Loading...
HomeMy WebLinkAboutPermit D17-0332 - DZ DEVELOPMENT - BATHROOM AND BEDROOMDZ DEVELOPMENT 5110 S 163 PL D17-0332 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 8700500050 5110 S 163RD PL DZ DEVELOPMENT DEVELOPMENT PERMIT Permit Number: D17-0332 Issue Date: 4/23/2018 Permit Expires On: 10/20/2018 Owner: Name: Address: Contact Person: Name: JOHNSON CALVIN M 5110 S 163RD PL , TUKWILA, WA, 98188 DAVID HILLS Address: '. 1609 5TH ST NW , AUBURN, WA, 98002 Contractor: Name: Address: License No: Lender: Name: Address: JACOBSEN REMODELING LLC 116 16TH AVE , KIRKLAND, WA, 98033 JACOBRL831L3 DZ DEVELOPMEN 116 16TH AVE , KIRKLAND, WA, 98033 Phone: (253) 334-4280 Phone: (206) 384-9298 , Expiration Date: 5/23/2019 DESCRIPTION OF WORK: PERMITTING BATHROOM AND BEDROOM THAT ALREADY EXISTS Project Valuation: $5,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $340.93 Occupancy per IBC: R-3 Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: k-21-40 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: "04 Date: 0 --?/71 Print Name: DA{/r'l kh (1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING t CITY OF TUKW ILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. J7I1/ O'/Yii Project No. Date Application Accepted: 1 1 Date Application Expires: (0 IC ci (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 5—/ 10 S • 1 1o3 fest Ptw«. Suite Number: Floor: Tenant Name: Voat.. �'3"' PtUM 071 V l New Tenant: ❑ Yes ❑.. No PROPERTY OWNER i , Name: VAVia RIA5 Name: 0 2... Dave] 0 pn, III+ L- L C. Address: 1609 S+` S4- ti E -- Address: 11 b f tori,.. L 0 City: City: /1 uibure\ State: dpi. City: `,`rk nA State: wpr Zip: 61,2033 CONTACT PERSON — person receiving all project communication i , Name: VAVia RIA5 Address: 11.6 i b4' A -o J Address: 1609 S+` S4- ti E -- State: W k City: City: /1 uibure\ State: dpi. Zip:(,isay, Phone: 253.334-14220 Fax: Email: o \v(. s3e.,��a;\ . ,o+. - (loc.:, Exp Date: J GENERAL CONTRACTOR INFORMATION Company Name: , t Jato6sen RQr+aJIe\ c,‘ LL C - Address: 11.6 i b4' A -o J City: k; coo State: W k Zip: 9c5.033 Phone:,253"33'x_ Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: State: Zip: H:Applications \Forms -Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh ARCHITECT OF RECORD Name: ®Z Devejoim,(41. Company Name: K r_rn State: uth. Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: ®Z Devejoim,(41. Company Name: K r_rn State: uth. Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: ®Z Devejoim,(41. Address: Mc) , G i A_ 4411._City: K r_rn State: uth. Zip: 004 Page 1 of 4 BUILDING PERMIT INFORMATIC 206-431-3670 c� Valuation of Project (contractor's bid price): $ 5000Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Pot- NI 4 #1(1 110wn544V(S Wr6Z eft. 14 At ' t rY'a)(ts 41) Will there be new rack storage? ❑ .... Yes �No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm Er None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes ; attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms-Applications On Line\2012 Applications\permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor i326 2nd Floor `30b 3rd Floor Floors thru Basement Accessory Structure* Attached Garage LOIS Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm Er None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes ; attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms-Applications On Line\2012 Applications\permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO._.1ATION — 206-433-0179 Scope of Work (please provide detailed information): PerrA,\AAe`iCiS Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View ❑... Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑. 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0...Storm Drainage .. Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ .. ❑ .. ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public 31 WO # WO # WO # Private 0 Private 0 ❑...Grease Interceptor 0... Channelization ❑...Trench Excavation ❑... Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # ❑ .. Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water ❑ .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES — a - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.• Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: --1/� Date: / 2/7 /1 Print Name: Otavi Ui «S Day Telephone: 213 -33 LI— Y 71'6 Mailing Address: ? Loci 3- .s+ N E AV burn 01 Pr 1 i®U'2 H:1Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $602.92 D17-0332 Address: 5110 S 163RD PL Apn: 8700500050 $340.93 Credit Card Fee $9.93 Credit Card Fee R000.369.908.00.00 0.00 $9.93 DEVELOPMENT $321.40 PERMIT FEE R000.322.100.00.00 0.00 $192.06 PLAN CHECK FEE R000.345.830.00.00 0.00 $124.84 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $9.60 TECHNOLOGY FEE I R000.322.900.04.00 0.00 $9.60 PG17-0171 Address: 5110 S 163RD PL Apn: 8700500050 $261.99 Credit Card Fee $7.63 Credit Card Fee I R000.369.908.00.00 0.00 $7.63 PLUMBING $242.25 PERMIT FEE R000.322.100.00.00 0.00 $209.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $12.11 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R13037 0.00 $12.11 $602.92 Date Paid: Friday, December 15, 2017 Paid By: DAVID HILLS Pay Method: CREDIT CARD 01595G Printed: Friday, December 15, 2017 12:07 PM 1 of 1 CI (SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 b►7-033z Project: i 02-DOve.lo AT T e of Ijnsp ct,�on: 1 t'r4) no f r L Address: 51/0 j- // 3'� Pt, Dae Calle 5- - 20/$' Special Instructions: Date Wanted: a.m. {_g. - p.m. Requester: Z5--3 - 34/ -4/ z-0 ice, Phone No: Approved er aoplica odes. LI Corrections required prior to approval. Inspector: 3 SO Date8,2001 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: OZ D l/1L®Prl)°r- Type of Inspection: Address: 57/0 /4, j) Pi. Date Called: Special Instructions:1 6 NG G�-t- 55'35-cAiL Date Wanted: a.m: 6 a 1� p.m. Requester: 0411t• D Phone 2.5-3-3*- 1 EApproved per applicable codes. Corrections required prior to approval. COMMENTS: l ► rtL�� *#L SS Gt.i-- 1!'riQrIUr SC41- ‹s• Inspectorgcze /% Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development December 26, 2017 DAVID HILLS 1609 5TH ST NW AUBURN, WA 98002 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0332 DZ DEVELOPMENT - 5110 S 163RD PL Dear DAVID HILLS, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Codes on the cover sheet reference outdated 2012 codes. Revise code references to show compliance with current 2015 codes to include any changes to Tables and notes that may have also changed. 2. The plans need to be clearer with details about what portions are altered. All plans shown appear to be basically the same layout and some items shown in the legend are not part of the plan. Please clarify. Mark, cloud or note which walls, doors, windows, etc. that are altered. Provide details to show cross section of exterior wall construction to indicate size of framing and insulation per code. 3. Specify egress window for the bedroom. Also note the proposed ledger at the bedroom window exceeds the allowed height for egress windows. A sill height shall not be more than 44 inches above the floor. Provide the size of the window and if below grade indicate a window well with size details. Bedroom window shall meet egress requirements. (IRC SECTION R310) 4. Show the SD CM within the close vicinity of the bedroom door. (IRC 314.3 & 315.3) Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D17-0332 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0332 DATE: 04/11/18 PROJECT NAME: DZ DEVELOPMENT SITE ADDRESS: 5110 S 163RD PL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: A/S— AttIC 'L --t)--0 Building Division L. Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/12/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections enter d in Reviews) Notation: 4-e ay. DUE DATE: 05/10/18 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: [Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 °ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0332 PROJECT NAME: DZ DEVELOPMENT SITE ADDRESS: 5110 S 163RD PL X Original Plan Submittal Response to Correction Letter # DATE: 12/19/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division (a=te,( 17.1 bllIgI+1 Pu1bllic Works AyA._ Fire Prevention p Planning Division Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 12/19/17 • Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWERQS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/16/18 Approved ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews Notation: Denied (ie: Zoning Issues) REVIEWERcS INITIALS: DATE: ;Permit Center Use Only CORRECTION LETTER MAILED: 1 (o`( Departments issued corrections: Bldg Lr Fire ❑ Ping 0 PW ❑ Staff Initials: W �� 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: $00/it Plan Check/Permit Number: D 17-0332 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: DZ Development Project Address: {5110 S 163 P1 Contact Person: D 1 v d h1 Is Phone Number: RECEIVED CITY OF TUKWILA APR 1 1 2018 PERMIT CENTER Zy3 3P`1- iu'v Summary of Revision: eta r t ed (\ 4,5 Ix, S ,Ini �v1 ltc,{C L4, el arc- �t 'G^') n�-c/- 4 ` 'L axis 4-i ]e,s e, 4 4-7 Lv v} (+ =a c 1 ln-rio3/4.. o' Beit-401*1"- C- vr.. -fr4<„7 f^-/4 4,1 Pg.cal rG it c-4^-#1.1 Sheet Number(s): 1 "Cloud" or highlight all areas of revision including dat of rvision Received at the City of Tukwila Per 't Center by: kl Entered in TRAKiT on 14. \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: JACOBSEN REMODELING LLC 1ibme Esprain/ Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & industries Page 1 of 2 A -Z Index Help My1,10 Workplace Rights Trades & Licensing JACOBSEN REMODELING LLC Owner or tradesperson Principals JACOBSEN, DEAN GREGORY, PARTNER/MEMBER Doing business as JACOBSEN REMODELING LLC WA UBI No. 603 143 136 116 16th Ave KIRKLAND, WA 98033 206-384-9298 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JACOBRL831 K3 Effective — expiration 05/23/2017— 05/23/2019 Bond Wesco Insurance Co Bond account no. 46WB086256 $12,000.00 Received by L&I Effective date 05/23/2017 05/22/2017 Expiration date Until Canceled Insurance Security National Insurance Policy no. NA119270000 $1,000,000.00 Received by L&I Effective date 05/23/2017 05/22/2017 Expiration date 05/22/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603143136&LIC=JACOBRL831 K3&SAW= 4/23/2018 4 - - J I A GENERAL N 5: Off' REVISION TABLE O Pn ii w a FIREBLOCKING: y DRAFTSTOPPING: REVISED BY IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING 61-1ALL BE PROVIDED TO CUT OFF BOTH IN COMBUSTIBLE CONSTRUCTION WHERE THERE 15 USABLE SPACE BOTH AB0vE AND BELOW BUILDING CODES: - VERTICAL AND HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOP5 SHALL BE INSTALLED BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. 2015 INTERNATIONAL BLDG. CODE (IBC) FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAME CONSTRUCTION IN THE FOLLOWING DRAFT -STOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) LOCATIONS: AREAS. WHERE THE ASSEMBLY 15 ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES MEMBRANE BELOW, AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES REQUIRED ADDITIONAL SUBMITTAL FROM MANUFACTURERS 1.1 VERTICALLY AT THE CEILING AND FLOOR LEVELS:UNDER THE FOLLOWING CIRCUMSTANCES: 12. HORIZONTALLY A7 INTERVALS NOT EXCEEDING 10 FT. AT TIME OF PERMIT SUBMITTAL: 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES I. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. ILI I. MANUFACTURING FLOOR JOIST DESIGN AND LAYOUT. SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 2. FLOOR FRAMING IS CONSTRUCTED OF TRJSS-TYPE OPEN -WEB OR OTOOF THE PERFORATED MEMBERS. 2. MANUFACTURING ROOF TRUSS DESIGN AND LAYOUT. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BTM p SITE WOW RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.1.(I/2' GWR) 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES WIRES AT CEILING AND FLOOR MATERIALS SHALL 'GYPSUM W R302.12.1 MATERIALSDRAFTSTOPPING NOT BE LESS THAN I. FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1,500 PSF, LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND 130ARD, i' WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY' UNLESS;A SOIL INVESTIGATION BY A QUALIFIED SOILS ENGINEER IS PROVIDED. PRODUCTS OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE SUPPORTED. DR4FTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING 2. EXTERIOR FOOTINGS SHALL BEAR 18' (MINIMUM) BELOW FINISHED GRADE. REQUIRED TO MEET THE ASTM E.136 REQUIREMENTS. MEMBER UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE 3. FOOTINGS TO BEAR ON FIRM UNDISTURBED EARTH BELOW ORGANIC SURFACE SOILS. 5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION 81003.19.2 in X 0 4. BACKFILL MATERIALS TO BE THOROUGHLY COMPACTED. OF A TWO-FAMILY 15 AT THE OF DRAFT5TOP5 SHALL BE MAINTAINED. 6. FIREBLOCKING OF CORNICES DWELLING REQUIRED LINE INSULATION AND MOISTURE PROTECTION INSULATIONNG SEPARATION. FIREBLOCKING SHALL CONSIST OF MATERIALS LISTED IN IRC INSPECTIONS AND ENFORCEMENT Kirao, WA 98033 (206) 38-9298 RUNIT 8302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR INSULATION LOOSE FILL INSULATION MATERIAL 514ALL NOT BE USED 46 A FIREBLOCK UNLESS POSTING OF CERTIFICATE U1SEC R4013 FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN SPECIFICALLY TESTED IN THE FORM AND MANNER INTENDED. A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED ACCORDANCE WITH SECTIONS 8302.10.1 THROUGH R302.10.5. FLASHING. DESIGN PROFESSIONAL AND POSTED ON A WALL IN THE SPACE WHERE THE FURNACE IS R302.10.I INSULATION LOCATED, A UTILITY ROOM, OR AN APPROVED LOCATION INSIDE THE BUILDING. WHEN APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION INA INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS AND LOCATED ON AN ELECTRICAL PANEL, THE CERTFICATE SHALL NOT COVER OBSTRUCT THE MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER vAPO-PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, VISIBILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LABEL, OR OTHER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED T MEMBRANES USED ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES, AND ATTICS SHALL HAVE A REQUIRED LABELS. THE CERTIFICATES SHALL LST THE PREDOMINANT R -VALUES OF THE AS FLASHING SHALL COMPLY WITH AAMA 111. THE FLASHING SHALL EXTEND TO THE SURFACE ISE: PiAR'� 1 L i)EfIVjIT FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPLISHING SMOKE -DEVELOPED OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSULATION INSTALLED IN OR ON CEILING/ROOF, UTALLS, FOUNDATION (SLAB, BELOW -GRADE REQUIRED FOR: INDEX NOT TO EXCEED 450 WHERE TESTED IN ACCORDANCE WITH ASTN E 84 OR UL 123. WALL, AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES± U -FACTORS FOR INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: EXCEPTIONS: FENESTRATION AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION, AND THE r -r ,fie I. WHERE SUCH MATERIALS AREW INSTALLED IN CONCEALED SPACES, THE FLAME SPREAD 1• EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE DONEIdechanical INDEX AND SMOKE -DEVELOPED INDEX LIMIATATIONS DO NOT, APPLY TO THE FACINGS, OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE ON THE BUILDING. WHERE THERE IS MORE THAN ONE VALUE FOR EACH COMPONENT, THE C iectrical WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR PROVIDED THAT THE FACING 15 INSTALLED IN SUBSTANTIAL CONTACT WITH THE WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR CERTIFICATES SHALL LIST THE VALUE COVERING THE LARGEST AREA. THE CERTIFICATES Cr�Plumbing UNEXPOSED SURFACE OF THE CEILING FLOOR OR WALL FINISH. SHALL LIST 'GAS-FIRED UNvENTED ROOM NEATER,' 'ELECTRIC FURNACE' OR 'BASEBOARD MORE OF THE FOLLOWING. 1.1 THE FENESTRATION MANUFACTURE'S INSTALLATION AND GC,,L 2. CELLULOSE FIBER LOOSE -FILL INSULATION, T1447 IS NOT SPRAY APPLIED, COMPLYING FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION ELECTRIC HEATER,' AS APPROPRIATE AN EFFICI.4NCY SHALL NOT BE LISTED FOR as Piping WITH THE REQUIREMENTS OF SECTION 8302.103, SHALL NOT BE REQUIRED TO MEET THE GA5-FIRED UNVENTED ROOM HEATERSELECTRIC FURNACES OR ELECTRIC BASEBOARD MANUFACTURERS INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT , City of Tukwila SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450 WHERE TESTED IN ACCORDANCE HEATERS. WITH CAN/ULC 5102.2. PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE STILL OF EXTERIOR WINDOW DUCT LEAKAGE TESTING: BUILDING DIVISION AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A 3. FOAM PLASTIC INSULATION SHALL COMPLY WITH SECTION 8316. DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU R5-33, USING THE MAXIMUM DUCT R302.102 LOOSE -FILL INSULATION MANNER A5 TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO LEAKAGE RATES SPECIFIED IN 2015 WSEC SEC. 84033.3. A WRITTEN REPORT OF THE RESULTS LOOSE -FILL INSULATION MATERIALS THAT CANNOT BE MOUNTED IN THE ASTM E 84 OR UL 123 THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN SHALL BE SIGNED BY THE PARTY CONDUCTING rHE TEST AND PROVIDED 70 THE CODE FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND APPARATUS_WITHOUT A SCREEN OR ARTIFICIAL SUPPORTS SHALL COMPLY WITH THE FLAME OFFICIAL. SPREAD AND SMOKE -DEVELOPED LIMITS OF SECTION 8302.10.1 WHERE TESTED IN SIDES. 12 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED WI -DING AIR LEAKAGE TESTING 2015 MEC SEC, R4024 ACCORDANCE WITH CAN/ULC 51022 DESIGN PROFESSIONAL. 13. IN ACCORDANCE WITH OTHER APPROVED METHODS. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY EXCEPTION: CELLULOSIC FIBER LOOSE -FILL INSULATION SHALL NOT BE REQUIRED TO CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS 8402.4.1 THROUGH 8402.4.4_ BE TESTED IN ACCORDANCE WITH CAN/ULC SI022 PROVIDED SUCH INSULATION COMPLIES UNDER STUCCO COPINGS. WITH THE REQUIREMENTS OF SECTIONS 8302.10.1 AND 8302.103. (0� I: 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 8302103 CELLULOSIC FIBER LOOSE -FILL INSULATION4. 1V15101\ CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 2015 ENERGY CODE COMPLIANCE AND OPTIONS CELLULOSIC FIBER LOOSE -FILL INSULATION SHALL COMPLY WITH CPSC 16 CFR, PARTS 1209 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TOA WALL OR FLOOR AND 1404, EACH PACKAGE OF SUCH INSULATING MATERIAL SHALL BE CLEARLY LABELED IN 2015 WSEC: 35 ENERGY CREDITS REQUIRED PER TABLE 4062 201 CO��i 5 ASSEMBLY OF WOOD -FRAME CONSTRUCTION. ACCORDANCE WITH CPSC 16 GFR, PARTS 1209 AND 1404. 6. AT WALL AND ROOF INTERSECTIONS. CREDITS) 18302101 EXPOSED ATTIC INSULATION DNI7 1. AT BUILT-IN GUTTERS. EFFICIEghiERGY BT UILDING ENVELOPE 05 CREDIT) EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL NAVE A CRITICAL PRESCRIPTIVE COMPLIANCE 15 BASED ON TABLE 8402.1.1 WITH THE FOLLOWING RADIANT FLUX NOT LESS 714AN 0.12 WATT PER SQUARE CENTIMETER WEATHER RESISTIVE SHEATHING PAPER: 81032 WATER -RESISTIVE BARRIER ONE LAYER OF 8302105 ESTE MODIFICATIONS: TESTS FOR CRITICAL RADIANT FLUX SHALL BE MADE IN ACCORDANCE WITH ASTM E 910. NO. 15 ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING WITH ASTM D 226 FOR - VERTICAL FENESTRATION U .= 028 TYPE 1 FELT OR OTHER APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER Z 13'\/1,0°11A:\f, 1,1,C 5 0°5, /3rd e ace, ',<v,�i z WA 95 88 INFILTRATION -FLOOR R-38 CONTROL EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, PENETRATIONS IN STUDS oR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELT OR MATERIAL SHALL BE -SLAB ON GRADE R-10 PERIMETER AND WIDER ENTIRE SLAB FLOORS, ROOFS AND WALLS AND ALL SIMILAR OPENINGS SHALL BE SEALED, CAULKED, APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT -BELOW GRADE SLAB R-10 PERIMETER AND UNDER ENTIRE SLAB GASKETED OR WEATHERSTRIPPEp TO LIMIT AIR LEAKAGE. LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN OR ......--.............--No 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS TO -COMPLIANCE BASED ON SECTION R40214: REDUCE THE TOTAL U4 BY 6%. 8102.1 VAPOR RETARDERS REVI_ THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES (N A CLASS I OR II VAPOR RETARDERS ARE REQUIRED ON THE INTERIOR SIDE OF FRAME WALLS MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED 1N IN CLIMATE ZONES 5, 6, 1, 8, AND MARINE 4. SECTION R103.1.1 3a HIGH EFFICIENCY HVAC EQUIPMENT (1.0 CREDIT) -GAS, PROPANE OR OIL -FIRED FURNACE WITH MINIMUM AFUE OF 95ia S�t�NS changes shall be made to the scope �f ��!Drk ��+ithc3tlt rior a P P pproval of EXCEPTIONS: I. BASEMENT WALLSEXTERIOR DOORS UJINOOUJS AND SKYLIGHTS -GAS, PROPOANE OR OIL -FIRED BOILER WITH MINIMUM AFUE of 92% } eK �I�w'�+la ouikiing Dovision_ 2. BELOW -GRADE PORTRION OF ANY WALL PER 2015 U11A5HINGTON STATE ENERGY CODE TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE HEATING EQUIPMENT TYPE quire a neuv pan submittal P' cid may include additional plan review fees. 3. CONSTRUCTION WHERE MOISTURE OR ITS FREEZING WILL NOT DAMAGE THE MATERIALS. 8102.1.1 CLASS 111 VAPOR RETARDER CLASS WINDOWS SHALL BE INSTALLED AND FINISHED IN ACCORDANCE WITH THE MANUFACTURER'S AND TI -4E MINIMUM EQUIPMENT EFFICIENCY, CLASS III VAPOR RETARDERS SHALL BE PERMITTED WHERE ANY ONE OF THE CONDITIONS IN WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE TABLE 8102.1.1 IS MET PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. ALL SKYLIGHTS AND SKY WALLS 70 5a EFFICIENT WATER HEATING (0.5 CREDIT) R102.12 MATERIAL VAPOR RETARDER GLASS. BE LAMINATED GLASS UNLESS NOTED OTHERWISE. -ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL SE SECTION R310 -EMERGENCY ESCAPE AND RESCUE OPENINGS AT 1.15 GPM OR THE VAPOR RETARDER CLASS SHALL BE BASED ON THE MANUFACTURER'S CERTIFIED RATED LESS. 83101 EMERGENCY ESCAPE 'OND RESCUE OPENNG REQUIRED. -ALL OTHER LAVATORY FAUCETS SHALL EE RATED AT 1.0 GPM OR LESS. TESTING OR TESTED ASSEMBLY. THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS ` SPECIFIED: BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN TO QUALIFY TO CLAIM THIS CREDIT,THE BUILDING PERMIT DRAWINGS SHALL SPECIFY CLASS I: SHEET POLYETHYLENE, UNPERFORATED ALUMINUM FOIL ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING, WHERE BASEMENTS CONTAIN THE OPTION BEING SELECTED AND SPECIFY THE MAXIMUM FLOW RATES FOR ALL MORE THAN ONE SLEEPING ROOMS, AN EMERGENCY ESCAPE ANp RESCUE OPENING SHALL CLASS II: KRAFT -FACED FIBERGLASS BATTS. SHOWERHEADS, KITCHEN SINK FAUCETS, 41O OTHER LAVATORY FAUCETS. BE REQUIRED IN EACH SLEEPING ROOM: EMERGENCY ESCAPE AND RESCUE OPENINGS CLASS 111: LATEX OR ENAMEL PAINT. SHALL OPEN TO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TDA LEC R102.13 MINIMUM CLEAR AIRSPACES AND VENTED OPENINGS FOR vENTED CLADDING. DIRECTLY 5c EFFICIENT WATER HEATING (1.5 CREDITS) PUBLIC WAY. -WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING: FOR THE PURPOSES OF THIS SECTION, VENTED CLADDING SHALL INCLUDE THE FOLLOWING EXCEPTION: STORM SHELTERS OR BASEMENTS USED ONLY TO HOUSE MECHANICAL• it b '� ��� MINIMUM CLEAR AIRSPACES. OTHER OPENING WITH THE EQUIVALENT VENT AREA SHALL BE - GAS, PROPANE OR OIL WATER HEATER UITH MINIMUM EF OF 0.91 ®a EQUIPMENT NOT EXCEEDING A TOTAL FLOOR AREA OF 200 5Q FT. PERMITTED. OR I. VINYL LAP OR HIMINIMUM OPENING AREA: ALL THE EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE -SOLAR WATER HEATING SUPPLEMENTING .4 MINIMUM STANDARD WATER HEATER AL ALUMINUM SIDING APPLIED OVER AWEATHER-RE51571VE Plan SQ. FT. review approval is subject to errors IN A MIN. NET CLEAR OPENING OF 5.1 -SOLAR WATER HEATING WILL PROVIDE A RATED MINIMUM 64vINGS OF 85 THERMS and omissions. TOS BARRIER AS SPECIFIED IN TABLE 81033(1.). EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MIN. 5.0 SQ. FT. OR 2000 KWH ON THE SOLAR RATING AND CERTIFICATION CORPORATION A rovai of construction BASED 2. BRICK VENEER WITH A CLEAR AIRSPACE AS SPECIFIED IN TABLE R103.8.4 pP documents does not authorize 3. OTHER APPROVED VENTED CLADDINGS. MINIMUM OPENING HEIGHT: THE MIN. NET CLEAR OPENINGS HEIGHT SHALL BE 24 INCHES. (SRCC) ANNUAL PERFORMANCE OF 0G-300 CERTIFIED SOLAR WATER HEATING the MIN OPENING WIDTH SHALL violation of any adopted code or ordinance. Receipt 20 INCHES.1/2 WSEC 8402.4 AIR LEAKAGE (MANDATORY) MINIMUM OPENING WIDTH : THE NET CLEAR BE SYSTEMS THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN MAXIMUM SILL HEIGHT: WHERE A WINDOW 15 PROVIDED AS THE EMERGENCY ESCAPE AND OR of approved Field Copy and conditions is acknowledged: WITH SECTIONS RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44' ABOVE THE FLOOR, - ELECTRIC HEAT PUMP WATER HEATER WITH MINIMUM EF OF 2.0 AND MEETING THE ACCORDANCE THE REQUIREMENTS OF OF R402.4.1 THROUGH 8402.4.4. 8402.4.12 TESTING WHERE THE SILL HEIGHT 15 BELOW GRADE, IT SHALL BE PROVIDED WITH HA WINDOW WELL IN STANDARDS OF NEEA'S NORTHERN CLIMATE SPECIFICATIONS FOR HEAT PUMP By: ' THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR ACCORDANCE WITH SEC. R31023. WATER HEATERS. (D LEAKAGE RATE NOT EXCEEDING 5 AIR EXCHANGES PER HOUR SAFETY GLAZING SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS OR AS OTHERWISE TO QUALIFY TO CLAIM THIS CREDIT,THE BUILDING PERMIT DRAWINGS SHALL SPECIFY Date: 7 Z-,/ 0 REQUIRED PER IRC SECTION 8308.4 THE OPTION BEING SELECTED AND SPECIFY THE WATER HEATER EQUIPMENT TYPE 1. GLAZING IN DOORS - SIDE HINGED DOORS, SLIDING GLASS DOORS AND PANELS IN AND THE MINIMUM EQUIPMENT EFFICIENCY AND, FOR SOLAR WATER HEATING CI of TukwilaSLIDING, 4 DOOR ASSEMBLIES PER IRC SECTION 8308.4.1- BIFOLD SYSTEMS, THE CALCULATION OF THE MINIMUM ENERGY SAVINGS. 2. GLAZING ADJACENT TO DOORS - PANELS WITHIN TI -4E 24' OF EITHER SIDE OF THE DOOR IN BUILDING DIVISION CLOSED POSITION PER IRC SECTIONR308.4.2.SEE N WINDOWS - THE PANE 15 LARGER THAN 9 SQ. FT, THE BOTTOM EDGE 16 LESS * � 3. GLAZINGG ILARGER THAN 18' ABOVE THE FLOOR, THE TOP EDGE IS MORE THAN 36' ABOVE THE FLOOR, AND ONE E 1 FOR WSEC CALCULATIONS * OR MORE WALKING SURFACES, ARE WITHIN 36', MEASURED HORIZONTALLY AND IN A STRAIGHT LINE OF THE GLAZING PER IRC SECTION 8308,4.4. AND PER IRC R \ 1EN1j1AT1O�l R 4. GLAZING IN WET NOTES* CODE COMPLIANCEREVIEWED ENCLOSURESSECTIO FENCES*SEE E-1 FOR MEC1-1 5. GLAZING IN WET OR FENCES CONTAINING OR FACING HOT Y r ' `� SURFACES- WALLS, TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS, AND INDOOR OR APPROVED : RECEIVED OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE 15 LESS THAN 60' PRESCRIPTIVE WHOLE HOUSE VENTILATION SYSTEMS TO BE USED: -, MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE PER IRC SECTION ITEM 3: INTERMITTENT WHOLE HOUSE VENTILATION USING A SUPPLY FAN. , µ. 8308.45. ITEM 4: INTERMITTENT WHOLE HOUSE VENTILATION USING A HEAT RECOVERY VENTILATION SYSTEM. APR 1 7 2018 6. GLAZING ADJACENT TO STAIRS AND RAMPS - WHERE THE BOTTOM EXPOSED EDGE 15 ; TY OF TUKWILA APR 1 1201 4... we LESS THAN 36' ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDING BETWEEN FLIGHTS OF STAIRS AND RAMPS PER IRC SECTION R308.4.6. dity of Tukwila 1• GLAZING ADJACENT TO THE BOTTOM STAIR LANDING - WHERE THE GLAZING 15 LESS THAN BUILDING DIVISION 7j eRMIT CENTER LATER 36' ABOVE THE LANDING AND WITHIN A 60' HORIZONTAL ARC LESS THAN 180 DEGREES C C ii FROM THE BOTTOM TREAD NOSING PER IRC SECTION 8308.4.1. FI e l / ' 1 pe . nitfr1515e°4/D 4'a .€ x , s cmcCORRECT PA'',, -� LT`S PLANNING APPROVED ii/ 6 15 No changes can be mada. to these � plans without approval from the Planning Division of DCD I , 5CAL-I : Approved B : L- Date: p 11 � Aga,, ,• ,e t.,e ii u� £ v S „ fi f a r t f r Y , ,n ,,, ✓, as at 1 PROPERTY LINE PROPERTY LINE REVIEWED FOR CODE COMPLIANCE APPROVED REVISION TABLE DESCRIPTION REVISED BY tu A rz w m X z 0 0 0 0 0 0 voca U °C° " \ NJ 0c nATh: �/</ 56 10'0', l7AG� 2 RECEIVED ITV OF TUKW'ILA PERMIT CENTER ENB LEDGE 59' A.F.F I.V1510\ 2&�: existing basement staling as is SBD30 CLOSET BATH CEILING + 88" m z -4 BEDROOM 1 -43"CEILING w + 90 EXISTING SAUNA LAUNDRY ROOM CEILING + 90• CLOSET HALLWAY CEILING + 90• FAMILY ROOM CEILING + 90' UTILITY ROOM CEILING + 90" OFFICE CEILING + 90' LANDING BASEMENT FLOOR PLAN SCOPE OF WORK: NO CHANGES TO EXISTING BASEMENT SQ. FT. TOTAL 1205 PLAN KEY EXISTING WALLS TO REMAIN EXISTING DOOR REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION N 00 0 VC VC 0 5 5C 110" / PAGE 4 RECEIVED CITY OF TUKWILA PERMIT LEGEND SYMBOL QTY DESCRIPTION 1 DRYEHR WHITEWASMACHINEING WA/DRY O ' WALK IN SHOWER WHITE 1 LAVATORY LAV GROAN 2.5 SONES 80 FM BRUSHED NICKEL EXHAUST FAN AND IGHT WC 6 -CAN LIGHT INCANDESCENT WATER CLOSET TOILET -WHITE O1 8 ELECTRIC WATER HEATER LEGEND SYMBOL QTY DESCRIPTION to Q Lu S) 5 at cz 1 3TIGHT WALL MOUNTED VANITY LIGHT BRUSHED NICKEL INCANDESCENT 13 .2 GROAN 2.5 SONES 80 FM BRUSHED NICKEL EXHAUST FAN AND IGHT Z 6 -CAN LIGHT INCANDESCENT 14N1' El /L"'J\INCANDESCENT 0 8 IN FLUSH MOUNT LIGHT 1 ELECTRICAL PANEL EP SD CM 1 COMBO SMOKE DETECTOR/ CARBON MONOXIDE DETECTOR SD 5 SMOKE DETECTOR Fn/1510N 4; smoke ole-,ec�,or5 and carbon monoxide labeleci on plan REVIEWED FOR CODE COMPLIANCE APPROVED APR 1'7 2018 City of Tukwila BUILDING DIVISION N N 0 ctS \/ 0 REVISION TABLE z 0 1-10 0 to w to Q Lu S) 5 at cz w 0 rz w rn X D z 0 VS0 0 0 0 0 \\ \\ v� O v N 0 PAM: 5CAL 110 / PAG; 4 RECEIVED CITY OF TUKWILA