Loading...
HomeMy WebLinkAboutPermit D17-0302 - HARRY'S OF ALLENTOWN - WEDGE AWNINGHARRY'S OF ALLENTOWN 12404 42 AVE S D17-0302 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 0179003238 Permit Number: D17-0302 12404 42ND AVE S Project Name: HARRY'S OF ALLENTOWN Issue Date: 12/19/2017 Permit Expires On: 6/17/2018 Owner: Name: Address: Contact Person: Name: LUKE WALKER Address: 18375 OLYMPIC AVE S , TUKWILA, WA, 98188 HARRIS & SUCKIE PROPERTIES 10529 SE 213TH ST , KENT, WA, 98031 Contractor: Name: RAINIER INDUSTRIES LTD Address: 18375 OLYMPIC AV S , TUKWILA, WA, 98188 License No: RAINIIL066QP Lender: Name: RAINIER INDUSTRIES Address: 18375 OLYMPIC AVE S, TUKWILA, WA, 98188 Phone: (425) 981-1214 Phone: (425) 251-1800 Expiration Date: 1/11/2019 DESCRIPTION OF WORK: 1 EACH WEDGE AWNING WITH STANDING SEAM METAL ROOFING. APPROXIMATELY 54'(W) X 3' (H) X 5' (D) WITH 2" TRUSS FORMING CORNER Project Valuation: $17,960.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $795.96 Occupancy per IBC: U Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 1-441(?_ Date: 121(0 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 4046 SI-EPDXY/EXP CONC 4025 SI -STEEL CONST CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Building Permit No. V1—.01.02 Project No. Date Application Accepted: 1,1"-S-1 7 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 12404 42ND Ave S King Co Assessor's Tax No.: 0179003238 Suite Number: Tenant Name: Harry's of Allentwon PROPERTY OWNER Name: Harold Harris Address: 22408 95th CT S City: Kent State: WA Zip: 98031 CONTACT PERSON — person receiving all project communication Name: Luke Walker Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (425) 981-1214 Fax: Email: lukew@rainier.com GENERAL CONTRACTOR INFORMATION Company Name: Rainier Industries Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (425) 251-1800 Fax: Contr Reg No.: RAINIIL066QP Exp Date: 01/11/2019 Tukwila Business License No.: BUS -0100320 H:\Applications\Fors-Applications On Line \201 1 Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh New Tenant: Floor: ❑ Yes I..No ARCHITECT OF RECORD Name: Rainier Industries Company Name: Rainier Industries Company Name: Engineer Name: Thomas Swanson Architect Name: City: Tukwila State: WA Address: Phone: (425) 981-1214 Fax: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Rainier Industries Company Name: Rainier Industries City: Tukwila State: WA Zip: 98188 Engineer Name: Thomas Swanson Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (425) 981-1214 Fax: Email: thomass@rainier.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Rainier Industries Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 17,960 Existing Building Valuation: $ 290,100 Describe the scope of work (please provide detailed information): 1 ea wedge awning with standing seam metal roofing - Approx Dims - 54' (w) 3' (h) x 5' (d) w/ 2" truss forming corner Will there be new rack storage? El Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forts-Applications On Line \201 1 Applications\Pertnit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 2,400 162 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forts-Applications On Line \201 1 Applications\Pertnit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: n"�` Luke Walker t°*`,biLae .+ Signature: ;' m:cm,r.uonae.naro Date: Print Name: Luke Walker Day Telephone: (425) 981-1214 Mailing Address: 18375 Olympic Ave S Tukwila WA 98188 City State Zip H:\Applicatima\Fomes-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $795.96 D17-0302 Address: 12404 42ND AVE S Apn: 0179003238 $795.96 Credit Card Fee $23.18 Credit Card Fee R000.369.908.00.00 0.00 $23.18 DEVELOPMENT $750.18 PERMIT FEE R000.322.100.00.00 0.00 $451.93 PLAN CHECK FEE R000.345.830.00.00 0.00 $293.75 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12727 R000.322.900.04.00 0.00 $22.60 $795.96 Date Paid: Friday, November 03, 2017 Paid By: IAN MAYTHER Pay Method: CREDIT CARD 053346 Printed: Friday, November 03, 2017 3:06 PM 1 of 1 CISYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. " PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 D) , -0-362_, 6300 0Via- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: i �RyS 6ic 41-1-0Tb C Type of Inspection: i Bt11L/NC- rtil-l— Address: /2 ya 4 42ND Av • Date Called: Special Instructions: Date Wanted: a, dZ"-'2--(CP--/ES p;m. Requester: PowALLD IA BLD Asti f,S' Phone No: 20&– / — Des fApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: lS(— S7 Xi -KV t_ (tA CCK - �i% CX,"ri✓614:✓ ulie/t 04<- 23tJ/Lj/11 - --701-4--- ii L --- 1 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing RECEIVED CITY OF TUKWILL FEB 2 2 2018 Job Number: 18-0085 PERMIT CENTEP PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT Report Number: 346009 Permit Number: D17-0302 Project: Tukwila Awning Client: Rainier Industries, Ltd. Address: 12404 42nd Avenue South, Tukwila Address: 18375 Olympic Avenue South, Tukwila Inspector: Steven Moser Date: 2/07/2018 Description/Location: Arrived on site as requested to inspect proper installation of adhesive proprietary anchors for future awning spanning, west side of the building and above the window on the north side of building as per upper attachment detail M on page P4. Intended Use: Awning attachment Building Code & Year: IBC 2015 Reinforcing Steel All Thread Bar/Dowel Size & Quantity: Anchor Size & Quantity: 3/8" (27) Rebar Manufacturer: Rebar Grade: 0 40 0 60 0 Other: Type of Bar: 0 A-615 0 A-706 0 A-775 0 Other: Special Ductile Quality (SDQ): Anchor Length: 5 1/8" Hole Diameter: 5/8" ❑ Yes ❑ No Type of Steel (ASTM): ® A-36 0 F-1554 0 A-307 Grade: ® 36 0 50 0 75 0 Other: Hole Depth: 4 Ya"- 6 %" Concrete Thickness: N/A Hole Orientation: ❑ Vertical Down 0 Vertical Up ® Horizontal Required Embedment: 4" Concrete Strength: N/A Base Material: 0 Normal Weight Concrete 0 Light Weight Concrete 0 CMU ® Brick 0 Composite Deck Hole Cleaning: El Compressed Air ❑ Hand Pump 0 Other: Brushed: El Yes 0 No Compressed Air PSI: 95 Hole Condition: ® Dry 0 Damp 0 Water Saturated 0 Submerged Drill Bit (ANSI B212.15): 0 Yes 0 No Adhesive Type: Hilti Hit HY 70 Weather: Overcast Approved Diamond Cored Hole: 0 Yes 0 No N/A Expiration Date: 05/2018 Ambient Temperature: 56° Comments All construction inspected was completed in conformance with approved project documents and manufacturers recommendations. Reference Standard(s) Used: Conforms X Does Not Conform ICC ESR #: 2685/3342 Substrate Temperature: 52° Copies to: Client X Engineer Owner X Contractor Architect X Building Dept. Others Technical Responsibility: I , -2- f 1 g Isaac Ruoff,Project anager Thls report applies only to the Items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221 Form No.: ADMIN -86-02 (Rev. 05/13) 1 2 3 4 5 REVISIONS No changes shall he made to the scope of work witho i, i. prior approval of Tukwila!cling Division. NOTE: Revisions will require a nsw plan submittal and may include additional plan review fees GENERAL NOTES 1. These drawings have been prepared primarily to safeguard against major structural damage and loss of life, not to limit damage or maintain function -as per requirements of the current accepted building code as listed in the Basis for Design. 2. An experienced licensed contractor with a working knowledge of applicable codes and industry accepted standard practices shall perform the work depicted in these drawings. 3. All work shall conform to the minimum standards of the current governing building code and industry specific specifications and standards. The contractor shall comply with requirements of all regulatory agencies with authority over any portion of the work. Work not explicitly shown on these drawings shall conform to all applicable codes and accepted standard practices. 4. The contractor shall verify all dimensions, elevations and conditions on these drawings with the architectural and all other discipline drawings prior to start of construction. Notify architect or EOR in writing before the start of construction regarding discrepancies, omissions or variations, or they shall become the sole responsibility of the contractor. Notes and the specific details on these drawings take precedence over general structural notes and typical details. 5. Construction methods are not indicated on these drawings. The contractor shall be solely responsible for all methods, sequences and procedures of construction. The contractor shall provide adequate shoring, bracing, formwork, etc. as required for the protection of life and property during construction. 6. Openings, pockets, etc. larger than 6 inches shall not be placed in structural members unless specifically detailed on these drawings. When drawings by others show items in structural members not shown on the structural drawings, notify the engineer in writing to determine correct disposition. 7. Site visits by the EOR are a resource for the contractor and shall not be considered as special inspections. 8. General inspection and special inspection shall be performed during construction as required by the local governing municipality. BASIS FOR DESIGN 1. Goveming Building Code: 2015 International Building Code 2. Risk Category: II 3. Roof Loads: Dead Load = self weight + 2.0 psf misc. dead load Live Load = 20 psf Snow Load = 25 psf (minimum required snow load) 4. Wind Design: Basic Wind Speed = 110 mph Wind Exposure = D Risk Catagory II Mean Roof Height = less than 15'-0" 5. Seismic Design: Wind loads govem lateral structural design. FILE COPY Perm!t No. ik1 .M Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted cods or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Ey: C fki 7 . if Date: / ?_/tit' 1-61/7 City of Tukwila BUILDING DINMSIC3N ISEF`:-.'.TE R_: 7;:Ct'i:..;;ical �,,f Electric J lel P;umb:ng L......_ t!9 Gcs Piping a:::./ of TL:' VVit3 Bt.m_Dr ' a r 1vISioN SPECIAL INSPECTIONS (STEEL CONSTRUCTION) It shall be the contractors' responsibility to ensure special inspections have been provided and documented. It shall be the contractors' responsibility to contact the registered design professional in responsible charge and request for all required special inspection documentation with inspections tables for this project. The owner or the registered design professional in responsible charge acting as the owner's agent shall employ one or more approved agencies to perform inspections during construction on the types of work listed. 1705.2 Steel construction. Special inspection for structural steel shall be in accordance with the quality assurance inspection requirements of AISC 360. Special inspection construction other than structurai steel accordance with Table 1705.2.2. for steel shall be in (('��((��REVIEW1 D FOR CODE COMPLIANC APPROVED DEC 0 7 2017 7 8 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR p1)-- STRUCTul2l�L /�f T�kwlia 1. All alum L i�y . rrt r%uir$6(96`1'-T with minimum tensile yield stress 35 ksi, U.N.O. 2. All aluminum welds shall conform to current aluminum specifications. 3. Aluminum parts shall be welded with an inert gas shielded arc or resistance welding process. No we processthat requires a welding flux shall be used. Only filler alloys complying with the governing code a specifications requirements shall be used. 4. All welds of structural members shall be performed by welders qualified in accordance with the governing code procedures. 5. Welding of aluminum shall be in accordance with nationally recognized standards. 6. Oxygen cutting of aluminum alloys shall not be permitted. 7. Where aluminum alloy parts are in contact with dissimilar metals (other than stainless, aluminized or galvanized steel) or absorbent building materials likely to be continuously or intermittently wet, the faying surfaces shall be painted or otherwise separated in accordance with the current aluminum specifications. 8. During erection, structural aluminum shall be adequately braced and fastened to resist dead, wind and erection loads. FASTENERS 1. Screws shall be self -tapping hex head sheet metal screws with current ICBO/ICC rating for material into which installation occurs. 2. Screws which are removed shall be replaced with a larger diameter screw where replacement is made into an existing hole. Replace all screws which strip out material. 3. Screws shall be spaced no closer than 5/8" o.c. and maintain a minimum free edge distance of 1/2", U.N.O. 4. Clip angles or flat clips used for attachment shall be a minimum of 33 mils, U.N.O. Size all clip angles and flat clips to maintain minimum screw spacing and edge distances as noted above. 5. All screws #8 and larger shall have a minimum head size of 5/16". All screws shall have sufficient length to ensure penetration into aluminum/steel by at least (2) full diameter threads. 6. All screws shall be a minimum of #8 self -tapping screws, U.N.O. 7. All anchors installed into concrete shall be Hilti KB TZ expansion anchors (ESR -1917) or Hilti HIT -RE 500 -SD adhesive anchors (ESR -2322). All anchors installed into CMU shall be Hilti KB III expansion anchors (ESR - 1385) or Hilti HIT-HY 70 adhesive anchors (ESR -2682). Approved equivalent anchors with current ICBO/ICC reports may be used at the contractor's discretion. 8. All bolts shall be installed as bearing -type connections with threads excluded from shear plane (type "x" connection), U.N.O. High-strength bolts shall be snug tightened using any AISC approved method and do not require special inspections unless noted otherwise. All bolts in slotted or oversize holes and all high-strength bolts shall be installed with washers. 12.05.2017 CORRECTION SPECIAL INSPECTION TR 1. All required special inspections shall be performed in accordance with the current accepted building code Check with the local building department for required special inspections. 2. The special inspector shall be a qualified person who shall demonstrate competence, to the satisfaction of the local building department, for the inspection of the particular type of construction or operation requiring special inspection. 3. The special inspector shall inspect the work assigned for conformance with the approved contract drawings and specifications. The special inspector shall fumish inspection reports to the local building department, the EOR and other designated persons required by the governing building official. All discrepancies shall be brought to the immediate attention of the contractor for correction, and then if uncorrected in a reasonable period of time, the EOR and the building official shall be notified. The special inspector shall submit a final �we'��D signed report stating whether the work requiring special inspection was, to the best of the inspectors know) (BGG constructed in conformance with the approved plans and specifications and the applicable building provisions 4. Inspectors shall inspect from an approved set of contract drawings, shop drawings shall not be used in lie•Lree 0 2011 the approved contract drawings for inspection purposes. 5. Certificate of approval regarding materials and inspection of prefabricated items shall be provided in TY OF TUKWILA accordance with the current accepted building code. br7o3oz PERMIT CENTER STANDING SEAM AWNING .X=±1/4" .XX = ± 1/16" ANGLES =± 1° HARRIS PROPERTY MANAGEMENT ENGINEERING NOTES RAINIER 1 RAINIER INDUSTRIES LTD N/APta 394166-1-1 PO.5 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT\394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1.1 - PACK AND GO\ 1 2 3 4 5 6 7 8 24 GAUGE NRM 1000 ROOFING PANELS REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR FUNCTION: TO PROVIDE COVER NOTES: ORIGINAL DESIGN CONCEPTS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAWS AND ARE THE PROPERTY OF RAINIER INDUSTRIES, LTD. ANY REPRODUCTION OF THIS DESIGN CONCEPT WITHOUT WRITTEN CONSENT IS EXPRESSLY FORBIDDEN. FRAME #1 DELIVERABLES DESCRIPTION QTY STANDING SEAM WEDGE AWNING AROUND CORNER (3 FRAMES) 1 FRAME BREAK #1 FRAME#2 FRAME BREAK #2 ISOMETRIC VIEW OF 394166-1-1 - ASSEMBLY TEMPLATE R1 QTY (1) FRAME #3 12.05.2017 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila BUILDING DIVISION , RECEIVED CITY OF TUKWILA DEC 0 6 2011 PERMIT CENTER SHEET INDEX PAGE SHEET DESCRIPTION DEPARTMENT P1 SCOPE OF WORK P2 PLOT PLAN P3 ELEVATION VIEW P4 ELEVATION VIEW CONTINUED P5 ISOMETRIC CUT LIST FRAME #1 P6 FRAME DETAIL FRAME #1 M P7 ISOMETRIC CUT LIST FRAME #2&3 M P8 FRAME DETAIL FRAME #2&3 M P9 ROOFING PANLES PART DESCRIPTION STANDING SEAM AWNING .X .± 1/4" .XX =± 1/16" ANGLES = ± 1° HARRIS PROPERTY MANAGEMENT SCOPE OF WORK Cr'S'Aa) RAINIER INDUSTRIES LTD o N/A". 394166-1.1 PAGE P1 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT\ 394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\ DRAWING 1394166-1-1 - PACK AND GO\ 8 PAD - 0 w REVISION HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 11/28/2017 FUNCTION: PROVIDE COVER NOTES: ORIGINAL DESIGN CONCEPTS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAWS AND ARE THE PROPERTY OF RAINIER INDUSTRIES, LTD. ANY REPRODUCTION OF THIS DESIGN CONCEPT WITHOUT WRITTEN CONSENT IS EXPRESSLY FORBIDDEN. S 124th St S 124th St 19'-0° 4th St entown Superen PARCEL# 0179003238 12404 42nd Avenue South \—PropertyLine S 124th St S 124th St Plot Plan Standing Seam Awning Scale: 1/32" = 1'-0" S\ DEVELOPMENT\ Harris Property Management\394166 - Standing Seam wedge awning \394166-1-1 - 1 Ea standing seam Wedge Awning \ Drawing \394166-1-1- Harris Property Management - Permit DWG - R1.dwg, 11/29/2017 8:14:51 AM, Adobe PDF 12.05.2017 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 062017 PERMIT CENTER STANDING SEAM AWNING .X=±1/4" .XX = t 1/16° ANGLES=±1° HARRIS PROPERTY MANAGEMENT PLOT PLAN RA N GR RAINIER INDUSTRIES LTD Pw�xPA / N/A 394166-1.-1 P2 1 4 5 6 7 8 A �---1 1 A -• ' 0` FRONT VIEW OF 394166-1-1 - ASSEMBLY TEMPLATE R1 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR /FRAME BREAK #1 SECTION A -A 1/4" X 1" TEK SCREW METAL ROOFING 3/8" X 2.5" S.S THRU BOLT 24" O.C. MAX FRAME BREAK#2 FRAME BREAK DETAIL VIEW QTY (7 PER FRAME BREAK) 2 FRAME BREAKS "X1" PURLIN FOR ROOFING ROOFING ATTACHMENT DETAIL J 3/8" WASHER 1 EVERY BOLT 3/8" LOCK NUT 1 EVERY BOLT REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 062017 PERMIT CENTER 12.05.2017 STANDING SEAM AWNING .X = ± 1/4" .XX=±1/16" ANGLES =± 1° HARRIS PROPERTY MANAGEMENT ELEVATION VIEW RA NIGR RAINIER INDUSTRIES LTD Rai. MT " N/A 394166-1-1 P3 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT 394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ A� FRONT VIEW OF 394166-1-1 - ASSEMBLY TEMPLATE R1 W SECTION A -A PPER ATTACHMENT UPPER CORNER DETAIL R FRAME #1 & #2 FOR ATTACHMENT NEAR CORNER 1" SINGLE HOLE Z-BRAKCET 3/8" LOCK NUT 3/8" THREADED ROD WITH HILTI HY70 EPDXY MIN EMB 4" 1/4" X 1"TEK SCREW 1"X1" BOTTOM OF AWNING 1"X1" BOTTOM OF AWNING LOWER ATTACHMENT DETAIL N EVERY RETURN ARM REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR LOWER ATTACHMENT LOWER CORNER DETAIL W FRAME #1 & #2 FOR ATTACHMENT NEA 1"X1" TOP OF AWNING 1"X1" PURLIN FOR ROOFING EXISTING WALL STUCCO OVER BRICK (BY OTHERS) 114" X 1" TEK SCREW 3/8" THREADED ROD WITH HILTI HY70 EPDXY MIN EMB 4" 3/8" LOCK NUT 1" SINGLE HOLE Z-BRAKCET 12.05.2017 REVIEWED FOR CODE COMPLIANCE APPROVED CORNEJEC 0 7 2017 City of Tukwila BUILDING DIVISION EXISTING WALL STUCCO OVER BRICK (BY OTHERS) IVED TUKWILA DEC 06 2011 PERMIT CENTER UPPER ATTACHMENT DETAIL M EVERY 24" O.C. STANDING SEAM AWNING .X=± 1/4" .XX = ± 1/16" ANGLES =± 1° HARRIS PROPERTY MANAGEMENT ELEVATION VIEW CONTINUED RAINIER INDUSTRIES LTD *" N/A 394166.1-1 PAGE P4 FILE NAME: P:\DTS\DEVELOPMENT HARRIS PROPERTY MANAGEMENT 394166 - STANDING SEAM WEDGE AWNING\394166-1-1 -1 EA STANDING SEAM WEDGE AWNING\DRAWING1394166-1-1 - PACK AND GO\ 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part Direction LENGTH ANGLE1 ANGLE2 1 1 lin x lin x 0.110in Alum. Tube 1210-0011 35" 0.00 45.00 2 1 2in x lin x 0.125in Alum. Tube 1210-0013 226" 45.00 0.00 3 1 lin x lin x 0.110in Alum. Tube 1210-0011 681 /8" 30.02 29.95 4 1 lin x lin x 0.110in Alum. Tube 1210-0011 2" 45.00 30.02 5 1 1in x lin x 0.110in Alum. Tube 1210-0011 60" 45.00 45.00 6 9 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 7 9 lin x lin x 0.110in Alum. Tube 1210-0011 58" 0.00 0.00 8 6 lin x lin x 0.110in Alum. Tube 1210-0011 67 1/2" 0.00 29.93 9 11 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 16 15/16" 0.00 29.95 10 1 lin x lin x 0.110in Alum. Tube 1210-0011 168" 14.98 0.00 11 1 lin x lin x 0.110in Alum. Tube 1210-0011 89 1/8" 12 1 2in x lin x 0.125in Alum. Tube 1210-0013 59" 45.00 0.00 13 1 lin x lin x 0.110in Alum. Tube 1210-0011 68 1/8° 30.02 14.98 14 1 lin x lin x 0.110in Alum. Tube 1210-0011 226" 45.00 0.00 15 1 lin x lin x 0.110in Alum. Tube 1210-0011 2" 30.02 45.00 16 1 lin x lin x 0.110in Alum. Tube 1210-0011 59 5/8" 17 1 lin x lin x 0.110in Alum. Tube 1210-0011 24 7/16" 18 1 lin x lin x 0.110in Alum. Tube 1210-0011 3 11/16" 19 1 lin x lin x 0.110in Alum. Tube 1210-0011 451 /4" 20 1 lin x lin x 0.110in Alum. Tube 1210-0011 82" 21 1 lin x lin x 0.110in Alum. Tube 1210-0011 17 3/16" 0.00 22 1 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 198 13/16" 45.00 0.00 23 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 31 13/16" 0.00 45.00 24 1 lin x lin x 0.110in Alum. Tube 1210-0011 170 11/16" 45.00 0.00 25 1 lin x lin x 0.110in Alum. Tube 1210-0011 191 7/16" 45.00 0.00 26 1 lin x lin x 0.110in Alum. Tube 1210-0011 226 5/8" 45.00 0.00 27 1 lin x lin x 0.110in Alum. Tube 1210-0011 212 1/4" 45.00 0.00 REV A REVISIONS HISTORY DESCRIPTION PRELIMINARY DWGS BY TCS DATE APPR 11/28/2017 APR 12.05.2017 REVIEWED FOR DE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila UILDING DIVISION 4S144I ISOMETRIC VIEW OF 394166-1-1 - NORTH WALL FRAME QTY (1) .X=±1/4" .XX = ± 1/16" ANGLES = ± 1° ECEIVED CIOF TUKWILA DEC 06 2011 PERMIT CENTER STANDING SEAM AWNING HARRIS PROPERTY MANAGEMENT ISOMETRIC CUT LIST RAINIER INDUSTRIES LTD RANIER PAW. N/A �,- 394166-1-1 PAGE P5 FILE NAME: P:\DTS\DEVELOPMENT\ HARRIS PROPERTY MANAGEMENT\394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ 1 2 4 5 6 7 8 168" O r �N CO 00 TOP VIEW OF 394166-1-1 - NORTH WALL FRAME 168" 50 r ,0 CN N 1/ 66 is 60° 0 C0I,0 r,N C") 00 L1) FRONT VIEW OF 394166-1-1 - NORTH WALL FRAME LO CT 0 �o REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR 12.05.2017 REVIEWED FOR CODE COMPLIANCE N ° \\ APPROVED b(2) -S DEC 0 7 2017 6ity of Tukwila BU DING DIVISION 60" 3016" RIGHT VIEW OF 394166.1.1 - NORTH WALL FRAME RECEIVED CITY OF TUKWILA DEC 062017 PERMIT CENTER STANDING SEAM AWNING .X=±1/4" .XX = ± 1/16" ANGLES =± 1° HARRIS PROPERTY MANAGEMENT WEDGEpFRAME DETAIL RAINIER INDUSTRIES LTD RANIER PART If N/A 394166.1-1 PAGE P6 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT\394166 - STANDING SEAM WEDGE AWNING1394166-1-1 -1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part Direction LENGTH ANGLE1 ANGLE2 1 2 lin x lin x 0.110in Alum. Tube 1210-0011 35" 0.00 45.00 2 1 2in x lin x 0.125in Alum. Tube 1210-0013 238" 0.00 0.00 3 2 lin x lin x 0.110in Alum. Tube 1210-0011 681/8" 30.02 29.95 4 2 lin x lin x 0.110in Alum. Tube 1210-0011 2" 45.00 30.02 5 2 lin x lin x 0.110in Alum. Tube 1210-0011 60" 45.00 45.00 6 12 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 7 12 lin x lin x 0.110in Alum. Tube 1210-0011 58" 0.00 0.00 B 8 9 lin x lin x 0.110in Alum. Tube 1210-0011 671 /2" 0.00 29.93 9 14 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 16 15/16" 0.00 29.95 10 5 lin x lin x 0.110in Alum. Tube 1210-0011 240" 0.00 0.00 11 1 lin x lin x 0.110in Alum. Tube 1210-0011 238" 0.00 0.00 12 1 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 239 3/4" 0.00 0.00 C - REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR 12.05.2017 ISOMETRIC VIEW OF 394166-1-1 - WEST WALL FRAME QTY (2) RECEIVED CITY OF TUKWILA DEC 062011 PERMIT CENTER STANDING SEAM AWNING .X=±1/4" .XX =±1/16" ANGLES = ± 1° HARRIS PROPERTY MANAGEMENT ISOMETRIC CUT LIST(2) RA WER RAINIER INDUSTRIES LTD RANNEIR F N/A es, 394166-1-1 P7 FILE NAME: P:\DTS\DEVELOPMENTIHARRIS PROPERTY MANAGEMENT1394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ 1 7 8 O 240" TOP VIEW OF 394166-1-1 - WEST WALL FRAME O CO N ^IN MOO FRONT VIEW OF 394166-1-1 - WEST WALL FRAME col— ^100 LO N O N REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR RIGHT VIEW OF 394166-1-1 - WEST WALL FRAME 12.05.2017 REVIEWED R CODE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 06 2017 PERMIT CENTER STANDING SEAM AWNING .X=±1/4" .XX =±1/16" ANGLES = ± 1° HARRIS PROPERTY MANAGEMENT WEDGEpFRAME DETAIL(2) RAINIER INDUSTRIES LTD P PAC N/A 394166.1-1 P8 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT\394166 - STANDING SEAM WEDGE AWNING\394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ 8 12 16" PROFILE VIEW OF 394166.1.1 - NRM 1000 24 GAUGE REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWGS TCS 11/28/2017 APR ISOMETRIC VIEW OF 394166.1.1 - NRM 1000 24 GAUGE 69" 12.05.2017 REVIEWEV F=OR CODE COMPLIANCE APPROVED DEC 0 7 2017 City of Tukwila BUILDING DIVISION RIGHT VIEW OF 394166-1-1 NRM 1000 24 GAUGE RECEIVED CITY OF TUKWILA DEC 06 2011 PERMIT CENTER STANDING SEAM AWNING .X = ± 1/4" .)0(=± 1/16° ANGLES = ± 1° HARRIS PROPERTY MANAGEMENT ROOFING PANELS RAINIER INDUSTRIES LTD N/A 394166-1-1 PAGE P9 FILE NAME: P:\DTS\DEVELOPMENT\HARRIS PROPERTY MANAGEMENT\ 394166 - STANDING SEAM WEDGE AWNING \394166-1-1 - 1 EA STANDING SEAM WEDGE AWNING\DRAWING\394166-1-1 - PACK AND GO\ E1* NGINEERING STRUCTURAL ENGINEERS & CONSULTANTS F STRUCTURAL CALCULATIONS PROJECT NAME: Harris Property Management Awning PROJECT ADDRESS: 12404 42nd Ave S, Seattle, WA PROJECT NO: 17248 CLIENT: Luke Walker COMPANY: Rainer Industries 18375 Olympic Ave. S Tukwila, WA 98188 DATE: Dec 05, 2017 12/05/2017 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 7 2011 ' City of Tukwila BUILDING DIVISION HW Engineering License and Non Disclosure and Reproduction IMPORTANT NOTICE TO BUILDING AND SAFETY PERSONNEL - The enclosed calculations and hard copy prints ("Enclosed") are copyright protected by HW Engineering. It is understood that while the Enclosed may be required for verification of structural design and approval, it is not necessary for the manufacture or construction of the structure or its components. It is the express wish of HW Engineering that these proprietary calculations not be retumed or redistributed to anyone other than the copyrighted owner as referenced in the ownership paragraph below and that any unnecessary submitted copies be retumed or destroyed. Ownership: This document and the Enclosed are copyrighted by HW Engineering, 6270 McLeod Drive, Suite 140, Las Vegas, NV 89120. All rights reserved. This is not a sale or transference; all right, title and interest in the Document (in both electronic file and hard copy) belong to HW Engineering. CORRECTION LTR#�®-- REV DATE BY DESCRIPTION A A REGI A CITY OF A bv7 0302 IVED U KWILA DEC 06 2011 PERMIT CENTER 6270 McLeod Drive, Suite 140, Las Vegas, NV 89120 Phone: 702.202.0061 hongyu@hwengineeringUSA.com www.hwengineeringUSA.com HW Engingering Job #17248 1/22 12/05/2017 1.1 Basis for Design BUILDING CODE: 2015 International Building Code 1.2 GRAVITY DESIGN: ROOF LOADING DEAD LOAD (PSF) Frame self -weight LIVE LOAD (PSF) 20psf SNOW LOAD (PSF) 25psf (minimum required) 1.3 LATERAL DESIGN: WIND LOADING Basic Wind Speed (3s — Gust) 110 Risk Category II Exposure Category D SEISMIC LOADING Risk Category II Ss, S1 1.503, 0.564 Soil Site Class D Sds, Sdl 1.002, 0.564 Seismic Design Category D ap,RP 1.0, 2.5 2.1 ALUMINUM DESIGN: Extruded 6061-T6 with minimum yield stress equal to 35 ksi. ER4043 electrodes/rods shall be used for all aluminum to aluminum welds. 3.1 INSPECTION, SPECIAL INSPECTION, AND STRUCTURAL OBSERVATION: AS REQUIRED BY THE GOVERNING MUNICIPALITY. HW Engingering Job #17248 2/22 SAP2000 12/05/2017 SAP2000 - File:Harris Property Management Awning - 3-D View HW Engingering Job #17248 3/22 12/05/2017 Design Summary The analysis and design of the awning system included herein were performed with the use of a 3D frame analysis and computer design program — SAP2000. It is a structural analysis program developed by Computers and Structures, Inc. Detailed information about the software can be found at the Computers and Structures, Inc. website. 1. FRAME GEOMETRY The geometry for the awning model was based on a centerline interpretation of a typical awning. The centerline computer model was developed from client drawings and compiled to create a simplified model for analysis. 2. EXTERNALLY APPLIED LOADS Loads for this structure have been conservatively determined by referencing the current International Building Code 2015(IBC 2015) and ASCE 7-10 Standards and Provisions. Design dead load was based on the awning self -weight plus an additional dead load of 2.0 psf to account for the weight of the cover panel. Live load was taken to be 20 psf per code requirement. Wind load was calculated based on "Components and Cladding" for enclosed buildings (see design load calculation). 3. ANALYSIS FOR MEMBER FORCES The awning frame will be constructed of lxlx.1, 2xlx.125 and 3/4x3/4x.11 aluminum tubes. Refer to structural drawings for detailed member sizes and locations. From computer structural analysis, all framing members were designed based on the above mentioned design loads. Aluminum Design ASD design specifications were used to check the structural capacities of these members based on an applicable minimum yield stress. The demand/capacity ratio of each framing member was calculated and found to be less than 1.0 for all members. All connections were checked by hand calculation based on worst case structural analysis output reactions. HW Engingering Job #17248 4/22 12/05/2017 Design Loads Design Dead Loads Framing and roof panel self weight. Framing weight will be included in to computer model automatically. Add 2.0 psf for roof panel weight. DL = 2.0psf LL = 20psf Design Live Loads Design Wind Loads Wind parameters: 110 mph wind speed, exposure D. Wind loads are based on IBC2015/ASCE 7-10 components and cladding for enclosed buildings -roof zone 2 effective wind area 20sgf (Figures 30.5-1). Mean roof height is Tess than 15ft. V = 110 mph k 1 = 1.0 for slope over 27 degree 19.4 Pnet30 = psf -24.3 Figure 26.5-1A basic wind speed for occupancy category II Section 26.8.2 Figure 30.5-1 X = 1.47 Figure 30.5-1, exposure D 28.52 1 design wind pressure p = X kzt Pnet30 P = J psf -35.72 Design wind force shall be not less than 16psf according as section 30.2.2 of ASCE 7-10 Pn,;n = 16 psf Design Snow Load Ground snow Toad pg = 20 psf I = 1.0 Ce = 0.9 pf = 0.7 Ce Ct I Pg snow load (sloped roof snow load) Design Seismic Loads Design perASCE7-10. Ip= 1.0 SDS= 1.002 ap= 1.0 Rp=2.5 L = 20 ft Framing and roof panel total weight will be around 4 psf Ip / Seismic force Fpl = 0.4 ap SDS DL 1 Rp Fp2 = 1.6 SDS Ip DL Fp3 = 0.3 SDS Ip DL Fp = Fp3) Total max. seismic load Seismic = F B L Minimum wind load design Windmin = 0.6 (16 psf L h) Ct = 1.2 pf = 15.12 psf Ps = Cs Pf Snow = max(ps,25 psf) Cs = 1.0 Ps = 15.12 psf Snow = 25 psf larger than live Toad B = 5 ft DL = 4 psf + 2 h Fp' = 1.92 psf Fp2 = 6.413 psf maximum force Fp3 = 1.2 psf minimum force Fp = 1.35 psf Seismic = 135 lbf Windmin = 576 lbf Check = if(Windmin > Seismic, "Wind controls design" , "Seismic controls design" ) Check = "Wind controls design" HW Engingering Job #17248 5/22 UsGs Design Maps Summary Report User -Specified Input Report Title Harris Property Management Awning Thu November 30, 2017 04:33:44 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 47.49213°N, 122.27975°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III fNG Oft NA VAL„,1 ; ---°],J— -=.---A*-- � ty BASE BOE1NG( Al‘1111 . ''1 \ ,FL .Ir)JG RENTON Issaquah .- - 11 �t��\ WON! ,i .IRP ORT BUrieni 1fi `i • penton Vashor; ' SEAiT'€f' 1 TACOMA INTL f� AIRPORT Maple Valley Des Moines. USGS-Provided Output SS = 1.503 g Si = 0.564 g SMS = 1.503 g SM 1 = 0.846 g SDS= 1.002g SD1 = 0.564 g 12/05/2017 For information on how the SS and 51 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP” building code reference document. Map Response Spectrurn Perm T (sec) 1.10 ass am 0.77 nm Design Response Spectrum 0.11 am om n20 CIAO For PGAM, TL, CRS, and CR1 values, please view the detailed report. HW Engingering Job #17248 001 1120 tao 1_0 1AO 111] 1.67 200 Period.T (sec) 6/22 SAP2000 12/05/2017 SAP2000 - File:Harris Property Management Awning - 3-D View HW Engingering Job #17248 7/22 SAP2000 12/05/2017 SAP2000 - File:Harris Property Management Awning - 3-D View HW Engingering Job #17248 8/22 SAP2000 12/05/2017 SAP2000 - File:Harris Property Management Awning - 3-D View 11W Engingering Job #17248 9/22 SAP2000 12/05/2017 SAP2000 - File:Harris Property Management Awning -Aluminum P -M Interaction Ratios (AA -ASD) HW Engingering Job #17248 10/22 12/05/2017 Table: Material Properties 03c - Aluminum Data Material AlumType Alloy Fcy Fty Ftu Fsu= SSHysType Kip/in2 Kip/iin2 Kip/in2 Kip/in2. 6061T6 Wrought 6061-T6 35.000 35.000 38.000 24.000= Kinematic Table: Frame Section Properties 01 - General SectionName Material Shape t3 t2 tf tw 1 in in in in 1x1x.11 6061T6 Box/Tube 1.0000 1.0000 0.1100 0.1100 2x1 x.125 6061T6 Box/Tube 2.0000 1.0000 0.1250 0.1250 3/4x3/4x.11 6061T6 Box/Tube 0.7500 0.7500 0.1100 0.1100 SectionName 1x1x.11 2x1 x.125 3/4x3/4x.11 Area TorsConst 133 122 AS2 AS3 S33 1 in2 in4 in4 in4 in2 in2 in3 0.39 7.755E-02 5.249E-02 5.249E-02 0.22 0.22 0.10 0.69 0.24 0.33 0.11 0.50 0.25 0.33 0.28 2.884E-02 1.979E-02 1.979E-02 0.17 0.17 5.278E-02 SectionName S22 Z33 Z22 R33 R22 ConcCol ConcBeam in3 in3 in3 1n in 1x1x.11 2x1x.125 3/4x3/4x.11 0.10 0.13 0.13 0.21 0.43 0.25 5.278E-02 6.825E-02 6.825E-02 0.3661 0.6946 0.2651 0.3661 0.3911 0.2651 No No No No No No SectionName Color TotalWt TotalMass FromFile AMod A2Mod A3Mod Kip Kip-s2/in 1x1x.11 2x1 x.125 3/4x3/4x.11 8421631 Blue 8453888 0.103 2.668E-04 0.019 5.012E-05 6.251 E-03 1.620E-05 No No No 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 SectionName 1x1x.11 2x1 x.125 3/4x3/4x.11 JMod I2Mod I3Mod MMod WMod GUID 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 1.000000 Table: Load Pattern Definitions LoadPat DesignType SeIfWtMult AutoLoad GUID Notes Dead DEAD 1.000000 SN SNOW 0.000000 HW Engingering Job # 17248 11/22 12/05/2017 LoadPat DesignType SelUWtMult AutoLoad GUID Notes W16 WIND 0.000000 None WA WIND 0.000000 None WB WIND 0.000000 None Table: Load Case Definitions Case Type InitialCond ModalCase BaseCase DesTypeOpt DesignType DesActOpt DL LinStatic Zero Prog Det DEAD Prog Det SN LinStatic Zero Prog Det SNOW Prog Det W16 LinStatic Zero Prog Det WIND Prog Det WA LinStatic Zero Prog Det WIND Prog Det WB LinStatic Zero Prog Det WIND Prog Det Case DesignAct AutoType RunCase CaseStatus GUID Notes I DL Non -Composite None Yes Finished SN Short -Terni Composite None Yes Finished W16 Short -Tenn Composite None Yes Finished WA Short -Term Composite None Yes Finished WB Short -Terni Composite None Yes Finished Table: Combination Definitions ComboName ComboType AutoDesign CaseType CaseName ScaleFactor SteelDesign DL+SN Linear Add No Linear Static DL 1.000000 Strength DL+SN Linear Static SN 1.000000 DL+0.6WA Linear Add No Linear Static DL 1.000000 Strength DL+0.6WA Linear Static WA 0.600000 DL+0.6WB Linear Add No Linear Static , DL 1.000000 Strength DL+0.6WB Linear Static WB 0.600000 DL+0.6W16 Linear Add No Linear Static DL 1.000000 Strength DL+0.6W16 Linear Static W16 0.600000 0.6DL+0.6WA Linear Add No Linear Static DL 0.600000 Strength 0.6DL+0.6WA Linear Static WA 0.600000 0.6DL+0.6WB Linear Add No Linear Static DL 0.600000 Strength 0.6DL+0.6WB Linear Static WB 0.600000 DL+0.75(SN+0.6WA) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6WA) Linear Static SN 0.750000 DL+0.75(SN+0.6WA) Linear Static WA 0.450000 DL+0.75(SN+0.6WB) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6WB) Linear Static SN 0.750000 DL+0.75(SN+0.6WB) Linear Static WB 0.450000 DL+0.75(SN+0.6W16) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6W16) Linear Static W16 0.450000 HW Engingering Job 1117248 12/22 12/05/2017 1 ComboName ComboType AutoDesign CaseType CaseName ScaleFactor SteelDesign DL+0.75(SN+0.6W16) Linear Static SN 0.750000 Table: Frame Loads - Distributed I Frame LoadPat CoordSys Type, Dir DistType RelDistA RelDistB FOverLA Lb/ft 25 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.75 25 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 21.88 25 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 8.33 25 WA Local Force 2 RelDist 0.0000 1.0000 -28.52 25 WB Local Force 2 RelDist 0.0000 1.0000 35.72 24 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 24 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 24 WB Local Force 2 RelDist 0.0000 1.0000 71.44 24 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 16 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 16 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 16 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 16 WB Local Force 2 RelDist 0.0000 1.0000 66.98 8 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 8 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 8 WB Local Force 2 RelDist 0.0000 1.0000 31.26 8 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 17 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 17 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 17 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 17 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 17 WB Local Force 2 RelDist 0.0000 1.0000 71.44 18 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 18 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 18 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 18 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 18 WB Local Force 2 RelDist 0.0000 1.0000 71.44 19 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 19 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 19 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 19 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 19 WB Local Force 2 RelDist 0.0000 1.0000 71.44 20 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 20 SN • GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 20 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 20 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 20 WB Local Force 2 RelDist 0.0000 1.0000 71.44 21 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 21 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 21 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 21 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 21 WB Local Force 2 RelDist 0.0000 1.0000 71.44 FOverLB Lb/ft 1.75 21.88 8.33 -28.52 35.72 43.75 3.50 71.44 -57.04 3.25 40.63 -53.48 66.98 1.50 18.75 31.26 -24.95 3.50 43.75 16.67 -57.04 71.44 3.50 43.75 16.67 -57.04 71.44 3.50 43.75 16.67 -57.04 71.44 3.50 43.75 16.67 -57.04 71.44 3.50 43.75 16.67 -57.04 71.44 HW Engingering Job #17248 13/22 12/05/2017 f Frame LoadPat CoordSys Type Dir DistType RelDistA RelDistB FOverLA FOverLB Lb/ft. Lb/ft 22 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 3.50 22 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75. 43.75 22 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 22 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 -57.04 22 WB Local Force 2 RelDist 0.0000 1.0000 71.44 71.44 23 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.50 3.50 23 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 43.75 ' 43.75 23 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 23 WA Local Force 2 RelDist 0.0000 1.0000 -57.04 -57.04 23 WB Local Force 2 RelDist 0.0000 1.0000 71.44 71.44 9 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 9 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 9 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 ' 16.67 9 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 9 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 10 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 10 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 10 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 10 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 10 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 11 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 11 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 11 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 11 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 11 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 12 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25. 3.25 12 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 12 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 12 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 12 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 13 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 13 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 13 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 • 16.67 13 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 . -53.48 13 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 14 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 14 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 14 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 14 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 14 WB Local Force 2 RelDist 0.0000 1.0000 66.98 ; 66.98 15 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 3.25 3.25 15 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 40.63 40.63 15 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 16.67 16.67 15 WA Local Force 2 RelDist 0.0000 1.0000 -53.48 -53.48 15 WB Local Force 2 RelDist 0.0000 1.0000 66.98 66.98 1 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 1 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 1 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 1 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 ' -24.95 HW Engingering Job #17248 14/22 12/05/2017 I Frame LoadPat CoordSys Type Dir DistType RelDistA ReIDistB FOverLA FOverLB Lb/ft Lb/ft 1 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 2 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 2 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 2 W16 GLOBAL Force - Y Proj RelDist 0.0000 1.0000 7.33 7.33 2 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 2 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 3 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 3 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 3 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 3 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 3 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 4 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 4 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 4 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 4 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 4 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 5 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 5 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75,. 18.75 5 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 5 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 5 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 6 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 ' 1.50 6 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 6 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 6 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 6 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 7 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 1.50 1.50 7 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 18.75 18.75 7 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 7.33 7.33 7 WA Local Force 2 RelDist 0.0000 1.0000 -24.95 -24.95 7 WB Local Force 2 RelDist 0.0000 1.0000 31.26 31.26 Table: Preferences - Aluminum Design - AA -ASD THDesign FrameType SRatioLimit Maxiter LatFact UseLatFact Bridge Envelopes Moment Frame 1.000000 1 1.230000 No No Table: Aluminum Design 1 - Summary Data - AA -ASD Frame DesignSect DeslgnType Ratio RatioType Combo 26 2x1x.125 Beam 0.166172 PMM 0.6DL+0.6WB 27 1x1x.11 Beam 0.449984 PMM DL+0.75(SN+0.6WA) 62 1x1x.11 Column 0.359357 PMM DL+0.75(SN+0.6WA) 46 1x1x.11 Column 0.498409 PMM DL+0.75(SN+0.6WA) 35 2x1x.125 Beam 0.239488 PMM DL+0.75(SN+0.6WA) 33 1x1x.11 Beam 0.847277 PMM DL+0.75(SN+0.6WA) HW Engingering Job #17248 15/22 12/05/2017 Frame DesignSect DesignType Ratio RatioType Combo I 68 1x1x.11 Column 0.807335 PMM 0.6DL+0.6WB 52 1x1x.11 Column 0.704278 PMM DL+0.75(SN+0.6WA) 25 1x1x.11 Beam 0.277542 PMM DL+0.75(SN+0.6WA) 29 1x1x.11 Beam 0.759174 PMM DL+0.75(SN+0.6WA) 64 1x1x.11 Column 0.494782 PMM DL+0.75(SN+0.6WA) 48 1x1x.11 Column 0.656485 PMM DL+0.75(SN+0.6WA) 31 1x1x.11 Beam 0.762557 PMM DL+0.75(SN+0.6WA) 66 1x1x.11 Column 0.502194 PMM DL+0.75(SN+0.6WA) 50 1x1x.11 Column 0.655425 PMM DL+0.75(SN+0.6WA) 44 1x1x.11 Beam 0.521938 PMM DL+0.75(SN+0.6WA) 45 1x1x.11 Column 0.701296 PMM DL+0.75(SN+0.6WA) 54 1x1x.11 Brace 0.408856 PMM DL+0.75(SN+0.6WA) 69 1x1x.11 Brace 0.699543 PMM DL+075(SN+0.6WA) 24 1x1x.11 Beam 0.315535 PMM DL+0.75(SN+0.6WA) 16 1x1x.11 Beam 0.544951 PMM DL+0.75(SN+0.6WA) 8 1x1x.11 Beam 0.483902 PMM DL+0.75(SN+0.6WA) 61 1x1x.11 Brace 0.641463 PMM DL+0.75(SN+0.6WA) 34 1x1x.11 Beam 0.930639 PMM DL+0.75(SN+0.6WA) 53 1x1x.11 Column 0.621463 PMM DL+0.75(SN+0.6WA) 17 1x1x.11 Beam 0.149835 PMM DL+0.75(SN+0.6WA) 18 1x1x.11 Beam 0.197932 PMM DL+0:75(SN+0.6WA) 19 1x1x.11 Beam 0.212384 PMM DL+0.75(SN+0.6WA) 20 1x1x.11 Beam 0.217509 PMM DL+0.75(SN+0.6WA) 21 1x1x.11 Beam 0.221974 PMM DL+0.75(SN+0.6WA) 22 1x1x.11 Beam 0.215389 PMM DL+0.75(SN+0.6WA) 23 1x1x.11 Beam 0.248395 PMM DL+0.75(SN+0.6WA) 9 1x1x.11 Beam 0.145058 PMM DL+0.75(SN+0.6WA) 10 1x1x.11 Beam 0.190880 PMM DL+0.75(SN+0.6WA) 11 1x1x.11 Beam 0.216078 PMM DL+0.75(SN+0.6WA) 12 1x1x.11 Beam 0.225607 PMM DL+0.75(SN+0.6WA) 13 1x1x.11 Beam 0.229468 PMM DL+0.75(SN+0.6WA) 14 1x1x.11 Beam 0.291593 PMM DL+0.75(SN+0.6WA) 15 1x1x.11 Beam 0.521896 PMM DL+0.75(SN+0.6WA) 28 1x1x.11 Beam 0.713423 PMM DL+0.75(SN+0.6WA) 47 1x1x.11 Column 0.670994 PMM DL+0.75(SN+0.6WA) 30 1x1x.11 Beam 0.763259 PMM DL+0.75(SN+0.6WA) 49 1x1x.11 Column 0.656074 PMM DL+0.75(SN+0.6WA) 32 1x1x.11 Beam 0.741095 PMM DL+0.75(SN+0.6WA) 63 1x1x.11 Column 0.452711 PMM DL+0.75(SN+0.6WA) 65 1x1x.11 Column 0.496703 PMM DL+0.75(SN+0.6WA) 67 1x1x.11 Column 0.511692 PMM DL+0.75(SN+0.6WA) 1 1x1x.11 Beam 0.078935 PMM DL+0.75(SN+0.6WA) 2 1x1x.11 Beam 0.106214 PMM DL+0.75(SN+0.6WA) 3 1x1x.11 Beam 0.108889 PMM DL+0.75(SN+0.6WA) 4 1x1x.11 Beam 0.110089 PMM DL+0.75(SN+0.6WA) 5 1x1x.11 Beam 0.112323 PMM DL+0.75(SN+0.6WA) 6 1x1x.11 Beam 0.164939 PMM DL+0.75(SN+0.6WA) 7 1x1x.11 Beam 0.534823 PMM DL+0.75(SN+0.6WA) 60 1x1x.11 Brace 0.604592 PMM DL+0.75(SN+0.6WA) HW Engingering Job #17248 16/22 12/05/2017 Frame DesignSect DesignType Ratio RatioType Combo I 55 1xlx.11 Brace 0.630346 PMM DL+0.75(SN+0.6WA) 56 1xlx.11 Brace 0.651557 PMM DL+0.75(SN+0.6WA) 57 1xlx.11 Brace 0.651676 PMM DL+0.75(SN+0.6WA) 58 1xlx.11 Brace 0.651555 PMM DL+0.75(SN+0.6WA) 59 1xlx.11 Brace 0.647076 PMM DL+0.75(SN+0.6WA) 51 1xlx.11 Column 0.646201 PMM DL+0.75(SN+0.6WA) 36 3/4x3/4x.11 Beam 0.213759 PMM DL+0.75(SN+0.6WA) 37 3/4x3/4x.11 Beam 0.083900 PMM DL+0.75(SN+0.6WA) 38 3/4x3/4x.11 Beam 0.074735 PMM 0.6DL+0.6WB 39 3/4x3/4x.11 Beam 0.081672 PMM 0.6DL+0.6WB 40 3/4x3/4x.11 Beam 0.087879 PMM 0.6DL+0.6WB 41 3/4x3/4x.11 Beam 0.097482 PMM 0.6DL+0.6WB 42 3/4x3/4x.11 Beam 0.115556 PMM 0.6DL+0.6WB 43 3/4x3/4x.11 Beam 0.484946 PMM DL+0:75(SN+0.6WA) Table: Joint Reactions Joint OutputCase CaseType F1 F2 F31 Kip Kip Kip 1 DL+SN Combination 0.003 -0.140 0.000 1 DL+0.6WA Combination 0.003 -0.129 0.000 1 DL+0.6WB Combination -0.003 0.121 0.000 1 DL+0.6W16 Combination -0.001 -0.030 0.000 1 0.6DL+0.6WA Combination 0.003 -0.122 0.000 1 0.6DL+0.6WB Combination -0.003 0.128 0.000 1 DL+0.75(SN+0.6WA) Combination 0.004 -0.193 0.000 1 DL+0.75(SN+0.6WB) Combination 0.000 -0.005 0.000 1 DL+0.75(SN+0.6W16) Combination 0.002 -0.119 0.000 2 DL+SN Combination 0.000 -0.275 0.000 2 DL+0.6WA Combination 0.000 -0.257 0.000 2 DL+0.6WB Combination 0.000 0.250 0.000 2 DL+0.6W16 Combination -0.002 -0.068 0.000 2 0.6DL+0.6WA Combination 0.000 -0.244 0.000 2 0.6DL+0.6WB Combination 0.000 0.263 0.000 2 DL+0.75(SN+0.6WA) Combination 0.000 -0.383 0.000 2 DL+0.75(SN+0.6WB) Combination 0.000 -0.003 0.000 2 DL+0.75(SN+0.6W16) Combination -0.001 -0.242 0.000 3 DL+SN Combination 0.000 -0.279 0.000 3 DL+0.6WA Combination 0.000 -0.259 0.000 3 DL+0.6WB Combination 0.000 0.252 0.000 3 DL+0.6W16 Combination -0.002 -0.067 0.000 3 0.6DL+0.6WA Combination 0.000 -0.246 0.000 3 0.6DL+0.6WB Combination 0.000 0.265 0.000 3 DL+0.75(SN+0.6WA) Combination 0.000 -0.388 0.000 3 DL+0.75(SN+0.6WB) Combination 0.000 -0.005 0.000 3 DL+0.75(SN+0.6W16) Combination -0.001 -0.243 0.000 4 DL+SN Combination 0.000 -0.276 0.000 4 DL+0.6WA Combination 0.000 -0.257 0.000 HW Engingering Job #17248 17/22 Joint OutputCase CaseType F1 F2 F3 Kip Kip Kip 4 DL+0.6WB Combination 0.000 0.250 0.000 4 DL+0.6W16 Combination -0.002 -0.066 0.000 4 0.6DL+0.6WA Combination 0.000 -0.244 0.000 4 0.6DL+0.6WB Combination 0.000 0.262 0.000 4 DL+0.75(SN+0.6WA) Combination 0.000 -0.384 0.000 4 DL+0.75(SN+0.6WB) Combination 0.000 -0.004 0.000 4 DL+0.75(SN+0.6W16) Combination -0.002 -0.241 0.000 5 DL+SN Combination 0.000 -0.275 0.000 5 DL+0.6WA Combination 0.000 -0.256 0.000 5 DL+0.6WB Combination 0.000 0.249 0.000 5 DL+0.6W16 Combination -0.002 -0.067 0.000 5 0.6DL+0.6WA Combination 0.000 -0.243 0.000 5 0.6DL+0.6WB Combination 0.000 0.262 0.000 5 DL+0.75(SN+0.6WA) Combination 0.000 -0.382 0.000 5 DL+0.75(SN+0.6WB) Combination 0.000 -0.004 0.000 5 DL+0.75(SN+0.6W16) Combination -0.001 -0.240 0.000 6 DL+SN Combination -0.003 -0.237 0.000 6 DL+0.6WA Combination -0.003 -0.221 0.000 6 DL+0.6WB Combination 0.002 0.217 0.000 6 DL+0.6W16 Combination -0.003 -0.055 0.000 6 0.6DL+0.6WA Combination -0.002 -0.211 0.000 6 0.6DL+0.6WB Combination 0.003 0.227 0.000 6 DL+0.75(SN+0.6WA) Combination -0.004 -0.330 0.000 6 DL+0.75(SN+0.6WB) Combination 0.000 -0.002 0.000 6 DL+0.75(SN+0.6W16) Combination -0.004 -0.205 0.000 7 DL+SN Combination 0.609 -0.778 0.000 7 DL+0.6WA Combination 0.524 -0.679 0.000 7 DL+0.6WB Combination -0.490 0.644 0.000 7 DL+0.6W16 Combination 0.098 -0.168 0.000 7 0.6DL+0.6WA Combination 0.494 -0.642 0.000 7 0.6DL+0.6WB Combination -0.520 0.681 0.000 7 DL+0.75(SN+0.6WA) Combination 0.813 -1.047 0.000 7 DL+0.75(SN+0.6WB) Combination 0.052 -0.055 0.000 7 DL+0.75(SN+0.6W16) Combination 0.493 -0.664 0.000 8 DL+SN Combination 0.001 0.140 0.173 8 DL+0.6WA Combination 0.004 0.073 0.126 8 DL+0.6WB Combination -0.004 -0.050 -0.106 8 DL+0.6W16 Combination 0.000 0.007 0.026 8 0.6DL+0.6WA Combination 0.004 0.065 0.116 8 0.6DL+0.6WB Combination -0.005 -0.058 -0.115 8 DL+0.75(SN+0.6WA) Combination 0.003 0.150 0.212 8 DL+0.75(SN+0.6WB) Combination -0.003 0.058 0.039 8 DL+0.75(SN+0.6W16) Combination 0.001 0.101 0.138 9 DL+SN Combination 0.008 0.274 0.329 9 DL+0.6WA Combination 0.007 0.135 0.233 9 DL+0.6WB Combination -0.007 -0.097 -0.206 9 DL+0.6W16 Combination -0.002 -0.004 0.037 9 0.6DL+0.6WA Combination 0.007 0.122 0.218 9 0.6DL+0.6WB Combination -0.007 -0.110 -0.221 HW Engingering Job #17248 12/05/2017 18/22 12/05/2017 Joint OutputCase CaseType FI F2 F3 Kip Kip Kip 9 DL+0.75(SN+0.6WA) Combination 0.011 0.291 0.402 9 DL+0.75(SN+0.6WB) Combination 0.001 0.117 0.073 9 DL+0.75(SN+0.6W16) Combination 0.005 0.187 0.255 10 DL+SN Combination 0.008 0.279 0.332 10 DL+0.6WA Combination 0.007 0.140 0.237 10 DL+0.6WB Combination -0.006 -0.104 -0.210 10 DL+0.6W16 Combination -0.001 -0.002 0.039 10 0.6DL+0.6WA Combination 0.006 0.127 0.221 10 0.6DL+0.6WB Combination -0.007 -0.116 -0.225 10 DL+0.75(SN+0.6WA) Combination 0.010 0.298 0.407 10 DL+0.75(SN+0.6WB) Combination 0.000 0.115 0.072 10 DL+0.75(SN+0.6W16) Combination 0.004 0.192 0.259 11 DL+SN Combination 0.008 0.277 0.330 11 DL+0.6WA Combination 0.007 0.138 0.236 11 DL+0.6WB Combination -0.007 -0.102 -0.209 11 DL+0.6W16 Combination -0.001 -0.002 0.038 11 0.6DL+0.6WA Combination 0.006 0.126 0.220 11 0.6DL+0.6WB Combination -0.007 -0.114 -0.224 11 DL+0.75(SN+0.6WA) Combination 0.010 0.295 0.405 11 DL+0.75(SN+0.6WB) Combination 0.000 0.115 0.072 11 DL+0.75(SN+0.6W16) Combination 0.004 0.190 0.257 12 DL+SN Combination 0.007 0.273 0.334 12 DL+0.6WA Combination 0.007 0.136 0.238 12 DL+0.6WB Combination -0.006 -0.100 -0.211 12 DL+0.6W16 Combination -0.001 -0.002 0.039 12 0.6DL+0.6WA Combination 0.006 0.124 0.223 12 0.6DL+0.6WB Combination -0.007 -0.112 -0.227 12 DL+0.75(SN+0.6WA) Combination 0.010 0.291 0.410 12 DL+0.75(SN+0.6WB) Combination 0.000 0.114 0.072 12 DL+0.75(SN+0.6W16) Combination 0.004 0.187 0.260 13 DL+SN Combination 0.011 0.249 0.284 13 DL+0.6WA Combination 0.009 0.115 0.196 13 DL+0.6WB Combination -0.009 -0.080 -0.172 13 DL+0.6W16 Combination -0.001 -0.007 0.031 13 0.6DL+0.6WA Combination 0.009 0.104 0.183 13 0.6DL+0.6WB Combination -0.010 -0.091 -0.185 13 DL+0.75(SN+0.6WA) Combination 0.014 0.259 0.344 13 DL+0.75(SN+0.6WB) Combination 0.000 0.113 0.068 13 DL+0.75(SN+0.6W16) Combination 0.006 0.168 0.220 14 DL+SN Combination -0.653 0.769 0.899 14 DL+0.6WA Combination -0.441 0.485 0.649 14 DL+0.6WB Combination 0.376 -0.404 -0.569 14 DL+0.6W16 Combination -0.079 0.047 0.107 14 0.6DL+0.6WA Combination -0.409 0.449 0.605 14 0.6DL+0.6WB Combination 0.407 -0.440 -0.612 14 DL+0.75(SN+0.6WA) Combination -0.781 0.895 1.107 14 DL+0.75(SN+0.6WB) Combination -0.169 0.228 0.194 14 DL+0.75(SN+0.6W16) Combination -0.509 0.566 0.701 1 -IW Engingering Job #17248 19/22 Connection Check Awning top to wall attachment check (M/P4) maximum reaction from analysis VREc := 0.41 kip TREc := 0.3 kip using worst case reaction attachment horizontal spacing in model d := 28 in attachment horizontal trib. length D := 18 in attachment vertical spacing in model s := 35 in attachment vertical spacing S := 32 in Vmax VREc Tmax TREc d S Vmax = 264 lbf Tmax = 211 lbf Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va:= min(10631bf 35,990 lbf I Ta:= 3351bf 35 45 J 45 Screw demand/capacity ratio n := 1 Vmax Ratio := n Va Ratio = 0.32 check := if(Ratio <_ 1.0, "sufficient" ,"NG") Va ="827 lbf 12/05/2017 Ta = 261 lbf ESR -1976 check = "sufficient" Use 3/8" dia. threaded rod with Hilti HIT-HY 70 epoxy for z clip to existing wall n := — 5 3 Va:= 645 lbf Ta:= 390 lbf n n ratio := Vmax + Tmax ratio = 0.584 Va Num Ta Num check := if (ratio < 1.0, "sufficient" ,"NG") Awning bottom to wall attachment check (N/P4) maximum reaction from analysis VREc := 0.1 kip TREc := 0.27 kip using worst case reaction attachment horizontal spacing in model d := 28 in attachment horizontal trib. length D:= 28 in attachment vertical spacing in model s := 35 in attachment vertical spacing S := 33 in Vmax VREc Tmax TREc d S Vmax = 100 lbf Tmax = 286 Ibf ESR -2682 Num := 1 check = "sufficient" Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va := min 10631bf 35 ,990 lbf Ta := 3351bf 35 Va = 827 lbf 45 ) 45 Screw demand/capacity ratio n := 1 Ta = 261 lbf ESR -1976 HW Engingering Job #17248 20/22 12/05/2017 Ratio := Vmax n Va Ratio = 0.121 check := if(Ratio 1.0,"sufficient" ,"NG") check = "sufficient" Use 3/8" dia. threaded rod with Hilti HIT-HY 70 epoxy for z clip to existing wall Va := 645 lbf Ta := 390 lbf n := 3 n / )11 ratio := Vmax + Tmax ratio = 0.642 Va Num Ta Num check := if(ratio < 1.0,"sufficient" ,"NG") Awning top to wall attachment check (R/P4) maximum reaction from analysis VREc := 1.35 kip TREc := 0.9 kip attachment horizontal spacing in model attachment horizontal trib. length attachment vertical spacing in model attachment vertical spacing ESR -2682 Num := 1 check = "sufficient" using worst case reaction d := 28 in D := 28 in s := 35 in S := 32 in Vmax := VREc a Tmax := TREcd S Vmax = 1350 lbf Tmax = 984 lbf Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va := min�10631bf 35 ,990 Ibf I Ta := 3351bf 35 Va = 827 lbf Ta = 261 lbf ESR -1976 45 j 45 Screw demand/capacity ratio Vmax Ratio :— n Va Ratio = 0.82 n := 2 using one side screw for a conservative deisgn check := if(Ratio <_ 1.0,"sufficient" ,"NG") check = "sufficient" Use 3/8" dia. threaded rod with Hilti HIT HY 70 epoxy for z clip to existing wall Va := 645 lbf Ta := 390 lbf n := 5 3 ratio :— ESR -2682 Num := 4 2 each side, total 4 Vmax J n Tmax )n ratio = 0.804 anchors at comer + Va Num Ta Num check := if(ratio < 1.0, "sufficient" ,"NG") Awning bottom to wall attachment check (W/P4) maximum reaction from analysis VREc := 0.81 kip TREc := 0.7 kip using worst case reaction attachment horizontal spacing in model d := 28 in check = "sufficient" HW Engingering Job #17248 21/22 attachment horizontal trib. length D := 28 in attachment vertical spacing in model s := 35 in attachment vertical spacing S := 33 in 12 V. VREc Tmax TREc d S Vmax = 810 lbf Tmax = 742 lbf Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va:= min(10631bf 35,990 lbf I Ta:= 3351bf 35 45 J 45 Screw demand/capacity ratio Ratio := Vmax n Va Va = 827 lbf 12/05/2017 Ta = 261 lbf ESR -1976 n := 2 using one side screw for a conservative deisgn Ratio = 0.49 check := if(Ratio <_ 1.0, "sufficient" ,"NG") check = "sufficient" Use 3/8" dia. threaded rod with Hilti HIT-HY 70 epoxy for z clip to existing wall n := — 5 3 V, := 645 lbf Ta:= 390 lbf ( n ratio := V. + Tmax Va Num ( Ta Num) ratio = 0.435 check := if(ratio < 1.0, "sufficient" , "NG" ) Roof panel to frame attachment detail (J/P3, P9) Toads to panel frame spacing max uplift force DL :_ —2 psf b := 24 in ESR -2682 Num := 4 2 each side, total 4 anchors at comer check = "sufficient" W„ p := 36 psf panel width B := 12 in Tmax := (0.6 DL + 0.6W„p) b B Tmax = 41 lbf 1/4" screw for panel to frame 35 ksi Ta := 335 Ibf Ta = 261 lbf 45 ksi check := if (Tmax < Ta, "Connection is Ok" , "NG") check = "Connection is Ok" Frame to frame connections all aluminum tube —use minimum 1/8" ER4043 all around fillet weld, sufficient! HW Engingering Job #17248 22/22 City of Tukwila Department of Community Development November 07, 2017 LUKE WALKER 18375 OLYMPIC AVE S TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D 17-0302 HARR'Y OF ALLENTOWN - 12404 42 AVE S Dear LUKE WALKER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of"specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Due to the size of the awning and uncertainty of the brick to which the awning is proposed to be attached too, an engineer's analysis shall be required to verify the conditions. Engineer shall provide recommendations or provide details as necessary with engineer's calculations. The awning shall be designed to withstand seismic (D1), wind (110 mph) and snow loads (25 lb.). 2. Engineer shall show required welding details of trusses and specify on the plan special inspections for bolting and welding. 3. Provide specifications with attachment details of the standing seam roofing. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D17-0302 R -rAk 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PER IT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0302 DATE: 12/06/17 PROJECT NAME: HARRY'S OF ALLENTOWN SITE ADDRESS: 12404 42 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural ❑ Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/07/17 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 01/04/18 111 Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: :Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0302 DATE: 11/03/17 PROJECT NAME: HARRY'S OF ALLENTOWN SITE ADDRESS: 12404 42 AVE S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: eowg_ ll --N7 Building Division _ Pu�ilic Works 41A PM -- Fire Prevention Structural ll-e� j, -J 13 A -? 1111 Planning Division iL l ❑ Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable n (rno approval/review required) REVIEWER'S INITIALS: DATE: 11/07/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/05/17 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 11"—e$. -t7 Departments issued corrections: Bldg ar Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals roust be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1276 /I 7 Plan Check/Permit Number: D17-0302 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 RECEIVED ❑ Revision # after Permit is Issued CITY OF TUKWILA ❑ Revision requested by a City Building Inspector or Plans Examiner DEC 0 6 2017 Project Name: Harry's of Allentown PERMIT CENTER Project Address: 12404 42 Ave S Contact Person: L.-ke M t,'< , Phone Number: _ 12-5 ' Cie (— (2I'1 Summary of Revision: EAtil 19- p4 -evil; kvi RZ - 21otekt't5 q-o-Lyzer c -'nhiry lGo/A 4 A l/av�`c&o( C�t(ht(4efhms ? `" 'W{ Ott ;q7 c L � ✓� s �^ �, bet,/ 5 (— s 'k— A 1316614.4 OteklA shcvv�_ Cit, s c/—s) Sheet Number(s): 11 6 "Cloud" or highlight all areas of revision includin&date of revisi n Received at the City of Tukwila Permit Center by: "Entered in TRAKiT on I)y W � 7 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: RAINIER INDUSTRIES LTD Washington State Department of Labor & Industries Home .Espanol Contact Search L&I Page 1 of 3 A -Z Index Help Mc L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing RAINIER INDUSTRIES LTD Owner or tradesperson Principals CAMPBELL, SCOTT CURTICE, PRESIDENT CAMPBELL, KAREN LYNN, VICE PRESIDENT SCHOONMAKER, GEORGE W (End: 01/01/1980) SCHOONMAKER, GEORGE W, AGENT (End: 01/01/1980) Doing business as RAINIER INDUSTRIES LTD WA UBI No. 600 523 816 18375 OLYMPIC AVE S TUKWILA, WA 98188 425-251-1800 KING County Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Awnings, Canopies, Patio Covers, Exterior Screens License no. RAINIIL066QP Effective — expiration 11/17/1994— 01/11/2019 Bond CBIC Bond account no. LB6600 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 09/16/2002 10/01/2002 Expiration date Until Canceled Insurance Phoenix Insurance Company, The Policy no. 6300532991 $1,000,000.00 Received by L&I Effective date . 01/24/2017 12/31/2016 Expiration date 12/31/2017 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600523 816&LIC=RAINIIL066QP&SAW= 12/8/2017