Loading...
HomeMy WebLinkAboutPermit D17-0148 - US ARMY RECRUITING OFFICE - INTERIOR IMPROVEMENTUS ARMY RECRUITING OFFICE 666 STRANDER BLVD D17-0148 Parcel No: Address: 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0005800037 Permit Number: D17-0148 666 STRANDER BLVD Project Name: US ARMY RECRUITING OFFICE Issue Date: 6/21/2017 Permit Expires On: 12/18/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BC PARTNERS LLC PO BOX 997 C/O MK PROPERTY SERVICES LLC, SNOQUALMIE, WA, 98065 SAM MORRIS Phone: (425) 281-1632 700 NW GILMAN BLVD - SUITE 351, ISSAQUAH, WA, 98027 ENRICHED DESIGNS INC Phone: (425) 255-5467 12920 SE 95TH WAY, NEWCASTLE, WA, 98056 ENRICDI12809 Expiration Date: 7/3/2017 MK PROPERTY SERVICES PO BOX 997 , SNOQUALMIE, WA, 98065 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT TO EXISTING (PREVIOUSLY OCCUPIED) VACANT STOREFRONT SPACE. MODIFICATIONS CONSIST OF FRAMING SIX (6) NEW WALL SECTIONS 8'-0" LONG BY 8'-0" HIGH WITH END OF WALL EXTENDING UP TO JUST BENEATH EXISTING 9'-5" HIGH ACT CEILING WITH DIAGONAL FRAMING TO ROOF STRUCTURE TO SECURE AND BRACE END OF WALL. Project Valuation: $34,373.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,350.30 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No (AA. Permit Center Authorized Signature: Volumes: Cut: 0 Fill: 0 Date: 10 `dA�� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature Print Namgriece-41 Date: ,`v)-( —/ % This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 0' 0, 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or Tess. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 28: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 't ' 01 U Project No. Date Application Accepted: to Date Application Expires: -3-17 I.) -5-r7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0005800037 site Address: 666 Strander Blvd Tenant Name: US Army Recruiting Office Tukwila Suite Number: 666 Floor: 1 PROPERTY OWNER Name: MK Property Services LLC (Agent) Address: 8124 Falls Ave SE City: Snoqualmie State: WA Zip: 98065 CONTACT PERSON — person receiving all project communication Name: Sam Morris Address: 700 NW Gilman Blvd #351 City: Issaquah State: WA zip: 98027 Phone: 425-281-1632 Fax: Email: samlderl@gmail.com GENERAL CONTRACTOR INFORMATION Company Name: Enriched Designs Inc Address: 12920 SE 95th Way City: Newcastle State: WA zip: 98056 Phonc: 425-255-5467 Fax: Contr Reg No.: ENRICDI12809 Exp Date: 07/03/17 Tukwila Business License No.: BUS -0994427 II: \Applications \ Fonns-Applications On Line \2011 Applications\Pennil Application Revised - 8-9-11.doex Revised: August 20 )1 hh New Tenant: ❑ Yes ®..No ARCHITECT OF RECORD Name: k f &/ `/ c7V/Ge-- Address: -0 /e0K q4,' le0K `1 Company Name: Architect Name: Address: City: State: Zip: Phonc: Fax: Email: ENGINEER OF RECORD Name: k f &/ `/ c7V/Ge-- Address: -0 /e0K q4,' le0K `1 Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: k f &/ `/ c7V/Ge-- Address: -0 /e0K q4,' le0K `1 City: d Gt A/., A- State: �a z;p:�kOlo S� e Page 1 of4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 34,373 Describe the scope of work (please provide detailed information): Interior tenant improvement to existing (previously occupied) vacant storefront space. Modifications consist of framing six (6) new wall sections 8'-0" long by 8'-0" high, with end of wall extending up to just beneath existing 9'-5" high ACT ceiling, with diagonal framing to roof structure to secure and brace end of wall. Existing Building Valuation: $ 6,133,700 Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers NI Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If' yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:\ApplicationsWorms-Applications On Line 12011 Applications\Pennit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,612 510 0 0 Type V B -Business 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Dcck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers NI Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If' yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:\ApplicationsWorms-Applications On Line 12011 Applications\Pennit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Interior tenant improvement to existing (previously occupied) vacant storefront space. Modifications consist of framing six (6) new wall sections 8'-0" long by 8'-0" high, with end of wall extending up to just beneath existing 9'-5" high ACT ceiling, with diagonal framing to roof structure to secure and brace end of wall. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Watcr District #125 El ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highlinc 0 ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided 1=1.. Renton El .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut 0 ...Total Fill ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Usc — Potential Disturbance cubic yards 0 .. Work in Flood Zone cubic yards 0 .. Storm Drainage ❑ ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements 0 ...Traffic Control ❑ ...Backflow Prevention - Fire Protection ❑ .. Abandon Septic Tank 0 .. Curb Cut 0 .. Pavement Cut 0 .. Looped Fire Line Irrigation Domestic Water ❑ ...Permanent Water Meter Size... 0 ...Temporary Water Meter Size .. " ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 0 ...Water Main Extension Public El 71 WO# WO # WO # Private 0 Private ❑ 0 .. Grease Interceptor 0 .. Channelization 0 .. Trench Excavation 0 .. Utility Undergrounding ❑ ...Deduct Water Meter Size If FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip II:\Applications\Forms-Applications On Lmet2011 Applications\Permit Application Revised - 8-9-11.docz Revised: August 2011 hh Page 3 of 4 PERMIT APPLICATION NOTES – Value off Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no pemtit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HERF..BY CERTIFY THAT' I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH121 ED AGENT: Signature: Print Name: Date: (0 5 • Day Telephone: 4.1.5. f--.-( C.31 • \, )C-4 Mailing Address:�•`% 1: Z-;✓'" t SGL\t Cliff' l 1� City State Zip tI:'Applications\Form -Applications On Line '2011 Applicaziono\Pamilt Application Rcviscd - 8-9-11411m( Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY ' PAID $1,350.30 D17-0148 Address: 666 STRANDER BLVD Apn: 0005800037 $1,350.30 Credit Card Fee $39.33 Credit Card Fee I R000.369.908.00.00 0.00 $39.33 DEVELOPMENT $1,272.54 PERMIT FEE R000.322.100.00.00 0.00 $768.51 PLAN CHECK FEE R000.345.830.00.00 0.00 $499.53 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $38.43 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R11627 0.00 $38.43 $1,350.30 Date Paid: Monday, June 05, 2017 Paid By: CHARLES LINDBERG Pay Method: CREDIT CARD 315010 Printed: Monday, June 05, 2017 11:02 AM 1 of 1 rArR SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit b7-Q'/L6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (X Ar204 Ll aWlDA 6- T.ypeLktb)/J6 of Inspection: . l">/VAL Address: 666 �; i.. htle. RtV_ Date Called: Instructions: 10V)—Phone yt'ti Date Wante a.m. 7 17/7 cpjirSpecial Requester. No: _ zD(Lo — 1S9— //y,�_ INApproved per applicable codes. Corrections required prior to approval. COMMENTS: eC-/fit)/ t—DiN - ANA L Inspector: Date: 17 —/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D17ooi y PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: pcs- a, Type of Inspection: . ,i �1v. Address: Date Called: Special Instructions: Date Wante : Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: - rmi iN; c -- Inspector: Date: 4-17 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 J/7-3/4 y' Project: P=5, Agin/ AtzeR07AI6 46f'ii5125pa Type of Inspection: t/NG Address: 6 .5744400? &PO Date Called: Special Instructions: Date Wanted: 6 — 30 -17 (a.m) p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: �fC —sui?'t2]) eilL/4/6, Inspector: Datei 5f // REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: AV--tit&c4 —2ex v. t„,,,ks, Type of Inspection: Address:( / Suite #: Vo(f) <-..,-/-12_46.„o{cev._ Contact Person: Special Instructions Phone No.: x Approved per applicable codes. Corrections required prior to approval. COMMENTS: ( C-e,nr/mac o -z /t, c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector y --c 3 Date: 7 /j tf/ / --7 Hrs.: (. 6 r � $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 COERMIT COORD CCN C� PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0148 DATE: 06/05/17 PROJECT NAME: US ARMY RECRUITING OFFICE SITE ADDRESS: 666 STRANDER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: PMIG Building Division A)/4 (r-trr ^1 Public Wofks pi Aux 6-017 Max R Fire Prevention Structural kr 4'-7-17 Planning Division ❑ Permit Coordinator pi PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 06/06/17 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/04/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff lnitials: 12/18/2013 ENRICHED DESIGNS INC Washington State Department of Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance Search L&I A -Z Index help Page 1 of 3 My LW Workplace Rights Trades & Licensing ENRICHED DESIGNS INC Owner or tradesperson Principals LINDBERG, CHARLES C, PRESIDENT LINGBERG, PENNY J, PRESIDENT (End: 06/15/2011) LINDBERG, CHARLES C, VICE PRESIDENT (End: 06/15/2011) YANTZER-TRISTA, KAREN, SECRETARY (End: 06/15/2011) LINDBERG, NIKKI L, SECRETARY (End: 06/15/2011) Doing business as ENRICHED DESIGNS INC WA UBI No. 601 070 096 12920 SE 95TH WAY NEWCASTLE, WA 98056 425-255-5467 KING County Business type Corporation Governing persons PENNY LINDBERG SANDRA LEE BRYANT; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. ENRICDI128O9 Effective — expiration 09/29/1988— 07/03/2017 Bond TRAVELERS CAS & SURETY CO Bond account no. 103490911 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 06/02/2005 07/01/2005 Expiration date Until Canceled Insurance .................. _ ... Liberty Mutual Ins Co $1,000,000.00 Policy no. BKS57053324 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601070096&LIC=ENRICDI12809&SAW= 6/21/2017 ENRICHED DESIGNS INC Received by L&I 02/13/2017 Effective date 02/08/2017 Expiration date 02/08/2018 Insurance history Savings ..................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. ELE0000210 Issue date 02/04/2016 Violation city NEWCASTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. ELE0000209 Issue date 02/04/2016 Violation city NEWCASTLE Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Infraction no. ELE0000206 Issue date 02/04/2016 Violation city NEWCASTLE Type of violation ELECTRICAL CITATION Description Offering to perform, submitting a bid for, advertising, installing or maintaining cables, conductors or equipment that convey or utilize electrical current without having a valid electrical contractor license. Satisfied .................... _ RC VV/WAC 19.28.101 RCW Violation amount $250.00 Satisfied ....................... RC WNVAC 19.28.271 RCW Violation amount $250.00 Satisfied .......................... RCW/WAC 19.28.041 RCW Violation amount $500.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 590,013-00 Doing business as Call L&I account representative for account status. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601070096&LIC=ENRICDI12809&SAW= 6/21/2017 F- 0 w w F 0 1- '0 m w 0 w CC E3 z CC w 0 m 0 J J } z w z 0 w 0 0 ABBREVIATIONS ❑ /CL 0 / PL 0 (E) (N) ABV ACC ACOUS AD ADJ AFF AIB ALT ALUM APPROX ARCH BLKG BD BM BO BOT CAB CB CEM CER CIP CJ CL CLG CLKG CLO CLR CMD CM U CNTR CONN CONT COL CONC CORR CR CT CPT CTR (D) DBL DEG DEMO DET LL DF DIA DIM DN DO DR DW DWG E (E) EA EL EF ELEC ELEV ENCL EQ EQUIP EST EXIST z EXP 11.1 EXPO EXT 0 � F m FD FE w FF FTF c FIN a FLASH p FLR o FLUOR c FOC FOF w FDIC a w F010 FOM FOS FOF FR FRP FRPF FRPL FT FURR FUT FW S PROJECT -SPECIFIC & MAY ONLY BE USED AS SPE 7 dbaSAMo AT CENTERLINE PROPERTY LINE DIAMETER POUND OR NUMBER EXISTING NEW ABOVE ACCESS ACOUSTICAL AREA DRAIN ADJUSTABLE ABOVE FINISHED FLOOR AIR INFILTRATION BARRIER ALTERNATE ALUMINUM APPROXIMATELY ARCHITECTURAL BLOCKING BOARD BEAM BOTTOM OF BOTTOM CABINET CATCH BASIN CEMENT CERAMIC CAST -IN-PLACE CONTROL JOINT CENTER LINE CEILING CAULKING CLOSET CLR CARBON MONOXIE DETECTOR CONCRETE MASONRY UNIT COUNTER CONNECTION CONTINUOUS COLUMN CONCRETE CORRIDOR COLD ROLLED, CERAMIC TILE CARPET; CARPETED CENTER DEMOLITION DOUBLE DEGREES DEMOLITION DETAIL DOUGLAS FIR DIAMETER DIMENSION DOWN DOOR OPENING DOOR DISHWASHER DRAWING EAST EXISTING EACH ELEVATION EXHAUST FAN ELECTRICAL ELEVATOR ENCLOSURE EQUAL EQUIPMENT ESTIMATE EXISTING EXPANDED; EXPANSION EXPOSED EXTERIOR FAHRENHEIT FLOOR DRAIN FIRE EXTINGUISHER FINISH FLOOR FINISH TO FINISH FINISH FLASHING FLOOR; FLOORING FLUORESCENT FACE OF CONCRETE FACE OF FINISH FURNISHED BY OWNER - INSTALLED BY CONTRACTOR FURNISHED BY OWNER - INSTALLED BY OWNER FACE OF MASONRY FACE OF STUDS FACE OF FINISH FREAME FIBER REINFORCED PLASTIC FIREPROOF FIREPLACE FOOT OR FEET FURRING FUTURE FULL WIDTH GA GALV GC GL GLAM GR GWB HB HC HD HDO HDR HDWD HDWE HEM HM HORIZ HP HR HR HT HTF HVAC HW ID IN INSUL INT JB JF JT LAM LAV LF LH LOC LP LT MAS MAX MB MC MDO MECH MEMB MTL MFR MIN MIR MISC MTL MTD MUL N (N) N/A NIC NO NOM NR NTS 0/ OA OC OD OFF OH OPNG OPP PERF PERP PL PLAM PLAS PLWD PNL PR PRCST. PT PTN GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GLUE LAMINATED GRADE GYPSUM WALLBOARD HOSE BIBB HOLLOW CORE HEAT DETECTOR HIGH DENSITY OVERLAY HEADER HARDWOOD HARDWARE HEMLOCK HOLLOW METAL HORIZONTAL HIGH POINT HOT ROLLED HOUR HEIGHT HAMMER TO FIT HEATING / VENT ILATING /AIR CONTITIONING HOT WATER INSIDE DIAMETER INCH INSULATION INTERIOR JUNCTION BOX JOINT FILLER JOINT LAMINATE; LAMINATED LAVATORY LINEAR FEET LEFT HAND LOCATION LOW POINT LIGHT MASONRY MAXIMUM MACHINE BOLT MEDICINE CABINET MEDIUM DENSITY OVERLAY MECHANICAL MEMBRANE METAL MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MATERIAL MOUNTED MULLION NORTH NEW NOT APPLICABL E NOT IN CONTRACT NUMBER NOMINAL NOISE REDUCTION NOT TO SCALE OVER OVERALL ON CENTER OUTSIDE DIAMETER; OVERFLOW DRAIN OFFICE OVERHEAD OPENING OPPOSITE PERFORATED PERPENDICULA R PLATE PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAIR PRECAST POINT PARTITION RA RAD RB RCP RD REF RE FR REINF REM REQ RESIL REV RGTR RH RM RO RWL s S&P SAF SAM SC SD SCHED SECT SG SH SHR SHT SHT MTL. SHTG SIM SOG SPEC SQ FT SQ IN SS STA STD STL STOR STRL SUSP SYM TB TC TEL TER T&G TG THK TO TOP TOS TPH TYP RISER RETURN AIR RADIUS RUBBER BASE REFLECTED CEILING PLAN ROOF DRAIN REFERENCE REFRIGERATOR REINFORCED REMAINDER REQUIRED RESILIENT REVISION; REVISIONS; REVISED REGISTER RH ROOM ROUGH OPENING RAIN WATER LEADER SOUTH SHELF & POLE SELF -ADHERED FLASHING SELF -ADHERED MEMBRANE SOLID CORE SMOKE DETECTOR SCHEDULE SECTION SAFETY GLASS SHELF SHOWER SHEET SHEET METAL SHEATHING SIMILAR SLAB ON GRADE SPECIFICATION SQUARE FCOT (FEET) SQUARE INCH (INCHES) STAINLESS STEEL STATION STANDARE STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL TREAD TOWEL BAR TOP OF CURB TELEPHONE TERAllO TONGUE & GROOVE TEMPERED GLASS THICK TOP OF TOP OF PAVEMENT TOP OF SLAB; TOP OF STEEL TOILET PAPER HOLDER TYPICAL UNO UNLESS NOTED OTHERWISE VB VCT VEN. VERT VEST VT W W/ WC WD WF WG WH WL W/0 WIN WP WR WRB WSG 13 WT VINYL BASE VINYL COMPOSITION TILE VENEER VERTICAL VESTIBULE. VINYL TILE WEST WITH WATER CLOSET WOOD WIDE FLANGE WIRE GLACA • WATER HEATER' WATER LINE WITHOUT WINDOW WATERPROOF WATER RESISTANT WATER RESISTANT BARRIER WIRE SAFETY GLASS WEIGHT SYMBOLS LEGEND 1. GRID LINE ROOM REFERENCE 3. DOOR REFERENCE 4. WINDOW / SKYLIGHT REFERENCE 5. BUILDING SECTION 6. WALL SECTION 7 DETAIL REFERENCE 8. ELEVATION / DATUM REFERENCE 9. DETAIL REFERENCE 10. INTERIOR ELEVATION REFERENCE 11. REVISION REFERENCE 12. NORTH SYMBOL 13. SMOKE DETECTOR 14. CARBON MONOXIDE ALARM 15. EXHAUST FAN 16. SUPPLY DIFFUSER 17. EXHAUST DIFFUSER 18. DRAIN NOTES GENERAL NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS OTHER THAN THE BUILDING PERMIT ADDITIONALLY, CONTRACTOR SHALL PAY FOR ALL OTHER' CHARGES, FEES, OR COSTS ASSOCIATED WITH THE WORK AND CHARGED BY THE MUNICIPALITY, UTILITIES, OR PRIVATE COMPANIES. WHEN INCLUDED IN SCOPE OF WORK, SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, MECHANICAL, ELECTRICAL, AND FIRE SPRINKLERS. 3. GENERAL CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL EXISTING FIELD 3ONDITIONS PRIOR TO COMMENCING WORK. NOTIFY OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. ANY CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND APPROVED BEFORE COMMENCING WORK. 4. THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVAL FROM THE CONSTRUCTION SITE ALL CONSTRUCTION DEBRIS AND / OR ITEMS NOT RETAINED BY THE OWNER OR OWNER'S REPRESENTATIVE. 5. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR STRUCTURES UNTIL ALL FINAL CONNECTIONS ARE INSTALLED. 6. PROVIDE SOLID BLOCKING UNDER ALL BEARING WALLS. 7. DOORS AND CASED OPENINGS: TO BE LOCATED 6" FROM THE ADJACENT WALL UNLESS NOTED OTHERWISE, ESPECIALLY FOR HINGE SIDE; HANDLE SIDE TO FOLLOW MINIMUM ACCESSIBILITY STANDARD OF 12" CLEAR ON THE PUSH SIDE OF THE OPENING, AND 18" MINIMUM CLEAR ON THE PULL SIDE OF THE OPENING. 8. GUARDRAILS: TO BE 36"ABOVE ADJACENT WALKING SURFACE, MAXIMUM OPENING TO BE <4". ' 9. STAIR TREADS: TO BEA MINIMUM OF 10 INCHES DEEP AND ALL STAIR RISERS TO BEA MAXIMUM OF 7 3/4" HIGH. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED 3/8" IN ANY FLIGHT OF STAIRS. 10. REQUIRED GUARDS SHALL BE NOT LESS THAN 36 INCHES IN HEIGHT MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACES. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. WHERE THE TOP OF THE GUARD ALSO SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OFA SPHERE 4 INCHES IN DIAMETER FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT. 11. SAFETY GLAZING: TO BE PROVIDED PER APPLICABLE CODE REQUIREMENTS. 12. FASTENERS INTO OR IN CONTACT WITH PRESSURE -TREATED OR FIRE -RETARDANT WOOD SHALL BE OF HOT -DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON, BRONZE, OR COPPER; EXCEPTION: 1/2" DIAMETER OR GREATER STEEL BOLTS. LIVING ELEV C,CC T.®. NO. NO. II\ w DRAWINGS:: /SEPARATE PERMIT 1 REQUIRED FOR: Lf3 +a MCChan►caj £iectricaf tubing Ireas Piping City of Tukwila {.fii t INDIVISION REVISIONS No changes shalt bA made to the SCOna of work without prior approval of Tukwila Building Division.. NOTE: Revisions will require a now plan submittal ( and may include additional plan review loci C PY Permit No. Flan review ospprov9,1 is subject to errors and omission. Approval of construciion documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Ey' Date: City of Tukwila BUILDING DIVISION PROJECT INFORMATION PROJECT DESCRIPTION: INTERIOR TENANT IMPROVEMENT TO EXISTING (PREVIOUSLY OCCUPIED) VACANT STOREFRONT SPACE. MODIFICATIONS CONSIST OF FRAMING SIX (6) NEW WALL SECTIONS 8'-0" LONG BY 8'-0" HIGH, WITH END OF WALL EXTENDING UP TO JUST BENEATH EXISTING 9'-5" HIGH ACT CEILING, WITH DIAGONAL FRAMING TO ROOF STRUCTURE TO SECURE AND BRACE END OF WALL. PROPERTY ADDRESS:: 666 STRANDER BLVD, TUKWILA WA 98188 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501 030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25-23-04 - BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81-07-31 W50 FT FR C/L THOFAT HWY ENGR STA 160+00 TH FR SD POB ALG SD WLY R/W LN S 12-18-30 E 250.45 FT TAP WCH BEARS S 81-07-31 W35 FT FR C/L AT HWY ENGR STA 162+50 TH S 05-15-06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT &A C/A OF 86-22-37 ARC LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD THALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81-07-31 W 28.58 FT TH TANGENT TO PRECEDING COURS E ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19-33-22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61-34-09 W TO INTSN OF SD NLY RNV LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLYALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE THALG SD SLY LN S 87-12-48 E 194.01 FT TAP ON WLY RNV LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08-52-29 E 165.06 FT TO TPOB ASSESSOR'S PARCEL NO: 0005800 037 LOT AREA: 91,476 SF APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) (AMENDED &ADOPTED BY STAT E OF WASHINGTON; THE FOLLOWING APPENDICES, STANDARDS &AMENDMENTS ARE SPECIFICALLY ADOPTED: A. APPENDIX E, SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS; B. ICC/ANSI A117.1-2009, ACCESSIBLE & USABLE BUILDINGS & FACILITIES, WITH STATEWIDE AMENDMENTS) 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 UNIFORM PLUMBING CODE (UPC) & UNIFORM PLUMBING CODE STANDARDS 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL FUEL GAS CODE CURRENT WASHINGTON CITIES ELECTRICAL CODE (2014 NATIONAL ELECTRICAL CODE, (NFPA 70), INCLUDING ANNEX A, B & C; & STANDARDS AS ADOPTED & APPLICABLE AS AMENDED, ADDED TO & EXCEPTED IN THE WASHINGTON CITIES ELECTRICAL CODE) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 WASHINGTON STATE-WIDE AMENDMENTS BUILDING AREAS: 510 SF NEW INTERIOR CONSTRUCTION (TENANT IMPROVEMENT) WITHIN 1,612 SF EXISTING TENANT SPACE WITHIN 27,711 SF EXISTING SHOPPING CENTER BUILDING CODE INFORMATION USE GROUP: CONSTRUCTION TY PE: FIRE SPRINKLER SYSTEM: B - BUSINESS IIIB EXISTING ZONING CODE INFORMATION ZONE: MAXIMUM BUILDING HEIGHT: MINIMUM BUILDING SETBACKS: MAXIMUM BUILDING COVE RAGE: MAXIMUM IMPERVIOUS COVERAGE: TUC -TUKWILA URBAN CENTER NO CHANGE FORT HIS INTERIOR TENANT IMPROVEMENT NO CHANGE FORT HIS INTERIOR TENANT IMPROVEMENT NO CHANGE FOR THIS INTERIOR TENANT IMPROVEMENT NO CHANGE FOR THIS INTERIOR TENANT IMPROVEMENT ENERGY CODE INFORMATION PROJECT DOES NOT PROPOSE NOR REQUIRE ALTERA71ON TO THE BUILDING ENVELOPE. DRAWING LIST SITE SURVEY NA CIVIL NA ARCHITECTURAL G-0.01 COVER SHEET & PROJECT INFO A-1.01 FLOOR PLAN, SECTION, & INTERIOR ELEVATIONS A-4.01 DETA ILS STRUCTURAL NA LANDSCAPE NA MECHANICAL NA ELECTRICAL UNDER SEPARATE PERMIT (NOT DEFERRED) PLUMBING NA PROJ ECT. TEAM BUILDING OWNER: BC PARTNERS LLC AGENT: MK PROPERTY SERVICES LLC PO BOX 997 SNOQUALMIE WA 98065 CONTACT: SYD SEVERE. CELL: 425.495.1353 EMAIL: syd@mipsnet DESIGNER: dbaSAMorris 700 NW GILMAN BLVD #351 ISSAQUAH WA98027 CONTACT: SAM A. MORRIS CELL: 425.281.1632 EMAIL: sam1 de r1@gmail.com GENERAL CONTRACTOR: EDI ENRICHED DESIGNS INC. 12920 SE 95TH WAY NEWCASTLE WA 98056 WA GC Lie. ENRICDI12809 CONTACT: CHARLES C. LINDBERG CELL: 425.255.5467 EMAIL: edi-thucl.@qwestoffice.net REVIEWED FOR CODE COMPLIANCE APPROVED i.. JUN 19 2017 u44 Ci of Tukwila BUILDING DIVISION I St 510 tri t h 1 1 nderl 1. 1 27 i1 t: W 4th h 1 • 1. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH WORK. DO NOT SCALE DRAWINGS 2. INFORMATION CONTAINED WITHIN DRAWINGS WITH FEGARD TO EXISTING CONDITIONS IS PROVIDED FOR THE CONVENIENCE OF GENERAL CONTRACTOR. ALLATTEMPTS HAVE BEEN MADE TO ACCURATELY REP RESENT THE EXISTING BUILDING AND SURROUNDINGS. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK TO AVOID UNREASONABLE DELAYS. 3. NOTIFY OWNER CONCERNING QUESTIONS, CHANGES, CONFLICTS, OR OMISSIONS. OBTAIN CLARIFICATION BEFORE PROCEEDING. 4. FACE OF FRAMING IS TO BE FLUSH WITH FACE OF CONCRETE, UNLESS OTHERWISE INDICATED. 5. THE TYPICAL EXTERIOR DIMENSIONS ARE TO FACE OF CONCRETE AND / OR FACE OF FINISH, UNLESS OTHERWISE INDICATED. INTERIOR DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE INDICATED. } FLA ] I=ie APPROVED � n be &tit titar pans ` , roval from the Planning Division of DCD Approved By: Date: 10-1.. t `l VICINITY MAP IIS NTS s MATERIALS / ASSEMBLIES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. ALL WOOD AND SONOTUBE FORMS USED FOR CONCRETE IN THE GROUND OR BETWEEN FOUNDATION SILLS AND THE GROUND SHALL BE REMOVED. 3. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD, OR ANY SPECIES OF FOUNDATION GRADE CEDAR OR REDWOOD, ALL MARKED BY AN APPROVED TESTING AGENCY. 4. PROVIDE 90# FELT BETWEEN POSTS AND CONCRETE. 5. PROVIDE DRAFT STOPS, FIRE BLOCKING, AND FIRESTOPS AS REQUIRED BY CODE. 6. FLASHING AND COUNTER FLASHING TO BE MIN. 24 GAUGE OF CORROSION -RESISTANT METAL, AND SHALL BE INSTALLED IN COMPLIANCE WITH LOCAL BUILDING CODES AND MANUFACTURER'S RECOMMENDATIONS. 7. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL WALL -MOUNTED HARDWARE, INCLUDING TOILET ACCESSORIES, TOWEL BARS, LIGHT FIXTURES, BUILT-INS, GRAB BARS, ETC., AS REQUIRED FOR SECURE AND PROPER INSTALLATION. 8. ALL WOOD EXPOSED TO WEATHER SHALL BE PRESSURE TREATED, OR CEDAR, OR TREATED WITH WEATHER -PROOFING STAIN OR PAINT COATING. Z RECEIVED U CITY OF TUKWILA JUN 052017 PERMIT CENTER A o g W 0 DESIGNER: dbaSAMorris Lf) ro 0 J CO z J U' z O I\ N CON O CO Q Q co N • Q N Q zJ (r)Ow 1 U U GENERAL CONTRACTOR: EDI ENRICHED DESIGNS INC. 12920 SE 95TH WAY 0 UJ COO CD O H N ,---, (1) 0 UJ ce ce z= wU (9 Z Q O N Lf) Lf; Ln N Lf; N J J w U uJ OC U p LI - u_ LL z0 LL1 Z 00 -00 LLl I- - > 5 C�,0 0cC(') c c LIJ < CL 2 cc ZQ� DLL1U)D I -I - Df - PROJECT NO: 170531 ISSUED / REVI SED DATE BUILDING PERMIT SUBMITTAL DATE: 06-05-2017 SHEET TITLE: PROJECT INFORMATION SHEET NUMBER: G-0.01 MAIN ENTRY Al .01 TION OF DESIGNER UNIT 666 1,612 SF WAITING AREA OF WORK 510 SQUARE FEET EXISTING ROOF ASSEMBLY OFFICE DESIGNER: tn L L 0 v7 (13 .0 m 0 m cQ -J H z 0 425.281.1632 .1 w U E O u E O) ,--1 a) r1 E u) w EXISTING TRUSS ANY &ALL DIS 1 1—AREA OF WORK 1 EXISTING PARTITION BETWEEN TENANTS TYP EXISTING FOOTING & SLAB TO REMAIN TYP INTERIOR PARTITION & BRACING SEE 1/A2.01 EXISTING 2 X 4 ACT CT -SPECIFIC & M S DOCUMENT IS OFFICE OFFICE z v7 z H (1) w 0 LU c z w H 0 12920 SE 95TH WAY NEWCASTLE WA 98056 (9 c w m al 0 oo0z (N1 H(!) 0 Z = wU U (z O CELL: 425.255.5467 a) a; 0 4_ 0 a) Q' U U a) Li Q LU INTERIOR ELEVATION - SOUTH (TYP) Scale: 1/4" = 1'-0" OFFICE OFFICE EXISTING ROOF ASSEMBLY EXISTING TRUSS OFFICE EXISTING CANOPY TO REMAIN INTERIOR PARTITION BRACING SEE 1/A2.01 EXISTING 2 X 4 ACT AREA OF WORK EXISTING STOREFRONT TO REMAIN BREAK REVIEWED FOR CODE COMPLIANCE APPROVED JUN 19 2017 CO T PROJECT NO: ISSUED / REVISED DATE EXISTING FOOTING & SLAB TO REMAIN TYP UTILITY BUILDING PERMIT SUBMITTAL DATE: 06-05-2017 ELEC TEL SHEET TITLE: 2017 dbaSAMo FLOOR PLAN, BUILDING SECTION, & INTERIOR ELEVATIONS BUILDING SECTION - NORTH -SOUTH (INTERIOR EAST ELEVATION) Scale: 1/4" = FLOOR PLAN Scale: 1/4" =1-0' SHEET NUMBER: A-1.01 MMEDIATE ATTENTION OF DESIGNER D BY DESIGNER. ANY &ALL DISCREPANCIES ARE TO BE BROUGHT TO THE NOTES: 1. PROVIDE CROSS -BRACING FOR SUSPENDED ACOUSTICAL CEILING SYSTEM CI 12'-0" 0.C. BOTH WAYS WITH NO. 12 GAUGE WIRES PER ASTM C635 AND ASTM C636. 2. THE HORIZONTAL RESTRAINT POINTS FOR THE LATERAL FORCE BRACING SHALL BE PLACED NOT MORE THAN 12' 0.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' FROM EACH WALL. 3. TO FACILITATE INSTALLATION, MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS IN SUCH WAY AS TO BE INDEPENDENT OF THE WALL STRUCTURE AND SHALL BE BRACED BY LATERAL FORCE BRACING AT 12' 0.C. MAXIMUM. 4. ACOUSTICAL CEILING SYSTEMS SHALL COMPLY WITH IBC 803.9. 5. FOR AREAS EXCEEDING 1,000 S.F., HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURE ABOVE SHALL BE PROVIDED. 6. FOR AREAS EXCEEDING 2,500 S.F., A SEISMIC SEPARATION JOINT SHALL BE PROVIDED. 7, ALL PENETRATIONS SHALL HAVE A 2" OVERSIZE RING TO PROVIDE FREE MOVEMENT OF AT LEAST 1" IN ALL DIRECTIONS, 8. ALL CABLE TRAY AND ELECTRICAL CONDUITS SHALL BE SUPPORTED SEPARATELY OF THE CEILING. STEEL STUD COMPRESSION POST 112 HANGER WIRE Lu 0 U J J Lf) UJ U co a) LLJ U w Qwc� a J UI U)>- w >- rvim U W ) •:1- H • °-Ln cn OX 0000Z2o..0 000w 12 GA, VERT. WIRE (TYP,) 3 TURNS MIN. (TYP.) MAIN RUNNER OR CROSS ARMSTRONG CROSS TEE NON-COMBUSTIBLE STRUT CAPABLE OF RESISTING VERTICAL COMPONENTS INDUCED BY BRACING WIRES. FASTEN SECURELY TO STRUCTURE ABOVE. 12 G.A. VERT, HANGER WIRE @ 4'-O" O.C. BOTH WAYS OMPRESSIONPOST DESIGNER: dbaSAMorris M J CO -J Z z 0 n LATERAL FORCE BRACING 4 EA. 12 GA. WIRE SECURED TO MAIN RUNNER WITHIN 2" OF CROSS TEE INTERSECTION & SPLAYED 45' 90" FROM E.A. OTHER 12'-0" 0.C. IN BOTH DIRECTIONS W/FIRST POINT WITHIN 4'-O" FROM EA. WALL. MAIN RUNNER CROSS TEE ACOUS. TILE - FAOA MOLDING PER MANUFACTURER 2" PERIMETER WALL ANGLE ATTACH MEMBERS Q PERIMETER & TWO ADJ. WALLS ONLY. LATERAL FORCE BRACING VERTICAL WIRE SPACING ARMSTRONG MAIN BEAM ARMSTRONG ANGLE MOLDING CHANNEL MOLDING D S E PA RATI ON JOINT 12 GA. LATERAL SUPPORT WIRE WITHIN 3" OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EA. CONNECTION POINT. U Z (J) Z (9 U) w 0 w U Z w H Lu N M lG rl CO N L N J -J LU U (7 w m 0 Z J U) J • F- 0 0 l0 ui I.n N I.n N J -J LU U ARMSTRONG STABILIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. �E-- ARMSTRONG MAIN BEAM * MIN. 3/4" AT UN -ATTACHED WALLS MIN. 2" 411. 12 GA. FIXTURE SUPPORT WIRES AT CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR. 60' MAX TYP. ARMSTRONG ANGLE MOLDING ARMSTRONG STABILIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. ARMSTRONG CROSS TEE ARMSTRONG CROSS TEE MIN. 3/4" AT UN -ATTACHED WALLS / MIN. 2" I_ RECESSED FLUORESCENT FIXTURE CROSS TIE MAIN STRUCTU 4'-0" O.C. ATTACHED 2" WALL MOLDING PERIMETER COMPONENTS TYPICAL LIGHT FIXTURE BRACING TYPICAL SUSPENDED CEILING SEISMIC BRACING DETAILS (IF NEEDED FOR REPAIRS OR REINFORCEMENT) C of Tukwila NOT TO SCALE -SECURE TOP PLATE TO BLOCKING AT UNDERSIDE OF ROOF DECK ABOVE 3 1/2" 25 GA STUDS @ 48" O.C. BRACING SECURED TO BLOCKING AT UNDERSIDE OF TRUSS OR ROOF DECK LU cr O �-I- LL11— F— 0 z0 ujco �co L0 >Eco C. N. O CC (3)CC CC T. V Q • W O a. 2 cc z 2 , U X -§". U-1 z< 0 D W D ci: F- D cL TRUMENT OF SERVICE, AND NO is - THIS DOCUMENT IS AN IN CEILING GRID EDGE CLIP PER MFR PER CODE MATCH EXISTING 12 GA VERT HANGER WIRE @ 4'-0" O.C. BOTH WAYS EXISTING ACOUSTICAL CEILING TILE GRID ISSUED / REVI SED DATE 5/8" GWB PAINTED 3 5/8" INTERIOR METAL STUD �--' BASE TRIM, TYP INTERIOR PARTITION ALTERNATE CEILING GRID EDGE CLIP PER MFR PER CODE AS NEEDED 5/8" GWB PAINTED 3 5/8" INTERIOR METAL STUD BASE TRIM, TYP RECEIVED CITY OF TUKWILA JUN 0 5 2017.. BUILDING PERMIT SUBMITTAL DATE: 06-05-2017 SHEET TITLE: DETAILS SHEET NUMBER: A-4.01