Loading...
HomeMy WebLinkAboutPermit D17-0296 - BOEING #14-01 - A/V SUPPORT FOR VOCATION LEARNING AREABOEING #14-01 8701 E MARGINAL WAY S BLDG 14-01 D17-0296 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT 0007400033 Permit Number: D17-0296 8701 E MARGINAL WAY S BLDG 14-01 Issue Date: Permit Expires On: Project Name: BOEING #14-01 11/27/2017 5/26/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH Phone: (253) 350-5522 PO BOX 3707 MC 46-88 , SEATTLE, WA, 98124 BOEING COMPANY, THE Phone: (312) 544-2535 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML Expiration Date: 1/18/2019 BOEING COMPANY PO BOX 3707 , SEATTLE, WA, 98124 DESCRIPTION OF WORK: RECONFIGURATION OF CONFERENCE ROOMT 0 ACCOMMODATE NEW A/V SUPPORT FOR ADJACENT VOCATIONAL LEARNING AREA. ALL WORK IS NON-STRUCTURAL. A/ SUPPORT UNDER SEPARATE PERMIT. Project Valuation: $107,845.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $2,825.83 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 1 1)-7—�� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditi ns attached to this permit. Signature: Print Name: l n v !`' rh ('44 - Date: J This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: ***BUILDING PERMIT CONDITIONS*** 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 15: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 23: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 21: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 22: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 24: Maintain fire extinguisher coverage throughout. 25: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 26: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 32: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 34: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 1400 FIRE FINAL 0409 FRAMING 1500 PLANNING FINAL 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. P1 Blanket Permit No. PA 11--0001 Date Application Accepted: `O • 21 • f1 6.1.142 Date Application Expires: (For office use only) BLANKET PERMIT TENANT IMPROVEMENT APPLICATION **Please Print** FEES: For office use only Existing (square feet) Construction Area (square feet) Amount Receipt No. Date Building Permit Fee $ 1(/ 1 • 1A ! ! / 05 iii / Plan Review Fee $ l' j/� • 14 E305 2"d Floor17/91620 State Building Surcharge $ 4.50 Total $ SITE INFORMATION: Valuation of Construction: 101. v44 Site Address: 8701 BAST MAR6 //UAL Lail S. Tenant Name: THE $0s1M6 (W 1PAN y King Co Assessor's Tax No.: Suite Number: Floor: Description of work: REcLN F16VR,4.7701) comr-FAENcaRcom 7? 1 ncsmo - N W ,4fv SUpkr PD,R ,4WACj1T VOCATJON, I -L L ifRAJ//J6 74RF4. ALL wogK is MOM - 57 CrV 4 50Piter o)Jjj L &'PEt pol'r Per the International Building Code — 2015 Edition 1. Will there be any structural work? Yes ...NO If yes, please describe: 2. Will there be new rack storage? Yes .X..NO If yes, a separate permit and plan submittal will be required. 3. Will there be a change in use? Yes ..%i.No If yes, please explain: 4. Existing fire protection: .X Sprinklers X Automatic Fire Alarm .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes .x.No If yes, please explain: H:\Applications\Forms-Applications On Line\2016 Applications\Blanket Permit 77 Application - 7-2016.docx Revised: July 2016 bh Page 1 of 3 Existing (square feet) Construction Area (square feet) Type of Construction per IBC Type of Occupancy per IBC Building Use 1' Floor 514 bal ! / 05 iii / 1P1/4.1 E305 2"d Floor17/91620 3rd Floor Floors /thru_ 0•7 ,41/ is/ (i IV 1. Will there be any structural work? Yes ...NO If yes, please describe: 2. Will there be new rack storage? Yes .X..NO If yes, a separate permit and plan submittal will be required. 3. Will there be a change in use? Yes ..%i.No If yes, please explain: 4. Existing fire protection: .X Sprinklers X Automatic Fire Alarm .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes .x.No If yes, please explain: H:\Applications\Forms-Applications On Line\2016 Applications\Blanket Permit 77 Application - 7-2016.docx Revised: July 2016 bh Page 1 of 3 PROPERTY OWNER //J /1� Name:/o y fA o / , riteRao. W, Address: p O , /h)' tit y6 ilk 46 130)(310.7. /� City/State/Zip f('1/1� (G�`i,' wk g8r21f.. mg. CONTACT PERSON — person receiving all project communication Name:, /Q0/ Li' Hovel( /lW Company Name:�i jo/&NPAW Y & i v Address: P.0 h( 3 16 4436 City/State/Zip: %f+nte &JA f8/ZLr- - 6 ! Phon&9) 3N.✓ ZZ Fax: Ema\ john. S• fivirdOckokeinitavvi ARCHITECT OF RECORD Name: .4-R fel Cp4A sTz, r Name: Roux Rouif ARea 5 /lVj Address: lo,s S. ,* i,4- sr) sx4323 City/State/Zip:�r-- itr tem tvo rl j60.4 Phone: q,.,4 . 62�TT4222Fax: 26:,. �22.ro % Email:ew(( a rol/c daarc4rTeds. CDvn GENERAL CONTRACTOR INFORMATION Company Name: rig 7 e/J6,�►e+ f ' Address: r,o , a�7/' t /A"l/# ex-a3 L viA tool- I Phone(Z $) ' 55M Contr Reg No.: EpellyC, * Z1Llg1Date: 091,7 11,, ►►� Tukwila Business License No.: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.0(955)),w, n,��pp `' �/ Name: m e fW& U�li AtY 7 Address:lj,IS� ,x 3737_',� a3 46.13g� /M/e. City/State/Zip:'C r Z 1(vk -1exz `f - 045 I hereby certify that I have read and examined this application and know the same to be true and correct, and I am authorized under Blanket Permit •ree -nt No. SPA 11100Y to apply for and obtain this permit. Signature: 41/11( --"Ne WW1 `-`"-lla`s`/ DateO 61/6%1 Zb0 Print Name: / '11 Organization: Wig& vt 1& ( 1Q� Ic Day Telephone: (s) 350- 5Zt Mailing Address:?O' SO` 31 I6 Mos -rite VSA i - "-"1- City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Blanket Permit TI Application - 7-2016.docx Revised: July 2016 bh Page 2 of 3 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.zov BLANKET PERMIT AGREEMENT — Architects Statement. Plan Review No.: 'al QD BVI ef' Blanket Permit Agreement No.: PAt7 -0009 /q--01 P- 8 PRopucr /N7t'6RA71okt CEN7 g70/ .ST MARWM,4L &,4y s., 7vkaill A- WA AVM Project Name: Site Address: Is any part of the work proposed under this application include ❑ Yes No structural work or affect structural components of the building? If yes, has the structural work been authorized by the Tukwila ❑ Yes ❑ No Building Official to be included in this application? Does the proposed work comply with the requirements of xi'Yes ❑ No the International Building Code (2015 Edition) Chapter 10, Means of Egress? If no, please explain: Will any special inspections be required per Chapter 17 ❑ Yes in the International Building Code (2015 Edition)? No If yes, list specific inspections: As a result of this proposal, does the parking meet the requirements of the Tukwila Zoning Code? X Yes ❑ No If no, please explain deficiency: ARCHITECT/ENGINEER Signature • ( D V Print Name: ER% e. cp...ANsrem Organization: ROLUVA ARCFT (%ECTS Mailing Address: /0 S. Al Cin ARCHITECT/ENGINEER STAMP AND SIGNATURE H:\Applications\Forms-Applications On Line\2016 Applications \Blanket Permit Architect Statement - 7-2016.docs Created: 12-2008 Revised: 7-2016 Phone: 2 &024. 2V 2• State Zip Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $2,825.83 D17-0296 Address: 8701 E MARGINAL WAY 5 BLDG 14-01 Apn: 0007400033 $2,825.83 Credit Card Fee $82.31 Credit Card Fee R000.369.908.00.00 0.00 $82.31 DEVELOPMENT $2,662.96 PERMIT FEE R000.322.100.00.00 0.00 $1,611.19 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,047.27 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $80.56 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R12695 0.00 $80.56 $2,825.83 Date Paid: Tuesday, October 31, 2017 Paid By: JOHN S MURDOCH Pay Method: CREDIT CARD 066247 Printed: Tuesday, October 31, 2017 1:35 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO, Dr)PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: SOEt ly- 0! Type of Inspection: JLit1,-NA `f 'A -L-. Address: yam` Old f MAY --4 t"- Date Ca ed: Special Instructions: Pl411:,/ ,/ Date Wanted: ZI a.m. m. Requester: 4 Phone No: 26a1-• 970 6512- LCApproved per applicable codes. Corrections required prior to approval. COMMENTS QJiL14 ��4L 7101 itzAt Pf Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, f(e must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 117-0296 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projec . 11) CeA. na p- -c-/d T e of Inssp tion: I _ `- -- a l t �!]V> t, Address:/ 1M(J Date Called: Special Instructions: Date Wanted:9 a.�rr, 3,-,1,d7,4 Q J Requester: 6 IrCt/C14"9111 ( Phone No: Zo(- 92o- 69z12__ ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 16.!,. id ,FwvAL /1 Bu►a p/irvaL 5 re/d(D/fili1)4(_ /4-ipfrevez, Inspector: 3tea;2_ Date: — 2e— /‘ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 U I'1-029(0 Pr."oms' T.5Ce of Inspectio a-1'1 1 Address: i ./ [ , ', ; E V(/ e Date CaIIrd: T- Special Instruction / 4 Li _ / 8 Date Wanted: F-pcc' CJI 7�,r a.m. p.m. Requester: Phone No: 9 pproved per applicable codes. Corrections required prior to approval. COMMENTS: sP(v®r0 G€iyNc Inspector: Date: -a-7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, l� 0)916 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project) ` oe 4 lit --01 Type of Inspection: trA w► Iry Address: r 0)01 E Mal; ,,,,t Cil Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: r G re Phone No: ,, nn( Ob -61.)4 ^ -1W91R Approved per applicable codes. Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 8:30 Ari INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 D—Od-qo oject; 4 ��`�I Type of 1 pectiori: 114+M1TS Address: 8701E Kwypia., ti.2&q S. Date Called: u Special Instruction /Lf_ l ,`/r�, L Date Wanted: a.m: (O `!�-2D p.m. Requester:GI Phone No: - — z06- '?-.240 -Oa. ElApproved per applicable codes. �QCorrections required prior to approval. COMMENTS: rig. co ley0 /1 A-)e)ed ee.ten4;-1- ,44,, kt JO- afra pe-Vfleff+. Inspector. 12jj C4 Date ` REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D1-7-046 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:. is Type of nspection:n� Address: 37D/ E, frit it L fit (g ‘..,,,,cr Galled: Special Instructions: /� 1 Date Wanted: (f, ` 2-1 `_ 7 --CD( a.m. p.m. Re9u fl rfq �' C� Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date. REINSPECTION FEE REQUIRED. Prior to next inspectio . ee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule rel ection. 2/7/2019 City of Tukwila Department of Community Development MARTIN PROBST PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. D17-0296 BOEING #14-01 8701 E MARGINAL WAY S BLDG 14-01 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/19/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/19/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Jazzel Salzar Permit Technician File No: D17-0296 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director May 21, 2018 Martin R Probst PO Box 3707: Mail Stop 46-208 Seattle, WA 98124 RE: Request for Extension #1 Permit Number D17-0296 Dear Mr. Probst, This letter is in response to your written request for an extension to Permit D 17-0296. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 26, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, JsiNachelle Ripley Permit Technician File: Permit No. D17-0296 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 'rhe Boeing Company l aciliiic, ,Y reset Manal;cmcnt Supply (Thain & Opeititiuu ("ode C omphanee L Permitting Thursday, May 17, 2018 GG-GG-PCTA-180308 City of Tukwila Dept. of Community Development Attn: Jerry Hight 6300 Southcenter Blvd., Suite 100 Tukwila, WA. 98188-2544 Subject: Dear Mr. Hight; Permit Extension Request Project#. D17-0296 Project Description: 14-01 Building P8 Product Integration Center The Boeing Company Per our records we show that Permit# D17-0296 expires on 5/26/2018. This permit is for Boeing's P8 Product Integration Center Reconfiguration project. Due to the fact that Finance was slow with the appropriation of funding we had to delay this project. Per Section 105 of the International Building Code "[A] 105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The building official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated." Would you please grant The Boeing Company an extension of 180 days for this project? You have my appreciation in advance of your consideration on this matter. Best Regards, Martin R. Probst Code Compliance & Permitting The Boeing Company PO Box 3707: Mail Stop 46-208 Seattle, WA 98124 206-852-4985 , Author @ RECEIVED CITY OF TUKWILA MAY 17 2018 PERMIT CENTER Request for Extension:: # 1 Current Expiration Date: Extension Request: Approved for _OTC) days 1 Denied (provide explanation) 1 Signature/Initials 4/2/2018 City of Tukwila Department of Community Development MARTIN PROBST PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. D17-0296 BOEING #14-01 8701 E MARGINAL WAY S BLDG 14-01 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/26/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/26/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle Ripley Permit Technician File No: D17-0296 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670, • Fax 206-431-3665 ._ PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0296 DATE: 10/31/17 PROJECT NAME: BOEING #14-01 SITE ADDRESS: 8701 EAST MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1 4wc, LV-3-si Building Division Public Works PTV\ ANO 11 Fire Prevention Structural 4 1I Planning Division ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/02/17 Structural Review Required REVIEWERc6 INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/30/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERc6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: I2/I8/20I3 BOEING COMPANY, THE Home Espanol Contact Search L&I Page 1 of 9 A -Z Index Help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries BOEING COMPANY, THE Owner or tradesperson LOHR, MICHAEL Principals LOHR, MICHAEL, SECRETARY MCNERNEY, W (JAMES), PRESIDENT (End: 01/13/2017) WOLTER, CHRISTOPHER, TREASURER (End: 01/16/2015) READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) WA UBI No. 178 005 030 100 N RIVERSIDE M/C 5003-4027 CHICAGO, IL 60606-1596 312-544-2535 Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. BOEINC*294ML Effective — expiration 07/13/1971— 01/18/2019 Active. Meets current requirements. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 11/27/2017 BOEING COMPANY, THE Bond ............... FEDERAL INS CO Bond account no. 81312466 $12,000.00 Received by L&I Effective date 01/14/2002 01/01/2002 Expiration date Until Canceled Insurance ................ ............ Ace American Insurance Company Policy no. HDOG27870442 $10,000,000.00 Received by L&I Effective date 10/06/2017 10/01/2017 Expiration date 10/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 700,216-00 Doing business as BOEING COMPANY THE Estimated workers reported N/A L&I account contact (360)902-4817 Track this contractor {^, Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/31/2017 Inspection no. 317945013 Location 3003 W Casino Rd Everett, WA 98203 No violations Page 2 of 9 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 11/27/2017 VICINITY MAP FROM DOWNTOWN SEATTLE 0 14-01 900 rrl rn 99 EXIT 158 EXIT 157 EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE -TACOMA AIRPORT 599 TUKWILA DEVELOPME\TAL CE\TE FROM KENT & AUBURN 900 NO SCALE BUILDING 14-001 P-8 PRODUCT INTEGRATION CENTER 8701 EAST MARGINAL WAY SOUTH TUKWILA, WA 98108 CODE SUMMARY TYPE OF APPLICATION: ❑ NEW ❑ ALTERATION ❑ ADDITION % TENANT IMPROVEMENT PROJECT DESCRIPTION: PROJECT INCLUDES CONSTRUCTION OF NEW WALL TO DIVIDE FORMER CONFERENCE ROOM INTO TWO SPACES (SMALL OFFICE AND EQUIPMENT ROOM FOR NV PRESENTATION). CONVERSION OF OPEN OFFICE TO EDUCATIONAL AREA. MINOR LIGHTING, POWER AND HVAC WORK IN SUPPORT OF THE NEW CONFIGURATION. THIS PROJECT HAS NO LOAD-BEARING WORK INVOLVED. CODES: 2015 INTERNATIONAL BUILDING CODE & WAC 51-50 2015 INTERNATIONAL MECHANICAL CODE & WAC 51-52 2015 INTERNATIONAL FIRE CODE & WAC 51-54 CURRENT WASHINGTON STATE ENERGY CODE WAC 51-11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER: THE BOEING CO. BOEINC* 294ML (01.18.2019) BOEING PROJECT ENGINEER: GEOFF MILLER 253.657.0864 BOEING CONTACT: JOHN MURDOCH PHONE. 253.740.0214 FAX NUMBER. E-MAIL. john.s.murdoch@boeinq.com OCCUPANCY GROUP. GROUP BI BUSINESS CONSTRUCTION TYPE• TYPE II -B ZONING: ALLOWABLE AREA INCREASE- SPRINKLERED & 60' SET -BACK (NO CHANGES) OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA: (ACTUAL) NO CHANGE (TABLE 10-A) OFFICES OCC BLDG GROSS 97,903 SF SQ FT STORAGE OCC TUNNEL SQ FT LABORATORY OCC FIRST FLOOR 54,821 SF SQ FT CANOPY OCC 1ST FLR MEZZ SQ FT OTHER OCC 2ND FLOOR 43,080 SF SQ FT 2ND FLOOR MEZZ SQ FT PROJECT AREA 1ST FLR. 1,603 SF SQ FT BUILDING HEIGHT: (ACTUAL) 44 FT STORIES: 2 MEZZANINE ? ❑(YES) (NO) FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 ? SEPARATION SQ FT (YES) ❑(NO) EXTERIOR WALL (NON-BEARING) EXTTERIOR WALL (BEARING) INTERIOR WALL (NON-BEARING) INTERIOR WALL (BEARING) DEMOUNTABLE PARTITION STRUCTURAL FRAME FLOOR/CEILINGS ROOF CONSTRUCTION HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING NON -COMB NON -COMB NON -COMB NON -COMB NON -COMB SEISMIC DESIGN: ZONE fl D/) DESIGN LOADS: (CHAPTER 16) ROOF: LIVE (SNOW) (PSF) FLOOR: OFFICE (PSF) MECH/STOR (PSF) STAIRS (PSF) CONCENTRATED. WIND: EXPOSURE 80 MPH, EXPOSURE C DRAWING INDEX ARCHITECTURAL DRAWING NUMBER REV DRAWING TITLE 14-001—GO — COVER SHEET 14-001-1 A11 AR F PARTIAL FIRST FLOOR REMOVAL PLAN 14-001-1A11 A F PARTIAL FIRST FLOOR PLAN 14-001-1L11 A A PARTIAL FIRST FLOOR LAYOUT PLAN 14-001-1A281A C PARTIAL FIRST FLOOR REFLECTED CEILING PLAN 14-001—A375 — INTERIOR ELEVATIONS 14-001—A514 — MISCELLANEOUS DETAILS MECHANICAL DRAWING NUMBER REV DRAWING TITLE 14-001—M 1 B — HVAC LEGEND AND ABBREVIATIONS 14-001—M 1 C — INSTRUMENTATION LEGEND AND ABBREVIATIONS 14-001—M2A B EQUIPMENT SCHEDULES 14-001-1 M261AR E FIRE PROTECTION PLAN — REMOVAL 14-001-1 M 11 A A DUCTWORK PLAN ELECTRICAL DRAWING NUMBER REV DRAWING TITLE 14-001—E1 A ELECTRICAL LEGEND 14-001—E4ST2R E ONE—LINE DIAGRAM, UNIT SUBSTATION 12 — REMOVAL 14-001-1 E11AR C LIGHTING PARTIAL PLAN — REMOVAL 14-001-1 E61 AR J 208Y/120 VOLT POWER — REMOVAL 14-001—E505R A DETAILS — LIGHTING CONTROL DIAGRAM — REMOVAL 14-001—E4ST2 E ONE—LINE DIAGRAM, UNIT SUBSTATION 12 14-001-1E11A C LIGHTING PARTIAL PLAN 14-001-1 E61 A J 208Y/120 VOLT POWER 14-001-1 E411A — COMMUNICATIONS — 1ST FLOOR PARTIAL PLAN 14-001—E501 D LIGHTING FIXTURE SCHEDULE AND DETAILS 14-001—E505 A DETAILS — LIGHTING CONTROL DIAGRAM 14-001—E597 — DETAILS 14-001—E598 — DETAILS — LIGHTING & RECEPTACLE CONTROL DIAG. AUDIO / VISUAL 14-001—PS001 A AV ROOM SCHEDULE 14-001—PS100 A AV FLOOR PLAN 14-001—PS101 A AV LAYOUT PLAN 14-001—PS102 A AV REFLECTED CEILING PLAN SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE TANKER BOOM ASSEMBLY - RECORD DRAWING 16735 HGI SEL 07.12.13 A P-9 PRODUCT INTEGRATION CENTER W5005152 EC/ROLLUDA 09.26.17 AV® 6604 STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R. PINLAC DATE 08.22.12 APPROVED BY DEPT. DATE CHECKED P. TSCHERNEGA ENGINEER R. GHIGLIANO CHECKED L COSGROVE 08.22.12 08.22.12 SUBTITLE FILE COPY Permit No. P1O19\Q Plan review epprc val is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinanc3. Receipt of approved Fold Copy and con9itior cknowledgad: By. r/1//,! Date: I / - 7- i --11 City of Tukwila BUILDING DIVISION CODES AND PERMITS PROJECT TITLE: 14-01 P-8 PRODUCT INTEGRATION CENTER JOB NUMBER: W5005152 QUANTITY SUBMITTED: O 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT 0 4 SETS: TENANT IMPROVEMENT (NON-STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS O 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: El BUILDING 0 GRADING ❑ PLUMBING ❑ LANDSCAPE O MECHANICAL 0 DEMOLITION ❑ STRUCTURAL ❑ - * TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE -APPROACHES COMPLIANCE OPTION ❑ PRESCRIPTIVE ❑ LPA 0 ANALYSIS 13 N/A SPECIAL INSPECTIONS REQUIRED: O WELD ❑ CONCRETE O REBAR 0 ANCHOR BOLTS O STRUCTURAL BOLTING 0 STRUCTURAL OBSERVATION ❑ OTHER CALCULATIONS TYPE• ATTACHED (YES) ❑ ELECTRICAL O FIRE PROTECTION O CANTILEVER RACKS ❑- (NO) REVISIONS No changes sha!1 bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees I SEPARATE PL RRM1T REQUIRED FCR: LTJ mechanical OPPlumbing lectncal 0/Gas Piping City of Tukwila BUILDING f'IViSION CITY OF TUKWILA USE BLANKET PERMIT NO. BPAI______7:219 ISSUE FOR CONSTRUCTION 09.26.17 COVER SHEET REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 K.\ City of Tukwila BUILDING DIVISION 011-01.4 l4 CURRENT REVISION W5005152 SYMBOL RECEIVED Cls 's' 3E T UKWIL.A i € a PERMIT CENTER DATE 09.26.17 08.22.12 APPROVED S. LUSK 08.22.12 APPROVED TITLE GENERAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-001 THOMPSON, WA SHEET GO JOB NO. W5005152 COMP NO. DWG NO. 14-001—GO 174 FIRE RISER CHASE 13B12 (12812 20'-0" 20'-0" 1 3.2 20'-0" f3/ 20'– IP 20'-0" 14.E PP 8' – „ 0 �r- Q U_ N 0 A11A A500 2'-3" BREAK R00 18B12 6" WALL INFILL 0 TYP L 1A11A A201 11" 6 C STORE 19813 B13 CORRIDOR N � 1035 OWER 11B13 (18B13) b DF 61 GWB ABOVE CMU TO METAL DECK SIM OPP HAN11 A A201 MATCH LINE – SEE SHEET 1A14 FIRE HOSE CABINET FEC B13 LL' WITI OMR 12B13 JANITOR 16B13 1A11 ALA201 OPEN OFFICE 13814 20'-0" 20'-0" 15 20'-0" 15.2 20'-0" 15.E 20'-0" WALL INFILL SEE 1/A505 TYPICAL L -J 4B13) VESTIBULE 3B13 1 000 WOMENS 14B13 a n SIMILAR GWB ONE SIDE 16813 u uuU I L 1 1A11A A450 410� tA11A1A500 2'-7' TRANSPORTATION AISLE 1088 FEC PATTIAL FI QST FLOO PLA\ SCALE: 1/8"=1'-0" (13815 1 JANITOR 13815 12B15 b DF (121:315) FIRE HOSE CABINET CONFERENCE ROOM 15615 -TRENCH 1A11A A203 FUR OUT WITH METAL STUDS AND GWB TO ALIGN WITH ADJACENT TYPE AWALL GE\E SAL v T_ REFER TO DRAWING Al FOR TYPICAL MATERIALS AND SYMBOLS LEGENDS. 2. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR DOOR SCHEDULE. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR ROOM FINISH SCHEDULE. 4. REFER TO DRAWING A350 FOR WALL TYPES. 5. REFER TO DRAWING A351 FOR RELITE TYPES. 6. REFER TO DRAWING A110, SECTION A/A110 FOR GENERAL BUILDING SECTION. 7. RECESSED FEC AND FHC SEE DETAILS 10 AND 11 ON SHEET A200. 8. CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. EIVOVAL \ OTES: REMOVE EXISTING CARPET AND R. BASE AT AREA SHOWN HATCHED. APPROX. 145 S.F. REMOVE EXISTING CHAIR RAIL AND TACKBOARD AT WALLS AT AREA SHOWN HATCHED. LEAVE UNHATCHED AREAS INTACT. PATCH AND PREP WALLS AS REQUIRED BY REMOVAL. REMOVE PORTION OF EXISTING WALL FOR NEW A/V EQUIPMENT. COORDINATE FINAL LOCATIONS AND DIMENSIONS WITH A/V CONTRACTOR. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED BY REMOVAL. REMOVAL ISSUE FOR CONSTRUCTION 09.26.17 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION 1 4 «66 0 n I v 1-__7-1 1A10A 1A10B 1A11A 1A118 I� 1Al2 1A13 1A14 1A15 1A16 1A17 1A18 1A19 �J KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE C REVISE OFFICE J#979061-00 PJG 04.15.97 D REMODEL QA OFFICE J#D83P0202 GAVRAS 03.02.98 CAD CONVERSION CADDNW 04.21.98 E MODIFY OFFICE FOR B-NN14 J#993098-00 BOYE 09.23.99 F P-8 PRODUCT INTEGRATION CENTER W5005152 EC/ROLLUDP 09.26.17 6604 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED .''PROVED BY ERICN STATE OF WASHINGTON DEPT. DATE DRAWN D. PLAGENS DATE SUBTITLE J. HILLIER CHECKED G. KRAPE ENCINEER PARITAL FIRST FLOOR REMOVAL PLAN CURRENT REVISION SYMBOL W5005152 F 7 PERUT CENTER R" DATE 09.26.17 T. DRAG00 CHECKED G. CULTUM 7.25.94 APPROVED APPROVED TITLE ARCHITECTURAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. B–C/12.4-16 SHEET IAIIAR JOB NO. W5005152 COMP NO. PLANT 2 DWG NO. 14.01-1A11AR G=\=SAL \OTES: FIRE RISER CHASE 13B12 WALL INFILL 1A11A A201 WALL INFILL SEE 1/A505, TYPI FIRE RISER CHASE REFER TO DRAWING Al FOR TYPICAL MATERIALS AND SYMBOLS LEGENDS. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR DOOR SCHEDULE. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR ROOM FINISH SCHEDULE. 4. REFER TO DRAWING A350 FOR WALL TYPES. 5. REFER TO DRAWING A351 FOR RELITE TYPES. 6. REFER TO DRAWING A110, SECTION A/A110 FOR GENERAL BUILDING SECTION. 7. RECESSED FEC AND FHC SEE DETAILS 10 AND 11 ON SHEET A200. WIT MGR OPEN OFFICE 13814 C STORE 12B13 1A11A A450 BREAK RO0 18B12 19813 CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. CONFERENCE ROOM TIBULE 15B13 WOMENS 15B15 14813 GWB ABOVE CMU TO METAL DECK SIM OPP HA4N11A A201 MENS 15B13 JANITOR 13B15 �-TRENCH JANITOR X:- i6B13 16813 731 1A11A A500 12B15 MATCH LINE — SEE SHEET 1A14 FIRE HOSE CABINET 17B13 SIMILAR GWB ONE SIDE TRANSPORTATION AISLE 12B14 FIRE HOSE CABINET 1A11A A201 1A11A A203 FUR OUT WITH METAL STUDS AND GWB TO ALIGN WITH ADJACENT TYPE AWALL PA TIAL ERST FLON PLA SCALE: 1 /8"=1'-0" IBC TABLE 1004 — OCCUPANT LOAD — PROPOSED ROOM NAME OCC. GROUP AREA (SF) OCC. LOAD FACTOR OCC. LOAD VOCATIONAL LEARNING OFFICE (B) 1,304 SF 100 SF/OCC. 14 PRINTER ROOM OFFICE (B) 143 SF 100 SF/OCC. 2 EQUIPMENT ROOM OFFICE (B) 143 SF 100 SF/OCC. 2 TOTAL OCCUPANT LOAD 18 IBC TABLE 1004 — OCCUPANT LOAD — EXISTING ROOM NAME OCC. GROUP AREA (SF) OCC. LOAD FACTOR OCC. LOAD OPEN OFFICE OFFICE (B) 1,304 SF 100 SF/OCC. 14 CONFERENCE ROOM OFFICE (B) 290 SF 15 SF/OCC. 20 CO\S-RUCTIO\ \OTES (CO\T'D): 1> CONSTRUCT 2'-6" X 3'-0" X 6" THICK CONCRETE PAD FOR NEW MECHANICAL EQUIPMENT. TOP OF SLAB TO BE 2" HIGHER THAN ADJACENT PAVING. PAINT SIDES AND 3" FROM EDGE ON (3) SIDES. FEDERAL STANDARD 5958 'SAFETY YELLOW' #23655 PAINT PEDESTRIAL WALKWAY STRIPE, 3" THICK, WHITE, IN CONFIGURATION SHOWN. SAWCUT, PATCH AND REPAIR, EXISTING FLOOR SLAB AS REQUIRED FOR NEW CONDUIT RUN TO NEW TOUCH TABLE. SEE SHEETS 1E411A AND PS100 IN THIS SET. CO \ STUCTIO\ \OTES PREP CONCRETE SLAB, PROVIDE AND INSTALL NEW VCT FLOORING AND R. BASE AT EQUIPMENT ROOM. TILE: ARMSTRONG EXCELON IMPERIAL, 12" X 12" #51836 'CLASSIC SHELTER WHITE' BASE: BURKE—MERCER 'BLACK—BROWN' 4" COVE PATCH, PREP AND PAINT WALLS FROM FLOOR TO CEILING. GLIDDEN 'CRISP LINEN' A0057, EGGSHELL COORDINATE OPENING SIZE AT WALL FOR NEW A/V EQUIPMENT. PROVIDE SHEET METAL TRIM AROUND NEW OPENING. COLOR TBD. REMOVE EXISTING LATCHSET AT DOOR 11B14. PROVIDE LOCKSET AT EQUIPMENT ROOM SIDE WITH BLANK AT OTHER SIDE. PROVIDE AND INSTALL DOOR SWEEP. LOCKSET: YALE AU5429LN (F113) X US26D SWEEP: PEMKO 4301 CRL X 3'-0" CONSTRUCT NEW WALL FROM FLOOR SLAB TO 9'-6" A.F.F. MODIFY EXISTING CEILING GRID AS REQUIRED. 3 5/8" X18 GA. STEEL STUDS AT 16" O.C. 3" ROXUL AFB INSULATION 5/8" TYPE 'X' GWB EACH SIDE. PREP AND PAINT. SEE FLAGNOTE #2 FOR COLORS. PROVIDE AND INSTALL NEW 3'-0" X 7'-0" SOLID—CORE WOOD DOOR AND HM FRAME AT NEW WALL. HINGES: STANLEY FBB179 X 4.5 X 4.5 X US26D LOCKSET: YALE AU5408LN X US26D SEAL: PEMKO SS8D X 17' SWEEP: 4301 CRL X 3'-0" STAIN DOOR TO MATCH EXISTING. PAINT DOOR FRAME TO MATCH EXISTING. PROVIDE AND INSTALL ACOUSTIC TILES AT WALLS FROM R. BASE TO CEILING ABOVE ON NORTH, WEST AND SOUTH WALLS. SONEX CLASSIC, 24" X 48" X 2" THICK, CHARCOAL COLORTEC, NRC 0.75 PROVIDE AND INSTALL ACOUSTIC TILES AT WALLS AS SHOW ON SHEET A375. SONEX CONTOUR 'BASIX', 24" X 24" LIGHT BLUE, BLACK, WHITE AND LIGHT GREY (SEE A375) AT NEW MECHANICAL PIPING PENETRATIONS, PROVIDE FLASHING/SEALING PER DETAIL A/A514. ISSUE FOR CONSTRUCTION 09.26.17 SYM C REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REVISE OFFICE J#979061-00 D F REMODEL QA OFFICE CAD CONVERSION J#D83P0202 PJG 04.15.97 GAVRAS CADDNW 03.02.98 04.21.98 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN D. PLAGENS CHECKED G. KRAPE DATE SUBTITLE J. HILLIER PARITAL FIRST FLOOR PLAN DATE T. DRAGOO MODIFY OFFICE FOR B-NN14 J#993098-00 P-8 PRODUCT INTEGRATION CENTER BOYE 09.23.99 STATE OF WASHINGTON CHECKED G. CULTUM APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER CURRENT REVISION W5005152 SYMBOL 09.26.17 7.25.94 W5005152 _C/ROLLUDA 09.26.17 APPROVED ARCHITECTURAL MASTER BUILDING 14-01 COL. B—C/12.4-16 JOB NO. W5005152 COMP NO. PLANT 2 DWG NO. c c c r c c z 14.01-1A11A n T 1A11A ` ' v Ty -i 1A11B 1A10A 1A10B 1Al2 1A13 1A14 1A15 1A16 1A17 1A18 1A19 1 ISSUE FOR CONSTRUCTION 09.26.17 SYM C REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REVISE OFFICE J#979061-00 D F REMODEL QA OFFICE CAD CONVERSION J#D83P0202 PJG 04.15.97 GAVRAS CADDNW 03.02.98 04.21.98 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN D. PLAGENS CHECKED G. KRAPE DATE SUBTITLE J. HILLIER PARITAL FIRST FLOOR PLAN DATE T. DRAGOO MODIFY OFFICE FOR B-NN14 J#993098-00 P-8 PRODUCT INTEGRATION CENTER BOYE 09.23.99 STATE OF WASHINGTON CHECKED G. CULTUM APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER CURRENT REVISION W5005152 SYMBOL 09.26.17 7.25.94 W5005152 _C/ROLLUDA 09.26.17 APPROVED ARCHITECTURAL MASTER BUILDING 14-01 COL. B—C/12.4-16 JOB NO. W5005152 COMP NO. PLANT 2 DWG NO. c c c r c c z 14.01-1A11A 144 FIRE RISER CHASE 13B12 13 20'-0" 20'-0" 20'-0" vie 20'-0" 1 /1 Mr - 20' -0' 14� 20'-0" 144 20'-0" 15 20'-0" 20'-0" 20'-0" 4' -5" 8'-7" 2'-3" �b WALL nP�4� 1A11A A201 OP - „ FIRE RISER CHASE INFILL WALL INFILL SEE 1/A505 TYPICAL J CORRIDOR �12B12 OPEN OFFICE 13B14 a N O I w w w J U C STORE 12B13 REAK R00\I 19B13 18B12 1A11A A450 11B1 (13B13 481 3) VESTIBULE 13B13 WOMENS CONFERENCE ROOM (13B15) 15B15 GE\PAL \OTES: 14B13 REM PROJECRON EQUIPMENT 1. REFER TO DRAWING Al FOR TYPICAL MATERIALS AND SYMBOLS LEGENDS. 2. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR DOOR SCHEDULE. 3. REFER TO SPECIFICATION DOCUMENT SECTION 00004 FOR ROOM FINISH SCHEDULE. 4. REFER TO DRAWING A350 FOR WALL TYPES. 5. REFER TO DRAWING A351 FOR RELITE TYPES. 6. REFER TO DRAWING A110, SECTION A/A110 FOR GENERAL BUILDING SECTION. 7. RECESSED FEC AND FHC SEE DETAILS 10 AND 11 ON SHEET A200. 8. CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. GWB ABOVE CMU TO METAL DECK SIM OPP HAN'11 A A201 15B13 VOCATIONAL LEARNING 11B15 TRENCH JANITOR 16B13 b DF TABLE TABLE 30x60 3040 MATCH LINE — SEE SHEET 1A14 FIRE HOSE CABINET 17B13 SIMILAR GWB ONE SIDE FEC ROOM �15B15� FEC TRANSPORTATION AISLE 1A11A A201 1088 12B14 PARTIAL FIST FLOO LAYOUT PLA\ SCALE: 1 /8"=1'-0" FIRE HOSE CABINET 1A11A A203 FUR OUT WITH METAL STUDS AND GWB TO ALIGN WITH ADJACENT TYPE AWALL SYM REVISION A P-8 PRODUCT INTEGRATION CENTER W5005152 BY C/ROLLUDA APPROVED DATE SYM REVISION BY APPROVED DATE 09.26.17 6604 ' GISTER D A"CHITEfT RI it Ti�'N STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN D. PLAGENS DATE J. HILLIER CO\STUCTIO\S \OTES: BOEING TO PROVIDE AND INSTALL ALL FURNITURE, TABLES, CHAIRS, TYP. OPEN WALL AND PROVIDE BACKING AT NEW VIDEO MONITORS. PATCH AND REPAIR WALL TO MATCH EXISTING GWB FINISH. PAINT PER NOTES ON 1A11A. PROVIDE AND INSTALL NEW 7' X 12' WHITEBOARD. PBS SUPPLY 7013 SOUTH 216TH STREET KENT, WA 98032 253.395.5500 www.pbssupply.com INSTALL FROM 18" A.F.F. TO 8'-6" A.F.F NEW VIDEO WALL SYSTEM BY STAGE FRONT PRESENTATION. COORDINATE NEW A/V SYSTEM AND EQUIPMENT WITH STAGE FRONT PRESENTATION SYSTEM. WORK INCLUDES SCREEN, SCREEN MOUNTING, CAMERAS, PROJECTORS, MICROPHONES, VIDEO MONITORS AND BRANDING. NOTE: GENERAL CONTACTOR TO CONTRACT WITH STAGE FRONT PRESENTATIONS SYSTEMS FOR INSTALLATION OF A/V EQUIPMENT. COORDINATE INSTALLATION AND AND REQUIREMENTS FOR BACKING/MOUNTING EQUIPMENT. SEE SHEET PS100 IN THIS SET. STAGE FRONT PRESENTATION SYSTEM 6 SOUTHER OAKS DRIVE SAVANNAH, GA 31405 800.736.9242 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 09.26.17 1 KEY PLAN SCALE: NONE R C�U`�J �Lp' 8' 4' 0 4' 8' 16' art ®� JC SCALE: 1/8"=1' —0" Pe APPROVED BY DEPT. DATE CHECKED G. KRAPE ENGINEER T. DRAGOO SUBTITLE PARITAL FIRST FLOOR PLAN CURRENT REVISION SYMBOL W5005152 A DATE 09.26.17 CHECKED G. CULTUM 7.25.94 APPROVED APPROVED TITLE LAYOUT MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. B—C/12.4-16 PLANT 2 SHEET 1L11A JOB NO. W5005152 COMP NO. DWG NO. 14.01-1L11A c c r. c c z n T 1A11A }__ vT_/-1 1A11B 1A10A 1A10B 1Al2 1A13 1A14 1A15 1A16 1A17 1A18 1A19 KEY PLAN SCALE: NONE R C�U`�J �Lp' 8' 4' 0 4' 8' 16' art ®� JC SCALE: 1/8"=1' —0" Pe APPROVED BY DEPT. DATE CHECKED G. KRAPE ENGINEER T. DRAGOO SUBTITLE PARITAL FIRST FLOOR PLAN CURRENT REVISION SYMBOL W5005152 A DATE 09.26.17 CHECKED G. CULTUM 7.25.94 APPROVED APPROVED TITLE LAYOUT MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. B—C/12.4-16 PLANT 2 SHEET 1L11A JOB NO. W5005152 COMP NO. DWG NO. 14.01-1L11A c c r. c c z 12./ (EXPOSED STRUCTURE) FRAME OUT 12"x6" HIGH RETURN AIR OPENING ABOVE CEILING (EXPOSED STRUCTURE) FRAME OUT 48"x14' HIGH RETURN AIR OPENING ABOVE CEILING - (EXPOSED STRUCTURE) 13.2 nP I 5 1A281 A506 15/ J FRAME OUT 12"x12" RETURN AIR OPENINGS ABOVE CEILING 14.2 14. FRAME OUT 24"x12" HIGH RETURN AIR OPENING ABOVE CEILING L r J v FRAME OUT 12"x12" HIGH RETURN AIR OPENING ABOVE CEILING 15.2 15.E J T I L L✓_ TIP 8 AT 8'-2 1A281 A506 1 1 J (EXPOSED STRUCTURE) B� REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 09.26.17 LEGE\D: 4'-0"x2'-0" SUSPENDED CEILING GRID GWB CEILING 4'-0"x1'-0" FLUORESCENT LIGHT FIXTURE (RECESSED) 4'-0"x1'-0" FLUORESCENT LIGHT FIXTURE (SURFACE OR PENDANT MOUNT) 0 INCANDESCENT LIGHT FIXTURE ,'n' 41.1 TRACK LIGHTING FIXTURE F-0 SUPPLY AIR DIFFUSER RETURN AIR GRILLE ILLUMINATED EXIT SIGN (WALL OR CEILING MOUNTED) GE\HAL \OTES: 1. SEE SPECIFICATIONS DOCUMENT SECTION 00004 FOR ROOM FINISH SCHEDULE FOR CEILING HEIGHTS AND ROOM FINISHES. CEILING HEIGHTS ARE TAKEN FROM FINISH FLOOR HEIGHTS. 2. ALL ACOUSTIC TILE CEILINGS AND SUSPENSION SYSTEMS SHALL BE INSTALLED PER SPECIFICATION 09130. 3. ALL GYPSUM WALL BOARD CEILINGS TO BE FRAMED WITH STEEL STUD JOISTS UNLESS OTHERWISE INDICATED: — USE 4" METAL STUDS AT 16" O.C. FOR SPANS UP TO 7'-0" UNLESS OTHERWISE NOTED. — USE 6" METAL STUDS AT 16" O.C. FOR SPANS 7'-0" TO 10'-0" 0.C. UNLESS OTHERWISE NOTED. 4. REFER TO DRAWING A506 FOR CEILING DETAILS. 5. REFER TO DRAWING A200 FOR WALL TO FLOOR DETAILING. CO\S-RUCTIO\ NOT COORDINATE REMOVAL AND INSTALLATION OF NEW LIGHT FIXTURES AND DIFFUSERS. RELOCATE SPRINKLER HEADS AS REQUIRED BY NEW WALL INSTALLATION. REPLACE ANY BROKEN OR STAINED CEILING TILES. ARMSTRONG OPTIMA 2' X 4' SQUARE EDGE, WHITE PAINT EXISTING CEILING TILES AND GRID FLAT BLACK AT PROJECTION ROOM ONLY. 1 iECEI E.0 CITY OF TUKWILA 1 PERMIT CENTER KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1 /8"= 1! SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE B C REVISE OFFICE CAD CONVERSION P-8 PRODUCT INTEGRATION CENTER J#979061-00 W5005152 PJG CADDNW EC/ROLLUDA 4.15.97 4.21.98 09.26.17 ao STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN D. PLAGENS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER G. KRAPE SUBTITLE REFLECTED CEILING PLAN CURRENT REVISION W5005152 SYMBOLDATE C 09.26.17 CHECKED T. DRAGOO APPROVED G. CULTUM 7.25.94 APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ARCHITECTURAL MASTER COL. B—C/12.4-16 PLANT 2 SHEET 1A281A JOB NO. W5005152 COMP NO. DWG NO. 14.01-1A281A n I 1A281A0 1-_/-1 1A2816 1A280A 1A280B 1A282 1A283 1A284 1A285 1A286 1A1287 1A288 1A289 iECEI E.0 CITY OF TUKWILA 1 PERMIT CENTER KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1 /8"= 1! SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE B C REVISE OFFICE CAD CONVERSION P-8 PRODUCT INTEGRATION CENTER J#979061-00 W5005152 PJG CADDNW EC/ROLLUDA 4.15.97 4.21.98 09.26.17 ao STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN D. PLAGENS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER G. KRAPE SUBTITLE REFLECTED CEILING PLAN CURRENT REVISION W5005152 SYMBOLDATE C 09.26.17 CHECKED T. DRAGOO APPROVED G. CULTUM 7.25.94 APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ARCHITECTURAL MASTER COL. B—C/12.4-16 PLANT 2 SHEET 1A281A JOB NO. W5005152 COMP NO. DWG NO. 14.01-1A281A 10'-0" / / / / MONITOR A B C A B B C A B C A B n C A B W=ST WALL SCALE: 1 /4"=1'-0" ILEVATIO\ 1' 8'-0" X11 1A11A A370 MICROPHONE SOUND PANELS 12'-0" B B B B C C C C A A 1 A A I I L____J MONITOR EAST WALL ELEVATIO\ SOUND PANELS 3 SCALE: 1/4"= 1 '-0" 1A11ALA370 B B B B B C C C C C C A A A A A A 1 c 11" 6'-0" 1 A A A A A A CENTERED AT WALL RECESS \ / / / / B B MONITOR A A A // / \. B B B/ / B B 1 00 \OTTH WALL ELEVATI 2 SCALE: 1/4' =1'-0" i—n" 1A11AlA370 SCUTH WALL ELEVATIO\ SCALE: 1/4 '=1'-0" WHITE BOARD/MARKERWALL 1A11A A370 Iglamer CO\ST UCTIO S \OTES: PROVIDE AND INSTALL ACOUSTIC TILE ON EXISTING WALL. SONEX CONTOUR GLUE -ON TILE, 24" X 24", BASIX, LIGHT GREY AND MEDIUM GREY COLOR PATTERN AS FOLLOWS: A. LIGHT BLUE B. WHITE C. LIGHT GREY PROVIDE AND INSTALL WHITE BOARD AT EXSTING WALL. PBS SUPPLY 'MARKERWALL', W/ ALUMINUM TRIM, WHITE PBSSUPPLY.COM/DETAILS/MARKERWALLTACKWALL./ ISSUE FOR CONSTRUCTION 09.26.17 RE CEN 4D CON ©F T111.011..A r2ra 3 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION e�{NtIT CENTE4'2'0 2' 8' SCALE: 1 /4"=1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P-8 PRODUCT INTEGRATION CENTER W5005152 C/ROLLUDP 09.26.17 6604 V>, I GISTE`ED CHIT- T ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE INTERIOR ELEVATIONS CURRENT REVISION SYMBOL W5005152 DATE 09.26.17 STATE OF WASHINGTON APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ARCHITECTURAL MASTER COL. PLANT 2 SHEET A375 JOB NO. W5005152 COMP NO. DWG NO. 14.01-A375 CENTERED AT WALL RECESS B B B / \. B B B/ B B B 1 00 SCUTH WALL ELEVATIO\ SCALE: 1/4 '=1'-0" WHITE BOARD/MARKERWALL 1A11A A370 Iglamer CO\ST UCTIO S \OTES: PROVIDE AND INSTALL ACOUSTIC TILE ON EXISTING WALL. SONEX CONTOUR GLUE -ON TILE, 24" X 24", BASIX, LIGHT GREY AND MEDIUM GREY COLOR PATTERN AS FOLLOWS: A. LIGHT BLUE B. WHITE C. LIGHT GREY PROVIDE AND INSTALL WHITE BOARD AT EXSTING WALL. PBS SUPPLY 'MARKERWALL', W/ ALUMINUM TRIM, WHITE PBSSUPPLY.COM/DETAILS/MARKERWALLTACKWALL./ ISSUE FOR CONSTRUCTION 09.26.17 RE CEN 4D CON ©F T111.011..A r2ra 3 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION e�{NtIT CENTE4'2'0 2' 8' SCALE: 1 /4"=1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P-8 PRODUCT INTEGRATION CENTER W5005152 C/ROLLUDP 09.26.17 6604 V>, I GISTE`ED CHIT- T ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE INTERIOR ELEVATIONS CURRENT REVISION SYMBOL W5005152 DATE 09.26.17 STATE OF WASHINGTON APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ARCHITECTURAL MASTER COL. PLANT 2 SHEET A375 JOB NO. W5005152 COMP NO. DWG NO. 14.01-A375 HEAD FLASHING SEALANT BLOCKED OPENING PER STRUCTURAL FLASHING PLATE SILL FLASHING PE\ ETATI3 SCALE: 1 1/2"=1'-0" L_ 2" PIPE W/ 2" INSUL. JACKET DETAIL - SECTIO \ r-/6\ 1A11A A514 IJ +i METAL SIDING HEAD FLASHING 0 Q 0 P=\ETATIO\ SCALE: 1 1/2"=1'-0" + +j DETAIL - 2" PIPE W/ 2" INSUL. JACKET BLOCKED OPENING BEYOND PER STRUCT. STEEL ANGLE FRAMING BEYOND SILL FLASHING =VATI O \ ISSUE FOR CONSTRUCTION 09.26.17 OFTL1K 4 CITE 11<A 1 'CA PERMIT CENTER A514 A514 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P-8 PRODUCT INTEGRATION CENTER W5005152 C/R0LLUDA 09.26.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE MISCELLANEOUS DETAILS CURRENT REVISION SYMBOL W5005152 DATE 09.26.17 ENGINEER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER ARCHITECTURAL MASTER BUILDING 14-001 THOMPSON, WA SHEET A514 JOB NO. W5005152 COMP NO. DWG NO. 14-001—A514 r r c c c r r r c V ECHA\ICAL HVAC LEGE\ GENERAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES 24/12 Q RECTANGULAR DUCT, FIRST NUMBER 24/12 HUMIDISTAT CEILING INDICATES SIZE FOR SIDE SHOWN f 1 4D 24/12 >.< DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST RECTANGULAR DUCT, RADIUS VANED ELBOW cR b 240 9 ROUND DUCT, NUMBER INDICATES 240 DIAMETER I f EXTRACTION GRID THERMOSTAT, WALL 11111 b 24/120 S OVAL DUCT, FIRST NUMBER INDICATES 24/120MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER ff TEMPERATURE TRANSMITTER TT FLEXIBLE DUCT CONNECTION XSUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS '. .' '". SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY lot o CFM EXHAUST, RETURN OR SUPPLY AIR DUCT _ SIDEWALL OR REGISTER AND HAFLOWUST AIR GRILLE I ROUND, ELBOW FACING TOWARDS �� 100 CFM EXHAUST, RETURN OR SUPPLY AIR DUCT SCREENED OPENING AND CFM AIR FLOW _ -% ROUND, ELBOW FACING AWAY CFM SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 4) /EXHAUST --�- AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW .__ . FACING TOWARDS EXHAUST AIR OR RETURN AIR DUCT, I SQUARE OR RECTANGULAR, ELBOW FACING AWAY LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) TRANSITION RECTANGULAR TO _01 RECTANGULAR RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW F7 IZJ ,,r TRANSITION AT TAKE OFF RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED SQUARE OR RECTANGULAR / UNIT HEATER, HORIZONTAL _ _ _ -- lTRANSITION TO ROUND OR OVAL ‘ UNIT HEATER, VERTICAL PROJECTION F-7 LINED DUCT SOUND ATTENUATOR UP I__ 1 i OR DOWN 1 . DUCT OFFSET UP DOWN SD LINED DUCT WITH AXIAL FLOW FAN -(- OPPOSED BLADE DAMPER Cy' CENTRIFUGAL FAN t& CENTRIFUGAL FAN, INLET GUIDE VANES IA EXHAUST FAN SUPPLY AIR FLOW DIRECTION 11111- RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION PARALLEL BLADE DAMPER -:::=J- VOLUME DAMPER Nic f f 1111,111 D - DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) Ea- —1- BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) BDD AD OR AP • ACCESS DOOR (AD) OR ACCESS PANEL (AP) FD +I i + FIRE DAMPER (1 HOUR) f 1FD f FD2 i FIRE DAMPER (2 HOUR) iFD2 f f GENERAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES el Q 1' 11 MARK NUMBER HUMIDISTAT CEILING H 4D DUCT TYPE SMOKE DETECTOR PD RECTANGULAR DUCT, RADIUS VANED ELBOW cR I T H INL aim EXTRACTION GRID THERMOSTAT, WALL 11111 NIGHT THERMOSTAT FLEXIBLE DUCT -44 ----WI TEMPERATURE TRANSMITTER TT FLEXIBLE DUCT CONNECTION SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER AND CFM AIR FLOW lot o CFM SIDEWALL OR REGISTER AND HAFLOWUST AIR GRILLE �� 100 CFM SCREENED OPENING AND CFM AIR FLOW 10' 0 CFM SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 4) --�- .__ . SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) MK LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW F7 IZJ ,,r RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED / UNIT HEATER, HORIZONTAL _ -- i ‘ UNIT HEATER, VERTICAL PROJECTION F-7 LINED DUCT SOUND ATTENUATOR I__ 1 LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER AD SD LINED DUCT WITH AXIAL FLOW FAN Cy' CENTRIFUGAL FAN t& CENTRIFUGAL FAN, INLET GUIDE VANES IA EXHAUST FAN SUPPLY AIR FLOW DIRECTION --N--•-- RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION GENERAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING R el Q HUMIDISTAT, WALL MARK NUMBER HUMIDISTAT CEILING H 4D DUCT TYPE SMOKE DETECTOR PD DUCT TYPE HEAT DETECTOR cR STATIC PRESSURE REGULATOR T H TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED aim 0 THERMOSTAT, WALL ON NIGHT THERMOSTAT THERMOSTAT, CEILING T TEMPERATURE TRANSMITTER TT VAV BOX LEGEND 1ST CHARACTER: V= VARIABLE AIR TERMINAL UNIT VOLUME 2ND CHARACTER: F= FAN POWERED UNIT C= SHUTOFF UNIT 3RD CHARACTER: E= ELECTRIC HEAT W= HOT WATER HEAT C= NO HEAT COIL el MARK NUMBER SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION A MV AD ADD AF AFF AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTU H BW C Cv 'C CAP CC CCW CFM CI COND CONN CONT CPLG CW DA DB DBD DIA 0 DIS DIR DN DS DWG dB EA EAT EFF ELL ELEC ELEV, EL ESP EVAP EWT EXH EXIST EXT 'F FC FD FLR FCO FO B FOF FOIC FOT FPM FS FT FV GAL GPM GALV GA HC HD HORIZ HP HPC HR HVAC HPU HTG ID IE IGV INSUL IN ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CONDENSATE CONNECTION CONTINUED/CONTINUATION COUPLING CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DEIONIZED WATER SUPPLY DEIONIZED WATER RETURN DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH ENTER AIR TEMPERATURE CO EFFICIENCY ELBOW ELECTRICAL ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FORWARD CURVE WHEEL FIRE DAMPER FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FLOW SWITCH FEET FACE VELOCITY FPM GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INSULATION INCHES SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION KW KILOWATT KVA KILOVOLT -AMPERE LAT LBS, # LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NIC NO NTS NPSH OA OBD OF OS&Y OD OVHD PBD PD/AP PDI POC POS PRESS PRV PS PSIG PSV RA RECT REF REV RH RM ROT RPM RQD RTN RV SA SCFH SCFM SHC SHF SHT SO SOV SP SQ SS STL STRUC SW SUCT TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP UBD VAV VD VP VERT VTA VTR WB WG W/ WCO WHA LEAVING AIR TEMPERATURE CO POUNDS LEAVING WATER TEMPERATURE CO MIXED AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE REVERSE ACTING (CONTROLLER) RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN ROOF VENT SUPPLY AIR STANDARD CUBIC FEET/HR STANDARD CUBIC FEET/MIN SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SHEET SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD SUCTION TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL / RETURN AIR UP BLAST DISCHARGE VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WATER GAUGE (INCHES OF WATER) WITH WALL CLEAN OUT WATER HAMMER ARRE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW KR P-8 PRODUCT INTEGRATION CENTER W5005152 FSi AWL 3.31.95 09.26.17 08.26.17 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER DATE CHECKED SCHELLPFEFFER SUBTITLE GENERAL NOTES: DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. 2. SEE DRAWINGS M1 b AND M1 c FOR ADDITIONAL MECHANICAL LEGENDS AND ABBREVIATIONS. 3. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. 4. DIFFUSER SYMBOLS WITHOUT AIR FLOW DIRECTION ARROWS INDICATE AIR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). AIR FLOW ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. 5. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. ISSUE FOR CONSTRUCTION 09.26.17 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION HVAC LEGEND AND ABBREVIATIONS CURRENT REVISION W5005152 SYMBOL FSi consulting engineers Seattle, Washington Solutions 8c Service DATE 09.26.17 ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED 7/25/94 TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 MECHANICAL MASTER COL PLANT I SHEET MIA JOB NO. COMP NO. DWG NO. 14-001-M1 a VECHA\ICAL PIPI \G LECE\D GENERAL SYMBOL DESCRIPTION —q 1-- BREAK IN RPE I CROSSING LINES, NO CONNECTION I n DIRECTION OF FLOW SLOPE DIRECTION OF SLOPE, DOWN LAVATORY, ROUND COUNTER MOUNT AHU EQUIPMENT MARK NUMBER LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT EXIST EXISTING WORK ORD (OFD) /////r/ EXISTING TO BE REMOVED SAFETY EYE WASH FOUNTAIN °) HIDDEN OR BELOW GRADE — — --."0— IN-LINE RECIRCULATING PUMP CLD INSULATED PIPE —6 g-- >1 SHOWER STALL AND FIXTURE INSULATED PIPE WITH ELECTRIC HEAT TRACING —6 g-- URINAL, WALL HUNG —NEW NEW WORK c0 ,POC POINT OF CONNECTION -EP---PUMP COOLING TOWER FILTER RETURN FIXTURES SYMBOL DESCRIPTION ( CIRCULAR WASHFOUNTAIN U SEMI -CIRCULAR WASHFOUNTAIN CLEAN OUT, EXPOSED n ELECTRIC WATER COOLER CLEAN OUT, FLOOR Q LAVATORY, ROUND COUNTER MOUNT WCo CLEAN OUT, WALL LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT fel CD ORD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) CF SAFETY EYE WASH FOUNTAIN °) SAFEIY SHOWER AND EYE WASH FUNNEL DRAIN 1 SERVICE SINK, FLOOR MOUNT CLD C SERVICE SINK, WALL HUNG >1 SHOWER STALL AND FIXTURE —CLWS— FS URINAL, WALL HUNG O WATER CLOSET, WALL HUNG c0 WATER CLOSET, FLOOR MOUNT TRENCH DRAIN COOLING TOWER FILTER RETURN O CTFS— COOLING TOWER FILTER SUPPLY OO WR WASTE RECEPTOR, ROOF COOLING TOWER WATER RETURN WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT WASTE FITTINGS SYMBOL DESCRIPTION A 1/4 BEND 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR ll Co CLEAN OUT, EXPOSED AR FCO CLEAN OUT, FLOOR O ACID WASTE WCo CLEAN OUT, WALL CONDENSATE RETURN (GRAVITY) 400 CD FFD FUNNEL FLOOR DRAIN CF CHEMICAL FEED AUTOMATIC AIR VENT (WITH DRAIN) FUD FUNNEL DRAIN 0 CHILLED WATER SUPPLY CLD FD FLOOR DRAIN O COOLING WATER RETURN —CLWS— FS FLOOR SINK O D4 LATERAL ISI TRENCH DRAIN COOLING TOWER FILTER RETURN O CTFS— COOLING TOWER FILTER SUPPLY OO WR WASTE RECEPTOR, ROOF COOLING TOWER WATER RETURN WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT 111 CO CW— DOMESTIC COLD WATER PIPE IDENTIFICATION SYMBOL DESCRIPTION A COMPRESSED AIR, PLANT 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR —A(600)— COMPRESSED AIR, PLANT 600PSIG AR ARGON GAS - AW ACID WASTE E1 C CONDENSATE RETURN (GRAVITY) 400 CD CHEMICAL DRAIN CF CHEMICAL FEED AUTOMATIC AIR VENT (WITH DRAIN) —CHWR— CHILLED WATER RETURN —CHWS— CHILLED WATER SUPPLY CLD CLEAR WATER DRAIN —CLWR— COOLING WATER RETURN —CLWS— COOLING WATER SUPPLY CRV CORROSION RESISTANT VENT D4 CRW CORROSION RESISTANT WASTE CTFR— COOLING TOWER FILTER RETURN — CTFS— COOLING TOWER FILTER SUPPLY — —CTWR— COOLING TOWER WATER RETURN —CTWS— COOLING TOWER WATER SUPPLY CW— DOMESTIC COLD WATER FLOWMETER, VENTURI TYPE DEIONIZED WATER DI IIP— DISTILLED WATER DW F FIRE LINE, AHEAD OF ALARM VALVE FH FIRE HOSE CABINET PIPING D' FOR FUEL OIL RETURN —1..C1— FOS— FUEL OIL SUPPLY — FOV— FUEL OIL VENT — G NATURAL GAS -->i<1— NEEDLE VALVE GASEOUS NITROGEN GN2 HGD REFRIGERANT HOT GAS DISCHARGE — — HPC— CONDENSATE, STEAM (HIGH PRESSURE) — HPR— CONDENSATE RETURN (HIGH PRESSURE) — HPS STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) — HOT PROCESS WATER —HPW — —HPWC— HOT PROCESS WATER CIRCULATING HW DOMESTIC HOT WATER SUPPLY PRESSURE RELIEF VALVE / SAFETY VALVE HWC— DOMESTIC HOT WATER CIRCULATING — HWR— HEATING WATER RETURN HWS— HEATING WATER SUPPLY SOLENOID OPERATED VALVE IA INSTRUMENT AIR ID INDIRECT DRAIN IW INDUSTRIAL WASTE SWING CHECK VALVE WITH FLOW IWP— INDUSTRIAL WASTE PUMPED LIQUID NITROGEN LN2 LPC CONDENSATE, STEAM (LOW PRESSURE) — LIQUID PETROLEUM GAS LPG — LPS STEAM SUPPLY (LOW PRESS, 0-15 PSIG) — MPC CONDENSATE, STEAM (MEDIUM PRESSURE) — MPS STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) — OFD— OVERFLOW DRAIN PA PAINT BOOTH SERVICE AIR —PCWS— PROCESS COOLING WATER SUPPLY —PCWR— PROCESS COOLING WATER RETURN PIPE IDENTIFICATION SYMBOL DESCRIPTION PC CONDENSATE RETURN (PUMPED) PW PROCESS WATER RD ROOF DRAIN RDS— REFRIGERANT DISCHARGE RHG— REFRIGERANT HOT GAS RL- REFRIGERANT LIQUID RS— REFRIGERANT SUCTION (GAS) RWL RAIN WATER LEADER S SPRINKLER LINE SAN— SANITARY WASTE ABOVE GRADE OR FLOOR -- SAN -- SANITARY WASTE BELOW GRADE OR FLOOR SPD SUMP PUMP DISCHARGE STM — STEAM SUPPLY -- STS -- STORM DRAIN BELOW GRADE --- TP --- TRAP PRIMER v -- VENT VAC— VACUUM VPD— VACUUM PUMP DISCHARGE PIPE FITTINGS SYMBOL DESCRIPTION BELL & SPIGOT BLIND FLANGE BUSHING EXPANSION JOINT FLANGED FITTING —ESE— FLEXIBLE PIPE CONNECTION GROOVED COUPLING HB HOSE BIBB N HB HOSE BIBB - NON FREEZE X PIPE ANCHOR PIPE CAP SCREWED OR SOLDER JOINT D PIPE CAP, WELDED OR GROOVED tl PIPE CROSS +SR PIPE ELBOW, 90° SHORT RADIUS PIPE ELBOW, 90° LONG RADIUS PIPE ELBOW, REDUCING PIPE ELBOW, 45' 10 PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW, TURNED DOWN OR AWAY PIPE GUIDE PIPE HANGER x Y PIPING MATERIAL CHANGE, X TO Y 14 PIPE PLUG —D PIPE REDUCER CONCENTRIC PIPE REDUCER ECCENTRIC PIPE SUPPORT -F PIPE TEE, STRAIGHT —I-01 PIPE TEE, UP OR TOWARD —ID REDUCING PIPE FLANGE PIPE TEE, DOWN OR AWAY SCREWED FITTING OR AS SPECIFIED S SEISMIC HANGER PIPING SPECIALTIES PIPE FITTINGS SYMBOL DESCRIPTION 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR SOLVENT CEMENT - AIR DROP - HOSE, SIMPLEX / DUPLEX e /e E1 SPRING HANGER ANGLE GLOBE VALVE, ELEVATION / PLAN 400 —i F— UNION, FLANGED UNION, SCREWED AUTOMATIC AIR VENT (WITH DRAIN) 11-- BACKFLOW PREVENTER WELDED FITTING SOLDERED FITTING o o PIPING SPECIALTIES SYMBOL DESCRIPTION ---1>T< 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR A /A AIR DROP - HOSE, SIMPLEX / DUPLEX e /e AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX T 1=0 ANGLE GLOBE VALVE, ELEVATION / PLAN 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) —eV AUTOMATIC AIR VENT (WITH DRAIN) --I BACKFLOW PREVENTER BFP I--- BALANCE VALVE WITH METERING PORTS BALANCE VALVE W/0 METERING PORTS D4 -10I-/-1¢1- BALL VALVE, OPEN / CLOSED BUTTERFLY VALVE A-- — ---h�4— COOLING COIL CHILLED WATER —1 -1 FLOAT VALVE —a FLOWMETER, VENTURI TYPE FLOWMETER ORIFICE IIP— --/►�- GATE VALVE, OPEN / CLOSE A GATE VALVE, OUTSIDE SCREW AND YOKE GATE VALVE, WITH HOSE CONNECTION D' -Dol-/-G4- GLOBE VALVE, OPEN / CLOSED —1..C1— HEATING COIL -N-- / 1 LIFT CHECK VALVE -MAV MANUAL AIR VENT (WITH DRAIN) IN MOTOR OPERATED VALVE -->i<1— NEEDLE VALVE 0 NITROGEN DROP O NITROGEN OUTLET —101— PETCOCK tH$FC PETE'S PLUG, WITH BALL VALVE CI— PLUG VALVE/STOP COCK If, PRESSURE GAUGE WITH VALVE PRESSURE REGULATING VALVE W/EXT PRESS TAP IC -1 15. PRESSURE REGULATING VALVE (SELF CONTAINED) 21 PRESSURE RELIEF VALVE / SAFETY VALVE QUICK OPENING VALVE t<1 QUICK CLOSING VALVE, FUSIBLE LINK _RI SOLENOID OPERATED VALVE STEAM TRAP '1 v— SWING CHECK VALVE WITH FLOW PIPING SPECIALTIES SYMBOL DESCRIPTION TEST PLUG THERMOMETER, LINE MOUNT THERMOMETER, SEPARABLE WELL MOUNT TRAP, FLOAT TP TRAP SEAL PRIMER VALVE —I V-11— UNCLASSIFIED VALVE VACUUM BREAKER VACUUM DROP (LAB VAC) 0 VACUUM OUTLET (LAB VAC) HARD PIPED VACUUM CLEANING OUTLET VALVE BOX VALVE IN RISER (TYPE SPECIFIED) WATER HAMMER ARRESTOR WYE STRAINER (WITH DRAIN VALVE) FIRE PROTECTION SYMBOL DESCRIPTION 2 WAY EARTHQUAKE BRACING WELDING SYMBOL DESCRIPTION ROOT OPENING DEPTH OF FILLING FOR PLUG AND SLOT WELDS EFFECTIVE THROAT CONTOUR SYMBOL FINISH SYMBOL F SIZE OR STRENGTH FOR CERTAIN WELDS A E){r(4 (N) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED BASIC WELD SYMBOL OR DETAIL REFERENCE TAIL (MAY BE OMMITTED WHEN REFERENCE IS NOT USED SPECIFICATIONS, PROCESS OR OTHER REFERENCE GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL ARROW CONNECTING REFERENCE LINE TO ARROW SIDE OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS X 4 WAY EARTHQUAKE BRACING BACK WELD ALV ALARM VALVE, WET FILLET WELD ® ASR AUTOMATIC SPRINKLER RISER NINE PLUG OR SLOT WELD DRY PIPE VALVE 11 SQUARE WELD r, ELECTRIC BELL 0 SPOT OR PROJECTION WELD EXISTING SPRINKLER HEADS (TO REMAIN) xx EXISTING SPRINKLER HEADS (REMOVE) FHC FIRE HOSE CABINET FDC Y FIRE DEPARTMENT CONNECTION, WALL TYPE FIRE DEPARTMENT CONNECTION, YARD TYPE LJ FDC FIRE DEPARTMENT CONNECTION, FLUSH 4-1 FH FIRE HYDRANT - 2 HOSE OUTLET FH FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER CONNECTION FLOW SWITCH HALON SYSTEM AUTOMATIC DISCHARGE STATION L. HALON SYSTEM, MANUAL DISCHARGE STATION —EHC pcc GROOVED COUPLING, GROOVED CAP MONITOR SWITCH y PN POST INDICATOR VALVE, YARD SPRINKLER HEAD, DRY PENDENT —O®— SPRINKLER HEAD, OVER AND UNDER SPRINKLER HEAD, PENDENT, IN LINE, NEW SPRINKLER HEAD, PENDENT, OFFSET, NEW SPRINKLER HEAD, SIDEWALL, PENDENT, NEW 0 SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW —d SPRINKLER HEAD, UPRIGHT, NEW THRUST BLOCK (tWIV WALL INDICATOR VALVE, PLAN / ELEVATION T WMG WATER MOTOR GONG TAMPER SWITCH SSU STANDARD SPRINKLER, UPRIGHT (165T) SSPR STANDARD SPRINKLER, PENDENT, RECESS MOUNTED (165'F) ISU INTERMEDIATE SPRINKLER, UPRIGHT (212T) ISPR INTERMEDIATE SPRINKLER, PENDENT, RECESS MOUNTED (212°F) GENERAL NOTES: 1. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. HSU HIGH SPRINKLER, UPRIGHT (286°F) ISSUE FOR CONSTRUCTION 09.26.17 i SCal OF"TUK,NILA p>cRiVliT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION Q FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) P-8 PRODUCT INTEGRATION CENTER W5005152 MJC KW FSi KR AWL 3.31.95 09.26.17 09.26.17 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER DATE CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE HVAC LEGEND AND ABBREVIATIONS CURRENT REVISION SYMBOL W5005152 DATE 09.26.17 7/25/94 TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 COL THOMPSON, WA SHEET M16 JOB NO. COMP NO. DWG NO. 14-001-M1 b I\STU V E\ T AND CONTOLS LEGEND INSTRUMENT IDENTIFICATION SYMBOL DESCRIPTION O LOCAL FIELD MOUNTED INSTRUMENT INCLUDING TRANSMITTER FOR SINGLE MEASURED VARIABLE (1:::) EXISTING INSTRUMENT ••LOCAL FIELD MOUNTED INSTRUMENT FOR TWO MEASURED VARIABLES OR MORE THAN ONE FUNCTION 0 PANEL MOUNTED INSTRUMENT FOR SINGLE MEASURED VARIABLE e PANEL MOUNTED INSTRUMENT LOCATED ON FACE OF LOCAL CONTROL PANEL 00 PANEL MOUNTED INSTRUMENT FOR TWO MEASURED VARIABLES OR MORE THAN ONE FUNCTION EQUIPMENT PACKAGE WHERE NOTED E ENERGY MANAGEMENT CONTROL SYSTEM FUNCTION (FMCS) USER'S CHOICE � J PNEUMATIC SIGNAL i INDICATING LIGHT CPDIRECT CONNECTION PRESSURE SYMBOL DESCRIPTION Ill ANALOG INPUT, SIGNAL TO EMCS DIAPHRAGM SEAL CONNECTION ORIFICE PLATE OR RESTRICTION DEVICE SO CONTROL AIR SOURCE DI TEMPERATURE SYMBOL DESCRIPTION Al ANALOG INPUT, SIGNAL TO EMCS TEMPERATURE ELEMENT W/ THERMO–WELL ORIFICE PLATE OR RESTRICTION DEVICE FLOWS SYMBOL DESCRIPTION Al ANALOG INPUT, SIGNAL TO EMCS AO ORIFICE PLATE OR RESTRICTION DEVICE SO CONTROL AIR SOURCE DI DIGITAL INPUT, SIGNAL TO EMCS IN LINE FLOW ELEMENT DIGITAL OUTPUT, SIGNAL FROM EMCS DASHED LINE INDICATES BEHIND PANEL MOUNTINGS CONTROL METHODS SYMBOL DESCRIPTION Al ANALOG INPUT, SIGNAL TO EMCS AO ANALOG OUTPUT, SIGNAL FROM EMCS SO CONTROL AIR SOURCE DI DIGITAL INPUT, SIGNAL TO EMCS DO DIGITAL OUTPUT, SIGNAL FROM EMCS ELECTRICAL SIGNAL ELECTRIC ACTUATED EQUIPMENT PACKAGE WHERE NOTED E MAIN PROCESS USER'S CHOICE USER'S CHOICE PNEUMATIC SIGNAL E/P ELECTRIC TO PNEUMATIC I/P 120V POWER ELECTRONIC TO PNEUMATIC REFERENCE NO. O .3111111111110 INTERLOCK E VOLTAGE MOTOR ACTUATED M F FLOW RATE RATIO (FRACTION) MOTOR CONTROL CENTER MCC G USER'S CHOICE PNEUMATIC ACTUATED P H HAND VARIABLE SPEED DRIVE VSD I CMCS CENTRAL MANAGEMENT CONTROL SYSTEM INDICATE LINES SYMBOL DESCRIPTION SUCCEEDING LETTERS CAPILLARY TUBING, (FILLED SYSTEM) X X READOUT OR PASSIVE FUNCTION CONNECTION TO PROCESS MECHANICAL LINK OR INSTRUMENT INPUT MODIFIER ^\'-`1-' ELECTRIC HEAT TRACE ALARM ELECTRICAL SIGNAL EQUIPMENT PACKAGE WHERE NOTED BURNER, COMBUSTION MAIN PROCESS USER'S CHOICE USER'S CHOICE PNEUMATIC SIGNAL // // SECONDARY PROCESS CONTROL 120V POWER —0 0 REFERENCE NO. .3111111111110 CONTINUED ON SHEET NO. E INSTRUMENT SOCIETY OF AMERICA TABLE REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW P-8 PRODUCT INTEGRATION CENTER W5005152 FSi KR AWL 3.31.95 09.26.17 09.26.17 SIGNED ACCEPTABILITY THS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER DATE ISSUE FOR CONSTRUCTION 09.26.17 RECENEDILA CITY OF TUK, PERMIT CENTER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE INSTRUMENTATION LEGEND AND ABBREVIATIONS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION 0 FSi consulting engineers Seattle, Washington CURRENT REVISION W5005152 SYMBOL Solutions & Service DATE 09.26.17 7/25/94 TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 COL THOMPSON, WA SHEET Mlc JOB NO. COMP NO. DWG NO. 14-001–M1 c IDENTIFICATION LL I I ERS FIRST LEITER SUCCEEDING LETTERS MEASURED OR INITIATING VARIABLE MODIFIER READOUT OR PASSIVE FUNCTION OUTPUT FUNCTION MODIFIER A ANALYSIS ALARM B BURNER, COMBUSTION USER'S CHOICE USER'S CHOICE USER'S CHOICE C USER'S CHOICE CONTROL D USER'S CHOICE DIFFERENTIAL E VOLTAGE SENSOR (PRIMARY ELEMENT) F FLOW RATE RATIO (FRACTION) G USER'S CHOICE GLASS, VIEWING DEVICE H HAND HIGH I CURRENT (ELECTRICAL) INDICATE J POWER SCAN K TIME, TIME SCHEDULE TIME RATE OF CHANGE CONTROL STATION L LEVEL LIGHT LOW M USER'S CHOICE MOMENTARY MIDDLE, INTERMEDIATE N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE 0 USER'S CHOICE ORIFICE, RESTRICTION P PRESSURE, VACUUM POINT (TEST) CONNECTION Q QUANTITY INTEGRATE, TOTALIZE R RADIATION RECORD S SPEED, FREQUENCY SAFETY SWITCH T TEMPERATURE TRANSMIT U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION V VIBRATION, MECHANICAL ANALYSIS VALVE, DAMPER, LOUVER W WEIGHT, FORCE WELL X UNCLASSIFIED X AXIS UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED Y EVENT, STATE OR PRESENCE Y AXIS RELAY, COMPUTE CONVERT Z POSITION, DIMENSION Z AXIS DRIVER ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW P-8 PRODUCT INTEGRATION CENTER W5005152 FSi KR AWL 3.31.95 09.26.17 09.26.17 SIGNED ACCEPTABILITY THS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER DATE ISSUE FOR CONSTRUCTION 09.26.17 RECENEDILA CITY OF TUK, PERMIT CENTER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE INSTRUMENTATION LEGEND AND ABBREVIATIONS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION 0 FSi consulting engineers Seattle, Washington CURRENT REVISION W5005152 SYMBOL Solutions & Service DATE 09.26.17 7/25/94 TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 COL THOMPSON, WA SHEET Mlc JOB NO. COMP NO. DWG NO. 14-001–M1 c AIS HANDLING UNIT (AHU) SCHEDULE MARK LOCATION (SHEET #) MARKDWG NUMBER MBH FANS HOT WATER COILS/PREHEAT COILS COOLING WATER COILS LWT (7 GPM MOUNTING H�E�T MOTOR REMARKS MOTORS RPM REMARKS 1M12 SUPPLY FAN SECTION RETURN FAN SECTION 60 AIR HOT WATER CAPACITY ENT AIR LV AIR EWT (7) LWT ('F) MAX FACE VEL (FT/MIN) DH -3 WTR AIR GPM VOLT HZ PH 170 NO ROWS MAX PD (FT WATER) PD (IN WO) CAPACITY (BTU/HR) EAT (°F) LAT ('F) PD (IN WG) GPM EWT CO LWT ('F) MAX PD (FT WATER) FACE VEL MAX (FT/MIN) NO ROWS SENSIBLE (BTU/HR) BTU/ HR) TOTAL (BTU/HR) DB (T) WB (T) DB (T) WB ('F) CFM TOTAL STATIC PRESSURE (INNWG) DIA (IN) MAX. OUTLET VELOCITY (ET/MIN) RPM HP MIN OA CFM EX SP (INCHES WG) DIA (IN) RPM HP DH -7 1M19 15400 690 60 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-14 RFM 10 68600 1.8 54 1/4 3000 - 100 61700 0.8 66 - 30 740900 70 80 37 240 200 12 650 1 AHU-15 RFM10 68600 1.8 54 1/4 3000 - 100 61700 0.8 66 - 30 593000 70 78 30 240 200 12 650 - 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-16 RFM 10 68600 1.8 54 1/4 3000 - 100 61700 0.8 66 - 30 593000 70 78 30 240 200 12 650 - 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-17 RFM 10 76200 2.1 54 1/4 3000 - 100 68600 1.4 66 - 40 658400 70 78 33 240 200 12 650 - 914400 1097300 74 61 62 56.2 46 56 500 12 - 219 - - - - AHU-18 RFM11 68600 1.8 54 1/4 3000 - 100 61700 0.8 66 - 30 593000 70 78 30 240 200 12 650 - 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-19 RFM11 76200 2.1 54 1/4 3000 - 100 68600 1.4 66 - 40 823000 70 80 41 240 200 12 650 - 914400 1097300 74 61 62 56.2 46 56 500 12 - 219 - - - - AHU-20 RFM11 76200 2.1 54 1/4 3000 - 100 68600 1.4 66 - 40 656400 70 78 33 240 200 12 650 - 914400 1097300 74 61 62 56.2 46 56 500 12 - 219 - - - - AHU-21 RFM11 67000 1.8 54 1/4 - - 60 61700 0.8 66 448 30 593000 70 78 37 240 200 12 650 - 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-22 RFM11 67000 1.8 54 1/4 - - 60 61700 0.8 66 448 30 593000 70 78 37 240 200 12 650 - 889000 987800 74 61 62 56.2 46 56 500 12 - 197 - - - - AHU-23 RFM11 72000 2.5 54 1/4 - - 75 68600 0.8 66 - 40 823000 70 80 41 240 200 12 650 - 914400 1097300 74 61 62 56.2 46 56 500 12 - 219 - - - - AHU-30 4M 10 22000 5.65 36 - 1235 30 3640 16450 1.35 30 830 7.5 508800 4265.4 .25 16 200 136 .25 - 1 521600 629000 79 65 55 54.5 46 56 544 6 13.5 .74 126 274 460 460 60 60 3 3 HAAKON AIRPAK 7404 CFM (PREHEAT), COILS: COOLING-TRANE TYPE WL 2 30X85, 108 FPF. HEATING-TRANE TYPE WC, W/PF FINS (2) 30X85, 80 FPF HAAKON AIRPAK 15039 CFM (PREHEAT_) COILS: COOLING-TRANE TYPE W (2) 42X120, 107 FP . HEATING-TRANE TYPE W, W/PF FINS (2) 42X12. 80 FPF. AHU-31 4M10 35819 5.65 49 - 943 60 9880 31671 1.35 44 505 10 1160000 42 69 .08 43.4 200 147 .91 - 1 1053000 1369000 79.7 66.1 55.5 54.8 46 56 564 6 20 .64 AHU-32 AHU-33 4M11 4M11 20472 1160 5.65 36 - 1286 40 5000 19548 1.35 33 738 7.5 630100 42 71.5 .09 22.0 200 143 .36 - 1 613300 767300 79.1 65.5 55.3 54.7 46 56 560 6 17.5 .79 153.5 460 60 3 HAAKON AIRPAK 9026 CFM PREHEAT) TYPE WL, 2) 33X89, 110 F. HEATING-TRANE COILS: COOTYPE YPE WC W W/ PF FENS ) 33X89. 80 FPF. 1.0 12X9 - 702 1/2 1020 - - - - - 45400 60 91 1.0 200 120 1.6 350 - 43600 59800 84.4 67.9 53.7 53.6 46 56 350 8 5.3 - 11.7 120 60 1 TRANE BLOWER COIL BCHA54 W/MIXING BOX AHU-34 M1 M17 25000 2.5 30 AF 2238 1150 25 5000 N/A N/A N/A N/A N/A 969000 68 103.7 •13 97 200 180 6.0 700 1 779100 800800 78.4 61.4 50 48.9 46 56 505 6 23.7 .65 160.2 460 60 3 TRANE MODULAR UMAT_E_CHANGER, SIZE 50, COILS: COOLING- TYPEWCW/SF 'F, 9.FPF9.5, 123 FPF. HEATING-TRANE AHU-35 (NOTE 1) 1M16 25000 NA NA NA 850 7.5 3000 N A / N A / N/A N/A N/A 1100000 70 111 NA 110 200 180 5.6 1090 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 460 60 3 WING MODEL FASHC FRESH AIR SUPPLY UNIT, SIZE 44, WITH 8R REVOLVING DISCHARGE, ROOF MOUNTED INTAKE, ROOF CURB, CLEANABLE FILTERS AND MIXING BOX AHU-36 4M10 800 1.0 9X9 1063 1/4 - - - - - - - - - - - - - - 21800 34500 85 71 59.7 58.2 46 56 288 2.6 - 6.8 120 60 1 TRANE BLOWER COIL BCHA36 W/FILTER RACK NOTE 1 (TO BALANCER): WHEN EF -8 IS RUNNING, MINIMUM OUTSIDE AIR FOR AHU-35 IS 8000 CFM. SEE SHEET M317. DOOR HEATH (DH) SCHEDULE MARK LOCATION (SHEET #) CFM MBH EAT ('F) LAT ('F) EWT (T) LWT (7 GPM MOUNTING H�E�T MOTOR REMARKS HP RPM DH -1 1M12 15400 690 60 101 200 170 46.5 14 2 - HP -1-1 DH -3 1M10 9800 463 60 103 200 170 31.5 9.6 1 - PUY-A3ONHA3 DH -5 1M15 15400 690 60 101 200 170 46.5 14 2 - 15.1 DH -6 1M15 15400 690 60 101 200 170 46.5 14 2 - DH -7 1M19 15400 690 60 101 200 170 46.5 16 2 - SYM AR HANDLING UNIT (AHU) SCHEDULE INDOOR UNIT OUTDOOR UNIT TAG AREA SERVED MAKE MODEL COOLING CAPACITY ELECTRICAL DATA TAG LOCATION MODEL ELECTRICAL DATA REMARKS ENTERING DB/WB TOTAL (MBH) SENSIBLE (MBH) SEER VOLTS/PH MCA WEIGHT ENTERING DB/WB VOLTS/PH MCA WEIGHT HP -1-1 DATA CLOSET 13B16 MITSUBISHI PKA-A3OKA 80/67 30,000 27,750 15.5 208/1 1 53 CU -4-1 LEVEL 4 PUY-A3ONHA3 95/75 208/1 25 163 1,2,3,4,5,6,7,8,910 HP -1-2 EQUIPMENT 11B14 MITSUBISHI MSY-D36NA-8 80/67 34,600 34,600 15.1 208/1 1 40 CU -1-2 LEVEL 1 MUY-D36NA-1 95/75 208/1 21 126 1,2,3,4,5,6,7,8,9,10 NOTE 1: INDOOR UNIT WIRING AND DISCONNECT BY E.C. INDOOR POWER SUPPLY FROM OUTDOOR UNIT. SEE INSTALLATION MANUAL FOR DETAIL. NOTE 2: P.C. TO ROUTE CONDENSATE TO APPROVED PLUMBING RECEPTICAL. NOTE 3: NO SPRING OR NEOPRENE ISOLATION REQUIRED NOTE 4: T -STAT OR SENSOR PROVIDED WITH INDOOR UNIT. NOTE 5: OUTDOOR UNIT WIRING AND DISCONNECT BY E.C. SINGLE POINT POWER CONNECTION. POWER WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY E.C. NOTE 6: EER AND SEER RATINGS PER ARI STANDARDS. NOTE 7: E.C. TO PROVIDE POWER AND WIRING. NOTE 8: REFRIGERANT TYPE R -410A NOTE 9: LOW VOLTAGE CONTROL WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY C.C. NOTE 10: INDOOR UNIT SHOULD HAVE CONDENSATE PUMP OPTION. REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RECORD DRAWING (FDS) P-8 PHASE 2 - DCN 1 MJC KW CEI KR MS 03.31.95 02.24.11 RECORD DRAWING B P-8 PRODUCT INTEGRATION CENTER W5005152 DLR GROUP FSi JH AWL 07.08.11 09.26.17 0926.17 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G. MCCLUNG DATE ISSUE FOR CONSTRUCTION 09.26.17 RECEIVED CITY OF TUKWIL.A PERMIT CENTER CHECKED SCHELLPFEFFER SUBTITLE EQUIPMENT SCHEDULES REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION CURRENT REVISION SYMBOL W5005152 FSi consulting engineers Seattle, Washington Solutions & Service 3 DATE 09.26.17 ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED 07.25.94 TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 THOMPSON, WA SHEET M2A JOB NO. COMP NO. DWG NO. 14-001-M2A / "�1� 12./1 u 3 ENCLOSURE 3 n 1 - FIRE FIRE RISER CHASE 1 312 1 O O O 1 3 1" 1" \ a.REAK ROC 2 1 L 1" 1" 13.2 13./1 c` S CORRIDOR 1031 1' 1' i 1/1.2 T 11% RISER SV403 15.2 15.E „ OPEN OFFICE 1/4" 12B13 JAN „ WONS 1v313 1 1" 'R 71 21 2 TRA I SPORTAT1ON AISLE 1088 1 _a » 1" } ft 4 SYM REVISION BY APPROVED DATE SYM REVISION C D REARRANGE OFFICE AS -BUILD REMODEL QA OFFICE CAD CONVERSION AIRPLANE COOLING - RECORD DRAWING J#979061-02 J#979060-02 J#D83P0202 11347785 GAVRAS GAVRAS GAVRAS CADDNW HGI GAVRAS GAVRAS GAVRAS 4.07.97 6.06.97 3.02.98 4.23.98 E P-8 PRODUCT INTEGRATION CENTER W5005152 BY FSi APPROVED DATE AWL 09.26.17 SEL 09.28.12 FIRE R;SER CH!SE CAT IONAL ZING » r „ 30X70 1 J JiITOR 0 CONFERENCE \ ROOM r 15B15N CNI IOW REMOVAL 09.26.17 SIGNED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN V.C. QUEROL DATE 1" ISSUE FOR CONSTRUCTION 09.26.17 CHECKED SUBTITLE FIRE PROTECTION PLAN GENERAL NOTES: 1 PIPING SHALL BE SCHEDULE 40, ASTM A106 SEAMLESS BLACK CARBON STEEL PIPE. 2 FITTING SHALL BE CLASS 125 SCREWED, PER ASME/ANSI B16,4, CAST IRON PER ASTM A126 CLASS B. 3 ALL WORK SHALL CONFORM TO 1997 NFPA 13 AND ALL APPLICABLE CODES AND STANDARDS. 4 NOTIFY BOEING FIRE DEPARTMENT 24 HOURS PRIOR TO SYSTEM SHUTDOWN. 5. SEE DRAWING 14-013—UGM260 FOR FIRE PROTECTION YARD PIPING. 6. SUBMIT SHOP DRAWINGS FOR BOEING AND FM GLOBAL APPROVAL PRIOR TO FABRICATION AND INSTALLATION. REMOVAL NOTES: REMOVE SPRINKLER HEAD AND CAP PIPE AT BRANCH PIPING. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila AUILDING ptVISION 1. T n - ,,,,,/ ' M261A ^ v 1-_,H 1M2616 -H 1M260A 1M260B 1M262 1M263 1M264 1M265 1M266 1M267 1M268 1M269 I- 8' 4' 0 4' 8' 16' PI CITY OF TUB F ft L� PERMIT CENTER �-o O FSI consulting engineers Seattle, Washington Solutions & Service CURRENT REVISION SYMBOL 11347785 E DATE 09.26.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 MECHANICAL MASTER COL. B—C/12.4-16 THOMPSON, WA SHEET 1 M26IAR JOB NO. COMP NO. DWG NO. 14-001-1M26 1AR EQUIPMENT MUST BE CONTAINED WITHIN THIS AREA MAINTENANCE CLEARANCES 1 2 . FOR ACYD12 13.2 1T/ 1/1.2 1 CYD1 DAMPER 1— L ND CD -2, SEE M3$'*� OR'"SEUENCE 3/4"0 CONDENSATE DRAIN ACCESS DOOR (ON BOTTOM OF DUCT) CAPPED FOR EMERGENCY CONNECTION TO MOBILE COOLING UNIT, SEE 0 1M10A M530 EF 1572 400 CFM 15/ FIRE SL TYP 8 14/8 12 6 FOR R 48/14 TRANS DUCT UTILI TRENC 125 C (TYP 8/10 Ii0-416116. 160 CFM TYP 4 78/14 TRANSFER DUCT 41/12,o- UP TO 220 FIRE DAMPER AT FLOO PENETRATION n 31/12 -8- MATCHLINE - FOR CONTINUATION SEE SHEET EA 300 CFM 5 (TYP 2) TRANSPORTATION A FOR FLEX AND DUCT DETAILS 1, ON SHEET COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH CONNECTION DETAIL, SEE 2, AND 3 M530 MOTE WALL MOUNTED START/STOP AND OLUME CONTROL FOR POSITION 2. SEE 300 FOR SEQUENCE OF OPERATION EDGE OF WALKWAY 12"0 ROUTED TO POSITION 3 ACCESS HATCH 12"O ROUTED TO POSITION 2 ACCESS HATCH POSITIO\ 2 REVIEWED FOR CODE COMPLIANCE APPROVED Npl 21 2011 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 09.26.17 LEGEND: 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GENERAL NOTES: 1. SEE SHEET 1M10 FOR NOTES. 2. BALANCE DUCTWORK TO CFM INDICATED. CONSTRUCTION NOTES: RELOCATE EXISTING DIFFUSER TO LOCATION SHOWN AND ALIGN WITH CEILING. EXTEND DUCTWORK TO CONNECT TO DIFFUSER LOCATION. MOUNT ABOVE DOOR. FIELD COORDINATE EXACT MOUNTING LOCATION. PUMP CONDENSATE TO THE NEAREST JANITORS CLOSET MOP SINK. TERMINATE WITH AIR GAP. COORDINATE REFRIGERANT PIPE ROUTING W/ ARCHITECT AND WALL TYPE. SIZE PIPING PER MANUFACTURERS INSTRUCTIONS. FLOOR MOUNT CONDENSING UNIT, COORDINATE MOUNTING LOCATION WITH BOEING. MAINTAIN REQUIRED CLEARANCES. / CONNECT 8"95 DUCT TO EXISTING DUCTWORK. BALANCE TO CFM INDICATED. RELOCATE TEMPERATURE SENSOR TO LOCATION SHOWN. 8 RELOCATE DIFFUSER TO LOCATION SHOWN. CONNECT DUCT TO DIFFUSER. TIE TEMPERATURE SENSOR TO EXISTING EMCS SYSTEM AND MONITOR ROOM TEMPERATURE AND THE UNIT FAULT ALARM. 1> PROVIDE 1/2" THICK ARMACELL 'ARMAFLEX' INSULATION ON ALL REFRIGERANT PIPING WITH 'ARMAFLEX WB FINISH' UV PROTECTION COATING ON ALL EXTERIOR PIPING. 112.4 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" RECEIVED CITY OF TUK\VILA PEERIVIIT CENTER O 8 FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE PHASE 2B HIGH BAY RENOVATION - RECORD DWG 11347785 A P-8 PRODUCT INTEGRATION CENTER W5005152 FSi FSi REG AWL 01.31.12 09.26.17 09.26.17 MEM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DUCTWORK PLAN CURRENT REVISION S W5005152 YMBOL A DATE 09.26.17 APPROVED BY DEPT. DATE ENDER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 COL B—C/12.4-16 THOMPSON, WA SHEET 1M11A JOB NO. COMP NO. DWG NO. 14-001-1M11A --H 1M10A 1M1OB /1M11A// 1M11B 1 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" RECEIVED CITY OF TUK\VILA PEERIVIIT CENTER O 8 FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE PHASE 2B HIGH BAY RENOVATION - RECORD DWG 11347785 A P-8 PRODUCT INTEGRATION CENTER W5005152 FSi FSi REG AWL 01.31.12 09.26.17 09.26.17 MEM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DUCTWORK PLAN CURRENT REVISION S W5005152 YMBOL A DATE 09.26.17 APPROVED BY DEPT. DATE ENDER CHECKED APPROVED APPROVED TITLE P-8 PRODUCT INTEGRATION CENTER MECHANICAL MASTER BUILDING 14-01 COL B—C/12.4-16 THOMPSON, WA SHEET 1M11A JOB NO. COMP NO. DWG NO. 14-001-1M11A P8 Product Integration Center\_Drawings\14-01—E1.dwg I:\ES\Projects\17\171-062 RA N N 6; N GROUNDING 6 GROUND CABLE PIGTAIL (#4/0 UON) GROUND CABLE (UNDERGROUND #4/0 UON) INSULATED GROUND BUS BAR GROUND CABLE CONNECTION G =G= CB 100AF 100AT GROUND ROD CONNECTION GROUNDING TEST WELL GROUNDING TRIAD 10'-0" SPACING POWER - GENERAL PANELBOARD, 208Y/120V, 3 PHASE INDICATES SHUNT -TRIP) ( s PANELBOARD, 480Y/277V, 3 PHASE EQUIPMENT IDENTIFICATION "X" DENOTES EQUIPMENT TYPE "Y" DENOTES EQUIPMENT NUMBER 100AF ENCLOSED CIRCUIT BREAKER 100AT FRAME RATING/TRIP RATING CB ® CKT. BKR. ENCLOSURE WITH SHUNT -TRIP DJ 100 100 DISCONNECT SWITCH (FUSED OR NON-FUSED) SWITCH RATING/FUSE RATING. 30AMP, 3POLE UON. IZP COMBINATION MOTOR STARTER. SIZE 1 UON. MANUAL MOTOR STARTER © TRANSFORMER (SIZE AS SHOWN, IN KVA) TRANSFORMER (SIZE AS SHOWN, IN KVA) O 4 C JUNCTION BOX, FLUSH OR CONCEALED. FIELD SIZED PER THE NEC. ON-OFF SELECTOR SWITCH SINGLE MOMENTARY PUSH BUTTON STATION PUSHBUTTON STOP -START STATION 480 VOLT MOTOR (SIZE AS NOTED) 208 OR 240 VOLT MOTOR (SIZE AS NOTED) 120 OR 277 VOLT MOTOR (SIZE AS NOTED) POWER FACTOR CORRECTION CAPACITOR TELEPHONE/POWER POLE TIME CLOCK CONTACTOR RACEWAYS CONDUIT NOT BURIED (INCLUDING ABOVE SUSPENDED CEILING & UNDER RAISED FLOOR) BURIED CONDUIT WIRING (UNDERGROUND OR IN FLOOR SLAB) FLEXIBLE METAL CONDUIT E EMERGENCY POWER CIRCUIT BRANCH CIRCUIT WIRING SHOWING HOME RUN TO 2G3-1/1,3,5] PANELBOARD/CIRCUITS INDICATED. (CONDUIT AND CONDUCTOR SIZE INDICATED WHEN LARGER N, THAN 3/4H SHM RK'S #12AND INDI ATE NUMB RTI OFWIRESWHEN MORE THAN 3 (PHASE/NEUTRAL/GROUND) NEUTRAL WIRE CODE -SIZED EQUIPMENT GROUND ISOLATED GROUND (GREEN W/ YELLOW TRACE) CONDUIT TURNS DOWN --O CONDUIT TURNS UP SYM CONDUIT ONLY C.O. REVISION BY PLAN SYM3OLS: POWER RECEPTACLES DUPLEX, 2 POLE, 3 WIRE, STRAIGHT BLADE, NEMA GROUNDING RECEPTACLE, 20 AMP, 120V, HUBBELL 5362 FOUR PLEX,(2) 2 POLE, 3 WIRE , STRAIGHT BLADE, NEMA GROUNDING RECEPTACLE (2) 20A, 120V, HUBBELL 5362 gc DUPLEX, 2 POLE, 3 WIRE, STRAIGHT BLADE, NEMA GROUNDING DROP RECEPTACLE, 20 AMP, 120V, HUBBELL 5362 FOUR PLEX, (2) 2 POLE, 3 WIRE , STRAIGHT BLADE, NEMA GROUNDING DROP RECEPTACLE (2) 20A, 120V, HUBBELL 5362 DUPLEX, 2 POLE, 3 WIRE, PARALLEL BLADE, ISOLATED GROUNDING RECEPTACLE, 20 AMP, 120V, HUBBELL IG5362 IG IG 20 1-0- SINGLE, 2 POLE, 3 WIRE, TWISTLOCK, ISOLATED GROUND RECEPTACLE, 120V, 20 AMP, HUBBELL IG -2310A IG 30 1-0- SINGLE, 2 POLE, 3 WIRE, TWISTLOCK, ISOLATED GROUND RECEPTACLE, 120V,30AMP HUBBELL IG -2610A F30 SINGLE, 2 POLE, 3 WIRE, TWISTLOCK, GROUNDING TYPE RECEPTACLE 120V, 30AMP, HUBBELL 2610A SINGLE, 3 POLE, 2 WIRE, EXPLOSION Ingc PROOF RECEPTACLE, 120V, 20AMP CROUSE HINDS #CPS152-202 20 20 HO - 30 20 132130 1050 20 208V,10, 2 POLE, 3 WIRE, TWISTLOCK SINGLE RECEPTACLE, NEMA L6-20. HUBBELL 2320A 208V,195, 2 POLE, 3 WIRE, TWISTLOCK SINGLE RECEPTACLE, NEMA L6-30. HUBBELL 2620A 208V,195, 2 POLE, 3 WIRE, TWISTLOCK SINGLE RECEPTACLE, NEMA L6-20. HUBBELL 2320A 120/208V-3 POLE, 4 WIRE, SINGLE RECEPTACLE GROUNDING, NEMA -14-30R. SIZE NOTED HUBBELL 9430A 120/208V-3 POLE, 4 WIRE, TWISTLOCK, SINGLE RECEPTACLE GROUNDING. SIZE NOTED HUBBELL CS6369 208V, 3 POLE, 4 WIRE, SINGLE DROP RECEPTACLE, GROUNDING, NEMA L15 -20R, SIZE NOTED. HUBBELL 2420A 208V-4 POLE, 4 WIRE, SINGLE RECEPTACLE 1'330 GROUND THRU SHELL, SIZE NOTED CROUSE -HINDS ARE3412 208V-4 POLE, 4 WIRE, SINGLE DROP RECEPTACLE 030 GROUND THRU SHELL, SIZE NOTED CROUSE -HINDS APR3453 o 208V, 3 POLE, 4 WIRE, SINGLE RECEPTACLE 60 GROUND THRU EXTRA POLE, SIZE NOTED. CROUSE -HINDS AREA6424 X30 1E060 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 30 AMP, CROUSE -HINDS ARE3422 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 60 AMP, CROUSE -HINDS AREA6424 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 100 100 AMP, CROUSE -HINDS AREA10425 480 VAC, 4 POLE, 3 WIRE RECEPTACLE IA (GROUND THRU EXTRA POLE & SHELL) 200 200 AMP, CROUSE -HINDS AREA20426 COMMUNICATIONS SINGLE JACK WALL OUTLET, WITH SINGLE GANG BACKBOARD, UNLESS UNLESS OTHERWISE NOTED. VOLUME CONTROL SPEAKER, CEILING MOUNTED D4 LOWBAY SPEAKER, HORN TYPE OTHERWISE NOTED. MOUNT AT 54" AFF MID HEIGHT SPEAKER, HORN TYPE CLUSTER HORNS APPROVED DATE SYM REVISION LIGHTING 0 HIGH INTENSITY DISCHARGE (HID) FIXTURE FO 0-0 FLOODLIGHT - WALL MTD. / POLE MTD. LIGHTING FIXTURE - 2' X 4' LAY -IN FLUORESCENT WITH 3 LAMPS LIGHTING FIXTURE - 2' X 4' LAY -IN FLUORESCENT WITH 2 LAMPS M LIGHTING FIXTURE - 2' X 2' LAY -IN FLUORESCENT WITH 2 LAMPS LIGHTING FIXTURE - 4' SURFACE OR PENDANT FLUORESCENT WITH 2 LAMPS O LIGHTING FIXTURE - RECESSED OR CANISTER LIGHTING FIXTURE - RECESSED FLUORESCENT WALL WASHING OPEN SIDE INIDCATES DIRECTION OF LIGHT LIGHT FIXTURE TAP 1/2" FLEXIBLE METAL CONDUIT - 3 #12: ONE PHASE CONDUCTOR, ONE NEUTRAL, ONE GROUND (3 #12 FOR SINGLE OR COMMON BALLAST SWITCHING) LIGHTING FIXTURE -8' PENDANT FLUORESCENT (2 - 4' TANDEM FIXTURES WITH 4 LAMPS TOTAL) NIGHT LIGHTING FIXTURE ON EMERG. SYST.- 1' X 2' NIGHT LIGHTING FIXTURE ON EMERG. SYST.- 4' LONG NIGHT LIGHTING FIXTURE ON EMERG. SYST.- 8' LONG NIGHT LIGHTING FIXTURE ON EMERG. SYST.- 2' X 2' NIGHT LIGHTING FIXTURE ON EMERG. SYST.- 2' X 4' O **Oak 4* I-01 EXIT SIGN, WALL MOUNTED (ARROW SHOWS DIRECTION OF LIGHTED ARROW) 1 EXIT SIGN, CEILING MOUNTED (ARROW SHOWS DIRECTION OF LIGHTED ARROW) F-01 EXIT SIGN, WALL MOUNTED WITH BATTERY BACKUP (ARROW SHOWS DIRECTION OF LIGHTED ARROW) '.1 EXIT SIGN, CEILING MOUNTED WITH BATTERY BACKUP (ARROW SHOWS DIRECTION OF LIGHTED ARROW) os $a $3 $4 $LV FIXTURE IDENTIFICATION "X" DENOTES FIXTURE TYPE "Y" DENOTES FIXTURE WATTAGE (INCL. BALLAST) REFER TO SHEET E500 FOR FIXTURE SCHEDULE OCCUPANCY SENSOR - CEILING MOUNTED UON LIGHT SWITCH - LOWER CASE INDICATES ASSOCIATED FIXTURES 3 - 3 -WAY 4 - 4 -WAY LV - LOW VOLTAGE SWITCH FIRE DETECTION — FA — FIRE ALARM SYSTEM RACEWAY ❑F 4 FIRE ALARM HORN ® SMOKE DETECTOR THERMAL DETECTOR FIRE ALARM PULL STATION EMERGENCY POWER OFF (E.P.O.) PUSHBUTTON EPO BY APPROVED DATE — TANKER BOOM ASSEMBLY — RECORD DRAWING 16735 HGI SEL 07.12.13 A P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 E-19 400 A 3 PH, 4 W 800 AF 600 AT LSIG T1 SINGLE LINE 480V OR 480Y/277V PANELBOARD (RATINGS AS INDICATED ON PANEL SCHEDULES) 208V OR 208Y/120V PANELBOARD (RATINGS AS INDICATED ON PANEL SCHEDULES) DRAWOUT-TYPE CIRCUIT BREAKER W/ ELECTRICAL OPERATOR L = LONG T.D. TRIP UNIT S = SHORT T.D. TRIP UNIT I = INSTANT. TRIP UNIT G = GND. FAULT TRIP UNIT , TRANSFORMER (DASHED LINE 30kVA INDICATES ELECTROSTATIC SHIELD) 208Y/120 V SA SURGE ARRESTER 0 0-• 12 kV 3A COMBINATION STARTER: CONTROLLER OR MCC CUBICLE NUMBER T XXA OR i‘ _L_ z 0 0 Ct U w w w z O < z ca ca STARTER SIZE THERMAL OVERLOADS (3) DIAGRAM SYMBOLS: b SINGLE LINE ATS Di100 100 ELECTRICAL POWER FILTER FUSED SWITCH DISCONNECT SWITCH AC GENERATOR DC GENERATOR AUTOMATIC TRANSFER SWITCH DISCONNECT SWITCH SWITCH RATING/FUSE RATING NF = NON FUSED INTERLOCK Ir K = KEY M = MECHANICAL E = ELECTRICAL 100A/3P ENCLOSED CIRCUIT BREAKER 480:120V -3E--iiji-• CURRENT TRANSFORMER, RATIO AS NOTED. (3) (3) AND QTY. AS NOTED POWER FACTOR CORRECTION CAPACITOR (REQUIRED ON 75 HP AND LARGER) FEEDER NUMBER MOTOR HORSEPOWER u 13 2500/5 CONTROL POWER TRANSFORMER, 480V-10 (3) PRIMARY 120V-10 SECONDARY. SIZE TO BE COORDINATED WITH DIGITAL METERING CREQUIREMENTS. SCHEMATIC (CONT.) RELAYS & COILS * =TYPE M = MOTOR STARTER CR = CONTROL RELAY C = CONTACTOR TR = TIME DELAY OR TIMING ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. N.O. CONTACT N.C. CONTACT N.O. ON DELAY CONTACT N.C. ON DELAY CONTACT N.O. OFF DELAY CONTACT N.C. OFF DELAY CONTACT DATE AF AFF AHC AHU AL AT ATS AWG CB CMCS CO CRU DED DP EF EMCS EMT EPO ES EWC FACP FAR FT FDP FVN R FVR GFI GND HP IMC kcmil DRAWN C. CLEVER 800AF 800AT —o o— OFF ON —0 0— R ELAY �o- -oa-Q --oma-�o— ABBREVIATIONS: SCHEMATIC DISCONNECT SWITCH FUSE MOLDED CASE CIRCUIT BREAKER FRAME RATING/TRIP RATING CONTROL POWER TRANSFORMER GROUND CONNECTION PILOT LIGHT * INDICATES COLOR PUSHBUTTON MOMENTARY CONTACT NORMALLY OPEN PUSHBUTTON MOMENTARY CONTACT NORMALLY CLOSED SELECTOR SWITCH MAINTAINED CONTACT TWO POSITION SELECTOR SWITCH MAINTAINED CONTACT THREE POSITION SOLENOID VALVE PRESSURE SWITCH - N.C. OPENS ON RISING PRESSURE PRESSURE SWITCH - N.O. CLOSES ON RISING PRESSURE FLOAT OR LEVEL SWITCH - N.C. OPENS ON RISING LEVEL FLOAT OR LEVEL SWITCH - N.O. CLOSES ON RISING LEVEL FLOW SWITCH - N.C. OPENS ON INCREASE IN FLOW FLOW SWITCH - N.O. CLOSES ON INCREASE IN FLOW TEMPERATURE SWITCH - N.C. OPENS ON RISING TEMP TEMPERATURE SWITCH - N.O. CLOSES ON RISING TEMP LIMIT SWITCH - N.C. LIMIT SWITCH - N.O. FRAME RATING IN AMPS ABOVE FINISHED FLOOR ABOVE HUNG CEILING AIR HANDLING UNIT ALUMINUM TRIP RATING IN AMPS AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE CIRCUIT BREAKER CENTRAL MANAGEMENT CONTROL SYSTEM CONDUIT ONLY COMPUTER ROOM UNIT DEDICATED DISTRIBUTION PANELBOARD EXHAUST FAN ENERGY MANAGEMENT CONTROL SYSTEM ELECTRICAL METALLIC TUBING EMERGENCY POWER OFF EPO SWITCH ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL FIRE ALARM RELAY FAN TERMINAL UNIT FIRE DETECTION PANEL FULL VOLTAGE, NON -REVERSING FULL VOLTAGE, REVERSING GROUND FAULT INTERRUPTER GROUND HORSEPOWER INTERMEDIATE METAL CONDUIT THOUSAND CIRCULAR MILS DATE 04.08.11 CHECKED ENGINEER J. HOUSEL CHECKED APPROVED APPROVED SUBTITLE LV M.BKR. MCC MCM MLO NACB NEC N/A NC NO PA PH PNL PVC RF RGS RVNR SRP SWBD SWGR SF ST TBD TD THHN THWN T/S UH UON VFD VSD WP XFMR GENERAL NOTES: 1. ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND HVAC DRAWINGS FOR GUIDANCE ON DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES, STRUCTURAL AND ARCHITECTURAL DETAILS, LOCATION OF DUCTS, PIPES AND STRUCTURAL STEEL, INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH DUCTS, PIPES, STRUCTURAL STEEL OR OTHER SYSTEMS. LOCATE LIGHTING SYMMETRICALLY IN PROPER RELATION TO FINISHED AREAS EXCEPT WHERE DIMENSIONED ON THE DRAWINGS OR LOCATED ON RELECTED CEILING PLANS. 2. PROVIDE ADDITIONAL SUPPORTS FOR SWITCHES, STARTERS, RACEWAYS AND OTHER ELECTRICAL EQUIPMENT WHERE THE BUILDING STRUCTURE IS NOT SUITABLE FOR DIRECT MOUNTING. 3. A NUMERAL BESIDE A BRANCH CIRCUIT OUTLET ON WIRING PLANS INDICATES PANELBOARD BRANCH CIRCUIT CONNECTION AND A LOWER CASE LETTER DESIGNATES PHASE. AN UPPER CASE LETTER BESIDE AN OUTLET INDICATES THE SWITCH LEG CONNECTION WHERE OUTLETS ARE LOCALLY SWITCHED. 4. SYMBOLS IN THE LEGENDS ARE APPLICABLE GENERALLY. FOR EXACT REQUIREMENTS REFER TO THE SCHEDULES, LAYOUTS, DETAILS AND SPECIFICATIONS SINCE THE APPEARANCE OF A PARTICULAR SYMBOLS IN THE LEGEND DOES NOT NECESSARILY IMPLY THAT THE ITEM IS INCLUDED IN THE CONTRACT. 5. CONNECT BRANCH CIRCUIT NEUTRAL TO RECEPTACLE TERMINAL BY MEANS OF A SHORT "PIGTAIL" PERMANENTLY SPLICED TO THE NEUTRAL. 6. MOUNT GROUPED DEVICES IN A SINGLE CONTINUOUS GANG BOX. USE PARTITIONS WHERE VOLTAGE BETWEEN EXPOSED LIVE PARTS OF ADJACENT SWITCHES MAY EXCEED 300 VOLTS. 7. VERIFY CEILING SUSPENSION SYSTEMS IN THE VARIOUS AREAS AND PROVIDE THE PROPER MOUNTING ACCESSORIES, TRIMS, ETC. TO SUIT THE PARTICULAR AREA. 8. CONDUITS WHICH ARE EXPOSED ON WALL SURFACES SHALL BE ARRANGED SUCH AS TO MINIMIZE ROUTING BETWEEN 2'-0" AFF AND 8'-0" AFF. CONDUITS WHICH MUST ENTER THIS SPACE TO FEED OUTLETS OR EQUIPMENT SHALL BE COMBINED IN MULTIPLE RUNS WITH A COMMON SUPPORT. 9. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL HAVE U.L. LISTED AND ENGINEER APPROVED EXPANSION FITTING. 10. ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE APPROVED BY UNDERWRITERS LABORATORIES INC. (UL) FOR THE PURPOSE FOR WHICH THEY ARE USED AND SHALL BEAR THEIR LABEL. 11. ALL ELECTRICAL INDUSTRIAL CONTROL PANELS SHALL BEAR THE LABEL OF A UL 508A APPROVED PANEL SHOP. 12. ALL ELECTRICAL EQUIPMENT AND RACEWAY SHALL BE SUPPORTED/ ANCHORED/ BRACED TO MEET ALL IMPOSED GRAVITY, WIND AND/OR SEISMIC FORCES IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT INTERNATIONAL BUILDING CODE. SEE STRUCTURAL DRAWINGS FOR SITE SPECIFIC WIND/SEISMIC DESIGN CRITERIA. WHERE THE DESIGN OF THESE SUPPORT SYSTEMS ARE NOT PROVIDED AS PART OF THESE ENGINEERING DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THIS DESIGN AND SHALL PROVIDE MANUFACTURERS DATA OR CALCULATIONS PREPARED BY A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON VERIFYING COMPLIANCE WITH THESE REQUIREMENTS. LOW VOLTAGE MAIN BREAKER MOTOR CONTROL CENTER THOUSAND CIRCULAR MILS MAIN LUGS ONLY NON -AUTOMATIC CIRCUIT BREAKER NATIONAL ELECTRICAL CODE NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN PAGING SYSTEM PHASE PANEL POLY -VINYL CHLORIDE (CONDUIT) RETURN FAN RIGID GALVANIZED STEEL REDUCED VOLTAGE, NON -REVERSING SMOKE REMOVAL PANEL SWITCHBOARD SWITCHGEAR SUPPLY FAN SHUNT TRIP (CIRCUIT BREAKER) TO BE DETERMINED TIME DELAY WIRE INSULATION TYPE WIRE INSULATION TYPE TWISTED & SHIELDED UNIT HEATER UNLESS OTHERWISE NOTED VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE WEATHER PROTECTED TRANSFORMER REFER TO N.E.C. REFER TO N.E.C. ISSUE FOR CONSTRUCTION AUGUST 24, 2017 ELECTRICAL LEGEND REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWWJILA PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB N0. 171-062 CURRENT REVISION 33615-10 SYMBOL A DATE 08.24.17 04.08.11 TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 THOMPSON, WA SHEET El JOB NO. 11347785 COMP NO. DWG NO. 14-01-E1 0 I 4 tion Center\_Drawings\ P8 Product Integr 0 I 4. 71-062 RA I:\ES\Projects co N CO 13.8 KV FEEDERS TO XFMR T3 FEEDER Y FEEDER X r-� r L 100E 600 A DOUBLE LOAD BREAK TK1 111-1 T2 1500/2000 KVA Z = 5.99% 480Y/277V N.C. 3200 AF 2400 AT M1 (EXISTING IQ DATA PLUS) 13.8 KV FEEDER Y 13.8 KV FEEDERS FEEDER X FROM XFMR T1 (2)4"C, 3 #4/0 (15 KV)(TYP) AMPS X/R 30 2704 4.57 L -G 2634 4.53 480 V - TIE BREAKER CLOSED AMPS X/R 30 34048 5.99 L -G 39849 6.31 FRONT VIEW - NOT TO SCALE UNIT SUBSTATION T2 PRIMARY FUSES = 3200AF = WESTINGHOUSE DS -632 1600AF = WESTINGHOUSE DS -416 3000AF = WESTINGHOUSE DB -75 (TIE BREAKER) 480 V UNIT SUBSTATION T1 /T2 BUS 'A' 480 V, 3200 A, 3 PH, 4 WIRE (50,000 AIC) (EACH BUS) T T1-T2/TIE Ti /B9 1 J SUBSTATION BREAKER SLI IINGS - WESTINGHOUSE AMPTECTOR I BREAKER SENSOR BREAKER SEIIINGS METERS LONG P.U. LONG DELAY SHORT P.U. SHORT DELAY G.F. P.U. G.F. DELAY MAIN * 2400A T2/A1 T2/A4 6s HV SWITCH HV SWITCH TRANSFORMER .50s Al * 800A 12x .75 FEEDER Y FEEDER X .18s T2/MAIN .22s A2 800A 12x T2/A2 T2/A5 8x .18s D (500A) .22s A3 800A 12x T2/A3 T2/A6 FRONT VIEW - NOT TO SCALE UNIT SUBSTATION T2 PRIMARY FUSES = 3200AF = WESTINGHOUSE DS -632 1600AF = WESTINGHOUSE DS -416 3000AF = WESTINGHOUSE DB -75 (TIE BREAKER) 480 V UNIT SUBSTATION T1 /T2 BUS 'A' 480 V, 3200 A, 3 PH, 4 WIRE (50,000 AIC) (EACH BUS) T T1-T2/TIE Ti /B9 1 J SUBSTATION BREAKER SLI IINGS - WESTINGHOUSE AMPTECTOR I BREAKER SENSOR BREAKER SEIIINGS INST. P.U. LONG P.U. LONG DELAY SHORT P.U. SHORT DELAY G.F. P.U. G.F. DELAY MAIN * 2400A N/A 1.0 6s 5x .5s D (950A) .50s Al * 800A 12x .75 12s 8x .18s D (500A) .22s A2 800A 12x 1.0 12s 8x .18s D (500A) .22s A3 800A 12x 1.0 12s 8x .18s D (500A) .22s A4 800A 12x .50 12s 8x .18s D (500A) .22s A5 800A 12x 1.0 12s 8x .18s D (500A) .22s A6 TIE 2000A N/A 0.9 4s 4x .33s C (760A) .35s * SET BY TEST, NON -CALIBRATED SEIIING USED 3000 AF 2000 AT n� __ SEE SHEET E4d FOR BUS B (T1) Al 1600 AF �\ 600 AT �J v (1) 0800A WIRE MCC 4B15 600 A M.L.O. 3 PH, 3 W SEE SHEET E4E A2 1600 AF 800 AT �J (1) WIRE 800A A3 1600 AF 800 AT (1) WIRE 4015.4 800 A M.L.O. 3 PH, 3 W SPARE NON-FUSED 200A 75 KVA 208Y/120 V 225A 1713 CC18 225 A M. BKR. 3 PH, 4 W TLC LIGHTING A4 1600 AF �\ 400 AT �/ (1) E WIRE CC14 225 A M. BKR. 3 PH, 4 W TLC LIGHTING AS 1\ 1600 AF 800 AT �J (1)E WIRE 01J75KVA 208Y/120 V 400A1-17 N.F. _on,y1225 KVA 208Y/120 V 4615 800 A M.L.O. 3 PH, 4 W 4B14-1 700 A M. BKR. 3 PH, 5 W 4B14-2 100A M. BKR. 3 PH, 5 W A6 SPACE _44.-u6.--�--225KVA 208Y/120 V 3013-1 150 A M. BKR. 3PH.5W 3014-1 150 A M. BKR. 3 PH. 5 W 3015.4-1 150 A M. BKR. 3 PH, 5 W 2C13-1 150 A M. BKR. 3 PH. 5 W 2C14-1 150 A M. BKR. 3 PH. 5 W 2015.4-1 150 A M. BKR. 3 PH, 5 W 4B16-4 700 A M. BKR. 3PH.5W 3C17-1 150 A M. BKR. 3 PH, 5 W 1B13-2 150 A M. BKR. 3 PH, 5 W 1B13-1 225 A M. BKR. 3 PH, 5 W FOOD PLAZA 1013-1 150 A M. BKR. 3 PH, 5 W 3016.2-1 150 A M. BKR. 3 PH, 5 W 2017-1 150 A M. BKR. 3 PH, 5 W 2016.2-1 150 A M. BKR. 3 PH, 5 W (N.C.) 2000A I-' 400A N.F. ------ 225 KVA �h 208Y/120 V LEGEND 13.8KV AMPS X/R 30 2752 4.82 L -G 2687 4.73 VOLTAGE FOR FAULT CALCULATION FAULT CALCULATION VALUES REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND is M1 KEY INTERLOCK WESTINGHOUSE IQ DATA PLUS II MONITORING AND PROTECTION UNIT FEEDER TYPE DESIGNATION - REFER TO SINGLE LINE DIAGRAM SHEET E4 FOR FEEDER SCHEDULES GENERAL NOTES UNDER NORMAL CONDITIONS, SUBSTATION OPERATES WITH TIE BREAKER CLOSED AND MAIN BREAKER FOR BUS A (TRANSFORMER T2) CLOSED. ONE OF THE MEDIUM VOLTAGE SWITCHES FOR T2 WILL NORMALLY BE CLOSED. CONSTRUCTION NOTES DISCONNECT AND REMOVE (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 1,3,5, (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 25,27,29, AND (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 26,28,30. RETURN CIRCUIT BREAKER TO BOEING. DISCONNECT AND REMOVE (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 13,15,17, (1) 20A/2P CIRCUIT BREAKER FROM POSITIONS 19, 21 AND (1) 20A/3P CIRCUIT BREAKER FROM POSITITONS 26,28,30. RETURN CIRCUIT BREAKERS TO BOEING. 4B18-1 700 A M. BKR. 3 PH, 5 W 4B18-2 100A M. BKR. 3 PH, 5 W 3018.2-1 150 A M. BKR. 3 PH, 5 W 2015.2-1 150 A M. BKR. 3 PH, 5 W REMOVAL 1017-1 150 A M. BKR. 3 PH, 5 W 1C18.4-1 150 A M. BKR. 3 PH, 5 W ISSUE FOR CONSTRUCTION AUGUST 24, 2017 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA A 1 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB N0. 171-062 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RECORD DRAWING (FDS) RH JK 3/31/95 B UPDATE PER SITE VISIT J# 981051 KR KR 1/5/99 C AS-FOUND/TESTED(DRAWING # WAS E4C) MAINT RMA/MN 1-23-11 D 4C15-4 PHASE 2B HIGH BAY RENOVATION 11347785 HGI SEL 01.31.12 E P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 d� 35276 D'�'� �'I STERE SSIONAL� c ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R. HAMMETT DATE CHECKED J. BITTINGER SUBTITLE ONE -LINE DIAGRAM UNIT SUBSTATION T2 CURRENT REVISION SYMBOL - DATE 33615-10 08.24.17 VED BY DEPT. DATE ENGINEER R. HAMMETT CHECKED R. HAMMETT APPROVED J. KOKOCZKA 7/25/94 APPROVED TITLE ELECTRICAL MASTER BUILDING 14-01 THOMPSON SITE SHEET E4ST2R JOB NO. 981051 COMP NO. DWG NO. 14-01-E4ST2R OTTFNft 05/77/13 08.52 0 0 t Integration Center\_Drawings\14-01- 0 O I 4 0) U N L. 0 w 0 1- 0 r) tO 0 N SYM 12.E RISER 13.2 13.1 1V/ 15.E 13B12 1C15.2-1/38 RRIDO 12B12 3 `BREAK R14 118B1 1C15.2-1/38 U LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND REFER TO SHEET E501 FOR FIXTURE SCHEDULE �v LOW VOLTAGE SWITCH WITH 1/2"C,3/C#14 TO RESPECTIVE RELAY IN LIGHTING CONTROL PANEL, UNLESS OTHERWISE NOTED. $M "MASTER" FIXTURE WITH PREWIRED 9 FT. FLEXIBLE INTERCONNECTION CABLE TO EACH OF ONE OR TWO "SLAVE" FIXTURES. CEILING MOUNTED MOTION DETECTOR, INSIGHT #OS—C CEILING MOUNTED POWER PACK, INSIGHT #OSPS-20A- 277 WALL MOUNT MOTION SENSOR, INSIGHT #IS3-1 KVA-277 GENERAL NOTES: 1. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. R94B1 1C13 —1 /40 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER w � -J w = cn Qw Ci) 1C16-1(REF) 1C13-1 (REF) REVISION R14 LCP-1C16-1/3/3R7, MATCH LINE SEE SHEET 1E14 R8,R9,R10,R11,R12,R13,R14 15B15 TRA ON 8 1C14-1 (REF) BY APPROVED DATE SYM REVISION BY LIGHTING PARTIAL PLAN - REMOVAL SCALE: 1/8" = 1'-0" APPROVED DATE CAD CONVERSION CADDNW 04.21.98 A MODIFY OFFICE FOR B-NN14 J#993098-00 BOYE 09.23.99 B REWIRE LIGHTS TO EMERG. POWER 088818-00 DE LARSON CAS 03.28.01 C P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 u 1C15.2-1 (REF) REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED P DRAWN DATE CHECKED ENGINEER CHECKED APPROVED SUBTITLE TITLE 1C15. —1 /38 1/2"C,(2)3/C#14 TO LCP-1 C16-1 /R3,R4 LCP-1 C16-1(REF) 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. EMERGENCY LIGHTING CIRCUITS: 2#10 UNLESS OTHERWISE NOTED. 7. REFER TO SHEETS E505, E513, E514 AND E515 FOR LIGHTING CONTROL DIAGRAMS AND SCHEDULES. DEMOLITION NOTES: DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE AND ASSOCIATED WIRING DEVICES. RETURN FIXTURE TO BOEING. DISCONNECT AND REMOVE WIRING FROM LOW VOLTAGE SWITCH TO RELAY #6 IN LOW VOLTAGE LIGHTING CONTROL PANEL LCP-1C16-1. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION AUGUST 24, 2017 ELECTRICAL MASTER LIGHTING PARTIAL PLAN P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. B—C/12.4-16 1 RECEIVED CITY OF TU'1LA PEBIJIIT CENTER 8' SCALE: 1/8"=1' 16' THOMPSON, WA CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 CURRENT REVISION 33615-10 SYMBOL DATE 08.24.17 SHEET IEIIAR JOB NO. COMP NO. DWG NO. 14-01-1E11AR 11 •(11.7(1 AM 12 /27 /2010 a c cs z T __7-1 1E10A 1E1OB 1E11A 1E11B 1E12 1E13 1E14 1E15 -H 1E16 1E17 1E18 1t9 RECEIVED CITY OF TU'1LA PEBIJIIT CENTER 8' SCALE: 1/8"=1' 16' THOMPSON, WA CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 CURRENT REVISION 33615-10 SYMBOL DATE 08.24.17 SHEET IEIIAR JOB NO. COMP NO. DWG NO. 14-01-1E11AR 11 •(11.7(1 AM 12 /27 /2010 a c cs z DEMOLITION NOTES: FIELD VERIFY IF THIS JUNCTION BOX AND ITS ASSOCIATED CIRCUITING EXISTS. IF SO, REMOVE CONDUCTORS BACK TO SOURCE AND CAP JUNCTION BOX. REMOVE POWER POLES, CONDUITS, AND CONDUCTORS BACK TO SOURCE JUNCTION BOX. DISCONNECT AND REMOVE EXISTING FLOORBOX AND ITS ASSOCIATED WIRING BACK TO ITS POWER SOURCE. DISCONNECT AND REMOVE EXISTING RECEPTACLE AND ITS ASSOCIATED WIRING BACK TO ITS POWER SOURCE. EXISTING RECEPTACLE TO BE RECIRCUITED. DISCONNECT AND REMOVE CONDUITS AND CONDUCTORS. 6 DISCONNECT AND REMOVE (1)20A/3P CIRCUIT BREAKER FROM POSITIONS 13,15,17, AND 26,28,30, (1)20A/2P CIRCUIT BREAKER FROM POSITIONS 19, 21. RETURN CIRCUIT BREAKERS TO BOEING. REMOVE CONDUIT AND CONDUCTORS. >DISCONNECT AND REMOVE (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 1,3,5, (1) 20A/3P FROM POSITIONS 25,27,29 AND (1) 20A/3P CIRCUIT BREAKER FROM POSITIONS 26,28,30. RETURN CIRCUIT BREAKER TO BOEING. DISCONNECT AND REMOVE EXISTING DUPLEX RECEPTACLE EXISTING CIRCUIT TO REMAIN. P8 Product Integration Center\_Drawings\14-01-1E61AR.DWG I:\ES\Projects\17\171-062 RA 14-01 SYM 12.E FIRE RISER CHASE 13B12 1C13-1/26 rF, 26 WP 13.E 1 /l 1/1.4 152 SURFACE MTD. DISC. SWITCH MTD. ADJACENT TO VFW ABOVE CEILING (TIP) 42 CORRIDOR (12B12 1C13-1/42---- 39,41 cD w I J 1E61 E521 OPEN OFFICE 13B14 WOMENS OPEN FFICE V-125 /6H,P 14B13 TIBULE 7 GFI 9 GFI 1C13-1/7,9,11 11 GFI 17 HWH-11 5 1;5KW GFIJ NITOR P' 1C15.2 ( C15.2 MUTED 39 1C14-1/7, 1C14-1/1, 1C13-1/30 24 1C13-1/24 13-1 1C14-1/2,4,6 37 15B15 1C13-1/13,15,17 1C13-1/19,21 REVISION BY APPROVED DATE A CAD CONVERSION CADDNW 04.22.98 1C14-1/38 SYSTEM FURNITURE POWER SOURCE SCHEDULE 1C14-1/32,34,36 J—BOX REF. NO. PANEL NO. RECEPTACLES a PHASE b PHASE c PHASE CKT. NO. TYPE CKT. NO. TYPE CKT. NO. TYPE (1) 1C13-1 1 STD 3 STD 5 STD 14 1C14-1 20 'S 8 4 24 "01 fi/9/8SYs 1C15.2-1 1 1:j)(/ g1 STD 5 STD 16 1C15.2-1 2 STD 4 STD 6 STD 17 1C15.2-1 7 STD 11 1C14-1 13 STD 15 STD 17 STD 12 1C14-1 14 STD SYM F REVISION MULTIPLE SITE P-6 FLAT SCREENS W1877415 B INSTALL POWER TO NEW WORKSTATION J#D93P0309 AA/JB BITTINGER 04.19.99 G UPDATE DLR/COFFMAN DESIGN TRANSPORTATION AISLE 1088 SYSTEM FURNITURE POWER SOURCE SCHEDULE J—BOX REF. PANEL NO. RECEPTACLES RECEPTACLES b PHASE a PHASE CKT. NO. b PHASE CKT. NO. c PHASE CKT. NO. TYPE 13 1C14-1 19 STD 21 7/1 23 STD 14 1C14-1 20 'S 8 4 24 "01 fi/9/8SYs 1C15.2-1 1 1:j)(/ g1 STD 5 STD 16 1C15.2-1 2 STD 4 STD 6 STD 17 1C15.2-1 7 STD 11 1C14-1 13 STD 15 STD 17 STD 12 1C14-1 14 STD 16 STD 18 STD 1C15.2-1/32 SYSTEM FURNITURE POWER SOURCE SCHEDULE 1C15.2-1/37 J—BOX REF. NO. PANEL NO. RECEPTACLES a PHASE b PHASE c PHASE CKT. NO. TYPE CKT. NO. TYPE CKT. NO. TYPE 13 1C14-1 19 STD 21 STD 23 STD 14 1C14-1 20 STD 22 STD 24 STD 15 1C15.2-1 1 STD 3 STD 5 STD 16 1C15.2-1 2 STD 4 STD 6 STD 17 1C15.2-1 7 STD 9 STD 11 STD 18 1C15.2-1 8 STD 10 STD 12 STD 208Y/120 VOLT 1ST FLOOR PARTIAL PLAN — SCALE: 1/8" = 1'-0" BY SAZAN/SL ESBROOK APPROVED DATE 06.26.13 11.05.13 C D E MODIFY OFFICE FOR B—NN14 SYSTEMS FURN MOD INSTALL A 120V RECEPTACLE J#993098 J#1000979003 WO#5111072 BOYE SSH HABTE CAS 09.23.99 11/19/03 H RECONFIG OFFICE FOR INDUSTRIAL ATHLETE J P-8 PRODUCT INTEGRATION CENTER W3676325 33615-10 D. OTTEN CASNE DLO MN 07.27.15 08.24.17 06.25.07 1 REMOVAL r T 1E60A 1E6OB 1E61A sF;: 1E61B 1E63 1E64 1E65 1E62 1E66 1E67 1E68 1E69 1C15.2-1/1,3,5 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED P"' WED BY DEPT. DATE DRAWN DATE CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE 16' SCALE: 1/8"=1'-0" RE CODE COMPLIANCE APPROVED LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND 23 J—BOX WITH 3/4"C, 8 #10 HOME RUN (3 PHASE, 3 NEUTRAL, 1 GROUND, 1 ISOLATED GROUND) FOR SYSTEM FURNITURE POWER POLE. 0 SYSTEM FURNITURE POWER POLE X INDICATES POINT OF SEPARATION BETWEEN POWER SOURCES IN SYSTEM FURNITURE Ep SMOKE DAMPER AND SMOKE DETECTOR AUXILIARY CONTACT. CONNECT PER DETAIL 3, SHEET E538 J—BOX INTERFACE WITH ELECTRIC DOOR RELEASE. SEE DETAIL 2, SHEET E538. ©DR GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) B 0CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND BLACK RED BLUE WHITE GREEN BROWN ORANGE YELLOW GRAY GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. Vending Machine 18 > Ice Machine 1 9 > Coffee Maker 110 > (2) Microwaves Stacked Refrigerator I -vv NOV 21 2017 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION AUGUST 24, 2017 208Y/120 VOLT 1ST FLOOR PARTIAL PLAN ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 RECEIVED CITY OF TUKWILA PERMIT CENTER CCASNE ENGINEERING, INC. THOMPSON, WA ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SU/7E 205 KIRKLAND, WA 98 . (425) 522-1000 1fllM'CdWGf01I JOB ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 98033 WWW.CASNE.COM NO. 171-062 CURRENT REVISION 33615-10 SYMBOL J DATE 08.24.17 SHEET IE6IAR JOB NO. COMP NO. DWG NO. 14-01-1 E61 AR 4-001—E505R.dwg ntegration Center\_Drawings\ 0 co 0 71-062 R co SYM 2 -LAMP BALLAST TO LIGHT FIXTURES) OCCUPANCY SENSOR BASIC OCCUPANCY CONTROL 2 -LAMP FIXTURE 1 -LAMP FIXTURE 2 -LAMP BALLAST ALTERNATE FIXTURE TYPES .- .• • • .• .• .• .• .• .• • .• .• .• TO ADDITIONAL FIXTURES ON SAME CIRCUITS 7R10 r E -N x LL J Q w o 01 CC X [1: LAMP (TYP) 7R9 2 FIXTURE MASTER/SLAVE CONFIGURATION 3 -LAMP BALLAST N 7R9 3 FIXTURE MASTER/SLAVE CONFIGURATION REVISION BY N APPROVED • DATE 0 LOW VOLTAGE RELAY - POWER TERMINALS (TYP) LOW VOLTAGE LIGHTING CONTROL PANEL, LCP 1C16-1 (TYPICAL CONTROL PANEL CALLOUT) 24 RELAY PANEL (48 RELAY PANEL SIMILAR) LOW VOLTAGE WIRING TERMINALS (TYP) O O R1 7R9 7R10 7R11 TYPICAL HOMERUN CALLOUT LCP 1C16-1/7/7R9,R10,R11 * 7 INDICATES NON -RELAY CONTROLLED CIRCUIT * 7R9,R10,R11 INDICATES CONTROL FROM RELAYS R9,R10 & R11 VIA CKT. 7 SYM 7 Eo O 0 0 O NEUTRAL R8 R9 R10 R11 R12 CIRCUIT 7 BLU 0oR BK Y W R BK Y W R BK Y W R BK Y W R BK Y W RBK Y W 0 R BK Y W o R BK Y W 0 R BK Y W R BK Y W iR B Y W R BK Y W o R BK Y W o0 R BK Y W o R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W o BLU W R BK W R BK 3 PROGRAMMABLE SYSTEM SWITCHES 5 W R BK 6 W R BK TYPICAL RELAY USAGE - SEE LIGHTING CONTROL SCHEDULES FOR ACTUAL ASSIGNMENTS H N G R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 LCP 3C15.4-2 ONLY - 1 loot X001 X061 loo( Too X001 0 0 0 0 7510 0 -071 0 PROGRAM CARDS LCP 1016-1 ONLY TIME "ON" "OFF" SIGNAL sc4' IN OUT SHLD 4 4 --- i --1 - LEGE\ D: (TYP) OFF LOW VOLTAGE WALL SWITCH LCP COMPONENTS (TYP) RTUB24 CABINET RINTER2424 INTERIOR W/RELAYS RPWR277 POWER SUPPLY RCOV24SHL COVER RRDC12 CARDS (2) RCC24 PANEL CONTROLLER CARD REVISION TO OUTDOOR PHOTOCELL ON NORTH CANOPY SEE SHEET E503 WHITE (COMMON) BLACK (OFF) RED (ON) LCP 109.2-1 LCP 1016-1 NETWORK INTERFACE (SEE DIAGRAM BELOW) 7>8 LOW VOLTAGE CONTROL WIRING (CLASS 2) TYPICAL CONTROL RUN CALLOUT LCP 1C16 -1/R7 1/2"C, 3/C #14 LCP 209-1 3/4"C, 2/0 #18 TWISTED LIGHTING CONTROL NETWORK CABLE (TYP) (G.E. RDWIRES-2S) BY APPROVED DATE co 0 in rn RECORD DRAWING (FDS) RH JK 03.31.95 P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 LCP 2015.4-2 LCP 309-1 a F- w z 480/277 V LIGHTING PANELBOARD. 1C16-1 (TYPICAL PANELBOARD CALLOUT) A B C REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND 1 ,--..r-.. 2 —0— —0 3.---, .-". 4 ---0— 1 —0 7.--. r. 8 —0 9 1 ,---. o cn —�11 r '-�. 1 0 w J w D C....) w 13 * '--� 14 C w � o � —015'-� r--.. 16 D zo s =cn —o-9— • r-.2 0 cD >- J w (-5w o i 23 ... --/'-'• 24 z>w �o� 25r. r-. 26 � J --0-- —O 2 —cam '^. 30 —031 �-0 —033 r-. '-. 34 --- 35'-x. 360 39 r-. '--` 40 041 r-. 420 POWER SOURCE FOR LIGHTING CONTROL PANEL - SEE PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBER 0 0 GE\HAL \OTES: PROVIDE LIGHTING CONTROL PANELS (LCP'S) WHERE INDICATED ON THE LIGHTING PLAN DRAWINGS. REFER TO MANUFACTURER'S INSTRUCTION LITERATURE FOR DETAILED INSTALLATION AND WIRING TERMINATION INFORMATION ON THE G.E. TLC LOW VOLTAGE LIGHTING CONTROL SYSTEM. CIRCUIT NUMBERS SHOWN FOR LIGHTING CONTROL PANEL AND LIGHTING PANELBOARD ARE FOR EXAMPLE ONLY. REFER TO PLAN DRAWINGS AND PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBERS. INSTALL WIRING BETWEEN ALL LIGHTING CONTROL PANEL RELAYS AND LIGHTING PANELBOARDS AS REQUIRED. LIGHTING CONTROL PANEL CONTROL BOARD AND ACCESSORY BOARDS TO PROVIDE CONTROL IN ACCORDANCE WITH THE SPECIFICATIONS. 6 > REFER TO SHEET E502 FOR ELEVATION VIEW OF THE LIGHTING CONTROL PANEL AND ASSOCIATED LIGHTING PANEL. CONTROL WIRING CALLOUT MAY NOT APPEAR ON PLAN DRAWINGS, BUT MUST BE INCLUDED FOR ALL LOW VOLTAGE SWITCHES SHOWN. 8 > LOW VOLTAGE CONTROL CIRCUITS FOR MORE THAN SET TO 50 fc / / SET TO 40 fc HI WHITE -1-0 22 BLUE ❑ 21 BLACK ❑ 14 RED ❑ 13 LIGHTING CONTROL NETWORK DIAGRAN LCP 3015.4-2 0 LO 2 ❑ 1 ❑ MULTIPOINT LC4P-PC1A CONTROLLER MOUNTED IN 4TH FLOOR ELECTRICAL VAULT SEE SHEET 4E11 BLACK — RED CEILING TILE MULTIPOINT PC1A DAYLIGHT SENSOR REFER TO PLAN DRAWINGS FOR LOCATION SEE SHEET 3E11 DAYLIGHT SENSOR DETAIL CONNECT TO HIGH BAY LIGHTING NETWORK IN EXISTING 4TH FLOOR TELEPHONE ROOM REFER TO SHEET E504 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN DATE CHECKED SUBTITLE ONE SWITCH MAY BE COMBINED IN COMMON CONDUITS WHERE FEASIBLE. IEfv OLITIO\ \OT -S DISCONNECT AND REMOVE WIRING FROM LIGHTING CONTROL PANEL TO EXISTING LOW VOLTAGE SWITCH IN OPEN OFFICE. SEE SHEET 1E11 AR FOR EXACT LOCATION. ISSUE FOR CONSTRUCTION AUGUST 24, 2017 DETAILS LIGHTING CONTROL DIAGRAM REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL A PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 CURRENT REVISION SYMBOL A DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE BUILDING 14-01 Eco LECTRICAL MASTER COL. B -E/6-19 THOMPSON, WA SHEET E505R JOB NO. COMP NO. DWG NO. 14-01-1505R 1 •n1.2n Am 12/97/min R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W R BK Y W o R BK Y W o R BK Y W R BK Y W R BK Y W R BK Y W W R BK W R BK 3 PROGRAMMABLE SYSTEM SWITCHES 5 W R BK 6 W R BK TYPICAL RELAY USAGE - SEE LIGHTING CONTROL SCHEDULES FOR ACTUAL ASSIGNMENTS H N G R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 LCP 3C15.4-2 ONLY - 1 loot X001 X061 loo( Too X001 0 0 0 0 7510 0 -071 0 PROGRAM CARDS LCP 1016-1 ONLY TIME "ON" "OFF" SIGNAL sc4' IN OUT SHLD 4 4 --- i --1 - LEGE\ D: (TYP) OFF LOW VOLTAGE WALL SWITCH LCP COMPONENTS (TYP) RTUB24 CABINET RINTER2424 INTERIOR W/RELAYS RPWR277 POWER SUPPLY RCOV24SHL COVER RRDC12 CARDS (2) RCC24 PANEL CONTROLLER CARD REVISION TO OUTDOOR PHOTOCELL ON NORTH CANOPY SEE SHEET E503 WHITE (COMMON) BLACK (OFF) RED (ON) LCP 109.2-1 LCP 1016-1 NETWORK INTERFACE (SEE DIAGRAM BELOW) 7>8 LOW VOLTAGE CONTROL WIRING (CLASS 2) TYPICAL CONTROL RUN CALLOUT LCP 1C16 -1/R7 1/2"C, 3/C #14 LCP 209-1 3/4"C, 2/0 #18 TWISTED LIGHTING CONTROL NETWORK CABLE (TYP) (G.E. RDWIRES-2S) BY APPROVED DATE co 0 in rn RECORD DRAWING (FDS) RH JK 03.31.95 P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 LCP 2015.4-2 LCP 309-1 a F- w z 480/277 V LIGHTING PANELBOARD. 1C16-1 (TYPICAL PANELBOARD CALLOUT) A B C REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND 1 ,--..r-.. 2 —0— —0 3.---, .-". 4 ---0— 1 —0 7.--. r. 8 —0 9 1 ,---. o cn —�11 r '-�. 1 0 w J w D C....) w 13 * '--� 14 C w � o � —015'-� r--.. 16 D zo s =cn —o-9— • r-.2 0 cD >- J w (-5w o i 23 ... --/'-'• 24 z>w �o� 25r. r-. 26 � J --0-- —O 2 —cam '^. 30 —031 �-0 —033 r-. '-. 34 --- 35'-x. 360 39 r-. '--` 40 041 r-. 420 POWER SOURCE FOR LIGHTING CONTROL PANEL - SEE PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBER 0 0 GE\HAL \OTES: PROVIDE LIGHTING CONTROL PANELS (LCP'S) WHERE INDICATED ON THE LIGHTING PLAN DRAWINGS. REFER TO MANUFACTURER'S INSTRUCTION LITERATURE FOR DETAILED INSTALLATION AND WIRING TERMINATION INFORMATION ON THE G.E. TLC LOW VOLTAGE LIGHTING CONTROL SYSTEM. CIRCUIT NUMBERS SHOWN FOR LIGHTING CONTROL PANEL AND LIGHTING PANELBOARD ARE FOR EXAMPLE ONLY. REFER TO PLAN DRAWINGS AND PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBERS. INSTALL WIRING BETWEEN ALL LIGHTING CONTROL PANEL RELAYS AND LIGHTING PANELBOARDS AS REQUIRED. LIGHTING CONTROL PANEL CONTROL BOARD AND ACCESSORY BOARDS TO PROVIDE CONTROL IN ACCORDANCE WITH THE SPECIFICATIONS. 6 > REFER TO SHEET E502 FOR ELEVATION VIEW OF THE LIGHTING CONTROL PANEL AND ASSOCIATED LIGHTING PANEL. CONTROL WIRING CALLOUT MAY NOT APPEAR ON PLAN DRAWINGS, BUT MUST BE INCLUDED FOR ALL LOW VOLTAGE SWITCHES SHOWN. 8 > LOW VOLTAGE CONTROL CIRCUITS FOR MORE THAN SET TO 50 fc / / SET TO 40 fc HI WHITE -1-0 22 BLUE ❑ 21 BLACK ❑ 14 RED ❑ 13 LIGHTING CONTROL NETWORK DIAGRAN LCP 3015.4-2 0 LO 2 ❑ 1 ❑ MULTIPOINT LC4P-PC1A CONTROLLER MOUNTED IN 4TH FLOOR ELECTRICAL VAULT SEE SHEET 4E11 BLACK — RED CEILING TILE MULTIPOINT PC1A DAYLIGHT SENSOR REFER TO PLAN DRAWINGS FOR LOCATION SEE SHEET 3E11 DAYLIGHT SENSOR DETAIL CONNECT TO HIGH BAY LIGHTING NETWORK IN EXISTING 4TH FLOOR TELEPHONE ROOM REFER TO SHEET E504 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN DATE CHECKED SUBTITLE ONE SWITCH MAY BE COMBINED IN COMMON CONDUITS WHERE FEASIBLE. IEfv OLITIO\ \OT -S DISCONNECT AND REMOVE WIRING FROM LIGHTING CONTROL PANEL TO EXISTING LOW VOLTAGE SWITCH IN OPEN OFFICE. SEE SHEET 1E11 AR FOR EXACT LOCATION. ISSUE FOR CONSTRUCTION AUGUST 24, 2017 DETAILS LIGHTING CONTROL DIAGRAM REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL A PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 CURRENT REVISION SYMBOL A DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE BUILDING 14-01 Eco LECTRICAL MASTER COL. B -E/6-19 THOMPSON, WA SHEET E505R JOB NO. COMP NO. DWG NO. 14-01-1505R 1 •n1.2n Am 12/97/min 4-01 —E4T2.dwg n Center\_Drawings\ 2 o 0 (0 0 In 0 0 0, w co M rri 60 io f0 N 13.8 KV FEEDERS TO XFMR T3 FEEDER Y FEEDER X -fl T L 600 A DOUBLE LOAD BREAK C L 100E T2 1500/2000 KVA --(4. Z = 5.99% 480Y/277V (N.C.) 3200 AF 2400 AT ) 13.8 KV FEEDER Y 113.8 KV FEEDERS FROM XFMR T1 FEEDER X (2)4"C, 3 #4/0 (15 KV)(TYP) AMPS X/R 30 2704 4.57 L -G 2634 4.53 480 V - TIE BREAKER CLOSED AMPS X/R 30 34048 5.99 L -G 39849 6.31 M1 (EXISTING IQ DATA PLUS) FRONT VIEW - NOT TO SCALE UNIT SUBSTATION T2 PRIMARY FUSES = 3200AF = WESTINGHOUSE DS -632 1600AF = WESTINGHOUSE DS -416 3000AF = WESTINGHOUSE DB -75 (TIE BREAKER) T T1-T2/TIE Ti /B 9 -1 J 480 V UNIT SUBSTATION T1 /T2 BUS 'A' 480 V, 3200 A, 3 PH, 4 WIRE (50,000 AIC) (EACH BUS) SUBSTATION BREAKER SETTINGS - WESTINGHOUSE AMPTECTOR I BREAKER SENSOR BREAKER SLIIINGS METERS LONG P.U. LONG DELAY SHORT P.U. SHORT DELAY G.F. P.U. G.F. DELAY MAIN * 2400A T2/A1 T2/A4 6s HV SWITCH HV SWITCH TRANSFORMER .50s Al * 800A 12x .75 FEEDER Y FEEDER X .18s T2/MAIN T2/A2 T2/A5 800A 12x 1.0 12s 8x .18s D (500A) T2/A3 T2/A6 FRONT VIEW - NOT TO SCALE UNIT SUBSTATION T2 PRIMARY FUSES = 3200AF = WESTINGHOUSE DS -632 1600AF = WESTINGHOUSE DS -416 3000AF = WESTINGHOUSE DB -75 (TIE BREAKER) T T1-T2/TIE Ti /B 9 -1 J 480 V UNIT SUBSTATION T1 /T2 BUS 'A' 480 V, 3200 A, 3 PH, 4 WIRE (50,000 AIC) (EACH BUS) SUBSTATION BREAKER SETTINGS - WESTINGHOUSE AMPTECTOR I BREAKER SENSOR BREAKER SLIIINGS INST. P.U. LONG P.U. LONG DELAY SHORT P.U. SHORT DELAY G.F. P.U. G.F. DELAY MAIN * 2400A N/A 1.0 6s 5x .5s D (950A) .50s Al * 800A 12x .75 12s 8x .18s D (500A) .22s A2 800A 12x 1.0 12s 8x .18s D (500A) .22s A3 800A 12x 1.0 12s 8x .18s D (500A) .22s A4 800A 12x .50 12s 8x .18s D (500A) .22s A5 800A 12x 1.0 12s 8x .18s D (500A) .22s A6 TIE 2000A N/A 0.9 4s 4x .33s C (760A) .35s * SET BY TEST, NON -CALIBRATED SEI IING USED SYM Al 1600 AF �\ 600 AT J (1) E 800A WIREWIRE MCC 4B15 600 A M.L.O. 3 PH, 3 W SEE SHEET E4E REVISION A2 1600 AF /1\\ 800 AT �J (1) WIRE 800A A3 1600 AF �\ 800 AT J (1) WIRE SPARE 4015.4 800 A M.L.O. 3 PH. 3 W rNON-FUSED I J 200A 75 KVA 208Y/120 V A B C D E RECORD DRAWING UPDATE PER SITE VISIT AS-FOUND/TESTED(DRAWING # WAS E4C) 4C15-4 PHASE 2B HIGH BAY RENOVATION P-8 PRODUCT INTEGRATION CENTER (FDS) J# 981051 MAINT 11347785 33615-10 BY RH KR RMA/MN HGI CASNE APPROVED 225A FCT31 A4 1600 AF �\ 400 AT J (1) WIRE A5 1600 AF �\ 800 AT J (1) 800A WIRE A6 ccs s 225 A M. BKR. 3 PH, 4 W TLC LIGHTING DATE SYM CC14 225 A M. BKR. 3 PH, 4 W TLC LIGHTING f(Y 75 KVA 208Y/120 V 4B16-2 225 A M. BKR. 3 PH, 4 W 400A N.F. A � 225 KVA -H, 208Y/120 V 4B14-1 700 A M. BKR. 3 PH. 5 W 4B15 800 A M.L.O. 3 PH, 4 W SPACE A 1-�.�„1.)- 225 KVA 208Y/120 V 4B14-2 100A M. BKR. 3 PH, 5 W 4B16-4 700 A M. BKR. 3 PH, 5 W 3013-1 150 A M. BKR. 3 PH, 5 W 1B13-2 150 A M. BKR. 3 PH, 5 W 1B13-1 225 A M. BKR. 3 PH, 5 W FOOD PLAZA REVISION BY 3014-1 150 A M. BKR. 3 PH, 5W 3015.4-1 150 A M. BKR. 3 PH. 5 W 3017-1 150 A M. BKR. 3 PH. 5 W 3016.2-1 150 A M. BKR. 3PH.5W 2013-1 150 A M. BKR. 3 PH, 5 W APPROVED 2014-1 150 A M. BKR. 3 PH, 5 W 2015.4-1 150 A M. BKR. 3PH.5W 2017-1 150 A M. BKR. 3PH.5W 2016.2-1 150 A M. BKR. 3 PH. 5 W 1013-1 150 A M. BKR. 3 PH, 5 W DATE JK KR SEL MN 3/31/95 1/5/99 1-23-11 01.31.12 08.24.17 1015.2-1 150 A M. BKR. 3 PH, 5 W ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED OVED BY DEPT. DATE DRAWN R. HAMMETT CHECKED J. BITTINGER R. HAMMETT CHECKED R. HAMMETT 3000 AF 2000 AT <F-�� (N.C.) 2000A SEE SHEET E4d FOR BUS B (T1) 400A N.F. A 225 KVA -Fa 208Y/120 V LEGEND 13.8KV AMPS X/R 30 2752 4.82 L -G 2687 4.73 VOLTAGE FOR FAULT CALCULATION FAULT CALCULATION VALUES REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND is M1 KEY INTERLOCK WESTINGHOUSE IQ DATA PLUS II MONITORING AND PROTECTION UNIT FEEDER TYPE DESIGNATION - REFER TO SINGLE LINE DIAGRAM SHEET E4 FOR FEEDER SCHEDULES GENERAL NOTES UNDER NORMAL CONDITIONS, SUBSTATION OPERATES WITH TIE BREAKER CLOSED AND MAIN BREAKER FOR BUS A (TRANSFORMER T2) CLOSED. ONE OF THE MEDIUM VOLTAGE SWITCHES FOR T2 WILL NORMALLY BE CLOSED. CONSTRUCTION NOTES PROVIDE AND INSTALL (1) 30A/2P CIRCUIT BREAKER IN POSITIONS 25,27, AND (1) 20A/1P CIRCUIT BREAKER IN POSITIONS 26,28,30,29, 1,3,5. MATCH EXISTING TYPE AND AIC RATING. PROVIDE AND INSTALL 20A/1P CIRCUIT BREAKER, IN POSITIONS 13,15,17,19,21,26,28,30. MATCH EXISTING TYPE AND AIC RATING. 4B18-1 700 A M. BKR. 3 PH, 5 W 4B18-2 100A M. BKR. 3 PH, 5 W 3018.2-1 150 A M. BKR. 3 PH, 5 W 201'4.2-1 150 A M. BKR. 3 PH. 5 W DATE SUBTITLE 1017-1 150 A M. BKR. 3 PH, 5 W 1 C1 E.4-1 150 A M. BKR. 3 PH, 5 W ISSUE FOR CONSTRUCTION AUGUST 24, 2017 ONE -LINE DIAGRAM UNIT SUBSTATION T2 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21. 2017 City of Tukwila BUILDING DIVISION , RECEIVED CITY OF TUKVJILA 3 1 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 171-062 CURRENT REVISION 33615-10 SYMBOL E DATE 08.24.17 APPROVED J. KOKOCZKA 7/25/94 APPROVED TITLE ELECTRICAL MASTER BUILDING 14-01 THOMPSON SITE SHEET E4ST2 JOB NO. 981051 COMP NO. DWG NO. 14-01-E4ST2 PS Product Integration Center\_Drawings\ 14-01-1E1 1A.DWG :\ES\Projects\ 17\ 171-062 RA 0 1- 0 0 N LoN C9 (5H9)_ AL SYM 12.4 152 13./ AL 7 3 M 3 R14 • r • 3 M 6 3 R14 3 3 R14 3 •3 R14 R14 LV 1'I 1013-1 (REF) REVISION MA E 3 3 R14 R14 KI4 V 1 1 w LV LV D 2 LV 1/2' C 2 3 C LP -101)6 11/TO R12,R13 R11 AL AL AL AL 3 R11 R10 3 R10 w 1 • • 3 3 R8 R8 innurnumt 1 • • 3 R7 ® R7 E 3 R9 R9 ® R9 it► 3 11 E 3 R10 • 3 R9 vomit R9 3 1 3 3 3 3 3 R 1 3 R7 3� • R7 3 v CH LINE SEE SHEET R14 BY APPROVED 1E14 DATE SYM 1013-1/40 J 150 REVISION 1 AL AL #11 5.2 C15.2-1/38 �� AL 15/1 1 1 R6 R6 1 1 EIE LI G HTI \ G - 1ST ELOO SCALE: 1/8" = 1'-0" BY APPROVED DATE CAD CONVERSION CADDNW 04.21.98 A MODIFY OFFICE FOR B—NN14 REWIRE LIGHTS TO EM ERG. POWER P-8 PRODUCT INTEGRATION CENTER 4993098-00 088818-00 33615-10 BOYE DE LARSON CASNE 09.23.99 CAS MN 03.28.01 08.24.17 1 • 1 1 R6 •'R R6 l� -wan imirk•mi inasaimniitifftre 4ao■P' Ista L L I 4am 4a min 1/1111111115.11 joie\ II 4b JINNI" I rr� Ili -01111111b111 P) II 4c 1 ��,~,• 4 1 4c ...�,u ��.all1►11 G D .G� � •�� 4c 1 (TVP) 4b 1• R5 :1• R5 R5 ® R51:1 1 la 11 1 4 1 o R5 1 R5 R5 w_ 1 R4 1015.2-1/38 O R5 R5 1 1 1 R5 lipMEMMEVM LCP-1C16-1/3/3R7, R8,R9,R 10,R 11,R 12,R 13,R 14 1014-1 (REF) PARTIAL PLA\ E 97 1 E11A CAT5e RS: 232 - DATA WIRING a,b,c LV 1016-1/4, 1015.2-1 (REF) 3/4"C, 2 #12, #12G C VIA LIGHTING CONTROL PANEL LCP-1C16-1, RELAY #23 CO\STUCTIO\ \OTES: PROVIDE LIGHTING FIXTURES PER LEGEND. SEE SHEET E597 FOR SEISMIC BRACING DETAIL. PROVIDE WATTSTOPPER ULTRASONIC OCCUPANCY SENSOR. MOUNT SENSOR TO UNDERSIDE OF DROPPED CEILING, WATTSTOPPER, PART # LMDC-100. PROVIDE WATTSTOPPER, 3 -ZONE, DIGITAL LIGHTING CONTROLLER. MOUNT ROOM CONTROLLER ON WALL ABOVE CEILING. WATTSTOPPER, PART # LMRC-213. PROVIDE SETUP AND COMMISSIONING OF LIGHTING CONTROL SYSTEM. PROVIDE WATTSTOPPER MOMENTARY WALL SWITCH. MOUNT AT +42"AFF. SEE DRAWING E597 FOR WIRING DIAGRAM. WATTSTOPPER, PART # LMSW-101. PROVIDE AND INSTALL DIMMER SWITCH. MOUNT AT +42"AFF. SEE DRAWING E597 FOR WIRING DIAGRAM. WATTSTOPPER, PART # LMDW-101. 6� PROVIDE CONDUIT, CONDUCTORS, BOXES, FITTINGS, AND SUPPORTIVE HARDWARE. PROVIDE LOW VOLTAGE TWISTED, SHIELDED CABLE FOR 0-10V DIMMING CONTROL. > EXISTING EMERGENCY POWER JUNCTION BOX TO REMAIN. PROVIDE WALL SWITCH OCCUPANCY SENSOR. MOUNT SWITCH AT +42" AFF. 8' 4' 0 4' 8' w 1 R3 6 R3 _ -- 1 \I� 1 - MATCH LINE 1 ifry B F 1C15.2 1/38 1 /2"0,(2)3/0#14 TO LCP-1 C16-1(REF) LCP-1 C16-1 /R3,R4 ,• LEG_ J: REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND REFER TO SHEET E501 FOR FIXTURE SCHEDULE JLV LOW VOLTAGE SWITCH WITH 1/2"C,3/C#14 TO RESPECTIVE RELAY IN LIGHTING CONTROL PANEL, UNLESS OTHERWISE NOTED. $M "MASTER" FIXTURE WITH PREWIRED 9 FT. FLEXIBLE INTERCONNECTION CABLE TO EACH OF ONE OR TWO "SLAVE" FIXTURES. CEILING MOUNTED MOTION DETECTOR, INSIGHT #OS -C CEILING MOUNTED POWER PACK, INSIGHT #OSPS-20A- 277 WALL MOUNT MOTION SENSOR, INSIGHT #IS3-1 KVA-277 $Lv WALL MOUNTED SWITCH WALLSTOPPER, PART # LMSW-101 $os WALL MOUNTED OCCUPANCY SENSOR WALLSTOPPER, PART # LMDW-101 Os CEILING MOUNTED OCCUPANCY SENSOR WATTSTOPPER/LEGRAND, PART # LMDC-100 SERIAL DATA INTERFACE (FOR A/V INTERFACE) WATTSTOPPER PART # LMDI-100 SDI RC GTD DIGITAL LIGHTING ROOM CONTROLLER WATTSTOPPER PART # LMRC-213 EMERGENCY POWER TRANSFER DEVICE PHILIPS/BODINE, PART #GTD-3A PROVIDE AND INSTALL LOCAL AREA LINE VOLTAGE WALL MOUNTED SWITCH. PROVIDE AND INSTALL SERIAL DATA INTERFACE FOR CONNECTION TO A/V. WATTSTOPPER, PART #LMDI-100. A/V SYSTEM PROVIDED BY STAGEFRONT. RS -232 DATA WIRING PROVIDED BY STAGEFRONT. PROVIDE AND INSTALL EMERGENCY POWER TRANSFER DEVICE IN THE FIXTURE. 16' SCALE: 1/8"=1'-0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN DATE CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE EFEK\CE �AWI\G: 14-01-E501 3E LIGHTING FIXTURE SCHEDULE AND DETAILS HAL \OTES 1. CONDUIT: 1/2" MINIMUM, 3/4" MINIMUM FOR ALL HOMERUNS. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. EMERGENCY LIGHTING CIRCUITS: 2#10 UNLESS OTHERWISE NOTED. 7. REFER TO SHEETS E505, E513, E514 AND E515 FOR LIGHTING CONTROL DIAGRAMS AND SCHEDULES. RECEIV TY OF TU PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION 1 rvr� CONSTRUCTION ISSUE FOR CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 AUGUST 24, 2017 gib LIGHTING PARTIAL PLAN P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ELECTRICAL MASTER COL. B -C/12.4-16 THOMPSON, WA CURRENT REVISION 33615-5-10 SYMBOL DATE 08.24.17 SHEET 1E11A JOB NO. COMP NO. DWG NO. 1 T 1E10A 1E10E3 1E11A 1E11B 1E12 1E13 1E14 1E15 -H D 1E16 1E17 1E18 1A1t99 rvr� CONSTRUCTION ISSUE FOR CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 AUGUST 24, 2017 gib LIGHTING PARTIAL PLAN P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 ELECTRICAL MASTER COL. B -C/12.4-16 THOMPSON, WA CURRENT REVISION 33615-5-10 SYMBOL DATE 08.24.17 SHEET 1E11A JOB NO. COMP NO. DWG NO. 1 P8 Product Integration Center\_Drawings\14-01 —1E61A.DWG N 0 N N 1 U a w N SYM 12/1 13.2 E 13.E (TYP.) E.1A CONTROLLED RECEPTACIIE 11.2 14.4 152 15./ 1013-1/26 DISC. SWITCH MTD. ADJACENT TO VFW ABOVE CEILING (TYP) WP 42 +48" EF -10 4HP 1013-1/42 39,41 30X70 w 30 VFW 117 LJ 41 UJ VFW -121 Cj 12 1 4HP V W-125 91 /6HP 39 REAR PROJECTION EQUIPMENT FI PROTECTED 1E61 E521 1C15.2 1C14-1/40,42 1014-1 37 TABLE TABLE 30x60 TABLE 30X70 30x60 1013-1/30 * 24 1013-1 38 38 1013-1/24 1C13-1/13,15,17 1013-1/19,21 SYSTEM FURNITURE POWER SOURCE SCHEDULE J—BOX REF. NO. PANEL NO. RECEPTACLES a PHASE b PHASE c PHASE CKT. NO. TYPE CKT. NO. TYPE CKT. NO. TYPE (1) 1C13-1 1 STD 3 STD 5 STD 14 1C14-1 20 STD 22 STD 24 STD 113 15 I/12,— 1 STD 3 STD 5 STD 16 1C15.2— 1 2 STD . • 6 STD 17 1C15.2 —1 1014-1 13 STD 15 STD 17 STD 1C15.2 —1 1C14-1 14 STD 16 STD 18 SYSTEM FURNITURE POWER SOURCE SCHEDULE J—BOX REF. NO. PANEL NO. RECEPTACLES a PHASE b PHASE c PHASE ,1 I• CKT. N0. 11• ,0 I . 1E65 1C14-1 19 STD 21 STD 23 STD 14 1C14-1 20 STD 22 STD 24 STD 113 15 I/12,— 1 STD 3 STD 5 STD 16 1C15.2— 1 2 STD . • 6 STD 17 1C15.2 —1 1014-1 13 STD 15 STD 17 STD 1C15.2 —1 1C14-1 14 STD 16 STD 18 STD SYSTEM FURNITURE POWER SOURCE SCHEDULE J—BOX REF. NO. PANEL NO. RECEPTACLES a PHASE b PHASE c PHASE CKT. NO. TYPE CKT. N0. TYPE CKT. NO. TYPE 1E65 1C14-1 19 STD 21 STD 23 STD 14 1C14-1 20 STD 22 STD 24 STD 113 15 1C15.2-1 1 STD 3 STD 5 STD 16 1C15.2— 1 2 STD 4 STD 6 STD 17 1C15.2 —1 7 STD 9 STD 11 STD 18 1C15.2 —1 8 STD 10 STD 12 STD REVISION BY APPROVED DATE SYM REVISION 1C14-1/38 BY APPROVED 208Y/120 VOLT 1ST FLOOR PARTIAL PLAN SCALE: 1/8" = 1'-0" DATE A B C D E CAD CONVERSION INSTALL POWER TO NEW WORKSTATION MODIFY OFFICE FOR B—NN14 SYSTEMS FURN MOD INSTALL A 120V RECEPTACLE J#D93P0309 J#993098 J#1000979003 WO#5111072 CADDNW AA/JB BOYE SSH HABTE 04.22.98 F BITTINGER 04.19.99 G 09.23.99 H CAS 11/19/03 J MULTIPLE SITE P-6 FLAT SCREENS UPDATE DLR/COFFMAN DESIGN RECONFIG OFFICE FOR INDUSTRIAL ATHLETE P-8 PRODUCT INTEGRATION CENTER W1877415 W3676325 33615-10 SAZAN/SL ESBROOK D. OTTEN CASNE 06.26.13 11.05.13 DLO MN 07.27.15 08.24.17 06.25.07 8' 4' 0 4' 8' 16' SCALE: 1 /8"=1'-0" 1C15.2-1/37 112.4 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN DATE CHECKED 1015.2-1/1,3,5 SUBTITLE LEGE\ D: REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND 23 J—BOX WITH 3/4"C, 8 #10 HOME RUN (3 PHASE, 3 NEUTRAL, 1 GROUND, 1 ISOLATED GROUND) FOR SYSTEM FURNITURE POWER POLE. D SYSTEM FURNITURE POWER POLE X INDICATES POINT OF SEPARATION BETWEEN POWER SOURCES IN SYSTEM FURNITURE Q SMOKE DAMPER AND SMOKE DETECTOR AUXILIARY CONTACT. CONNECT PER DETAIL 3, SHEET E538 DR J—BOX INTERFACE WITH ELECTRIC DOOR RELEASE. SEE DETAIL 2, SHEET E538. GE HAL COTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) B 0 CENTER BUS IN PNL) C 0 RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND BLACK RED BLUE WHITE GREEN BROWN ORANGE YELLOW GRAY GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. Vending Machine 8 > I 9 > CoffeeceMachine Maker 10 > (2) Microwaves Stacked Refrigerator RECEIVED CITY OF TUKWILA €. �`�; JO' ,Cr Fj! n PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 1 2017 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION ISSUE FOR CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 171-062 AUGUST 24, 2017 208Y/120V 1ST FLOOR PARTIAL PLAN CURRENT REVISION SYMBOL 33615-10 J DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 THOMPSON, WA SHEET 1E61A JOB NO. COMP NO. DWG NO. 14-01-1E61A 10.48.16 AM 1 E60A 1 E60B,1E61A 1 E61 B 1E62 1E63 1E64 1E65 1E67 1E68 1E69 1E66 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN DATE CHECKED 1015.2-1/1,3,5 SUBTITLE LEGE\ D: REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND 23 J—BOX WITH 3/4"C, 8 #10 HOME RUN (3 PHASE, 3 NEUTRAL, 1 GROUND, 1 ISOLATED GROUND) FOR SYSTEM FURNITURE POWER POLE. D SYSTEM FURNITURE POWER POLE X INDICATES POINT OF SEPARATION BETWEEN POWER SOURCES IN SYSTEM FURNITURE Q SMOKE DAMPER AND SMOKE DETECTOR AUXILIARY CONTACT. CONNECT PER DETAIL 3, SHEET E538 DR J—BOX INTERFACE WITH ELECTRIC DOOR RELEASE. SEE DETAIL 2, SHEET E538. GE HAL COTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) B 0 CENTER BUS IN PNL) C 0 RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND BLACK RED BLUE WHITE GREEN BROWN ORANGE YELLOW GRAY GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. Vending Machine 8 > I 9 > CoffeeceMachine Maker 10 > (2) Microwaves Stacked Refrigerator RECEIVED CITY OF TUKWILA €. �`�; JO' ,Cr Fj! n PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 1 2017 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION ISSUE FOR CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 171-062 AUGUST 24, 2017 208Y/120V 1ST FLOOR PARTIAL PLAN CURRENT REVISION SYMBOL 33615-10 J DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 THOMPSON, WA SHEET 1E61A JOB NO. COMP NO. DWG NO. 14-01-1E61A 10.48.16 AM P8 Product Integration Center\_Drawings\14-01-1 E411A.DWG 0 I :\ES\Projects\ 17\ 171-062 RA co 0 0 00 SYM 12.E 132 13.E 15.2 15./1 KVM MONITOR (MOUNTED AT CEILING OF THE BOX) EQUIPMENT RACK BACK BOX PROJECTION STAND 30X70 A/V WALL INTERFACE PLATE 4 R 'ROJECi1ON QUIPMENT LCD MONITOR10 MONITOR (VIDEO WALL) +54" VADDIO #999-2225-015 EXITING DATA OUTLET 13B16-5122 A/V WALL INTERFACE PLATE 4 TAB LE 30x60 30X70 El I REVISION BY APPROVED DATE SYM REVISION BY \ETWO� - 1ST FEDO LCD MONITOR CEILING MOUNTED -DATTIAL PLA\ SCALE: 1/8" 1'-0" APPROVED DATE P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 13B16-5122 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED OVED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE (c) LEGE\ 11 tt �1 —0 DATA DROPS (# OF PORTS) FLOOR BOX FSR, FL -500P SEE SHEET E598 2—GANG BACK BOX CONDUIT TURNING UP CONDUITS IN TRENCH NOTE: FIELD VERIFY MOUNTING HEIGHT AND EXACT LOCATION OF ALL A/V OUTLETS FOR A/V EQUIPMENT WITH STAGEFRONT SHEETS PS100 & PS101 PRIOR TO ROUGH—IN. CO\STUCTIO\ \OYES • PROVIDE DATA DROP WITH IN—WALL 1 1/4" CONDUIT PATHWAY TO INTERSTITIAL SPACE ABOVE DROPPED CEILING. PROVIDE NYLON PULL STRING IN CONDUIT AND BUSHING FOR CABLE PULL BY OTHERS. EXISTING OUTLET TO REMAIN. ROUTE DATA AND A/V CONDUCTORS VIA 1-1/4" CONDUITS VIA 6"WX6"D TRENCH. TRENCH BY OTHERS. PROVIDE AND INSTALL (1) SHADOW BOX (28"X28"X6") WITH (1) 1" CONDUIT STUBBED UP INTO ACCESSIBLE CEILING SPACE AND CAP. PROVIDE CONDUIT WITH NYLON PULL STRING AND BUSHING. BOEING TO PROVIDE AND INSTALL (5) NETWORK DROPS MOUNTED IN WALL BEHIND RACK. CONVERT EXISTING DATA OUTLET TO BE CAPABLE OF RECEIVING (2) DATA DROPS. PROVIDE AND INSTALL (2) 1-1/4" CONDUIT ONLY WITH NYLON PULL STRING AND BUSHING FROM A/V FLOOR BOX TO ABOVE ACCESSIBLE CEILING SPACE VIA TRENCH. CONTRACTOR TO PROVIDE AND INSTALL (6) CAT6 CABLES FOR A/V, AND (2) CAT5e CABLES FOR DATA. HELD VERIFY TERMINATION POINT. AT THE STUB—UP OVER THE CEILING SPACE, CONTRACTOR TO LABEL (1) 1-1/4" CONDUIT AS A/V, AND (1) 1-1/4" CONDUIT AS DATA. PROVIDE AND INSTALL RECESSED MOUNTED FLUSH ENCLOSURE IN WALL. VADDIO #999-2225-015 FOR CONNECTION TO INTERACTIVE CAMERA SYSTEM. CAMERA FURNISHED BY OWNER. PROVIDE AND INSTALL 1-1/4" CONDUIT WITH PULL STRING AND BUSING TO ABOVE ACCESSIBLE CEILING SPACE AND CAP. 10 PROIVE AND INSTALL (2) 1-1/4" CONDUIT ONLY WITH PULL STRING AND BUSING TO ABOVE ACCESSIBLE CEILING SPACE. 8' 4' 0 4' 8' 16' RECEI CITY OF TUr.,, PROVIDE AND INSTALL EQUIPMENT RACK BACK BOX WITH (1) 6'X6"X3" S ; 'E-W—CQV.- EBBED AND MOUNTED AT +1 /6;.- VIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION 112.4 SCALE: 1 /8"=1'-0" rld3 1 2.3 KEY PLAN P ERNIIT CENTER SCALE: NONE ISSUE FOR CONSTRUCTION AUGUST 24, 2017 NETWORK - 1ST FLOOR PARTIAL PLAN 1 CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 1 604 NE 38th PL., SUITE 205 KIRKLAND, WA 980. (425) 522-1000 www recuF rnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 98033 WWW.CASNE.COM NO. 171-062 CURRENT REVISION SYMBOL 33615-10 DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 THOMPSON, WA SHEET 1E411A JOB NO. COMP NO. DWG NO. 14-01-1 E411 A 10.48.1 A AM Lr: N N c —71 1E410A 1E4108 1E411A 1E411B 1E412 1E413 1E414 1E415 —H -D 1E416 1E417 1E418 1E419 SCALE: 1 /8"=1'-0" rld3 1 2.3 KEY PLAN P ERNIIT CENTER SCALE: NONE ISSUE FOR CONSTRUCTION AUGUST 24, 2017 NETWORK - 1ST FLOOR PARTIAL PLAN 1 CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 1 604 NE 38th PL., SUITE 205 KIRKLAND, WA 980. (425) 522-1000 www recuF rnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 98033 WWW.CASNE.COM NO. 171-062 CURRENT REVISION SYMBOL 33615-10 DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 THOMPSON, WA SHEET 1E411A JOB NO. COMP NO. DWG NO. 14-01-1 E411 A 10.48.1 A AM Lr: N N c P8 Product Integration Center\_Drawings\14-01—E501.dwg LIGHT FIXTURE SCHEDULE TYPE SYMBOL TOTAL DESCRIPTION MOUNTING FIXTURE PHILIPS LAMPS BALLAST MANUFACTURERS CATALOG REMARKS TYPE SYMBOL WATTAGE DESCRIPTION MOUNTING VOLTAGE TYPE QTY. LED SERIES NUMBER MULE MXAGU MASTER 91 7"X4' RECESSED FLUORESCENT MATCHING 277 V F032/T8 3 REFER TO ZUMTOBEL FACTORY FURNISHED 9' 277V 0FIXTURE - TANDEM WIRED (MASTER/ CEILING BRUSHED ALUMINUM FINISH 3500K 20 SPECIFICATION #RNC-1/32-277-EB-M/S/S FLEXIBLE TANDEM HARNESS (A) SLAVE(2) 20 SLAVE/SLAVE) 1 -LAMP, 18 CELL SYSTEM 277V 32W - SECTION 16510 SERIES TO EACH SLAVE FIXTURE (2) 20 PARABOLIC HIGH EFFICIENCY F-0 19 FLUORESCENT EXIT SIGN END/BACK 277V F5TT SEE DETAILS THIS SHEET MASTER 59 7"X4' RECESSED FLUORESCENT MATCHING 277 V F032/T8 2 REFER TO ZUMTOBEL FACTORY FURNISHED 9' ��FIXTURE TANDEM WIRED (MASTER/ CEILING 3500KSPECIFICATION#RNC-1/32-277-EB-M/S FLEXIBLE TANDEM HARNESS C59B SLAVE SLAVE) 1 -LAMP, 18 CELL SYSTEM 32W SECTION 16510 SERIES TO SLAVE FIXTURE 1 PARABOLIC HIGH EFFICIENCY SEE ?ETAILS THIS SHEET 31 7"X4'RECESSED FLUORESCENT MATCHING 277 V F032/T8 1 REFER TO ZUMTOBEL Q�� FIXTURE MASTER CONFIGURATION CEILING 3500K SPECIFICATION #RNC -1/32 -277 -EB -M SECTION 16510 SERIES ® 1 LAMP, 18 CELL PARABOLIC SYSTEM 32W HIGH EFFICIENCY. MASTER 111 12"x4' FLUORESCENT MATCHING 277 V F032/T8 4 REFER TO ZUMTOBEL FACTORY FURNISHED 9' CEILING 3500K SPECIFICATION RNC -2/32 -277 -EB -M/S FLEXIBLE TANDEM HARNESS D FIXTURE (MASTER/SLAVE) SLAVE 2 LAMP, 36 CELL PARABOLIC SYSTEM 32W SECTION 16510 SERIES TO SLAVE FIXTURE SEE DETAILS THIS SHEET HIGH EFFICIENCY 59 12"X4' RECESSED FLUORESCENT MATCHING 277 V F032/T8 2 REFER TO ZUMTOBEL FIXTURE, MASTER CONFIGURATION CEILING 3500K SPECIFICATION RNC -2/32 -277 -EB -M r_=, ``'J 32W SECTION 16510 SERIES 59 2 LAMP, 36 CELL PARABOLIC SYSTEM HIGH EFFICIENCY 59 12"X4' SURFACE MOUNT SURFACE 277 V F032/T8 2 REFER TO LITHONIA FIXTURE WITH WRAP- CEILING 3500K SPECIFICATION VC -232-A-277 �_�__, 59 '--J AROUND ACRYLIC LENS' 32W SECTION 16510 2 LAMP 59 12"X4' FLUORESCENT UNISTRUT, SEE 277 V F032/T8 2 REFER TO LITHONIA PROVIDE 4' WIRE GUARD INDUSTRIAL WITH 20% DETAIL 3500K SPECIFICATION AF -232 -A -277 -ES ,_a_ '--J 59 UPLIGHT, BAKED WHITE 32W SECTION 16510 ENAMEL FINISH, WIRE GUARD 150 INCANDESCENT TRACK LIGHT TRACK 120V 150 T4 1 N/A PRESCOLITE PROVIDE SINGLE CIRCUIT Q WITH BLACK LOUVER QUARTZ TLC -6 SURFACE MOUNT TRACK AND WWHITE FINISH 150W SERIES REQ'D CONNECTORS, WHITE FINISH 35 6 INCH DIAMETER APERTURE RECESSED 277V F13 DTT 2 HPF, CBM PRESCOLITE Q r.s.COMPACT FLUORESCENT DOWNLIGHT QUAD ENERGY SAVING PBX -TO -9452-13 ® WITH CLEAR SPECULAR CONE 3500K FUSED 59 12"X4' SURFACE FLUORESCENT SURFACE 277V F032/T8 2 REFER TO LITHONIA REPLACEMENT FIXTURE AT WITH ONE PIECE ACRYLIC 3500K SPECIFICATION WA -2 -32 -277 -ES EXIST. STAIRS AND NEW ,_�_ 59 _J WRAPAROUND DIFFUSER, WHITE 32W SECTION 16510 STAIR ENAMEL FINISH 59 12"X4' SURFACE MOUNT FLUORESCENT SURFACE 277V F032/T8 2 REFER TO ZUMTOBEL FIXTURE, WITH PARABOLIC MATT- 3500K SPECIFICATION RAC -2/32-277 ....--r---02-- 59 J SILVER FINISHED LOUVERS 32W SECTION 16510 SERIES 59 4'LONG WALL MOUNT FLUORESCENT WALL © +9'-6" 277V F032/T8 2 REFER TO LITHONIA FIXTURE, WITH ACRYLIC UPPER & 3500K SPECIFICATION W -232 -277 -ES rte_ 59 --' LOWER DIFFUSERS BRUSHED ALUM 32W SECTION 16510 END PLATES 75 INCANDESCENT WALL BRACKET WALL 120V 75A/RP 1 N/A HUBBELL P WITH TEMPERED GLASS GLOBE A19 MED VW -151 (BODY) AND CAST ALUMINUM GUARD BASE 1005 (GLOBE)GLD) VGCP -4 ....I ' 212 METAL HALIDE WITH HEAVY DUTY SURFACE 277V MS175/ 1 PEAK LEAD HOLOPHANE R ALUM. HOUSING & INJECTION MOLD- C/HOR AUTOTRANSFORMER/MT PARK-175MH-27-QI- �►7 ED POLYCARBONATE REFRACTOR FOR MOGUL BZ -S -F1 SYMMETRICAL DISTRIBUTION. BASE 150 SQUARE INCANDESCENT WITH SURFACE 120V 150/A-21 1 N/A PRESCOLITE / S 0 STEEL HOUSING & WHITE RIBBED CEILING MED BASE 9437 15 POLYCARBONATE DIFFUSER. INSIDE FROST 207 1' X 8' FLUORESCENT INDUSTRIAL SURFACE 277V F96T12/ 2 REFER TO LITHONIA PROVIDE (2) #WG3, WIRE T WITH WITH NO UPLIGHT, WHITE POLYESTER D36/H0/ SPECIFICATION #AFST-296-H0-277 GUARDS PER FIXTURE. r— `-J 207 FINISH, HIGH OUTPUT LAMPS. SEE SS SECTION 16510 REMARKS. 3500K 59 2' X 4' RECESSED FLUORESCENT RECESSED 277V F032/T8 2 ELECTRONIC LITHONIA TROFFER WITH 24 CELL PARABOLIC 3500K #2PM2GB23224D277 59 HO SEMI -SPECULAR SILVER DIFFUSER, 32W GMF GEB FUSED WITH ELECTRONIC BALLAST 58 12' COLUMBIA IT4 ROTATABLE PENDANT 277V F032/T8 2 ELECTRONIC COLUMBIA QI ASYMMETRIC DOWN LIGHT 3500K IT4-1ADT8-PM4-WCB-EB8277- 32W MW-12SGL-RT/GLR 58 WHITE CROSS BAFFLE FAST FUSED 40 2'X 4' LED, SMART FLAT PANEL, WITH RECESSED 277V LED DRIVER 0-10V DECO LIGHTING SFP-LED-24-40-35-UNV 3500K 4623 LUMEN 070) 0-10 DIMMING, FROSTED POLYCARBONATE DIFFUSER 0IMMIVG 277V LED DRIVER 3500K 30 2'X 2' LED, SMART FLAT PANEL, WITH RECESSED DECO LIGHTING 30 0-10V DIMMING, FROSTED 0-10V SEP-LED-22-30-35-UNV 4623 LUMEN DIMMING POLYCARBONATE DIFFUSER EX DETAIL D DRAWING OR OR EMERGENCY HIGHBAY 55 ® (HO) STEEL HOUSING, PORCELAIN 114-001-2001-E131 ENERGY SAVING TYPE COLUMBIA LIGHTING FIXTURES FROM COL 12.4 REFLECTOR, 15% UPLIGHT, HIGH OUTPUT LAMPS (800mA), INDIVIDUALLY FUSED, #KL8-296H0-PR-LE277-GLR TO 19 HAVE BEEN CHANGED TO T5H0, HE Williams #84-8-454T5H-W08414-VBY-2 DURING P8 PHASE 1 REMODEL. CIRCUITS REMAINED THE SAME. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A B C RECORD DRAWING (FDS) ADD FIXTURE TYPE EX/255 ADD FIXTURE TYPE V/58 737 MMA ITAR RECORD DRAWING J#993129 WO 70041 J11557296-00 RH/RH KR DE LARSON KNOX DLR GROUP JK CS CAS 03.31.95 D P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 01.17.00 02.09.01 04.26.06 JH 07.08.11 LIGHT FIXTURE SCHEDULE TYPE SYMBOL TOTAL WATTAGE DESCRIPTION MOUNTING FIXTURE VOLTAGE PHILIPS LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS TYPE QTY. 1-0 3 LED EXIT SIGN CEILING, END, OR BACK 120/277V LED - MULE MXAGU WHITE THERMOPLASTIC 6"H X 3/4"W GREEN LL I I ERS ON WHITE BKGND SNAP -IN ARROWS SINGLE OR DOUBLE FACE 20� O 20 FLUORESCENT EXIT SIGN 6"H X 3/4"W GREEN LETTERS ON CLEAR BKGND NO ARROWS SINGLE FACE CEILING/END 277V F8T5 - LITHONIA F2RP-1-GC-277 SERIES BRUSHED ALUMINUM FINISH 20 i 1 1-0 20 FLUORESCENT EXIT SIGN 6"H X 3/4"W GREEN LETTERS ON CLEAR BKGND DOUBLE FACE WITH ARROWS AS INDICATED ON PLAN END 277V LED - LITHONIA F2RP-2-GC-277 SERIES BRUSHED ALUMINUM FINISH 20 F-0 19 FLUORESCENT EXIT SIGN END/BACK 277V F5TT 2 LITHONIA F2E-SW1G-277 SERIES BRUSHED ALUMINUM FINISH ® 6"H X 3/4"W GREEN LL I ERS, DOUBLE FACE WITH ARROWS AS INDICATED ON PLAN 19 SEISMIC FIXTURE SUPPORT WIRES. SECURE TO STRUCTURE ABOVE NEW FIXTURE (SEE FIXTURE SCHEDULE FOR TYPE) SEISMIC CLIPS (TYPICAL EACH END OF FIXTURE) •ECESSED FIXT.,H TYPICAL CEILING TILE TRIM (MANUFACTURED ON FIXTURE) EXISTING CEILING TILE PROVIDE CEILING TILE FILLERS NEW CEILING SUPPORT GRID I\STALLATIO\ ;ETAIL SCALE: NONE TO SECOND SLAVE FIXTURE (IF REQUIRED) (-71� E501 FLEXIBLE TANDEM HARNESS, TIP. (SUPPLIED WITH FIXTURES) D LEGE\ REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND GE\ SAL \OYES 'EFFE\CE NAWI\JS CO\STCTIO\ NOTES PROVIDE AND INSTALL LIGHT FIXTURE. SEE SHEET 1 E11 A FOR LIGHTING LAYOUT. MASTER FIXTURE FLUORESCE\T FIXTURE DETAIL SCALE: NONE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN B. FISH DATE CHECKED J. BITTINGER SUBTITLE SLAVE FIXTURE E501 RECEIVED CITY OF TUK` ILA 3 1L' PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 20V City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTIONCASNEENGINEERING, INC. AUGUST 24, 2017 v LIGHTING FIXTURE SCHEDULE & DETAILS E�� «z ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM JOB NO. 171-062 CURRENT REVISION SYMBOL 33615-10 DATE 08.24.17 ENGINEER B. FISH CHECKED R. HAMMETT APPROVED J, KOKOCZKA APPROVED 07.25.94 TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. B -E/6-19 THOMPSON, WA SHEET E501 JOB NO. COMP NO. DWG NO. 14-01-E50 1 7.77.3:1 PM 2 -LAMP BALLAST TO LIGHT FIXTURES) IJ OCCUPANCY SENSOR BASIC OCCUPANCY CONTROL 2 -LAMP FIXTURE 1 -LAMP FIXTURE 2 -LAMP BALLAST ALTERNATE FIXTURE TYPES ; • 4 • • • • • • .• .• • • .• • • .• • • ., LL Q w o�D 0 X EL: LAMP (TYP) 7R9 2 FIXTURE MASTER/SLAVE CONFIGURATION 3 -LAMP BALLAST N N TO ADDITIONAL FIXTURES ON SAME CIRCUITS • 7810 N 7R9 3 FIXTURE MASTER/SLAVE CONFIGURATION N J LLJ l 0) c r` 16 LOW VOLTAGE RELAY - POWER TERMINALS (TYP) 7R9 7R10 TYPICAL HOMERUN CALLOUT LCP 1C16-1/7/7R9,R10,R11 * 7 INDICATES NON -RELAY CONTROLLED CIRCUIT * 7R9,R10,R11 INDICATES CONTROL FROM RELAYS R9,R10 & R11 VIA CKT. 7 LOW VOLTAGE LIGHTING CONTROL PANEL. LCP 1C16-1 (TYPICAL CONTROL PANEL CALLOUT) 24 RELAY PANEL (48 RELAY PANEL SIMILAR) LOW VOLTAGE WIRING TERMINALS (TYP) C0 C 0 0 00 ooloo 00 7R11 7 0 r°0 O NEUTRAL i0 O 0 C R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 CIRCUIT 7 W R BK W R o3 PROGRAMMABLE SYSTEM SWITCHES 6 4 I 1 TYPICAL RELAY USAGE - SEE LIGHTING CONTROL SCHEDULES FOR ACTUAL ASSIGNMENTS H N G LL 5 W R BK W R BK R13 R14 R15 R16 R17 R18 R19 IooI looI lo °I 1o01 IooI lo 0 r 1 R24 LCP 3C15.4-2 ONLY PROGRAM CARDS LCP 1016-1 ONLY TIME "ON" "OFF" SIGNAL IN OUT SHLD 4 4 4 1 OFF LOW VOLTAGE WALL SWITCH LCP COMPONENTS (TYP) RTUB24 CABINET RINTER2424 INTERIOR W/RELAYS RPWR277 POWER SUPPLY RCOV24SHL COVER RRDC12 CARDS (2) RCC24 PANEL CONTROLLER CARD TO OUTDOOR PHOTOCELL ON NORTH CANOPY SEE SHEET E503 WHITE (COMMON) BLACK (OFF) RED (ON) LCP 109.2-1 7 > 8 LOW VOLTAGE CONTROL TYPICAL CONTROL RUN LCP 1C16 -1/R7 1/2"C, 3/0 #14 LCP 1016-1 LCP 2C9-1 NETWORK INTERFACE (SEE DIAGRAM BELOW) WIRING (CLASS 2) CALLOUT 3/4"C, 2/0 #18 TWISTED LIGHTING CONTROL NETWORK CABLE (TYP) (G.E. RDWIRES-2S) 1 LCP 2C15.4-2 LCP 3C9-1 6> W 480/277 V LIGHTING PANELBOARD. 1 C16-1 (TYPICAL PANELBOARD CALLOUT) A B C 4 6 ---cam -0 ---013 0 15^ �-0 —cam °� �� 0 —19 2023 --- -o 25X20 27 n .--• 28 _0- —o 29 30 31 .--. 32 33 n 34 —0 38 39 40 41 �-�• ,e -N 420 POWER SOURCE FOR LIGHTING CONTROL PANEL - SEE PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBER 0 0 tY WHITE BLUE BLACK RED LIGHTING CONTROL NETWOR < DIAGRAM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P-8 PROJECT INTEGRATION CENTER RH JK 08.24.17 LCP 3C15.4-2 SET TO 50 fc / � SET TO 40 fc a, LO HI ❑ 22 ❑ 21 ❑ 14 ❑ 13 MULTIPOINT LC4P-PC1A CONTROLLER MOUNTED IN 4TH FLOOR ELECTRICAL VAULT SEE SHEET 4E11 BLACK -J RED —� MULTIPOINT PC1A DAYLIGHT SENSOR REFER TO PLAN DRAWINGS FOR LOCATION SEE SHEET 3E11 DAYLIGHT SENSOR DETAIL CONNECT TO HIGH BAY LIGHTING NETWORK IN EXISTING 4TH FLOOR TELEPHONE ROOM REFER TO SHEET E504 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED OVED BY DEPT. DATE DRAWN DATE CHECKED LEGEND: REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND GENERAL NOTES: PROVIDE LIGHTING CONTROL PANELS (LCP'S) WHERE INDICATED ON THE LIGHTING PLAN DRAWINGS. REFER TO MANUFACTURER'S INSTRUCTION LITERATURE FOR DETAILED INSTALLATION AND WIRING TERMINATION INFORMATION ON THE G.E. TLC LOW VOLTAGE LIGHTING CONTROL SYSTEM. CIRCUIT NUMBERS SHOWN FOR LIGHTING CONTROL PANEL AND LIGHTING PANELBOARD ARE FOR EXAMPLE ONLY. REFER TO PLAN DRAWINGS AND PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBERS. INSTALL WIRING BETWEEN ALL LIGHTING CONTROL PANEL RELAYS AND LIGHTING PANELBOARDS AS REQUIRED. LIGHTING CONTROL PANEL CONTROL BOARD AND ACCESSORY BOARDS TO PROVIDE CONTROL IN ACCORDANCE WITH THE SPECIFICATIONS. 1 6 > REFER TO SHEET E502 FOR ELEVATION VIEW OF THE LIGHTING CONTROL PANEL AND ASSOCIATED LIGHTING PANEL. CEILING TILE SUBTITLE ISSUE FOR CONSTRUCTION AUGUST 24, 2017 DETAILS LIGHTING CONTROL DIAGRAM CONTROL WIRING CALLOUT MAY NOT APPEAR ON PLAN DRAWINGS, BUT MUST BE INCLUDED FOR ALL LOW VOLTAGE SWITCHES SHOWN. 8 > LOW VOLTAGE CONTROL CIRCUITS FOR MORE THAN ONE SWITCH MAY BE COMBINED IN COMMON CONDUITS WHERE FEASIBLE. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA r 3 1 7 PERMIT CENTER CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98 . (425) 522-1000 wwwras�vF cou JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th 205 KIRKLAND, WA 98033 WWWCASNE.COM JOB 171-062 CURRENT REVISION SYMBOL A DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-01 COL. B -E/6-19 THOMPSON, WA SHEET E505 JOB NO. COMP NO. DWG NO. 14-01-1505 BLU i` o R BK Y W \ RBKY W 0 RR BK Y W RBKY W o o �W RR BK Y RBKY W o R BK Y W R BK Y 0 RBKY W RBKY W 0 0 R BK Y W RBKY W O R BK Y W RBKY W 0 RBKY W RBKY W R BK Y W R BK Y W RBKY W RBKY W o o RR BK Y W RBKY W 0 R BK Y W RBKY WW o W R BK W R o3 PROGRAMMABLE SYSTEM SWITCHES 6 4 I 1 TYPICAL RELAY USAGE - SEE LIGHTING CONTROL SCHEDULES FOR ACTUAL ASSIGNMENTS H N G LL 5 W R BK W R BK R13 R14 R15 R16 R17 R18 R19 IooI looI lo °I 1o01 IooI lo 0 r 1 R24 LCP 3C15.4-2 ONLY PROGRAM CARDS LCP 1016-1 ONLY TIME "ON" "OFF" SIGNAL IN OUT SHLD 4 4 4 1 OFF LOW VOLTAGE WALL SWITCH LCP COMPONENTS (TYP) RTUB24 CABINET RINTER2424 INTERIOR W/RELAYS RPWR277 POWER SUPPLY RCOV24SHL COVER RRDC12 CARDS (2) RCC24 PANEL CONTROLLER CARD TO OUTDOOR PHOTOCELL ON NORTH CANOPY SEE SHEET E503 WHITE (COMMON) BLACK (OFF) RED (ON) LCP 109.2-1 7 > 8 LOW VOLTAGE CONTROL TYPICAL CONTROL RUN LCP 1C16 -1/R7 1/2"C, 3/0 #14 LCP 1016-1 LCP 2C9-1 NETWORK INTERFACE (SEE DIAGRAM BELOW) WIRING (CLASS 2) CALLOUT 3/4"C, 2/0 #18 TWISTED LIGHTING CONTROL NETWORK CABLE (TYP) (G.E. RDWIRES-2S) 1 LCP 2C15.4-2 LCP 3C9-1 6> W 480/277 V LIGHTING PANELBOARD. 1 C16-1 (TYPICAL PANELBOARD CALLOUT) A B C 4 6 ---cam -0 ---013 0 15^ �-0 —cam °� �� 0 —19 2023 --- -o 25X20 27 n .--• 28 _0- —o 29 30 31 .--. 32 33 n 34 —0 38 39 40 41 �-�• ,e -N 420 POWER SOURCE FOR LIGHTING CONTROL PANEL - SEE PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBER 0 0 tY WHITE BLUE BLACK RED LIGHTING CONTROL NETWOR < DIAGRAM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P-8 PROJECT INTEGRATION CENTER RH JK 08.24.17 LCP 3C15.4-2 SET TO 50 fc / � SET TO 40 fc a, LO HI ❑ 22 ❑ 21 ❑ 14 ❑ 13 MULTIPOINT LC4P-PC1A CONTROLLER MOUNTED IN 4TH FLOOR ELECTRICAL VAULT SEE SHEET 4E11 BLACK -J RED —� MULTIPOINT PC1A DAYLIGHT SENSOR REFER TO PLAN DRAWINGS FOR LOCATION SEE SHEET 3E11 DAYLIGHT SENSOR DETAIL CONNECT TO HIGH BAY LIGHTING NETWORK IN EXISTING 4TH FLOOR TELEPHONE ROOM REFER TO SHEET E504 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED OVED BY DEPT. DATE DRAWN DATE CHECKED LEGEND: REFER TO SHEET E1 FOR GENERAL SYMBOLS LEGEND GENERAL NOTES: PROVIDE LIGHTING CONTROL PANELS (LCP'S) WHERE INDICATED ON THE LIGHTING PLAN DRAWINGS. REFER TO MANUFACTURER'S INSTRUCTION LITERATURE FOR DETAILED INSTALLATION AND WIRING TERMINATION INFORMATION ON THE G.E. TLC LOW VOLTAGE LIGHTING CONTROL SYSTEM. CIRCUIT NUMBERS SHOWN FOR LIGHTING CONTROL PANEL AND LIGHTING PANELBOARD ARE FOR EXAMPLE ONLY. REFER TO PLAN DRAWINGS AND PANEL SCHEDULES FOR ACTUAL CIRCUIT NUMBERS. INSTALL WIRING BETWEEN ALL LIGHTING CONTROL PANEL RELAYS AND LIGHTING PANELBOARDS AS REQUIRED. LIGHTING CONTROL PANEL CONTROL BOARD AND ACCESSORY BOARDS TO PROVIDE CONTROL IN ACCORDANCE WITH THE SPECIFICATIONS. 1 6 > REFER TO SHEET E502 FOR ELEVATION VIEW OF THE LIGHTING CONTROL PANEL AND ASSOCIATED LIGHTING PANEL. CEILING TILE SUBTITLE ISSUE FOR CONSTRUCTION AUGUST 24, 2017 DETAILS LIGHTING CONTROL DIAGRAM CONTROL WIRING CALLOUT MAY NOT APPEAR ON PLAN DRAWINGS, BUT MUST BE INCLUDED FOR ALL LOW VOLTAGE SWITCHES SHOWN. 8 > LOW VOLTAGE CONTROL CIRCUITS FOR MORE THAN ONE SWITCH MAY BE COMBINED IN COMMON CONDUITS WHERE FEASIBLE. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA r 3 1 7 PERMIT CENTER CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98 . (425) 522-1000 wwwras�vF cou JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th 205 KIRKLAND, WA 98033 WWWCASNE.COM JOB 171-062 CURRENT REVISION SYMBOL A DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-01 COL. B -E/6-19 THOMPSON, WA SHEET E505 JOB NO. COMP NO. DWG NO. 14-01-1505 P8 Product Integration Center\_Drawings\14-01—E597.dwg I:\ES\Projects\17\171-062 RA 4" OCTAGONAL J—BOX (AT LEAST 1.5" DEEP) RJ -45 CEILING HOLE LMRJ SERIES CEILING HOLE PRE—TERMINATED pridel'i■ CABLES OR CAT5e. CEILING SYM OCC 'DA\CY SCALE: NONE REAR HOUSING CEILING LMRJ SERIES PRE—TERMINATED CABLES OR CAT5e. FRONT COVER SE\SO FRONT COVER vOJ\TI\G DETAIL E 971,EI,A CONDUIT AND J—BOX ANCHORED TO CEILING ANCHOR TO CEILING 12 GAGE WIRE HANGER AS REQUIRED FOR GRID MEMBER SUPPORT FLEXIBLE CONDUIT SECURELY FASTEN THE LIGHTING FIXTURE TO THE CEILING FRAMING it •... MECHANICAL MEANS #��� APPROVED FOR THE PURPOSE �� J1°. / PROVIDE WITH TRIM FOR RECESSING FIXTURE INTO SUSPENDED CEILING NORMAL l Neutral (Wht). AC Hot (Blk) POWER 277V Occupancy Sensor LMDC-100 DEVICES ARE ADJUSTMENT Sequence of to establish adjustments REVISION (TYP) OF 2 0-1OV DIMMING Red Yel Lighting Load (a) 0-10V Dimming Lighting Load (b) Win CD *NOTE: Ceiling mount Sensor has two RJ45 ports. 11 I 1 I I 1 I I I I I I I I 1 1 •-1 I H 1 LMRC-213 Dimming Room Controller Blu 0-10V Dimming Lighting Load (c) Vio Vio -- Gry__I 1 I 1� 0 0 0 0 of 1.o1 1.o1 1 51.1 1 1ILL I L L L LMRJ—C8 Coupler CAT5e (TYPICAL) RJ45 Port (Typical) Class 2 0-10 Vol t Control Wiring (TYP) LMRJ Series Pre—Terminated Cables or CAT5e. Free Topology & Splitter Acceptable JJ JJ ICESSE SCALE: NONE GEN TRANS DEVICE N H GEN TRANS DEVICE UNITS SHALL BE SUITABLE FOR AIR SUPPLY (WHERE INDICATED ON THE DRAWING) LOUVERED OR LENSED FIXT��E SEISNIC 3AC1\G TO EMERGENCY CIRCUIT (SEE DRAWING 1E11A) LIGHTING LOAD EMERG. 1 1 1 1 1 1 J I _J 1 r' LIGHTING LOAD EMERG. (a) (c) LMDI-101 SERIAL DATA INTERFACE (SDI) INTERTIE TO SATELLITE UNIT (WHERE INDICATED ON DRAWINGS) WIRE OR OTHER APPROVED HANGER AS REQUIRED FOR LIGHTING FIXTURE SUPPORT U°U°U° LED TYPE "Y" LMDW-101 LMDW-101 LMDW-101 LMSW-101 MOMENTARY MOMENTARY MOMENTARY MOMENTARY SWITCH SWITCH SWITCH SWITCH • • • 0 • 0 RJ45�"- (Typical) (a) (b) (c) PRESET FOR PLUG n' GOTM OPERATION, IS OPTIONAL. Operation: WattStopper's exclusive control algorithm uses on/off or dimming setpoints and other control parameters the correct light levels throughout the day regardless of changing daylight contribution. For full operational details, and more features of the product, see the DLM System Installation Guide at www.wattstopper.com BY APPROVED DATE SYM REVISION SWITCH BOX MOUNTED FLUSH WITH WALL. NO SURFACE MOUNTED INSTALLATION 4—GANG BOX 4—GANG DECORA COVER PLATE ALL "ON/OFF" -YPICAL OPEN OFFICES - CONTROLS WIRING DIAGRAM LIGHTING SEQUE\CE OF OPPATIO\ SCALE: NONE E597 1E11A BY APPROVED DATE P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 1. LMSW-100 SWITCH TURNS ON ASSOCIATED FIXTURES WHEN MANUALLY ACTIVATED. 2. LMDC-100 OCCUPANCY SENSORS WORK IN TANDUM TO DETECT PRESENCE. AFTER BOTH SENSORS HAVE NOT DETECTED PRESENCE FOR A TIME PERIOD OF 15 MINUTES, ALL FIXTURES IN THE AREA ARE TURNED OFF. FIXTURES ARE TURNED ON AGAIN WHEN MANUALLY ACTIVATED USING LMSW-100 SWITCH. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED VED BY DEPT. DATE DRAWN C. CLEVER RS -232 DATA WIRING TO A/V SYSTEM (PROVIDED & INSTALLED BY STAGEFRONT) DATE 04.08.11 CHECKED SUBTITLE LEGE\J G \ERAL \OT=S EFEH\CE D AWI \GS ISSUE FOR CONSTRUCTION AUGUST 24, 2017 DETAILS CO\STUCTIO\ \CTES REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA a;T 31 7 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 CURRENT REVISION SYMBOL 33615-10 DATE 08.24.17 ENGINEER J. HOUSEL CHECKED APPROVED APPROVED 04.08.11 TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 THOMPSON, WA SHEET E597 JOB NO. 11347785 COMP NO. DWG NO. 14-01 —E59 7 P8 Product Integration Center\_Drawings\14-01—E598.DWG I:\ES\Projects\17\171-062 RA SYM OUTDOOR OUTDOOR UNIT i IC14-1 /25,27 3/4"C, 2#10, #10GND TYP.) 3/4"C, 2#12, #12GND (TYP.) i 4.4 1C15.2-1/33 i 1C15.2-1/40 SURFACE MTD. i �a4 30AF/2P 25AT INDOOR UNIT PROJECTION STAND IC14-1 • 0 KVM MONITOR (MOUNTED AT CEILING OF THE BOX) (TYP) 13' U) cn 0 /10 CEILING MOUN ED 04-1/29,31 4"C. 4; 12.: 12G 1C4-1/3,26,28 3/4"C, 6#12, #12G 3D PRINTER 3-D PRINTER REVISION BY APPROVED DATE SYM REVISION E\ LARGE 1C 4-1/30 3/ "C, 2#12, #1 LCD MONI 1C15.2 -1 /19,21,41,42 3/4"C, 8#12, #12 GND TOR 1 + 18" 6 n n LCD I1IONITOR MONITOR (VIDEO WALL) +54" 10 5.2-1/13,15,2 3/ "C, 6#12 #12 GND 1 7 1C15.2-1/32 D 208Y/120V - 1ST FLOO PARTIAL DLA\ 1E61A E5.8 SCALE: 1/4" = 1'-0" BY APPROVED TABLE 30x60 J 30X70 MONITOR (VIDEO WALL +54" (TYP) A/V POWER +54" 0 DATE P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 37 1C15.2-1/37 1015.2-1 8' 4' 0 4' 8' 16' SCALE: 1/8"=1' -0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ,•;) 35276 Off'.??I STER� 4"ss'ONAL�1 VED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE LEGE\D: 14:c DUPLEX RECEPTACLE, 20A, 125V HUBBELL, 52621 =1 FLOOR BOX FSR, FL -500P, WITH (1) 20A DUPLEX OUTLET (1) DATA OUTLET, (1) A/V OUTLET JUNCTION BOX CONDUIT IN TRENCH NOTE: FIELD VERIFY MOUNTING HEIGHT AND EXACT LOCATION OF ALL RECEPTACLES FOR A/V EQUIPMENT WITH STAGEFRONT SHEETS PS100 & PS101 PRIOR TO ROUGH -IN. CO\STUCTIO \OT =S: PROVIDE AND INSTALL DUPLEX RECEPTACLE IN WALL. MOUNT RECEPTACLE AT +18" AFF. PROVIDE AND INSTALL FLOOR BOX. ROUTE (1) 1/2" CONDUIT VIA 6"WX6"D TRENCH. TRENCH PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE NEMA 3R, 30A RATED, FUSED EQUIPMENT DISCONNECT. MOUNT DISCONNECT TO EXTERIOR OF BUILDING AT +48" AFF. INSTALL LIQUID TIGHT TYPE METALIC FLEXIBLE CONDUIT FROM DISCONNECT SECONDARY TO THE EQUIPMENT. PROVIDE AND INSTALL IDENTIFICATION PLATE ON DISCONNECT SWITCH SHOWING DESIGNATION OF CIRCUIT SOURCE PANELBOARD THAT SUPPLIES POWER TO DISCONNECT AND EQUIPMENT IT IS FEEDING. EXISTING MECHANCIAL EQUIPMENT AND ITS ASSOCIATED WIRING DEVICES TO REMAIN. / PROVIDE CONDUIT, CONDUCTORS, BOXES, FITTINGS, AND ASSOCIATED HARDWARE. EXISTING RECEPTACLE TO REMAIN. PROVIDE AND INSTALL (1) 20A/2P CIRCUIT BREAKER IN POSITIONS 25, 27 AND (1) 20A/1P CIRCUIT BREAKER IN POSITIONS 29,26,28,30, 1,3,5 MATCH EXISTING TYPE AND AIC RATING. PROVIDE AND INSTALL (1) 20A/1P CIRCUIT BREAKER IN POSITIONS 13,15,17,19,21, 26,28,30. MATCH EXISTING TYPE AND AIC RATING. 10 EXSTING RECEPTACLE RE -CIRCUITED AS SHOWN. J -BOX FOR CONNECTION TO CRESTRON TOUCH PANEL. TERMINATION INTO TOUCH PANEL BY OTHERS. PROVIDE AND INSTALL FOURPLEX OUTLET. CONNECT TO EXISTING CIRCUIT AS SHOWN. RECEIVED CITY OF TUKWI 3 1 92 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 City of Tukwila UILDINC;4WISIONfim T EQUIPMENT SCHEDULE TAG NO. DESCRIPTION VOLT PHASE HP MCA WATTS REMARKS HP 1-2 INDOOR UNIT 208 1 1 30 1E69 CU 1-2 OUTDOOR UNIT 208 1 21 3.49 REVISION BY APPROVED DATE SYM REVISION E\ LARGE 1C 4-1/30 3/ "C, 2#12, #1 LCD MONI 1C15.2 -1 /19,21,41,42 3/4"C, 8#12, #12 GND TOR 1 + 18" 6 n n LCD I1IONITOR MONITOR (VIDEO WALL) +54" 10 5.2-1/13,15,2 3/ "C, 6#12 #12 GND 1 7 1C15.2-1/32 D 208Y/120V - 1ST FLOO PARTIAL DLA\ 1E61A E5.8 SCALE: 1/4" = 1'-0" BY APPROVED TABLE 30x60 J 30X70 MONITOR (VIDEO WALL +54" (TYP) A/V POWER +54" 0 DATE P-8 PRODUCT INTEGRATION CENTER 33615-10 CASNE MN 08.24.17 37 1C15.2-1/37 1015.2-1 8' 4' 0 4' 8' 16' SCALE: 1/8"=1' -0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ,•;) 35276 Off'.??I STER� 4"ss'ONAL�1 VED BY DEPT. DATE DRAWN DATE CHECKED SUBTITLE LEGE\D: 14:c DUPLEX RECEPTACLE, 20A, 125V HUBBELL, 52621 =1 FLOOR BOX FSR, FL -500P, WITH (1) 20A DUPLEX OUTLET (1) DATA OUTLET, (1) A/V OUTLET JUNCTION BOX CONDUIT IN TRENCH NOTE: FIELD VERIFY MOUNTING HEIGHT AND EXACT LOCATION OF ALL RECEPTACLES FOR A/V EQUIPMENT WITH STAGEFRONT SHEETS PS100 & PS101 PRIOR TO ROUGH -IN. CO\STUCTIO \OT =S: PROVIDE AND INSTALL DUPLEX RECEPTACLE IN WALL. MOUNT RECEPTACLE AT +18" AFF. PROVIDE AND INSTALL FLOOR BOX. ROUTE (1) 1/2" CONDUIT VIA 6"WX6"D TRENCH. TRENCH PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE NEMA 3R, 30A RATED, FUSED EQUIPMENT DISCONNECT. MOUNT DISCONNECT TO EXTERIOR OF BUILDING AT +48" AFF. INSTALL LIQUID TIGHT TYPE METALIC FLEXIBLE CONDUIT FROM DISCONNECT SECONDARY TO THE EQUIPMENT. PROVIDE AND INSTALL IDENTIFICATION PLATE ON DISCONNECT SWITCH SHOWING DESIGNATION OF CIRCUIT SOURCE PANELBOARD THAT SUPPLIES POWER TO DISCONNECT AND EQUIPMENT IT IS FEEDING. EXISTING MECHANCIAL EQUIPMENT AND ITS ASSOCIATED WIRING DEVICES TO REMAIN. / PROVIDE CONDUIT, CONDUCTORS, BOXES, FITTINGS, AND ASSOCIATED HARDWARE. EXISTING RECEPTACLE TO REMAIN. PROVIDE AND INSTALL (1) 20A/2P CIRCUIT BREAKER IN POSITIONS 25, 27 AND (1) 20A/1P CIRCUIT BREAKER IN POSITIONS 29,26,28,30, 1,3,5 MATCH EXISTING TYPE AND AIC RATING. PROVIDE AND INSTALL (1) 20A/1P CIRCUIT BREAKER IN POSITIONS 13,15,17,19,21, 26,28,30. MATCH EXISTING TYPE AND AIC RATING. 10 EXSTING RECEPTACLE RE -CIRCUITED AS SHOWN. J -BOX FOR CONNECTION TO CRESTRON TOUCH PANEL. TERMINATION INTO TOUCH PANEL BY OTHERS. PROVIDE AND INSTALL FOURPLEX OUTLET. CONNECT TO EXISTING CIRCUIT AS SHOWN. RECEIVED CITY OF TUKWI 3 1 92 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2011 City of Tukwila UILDINC;4WISIONfim T T _ 1E60A 1E6OB 1E61A 1E61B 1E62 1E63 1E64 1E65 —H 1E67 1E68 1E69 1E66 A PERIVMIT CENTER ISSUE FOR CONSTRUCTION CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 171-062 AUGUST 24, 2017 208Y/120V 1ST FLOOR PARTIAL PLAN CURRENT REVISION SYMBOL 33615-10 DATE 08.24.17 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER P-8 PRODUCT INTEGRATION CENTER BUILDING 14-01 COL. 12.4/16 THOMPSON, WA SHEET E598 JOB NO. COMP NO. DWG NO. 14-01-E598 AV .00V SC-EIULE ROOM NUMBER ROOM NAME ROOM TYPE DISPLAY TYPE DISPLAY SIZE 11B14 EQUIPMENT ROOM AV RACK ROOM 11B15 VOCATIONAL LEARNING MULTIPURPOSE ROOM PROJECTION AV X00 V Sc SCALE: NTS • MULE � PS001 LEG GE\ HAL \OTES HFEH\CE D AWI\GS CO \STUCTIO\ \OTES RECEIVED CITY OF TUKWILA f4` PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION PRESENTATION SYSTEMS 6 SOUTHERN OAKS DR. SAVANNAH, GA. 31405 PH. 912-236-1345 FAX 912-233-5350 www.sfps.net SYM REVISION A DESIGN BY ATL APPROVED DATE SYM REVISION BY APPROVED DATE CTS 07.11.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ATL DATE 06.26.17 CHECKED SUBTITLE AV ROOM SCHEDULE CURRENT REVISION SYMBOL A DATE 07.11.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE AV MASTER PIC DESIGN BUILDING 14-01 SEATTLE, WA SHEET PS001 JOB NO. COMP NO. DWG NO. 14-01—PS001 17 rQ.,I 10 V ROOM 11B1/1 Erg": 13 > 1 11 :0 105(71 12 — commiL i — z 1 11 4 h, • PS100 PS101 goo v 12B1�I 'C >19 3 FIDE A PS100IPS101 TYPICAL AV PLA\ SCALE: 3/8"=1 '-0" PS 100 C ASE 1L315 le It VOCATO\AL 17> 7 > 0 JA T0� 13R15 v 12315 DIVISION 26 TO PROVIDE (1) 20A 200VAC RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 18" AFF BEHIND PROJECTION STAND. ROUTE (1) 1-1/4" CONDUIT FROM BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. REQUIRES VADDIO 999-2225-015 RECESSED MOUNTED FLUSH IN WALL BY DIVISION 26. 1-1/4" CONDUIT FROM AV FLOORBOX STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. DOOR TO BE REMOVED 2 GANG BACK BOX MOUNTED FLUSH IN WALL AT 54" AFF BESIDE VIDEO WALL. BACK BOX PROVIDED AND INSTALLED BY DIVISION 26. RIGID SCREEN RECESSED IN WALL. 20 ALL CONDUIT SHOWN ON PLAN IS TO BE EMPTY LOW VOLTAGE CONDUIT WITH PULL STRING. E.C. TO PROVIDE SIZE & QUANTITY INDICATED. LINE DOES NOT IMPLY HOW CONDUIT IS TO BE ROUTED. ROUTE CONDUIT ALONG SHORTEST PATH AS REQUIRED IN FIELD. WHERE STUB SYMBOL SHOW, CONDUIT IS TO BE STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING IN ROOM WHERE SYMBOL IS SHOWN, UNLESS NOTED OTHERWISE. 21 POWER AND DATA CONNECTIONS SHOWN ARE FOR REFERENCE ONLY. REFER TO PO COMMUNICATIONS FLOOR PLANS FOR EXAC LOCATIONS OF POWER AND DATA RECEPTA SYM A REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DESIGN ATL CTS 07.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ATL CHECKED DATE 06.26.17 THi 1 A17D FOR A`Na COMPLIANCE QUANT FAT" VED LES. NOV 2120» City of Tukwila BUILDING DIVISION LEGE\D CI\HAL \OYES FIXED REAR PROJECTION SCREEN MOUNTED IN WALL. VIDEO WALL MOUNTED TO WALL. LCD MONITOR MOUNTED TO WALL. CISCO SPEAKERTRACK 60 BY OWNER. WORKSTATION ACCESS PLATE. >EQUIPMENT RACK TRANSMITTER DEVICES MOUNTED UNDER TABLE. 8 >CRESTRON TOUCH PANEL. gSTATIONARY TOUCH TABLE WITH DELL DIMENSION OPTIPLEX PC. BY OWNER. 110 )'KVM MONITOR MOUNTED IN SHADOWBOX. FLOORBOX UNDER TABLE. CISCO P60 CAMERA BY OWNER. REAR PROJECTION MIRROR SYSTEM. 14 INTERACTIVE OVERLAY MOUNTED ON VIDEO WALL. INTERACTIVE CAMERA SYSTEM BY OWNER. 16 >PROJECTOR ACCESS PLATE. EFEH\CE D�AWI\GS CO\ STS U CTI O \ \OTES DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 66" AFF BEHIND MONITOR. MONITOR REQUIRES BLOCKING IN WALL TO SUPPORT 150LBS. DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 54" AFF BEHIND MONITOR. MONITOR REQUIRES BLOCKING IN WALL TO SUPPORT 150LBS. 1-1/4" CONDUIT FROM CAMERA BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. 1-1/4" CONDUIT FROM MONITOR BACK BOX TO CAMERA BACK BOX. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX MOUNTED FLUSH IN WALL AT PROJECT RECEPTACLE HEIGHT. BACK BOX PROVIDED AND INSTALLED BY DIVISION 26. 1-1/4" CONDUIT FROM WORKSTATION BACK BOX STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. 2 GANG BACK BOX MOUNTED FLUSH IN WALL AT 54" AFF BESIDE VIDEO WALL. BACK BOX PROVIDED AND INSTALLED BY DIVISION 26. DIVISION 26 TO PROVIDE SHADOW BOX FOR KVM MONITOR, (1) 20A 120VAC RECEPTACLE, AND (1) SINGLE GANG BACK BOX RECESSED FLUSH IN SHADOWBOX. DIVISION 27.20 TO PROVIDE (1) DATA DROP BEHIND MONITOR. FSR FL -500P FLOOR BOX MOUNTED IN FLOOR BY DIVISION 26. REQUIRES (1)20A 120VAC RECEPTACLE AND (1) 1-1/4" CONDUIT STUBBED INTO ACCESSIBLE AREA ABOVE CEILING IN ROOM WHERE SYMBOL IS LOCATED. REQUIRES (1) NETWORK DROP FOR AV USE PROVIDED BY DIVISION 27.20. SEE ELECTRICAL DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS. EQUIPMENT RACK BACK BOX. DIVISION 26 TO PROVIDE 6"x6"x3" SCREW COVER BOX RECESSED 18" AFF. STUB (2) 1-1/4" CONDUIT FROM BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE BUSHINGS AND PULL STRING WITH CONDUITS. RACK REQUIRES (3) 20A DUPLEX RECEPTACLES PROVIDED BY DIVISION 26. DIVISION 27.20 TO PROVIDE (5) NETWORK DROPS MOUNTED IN WALL BEHIND RACK. 1" CONDUIT FROM RECESSED CAMERA BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 76-1/2" AFF BEHIND MONITOR. MONITOR REQUIRES BLOCKING IN WALL TO SUPPORT 150LBS. RECEIVED CITY OF TUKWILA T312A PERMIT CENTER SUBTITLE AV FLOOR PLAN CURRENT REVISION PRESENTATION SYSTEMS 6 SOUTHERN OAKS DR. SAVANNAH, GA. 31405 PH. 912-236-1345 FAX 912-233-5350 www.sfps.net SYMBOL DATE 07.31.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE AV MASTER PIC DESIGN BUILDING 14-01 SEATTLE, WA SHEET PS100 JOB NO. COMP NO. DWG NO. 14-01-PS100 8 > 18 10 10 10 1 10 POJECTIO\ SCALE: 1 /4"=1'-0" WALL AV LAYOUT � PS101 POWER AV CD 13 AV POWER , DATA POJECTIO\ WALL I\RAS-RUCTUE LAYOUT (B SCALE: 1/4"=1'-0" VIDEO WALL AV LAYOUT � SCALE 1/4"=1'-0" -\--POWER AV 15 VIDEO WALL I\F SCALE 1/4"=1'-0" PS101 POWER AV POWERAV POWER AV POWER AV AV POWER N AS-RUCTUE LAYOUT r Psioi 1!5 POWER �- DATA AV AV DATA AV POWER - I __ _ •': — dig , , 1,,, 1 -- 1 AV EQUIPME\T AC nPAS-Rucru SCALE: 1/4"=1'-0" AV EQUIPN SCALE: 1 /4"=1'-0" " 0 E\T QAC 12 < AV LAYOUT �1 2'-4" SHADOW 30X DISPLAY DETIALS n SCALE: 1/2"=1'-0" PS 101 LAYOUT � cs,oi BLOCKING BY OTHERS. IF STUD DOES NOT FALL AT CENTER OF MOUNTING LOCATION, BLOCK 5 BAYS AS REQUIRED TO PROVIDE A MINIMUM BACKING WIDTH OF 32" ON EACH SIDE OF THE CENTER OF MOUNTING LOCATION. BLOCKING TO SUPPORT 700LBS. FSR FL -500P FLOOR BOX MOUNTED IN FLOOR BY DIVISION 26. REQUIRES (1)20A 120VAC RECEPTACLE AND (1) 1-1/4" CONDUIT STUBBED INTO ACCESSIBLE AREA ABOVE CEILING IN ROOM WHERE SYMBOL IS LOCATED. REQUIRES (1) NETWORK DROP FOR AV USE PROVIDED BY DIVISION 27.20. SEE ELECTRICAL DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS. 18 ALL CONDUIT SHOWN ON PLAN IS TO BE EMPTY LOW VOLTAGE CONDUIT WITH PULL STRING. E.C. TO PROVIDE SIZE & QUANTITY INDICATED. LINE DOES NOT IMPLY HOW CONDUIT IS TO BE ROUTED. ROUTE CONDUIT ALONG SHORTEST PATH AS REQUIRED IN FIELD. WHERE STUB SYMBOL SHOW, CONDUIT IS TO BE STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING IN ROOM WHERE SYMBOL IS SHOWN, UNLESS 19 POWER AND DATA CONNECTIONS SHOWN 0 ARE FOR REFERENCE ONLY. REFER TO PO COMMUNICATIONS FLOOR PLANS FOR EXACT LOCATIONS OF POWER AND DATA RECEPTAC FOR I uzJ po1PLIANCE ER ANEPtPPROVED QS ANTj(V A21 2017 City of Tukwila BUILDING DIVISION LECENG GE \PAL \OTES FIXED REAR PROJECTION SCREEN MOUNTED IN WALL VIDEO WALL MOUNTED TO WALL. LCD MONITOR MOUNTED TO WALL. 4 SHADOW BOX FOR KVM MONITOR. FLIP UP KEYBOARD AND MOUSE TRAY. 6 >CISCO SPEAKERTRACK 60 BY OWNER. WORKSTATION ACCESS PLATE. 8 >CEILING SPEAKER. 9 >CISCO CEILING MICROPHONE BY OWNER. 10 >RECESSED CAMERA MOUNT. CAMERA BY OWNER. FLOOR BOX UNDER TABLE. PROJECTION SCREEN MOUNTED IN WALL. ® PROJECTOR MOUNTED IN MIRROR SYSTEM. 'EFHE\CE DRAWI GS CO\SRUCTh3\ \OTES DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 66" AFF BEHIND MONITOR. MONITOR REQUIRES BLOCKING IN WALL TO SUPPORT 150LBS. DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 54" AFF BEHIND MONITOR. MONITOR REQUIRES BLOCKING N WALL TO SUPPORT 250LBS. CAMERA REQUIRES 2 GANG BACK BOX RECESSED FLUSH 54" AFF BY DIVISION 26. DIVISION 26 TO ROUTE (1) 1-1/4" CONDUIT FROM CAMERA BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. DIVISION 26 TO PROVIDE SHADOW BOX FOR KVM MONITOR, (1)20A 120VAC RECEPTACLE, AND (1) SINGLE GANG BACK BOX RECESSED FLUSH IN SHADOWBOX. PROVIDE 1" CONDUIT FROM BACK BOX TO CAMERA BACK BOX. PROVIDE CONDUIT WITH PULL STRING AND PUSHING. DIVISION 27.20 TO PROVIDE (1) DATA DROP BEHIND MONITOR. REQUIRES INNOVATION FIRST INTERNATION 104-2795 KEYBOARD TRAY. RIGID PROJECTION SCREEN RECESSED IN WALL. 2 GANG CAMERA BACK BOX MOUNTED FLUSH IN WALL AT 86" AFF. BACK BOX PROVIDED AND INSTALLED BY DIVISION 26. 1-1/4" CONDUIT FROM MONITOR BACK BOX STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. BLOCKING BY OTHERS. IF STUD DOES NOT FALL AT CENTER OF MOUNTING LOCATION, BLOCK 5 BAYS AS REQUIRED TO PROVIDE A MINIMUM BACKING WIDTH OF 32" ON EACH SIDE OF THE CENTER OF MOUNTING LOCATION. BLOCKING TO SUPPORT 150LBS. EQUIPMENT RACK BACK BOX. DIVISION 26 TO PROVIDE 6"x6"x3" SCREW COVER BOX RECESSED 18" AFF. STUB (2) 1-1/4" CONDUIT FROM BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE BUSHINGS AND PULL STRING WITH CONDUITS. RACK REQUIRES (3) 20A RECEPTACLES PROVIDED BY DIVISION 26. DIVISION 27.20 TO PROVIDE (5) NETWORK DROPS MOUNTED IN WALL BEHIND RACK. 1" CONDUIT FROM RECESSED CAMERA BOX STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. REQUIRES VADDIO 999-2225-015 RECESSED MOUNTED FLUSH IN WALL BY DIVISION 26. DIVISION 26 TO PROVIDE (1) 20A 200VAC RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH IN WALL 18" AFF BEHIND PROJECTION STAND. ROUTE (1) 1-1/4" CONDUIT FROM BACK BOX TO ACCESSIBLE SPACE ABOVE CEILING. PROVIDE CONDUIT WITH PULL STRING AND BUSHING. DIVISION 26 TO PROVIDE (1) 20A 120VAC QUADRUPLEX RECEPTACLE, & (1) 2 GANG BACK BOX RECESSED FLUSH AT PROJECT RECEPTACLE HEIGHT. RECEIVED CITY OF TUKWILA 1' °7 PERMIT CENTER PRESENTATION SYSTEM 6 SOUTHERN OAKS DR. SAVANNAH, GA. 31405 PH. 912-236-1345 FAX 912-233-5350 www.sfps.net SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A DESIGN ATL CTS 07.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ATL DATE 06.26.17 CHECKED SUBTITLE AV LAYOUT PLAN CURRENT REVISION SYMBOL DATE A 07.31.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE AV MASTER PIC DESIGN BUILDING 14-01 SEATTLE, WA SHEET PS101 JOB NO. COMP NO. DWG NO. 14-01-PS101 0 F 0 DEFLECTED C SCALE: 3/8"=1'-0" EQJID 0 V 0 V \T 1 1 B 1 /1 OV 1 2 6'1 / 0 0 VCCA11 0\AL 0 0 0 (-7 11315 0 0 0 0 -1L1\G DLA\ rA� PS102 0 0 0 JA\T0� 13315 12B15 LEGE J G CEILING SPEAKER \HAL SAL \ OTES CISCO CEILING MIC BY OWNER. IEEE E\CE D AWI \GS CO\STUCTIO\ \OTES REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 3 1 L" PERMIT CENTER PRESENTATION SYSTEMS 6 SOUTHERN OAKS DR. SAVANNAH, GA 31405 PH. 912-236-1345 FAX 912-233-5350 www.sfps.net REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DESIGN ATL CTS 07.11.17 a ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ATL DATE 06.26.17 CHECKED SUBTITLE RCP CURRENT REVISION SYMBOL A DATE 07.11.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE AV MASTER PIC DESIGN BUILDING 14-01 SEATTLE, WA SHEET PS102 JOB NO. COMP NO. DWG NO. 14-01-PS102