Loading...
HomeMy WebLinkAboutPermit D17-0334 - VIETNAMESE MARTYRS CHURCH - CARGO CONTAINERCHURCH OF THE VIETNAMESE MARTYRS 6841 S 180T" ST EXPIRED 07/11/18 D17-0334 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3623049087 Permit Number: 6841 S 180TH ST Issue Date: Permit Expires On: • CHURCH OF THE VIETNAMESE MARTYRS D17-0334 1/12/2018 7/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ARCHDIOCESE OF SEATTLE 710 9TH AVE C/O ROY ANNIE, SEATTLE, WA, 98104 DANIEL NGUYEN 1300 S 359 ST , FEDERAL WAY, WA, 98003 AFFIDAVIT - KIEN NGUYEN N/A - LESS THAN $5,000 //1 Phone: (206) 369-1061 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALLATION OF A 8 FT X 40 FT CARGO CONTAINER AS A COOKING SHELTER FOR THE ANNUAL FUNDRAISER. Project Valuation: $1,500.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $197.60 Occupancy per IBC: U Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm, Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit. Center Authorized Signature: Date: iZ S/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a, • ree to the conditions attached to this permit. Signature: Print Name: Date: (�I' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Maintain fire extinguisher coverage throughout. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL CITY OF TUKW1..A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1)11 O332 -f Project No. Date Application Accepted: � € ( 7 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: -1*�Lt1;1A11 Suite Number: Floor: Tenant Name: V 1 E-7 t .I4LI Ar ')1g TAP i —I- New Tenant: ❑ Yes Ed. No PROPERTY OWNER Name: - i� ,r ! rul y tom[ Name: .Agawc_ _ 4i+l Address: Phone: oce,,,)7 - 7.4 - S - 3 S city: -.� i Tb- Sf r4- zip: tb t c) t CONTACT PERSON - person receiving all project communication Name: - i� ,r ! rul y tom[ City: State: Zip: Address: dC)t 4i+l 7 ; ' -7T• Phone: oce,,,)7 - 7.4 - S - 3 S City• i- .- t te: w k t/�i q Zi or 'C:0 3 Phone c?t0....„ , ,., 1 Fax: I .kr\1 fE-1, i L1 f' Y-F-INIe l I C-,-NAA-11 ,. C 3lM GENERAL CONTRACTOR INFORMATION Company Name: /� , Architect Name: City: State: Zip: Address: jGj Address: (/ WA- P►3 L1 Phone: oce,,,)7 - 7.4 - S - Email: �LhF ,. P)1ZcD6f-T2‘c vi RRC u % i G C Av. City: State: i Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line\2012 ApplicationsU'ermit Application Revised - 2-7-12.docx Revised: February 2012 bh ARCHITECT OF RECORD Company Name: P�>.vIpiCA< ARC..Mi T , Architect Name: City: State: Zip: Address: jGj City: State: 4p: WA- P►3 L1 Phone: oce,,,)7 - 7.4 - S - Email: �LhF ,. P)1ZcD6f-T2‘c vi RRC u % i G C Av. ENGINEER OF RECORD Name: Company Name: City: State: Zip: Engineer Name: �R (1 --IRC Address; 7 3611 Li._ City :HNI\t 1I --M4 I AG W l�'p. 4254:2, Phone( ax: ao�\ G2.,-Qibci i Email: /1 LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATII .206-431-3670 Valuation of Project (contractor's bid price): $ j SC -)C.-3 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): ire -. f _f. CC -a 7k -N Ktu Will there be new rack storage? ❑ .... Yes [<No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2O12 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2O12 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO, ATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate 0... Highline ❑ ...Valley View 0...Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage 0...Abandon Septic Tank ❑...Curb Cut 0...Pavement Cut 0...Looped Fire Line ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (I) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public 0 57 15 0...Grease Interceptor ❑... Channelization D... Trench Excavation ❑... Utility Undergrounding WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # 0 .. Deduct Water Meter Size " Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water ❑ .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsWennit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES – Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD OWNER ORIZED AGENT: r Signat I i o Date: f le5 117 Print Name: 1\4( , ; }' Q N' �1�F Day Telephone: �` -i'7�, )3 �—nro ( Mailing Address: .1y.....7Gj , 5(31-11- ',T. j . -_ ;RAL_ 1/V A- y 11,1-,-- t.4 `z City / State Zip / H:Wpplications\Forms-Applicaiions On Line \2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $330.76 D17-0334 Address: 6841 S 180TH ST Apn: 3623049087 $197.60 Credit Card Fee $5.76 Credit Card Fee R000.369.908.00.00 0.00 $5.76 DEVELOPMENT $186.33 PERMIT FEE R000.322.100.00.00 0.00 $110.20 PLAN CHECK FEE R000.345.830.00.00 0.00 $71.63 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $5.51 TECHNOLOGY FEE I R000.322.900.04.00 0.00 $5.51 PG17-0172 Address: 6841 S 180TH ST Apn: 3623049087 $133.16 Credit Card Fee .. -$3.88 Credit Card Fee I R000.369.908.00.00 0.00 i $3.88 PLUMBING $124.31 PERMIT FEE R000.322.100.00.00 0.00$66.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 .;q $24.86 TECHNOLOGY FEE . $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13049 R000.322.900.04.00 0.00 $4.97 $330.76 Date Paid: Monday, December 18, 2017 Paid By: TRUNG NGUYEN Pay Method: CREDIT CARD 02335G Printed: Monday, December 18, 2017 2:57 PM 1 of 1 CSYSTEM$ BRODERICK ARCHITECTS 11/6/17 Attn: Plans Examiner Tukwila Building Division 6300 Southcenter Blvd., Suite #100 Tukwila, WA 98188 RE: Project #: Project Name: Special Permission — Director: Decision Criteria Church of the Vietnamese Martyrs — Cargo Container 6801 S 180th Street, Tukwila WA REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 7 2011 City of Tukwila BUILDING 11V.1S&0. The Vietnamese Martyrs Catholic Parish is applying for permission to temporarily place a cargo container on the south end of their property for the fourth consecutive year. The container will be 40' x 8', and meet all applicable criteria, as outlined below. The cargo container will occupy (3) existing parking stalls. Currently the Parish has a parking requirement of 238 stalls, with 241 provided on site;. The three stall deficit will bring the total provided down to 238, which meets the required quantity. The cargo container will only be on site temporarily. It will be used for a festival from January 25th thru February 17th, then will be removed from the site. While it is on site, the cargo container will be screened by potted plants (thujaoccidentalis — 5' specimens). The cargo container will also be painted white to match the adjacent building. See attached site plan for details. Please see our responses to specific review requirements listed below. Review Criteria: 1. Only two cargo containers will be allowed per lot, maximum length of 40 feet. One 40' container is proposed. 2. The container is located to minimize the visual impact to adjacent properties, parks, trails and rights-of-way as determined by the Director. The container is placed near the southwest corner of the building adjacent to the loading dock area. The container will be painted to match the building color to help disguise it from the neighboring dike walkway. 3. The cargo container is sufficiently screened from adjacent properties, parks, trails and rights-of- way, ights-ofway, as determined by the Director. Screening may be a combination of solid fencing, landscaping, or the placement of the cargo containers behind, between or within buildings.The cargo container will be screened by potted plants to help disguise it. The plants will be located to hide the container as well as possible, while maintaining access to the (3) doors on the container. The screening will be 5' tall thujaoccidentalis (smargad) plants in large containers — placed approximately 20" on center around the perimeter of the container as shown in the attached site plan. 4. If located adjacent to a building, the cargo container must be painted to match the building's color. The container will be painted to match the building. ;RECEIVED 5. Cargo containers may not occupy any required off-street parking spaces.The� TUKWILA bro33 DEC 182017 PERMIT CENTER temporarily occupying (3) offsite parking spaces, but not required parking spaces. The container has a limited duration on site, and will be removed after the festival in February 2018. 6. Cargo containers shall meet all setback requirements for the zone. The container meets all setback requirements. 7. Outdoor cargo containers may not be refrigerated.The container is not refrigerated. 8. Outdoor cargo containers may not be stacked.The container will not be stacked. We believe the proposed cargo container location and placement meets all City of Tukwila requirements. If you have any questions or concerns, please contact us at your convenience. Sincerely, Kevin J. Broderick, AIA Broderick Architects 6/1/2018 City of Tukwila Department of Community Development DANIEL NGUYEN 1300 S 359 ST FEDERAL WAY, WA 98003 RE: Permit No. D17-0334 CHURCH OF THE VIETNAMESE MARTYRS 6841 S 180 ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/11/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates anew 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/11/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, `ace'e Permit Technician File No: D17-0334 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 State of Washington Department of Agriculture P.O. BOX 42560 Olympia, WA 98504-2560 In accordance with the provisions of Chapter 69.07 RCW Food Processing Plant License License Number: 20160 Tuyen Pham Vietnamese Martyrs Parish 6841 S 180th St Tukwila , WA 98188 Is Licensed to Produce the Following Product(s): BOILED RICE CAKES REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 7 2017 City of Tukwila BUILDING DI IISIO; br7Q33q Valid from 7/1/2017 through 6/30/2018 RECEIVED CITY OF TUKWILA DEC 18 2017 PERMIT CENTER This License is non -transferable with respect to persons and/or locations. This License is also subject to revocation or suspension for violations of state laws or regulations. 1.L,. GROSS :S'IRUCI"URAL ENGINEERS Vietnamese Martyrs Cargo Container Tukwila, WA Structural Uplift Analysis Calculations for Permit Submittal REVIEWED FOR CODE COMPLIANCE APPROVED DEC 27 2017 City of Tukwila 1 V7Q33LI November 3, 2017 RECEIVED CITY OF TUKWILA DEC 18 2017 PERMIT CENTER 23914 56th Ave W. — Suite # 200 Mountlake Terrace, WA 98043 Ph. (206) 623-0769 • (425) 640-7333 1 of 1 s Summary Report http://ehpl-earthquake.cr.usgs.gov/designmaps/us/summary.php?te... IusGS Design Maps Summary Report User -Specified Input Report Title Vietnamese Martyrs Frl January 16, 2015 20:29:39 UTC Building Code Reference Document • 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44112°N, 122.21573°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III I-7Smi I 5000m8 '11 EastRenton Highlands': c: IARBOR 0B _East Hill • 4?' '0 mapgUast ' USGS-Provided Output Ss = 1.403 g Sl = 0.523 g -Kent SMS = 1.403 g SML = 0.784 g lvi Sss = 0.936 g SD1 = 0.523 g ® MapQuest For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1.65 1.50 1.35 1.20 1.05 0.90 0.75 0.60 0.45 0.30 0.15 0.00 0.00 0.20 0.40 0.0 0.80 1.00 1.20 1.40 1.60 1.90 Period, T (sec) 2.00 1.10 1.00 0.90 0.80 0.70 01 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0.00 Design Response Spectrum 0.20 0.40 0.0 0.80 1.00 1.20 1.40 1.60 1.90 Period, T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool Is not a substitute for technical subject -matter knowledge. 1 /14/1(11G 11.111 D11d I.L. Gros Structural Engineers 23914 56th Ave West Project Title: Vietnamese Martyrs Cargo Container Engineer: VM Project ID: Project Descr: Uplift Analysis on Temporary Cargo Container Printed: 17 JAN 2015, 2:40PM ASCE Seismic Base Shear File = v:1A5AQ92-E\V2OPHI-DICSIQ59-21CSIQ59-2.EC6 ENERCALC, INC. 1983-2015, Build:6.15.1.6, Ver:6.15.1.6 • KW46002858174. • Cargo Container base Shear Risk Category Calculations per ASCE 7-10 Risk Category of Building or Other Structure : "II" : All Buildings and other structures except those listed as Category I, III, and IV Seismic Importance Factor = USER DEFINED Ground Motion 1 ASCE 7-l0, Page 2, Table 1.5-1 ASCE 7-10, Page 5, Table 1.5-2 ASCE 7-10 11.4.1 Max. Ground Motions, 5% Damping : SS 1 • 1.403 g, 0.2 sec response • 0.5230 g, 1.0 sec response Site Class, Site Coeff. and Design Category Site Classification "D" : Shear Wave Velocity 600 to 1,200 ft/sec Site Coefficients Fa & Fv (using straight-line interpolation from table values) Maximum Considered Earthquake Acceleration SMS = Fa * Ss SM1=Fv*S1 Design Spectral Acceleration Seismic Design Category Resisting System Basic Seismic Force Resisting System ... Response Modification Coefficient " R " System Overstrength Factor " Wo " Deflection Amplification Factor " Cd " Fa Fv SDS SMS 213 S Di S Mi 2/3 = D = 1.00 = 1.50 • 1.403 = 0.785 = 0.935 = 0.523 • D ASCE 7-10 Table 20.3-1 ASCE 7-10 Table 11.4-1 & 17.4-2 ASCE 7-10 Eq. 11.4-1 ASCE 7-10 Eq. 11.4-2 ASCE 7-10 Eq. 11.4-3 ASCE 7-10 Eq. 11.4-4 ASCE 7-10 Table 11.6.1 & -2 ASCE 7-10 Table 12.2-1 Bearing Wall Systems Light -framed walls with shear panels of all other materials 2.00 Building height Limits : = 2.00 Category "A & B" Limit: = 2.00 Category "C" Limit: Category "D" Limit: Category "E" Limit: Category "F" Limit: NOTE! See ASCE 7-10 for all applicable footnotes. Redundancy Factor No Limit No Limit Limit = 35 Not Permitted Not Permitted ASCE 7-10 Section 12.3.4 Seismic Design Category of D, E, or F therefore Redundancy Factor " p " = 1.3 Lateral Force Procedure ASCE 7-10 Section 12.8.2 Equivalent Lateral Force Procedure The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-1012.8 Determine Building Period Structure Type for Building Period Calculation : " Ct " value = 0.020 " x " value = 0.75 " Ta " Approximate fundemental period using Eq. 12.8-7 : "TL" : Long -period transition period per ASCE 7-10 Maps 22-12 -> 22-16 All Other Structural Systems " hn " : Height from base to highest level = " Cs " Response Coefficient Ta=Ct*(hn^x) = 8.50 ft 0.100 sec 6.000 sec Use ASCE 12.8-) Building Period " Ta " Calculated from Approximate Method selected = 0.100 sec ASCE 7-10 Section 12.8.1.1 S DS: Short Period Design Spectral Response " R " : Response Modification Factor " I " : Seismic Importance Factor = 0.935 From Eq. 12.8-2, Preliminary Cs = 2.00 From Eq. 12.8-3 & 12.8-4 , Cs need not exceed = 1 From Eq. 12.8-5 & 12.8-6, Cs not be less than User has selected ASCE 12.8.1.3: Regular structure, Less than 5 Stories and with T «= 0.5 sec, SO Ss <= 1.5 for Cs calculation Cs : Seismic Response Coefficient = = 0.468 2.627 0.041 = 0.4677 y.L. Grogs Structural Engineers 23914 56th Ave West Project Title: Vietnamese Martyrs Cargo Container Engineer: VM Project ID: Project Descr: Uplift Analysis on Temporary Cargo Container Printed: 17 JAN 2015, 2:40PM ASCE Seismic Base Shear Lic. # : KW -06002858 j Seismic Base Shear Cs = 0.4677 from 12.8.1.1 File = v:1A5A092-E1V2OPHI-DICSIQ59-21CS1059-2.EC6 ENERCALC, INC. 1983-2015, Build:6.15.1.6, Ver:6.15.1.6 Licensee : I.L. GROSS STRUCTURAL ENGINEERS ASCE 7-10 Section 12.8.1 Vertical Distribution of Seismic Forces " k " : hx exponent based on Ta = 1.00 Table of building Weights by Floor Level... W ( see Sum Wi below) _ Seismic Base Shear V = Cs * W = 10.00 k 4.68 k ASCE 7-10 Section 12.8.3 Level # Wi : Weight Hi : Height (Wi * Hi) Ak Cvx Fx=Cvx * V Sum Story Shear Sum Story Moment 1 Sum Wi= 10.00 10.00 k 8.50 Sum Wi * Hi = r Diaphragm Forces : Seismic Design Categy "B" to "F" i Level # Wi Fi 85.00 1.0000 85.00 k -ft 4.68 Total Base Shear = 4.68 4.68 k Base Moment = 0.00 39.8 k -ft ASCE 7-10 12.10.1.1 Sum Fi Sum Wi Fpx 1 10.00 4.68 4.68 10.00 Wpx Weight at level of diaphragm and other structure elements attached to it. Fi Design Lateral Force applied at the level. Sum Fi Sum of "Lat. Force" of current level plus all levels above MIN Req'd Force @ Level 0.20 * SDS * 1 * Wpx MAX Req'd Force @ Level 0.40 * SDs * 1 * Wpx Fpx : Design Force @ Level Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level 3.74 LL. Gros -Structural Engineers 23914 56th Ave West Project Title: Vietnamese Martyrs Cargo Container Engineer: VM Project ID: Project Descr: Uplift Analysis on Temporary Cargo Container Printed: 3 NOV 2017, 2:36PM IBC 2015 1609.6 Alternate AII-Heights Wind Lic. # : KW -06002858 icense File = V:\AUGZ08-X1V2OPHI-D\CSIQ59-21CSIQ59-2.EC6 ENERCALC, INC. 1983-2017, Build:10.17.8.3, Ver:10.17.8.3 e • - 1 I L Description : Vietnamese Martyrs Wind Force on Cargo Container Analytical Values Calculations per IBC 2015 1609.6 User verified these IBC 2015 AII-Heights Wind Method Limitations : 1609.6.1 (1) : 1609.6.1 (2) : 1609.6.1 (3) : 1609.6.1 (4) : 1609.6.1 (5) : 1609.6.4.1 : Total Height <= 75 ft with (Height / Least Width) <= 4 -or- Fundamental frequency >= 1 hertz Not sensitive to dynamic effects Site not affected by channeling/buffeting from upwind items Simple diaphragm building per ASCE 7-05 Sec 26.2 Aware of ASCE 7 provisions for open buildings, multispan gable roofs, stepped roofs, sawtooth roofs, domed roofs, roofs with slopes > 45 deg, solid free standing walls & signs. Aware of need to check torsion per ASCE 7 Fig. 27.4-8 MWFRS Table per IBC 2015 1609.6.2, Section 1 WINDWARD WALLS & PARAPETS Analytical Values... Exposure Category, ASCE 7-10 Sect 26.7.3 Mean Roof Height Topographic Factor per ASCE 7-10 Sec 26.8.2 K1 = 0.250 K2 = 1.0 Force Kzt to 1.0 per ASCE 7-10 26.8.2 Topographic Factor Kzt = (1+K1*K2*K3)^2 = V : Basic Wind Speed per ASCE 7-10 26.5.1 K3 = Exposure B 8.50 ft 1.0 Yes 1.000 115.0 mph Design Pressure P = 0.00256 VA2 K CK netz zt WALLS PARAPETS p-sf Partially Enclosed +Internal -Internal Kz based on ibc 2015 1609.6.4.2 Item 1 Height Kz +Internal -Internal Enclosed 0-15' 20' 25' 30' 40' 50' 60 ' 70 ' 80' 90' 100' LEEWARD & SIDEWALLS 0.570 8.32 14.13 2.13 20.32 0.620 9.05 15.37 2.32 22.10 0.660 9.64 16.36 2.46 23.53 0.700 10.22 17.35 2.61 24.95 0.760 11.09 18.84 2.84 27.09 0.810 11.82 20.07 3.02. 28.87 0.850 12.41 21.07 3.17 30.30 0.890 12.99 22.06 3.32 31.73 0.930 13.58 23.05 3.47 33.15 0.960 14.01 23.79 3.59 34.22 0.990 14.45 24.54 3.70 35.29 Enclosed Partially Enclosed +Internal -Internal +Internal -Internal Enclosed Partially Enclosed 24.77 26.94 28.68 30.42 33.03 35.20 36.94 38.68 40.41 41.72 43.02 24.77 26.94 28.68 30.42 33.03 35.20 36.94 38.68 40.41 41.72 43.02 Kz based on IBC 2015 1609.6.4.2 Item 2 Leeward Wall Side Wall Parapet Wall : Leeward 0.570 -9.87 -12.77 Both Directions -4.06 -16.06 -6.77 -18.77 -16.45 Both Directions 2.13 0.77 -16.45 I.L. GrogsStructural Engineers 23914 56th Ave West Project Title: Vietnamese Martyrs Cargo Container Engineer: VM Project ID: Project Descr: Uplift Analysis on Temporary Cargo Container Printed: 3 NOV 2017, 2:36PM IBC 2015 1609.6 Alternate AII-Heights Wind Lic. # : KW -06002858 Description : Vietnamese Martyrs Wind Force on Cargo Container MWFRS per IBC 2015 -Table 1609.6.2 Section 1 Kz per IBC 2015 1609.6.4.2 Item 2 = 0.570 WIND PERPENDICULAR TO RIDGE File = V:IAUGZ08-X1V2OPHI-DICSIQ59-21CSIQ59-2.EC6 ENERCALC, INC. 1983-2017, Build:10.17.8.3, Ver..10.17.8.3 Licensee : I.L. GROSS STRUCTURAL ENGINEERS Design Pressure P = 0.00256 VA2 Kz net Kzt psf Leeward Roof or Flat Roof Windward Roof Slopes Enclosed Partially Enclosed +Internal -Internal +Internal -Internal -12.77 -6.77 -18.77 -0.77 Slope < 2:12 (10 deg) Slope < 4:12 (18 deg) Slope < 5:12 (23 deg) Slope < 6:12 (27 deg) Slope < 7:12 (30 deg) Slope < 9:12 (37 deg) Slope < 12:12 (45 deg) WIND PARALLEL TO RIDGE Condition 1 Condition 2 Condition 1 Condition 2 Condition 1 Condition 2 Condition 1 Condition 2 Condition 1 Condition 2 Condition 1 Condition 2 -21.09 -15.29 -27.29 -9.10 -5.42 0.39 -11.61 6.58 -14.13 -8.13 -20.13 -2.13 -0.97 4.84 -7.16 11.03 -11.22 -5.42 -17.42 0.77 0.58 6.58 -5.61 12.58 -9.10 -3.10 -15.09 2.90 1.16 7.16 -4.84 13.16 -7.16 -1.16 -13.16 -5.03 1.35 7.16 -4.84 13.35 -5.22 0.77 -11.22 6.77 2.71 8.51 -3.48 14.71 2.71 8.51 -3.48 14.71 All slopes including Flat Roofs -21.09 -15.29 -27.29 -9.10 Roof & Overhang Components & Cladding per IBC 2015 Table .1609.6.2, Section 2 & 3 Design Pressure P = 0.00256 VA2 K CK netz zt Description Continuity Item Type Eff. Area Kz ft^2 Enclosed Partially Enclosed No Discontinuity Tall Flat top roof where h>60 ft 10.00 0.570 + : 0.00 0.00 Work Parapet Components & Cladding per IBC 2015 Table 1609.6.2, Section 4 & 5 Description Continuity Item Type - : -25.93 -32.12 Design Pressure P = 0.00256 VA2 K net Kzt Kz Z, Ht. Above Ground Eff. Area Enclosed Partially Level, ft ft^2Enclosed No Discontinuity Wall Elements, h<=60 ft 25 10.00 0.66 + : 22.41 29.58 -24.42 -31.37 Container Weight = 10000# per Aztec Container 40 'twat: viith 2 Ra -Up ?mss 40'x8.5'x8' 40' X 8' CARGO CONTAINER TEMPORARY LOCATION OCCUPIES (5) PARKING STALLS - NONE OF WHICH ARE REQUIRED. SCREENED BY (20) POTTED PLANTS: 5' THUJA OCCIDENTALIS (SMARAGD) IN POTS. CARGO CONTAINER TO BE WHITE IN COLOR TO MATCH BUILDING WALL COLOR. Veq=4.68x1.3x0.7=4.3k. eEF��NG Uplift EQ: 0.6-.014Sds x D = 0.6-0.14(.936) = 0.47D EXISTING TRUCK LOADING AREA - Wind = 22 psf. Vwind transverse = 22 psf x 40 x 8.5 = 7.480 x 0.6 = 4.5k Therefore Wind Governs N AAJiMp = 4/15K(ASD) ‘0J =I°14 GZ LJP�� T= l (2. moo. -trey l **2- �i1 AIZY` L S I� 890$V621 s ili, 7-4 )e -Pf7 (3J SS Sol' Rom_r 16594( 64, cvR 46."_, lO6. - 01►5 7e 0,5 3f3,3 � /lues py,25-K-.7 - 7=-6- = ilMe1-10 - 1' 7-b' -5 17E(c)# PSsv,H.6. ;14(6, 941 -, RAD 1.ot4D ¢ /064 -- 04/ Qp s, cs541=1/$0# (3) V11/2464- S r (`f/ Go41466, L5 r 1158 #fJ d€/Lfc- = Sgt96� ,11,141= Dr3 x 1:57 1(90 y6V2 7 .i/S - /,03 F,S,.... ISD (l) &Q,2. ?'1 ? /S,y6 p�✓� (t)5( w4 aai-i-s 0111 -rbk- 1 4 -tap sg-romuy vel -IIT /4000 = #9446 097- /yscv= /,;p DK I.L. GROSS B RDCIIIRAt.BNCHlSEIIB VM Gft0�K SHEET TITLE V 167/`(4M �S 4414 --TY /1',S 414Thiti PROJECT M PbAc SCALE v4, DESIGNED BY CLIENT CHECKED _/S DATE /0e/ SHEET 23914 56th Avenue West - Suite 200 Mountlake Terrace, Washington 98043 (Ph) 206.623.0769 or 425.640.7333 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0334 DATE: 12/18/17 PROJECT NAME: CHURCH OF THE VIETNAMESE MARTYRS SITE ADDRESS:. 6841 S 180 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: R-1 NIU Building Division Public Works D7 A -/A AVG P)-7 r7 " PO 46iJ;L1 Fire Prevention 141Planning Division Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 12/19/17 Structural Review Required REVIEWER'S INITIALS: DATE: C APPROVALS OR CORRECTIONS: DUE DATE: 01/16/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: ,Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 CITY OF TUKWVILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665. E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: IM07297 STATE OF WASHINGTON) ) ss. COUNTY OF KING ) fr'ti t"Ie1i4't'i_2'J, states as follows: [please priy{t na 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit..I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirem nt of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction er's Agentj Signed and sworn to before me this 1()- day of Janry ,20j l NOTARY PUBLIC in ad for State of Washington Residing at Name as commissioned: My commission expires: zwh IIS Wile"y 17IOA \bo 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; to. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid' electrical, contractor's license under chapter 19:28-RCW that eitploys,a certified journeyman electrician, -a certified residential}specialty electrician, or an electricalrtra nee meeting''the '- requirements of chapter 19.28 RCW to perform plumbing work that is incidentally; .directly, and immediately appropriate to the like -in-kind replacement of abhousehold appliance or other small househo1 I tllization;equipment o - that requires limited electric pwerd' limited waste and/or water connections. An,electrical trainee must be supervised by a certified electrician ''wlile performing plumbing work. Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. • writing. Copyright 0 Thursday, February 4, 2016 by Broderick Architects, pllc s 5 s PARCEL # 3623049094 EXISTING 5' CHAIN LINK FENCE PSpNPk-19P'��NG "TRUE POINT OF BEGINNING" & "POINT A" Z• 00 ¢> ac 111LU11 0� 00 ZW Z� wDZ°L CZ L)w 48'-0" EXISTING ASPHALT PARKING, TYP. PARCEL # 3623049017 1 ■ 4 5 • LL®■■• ■ - - - -�' Q" , 19'-r" - FRONT SETS EXISTING LAWN EXISTIN • • • GREEN RIVER PLANNING APPROVE_ : No changes can be madeto these plans without approval from the Planning Division of DCD Approved Dy:,- ,goal Date' • `\ • • EXISTING CHURCH 40' X 8' CARGO CONTAINER TEMPORARY LOCATION OCCUPIES (5) PARKING STALLS - NONE OF WHICH ARE REQUIRED. SCREENED BY (20) POTTED PLANTS: 5' THUJA OCCIDENTALIS (SMARAGD) IN POTS. CARGO CONTAINER TO BE WHITE IN COLOR TO MATCH BUILDING WALL COLOR. SHORELINE URBAN CONSERVANCY ENVIRONMENT SETBACK - 125' FROM OHWM @ NON -RESTORED LEVY AREA EXISTING CONCRETE PATIO EXISTING CHAIN LINK FENCE EXISTING LAWN OE OF SLOP SEPARATE PERMIT REQUIRED FOR: I Mechanical Eellectrioal [Plumbing 1 (Gas Piping LCity of Tu yll,n1;`.NG ARCHITECTURAL SITE PLAN 1" = 30' ORDINARY HIGH WATER MARK @ 15' WO 04$ ftimow, as 00 REVISIONS change -s sh it hn made to the scope of wort- x,,ithoa; prior approval of B,iiding. Division. : !.zicris will require a new plan submittal anti may in,;uda additional plan review fees. PROJECT NOTES PROJECT ADDRESS: 6801 5. 180TH STREET TUKWILA, WA 98188 PROJECT DESCRIPTION: OWNER: ARCHITECT: STRUCTURAL ENGINEER: PLACEMENT OF (1) CARGO CONTAINER ON SITE AT SOUTH PARKING LOT. CONTAINER TO MATCH BUILDING WALL COLOR. SCREENING AROUND CARGO CONTAINER TO BE 5 -GALLON POTTED PLANTS A MINIMUM OF 5' TALL. CORP. OF CATHOLIC ARCHBISHOP OF SEATTLE / ED FOSTER 719 9TH AVE SEATTLE, WA 98104 206.382.4560 BRODERICK ARCHITECTS 55 5. ATLANTIC STREET, SUITE 301 SEATTLE, WA 98134 206.682.7525 206.682.7529 (F) CONTACT: KEVIN BRODERICK kevin@broderIckarchitects.com I.L. GROSS STRUCTURAL ENGINEERS 23914 56TH AVE WEST, SUITE 200 MOUNTLAKE TERRACE, WA 98043 206.623.0769 CONTACT: IRA GROSS Ira@Ilgross.com LEGAL DESCRIPTION: SEG AT NW COR SEC 36 TH 5 01-19-01 W 1320.01 FT TO NW COR OF GL 4TH 5 88-04-53 E 381.81 FT TH 5 01-55-07 W 341 FT TH N 88-04-53 W 50 FT TO TPOB TH 5 88-04-53 E 426 FT M/L TO TOP OF LEFT BANK OF GREEN RIVER TH 5 07-00 E 106 FT TH 5 01-06 W 104 FT TH 5 09-12 W 106 FT TH 5 26-49 W 102 FT TH 5 47-21 W 103 FT TH 5 60-15 W 40 FT TH 5 74-35 W 60 FT TH W 106 FT TH N 67-30 W 107 FT TH N 26-19 W 104 FT TH N 20-22 W103 FT TH N 21-54 W105 FT TH N 32-38 W116 FT TH N 44-04 W 35 FT M/L TAP FR WH TPOB BEARS 5 70-20-07 W TH N 70-20-07 E 220 FT M/L TO TPOB TGW ESMTS TGW UND INT IN PRIVATE RD ADJ FOR ASSESSMENT PURPOSES PARCEL NUMBER: 3623049087 PLANNING NOTES ZONING: LOT AREA: LOT COVERAGE: PARKING: TUC 251,300 5F (5.77 ACRES) 62,250 SF (25%) BUILDING TOTAL EXISTING: 241 STALLS PROPOSED: 238 STALLS REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 7 2017 AT j City of Tukwila BUILDIP .DIVISIOM REQUIRED: ASSEMBLY AREA: (1 PER 4 FIXED SEATS) NAVE: 733 SEATS/ 4 =184 STALLS BUSINESS: (3 PER EACH 1000 5F OF USEABLE AREA) OFFICES: 4-242 5F / 333.33 =13 STALLS EDUCATION: (1.5 PER EA. STAFF, 27 CLASSES = 27 STAFF) CLASSROOMS: 1.5 X 27 = 41 TOTAL REQUIRED PARKING: 184+13+41 = 238 STALLS BIKE PARKING: 8 STALLS MINIMUM FILE COPY Permit No. 11- 0 33 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field o . conditions is acknowledged: City of Tukwila BUILDING DIVISION LEGEND: PROPERTY LINE EASEMENTS EXISTING FENCE 8" CONCRETE CURB SETBACK ORDINARY HIGH WATER MARK TOE OF SLOPE EXISTING LANDSCAPE AREAS EXISTING BUILDING DIRECTION OF TRAVEL EXISTING HYDRANT EXISTING TREES (TO REMAIN) RECEIVED DEC 18 2017 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA DEC 18 2017 PERMIT CENTER 00 00 00 c) J W CY V) 0 00 V5 r 00O 1 11 14.012 CARGO CONTAINER PERMff.pin O 0. 0 N 206.682.7525 I E. DESCRIPTION d z 11/6/2017 SITE PLAN br1O33 ci