kg/m2) 1500 (6.7kN) 2000 (8.9kN) 2500 (11.1 kN) 3000 (13.3kN) PASS PASS PASS 400 (1.8kN) 400 (1.8kN) 500 (2.2kN) 500 (2.2kN) 600 (2.7kN) 600 (2.7kN) 150 (68kg) 150 (68kg) 150 (68kg) All tests are performed using C/SCA's Recommended Test Procedures for Access Floors with the exception of Design Load 1. System Design Load is based on permanent set s 0.010" and is verified by loading panels in accordance with the CISCA concentrated load method but with panels installed on actual understructure instead of steel blocks. (Testing on blocks does not represent performance of an actual installation.) Ultimate, Rolling, and Impact Load tests are performed using CISCA Test Procedures. 2. Safety Factor is Ultimate Load divided by Design Load. ACCESS FLOOR PRODUCTS 4 Understructure Systems for ConCore and All Steel Systems PosiLock® Understructure Features • PosiLock® design provides self -engagement and positioning of floor panels. • Self -capturing fastener remains within the panel - will not get lost. • Steel pedestal head provides maximum strength. • Pedestal nut provides anti -vibration and locking features. • Seismic force -resistant pedestals are available that limit or eliminate the need for special bracing. • Typical floor heights from 6"-16" (15cm-40cm). Low Finished Floor Height PosiLock® Understructure Features • Available in floor heights from 2'/e" to 4" (7cm-10cm). • PosiLock® design provides self -engagement and positioning of floor panels. • 27/8" (7cm) finished floor height is ideal for renovation applications while providing enough space under the floor to allow for easy cable management. • Excellent for classroom renovations and the creation of training areas. • Easily levels uneven floors. Panel engagement feature viewed from underside PosiLock® pedestal for low floor height systems Bolted Stringer Understructure Features • Designed for computer rooms, data centers, industrial applications, and heavy rolling load areas. • Allows floors to be built over 24" (60cm) high. • Panels can be gravity -held in understructure for fast removal and replacement. • Stringers provide lateral resistance to heavy rolling loads and seismic loading. • Seismic force -resistant pedestals are available that limit or eliminate the need for special bracing. • Typical floor heights from 12"-36" (30cm-90cm). Hot Dipped Galvanized Pedestals Seismic Pedestals Understructure Features • Available with standard and fillet welded base assembly. • Steel pedestal head provides optimum strength. • Seismic force -resistant pedestals are available that limit or eliminate the need for special bracing. • Vertical supports ranging from 17 gauge 7/8" (2.2cm) galvanized tubing to Schedule 40 pipe. • Pedestals can accommodate finished floor heights over 36" (90cm). • Easily levels uneven floors. 5 Tate ONIMV6G 31V3S ION OG 3 3 Er 0 D(03 UJ09 laund aJojuoj. Er o < 1!n�aQ Qd3 land wo09 aJo3uo3 3 ICCN 3000 CCN 2500 ICON 2000 x--) n z tzil i CCN 1250 ICCN 1000 PANEL TYPE 35,O5mm-36,07mm 34,80mm-35,81mm 34.29mm-35.31mm C.).) 33,27mm-34.29mm 33,02mm-34,04mm DIM "B" CO 3 :3 I CJ CO 0 3 3 41,66mm-42,67mm 41,40mm-42,42mm 40.89mm-41,91mm 4. 39,88mm-40,89mm 39,62mm-40,64mm DIM "C" R w 3 3 .1 i, -P 0 3 3 Tate ConCore®: CC1250 Panel -24" • Optional PosiTile holes (4 ea) Welded assembly at domes and perimeter Full hard cold rolled steel top sheet 0 Draw quality steel bottom pan with structural dome design Cementitious core material 0 O (4 ea) PosiLock holes 0 Painted finish 0 TOP VIEW Integral shape pocket design and locating tab for positive lateral retention and location with or without screws CORNER DETAIL SPECIFICATIONS General information • Panel weight : 8.0 lbs./ft2 bare. • All steel welded construction filled internally with a cementitious core material. • Protected from corrosion by an epoxy paint finish. • Class A flame spread rating. • Non-combustible material. UNDERSTRUCTURE OPTIONS ❑ Freestanding 0 Posilock O 2' Bolted Stringer 0 4' Bolted Stringer • COVERING OPTIONS Tile factory laminated with integral trim edge ❑ 1/8" HPL (Color) O 1/16" HPL (Color) ❑ 1/8" Conductive HPL (Color) ❑ 1/16" Conductive HPL (Color) For additional laminate options contact Inside Sales Bare Painted Panel Options ❑ Bare Painted Finish to accept carpet tile application ❑ Bare Painted Finish to accept PosiTile application Bare Panel 1-3/8" deep 1-5/8' deep at corners Laminated Panel With Integral Trim i.� 1-5/8" deep 1 1-3/8" deep at corners System Performance Criteria (Tested on Actual Understructure)* System Type SYSTEM WEIGHT STATIC LOADS ROLLING LOADS IMPACT LOADS Panel Understructure Design Ultimate Loads Safety Factor Loads 10 Passes 10,000 Passes ConCore CC1250-24" Posilock 8.5 lbs / ft2 41 kg / m2 1250 lbs Min. 25001bs Mni. 2 567 kg Min. 1134kg 1125 lbs 875 lbs 510 kg 397 kg 150 lbs 68 kg Bolted Stringer 10.0 lbs / ft2 49 kg / m2 1250 lbs Min. 25001bs Min. 2 567 kg Min. 1134kg 1000 lbs 800 lbs 454 kg 363 kg 150 lbs 68 kg 1. System Design Load is based on permanent set 5 0.010" and is verified by loading panels in accordance with the CISCA concentrated load method but with panels installed on actual understructure instead of steel blocks. (Testing on blocks does not represent performance of an actual installation.) Ultimate, Rolling, and Impact Load tests are performed using CISCA test procedures. 2. Safety Factor is Ultimate Load divided by Design Load. Tate Access Floors, Inc. 7510 Montevideo Road Jessup, MD 20794 Tel (410) 799-4200 Fax (410) 799-4207 © 2008 Tate Access Floors, Inc. R 7/2015 Interior Lighting Summary - Building Area Method LTG -INT -BLD 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Fill this line out on LGT-SUM Date 11/8/2017 Lighting Alterations, Renovations & Building Additions C) Less than 60% @) 60% or more 0 Stand alone C) Addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they maybe combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, use LTG -INT -SPACE form. F - .,•.•.• e.anartment Use Watts/ Fixture REVIEWED FOR CODE COMPLIANCE APPROVED NOV2 1 1 lel M 2017 City of Tu kwi Ia BUILDING DIVISION Space -By -Space method selected. Use LTG -INT -SPACE form. Building Area* Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Office 6" DOWNLIGHT - LED - 6 0.90 730 657 'K 1 "Iii.1 n. ------- A 14I -ml M * Select Table C405.5.2(1) Building Area from drop down menu. Total 730 6 Li l Space -By -Space method selected. Use LTG -INT -SPACE form. Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Office 1E12 2' X 4' LED 15 27 405 Office 1E12 6" DOWNLIGHT - LED - 6 33 195 'K 1 "Iii.1 n. ------- A 14I -ml CORREC 1 101\ TRIE * Select Table C405.5.2(1) Building Area from drop down menu. ** Include existing to remain lighting and exempt lighting equipment per notes below. Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Office 657 600 COMPLIES 'K 1 "Iii.1 n. ------- A 14I -ml Total Notes: 657 600 D CITY OF TUKWILA 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading watta�b�p�, 2��7 Building Area types is not allowed under the Building Area Method compliance path. UU c� 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast typo i c de For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. r MIT. CENTER 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. City of Tukwila Building Division REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila 3LC Building Permit Number: D17-0279 BUILDING DIVISION Special Insj ectmn and Testing Agreement Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 BEFORE A PERMIT CAN BE ISSUED: The owner, engineer, or architect of record acting as the owner's agent, shall complete two (2) copies of this agreement, the Special Inspections Qualification Form and the attached Structural Tests and Inspections Schedule, including the required acknowledgments. A pre -construction conference with the parties involved may be required to review the special inspection requirements and procedures. APPROVAL OF SPECIAL INSPECTORS: Each special inspector shall be approved by the Building Division, prior to performing any duties. Each special inspector shall complete the enclosed Special Inspector Qualification Form and submit his/her qualification to the Building Division and is subject to a personal interview for pre -qualification. Special inspectors shall display approved identification as stipulated by the Building Division, when performing the function of a special inspector. Special inspection and testing shall meet the minimum requirements of I.B.C. Section 1704.2.1. The following conditions are also applicable: A. Duties and Responsibilities of the Project Owner: 1. Funding: The project owner, the engineer, or architect of record, acting as the owner's agent is responsible for funding special inspection services (See I.B.C., Section 1704.2) 2. Employment: The project owner/agent hereby, agrees that he/she shall not terminate his/her contract for special inspection services; with the below named firm until he/she has obtained the services of another inspection firm and submitted a new Special Inspection Agreement Form for approval and accepted by the building official. B. Contractor Responsibilities: 1. Notify the Special Inspector: The contractor is responsible for notifying the special inspector or agency regarding individual inspections for items listed on the attached schedule and as noted on the Building Division approved (stamped) plan(s). Adequate notice shall be provided so that the special inspector has time to become familiar with the project. 2. Provide Access to Approved Plan(s): The contractor is responsible for providing the special inspector access to the approved (stamped) plan(s) as the job -site. 3. Retain Special Inspection Records: The contractor is also responsible for retaining at the job - site all special inspection records submitted by the special inspector and providing these records for review by the Building Division's approved (stamped) plan(s) for additional inspections or testing requirements that may be noted. 4. Samples: Only the special inspection agency or materials engineering laboratory elyO CEIVED permitted to take laboratory samples and transport them to the facility. TUKWILA NUV 0 9 2017 CORRECTION PERMIT4CENTER LTR# o,27? City of Tukwila Building Division Building Permit Number: D17-0279 C. Duties and Responsibilities of the Special Inspector: 1. Observe Work: The special inspector shall observe the work for conformance with the Building Division approved (stamped) design drawings and specifications and applicable workmanship provisions of the I.B.C. 2. Report Nonconforming Items: The special inspector shall bring nonconforming items to the immediate attention of the contractor and note all such items in the daily report. If any item is not resolved in a timely manner or is about to be incorporated in the work, the special inspector shall immediately notify the building official by telephone or in person, notify the engineer or architect, and post a discrepancy notice. 3. Furnish Daily Reports: On request each special inspector shall complete and sign both the Special Inspection Record and the Daily Report Form for each day's inspections to remain at the job -site with the contractor for review by the Building Division's. inspector. 4. Furnish Weekly Reports: The special inspector or inspection agency shall furnish weekly reports of tests and inspections directly to the building official, project engineer, architect, and other as designated. These reports must include the following: a. Description of daily inspections and tests made with applicable locations; b. Listing of all nonconforming items; c. Report on how nonconforming items were resolved or unresolved as applicable; and d. Itemized changes authorized by the architect, engineer, and building department if not included in the conformance items. 5. Furnish Final Report: The special inspector or inspection agency shall submittal a final report the building official stating that all items requiring special inspection and testing were fulfilled and reported and, to the best of his/her knowledge, in conformance with the approved (stamped) design drawings, specifications, approved change orders and the applicable workmanship provisions of the I.B.C. Items not in conformance, unresolved items or any discrepancies in inspection coverage (i.e. missed inspections, periodic inspections when continuous was required, etc.) should be specifically itemized in this report. D. Building Division Responsibilities: 1. Approved Special Inspectors/Inspections: The building official shall approve all special inspectors and special inspection requirements. 2. Monitor Special Inspectors/Inspection: Work requiring special inspection and the performance of special inspectors, shall by monitored by the Building Division's inspector. His/her approval must be obtained prior to placement of concrete or other similar activities in addition to that of the special inspector. 3. Issue Certificate of Occupancy: The building official will only issue a certificate of occupancy after all special inspection reports and the final report have been submitted and approved. 5 City of Tukwila Building Division Building Permit Number: D17-0279 ACKNOWLEDGMENTS I have read and agree to comply with the terms and conditions of this agreement. Owner: Date: Contractor: Date: Special Inspector/Inspection A nc : Date: Project Engineer/Architect:4a9 Date: 11/06/2017 ACCEPTED FOR THE BUILDING DEPARTMENT By: Date: 6 City of Tukwila Building Division Building Permit Number: E17-0279 Special Inspector Qualification Form Each special inspector making inspections for any inspecting/testing agency shall complete this form and enclose a work experience resume for the past five (5) years. Inspector Information: Name: Mayes Testing Engineers, Inc. Address: 10029 South Tacoma Way, Suite E-2 City, State, Zip: Tacoma, WA 98499 Office Phone: (253) 584-3720 Cell Phone: Inspection Classification: Current ICC and/or WABO Number(s): Expiration Date: Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 STATEMENT OF UNDERSTANDING I, hereby affirm that I have been employed by: (Agency/Firm) (Address) To perform special inspection at above stated project and that I am aware that in performing this inspection, I am acting as an agent for the City of Tukwila and I am responsible to the building official. I am aware that my duties include compliance with the approved plan(s), specifications, the I.B.C. and recognized construction practices, which do not conflict with any of the aforementioned documents. I will submit written reports to the building official as required. Signature: Date: 7 City of Tukwila Building Division Building Permit Number: D17-0279 Special Inspection and Testing Schedule Testing/Inspection Agency/Special Inspector: Mayes Testing Engineers, Inc. Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 REINFORCED CONCRETE, GUNITE, GROUT & MORTAR: Concrete Gunite Grout Mortar PRECAST / PRESTRESSED CONCRETE: Concrete Gunite Grout Mortar Aggregate Tests Reinforcing Tests Mix Designs Reinforcing Placements Batch PIant Inspection Inspect Placing Cast Samples Pick-up Samples Compression Tests PRECAST / PRESTRESSED CONCRETE: Concrete Gunite Grout Mortar 8 Aggregate Tests Reinforcing Tests Tendon Tests Mix Designs Reinforcing Placements Insert Placement Concrete Batching Concrete Placement Installation Inspection Cast Samples Pick-up Samples Compression Tests 8 City of Tukwila Building Division STRUCTURAL STEEL / WELDING: Sample & Test (list specific members below) Shop Material Identification Welding Inspection [ 1 Shop [ ] Field Ultrasonic Inspection [ 1 Shop [ ] Field High -Strength Bolting Inspection [ ] Shop [ ] Field [ ] A325 [ ] A490 [ ] N [ ] X [ ] F Metal Deck Welding Inspection Reinforcing Steel Welding Metal Stud Welding Inspection Concrete Insert Welding Inspection MASONRY: Special Inspection Stresses Used Preliminary Acceptance Tents (Masonry Units, Wall Prisms) Subsequent Tests (Mortar, Grout, Field wall Prisms) Placement Inspection of Units Building Permit Number: D17-0279 FIREPROOFING: Placement Inspections Density Tests Thickness Tests Inspection Batching INSULATING CONCRETE: Sample & Test Placement Inspections Unit Weights FILL MATERIAL Acceptance Tests Placement Inspections Field Density STRUCTURAL WOOD: Shear Wall Nailing Inspection Inspection of Glu -lam Fab. Inspection of Truss Joist Fab. Sample and Test Components List all other additional of required inspections, conditions, tests, or special inspections here: Anchors installed in hardened concrete (raised floor pedestal anchors per Section A/A501) Form completed by: Brent Leslie, P.E., S.E. Telephone No: (253) 474-9449 Title: Sr. Vice President Date: 11/06/2017 9 City of Tukwila Building Division Building Permit Number: D 17-0279 APPENDIX A Special Inspection Forms, Schedules, and Agreements Special Inspectors Daily Report Special Inspection Weekly Report Discrepancy Notice Final Special Inspection Report 10 City of Tukwila Building Division Building Permit Number: D17-0279 Special Inspection and Daily Report Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 Inspection Type(s)/Coverage: [ ] Continuous [ ] Periodic Time Beginning Inspection: Time Ending Inspection: Describe Inspections Made, Including Locations: List Test Made: List Items Requiring Correction, Corrections of Previously Listed Items and Previous)/ Listed Uncorrected Items: List Changes to Approved Plan(s) Authorized by the Building Official and Architect or Engineer: Comments: To the best of my knowledge, the work I inspected was in accordance with the Building Division approved design drawings, specifications, and applicable workmanship provisions of the I.B.C. except as noted above. Signed: Date: Print Full Name: I.D. Number: (This report to remain at job -site with the contractor for review by the Building Division's inspector upon request.) 11 City of Tukwila Building Division Building Permit Number: D17-0279 Special Inspection Weekly Report Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 Inspection Type(s)/Coverage: [ ] Continuous [ ] Periodic Describe Inspections Made, Including Locations: List Test Made: Total Inspection Time Each Day: Date Hours List Items Requiring Correction, Corrections of Previously Listed Items and Previously Listed Uncorrected Items: List Changes to Approved Plan(s) Authorized by the Building Official and Architect or Engineer: Comments: To the best of my knowledge, the work I inspected was in accordance with the Building Division approved design drawings, specifications, and applicable workmanship provisions of the I.B.C. except as noted above. Signed: Date: Print Full Name: I.D. Number: cc: Building Division Engineer/Architect (This form to be distributed weekly when required by the Building division and/or engineer/architect.) 12 City of Tukwila Building Division Building Permit Number: D117-0279 Discrepancy Notice Project Name: Building 9-08 Lobby Renovation Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 Area Inspected: Type of Inspection: Special Inspector: Laboratory: Notice Delivered to: [ ] Contractor Date/Time: [ ] Engineer/Architect Date/Time: [ ] Building Division Date/Time: Make the following corrections and secure inspection approval prior to proceeding with this phase of the work: Contractor's Response: [ ] Repair or Replace in Accordance with Approved (stamped) Plan(s) and Specifications [ ] Modification Evaluation Signed: Date: COMPLETED AND APPROVED CONTRACTOR: DATE: INSPECTOR: DATE: DO NOT REMOVE THIS NOTICE Contact the City of Tukwila Building Division inspector upon issuance/posting at 206-431-3670 Post Adjacent to Building Permit Inspection Record Card FINAL SPECIAL INSPECTION REPORT 13 City of Tukwila Building Division To: City of Tukwila Department of Community Development Building Division 6300 Southcenter Blvd, Ste 100 Tukwila, WA 98188 206-431-3670 Attention: Jerry E. Hight, Building Official Re: Final Project Report Project Name: Building 9-08 Lobby Renovation Building Permit Number: D1.7-0279 Project Address: 9725 East Marginal Way South, Tukwila, Washington 98108 To Whom It May Concern: This is to certify that I performed special inspection on the following portions of the work at the above address, which required continuous inspection and which I was employed to inspect: Based upon my personal observation and written reports of this work, it is my judgment that the inspected work was performed, to the beset of my knowledge, in accordance with the approved (stamped) plan(s), specifications, and the applicable workmanship provisions of the International Building Code. Special Inspector's Signature: Print Full Name: Date: Registered Professional Signature*: *(Affix professional wet seal) cc: Client/Owner Architect/Engineer 14 CODE COMPLIANCE I In i.3%' D NOV 2 12017 City of Tukwila BUILDING DIVISION j ©'RECMVED Y OE'ARV:MLA OCT 13 2017 SITTS & HILL ENGINEERS, INC. Professional Engineers & Planners CIVIL, STRUCTURAL AND SURVEYING b - O23 9 Building 9-08 Renovate Lobby Entry 9725 East Marginal Way South Tukwila, WA 98108 CALCULATIONS PREPARED FOR THE BOEING COMPANY POST OFFICE BOX 3707, M/C 5E -4H SEATTLE, WA 98124 PREPARED BY Sitts & Hill Engineers, Inc. 4815 Center Street Tacoma, WA 98409 October 10, 2017 S & H Job Number: 18,001 SITTS & HILL ENGINEERS, INC. DESIGNED BRL DATE 10/10/2017 JOB 18,001 TACOMA, WASHINGTON (253) 474-9449 CHECKED BKL DATE 10/10%2017 PROJECT Building 9-08 Renovate Lobby Entry PAGE 1 CALCULATION INDEX BASIS SEISMIC ANALYSIS RAISED FLOOR SYSTEM ANCHORAGE 1 2 3 -4 5 - 22 P:\18000\18001 \Calculations\Structural\JPV-18001.xlsm 7 C 0 0 0 0 SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT Building 9-08 Renovate Lobby Entry BASIS FOR DESIGN DESIGNED BRL DATE 10/10/2017 JOB 18,001 CHECKED BKL DATE 10/10/2017 PAGE 2 BUILDING CODE: 2015 Edition of the International Building Code with State of Washington and City of Tukwila amendments shall be used and supplemented with ASCE 7-10. RISK CATEGORY: II. GRAVITY LOADS: Floor Live Load = 100 psf (reducible). Partition Load = 8 psf (for seismic only). LATERAL LOAD CRITERIA: CONCRETE: Wind Speed = Interior Structure. Seismic Site Class: D. Seismic Design Category: D. Minimum compressive strength of concrete shall be 3,000 psi. 2 P:\18000\18001 \Calculations\Structural\JPV-18001.xlsm 10/9/2017 Design Maps Summary Report usGs Design Maps Summary Report User -Specified Input Report Title 9-08 Lobby Mon October 9, 2017 23:35:18 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.51745°N, 122.30236°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS—Provided Output Ss = 1.517 g Sl = 0.575 g SMS = 1.517 g SMI = 0.862 g SDS = 1.011 g SDI = 0.575 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. NICER Response Spectrum 0.40 QBD 1_0I 127 LAO 1_9] I.D3 20I Period. T (see) CT, n u� Design Re -sponse Spthotrurn Period. T (see) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. https://earthquake.usgs.gov/cn2/designmaps/us/summary. php?template=minimal&latitude=47.517445&longitude=-122.302362&siteclass=3&riskcateg... 1/1 3 k-. L a SITTS & HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT i-OI DZ/ DESIGNED l DATE 10/n JOB I'O c CHECKED DATE SHEET OF 4 I I' - ----� I � � � � -�-i I �.,� 1" -pg ` - r 1 11x1 -12...p = 1 i c) 9 I O. a4.-ckh - -Co --A C ,c.;Y11,o\\�4- �-I ■ ►, I /1 C.) I --- ----1 II r 1 I- __J I 1 I J 13.E .-"1 1 4:21(1,_. "„1,1C..a - . I C.X !J CP I ems' " , 11 ,. T - L i - - -- --I-----_._._. - -_ 1 --�- 1 -- -- - - i H --1- ---, y - . J_J. I - -- - a - LL J -- - I I — H J - - 4 r-. SITTS Et HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT cl-U-5i DESIGNED 1 2..t . DATE 1.0/C1/1"--) JOB I'')C.r.)) CHECKED DATE SHEET OF 5 - --- -�n_._____J_14____ Its - _ ^ _R-- _ !"- w 11 l i --- �--- L; -� -- - -�- - -- - r ----- ' -- V rj �._ rile J_!`�..�`C�Y - lam„- PlIc r 1 j'I hl.,L.— I%,---) ear :., r•- e 4— J r te- 17y a F ; Q , 4...L--1 tis 1 t 111 1 -CP V '-C-,r4--- � IOW ✓ 1 1 \) I C/ 2SY ' ^„^" , ' lL��! �/ } j I- alp .t �JLS U..� v rll�.,.r) _ - r r TOT . CTS, I - -- -- -- —1J_ _ . --� -- — --- — — --- 1 ----_[-- --- A- _1 —-_--� Yys= _I- J41_ID --_-._- 1 -1 1 J _- _.-----_ f�__—_.---.---J _I_— __.----1—_ - --- i - -_� �- -- -- - { - -I - , - I 1-- I _�,. ls- - -1- -,- _l_I - __, - -- -- --- - -- -- I 1 - i— i - I o i .a - ._ �1 .Z- I c-�� '' 1 _I. a_...-_---.. . b0,._ -..,_1•S:71 _ J L. 5 SITTS Et HILL ENGINEERS, INC. TACOMA, WASHINGTON (253) 474-9449 PROJECT GI -O'% \f`f DESIGNED 4lL_1 DATE )P/C'l/n JOB DATE SHEET OF CHECKED rs o 1 41^x• - . `moi 0-0.„ 6 www.hilti.us Profis Anchor 2.7.3 Company: Specifier Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 1 Boeing 9-08 Lobby 10/9/2017 Specifiers comments: Load Case "A" 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Effective embedment depth: het,act = 2.000 in., hnom = 2.313 in. Material: Carbon Steel Evaluation Service Report: ESR -1917 Issued I Valid: 6/1/2016 15/1/2017 Proof: Design method ACI 318-14 / Mech. Stand-off installation: Anchor plate: Profile: Rectangular HSS (AISC); (L x W x T) = 0.875 in. x 0.875 in. x 0.062 in. Base material: cracked concrete, 3000, fce = 3000 psi; h = 4.000 in. Installation: Reinforcement: SAFEzE'T eb = 0.000 in. (no stand-off); t = 0.162 in. Ix x ly x t = 4.000 in. x 4.000 in. x 0.162 in.; (Recommended plate thickness: not calculated Seismic loads (cat. C, D, E, or F) Geometry [in.] & Loading [Ib, in.lb] hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Z 0 0 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 HMI AG, FL -9494 Schaan Hilti is a registered Trademark of Milti AG, Schaan 7 www.hilti.us MILIT I Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 2 Boeing 9-08 Lobby 10/9/2017 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 93 10 0 10 2 22 10 0 10 max. concrete compressive strain: 0.03 [%o] max. concrete compressive stress: 122 [psi] resulting tension force in (x/y)=(0.621/-0.621): 115 [Ib] resulting compression force in (x/y)=(0.621/1.747): 115 [Ib] 3 Tension load Load N18 [Ib] Capacity 4 Nn [Ib] 02 Y 0 Compression x Tensigo-� (�/1 1 Utilization DN = Nua/+ N„ Steel Strength* 93 4875 Pullout Strength* 93 1212 Concrete Breakout Strength** 115 1371 * anchor having the highest loading **anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value 4tNsa> Nua Variables Ase,N [in.2] 0.05 Calculations Nsa [Ib] 6500 refer to ICC -ES ESR -1917 ACI 318-14 Table 17.3.1.1 fut. [psi] 125000 Results Nsa [Ib] 4, steel l nonductile Nsa [Ib] Nua [Ib] 6500 0.750 1.000 4875 93 3.2 Pullout Strength rc Npn,l = Np,25o0 7v a 2500 4 Npn,f > Nua Variables fc [psi] 3000 Calculations 2500 1.095 Results N 05 [Ib] 2487 A.a 1.000 refer to ICC -ES ESR -1917 ACI 318-14 Table 17.3.1.1 Np,2500 [Ib] concrete 0.650 2270 2 8 9 4. seismic nonductile • N5 f [Ib] Nua [Ib] 0.750 1.000 1212 93 Status OK OK OK Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 www.hilti.us Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sibs & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 3 Boeing 9-08 Lobby 10/9/2017 3.3 Concrete Breakout Strength Ncbg = (ANco) W ec,N W ed,N w c,N W cp,N Nb 4) Ncbg > Nua ANC see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANcO = 9 hef 1 V ec,N V ed,N cp,N Nb 2 eN •5 1.0 1+3hef • =0.7+0.3(ca,min\51.0 `1.5hef J = MAX1/ca=min 1.5her < 1.0 = a' h:(5 Variables het [in.] ec1,N [in.] 2.000 0.621 Cac [in.] kc 4.375 17 Calculations ANc [in.2] ANco [in.2] 56.00 36.00 Results Ncbg [Ib] 4t concrete 2813 0.650 ec2,N [in.] 0.621 % a 1.000 ACI 318-14 Eq. (17.4.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.2.1c) ACI 318-14 Eq. (17.4.2.4) ACI 318-14 Eq. (17.4.2.5b) ACI 318-14 Eq. (17.4.2.7b) ACI 318-14 Eq. (17.4.2.2a) Comm,n [in.] W c,N 11.000 w ecl,N 0.829 fc [psi] 3000 w ec2,N 4) seismic 0.829 nonductile 1.000 W ed,N 1.000 0.750 1.000 Ncbg [Ib] 1371 W cp,N 1.000 Nua [Ib] 115 Nb [Ib] 2634 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 www.hilti.us 111111 ,-' Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sitts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 4 Boeing 9-08 Lobby 10/9/2017 4 Shear load Steel Strength* Steel failure (with lever arm)* Pryout Strength** Concrete edge failure in direction y+** Load Vua [Ib] 10 N/A 20 20 Capacity +14, [Ib] Utilization [iv = Vua/$ Vn * anchor having the highest loading **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value Vsteel Z Vua Variables Ase,v [in.2] 0.05 Calculations Vsa,eq [lb] 2255 Results Vsa eq [Ib] 2255 refer to ICC -ES ESR -1917 ACI 318-14 Table 17.3.1.1 futa [psi] 125000 4.2 Pryout Strength Y steel 0.650 w nonductile 1.000 4 ANc Vcpg — lc* [(ANc j W ec,N111 ed,N W c,N W cp,N Nb!11 Vcpg > Vua ANC see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANcO W ec,N W ed,N W cp,N Nb = 9 hef 1 2 eN < 1.0 1+3hef = 0.7 + 0.3 (Ca.min ) < 1.0 1.5hef = MAXrca_min 1.5hef1 < 1.0 `\ Cac Cac f =KXayTch,,5 Variables, kcp 1 Wc,N 1.000 Calculations AN, [in.2] 56.00 Results Vcpg [Ib] 4097 het [in.] 2.000 Cac [in.] 4.375 ANo0 [in.2] 36.00 4) concrete 0.700 1466 N/A 2868 2862 Vsa [lb] Vua [Ib] 1466 10 ACI 318-14 Eq. (17.5.3.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.2.1c) ACI 318-14 Eq. (17.4.2.4) ACI 318-14 Eq. (17.4.2.5b) ACI 318-14 Eq. (17.4.2.7b) ACI 318-14 Eq. (17.4.2.2a) ec1,N [in.] ec2,N [in.] cam., [in.] 0.000 0.000 11.000 17 W ecl,N 1.000 1.000 W ec2,N fc [psi] 3000 4) seismic 1.000 1.000 nonductile 1.000 W ed,N 1.000 $ Vcpg [Ib] 2868 1 N/A W cp,N 1.000 Vua [Ib] 20 Status OK N/A OK OK Nb [lb] 2634 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 www.hilti.us 1M11`TI Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sitts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 5 Boeing 9-08 Lobby 10/9/2017 4.3 Concrete edge failure in direction y+ A Vcbg — \Avco) W ec,V W ed,V W c,V W h,V W parallel,V Vb Vcbg 2 Vua Avc see ACI 318-14, Section 17.5.2.1, Fig. R 17.5.2.1(b) Avco = 4.5 cat 1 1+ 2e <_ 1.0 3c51 =0.7+0.3(15oat)s1.0 = 1.5cat > 1.0 ha 0.2 �� �� =. (7 (a ) Yua) X. a Vrc caS W ec,V w ed,V w h.V Vb Variables cal [In.] 8.667 ca2 [in.] 11.000 a eav [in.] 0.000 da [in.] ACI 318-14 Eq. (17.5.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.5.2.1c) ACI 318-14 Eq. (17.5.2.5) ACI 318-14 Eq. (17.5.2.6b) ACI 318-14 Eq. (17.5.2.8) ACI 318-14 Eq. (17.5.2.2a) 2.000 Calculations Avc [in 2] 96.00 Results Vcbg [Ib] 4089 1.000 0.375 w c,V ha [In.] 1.000 4.000 fa [psi] W parallel,V 3000 1.000 Avco [in.2] W ec,V W ed,V W h,V Vb [Ib] 338.00 1.000 0.954 1.803 8372 concrete 0.700 4> seismic 4> nonductiie Vcbg [Ib] Vua [Ib] 1.000 1.000 2862 20 5 Combined tension and shear loads [3N 13V 5 Utilization (3N,V [%a] Status 0.084 0.007 5/3 2 OK t+NV = I+N +13./ <= 1 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 11 7 www.hilti.us Millar I Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 6 Boeing 9-08 Lobby 10/9/2017 6 Warnings • The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load re -distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies when supplementary reinforcement is used. The cD factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 1723.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding ata load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non -yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that. include E, with E increased by wo. • Hilti post -installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 12 G 0 0 G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G www.hilti.us Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 7 Boeing 9-08 Lobby 10/9/2017 7 Installation data Anchor plate, steel: - Profile: Rectangular HSS (AISC); 0.875 x 0.875 x 0.062 in. Hole diameter in the fixture: df = 0.438 in. Plate thickness (input): 0.162 in. Recommended plate thickness: not calculated Drilling method: Hammer drilled Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Installation torque: 300.000 in.lb Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.625 in.. Minimum thickness of the base material: 4.000 in. 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool (Hilti Safeset System) • Torque wrench • Hammer Coordinates Anchor in. Anchor x y 1 1.000 -1.000 2 -1.000 1.000 c.x 13.000 11.000 C+x 11.000 13.000 c -y 11.000 13.000 c+y 13.000 11.000 x Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 13 O O O O o. 2 O O 0- N' O N O o. 0 1 • O O O N 1.000 2.000 1.000 • Coordinates Anchor in. Anchor x y 1 1.000 -1.000 2 -1.000 1.000 c.x 13.000 11.000 C+x 11.000 13.000 c -y 11.000 13.000 c+y 13.000 11.000 x Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 13 www.hilti.us Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 8 Boeing 9-08 Lobby 10/9/2017 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on -the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the datato be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suutability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilt] is a registered Trademark of Hilti AG, Schaan 14 www.hilti.us 1411`,' Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 1 Boeing 9-08 Lobby 10/9/2017 Specifier's comments: Load Case "B" 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Effective embedment depth: hef,act = 2.000 in., hnom = 2.313 in. Material: Carbon Steel Evaluation Service Report: ESR -1917 Issued I Valid: 6/1/2016 15/1/2017 Proof: Design method ACI 318-14 / Mech. Stand-off installation: Anchor plate: Profile: Rectangular HSS (AISC); (L x W x T) = 0.875 in. x 0.875 in. x 0.062 in. Base material: cracked concrete, 3000, fo' = 3000 psi; h = 4.000 in. Installation: Reinforcement: SAFE:ET eb = 0.000 in. (no stand-off); t = 0.162 in. Ix x lY x t = 4.000 in. x 4.000 in. x 0.162 in.; (Recommended plate thickness: not calculated Seismic loads (cat. C, D, E, or F) Geometry [in.] & Loading [Ib, in.Ib] hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Z 0 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 15 www.hilti.us '-'H-UTI Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sitts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 2 Boeing 9-08 Lobby 10/9/2017 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 65 10 7 7 2 65 10 7 7 max. concrete compressive strain: 0.04 [%o] max. concrete compressive stress: 190 [psi] resulting tension force in (x/y)=(0.000/0.000): 1129 [Ib] resulting compression force in (x/y)=(1.495/1.495):129 [Ib] 3 Tension load Steel Strength* Pullout Strength* Concrete Breakout Strength** Load Nua [Ib] 65 65 129 Capacity Nn [Ib] Utilization YN = Nua/+ Nn * anchor having the highest loading **anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value Nsa Nua Variables f 1 Ase,N 0.05 Calculations Nsa [Ib] 6500 Results Nsa [Ib] 6500 refer to ICC -ES ESR -1917 ACI 318-14 Table 17.3.1.1 luta [psi] 125000 4) steel 0.750 3.2 Pullout Strength Npn.f = Np,2500 ? a 2500 Npn,f z Nua ACI 318-14 Table 17.3.1.1 nonductile 1.000 refer to ICC -ES ESR -1917 Variables fc [psi] a Np,2500 [Ib] 3000 1.000 2270 Calculations 2500 1.095 Results Non,f [Ib] 4) concrete 4t seismic 2487 0.650 0.750 4875 1212 1997 4) N. [Ib] Nua [Ib] 4875 65 ynonductile 1.000 2 6 7 Non,f, [lb] Nua [Ib] 1212 65 Status OK OK OK Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 16 www.hilti.us 1.11`TI Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 3 Boeing 9-08 Lobby 10/9/2017 3.3 Concrete Breakout Strength ANc Ncbg = (ANco) V ec,N V ed,N V c,N V cp,N Nb Ncbg i Nua ANC see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANcO W ec,N V ed,N V cp,N Nb = 91\20 1 1+2e.N <_1.0 3 hef =0.7+0.3(C,min11.0 `1.5hef JJ = MAX(c"" 1.5hef c 1.0 Cac cac = kc %. a VTc hef5 Variables het [in.] 2.000 cac [in.] 4.375 Calculations ANc [in.2] 56.00 Results Ncbg [lb] 4097 ec1,N [in.] ec2,N [in.] ACI 318-14 Eq. (17.4.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.4.2.1c) ACI 318-14 Eq. (17.4.2.4) ACI 318-14 Eq. (17.4.2.5b) ACI 318-14 Eq. (17.4.2.7b) ACI 318-14 Eq. (17.4.2.2a) ca,min [in.] V c,N 0.000 kc 0.000 17 ANco [in.2] 36.00 4) concrete 0.650 X 1.000 11.000 V ecl,N fc [psi] 3000 1.000 4) seismic V ec2,N 1.000 0.750 1.000 V ed,N nonductile 1.000 1.000 Nchg [Ib] 1997 V cp,N 1.000 Nb [Ib] Nua [Ib] 129 2634 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 17 e 8 B a a B a 8 a e e a a e a a a www.hilti.us Profis Anchor 2.7.3 Company: Specifier: Address: Phone 1 Fax: E -Mail: Silts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 4 Boeing 9-08 Lobby 10/9/2017 4 Shear load Load Vua [Ib] Capacity $ V„ [Ib] Utilization ]3v = Vua/41 V, Status Steel Strength* 10 1466 1 OK Steel failure (with lever arm)* N/A N/A N/A N/A Pryout Strength** 20 2868 1 OK Concrete edge failure in direction x+** 20 2862 1 OK * anchor having the highest loading **anchor group (relevant anchors) 4.1 Steel Strength Vsa,eq = ESR value Vsteel > Vua Variables Ase,V [in.2] 0.05 Calculations Vsa,aq [Ib] 2255 Results Vsa,eq [Ib] 2255 refer to ICC -ES ESR -1917 ACI 318-14 Table 17.3.1.1 luta [psi] 125000 4.2 Pryout Strength $ steel 4) nonductile 4) Vsa [Ib] Vua [Ib] 0.650 1.000 1466 10 fr ANc Von — "op ��ANco) W ec,N W ed,N W c,N W cp,N Nb]1 41 Vcpg z Vua ACI 318-14 Table 17.3.1.1 AN, see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b) ANco = 9 hef ACI 318-14 Eq. (17.4.2.1c) 1 W acN = 1 + 2 eN5 1.0 ACI 318-14 Eq. (17.4.2.4) 3 hef� W ed,N = 0.7 + 0,3 (ca,min) 5 1.0 1.5het ACI 318-14 Eq. (17.4.2.5b) W cp,N= MAXrCa_min 1.5hef) c 1.0 ACI 318-14 Eq. (17.4.2.7b) `` Cac Cac Nb = kc ?. a ? hei5 ACI 318-14 Eq. (17.4.2.2a) ACI 318-14 Eq. (17.5.3.1b) Variables kcp hat [in.] ect,N [in.] ec.2,N [in.] camin [in.] 1 2.000 0.000 0.000 11.000 W c,N Cac [in.] kc A. a fc [psi] 1.000 4.375 17 1.000 3000 Calculations ANc [in.2] ANco [in.2] lit eat ,N W ec2,N y1 ed,N W cp,N Nb [lb] 56.00 36.00 1.000 1.000 1.000 1.000 2634 Results Vcpg [Ib] 4) concrete 41 seismic 4) nonductile 4) Vcp9 [Ib] Vua [lb] 4097 0.700 1.000 1.000 2868 20 Input data and results must be checked for agreement with the existing conditions and for plausibility) PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 18 www.hilti.us 1■■11`.TI Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 5 Boeing 9-08 Lobby 10/9/2017 4.3 Concrete edge failure in direction x+ Vcbg = (AVcO/ W ec,V V ed,V V c,V W h,V W parallel,V Vb Vcbg 2 Vua Av. see ACI 318-14, Section 17.5.2.1, Fig. R 17.5.2.1(b) Avco W ec,V W ed,V W h,V = 4.5 oaf 1 ( - 2ev1<_1.0 \1+3cat/ =0.7+0.3(1.5cat)51.0 1.5cat > 1.0 ha 02 Vb = (7 (21) '\/,Tia) ),,a•VTCCi5 Variables Cal [in.] 8.667 le [in.] ca2 [in.] ecv [in.] ACI 318-14 Eq. (17.5.2.1b) ACI 318-14 Table 17.3.1.1 ACI 318-14 Eq. (17.5.2.1c) ACI 318-14 Eq. (17.5.2.5) ACI 318-14 Eq. (17.5.2.6b) ACI 318-14 Eq. (17.5.2.8) ACI 318-14 Eq. (17.5.2.2a) 11.000 Iva 0.000 da [in.] 2.000 Calculations Avc [in.2] 96.00 Results Vcbg [Ib] 4089 1.000 Avco [in.2] 0.375 338.00 4) concrete 0.700 W ec,V 1.000 W c,V 1.000 ha [in.] fc [psi] 3000 4.000 W parallel,V. 1.000 W ed.v W h,V Vb [Ib] 0.954 1.803 8372 4) seismic 4) nonductile 4, Vcbg [Ib] Vua [Ib] 1.000 1.000 2862 20 5 Combined tension and shear loads 13N 13v Utilization (3N,v [%] Status 0.065 0.007 5/3 2 OK RNV=J3 + <= 1 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 19 www.hilti.us I -HI -T1 Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 6 Boeing 9-08 Lobby 10/9/2017 6 Warnings • The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load re -distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies when supplementary reinforcement is used. The ct factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non -yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by coo. • Hilti post -installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPI!). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 20 a B a a a a a D a a e B a B a B a a www.hilti.us 1-111-T1 Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sifts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 7 Boeing 9-08 Lobby 10/9/2017 7 Installation data Anchor plate, steel: - Profile: Rectangular HSS (AISC); 0.875 x 0.875 x 0.062 in. Hole diameter in the fixture: df = 0.438 in. Plate thickness (input): 0.162 in. Recommended plate thickness: not calculated Drilling method: Hammer drilled Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Installation torque: 300.000 in.lb Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.625 in. Minimum thickness of the base material: 4.000 in. 7.1 Recommended accessories Drilling Cleaning • Suitable Rotary Hammer • Manual blow-out pump • Properly sized drill bit ♦y Setting • Torque controlled cordless impact tool (Hilti Safeset System) • Torque wrench • Hammer _ • __ _ _ Co O 0 0 0 2 O O O N O N O O 1 • O' O O o N 1.000 2.000 , 1.000 Coordinates Anchor in. Anchor x 1 1.000 -1.000 13.000 2 -1.000 1.000 11.000 c+x 11.000 13.000 c.y 11.000 13.000 c+y 13.000 11.000 x Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 21 www.hilti.us Profis Anchor 2.7.3 Company: Specifier: Address: Phone I Fax: E -Mail: Sitts & Hill Engineers BRL Page: Project: Sub -Project I Pos. No.: Date: 8 Boeing 9-08 Lobby 10/9/2017 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only, as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 22 0 SITTS & HILL ENGINEERS, INC. 0 Professional Engineers and Planners 4815 Center Street, Tacoma, WA 98409 www.sitts-hill-engineers.com (253) 474-9449 November 8, 2017 THE BOEING COMPANY P.O. Box 3707 M/C 46-88 Seattle, WA 98124-2207 TO: Mr. John S Murdoch SUBJECT: PERMIT REVIEW COMMENT REPONSES Building 9-08 Lobby Renovation Permit Application Number D17-0279 Dear Mr. Murdoch: BRENT K. LESLIE, P.E. KATHY A. HARGRAVE, P.E. LARRY G. LINDELL, P.E. MICHAEL A. McEVILLY, P.L.S. The purpose of this letter is to respond to the permit review comments for the above project that are on the attached letter from the City of Tukwila dated October 26, 2017 The review comment along with response is listed below. The drawings that are affected by these comments have been revised and an entire set of drawings is attached with this letter. The revisions on the drawings are clouded and noted with a revision symbol. Building Review Notes: 1.) City of Tukwila Comment: The plan calls for a new raised floor system. However, it is not clear at to where the raised floor starts by a step or ramp. Please provide clarification and include manufactures installation details for the raised floor system. Show an accessible ramp detail if applicable. Sitts & Hill Engineers Response: The existing floor system in the proposed work area is currently a raised floor system that will be replaced and reconfigured to accommodate the new use of the spaces. The rooms are now delineated and notes on drawing 1/1A450, they are Vestibule -100, Conference Room -100A and Storage Room -100B. The finish floor level of the new raised floor system will be flush with the same level of the surrounding existing building floor area therefore no ramps or steps will be required to access this new area. The Scope of Work on drawing sheet Al has been revised along with drawing 1/1A450, Finish Schedule 4/A350 and Material Finish Schedule 5/A350 to help make this clear. Manufacturer product data and installation details of the raised floor system have been attached to this letter. The specification for the raised floor system is described on drawing sheet A2. 2.) City of Tukwila Comment: Indicate ceiling height to the raised floor system. Also provide dimensions for height of raised floor system on the detail A sheet A501. br Oziq Civil, Structural and Surveying RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER 0 0 November 6, 2017 Page 2 of 2 Sifts & Hill Engineers Response: The height of the ceiling is 9'-0" above finish floor level. This is now noted on drawing 1/1A451 and the Room Finish Schedule 4/A350. Also, dimensions for the height of the raised floor system have been added to Section A/A501. A "Field Verify" note has been included with this dimension, as the intention is for the new raised floor system to be at the same elevation as the existing floor system. 3.) Engineer's calculations indicate bolting the floor system to the concrete floor. Provide the required special inspections for the floor systems bolting/anchoring to the floor. Sitts & Hill Engineers Response: Please see the attached completed Special Inspection package for this project. 4.) Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Forms for Commercial Buildings available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions — Compliance Forms"). Sitts & Hill Engineers Response: See attached WSEC Lighting Summary. Please feel free to contact our office with any additional questions or comment regarding this project. Sincerely, David C. Boileau, A.I.A. Project Architect Reviewed by Brent K. Leslie, P.E., S.E. Sr. Vice President Attachments: Permit Drawings (Revised) DCD Permit Special Inspection Form Raised Floor System Product Data & Details WSEC Lighting Summary October 26, 2017 0 City of Tukwila Department of Community Development JOHN S MURDOCH PO BOX 3707 MC 46-88 SEATTLE, WA 98124 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0279 BOEING #+9-08 - 9725 E MARGINAL WAY S Dear JOHN S MURDOCH, a Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. The plan calls for a new raised floor system. However, it is not clear as to where the raised floor starts by a step or ramp. Please provide clarification and include manufacturers installation details for the raised floor system. Show an accessible ramp detail if applicable. 2. Indicate ceiling height to the raised floor system. Also provide dimensions for the height of the raised floor system on the detail A sheet A501. 3. Engineer's calculations indicate bolting the floor system to the concrete floor. Provide the required special inspections for the floor systems bolting/anchoring to the floor. 4. Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Forms for Commercial Buildings available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, %zd Bill Rambo Permit Technician File No. D17-0279 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PRMIT COORD COPY ° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0279 DATE: 11/09/17 PROJECT NAME: BOEING #9-08 SITE ADDRESS: 9725 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 16 Buildin Divisioi g Public Works ❑ Fire Prevention Structural Planning Division n ❑ Permit Coordinator [_IJE PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/14/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/12/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: R.EVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 CPEMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0279 DATE: 10/13/17 PROJECT NAME: BOEING #9-08 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Pi -J \0\ii Building Division i4g ‘0 1 Public Works 411/44 Aux 14)4,47 LA.) &or Fire Prevention Planning Division Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/17/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required Denied (ie: Zoning Issues) Approved with Conditions (corrections entered in Reviews) DUE DATE: 11/14/17 n Notation: REVIEWER'S INITIALS: DATE: !Permit Center Use Only . CORRECTION LETTER MAILED: 10 f 7 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Det,elopntent 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 . Web site: hip://uu'lr.c•i.trrktrila.Iva.us REVISION SUBMITTAL Revision submittals must he submitted in person at the Permit Center. Revisions ►vill not he accepted through the null/, fax, etc. Date: 11/9/2017 Plan Check/Permit Number: D17 0279 ❑ Response to Incomplete Letter # E Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CITY OE TUKWILA SOV 19 2011 PERMIT CENTER Project Name: Boeing #9-08 Project Address: 9725 E Marginal Way S Contact Person: Phone Number: Summary of Revision: The purpose of this resubmittal is to respond to the permit review comments.for the above project that are on the attached letter from the City of Tukwila dated October 26, 2017 The review comment along with response is listed in the attached letter. The drawings that are affected by these comments have been revised and an entire set of drawings is attached with this letter. The revisions on the drawingsare clouded and noted with a revision symbol. Sheet Number(s): Al, 1 A450, 1 /A451, A350, A501, 1E12 "Cloud" or highlight all areas of revision including date of re'isiorf Received at the City of Tukwila Permit Center by: 51— Entered in 'T•RAKiT on _c,.. \;ipplicalions\limns -upplieations on liar\revision submittal Created: 8-13-2004 R rvicry l' BOEING COMPANY, THE Home Espaiiol Contact Safety & Health 0 Washington State Department of Labor & Industries 0 Search L&I A -Z Index Help Page 1 of 9 My f,&T Claims & Insurance Workplace Rights Trades & Licensing BOEING COMPANY, THE Owner or tradesperson LOHR, MICHAEL Principals LOHR, MICHAEL, SECRETARY MCNERNEY, W (JAMES), PRESIDENT (End: 01/13/2017) WOLTER, CHRISTOPHER, TREASURER (End: 01/16/2015) READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) WA UBI No 178 005 030 100 N RIVERSIDE M/C 5003-4027 CHICAGO, IL 60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BOEINC*294ML Effective expiration 07/13/1971— 01/18/2019 Help us improve https://secure.lni.wa.gov/verify/Detaill.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 11/27/2017 BOEING COMPANY, THE Bond FEDERAL INS CO Bond account no. 81312466 $12,000.00 Received by L&I Effective date 01/14/2002 01/01/2002 Expiration date Until Canceled Insurance ............................. Ace American Insurance Company Policy no. HDOG27870442 $10,000,000.00 Received by L&I Effective date 10/06/2017 10/01/2017 Expiration date 10/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&l tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. License Violations .................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 700,216-00 Doing business as BOEING COMPANY THE Estimated workers reported N/A L&I account contact (360)902-4817 Track this contractor tom; Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/31/2017 Inspection no. 317945013 Location 3003 W Casino Rd Everett, WA 98203 No violations Page 2 of 9 Help us improve https://secureini.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 11/27/2017 VICI\ITY yAP PROJECT SITE FROM DOWNTOWN SEATTLE 0 14-01 900 rnm to 99 EXIT 158 0E NO ACCESS RDN Q EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT DEVELOPN E 599 TUKWILA \TAL C E \TE FROM KENT & AUBURN NO SCALE 900 SYM REVISION BY APPROVED DATE SYM BOEING AIRCRAF AND MISSILES GROUP BUILDING 9-08 LOBBY RENOVATION BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA NAP 3UILDI \G ADDRESS: 9725 EAST NAKI\AL WAY SOUTH TU <WILA, WASHI\GTO\ NO SCALE 9-08 3UILDI\G LOCATION REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 A PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 GE\ERAL \OTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BLDG. 9-51.2 COL M/2, AFTER COMPLETION OF THIS CONSTRUCTION. CCDE SUN IVAY BUILDING CODE OCCUPANCY GROUP CONSTRUCTION TYPE LOCATION ON PROPERTY FLOOR AREA (ACTUAL): BUIDLING FOOTPRINT BUILDING GROSS 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR PENTHOUSE BUIDLING HEIGHT STORIES OCCUPANT LOAD: OFFICE © 1 TO 100SF MECH/STORAGE © 1 TO 300SF OTHER © 1 TO 100SF HANDICAPPED REQUIREMENTS FIRE PROTECTIONS SEPARATION EXTERIOR WALL (NON—BEARING) INTERIOR WALLS (NON—BEARING) INTERIOR WALLS (BEARING) STRUCTURAL FRAME FLOORS STAIR ENCLOSURES SHAFT ENCLOSURES ELEVATOR SHAFT CORRIDORS ROOF ROOFING CONSTRUCTION SEISMIC ZONE DESIGN LOADS: ROOF — SNOW LIVE FLOOR OFFICE (LIVE) DEAD MECH & STORAGE STAIRS & CORRIDOR WIND 2015 INTERNATIONAL BUILDING CODE B BUSINESS (GROUP B, PROFESSIONAL SERVICES — ENGINEERS) TYPE II—A (FORMERLY II—FR) MINIMUM 60 FT. ALL SIDES 50,207 SF (37,500SF X 2=75,000SF ALLOWABLE W/SPRINK INCR.) 253,832 SF 50,012 SF 50,207 SF 50,207 SF 50,207 SF 50,207 SF 2,992 SF 84'-1" ROOF PARAPET, 95'-3" PENTHOUSE PARAPET, 85' ALLOW 5 (5 ALLOW PER 97UBC, 5 +1=6 SPRINKLER ADD ALLOWABLE) 1ST FLR © 340 2ND, 3RD, 4TH, 5TH © 419 EACH BUILDING TOTAL = 2016 BARRIER FREE FULLY AUTOMATIC THROUGH—OUT F/S CLASS 1 HOUR UNPROTECTED (UBC & IBC) 1 HR 97UBC & 2003 IBC 2 HR 97 UBC 1 HR 2003 IBC 2 HR 97 UBC, 1 HR 2003 IBC 2 HR 97 UBC, 1 HR 2003 IBC 2 HR 97 UBC & 2003 IBC 2 HR 97 UBC & 2003 IBC 2 HR 97 UBC & 2003 IBC 1 HR 97 UBC & 2003 IBC 1 HR 97 UBC & 2003 IBC FIRE RETARDANT: CLASS A (FM CLASS 1) CATEGORY 'D' 25 PSF 20 PSF 100 PSF 20 PSF (PARTITION) 125 PSF 100 PSF 110 MPH 1 ARCHITECT'S INTENT: FOR 2015 IBC WORK DESIGN WILL MAINTAIN EXISTING LIKE KIND MATERIALS AND ASSEMBLIES PER 97 UBC REQUIREMENTS. gOg OrM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE REVISIONS ''^nele to the scop® —,nrovai of NOT;., ,,� .. Vii.t 1, will and may include ads :� ; , an submittal tees. .... _., 1.......... _ . SEPARATE E PEST ' REQUIRED E: G'Mecnanicc. Q ' Iectrica! L�ilumbin GaoPipic City of BUILDING I` FILE COPY craft No. Oh - 1q Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinanc3. Raceipt of approved Field Copy and con itions is acknflwlodgod: By: ///v1,'� Date: // -2- I jt City of Tukwila BUILDING DIVISION NAWI\G INDEX DRAWING NUMBER SHEET NUMBER TITLE REVISION N DATE 9-08—Al Al COVER SHEET A 11.09.17 9-08—A2 A2 GENERAL DESIGN NOTES — 11.09.17 9-08-1A01 1A01 EXITING PLAN C 11.09.17 9-08-1Al2 1Al2 FLOOR PLAN M 11.09.17 9-08-1A282 1A282 REFLECTED CEILING PLAN A 11.09.17 9-08-1 A45OR 1A45OR ENLARGED FLOOR PLAN — REMOVAL -- 11.09.17 9-08-1A450 1A450 ENLARGED FLOOR PLAN A 11.09.17 9-08-1A451 R 1A451R ENLARGED REFLECTED CEILING PLAN — REMOVAL 11.09.17 9-08-1A451 1A451 ENLARGED REFLECTED CEILING PLAN A 11.09.17 9-08—A350 A350 SCHEDULES A 11.09.17 9-08—A370 A370 INTERIOR ELEVATIONS -- 11.09.17 9-08—A500 A500 MISC. SECTIONS AND DETAILS -- 11.09.17 9-08—A501 A501 MISC. SECTIONS AND DETAILS A 11.09.17 sty'` ;i'ti A 9-08-1E12 1E12 LIGHTING PLAN G 11.09.17 A SCOPE OF WORK CONVERT APPROXIMATELY 1,200 SF OF EXISTING SHIELDED LABYRINTH SPACE INTO ENTRY VESTIBULE (200 SF), CONFERENCE ROOM (697 SF) AND STORAGE ROOM (118 SF). WALLS TO BE ADDED AND BRACED TO STRUCTURE ABOVE TO CREATE THESE SEPARATE SPACES. A NEW SUSPENDED ACOUSTICAL CEILING, WALL FINISHES, AND CASEWORK WILL BE ADDED. THE EXISTING FLOOR SYSTEM IS AN RAISED FLOOR SYSTEM THAT WILL BE REPLACED AND RECONFIGURED WITH A NEW RAISED FLOOR SYSTEM WITH- THE- FINISH FLOOR LEVEL BEING AT THE SAME LEVEL OF THE EXISTING FLOOR LEVEL. THERE WILL BE NO CHANGES TO THE EXISTING BUILDING CONSTRUCTION TYPE, OCCUPANCY GROUP OR EXITING SYSTEM. A REVIEWED FOR CODE COMPLIANCE APPROVED D�7- oz�q NOV 21. 2017 ?9,- CORRECTION City of Tukwila LTR# ` BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 COVER SHEET RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474.9449 I FAX: (253) 474.9449 http://www.sitts-hIll-englneers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED TITLE ARCHITECTURAL MASTER LOBBY RENOVATION BUILDING 9-08 DEV .CENTER, WA SHEET Al JOB NO. 33658 COMP NO. DWG NO. 9-08—Al oo o 0 CD LO 0 0 to GENERAL DESIGN NOTES (GDN) BUILDING CODE AND SPECIFICATIONS: ALL CODE REFERENCES HEREAFTER SHALL CORRESPOND TO THE FOLLOWING EDITIONS WITH STATE OF WASHINGTON AND CITY OF TUKWILA AMENDMENTS TO BE USED, U.N.O.: EDITION 2015 ICC/ANSI A117.1-03 2015 2015 2015 2015 2011 2015 ASCE 31-03 ASCE/SEI 41-06 ASCE/SEI 7-10 MATERIAL STEEL WELDING COLD FORMED STEEL CODE INTERNATIONAL BUILDING CODE ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES INTERNATIONAL MECHANICAL CODE INTERNATIONAL FIRE CODE INTERNATIONAL PLUMBING CODE INTERNATIONAL ENERGY CONSERVATION CODE NATIONAL ELECTRICAL CODE INTERNATIONAL FUEL GAS CODE SEISMIC EVALUATION OF EXISTING BUILDINGS SEISMIC REHABILITATION OF EXISTING BUILDINGS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES CODE EDITION 14TH EDITION OF (AISC) STEEL CONSTRUCTION MANUAL. STRUCTURAL WELDING CODE — STEEL, (AWS) D1.1-15. 2012 (AISI) NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD—FORMED STEEL STRUCTURAL MEMBERS 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), WITH CITY OF TUKWILA AMENDMENTS SHALL BE USED AND SUPPLEMENTED WITH ASCE 7-10. (AISC) MANUAL OF STEEL CONSTRUCTION — 14TH EDITION. (AWS) STRUCTURAL WELDING CODE / STEEL — AWS D1.1-11. CONCRETE (ACI 318)-11. REINFORCING 2004 ACI DETAILING MANUAL (ACI SP -66). AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM) STANDARDS. LOADS: LIVE LOAD = 100 PSF WIND LOAD (INTERIOR STRUCTURE) = 5 PSF SEISMIC COEFFICIENTS FOR LATITUDE. 47.5163 DEGREES, LONGITUDE —122.2986 DEGREES AND SITE CLASS "D", BUILDING DESIGN CATEGORY "D": Ss = 1.515, S1 = 0.573 Sds = 1.010, Sd1 = 0.573 GENERAL: THE CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT ARE NOT LIMITED TO BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE 2015 IBC (WITH STATE OF WASHINGTON AMENDMENTS) CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS OR MATERIALS, SUCH STANDARDS SHALL BE THE IATEST EDITION AND/OR ADDENDA, U.N.O. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS CHOSEN, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES AND SHALL COORDINATE ALL DETAILS. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL ARCHITECTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE OWNER. TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY, U.N.O. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL ARCHITECTURAL NOTES AND/OR SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A REGISTERED ENGINEER RECOGNIZED BY THE BUILDING CODE JURISDICTION OF THIS PROJECT. PLAN DIMENSIONS SHOWN ARE TAKEN TO FACE OF STUD OR FACE OF CONCRETE U.N.O. HEIGHTS SHOWN OR NOTED AFF (ABOVE FINISH FLOOR) ARE TO BE MEASURED FROM TOP OF FINISH FLOORING MATERIAL. DO NOT SCALE DRAWINGS. IF UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK, CONSULT OWNER FOR DIRECTION BEFORE PROCEEDING. IF DRAWINGS MEASURE LESS THAN 24" x 36", PRINTS ARE REDUCED FROM ORIGINALS. DETAILS SHOWN ON CONSTRUCTION DOCUMENTS SHALL BE INCORPORATED INTO THE PROJECT AT ALL APPROPRIATE LOCATIONS WHETHER SPECIFICALLY REFERENCED AT EACH LOCATION OR NOT. ADJUNCT CONSTRUCTION — THE EMBEDMENT OR PASSAGE OF PIPING, ELECTRICAL CONDUIT, DUCTWORK AND OTHER MATERIALS THAT WOULD REDUCE THE STRENGTH OF ROOFS AND/OR FRAMING IS NOT PERMITTED UNLESS THE WORK IS DONE IN ACCORDANCE WITH THE STANDARD DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS. THIS WORK MUST BE REVIEWED BY THE OWNER PRIOR TO CLOSING IN AND /OR CASTING. SEE STANDARD DETAILS AND PROJECT MANUAL FOR THE RELATIONSHIP OF UNDERGROUND CONDUIT AND PIPING TO FOUNDATIONS, FOR OPENINGS, FOR PIPING IN WALLS AND OTHER SPECIAL CONDITIONS REQUIRED FOR THIS PROJECT. WHERE PLAN NOTES CALL FOR THE CONTRACTOR TO INSTALL SPECIAL ITEMS, IT IS TO BE EXPLICITLY UNDERSTOOD THAT THE CONTRACTOR IS TO ALSO PROVIDE THAT ITEM AND ALL ACCESSORY EQUIPMENT REQUIRED TO INSTALL THAT ITEM(S). IF ITEM IS TO BE PROVIDED BY OWNER, IT WILL BE SO INDICATED. CONTRACTOR SHALL REPAIR ALL CONSTRUCTION DAMAGE NOT LIMITED TO GRASS, PAVED AREAS AND OTHER ITEMS TO PRE—CONSTRUCTION CONDITION FROM DAMAGE DURING CONSTRUCTION. PROVIDE PHOTOGRAPHS PRIOR TO STARTING WORK AND DELIVER TO OWNER. CHANGES TO THE APPROVED DRAWINGS AND PROJECT MANUAL SHALL BE MADE BY AN ADDENDA OR CHANGE ORDER SIGNED BY THE OWNER. THE ELECTRICAL, PLUMBING, AND MECHANICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE DRAWINGS TO DETERMINE THE LOCATION OF PROPOSED EQUIPMENT, OUTLETS, OR OTHER ITEMS. SEE SCHEDULES, DETAILS, AND CONSTRUCTION DOCUMENTS FOR MOUNTING HEIGHTS OF ACCESSORIES. MAINTAIN FIRE RESISTANCE RATING OF RATED ASSEMBLIES BEHIND RECESSED WALL ACCESSORIES, INCLUDING FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, MISCELLANEOUS ACCESSORIES, ELECTRICAL JUNCTION BOXES, AND OTHER ITEMS WHERE OCCURRING. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE APPLICABLE CODES. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NONCOMPLYING CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISH WORK WILL NOT COMPLY WITH THE APPLICABLE CODES, A CHANGE ORDER OR SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILING AND SPECIFYING THE REQUIRED WORK, SHALL BE SUBMITTED TO AND APPROVED BY THE AGENCY HAVING JURISDICTION. MAINTAIN FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION IN ACCORDANCE WITH THE 2015 EDITION OF THE INTERNATIONAL FIRE CODE. CONCRETE: MINIMUM 28—DAY STRENGTH, f'c SHALL BE 4,000 PSI. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AT TRENCHES, FLOOR DUCTS, TURNDOWNS, ETC. MAXIMUM SLUMP IS 4 1/2" FOR CONCRETE WITHOUT PLASTICIZER. IF PLASTICIZER IS USED, A HIGHER FINAL SLUMP MAY BE ALLOWED UPON STRUCTURAL ENGINEER'S APPROVAL. MAXIMUM WATER/CEMENT RATIO (W/C) SHALL BE 0.45. COURSE AGGREGATE MATERIAL SHALL BE 3/4" MINUS, WELL GRADED. UNLESS APPROVED OTHERWISE IN WRITING BY THE STRUCTURAL ENGINEER, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY CONTROL JOINTS AS SHOWN ON THE SLAB PLAN. PROVIDE AIR ENTRAINMENT (5% +/— 1%) IN CONCRETE EXPOSED TO FREEZE—THAW ACTION. FLY ASH SHALL BE LIMITED TO 15% OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK. REINFORCING: USE ASTM A615, GRADE 60 (Fy = 60 KSI) FOR ALL DEFORMED REINFORCING, U.N.O. WHERE SHOWN ON DRAWINGS, ALL GRADE 60 REINFORCING TO BE WELDED SHALL BE ASTM A706. NO TACK WELDING OF REINFORCING BARS IS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. CLEAR CONCRETE COVERAGES SHALL BE AS FOLLOWS: CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH EXPOSED TO EARTH OR WEATHER #6 OR LARGER 2" 5 AND SMALLER- 1 •1/2" FLAT SLAB- 3/4" 3" ALL OTHER PER A.C.I. 318. LAP SPLICES IN CONCRETE: LAP SPLICES, U.N.O., SHALL BE CLASS "B" TENSION LAP SPLICES PER ACI 318. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. ALL REINFORCING SHALL BE CHAIRED TO ENSURE PROPER CLEARANCES. SUPPORT OF FOUNDATION REINFORCING MUST PROVIDE ISOLATION FROM MOISTURE/ CORROSION. ALL SPLICE LOCATIONS SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER ACI SP -66. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION WITH STANDARD 90—DEGREE HOOKS, U.N.O. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. CONCRETE/SEALING COMPOUND: CONCRETE CURING AND SEALING COMPOUNDS SHALL BE ASHFORD FORMULA BY CURECRETE DISTRIBUTION. APPLY PER MANUFACTURER'S RECOMMENDATIONS. DRYPACK: DRYPACK SHALL BE 5,000—PSI NON—SHRINK GROUT, FIVE STAR OR ACCEPTED SUBSTITUTION. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO STRUCTURE INSTALLATION. CONCRETE SLAB JOINT PROTECTION: JOINT PROTECTION SHALL BE PER SPECIFICATIONS, PLANS AND DETAILS. RECOMMENDATIONS. BONDING AGENT AND CORROSION PROTECTION: A BONDING AGENT SHALL BE APPLIED TO EXISTING CONCRETE SURFACES WHERE NEW CONCRETE IS TO BE PLACED. USE "SIKA" ARMATEC 100 EPOCHEM BONDING AGENT AND REINFORCEMENT PROTECTION, OR ACCEPTED SUBSTITUTION. PREPARE THE EXISTING CONCRETE SURFACES AND APPLY THE BONDING AGENT PER THE MANUFACTURER'S INSTRUCTIONS. CONCRETE REPAIR: AT EXISTING SLAB LOCATIONS WHERE THE SLAB SHOWS SIGNS OF SPALLING, CHIPPING OR DAMAGE, PROVIDE THE FOLLOWING REPAIR: 1. THE DAMAGED AREA SHALL BE CHIPPED AWAY OR SAWCUT AS REQUIRED TO PROVIDE A VERTICAL FACE ON ALL EDGES WITH A MINIMUM DEPTH OF 1/8" THROUGHOUT. 2. CLEAN THE DAMAGED AREA AND PROVIDE A PRIMER/SCRUB COAT OF SIKATOP 122 PLUS OR ACCEPTED SUBSTITUTION. 3. A REPAIR COAT OF SIKATOP 122 PLUS OR ACCEPTED SUBSTITUTION SHALL THEN BE ADDED TO FILL IN THE DAMAGED AREAS OF CONCRETE. 4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS SHALL BE FLAGGED UPON CONTRACTOR'S REVIEW. VERIFY ALL DIMENSIONS WITH OWNER. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DOCUMENTS SHALL BE CLOUDED BY MANUFACTURER OR FABRICATOR. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. THE ENGINEER HAS THE RIGHT TO APPROVE OR DISAPPROVE ANY CHANGES TO CONTRACT DOCUMENTS AT ANY TIME BEFORE OR AFTER SHOP DRAWING REVIEW. THE SHOP DRAWINGS DO NOT REPLACE THE CONTRACT DOCUMENTS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER SHALL NOT BE CONSIDERED CHANGES TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE ITEMS ARE CONSTRUCTED TO CONTRACT DOCUMENTS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. SPECIAL INSPECTION — STRUCTURAL ONLY: SPECIAL INSPECTION IS TO BE PROVIDED FOR THE ITEMS LISTED BELOW IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE BUILDING SAFETY DEPARTMENT. "SPECIAL STRUCTURAL INSPECTION" SHALL NOT RELIEVE THE OWNER OR THEIR AGENT FROM REQUESTING THE CITY OR COUNTY INSPECTIONS REQUIRED BY SECTION 110.3 OF THE IBC. SPECIAL INSPECTION IS REQUIRED PER SECTIONS 1704 AND 1705 FOR THE FOLLOWING: 1. EPDXY AND ADHESIVE ANCHORS: A) DURING THE PLACEMENT OF ALL ANCHORS. 2. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR: A) THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATION. B) THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. C) UPON COMPLETION OF THE ASSIGNED WORK THE STRUCTURAL ENGINEER SHALL COMPLETE AND SIGN THE APPROPRIATE FORMS CERTIFYING THAT TO THE BEST OF THEIR KNOWLEDGE THE WORK IS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS, AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. FOR ADDITIONAL INFORMATION ON SPECIAL STRUCTURAL INSPECTIONS, CONTACT THE STRUCTURAL ENGINEER PRIOR TO START OF CONSTRUCTION. JOINT PROTECTION: FOR SEALING PERIMETER JOINTS OF GYPSUM BOARD PARTITIONS TO REDUCE SOUND TRANSMISSION. PROVIDE JOINT SEALANTS FOR INTERIOR APPLICATIONS THAT ESTABLISH AND MAINTAIN AIRTIGHT AND WATER—RESISTANT CONTINUOUS JOINT SEALS WITHOUT STAINING OR DETERIORATING JOINT SUBSTRATES. PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY SEALANT MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCE. DOW CORNING CORPORATION OR APPROVED EQUAL. HOLLOW METAL DOORS AND FRAMES: 14 GAUGE COLD ROLLED STEEL FRAME AND 16 GAUGE DOORS FOR EXTERIOR. 16 GAUGE COLD ROLLED STEEL FRAME AND FOR INTERIOR. CORNER CONSTRUCTION: WELD FULL DEPTH AND FACE, GRIND SMOOTH AND RE—PRIME. WELD INCLUDES FACES, RABBETS, SOFFIT AND STOPS. STANDARD HOLLOW METAL FRAMES: STEELCRAFT MANUFACTURING CO., CINCINNATI, OHIO CURRIES CO., MASON CITY, IOWA CECO CORP., OAKBROOK, ILLINOIS ATTACHMENT TO DRYWALL CONSTRUCTION: MANUFACTURER'S STANDARD COMPRESSION TYPE FOR DRYWALL TYPE FRAME. STEEL OR WOOD STUD TYPE TO ACCOMMODATE FRAME JAMB DEPTH AND FACE DIMENSION ON WELDED TYPE FRAME. FLUSH WOOD DOORS: FLUSH INTERIOR DOORS: SOLID CORE. THICKNESS: 1-3/4 INCHES CORE: WOOD BASED PARTICLE BOARD. SURFACE: MEDIUM DENSITY OVERLAY (MDO) PERFORMANCE DUTY LEVEL: HEAVY DUTY. QUALITY GRADE: PREMIUM. FINISH:PRIME AND PAINT. MOHAWK OR APPROVED EQUAL. GYPSUM BOARD ASSEMBLIES: INTERIOR GYSUM WALLBOARD PANEL SIZE: PROVIDE IN MAXIMUM LENGTHS AND WIDTHS AVAILABLE THAT WILL MINIMIZE JOINTS IN EACH AREA AND CORRESPOND WITH SUPPORT SYSTEM INDICATED. STANDARD GYPSUM BOARD: PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, AVAILABLE PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT NOT LIMITED TO THE FOLLOWING: GEORGIA—PACIFIC GYPSUM LLC; TOUGH ROCK. CORE: 5/8 INCH, TYPE X. LONG EDGE: TAPERED. TRIM ACCESSORIES INTERIOR TRIM: ASTM C1047. MATERIAL: GALVANIZED OR ALUMINUM—COATED STEEL SHEET, ROLLED ZINC, PLASTIC, OR PAPER—FACED GALVANIZED STEEL SHEET. SHAPES: CORNERBEAD: USE AT OUTSIDE CORNERS. LC—BEAD (J—BEAD): USE AT EXPOSED PANEL EDGES. NON—STRUCTURAL METAL FRAMING: METAL STUD FRAMING AND ACCESSORIES AT INTERIOR LOCATIONS. SCAFCO STEEL STUD COMPANY, OR APPROVED EQUAL. ACOUSTICAL PANEL CEIUNG: CEILINGS CONSISTING OF ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS. ARMSTRONG, OR APPROVED EQUAL. ACOUSTICAL PANEL TYPE: CORTEGA 'SECOND LOOK' ACOUSTICAL PANEL COLORS : WHITE SIZE : 24"X48"X3/4" NOMINAL SIZE. CEILING SUSPENSION SYSTEMS USED PRIMARILY TO SUPPORT ACOUSTICAL TILE PANELS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF IBC 2015. CARPET: TILE CARPET DIRECT—GLUED TO SUBSTRATE. MOHAWK COMMERCIAL CARPET — GT157 EMERGING LIGHTS II, COLOR: 898 GALACTIC FUSION BONDED, MANUFACTURED IN ONE COLOR DYE LOT, 24"X24" NOMINAL. COLORS: AS SELECTED FROM MANUFACTURER'S STANDARD COLORS. REDUCER: MERCER IMPERIAL 700. ADHESIVE: AS RECOMMENDED BY MANUFACTURER FOR DIRECT GLUE—DOWN INSTALLATIONS. ENTRANCE MATS: WALK OFF TILE DIRECT—GLUED TO SUBSTRATE. MOHAWK COMMERCIAL CARPET OR APPROVED EQUAL. FIRST STEP II TILE FUSION BONDED, MANUFACTURED IN ONE COLOR DYE LOT, 24"X24" NOMINAL. COLORS: AS SELECTED FROM MANUFACTURER'S STANDARD COLORS. REDUCER: MERCER IMPERIAL 700. ADHESIVE: AS RECOMMENDED BY MANUFACTURER FOR DIRECT GLUE—DOWN INSTALLATIONS. MANUFACTURED PLASTIC—LAMINATE—CLAD CASEWORK: LOWER BASE CABINETS WILSONART — SKYLINE WALNUT 7964K -12S COUNTERTOP DALTILE ONE QUARTZ — FRESH LINENS N066 SOLID SURFACE UPPER WALL HUNG CABINETS WILSONART — PHANTOM ECRU 8212K-8 HARDWARE: AMERLOCK 5" BP36571G10 MONUMENT (CAFE CABINETS) PULLS: WIRE PULLS THROUGH BOLTED FROM BACK SIDE. CATCHING DEVICES: MAGNETIC WITH A MINIMUM 7—POUND PULL. DRAWER SLIDES MAY BE ABS SELF—LUBRICATING SLIDES. SHELF HARDWARE: PROVIDE SELF—LOCKING PINS. FABRICATION TO COMPLY WITH AWI SECTION 1600B. RAISED FLOOR SYSTEM: PROVIDE AND INSTALL RAISED FLOOR SYSTEM BY TATE ACCESS FLOORS OR PRE—APPROVED EQUIVALENT. FLOOR PANELS SHALL BE CONCORE CC1250 (24"x24") UNTOPPED CONCRETE PANELS. PROVIDE BOLTED STRINGER UNDER STRUCTURE AND PEDESTALS IN A BASKET WEAVE CONFIGURATION AS REQUIRED TO SUPPORT THE PANELS. TOTAL RAISED ACCESS FLOOR SYSTEM HEIGHT SHALL BE 1'-2" (FIELD VERIFY). EACH PEDESTAL SHALL BE ANCHORED TO EXISTING CONCRETE SLAB WITH (2) 3/8" DIAMETER KWIK—BOLT TZ ANCHORS EMBEDED 2" (2 3/8" NOMINAL) MINIMUM. VERIFY REQUIRED ANCHOR SIZE WITH PEDESTAL BASE PLATES. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS (INCLUDING SEISMIC ANALYSIS) OF THE RAISED FLOOR SYSTEM PRIOR TO INSTALLATION FOR REVIEW AND APPROVAL. PAINT AND COATING: INCLUDES SURFACE PREPARATION AND FIELD APPLICATION OF PAINTS. ALL PAINT TO SUPPLIED BY: GLIDDEN PROFESSIONAL 22643 83RD AVENUE SOUTH SUITE E&F KENT, WASHINGTON 98032 SURFACES: CORRECT DEFECTS AND CLEAN SURFACES CAPABLE OF AFFECTING WORK OF THIS SECTION. REMOVE OR REPAIR EXISTING COATINGS EXHIBITING SURFACE DEFECTS. PAINT COLOR SCHEDULE: MARK MANUFACTURER COLOR (SIZE) SHEEN LOCATION PT-1 GLIDDEN PROFESSIONAL CRISP LINEN A0057 61YY 89/040 EGGSHELL FIELD COLOR— ALL INTERIOR WALLS AND CEILINGS UNLESS OTHERWISE NOTED. PT -1 GLIDDEN PROFESSIONAL CRISP LINEN A0057 61YY 89/040 LOW LUST DEMOUNTABLE PARTITION DOOR FRAMES PT -2 GLIDDEN PROFESSIONAL ICON GREY A2O12 (OONN 31/000) LOW LUST HOLLOW METAL DOORS AND FRAMES PT -1 GLIDDEN PROFESSIONAL FROST A1842 55YY 80/072 EGGSHELL HALLWAY COLOR — INTERIOR WALLS DOOR HARDWARE: EXTERIOR DOOR (S2) 8 HINGES (4 EACH DOOR) 2 EXIT DEVICE 2 LEVER TRIM 2 RIM HOUSING 2 CONSTRUCTION CORE 2 OVERHEAD STOP 2 SURFACE CLOSER 2 KICK PLATE 1 THRESHOLD 1 GASKETING 1 AUTOMATIC OPENER 2 DOOR SWEEP 1 CARD READER INTERIOR DOOR (100) 8 HINGES (4 EACH DOOR) 2 EXIT DEVICE 2 LEVER TRIM 2 OVERHEAD STOP 2 SURFACE CLOSER 2 KICK PLATE 1 AUTOMATIC OPENER INTERIOR DOORS (100A AND 100B) 3 HINGE 1 LEVER LOCK 1 WALL STOP DEFERRED SUBMITTALS: HAGER VON DUPRIN VON DUPRIN YALE YALE GLYNN—JOHNSON YALE IVES PEMKO PEMKO RECORD—USA PEMKO (BY BOEING) HAGER VON DUPRIN VON DUPRIN GLYNN—JOHNSON YALE IVES RECORD—USA HAGER YALE IVES BB1191 5" X 4-1/2 NRP 9927 36" 996L #6 X US26D 1212 121 OT 104S 4400 8400 10"X34" 151 72" S88D 20' 8100 SERIES 36" 308_PK 26" BB1191 5" X 4-1/2 NRP 9927 36" 996L #6 X US26D 104S 4400 8400 10"X34" 8100 SERIES 36" 1279 4-1/2 X 4-1/2 AU5401LN X US26D WS402CCV SHOP DRAWING SUBMITTALS REQUIRED BY THESE GENERAL ARCHITECTURAL NOTES WHICH CONTAIN DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER OTHER THAN THE ENGINEER OF RECORD SHALL BE SUBMITTED PRIOR TO CONSTRUCTION TO THE BUILDING OFFICIAL FOR REVIEW. THE DOCUMENTS WILL FIRST BE REVIEWED BY THE OWNER AND ENGINEER OF RECORD AND DETERMINED TO BE IN GENERAL CONFORMANCE WITH THE BUILDING DESIGN. THESE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE BUILDING OFFICIAL HAS APPROVED THEIR DESIGN AND SUBMITTAL DOCUMENTS. THE FOLLOWING ITEMS SHALL BE SUBMITTED PER THIS SECTION: AUTOMATIC SPRINKLER SYSTEM I REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 • City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 RECEIVED CITY OF TUKWILA NOV 0 9 2011 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET PHONE: (253) 474-9449 http:l/www.sItts•hIII.engineers.coml I TACOMA, WA. 98409 I FAX: (253) 474-9449 Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 Q� BOE/NG° 6� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE GENERAL DESIGN NOTES CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED APPROVED TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A2 JOB NO. 33658 COMP NO. DWG NO. 09-08—A2 10:59:12 PM N 0 C co COce U 1'-10" CIO 13 383'-8" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" -10" .11 IAS 0 00 N LEGE\ D SCHEDULE: EXIT — — — — AREA IN SF NUMBER OF OCCUPANTS TO EXIT OCCUPANCY FACTOR PER IBC TABLE 1004.1.2 EXIT (3'-0" WIDE (MIN.) DOOR WITH EXIT DEVICE) NUMBER OF OCCUPANTS TO EXIT EXIT SIGN WITH DIRECTIONAL ARROW (PER 2015 IBC SECTION 1013). CONTRACTOR TO PROVIDE EXIT SIGN PLACEMENT IN SUCH AWAY THAT NO POINT IN AN EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS MORE THAN 100 FEET OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. 1013.4 RAISED CHARACTER AND BRAILLE EXIT SIGNS:A SIGN STATING 'EXIT' IN RAISED CHARACTERS AND BRAILLE AND COMPLYING WITH ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY, AN EXIT RAMP, AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. EXIT ACCESS TRAVEL fl EG\ESS COR DORS 760 GE\PAL \OT =S: 1. EXISTING EXITING SYSTEM IS TO REMAIN UNCHANGED. ADDING THE NEW ENTRY VESTIBULE IS TO ACCOMMODATE THE NEW CONFERENCE ROOM EXITING ONLY. c•• EGRESS ORIDORS Oil IA r-� SCALE: 1/16" = 1'-0" 00 N O 03 N C /1 \STUCTI3\ \CIES: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 RECEIVED CITY OF TUKWILA NOV 0 9 2011 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts-h111.engineers.coml Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RELOCATE JSF LEVEL 4 J#780347-00 GMM 03.18.98 B PLANNING OFFICE MOD. J#701620-00 TWH 6.16.00 C LOBBY RENOVATION 33658 SITTS BKL 11.09.17 eL.0 01 w, ° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN EDDIE P. DUARTE CHECKED DATE 08.16.93 SUBTITLE EXITING PLAN CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER LOBBY RENOVATION BUILDING 9-08.1 COL. A -F/1-20 DEV. CENTER, WA SHEET 1A01 JOB NO. DWG NO. 737332-02 9-08-1A01 COMP NO. HO WA/11.01.99/15:07 (5 Al2 A32B 4 Al2 A35B (A) I� OFFICE OFFICE OFFICE OPEN SPACE OFFICE 1CS OFFICE OFFICE CONFERENCE 1CS OPEN OFFICE m N 1JS FEC 1HS 0 0 U 1AS 0 0 cc 0 U ES ES -}1-1S 0 0 Al A MEN HS -6 FS A MEN JAN STOR SHAFT ABOVE M 13 Al2 A36 A TEL RM 2CS 2CS A O FEC Al2 A72 tBNFERENCE ROOM OPEN OFFICE SPACE F22 WHITE ROOM IBC 2096 B OCCUPANCY- OFFICE 1290 S.F., 13 OCCUPANTS AT 100 S.F PEER OCCUPANT PER TABLE 1004.1.1 JS 2CS r I FURS EL ATOR SHAF ELECT RM 2CS TEL RM U • N 1 1JS JS 1CS J 9 1E 1A 2CS 1A [ FEC Al2 A72 VTC 1Al2I GALLERY 5 C 14 Al2 A35B VTC LOBBY (B 1Al2R A515 2FS OFFICE CONFERENCE 2CS Rr 141A II B A 1Al2 A515 1Al2 A515 EQUIP. RM THIS WALL J�STC 50 ONLY R 141 B0 2JS 1CS OFFICE Al2A 5B SYM L REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE F22 WHITE ROOM RECONFIGURATION J#160652-00 LMC TWH 02.28.07 F REMODEL 9-08 LOBBY J#190070-00 GMM 8.16.99 M LOBBY RENOVATION 33658 SITTS BKL 11.09.17 G PLANNING OFFICE MOD. J#701620-00 TWH 6.16.00 C INSTALL DISPLAY CASE J#170059-00 MRM 10.09.97 H VTC ROOM REVISIONS J#534875-00 TWH TWH 09.29.03 D E INSTALL DISPALY CASE (REVISIONS) INSTALL AMS IN JSF AREAS J#170059-00 J#785146-01 MRM 5.5.99 J LOCK DOWN 9-08.1 J#546430-00 FOA FOA 07.19.04 MRM 11.25.98 K LOCK DOWN 11D15 J#546777-00 TWH TWH 02.25.05 gLBOE/NG ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M.DITTMAR CHECKED Al2 A35B 19 DATE 11.06.97 SUBTITLE LEGE I I 2FS D/SCHE PARTITION TYPE. SEE SHEET A-37 ULE: DEMOUNTABLE PARTITION GE\RAL \CTES: 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK AND STAGING AREAS CLEAN AND UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS AND MATERIALS FROM THE WORK AREA. 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK CO\S-RUCTIO\ \OTES: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 FLOOR PLAN 0 14 0- <EY PLA\ SCALE: NONE 4 8 16 24 SCALE: 1/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts-h111.engineers.coml Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED BY DEPT. DATE ENGINEER M.MILLER CHECKED 11.06.97 APPROVED APPROVED TITLE LOBBY RENOVATION BUILDING 9-08.1 ARCHITECTURAL MASTER COL. A -F/14-20 DEV. CENTER, WA SHEET 1Al2 JOB N0. 160652-00 COMP NO. DWG NO. 9-08-1Al2 FT814C: 02/27/07 09:16 SYM • 0 0 0 0 • Immo 0 • • I] • 11111M=18 0 0 • //■ 0 m -a. !UUU mau isey4 INN -Ez± -0- f II • • 0 0 • II- o-LMMIll - • O 0 -iii■■ ° IRE= II • U Ulm • 0 • ca 0 • • • ,,, Co 0 0 0 G■ 0 • • • ■� 11111■■ 0 ■■■■■■ ® ®� m ■�'��� �� � ■ 1111■■■■ ■ii 1111■■ 1 �1�"# ■■■■■■ 1 ■.t 11111131111 ® ® .11■\jam IIr4VU..$ m■■■■' ■r■■■\r__■■■■ 1111■■■Il .tj::__::::�� ° 1111 ° p ■■■■1► \P ■■■■■■11 ° M—II=-II111 ■1111■■■L-.1■■■■UU■ 11111111111111111111118 • • • I MO IIS p Firmormi.,4 i %m3 G 6 0 I ECM 111111=1111111111Mr°© 0 0 II ° ■1■ 0 II 0 1■1111■IIIOI REVISION BY APPROVED DATE SYM EFLECTED CEILI\G PLA\ SCALE: 1/8" = 1'-0" REVISION BY APPROVED DATE A LOBBY RENOVATION 33658 SITTS BKL 11.09.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN M. DITTMAR CHECKED M. MILLER ENGINEER DATE 10-10-97 SUBTITLE LEGE\D/SCHEDULE 0 -301- 0 RETURN AIR GRILLE 2 x2' RETURN AIR GRILLE 1'x1' AIR DIFFUSER 4' LINEAR DIFFUSER POWER POLE FIRE PROTECTION SPRINKLER HEAD 2'x4' FLUORESCENT LIGHT 2'x2' FLUORESCENT LIGHT EXIT LIGHT (WITH DIRECTIONAL ARROW IF REQUIRED) SPEAKER 1'x4' FLUORESCENT LIGHT (RECESSED) 1'x8' FLUORESCENT LIGHT (SURFACE MOUNT) RECESSED CAN LIGHT FIXTURE SMOKE DETECTOR GE\PAL CTES: CO\STUCTI \ \OTES: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 REFLECTED CEILING PLAN 0 <EY PLA\ SCALE: NONE 4 8 16 24 MI MI IIIIII SCALE: 1/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-englneers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM CURRENT REVISION 33658 SYMBOL TITLE LOBBY RENOVATION CHECKED APPROVED APPROVED BUILDING 09-008.1 COL. A—F/14-20 ARCHITECTURAL MASTER 1A282 JOB NO. DATE 11.09.17 COMP NO. DEV. CENTER, WA DWG NO. 09-008-1A282 10:14:24 AM MG124D: 3/20/2013 08) I 0 t N Nw 30'-0" SHIELDED LABYRINTH 100 6'-4" 4'-4" LOBBY 101 \\\\\\\\\\\\\\\ TAAATAA N \\ \� \\\\ \\\\ \\\\ E\LACE FLOO PLA\ .EVOVAL SCALE: 3/8" = 30'-0" ENTRY 111 N LECEv/scHEDuLE: LOBBY AS SHOWN ON PLAN INDICATES NEW ROOM. SEE ROOM FINISH 3A451X SCHEDULE ON DRAWING A370. GE\RAL \ OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. CO\STRUCTIO\ COTES: REMOVE EXISTING RAISED FLOOR SYSTEM IN THE ENTIRE AREA. REMOVE EXISTING ECCOSORB WALL ABSORBERS AND FABRIC WALL PANELS. REMOVE PORTION OF EXISTING FABRIC WALL PANELS AS REQUIRED TO ALLOW FOR INSTALLATION OF NEW DOUBLE DOOR. REMOVE AND RELOCATE EXISTING AUTOMATIC DOOR OPENER AND CONTROL BOX. RELOCATE TO NEW 6" METAL STUD WALL. REMOVE EXISTING DOOR. .EFRE\CE DAWI \GS: I 0 N REMOVAL 1Al2 A450R C gi REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21. 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS. PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 2 6 8 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL ■ SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sItts-h111-englneers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM 10:59:12 PM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE ENLARGED FLOOR PLAN - REMOVAL CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET 1A450R JOB N0. 33658 COMP NO. DWG NO. 09-08-1A450R ///,i%/,I / / / ,% / /%i/,/i/i//i AN / /mws L 1 / d 1 /O NAV N LECEv/scHEDuLE: LOBBY AS SHOWN ON PLAN INDICATES NEW ROOM. SEE ROOM FINISH 3A451X SCHEDULE ON DRAWING A370. GE\RAL \ OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. CO\STRUCTIO\ COTES: REMOVE EXISTING RAISED FLOOR SYSTEM IN THE ENTIRE AREA. REMOVE EXISTING ECCOSORB WALL ABSORBERS AND FABRIC WALL PANELS. REMOVE PORTION OF EXISTING FABRIC WALL PANELS AS REQUIRED TO ALLOW FOR INSTALLATION OF NEW DOUBLE DOOR. REMOVE AND RELOCATE EXISTING AUTOMATIC DOOR OPENER AND CONTROL BOX. RELOCATE TO NEW 6" METAL STUD WALL. REMOVE EXISTING DOOR. .EFRE\CE DAWI \GS: I 0 N REMOVAL 1Al2 A450R C gi REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21. 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS. PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 2 6 8 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL ■ SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sItts-h111-englneers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM 10:59:12 PM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE ENLARGED FLOOR PLAN - REMOVAL CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET 1A450R JOB N0. 33658 COMP NO. DWG NO. 09-08-1A450R 18 0 I 0 N LOBBY NA STORAGE ROOM CONFERENCE ROOM VESTIBULE CONFERENCE xxxxxxxxxxxxxxxxxxxxxxxxxxxxx .xxxx E\LAGED FLOO SCALE: 3/8" = PLA\ N N N N N N LECE\D/SCHEDULE: RAISED FLOOR SYSTEM PER GENERAL DESIGN NOTES ON SHEET A2. c 0 N 18 LOBBY 3A451X 0 G AS SHOWN ON PLAN INDICATES NEW ROOM. SEE ROOM FINISH SCHEDULE ON DRAWING A350. AS SHOWN ON PLAN INDICATES NEW DOOR. SEE DOOR TYPE SCHEDULE ON DRAWING A350. AS SHOWN ON PLAN INDICATES 6" STEEL STUD WALL WITH 5/8" GWB ON BOTH SIDES. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 6" STEEL STUD WALL WITH 5/8" GWB ON ONE SIDE. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 3 5/8" STEEL STUD WALL WITH 5/8" GWB ON BOTH SIDES. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 3 5/8" STEEL STUD WALL WITH 5/8" GWB ON ONE SIDE. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. -\FRAC \OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL RAISED FLOOR SYSTEM PER GENERAL DESIGN NOTES ON SHEET A2 AND PER SECTION A/A501. SEE ROOM FINISH SCHEDULE ON SHEET A370 FOR ADDITIONAL INFORMATION. CASEWORK PER ELEVATION A/A500. RELOCATED EXISTING AUTOMATIC DOOR OPENER AND CONTROL BOX. COORDINATE EXACT LOCATION WITH ELECTRICAL DRAWINGS. 6. SEE DETAILS 3/A501, 4/A501, AND 5/A501 FOR ADDITIONAL STEEL STUD WALL FRAMING INFORMATION. CC\S-RUCTIO\ \OTES: FILL IN EXISTING 6' WIDE FIRE DOOR WITH METAL STUD WALL. MATCH EXISTING WALL THICKNESS. PROVIDE AND INSTALL DOOR AND FRAME. SEE DOOR SCHEDULE 1/A350 FOR ADDITIONAL INFORMATION. EFRE\CE DV\WI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER I1 1Al2 A450 REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 0 o� io 0- <EY PLA\ 2 4 6 8 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts•h111-engineers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 gi...,mEtrirmr"t ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE ENLARGED FLOOR PLAN CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET 1A450 JOB NO. 33658 COMP NO. DWG NO. 09-08-1A450 10:59:12 PM I` 0 c co ,,/ ,, , ,/ , , ......., , , , , . AFAIWAr. ....„:„7,„,„ A , 7, , . , / ,/ , ,/ , , , , /jigs,/ , , AMMOMN, / .MrAMMr E\LAGED FLOO SCALE: 3/8" = PLA\ N N N N N N LECE\D/SCHEDULE: RAISED FLOOR SYSTEM PER GENERAL DESIGN NOTES ON SHEET A2. c 0 N 18 LOBBY 3A451X 0 G AS SHOWN ON PLAN INDICATES NEW ROOM. SEE ROOM FINISH SCHEDULE ON DRAWING A350. AS SHOWN ON PLAN INDICATES NEW DOOR. SEE DOOR TYPE SCHEDULE ON DRAWING A350. AS SHOWN ON PLAN INDICATES 6" STEEL STUD WALL WITH 5/8" GWB ON BOTH SIDES. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 6" STEEL STUD WALL WITH 5/8" GWB ON ONE SIDE. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 3 5/8" STEEL STUD WALL WITH 5/8" GWB ON BOTH SIDES. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. AS SHOWN ON PLAN INDICATES 3 5/8" STEEL STUD WALL WITH 5/8" GWB ON ONE SIDE. COORDINATE TRIM AND BASE MOLDING DESIGN WITH BOEING REPRESENTATIVE. SEE DETAILS 8/A500 AND 9/A500 FOR ADDITIONAL INFORMATION. -\FRAC \OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL RAISED FLOOR SYSTEM PER GENERAL DESIGN NOTES ON SHEET A2 AND PER SECTION A/A501. SEE ROOM FINISH SCHEDULE ON SHEET A370 FOR ADDITIONAL INFORMATION. CASEWORK PER ELEVATION A/A500. RELOCATED EXISTING AUTOMATIC DOOR OPENER AND CONTROL BOX. COORDINATE EXACT LOCATION WITH ELECTRICAL DRAWINGS. 6. SEE DETAILS 3/A501, 4/A501, AND 5/A501 FOR ADDITIONAL STEEL STUD WALL FRAMING INFORMATION. CC\S-RUCTIO\ \OTES: FILL IN EXISTING 6' WIDE FIRE DOOR WITH METAL STUD WALL. MATCH EXISTING WALL THICKNESS. PROVIDE AND INSTALL DOOR AND FRAME. SEE DOOR SCHEDULE 1/A350 FOR ADDITIONAL INFORMATION. EFRE\CE DV\WI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER I1 1Al2 A450 REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 0 o� io 0- <EY PLA\ 2 4 6 8 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts•h111-engineers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 gi...,mEtrirmr"t ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE ENLARGED FLOOR PLAN CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET 1A450 JOB NO. 33658 COMP NO. DWG NO. 09-08-1A450 10:59:12 PM I` 0 c co 30'-0" •�� LIrvr-‘1r-- 4 I/ 1 ir 4k-wl - _1_ W-1- i‘ N\ -11-14111111142 I , 11 11 11 A 11111111,Y IM11111 111 III 61.WWWWWWWWWow- wiljj_11, i 141 hiMmIllZ7-- lil ‘I" 011111 1110.11}11Millr.-14 loi I- I - 0 0 \ \ 0 0 FA IL 11 Nor s1r1 El1P11MAAAti..1 LAMM mi 01 0 li0 ALLEItiiiiME v•' Oki OFr"revril $' 0 0 ri --v-- -,r-y--4E FA- -omilm--.....0 1 -_, 1 41n 1” I 41 MI Ata.............._ lw itiTipitiTiplielTYTTYYTTYYTTI? E\LAGEJ EFLECTED CEILI\G PLA\ �E SCALE: 3/8" = V-0" V OVAL 30'-0" (c) REMOVAL REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 Q�BOE/NGm ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie DATE 08.22.17 08.22.17 08.22.17 08.22.17 1A282 A451R LEGE\J/SCHEDULE: GE \ RAL \OTES: 1. SEE GENERAL ARCHITECTURAL NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. CO\ST�UCTIO\ \OTES: REMOVE ECCOSORB CEILING ABSORBERS IN THE ENTIRE ENTRY. REMOVE AND RELOCATE EXISTING FIRE SPRINKLERS IN THE ENTIRE ENTRY. COORDINATE WITH MECHANICAL DRAWINGS. EXISTING CEILING TO REMAIN. EFRE\CE DAWI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 Q <EY PLA\ 2 4 0 O 6 8 1111111111111111 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sItts•hIU-engineers.com/ Project No.: 18001 roject Mgr.: BKL Pro j. Engineer: BRL roj. Drafter: SLM SUBTITLE ENLARGED REFLECTED CEILING PLAN - REMOVAL CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED APPROVED TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SEA 1A451R JOB NO. 33658 COMP NO. DWG NO. O9 -08--1A451 R 10:59:12 PM SMCCARTHY: 8/16/2017 18 1 N N \-\ 30'-0" 0 0 0 0 0 0 0 0 0 XXXXXXXXXXXXXXXXXXX 0 XXXXX XXXXXXX XXX 0 0 \ ""' E\LAGED EELECTED CEILI\G PLA\ SCALE: 3/8" = Nt /// 0 0 0 \\\\\\\\\\\\\\\\\\\\\\\\\\\\ N 30'-0" N N N N N N 1A282 A451 REVISION 1 : CORRECTIONS 19 LEGE v/scHEDAE: AS SHOWN ON PLAN INDICATES NEW 2'x2' ACOUSTICAL TILE CEILING GRID, SEE "GAN" GENERAL ARCHITECTURAL NOTES AND DETAIL 1/A50 FOR ADDITIONAL INFORMATION. 0 AS SHOWN ON PLAN INDICATES NEW RECESSED CAN LIGHT FIXTURE. COORDINATE WITH ELECTRICAL AND MECHANICAL DRAWINGS. GE\RAL \OYES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ACOUSTICAL TILE CEILING GRID. FOR ADDITIONAL INFORMATION SEE DETAIL 1/A500. CO\S-RUCTIC\ \OYES: 'EERE\CE DAWI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 <EY PLA\ 2 4 6 8 SCALE: 3/8"=1'-0" SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sltts-hill-engineers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM 10:59:12 PM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 gL,m,":Erirm.ff ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE ENLARGED REFLECTED CEILING PLAN CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET 1A451 JOB NO. 33658 COMP NO. DWG NO. 09-08-1A451 FOR DOOR HARDWARE SEE SHEET A2 FOR DOOR TYPE SCHEDULE SEE 2/A350. FOR DOOR FRAME SCHEDULE SEE 3/A350. NOTES: 1. DOOR SIZES INDICATED ARE NOMINAL DIMENSIONS. REFER TO DOOR AND HARDWARE SPECIFICATIONS FOR COORDINATION. 2. REFER TO DOOR TYPES SCHEDULE, DOOR FRAME TYPES AND SPECIFICATION FOR HARDWARE GROUPS. 3. DOOR ASSEMBLIES SHALL MEET THE FOLLOWING ACCESSIBILITY REQUIREMENTS: 3.1. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5.0 LBS. (PER IBC). 3.2. MOUNTING HEIGHTS OF ACCESSIBLE DOOR OPERATION HARDWARE SHALL COMPLY WITH IBC. 3.3. DOOR OPERATIONS AND DOOR HARDWARE SHALL COMPLY WITH IBC SECTION 1008.19. 3.4. SEE DETAIL 7/A502 FOR ADDITIONAL INFORMATION. 4. DOOR ASSEMBLIES SHALL MEET THE FOLLOWING FIRE—RATED REQUIREMENTS: 4.1. EXCEPT AS OTHERWISE REQUIRED BY LOCAL BUILDING CODES, THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL FIRE DOOR ASSEMBLIES IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL FIRE D0CH SCHEDULE PROTECTION ASSOCIATION PAMPHLET, NFPA 80. THIS INCLUDES SWINGING DOORS, HORIZONTAL SLIDING DOORS, HOISTWAY DOORS FOR ELEVATORS, ACCESS DOORS, AT THE LOCATION WHERE INDICATED. LOCAL BUILDING CODES GOVERN, IF ANY DIFFERENCES EXIST BETWEEN THESE CODES AND THE NFPA FOR ANY OF THE ABOVE INSTALLATIONS. 4.2. ALL REQUIRED FIRE DOORS SHALL BE PROVIDED WITH A NON—COMBUSTIBLE THRESHOLD, EXCEPT 20 MINUTE DOORS. 4.3. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED WITH THE SAME RATING. 4.4. CLOSERS SHALL BE PROVIDED ON LABELED DOORS. 5. PANIC HARDWARE REQUIRED. 6. SEE DETAIL 11/A500 FOR HARDWARE AND SIGNAGE DETAIL. 7. REPLACE EXISTING DOOR AND FRAME WITH NEW IN EXISTING OPENING — VERIFY SIZE. ABBREVIATIONS: FF FACTORY FINISH HM HOLLOW METAL PT PAINT WD WOOD SCALE: N.T.S. PER CHS EDUL� PER SCHEDULE PER CHEDUL PER SCHEDULE t 1/4" SAFETY GLASS (CLEAR) 0 PER SCHEDULE PER SCHEDULE 1/4" SAFETY GLASS (CLEAR) PER SCHEDULE PER SCHEDULE j� 1 1A450IA350 1" INSULATED SAFETY GLASS (CLEAR) F N (FLUSH SOLID DOOR) (FLUSH SIDE LITE DOOR) D00TYPE SCH D U LE D (DOUBLE FLUSH HALF LITE DOOR) DF (DOUBLE FLUSH FULL LITE DOOR) SCALE: N.T.S. PER SCHEDUL PER SCHEDULE .11 2" PER SCHEDULE 2'-0" PER SCHEDULE 2'—O" IN 1/4" SAFETY GLASS (CLEAR) 1 L 1 A350 �0 FRAME TYPE 1 ESA VE SCHEDULE FRAME TYPE 2 SCALE: N.T.S. (3 A350 ROOM FINISH SCHEDULE DOOR SCHEDULE DOOR FLOOR FRAME HARDWARE GROUP DETAILS NOTES NUMBER SIZE TYPE THICKNESS MATERIAL FINISH FIRE RATING TYPE MATERIAL FINISH HEAD JAMB THRESHOLD 100 (2) 3'-0" x 7'-0" D 1 3/4" WD FF — 2 HM PT — 10/A500 10/A500 — 1, 2, 3, 4, 5, 6 100A 3'-0" x 7'-0" N 1 3/4" WD FF — 1 HM PT — 10/A500 10/A500 — 1, 2, 3, 4, 6 100B 3'-0" x 7'-0" F 1 3/4" WD FF — 1 HM PT — 10/A500 10/A500 — 1, 2, 3, 4, 6 S2 (2) 3'-0" x 7'-0" DF 1 3/4" HM FF — 2 HM PT — — — — 1, 2, 3, 4, 5, 6, 7 FOR DOOR HARDWARE SEE SHEET A2 FOR DOOR TYPE SCHEDULE SEE 2/A350. FOR DOOR FRAME SCHEDULE SEE 3/A350. NOTES: 1. DOOR SIZES INDICATED ARE NOMINAL DIMENSIONS. REFER TO DOOR AND HARDWARE SPECIFICATIONS FOR COORDINATION. 2. REFER TO DOOR TYPES SCHEDULE, DOOR FRAME TYPES AND SPECIFICATION FOR HARDWARE GROUPS. 3. DOOR ASSEMBLIES SHALL MEET THE FOLLOWING ACCESSIBILITY REQUIREMENTS: 3.1. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5.0 LBS. (PER IBC). 3.2. MOUNTING HEIGHTS OF ACCESSIBLE DOOR OPERATION HARDWARE SHALL COMPLY WITH IBC. 3.3. DOOR OPERATIONS AND DOOR HARDWARE SHALL COMPLY WITH IBC SECTION 1008.19. 3.4. SEE DETAIL 7/A502 FOR ADDITIONAL INFORMATION. 4. DOOR ASSEMBLIES SHALL MEET THE FOLLOWING FIRE—RATED REQUIREMENTS: 4.1. EXCEPT AS OTHERWISE REQUIRED BY LOCAL BUILDING CODES, THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL FIRE DOOR ASSEMBLIES IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL FIRE D0CH SCHEDULE PROTECTION ASSOCIATION PAMPHLET, NFPA 80. THIS INCLUDES SWINGING DOORS, HORIZONTAL SLIDING DOORS, HOISTWAY DOORS FOR ELEVATORS, ACCESS DOORS, AT THE LOCATION WHERE INDICATED. LOCAL BUILDING CODES GOVERN, IF ANY DIFFERENCES EXIST BETWEEN THESE CODES AND THE NFPA FOR ANY OF THE ABOVE INSTALLATIONS. 4.2. ALL REQUIRED FIRE DOORS SHALL BE PROVIDED WITH A NON—COMBUSTIBLE THRESHOLD, EXCEPT 20 MINUTE DOORS. 4.3. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED WITH THE SAME RATING. 4.4. CLOSERS SHALL BE PROVIDED ON LABELED DOORS. 5. PANIC HARDWARE REQUIRED. 6. SEE DETAIL 11/A500 FOR HARDWARE AND SIGNAGE DETAIL. 7. REPLACE EXISTING DOOR AND FRAME WITH NEW IN EXISTING OPENING — VERIFY SIZE. ABBREVIATIONS: FF FACTORY FINISH HM HOLLOW METAL PT PAINT WD WOOD SCALE: N.T.S. PER CHS EDUL� PER SCHEDULE PER CHEDUL PER SCHEDULE t 1/4" SAFETY GLASS (CLEAR) 0 PER SCHEDULE PER SCHEDULE 1/4" SAFETY GLASS (CLEAR) PER SCHEDULE PER SCHEDULE j� 1 1A450IA350 1" INSULATED SAFETY GLASS (CLEAR) F N (FLUSH SOLID DOOR) (FLUSH SIDE LITE DOOR) D00TYPE SCH D U LE D (DOUBLE FLUSH HALF LITE DOOR) DF (DOUBLE FLUSH FULL LITE DOOR) SCALE: N.T.S. PER SCHEDUL PER SCHEDULE .11 2" PER SCHEDULE 2'-0" PER SCHEDULE 2'—O" IN 1/4" SAFETY GLASS (CLEAR) 1 L 1 A350 �0 FRAME TYPE 1 ESA VE SCHEDULE FRAME TYPE 2 SCALE: N.T.S. (3 A350 ROOM FINISH SCHEDULE ROOM N0. ROOM NAME FLOOR NORTH EAST SOUTH WEST CEILING NOTES BASE WALL BASE WALL BASE WALL BASE WALL MAT'L H IG T 100 VESTIBULE F -1/F-5 B-1 W-1 B-1 W-1 B-1 W-1 B-1 W-1 C-1 9'-0" F-3 100A CONFERENCE ROOM F -3/F-5 B-1 W-1 B-1 W-1 B-1 W-1 B-1 W-1 C-1 9'-0" 100B STORAGE F-5 B-1 W-1 B-1 W-1 B-1 W-1 B-1 W-1 C-1 9'-0" A fi�'3x �y�x�U ---CEILING--- C-1 SUSPENDED ACOUSTICAL PANEL FACTORY FINISH (FE) A FOR MATERIAL FINISH SCHEDULE SEE 5/A350. 001V EI\ISH SCHEDULE SCALE: N.T.S. A450 A350 NATHIAL FI\ISH SCHEDULE SCALE N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 A350 SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM 10:59:12 PM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 ei 1;1 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE SCHEDULES CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A350 JOB NO. 33658 COMP NO. DWG NO. 09-08—A350 C CD MATERIAL FINISH SCHEDULE KEY MATERIAL FINISH NOTES ---BASE--- B-1 RESILIENT WALL BASE FACTORY FINISH (FE) ---FLOOR--- F-1 ENTRANCE MAT FACTORY FINISH (FF) F-3 ,C'a . •r ► • F-5 RAISED FLOOR SYSTEM FACTORY FINISH (FF) ---WALL--- W-1 GYPSUM WALLBOARD (GWB) PAINT A ---CEILING--- C-1 SUSPENDED ACOUSTICAL PANEL FACTORY FINISH (FE) NATHIAL FI\ISH SCHEDULE SCALE N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 A350 SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM 10:59:12 PM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 ei 1;1 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE SCHEDULES CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A350 JOB NO. 33658 COMP NO. DWG NO. 09-08—A350 C CD 4 cc 0 CV 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" ELEVArio\ A450 A370 LEGE \D/SCHEDULE GE\ HAL \OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. COUNTER TOP. CONFIGURATION LOWER BASE CABINETS 2-0D WITH AS SHOWN ON DRAWINGS. SEE SHEET A2 FOR ADDITIONAL INFORMATION. UPPER WALL HUNG CABINETS (1'-0"D). CONFIGURATION AS SHOWN ON DRAWINGS. SEE SHEET A2 FOR ADDITIONAL INFORMATION. CO\S-RUCTIO\ \OTES: EFRE\CE DAWI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 2 RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER 4 6 8 SCALE: 3/8"=1' SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts-h111-engineers.coml Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 Q� BOE/NG C' - ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED 8. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED DATE SUBTITLE 08.22.17 08.22.17 INTERIOR ELEVATIONS CURRENT REVISION 33658 SYMBOL DATE 11.09.17 08.22.17 08.22.17 APPROVED TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A370 JOB NO. 33658 COMP NO. DWG NO. 09-08—A370 10:59:12 PM SMCCARTHY: 8/16/2017 • / / / N \kJ/ N N / \/\ / N Nth/... \ / N NY / N \0/..:......\kJ/.• N / N / N/ / N N / N / u / N '1J/ N N / � / / 0 \ \ \/ . \ I vice/ / /\ / I \ \/ \ N D vice/ / / /N 1 \ \ \/ N 1 vN/ / / %\ / D \ \ \/ N D\\,/ / / %\ / \ \ \/ N H vN / / / 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" 2'-8 1/4" ELEVArio\ A450 A370 LEGE \D/SCHEDULE GE\ HAL \OTES: 1. SEE GENERAL DESIGN NOTES "GDN" ON DRAWING A2 FOR ADDITIONAL INFORMATION. 2. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. COUNTER TOP. CONFIGURATION LOWER BASE CABINETS 2-0D WITH AS SHOWN ON DRAWINGS. SEE SHEET A2 FOR ADDITIONAL INFORMATION. UPPER WALL HUNG CABINETS (1'-0"D). CONFIGURATION AS SHOWN ON DRAWINGS. SEE SHEET A2 FOR ADDITIONAL INFORMATION. CO\S-RUCTIO\ \OTES: EFRE\CE DAWI\GS: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 0 2 RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER 4 6 8 SCALE: 3/8"=1' SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http:/lwww.sItts-h111-engineers.coml Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 Q� BOE/NG C' - ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED 8. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED DATE SUBTITLE 08.22.17 08.22.17 INTERIOR ELEVATIONS CURRENT REVISION 33658 SYMBOL DATE 11.09.17 08.22.17 08.22.17 APPROVED TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A370 JOB NO. 33658 COMP NO. DWG NO. 09-08—A370 10:59:12 PM SMCCARTHY: 8/16/2017 NOTE: 1. SEE DETAIL 3/A500 AND 7/A500 FOR SEISMIC RESTRAINT DETAIL. (2 A500 I 1 A500 I I A500 FOR TYPICAL LIGHT SUPPORT DETAIL A500 . • /f . (3 A500 (6 A500 A500 SIM. (-67 A500 ACOUSTICAL PA\EL SUSPE\SIO\ DETAIL SCALE: N.T.S. 3/4" //////// PERIMETER ANGLE / FIRE PROTECTION LINE W/ FLEXIBLE HOSE HEAD CONNECTION LINE — 1/4" CLEARANCE FOR ALL CEILING PENETRATIONS. 1/8" CLR. DUCTS o5)) 1/8" CLR. CEILING PANEL ESCUTION COVER SPRINKLER HEAD (TYPE VARIES) r ACOUSTICAL TILE PE\ERATIO\ DETAIL 1A4511500 SCALE: N.T.S. PROVIDE CONNECTION TO WALL STRUCTURE PER MANUFACTURER'S RECOMMENDATION AND STANDARD DETAILS PANEL NON—FIXED END 2" ACOJSTICAL PA\EL DETAIL SCALE: N.T.S. TOP OF STUD WALL PARTITION BRACING SEE DETAIL 2/A501 IIIn111II1111111J CONSTRUCTION PER WALL TYPE SCHEDULE Awl Ow - TC' OF PATITIO\ DETAIL + 1O'-6" A.F.F. S.A.C. OR GWB WHERE OCCURS AS SCHEDULED 3/4" FIXED END r—h 2" A500 r\ PROVIDE CONNECTION TO WALL STRUCTURE PER MANUFACTURER'S \ RECOMMENDATION AND STANDARD �� DETAILS PERIMETER ANGLE \ (5ACOUSTICAL PA\EL DETAIL A500 SCALE: N.T.S. 9 SCALE: 1 1/2" = 1'-0" 1A450 A500 DOOR — SEE SCHEDULE 2" 7Ji CONTINUOUS SEALANT BEAD 5/8" GYPSUM BOARD ON METAL STUDS (SEE FLOOR PLAN) DOUBLE METAL STUDS CONTINUOUS SEALANT BEAD HOLLOW METAL FRAME i\rPiN DOO HEAD (JA SCALE N.T.S. V3 SIM.) PROVIDE HILTI KWIK HUS—EZ OR SIMPSON TITEN HD SCREW ANCHOR TO PREVENT UPLIFT OF CEILING DURING SEISMIC EVENT: EXTEND STRUTS TO FIT TIGHT TO CEILING GRID AND STRUCTURE ABOVE, THEN INSTALL TWO FASTENERS TO SECURE ONE STRUT TO THE OTHER. TUBES SHALL LAP ONE ANOTHER 4" MIN. DIAGONAL HANGER WIRES AT APPROX. 45 DEG. (TYP) MAX. FROM HORIZ. 1) SLOT END OF CONDUIT TO FIT OVER CEILING RUNNER 1" MIN. ANCHOR TO STRUCTURE ABOVE 1/2" MIN. DIA. SEISMIC COMPRESSION POST AT 12'-0" O.C. EACH WAY. START FIRST POST POINT WITHIN 6'-0" FROM EACH WALL, PROVIDE AND INSTALL POSTS PER IBC AND NWBC FIELD TECH DOC #401 REQUIREMENTS. HANGER WIRE 3/4" MIN. DIA. ELECTRIC CONDUIT STRUT MAIN RUNNER CROSS RUNNER SEISMIC CEILI\G 'ES-RAI\T DETAIL SCALE: N.T.S. 8" MAX. MAI N RUNNER 6 1 HANGER WIRE AT 4 FEET O.C. MAX. +/— 10 DEG. MAX. N 3/4" WALL CONDITION (6CEILI\G EDGE SEIS A500 SCALE: N.T.S. ETAI L � o A350 A500 SPACER BAR TO PREVENT PERIMETER COMPONENTS FROM SPREADING APART V I C . EST'AI \T 0 K I\ L— _1 g 0 0 M J 1'-6" 2'-0" PREFERRED \TR10; DOC HA]WAE A\7 SIG\AGE DETAIL A500 DETAIL n A500 ADJUST TO CLOSE FROM OPEN POSITION OF 70' TO 3" FROM LATCH IN THREE SECONDS MAGNETIC DOOR HOLDER, LOCATE 80" A.F.F. & LOCATE 6" FROM EDGE (STRIKE) OR ALIGN WITH VISION PANEL. VISION WINDOW AS REQUIRED - REQUIRED SIGNAGE INSTALLED ON NEAREST ADJACENT WALL. BOEING FURNISHED CONTRACTOR INSTALLED. WHERE DOOR IS RECESSED SIGN MAY BE LOCATED ON ACCESSIBLE PATH. 18" MIN. CLEAR FLOOR SPACE ON PULL SIDE, 12" MIN. CLEAR FLOOR SPACE ON PUSH SIDE SCALE: N.T.S. 11 A350 A500 SLACK WIRES EA. CORNER 12 GA. HANGER WIRES CROSS TEE 3" MAXIMUM — FROM FIXTURE HEAVY DUTY MAIN RUNNER LIGHT FIXTURE SUPPORT DETAIL SCALE N.T.S. BOTTOM TRACK CONSTRUCTION PER WALL TYPE SCHEDULE CONNECTION SEE DETAIL 1/A501 O FLOORING AND BASE PER FINISH SCHEDULE 3OTTOV OF PATTITIO\ DETAIL SCALE 1 1/2" = 1 —0" A500 8 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 1A45,9 LA500 RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hIll-engineers.eom! Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.09.17 Q�BOE/NG 1;� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. LabreccLue CHECKED B. Leslie APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 SUBTITLE MISC. SECTIONS AND DETAILS CURRENT REVISION 33658 SYMBOL DATE 11.09.17 APPROVED TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A500 JOB NO. DWG NO. COMP NO. 33658 09-08—A500 10:59:12 PM 0 C CD COIX U U #1/4x1" TITEN CONCRETE SCREWS BY SIMPSON OR PRE—APPROVED EQUIVALENT AT 16" O.C. INTO CONCRETE RAISED FLOOR SYSTEM PANEL 3OTTOV CF PATTITIO\ STUD WALL ABOVE AS OCCURS RAISED FLOOR SYSTEM PER GDN ANCHOR EACH PEDESTAL TO EXISTING CONCRETE SLAB WITH (2) 3/8" DIAMETER KWIK BOLT 17 ANCHORS BY HILTI OR PRE—APPROVED EQUIVALENT — EMBED 2" (2 3/8" NOMINAL) MINIMUM WALL SECTIO\ SCALE N.T.S. A 1A450, A5211501 INTERIOR HEADER MAX. WIDTH OF OPENING HEADER SIZE SCREWS EACH SIDE OF HEADER SCREWS INTO JAMB STUD COMMENTS O'-0" TO 4'-0" (2)600S162-43 (4) #12 SCREWS (8) #12 SCREWS REMARKS 4'-1" TO 8'-0" (2)1000S162-54 (7) #12 SCREWS (14) #12 SCREWS 18 COLD FC' v E� HEADED SCHEDULE SCALE: N.T.S. REVISION BY APPROVED DATE SYM 4 1A450 [oi STEEL STUD #10 x 3/4" SCREWS AT 12" O.C. AT DOUBLE STUDS — STAGGER DOUBLE STUD AT JAMBS AND WHERE NOTED STUD BLOCKING 0 UNPUNCHED STEEL STUD TRACK — MATCH GAUGE OF STUDS #10 x 3/4" SCREWS ATTACH EDGE STUDS TOGETHER WITH #10 SCREWS AT 12" O.C. #1/4x1" TITEN CONCRETE SCREWS BY SIMPSON OR PRE—APPROVED EQUIVALENT O.C. INTO CONCRETE RAISED FLOOR SYSTEM PANELS — CENTER WALL ON FLOOR TILES PROVIDE (2) ANCHORS MINIMUM PER WALL SECTION, PLACE MIN. (1) ANCHOR WITHIN 6" OF ALL OPENING EDGES TYPICAL STEEL STUD WALL DETAIL 1 SCALE: N.T.S. A500IA501 MEMBERS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES, U.N.O. USE TYPE DEPTH (IN) FLANGE (IN) GAGE FY (KSI) SECTION GROSS Sxx (IN3) GROSS lxx (IN4) REMARKS 3 5/8" STUDS S 3 5/8 1 5/8 18 33 362S162-43 0.392 0.710 INTERIOR 3 5/8" TRACKS T 3 5/8 1 1/4 18 33 362T125-43 0.302 0.571 INTERIOR 6" STUDS S 6" 1 5/8" 18 33 600S162-43 0.598 1.793 INTERIOR 6" TRACKS T 6" 1 1/4" 18 33 600T125-43 0.604 1.861 INTERIOR COLD FCVED vlEV3E. SCHEDULE 5 SCALE: N.T.S. REVISION BY APPROVED DATE LOBBY RENOVATION 33658 SITTS BKL 11.08.17 PERMIT RESUBMITTAL 33658 SITTS BKL 11.09.17 1A450 A501 STEEL JOISTS PER PLAN STEEL JOISTS PER PLAN L4x4x1/4 ANGLE —EXTEND AND ATTACH TO TWO JOISTS MIN. WITH (2) #12 SCREWS AT EACH JOIST—TYP. 1 L4x4x1/4x12" ANGLE ATTACH TO JOISTS WITH (4) #12 SCREWS MINIMUM 362S162-43 BRACE AT 8'-0" O.C. — ALTERNATE DIRECTION CLIP FLANGE TO FORM SHOE AND ATTACH TO STUD WITH (3) #10 TEK SCREWS PATTIO\ WALL 3QACI\G DETAIL -CEILING PER ARCHITECTURAL 2 Q� BOE/NG SCALE: N.T.S. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN S. McCarthy CHECKED B. Labrecque ENGINEER B. Labrecque CHECKED B. Leslie APPROVED APPROVED DATE 08.22.17 08.22.17 08.22.17 08.22.17 A500 A501 CONNECT TRACKS TO EACH MEMBER OF BUILT—UP HEADER WITH #8 SCREWS AT 12" O.C. TRACK TOP AND BOTTOM OF BUILT—UP HEADER TO MATCH GAGE OF HEADER HEAD HEADER BUILT UP OF TWO STUDS PER SCHEDULE ADDITIONAL STUDS AS NOTED ON PLAN OR ELEVATION CONT. TRACK ABOVE HEADER TRACK CONNECTOR TO MATCH GAGE OF BUILT—UP HEADER — 3" SHORTER THAN DEPTH OF HEADER SCREWS PER SCHEDULE 1/16 C1/2-12 DOUBLE JAMB STUD, TYP. U.N.O. STEEL STUD WALL DETAIL 3 SCALE: N.T.S. SUBTITLE REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 2017 City of Tukwila BUILDING DIVISION REVISION 1 : CORRECTIONS PERMIT RESUBMITTAL NOVEMBER 9, 2017 MISC. SECTIONS AND DETAILS 1A450 A501 RECEIVED CITY OF T(JKWILA NOV 0 9 2017 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET I PHONE: (253) 474.9449 I FAX: (253) 474-9449 http:Uwww.sItts-hill-englneers.coml TACOMA, WA. 98409 Project No.: 18001 Project Mgr.: BKL Proj. Engineer: BRL Proj. Drafter: SLM CURRENT REVISION 33658 SYMBOL DATE 11.09.17 TITLE ARCHITECTURAL LOBBY RENOVATION BUILDING 09-08 B.5—D/17.5-19 DEV. CENTER, WA SHEET A501 JOB NO. 33658 COMP NO. DWG NO. 09-08—A501 10:59:12 PM 0 c co W i 0 0 I 0 0 0 I Cf) 0 N (Id to N SYM (TYP) 1211 0 1 0) X RC1D15/1aR1,R2 / a 12"C, 5 #18 RC1D15/R1,R2 x (TYP) 0 N N 0. . �n = 1.0 0 U RC1C15/13aR13,R14 FIXTURE SCHEDULE: TYPE DESCRIPTION LAMPS MOUNTING SYMBOL FINELITE 2X4 # HPR-LED-A-2X4- DSO -S -835 -277V -SC LED 27W 3500K RECESSED A 0 PRESCOLITE # LC6MLDM1- 6LCML30L35KL8W11 LED 41.5W 3500K RECESSED B 41.5 Ca EN E ) RC1 D15/R5,R CHD mom! —*Ea E 4RC 1 C 15 IYI IYI 11 RC1t15/7a/7aR,,R8 RC1C15/5c/5cR5,R6 E RC1 D15 5c 5cR5,`k6 tw�•i •' �pS.i 1D15 ---3b/3bR SEE SHT. E520 FOR LIGHTING - THIS AREA TI I PI RECUT. C; CONT. ON SHT. E520 '411 EN 1/2"C, 5 #18 RC1 C15/R1,R2 • 10 I �.��� o o ® o amu-*==.... �. ���II,! WNJIMMillaI;S�IN�• .. _ _ - -_• ==.16-211111triiiiiitriMPRIEFADIM mit INMERIP!imizionall1111L11 11111,111=111 �M� - i- i� 1 .. •11\E�'�■ ENi k �a1®III INDELDA ••p••u•iu 0i•iIuum Nom= ® RC1 p159R3,R4 (19 PLS) E SEE LIGHTI E520 FOR - THIS A 3b 1D16/6 TRACK LIG G w w w onm ,w.,w„■w■Y"w'I �,� Y Y Id111■■11dUU U■II III �//1����1�191L71r7/I►iC�►IL7����1��1 ik frI�T� I .1 2-6 ii►_ RC1C15/R17 3/4"C, (2)#12, #12G XD9-1/23c (TYP) (TYP) PROGRAM BOUNDARY (NP) (MP) 10 > CONTINUED ON SHEET E8 RC1C15/R13, R14 1/2"C. 5#18 TYP) REVISION BY APPROVED DATE SYM REVISION PARTIAL FRST FL00� BY APPROVED DATE PLA\ A RECORD DRAWING JMK MJB 10/1/90 F ELEVATORS 535174-00 TEB VAVREK B INSTALL TRACK LIGHTS D5730196 HOWARD N.MEHTA 8/22/95 G 9-08 ENTRY 33658 CASNE CEC 10/14/03 11.09.17 C 9-08 LOWER STAIRWELL LIGHTS 700890-00 VAVREK MOORE 4/6/00 D LOBBY TRACK LIGHTING 700791-00 VAVREK MOORE 4/10/00 PLANNING OFFICE MOD 701620-00 VAVREK MOORE 6/12/00 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN R.HAMMETT DATE CHECKED W.KUHLMAN SUBTITLE LEGE\D QM INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000-A INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000-A INSTALLED WITH TWO LINE VOLTAGE SWITCHES MC INFRARED MOTION SENSOR -CEILING MTD. U.E.C. MODEL AICS 2$M TYPICAL POWER HOMERUN CALLOUT EXAMPLE: RC2D15/9b/9bR9,R10 * RC2D15 INDICATES LIGHTING CONTROL PANEL * /9b INDICATES A NON -RELAY CONTROLLED CIRCUIT * /9bR9,R10 INDICATES CONTROL FROM RELAYS R9 & R10 VIA CIRCUIT 9b #12 CONDUCTORS IN 1/2"C (UNLESS NOTED OTHERWISE) TYPICAL LOW VOLTAGE HOMERUN CALLOUT EXAMPLE: RC2D 15/R9,R10 * RC2D15 INDICATES LIGHTING CONTROL PANEL * /R9,R10 INDICATES INPUTS TO RELAYS R9 & R10 1/2"C, 5/C #18 (UNLESS NOTED OTHERWISE) REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 9 2017 PERMIT CENTER GE\E�AL ALL CONDUIT 1/2E.M.T. UNLESS 1. OTES OTHERWISE NOTED. 2. ALL WIRE #12 AWG THWN/THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS IS OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: 208/120V "A" PHASE BLACK (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL WHITE EQUIPMENT GROUND GREEN 480/277V BROWN RED ORANGE BLUE YELLOW GRAY GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS ARE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. 6. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 7. REFER TO SHEET E313 FOR LIGHTING FIXTURE SCHEDULE. 8. REFER TO SHEET E310 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAMS. 9. REFER TO SHEET E311A FOR LOW VOLTAGE LIGHTING CONTROL SCHEDULE AND SWITCH MOUNTING CONFIGURATION. 110 > REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A14 FOR IDENTIFICATION OF PROGRAM AREAS. 11. TYPE "Al " AND "A2" FIXTURES ARE PROVIDED IN PAIRS IN "MASTER/SLAVE" BALASTING CONFIGURATION. THREE 2 -LAMP BALLASTS CONTROL ALL 6 LAMPS OF THE TWO FIXTURES. ALL WIRING BETWEEN "MASTER" AND "SLAVE" FIXTURE SET IS PROVIDED BY MANUFACTURER IN FLEXIBLE METAL CONDUIT. ISSUE FOR PERMIT NOVEMBER 09, 2017 LIGHTING PLAN CO s -RUCTION \OTES PROVIDE AND INSTALL FINELITE 2X4 LED LIGHT FIXTURE PART #HPR-LED-A-2X4-DCO-S-835-277V-SC OR APPPROVED ALTERNATIVE IN DROPPED CEILING. PROVIDE CONDUIT, CONDUCTORS AND ANCILLARY HARDWARE BACK TO SOURCE PANEL PROVIDE LOW VOLTAGE MOMENTARY SWITCH AND WIRE BACK TO LIGHTING CONTROL PANEL PROVIDE 6" LED DOWNLIGHT FIXTURE IN DROPPED CEILING PRESCOLITE PART # LC6MLDM1-6LCML30L35KL9WH OR APPROVED ALTERNATIVE. PROVIDE UL 924 EMERGENCY LIGHTING CONTROL RELAY. CONTRACTOR TO WIRE RELAY TO EMERGENCY AND NORMAL POWER. PROVIDE AND INSTALL EDGE LIT EXIT SIGN PROVIDE LOCAL ARE LINE VOLTAGE SWITCH. CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE COM JOB NO. 171-094 CURRENT REVISION 33658 SYMBOL DATE 11.09.17 ENGINEER R.HAMMETT CHECKED J.KOKOCZKA APPROVED M.BENTSON APPROVED D.SEPTELKA 10/1/90 TITLE ELECTRICAL MASTER 9-08 ENTRY BUILDING 9-08.1 COL. A -F/14-20 DEV. CENTER, WA SHEET 1E12 JOB NO. 535174-00 COMP NO. DWG NO. 9-08.1-1E12