Loading...
HomeMy WebLinkAboutPermit D17-0085 - GATEWAY NORTH BUILDING 5 - REROOFGATEWAY NORTH BUILDING 5 3415 S 116 ST D17-0085 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 1023049043 Permit Number: D17-0085 3415 S 116TH ST BLDG 5 Project Name: GATEWAY NORTH BUILDING 5 Issue Date: 4/24/2017 Permit Expires On: 10/21/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 JOE DICARLO 13105 HOUSTON RD E , SUMNER, WA, 98390 WAYNE'S ROOFING INC 13105 HOUSTON RD, SUMNER, WA, 98390-9208 Phone: (253) 750-3223 Phone: (253) 863-4455 WAYNESR205Q5 Expiration Date: 5/2/2017 CBRE INC 20415 72ND AVE S #210 C/0 STOCKBRIDGE CAPITAL GP, KENT, WA, 98032 DESCRIPTION OF WORK: REMOVE AND DISPOSE OF EXISTING BUR ROOFING ASSEMBLY. INSTALL NEW R-38 INSULATION ASSEMBLY UNDER NEW MECHANICALLY ATTACHED WHITE PVC SINGLE PLY UL CLASS A FIRE RATED MEMBRANE ROOF ASSEMBLY. 20 YR NDL ,ANUFACTURERS LABOR AND MATERIAL WARRANTY. RAISE EXISTING ROOFTOP CURBS TO ACCOMODATE INSULATION THICKNESS. Project Valuation: $314,720.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $5,794.49 Occupancy per IBC: B Water District: TUKWILA Sewer District: VALLEY VIEW L Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 11—,14—( -, I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit ree to th- nditions attached to this permit. Signature: Print Name: � 1 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0612 EXT ROOFING INSUL 0103 PRE-REROOF 0401 ROOF SHEATHING CITY OF TUKWILA Community Development Department Public Works Department Permit. Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: )4 I 1 ' 17 Date Application Expires: 0," f I "f7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3415 South 116th Street Tukwila, WA Tenant Name: Gateway North Building 5 PROPERTY OWNER Name: RREEF L1 Corp. MMMM7 Washington Address: 20415 72nd Ave South City: Kent State: WA Zip: 90803 CONTACT PERSON — person receiving all project communication Name: Joe DiCarlo Address: 13105 Houston Rd E City: Sumner State: WA Zip: 98390 Phone: (253) 750-3223 Fax: (253) 863-8311 Email: joe@waynesroofing.com GENERAL CONTRACTOR INFORMATION Company Name: Wayne's Roofing, Inc Address: 13105 Houston Rd E City: Sumner State: WA Zip: 98390 Phone: (253) 750-3223 Fax: (253) 863-8311 Contr Reg No.: WAYNESR*205Q5 Exp Date: 05/02/2017 Tukwila Business License No.: BUS -0994409 H:\Applications\Fora s -Applications On Line12011 Applications\Permit Application Revised - 8-9-1 I.doc, Revised: August 2011 bh King Co Assessor's Tax No.: 20-3940658 Suite Number: Floor: New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: Westcoast Roof Consultant Architect Name: Mark Curry Address: 245 Fischer Ave Suite B3 City: Costa Mesa State: CA Zip: 92629 Phone: (714) 545-7663 Fax: (714) 545-7664 Email: mcurry@westcoastrc.net ENGINEER OF RECORD Name: C-:5 Company Name: N/A Address:. I5 _ 2T)d l�• , E So s -t- 10 Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: C-:5 Address:. I5 _ 2T)d l�• , E So s -t- 10 City: L'_xr(�'7� State:L,01 Zip:01.0z Page 1 of4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 314,720 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Remove and dispose of existing BUR roofing assembly -- Install new R38 insulation assembly under new mechanically attached white PVC single ply UL Class A Fire rated membrane roof assembly - 20 yr NDL manufactures Labor and Material Warranty Raise existing rooftop curbs to accommodate insulation thickness Total Square Footage of Roof Area -- 35,800 sq ft Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas. in Square Footage Below PLANNING DIVISION: • Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ZI No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9.1 l.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per ' IBC Type of Occupancy per IBC I' Floor . rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered. Deck Uncovered Deck PLANNING DIVISION: • Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ZI No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9.1 l.docx Revised: August 2011 bh Page 2 of 4 1ER PLICAT ',c6 NiOT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI R df AUT OR ZED A T: Signat� '\- L� Date: .Lil/1/./ 7 Print Name: Jule DiCarlo Day Telephone: (253) 606-7797 Mailing Address: 13105 Houston Rd E - Sumner , WA 98390 CityState Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK ;, PAID $5,794.49 D17-0085 Address: 3415 S 116TH ST BLDG 5 Apn: 1023049043 $5,794.49 DEVELOPMENT $5,624.20 PERMIT FEE R000.322.100.00.00 0.00 $3,405.88 PLAN CHECK FEE R000.345.830.00.00 0.00 $2,213.82 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $170.29 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11248 R000.322.900.04.00 0.00 ` $170.29 $5,794.49 Date Paid: Tuesday, April 11, 2017 Paid By: WAYNE'S ROOFING INC Pay Method: CHECK 8658 Printed: Tuesday, April 11, 2017 2:24 PM 1 of 1 CISYSTEMS INSPECTION RECORD Retain a copy with permit pl7 Oc�B` 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: G1-� w Y Negif4 Type of Inspection: SW LANG- FI Address: 341 S' $ , 1/677/ Date Called: SpecialInstructions: `» 5 -Date Wanted: a.m ,/f a -7 p.m.' Requester: Phone No: s3-4,34 -s 7Y 0 Corrections required prior to approval. , pproved per applicable codes. COMMENTS: Z7 - F11/LD) NG- •ft/f-L -. Inspector: Date: /-Z-/7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit 4117-60A--1 KProject: oit. c./%y..A1Yi 4 1u ‹ T p/,e.off Inspection: r (JY Sieh,/ a��ti- Address: Date Called: Special Instructions: Date Wante : - a.m. p.m. Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection.fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INS INSPECTION RECORD Retain a copy with permit ON. NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6pyj +c Type of lns ection: { Eder 1410.4.16 Address: 391V S ilo77A '1.— Date Called: Special Instructions:c-'g�� Date Wanted: a.m. Requester. PhogNo: —e �n ac l` d '7799 Approved per applicable codes. COMMENTS: Corrections required prior to approval. Inspector:4/141 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain"a copy with permit r'1- d06s" PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6/\"ZLc AY ili li r T e'of Inspection: 4�/.Sl r iPAre- Address: 5S— 5 ale 771 S,' Date Called: . Special Instructions: - Date Waned : 3� 17 Ti..- Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0 C4>/✓%17iif Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit tkf—©08 PERMIT NUMBERS CITY OF TUKWILA FIREDEPARTMENT 206-575-4407 Project: . i'"FNCO. Type of Inspection t.2A Address: Suite #: f 3 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ‹Pct. 9r4c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: 'Pre -Fire: Permits: Occupancy Type: Inspector (3 Date: /0/irk) Hrs.: /. o $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Google Earth 214 permit eters Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of appr" Copy and •‘• Ediis acknowledged: City of Tukwila DI 111 With i# t REVISIONS No changes shall be made to the scope of work withoa prior approval of Tukwila Building Division l NOTE: Revisions will require a new plan submittal and may include additional plan review fccs 1000 SEPARATE PL -71'..11T REQUIRED FOR: E mechanical (Iectncal umbing IS Gas Piping Vit! C y of Tukwi!a CODE COMPLIANCE a' 717V APR 2 0 2017 11-4 City of Tukwila BUILDING DIVISION 11-- OOs- A RECEIVED CITY OF TUKWILA APR 112017 PERMIT CENTER Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofino.com 1[Orfelio-- WAYNFiS HOOFING, NC. 6.1 .1 1 11 1 1.' SU1.INER. WA Roofing Submittal Section—Membrane Roofing & Related Insulation April 6, 2017 PROJECT Gateway North - Bldg 5 3415 South 116th Street Tukwila, WA PREPARED FOR CBRE, INC 2nd Ave So, Suite 210 Kent, A 98032 REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 0 2017 City of Tukwila BUILDING DIVISION bnooas RECEIVED CITY OF TUKWILA APR 112011 PERMIT CENTER WRI PROJECT 17-023 SUMNER (253) 863-4455 SEATTLE (206) 575-0078 FAX (253) 863-8311 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofinq.com 11O0l1A(., IN(.. III' III' S)1MNLN WP Gateway North Bldg 5 DRAWINGS ■ System Descriptions 1 PRODUCT DATA 2 ■ Roofing & Accessories Product Data CERTIFICATION 3 ■ UL Listing ■ Sarnafil Approved Applicator Status WARRANTIES ■ Sikaplan Plus Warranty ■ Contractor's Sample Warranty 4 April 18th, 2013 WRI PROJECT 17-023 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com WAYN'Ei;S ROOFING, INC. x -v iL.LVLI 1.1_' SUMNER. WA DRAWINGS 1 1- 6 A 3 rJ if) N N 0 Je, 34. 2016 ROOF SURVEY 0 0 M es N 0 a i3RW BY - CF 8, 0" Insulation Data Bottom Middle Top • • • Notes: MANUFACTURER SARNAFIL SARNAFIL SARNAFIL Cr - Perimeter & Corner Areas TYPE SARNATHERM POLYISO SARNATHERM POLYISO SARNATHERM ROOF BOARD -H • • • are Determined in Accordance with ASCE-7: THICKNESS - 3.1 INCH 3.1 INCH 1/2" Field Layout 1/10 Least Plan Width or 4/10 Roof Height but not R-VALUE (Total R38) 18.0 18.0 2.5 6 Fast/BD 8'-0" Less than 4 Ft NO. OF LAYERS SINGLE SINGLE SINGLE Where Parapet exceeds 36" ATTACHMENT LOOSE LOOSE MECHANICAL p Corner Fastener is not needed FASTENER TYPE N/A N/A SARNAFASTENER XP V • • • • • FASTENER LENGTH N/A N/A 8 INCH Perimeter Layout NOTE: BOARD SIZE 4X8 4X8 4X8 10 Fast/BD Actual Fastening Pattern To Be Determined following FIELD FASrG N/A N/A 6 8' - 0" Fastening Pull Test PERIMETER FAST'G N/A N/A 10 • • • • • •• This is the MINIMUM PATTERN CORNER FAST'G N/A N/A 16 • • • • FM REQ(PATTERN ONLY) N/A N/A N/A • • •• Corner Layout 16 Fast/BD INSULATION FASTENING PATTERN SikaPlan 60 mil Roof •i -, � Membrane (Heat Welded) (White) III Induction Welded RhinoBond Assembly ///// ////// 1/2" Sarnatherm Roof Board-H :.:: ; .:. ••: _ : (Mechanically Attached) 3.1" Sarnatherm 20 psi Polyiso Insulation Laid) ' •. i ti.+ .. +. •.. of ♦ t r .. r f (Loose 3.1" Sarnatherm 20 psi Polyiso Insulation • • A (Loose Laid) i SarnafastenerXP Fastener W/Plate ") Y:",Plywood Deck (Existing) 1 1 BASE FLASHING COMPONENTS Sarnafil G459 60 mil White Roof Membrane (Adhered) Over Asphalt contaminated surfaces V SarnacoI2170 i Adhesive Waynes Roofing; Inc.,GatewayNorth 13105 Houston Road Sumner, WA 98390 5u( ) 55 s...a(20S)S75=0078 Bldg 5 - g SYSTEM DESCRIPTION FaX (253)eZ3-831; ,� 1 ,;::.. :1771-e 4/5/17 . 2repored 3y Joe D Rev. Job No. 17-023 Scale N.T.S. Section Sheet 002 (CORNER) 16 PER BD. (PERIMETER) 10 PER BD. (FIELD) 6 PER BD. 2' X 3' RHINOBOND FASTENING PATTERN NOTES; 1) PERIMETER AND CORNER AREAS ARE DETERMINED IN ACCORDANCE WITH ASCE-7: Ko LEAST PLAN WIDTH OR bio ROOF HEIGHT BUT NOT LESS THAN 4 FT. 2) BOARDS CROSSING PERIMETER/CORNER AREA INTO FIELD AREA SHALL BE ATTCHED ACCORDING TO RESPECTIVE PERIMETER/CORNER RATES. 3) FOR HEIGHT > 60 FT, CORNER IS "L" SHAPED WITH DIMENSIONS (2 X "PERIMETER"). XP FASTENER f--3'RHINOBOND-PERIMETER & CORNER ATTACHMENT AND SARNADISC , RHINOBOND BUILDING TRUST 781-828-5400 usa.samafil.sika.com JOB NAME: SCALE: N.T.S. DATE: 5/15 FILE NO.: RB -1 B DRW. NO.: AS A MEMBRANE MANUFACTURER SIKA CORPORATION ('SIKA, REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FORA PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKAAUTHORIZEDAPPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL SALE OF SIKA PRODUCTS AND SERVICES ARE SUBJECT TO SIKH' TERMS AND CONDITIONS OF SALE AVAILABLE AT USA.SARNAFILSIKA.COM. )2 — •I Ja; Sika Sarnafil Roofing Specification Manual Typical System Details MULTI-PURPOSE TAPE CONTINUOUS METAL HOOK STRIP (MIN. 22 GAUGE) METAL COPING CAP WITH WATERTIGHT JOINTS SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE NOTES: 1) NAILERS SHALL BE SECURELY ANCHORED TO THE DECK TO RESIST A MINIMUM FORCE OF 300 POUNDS PER LINEAR FOOT. REFER TO FACTORY MUTUAL DATA SHEET 1-49. 2) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4—INCHES WIDE. 3) VAPOR BARRIER SHALL BE SEALED AT EDGES. 4) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. TREATED WOOD NAILER 0 SECUREMENT FASTENED AT BASE OF WALL OR CURB ALTERNATE BASE FASTENING METAL EXTENDER PIECE AS REQUIRED GROMMETTED FASTENER 12 IN. O.C. SPECIFIED SARNAFIL SECUREMENT HOT-AIR WELD SARNAFIL MEMBRANE "�eteeeek STRUCTURAL DECK AIR / VAPOR BARRIER (AS REQUIRED) INSULATION SECURELY FASTENED PARAPET WAL W H MCE L COPING CAP Sarnafi/. 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/11 FILE NO.: 2-3 DRW. NO.: AS A MEMBRANE MANUFACTURER, SIKA SARNAFIL, A DIVISION OF SIKA CORPORATION REVIEWS DETAILS PREPAR D BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKH SARNAFIL AND IS NOT BEI#G CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT. CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS. AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR S1KH SARNAFIL AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SHEA SARNAFIL MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. 2-12 8-14 ,,{ 8" MIN J SELF -FLASHING UNIT ADDITIONAL WOOD BLOCKING, IF REQUIRED (TO ACHIEVE AN 8 IN. MIN. FLASHING HEIGHT) GROMMETTED FASTENER 12 INCHES O.C. METAL EXTENDER PIECE IF REQUIRED (SEE NOTE) SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE SPECIFIED SARNAFIL SECUREMENT HOT-AIR WELD SARNAFIL MEMBRANE SUBSTRATE AIR / VAPOR BARRIER (AS REQUIRED) INSULATION SECURELY FASTENED NOTE: 1) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 INCHES WIDE. FASTENED 12 INCHES O.C. WITH GROMMETTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. REMOVABLE CURB FLASHING BUILDING TRUST 781-828-5400 usa.samafil.sika.com JOB NAME: SCALE: N.T.S. DATE: 7/23 FILE NO.: 5-1 DRW. NO.: XXX AS A MEMBRANE MANUFACTURER SIKA CORPORATION (MIKA" REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKAAUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL SALE OF SIKA PRODUCTS AND SERVICES ARE SUBJECT TO SIKH' TERMS AND CONDITIONS OF SALE AVAILABLE AT USA.SARNAFIL.SIKACOM. _ Sika Sarnafil Roofing Specification Manual Typical System Details z w U z co NOTES: 1) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 INCHES WIDE. FASTENED 12 INCHES O.C. WITH GROMMETTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. NON—REMOVABLE UNIT GROMMETTED FASTENER 12 INCHES O.C. METAL EXTENDER PIECE WITH SIKAFLEX-1A SEALANT ONTO BACK SIDE SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE SPECIFIED SARNAFIL SECUREMENT HOT—AIR WELD SARNAFIL MEMBRANE STRUCTURAL DECK INSULATION SECURELY FASTENED AIR / VAPOR BARRIER (AS REQUIRED) NONREMOVABLE C R FLASH Sarnafil® 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/11 FILE NO.: 5-2 DRW. NO.: AS A MEMBRANE MANUFACTURER, 51KA SARNAFIL, A DIVISION OF SIKH CORPORATION REVIEWS DETAILS PREPAR D BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKH SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKH SARNAFIL AND IS NOT BEI G CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR HE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPL CATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKH SARNAFIL AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKH SARNAFIL MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. 2-12 8-32 Sika Sarnafil Roofing Specification Manual Topical System Details A' f' z z z 8 INCHES SKYLIGHT/ROOF HATCH UNIT GROMMETTED FASTENER 12 INCHES 0.C. METAL EXTENDER PIECE WITH SIKAFLEX-1A SEALANT ONTO BACK SIDE SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE SPECIFIED SARNAFIL SECUREMENT HOT-AIR WELD SARNAFIL MEMBRANE STRUCTURAL DECK INSULATION SECURELY FASTENED AIR / VAPOR BARRIER (AS REQUIRED) NOTES: 1) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 INCHES WIDE. FASTENED 12 INCHES O.C. WITH GROMMETTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. SKYLIGHT/ ROOF HATCH FLASHING Sarnafil® 781-828-5400sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/1 1 FILE NO.: 5-3 DRW. NO.: AS A MEMBRANE MANUFACTURER, SIKH SARNAFIL, A DIVISION OF SIKA CORPORATION REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJ CT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONST UED AS APPROVAL OF DETAILS BY SIKA SARNAFIL AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APP CATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA SARNAFIL A THORIZED APPLI ATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA SARNAFIL MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. 2-12 8-33 DRAIN STRAINER CLAMPING RING SARNAFIL MEMBRANE FLASHING TAPERED EDGE SECURELY FASTENED AS REQUIRED SARNAFASTENER AND SARNADISC HOT-AIR WELD SARNAFIL MEMBRANE SUBSTRATE AIR / VAPOR BARRIER (AS REQUIRED) INSULATION SECURELY FASTENED SIKAFLEX-14 SEALANT UNDER MEMBRANE AT CLAMPING RING NOTES: 1) EXISTING DRAIN BOWL, CLAMPING RING AND DRAIN ACCESSORIES ARE TO BE CLEANED FREE OF ALL CONTAMINATES. 2) SARNAFIL G459 MEMBRANE MUST BE USED IN AREAS OF ASPHALT CONTAMINATION. 3) VAPOR BARRIER SHALL BE SEALED AT EDGES. CLAVHNG RAG DR N Sarnafil® 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 6/13 FILE NO.: 6-1 DRW. NO.: vvv AS A MEMBRANE MANUFACTURER, SIKA SARNAFIL, A DIVISION OF SIKA CORPORATION REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA SARNAFIL AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SULTABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA SARNAFIL AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA SARNAFIL MEMBIiANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. Sika Sarnafil Roofing Specification Manual Typical System Details NOTES: 1) PIECE OF SARNACLAD METAL CUT TO FIT INSIDE OF VOID AT OPEN END OF GRAVEL - DAM, SECURED IN-PLACE USING POP -RIVETS PRIOR TO COMPLETING FLASHINGS AT SCUPPER BOX. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. 1 METAL SCUPPER BOX SARNACLAD METAL PIECE AT VOID SARNAFIL FLASHING, HOT-AIR WELDED SIKAFLEX-1A SEALANT OR MULTI-PURPOSE TAPE DETAIL AT END OF EDGE METAL REFER TO ABOVE DETAIL •1 • 1 1 SARNACLAD METAL EDGE PIECE AT SCUPPER FASTENED W/GALVANIZED ANNULAR RING NAILS SARNAFIL FLASHING STRIP, HOT-AIR WELDED 1111111 Ung SARNAFIL MEMBRANE vx.x xt 1 INSULATION AIR / VAPOR BARRIER (AS REQUIRED) TREATED WOOD NAILER DETAOL AT SCUPPE BOX Sarnafi/® 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/11 /11 FILE NO.: 6-4 DRW. NO.: AS A MEMBRANE MANUFACTURER, SIKH SARNAFIL, A DIVISION OF SIKH CORPORATION REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA SARNAFIL AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA SARNAFIL AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA SARNAFIL MEMBRANE. ARE THE RESPONSIBILITY OF THE CONTRACTOR, 2-12 8-37 • i Ob • 8 INCHES PIPE PENETRATION SIKAFLEX-1A SEALANT (SEE NOTE) STAINLESS STEEL HOSE CLAMP SARNAFIL FLASHING MEMBRANE SARNAFASTENER AND SARNADISC SARNAFIL BASE FLASHING, HOT-AIR WELDED SARNAFIL MEMBRANE STRUCTURAL DECK INSULATION SECURELY FASTENED AIR / VAPOR BARRIER (AS REQUIRED) NOTE: 1) SEALANT IS A MAINTENANCE ITEM. MAINTENANCE IS NOT COVERED UNDER SARNAFIL WARRANTY. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. CONE FLASHING AT PENETRATION BUILIDNG TRUST 781-828-5400 usa.samafil.sika.com JOB NAME: SCALE: N.T.S. DATE: 1 /14 FILE NO.: 7-3 DRW. NO.: vvv AS A MEMBRANE MANUFACTURER SIKA CORPORATION CSIKA•) REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT ANDIOR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT ANDIOR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FORA PARTICULAR PROJECT OR APPLICATION. WHILE SIKA PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL SALE OF SIKA PRODUCTS AND SERVICES ARE SUBJECT TO SIKH' TERMS AND CONDITIONS OF SALE AVAILABLE AT USASARNAFIL.SIKACOM. Sika Sarnafil Roofing Specification Manual Typical System Details -70 • INCHES MIN. co. J NOTES: • • PIPE PENETRATION SIKAFLEX-1A SEALANT (SEE NOTE) STAINLESS STEEL HOSE CLAMP ALUMINUM TAPE (SEE NOTE) SARNAFIL FLASHING MEMBRANE SARNAFASTENER AND SARNADISC -Tl iertirrt SARNAFIL BASE FLASHING, SARNAFIL MEMBRANE STRUCTURAL DECK INSULATION SECURELY FASTENED AIR / VAPOR BARRIER (AS REQUIRED) 1) ALUMINUM TAPE IS REQUIRED IF EXISTING PENETRATION IS CONTAMINATED. 2) SEALANT IS A MAINTENANCE ITEM, MAINTENANCE IS NOT COVERED UNDER THE SARNAFIL WARRANTY. 3) VAPOR BARRIER SHALL BE SEALED AT EDGES. PRE DENETRATION FLASH Sarnafil® 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/11 FILE NO.: 7-2 DRW. NO.: AS A MEMBRANE MANUFACTURER. SIKH SARNAFIL, A DIVISION OF SIKA CORPORATION REVIEWS DETAILS PREPARED BY THE CONSULTANT. ARCHITEC AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKH SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW I5 NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA SARNAFIL AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUM S NO LIABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS T E SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA SARNAFIL A THORIZED APPLICATORS. THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA SARNAFIL MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. 2-12 8-39 METAL CURB (OPTIONAL) z z —z • co FIBERGLASS BATTEN STAINLESS STEEL HOSE CLAMP HOT STACK RAIN COLLAR WITH HIGH TEMPERATURE SEALANT —SARNAFIL FLASHING MEMBRANE SARNAFASTENER AND SARNADISC — SARNAFIL BASE FLASHING, HOT—AIR WELDED Nirtorre SARNAFIL MEMBRANE STRUCTURAL DECK INSULATION SECURELY FASTENED AIR / VAPOR BARRIER (AS REQUIRED) NOTES: 1) SARNAFIL MEMBRANE SHALL NOT BE IN CONTACT WITH SURFACES HAVING SUSTAINED TEMPERATURES ABOVE 1 60°F. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. HEATED STACK FLASHING BUILDING TRUST 781-828-5400 usa.samafil.sika.com JOB NAME: SCALE: N.T.S. DATE: 7/23 FILE NO.: 7-4 DRW. NO.: vvv AS A MEMBRANE MANUFACTURER SIKA CORPORATION rSIKA') REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITECT AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW I5 NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKH CORPORATION ASSUMES NO UABILITY WITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FOR A PARTICULAR PROJECT OR APPLICATION. WHILE SIKA PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA AUTHORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. ALL SALE OF SIKA PRODUCTS AND SERVICES ARE SUBJECT TO SIKA' TERMS AND CONDITIONS OF SALE AVAILABLE AT USA.SARNAFIL.SIKA.COM. I a Sika Sarnafil Roofing Specification Manual Typical System Details INSULATION SECURELY FASTENED SARNAFIL MEMBRANE AIR / VAPOR BARRIER (AS REQUIRED) HOT-AIR WELD SPECIFIED SARNAFIL SECUREMENT SARNAFIL FLASHING MEMBRANE ADHERED TO ACCEPTABLE SURFACE METAL CAP FLASHING STRUCTURAL DECK TREATED WOOD BLOCKING SECURELY FASTENED NOTES: 1)NAILERS SHALL BE SECURELY ANCHORED TO THE DECK TO RESIST A FORCE OF 300 POUNDS PER LINEAL FOOT IN ANY DIRECTION. 2)VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. EQUIPMENT SUPPORT ® Sarnafi/® 781-828-5400 sikacorp.com JOB NAME: SCALE: N.T.S. DATE: 1/11 FILE NO.: 8-3 DRW. NO.: AS A MEMBRANE MANUFACTURER, SIKA SARNAFIL, A DIVISION OF SIKA CORPORATION REVIEWS DETAILS PREPARED BY THE CONSULTANT, ARCHITEC AND/OR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A SIKA SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY SIKA SARNAFII. AND IS NOT BEING CONDUCTED IN LIEU OF SOUND ENGINEERING AND ARCHITECTURAL PRACTICES AND JUDGMENT AND SHOULD NOT BE RELIED UPON FOR THAT PURPOSE. SIKA CORPORATION ASSUMES NO LIABILITYAWITH RESPECT TO THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM. THE ARCHITECT, CONSULTANT AND/OR ENGINEER OR DESIGN PROFESSIONAL FOR A PARTICULAR PROJECT BEARS THE SOLE RESPONSIBILITY FOR THE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM, FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP DRAWINGS, AND FOR DETERMINING THEIR SUITABILITY FO A PARTICULAR PROJECT OR APPLICATION, WHILE SIKA SARNAFIL PROVIDES GENERAL INSTRUCTIONS FOR THE INSTALLATION OF ITS MEMBRANE AS WELL AS TRAINING FOR SIKA SARNAFIL A THORIZED APPLICATORS, THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE MEANS AND METHODS EMPLOYED BY THE CONTRACTOR IN THE INSTALLATION OF THE SIKA SARNAFIL MEMBRANE ARE THE RESPONSIBILITY OF THE CONTRACTOR. 2-12 8-53 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com WAVE'S HOOFING, INC. 4.4 1 ff— . ,1 air .. tl,I•u,I SUMNER, WN PRODUCT DATA 2 PRODUCT DATA SHEET SARNATHERM® - 20 psi Sarnatherm is a rigid closed cell polyisocyanurate insulation board with fiber reinforced felt facers. Sarnatherm is suitable for use in new construction and re -roofing with Sarnafil® or Sikaplan® membranes. PRODUCT INFORMATION USES Wherever insulation is required within a conventional roof assembly to achieve specified thermal resistance. AREAS OF APPLICATION • New Roofs • Recover Roofs • Mechanically Fastened Systems • Adhered Systems FEATURES / BENEFITS • Manufactured with no CFCs or HCFCs • Virtually no GWP (global warming potential) • Zero ODP (ozone depletion potential) • Compatible with Sarnafil and Sikaplan membranes CODES / APPROVALS • ASTM C 1289 Type II, Class 1, Grade 2 (20 psi) • UL 1256, 790, 263 • FM 4450, 4470 • Miami -Dade County • State of Florida PRODUCT DATA COMPOSITION • Polyisocyanurate Foam Core • Fiber Reinforced Felt Facers COLOR Off -White Core with Dark Brown Facer 1/3 01-26-15 Version #1 PACKAGING • 4' x 4' (1.2 m x 1.2 m) • 4' x 8' (1.2 m x 2.4 m) • Various Thicknesses STORAGE STORAGE CONDITIONS Factory -applied packaging is intended only for protection during transit. When stored outdoors or on the job site, the insulation should be stacked on pallets at least 4 in (102 mm) above ground level and completely covered with a weatherproof covering such as a tarpaulin. The temporary factory -applied packaging should be slit or removed to prevent accumulation of condensation. Refer to PIMA Technical Bulletin 109: Storage and Handling Recommendations for Polyiso Roof Insulation. TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES* Property ASTM Test Method Results Compressive Strength D 1621 20 psi (138 kPa) Dimensional Stability D 2126 < 2 % Water Absortion C 209 < 1.5 % Water Vapor Transmission E 96 < 1.5 perm (85.5 ng / (Paosom2)) Flame Spread E 84 (10 min.) 40-60** Smoke Development E 84 (10 min.) 50-170** Service Temperature - -100° to 250° F (-73° to 121° C) *Physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. **Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of <_ 75 and smoke development <_ 450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic insulation when used in FM 4450 or UL 1256. 3.1"=R18 THERMAL DATA LTTR Value* Thickness Flute Spanability in mm in mm 5.7 1.0 25 2 - 5/8 66.68 8.6 1.5 38 4 - 3/8 111.13 10.3 1.8 46 4 - 3/8 111.13 11.4 2.0 51 4 - 3/8 111.13 14.4 2.5 64 4 - 3/8 111.13 15.0 2.6 66 4 - 3/8 111.13 17.4 3.0** 76 4 - 3/8 111.13 20.5 3.5** 89 4 - 3/8 111.13 23.6 4.0** 102 4 - 3/8 111.13 *LTTR (long term thermal resistance) values are based on ASTM C 1289. Test samples were third -party selected and tested by an accredited material testing laboratory. The LTTR results were reviewed by FM Global and certified by the PIMA Quality Mark Program. **Use multiple layers when the total desired or specified R -value requires an insulation thickness greater than 2.7 in (68.58 mm). Product Data Sheet North America Sarnatherm - 20 psi Insulation 01-26-15, VERSION 61 2/3 BUILDING TRUST SYSTEM INFORMATION INSTALLATION Sarnatherm is installed by a Sika Authorized Applicator. Sarnatherm may be installed by mechanical -attachment to the roof deck with Sarnafasteners and Sarnaplates, by attachment with Sarnacol Board Adhesive, or by hot asphalt depending on project requirements and specifications. Roof insulation which has become wet or damaged should be removed and replaced with solid, dry insulation. Contact Sika Corporation — Roofing Technical Department regarding alternative methods of attachment. MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied product, Sarnatherm is covered under Sika 'Corporation warranties. LEGAL NOTES All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or, instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any SIka materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPUED SHALLAPPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com Product Data Sheet North America Sarnatherm — 20 psi Insulation 01-26-15, VERSION #1 3/3 BUILDING TRUST Product Data Sheet Edition: 09/2012 Version no.: 0001 Sarnatherm Roof Board -H Overview: Sarnatherm Roof Board -H is a lightweight, high-density polyisocyanurate roof board for new, re-cover and re -roof applications. The coated fiber glass facers provide strong, smooth surfaces suitable for mechanically at- tached or fully adhered membranes. Composition: Sarnatherm Roof Board -H is high-density polyisocyanurate with fiber glass - reinforced facers. Sarnatherm Roof Board -H is provided in a 4 ft. x 8 ft. (1.2 m x 2.4 m) board size and in a thickness of 1/2 inch (13 mm). Features: • Lightweight for easy hoisting, staging and maneuvering • High impact and flexural strength • Improved resistance to foot traffic and normal roof maintenance • Low water absorption • Easy scoring, cutting and snapping • UL Classified 790 • FM Approved (consult RoofNav for specific assemblies) Packaging: Sarnatherm Roof Board -H is packaged 96 pieces per bundle. Weight per sheet is 11 lbs. (4.9 kg). Protect Sarnatherm Roof Board -H from damage and moisture during transportation and storage. Installation: Sarnatherm Roof Board -H is installed by a Sika Sarnafil Authorized Ap- plicator by mechanical -attachment to the roof deck with approved fasteners and plates. Attachment with specialized adhesive(s), options dependent on deck type and Sika Sarnafil system to be installed. Maximize board lengths to minimize end joints with end joints staggered. Drive fasteners firmly against and flush with surface of Sarnatherm Roof Board -H. Sarnatherm Roof Board -H is cut by scoring and breaking. Do not install more Sarna - therm Roof Board -H than can be covered with welded Sarnafil membrane in that day. Availability: Sarnatherm Roof Board -H is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roof System. Contact your Sika Sarnafil Regional Office or visit our website for further information. Warranty: As a Sika Sarnafil supplied accessory, Sarnatherm Roof Board -H is in- cluded in Sika Sarnafil's System Warranty to the Building Owner. Sarnafil® Maintenance: Sarnatherm Roof Board -H requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation methods of Sarnatherm Roof Board -H. Technical Data (as manufactured): Property Thickness, nominal Width, standard Length, standard Pieces per pallet Weight per sheet (4x8 sheet) Test Method Dimensional Stability "R" Value Water Absorption, % max Compressive Strength, Mold Resistance Service Temperature Recycled Content Flame Classification ASTM D 2126 ASTM C 518 ASTM C 209 ASTM D1621 ASTM D3273 L 13 mm 4' (1220 mm) 8' (2440 mm) 96 11 Ib. <0.5% (linear change 7 days) 2.5 <1% Volume >100psi Passed (10) 260 F or less >8% FM Approved (consult RoofNav for specific assemblies) UL Classified 790 Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') conceming Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.sarnafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. PRODUCT DATA SHEET SIKAPLAN® FASTENED ENERGYSMART ROOF® MEMBRANE _45 X60 _FELTBACK rgySmart Roof` Sikaplan Fastened EnergySmart Roof Membrane is a highly reflective white, nominal thickness PVC membrane with polyester scrim reinforcement offered in nominal 45 mil and 60 mil thicknesses. It is also available in feltback which is manufactured with a recycled felt backing. PRODUCT INFORMATION USES Sikaplan Fastened EnergySmart roof membrane is mechanically fastened using various attachment components over various substrates. AREAS OF APPLICATION • In -seam disc attachment • In -seam batten, double -weld attachment • RhinoBon& attachment FEATURES / BENEFITS • Highly dimensionally stable • Heat welded seams CODES / APPROVALS • FM Global • Underwriters Laboratories • Underwriters Laboratories of Canada • California Title 24 • USGBC LEED • Green Globes Product Data Sheet North America Sikaplan Fastened EnergySmart Membrane 07-01-14, VERSION 01 1/4 PRODUCT DATA COMPOSITION Thermoplastic PVC membrane containing ultraviolet light stabilizers, flame retardant and integral reinforcement with a unique lacquer coating on the top surface. COLOR White top surface, dark gray bottom surface PACKAGING • Sikaplan Fastened 45 EnergySmart 10 ft x 150 ft rolls, 420 lbs per roll, 8 rolls per pallet 5 ft x 150 ft rolls, 210 lbs per roll, 12 rolls per pallet • Sikaplan Fastened 60 EnergySmart 10 ft x 100 ft rolls, 350 lbs per roll, 8 rolls per pallet 5 ft x 100 ft rolls, 175 lbs per roll, 12 rolls per pallet • Sikaplan Fastened 45 EnergySmart Feltback 10 ft x 100 ft rolls, 344 lbs per roll, 9 rolls per pallet • Sikaplan Fastened 60 EnergySmart Feltback 10 ft x 100 ft rolls, 403 lbs per roll, 9 rolls per pallet STORAGE STORAGE CONDITIONS Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability. Product Data Sheet North America Sikaplan Fastened EnergySmart Membrane 07-01-14, VERSION #1 2/4 BUILDING TRUST TECHNICAL DATA Parameters ASTM Test Method ASTM Type III D-4434 Spec. Requirement Typical Physical Properties* Reinforcing Material -- -- Polyester Polyester Overall Thickness, mil D751 45 45 (nominal) 60 (nominal) Thickness Above Scrim, mil -- 16 20 26 Felt Weight, oz/yd2 (feltback membrane only) -- -- 9 9 Breaking Strength M.D., Ibf/in. (KN/m) D751 200 (35) 230 (40) 303 (53) Elongation at Break, % M. D. & % C.M.D.1 D751 15 & 15 20 & 2(3 20 & 20 Seam Strength, % of original2 D751 75 Pass Pass Retention of Properties After Heat Aging D3045 -- -- -- Tensile Strength, % of original D751 90 Pass Pass Elongation, % of original 0751 90 Pass Pass Tearing Resistance, Ibf (N) D1004 45 (200) 45 (200) 45 (200) Low Temperature Bend, -40°F (-40°C) D2136 Pass Pass Pass Accelerated Weathering Test (Florescent Light UV exposure) G154 5,000 Hours 10,000 Hours 10,000 Hours Cracking (7x magnification) -- None None None Discoloration (by observation) -- Negligible Negligible Negligible Crazing (7x magnification) -- None None None Linear Dimensional Change, % D1204 0.5% max. 0.31 0.24 Weight Change After Immersion in Water, % D570 ± 3.0% max. 2.9 2.5 Static Puncture Resistance, lbf (N) D5602 33 (147) Pass Pass Dynamic Puncture Resistance, ft-Ibf (J) 05635 14.7 (20) Pass Pass Recycled Content -- -- 9% Pre -consumer, 1% Post -consumer *Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions, and curing conditions. 1 M.D. = Machine Direction, C.M.D. = Cross Machine Direction 2 Failure occurs through membrane rupture not seam failure. INITIAL SOLAR 3 -YEAR SOLAR INITIAL 3 -YEAR INITIAL SOLAR 3 -YEAR SOLAR REFLECTANCE REFLECTANCE THERMAL THERMAL REFLECTANCE REFLECTANCE EMITTANCE EMITTANCE INDEX INDEX Sikaplan Fastened 45 EnergySmart White 0.83 0.64* 0.89 Pending 104 Pending Sikaplan Fastened 60 EnergySmart White 0.85 0.66* 0.89 Pending 107 Pending *Derived using the California Title 24 calculation method for aged solar reflectance per Section 110.8(1)2. of the 2013 Building Energy Efficiency Standard, page 102. Product Data Sheet North America Sikaplan Fastened EnergySmart Membrane 07-01-14, VERSION #1 3/4 BUILDING TRUST SYSTEM INFORMATION APPLICATION Sikaplan Fastened EnergySmart Roof Membrane is installed by Sika Corporation Roofing Authorized Applicators. Sikaplan Fastened EnergySmart Roof Membrane is installed on acceptable substrates with approved mechanical fasteners. All seams are hot-air welded for watertight protection. Sikaplan Fastened EnergySmart Roof Membrane can be used for flashings on Sikaplan Fastened EnergySmart Roof Membrane roof projects. MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY Upon successful completion of the installed roof by the Sika Authorized Applicator, Sika Corporation will provide a warranty to the Building Owner via the Sika Authorized Applicator. LEGAL NOTES All information provided by Sika Corporation ("Sika") conceming Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or By calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical Service Department at 800.451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPUED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE UABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HEW BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON LST 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com Product Data Sheet North America Sikaplan Fastened EnergySmart Membrane 07-01-14, VERSION #1 4/4 BUILDING TRUST ii Product Data Sheet Edition: 3/2008 Version no.: 0001 Sarnadisc RhinoBond Overview: Sarnadisc RhinoBond is a specially designed, polymer coated plate used with Sarnafasteners to attach insulation or cover boards directly to the roof deck or structural purlins prior to the installation of the Sika Sarnafil membrane. The membrane will be welded to the Sarnadisc RhinoBond by induction welding. Composition: Sarnadisc RhinoBond is a 3 inch (75 mm) diameter, 0.028 inch (0.7 mm) thick metal plate with a polymer coating, meeting the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnadisc RhinoBond has a recessed center to provide protection to the membrane underside from abrasion by the fastener head. Packaging: Sarnadisc RhinoBond is packaged in Pails of 500. Each pail weighs ap- proximately 54 lbs (24 kg). Installation: Sarnadisc RhinoBond is positioned on the surface of the insulation board. A Sarnafastener is set through the center of the disc and set into the roof deck or purlin. The Sarnadisc RhinoBond holds the insulation in place. Availability: Sarnadisc RhinoBond is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil roof system. Contact your Sika Sarnafil Regional Office or visit our website for further information. Warranty: As a Sika Sarnafil supplied accessory, Sarnadisc RhinoBond is included in Sika Sarnafil's Standard or System Warranty Ito the Building Owner. Samafile Maintenance: Sarnadisc RhinoBond requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation, method. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer: The information, and, in particular, the recommendation relating to the application and end-use of Sika Samafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Samafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnalil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. PRODUCT DATA SHEET SIKAPLAN® FASTENER #15 Sikaplan Fastener #15 is a threaded drill point fastener used within Sikaplan roof systems to attach Sikaplan Fastened or Sarnatherm® insulation, Sarnatherm roof boards, gypsum roof boards, or other Sika approved boards into steel decking (18-24 gauge), wood plank (min. 1-1/2"), or wood sheathing (>15/32"). PRODUCT INFORMATION USES Used in conjunction with Sikaplan discs or plates, or Sarnarail for attachment direct to the roof deck. AREAS OF APPLICATION • New Roof Applications • Reroof Applications FEATURES / BENEFITS • Oversized heavy shank and thread diameters. • Deep buttress threads for high pullout resistance. • Miniature drill point penetrates decks quickly and contributes to exceptional resistance to back out. CODES / APPROVALS • Factory Mutual 4470 • Miami -Dade County PRODUCT DATA FORM COMPOSITION Made from carbon steel, treated with a corrosion -resistant coating to meet the criteria for corrosion resistance. • Thread Diameter: 0.245 inch (6.2 mm) • Shank Diameter: 0.203 inch (5.2 mm) • Head Diameter: 0.435 inch (11 mm) • Head Style: #3 Phillips COLOR Black 1/3 2-22-16 Version # 1 PACKAGING Length Thread Packaging Weight 1-1/4 inch (32 mm) Full 1000 / Pail 12 Ib (5.4 kg) (512 1nch mm) Full 1000 / Pail (9.1k0 9 (7) 6 mm) mm) Full 1000 / Pail (13.2h 29 b 1 g) 4 inch (102 mm) 3 inch • (76 mm) 1000 / Pail 38 Ib (17.2 kg) 5 inch (127 mm) 4 inch (102 mm) 500 /Pail 24 Ib (10.9 kg) 6 inch (152 mm) 4 inch (102 mm) 500 /Pail 28 Ib (12.7 kg) 7 inch (178 mm) 4 inch (102 mm) 500 /Pail 34 Ib (15.4 kg) 8 inch (203 mm) 4 inch (102 mm) 500 /Pail 38 Ib (17.2 kg) 9 inch (229 mm) 4 inch (102 mm) 500 / Box 42 Ib (19.1 kg) 10 inch (254 mm) 4 inch (102 mm) 500 / Box 47 Ib (21.3 kg) 12 inch (305 mm) 4 inch (102 mm) 500 / Box 56 Ib (25.4 kg) 14 inch (356 mm) 4 inch (102 mm) 250 / Box 32 Ib (14.5 kg) 16 inch (406 mm) 4 inch (102 mm) 250 / Box 38 Ib (17.2 kg) 18 inch (457 mm) 4 inch (102 mm) 250 / Box 41 Ib (18.6 kg) 20 inch (508 mm) 4 inch (102 mm) 250 / Box 44 Ib (20 kg) * One #3 Phillips drive bit is included in each box. SYSTEM INFORMATION INSTALLATION INSTRUCTIONS The Sikaplan Fastener #15 is fastened straight into the roof deck with a heavy-duty (4 amp minimum), variable speed (0-2500 rpm), reversible screwgun with a clutch release and a #3 Phillips drive bit. Sikaplan Fastener #15 must penetrate steel and wood plank roof decks by 1 inch (25 mm) and the underside of wood sheathing roof decks by a 1/2 inch (13 mm). Care must be taken not damage the roof deck. Choose the correct fastener length and do not overdrive or underdrive the fastener. Pullout tests are required prior to job start when used with existing wood sheathing roof decks for technical evaluation. AVAILABILITY From Authorized Applicators when used within Sikaplan roofing systems. MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied accessory, Sikaplan Fastener #15 is covered under Sika Corporation warranties. Product Data Sheet North America Sikaplan Fastener 1415 Fastener 2-22-15, VERSION #1 2/3 BUILDING TRUST Product Data Sheet Edition: 11/2013 Version no.: 0009 For Use at Asphalt Contaminated Base Flashings G459 Flashing Membrane Overview: G459 flashing membrane is a heat -weldable roofing membrane formulated for direct exposure to the weather and is produced with an integral fiber- glass mat reinforcement for dimensional stability. G459 flashing membrane is used to flash roof penetrations within a Sika Samafil roof system. G459 flashing membrane can be adhered directly to asphalt or other contami- nated surfaces. Composition: G459 flashing membrane is a high quality product containing PVC resin, pigments, stabilizers, ultraviolet absorbers, and a fiberglass carrier sheet. G459 flashing membrane comes in 6.5 ft. x 65 ft. and 3.25 x 65 ft. options and is 60 mil (1.5mm) thick. The standard color is white on tan. The tan side of the membrane must be the side exposed to the contamination. Features: G459 flashing membrane's glass reinforcement makes it highly dimension- ally stable which is ideal for adhered flashing applications at walls, termina- tions and penetrations. G459 flashing membrane is resistant to asphalt and many other rooftop contaminates. Sika Samafil recommends testing for compatibility. Contact Sika Samafil's Corporate or Regional Offices. Codes and Approvals: Sika Samafil's Adhered Systems using G410 PVC membranes are clas- sified by Underwriters Laboratories, Inc., Underwriters Laboratories of Canada, FM Global, Miami -Dade and Florida Building Code. Sika Samafil membranes also meet the material requirements of International building code. Packaging: G459 flashing membrane rolls are provided individually and are sealed for shipping. Individual rolls are 168 lbs for 6.5 ft. x 65 ft. and 83 lbs for 3.25 x 65 ft. Installation: G459 flashing membrane is installed by Sika Samafil Authorized Applicators on walls curbs and certain other penetrations using Sika Samafil's Samacol adhesives. The seams are then heat welded together by trained operators using Sika Samafil's hot-air welding equipment. Availability: G459 flashing membrane is available directly from Sika Samafil Authorized Applicators. Contact your Sika Samafil Regional Office or visit our website for further information. Sarnafil® Warranty: As a Sika Samafil-supplied accessory, 0459 flashing membrane is included in Sika Samafil's Standard or System Warranty to the Building Owner. Maintenance: G459 flashing membrane requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to advise Applicators as to the correct installation methods of 0459 flashing membrane. Technical Data (as manufactured): Parameters Reinforcing Material Overall Thickness, min., inches (mm) Tensile Strength, min., psi (MPa) Elongation at Break, min. Seam Strength*, min., (% of tensile strength) Retention of Properties After Heat Aging Tensile Strength, min., (% of original) Elongation, min., (% of original) Tearing Resistance, min., Ibf (N) Low Temperature Bend, -40 °F (-40 °C) Accelerated Weathering Test (Florescent Light, UV exposure) Cracking (7x magnification) Discoloration (by observation) Crazing (7x magnification) Linear Dimensional Change Weight Change After Immersion in Water Static Puncture Resistance, 33 Ibf (15 kg) Dynamic Puncture Resistance, 7.3 ft-Ibf (10 J) ASTM Test Method D638 D638 D638 D638 D3045 D638 D638 D1004 D2136 G154 D1204 D570 D5602 D5635 Typical Physical Properties Fiberglass 0.060 (1.5) 1600 (11.1) 270% M.D. 250% C.M.D. 80 95 90 14 (63.0) Pass Pass None Negligible None 0.02% 2.5% Pass Pass Failure occurs through membrane rupture not seam failure. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika. Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905)670-5278 Web: can.sika.com Disclaimer. All information provided by Sika Corporation ('Sika' concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's curent experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sikes instructions. Jn practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shell any legal relationship be created by or arise from the provision of such Information, advice, recommendations or instructions related to Its products. The user of the Sika product(s) must test the product(s) for suitability for the Intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Ma product(s) are subject to its current terms and conditions of sale which are available at usa.samafil.slka.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.samafil.snka.com or by calling Sika's Technical Service Department at 800.451-2504. Nothing contained In any Sika materials relieves the user of the obligation to read and follow the warnings and Instruction for each Sika product as set forth In the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTEL- LECTUAL PROPERTY RIGHTS HELD BY OTHERS. BUILDING TRUST PRODUCT DATA SHEET SARNACOL® 2170 (Applied @ Base Flashing Membrane) Sarnacol® 2170 membrane adhesive is a solvent -based reactivating adhesive used within a Sarnafil® adhered roofing and waterproofing system. It is also used to adhere flashings in any Sarnafil system. It is formulated for adhering Sarnafil PVC membranes to properly prepared substrates such as wood, sheet steel, masonry, concrete, insulations and approved coverboards. PRODUCT INFORMATION USES Sarnacol 2170 is uniquely formulated to be compatible with Sarnafil membranes. AREAS OF APPLICATION Bareback Membrane Substrates • Isocyanurate Organic Facer • Isocyanurate Glass Facer • Smooth Plywood • Metal • Concrete Wall • DensDeck® • DensDeck Prime® • Securock® Gypsum Fiber Feltback Membrane Substrates • Isocyanurate Organic Face • Isocyanurate Glass Facer • Smooth Plywood • Metal • Concrete Deck • Concrete Wall • Masonry Wall • Cellular Concrete • DensDeck® • DensDeck Prime® • Securock® Gypsum Fiber PRODUCT DATA FORM COMPOSITION Liquid COLOR Dark Yellow PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT USA.SARNAFIL.SIKA.COM OR BY CALLING SIKA SARNAFIL'S TECHNICAL SERVICE DEPARTMENT AT BOO451-7500. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE. 1/4 10-01-14 Version # 1 VOC CONTENT 694.2 g/I PACKAGING 5 gallon (18.9 L) pails, 45 lbs (20.4 kg) per pail, 48 pails per pallet. STORAGE STORAGE CONDITIONS Store materials in a dry area between -4°F (-20°C) and 86°F (30°C) with careful handling to prevent damage to products. Do not store at high temperatures or in direct sunlight. Keep lids tightly closed when not in use. Protect all materials from freezing and other damage during transit, handling, storage, and installation. SHELF LIFE 12 months if stored properly in original unopened, sealed and undamaged packaging. SYSTEM INFORMATION APPLICATION INSTRUCTIONS SURFACE PREPARATION All surfaces must be clean, dry, and free of dirt, grease, oil, or other contaminants or particulates. MIXING Mix well before use. APPLICATION METHOD / TOOLS Bareback: Sarnacol 2170 is roller -applied to both the membrane and the substrate in the following manner: Apply Sarnacol 2170 to the substrate and allow to dry. After the substrate adhesive has dried completely, apply Sarnacol 2170 to the back side of the membrane, and allow to become tacky (producing strings) when touched with a dry finger. The Sarnacol 2170 on the membrane shall not be permitted to dry completely. The membrane is then placed on the substrate (mating adhesive surfaces). The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions (vertical flashings are hand -rolled). Feltback: Sarnacol 2170 is roller -applied to the substrate and allowed to dry completely. A second coat of adhesive is then applied to the substrate. The second coat of adhesive shall not be permitted to dry completely. The membrane is then placed on the substrate while the adhesive is still wet. The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions. Installation Note: These installation instructions are a condensed version for the product data sheet. Before installing the membrane with Sarnacol 2170, read the complete instructions detailed in the applicator handbook. PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT USA.SARNAFIL.SIKA.COM OR BY CALLING SIKA SARNAFIL'S TECHNICAL SERVICE DEPARTMENT AT 800-451-2504. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE. 2/4 10-01-14 Version # 1 Sarnacol 2170 BUILDING TRUST COVERAGE Bareback Membrane Substrates Isocyanurate Organic Facer 1-% G/Sq. (0.71 L/M2) Isocyanurate Glass Facer 1-Y2 G/Sq. (0.61 L/M2) Smooth Plywood 1-Y2 G/Sq. (0.61 L/M2) Metal 1-Y, G/Sq. (0.51 L/M2) Concrete Wall 1-% G/Sq. (0.71 L/M2) Dens -Deck® 1-3a G/Sq. (0.71 L/M2) Dens -Deck Prime® 1-Y2 G/Sq. (0.61 L/M2) Securock• Gypsum -Fiber 1-Y2 G/Sq. (0.61 L/M2) Feltback Membrane Substrates Isocyanurate Organic Facer 2-Y4 G/Sq. (0.92 L/M2) Isocyanurate Glass Facer 2 G/Sq. (0.81 L/M2) Smooth Plywood 2 G/Sq. (0.81 L/M2) Metal 1-3 G/Sq. (0.71 L/M2) Concrete Deck 2-34 G/Sq. (0.92 L/M2) Concrete Wall 2-11 G/Sq. (0.92 L/M2) Masonry Wall 2 -Ye G/Sq. (0.921/M2) Cellular Concrete 2 -Ye G/Sq. (0.92 [L/M2) Dens -Deck® 2-Y. G/Sq. (0.92 1/M2) Dens -Deck Prime® 2 G/Sq. (0.81 L/M2) Securock® Gypsum -Fiber 2 G/Sq. (0.81 L/M2) PRODUCT LIMITATIONS LIMITATIONS: Precautions should be taken to prevent odors and/or vapors from entering the building/structure, including but not limited to turning off and sealing air intake vents or other means of ingress for odors and/or vapors into the building/structure during product application and cure. • Do not apply in wet weather or to a wet surface. • Open time varies depending on weather and temperature conditions. • The open time will be shorter on hot days and longer on cold dry days. PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCTS MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT USA.SARNAFIL.SIKA.COM OR BY CALLING SIKA SARNAFIL'S TECHNICAL SERVICE DEPARTMENT AT 800-451-2504. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE. 3/4 10-01-14 Version # 1 Sarnacol 2170 BUILDING TRUST • Eliminate uneven surfaces to ensure positive contact,between the membrane and the substrate. • Unused adhesive can be saved for use at a later date by simply replacing the pail cover. AVAILABILITY From Authorized Applicators when used within Sarnafil or Sikaplan roofing and waterproofing systems. MAINTENANCE Standard maintenance of roofs, green roofs and plaza decks should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied accessory, Sarnacol 2170 is covered under Sika Corporation warrantees. LEGAL NOTES All Information provided by Sika Corporation ('Sika') concerning Sika products, Including but not limited to, any recommendations and advice relating to the application and use of Sika products, Is given In good faith based on Sika's current experience and knowledge of Its products when properly stored, handled and applied under normal conditions in accordance with Sika's Instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability, for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to Its products. The user of the Sika product(s) must test the product(s) for suitability for the Intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of Its products without notice. All sales of Sika product(s) are subject to Its current terms and conditions of sale which are available at usasarnafll.sika.com or by calling NO - 451 -2504. 00.451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.samafllsika.com or by calling Ma's Technical Service Department at 800451-2504. Nothing contained In any Sika materials relieves the user of the obligation a read and follow the warnings and Instruction for each Sika product as set forth In the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of Installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet If used as directed within shelf life. User determines suitability of product for Intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPUED SHALL APPLY INCUJDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HEW BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafilCWus.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com PRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS ON THE PRODUCT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET WHICH ARE AVAILABLE ONLINE AT USA.SARNAFIL.SIKA.COM OR BY CALLING SIKA SARNAFIL'S TECHNICAL SERVICE DEPARTMENT AT 800-451-2504. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE. 4/4 10-01-14 Version # 1 Sarnacol 2170 BUILDING TRUST Product Data Sheet Edition: 2/2013 Version no.: 0007 Sarnaclad For use at Scuppers Overview: Samaclad is a heat -weldable flashing product used with Samafil G and S membranes to form a monolithic roofing or waterproofing system. Composition: Samaclad is a 24 gauge, G90 galvanized metal sheet with a 20 mil (0.5 mm) unsupported Samafil membrane laminated on one side. Samaclad is available in seven standard colors. Standard colors are Copper Brown, White, Evergreen, Lead Gray, Light Gray, Patina Green, and Tan. Sika Sar- nafil's Energy Star rated EnergySmart Roof® color family consists of White, Tan, Light Gray, and Patina Green. The dimensions of Samaclad are 4 ft x 8ft(1.2mx2.4m)or4ftx10ft(1.2mx3.Om). Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Features: Samaclad is a durable and attractive flashing product capable of being formed into a Targe variety of shapes and profiles. Heat -welding of Sar- nafil G and S membranes to Samaclad assures watertight integrity. The Samaclad has a unique lacquer coating to resist staining from airbome dirt and pollutants. Packaging: See Technical Data section for information. Installation: Samaclad is cut to size and formed to shape cn standard sheet metal equipment. Samaclad is fastened in position in accordance with Sika Sar- nafil Technical requirements. The Samaclad joints are covered by 2 inch (50 mm) wide aluminum foil tape and then made watertight by heat -weld- ing a 4 inch (100 mm) wide G410 membrane strip over the tape. By use of a Samafil G or S coverstrip, the roofing or waterproofing membrane is then heat -welded to the Samaclad. Availability: Samaclad is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil roofing or waterproofing system. Contact your Sika Samafil Regional Office or visit our website for further informa- tion. Warranty: As a Sika Samafil-supplied accessory, Samaclad is included in Sika Samafil's Standard or System Warranty to the Building Owner. Sarnafil® Maintenance: Samaclad requires no maintenance. Technical Data: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Samaclad. Sheets/Pallet Size 25 4ftx8ft (1.2mx2.4m) Weight/Sheet Weight/Pallet 35 lbs (16 kg) 905 lbs (410.5 kg) 25 4 ft x 10 ft 44 lbs (20 kg) 1,130 lbs (512.6 kg) (1.2mx3.Om) Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. All information provided by Sika Corporation ("Sika) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.semafiLsika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the wamings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which am available at usa.samefiLslke.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. LEGAL NOTES All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa:sarnafil.sika.com or by calling 800- 451-2504. Prim to each use of any Slim product, the user must ahvays read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet whkh are available online at usa.samafll.slka.cam or by calling Slka's Technical Service Department at 800.451-2504. Nothing contained In any Sika materials relieves the user of the obligation to read and follow the warnings and Instruction for each Soca product as set forth In the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life.. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPUED SHALL APPLY INCLUDING ANY WARRANTYOF MEROIANTABIt1TYOR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR 'SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com Product Data Sheet North America Sikaplan Fastener #15 Fastener 2-22-15, VERSION #1 3/3 BUILDING TRUST PRODUCT DATA SHEET DETAIL MEMBRANE (60 MIL) A heat weldable thermoplastic PVC membrane used in Sarnafil® and Sikaplan® roofing and waterproofing flashing details. Detail Membrane is produced with an integral fiberglass mat reinforcement for dimensional stability and is more pliable than Sarnafil G410 flashing membrane making it easier to stretch and weld. Detail Membrane is intended for flashing pipes; inside/outside corners and unusual shaped penetrations. PRODUCT INFORMATION USES For Sarnafil and Sikaplan roofing and waterproofing flashing details AREAS OF APPLICATION • Flashing pipes • Inside/outside corners • Unusual shaped penetrations FEATURES / BENEFITS • More pliable than Sarnafil G410 membrane making it easier to stretch and weld • Reinforced for dimensional stability and durability • Lacquer coated top surface to reduce dirt pick up • Convenient pre-cut rolls PRODUCT DATA FORM COMPOSITION Thermoplastic PVC membrane containing ultraviolet light stabilizers, flame retardant and integral carrier. Detail Membrane has a unique lacquer coating applied to the top surface of the membrane. Available in 60 mil (1.5 mm) thickness. COLORS White, tan or light gray PACKAGING 12" x 50' (30.5 cm x 15.2 m) roll, 20 lbs (9.1 kg) per roll 24" x 50' (61 cm x 15.2 m) roll, 40 lbs (18.2 kg) per roll Product Data Sheet North America DETAIL MEMBRANE Flashings 02-06-14, VERSION 61 1/2 STORAGE STORAGE CONDITIONS Store rolls standing on end on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability. SYSTEM INFORMATION APPLICATION INSTRUCTIONS Detail Membrane is installed by Authorized Applicators on pipes, corners and other roof penetrations. Detail Membrane can be heated slightly and stretched to conform around various shapes. Seams are heat welded together using standard hot air welding tools. Install Detail Membrane with lacquer coated (glossy appearance) side up. AVAILABILITY From Authorized Applicators when used within Sarnafil or Sikaplan roofing and waterproofing systems. MAINTENANCE Standard maintenance of roofs, green roofs and plaza decks should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied accessory, Detail Membrane is covered under Sika Corporation warranties. LEGAL NOTES All Information provided by Sika Corporation ('Sika') concerning Sika products, Including but not limited to, any recommendations and advice relating to the application and use of Sika products, Is given In good faith based on Sika's current experience and knowledge of Its products when properly stored, handled and applied under normal conditions In accordance with Sika's instructions. In practice, the differences In materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or Instructions related tolls products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or Instructions related to Its products. The user of the Sika product(s) must test the product(s) for suitability for the Intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of Its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafll.sika.com or by calling 800- 451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical Service Department at 800451-2504. Nothing oontalned In any Sika materials relieves the user of the obligation to read and follow the warnings and Instruction for each Slim product as set forth In the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of Installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet If used as directed within shelf life. User determines suitability of product for Intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPUED SHALL APPLY INCWDING ANY WARRANTY OFMEROIANrABIt1TYOR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE UABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com Product Data Sheet DETAIL MEMBRANE 02-06-14, VERSION #1 2/2 North America Flashings BUILDING TRUST Product Data Sheet Edition: 04/2013 Version no.: 0002 Sarnastack Universal Overview: Samastack Universal is a 60 mil (1.5 mm) thick prefabricated stack/pipe boot used as a time -saving and attractive part of a Sika Samafil roofing system. Samastack Universal comes in EnergySmart White, Tan and Light Gray. Composition: Samastack Universal is injection molded with the same time -proven formu- lation used in our Samafil membranes. Features: Samastack Universal simplifes the flashing procedures for stack/pipe details reducing the risk of leakage. They are available in one size which accomodates stack/pipe penetrations from 3/4" - 8" (19mm-203mm) in diameter. Samastack Universal is heat -welded in place, becoming an inte- gral part of the Sika Samafil roofing system. Packaging: Samastack Universal is packaged in boxes of 8 pieces and comes with custom made stainless steel clamps. Each box weighs a total of 30 lbs (13.6 kg). Installation: Samastack Universal's lower flange is heat welded in place with a hand- held hot-air welder and roller. The top is then clamped to the stack/pipe using the clamp provided. Sikaflex la is then used to caulk around the top. Availability: Samastack Universal is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. Warranty: As a Sika Samafil supplied accessory, Samastack Universal is included in Sika Samafil's Standard or System Warranty. Samafil® Maintenance: Samastack Universal requires no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Samafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781)828-5365 Web: usa.samafil.sika.com Email: webmaster.samafi I@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.samaffl.slka.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.samafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. PRODUCT DATA SHEET SARNASTACK SPLIT Sarnastack Split is 60 mil (1.5 mm) thick prefabricated pipe boot open along one side to provide a simplified flashing solution for pipes, vent stacks and round penetrations up to 7 inches (178 mm) in diameter when access is obstructed and does not allow for the use of a Sarnastack Universal pipe boot. PRODUCT INFORMATION USES For Sarnafil® and Sikaplan® roofing and waterproofing flashing details AREAS OF APPLICATION • Pipes • Vent stacks • Round penetrations FEATURES / BENEFITS • Time -saving and effective method to flash pipes, vent stacks and round penetrations • Factory fabricated • Only one open seam to heat weld in the field • Available in white, tan and light gray to match the roof membrane color • 3 convenient sizes PRODUCT DATA FORM COMPOSITION Made from Sarnafil G410 60 mil (1.5 mm) roofing membrane. COLORS White, tan or light gray PACKAGING Sarnastack Split A, % in. (19 mm) - 3 in. (76 mm) diameter, 8 per carton. Sarnastack Split B, 2 in. (51 mm) - 5 in. (127 mm) diameter, 8 per carton. Sarnastack Split C, 4 in. (101 mm) - 7 in. (178 mm) diameter, 8 per carton. Each carton includes 8 stainless steel clamping rings. Product Data Sheet North America SARNASTACK SPLIT Flashings 04-01-14, VERSION 01 1/3 STORAGE STORAGE CONDITIONS Store cartons on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of weldability. SYSTEM INFORMATION APPLICATION INSTRUCTIONS Install the insulation and Sika roofing or waterproofing deck sheet tight to the penetration. Secure the deck sheet around the penetration with four Sarnafasteners and Sarnadiscs equally spaced around the penetration. Install the Sarnafasteners and Sarnadiscs as close to the penetration as possible. After securing the Sika deck sheet, install the Sarnastack Split pipe boot as follows. 1. Pull the Sarnastack Split pipe boot around the penetration allowing for a 1 Y" (32 mm) to 1 Y2" (38 mm) overlap at the seam. Trim the top of the pipe boot to provide a tight fit to the penetration. 2. Hold the Sarnastack Split pipe boot in place where the flange meets the pipe boot and tack weld the seam at the flange then at the pipe boot. 3. Pre -weld the flange seam then pre -weld the pipe boot seam. Be careful not to weld the flange to the deck sheet so the Sarnastack Split can be moved and adjusted until final welding. Use the penetration as support for pre -welding and rolling of the pipe boot seam. 4. After pre -welding is complete, continue with the final welding of the seam. Use the penetration as support for the roller to provide pressure and bleed out at the seam. 5. Probe the seam for deficiencies and repair as needed before welding the flange to the deck sheet. 6. Execute the pre -weld and final weld of the flange to the deck sheet. Probe the flange weld and repair any deficiences. 7. Apply a bead of Sikaflex la at the top of the Sarnastack Split between the penetration and split pipe boot. 8. Install the stainless steel clamping ring at the top of the Sarnastack Split creating a seal by compressing the Sikaflex la sealant between the penetration and the split pipe boot. AVAILABILITY From Authorized Applicators when used within Sarnafil or Sikaplan roofing and waterproofing systems. MAINTENANCE Standard maintenance of roofs, green roofs and plaza decks should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied accessory, Sarnastack Splits are covered under Sika Corporation warrantees. Product Data Sheet North America SARNASTACK SPLIT Flashings 04-01-14, VERSION d1 2/3 BUILDING TRUST LEGAL NOTES All Information provided by Sika Corporation ('Sika') concerning Sika products, Including but not limited to, any recommendations and advice relating to the application and use of Sika products, Is given In good faith based on Slka's current experience and knowledge of Its products when properly stored, handled and applied under normal conditions In accordance with Sika's Instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Slka's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to Its products, nor shall any legal relationship be created by or arise from the provision of such Information, advice, recommendations or instructions related to Its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Slice reserves the right to change the properties of Its products without notice. All sales of Sika product(s) are subject to Its current terms and conditions of sale which are available at usa.sarnafll.sika.com or by calling 800- 451-2504. Prior to each use of any Sika product, the user must ahvays read and follow the warnings and Instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usasamafllsika.com or by calling SIka's Technical Service Department at 800.451-2504. Nothing contained In any Sika materials relieves the user of the obligation to read and follow the warnings and Instruction for each Sika product as set forth in the current Product Date Sheet, product bbel and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for Intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCW DING ANY WARRANTY OF MERCHAHTABILITYOR FITNESS FOR A PAR11QILAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION — ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafilPus.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketine.construction@ca.sika.com Product Data Sheet SARNASTACK SPLIT 04-01-14, VERSION 41 North America Flashings 3/3 BUILDING TRUST Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Inside Overview: Samacomers - Inside are a 60 mil (1.5 mm) thick prefabricated comer used as a time -saving and attractive part of a wall, flashing detail. Samacomers - Inside come in EnergySmart white. Composition: Samacomers - Inside are injection molded with the same time -proven for- mulation used in our Samafil membranes. Features: Samacomers - Inside simplify the flashing procedures for inside comer details reducing the risk of leakage. They are available in one size which accomodates most inside comers. Samacomers - Inside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Samacomers - Inside are packaged in boxes of 10 pieces. Each box weighs a total of 30 lbs (13.6 kg). Installation: After the wall flashings are installed, Samacomers - Inside are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Availability: Samacomers - Inside are available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. Warranty: As a Sika Samafil supplied accessory, Samacomers - Inside are included in Sika Samafil's Standard or System Warranty. Samafil® Maintenance: Samacomers - Inside require no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Samafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. The information, and, in particular, the recommendation relating to the application and end-use of Sika Samafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when property stored, handled and applied undernomial conditions in accordance with Sika Samafil recommendations. In practice, the differences in materials, substrates and astral site conditions are such that no war- ranty In respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Samafil reserves the right to change the properties of fts products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concemed, copies of which will be supplied on request. Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Outside Overview: Samacomers - Outside are a 60 mil (1.5 mm) thick prefabricated comer used as a time -saving and attractive part of curb and wall flashing details. Samacomers - Outside are available in EnergySmart white. Composition: Samacomers — Outside are injection molded with the same time -proven formulation used in Samafil membranes. Features: Samacomers — Outside simplify the flashing procedures for various penetrations, reducing the risk of leakage at outside comer details. They are available in one size which will accommodate most outside comers. Samacomers - Outside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Each carton contains 20 outside comers. Each box weighs a total of 30 lbs (13.6 kg). Installation: After the curb or wall flashings are installed, Samacomers - Outside -are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Availability: Samacomers - Outside are available directly, from Sika Samafil Authorized Applicators when used within a Sika Samafil' Roofing or Waterproofing System. Warranty: As a Sika Samafil supplied accessory, Samacomers - Outside are included in Sika Samafil's Standard or System Warranty. Sarnafil® Maintenance: Samacomers - Outside require no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Samafil recommends inspecting the roof system for damage, plugged drains, weathered seal- ants, etc. at least twice a year and after each' storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafi I@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6820;Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. The information, and, in particular, the recommendation relating to the application and end-use of Sika Samafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when property stored, handled and applied under normal conditions in accordance with Sika Samafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty In respect of merchantability of fitness fora particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this Information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Samafil reserves the right to change the properties of Its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concemed, copies of which will be supplied on request. Product Data Sheet Edition: 05/2013 Version no.: 0001 Sarnatred - V Service Side of HVAC Units Access side of Roof Hatch Overview: Samatred-V is a rolled -out, heat welded walkway that has an improved "chevron" design. Samatred-V is used to protect the Sika Samafil mem- brane from foot traffic. Composition: Samatred-V is a 96mi1 (2.4mm) thick, polyester reinforced, membrane made from the same proven formulation as our Samafil membrane. Dimen- sions are approximately 39 inches (1.0 m) wide by 50 feet (15 m) long. Features: Samatred-V is dimensionally stable and durable. Samatred-V is light gray and has a textured surface similar to a chevron pattern. Packaging: Samatred-V is provided in rolls on wood pallets. Installation Roofing membrane to receive Samatred-V shall be dean and dry. Chalk (adhered): lines on deck sheet to indicate location of walkway. Apply a continuous coat of Samacol 2170 adhesive to the deck sheet and the back of Samatred-V in accordance with Sika Samafil's installation requirements for this adhe- sive. Make sure to leave the area on the deck sheet and on the back of the Samatred-V that will be hot-air welded free of adhesive. The entire perimeter of Sarantred-V will be welded. Roll Samatred-V into Samacol 2170 adhesive then press into place with a minimum 1001b linoleum roller. Clean the deck membrane and the back of Samatred-V in areas to be welded if need be. Hot-air weld the entire perimeter of Samatred-V to the Sika Samafil deck sheet. ';Check all welds with a rounded screwdriver. Reweld any inconsistencies. For complete instructions on how to install Sika Samafil walkways, refer to Sika Samafil's Applicator Handbook. Important: Check all existing deck membrane seams that are to be cov- ered by Samatred-V with rounded screwdriver and reweld any inconsis- tencies before walkway installation. Do not use solvent -based adhesive when polystyrene is used as an insulation board in the roof assembly or in geographic areas where voc compliance is not met. Sarnafil® Availability: Samatred-V is available directly from Sika Samafil Authorized Applicators. Contact your Sika Samafil Regional Office or visit our website for further information. Maintenance: Samatred-V may require periodic leaning or removal of leaves and similar debris. Technical: Sika Samafil provides technical support. Tethnical staff is available to ad- vise Applicators as to the correct installation method of SamaTred. Technical Data (as manufactured): ASTM Parameters Test Method Reinforcing Material Overall Thickness, nominal, inches (mm) D751 Tensile Strength, min., psi D751 Elongation at Break, min. D751 Tearing Resistance, min., lbf D751 Low Temperature Bend, -30° F (-40° C) D2136 Fire Resistance E108 UV Resistance D2565 Puncture Resistance (Federal Test) 2065 Recycled Content UL 410 "Slip Resistance of Floor Surface Material" Typical Physical Properties Polyester 0.096 (2.4mm) 275 15% 50 Pass 25 Ft. 5,000 hrs. 54 lbs. 1% Post Consumer / 9% Pre Consumer Pass Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the. application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control, are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.samaftLsika.com or by calling 800451-2504. Prior to each use of any Sika product, the user must always read and follow the wamings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which am available at usa.samafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 5/2009 Version no.: 0005 Aluminium Tape Overview: Aluminum Tape is used as a separation barrier_ between contaminated materi- als and Samafil membrane. Composition: Aluminum Tape is a 25/50 rated aluminum foil tape with a pressure sensi- tive adhesive applied to one side for bonding' to substrates. The adhesive is covered with a paper liner. Features: Aluminum Tape conforms to irregular surfaces. The paper liner removes easily to expose the pressure sensitive adhesive. Packaging: Aluminum Tape is available in lengths of 150 ft (45.7 m) by 2 in (51 mm) wide and comes in rolls of 24 per case. Installation: Aluminum Tape is to be applied to a clean, prepared surface. The surface preparation may include but is not limited to scraping and wiping the surface free of any excessive contaminates. Once the surface has been prepared apply theAluminum Tape to the prepared surface making sure all contaminated areas are covered completely with the Aluminum Tape. Once the Aluminum Tape is applied, make sure it is securely in place and does not allow any contaminates to be exposed to the contact area of the Samafil membrane. Availability: Aluminum Tape is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. Contact Sika Samafil or visit our website www.sikacorp.com for further information. Warranty: As a Sika Samafil-supplied accessory, Aluminum Tape is included in Sika Samafil's Standard or System Warranty. Samafil® Maintenance: Aluminum Tape requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Technical Data: Adhesion to Backing Adhesion to Steel Adhesive Backing Elongation Tensile Break Temperature Range 36 oz./in width (39 N/100 mm) 75 oz./in width (81 N/100 mm) Rubber, 2 mil dead soft aluminum foil 11% 23 Ibsen width (403 N/100 mm) -20°F (-29°C) thru +150°F (66°C) Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.samafil@us.sika.com Canada Office Sika,Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer. The infomration, and, in particular, the recommendation relating to the application and end-use of Sika Samafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when property stored, handled and applied under normal conditions in accordance with Sika Samafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty In respect of merchantability of fitness fora particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Samafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concemed, copies of which will be supplied on request. CI • BASF The Chemical Company PRODUCT DATA 7 07 92 00 Joint Sealants Description NP 1" is a one -component, high- performance, nonpriming, gun -grade, elastomeric polyurethane sealant. It requires no mixing and typically requires no priming to bond to many materials, including concrete and masonry. Yield See page 3 for charts. Packaging 300 ml (10.1 fl oz) cartridges, 30 cartridges per carton 20 fl oz (590 mf) ProPaks, 20 per carton 2 gallons (7.6 L) pails; available on special order only For color availability in bulk packaging, call Customer Service. Color White, off-white, limestone, stone, tan, aluminum gray, hunter green, medium bronze, special bronze, redwood tan, tile red and black. Shelf Life Cartridges and ProPaks: 1 year when properly stored. Pails: 6 months when property stored. Storage Store in original, unopened containers away from heat and direct sunshine. Storing at elevated temperatures will reduce the shelf life. SONOLASTIC® NP 1 TM One -component, elastomeric, gun -grade polyurethane sealant Features Benefits • Readyto use Requires no mixing; reduces labor costs • Joint movement capability ±35% Provides excellent flexibility for keeping moving joints tight • Easy to gun and tool Speeds application .and makes neater joints • Available in cartridges, 20 ounce ProPaks, and in bulk Reduces jobsite waste, lowers disposal costs • Twelve standard colors Matches common substrates • No primer required for most construction materials Lowers installation costs r• Weather resistant Produces long-lasting weather -tight seals • Wide temperature -application range Suitable for all climates l• Compatible with nonrigid.coatings May be painted • Superior holding power Long-lasting roof file instalation • UL listed Passes 4 hour, 4 inch, fire and hose stream test when used with Ultra Biock•or mineral wool • Suitable for water immersion Documented performance in wet areas • Low VOC content Meets VOC requirements in all 50 states Where to Use APPUCAT1ON • Expansion joints • Curtain wall construction • Panel walls • Precast units • Aluminum and wood window frames • Roofing • Fascia • Parapets • Structural components • Vinyl siding • Wastewater treatment plants • Dams • Spillways and storm drains • Wetwells and manholes LOCATION • Interior and exterior • Above and below grade • Immersed in water SUBSTRATE • Concrete • Masonry • Aluminum • Wood • Clay & concrete roof tiles Sonnebor n SONNERORN• PRODUCT DATA NP 1" Technical Data Composition Sonolastic• NP 1" is a one -component moisture - curing polyurethane. Compliances • ASTM C 920, Type S, Grade NS, Class 35, Use NT, M, A, G, and l • Federal Specification TT -S- 00230C, Type II, Class A • Corps of Engineers CRD -C- 541, Type ll, Class A • Canadian Specification CAN/CGSB-19.13-M87, Classification MCG -2 -25 -A -N, No. 81026 • USDA compliant for use in meat and poultry areas • Underwriters Laboratories Inc .° classified (fire resistance only) • Canadian approval for use in establishments that handle food • SWR Institute validated • ISO 11600-F-25LM SEALANT•WATERPROOFING & RESTORATION INSTITUTE Issued to: BASF Brdlmng Systems Product Sone sstIc NP -1 C7,9: Pass ! Frt+35% Comp: -35% Substrata Aluminum, Mortar, Granite /twits and wants aamVabfOwI with pinta, N°. 79N 0661: Rating 25 Validation Bata 620/06 - 6/19/11 No.606-NP1611 Copyright 02006 SEALANT VALIDATION www.swrionline.org Typical Properties PROPERTY Service temperature range, ° F (° C) VALUE -40 to 180 (-40 to 82) Shrinkage None Test Data PROPERTY RESULTS TEST METHODS Movement capability, % ±35 ASTMC719 Tensile strength, psi (MPa) 350 (2.4) ASTM D 412 Tear strength, pli 50 ASTM D 1004 Utlimate elongation at break, % 800 ASTM D 412 Rheological, (sag In vertical displacement) at 120° F (49° C) No sag ASTM C 639 Exbudability, 3 seconds Passes ASTM C 603 Hardness, Shore A At standard conditions After heat aging (max Shore A: 50) 25 25 — 30 ASTM C 661 Weight Toss, after heat aging, % 3 ASTM C 792 Cracking and chalking, after heat aging None ASTM C 792 Tack -free time, hrs, (mwdmum 72 hrs) Passes ASTM C 679 Stain and color change Passes (no visible stain) ASTM C 510 Bond durability,* on glass, aluminum, and concrete Passes ±35% movement ASTM C 719 Adhesion* In peel, pli (min. 5 pl) 30 ASTM C 794 Adhesion* In peel after Passes UV radiation through glass (min. 5 pli) ASTM C 794 Artificial weathering, Xenon arc, 250 hours Passes ASTM C 793 Artificial weathering, Xenon arc, 3,000 hours No surface cracking ASTM G 26 Water immersion, 122' F (50° C) Passes 10 weeks with movement cycling ASTM C 1247 'Primed for water immersion dictated by ASTM C 920. Concrete and aluminum primed with 733; glass primed with 766. Test results are typical values obtained under laboratory conditions. Reasonable variations can be expected. SONN®ORW PRODUCT DATA NP 1 - Yield LINEAR FEET PER GALLON' JOINT DEPTH JOINT WIDTH (INCHES) (INCHES) 1/4 3/8 1/2 5/8 3/4 7/8 1/4 308 205 154 122 3/8 82 68 58 51 1/2 51 44 38 'One gallon equals approximately 12 cartridges or 6 ProPaks METERS PER LITER JOINT DEPTH JOINT WIDTH (MM) (MM) 6 10 13 16 19 22 25 6 24.8 16.5 12.4 9.8 10 6.6 5.5 4.7 4.1 13 4.1 3.5 3.0 How to Apply Joint Preparation 1. The number of Joints and the Joint width should be designed for a maximum of ±25% movement. 2. The depth of the sealant should be 1/2 the width of the joint. The maximum depth is 1/2" (13 mm) and the minimum is 1/4" (6 mm). Refer to Table 1. TABLE 1 Joint Width and Sealant Depth JOINT WIDTH, SEALANT DEPTH IN (MM) AT MIDPOINT, IN (MM) 1/4-1/2(6-13) 1/4 (6) 1/2-3/4(13-19) 1/4-3/8(6-10) 3/4-1 (19 — 25) 3/8-1/2(10-13) 1 — 1-1/2 (25 — 38) 1/2 (13) 3. In deep joints, the sealant depth must be controlled by Closed -Cell Backer -Rod or Soft Backer - Rod. Where the joint depth does not permit the use of backer -rod, a bondbreaker (polyethylene strip) must be used to prevent three-point bonding. 4. To maintain the recommended sealant depth, install backer -rod by compressing and rolling it into the joint channel without stretching it lengthwise. Closed -Cell Backer -Rod should be about 1/8" (3 mm) larger in diameter than the width of the joint to allow for compression. Soft Backer -Rod should be approximately 25% larger in diameter than the joint width. The sealant does not adhere to it, and no separate bondbreaker is required. Do not prime or puncture the backer -rod. Surface Preparation Surfaces must be structurally sound, fully cured, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, tar, paint, wax, rust, waterproofing or curing and parting compounds, and membrane materials. CONCRETE, STONE, AND OTHER MASONRY Clean by grinding, sandblasting, or wire brushing to expose a sound surface free of contamination and laitance. WOOD New and weathered wood must be clean and sound. Scrape away loose paint to bare wood. Any coating that cannot be removed must be tested to verify adhesion of sealant or to to determine an appropriate primer. METAL Remove scale, rust, and coatings from metal to expose a bright white surface. Remove protective coatings as well as any chemical residue or film. Aluminum window frames are frequently coated with a clear lacquer that must be removed before the application of NP 1'". Any coating that cannot be removed must be tested to verify adhesion of sealant or determine an appropriate primer. Remove any other protective coatings or finishes that could interfere with adhesion. Priming 1. NP 1" is generally considered a nonpriming sealant, but special circumstances or substrates may require a primer. It is the user's responsibility to check the adhesion of the cured sealant on typical test joints at the project site before and during application. Refer to product data sheet on Primer 733 or 766, and consult Technical Services for additional information. 2. For immersion applications, Primer 733 must be used. 3. Apply primer full strength with a brush or clean cloth. A light, uniform coating is sufficient for most surfaces. Porous surfaces require more primer; however, do not overapply: 4. Allow primer to dry before applying NP Depending on temperature and humidity, primer will be tack free in 15 —120 minutes. Priming and sealing must be done on the same work day. Application 1. NP 1'" comes ready to use. Apply by professional caulking gun. Do not open cartridges, sausages, or pails until preparatory work has been completed. 2. Fill joints from the deepest point to the surface by holding a properly sized nozzle against the back of the joint. 3. Dry tooling is recommended. DO NOT use soapy water when tooling. Tooling results in the correct bead shape, a neat joint, and maximum adhesion. 4. For roof tile applications apply a bead of Sonolastic® NP 1'" sufficient to make a bond between two tiles on the upper surface of the down slope tile. Install the upslope tile & press into the sealant bead to ensure good contact between the sealant and both tiles. SONNEBORN• PRODUCT DATA UPI" Clean Up 1. Immediately after use, clean equipment with Reducer 990 or xylene. Use proper precautions when handling solvents. 2. Remove cured sealant by cutting with a sharp -edged tool. 3. Remove thin films by abrading. Curing Time The cure of NP 1' varies with temperature and humidity. The following times assume 75° F (24° C), 50% relative humidity, and a joint 1/2" width by 1/4" depth (13 by 6 mm). Skins: ovemight or within 24 hours Functional: within 3 days Full cure: approximately 1 week Immersion service: 21 days For Best Performance • Do not allow uncured NP 1- to come into contact with alcohol -based materials or solvents. • Do not apply polyurethane sealants in the vicinity of uncured silicone sealants or uncured Sonolastic° 150 or 150 Tint Base. • NP 1"' should not come in contact with oil-based caulking, uncured silicone sealants, polysulfides, or fillers impregnated with oil, asphalt, or tar. • Protect unopened containers from heat and direct sunshine. • In cool or cold weather, store container at room temperature for at least 24 hours before using. • When NP 1' is to be used in areas subject to continuous water immersion, cure for 21 days at 70° F (23° C) and 50% relative humidity. Allow longer cure times at lower temperatures and humidities. Always used Primer 733. • Do not use in swimming pool or other submerged conditions where the sealant will be exposed to strong oxidizers. Avoid submerged conditions where water temperatures will exceed 120° F (50° C). • Do not apply over freshly treated wood; treated wood must have weathered for at least 6 months. • Substrates such as copper, stainless, and galvanized typically require the use of a primer; Primer 733 or 766 is acceptable. For Kynar 500 based coatings use Primer 733 only. An adhesion test is recommended for any other questionable substrate. • UV exposure may cause white NP 1' to discolor. This does not affect sealant performance; where maintaining a true white appearance is critical, use Ultra or Sonolastic° 150 sealants. • NP 1'" can be applied below freezing temperatures only if substrates are completely dry, free of moisture, and clean. Contact Technical Service for more information. • Lower temperatures and humidities will extend curing times. • Pursuant to accepted industry standards and practices, using rigid paints and/or coatings over flexible sealants can result in a loss of adhesion of the applied paint and/or coating, due to the potential movement of the sealant. However, should painting and/or coating be desired it is required that the applicator of the paint and/or coating conduct on-site testing to determine compatibility and adhesion. • Make certain the most current versions of product data sheet and MSDS are being used; call Customer Service (1-800-433-9517) to verify the most current versions. • Proper application is the responsibility of the user. Field visits by BASF personnel are for the purpose of making technical recommendations only and not for supervising or providing quality control on the jobsite. Health and Safety NP Warning NP 1- contains Stoddard solvent and crystalline quartz silica. Risks May cause skin, eye or respiratory irritation. May cause dermatitis and allergic responses. Potential skin and/or respiratory sensitizer. Ingestion may cause irritation. Reports associate repeated or prolonged occupational overexposure to solvents with permanent brain, nervous system, liver and kidney damage. INTENTIONAL MISUSE BY DELIBERATELY INHALING THE CONTENTS MAYBE HARMFUL OR FATAL. Precautions Keep container closed. Use only with adequate ventilation. Prevent contact with skin, eyes and clothing. Wash thoroughly after handling. Avoid breathing vapors. DO NOT take intemally. Use impervious gloves, eye protection and if the TLV is exceeded or used in a poorly ventilated area, use NIOSWMSHA approved respiratory protection in accordance with applicable Federal, state and local regulations. First Aid In case of eye contact, flush thoroughly with water for at least 15 minutes. SEEK IMMEDIATE MEDICAL ATTENTION. In case of skin contact, wash affected areas with soap and water. If irritation persists, SEEK MEDICAL ATTENTION. Remove and wash contaminated clothing. If inhalation causes physical discomfort, remove to fresh air. If discomfort persists or any breathing difficulty occurs or if swallowed, SEEK IMMEDIATE MEDICAL ATTENTION. Refer to Material Safety Data Sheet (MSDS) for further Information. Proposition 65 This product contains materials listed by the State of Califomia as known to cause cancer, birth defects and other reproductive harm. VOC Content NP 1' contains 43 g/L or 0.36 lbs/gal, less water and exempt solvents. For medical emergencies only, call ChemTrec (1-800-424-9300). BASF Construction Chemicals, LLC — Bullding Systems 889 Valley Park Drive Shakopee, MN, 55379 www.BuildingSystems.BASF.com Customer Service 800-433-9517 �t Technical Service 800-243-6739 10.01® WAHBANIY NOTICE Every reasonable effort is made to appy BASF erecting standards both In the mmMecCrte of our pmoWds and in the information which we issue concerning Mese products and the use. We warrent our products to be of good godly ad w0 remote a, at our election, refund the purchase trice of wry products pored detadNe. SaOsfastory mulls depend not only Won welly metals, but ado Won marry lectors ba,erd as coned. Therefore, swept for such replacement or refund, BASF MAKES NO WARRANTY OR GUARANTEE, IDPRESS OR RAKED, OICLUDNG WPAHWITIFS OF 0810SS FORA PARTICULAR PU10ag OR M91C1NNTABIINY, RESPEC11NG ITS PRODUCTS, end BASF shad hare no other da8Ottywth respect thereto. My ddm regedhp product defect must be reseed h wtlOng within one (1) year from to date 0 ahmm eM. Pio shim x111 be laddered without such written notice a alter Ole spaded tine Interval User Shen determine the eiaUSOy 0 the produces for the Intended use end aware all des end dabdiy In connection therewith Any authorized change In the printed rewmmenda8os concerning to use of ore weeds mud hearth signature of The BASF Technical Manager. 116 trtamatlon end di hatter mdrice ad8ce are based on BASF0 present loweedge end apednco. Hower, BASF assumes no Iabdly for poVd g such informal* end mute Inching to aslant a Worn such bdamal* and advice may reds to edging thed parry interlace/al popery dgbts, especially patent rights. a padkudd BASF diadems ad CONDMONSPM) WARMNOES,WHETHER RPRESS OR PAM), NCllr)INGTHE RIVED WARRANTIES OF FIT 8ESS FORA PAROCUA0R PURPOSE OR MERCFWJIABMP BASF SHAH NOT 88 RESPONSIBLE FOR CONSEOUHIML, NDRECT OR NCIOB10AL DAMAGES 588110NG LOSS OF PROM) OF ANY 0180. BASF resales the fight to maim erry charges eaa0mg a tedhalaphsl pogmss a Why( degelLementt t is the Batons resp reggh and &dgaen to =NW treed end test any bcanbg goods. Pafmrmes 0 the pode(s) Nonmed herein ahoud beverified by testing end awed out mgbywaged apes. td thwd resyoslrolp' Ogle customer tomay out and arrange for any such WON. Reference to trade names used byother vanpenes Is nether a rearnmerheion, nor an a Base ant of any pradact and does not imply the sale products could not be used. Foran No. 1017906 10/08 ® 2008 BASF For professional use only. Not for sale to or use by the general public. Printed on recycled paper 00101ng 10% post -consumer fiber. Printed In USA 1 � D g8 71 HINGE SIDE 2'-6" FRAME OPENING [762] [1162] 7 O Z z 11V a3AO MIA 01a3WOSI • PI CO cn m WOO'OOmMM Z1 N C 11-02-16 THE BILCO COMPANY d3H SJ7VS O 59 •''J/3!10197.7 ROOF SCUTTLE NOT /NCLUOED Z 0Dm D ('lm V l =m (Dit m N m O O N Z VI O Z y ' y .Z] m ml Z r W (Cil D (n r n N 0 -1 „r2 mm( m y O n z Dm C C m 0 0 c O rr- l � z O 11V0 WfNIWl1V 1SVO '9 (P A CA 0 D 0 Z Z m J N co • D m O m x r y N m Z D 0 -y = = z N D z cn N m -o Z SINOddflS 1SOd WfNR fl1V '£ N M 0 O x D z O m 0 O C D m m 0 v z 0 D SNO/16',7/J/)JdS J 11. VersaMount® Replacement Hatch - Detail information for VersaMount® Replacement H... Page 1 of 2 HOME ABOUT BILCO OUR PRODUCTS COMMERCIAL Natural Ventilators Smoke a Fire Curbdre Roof Hatches Monadic Smoke Veab Floor Access Doors _ . fistety Pmclucts Bans:yds Door Locks _____.._ ..... RESIDENTIAL Blico Basement Doors Egress Wdcw WeSe PermEnty Erdrence Contractor Programs Tustin:Mats . Login I RehtsrJ My Account I Shope The Worldwide Source for Specialty Access Products CONTACT US CUSTOMER SERVICE ORDER PARTS TRADE SHOWS PFtEd Versahlountilb Replacement Hatch The Versakficamt replacentara hatch afiows you to replace a damaged mof hatoh wehout re-roolirg. Simply remove the cover from the damaged *di and plater the Yawn:ant hatch on top of the oxidate curb. The lowydriln VersaMount curb fealurea 5 tuet-in flange and apron and Innovative anchor orm syskun to ensure fast, sasum, and vniathenighl Installation Ausdablo in a number of standard Pea riesallf0en Rep reldsrumants Roof Hatch Models: S-20VM, N13.20VM, L-20VM, EW-2DVM, S-50VM, NB -50V1 L-5OVM, EW-50VM Standard Features and Benefits • Buthin apron simpfrftes Installation on existing curbs and ensures watertightness • Engineered with compression spring operators to provide smooth, easy, one -hand operation, regardless of size • Automatic hold -open ami laces the cover in the open position to ensure sate egress • Overlapping cover design, full voided comers on cover ' and cult, EPDM rubber gavial* and fully Insulated cover and curb ensure weethertightness and energy efficiency • Constructed wfth corrosion reafstent materials to provide many years of trouble free, dependable service • Heavy gauge construction end positive latching mechanism maintain building security • Avaliatde In many sizes and curb configurations to satisfy any requIremeM or installation Guide Specifications • Material (select one): Meet Cover and frame are 14 gaup (2 rnm) 0-90 paint bend gatvenized sleet Aluminum! Cover and frame are 11 pup (2.8 nun) alundnum f3takdass Sleet Cover and frame .10 14 pugs (2 mm) type 304 steintess sleet • Cover Brakefonned, hollow -metal design with 1" (25 mm) concealed tea Insulation, 3" (76 mm) beaded, overlapping flange, fugy welded at comers, end Internally reinforced for 40 psf (196 kgMt We load, • Curb: 4. (102111110 hi tedght breakformed hollow -metal design Wei 1" (25 mm) concealed fiberglass Insulation, 2-518" (07 mm) mounting flange and 1.112' (38 nen) amen Italy welded at comers. Ellairdass steel anchor filps are included. • Gasket Edruded EPDM rubber gasket permanently adhered to the coven • Magas: Needy -duty pingo hinges ath 3 fir (9 min) type 31e Wafflings steel hirde pins. • Latdc Shun latch vat intedor and exterior turn hinges end padlock hasp • Lift Assistance: Compression spring actinide:a enclosed In telescopic tubes. Automatic hold -open arm ME grip handle • Mnlah: Steel: Alkyd base red ordie primer. Aluminum: MIS Finish. Stainless steel: Type 304 stainless steel YAM bead Mast en% • Hardware: Steel: Engineered composite compression spring tubes and steel compression springs packed in grease. All other hardware is zinc platmlferromate sealed Aluminum: Engineered composite compression spring tubes and steel compression springs packed In grease. Type 319- Stainless steel hinges. All other hardware Is zinc plated/chromate sealed, U.6. Patents 6,347,816 5,672,020 Now Available In Ensergy- efildent Thermally Broken Design Click here for more information Forge oPeranilWiittaitrb-' „built curb and Versamount roof hejfe_tf.- morrows Body Mouths on new or existing concrete curbs SEARCH 01 keywordoor SEAR, SALES CDNTA WARRANTY SE DOWNLOAD Submits! D CAD de GM Mtn Specifics Installs:ion In Ulan& Find us • i C 09-M3 f h1AOZ-M3 Pr: al 14. 11/1 44404 mgi 10% ig 1144 Ce = C/) rn0 Z C E FRAME OPENING 1 DTH + -11 1/8 [413mm] MAME OPENING W'.OTH r 1 .i.ii0 li!X11'i[i!i!dl9ldl!i'i!i!Oililili!t!li!:.ii (} 1 Pili./I. A _ ' %eFL 1,44 1lamo Iyiryi!l eettlITeiliiiWniAl! eaeg iiiWiTOeitsY410116 e tTIN -x Z 4 G1 m r m r m 441 rn�o $//nom� W C rri � 1 r • • F?' mg' a rig irrag o9 .z{ rzr q P1 rn �n f Z = yp l -f �77 Vi 9 >=M2 C l R gA Y iA s g 5 O 8D 4,,,% acrd m o= 3? r d :-lager * • a �zvxg�lo'�'n�Nll ,Im yc � • D1c m..-..,mr.2mm-11g=ck r4E0c[�lo''>>�=oo1E yl, $ g a'< N; y> I I A r r l y l r j in In E 8 sCy � azo c �f �Q� � x �zn Y� ac c0 c 0 gg.(o7 �O{.. �^I rr x �+ O C Z RR 44 p mm 0 %XE IR' i D D Cm m A AY o'1FPi ��vm g Or' N Z to v mi5 FII £0:3 01 P. A W N+ p M m V 01 p. A W N tzt tl P 1 A V x 3 $ 0 CD O q cn 0) O F SNOLLVDIJIJ3dS 01 cn O W 0 0 8 z3 cz 3p mm 2 f, z tn 0 x z 0 m rn v 0 0 m 0 0 0 0 Cr‘ CO 0 me 0 NICh M AcG �z rnc SNOISN3WI0 92U13 34ISNI .96 X ebb 9NR1dS NOISN31 )INTI 3l9ISfl3 W3/lfl 0 0 U 3 =n=om Z2 35 3�rrti rni 51 nil 0 1-71 '7' 153 c> 0> 0- 03 �i m< C = m = i r N 111 �� vrn rn �m � ,O my m 0 m 3SV3132d 1df1NVW rn 70 7o co n Otn O -I C z� 0- 3 G° O6) rn D = D rn 17! N rn rn� Orn 1 m mm z ego TIMIM aum -0 � rnm a a en bd-868bF1 z 30 °Drn mm 3m ma zrn 4 02 om te A v G D .7 gMQM v 1-! 'wz Mo = vex 1 pnp r O tzt soms m^ C ;g$ N y w zp Cz Syr z 1:07 gz T ENERGY STAR FIBERLITE CURB MOUNTED SKYLIGHT w w �SN m2XcJ ON m<z� irnmo�aD Mill Q° 8a� m-42 1 z rn C ma Oz my rn 1 • Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com WAVNIi'S HOOFING, 1VVh 11 LI 11_` 1U.II SUMNER, WA CERTIFICATIONS 3 ' F FU.R8992 - Roofing Systems Page 2 of 49 25 PSI CG", "SarnathermM AGF", "SarnathermM 25 PSI AGF" or Johns Manville "ENRGY 3", in any of the following Classifications. One-half in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this Is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board or oveHayment board are offset 6 in. with the joints in the deck. If polystyrene insulation is used in the existing noncombustible deck Classification, it must be placed beneath the gypsum board or DensDeck®. Any system listed for use over a combustible deck can be installed over a non-combustible deck and achieve the same classification. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. Unless otherwise indicated, on non-combustible decks, Sika Samafil Inc. "Sarnatherm Roofboard H" or "Samatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite" may replace, or be used in addition to, any Sika Sarnafll Inc. Sarnatherm product or Hunter Panels H -Shield product or any UL Classified wood fiberboard, in any UL Classified insulated roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 If Sika Samafll Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite" is used directly below TPO membrane. Unless otherwise indicated, on combustible decks, Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Samatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite", may be used in addition to any Sika Samafll Inc. Sarnatherm or Hunter Panels H -Shield product or any UL Classified wood fiber board, in any insulated UL Classified roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 if Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD"or "H -Shield HD Composite" is used directly below TPO membrane. Sika Sarnafll Inc. "Samatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite"" may be used over any UL Classified polystyrene on non-combustible decks. Max incline shall be in accordance with the Classification established for the insulation/membrane roofing system, but cannot exceed 2:12. "Sarnacol 2170R" is an acceptable alternate to "Sarno! 2170". "SPL -45" is an acceptable altemate to "Sikaplan 45" In all applicable Classifications. "SPL -60" is an acceptable altemate to "Sikaplan 60" in all applicable Classifications. For Combustible Decks - Class A: 1. A minimum 3 in. layer or a minimum two layers of 1.5 in. of Sika Samafil Inc, "Sarnatherm Composite Roofboard H" or Hun Panels, "H -Shield HD Composite" is placed directly over a combustible deck and is covered with any UL Classified roofin • brane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classifi - • sulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3 in. um total thickness of Sika Sarnafll Inc. "Samatherm Composite Roofboard H" or Hunter Panels "H -Shield HD Composit-" e insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrl - on -UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from . - .eck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classiflcat'• stablished for the membrane/insulation roofing assembly, however the Incline cannot exceed 1/2:12. 2. A minimum 1.9 In. layer of Sika Samafil Inc. "Sam. Composite Roofboard H or Hunter Panels "H -Shield HD Composite" Is placed over a minimum 1 layer of Carlisle "FR : • = - heet 1S" or Elk "VersaShield FB -1S" over a combustible deck. The insulation is covered with any UL Classified roofing •rane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified i. . ion (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9 in. min' total thickness of Sika Samafil Inc. "Sarnatherm Composite Roofboard H" or Hunter Panels "H - Shield HD Composi -". e insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barr' - on -UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from • - . eck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification blished for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. 3. A minimum 1/2 in. layer of Sika Sarnafll Inc. "Sarnatherm Roofboard H", over a minimum 2.5 in. layer of any Sika Sarnafil Inc or Hunter Panels Classified polyisocyanurate Insulation Is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. uccd bclow the 3 inminimum total thicknPcc The Insulation may be loosely laid or attached with fasteners and plates, hotrseflag— •..* - - -- - - _ - _ Il insulation joints must be staggered a minimum of 6 in. from the deck joints or from the Insulation joints directly below. The maximum incline shall be In accordance with the Classification established for the membrane/insulation roofing assembly, however the incline can not exceed 1_u-_-//1_a_L_____1 _____/___ t KTC7T T1___1_T Tf1T7VT/1 TT AL KT!/_L ___W _ A/'1 /'1 r 'T0FU.R8992 - Roofing Systems 1/2:12. Page 3 of 49 4. A minimum 1/2 in. layer of Sika Sarnafil Inc. "Samatherm Roofboard H", or Hunter Panels "H -Shield HD" over a minimum 1.4 in. yer of any Sika Sarnafil Inc or Hunter Panels Classified polyisocyanurate insulation is placed over a minimum 1 layer of Carlisle "FR B e Sheet 1S" or Elk "VersaShield FB -1S" over a combustible deck. The insulation is covered with any UL Classified roofing me brane used In any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified Insul ion (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9 in. minimum total th kness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor ba 'er (non -UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from the d k joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established • the membrane/insulation roofing assembly, however the incline can not exceed 1/2:12. 1. A minimum 1/ 'n. thick layer of "Invinsa FR" is placed directly over a combustible deck (minimum 15/32 in. plywood) and is covered with any U Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an altemative, SIKA RNAFIL INC "SamathermM CG", "SarnathermM 25 PSI CG", "SarnathermM AGF", "SarnathermM 25 PSI AGF" or Johns Manville "ENRLY 3", any thickness, may be used below the 1/4 in. minimum thickness of "Invinsa FR". All insulation joints must be staggered a. min • um of 6 in. from the deck joints and from the insulation joints directly below. The maximum incline shall be In accordance with the . ssification established for the membrane/Insulation(s) roofing assembly as listed In UL's Roofing Materials & Systems Directo • however the incline cannot exceed 3:12. 2. A minimum 1 in. thick layer of NRGY 3 FR" Is placed directly over a combustible deck (minimum 15/32 in. plywood) and Is covered with any UL Classified roofi membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, SIKA SARNAFIL INC " mathermM CG", "SarnathermM 25 PSI CG", "SarnathermM AGF", "SamathermM 25 PSI AGF" or Johns Manville "ENRGY 3", any thick -ss, may be used below the 1 in. minimum thickness of "ENRGY 3 FR". All insulation joints must be staggered a minimum of 6 in. fro • the deck joints and from the insulation joints directly below. The maximum incline shall be in accordance with the Classification est• • lished for the membrane/insulation(s) roofing assembly as listed In UL's Roofing Materials & Systems Directory; however the i cline cannot exceed 3:12 For Combustible Decks - Class B: 1. A minimum 1.9 in. layer of Sika Sarnafil Inc. "Sarna Composite" is placed directly over a combustible deck an B roofing assembly to achieve a Class B fire Classification. extruded polystyrene), any combination, any thickness, may or Hunter Panels. The Insulation may be loosely laid or attache vapor barrier (non -UL classified) may also be used below the Ins from the deck joints or from the insulation joints directly below. Th established for the membrane/insulation roofing assembly, however erm Composite Roofboard H" or Hunter Panels "H -Shield -CG", "H -Shield HD is covered with any UL Classified roofing membrane used in any UL Class an altemative, any UL Classified insulation (except expanded or e used below the 1.9 in. minimum thickness layer of Sika Samafil Inc with fasteners and plates, hot roofing asphalt or cold adhesive. A ation. All Insulation joints must be staggered a minimum of 6 in. maximum incline shall be in accordance with the Classification e incline can not exceed 1/2:12. 2. A minimum 1/2 in. layer of Sika Sarnafil Inc. "Sarnatherm Roofboard in. layer of any Sika Sarnafil Inc or Hunter Panels Classified polylsocyanura and is covered with any UL Classified roofing membrane used in any UL Cias Classification. As an alternative, any UL Classified insulation (except expanded thickness, may be used below the 1.9 in. minimum thickness layer. The insulatio and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non -UL classified insulation joints must be staggered a minimum of 6 in. from the deck joints or from maximum incline shall be in accordance with the Classification established for the me the Incline can not exceed 1/2:12. or Hunter Panels "H -Shield. HD" over a minimum of 1.4 insulation is placed directly over a combustible deck roofing assembly to achieve a Class B fire extruded polystyrene), any combination, any may be loosely laid or attached with fasteners ay also be used below the insulation. All e insulation joints directly below. The ane/Insulation roofing assembly, however 1. Deck: NC FLUID APPLIED COATING SYSTEMS Class A Incline: 2 Surfacing: — "Sikacoat", applied in two or more coats, for a total of 2 to 5 gal/sq. May be reinforce (3 oz/sq yd max). 2. Deck: NC Incline: 2 Surfacing: — "Sikacoat", 6 to 12 gal/sq, reinforced with polyester fabric (3 oz/sq/yd max). 3. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified, any thickness, mechanically fastened. Barrier Board: — G -P Gypsum DensDeck®, 1/4 in. thick, mechanically fastened. ith polyester fabric World Class Roofing and Waterproofing Wavne's Roofing, Inc. Approved as Sika Sarnafil Elite Roofing Contractor Sumner, WA - January 2012 — Sika Sarnafil has approved Wayne's Roofing, Inc. as an Elite level roofing contractor for installation of Sika Samafil roofing systems. The company is one of just 146 Sika Samafil Elite roofing contractors in the United States to be selected in recognition of their commitment to high quality roofing installations. Every Sika Sarnafil approved contractor goes through a rigorous training and evaluation program to assure that they meet Sika Sarnaifl's high standards. In addition, each contractor is evaluated and rated annually on a variety of technical and business criteria and classified into one of three categories — Elite, Alliance and General — with Elite being the highest level of achievement. "We are pleased to recognize Wayne's Roofing, Inc. as a Sika Sarnafil Elite Roofing contractor," said Brian Whelan, senior vice president of Sika Samafil. "Elite level roofing contractors are the best in the business, having demonstrated an unparalleled commitment to quality and the roofing industry." For information on the roofing services of Wayne's Roofing, Inc., call 253-863-4455. Sika Sarnafil has almost 50 years of experience in providing thermoplastic, single ply membranes for a wide range of roofing and plaza deck waterproofing applications. The company is known for its high quality, long lasting membranes and systems that help building owners achieve a sustainable roofing solution. Sika Samafil is a division of Sika Corporation. Visit the Sika Sarnafil website at usa.sarnafl.sika.com. Sika Samafil, A Division of Slka Corporation, 100 Dan Road, Canton, MA 02021 Tel. 800-451-2504, Fax: 781-828-5365, www.sikacorp.com Sarnafil® March 2, 2017 Company: Re: Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Approved Applicator Status Project: Gateway North Building 5 Tukwila, WA To Whom It May Concern: Samc'alfil. BUILDING TRUST This letter is to certify that Wayne's Roofing, Inc. is an approved and qualified applicator of Sarnafil roofing and waterproofing systems in good standing. Certified since 2004, Wayne's qualifies for all available roofing and waterproofing warranties offered by Sika Corporation • Roofing. Wayne's Roofing, Inc. has earned the status of Partners Club Elite Applicator, our highest overall rating relative to quality installations, technical expertise, payment history and integrity. If you have any questions, please contact our office. Regards, Kara Sanders Sika Corporation • Roofing SIKA CORPORATION • ROOFING 6590 Darin Way, Cypress, CA 90630 Tel: 714-898-9355 • Fax: 714-898-9357 • usa.sarnafil.sika.com tre Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com WAYNEE'S HOOFING, INC. --sa.H F/2.," SUMNER, WA WARRANTIES 4 20 Year S Warranty Serial No.: SAMPLE {/�• B G TRUST stem . s arr SIKAPLAN ROOFING WARRANTY FOR COMMERCIAL BUILDING Building Owner: SAMPLE Building Name: SAMPLE Building Address: SAMPLE Applicator: SAMPLE Date of Substantial Completion: SAMPLE Building/Area Name: SAMPLE Used As: SAMPLE my e of Inspection: SAMPLE Sika Corporation ("Sika"), warrants to the owner of the bui the limitations set forth in section 10 below, stated herein, Sika Corp Sarnatherm Insulation or Sika Corporation Roofing Acceslories installed accor Authorized Roofing Applicator for a period of twenty) years co ing with the date Membrane with no monetary limit with res• ct to roof repair costs. Area Warrantee. Telephon : SAMPLE MPLE sq. ft. rlbed above ("Owner"), that subject to t - conditions, and limita • will repair roof leaks originating from the Sikaplan Roof ika Corporation's Technical instructions by a antial completion of the installati TERMS, CONDITIONS, LIMITATIONS 1. Owner shall notify Sika Corporation writing within one week. 2. If on Sika Corporation's inspection Insulation or Accessory provided b n the first busine Sika Corporation Sika Corporation to the ay imm ions, including g Membrane, ka Corporation of the Roofing tely following the d covery of each leak in the Roofing System and confirm in termines that the atorfor eak is caused by . defect in the Sikaplan Roofing Membrane, Sarnatherm his building or fro a defect in the Sika Corporation Authorized Applicator's workmanship applied to that Sika • Ian Membrane, except as provi • e• ' he following par.: raph three (3) Owner's remedies and Sika Corporation's liability shall be limited to Sika C. • . ration's repair of the Roofing Membrane, Sarnather Insulation or Accessory. 3. This warranty does not apply and may • . nd void if any of the following occur: The Roofing Membrane, Sarnatherm Insulatio a cessory is damaged by a natural disaster I , but not limited) to, earthquake, lightning, hail, peak wind gust in ex • • 60 mph, hurricane, or • •o as defined by The National Weather Se = • r other acts of God, or: (b) The Roofing Membrane, arnather ation or Accessory is da . _ - • by any act of negligence, accident, or misu cluding, but not limited to, (a) (c) (d) (e) (f) vandalism, falling obje of war, or: A deficient pre-existing Metal work or other a • There are any alterati. are placed on or attac = • �z Failure by the Owner or his including that of sealants and cau (g) Loss of integrity of the building envelope . . windows, doors or ether envelope components (h) Condensation ac (1) A significant cha installed, or: (j) The Roofing M: (k) Deficient desi:. (I) The Owner fai 4. During the period of 5. Should the Roofing M civil disobedience, ondition or equipment is caus essories or equipment is used in the s or repairs made on or through the co to the completed • - hout first to use reasonable or: er entry, or Roo : - • d causes leaks, or: mpletedroo,• ectssuch asbut not lim -. • res, equipment, or structures obtaining writt en aut rn from Sika Corporation, or: intaining the roof as described In : • ner's Guide provided with this warranty, or structure incl m roof damage b mulates-ssembly due to . • rrect design or due e in the use of the building • • - - see expected by I but d • •• ited to partial or complete or: I' - .•orb. blown r or reduction rporation to e brane is damaged b contaminates and/or spills, or: applied to the Roofing ; - •.. . • ch as membrane contact with Incompatible materia o comply with every term and c. . • - . this ty, Sika Corporation, its agents a - u • Membrane be c• . ed, the cost of exposure of the • • . • - . i ns loyees, repair, such as removal and replacement o a 6. Sika Corporation shall have no obligation under this war the Sika Corporation Authorized Applicator have been paid for in 7. Sika Corporation's failure at any time to enforce any of the terms or condi 8. This warranty - . sferred to a subsequent Owner of the Building If approve process the t : nsfer and to insp a • - • . . r • oration Roofing System, If necessary, access to the r Membrane for purp ing or overburden, shall be the responsibility. ntil all invoices for materials, in ted herein shall vance overburden,. 9. The Owner way, direc Corporati System, shall fir I •' • ;mediation • - designated by the Am In the abse American Arbitration Assoc . • nstru • in Boston, Massachusetts. This enforced in accordance with, the laws 10. THIS WARRANTY IS GIVEN IN LIEU OF ALL FITNESS FOR A PARTICULAR PURPOSE. THERE AR s STATED HEREIN ARE EXCLUSIVE REMEDIES AND SIKA C INCID - DAMAGES DING THEPRESENCE OFMO • , W TSOEVER,INCLUDINGB T NOT UMITED TO, DAMAGE TO TH THE CONTENTS THEREO LOSS OF USE O •- = • ING OR ANY C ERSONS. SAMPLE Authorized Sign hall be the Owner's responsibility. nd Sika Corporation hereby agree that any and all claims (contractual, statutory, or indirectly, arise out of or relate to this Warranty, or the alleged breach .rthe alleged breach. submitted to non -b an Arbitration Associa ' • n in accordance with t anty, and any claims, e Commonwealth of Massachusetts. ER WARRANTIES, EXPRESS OR I WARRANTIES THAT EXTEN RATION SHALL NOT BE GI, BACTERIA, LDING ON ONE ss of roof decking, wall siding, rrier effectiveness, or: he Roofing Membrane as originally and/or substrates, or: of during regular business hours. ka Corporation's investigation and/or n, and services provided by Sika Corporation and not be and in sb • nstrued to be a waiver of such provision. riting by Sika Corporation and the cost to not limited to, removal and replacement of co w or otherwise), disputes, or suits that in any thereof, ort. any contracts between the owner and Sika installa n, and/or inspection of the Sikaplan Roofing jointly selected b the parties or, in theabsence of agreement, as on, all ch claims shall be settled by arbitration by the ion Rules. Any such mediation and/orarbitratlon shall take place n the parties hereto shall be governed by, and construed and the design, manufacture, sale, distribution, eutral mediator j e of resolution by ion Industry Arbitr es or sults betw PLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR BEYOND THE DESCRIPTION ON THE FACE HEREOF. THE REMEDIES R•NSIBLEORUABLEFOR ANYINDIRECT, CONSEQUENTIAL OR SPORES,•TOXINS ORTHE UKEORFURTHER LOSS OFANY KIND WHICH THE OMPONENTSOFTHEROOFARESITUATED,DAMAGE NT PART EREOF, OR DAMAGE TO ANY OTHER PROPERTY OR NO RE"ESENTATIVE OF • CORPORATION HAS AUTHORITY TO MAKE A EPRESENTAT • NS OR PROMISES EXCEPT AS STATED HEREIN. is Warranty Is Effective Fr •• SAMPLE throu e(1): AMPLE e: SIKA CORPORATION • ROOFING 100 Dan Road • Canton, MA 02021 Tel: 781-828-5400 • Fax: 781-828-5365 • usa.sarnafll.slka.com SA SAMPLE PLE Aut • rized Signature(2): SAMPLE Date: i ■ ■ Roo Whereas WAYNE'S herein called "the Contractor," h Owner: Address of Owner: Type and Name of Building: Location Area of Roof Date of Completion: Date Guarantee Expires: Whereas, at the inceptio materials or workmanship for a limite Now, Therefore, period of Five_(_ .5__) years from t made such repairs to said roof and applied by or through the Contractor This guarantee is made subject to the 1. Specifically excluded from this g omissions of other trades foundation settlement; i] roof is applied, fault building; vapor cond of the foregoing this damage is repaired b 2. The . , actor is no • 3. 8. In positi o work s races, raili roof, unless recommend re this co re o en flashin all be d g, platf the Co ions guar tions 1. '1 is g ntee sha s ch u e was origi c vered by this gu This gu..ntee s accordanc with t This guaran ee s workmanshi an This guarant: e is Additional c ndi itness Where f, • ur co or cti en cons sation guarant the Con liable fo ne rms tract th r ee rep 1 be ally ant•• 11 s ra c n sai r oth shal ect �11 an occ e nul cifie r • • or e ag - - • nt pi 11 b:, 'me null provided an op n lieu of all oth ions or exclusioi is instrument h • • n ing Guaranteefl4IP tOOFING, INCORPORATED, of Sumner, Washington, s completed application of the following roof SAMPLE WARRANTY as folio ,,,,„_ Lit'X n of 1 period he Contractor 'e date •ompos m. uar. tract crack on o each d hall i ;tor a rose • •oof, equi be fist ;reto, void. ;ione and and co t sua d p rtu e gu:rant n : rs e: such and of on be ing cond tee is rs; rs; light ng of par e ro ere the uent nclu :me no and by i oid he see e e t to void ity t n du work the Co subject heresy . .leti.n of 'shin • resulti nee:ssar �to do .: an an al ing wi , th • ro r f H pet w. 1, c • f; r e - tra l •on+e o 1 pe s: of 1e ! I da : ge • ng, • t i lastJed r• ued,Isha ch r- co , e Con la • work o others f he roo is ificatin e• ive It, le:s h h su.l roof un ess t e C • i spect the es •r w. anties, y e ecuted this tr the c Guar••nte?s, saii main dam dsto k; d ping., • ns null pa • thi hout •r se re gi end. or • used s no ani ontr- . • f. cto rndttions roc g solely ain ge , fec chimneys, • r p and request bui lim on en ion> all on : as E ed in urti Is a ctor express day - agreed he su f, it w' said r -o sai • hailstorm, s or failure tch boxes; void ding or tation, the roof, the opportunity are complied be raid aid roof. promenade parEgraph a plied. is promptly or of , to gua : 'n set 'ect o the 11, a its o om ault of ' wat oof, th or o her of sky ghts, fire. for e balanca g such repairs. contents work in and no to with. for time or work 8 below. Contractor notified implied 200X an'ee ort/, conditions n or might building aterial I resulting connection repairs crake has the : cost and defecis coniition. or .musual; used vents, 'the r of the or F ure and deck Areas been of the aforesaid herein set expense, in materials contents phens as -roof s •ports, of is damaged guarantee from any wit ues, al ations necessary to observe material or is sprayed that pond paid in alleged make cEused ena base or de shall expended full defect roof agai forth, or or by of the over other by reqs perio ' cts in vents, be roofing this condition or flooded, water for in t faulty 'hat during cause or anship the acts elemen which parts the of any nless such said roof drains, sign made to said application shall in making unless shall not said roof materials a oe or s; le or be in or BY WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD r—SUMNER,.WASHIN.GTON 983VA„,../. AC. (253) 863Q445VSEA 21(�6S`5 Sr0.O7 AUTHORIZED REPRESENTATIVE Donald Guthrie, President ■ ■ QERMIT COORS COPY � PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0085 DATE: 04/11/17 PROJECT NAME: GATEWAY NORTH BUILDING 5 SITE ADDRESS: 3415 S 116 ST X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AU) `'---\-17 utlding Division II Public Works AYA-- 4-13-17 Fire Prevention Structural Planning Division ❑ Permit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/13/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/11/17 Approved Corrections Required ❑ Approved with Conditions aV ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 WAYNE'S ROOFING INC 0 Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries a Search L&I A -Z Index Ilelp Page 1 of 4 My I.t&I Workplace Rights Trades & Licensing WAYNE'S ROOFING INC Owner or tradesperson Principals GUTHRIE, DONALD D, PRESIDENT WETHERBEE, RODNEY ALLEN, VICE PRESIDENT JOHNSON, DANIEL JON, VICE PRESIDENT WETHERBEE, KITTY, SECRETARY BULTER, BRIAN LEE, SECRETARY ANDERSON, JEANNE COLETTE, TREASURER WETHERBEE, WAYNE W, PRESIDENT (End: 04/30/2007) MANN, SHARON R, SECRETARY (End: 04/30/2007) Doing business as WAYNE'S ROOFING INC WA UBI No. 600 178 144 13105 HOUSTON RD SUMNER, WA 98390 253-863-4455 PIERCE County Business type Corporation Governing persons DONALD GUTHRIE RODNEY WETHERBEE; SHARON MANN; KITTY WETHERBEE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .............._......................................................... Meets current requirements. License specialties GENERAL License no. WAYNESR205Q5 Effective — expiration 11/25/1980— 05/02/2019 Bond ........_....... THE HANOVER INS CO Bond account no. 1968027 Received by L&I 04/11/2011 $12,000.00 Effective date 04/13/2011 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600178144&LIC=WAYNESR205Q5&SAW= 4/24/2017 WAYNE'S ROOFING INC Until Canceled Insurance ............................... Continental Cas Co $1,000,000.00 Policy no. 6024454961 Received by L&I Effective date 04/18/2017 05/01/2017 Expiration date 05/01/2018 Valley Forge Ins Co $1,000,000.00 Policy no. 6024454961 Received by L&I Effective date 04/29/2016 05/01/2016 Expiration date 05/01/2017 Insurance history Savings ......... _.......... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 278,110-00 Doing business as WAYNES ROOFING INC Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T3 / STEPHANIE HENDERSON (360)902-5598 - Email: HSTE235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 12/13/2016 Inspection no. 317943110 Location 409 W WALNUT ST Centralia, WA 98531 Inspection results date 05/24/2016 Inspection no. 317940339 Location 5010 Pacific Ave N Tacoma, WA 98408 Inspection results date No violations No violations Page 2 of 4 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600178144&LIC=WAYNESR205Q5&SAW= 4/24/2017