Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0314 - BOEING #9-101 - STORAGE RACKS
BOEING #9-101 9725 E MARGINAL WAY S BLDG 9-101 D17-0314 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0003400018 Permit Number: D17-0314 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: Permit Expires On: Project Name: BOEING #9-101 12/13/2017 6/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH PO BOX 3707 MC 46-88 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 CHICAGO, IL, 60606-1596 BOEINC*294ML Phone: (253) 350-5522 Phone: (312) 544-2535 Expiration Date: 1/18/2019 DESCRIPTION OF WORK: RACKING Project Valuation: $8,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $480.94 Occupancy per IBC: F-1 Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: /2-1(3(/7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grantin: of this permit does not presume to give authority to violate or cancel the provisions of any other state or to al I-ws regulating construction or the performance of work. I am authorized to sign and obtain this develop r enter i and agree to the conditions attached to this permit. Signatur Print N ri (T stow Date: (3 17/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception: 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: �J t Date Application Expires: `L t<6 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 9725 E. marginal way s Tenant Name: Boeing co PROPERTY OWNER Name: John Murdoch /Mark Clement*- Boeing co. Name: The Boeing co. John Murdoch City: Seattle State: Wa Zip: 98124 Address: PO Box 3707 MC 46-88 Email: John.s.murdoch@boeing.com City: Seattle State: Wa Zip: 98108 CONTACT PERSON - person receiving all project communication Name: John Murdoch /Mark Clement*- Boeing co. Address: Po box 3707 MC 46-88 ' City: Seattle State: Wa Zip: 98124 Phone: (253) 350-5522 Fax: (206) 617-2944 Email: John.s.murdoch@boeing.com GENERAL CONTRACTOR INFORMATION. Company Name: The Boeing company- John Murdoch Address: PO. Box 3707 MC 46-88 City: Seattle State: WA Zip: 98124 Phone: (253) 350-5522 Fax: Contr Reg No.: BOEINC*294ML Exp Date: 01/18/2019 Tukwila Business License No.: H:\Applications\Forms-Applications On Line N.2011 Applications\Permit Application Revised - 8-9.11.docx Revised: August 2011 bh King Co Assessor's Tax No.: 5624201032 Suite Number: 9-101 Floor: 1 New Tenant: ❑ Yes ❑ ..No ARCHITECT OF RECORD Name: John Murdoch Company Name: Boeing Co City: Seattle State: WA Zip: 98124 Architect Name: Scott Chin Address: PO box 3707 46=88 City: Seattle State: WA Zip: 98108 Phone: (206) 612-6953 Fax: Email: sung.yu.cho.boeing.com ENGINEER OF RECORD Name: John Murdoch Company Name: Boeing Co City: Seattle State: WA Zip: 98124 Engineer Name: Sung Cho Address: PO box 3707 46-88 City: Seattle State: WA Zip: 98124 Phone: (206) 612-6953 Fax: Email: sung.yu.cho.boeing.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: John Murdoch Address: PO. Box 3707 mc 46-88 City: Seattle State: WA Zip: 98124 Page 1 of 4 BUILDING PERMIT INFORMAT►.,S — 206-431-3670 Valuation of Project (contractor's bid price): $ 8,500 11 Describe the scope o).Wdrk¢(please provide detailed information): ��i ' .¢ �� rU Will there be new rack storage? 0 Yes Existing Building Valuation: $ ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: . Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? D Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IZ Sprinklers Z Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I Floor 295,878 880 b f rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deek Uncovered Deck PLANNING DIVISION: . Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? D Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IZ Sprinklers Z Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INF(ixMATION 206-433-0179 Scope of Work (please provide detailed information): Install 2 new pallet rack at mechanical room on 9-101 bldg. NO COMUSTIBLE MATERIAL TO BE STORED IN RACKS Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District 0 ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View 0 .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) El .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance 0 .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) • Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Ekcavation/Fill - Right-of-way -❑ Non Right-of-way El El ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank ❑ .. Grease Interceptor E l ...Cap or Remove Utilities El.. Curb Cut ❑ .. Channelization El ...Frontage Improvements El .. Pavement Cut ❑ .. Trench Excavation El ...Traffic Control ❑ .. Looped Fire Line El .. Utility Undergrounding ❑ ...Backflow Prevention - Fire. Protection Irrigation Domestic Water 17 ❑ ...Permanent Water Meter Size... 17 WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size 77 WO # 0 ...Deduct Water Meter Size El ...Sewer Main Extension Public El Private El E l ...Water Main Extension Public ❑ Private El 11 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) El ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES.- - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THATI HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 'BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/21/2017 Print Name: Mark Clement Day Telephone: (206) 617-2944 Mailing Address: see above City H:\Applications\Forms-Applications On Line\20I I Applications \Permit Application Revised - 8.9.11.docx Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $480.94 D17-0314 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $480.94 Credit Card Fee $14.01 Credit Card Fee R000.369.908.00.00 0.00 $14.01 DEVELOPMENT $453.33 PERMIT FEE R000.322.100.00.00 0.00 $272.02 PLAN CHECK FEE R000.345.830.00.00 0.00 $176.81 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $13.60 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R12845 0.00 $13.60 - $480.94 Date Paid: Tuesday, November 21, 2017 Paid By: MARK CLEMENT Pay Method: CREDIT CARD 092931 Printed: Tuesday, November 21, 2017 12:45 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project:Type gg"� of Inspection: Address: Date Called: Special Instructions: ►� o p1 -1<O( .244-‘4, Dat anted: `` LL 3"1,14 -PI a.m. p.m. Requester: _//l Phone No: ZS 3 Z-93 aa 4 2— Approved per applicable codes. D Corrections required prior to approval. COMMENTS: COMMENTS. L-N`/� 4/7:ACet,21 Inspector: i�� `- Q Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 611 03% 14 6300 Southcenter Blvd., #100. —! Permit Inspection Request Lin (206) 438-935 8188 (206) 431-3670 Project:(�� Type of Inspection: aPaki Address:1 clic 6 ,t� ,Vi. Date Called: Special Instructions: 1...)%66,t— i q^Iat Date Wanted: 3..11 - 6 a.m p.m. Requester: Phone No: gaao g-ct ( ❑ Approved per applicable codes. orrecti.. r. - . - .val. COMMENTS: /e eArrL.- ,mss i Inspector: .6 l Date: 7� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. DAILY INSPECTION REPORT Report Number: Service Date: ?/'t he Inspection Type: r /e. Client MaYES TESTING ENGINEERS Lynnwood, WA (425) 742-9360 Tacoma, WA (253) 584-3720 Portland, WA (503) 281-7515 Alkrracon COMPANY Engineer: Architect: Contractor: Pro' ct t c u I W. -(.j � - r o l Project Number: Permit Number: Weather: /vtc rtJZ t -air. Ll?) v t n t A! G- Z A J 5 r,y Lc Ttc/ ) O F 1•- ZL r T- % "4- L L(1 -4-c (c5 `� /U1 (ticc✓(- `'tl - I S) . vc,--)22 Zt')# c 7 a p -e- ct vJet CIO E- Pr H u k/' pNc I-10 21 v ____ C'd� (Z � A A rGA RECEIVED CITY OF TUKWILA APR 18 2018 PERM CENTER To the best of our knowledge, all items inspected as noted above were in general e: 'es Conformance with the approved plans and specification. 0 No ❑ Preliminary Observations ❑ Deficiency Corrected — Repor No. Arrival: Departure: Travel Time: Total: Ci - rL E % rtvi t, P 5 TERRACON FIELD REPRESENTATIVE REVIEWED BY THIS REPORT IS CONSIDERED PRELIMINARY AND SUBJECT TO CHANGE PENDING REVIEW BY OUR PROJECT MANAGER. FINALIZED FORM SHALL BE ISSUED WITH PROJECT MANAGER SIGNATURE. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written cons€Pit of our company. BY G. OHANIAN DATE . 10-23-17 SUBJECT RACK DESI(N & EN(INEERING CO. 412 WEST BROADWAY, SUITE #204 GLENDALE, dA. 91204 TEL:(818)240-3810 E- AII: rackdepign1egmaiil.com SHEET NO. 1 JOB NO. RD -19185 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: THE BOEING CO. 925 EAST MARGINAL WAY SOUTH BUILDING 9-101 TUKWILA, WA 98108 PER IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3 RMI/ANSI/MH 16.1:2012 STORAGE RACKS CAPACITY: 5000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -19185 FILO REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 201 City of Tukwila BUILD( ' • EXPIRES 12-26-17 RECEIVED CITY OF TUKWILA NOV 21 2017 'ERMiT CS.NTEk BY G. OHANIAN DATE. 10-23-17 SUBJECT RACK DESIGN & ENGINEERING CO. 412 WEST BROADWAY, OUITR #204 (LENDALE, dA. 91204 TEL:(818)240-3810 rackdeptIgn1Ogmafl.com SHEET NO. 2 JOB NO.. RD -19185 144" 24 - I 4 FRONT VIEW 0 L, to R to too 1 40" SIDE VIEW BEAM DESIGN LOAD PER BEAM + 25% IMPACT LOAD =5.13 (5.0 Kx.88)+(2.5 Kx.25) = .0 = 2.5 K lxBEAMS Sx=1.65 M= 8 =45 "K Fy =55 KSI' S R= 1,37<1.65 A— 5xwL4 =.65"<��_��L_ =.80 384.1x.E 8 SEISMIC DESIGN V= RxxW IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2012 S os =1.00 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. RMI 2.6 AND 2.6.3 R=4 BRACED W=D.L.+ 3 PRODUCT LOAD LOAD PER COL. — 2x5.0 K —5.0 K 2 cm. P=.2 DL+ (5.0 Kx0.75)=4.0 K W=.2DL+ (5.OPLx0.67)= 3.6 K \LONGIT. '42 K VTRANS..63 K LONGIT. SEISMIC .42K 9.5 "K 6.3"K 9 5"K BY G. GHANIAN DATE. 10-23-17 SUBJECT RACK DESIGN & ENGINEERING CO. 412T BROADWAY, FlUITE LENDALE, dA. 91204 f 204 E-MAIL:TEL:(818)240-3810 MAILrackdeglfgnlegmafl.com SHEET NO. 3 JOB NO.. RD -19185 COLUMN DESIGN x- 3 --x I t=.105" Fy=55 KSI Ae=.91 I x=1.36 Se=.9 rx=1.2 ry=1.1 COMBINED STRESS RATIO Pex=(2 =59.0 C2c=1.8 f2aP __ ab=1.67 ox=1- Pex .88 Crnx=.85 _48x1.7 =68 rx 1.2 36 _ =33 Y • Mn=Se .Fy= 50 Oc.P+Mn.ax Qb.Cmx.M =.51<1 2 Fe= i ) 2 - 63 X = Fy /Fe = 0.93 rx F n=F y(.658 Aa )=38 KSI Pn= Fn .Ae = 35.0 K 4.0K 9.5� BASE PLATE ANCH. TENSION = 0 IQ ANCHOR SHEAR = .21 K I0 01 a. (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT -TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.10x1x65=3.4K BEARING CAPACITY OF COL. HOLE 6.3 "K 7/16"0 RIVET A = .1 Fy = 79 KSI Pa=.1x79x.4 = 3K Ma = (3.0 Kx4")+(1.5 Kx2") = 15.0 "K 3 PIN CONN. CONN. = .01 xw12 3.6 "K MEND M = 7.9"K SEISMIC M=11.5"K TOTAL 7.9"'( Ac<1.5 7.9"K 9.5 "K By G. GHANIAN DATE. 10-23-17 SUBJECT RACK DESIGN & ENGINEERING CO. 412 rfEcriT BROADWAY, SUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 E—�ltAIL: raokdeglign1 gmail.00m SHEET NO. 4 JOB NO.. RD -19185 OVERTURNING MOT=.63Kx2 x114"x0.66 =95"K COL. MR = 4.0 Kx40" = 158"K NO UPLIFT LOAD TO DIAGONAL P = .63 Kx2tO 40 = 1.4 K Fy=55 KSI Ae=.26 rx =.48 L= 46" Pa = 4.1 K CHECK WELDS Pn= L.t.F„ =.06x1.5"x65 =5.9 K 0= 2.35 5 9 K 2 5x _ 0 2.35 . SIDES .0 K CHECK SLAB 4000 — 40°' 1000 — 63K 4.0x144=576 °" M= (12 ) x1000x 2 x12=2344 "# s= 12x62 = 72 6 2344 • 33 <1.6 2500 =80 . 72 4.0K 4.0K .63 K rn 40" TOP LEVEL 100% LOADING W= 0.2m+2.511=2.7 K LOAD PER COL. V= .48 K MOT =.48 Kx2 x96"= 93"K COL. MR = 2.7 Kx40" = 109"K NO UPLIFT BOTH SIDES TYP. t=.06" 4000 # 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL 2/7/2019 City of Tukwila Department of Community Development MARTIN PROBST PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. D17-0314 BOEING #9-101 9725 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/17/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/17/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Permit Technician File No: D17-0314 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 28, 2018 Martin Probst PO Box 3707; M/C: 46-208 Seattle, WA 98124 RE: Request for Extension #1 Permit Number D17-0314 Dear Mr. Probst, This letter is in response to your written request for an extension to Permit D17-0314. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through March 17, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, lit V4 achelle Ripley Permit Technician File: Permit No. D17-0314 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov The Boeing Company Facilities & Asset Management Supply Chain Operations Code Compliance & Permitting Friday, August 10, 2018 GG-GG-PCTA-180308 City of Tukwila Dept. of Community Development Attn: Rachelle Ripley 6300 Southcenter Blvd., Suite 100 Tukwila, WA. 98188-2544 Subject: Dear Mrs. Ripley; Permit Extension Request Project#. D17-0314 Project Description: 9-101 Pallet Racks The Boeing Company Per our records we show that Permit# D17-0314 expires on 9/17/2018. This permit is for Boeing's pallet rack installation project. Although the special inspections from Mayes Testing were completed the final inspection must still occur. The project manager for this project is out of the office until mid September. I am unable to coordinate with that Project Manager until his return and therefore request your consideration for an extension of the permit due date. Work is on-going and has not been abandoned. Per Section 105 of the International Building Code "[A] 105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The building official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated." Would you please grant The Boeing Company an extension of 180 days for this project? You have my appreciation in advance of your consideration on this matter. Best Regards, Martin R. Probst Code Compliance & Permitting The Boeing Company PO Box 3707: Mail Stop 46-208 Seattle, WA 98124 206-852-4985 Author (MRP) Request for Extension # I Current Expiration Date: 1• I 1 0 Extension Request: y Approved for / days Denied (provide explanation) l Si nature/Initials 8/1/2018 City of Tukwila Department of Community Development MARTIN PROBST PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. D17-0314 BOEING #9-101 9725 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/17/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/17/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c 1 ' 'rpy Permit Technician File No: D17-0314 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0314 PROJECT NAME: BOEING #9-101 SITE ADDRESS: 9725 E MARGINAL WAY S DATE: 10/22/17 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: #wv e\ Building Division Public Works AiA AP Fire Prevention Structural Lt - Planning Division ❑ ❑ Permit Coordinator ri PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/28/17 Structural Review Required REVIEWERcS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) 12/26/17 Notation: REVIEWERc6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 BOEING COMPANY, THE Washington State Department of Labor & Industries Home. Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 9 wxit- A-Z Index help My i.FeI Workplace Rights Trades & Licensing BOEING COMPANY, THE Owner or tradesperson LOHR, MICHAEL Principals LOHR, MICHAEL, SECRETARY MCNERNEY, W (JAMES), PRESIDENT (End: 01/13/2017) WOLTER, CHRISTOPHER, TREASURER (End: 01/16/2015) READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER -(End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) WA UBI No. 178 005 030 100 N RIVERSIDE M/C 5003-4027 CHICAGO, IL 60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BOEINC*294ML Effective — expiration 07/13/1971— 01/18/2019 Bond Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 12/8/2017 SYM ICI\I�Y vIAP PROJECT SITE FROM DOWNTOWN SEATTLE ❑o 0 900 rct c -n rn 99 EXIT 158 JBOE• TING ACCESS RDNv4N v 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT 599 TUKWILA DEVELOPME\TAL CENTH FROM KENT\ & AUBURN NO SCALE 900 REVISION A HAND TRIM RELOCATION B PALLET RACK INSTALLATION J#57655800 WO#13543729 C PALLET RACK INSTALLATION WO# W1609835 BY WEM SC SC APPROVED DATE SYM BOEING WORKPLACE SERVICES BUILDING 9-101 PALLET RACK INSTALLATION BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 A- EA v1AP 3UILD1\3 ADDKSS: 9725 EAST vAKI\AL WAY SOUTH TU<WILA, WASHI\GT0N NO SCALE 9-101 3UILDI\G LOCATION REVISION BY APPROVED DATE 10.03.07 10.17.12 05.06.13 D PALLET RACK INSTALLATION WO# W5325276 SC 11.15.17 GE \E AL \OTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO BOEING CONSTRUCTION MANAGER OR FACILITY ENGINEER AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHEC <LIST CHECK BOX • THESE DRAWINGS CONFORM TO THE 2015 I.B.C. CODES AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® ROOMS LABELED PER OCCUPANCY PER I.B.C. 302.1. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: L 1. GENERAL PERMIT (SHELL & CORE) ❑ 4 SETS OF STRUCTUAL REPLACEMENT DRAWINGS ® 2. TENANT IMPROVEMENT (NON—STRUCTURAL): ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION/SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: INSTALL TWO (2) 3'-4"W x 12'-0"L x 12'-0"H PALLET RACK SIDE BY SIDE AT MECHANICAL ROOM IN BUILDING 9-101. THERE WILL BE TWO (2) SHELVES AT 4'-0" AND 8'-0" ELEVATION FROM FINISH FLOOR. THE PALLET RACK WILL BE STORING METALS IN TUB SKIDS AND NO FIRE SPRINKLER SYSTEM IS REQUIRED. D ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. CHO CHECKEIS S. CHO DATE 11.15.17 11.15.17 SUBTITLE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT F.''•i°isio"Is will require a new plan submittal • and may include additional plan review fees. COPY Permit No. flO3H Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of = y code or ordnance. R ipt of awed F ed: I SEPARATE PERMIT R C:WIRED FOR: Ct Mechanical lectrical (�FP�rrtbing Gas Piping City of Tukwila SUILD!NO DIVISION City of Tukwila BUILDING DIVISION DAWI\G I\DEX SHEET N0. DRAWING N0: SHEET TITLE REV- N0. DATE GO 9-101—GO TITLE SHEET D 11.15.17 1S44 09-101-1S44 FOUNDATION PLAN (P—S/22-23) B 11.15.17 — RD -19185 STORAGE RACK DETAILS (VENDOR'S DRAWING) — 10.23.17 RE`. (EWE', FOR COD: COMVM' RPRO °; LIANCE ED DID 0 6 ►017 CODE SU vl VIAY City of Tukwila BUM LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE EFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC TUKWILA 2015 I.B.C. CODES AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE B, NON-COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 295,878 (UNLIMITED PER IBC 507.3) 713,829 1,116, 306 50,910 713,829 55,689 60 SF OF STORAGE 111 FT. MAXIMUM 2 OVERALL (NO CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S C S S USE GROUP I, DESIGN CATEGORY D OF RECEIVED CITY OF TUKWILA NOV 21 2017 E" v INTER 1 INKL TNRO HOU Ss = 1.42, S1 = 0.49 TITLE SHEET CURRENT REVISION WO# W5325276 SYMBOL DATE 11.15.17 ENGINEER CHECKED APPROVED APPROVED TITLE PERMIT MASTER INSTALL PALLET RACK BUILDING 9-101 SHEET GO JOB NO. W5325276 COMP NO. DEV. CENTER, WA DWG NO. 9-101—GO m M SYM P.25 P.6 x.25 6 >- U o z U REVISION BY APPROVED DATE SYM DART AL SCALE: 1/8" = REVISION \DAT 0\ BY DLA APPROVED DATE A UPDATE & CORRECT DRAWING B INSTALL PALLET RACK WO/ W5325276 SC SC 05.11.11 11.15.17 JNG U. cc, 5 . r�r W4sti. 0 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY •7/1 DEPT. DATE DRAWN J. PEARSON DATE CHECKED S. RANGARAM SUBTITLE L -G \D # > NON SPECIFIC, NOTE APPLIES TO ROOM SPECIFIC, NOTE APPLIES TO SPECIFC ITEM G - RAL \OT -S 1. ALL WOR K PER 2015 IBC EDITION. 2. CONTRACTOR/MILLWRIGHT SHALL VERIFY ALL DIMENSIONS IN THE FILED PRIOR TO FABRICATE OR INSTALL. ANY VARIATIONS FROM THE DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE FACILITY ENGINEER. DIMENSIONS ON DWGS ARE APPROXIMATE. 3. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 4. LEAVE WORK & STAGING AREAS CLEAN & UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 5. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 6. REMOVE ALL TOOLS & MATERIALS FROM THE WOR K AREA. 7. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. 8. NO COMBUSTIBLE MATERIAL SHALL BE STORED IN THE PALLET RACK AND NO FIRE PROTECTION SYSTEM IS REQUIRED. R =R \C DRAW \GS RD -19185 STORAGE RAC CO\STR,CT K DETAILS 0\ \OT -S INSTALL PALLET RACK @ ANNEX MECHANICAL ROOM (W0# W5325276) INSTALL TWO (2) 12'-0" SECTION PALLET RAC<S. SEE PALLET RACK INSTALLATION DETAIL RD -19185. SPECIAL INSPECTION FOR ANCHOR BOLTS INSTALLATION. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 06 211 city Tu ti a BUILDING DWI( ti D E H J Ja N S Gs) CE) T I T T 1510 1S11 1S12 1S13 1S14 1S15 1516 1S17 1S18 1S19 1S20 1S21 1 1S22 I 1S23 1S24 1S25 1S26 1S27 1S28 1S29 1S30 1S31 1S32 1S33 1S34 1S35 1S36 I 1S37 1S38 1S47 1539 1S40 1541 1S42 1S43 1S44 r 1S45 RECEIVED 1,S46 1S48 ri FOUNDATION PLAN (P -S/22-23) CITY OF TUKWILA 21 2017 SCALE: NONE 31y CURRENT REVISION SYMBOL PERMIT CENTER DATE 15 19 20 21 22 ENGINEER H. SHAHBAZIAN CHECKED H. SHAHBAZIAN APPROVED W.E. MOOR APPROVED D. SEPTELKA 10.13.94 TITLE STRUCTURAL MASTER BUILDING 09-101 COL. P -S/22-23. DEV. CENTER, WA SHEET 1 S44 JOB NO. DCA -94092 COMP NO. DWG NO. 09-101-1544 94092X.L/492S0141 TYP 1/41'0 SAFETY LOCK (1000 # CAPACITY) 1 3/4" m gilitc.:,,,,,,..:.:,„:"%c:.,,,.,:::.:. p C f p 6 OC s p 6p 0 6 6 qq 0 00 0 0 0 0 00 C�oooao sagaaoo00000oa/J m AJ<Ali- ‘11111tA° 0 41:11Milittf::=7:,:lef:Inbabab.:11- Iiiihxy4mm \ \ x y1 i I Ln BOTH SIDES NP- 1 8 1.5 \ \ \ / % ❑ 4 �� i lJ s� x c° i I I t-0.07" 1 1/8 (iZ (� 11/2., B"Bai 3" tI -, o 3o �.� -.,...... �1► 2 3/4" —t" ❑ .z,_ ._ _ .. .., 01 Ali • � r- , , ... 10 MI " I • °: r_ .. i. :"> �' ° •. .. _ ' e• : tet- e t=.06" / \ SEC. A -A I _ t=.105" � ! --�— I i I i lo _ p ° ° _•� °. e'er ps _' aC ., A .< s, ' •. y ' g �' • > p• > • A \ ,! TYP 1 O m. 1�0 / / / / I p ' • .-* ° ' • ''' - ° f .. \ t=1/2" TYP 1 /8 X1.5" / / / ❑ It $ " N o0 r / / \ / (2)-1/2"0 ANCHOR BOLTS PER BASE PLATE413. 3 1/4" EMB., (SEE NOTE NO. 4) , cNi SEC. B -B 7/161'0 RIVET ASTM A576 -90B g — t=3/16" HOT—WROUGHT UNS G10100 GRADE C-1010 , PLATE DETAIL (ii 1 BRACING DETAIL (f, PIN CONNECTION (3) GENERAL CONFIGURATION (4JBASE I REVIEWED FOR BODE COMPLIANCE APPROVED • DEC 0 6 2011 City of Tukwila BUILD.i 144" 40" NOTES: 1—DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2015, ASCE/SEI 7-10, ACI 318-14, RMI/ANSI MH 16.1:2012 2—STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) 3—NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #01649 (E70XX ELECTRODES) 4—ALL ANCHORS HILTI KB TZ ESR 1917 SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6—STORAGE RACK CAPACITY: 5000 #/ level 7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (5000 #/ level) 8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10'-0" OF HEIGHT 9—THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10—STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY RECEIVED CIT OTlJKWILA NOV 21 2017 PERMIT CENTER ) n... b 514 1/1 to 11611 1 © ■ 10 "� O 0, . RACK 111K . , ug w44046 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 C? } �� SCALE NONE DRAWN BY: _A.S;/ _ °O \ \ \ ' DATE 10-23-17 PROJECT THE BOEING CO. 9725 EAST MARGINAL WAY SOUTH, BLDG. 9-101, TUKWIILA, WA 98108 • STORAGE RACK DETAILS JOB N0. RD -19185 SHEET Na FRONT VIEW SIDE VIEW