Loading...
HomeMy WebLinkAboutPermit D17-0209 - BANK OF AMERICA - PARKING LOT AND ADA UPGRADESBANK OF AMERICA 320 STRANDER BLVD D17-0209 Parcel No: Address: Project Name: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 9202470050 320 STRANDER BLVD BANK OF AMERICA DEVELOPMENT PERMIT Permit Number: D17-0209 Issue Date: 9/15/2017 Permit Expires On: 3/14/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: BANK OF AMERICA NA 101 N TRYON ST NC10010381, CHARLOTTE, WA, 28255 RON PIZARRO 821 2ND AVE, STE 410 , SEATTLE, WA, 98104 Phone: (425) 974-9072 WESTMARK CONSTRUCTION INC Phone: 6102 N 9TH ST STE 400, TACOMA, WA, 98406 WESTMCI012D3 Expiration Date: 3/30/2019 BANK OF AMERICA Address: 320 STRANDER BLVD , TUKWILA, WA, 98188 DESCRIPTION OF WORK: PARKING LOT MAINTENANCE WITH VOLUNTARY ADA UPGRADES (EXTERIOR WORK ONLY - NO CHANGE TO BUILDING) WORK TO INCLUDE BUT NOT BE LIMITED TO: REMOVE/REPLACE EXISTING ADA PARKING SPACE, ACCESS AISLE AND CURB RAMP AND PROVIDING NEW RAMP FROM EXISTING WALKWAY TOWARDS ACCESSIBLE ENTRANCE OF BUILDING. REMOVE/REPLACE SECTIONS OF EXISTING CONCRETE WALKWAY. Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $856.38 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform. Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr ction or the performance of work. I am authorized to sign and obtain this development er it and a to t conditions attached to this permit. Signature: 6 -AA ` Date: 9//r//? Print Name: re51Al \ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 0 0 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***PUBLIC WORKS PERMIT CONDITIONS*** 10: Prior to construction, all utilities in the vicinity shall be field located. NOTE: For City of Tukwila utility locates, call 811 or 1-800-424-5555. 11: Any material spilled onto any street shall be cleaned up immediately. 12: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off-site or into existing drainage facilities. 13: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB CITY OF TUKjr LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila. WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. D 11 -off Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 9202470050 Site Address: 320 Strander Boulevard Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Bank of America PROPERTY OWNER Name: Ron Pizarro Name: Jim Foster (c/o Bank of America) City: Seattle State: WA Zip: 98101 Address: 800 5th Avenue, 16th Floor Email: rpizarro@nelsononline.com City: Seattle State: WA Zip: 98101 CONTACT PERSON — person receiving all project communication Name: Ron Pizarro Address: 821 2nd Avenue, Suite 410 City: Seattle State: WA Zip: 98101 Phone: (206) 974-9072 Fax: Email: rpizarro@nelsononline.com GENERAL CONTRACTOR INFORMATION Company Name: Westmark Construction Address: 6102 North 9th Street, Suite 400 City: Tacoma State: WA Zip: 98406 Phone: (253) 564-4620 Fax: Contr Reg No.: WESTMCI012D3 Exp Date: 03/30/2019 Tukwila Business License No.: GC is in the process of obtaining new City of Tukwila Business License and will update permit application at time of permit pickup. H:\Applications\Fonns-Applications On Line12011 Applications\Permit Application Revised - 0-9-1 I.docx Revised: August 7011 Ft. New Tenant: ❑ Yes ®..No ARCHITECT OF RECORD Name: Company Name: Nelson Company Name: Architect Name: Tom Spader Address: 821 2nd Avenue, Suite 410 City: Seattle State: WA Zip: 98101 Phone: (206) 886-3925 Fax: Email: tspader@nelsononline.com State: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: d Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI(J 206-431-3670 Valuation of Project (contractor's bid price): $ 20,000 Describe the scope of work (please provide detailed information): Parking lot maintenance with voluntary ADA upgrades (exterior work only - no change to building)., Work to include but not be limited to: remove/replace existing ADA parking space, access aisle and curb ramp and providing new ramp from•existing walkway towards accessible entrance of building. Remove/replace sections of existing concrete walkway. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes I21.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: i Compact: Handicap: Will there be a change in use? 0 Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm B None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 hh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: i Compact: Handicap: Will there be a change in use? 0 Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm B None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 hh Page 2 of 4 PUBLIC WORKS PERMIT INFC01ATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #l25 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ ...Valley View 0 .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ..• .Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water 0 ...Permanent Water Meter Size... ..• .Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line 11 0 ...Sewer Main Extension Public ❑ ...Water Main Extension Public 11 f> 11 11 0 0 WO # WO # WO # Private 0 Private 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size 11 FINANCE INFORMATION Fire Line Size at Property Line 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applicotions\Forms-Applications On Line\201 I Applications\Pertnit Application Revised - 0-9-1 I.docx Revised: August 2011 to, Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: ER AUTHORIZED AGENT: Print Name: ON PI 0, SENIOR PM NELSON u Mailing Address: U� Nru �$ PL, Date: 4FAgl i-1 Day Telephone: 206.974.9072 1,5001 wA- City Stale H:\ApplicationsWonns-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I1.docx Revised: August 2011 hh gs427 Zip Page 4 of 4 - Cash Register Receipt Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT I ` QUANTITY PAID $536.64 D17-0209 Address: 320 STRANDER BLVD Apn: 9202470050 $536.64 Credit Card Fee $15.63 Credit Card Fee R000.369.908.00.00 0.00 $15.63 DEVELOPMENT $496.41 PERMIT FEE R000.322.100.00.00 0.00 $491.91 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12330 R000.322.900.04.00 0.00 $24.60 $536.64 Date Paid: Friday, September 15, 2017 Paid By: TOM FRANK Pay Method: CREDIT CARD 02500G Printed: Friday, September 15, 2017 11:58 AM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $319.74 D17-0209 Address: 320 STRANDER BLVD Apn: 9202470050 $319.74 DEVELOPMENT $319.74 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12066 R000.345.830.00.00 0.00 $319.74 $319.74 Date Paid: Friday, August 04, 2017 Paid By: NELSON WORLDWIDE INC Pay Method: CHECK 385 Printed: Friday, August 04, 2017 4:10 PM 1 of 1 I • C1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ,Dr7-o9 Project: i< off lael Type of Inspection: 731l1LQ/N6- 'ANr4I-- Address: 3 STRMDER 51 -I✓ -D Date Called: Special Instructions: Date Wanted: /0 19-/ 7 a.m p.m. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: b�- '04/e/zerg n. inspector: Date:/a,f ? 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.' 1 O AdOO O8000 111111110 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0209 DATE: 08/07/17 PROJECT NAME: BANK OF AMERICA SITE ADDRESS: 320 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AWG t6Hri Building Division ON Cs Public Works ly Fire Prevention Planning Planning Division Fig Structural Permit Coordinator n PRELIMINARY REVIEW: DATE: 08/08/17 Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Structural Review Required DATE: ❑ APPROVALS OR CORRECTIONS: DUE DATE: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) 09/05/17 Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg • Fire • Ping • PW • Staff Initials: 12/18/2013 WESTMARK CONSTRUCTION I 6 Home Espanol Contact Search L&I Page 1 of 3 A -Z Index Help My L&1 Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries WESTMARK CONSTRUCTION INC Owner or tradesperson Principals JOHNSON, WARD M, PRESIDENT FRANK, THOMAS A, VICE PRESIDENT JOHNSON, BRIAN CHRISTOPHER, SECRETARY JOHNSON, JOY, SECRETARY (End: 03/11/2011) JOHNSON, W GLENN, TREASURER (End: 03/23/2011) Doing business as WESTMARK CONSTRUCTION INC WA UBI No. 600 040 824 6102 N 9TH ST STE 400 TACOMA, WA 98406-2036 253-564-4620 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. Meets current requirements. License specialties GENERAL License no. WESTMCI01203 Effective — expiration 03/23/1999— 03/30/2019 Bond Safeco Ins Co of America Bond account no. 69S001376 $12,000.00 Received by L&I Effective date 05/08/2012 04/20/2012 Expiration date Until Canceled Bond history Insurance BITCO General Ins Corp $1,000,000.00 Policy no. CLP3651252 Received by L&I Effective date 03/15/2017 03/23/2017 Expiration date 03/23/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600040824&LIC=WESTMCI012D3&SAW= 8/11/2017 Tukwila Southcenter WA3 186 ADA =ssue for PJM Review Issue for Permit 320 Strander Boulevard ukwila, Washington 98188 pgrade 7/25/2017 08/02/2017 FILE COPY Permit No. b 11- otixo Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted or ordinance. Receipt of approved Fief a . • n ions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION Er i , _ Per PiLating EYCz City of T %'.. ila BUIL INS D l/i^ION REVISIONS No changes shall he made to the scope of work witho,.,t prior approval of Tukwila Building Division, NOTE: Revisions will require a new plan submittal and may include additional plan review fees, J Project Management Jones Lang LaSalle America's, Inc. Jim Foster 800 Fifth Avenue, 16th Floor MC: WA1-501-13-02 Seattle, WA 98104 Tel: 206.200.3374 Email: jim.foster@am.jll.com Architect Nelco Architecture, Inc. Ron Pizarro 821 Second Avenue. Suite 410 Seattle, WA 98104 Tel: 425.974.9072 Email: rpizarro@nelsononline.com Attn: Ja-ay Klinthavorn Email: jkIinthavorn@neIsononIine.com General Contractor Westmark Construction Tom Frank 6102 North 9th Street, Suite 400 Tacoma, WA 98406 Tel: 253.564.4620 Ext. 203 Email: tfrank@westmarkconst.com .00" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 11 2017 Pr,J 12:2 - City of Tukwi a ING DIVISION RECEIVED CITY OF TUKWILA AUG02017 PERMIT C ai,i.l ER Architect Project #: 17.02423.00 Plot Date: 8/2/2017 12:25:32 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_A00.00.dwg User: Ja-ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb LOCATION MAP TRUE NORTH eywN DRAWING INDEX COVERSHEET ARCHITECTURAL A00.00 A00.01 A00.10 A00.40 A00.50 A00.51 A00.52 A01.01 Al2.01 Al2.03 DRAWING INDEX, PROJECT INFORMATION, CITY CODE, LOCATION MAP AND VICINITY MAP GRAPHIC SYMBOLS GENERAL NOTES ACCESSIBILITY INFORMATION & DETAILS OVERALL EXISTING SITE PLAN, EXTERIOR DEMOLITION PLAN OVERALL EXTERIOR CONSTRUCTION PLAN ENLARGED RAMP PLAN & DETAILS NOT USED EXTERIOR DETAILS NOT USED VICINITY MAP BANK OF AMERICA TRUE NORTH PROJECT INFORMATION PROJECT ADDRESS: PROJECT NAME: PROJECT SIZE & TYPE: PROJECT DESCRIPTION: PARCEL NUMBER: LEGAL DESCRIPTION: PROJECT OCCUPANCY: APPLICABLE CODES 320 STRANDER BOULEVARD TUKWILA, WASHINGTON 99301 BANK OF AMERICA - TUKWILA SOUTHCENTER 6,700 GROSS SQ. FT. EXISTING - NO CHANGE <2,000 SQ. FT. - EXTERIOR AREA OF WORK 0 SQ. FT. - INTERIOR AREA OF WORK ADA REMEDIATION - MINOR EXTERIOR PARKING LOT ALTERATION. 112039035 N.P. PLAT LOTS 4 THRU 8 BLK 22 BUSINESS ALL WORK FOR THIS PROJECT SHALL COMPLY WITH THE FOLLOWING GOVERNING CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL PROPERTY MAINTENANCE CODE/CHAPTER 16.16 ICC/ANSI A117.1 - 2003 ACCESSIBILITY CODE WASHINGTON STATE ENERGY CODE Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 E Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com Io Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS ISeal/Signature 7812 REGISTERED ARRCHITEECT OMA9'LEO SPADER STATE OF WASHINGTON IProject Name BANK OF AMERICA - TUKWILA SOUTHCENTER 1 Project Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA A00.00 IDescription DRAWING INDEX, PROJECT INFORMATION, CITY CODE, LOCATION MAP AND VICINITY MAP REVIEWED FOR CODE COMPLIANCE I Scalt APPROVED AUG 1 1 2017 City of Tukwila BUILDING DIVISION A00.00 RECEIVED CITY OF TUKWILA AUG 0 2017 PERMIT CENTER DISABLED ACCESS NOTES 1. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. 2. FLOOR SURFACES SHALL BE SLIP -RESISTANT. 3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE NOT LESS THAN 44" IN WIDTH. 4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2 5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. 6. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. IF THIS CANNOT BE ACHIEVED, REPLACE AS REQUIRED. 7. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEEL CHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. 8. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3' IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32". 9. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 10. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. WHERE ACCESSIBLE SIGNAGE IS REQUIRED, FOLLOW SECTION 703.4.1 AND 703.4.2 PER ADA 2010. 11. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. (REFER TO DWG. 2/A00.40 FOR CLEARANCES BASED ON DIFFERENT APPROACHES) 12. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 13. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. 14. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORM. 15. ENTRY TO SANITARY FACILITIES: A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE. B. DOORWAYS TO HAVE A 32" CLEAR OPENING. C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH. (REFER TO DWG. 2/A00.40 FOR CLEARANCES BASED ON DIFF. APPROACHES) 16. TOILET ROOM ACCESSORIES A. MOUNT BOTTOM EDGE OF MIRROR'S REFLECTING SURFACE NO HIGHER THAN 40" FROM THE FLOOR. B. MOUNT TOILET TISSUE DISPENSERS WITHIN 7"-9" MAX. TO CENTERLINE OF TOILET PAPER DISPENSER OPENING FROM THE FRONT EDGE OF THE TOILET SEAT. C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR. 17. SINGLE ACCOMMODATION TOILET FACILITY SEE 12/A00.40 FOR CLEARANCE REQUIREMENTS 18. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17" AND 19" 19. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF THE TOILET WITH THE GREATEST SEPARATION FROM ADJACENT WALL OR OTHER SURFACE. 20.PROVIDE GRAB BARS ON EACH SIDE, OR ONE SIDE AND BACK OF WATER CLOSET. A. GRAB BARS TO BE 33" ABOVE AND PARALLEL TO THE FLOOR. B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT BACK TO BE 36" LONG. C. DIAMETER OF GRAB BARS TO BE 1-1/4" TO 1-1/2". D. PROVIDE 1-1/2" CLEARANCE BETWEEN GRAB BARS AND WALL. E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL SUPPORT A 250 POUND LOAD. F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. G. GRAB BARS AND ANY ADJACENT SURFACE SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". 21.PROVIDE A CLEAR FLOOR SPACE 30" X 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH. 22.MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT UP EXTENDING A MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH, AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY. 23. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF CLOSING VALVES ARE USED, FAUCET REMAINS OPEN A MINIMUM OF 10 SECONDS. 24. INSULATE OR OTHERWISE COVER HOT WATER AND DRAIN PIPES UNDER LAVATORIES. 25. THE AMERICANS WITH DISABILITIES ACT (A.D.A.) PROVIDES THAT ALTERATIONS TO A FACILITY MUST BE MADE IN SUCH A MANNER THAT, TO THE MAXIMUM EXTENT FEASIBLE, THE ALTERED PORTIONS OF THE FACILITY ARE READILY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES. BANK AND GENERAL CONTRACTOR ACKNOWLEDGES THAT THE REQUIREMENTS OF A.D.A. WILL BE SUBJECT TO VARIOUS AND POSSIBLY CONTRADICTORY INTERPRETATIONS. THE ARCHITECT THEREFORE, WILL USE ITS BEST PROFESSIONAL EFFORTS TO INTERPRET A.D.A. REQUIREMENTS AND OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THE PROJECT. THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT BANK OF AMERICA WILL COMPLY WITH ALL INTERPRETATIONS OF THE A.D.A. REQUIREMENTS AND/ OR THE OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THE PROJECT. 26. THE SCOPE OF WORK INDICATED ON THESE DRAWINGS IS FOR SPECIFIC ITEMS SELECTED BY BANK OF AMERICA FOR CUSTOMER ACCESS TO GOODS AND SERVICES; NOTE THAT SOME AREAS OF ACCESS HAVE NOT BEEN MODIFIED TO MEET A.D.A. REQUIREMENTS. ALL OTHER AREAS OF A.D.A. UPGRADE THAT MAY BE REQUIRED AT THIS TIME ARE NOT IN THIS CONTRACT AND ARE NOT INDICATED ON THESE DOCUMENTS. SEE BANK OF AMERICA FOR ADDITIONAL INFORMATION CONCERNING OTHER AREAS OF A.D.A. SCOPE OF WORK. FIRE DEPARTMENT NOTES 1. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 2. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. 3. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 4. DOORS OPENING INTO REQUIRED 1 -HOUR, FIRE -RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20 -MINUTE RATING AND SHALL BE SELF-CLOSING. 5. 20 -MINUTE DOOR JAMBS TO BE TIGHT -FITTING, SMOKE AND DRAFT CONTROLLED. 6. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. 7. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION. 8. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. 9. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 10. HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE AND SHALL BE SYNCHRONIZED. 11. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FINISHED FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 12. CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL PROTECTED OPENINGS, CORRIDOR PARTITIONS, SMOKE STOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT ENCLOSURES AND ALL FIRE RATED WALLS WITH CORRESPONDING HOURLY RATING BY EITHER INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE FOLLOWING: "1 HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS". NOTE: IDENTIFICATION SHALL BE SPACED NO MORE THAN TWELVE (12) FEET ON CENTER WITH A MINIMUM LETTER SIZE OF TWO 02) INCHES IN HEIGHT ON A CONTRASTING BACKGROUND. 13. DEVICE COVERS TO BE TO MATCH LUTRON LIGHT ALMOND UNLESS DICTATED OTHERWISE BY LOCAL JURISDICTIONS. 1. ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (A.D.A.) ALONG WITH ALL STATE, COUNTY, AND LOCAL APPLICABLE CODES, ORDERS, ORDINANCES AND REGULATIONS. NOTIFY ARCHITECT PRIOR TO START OF WORK OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND CODE. ALL WORK SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENT. 2. BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME FAMILIAR WITH DRAWINGS SCOPE OF WORK AND VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE SITE AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. PRIOR TO STARTING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT TO BANK OF AMERICA PROJECT MANAGER AND ARCHITECT AN ITEMIZED COST BREAKDOWN OF ALL SCOPE ITEMS AND A CONSTRUCTION SCHEDULE. WORK TO BE SCHEDULED TO MEET BANK OF AMERICA REQUIREMENTS. 4. ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND ALL WORK DEPENDENT UPON OR NECESSARY TO COMPLETE THIS WORK SHALL BE EXECUTED IN A WORKMAN LIKE MANNER CONSISTENT WITH THE BEST STANDARDS OF THE TRADE INVOLVED AND BE OF ITEMS AND MATERIALS SUITED FOR THE PURPOSE INTENDED. 5. TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN, AND SUPERVISORS ARE TO BE SKILLED, EXPERIENCED AND LICENSED IF REQUIRED IN THE WORK THEY WILL BE PERFORMING. 6. PROJECT CONSTRUCTION ITEMS TO BE NEW, UNLESS OTHERWISE NOTED. NO SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE DESCRIPTIONS OF ITEMS INCLUDING DRAWINGS, TEST DATA, SAMPLES, COST AND SCHEDULE CHANGES ARE SUBMITTED BY THE CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. ANY ITEM NOTED ON THE DRAWINGS THAT ARE NOT AVAILABLE OR WOULD CAUSE A TIME DELAY SHALL BE IDENTIFIED BY THE GENERAL CONTRACTOR AND THE ARCHITECT NOTIFIED. 7. TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLICABLE U.N.O. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF CONTRACTOR HAS ANY QUESTIONS REGARDING THE SAME OR EXACT MEANING, ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. 8. DIMENSION LINES ARE TO FACE OF FINISH ON EXISTING AND NEW WORK, UNLESS NOTED AS FACE OF STUD OR MASONRY OR CENTERLINE OR OTHERWISE. DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE AND LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 9. PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL FABRICATION OR WHERE THEY ARE CALLED OUT FOR ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL SUBMIT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. REQUIRED CORRECTIONS WILL BE NOTED AND A COPY WILL BE RETURNED TO THE CONTRACTOR WHO SHALL REVISE DRAWINGS AND RESUBMIT FOR FINAL APPROVAL PRIOR TO FABRICATION. 10. CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 11. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS -BUILT DRAWINGS NOTING DEVIATIONS BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS AND NEW CONSTRUCTION OF ALL TRADES AND DELIVER TO BANK OF AMERICA AT END OF PROJECT. GENERAL CONTRACTOR SHALL PROVIDE ALL SUBCONTRACTORS WITH THE MOST CURRENT CONSTRUCTION DOCUMENTS THROUGHOUT THE PROJECT, INCLUDING ALL REVISIONS. 12. CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA PROJECT MANAGER OF ALL REVISIONS TO THE DRAWINGS AND CHANGES WITH THE SCOPE OF WORK OR SCHEDULE REQUIRED BY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF AMERICA PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN WRITING AS CHANGE ORDERS AND APPROVED PRIOR TO STARTING WORK. 13. CONTRACTOR TO PROVIDE EQUIPMENT TO ENSURE LIFE SAFETY OF PUBLIC, TENANTS AND WORKERS AS REQUIRED BY FEDERAL, STATE AND LOCAL CODES THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT PEDESTRIANS. 14. CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND REQUIREMENTS OF NEW CONSTRUCTION PRIOR TO START OF WORK. CONTRACTOR SHALL FURNISH ADEQUATE SHORING, BRACING, ETC. AS REQUIRED TO SAFELY EXECUTE ALL WORK AND SHALL BE FULLY RESPONSIBLE FOR SAME, UNLESS SPECIFICALLY DETAILED IN THE DRAWINGS. CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORTS AS NECESSARY FOR ALL FIXTURES, EQUIPMENTS AND ALL OTHER ITEMS REQUIRING SAME. 15. SITE AND BUILDING SHALL BE MAINTAINED IN A CLEAN, SAFE MANNER, DIRTY/ NOISY WORK SHALL BE PERFORMED AT SUCH TIME AS DIRECTED PER THE OWNER AND/OR CITY WHEN THE WORK VARIOUS SECTIONS ARE COMPLETED, AND AT OTHER TIMES AS DIRECTED BY BANK OF AMERICA, OR OWNER, ALL TRASH DEBRIS, SURPLUS MATERIAL, TOOLS AND EQUIPMENT TO BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. LEAVE PREMISES IN A CONDITION ACCEPTABLE TO BANK OF AMERICA, OR OWNER. 16. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. WHERE EXISTING CONSTRUCTION, FINISHES OR EQUIPMENT IS DAMAGED BY WORK IN THIS CONTRACT, THEY SHALL BE PATCHED, REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING, BY TRADE WHOSE WORK IS DAMAGED AT NO COST TO BANK OF AMERICA. 17. LAYOUT OF WORK: A. LOCATION AND ELEVATION OF ALL WORK TO BE CONSTRUCTED ARE SHOWN ON DRAWINGS AND UNLESS DISCREPANCIES ARE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND INTENDED. B. THE CONTRACTOR SHALL LAYOUT THE WORK AND SHALL ESTABLISH AND MAINTAIN NECESSARY MARKERS, AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF SAME. THE CONTRACTOR SHALL LAYOUT, AS A GUIDE TO ALL TRADES AND TO HIS SUBCONTRACTORS, THE EXACT LOCATIONS OF NEW OR REMODEL WORK WITH RESPECT TO CHANGES TO EXISTING. 18. INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC. INCLUDING THE PREPARATION OF SURFACES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED RECOMMENDATIONS AND INSTALLATION REQUIREMENTS. 19. PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND RELOCATION OF ANY EXISTING EQUIPMENT OR CONSTRUCTION AS NECESSARY FOR A COMPLETE INSTALLATION. 20. ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT SWITCHES, VALVES AND OTHER CONTROL DEVICES THAT ARE CONCEALED. EXACT LOCATIONS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 21.BESIDES GUARANTEES REQUIRED ELSEWHERE, THE CONTRACTOR SHALL, HEREBY DOES, GUARANTEE ALL WORK FOR A MINIMUM PERIOD OF ONE YEAR AFTER DATE OF ACCEPTANCE OF WORK WITH ANY OTHER WORK, WHICH MAY BE DISPLACED IN SO DOING, THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND/OR MATERIALS WITHIN A MINIMUM OF ONE YEAR PERIOD FROM THE DATE OF ACCEPTANCE WITHOUT EXPENSE TO BANK OF AMERICA. 22.OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 23.SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. 24.OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION 25.000RDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 26.PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 27.D0 NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 28.000RDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 29.UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED. 30.CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND A SMOKE -DEVELOPED INDEX OF MOT MORE THAN 450. 31.INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL FIRE ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN UNCONCEALED SPACES SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450. 32.MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84. SPECIFICATIONS CONCRETE: 1. UNLESS OTHERWISE, ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. 2. AGGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C33. 3. CEMENT SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C-150. TYPE I OR II, LOW ALKALI, OR AS REQUIRED TO SATISFY SITE SOIL CONDITIONS AS DETERMINED BY THE PROJECT SOILS ENGINEER. 4. WATER SHALL BE POTABLE, CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OIL, ACIDS, ALKALIS, SALTS, ORGANIC MATERIALS OR OTHER SUBSTANCES THAT MAY BE DELETERIOUS TO CONCRETE OR REINFORCEMENT. 5. ADMIXTURES TO BE USED IN CONCRETE SHALL BE SUBJECT TO PRIOR APPROVAL BY THE ENGINEER. 6. MAXIMUM PERMISSIBLE WATER -CEMENT RATIOS FOR CONCRETE WHEN STRENGTH DATA FROM TRIAL BATCHES ARE NOT AVAILABLE SHALL CONFORM TO TABLE 4.5 OF THE ACI STANDARD 318-77 OR BASED ON SULFATE CONTENT OF THE SITE SOILS. AS DETERMINED BY THE SOILS ENGINEER. THE LOWER WATER -CEMENT RATIO SHALL GOVERN. 7. CONCRETE SHALL BE CURED WHILE IN A MOIST CONDITION FOR AT LEAST THE FIRST 7 DAYS AFTER PLACEMENT. METHODS FOR ACCELERATED CURING SHALL HAVE PRIOR APPROVAL OF THE ENGINEER. 8. THE FOLLOWING MINIMUM CLEAR DISTANCE BETWEEN REINFORCING STEEL AND FACE OF CONCRETE SHALL BE MAINTAINED UNLESS NOTED OTHERWISE. SLABS ON GRADE CENTER OF SLAB CONCRETE BELOW GRADE, FORMED 2" CONCRETE BELOW GRADE,UNFORMED 3" (POURED AGAINST EARTH) CONCRETE EXPOSED TO WEATHER 1 1/2 " Dig- oLy Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 NE s Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com IO Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS ISeallSignature 1 Project Name 7892 i REGISTERED ARCHITECT Q THOMAS • 0 SPAD R 'STATE OF WASHINGTON BANK OF AMERICA - TUKWILA SOUTHCENTER IProject Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA A00.10 Description GENERAL NOTES I Scale REVIEWED FOR CODE COMPLIANCE APPROVED AUG 11 2017 City of Tukwila BUILDING DIVISION AOO1O RECEIVED CITY OF TUKWILA AUG 0 2017 PERMIT CENTER Plot Date: 8/2/2017 12:25:49 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_A00.40.dwg User: 3a -ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb NOTE: ALL BANK SIGNAGE TO BE VERIFIED PER SITE REQUIREMENTS AND PROVIDED BY BANK SIGN VENDOR. VAN ACCESSIBLE PARKING SIGN TYP. SEE DETAIL 6/Al2.01 2% SLOPE MAX. IN ANY , DIRECTION (TYP.) WITHIN THE LOADING AND UNLOADING ACCESS AISLE, PAINT THE WORDS "NO PARKING" IN 12" HIGH LETTERS MIN. PAINT 4" WIDE BLUE STRIPING TYP. ACCESSIBLE PARKING SIGN PER LOCAL REQ'S PEDESTRIAN ROUTE EQ. t EQ. STRIPES AT 36" O.C. (TYP.), TYPICAL PAVEMENT SYMBOL, 48"x48" SEE DETAIL 7B/A00.40 8'-0"(MIN.) 2" 8'-0"(MIN.) OF c. STRIPE (TYP.) 5'-0" MIN. AT TYP. ACCESSIBLE PARKING STALL, 8'-0" MIN. AT VAN ACCESSIBLE PARKING STALL ACCESSIBLE PARKING STALLS SCALE: N.T.S. 9 r -J Ew 9 it 2 cn ATM, DISPLAY FEATURES AND REACHABILITY MUST CONFORM TO IBC CHAPTER 11 AND ADA REQUIREMENTS. ATM -- I L_ 4'-0" LINE OF REQUIRED CLEARANCE ATM CLEARANCES SCALE: 1/2" = 1'-0" 10 0 12" GROOVES PER NOTE 1 CV 8.3% 8.3% FINISH PER NOTE 2. CURB TRANS 0" CF 4' MIN. CURB TRANS ACCESS RAMP CONSTRUCTION NOTES 1. RAMP SHALL HAVE A 12" WIDE BORDER WITH 1/4" X 1/4" GROOVES @ 3/4" OC. SEE DETAIL 1/Al2.01. 2. THE SURFACE OF THE RAMP SHALL HAVE A TRANSVERSE BROOMED SLIP -RESISTANT SURFACE TEXTURE ROUGHER THAN THE SURROUNDING SIDEWALK. 3. RAMP CONSTRUCTION SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL CODES AND REGULATIONS. CURB RAMP SCALE: N.T.S. 11 18" MIN. 15" MAX. KNEE CLEARANCE 8" MIN. CENTER ON LOWER FOUNTAIN z 2 M z 2 5 9 6" MAX TOE CLEARANCE CLEAR FLOOR SPACE AT HIGH/LOW FOUNTAIN TYPES CENTER THE 30"X48" CLEAR SPACE ON LOWER FOUNTAIN DRINKING FOUNTAIN SCALE: 1/2" = 1 -0 i r17"x22" MIN. Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities will be towed away at the owner's expense. Towed vehicles may be reclaimed at or by telephoning 1 A BORDER AND IMAGE TO BE PAINTED w/ WHITE REFLECTORIZED TRAFFIC PAINT ON BLUE BACKGROUND. 4,-0" CENTERLINE OF SYMBOL AND PARKING STALL EQ. i EQ. f - i 4 1/2') 3'-3" B 1- z 18'-0" FROM CURB 4 1/2" ACCESSI ,BLE SIGNAGE SCALE. 1/4 1 0 2 9 �i- z 2 M 10" MAX. • 4'-0" y 10"2'-6" 1 MAX.1 SIDE REACH RANGE L 2'-8" MIN. 3'-0" MIN. 9 2'-0" MAX. DEPTH FOR MIN. CLEARANCE REACH RANGES SCALE: 1/2" = V-0" 3 Lobby z 5 c 4" MAX. HIGHERI THAN 2'-3" CLEA WIDTH ANY A MOUNT O LU COO M N ROTRUDING OBJECTS 4 SCALE: 1/4" V-0" I r. 9 1'-6" Jr z T I I NOTE: X = 1'-0" IF DOOR HAS BOTH A CLOSER AND A LATCH r 4 // NOTE: X =3'-0" MIN. IF Y=5'-0"; X= 3'-6" MIN. IF Y=4'-6". <- 2 -0 - 2'-0" NOTE: Y= 4'-0" MIN.; Y=4'-6" MIN. IF DOOR HAS A CLOSER 4'-6" F I<— NOTE: Y= 3'-6" MIN.; Y=4'-0" MIN. IF DOOR HAS A CLOSER r 2'-0" Ar NOTE: = 3'-6" MIN.; Y=4'-0" MIN. IF DOOR HAS A CLOSER CLEARANCES SCALE: 1/2" = 1'-0" D+� THRESHOLDS SCALE: FULL Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 NEL Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com IL Issue Date & Issue Description By Check 1 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS !Seal/Signature Project Name 7812 REGIS ERLL; ARCHITECT OMA , 0 SPADER STATE OF WASHINGTON 6 BANK OF AMERICA - TUKWILA SOUTHCENTER IProject Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA A00.40 IDescription ACCESSIBILITY INFORMATION & D REVIEWED FOR ' TPIkOVED AUG 11 2017 City of Tukwila BUILDING DIVISION A00.40 RECEIVED CITY OF TUKWILA AUG 0 2017 PERMIT CENTER Plot Date: 8/2/2017 12:25:57 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_A00.50.dwg User: Ja-ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb KEY NOTES: EXISTING BANK OF AMERICA BUILDING TO REMAIN - NO CHANGE IN SQUARE FOOTAGE OR USE. EXISTING BANK OF AMERICA DRIVE-THRU - NOT IN PROJECT SCOPE. EXISTING PARKING TO REMAIN. EXIST LANDSCAPE TO REMAIN. EXISTING PARKING AND LOADING AISLE STRIPING TO BE REMOVED WHERE NEW ASPHALT OVERLAY TO BE INSTALLED, REFER TO SHEET A00.51 FOR NEW PARKING LAYOUT AND EXTENT OF NEW ASPHALT PAVING. REMOVE SECTION OF EXISTING CONCRETE WALKWAY, CURB AND RAMP WHERE SHOWN DASHED AT EXISTING EXPANSION JOINTS - VERIFY EXPANSION JOINT LOCATIONS IN FIELD PRIOR TO CONSTRUCTION. EXISTING CONCRETE WALKWAY TO REMAIN. CrelbeXPCIIPCIMICZOCIPMPIR=1141:MUMmoiempainip GRAPHIC SYMBOLS — — — TO BE REMOVED KEYNOTE Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 NEL Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com A Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS !Seal/Signature 7812 REGISTERED ARCHIT CT 1 Project Name THOMAS E0 SPADER STATE OF WASHINGTON BANK OF AMERICA - TUKWILA SOUTHCENTER IProject Number 17.02423.00 1 CAD File Name WA3-186 SOUTHCENTER ADA A00.50 1 Description OVERALL EXISTING SITE PLAN, EXTERIOR DEMOLITION PLAN !Scale 0 4' 8' 16' SCALE: 1/8" =1'-0" A00.50 NORTH 32' 48' EerIN EIV CITY OF TUKA AUG 0 ' 2017 PERMIT CENTER Plot Date: 8/2/2017 12:26:06 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_A00.51.dwg User: Ja-ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb TYP. KEY NOTES: 0 EXISTING BANK OF AMERICA BUILDING TO REMAIN - NO CHANGE IN SQUARE FOOTAGE OR USE. 2 ACCESS AISLE PARKING STALLS PER ACCESSIBILITY STANDARDS. SEE ACCESSIBLE PARKING DETAIL 9/A00.40 FOR MINIMUM REQUIREMENTS. 2% MAX. RUNNING SLOPE ANY DIRECTION FULL LENGTH AND WIDTH OF PARKING STALLS. NEW REPLACED CONCRETE RAMP AND NEW HANDRAILS , SEE DETAIL 1/A00.52, FOR FURTHER INFORMATION. REMOVE EXISTING SIGNAGE AND INSTALL BOLLARD SLEEVE OVER EXISTING 6" BOLLARD. SEE DETAIL 6/Al2.01 FOR FURTHER INFORMATION. CONCRETE LEVEL PAD AT ENTRY DOORS, MEASURED 5'-0" IN LENGTH FROM FACE OF DOORS, 2% MAX. IN ANY DIRECTION CURB RAMP - SEE DETAIL 11/A00.40 FOR MINIMUM CONSTRUCTION REQUIREMENTS. MAX. RUNNING SLOPE OF 1:12, MAX. CROSS SLOPE OF 2%. EXISTING SIDEWALK TO REMAIN. 4" PARKING STRIPING MATCH EXISTING. NEW POST -MOUNTED DIRECTIONAL SIGNAGE READING "ACCESSIBLE ENTRANCE" PER DETAIL 3/Al2.01. 10 NEW ASPHALT PAVING AT DRIVE -WAY. PROVIDE SMOOTH AND SEAMLESS TRANSITION FROM NEW ASPHALT PAVING TO EXISTING ADJACENT PAVING. 11 4 {a m ///////f/1///// BANK OF AMERICA 6,700 SF 0 ('3 4 NEW REPLACED CONCRETE WALKWAY TO MATCH EXISTING LAYOUT AND DIMENSIONS, CROSS SLOPE 2% MAX., RUNNING SLOPE 5% MAX. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD. PROVIDE SMOOTH AND LEVEL TRANSITION FROM NEW CONCRETE SURFACE TO ADJACENT. NEW EXPANSION JOINTS TO BE 20'-0" O.C. AND NEW TOOL JOINTS TO BE 4'-0" O.C. SEE DETAILS 7/A00.52 FOR FURTHER INFO. ADA SYMBOL STRIPING PER DETAIL 7/A00.40. EXISTING PARKING TO REMAIN. INSTALL MISSING COMPONENT OF DOOR THRESHOLD, OR REPLACE ENTIRE THRESHOLD AS NECESSARY, TO ACCOMMODATE DOOR SWEEP AND CLEARANCE. THRESHOLD TO BE 1/4" MAX GAP HEIGHT, OR 1/2" MAX WITH 1/4" BEVELED EDGE. SEE DETAIL 2/A.0040 GRAPHIC SYMBOLS: NEW CONCRETE PAVING/WALKWAY (APPROXIMATELY 1,300 SF) NEW ASPHALT OVERLAY PAVING REVIEWED FOR CODE COMPLIANCE APPROVED AUG 11 2011 City of Tukwila BUILDING DIVISION 020 Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3 -18 6 EL Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com Io Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS ISeal/Signature IProject Name 7812 REGISTERED ARCHITE T MAS L 0 SPADER STATE OF WASHINGTON BANK OF AMERICA - TUKWILA SOUTHCENTER !Project Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA A00.51 !Description OVERALL EXTERIOR CONSTRUCTION PLAN I Scale 0 2'-0" 4'-0" 8'-0" SCALE: 1/4" = 1'-0" A00.51 NORTH RECEIVED ITY OF TUKWILA AUG 0 !) 2017 INTERMIT CENTER Plot Date: 8/2/2017 12:26:12 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_A00.51.dwg User: Ja-ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb 1 1/2" DIA. TOP RAIL PIPE POST 1 1/2" DIA. RAIL 3" FLAT BOTTOM RAIL (THIS SIDE ONLY) HANDRAIL POST WITH FLOOR FLANGE AND COVER =111,111,111,1f III=III=III=I I I— -_,III���III1111111�111, a 4 3'-0" MIN. 3" —111-111-111-1 111=111=111=111- -=-1 11E111=111E1 111=1T MATCH EXIST TYP. SECTION AT ADA RAMP SCALE: 1" = 1'-0" ., .47 12" a RUNNING SLOPE 1:12 (8.33„% MAX) -J MATCH EXIST KEY NOTES: OCONFIRM CONCRETE/LEVEL LANDING, AT TOP AND BOTTOM OF NEW RAMP 2% MAX. IN ANY DIRECTION MEASURED 4'-0" FROM EDGE OF RAMP. NEW CONCRETE RAMP, CROSS SLOPE 2% MAX., RUNNING SLOPE 8.33% MAX. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD. PROVIDE SMOOTH AND LEVEL TRANSITION FROM NEW CONCRETE SURFACE TO ADJACENT. NEW EXPANSION JOINTS TO BE 20'-0" O.C. AND NEW TOOL JOINTS TO BE 4'-0" O.C. SEE DETAIL 7/00.52 FOR FURTHER INFO. EXISTING SIDEWALK TO REMAIN. `•, " 4.7 `4/ `%l .47 '•, .f, .47 •/ %/////////////////// GRAPHIC SYMBOLS: 4 4 NEW CONCRETE PAVING/WALKWAY 0 2'-0" 4'-0" 8'-0" SCALE: 1/4" = 1'-0" NORTH KEY PLAN: SI ( AREA OF WORK BANK OF AMEMCA f,. sem €>;�'.,. NEW CONCRETE RAMP - ENLARGED PLAN 061/2"." SCALE: = 1 -0 PROVIDE SEALANT TO 3/8" FROM TOP OF CONCRETE SMOOTH TOOLED FINISH (TYP.) SUB BASE PER SOILS REPORT 1/4" TOOLED RADIUS EACH SIDE 1/4" PREMOLDED EXPANSION JOINT FILLER COMPACTED BASE PER SOILS REPORT LU 0 a4 // EQUAL f 1/4" EQUAL FOR FINISH, SEE PLANS. 0 oB6 II' '-6illi [V " N.T.S. 6x6/W 1.4xW 1.4 MESH REINFORCEMENT UNLESS OTHERWISE NOTED. #5 SMOOTH DOWELS 16" LONG AT 24" O.C. GREASE 8" LENGTH AT ONE END EXPANSION JOINT @ SIDEWALK SCALE: N.T.S. 01 TYP. ELEVATION AT ADA RAMP SCALE: 1/2" =11-0" 02 SEALANT OVER 1/2" PERFORMED EXPANSION JOINT FILLER CONCRETE PAVING 4" REINFORCING BARS AT 12" O.C. COMPACT SUBGRADE 07 FLUSH PAVING CONDITION SCALE: N.T.S. TOOLED CONTROL JOINT 4 4 a. 4 4 -•—•000-•—•.•X-• •�I�I�I�I�I�I-I-1'•���I�I'•�I�I�I�I=•�I�1�1•I���I�1=1�1� ‘440i•i i� .. i . i i... CONCRETE PAVING 4" REINFORCING BARS AT 12" O.C. COMPACT SUBGRADE 410 0505 FLUSH PAVING CONDITION SCALE: N.T.S. 03 Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 NELSON Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS ISeal/Signature IProject Name 7812 REGISTERED ARCHITECT 0 EO SPADER STATE OF WASHINGTON BANK OF AMERICA - TUKWILA SOUTHCENTER IProject Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA A00.52 Description ENLARGED EXTERIOR CONSTRUCTION PLAN & DETAILS 'tie REVIEWED FOR c6..j0#j)IVMPLIANCE APPROVED AUG 11 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 Pj 2017 PERMIT CENTER Plot Date: 8/2/2017 12:26:23 PM Filename: U:\Traditional Services\Bank Of America\WA\17.02423.00-BAC ADA - Southcenter\DRAWINGS\ARCH\CD\WA3-186_Southcenter ADA_Al2.01.dwg User: Ja-ay Klinthavorn Device: DWG To PDF.pc3 PenTable: _NELSON-HALF.ctb NOT USED SCALE: 1" = 1'-0" 7 NOT USED SCALE: 1" =11-0" 8 NOTSCALE: -USED 9 NOT USED SCALE: 3" = 1'-0" 4 EXISTING SIGNAGE TO REMAIN. REINSTALL AFTER BOLLARD SLEEVE IS PLACED EXISTING CHANNEL POST NEW YELLOW SIGN/BOLLARD COVER W/ RED REFLECTIVE TAPE FIELD DRILL OPENING OF CHANNEL POST DIAMETER VAN ACCESSIBLE PENALTY 5;50. 1,7 OFFENSE SOV EQ IENd•,'OFFENSES $260. MN. ANOJOR UP TO 90 DAYS COMMUNITY SERVICE TOW AWAY ZONE ATS AM'S. E: M. TOP OF EXISTING CURB ti NOTES: 1. INSTALL PER BANK STANDARDS. SIGNAGE TO COMPLY WITH ALL LOCAL JURISDICTIONS. 2. BOLLARD NOT REQUIRED IF ACCESSIBLE SIGNAGE IS LOCATED IN CRASS AND OVER THREE (3) FEET BEYOND THE BACK OF THE CURS. 3. BOLLARD SHALL BE IDEAL SHIELD 1/8" STANDARD BOLLARD COVER, 1.90'OUTSIDE DIAMETER, 1/8" NOMINAL WALL THICKNESS, COLOR OSHA YELLOW, TO TOP PLASTIC CAP. 4. CONTRACTOR SHALL COORDINATE INSTALLATION OF BOLLARD COVER PRIOR TO SIGNAGE INSTALLATION. GROUND MOUNTED SIGNAGE SCALE: N.T.S. 6 1/4" d d 3/4" Q " d n z 1V-0" GROOVED BORDER DETAIL SCALE: 3" = 11-0" ^11.5MM(.45") 42 MM(1.66") N I I Ln 23 MM(.9"5 ) s N TRUNCATED DOMES 1/4" 3/4" 1 1 DETAIL SECTION CURB RAMP DETAILS SCALE: 1/4" = 1'-0" 2 2'-0" 5'-0" MIN. AFF • Accessible Entrance 4 O d O POST -MOUNTED 2'-0" 0 cV • Accessible Entrance WALLMOUNTED ot7 NOTE: ACCESSIBLE ROUTE SIGNAGE PER BAC STANDARD. GC TO VERIFY MOUNTING HEIGHT AND SPECIFICATIONS WITH PJM AND BAC VENDOR DRAWINGS BY MONIGLE. BAC WAYFINDING SIGNAGE SCALE: 1-1/2" = 1'-0" 3 Bank of America Tukwila - Southcenter ADA Upgrade 320 Strander Boulevard Tukwila, Washington 98188 Manhattan ID: WA3-186 NE Nelco Architecture, Inc. a licensed affiliate Architect: Firm Name: Nelson / Nelco Architecture Inc. Attn: Ron Pizarro T: 219.886.3919 E-mail: RPizarro@nelsononline.com It Issue 1 Date & Issue Description By Check 07.25.2017 ISSUE FOR PJM REVIEW RP RP/AS 2 08.03.2017 ISSUE FOR PERMIT RP RP/AS/TS ISeal/Signature !Project Name 7812 REGISTEHL D` ARCHITECT THO "S `' 0 PADER STATE OF WASHINGTON BANK OF AMERICA - TUKWILA SOUTHCENTER 1 Project Number 17.02423.00 ICAD File Name WA3-186 SOUTHCENTER ADA Al2.01 IDescription EXTERIOR DETAILS scai�_:�_EV1EVVEDUFOR LIAPICE XPPROVED AUG 11 2017 City of Tukwila BUILDING DIVISION Al2.01 RECEIVED CITY OF TUKWILA AUG 0 11 2017 PERMIT CENTER