Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0214 - MCDONALD'S - TENANT IMPROVEMENT
MCDONALD'S 15210 INTERNATIONAL BLVD D17-0214 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0043000090 Permit Number: D17-0214 15210 INTERNATIONAL BLVD Project Name: MCDONALD'S Issue Date: 9/5/2017 Permit Expires On: 3/4/2018 Owner: Name: Address: COMISKEY ROBERT 18161 NORMANDY TERRACE SW C/O MCDONALD'S, NORMANDY PARK, WA, 98166 Contact Person: Name: DIANE MULLINAX Address: 7038 S 220TH ST, KENT, WA, 98032 Contractor: Name: DB GENERAL CONTRACTORS INC Address: 7038 S 220TH ST , KENT, WA, 98032 License No: DBGENGC94309 Lender: Name: MCDONALD'S USA Address: 12131 113TH AVE NE #103 , KIRKLAND, WA, 98034 Phone: (253) 736-2980 Phone: (253) 736-2980 Expiration Date: 10/9/2018 DESCRIPTION OF WORK: REFRESH LOBBY AND INSTALL NEW SELF -SERVE ORDER AND PAY KIOSKS (FURNISHED BY OWNER). SELECTIVE DEMO AT LOBBY AND RESTROOMS. REMOVE PLAYSPACE INCLUDING CLIMB ON TOY AND SAFETY FLOOR. INSTALL NEW COUNTERS, FLOORING, WALL TILE, WALL COVERINGS, COUNTERS, STORE FRONT, LIGHTING, ACCOUSTICAL CEILINGS Project Valuation: $220,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $4,394.29 Occupancy per IBC: Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: 1/atIL Date: 9 `J 1 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ItOt ix / l Date: 7-S Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 0 0 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by. the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: Maintain fire extinguisher coverage throughout. 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 18: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1013.1) 19: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit hardware. (IFC 1010.1.10) 20: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1013.6.3) 21: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1008.3.5) 22: Maintain a 4 foot clear space around the sprinkler riser(s) for emergency access. (NFPA 25) (City Ordinance #2436) 23: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 25: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 26: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 28: Dedicated fire alarm system circuit breaker(s) shall be equipped with a listed breaker locking device. (NFPA 72 (10.6.5.4)) 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 30: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 32: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING 0 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. DI��021 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: ClOtt --Cx) C10 Site Address: /5c2.10 ., n ) V/)a honol Q Suite Number: Tenant Name: ` - u) . OL uoici) PROPERTY OWNER Company Name: Se Oct r 0a t LAI J Name: b G.0/1tl1462 /' . n vtit (.. v$ `t��j Name: C L e: d � cc Lv. fr Address: /2 151 1 1 1541. hog_ (�Slaa3 N� /d ,,��� City: 1 fiLk vi )pi° Zip!i )' CONTACT PERSON — person receiving all project communication Company Name: Se Oct r 0a t LAI J Name: b G.0/1tl1462 /' . n vtit (.. v$ `t��j Address:U1©3$' S` 4M�ls�-T.�/ i City: 7C_Y/ML7O State: Lt3 ft Zi / Address: 703 g S, a -a -8`r Phone:as s 1.3(.o oi9$ D City: State: uo p Zip: ci 03 Email:G 1G.0�' M & db--ac--4 (.z ' ' GENERAL CONTRACTOR INFORMATION Company Name: Se Oct r 0a t LAI J Company Name: br6G Q Address: n o _ j _, '-y Address: 703 g S, a -a -8`r / City: State: uo p Zip: ci 03 Phone: g S 3- 7.5 / Fax q go Contr Reg No.: 0 @ t)j /=C Date: 4X49 10161/20 Tukwila Business License No.: City: H:\Applications\Forms-Applications On Line \2011 Applications\Pcrmit Application Revised - 8-9.11.docx Revised: August 2011 bh 17 Floor: New Tenant: ❑ Yes 114.No ARCHITECT OF RECORD Company Name: Se Oct r 0a t LAI J Architect Name: 101 G t/ ' ), Address: n o II, s _ad, £ r city:- Vm+ �,�,),_�h 1 l.A1 tal-- iii5, Z:i • `1 , l1 Phone: .75 (_ 3 _ 444 t. . Email: 1 nth iti)i SeUa n sot W -I-1 OM Lai ENGINEER OF RECORD Name: r Company Name: Address: / 2) Engineer Name: City: l y ,�% Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: r mC DmtikJ-act Address: / 2) E --i j 1) 3" /i - n N r (\-- City: l y ,�% , Lig State:l Zip:ggBit Page 1 of 4 .1 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ .220, 0 D D. Existing Building Valuation: $ t I n'1 t11( O�e.'le Describe the scope of work (please provide detailed information): /Ir" LOb t S -(� gm -A.)0 — Sw — yd�mv .paw 124—os.aL-RA.rlhl Our J Se.t.e4-I Kt_ demo 0 [01 61-vv-or44. p l a Spe.L, e Ilt�b-on 40(-3.,r- s 4.14.100r:Sns�-E0,L1 ru- r c431.11. -A.4 •5 4 l o-oYi,)) WcW. ±a -c) v3ca. lir 3, c.ott,n 4.e✓S, '3+04_4 oi' (, h j ,a.GcO 4 4-1 Cud ce i Id Kgs Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): , Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ' No If 'yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Materia! Safe ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forth-Applications On Line \2011 Applications\ermit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure, New Type of Construction per IBCAf, Type of Occupancy per IBC 1 s` Floor � 4-g D �J `T�j IOW— W- (�� �` ,�n eat i( y(� 6 .(aQ 2"d Floor �v 3rd Floor A)) PC Floors thru Basement d )� pi /� r 1 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): , Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ' No If 'yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Materia! Safe ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forth-Applications On Line \2011 Applications\ermit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: )D(/., Print Name: X U I CA -41 Mailing Address: loss J H:Wpplications\Forms-Applications On Line \2011 Applications \Permit Application Revised - 8-9-1 I.docz Revised: August 2011 bh Date: " / J! Day Telephone: 3 13 (a -g9 O u)f q Ro3 City State Zip Page 4 of 4 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK Ir} PAID $4,394.29 D17-0214 Address: 15210 INTERNATIONAL BLVD Apn: 0043000090 $4,394.29 DEVELOPMENT $4,265.18 PERMIT FEE R000.322.100.00.00 0.00 $2,582.23 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,678.45 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $129.11 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R12084, $129.11 $4,394.29 Date Paid: Wednesday, August 09, 2017 Paid By: DB GENERAL CONTRACTORS Pay Method: CHECK 17559 Printed: Wednesday, August 09, 2017 3:41 PM 1 of 1 CiiiiiWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 17-02>9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of inspection: AIA-1--i Address:Date Called: `5�6 /rr R/ y7'w4j?4 Special Instructions: 4 V/L-D/M& f71Y4-L Date Wanted: // j // � dam'/ 7 Ca.m p.m. Requester: Phone No: Z062— 36g/- 363 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6K -_>l ltd. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 f i7 -off ! L Project: /HA/4a s Type of Inspection: 672 P7.tl., , e/' -N, - Address: /52/0 77/1B Date Called: Special Instructions: Date Wanted: `_ ?_/ a.m� Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: k 50 -TE/ mD L/NL 0eK-a,�G ' z-IG-A7177AG Inspector: Date: // ? i 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DO -cat if Project:, Mel i 5 Type of Inspection: 62fot/NG Address: /,5/1) /,jl77 , 1.i/V/ Date Called: Special Instructions: Date Wanted: //� �7 Ca. .m p.m. Requester: Phone No: FIS Approved per applicable codes. Corrections required prior to approval. COMMENTS: o< 0 - a-1�& (''° /" c)-- £Xi571 Inspector: 05 - Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b\--? \7 -'- Za3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: MC' 00v\\ ,_C Type of Inspection: , SQL., Cystc-c—ki`or• Address: , 5 -z Suite #: 6 ,.CIJI,,,c)lcksz Contact Person: -r-f,:„ Special Instructions: Occupancy Type: Phone No.: 4pproved per applicable codes. Corrections required prior to approval. COMMENTS:l Sprinklers: \C f c- 1 6 ,.CIJI,,,c)lcksz Monitor: Pre -Fire: SCZ r , 4-c. C t)\rtt Occupancy Type: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4.:... Date: \\\9‘i\-1 Hrs.: \ .- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER b INSPECTION RECORD Retain a copy with permit 1,>"7---4214- Type of Inspection. /7- - c► _21,4.2 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: mt N Type of Inspection. Address:f 22 Suite #: /5l./() �f Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: . Pre -Fire: k I'D 66Y& - 1 -pr Occupancy Type: ) /.-.r 0' (-41 r cr-N1 / p { 1 vE J 7 ; - i) A-(2dl ftYZ r i N& $ -6-- AgeD t -ib fipc- - ^ ii -1)1) E) of C./Ai2-s71Jr eP$ oven 4 flIrw FM- c OY& Y2- l r /^' A - Needs Shift Inspection: - Sprinklers: Fire Alarm: Hood & Duct: Monitor: . Pre -Fire: Permits: Occupancy Type: Inspector: a-4— Date: WV .... Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 August 25, 2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development DIANE MULLINAX 7038 S 220TH ST KENT, WA 98032 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0214 MCDONALD'S - 15210 INT'L BLVD Dear DIANE MULLINAX, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PLANNING DEPARTMENT: Lindsay Brown at (206)-433-7166 if you have questions regarding these comments. • Your project description states that you will remove the play space. If proposing changes that impact the exterior appearance of the building, please submit elevations and a site plan. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, "3:),.(71) Bill Rambo Permit Technician File No. D17-0214 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 CPFRM!T CaORD COPY CI PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0214 DATE: 08/14/17 PROJECT NAME: MCDONALD'S SITE ADDRESS: ' . 15210 INT'L BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ire Prevention onAVIO tlItiii, sV rill) V \t1'1 Pubic Works 113 Structural Aief ,19-16t111 Plan ng Division 844-17 Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/15/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews DUE DATE: 09/12/17 ❑ Approved with Conditions Notation: Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: S-)—SN—Y7 Departments issued corrections: Bldg 0 Fire ❑ Ping re— PW ❑ Staff Initials: 12/18/2013 DB GENERAL CONTRACTORS P'o" Home Espanol Cow act !Search L&I A-Ztnd x flop Page 1 of 2 My 1.&t Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of "Labor & Industries DB GENERAL CONTRACTORS INC Owner or tradesperson Principals BEDNARIK, DEWAINE, PRESIDENT 1ioinq business as DB GENERAL CONTRACTORS INC WA U131 N. 602 650 709 7038 SOUTH 220TH ST KENT, WA 98032 253-736-2980 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no DBGENGC943O9 Effective ---- expiration 09/29/2006-10/09/2018 Bond DEVELOPERS SURETY & INDEM CO Bond account no 743855C $12,000.00 Received by L&I Effective date 09/29/2006 09/28/2006 Expiration date Until Canceled Insurance Western National Assur Co $1,000,000.00 Policy no. CPP114887000 Received by L&I Effective date 08/21/2017 09/28/2016 Expir'Ertlon date 09/28/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602650709&LIC=DBGENGC943O9&SAW= 9/5/2017 DB GENERAL CONTRACTORS IM Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums: L&I Account ID Account is current. 122,683-00 .................................. Doing business as DB GENERAL CONTRACTORS Estimated workers reported Quarter 2 of Year 2017 "21 to 30 Workers" L&I account contact TO / DALE MCMASTER (360)902-5617 • Email: MCMS235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602650709&LIC=DBGENGC943O9&SAW= 9/5/2017 18, 2017 — 3:28pm csantiago 0' v ai c 0 0 d 0 0 0 I 0 LJ - 0 0 U-1 0 11- 1- 11.1 1— w 0) a) -c 0 z 0 .6 a) 3 0 0 0 a) 0 0 0 to 0 0 rn 0 a) fn rri fn E rn ori REFERENCE FLOOR PLAN MINO� \4� RFMODEL WAST .REGI4f� EO REVISIONS DAWI\G \3X T1.0 'COVER SHEET D1.0 DEMOLITION FLOOR PLAN BUILDING INFORMATION ADDRESS STATE SITE CODE: STREET ADDRESS: CITY: COUNTY: STATE: STUCTUE TBD UTILITIES SCOPE OF WOR INTERIOR ALTERATIONS TO EXISTING 1 STORY BUILDING SYMBOL LEGEND: 0 DINING ROOM 101 x L_ _J SECTION TAG DETAIL TAG ELEVATION TAG DRAWING TITLE DOOR TAG ROOM NAME & NUMBER PARTITION TAG KEY NOTE TAG ce S 152nd St S 152nd St MetroPCS Authorized dealer, Bakaro Mali MoneyGrarn Taberak Minimarket & Halal 1 Taqueria El ,i?, Rinconsito of Sea Tec w Western Union S 154th St S 1 54th St Sbuthcenter Blvd Southcenter Bivd 3aoNortn Qar 8'RV Rental Chevron Tukvlila Sauthcentg 046-0005 15210 PACIFIC HWY W TUKWILA KING WASHINGTON D1.2 DEMOLITION CEILING PLAN A1.0 FLOOR PLAN A1.1 REFLECTED CEILING PLAN A1.2 ENLARGED FRONT COUNTER PLAN, ELEVATIONS AND COUNTER SECTIONS A1.3 KIOSK CUT SHEETS seven MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-567-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS A1.4 KIOSK AND TABLE LOCATOR DETAILS A1.5 FRONT COUNTER DETAILS M1.2 DUCTWORK PLAN M4.0 GENERAL NOTES M4.1 SCHEDULE E1.0 SYMBOLS LIST, ONE LINE AND NOTES E1.1 FLOOR PLAN — POWER E2.0 FLOOR PLAN — LIGHTING E3.0 GENERAL ELECTRICAL NOTES E4.0 ENERGY CODE E COPY Permit No.oti- OL Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize . the violation of any adopted code or ordinance. R of approved Field Copy and conditions is acknowledged: Date: 9`'SH City of Tukwila BUILDING DIVISION REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Euilding Division. NOTE: Revisions will re ;uire.a new plan submittal and may include additional plan review tees. SEPARATE PERMIT RrQUiRED FOR: GirMachanica1 @'Electrical @'Plumbing (VGas Piping Ci:y of Tukwila SU31_I'`I1`4^t DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 292017 . h -J City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER NO. I DATE DESCRIPTION PROJECT NO.: si 1 t�Y k its 1 � °d 1 art 1 CS' 1 iii 1 �wY 1 iy✓ q 1 �? I r I I Y I SEAL DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR m McDonald's USA • LLC These drawings and specifications are the ; confidential and proprietary property of McDonald's USA, LLC and shall not be bopied or reproduced without written authorization. The.. contract documents wire prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuseon another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE COVER SHEET SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 DRAWN BY: CS' REVIEWED BY: NJ NATIONAL STORE # 00472 ®i LOCATION MAP <6\a> SHEET NUMBER .0 Architecture AtiOD MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367.4445 1011401141 1 1 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com www.sevansolutlons.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS DINING QUEING posztiottl 1 1 husgstaggi 1 1 L9f1 tagoeurso L._ -.._ tvIDP Fir, AP -,:i DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION 9pm csantiago 0 N c0 > rn v vi 0 0 0 0 0 I 0 0 0 LU 0- 0 w 1) t 0 z 0 0 rn fn 0 0 0 0 a) 0 0 E 0 0 0 0 0 a) f1) N E fn DEMOLITION FLOOR PLAN 1.y 3/16" = 1'-O" PREPARED FOR LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 DEMOLITON KEY NOTES ("CORE 16" SCOPE) NOT ALL KEYNOTES APPLY 'x' DENOTES KEY NOTE NUMBER BELOW 1. EXISTING EXTERIOR WALL TO BE REMOVED, SEE A1.0 FOR MORE INFORMATION. 2. REMOVE EXTERIOR LIGHTING & SAVE CIRCUIT FOR REUSE. 3. SELECTIVELY DISMANTLE STOREFRONT, GLAZING & MULLIONS AS APPLICABLE. 3a. REMOVE WINDOW ASSEMBLY (TO BE REPLACED W/ NEW WALL). 4. REMOVE EXTERIOR DOOR. 5. REMOVE EXISTING BUILDING SIGNAGE (TO BE REPLACED). 6. REMOVE EXTERIOR WALL FINISH. 6a. REMOVE WALL TILE & PATCH WITH STUCCO & PAINT. 6b. REMOVE STONE VENEER & PATCH WITH STUCCO & PAINT. 7. REMOVE CANOPY/TRELLIS. 8. REMOVE AWNING, PATCH STUCCO FLUSH WITH EXISTING & REPAINT FACADE AS INDICATED. 9. REMOVE EXISTING INTERIOR PARTITION (NON-LOADBEARING). 10. PREPARE ALL EXISTING INTERIOR PARTITIONS FOR NEW WALL FINISH. 11. REMOVE EXISTING INTERIOR DOOR, FRAME, THRESHOLD, & ASSOCIATED HARDWARE. 11a. REMOVE HARDWARE ONLY. 11 b. REMOVE THRESHOLD ONLY. SHEET TITLE LEGEND 11c. REMOVE DOOR ONLY. 12. REMOVE EXISTING FLOOR FINISH. 13. REMOVE FRONT SERVICE COUNTER (COORDINATE WITH INTERIOR "DECOR" DRAWINGS). 13a. REMOVE LATTICE PARTITION & REFINISH CBB WALL. 14. REMOVE PLUMBING FIXTURES (MAINTAIN EXISTING CONNECTION FOR RE -USE). 15. REMOVE TOILET ROOM ACCESSORIES. 16. REMOVE TOILET PARTITION. 17. REMOVING EXISTING FURNITURE. PATCH FLOOR SMOOTH TO RECEIVE NEW FLOORING. 18. EXISTING KITCHEN EQUIPMENT TO REMAIN (NIC). 19. REMOVE EXISTING INTERIOR RAILINGS- PATCH FLOOR SMOOTH TO RECEIVE NEW FLOORING. 20. PARTIALLY DEMO & PATCH EXISTING GYPSUM BOARD CEILING AS REQUIRED. 21. REMOVE CEILING (SEE 21a, 21b & 21c BELOW). 21a. REMOVE CEILING (ACOUSTICAL CEILING TILE/SUSPENDED GRID & FALSE HEADERS/SOFFITS. 21b. REMOVE CEILING (SUSPENDED GYPSUM WALL BOARD/PANEL CEILING SYSTEM IN e ITS ENTIRETY). 21c. REPLACE ACOUSTICAL CEILING TILE & PAINT EXISTING SUSPENDED GRID SYSTEM PER DECOR DRAWINGS. 21d. REPLACE STAINED & DAMAGED ACOUSTICAL CEILING TILES AS NEEDED. 22. REMOVE INTERIOR LIGHTING. (COORDINATE WITH ELECTRICAL DRAWINGS/NOTES/SPECIFICATIONS). REUSE CIRCUIT FOR NEW LIGHTING. 23. ADJUST HVAC DIFFUSERS AS APPLICABLE WITH NEW CEILING DIFFUSERS. 24. REMOVE INTERIOR LINEAR DECORATIVE LIGHTING (SEE ELECTRICAL). 25. REMOVE CEILING FANS (N/A). 26. REMOVE/SALVAGE SPEAKER & ASSOCIATED WIRING (TO REMAIN, COORDINATE W/ ACM). 27. REMOVE ILLUMINATED EXIT SIGN (TO BE REPLACED W/ NEW). 28. REMOVE EMERGENCY LIGHTING (TO BE REPLACED W/ NEW). 29. REMOVE/SALVAGE SECURITY CAMERA & ASSOCIATED HARDWARE (COORDINATE W/ ACM). 30. REMOVE DECORATIVE CEILING ELEMENTS. 31. REMOVE/RELOCATE MOTION SENSORS WOR DOOR SENSORS (COORDINATE W/ ACM). 32. REMOVE EXISTING ROOFING SYSTEM AS REQUIRED. 33. EXISTING MECHANICAL EQUIPMENT TO REMAIN. 34. EXISTING ROOF DRAIN/LEADER TO REMAIN. CLEAN & PAINT AS REQUIRED. 35. REMOVE EXTENDED PARAPET. 36. REMOVE EXISTING MENUBOARD EQUIPMENT & FINISHES AS PER DECOR DRAWINGS. 37. REMOVE EXISTING COLUMN. 38. REMOVE GABLE FACED PARAPET & ASSOCIATED APPURTENANCES. 39. PREPARE EXISTING EXTERIOR WALL TO RECEIVE NEW FINISH. 40. REMOVE EXISTING MANSARD OVERHANG PROJECTION, ALONG WITH ANY ASSOCIATED RECESSED OR SURFACE MOUNTED LIGHTS IN/ON THE MANSARD (TYP. ALL SIDES). 41. DRIVE-THRU HEARTH (OPTIONAL). 42. EXISTING DRIVE-THRU TRANSACTION WINDOWS TO BE REMOVED, SEE SHEET A1.0 FOR MORE INFORMATION. 43. EXISTING PIPE BOLLARD TO REMAIN. CLEAN & PAINT AS REQUIRED. 44. EXISTING MENU BOARD VALANCE TO BE REMOVED. 45. EXISTING PLAYPLACE TOY & SAFETY FLOOR TO BE REMOVED. 46. EXISTING KITCHEN WALL FINISH TO BE REMOVED, PREPARE TO RECEIVE NEW FINISH. 47. REMOVE EXISTING FREEZER/COOLER END PANELS AND DOORS FOR EXPANSION. EXISTING PARTITION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 292017 DEMOLITION FLOOR PLAN C = 7ZM EXISTING PARTITION TO BE EMOVED City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2097 PERMIT CENTER SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 DRAWN BY: CS REVIEWED BY: NJ NATIONAL STORE # 00472 SHEET NUMBER D 1 0 • Architecture July 18, 2017 3:29pm csantiago on -0 tri 0 LO 0 0 0 0 a_ IJ - 0 s 0 U rn 0 2 i.L 0 fn 0 0 v a) vi rn r i k, n tYl-;n AP-- 1 L - I AP -?AP i OEP 0 Fl OEP I _1 I 1 1 _ I__ 1 __r_ 101 1 101 - 1 1 --1--+ =1 _-1--y-- - -- 1 1 1 1 1 1 1 1 1 1 - 1 -- --1---14__1 - 1__ 1 I 1 1 „1 1 0 1 1 1.111141111101113rer mop ems al.. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - -1---1-- --_Jr- -- --1 I 1 1 1 1 __1-_._4__1--_1__4__1__ _..}__,1,._._1__.}__- I1-1__.L__L_1__L--Ir--L---_.1__l 1 1 r--r--r--1-- -- - - -- - - -- - -1---i 11 - 1 __ - I - I --1 - i - I -- - 1 - 1-- I IIrY r-r't r -r -t r-rrt __L_ -1 I 1 1 1 1 1 1 1 1 1 1 1 1�-�--�- ...,_-I- I -I--,..,-1 - -1---1 1 101 I 1 01 1 I i i--4--4-- - n __-- I 11111111* MOM 0 0 oC 1 1 1 1 1 1 1 1 -- t-- i --i - i-- ,_--1__.1.__I-_�__+ 101 101 11 1 1 1 I1 1 ' 1 - 1-- --1 L- -- - -- --4. __r -'t j 1 1 1 1 I 1, i0 , I 1 I I- i- -i '- I--1 - I- I- -r 4_4. -- -1- -- I j 1 1 11 I I I I I L_1__L_J__ __ L f 4_ --- 1 I 1 I 1 I 1 1 1I 1 1 0 1 I I I I 1 I I I I 11 DIN c$ 1 ____i __ _ __ -1-_.1-_.1._-1--..f� 1 1 1 1 1 11 I 101 1 1' I 1 1 1 1 1 I 0 1 I 1 1 1 111"_-I�i_�1---I-_ _i --1' - f-_}._ - -H. . 1 0 1 I 1' 1 1 1 0 1 1; 1011I0I 11Ifo1I1 H---i-4--1---H1 I I 1 1 L.L_-1 1 1 1 1 1.1 . I I 1 IISL_ 1 1 1 -71:, I �1-71-1 ;n1 1I I trl;tl0 1 QEIN0LittH:00ttH1L_J__L_ 1 1 101 1 - 1-1---- -- - 11 1- 1- -F-1 101 1 1 1 11 11 1 , r-1-- ---" - -- I I 1 4-4--- 1 1 0 1 1 1 0 1 1' L - #---1-- -- - -- --r r--r-1-r- 1 -- 1 1 1 1 1 1 1 i I' I I ii0 9tf.-b--Fi L_121__L_ 1 0 L --1--.1--L- -= 11 �_ $ 1 1 101 1 1 1 1 1 1 1 1 1 1 1 -1-- /1-- 1-1---1--'1---1--4-11 1 I I I 1 1 I I 1 I lel 0 I 1 1 1 I I I--4--4-- �-, _ ,v --4---1--4-- --II--4-1 v--1--L--rl _ 1. j 1 1 0 I I x' $ 0 1 1 10 �` X'$ 1 i�r Li --1--L--4.--141 I 1 I �- :a, --r--t---r-- I 11�_ - 1- i1 1 1 1 0_ 0_ 0 0 1 1 1 I r--r--t-- 1 1 �-u- T s -� I -L-141 1 1 1 1 1 1 1 1 1 1 1I ----T--1---r--1---1 1 1L-1--1--1----L_L.--1--L- - 101 1 1 '-1-- --r-T- -- - - - 1 1 1 1 1 1 1 1 1 •,,,1-- --1 - -- - - --{, 1' I -- I I- I -- I- 1 '� I--17 1 1 1 1 1$ 1 1 I' - I - I --r--r �- I -- I - I - I -- 101 1 1 1 0 1 1 I I I I I I-1 T 1-'t T---------1---�-- , 1 1-- \\\44 - - 1--�---1- ` Y i- � ��'�, 1 I � � i � 119 I I I I 1 -I I --1 -I - I -- 10 -r � r.� 0 `� 0 0 01 1 0 0 1 I I 1 I 1 1 I ----I---1--.1---1---1--+--1---E- 1 I 1 I I 1 -i 3:29pm csantiago 0 N LO 0 0 0 I 0 0 0 w CL 0 Li w 10 -c 0 z 0 0 rn a) 0 E 0 ) 0 0 E 0 \\smss.sevansolutions r FiDP(�` -1 LP i Ar --2 AP --. FIRST FLOOR - FLOOR PLAN 3/16" = 1'-0" OEP OEP 3'-4" 2' IP 11 2'-2" (0 MIK maw non MIN NINE 18'-3" 0 _5 QUARRY FLOOR TILE TILE` i 0 0 a 0 N rn t — DINING _J n 101 uY I 1 RQ 1 DINING 101 MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: PROJECT NO.: 046-0005 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com wwW.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS DATE DESCRIPTION NATIONAL STORE # i:. ° e } ,yyyy Y$S 1 1 1 + 1 1 5 1 I tP s. NO. I I I I DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. SIMPSON STRONG—TIE "HTC4" ® 48"O.C. CONT. TOP PLATE LATERAL BRACING TO STRUCT. ABOVE 4-0" 0.C. 1/2" GYP BD, 1/2" CEMENT BOARD OR PLYWOOD BACKUP EACH SIDE AS INDICATED ON FINISH SCHED BOTTOM 12" OF BACKUP TO BE CEMENT BOARD — MIN. 1/2" ABOVE SLAB CLG AS SCHEDULED FLOOR AS SCHEDULED INTERIOR PARTITION 3/4"=1'-0f1 STRUCT. MEMBER OR STUD SPANNING BOTTOM CHORD ® 4'-0" 0.C. CONT. 2X FIRESTOPPING AT EXTENT OF BACKUP (TYP) METAL STUD PARTITION TYPE: "MA" = 3 5/8" SPACING: 16" 0.C. STUD GUAGE: LOAD BEARING: 18 NON—LOAD BEARING: 20 WOOD STUD PARTITION TYPE: ALL PARTITIONS TYPE 'A' UNLESS NOTED OTHERWISE "A" = 2x4 "Al "= 2x4 W/BATT INS. "A2"= SEE 8A/A4.2 "B" = 2x6 "B1 "= 2x6 W/BATT INS. "C" = 2x8 "Cl "= 2x8 W/BATT INS. STUD SPACING: 16" 0.C. KEY NOTES 2 5 7 NEW FRONT SERVICE COUNTER NEW 2—SIDED SELF SERVE KIOSK. PROVIDE POWER & DATA PER KIOSK MANUFACTURERS REQUIREMENTS. ALL KIOSK CONTROLS & OPERATING MECHANISMS SHALL BE LOCATED BETWEEN 15"-48" A.F.F. 30"x48" CLEAR FLOOR AREA (TYP.) NEW TABLE LOCATOR SYSTEM PROVIDE AND INSTALL NEW TILE FLOORING TO MATCH EXISTING TILE IN DINING AREA TO EXTENT SHOWN. DROPPED SOFFIT ABOVE — SEE REFLECTED CEILING PLAN. DECOR WALL — VERIFY SIZE AND PLACEMENT WITH DECOR PLANS GENERAL NOTES 1. INTERIOR DIMENSIONS ARE TO FACE OF INTERIOR WALL BOARD 2. SEE 2/A1.0 FOR INTERIOR PARTITION TYPES. INTERIOR PARTITIONS ARE TYPE 'A' UNLESS NOTED OTHERWISE. 3. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED IN PACKAGE OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST PERMA—SIGN 1-800-214-8765 9292 1ST ST., BOX 588 www.forrestpermasigns.com NEW ROCHELLE, NY 10802 4. MAXIMUM OCCUPANCY SIGN TO BE POSTED PER LOCAL CODE. SIGN FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 5. GC TO COORDINATE ALL REQUIRED BLOCKING FOR WALL HUNG EQUIPMENT, SHELVES, ETC. FOR PROPER INSTALLATION HEIGHTS. 6. KNOX BOX TO BE INSTALLED PER LOCAL CODE AS REQUIRED. MODEL AND LOCATION TO BE COORDINATED WITH FIRE MARSHALL. 7. REFER TO FINAL DECOR DRAWINGS FOR FINAL FRONT COUNTER & SELF SERVE BEVERAGE WALL FINISHES. (FINISHES SHOWN FOR BIDDING PURPOSES ONLY.) 8. PROVIDE ADDITIONAL MISCELLANEOUS FRAMING WITH MINIMUM CONNECTIONS TO EXISTING STICK—BUILT FRAMING AS REQUIRED BY CODE. 9. FOR MORE INFORMATION & DETAILS ON KIOSKS REFER TO SHEET A1.1 10. FOR MORE INFORMATION & DETAILS ON TABLE LOCATOR REFER TO SHEET A1.4 11. COORDINATE ANY NEW DESSERT EQUIPMENT LOCATION WITH OPERATOR. 12. FOR MORE INFORMATION & DETAILS ON FRONT COUNTER REFER TO A1.5 13. COORDINATE TILE INSTALL AT NEW COUNTER CUT WITH DEMO. SEE SHT D1.0. LEGEND X qTrAleretn PARTITION TYPE TAG SEE 2/A1.0 DOOR TAG — SEE DOOR SCFE6{g FOR CODE COMPLIANCE KEY NOTE APPROVED EXISTING PARTITION AUG 292017 NEW FULL HEIGHT PARTITION City of Tukwila BUILDING DIVISION NEW PARTIAL HEIGHT PAFRP6'D CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE FLOOR PLAN SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 DRAWN BY: CS REVIEWED BY: NJ NATIONAL STORE # 00472 SHEET NUMBER A1.0 Architecture " r7RR" +Ij SSBB NOT SHOWN (7 INTERIOR ELEVATION - POS SCALE: 3/8" = k1•_2.) NTS 10" (HEIGHT A.F 0 J 0 0 COVED QUARRY TILE BASE TILE MOUNTED TO PLYWOOD QUARRY TILE J l MODULAR FRONT COUNTER FURNIHED & INSTALLED BY 1S11 TIMBER TILE CUT TO 4" & USED AS BASE DINING ROOM TILE AS SCHEDULED MODULAR FRONT COUNTER SECTION A1.2 NTS 7 — 3:30pm csantiago 0 ao 3 sevansolutions.com\DGFileroom\DGDesign\McD Northwest EOTF—MRP\EOTF\046-0005 Tukwi nII 1- 046-0005 DATE ISSUED: 07/07/17 [146$'] CS [361 NJ NATIONAL STORE # 00472 J J 11 11 N N II II II II 1 N 1 1 RIFY CEILING HEIGHT -'I G II f/J1�j.�— I'' L -- —— — — — — —� ' __II_ -TO m �u 11_1,711 _L_ 771 liarFrnTWHfnr I JirHurn hu ut i -u u u rn u1`I�rru uun FFf uauttrn ifraaBnr t ( V.I.F. 1- - O L 2 CD o� C L LTI ,c,./(z., C alme \�� Y RAISED CEILING 9'-6" N a' v.I.F. i �—- I� I1 � -q 'I IN 1 LL iii -J` C > L .� \ cr wN _ — — I \ — I I I I I I o I I o I I I — J N I I iv I I 1 _ _N I I I I I _ 1 JJ J i i `— SSBB NOT SHOWN (7 INTERIOR ELEVATION - POS SCALE: 3/8" = k1•_2.) NTS 10" (HEIGHT A.F 0 J 0 0 COVED QUARRY TILE BASE TILE MOUNTED TO PLYWOOD QUARRY TILE J l MODULAR FRONT COUNTER FURNIHED & INSTALLED BY 1S11 TIMBER TILE CUT TO 4" & USED AS BASE DINING ROOM TILE AS SCHEDULED MODULAR FRONT COUNTER SECTION A1.2 NTS 7 — 3:30pm csantiago 0 ao 3 sevansolutions.com\DGFileroom\DGDesign\McD Northwest EOTF—MRP\EOTF\046-0005 Tukwi nII SSBB NOT SHOWN INTERIOR ELEVATION A1.2) NTS SCALE: 3/8" = 1'-0' SCHLUTER QUADEC 010AE AT OUTSIDE TILE CORNER MODULAR FRONT COUNTER PICK—UP (DASHED IN FOREGROUND) 5 COVED QUARRY TILE BASE TILE MOUNTED TO PLYWOOD QUARRY TILE l J MODULAR FRONT COUNTER FURNISHED & INSTALLED BY ISI TIMBER TILE CUT TO 4" & USED AS BASE DINING ROOM TILE 7-- AS SCHEDULED PICK-UP SHELF SECTION 6\1.) NTS 3'-4" 2' - ,, 8'-7" MODULAR FRONT COUNTER FURNISHED & INSTALLED BY DECOR COMPANY. 2'-3" QUARRY TILE FRONT COUNTER PLAN FLOOR TILE 0 ¢ I O ow 1- 0 MODULAR FRONT I o COUNTER FURNISHED ") I & INSTALLED BY DECOR COMPANY. PICK—UP SHELF 6 ma_ 1 0 0 I 03 1.2 1 1 /2" = V-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734.367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS V L, DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR In McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of. McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. RECEIVED CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER 1/2" TEMPERED GLASS W/ ETCHED MCCAFE LOGO ON FRONT SIDE OF GLASS. MITER CORNER, CENTER IN LOW WALL. SOLID SURFACE WALL CAP CBB RETURN WALL Sc GLASS 1/4" SHIM SPACE FOR GLASS, BLOCKING TO SUPPORT SOLID SURFACE TOP SOLID SURFACE ON DINING ROOM SIDE OF WALL City of Tukwila BUILD.) EQ. EQ. SEE DECOR FOR FINAL FINISHES. 2� CBB WALL SECTION C\1 2 1/4" PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE ENLARGED FRONT COUNTER SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 [146$'] CS [361 NJ NATIONAL STORE # 00472 J J -'I G II f/J1�j.�— I'' L -- —— — — — — —� ' 771 VERIFY CEILING HEIGHT ( V.I.F. O L o� C L ,c,./(z., C alme \�� L N L i �—- I� I1 � -q 'I IN 1 SSBB NOT SHOWN INTERIOR ELEVATION A1.2) NTS SCALE: 3/8" = 1'-0' SCHLUTER QUADEC 010AE AT OUTSIDE TILE CORNER MODULAR FRONT COUNTER PICK—UP (DASHED IN FOREGROUND) 5 COVED QUARRY TILE BASE TILE MOUNTED TO PLYWOOD QUARRY TILE l J MODULAR FRONT COUNTER FURNISHED & INSTALLED BY ISI TIMBER TILE CUT TO 4" & USED AS BASE DINING ROOM TILE 7-- AS SCHEDULED PICK-UP SHELF SECTION 6\1.) NTS 3'-4" 2' - ,, 8'-7" MODULAR FRONT COUNTER FURNISHED & INSTALLED BY DECOR COMPANY. 2'-3" QUARRY TILE FRONT COUNTER PLAN FLOOR TILE 0 ¢ I O ow 1- 0 MODULAR FRONT I o COUNTER FURNISHED ") I & INSTALLED BY DECOR COMPANY. PICK—UP SHELF 6 ma_ 1 0 0 I 03 1.2 1 1 /2" = V-0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734.367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS V L, DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR In McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of. McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. RECEIVED CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER 1/2" TEMPERED GLASS W/ ETCHED MCCAFE LOGO ON FRONT SIDE OF GLASS. MITER CORNER, CENTER IN LOW WALL. SOLID SURFACE WALL CAP CBB RETURN WALL Sc GLASS 1/4" SHIM SPACE FOR GLASS, BLOCKING TO SUPPORT SOLID SURFACE TOP SOLID SURFACE ON DINING ROOM SIDE OF WALL City of Tukwila BUILD.) EQ. EQ. SEE DECOR FOR FINAL FINISHES. 2� CBB WALL SECTION C\1 2 1/4" PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE ENLARGED FRONT COUNTER SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 DRAWN BY: CS REVIEWED BY: NJ NATIONAL STORE # 00472 SHEET NUMBER Al .2 Architecture 18, 2017 — 3:30pm csantiago >, 3 \\smss.sevansolutions.com\DGFileroom\DGDesign\McD Northwest EOTF—MRP\EOTF\046-0005 Tukwila, WA\A1 _Plans.dwg 11 'tF: Konstrution 4-tti3nc'1c r€`h Kiosk placement. /side the 12T-0" customer service area 1'dhe r -e the typical decor wall is located MRP/EOTF Standards: Kiosk placement — 1O'-0" customer service area where the typical decor wall is located Take into account which entrance is the main entrance Make kiosks immediately visible upon entry Position kiosks along main customer path before they reach the traditional front counter, visually interrupting, their journey Avoid conflicts with customer congestion at other order points Provide sufficient space for larger groups, families and universal design accessibility Ensure path from kiosk to service area is clear Consider privacy of those dining when kiosks are adjacent to seating Leverage decor to help customers navigate through the space Cluster kiosks close to one another to optimize kiosk coach interaction with customers FN • PLAN VIEW • Typical kiosk face quantity (4 faces), final quantity per restaurant to be determined by McDonald's Operations team • 12' clear dimension highly recommended between front counter and kiosk *Existing conditions to be considered • See table locator guideline on page 5 for placement • Power from above (with standard ceiling height) If ceiling is greater than 10'6" contact USRD Project Manager, see kiosk cut sheet for additional electrical information • Consider size of base plate for clearance when angling a kiosk against a wall/partition • Kiosks may be turned on an angle to increase screen visibility • Double sided or single sided kiosks can be free floating or angled • When space allows, this solution is the ultimate in interrupting customers and ideal when large groups are expected to order together • Ensure adequate circulation around free floating kiosks • Ideal when a large quantity of kiosk faces are required M1� SIDE ELEVATION X MIN 1 FRONT ELEVATION y 3'-0' A w� vv zz 00 O 32' x48' CLEAR SME IN FRONT QF KIOSK FACE tic Note: Clear areas cannot overlap PLAN • Typical kiosk faceuantity (4 faces), final quantity per restaurant to be determined by McDonald's Operations team • 12' clear dimension highly recommended between front counter and kiosk *Existing conditions to be considered • See table locator guideline on page 5 for placement • Wall finish behind kiosk to coordinate with decor • Power from above (with standard ceiling height). If ceiling is greater than 10'6" contact USRD Project Manager, see kiosk cut sheet for additional electrical information • Customer queues may form and create congestion with other order points. Use this configuration only when there is sufficient clear space in front of kiosk • Wall or partition not necessarily required behind kiosk, single sided configuration acts as a partition • Single sided kiosks may be angled slightly (100-151 to provide better screen visibility • Work well side by side with a 5' wide partition/wall behind CHANNEL FOR —► — a' 's—' CONDUIT DATA CABLES FOR POWER 95.Oin 25.7in ►� 1 29.2in 1 11 11 r. 42.7in 21.6in FRONT ELEVATION 7.0in 4.8in ADA 48" MAX PAGER IS APPROX. 3" ABOVE WHEN BRACKET IS FULL AND TOP PAGER IS ROTATED 90 DEG -� 4.5in 3,8in SIDE ELEVATION NOTES: 1. Single sided kiosk uses 8A (ai 120V. Provide 20A MOCP within CP panel 2. Double sided kiosk uses 9A @120V. Provide 20A MOCP within CP panel 3. Power from above (with standard ceiling height) If ceiling is above 1D'6" contact USRD Project Manager I I I� I, LI Iv I I Y 1' •- I .ADA 4c^ MAX. S O: 'AR-i- ccice RRA'- VAR=' PCP 4'1'iJi.R c1)l:: CCNCu;C: O. MAX • SIDE ELEVATION FRONT ELEVATION t • f 9o'.T coU!iltn--.,_ I'1 • PLAN VIEW 1,441 U,AC..!. i tltC�li' Note: Clear areas cannot overlap RECEIVED CITY OF TUKWILA AUG 0 9 217 PERMIT CENTER • Typical kiosk face quantity (4 faces), final quantity per restaurant to be determined by McDonald's Operations team • 12' clear dimension highly recommended between front counter and kiosk *Existing conditions to be considered • See table locator guideline on page 5 for placement • Wall finish behind kiosk to coordinate with decor • Power from above (with standard ceiling height). If ceiling is greater than 10'6" contact USRD Project Manager, see kiosk cut sheet for additional electrical information • Ideal when placed in front of the service area, less likely to interfere with front counter queuing • Ideal when trying to capture customers from two entrances • Leverages existing decor elements typically seen in our standard decor layouts • This is the preferred placement configuration GENERAL INSTALLATION NOTES: OPTION 1: USE THE BASE PLATE MOUNTING TEMPLATE AS A TEMPLATE TO ALIGN THE PLACEMENT OF THE ANCHOR BOLTS WITH EITHER THE ROTATING OR NON—ROTATING SLOTS. OPTION 2: USING AN ERASABLE MARKER, DRAW AN OUTLINE OF THE ROTATING SLOTS FROM THE BASE STAND COVER ONTO THE FLOOR. PLEASE NOTE: REVIEW ELECTRICAL SECTION (P BEFORE PROCEEDING. ROTATING SLOTS: FOR INSTALLATIONS WHERE T THE KIOSK MAY NEED TO BE ADJUSTED OVER ROTATING SLOTS SHOULD BE USED. NON—ROTATING SLOTS: FOR PERMANENT INSTAL WHERE THE ANGLE OF THE KIOSK WILL NOT NEE ADJUSTED OVER TIME, THE NON—ROTATING SLOT BE USED. E. D FOR ME, C r, DLl/�NCE APPROVED E AI��E 2�F 2017 f sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367.4445 I Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS DESCRIPTION w z SEAL DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR mMcDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another- project is not authorized. ATIO1Sl y of Tukwila BTSnLNG DIVIS1Oi`, PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE USING A DRILL, MAKE FOUR TO SIX HOLES (TOTAL) THAT CORRESPOND TO THE FOUR TO SIX SEPARATE SLOT LOCATIONS. THE DRILLED HOLES NEED TO CONFORM WITH THE CONCRETE ANCHOR BOLT SPECIF ICATIONS. INSTALL ANCHOR BOLTS, PER ANCHOR BOLT SPECIFICATIONS. (SEPARATELY CONTAINED IN PACKAGE NUMBER 1 — SEE PAGE 1) DRILL 3/8" ANCHOR BOLT HOLES HOLES SHOULD BE AT LEAST 4" — 5" DEEP USE "ANCHOR BOLT INSTALLATION" TOOLS AS N ESSA pn KIOSK CUT SHEETS SHEET MANAGEMENT PROJECT NO.: 046-0005, DATE ISSUED: 07/07/17. DRAWN BY: CS REVIEWED BY: NJ NATIONAL STORE # 00472 SHEET NUMBER A1-.3 Architecture 18, 2017 — 3:31 pm csantiago \\smss.sevansolutions.com\DGFileroom\DGDesign\McD Northwest EOTF—MRP\EOTF\046-0005 Tukwila, WA\A1 _Plans.dwg PB = Pullbox VIF = Verify in Field JB = Junction Box ELECTRICAL SCHEDULE EC = Electrical Contractor TAG # QTY DESCRIPTION VOLT/PH' FLA BRK SIZE GOND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS i' 213.00E8 1 TABLE LOCATOR SYSTEM 120/1 ISOLATED 5.2 20A 1/2"C-2#12IG CP:30 SEE RMKS VERIFY FOR GATEWAY/SERVER. TYPICALLY LOCATED IN OFFICE OR IT CLOSET. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS. VERIFY EXACT LOCATION IN FIELD. 213.00E9 1 TABLE LOCATOR SYSTEM 120/1 ISOLATED 2.6 20A 1/2"C-2#12IG CP:30 SEE RMKS VERIFY FOR MONITOR. TYPICALLY LOCATED IN HLS CHASE OR AT PICKUP COUNTER. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS. VERIFY EXACT LOCATION IN FIELD. 800.00E1 2 KIOSK 120/1 ISOLATED SEE RMKS 20A 1 /2"C-2#12IG CP:24,26 JB SEE RMKS SINGLE SIDED KIOSK IS 8 AMPS, DOUBLE SIDED IS 9 AMPS. PROVIDE JB ABOVE CEILING. RUN POWER DOWN KIOSK CHANNEL PER MANUFACTURER INSTRUCTIONS. COORDINATE EXACT LOCATION WITH DECOR DRAWINGS. (1) Flush mount table locator per kiosk face Top of dispenser never higher than 48" AFF TABLE LOCATOR LOCATION A • HME flush mount table locator dispenser • Kiosk parallel to wall • Table locator to be mounted on the wall or partition behind the kiosk • Table locator to always be mounted 4" to the right of the kiosk if space allows • For single -sided kiosk, table locator to always be mounted on the right side * Table locator may be mounted either directly to kiosk or to wall behind kiosk J 3;'i J TABLE LOCATOR LOCATION B • HME flush mount table locator dispenser • Kiosk perpendicular to wall • Table locator to be mounted directly to kiosk, back to back • Table locator should always be mounted on kiosk side closest to the wall • For single -sided kiosk, table locator to always be mounted on the right side --4 ,.--- 1 r • 751 IUIDELII .v. ) SCALE: NOT TO SCALE c5 (213.00 E8 IL IT CLOSET (TY'ICAL) PROJECT PROJECT KIOSK AND TABLE LOCATOR (RADIUS) NEW CONSTRUCTION / MRP CONSTRUCTION DOCUMENT SLIP SHEET DART AL FLOOR SCALE: NOT TO SCALE These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. DLA (TYPICAL) sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 I Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS SEAL DATE: 07/18/2017 EXPIRATION DATE: 08/17/2018 CERTIFICATION PREPARED FOR (jl McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 REVIEWED FOR RECEI SDE COMPLIANCE CITY OFT ,KWILPROVED AUG 0 9'2017 AUG 2 9 2017 PERIV1ii' CCKIOSK & TABLE 'dTEeity of Tukwila LOCATOR DETAILS BUILDING DIVIS101 SHEET TITLE THIS DRAWING IS FOR REFERENCE ONLY THE LAYOUTS SHOWN MAY NOT MATCH SITE SPECIFICS THIS DESIGN CRITERIA SHOULD BE INCORPORATED INTO SITE SPECIFIC DRAWING SETS 4 REVISION MIRO DATE ISSUED BY 2/2/2017 TJG SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 DRAWN BY: CS REVIEWED BY: NJ NATIONAL STORE # 00472 SHEET NUMBER Al .4 Architecture 0 0) 0 uz 0 rn 0 0 r 0 N o CENTER OF ORB/ TOP OF PICKUP HERE SIGN ORDER HERE SIGN ORDER HERE SIGN ' '' PICK-UP SHELF BY G.C. ' " ' " PICK-UP SHELF BY G.C. 1 -2 1 -6 1 -2 1 -6 CONDIMENT CENTER � / (REFERENCE) (TOP DEPTH) SHELF A SE / F TO B MECHANICAL FASTENCONDIMENT CENTER CABINET SEE DECOR DRAWINGS FOR � (REFERENCE) (TOP DEPTH) MECHANICAL FASTEN SHELF TO BASE CABINET SEE DECOR DRAWINGS FOR sevan INTERIOR » 8 CORIANIAL SELECTION INTERIOR .. 8 CORIAN MATERIAL SELECTION MULTI -SITE SOLUTIONS ALIGNED WITH CENTER OF PICK—UP SHELF ALIGNED WITH TOP OF PICK—UP HERE SIGN 4/ CENTERED ON ORDERING AREA HOLD DIMENSION (HOLD) (ABOVE (HOLD) DESIGN LLC. FOR UNDERMOUNTED COUNTER) (ABOVE 2'-6" Regional Office: EQUIPMENT ` - ♦ ^ \ z 4 CO U SER NT ) / TOP DEPTH ) 37704 Hills Tech Drive Farmington Hills, MI 4 331 elephone: 734-367-4445$ -- PICK -IJP HERE ®� > - ORDER FERE „ 1 ' ORDER READY BOARD McCAF6 MENU U MENU 7 1 MENU MENU'- j�f` __� 0 1 �" ` ._ .., ®® W l 1" ADX PLYWOOD T � ' ara n, "'" �S. .:".", ''t "''.rs ",.. � .,. "` .?"z — .. Q z 1" ADX PLYWOOD iar "s := �.':.. ".: .., . �:i `' •— _ :.., .. .::. "dap T` D Z O 1 " ADX PLYWOOD ,.... t ,:.�... _ ��.3t ,.x.. ._a __� _ �_ _ _. '+ :`� —1 — Corporate Office: 4925 Forest Avenue SOLID CORIAN _ 1 1- C9 SOLID CORIAN 1 Q Downers Grove, IL 60515 " QUAL EQUAL / DIGITAL MENU BOARD ARE TO BE RIGHT EDGE JUSTIFIED FOR SUBSTRATE -VERIFY W/COUNTER TOP MANUF. SURFACE AT ALL CUSTOMER -EXPOSED ,� SIDES, COLOR: LINEN' - w 0 m v SUBSTRATE -VERIFY W/COUNTER TOP MANUF. E'- SURFACE AT ALL CUSTOMER -EXPOSED " SIDES. COLOR: LINEN o Q - 0- < W 1- cn Z D SUBSTRATE -VERIFY W/COUNTER TOP MANUF. _ 1/2" SOLID CORIAN SURFACE AT ALL CUSTOMER -EXPOSED SIDES. COLOR: LINEN" nfo@sevansoIutions.com wvnvsevansolutions.com SAFETY - INTEGRITY SUSTAINABILITY (ADA HOLD) "RICE (ADA HOLD) "RICE (ADA HOLD) OR PAPER" - 'c OR PAPER" c u- OR "RICE PAPER" NOTE: COUNTER COORDINATE WITH THE NOTE: COUNTER SUPPORT WALL COORDINATE WITH THE Lt_ NOTE: COUNTER SUPPORT WALL COORDINATE WITH THE REVISIONS SUPPORT WALL 1 a Q P 2 - 4 �' PLACEMENT Q FURNISHED AND o r DECOR DRAWINGS Z 2"DECOR OFFSET (OFFSET ( ^ i FURNISHED AND o '- DRAWINGS �� Z 2„ ( OFFSET ^ = FURNISHED AND '- DECOR DRAWINGS cn 3'-0" �j - w INSTALLED BY G.C. 1 N FRP FINISH ON KITCHEN SIDE �. FROM � w x INSTALLED BY G C 1 N FRP FINISH ON---��� KITCHEN SIDE FROM � w INSTALLED BY G.C. 1 N FRP FINISH ON' KITCHEN SIDE !" Vii, t < z Co U - (MIN.) v V I (3) 2X6 TREATED SILL PLATE - ANCHOR TO FLOOR W 3" SHOT PINS © � 1 FACE OF o COUNTER) � .1 6" TILE BASE Q m w z `-' (3) 2X6 TREATED SILL PLATE - ANCHOR TO FLOOR W 3" SHOT PINS © �� �� FACE OF o COUNTER) -1 6 TILE BASE Q _ i w �' z `-' FLOOR TILE (3) 2X6 TREATED SILL PLATE - ANCHOR TO FLOOR W 3" SHOT PINS © �• "� 6 TILE BASE o lo z d o I io � I = � PICK—UP SHELF 48"O.C. 48 O.C. �I SEE DECOR 48 O.C. a �R ' QUARRY TILE FLOOR SEE DECOR FOR FLOOR TILE QUARRY TILE FLOOR, SEE DECOR FOR FLOOR TILE QUARRY TILE FLOOR SEE DECOR FOR FLOOR TILE NO. I DATE ' DES( FRONT COUNTER PRESENT ORDERING (CUSTOMERS SIDE) PICK-UP SHELF SECTION PICK --UP gm— SHELF SECTION(A.D.A. - ORDER COUNTER SECTIONC N.T.S. SCALE: N.T.S. SCALE: N.T.S. J SCALE: N.T.S. 1 1 1 1 ORB TO BE CENTERED ---,,„6.u. r.li 1 1 i 1 ON PICK—UP SHELF OR PLATFORM — DUAL POINT PICK—UP A � � ` .eit � � `� , B � � \ �`� 1 1 z I i` I ` �, STATION OVERSHELF\t " \R1) 5R2) \R3) FRoNT SEAL spLIT couNTER sup,...sHEET FUTURE READY FOR BAKED GOODS i 1 .."« ,. 14" MIN. L ORB BVERIIEAD& 36 Y2" MIN. (18 STD.) 2'-8" MIN. 2'-8" MIN. 18" 56 Y2" MAX. 3'—O" ADA 3'—O" MIN. (3 —0 STD.) 8'-0' (3 —0 MIN. STD.) / PB = Pullbox JB = Junction Box VIF =Verify in FieldELECTRICAL SCHEDULE EC = Electrical Contractor .. a WASii�i STA + / 3t, / / (SEE CHART (ADA EGRESS BELOW) OVERALL CUSTOMER SERVICE (9, —0» STANDARD) AREA LENGTH VARIES TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS 012.02E1 2 BAKED GOODS DISPLAY CASE 120/1 2.5 15A 1/2"C-2#12 AP -3:1 5-15R 2'-0" - DATE: 07118/2017 EQUIPMENT 2 / (SEE REFERENCE DIMENSIONS) PLAN LAYOUT 211.00E2 2 DELIVERY TABLET 120/1 1.5 20A 1/2"C -2#121G CP:4 SEE RMKS SEE RMKS TABLET LOCATED AT FRONT COUNTER UNTIL FULL POS INTEGRATION. EXPIRATION DATE: 08/17/2018 ISOLATED POWER FROM SAME RECT. AS 219.00E10 VIA TWIST -LOCK ADAPTER PROVIDED WITH UNIT. PROVIDE ADDITIONAL 105262 RECT. WITHIN ASSEMBLY AREA FOR TABLET, 105262 RECEPTACLE TO BE USED CERTIFICATION ONCE FULL POS INTEGRATION IS COMPLETE. COORDINATE EXACT LOCATION IN FIELD. 215.00E1 3 POS REGISTER -FRONT COUNTER 120/1 ISOLATED 3.0 EA. 20A 1/2"C-2#1210 CP:19 104700 2'-0" EC TO RUN 3/4" COND IN WALL FOR FLUSH MTD SPCL. RECEP FOR KEYSTATIONS (MONITOR,CPU & CASH DRAWERS) N.T.S. 215.00E6 2 POS REGISTER - FRONT COUNTER DATA CABLE - - - - 4x4x4 PB 1'-2" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.00E7 FOR POS DATA CABLES 216,04E1 1 ORB MONITOR (MINI)/SCANNER 120/1 ISOLATED 1.5 EA. 20A 1/2"C-2#1210 CP:4 (2) 104700 2'-0" - " " r---., me, * 4 raw ma 1 \ * 4 - - - -, 1, , seISOLATED \ * 4 \ 216.05E1 1 ORB MONITOR 120/1 1.5 EA. 20A 1/2"C -2#121G CP:4 104700 FLUSH ON CLG - 219,00E3 3 POS - RECEIPT PRINTER/CASHLESS 0.7 20A 1/2°C-2#1210 CP:4 104700 2'-O" - 0/ATED PREPARED FOR ELECTRICAL SCHEDULE NOTES: 1. CIRCUIT NUMBERS SHOWN ARE FOR DESIGN INTENT ONLY. ACTUAL CONDITIONS WILL AFFECT CIRCUITRY. 2. WHEN AVAILABLE ONLY ONE BAKED GOODS CASE WILL BE PROVIDED PER RESTAURANT. McDonald's USA LLC These drawings and specifications are the confidential and proprietary 14" NEW ELECTRICAL RECEPTACLES FOR MINI — ORB AND SCANNER - \� ��1� \i X11 FRONT COUNTER - REFERENCE DIMENSIONS property of McDonald's USA, LLC and shall not be copied or reproduced without NEW ELECTRICAL O er war r RECEPTACLE FOR ORB. U I A B C D E F G H I J K written authorization. The contract documents were VERIFY LOCATION IN 13" 12" 18" 18" / 3'-0" 18" / / Overall Customer Service Area in Feet Overall Customer Service Area in inches Pick Up Shelf or Flat Counter Gap to Overshelf Pick -Up Shelf Width Pick -Up ADA Width Pick Up counter Length in Inches Left End of Counter to Register on Center Register to Register on Center Right End of Counter to Register on Center Order Counter Length in Inches prepared re ared for use on this specific site in conjunction with its issue date and are not suitable for use an a different site or ata later time. Use of these drawings for reference or example on another project requires the services of CEILING. PLACE NEAR MONITOR BRACKET. „ EXTEND 2 i�2 N O N N n / EXTEND 2 Y2" CONDUIT UNDER SLAB TO PULL BOX N O N co N U1 / NN, U1 — co U1 N CD NN �, CONDUIT UNDER O 01 O O O -P IN ADJACENT FULL N O O O O o O O O O O O O O O O O >15'-0" „ > 180 Flat Counter N/A N/A 48"48"14"32"18"96"and properly licensed architects engineers. Reproduction of the SLAB TO PULL BOX IN ADJACENT FULL HEIGHT WALL U rTl 0) m HEIGHT WALL U/ OVERALL CUSTOMER SERVICE m AREA r� LENGTH rr� J FT'1 fTl N VARIES � rTl J fTl fTl J >16'-0" >192" Flat Counter N/A N/A 48" 48" 18" 36" 18" 108" contract documents for reuse on another project is ' " " " " " " " 11 not authorized. ELECTRICAL / (SEE REFERENCE DIMENSIONS) 4' ROUGH - IN PLAN >17 -O >204 Flat Counter N/A N/A 60 60 18 36 18 108 — PROJECT LOCATION >18 -0 „ >216 „ Pick Up Shelf N/A N/A 72 „ 72 „ 18 „ 36 „ „ 18 108 „ „m,�.._ REVIEWED FOR >19'-0" >228" Pick Up Shelf 3" 36.5" 44.5" 84" 18" 36" 18" 108" CODE COMPLIANCE APPROVED McDonald's >20'-0" >240" Pick Up Shelf 3" 56.5" 36.5" 96" 18" 36" 18" 108" 2 9 2017 15210 PACIFIC HWY W N.T.S.AUG Standard Pick Up Shelf Lengths are 36.5, 46.5" & 56.5". Using the chart below as a starting point, extra inches should be accounted for by using the following steps: • Increase the Order Counter Length up to 9'-0" Standard. - City of Tukwila BUILDING DIVISION TUKWILA, WA 98188 Location of future Baked Goods Display Case • If increase the Pick Up Shelf size to the next increment. The Pick -Up ADA Width can be decreased to accommodate this change, but must be a minimum of 36" possible, • Increase the ADA Egress Width SHEET TITLE If there is another means of ADA egress near the front counter, the counter cut may be reduced to 28" RECEIVED CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER FRONT COUNTER DETAILS T �R2) �R3 ) THIS DRAWING IS MANAGEMENT i ASHEET F 0 R REFERENCE ONLY PROJECT NO.: 046-0005 DATE ISSUED: 07/07/17 14" MIN. (18" STD.) 2'-8" MIN. 2'-8" MIN. 18" THE LAYOUTS SHOWN MAY NOT MATCH SITE SPECIFICS DRAWN BY: CS THIS DESIGN CRITERIA SHOULD BE INCORPORATED REVIEWED BY: NJ 4....,i / FUTURE (3'-0" STD.)/(3'-0" BAKEDY STD.)/ GOODS DEPLOYMENTr INTO SITE SPECIFIC DRAWING SETS NATIONAL STORE# 00472 PROJECT PROJECT REVISION DATE ISSUED BY SPLIT FRONT COUNTER STANDARD EXISTING SEEQ RETROFIT — 6/19/2017 USRD SHEET NUMBER N.T.S. CONSTRUCTION DOCUMENT SLIP SHEET =u..wa..." Al ini•_. k These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without � written authorization. The contract documents were prepared for use on this specific site conjunction with its issue date and are not suitable for use on a different site or ata later time. Use of these drawings for reference or example on another project requires the services of properly AO" licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. o , . n. 05 Architecture ,t<na"sttts3 'li�BSt i'"+iC§i:"'.' �rfar�a ALL DIFFUSERS, GRILLES, OR REGISTERS TO BE NEW WITH NEW CEILING GRID. VERIFY WITH ARCH FOR EXACT LOCATIONS. MECHANICAL CONTRACTOR TO REPLACE NOTED EXISTING AIR DEVICE. FIELD VERIFY EXACT QUANTITY, LOCATION AND FUNCTIONALITY. GRILLE OR DIFFUSER TO HAVE THE SAME SERVICE, . SAME ITYPE, MODULE SIZE, NECK SIZE, AND CFM BALANCE. NEW GRILLES OR' DIFFUSERS TO BE RELOCATED AS NOTED. RECONNECT TO EXISTING SUPPLY/ RETURN/ EXHAUST DUCT. MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@�sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY- SUSTAINABILITY REVISIONS EXISTING SUPPLY DIFFUSER AND EXHAUST GRILLE SERVING EXISTING PLAYPLACE RESTROOM TO REMAIN EXISTIN SUPPLY DIFFUSERS AND EXHAUST GRILLES SERVING EXISTING RESTROOMS TO REMAIN ro 0 0 N �d- 0 I 0 C: U w w J Lt_ CD 0 0 w 1-- 0 J 0 0 CnU 0 N U 0 z 0 J 0 z 0 / 2 J w w 0 0 z 0 0 0 cri o < -o _ r7 U7 U a z / Qco o U r7 CERTIFICATION EXISTING SUPPLY DIFFUSERS AND RETURN GRILLES SERVING EXISTING KITCHEN TO REMAIN EXISTING EXHAUST GRILLE SERVING EXISTING MOP SINK TO REMAIN PREPARED FOR M.McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for referehce or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION DUCTWORK PLAN 1 /4"=1 '-0" N 10:43am ChristineQuir DRAWING NOTES ALL DUCTWORK SHALL BE RUN BETWEEN OR THROUGH THE JOISTS UNLESS NOTED OTHERWISE. DUCTWORK DESIGNATED WITH (B.J.) SHALL BE RUN BELOW THE JOISTS. DUCT SIZES SHOWN ARE INTERNAL FREE AREA DIMENSIONS UNLESS NOTED OTHERWISE. ALL SHEET METAL DUCTWORK SHALL BE EXTERNALLY INSULATED. INSULATION IS NOT SHOWN FOR CLARITY. SEE MECHANICAL NOTES FOR INSULATION REQUIREMENTS. RETURN AIRFLOW VOLUME SHOWN ON PLAN IS FOR DUCTWORK SIZING PURPOSES WHEN THE UNIT IS IN RECIRCULATION (UNOCCUPIED) MODE. KEYED NOTES NEW SUPPLY DIFFUSER, S-2, REPLACING EXISTING DIFFUSER. NEW DIFFUSER HAS BEEN RELOCATED FOR NEW CEILING AND LIGHTING. PROVIDE EXTENSION AND MODIFICATION TO EXISTING SUPPLY DUCTWORK AS REQUIRED. CONTRACTOR TO FIELD VERIFY EXACT SIZE OF EXISTING NECK. BALANCE TO SPECIFIED CFM, IF SHOWN, McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 NEW RETURN GRILLE, R-1, REPLACING EXISTING GRILLE. NEW RETURN GRILLE HAS BEEN RELOCATED FOR NEW CEILING AND LIGHTING. PROVIDE EXTENSION AND MODIFICATION TO EXISTING RETURN DUCTWORK AS REQUIRED. CONTRACTOR TO FIELD VERIFY EXACT SIZE OF EXISTING NECK. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2011 SHEET TITLE DUCTWORK PLAN DIFFUSERS IN DINING ROOM ARE SPECIFIC TO THE DECOR PLAN SHOWN. DIFFERENT CEILING LAYOUTS MAY REQUIRE A DIFFERENT DIFFUSER TYPES, QUANTITIES, LOCATIONS AND FINISHES/COLORS. REFER TO SHEET M4.0 FOR ABBREVIATIONS, LEGEND, AND ADDITIONAL NOTES. RECEIVED CITY OF TUKWILA AUG 092017 PERMIT CENTER SHEET MANAGEMENT PROJECT NO.: 046-0005 t I j 07/19/2017 DRAWN BY: CQ EXISTING SIDEWALL SUPP Y GRI PLAY •CE LES FIR • REM IN 11411 I O 0111111 0 I I 111 --1 I I I i I 0 --1 i I I I O � I I i I _ _ _ __. T___._........„..._____......„. __ _. 7 � CERTIFICATION EXISTING SUPPLY DIFFUSERS AND RETURN GRILLES SERVING EXISTING KITCHEN TO REMAIN EXISTING EXHAUST GRILLE SERVING EXISTING MOP SINK TO REMAIN PREPARED FOR M.McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for referehce or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION DUCTWORK PLAN 1 /4"=1 '-0" N 10:43am ChristineQuir DRAWING NOTES ALL DUCTWORK SHALL BE RUN BETWEEN OR THROUGH THE JOISTS UNLESS NOTED OTHERWISE. DUCTWORK DESIGNATED WITH (B.J.) SHALL BE RUN BELOW THE JOISTS. DUCT SIZES SHOWN ARE INTERNAL FREE AREA DIMENSIONS UNLESS NOTED OTHERWISE. ALL SHEET METAL DUCTWORK SHALL BE EXTERNALLY INSULATED. INSULATION IS NOT SHOWN FOR CLARITY. SEE MECHANICAL NOTES FOR INSULATION REQUIREMENTS. RETURN AIRFLOW VOLUME SHOWN ON PLAN IS FOR DUCTWORK SIZING PURPOSES WHEN THE UNIT IS IN RECIRCULATION (UNOCCUPIED) MODE. KEYED NOTES NEW SUPPLY DIFFUSER, S-2, REPLACING EXISTING DIFFUSER. NEW DIFFUSER HAS BEEN RELOCATED FOR NEW CEILING AND LIGHTING. PROVIDE EXTENSION AND MODIFICATION TO EXISTING SUPPLY DUCTWORK AS REQUIRED. CONTRACTOR TO FIELD VERIFY EXACT SIZE OF EXISTING NECK. BALANCE TO SPECIFIED CFM, IF SHOWN, McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 NEW RETURN GRILLE, R-1, REPLACING EXISTING GRILLE. NEW RETURN GRILLE HAS BEEN RELOCATED FOR NEW CEILING AND LIGHTING. PROVIDE EXTENSION AND MODIFICATION TO EXISTING RETURN DUCTWORK AS REQUIRED. CONTRACTOR TO FIELD VERIFY EXACT SIZE OF EXISTING NECK. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2011 SHEET TITLE DUCTWORK PLAN DIFFUSERS IN DINING ROOM ARE SPECIFIC TO THE DECOR PLAN SHOWN. DIFFERENT CEILING LAYOUTS MAY REQUIRE A DIFFERENT DIFFUSER TYPES, QUANTITIES, LOCATIONS AND FINISHES/COLORS. REFER TO SHEET M4.0 FOR ABBREVIATIONS, LEGEND, AND ADDITIONAL NOTES. RECEIVED CITY OF TUKWILA AUG 092017 PERMIT CENTER SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/19/2017 DRAWN BY: CQ REVIEWED BY: JT NATIONAL STORE # 11411 SHEET NUMBER SEPARATE PERMIT AND APPROVAL REQUIRED MECHANICAL N O 0 a) :N • L -c 0 v r4.) d- 0 0 00 MECHANICAL NOTES 1 LEGEND ABBREVIATIONS seven MULTI SOLUTIONS TS TEMPERATURE SENSOR ACM AREA CONSTRUCTION MANAGER -SITE DESIGN LLC. Regional 0(fiae: GENERAL: 0 ,AVERAGING TEMPERATURE SENSOR B.J. BELOW JOISTS 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734.367-4445 1. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. I 2. ALL DIMENSIONS, CLEARANCES AND TOLERANCES SHALL BE VERIFIED PRIOR TO INSTALLATION. 3. ALL MATERIALS, FIXTURES AND EQUIPMENT USED SHALL BE IN ACCORDANCE WITH McDONALD'S SPECIFICATIONS. SPECIFICATIONS ARE CONTAINED WITHIN THESE DRAWINGS AND THE McDONALD'S PROJECT MANUAL. ANY CONTRACTOR IN NEED OF A COPY OF THE McDONALD'S PROJECT MANUAL SHALL CONTACT McDONALD'S AREA CONSTRUCTION MANAGER. ANY VARIANCE FROM THE McDONALD'S SPECIFICATIONS SHALL BE REVIEWED AND APPROVED BY THE ENGINEER -OF -RECORD. 4. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND/OR THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. SEE COORDINATION SCHEDULE FOR ADDITIONAL SCOPE OF WORK.v 6. PRIOR TO BUILDING TURNOVER, A COMPLETE START-UP, TEST, ADJUST AND BALANCE SHALL BE PERFORMED ON ALL MECHANICAL SYSTEMS. THIS WORK SHALL BE PERFORMED BY A CERTIFIED TEST AND BALANCE CONTRACTOR. A CERTIFIED TEST AND BALANCE CONTRACTOR CAN BE FOUND BY VISITING:LINE HTTP://WWW.AABCHQ.COM/DIRECTORY HTTP : //WWW. N EB B.O RG/D I R ECTO RY. HTM HTTP://WWW.TABBCERTIFIED.ORG/SITE/CONTENT/CONTRACTORS/SEARCHt 7. UPON COMPLETION OF THE PUNCHLIST, THE MECHANICAL CONTRACTOR AND TEST AND BALANCE CONTRACTOR SHALL SUBMIT REDLINED OR AS -BUILT DRAWINGS ALONG WITH THE TEST AND BALANCE REPORT AND ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS TO THE McDONALD'S AREA CONSTRUCTION MANAGER. A MINIMUM OF TWO (2) COPIES SHALL BE PROVIDED, ONE (1) FOR REGIONAL RECORDS AND ONE (1) FOR THE RESTAURANT. 8. ALL PENETRATIONS OF FIRE -RATED WALLS SHALL BE FIRESTOPPED WITH AN APPROVED AND LISTED FIRESTOPPING SYSTEM. VENTILATION SYSTEMS: 20. ALL ROOFTOP CONDENSING UNITS THAT DISCHARGE HORIZONTALLY SHALL BE ORIENTED SUCH THAT THE' DISCHARGE DOES NOT BLOW IN THE DIRECTION OF AN OUTDOOR AIR INTAKE. 0Corporate CO2 SENSOR FOR ROOFTOP UNIT DEMAND CONTROL VENTILATION BSI BEVERAGE SYSTEM INSTALLER Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutions.com wwwsevansolutions.com HS HUMIDITY SENSOR DCV DEMAND CONTROL VENTILATION SAFETY - INTEGRITY -SUSTAINABILITY V THERMOSTAT REVISIONS E.A.THE A EXHAUST AIR DESCRIPTION p SMOKE DETECTOR EC ELECTRICAL CONTRACTOR <r Ailik EQUIPMENT TAG FAC FIRE ALARM CONTRACTOR FOB FLAT ON BOTTOM R-1 DIFFUSER INFORMATION 1750 CFM LINE 1: TAG, 2: AIRFLOW. FOT FLAT ON TOP 18'10 LINE 3: NECK SIZE FPC FIRE PROTECTION CONTRACTOR SUPPLY AIR DUCT (VERTICAL) GC GENERAL CONTRACTOR DATE "��� I.D. INSIDE DIMENSION 1 1 i y -= ., : _ =±ii =° :.,�`z'=r� RETURN OR EXHAUST AIR DUCT (VERTICAL) KEI KITCHEN EQUIPMENT INSTALLER i �----,��x Y. I I; ED ROUND DUCTVERTICAL DUCT(VERTICAL) z KES KITCHEN EQUIPMENT SUPPLIER SEAL 1. ALL SHEET METAL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH LOCAL CODES AND SMACNA STANDARDS. 2. ALL DUCTWORK DIMENSIONS ARE INTERNAL FREE AREA DIMENSIONS AND SIZED FOR 0.1" W.C. PER 100 FT. OF DUCT. 3. ALL SHEET METAL DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA TABLES FOR 2" W.C. AND SHALL BE SUPPORTED WITH AN APPROVED HANGER AT INTERVALS NOT EXCEEDING 10 FT. 4. ALL DUCT DROPS INTO THE BUILDING SHALL BE INSTALLED WITH FLEXIBLE CONNECTIONS TO ISOLATE THE DUCTWORK SYSTEM FROM NOISE AND VIBRATION. FLEXIBLE CONNECTIONS SHALL BE TESTED IN ACCORDANCE WITH UL 181 AND LISTED AS CLASS 0 OR CLASS 1. 5. ALL DUCT DROPS INTO THE BUILDING SHALL BE OFFSET AS NECESSARY TO ALLOW FOR THE CLEAR INSTALLATION OF THE EXTERNAL DUCTWORK INSULATION. 6. ALL DUCTWORK BRANCHES SHALL BE SUPPLIED WITH A VOLUME DAMPER FOR BALANCING. VOLUME DAMPER SHALL HAVE A 2" OFFSET TO ACCOMMODATELOUVERED EXTERNAL INSULATION.`` 7. TAKE -OFFS FROM RECTANGULAR TO ROUND DUCT SHALL BE DUCTMATE STRAIGHT -SIDED OR CENTER HIGH -EFFICIENCY TAKE -OFFS WITH A 2" DAMPER STAND-OFF TO ACCOMMODATE FOR EXTERNAL INSULATION. 8. ALL DUCTWORK JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS SHALL BE SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), TAPES, ETC. ALL SEALANT MATERIALS SHALL BE LISTED IN ACCORDANCE WITH UL 181A OR 181 B. 9. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED WITHIN THE CEILING SPACE SHALL BE EXTERNALLY INSULATED. INSULATION SHALL BE 2" THICK MICROLITE XG-100 BY JOHNS MANVILLE OR EQUAL. 10. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED OUTSIDE OF THE BUILDING SHALL BE INTERNALLY LINED WITH A 1" THICK FIBERGLASS (MIN. R-4.2) AND EXTERNALLY INSULATED WITH A 1)/2" THICK RIGID POLYSTYRENE, POLYURETHANE OR POLYISOCYANURATE BOARD (MIN. R-7.5). INTERNAL FIBERGLASS INSULATION SHALL BE LINATEX BY JOHNS MANVILLE OR EQUAL. EXTERNAL RIGID BOARD INSULATION SHALL BE THERMAPINK BY OWENSprepared CORNING OR EQUAL. 11. ALL EXPOSED SPIRAL DUCTWORK SHALL BE INTERNALLY INSULATED TO PREVENT CONDENSATION (MIN. R-4.3). INTERNAL INSULATION SHALL BE 1" THICK SPIRACOUSTIC PLUS BY JOHNS MANVILLE OR EQUAL. 12. ALL DUCTWORK PENETRATIONS THROUGH FIRE -RATED WALLS, BARRIERS ORSHEET PARTITIONS SHALL BE PROTECTED WITH A FIRE DAMPER. THE PERIMETER OF THE FIRE DAMPER SHALL BE FIRESTOPPED WITH AN APPROVED AND LISTED FIRESTOPPING MATERIAL. 13. ALL EXTERIOR SHEET METAL DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH AN APPROVED WEATHERPROOFING MATERIAL TO PROTECT AGAINST WATER PENETRATION AND CORROSION. SIDES AND TOP OF EXTERNAL WEATHERPROOFING SHALL BE ALUMAGUARD 60 MIL UV BARRIER BY POLYGUARD OR EQUAL. BOTTOM OF EXTERNAL WEATHERPROOFING SHALL BE VAPORGUARD 5 MIL MEMBRANE BY POLYGUARD OR EQUAL. 14. ALL FLEXIBLE DUCTWORK, METALLIC AND NONMETALLIC, SHALL CONFORM TO THE FOLLOWING: A. 2" THICK INSULATION (R-6.0) B. INTEGRAL VAPOR BARRIER C. LISTED AND LABELED UL 181, CLASS 0 OR CLASS 1 D. INSTALLED IN ACCORDANCE WITH: i. SMACNA STANDARDS, ii. AIR DIFFUSION COUNCIL INSTALLATION GUIDELINES, AND/OR iii. MANUFACTURER'S INSTALLATION INSTRUCTIONS 14. FLEXIBLE DUCTWORK SHALL NOT PENETRATE WALLS. SHEET METAL DUCTWORK IS REQUIRED AT ALL FIRE -RATED AND DRAFTSTOP WALL PENETRATIONS. 15. ALL COVERINGS, LININGS AND ADHESIVES (TAPES, ETC.) SHALL HAVE A FLAME -SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE -DEVELOPED INDEX NOT GREATER THAN 50. 16. DUCT -MOUNTED SMOKE DETECTORS SHALL BE INSTALLED IN SYSTEMS WITH DESIGN CAPACITY GREATER THAN 2,000 CFM. SEE MECHANICAL DRAWINGS FOR LOCATIONS OF SMOKE DETECTORS. DUCT -MOUNTED SMOKE DETECTORS ARE NOT REQUIRED WHEN THE BUILDING IS PROTECTED THROUGHOUT BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM WHERE THE FIRE ALARM SYSTEM IS DESIGNED TO SHUT DOWN THE ROOFTOP UNITS. 17. ALL SUPPLY AIR DIFFUSERS SHALL BE INSULATED TO PREVENT CONDENSATION. 18. ALL AIR DEVICES LOCATED IN DRYWALL CEILINGS SHALL BE SUPPLIED WITH AN INTEGRAL VOLUME DAMPER ACCESSIBLE FROM THE AIR DEVICE FACE TO FACILITATE BALANCING. 19. ALL OUTDOOR AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10 FT. HORIZONTALLY FROM ANY SOURCE OF CONTAMINATION SUCH AS EXHAUST FANS, PLUMBING VENTS, WATER HEATER FLUES, ETC. WHERE A CONTAMINANTSEPARATE SOURCE IS LOCATED WITHIN 10 FT. OF AN INTAKE, THE INTAKE OPENING BE LOCATED A MINIMUM OF 2 FT. BELOW THE CONTAMINANT SOURCE. • M.A. (S) MIXED AIR - SUMMER 4c T�. ilii STEADY-STATE SPEED CONTROLLER �y, 'of M.A. (W) MIXED AIR - WINTER � � sit,. ��` - -- ,��,�� -� PLAQUE DIFFUSER (SHADED AREA DESIGNATES BLANK -OFF PANEL LOCATION) MC MECHANICAL CONTRACTOR � '° 'ip 37190 k7` 1 __, s I A 5' O.A. OUTDOOR AIR nNAL �fPtRES d �/C�1 t ■V°T I I LINEAR SLOT DIFFUSER tri. O.D. OUTSIDE DIMENSION � jrs��} 0/0 OWNER/OPERATOR CERTIFICATION t1I1II1 hIIIlI'd FACE DIFFUSER PC PLUMBING CONTRACTOR R.A. RETURN AIR CEILING -MOUNTED EXHAUST FAN RC REFRIGERATION CONTRACTOR S.A. SUPPLY AIR PREPARED FOR I SPIN -IN COLLAR WITH VOLUME DAMPER MCDOnald's USA S.P. STATIC PRESSURE LLC These drawings and specifications are the I I1 VOLUME DAMPER 11111111111111 FLEXIBLE DUCTWORK TAB TEST AND BALANACE CONTRACTOR propertyentia and proprietary of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were for use on this specific site in conjunction with its issue date and are not suitable for use on a dl ferent site or ata later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PERFORATED FACE DIFFUSER --(Th"" METAL TEE WITH CAP ���, PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 GENERAL (VOTES SHEET MANAGEMENT City Of Tukwila PROJECT NO.: 046-0005 BUILDING DIVISION DATE ISSUED: 07/19/2017 DRAWN BY: CQ REVIEWED BY: JT RECEIVED CITY OF TUKWILA AUG 0 9 2017 NATIONAL STORE # 11411 PERMIT CENTER SHEET NUMBER >Ma a. ��3.i PERMIT ANDSHALL PIS®VAL RE.OU1RED M4 0 MECHANICAL 0 CYT READY HIGHLIGHTED SET\DWG FILES\MECH.DWG 08-04-2015 2014 STANDARD BUILDINGS (MARCH 2015)\- 2 J W 0 0 z r -n 0 0 0 0 0 V) z 0 0 U COORDINATION SCHEDULE GENERAL REQUIREMENTS FURNISH INSTALL FINAL CONNECTION NOTES MECHANICAL PERMIT MC 1-3 HOT WORK; (WELDING) PERMIT (IF APPLICABLE) KES 1-3 REFRIGERATION PERMIT (IF APPLICABLE) MC 1-3 PLUMBING PERMIT PC 1-3 ELECTRICAL PERMIT EC 1-3 FIRE SPRINKLER PERMIT (IF APPLICABLE) FPC 1-3 FIRE ALARM PERMIT (IF APPLICABLE) FAC 1-3 CONTRACTOR COORDINATION REQUIREMENTS HEATING & AIR-CONDITIONING ROOFTOP UNITS, INTAKE AND RELIEF MC MC 1-5, 17, 22 ROOF CURBS MC MC 1-3, 20, 22 GAS PIPING AND GAS PIPE KIT PC PC PC 1-3, 14, 22-23 CONTROLS WIRING MC EC EC 1-3, 19, 22, 24 POWER WIRING EC EC EC 1-3, 19, 22, 24 CONDENSATE TRAP MC PC 1-3, 22-23 CONDENSATE PIPING (IF APPLICABLE) PC. PC 1-3, 22-23 DUCT -MOUNTED SMOKE DETECTOR MC MC EC 1-3, 22, 24 GENERAL EXHAUST SYSTEMS EXHAUST FANS MC MC 1-3, 17, 22 ROOF CURBS MC MC 1-3, 22 CONTROLS (WHERE APPLICABLE) MC EC EC 1-3, 22, 24 POWER WIRING (FAN AND DAMPER) EC EC EC 1-3, 22, 24 TEMPERATURE CONTROLS THERMOSTATS & SUBBASES MC MC EC 1-3, 22, 24 REMOTE SENSORS (RH AND/OR TEMPERATURE) MC MC EC 1-3, 22, 24 CONTROLS WIRING (WHERE APPLICABLE) MC EC EC 1-3, 22, 24 POWER WIRING EC EC EC 1-3, 22, 24 DUCTWORK AND ACCESSORIES GALVANIZED SHEET METAL DUCTWORK MC MC 1-3, 22 EXTERNAL INSULATION MC MC 1-3, 22 INTERNAL INSULATION (IF APPLICABLE) MC MC 1-3, 22 WEATHERPROOFING (IF APPLICABLE) MC MC 1-3, 22 SPIN -IN COLLARS MC MC 1-3, 22 FLEXIBLE DUCTWORK MC MC 1-3, 22 VOLUME/BALANCING DAMPERS MC MC 1-3, 22 FIRE DAMPERS (IF APPLICABLE) MC MC 1-3, 22 FIRESTOPPING (IF APPLICABLE) MC MC 1-3, 22 AIR DEVICES AND ACCESSORIES MC MC MC 1-3, 7, 22, 28 KITCHEN EXHAUST SYSTEMS McDONALD'S BACKSHELF EXHAUST HOODS KES KEI 1-3, 6, 22, 27 CANOPY EXHAUST HOODS (IF APPLICABLE) K ES KEI 1-3, 6, 22, 27 BLACK IRON DUCTWORK KES KEI 1-3, 6, 22 STAINLESS STEEL DUCTWORK (IF APPLICABLE) KES KEI 1-3, 6, 22 ALUMINUM DUCTWORK (IF APPLICABLE) KES KEI 1-3, 6, 22 UL LISTED DUCT WRAP MC MC 1-3, 6, 22 FIRE -RATED DUCT ENCLOSURE (IF APPLICABLE) GC GC 1-3, 6, 20, 22 EXHAUST FANS MC MC 1-3, 6, 17, 22 ROOF CURBS MC MC 1-3, 6, 20, 22 CURB EXTENSIONS MC MC 1-3, 6, 22 CONTROLS (WHERE APPLICABLE) EC EC EC 1-3, 6, 22, 24 POWER WIRING EC EC EC 1-3, 6, 22, 24 FIRE SUPPRESSION SYSTEM KES KES KES 1-3, 16, 22, 27 KITCHEN EQUIPMENT COOLER/FREEZER KES GC 1-3, 27 EVAPORATOR COILS KES MC 1-3, 27 CONDENSATE PIPING PC PC PC 1-3, 23, 27 REMOTE CONDENSING UNIT (MAC) KES MC 1-3, 22, 27 ROOF CURBS MC MC 1-3, 22 REFRIGERANT PIPING KES POWER WIRING EC MC EC MC EC 1-3, 22, 27 1-3, 22, 24, 27 CONTROL WIRING EC EC EC 1-3, 24, 27 PIPE PORTALS MC MC 1-3, 22 ICE MACHINES KES KEI 1-3, 27 WATER SUPPLY PIPING KES KEI BSI 1-3, 27 REMOTE CONDENSING UNITS KES MC 1-3, 22, 27 ROOF CURBS MC MC 1-3, 22, 27 REFRIGERANT PIPING KES MC MC 1-3, 22, 27 POWER WIRING EC EC EC 1-3, 22, 24, 27 CONTROL WIRING KES EC EC 1-3, 24, 27 PIPE PORTALS MC MC 1-3, 22 KES KES 1-3, 27 GAS PIPING (IF APPLICABLE) POWER WIRING PC PC PC 1-3, 23, 27 EC EC EC 1-3, 24, 27 CONTROL CABLE (6' CLAMSHELL ONLY) MC EC EC 1-3, 23, 24, 27 FRYERS K ES KES 1-3, 27 GAS PIPING (IF APPLICABLE) GRIMEWER WIRING PC PC PC 1-3, 23, 27 EC EC EC 1-3, 24, 27 MISCELLANEOUS ITEMS 10:43am ChristineQuiroz 0 N aj T H:\17334\dwg\MECH.dwg FIRE SPINKLER SYSTEMS FPC FPC FPC 1-3, 15, 25 HVAC EQUIPMENT START-UP TAB 1-3, 22 TEST, ADJUST AND BALANCE HVAC SYSTEMS TAB 1-3, 22 DOOR GRILLES (IF APPLICABLE) MC GC 1-3, 20, 22 ROOF/WALL OPENINGS GC 1-3, 20-24 APPLIANCE BACKFLOW PREVENTION KES/BSI PC PC 1-3, 23, 27 CO2 DETECTION SYSTEM MC EC EC 1-3, 22, 27 NOTES: 1. THIS SCHEDULE IS INTENDED AS A GUIDE FOR THE WORK TO BE PERFORMED. ALL WORK SHALL BE COORDINATED BETWEEN THE McDONALD'S AREA CONSTRUCTION MANAGER AND ALL GC AND 0/0 SUBCONTRACTORS. 2. : ONE (1) COPY OF THE DECOR PACKAGE DRAWINGS SHALL BE SUPPLIED TO THE GENERAL CONTRACTOR AND EACH OF THE SUBCONTRACTORS. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTORS TO INSURE THAT THEY HAVE RECEIVED THE DECOR PACKAGE DRAWINGS. 3. FOR ANY WORK NOT CLARIFIED IN THIS SCHEDULE OR IN THE NOTES AND SPECIFICATIONS, PLEASE CONSULT THE McDONALD'S AREA CONSTRUCTION MANAGER FOR SCOPE OF WORK. 4. ALL ROOFTOP UNIT EQUIPMENT SUPPLIED BY THE MECHANICAL CONTRACTOR AND THE KITCHEN EQUIPMENT SUPPLIER SHALL BE ON SITE AT THE SAME TIME FOR A SINGLE CRANE LIFT. EQUIPMENT SITE ARRIVAL DATE SHALL BE COORDINATED BETWEEN THE AREA CONSTRUCTION MANAGER, MECHANICAL CONTRACTOR AND KITCHEN EQUIPMENT SUPPLIER. 5. ALL ROOFTOP UNITS INSTALLED IN McDONALD'S RESTAURANTS SHALL BE HIGH EFFICIENCY EQUIPMENT. THE INSTALLATION OF STANDARD EFFICIENCY ROOFTOP UNITS IS PROHIBITED. 6. ALL KITCHEN EQUIPMENT REQUIRING EXHAUST SHALL BE INSTALLED IN ACCORDANCE WITH THESE PLANS. ANY VARIATION FROM THESE PLANS SHALL BE REPORTED TO THE AREA CONSTRUCTION MANAGER AND THE ENGINEER -OF -RECORD. 7. WHERE GYPSUM BOARD CEILINGS ARE INSTALLED, THE MECHANICAL CONTRACTOR SHALL SUPPLY DRYWALL MOUNTING FRAMES FOR LAY -IN TYPE DIFFUSERS. 8. ALL WORK SHOWN ON P1.6 DRAWING(S) SHALL BE COMPLETED BY THE BEVERAGE SYSTEM INSTALLER (OR K.E.S.) UNLESS OTHERWISE NOTED IN THE PLUMBING DRAWINGS. 9. ALL WORK ON P1.0 & P1.2 DRAWING(S) SHALL BE BY THE PLUMBING CONTRACTOR. 10. THE BEVERAGE SYSTEM INSTALLER FURNISHES, RUNS AND CONNECTS ALL FLEXIBLE WATER AND SYRUP LINES FOR ALL AFFECTED EQUIPMENT INCLUDING THE FOLLOWING: A. HOT CHOCOLATE B. COFFEE BREWER C. ICE MACHINE D. O.J. E. SODA TOWERS 11. ALL WATER HEATERS INSTALLED IN McDONALD'S RESTAURANTS SHALL BE HIGH EFFICIENCY SEALED -COMBUSTION WATER HEATERS. THE INSTALLATION OF STANDARD EFFICIENCY GRAVITY -VENTED WATER HEATERS IS PROHIBITED. 12. THE AREA CONSTRUCTION MANAGER, PLUMBING CONTRACTOR AND KITCHEN EQUIPMENT SUPPLIER SHALL COORDINATE WHICH 3 -COMPARTMENT SINK IS BEING INSTALLED IN THE RESTAURANT. NOTE: THE INSTALLATION OF A POWERSOAK SINK REQUIRES A LARGER WATER HEATER THAN THE STANDARD 3 -COMPARTMENT SINK. 13. ALL GAS PIPING FOR COOKING EQUIPMENT SHALL TERMINATE IN THE CEILING PRIOR TO THE INSTALLATION OF THE PIPING CHASE. UPON INSTALLATION OF THE CHASE, THE GAS PIPING SHALL THEN BE CONTINUED IN THE CHASE FOR FINAL CONNECTION TO THE APPLIANCE. 14. ALL GAS PIPING FOR ROOFTOP EQUIPMENT SHALL BE BROUGHT UP THROUGH THE BASE OF THE UNIT TO MINIMIZE ROOF PENETRATIONS. WHERE THIS IS NOT POSSIBLE, THE PLUMBING CONTRACTOR SHALL PROVIDE THE NECESSARY PIPE PORTALS ON ROOF. 15. ALL FIRE PROTECTION DRAWINGS CONTAINED WITHIN THIS SET ARE STRICTLY FOR REFERENCE ONLY. FIRE SPRINKLER DRAWINGS SHALL BE DESIGNED AND PERMITTED BY A FIRE PROTECTION CONTRACTOR. 16. ALL R-102 WET CHEMICAL FIRE SUPPRESSION SYSTEMS FOR TYPE I HOODS SHALL BE DESIGNED AND INSTALLED BY A LOCAL ANSUL AGENT. THE USE OF DRY CHEMICAL SYSTEMS IS PROHIBITED. THE LOCAL ANSUL AGENT CONTRACT IS HANDLED THROUGH THE KITCHEN EQUIPMENT SUPPLIER. 17. ALL ROOFTOP UNITS AND EXHAUST FANS ARE SUPPLIED WITH A FACTORY -INSTALLED DISCONNECT SWITCH. 18. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECT SWITCHES FOR REMOTE CONDENSING UNITS. 19. ALL ELECTRICAL CONDUITS FOR ROOFTOP EQUIPMENT SHALL BE BROUGHT UP THROUGH THE BASE OF THE UNIT TO MINIMIZE ROOF PENETRATIONS. WHERE THIS IS NOT POSSIBLE, THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE NECESSARY PIPE PORTALS ON ROOF. 20. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 21. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 22. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 23. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 24. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 25. SEE FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION. 26. SEE FIRE ALARM DRAWINGS FOR ADDITIONAL INFORMATION. 27. SEE KITCHEN DRAWINGS FOR ADDITIONAL INFORMATION. 28. SEE DECOR DRAWINGS FOR ADDITIONAL INFORMATION. AIR DEVICE SCHEDULE TAG MANUFACTURER MODEL BORDER SIZE COLOR ACCESSORIES NOTES S-2 TITUS OSPDI LAY -IN 24x24 VARIES 4,6,7 1,7 PRICE R-1 TITUS 23RL LAY -IN 24x24 VARIES 3,7 1,7 PRICE 60L ACCESSORIES: GRID DUCTWORK - NOTES: FOR NECK SIZES 46"x22"x27"H PLENUM WITH 141'0 SIDE INLET (SEE DETAIL M3.0) FIBERGLASS INSULATION FOR DIFFUSER BACKPAN CONTRACTOR SHALL PROVIDE ADDITIONAL 4 FT. T -BAR FOR FRAMING SHALL BE INSTALLED BY DOOR MANUFACTURER. GRILLE LOCATED 12" FROM BOTTOM OF DOOR FINISH WILL VARY: STORAGE, RESTROOMS - WHITE ROOM, VESTIBULES - WHITE, BLACK OR PAINTABLE/PRIME FINAI COI OR WITH DFCOR PI ANS). 1. COMBINATION DAMPER AND EQUAUZING 2. PLASTER FRAME FOR DRYWALL CEILING INSTALLAT1ON 3. SQUARE -TO -ROUND COLLAR CONNECTION 4. BACKPAN INSULATION 5. OPPOSED BLADE DAMPER 6. BLANK -OFF PANEL AS SHOWN ON PLAN 7. PLASTER FRAME MAY BE NECESSARY COORDINATE WITH DECOR DRAWINGS 8. 1" FUER MEDIA 9. 120V POWER MODULE 10. WALL -MOUNTED LED DISPLAY THERMOSTAT 1. SEE PLAN 2. FABRICATE 10 ON DRAWING 3. PROVIDE 1" 4. NOT USED 5. GENERAL DIFFUSER 6. DOOR GRILLE SHALL BE 7. AIR DEVICE * KITCHEN, * DINING COAT (COORDINATF REVIEWED FOR CODE COMPLIANCE APPROVED AUG 292017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2017 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS 0 z SEAL CERTIFICATION PREPARED FOR ftkRicDonald's USA LLC These drawings and specifications are the confidential andproprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE SCHEDULE SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/19/2017 DRAWN BY: CQ REVIEWED BY: JT NATIONAL STORE # 11411 1 SHEET NUMBER M 4. 1 MECHANICAL ROOF EXISTING METER CABINET T EXISTING 1200 AMPERE SERVICE TO REMAIN 120/208V., 3PH., 4W. J r J. r Lighting • Panel 1 "LP -1" In ILJ J Appliance Panel 3 "AP -3" 1 n l.J 1 J r 1 I I I 1 I I I I I I I I I I I I I I I I I I I I L J Appliance Panel 1 n I,J "AP -1" r Appliance Panel 2 I "AP -2" n 1 I.1 L r r Main Distribution Panel 1 I "MDP" ®2 ---- • T- m - L_ _1_ _ I• 1L co 1 1 .! 1 m 1 In J m m I L-- - -+- - - - a 1 m I m I 4 ao I no I m I I DO m I I I I L J -1 L E1.0 ELECTRICAL ONE LINE DIAGRAM - NO SCALE ONEUNE NOTES; OL1. CONTRACTOR MAY REUSE EXISTING CIRCUIT BREAKERS FOR NEW WORK IF FEASIBLE, OTHERWISE PROVIDE NEW. NEW CIRCUIT BREAKERS SHALL BE OF TYPE AND MANUFACTURER TO MATCH EXISTING. OL2. ELECTRICAL CONTRACTOR SHALL CLEAN AND RETORQUE EXISTING PANEL BOARDS AND ALL BRANCH BREAKERS. EXERCISE EXISTING BREAKERS AND REPLACE ALL DEFECTIVE PARTS. OL3. ALL WORK SHALL COMPLY WITH THE 2014 EDITION OF NATIONAL ELECTRICAL CODE AND ALL THE CITY OF TUKWILLA AMENDMENTS. COORDINATE EXACT CODE REQUIREMENTS AND LOCAL AMENDMENTS WITH LOCAL INSPECTOR PRIOR TO ANY INSTALLATION. OL4. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN DIRECTORIES FOR ALL PANEL BOARDS. TRACE EXISTING CIRCUITS AND IDENTIFY ALL LOADS. EXISTING CONDITIONS: THESE DRAWINGS ARE BASED ON INFORMATION PROVIDED TO OUR OFFICE AT THE TIME OF DESIGN AND A PROTOTYPICAL MCDONALDS DESIGN. THEREFORE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO, SERVICE LOCATION, SERVICE LAYOUTS, SECONDARY FEEDER LENGTH, SECONDARY FEEDER SIZE, TELEPHONE SERVICE LOCATION, ETC..AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO BID. FAILURE TO DO" SO MAY CONSTITUTE THAT THE CONTRACTOR PROVIDE ANY AND ALL ADDITIONAL EQUIPMENT, LABOR, - ETC... TO MEET THE INTENDED DESIGN PARAMETERS. 0:52am cad03 F:\E1.0-SYM_TUKWILLA,WA. DWG SF: 1.00 CC JN: H:\17021.43 FN: E1.0-SYM_TUKWILLA,WA ONE UNE DIAGRAM LEGEND: DENOTES EXISTING WORK TO REMAIN DENOTES NEW WORK NEW LOAD: RECEPTACLE: UGHTING: 8.6 4.6 KW 0 100% KW 0 125% = 8.6 KW = 5.8 KW TOTAL = 14.4 KW 40.0 A EXISTING SERVICE IS RATED 1200 A 0 120/208 V. 3PH 4W. CONTRACTOR SHALL CONFIRM WITH THE UTILITY COMPANY THAT THE EXISTING SERVICE MAXIMUM LOAD IS LESS THAN OR EQUAL TO 928 A OR 333.8 KW. (333.8 KW X 2.78 X 125 % PER NEC 220-87 (2))=1160 A PROVIDE WRITTEN DOCUMENTATION TO ARCHITECT/OWNER THAT THE ELECTRICAL SERVICE IS IN COMPLIANCE. EXISTING SERVICE INFORMATION HAS BEEN TAKEN FROM PICTURES FROM A CURSORY SITE SURVEY. CONTRACTOR SHALL VERIFY EXACT SERVICE CHARACTERISTICS AND FIELD CONDITIONS ON SITE PRIOR TO BID AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. GENERAL NOTES: 1. THE BUILDING WHERE THE WORK IS TO BE PERFORMED IS OCCUPIED. SCHEDULE ANY DISCONNECTIONS AND RECONNECTION WITH THE MCDONALDS REPRESENTATIVE. ONE WEEK NOTICE IS REQUIRED. ARRANGE WORK SO AS NOT TO INTERRUPT ANY ELECTRICAL POWER. TELEPHONE, FIRE, COMMUNICATIONS AND OTHER SYSTEMS DURING NORMAL BUILDING HOURS. - ) ; WHERE CORE DRIWNG AND CUTTING OF FLOORS OR WALLS IS REQUIRED, CONTRACTOR SHALL USE METAL DETECTORS OR OTHER APPROVED DEVICES TO DETERMINE AND AVOID INTERFERENCE WITH EXISTING CONCEALED FEEDERS AND PIPES. RECEIVE APPROVAL FROM BUILDING OWNER AND STRUCTURAL ENGINEER PRIOR TO START OF ANY DRIWNG. USE TEMPORARY CABLES AND ELECTRICAL APPARATUS AS REQUIRED. THE CONTRACTOR SHALL USE GREAT DIUGENCE AND CARE IN DISCONNECTING VARIOUS SYSTEMS. RECONNECT SYSTEMS THAT SERVE ADJACENT AREAS IF SUCH SYSTEMS HAVE BEEN DISRUPTED DURING DEMOUTION WORK. 2. ALL CONCEALED CONDUIT THAT IS ABANDONED SHALL HAVE ALL WIRING REMOVED FROM THE SOURCE, AND STUBS SHALL BE CUT FLUSH WITH FLOOR OR CEIUNG SLABS OR WALLS AND SURFACE PATCHED TO MATCH EXISTING. ALL EXPOSED CONDUIT, INCLUDING ABOVE DROPPED CEIUNG, THAT IS NO LONGER IN USE SHALL BE REMOVED UNLESS OTHERWISE NOTED. 3. MAKE THOROUGH INSPECTION OF EXISTING PANELS THAT REMAIN AND ARE AFFECTED BY NEW WORK. CLEAN AND TIGHTEN ALL CABLE, BUS AND BREAKER DEVICE CONNECTIONS. REPORT ANY ABNORMAL CONDI11ONS. PROVIDE ADDITIONAL BREAKERS AS REQUIRED TO EXISTING PANEL SPACE TO REPLACE DEFECTIVE DEVICES AND AS REQUIRED FOR NEW WORK. 4. THE EXISTING PANELBOARDS SHALL BE MODIFIED AS REQUIRED AND NEW OVERCURRENT DEVICES AND CONNECTIONS ADDED. CONSULT THE PANEL MANUFACTURER AND FOLLOW THEIR RECOMMENDATIONS. ALL EXISTING BRANCH CIRCUITS WHICH ARE REUSED SHALL BE PROVIDED WITH NEW CIRCUIT BREAKERS. SHORT CIRCUIT INTERRUPTING CAPACITY OF NEW OVERCURRENT DEVICES SHALL MATCH OR EXCEED EXISTING. 5. ALL ELECTRICAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE MCDONALDS STANDARD PROJECT SPECIFICATIONS AND ALL OTHER DRAWINGS RELATED TO THE PERFORMANCE OF THE WORK. 6. EQUIPMENT LABELS AND INSTRUCTIONS REGARDING THE APPUCATION AND INSTALLATION OF THE USTED EQUIPMENT SHALL BE FOLLOWED TO INSURE THAT THE EQUIPMENT IS BEING INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S USTING INSTRUCTIONS. THE TEMPERATURE RATING OF THE EQUIPMENT TERMINATION MUST BE CORRELATED WITH THE CONDUCTOR AMPACITY TO PREVENT OVERHEATING AND PREMATURE FAILURE. 7. COORDINATE WORK WITH FIELD CONDITIONS AND OTHER TRADES AND INSTALL CONDUIT AND BOXES TO CLEAR EMBEDDED DUCTS, OPENINGS AND OTHER STRUCTURAL FEATURES. 8. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF ALL APPUCABLE CODES AND REGULATIONS. 9. ALL LIGHTING FIXTURES ARE TO BE LOCATED AS REQUIRED ON THE JOB TO CLEAR DUCTS, PIPING, EQUIPMENT, AND/OR MECHANICAL UNITS. 10. ALL OF THE BOXES. CONDUITS, WIRES, CONTROL STATIONS, SLEEVES, INSERTS. FRAMES AND ANCHORS ARE NOT SHOWN ON THE DRAWINGS. ONLY MAJOR ITEMS ARE SHOWN. COORDINATE ALL WORK AS REQUIRED FOR PROPER DEMOUTION AND INSTALLATION. 11. NO WIRING SHALL BE DONE PRIOR TO THE CONTRACTOR'S REVIEW OF THE PROJECT EQUIPMENT SHOP DRAWINGS. COORDINATE FIELD CONDITIONS WITH THE DESIGN DOCUMENTS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION FOR FINAL RESOLUTION. WORK THAT HAS TO BE REPLACED DUE TO LACK OF PROPER SHOP DRAWINGS COORDINATION SHALL BE DONE AT CONTRACTOR'S EXPENSE. 12. ALL OUTLETS BOXES SHALL BE PROVIDED WITH PROPER COVER PLATES. 13. IN AREAS WHERE COUNTERS ARE PROVIDED. COORDINATE EXACT LOCATION OF OUTLETS AND WIRING WITH MILLWORK. 14. ALL CODE VIOLATIONS ENCOUNTERED RELATING TO EXISTING SYSTEM WIRING WHICH IS OR MAY BE AFFECTED BY THE WORK TO BE INSTALLED SHALL BE IDENTIFIED AS TO TYPE OF VIOLATION, LOCATION, DESCRIPTION AND CODE -REFERENCED SECTION AS PART OF THIS CONTRACT. THIS DATA SHALL BE IN TYPEWRITTEN FORM, WITH DRAWINGS IF REQUIRED FOR LOCATION AND SHALL BE GIVEN TO THE ARCHITECT, OWNER'S REPRESENTATIVE AND ENGINEER. ' 15. EXISTING SERVICES SHOULD NOT BE INTERRUPTED WITHOUT THE CONSENT OF THE OWNER'S REPRESENTATIVE AND SHOULD BE DONE ONLY FOR THE DATE AND DURATION MUTUALLY AGREED UPON. 16. CIRCUITS ARE SIZED ASSUMING NO MORE THAN THREE CURRENT CARRYING CONDUCTORS IN A SINGLE CONDUIT. FOR CONDUITS CONTAINING MORE THAN THREE, PROVIDE APPROPRIATE DERATING OF CONDUCTORS PER PRESENT APPUCABLE CODES. 17. SEAL ALL WALL AND FLOOR CONDUIT PENETRATIONS. 18. CONTRACTOR SHALL REPAIR EXISTING DEFECTIVE BRANCH CONDUCTORS. WHEN THE EXISTING CONDUCTORS ARE FOUND TO BE DEFECTIVE WHEN RECONNECTING THEM TO THE NEW ELECTRICAL EQUIPMENT, REPLACE THE DEFECTIVE LENGTH OF CONDUCTORS. PROVIDE A SPUCE BOX IN THE HORIZONTAL RUN OF EACH EXISTING FEEDER AFFECTED BY THE NEW WORK. THE SPUCE BOX SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE LOCATION OF THE LOAD SERVED. 19. TESTING - AFTER WIRES ARE IN PLACE AND CONNECTED TO DEVICES AND EQUIPMENT, THE SYSTEM SHALL BE TESTED FOR SHORTS AND GROUNDS. ALL HOT WIRES, IF SHORTED OR GROUNDED, SHALL BE REMOVED AND REPLACED. LC1. COIL VOLTAGES FOR ALL CONTACTORS SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. LC2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL WIRING, CONNECTIONS, TERMINATIONS, ETC. THAT ARE NOT PROVIDED BY THE EMS SUPPLIER FOR A COMPLETE, FULLY OPERATIONAL AND CODE COMPLIANT LIGHTING CONTROL SYSTEM. LC3. ALL COMPONENTS FOR THIS LIGHTING CONTROL SYSTEM SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. SEE BOXED NOTE BELOW FOR OPTIONS. LC4. ALL COMPONENTS SHALL BE UL LISTED AND LABELED AND THE SYSTEM SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL ENERGY CODE REQUIREMENTS. LC5. ALL CONTACTORS SHALL BE LOCATED IN A NEMA 1 ENCLOSURE WITH SCREW TYPE COVER MOUNTED DIRECTLY ABOVE UGHTING PANEL OR SWITCHGEAR SO AS TO BE ACCESSIBLE. LC6. ALL CONTACTORS SHALL BE RATED FOR 30 AMP LOADS UNLESS NOTED OTHERWISE AND SHALL BE HID RATED WHERE REQUIRED. DEMOLITION NOTES: D1. THE FOLLOWING PROVIDES A GENERAL SCOPE OF WORK FOR THE ELECTRICAL CONTRACTOR FOR THE DEMOLITION REQUIREMENTS OF THIS SITE. THIS SECTION IS NOT ALL INCLUSIVE, AND THE CONTRACTOR SHALL VISIT THE SITE AND COMPARE EXISTING CONDITIONS TO THE, REQUIREMENTS DENOTED ON TIME CONSTRUCTION DOCUMENTS TO DETERMINE THE EXACT :EXTENT OF THE DEMOLITION WORK REQUIRED. E.C. SHALL PROVIDE ALL DEMOLITION WORK REQUIRED IN ORDER TO ALLOW FOR THE COMPLETE INSTALLATION AS DENOTED WITHIN THESE DRAWINGS. D2. PLAN THE SEQUENCE AND PHASING OF DEMOLITION AND CONSTRUCTION SO THAT THE ENTIRE PROJECT IS CARRIED OUT WITH MINIMUM POWER SYSTEM INTERRUPTION. AT LEAST ONE WEEK PRIOR TO DEMOLITION, SUBMIT A PLAN FOR REVIEW. THE DEMOLITION WORK SHALL NOT START WITHOUT THE BUILDING ENGINEER'S AND CONSTRUCTION MANAGER'S APPROVAL. D3. UMITS OF DEMOUTION AREA SHALL BE AS INDICATED ON ARCHITECTURAL, MECHANICAL PLUMBING, AND ELECTRICAL DRAWINGS. CAREFULLY REVIEW THE ARCHITECTURAL, MECHANICAL. AND PLUMBING DRAWINGS FOR ADDITIONAL ITEMS TO BE REMOVED AND/OR RELOCATED. INCLUDE ALL COSTS IN BASE BID FOR REMOVAL, DISCONNECTING, OR RELOCATION OF EQUIPMENT AFFECTED BY DEMOLITION OF OTHER TRADES. D4. EXISTING ELECTRICAL EQUIPMENT NOT SHOWN ON THIS DRAWING; HOWEVER, REQUIRED TO BE REMOVED AND/OR RELOCATED BY DEMOLITION, SHALL BE INCLUDED IN SCOPE OF WORK. D5. COORDINATE WITH OWNER'S REPRESENTATIVE, AT TIME OF BIDDING, THE LOCATION FOR STORING SALVAGEABLE EQUIPMENT. D6. ELECTRICALLY DISCONNECT ALL ELECTRICAL EQUIPMENT BEING REMOVED BY DEMOLITION BACK AT PANELBOARD. AFTER 1LSIING TO DETERMINE "POWER -OFF' TO EQUIPMENT. REMOVE AND DISPOSE OF EQUIPMENT. UNLESS SPECIFICALLY NOTED OTHERWISE. D7. ALL CONDUIT AND WIRE REMOVED SHALL BE REMOVED COMPLETELY BACK TO SOURCE, AND WHERE REQUIRED BRANCH OVER -CURRENT PROTECTION DEVICES PROPERLY LABELED "SPARE". D8. ALL CONDUIT AND WIRE FOR EQUIPMENT LOCATED OUTSIDE AREA OF DEMOLITION SHALL REMAIN IN SERVICE. THE EXACT METHOD OF RE-ROUT1NG NEW CONDUIT AND WIRE TO EQUIPMENT REMAINING SHALL BE COORDINATED WITH WORK OF OTHER TRADES, PRIOR TO ANY INSTALLATION. D9. ALL EXISTING CONDUIT AND WIRE INTERFERING WITH THE NEW WORK SHALL BE RE-ROUTED CONCEALED IN THE NEW CONSTRUCTION, UNLESS NOTED OTHERWISE. D10. REMOVE EXISTING CEIUNG TILES AND LIGHTS, WHERE SO REQUIRED, TO PROPERLY INSTALL NEW ELECTRICAL WORK IN CONCEALED CEIUNG SPACES. REINSTALL TILES AND LIGHTS TO MATCH EXISTING FINISHES UPON COMPLETION OF THE WORK. D11. ALL EXISTING FIRE ALARM EQUIPMENT IS TO REMAIN. ALL CDUNG MOUNTED FIRE ALARM DEVICES SHALL BE DISCONNECTED AND RELOCATED TO THE SAME LOCATION IN THE NEW CEIUNG. PROVIDE NEW CONDUIT AND WIRE (TO MATCH EXISTING). TO MAINTAIN CONTINUITY OF SERVICE FOR EQUIPMENT WHICH SHALL REMAIN BOTH INSIDE AND OUTSIDE THE AREA OF DEMOLITION. D12. COORDINATE ALL RECEPTACLE, TELEPHONES, DATA OUTLETS & ASSOCIATED CONDUIT & WIRING TO BE DISCONNECTED AND REMOVED WITH ARCHITECT AND CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF BID. D13. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SALVAGE REQUIREMENTS FOR ALL EQUIPMENT REMOVED AS PART OF THE DEMOLITION WORK WITH THE CONSTRUCTION PROJECT MANAGER. ALL EQUIPMENT TO BE SALVAGED AND/OR REUSED SHALL BE PROTECTED FROM DAMAGE UNTIL REINSTALLED OR THE TIME PERIOD WHEN IT IS TURNED OVER TO THE OWNER AND/OR THE PROJECT MANAGER. D14. CONTRACTOR SHALL VISIT SITE, AND DOCUMENT EXISTING CIRCUITS SERVING UGHTING FIXTURES. RECEPTACLES, PLUG-IN STRIPS. MOTORS. AND SPECIAL POWER EQUIPMENT WITHIN UMITS OF DEMOUTION. PRIOR TO SUBMITTING A PROPOSAL EXAMINATION OF EXISTING °CONDITIONS: VISIT THE SITE AND CAREFULLY EXAMINE THE BUILDING ELECTRICAL SYSTEMS SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THE WORK, BEFORE SUBMITTING PROPOSALS. SUBMISSION OF A PROPOSAL WILL BE EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE RECOGNIZED. DRAWING Deye CV WA SYMBOL DWG. NO. DESCRIPTION E1.0 SYMBOL UST, ONE LINE AND NOTES E1.1 FLOOR PLAN - POWER E2.0 FLOOR PLAN - UGHTING E3.0 GENERAL ELECTRICAL NOTES E4.0 ENERGY CODE SYMBOLS AND ABBREVIATIONS Deye CV WA SYMBOL DESCRIPTI❑N O SYMBOL DESCRIPTION rat) SINGLE POLE SWITCH, 3W=THREE WAY SWITCH, K=KEYED SWITCHED ® BUZZER EXPIRES 0 . 05 20 T TRANSFORMER SIGN ® BUTTON FOR BUZZER OATF FXPIRA110N nATF O JB WITH DUPLEX CONVENIENCE OUTLET (FLUSH WITH CEILING) 10 01 PULLBOX JB WITH SINGLE CONVENIENCE OUTLET PANELBOARD 01 JB WITH DUPLEX CONVENIENCE OUTLET o CIRCUIT BREAKER ei JB WITH TWO DUPLEX CONVENIENCE OUTLETS A AMPERES O JB WITH FLUSH FLOOR MOUNTED OUTLET ACM AREA CONSTRUCTION MANAGER CD JB WITH SPECIAL PURPOSE OUTLET AFF ABOVE FINISHED FLOOR ® JB WITH ISOLATED GROUND OUTLET ® ®=IG4700A, ® ® =IG5262 C CONDUIT ® = IG4710, ® =IG5261, CCT CIRCUIT I< INTERCOM STATION W/ 3/4'C- TO MAIN STATION EC ELECTRICAL CONTRACTOR K TELEPHONE JACK GC GENERAL CONTRACTOR Q JUNCTION BOX - WALL OR CEILING MOUNTED GFI/GFCI GROUND FAULT CIR d I ❑P DISCONNECT SWITCH RLNNE.iE1N GND GROUND CODE COMPI IA% Q STUB UP THRU ROOF IG ISOLATED GROUND APPROVED O THERMOSTAT SENSOR W/ 1/2'C- UP TO CEILING SPACE JB JUNCTION BOX ��JJ 9 2011 © MOTOR CONNECTION KES KITCHEN EQUIPMENT SUPPLIER CONDUIT RUN CONCEALED IN CEILING OR WALLS MLD MAIN LUGS ONLY . / \ / CONDUIT RUN IN FLOOR SLAB ukwil WP WEATHERPROOF City of DIVI MANUAL SWITCH (T=THERMAL OVERLOADS) RECEIVEBUILDINGIILDIBUILDINGDill. 111X HOT (SHORT), NEUTRAL (LONG), EQUIP & 'X' DENOTES ISOLATED GRD GRD (LONG WITH DOT), & CITY OF TUKWILA - J -BOX WITH FINAL EQUIPMENT CONNECTION : A QzrthJ la rs 0 RA'I E pEpma t Emig AND * NOTE: NOT ALL SYMBOLS IN SYMBOL UST ARE USED. REQUIRED sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-3674445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@sevansolutions.com www.sevansolutions.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS DESCRIPTION w ci z SEAL Deye CV WA 0 tP . •(' v7M O A z SR 146,4", FCISTBV- QVAL Gti NATIONAL STORE # EXPIRES 0 . 05 20 8 SIGN 07/18/2017 05/05/2018 OATF FXPIRA110N nATF CERTIFICATION PREPARED FOR ('j McDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different elle or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE SYMBOL LIST, ONE LINE AND NOTES 3 I SHEET MANAGEMENT c OJECT NO.: 046-0005 D E ISSUED: 07/19/2017 D WN BY: SR R IEWED BY: DD NATIONAL STORE # 11411 SHEET NUMBER E 1 • 0 Electrical 10:52am cad03 N 0 —PWR_TU KWILLA,WA.DWG MDP AP -1 LP -1 AP -2 AP -3 ( • /\ (213.001 E8,12 OEP C-� OEP 2Q(213.001 E9) (215.001 E8) 15.00IE10) 900. N 900.51: -E1; m (215.001 E9) EXISTING MODULAR SWITCHBOARD WITH PANEL MDP, AP -1, AP -2, AP -3 & LP -1 DENOTES EXISTING AREA NOT IN CONTRACT UNLESS SPECIFICALLY NOTED 1 FLOOR PLAN - POWER 1- L L Li 1 El y SCALE: 3/16"=1'-0" 0' 4' 8' 12' 16' 20' 24' POWER PLAN NOTES; 'o6 o L} PROVIDE POWER WITHING CEILING FOR CONNECTION TO SELF ORDER KIOSKS. COORDINATE EXACT LOCATION OF KIOSKS WITH DECOR DRAWINGS. PROVIDE 2#12, 1#12 GRD., & 1#12 ISOLATED GROUND ON A 20A DEDICATED CIRCUIT FED FROM THE EP PANEL FOR EVERY ONE (1) DOUBLE SIDED OR TWO (2) SINGLE SIDED KIOSKS. IF RESTAURANT DOES NOT RECEIVE KIOSK, PROVIDE J -BOX AND 1/2" CONDUIT WITH PULL STRINGS TO TWO (2) SPARE 20A/1P BREAKERS WITHIN CP PANEL. VERIFY IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2#12, 1#12 GRD TO AVAILABLE 20A/1P BREAKER. CONNECT CIRCUIT TO THREE (3) 5-20R RECEPTACLES, ONE (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND VALENCE AT 7'-9 A.F.F.). ONE (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY LOCATED IN MANAGER'S OFFICE), AND ONE (1) RECEPTACLE FOR MONITOR (TYPICALLY LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. -c; 1 GENERAL NOTES; 1. FIELD VERIFY EXACT LOCATION OF ALL PANELBOARDS. 2. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AND ALL LOCAL AMENDMENTS. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT CIRCUIT NUMBERS AND WIRING ROUTING IN FIELD. 4. REFER TO ARCHITECTURAL DRAWINGS FOR SCOPE OF DEMOLITION WORK. 5. ALL GENERAL RECEPTACLES IN PUBLIC AREAS SHALL BE TAMPER RESISTANT, UNLESS NOTED OTHERWISE. ELECTRICAL SCHEDULE NOTES; ES1. REFER TO ARCHITECTURAL DRAWINGS & KiTCHEN EQUIPMENT DRAWINGS FOR EXACT NUMBER AND LOCATIONS OF KITCHEN EQUIPMENT. ES2. ALL 15 AMP & 20 AMP SINGLE PHASE RECEPTACLES LOCATED WITH -IN KITCHEN AREA SHALL HAVE GFI PROTECTION. ES3. CONTRACTOR SHALL COORDINATE EXACT WIRING REQUIREMENTS (IE. PHASE REQUIREMENTS) FOR ISOLATED GROUND EQUIPMENT, POS EQUIPMENT AND AUTOMATIC BEVERAGE SYSTEM WITH EQUIPMENT VENDOR PRIOR TO INSTALLATION. ES4. CONTRACTOR SHALL VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS WITH McDONALDS OPERATION MANAGER, PRIOR TO INSTALLATION. ES5. LOADING, WIRING, CIRCUIT BREAKER AND PLUG TYPES ARE PROVIDED BY MCDONALDS FROM EQUIPMENT MANUFACTURER'S CUT SHEETS. KITCHEN EQUIPMENT IS ASSUMED TO BE NON -CONTINUOUS OPERATION ELECTRICAL EQUIPMENT. ES6. CONNECT NEW EQUIPMENT TO THE EXISTING SPARE CIRCUIT(S) IN EXISTING PANELS OR CIRCUITS MADE SPARE DURING DEMOLITION. PANEL AND CIRCUIT NUMBERS ARE SHOWN ONLY AS A GUiDE, ELECTRICAL CONTRACTOR SHALL VERIFY EXACT CIRCUITS TO BE UTILIZED IN FIELD. ES7. VERIFY EXACT ELECTRICAL REQUIREMENTS OF NEW EQUIPMENT PRIOR TO ANY INSTALLATION. NOTIFY PROJECT MANAGER OF ANY DISCREPANCIES. ES8. CONNECT RELOCATED EQUIPMENT TO THE EXISTING CIRCUIT(S) WHICH IT WAS PREVIOUSLY POW FROM BEFORE RENOVATION. ELECTRICAL CONTRACTOR .MAY REUSE EXISTING BRANCH CiRCUIT AN WIRING, IF FEASIBLE, AND EXTEND EXISTING CONDUIT AND WIRING OF TYPE TO MATCH EXISTING LOCATION. VERIFY EXACT PANEL & CIRCUIT(S) TO BE UTILIZED IN FIELD. RECEIVE CITY OF TUK alt i 1 vl i'1 I sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutlons.com www.sevansolutions.com SAFETY -INTEGRITY - SUSTAINABILITY REVISIONS. SEAL PI mo Raw `�"" ""'InMil ELECTRICAL SCHEDULE EC a Metrical Contractor TAG # QTY DESCRIPTION VOLT/PHASE AMPS HP RECEPT TYPE BRKR SIZE COND / WIRE PNL/CCT HGT AFF SPECIAL REMARKS 213.00E8 1 RADIUS TABLE LOCATOR SYSTEM 120/1 ISOLATED 5.2 - SEE RMKS 20A 1/2'C-2#12IG AP -2: 4, SEE NOTE # ES6 VERIFY FOR GATEWAY/SERVER. TYPICALLY LOCATED IN OFFICE OR IT CLOSET. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS, VERIFY EXACT LOCATION IN FIELD. 213.00E9 1 RADIUS TABLE LOCATOR SYSTEM 120/1 ISOLATED 2.6 - SEE RMKS 20A 1/21C -2#121G AP -2: 4, SEE NOTE #ES6 VERIFY FOR DIMNITER. TYPICALLY LOCATED WIN HLS CHASE OR RAPICKUP COUNTER. ORDINATE EXACT REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS, VERIFY EXACT LOCATION IN FIELD. 215.00E8 1 POS REGISTER - FRONT COUNTER DATA CABLE - - 4x4x4 PB - -_ 1'-2" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.00E9 FOR POS DATA CABLES 215.00E9 1 POS REGISTER - FRONT COUNTER DATA CABLE - - 4x4x4 PB - - - 1'-2" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.00E8 AND 2 1/2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 215.00E10 1 POS REGISTER - FRONT COUNTER DATA CABLE - - 4x4x4 PB - - - 1'-2" EXTEND 2 1/2" CONDUIT TO 215.00E11 FOR POS DATA CABLES 215.00E11 1 POS REGISTER - FRONT COUNTER DATA CABLE - - 4x4x4 PB - - - 1'-2" EXTEND 2 1!2" CONDUIT TO ABOVE CEILING AND TO 215.00E10 FOR POS DATA CABLES 216.04 El 1 ORB MONITOR (MINI) 120/1 ISOLATED 1.5 EA. - IG4700 20A 1/2"C -2#121G AP -1: 5, SEE NOTE # ES6 1'-6" - 120/1 ISOLATED 1.5 EA. - IG4700 20A 1/2"C-2#12IG AP -1.5, SEE NOTE # ES6 0 CLG 216.05 El 1 ORB MONITOR 120/1 ISOLATED SEE RMKS - JB EA. 20A EA. 1/2"C -2#121G' EA. AP -1:6,8, SEE NOTE # ES6 SEE RMKS SINGLE SIDED KIOSK IS 8 AMPS, DOUBLE SiDED IS 9 AMPS. PROVIDE JB ABOVE CEILING. RUN POWER DOWN KIOSK CHANNEL PER MANUFACTURER INSTRUCTIONS. COORDINATE EXACT LOCATION WITH DECOR DRAWINGS. 800.00 El 2 KIOSK 120/1 ISOLATED VERIFY VERIFY VERIFY 20A 1/2"C-2#12IG SEE NOTE # ES8 - - 900.51 El 3 RELOCATED POS PC HARDWARE - FRONT COUNTER GENERAL NOTES; 1. FIELD VERIFY EXACT LOCATION OF ALL PANELBOARDS. 2. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AND ALL LOCAL AMENDMENTS. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT CIRCUIT NUMBERS AND WIRING ROUTING IN FIELD. 4. REFER TO ARCHITECTURAL DRAWINGS FOR SCOPE OF DEMOLITION WORK. 5. ALL GENERAL RECEPTACLES IN PUBLIC AREAS SHALL BE TAMPER RESISTANT, UNLESS NOTED OTHERWISE. ELECTRICAL SCHEDULE NOTES; ES1. REFER TO ARCHITECTURAL DRAWINGS & KiTCHEN EQUIPMENT DRAWINGS FOR EXACT NUMBER AND LOCATIONS OF KITCHEN EQUIPMENT. ES2. ALL 15 AMP & 20 AMP SINGLE PHASE RECEPTACLES LOCATED WITH -IN KITCHEN AREA SHALL HAVE GFI PROTECTION. ES3. CONTRACTOR SHALL COORDINATE EXACT WIRING REQUIREMENTS (IE. PHASE REQUIREMENTS) FOR ISOLATED GROUND EQUIPMENT, POS EQUIPMENT AND AUTOMATIC BEVERAGE SYSTEM WITH EQUIPMENT VENDOR PRIOR TO INSTALLATION. ES4. CONTRACTOR SHALL VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS WITH McDONALDS OPERATION MANAGER, PRIOR TO INSTALLATION. ES5. LOADING, WIRING, CIRCUIT BREAKER AND PLUG TYPES ARE PROVIDED BY MCDONALDS FROM EQUIPMENT MANUFACTURER'S CUT SHEETS. KITCHEN EQUIPMENT IS ASSUMED TO BE NON -CONTINUOUS OPERATION ELECTRICAL EQUIPMENT. ES6. CONNECT NEW EQUIPMENT TO THE EXISTING SPARE CIRCUIT(S) IN EXISTING PANELS OR CIRCUITS MADE SPARE DURING DEMOLITION. PANEL AND CIRCUIT NUMBERS ARE SHOWN ONLY AS A GUiDE, ELECTRICAL CONTRACTOR SHALL VERIFY EXACT CIRCUITS TO BE UTILIZED IN FIELD. ES7. VERIFY EXACT ELECTRICAL REQUIREMENTS OF NEW EQUIPMENT PRIOR TO ANY INSTALLATION. NOTIFY PROJECT MANAGER OF ANY DISCREPANCIES. ES8. CONNECT RELOCATED EQUIPMENT TO THE EXISTING CIRCUIT(S) WHICH IT WAS PREVIOUSLY POW FROM BEFORE RENOVATION. ELECTRICAL CONTRACTOR .MAY REUSE EXISTING BRANCH CiRCUIT AN WIRING, IF FEASIBLE, AND EXTEND EXISTING CONDUIT AND WIRING OF TYPE TO MATCH EXISTING LOCATION. VERIFY EXACT PANEL & CIRCUIT(S) TO BE UTILIZED IN FIELD. RECEIVE CITY OF TUK alt i 1 vl i'1 I sevan MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutlons.com www.sevansolutions.com SAFETY -INTEGRITY - SUSTAINABILITY REVISIONS. SEAL DIC T4s oV w A Sqr �',�, .C' e A 0 z 17 CISTP, R�� IjJc.q I: SR sS1atvAL 5 NATIONAL STORE # 11411 EXPIRES 0 ' 05Aga 8 SIGN 07/18/2017 05/05/2018 DATF FXPIRAIION DATF CERTIFICATION PREPARED FOR QMcDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of property licensed architects and engineers. Reproduction of the contract documents for reuse . on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 REVIEWEC T9dCOMP APPROk iLA AUG 2 9 rR City of Tu BUILDING C SPECIAL NOTES; Si. CONTRACTOR TO VISIT THE SITE AND CAREFULLY EXAMINE THE BUILDING ELECTRICAL SYSTEMS SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICUL11ES THAT WILL ATTEND THE EXECUTION OF THE WORK, BEFORE SUBMITTING PROPOSALS. SUBMISSION OF A PROPOSAL WILL BE EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE RECOGNIZED. S2. PHASING OF THIS WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AT TIME OF BIDDING. INCLUDE ALL COSTS IN BASE BiD PROPOSAL TO IN WORK AS SCHEDULED BY GE ARATE CONTRACTOR. y„ y d ` , 1/�+�f'Ep�-Afl gain T (A�ff�� "„ `•3����;e�=fi; !��a� �;."�"I'n44 ,' '��`'�i: +1 , [ 4.' i1V,l 1 1�� SF: 1.00 CC JN: H:\17021.43 FN: E1 .1 -PWR_TUKWILLA,WA APPROVAL !"PED SHEET TITLE FLOOR PLAN - OWER FOR ,MANCE o17 SHE MANAGEMENT PROJECT O.: 046-0005 DATE ISS ED: 07/19/2017 IjJc.q I: SR 2 1 BY: DD NATIONAL STORE # 11411 SHEET NUMBER El .1 Electrical M -a 0 0 E 0 ro 0 N 0 N co F:\E ORDER ALL UGHT FIXTURES FROM: SECURITY UGHTING SYSTEMS, INC. PHONE: (800) 544-4848 FAX: (847) 279-0642 PRIMARY DAYLIGHT ZONE (346 SQ.FT) PHOTOCELL SENSOR SWITCH # CM -PC -ADC APPROVED EQUAL. REFER TO PHOTOCELL CONTROL DETAIL ON THIS SHEET. (TYPICAL) POWER PACK SENSOR SWITCH # PP -20 OR APPROVED EQUAL. (TYPICAL) IF 12 F12S 27a 0 F12S 27b 0 F12S 27b SE DA 2 F12S 27a F12S 27b Li o F12S F12S F12S F12S AP— LP -1 AP -2 AP -3 172 SQ. SEE NOTES EL4 & EL5 (TYPICAL) KEY DENOTES FIXTURE TYPE DENOTES CIRCUIT NUMBER F12 F12 41 LIGHTING FIXTURES SHOWN HALF SHADED SHALL BE WIRED TO THE NIGHT LIGHTING CIRCUIT AND PROVIDED WITH A BATTERY TYPE EMERGENCY BALLAST. SEE NOTE EL3 AND EL5 ON THIS SHEET. LIGHTING E . I XT U R E SCHEDULE- -27c_' F12A 0 X k) 4) 31 :. LAMPS MOUNTING 1 MANUFACTURER AND CATALOG NUMBER GA12 F12A 27c Iv O 6" LED DOWN LIGHT W/ WHITE TRIM 12.5W LED RECESSED DINING SECURITY LIGHTING # SL6LED1K-35K-9—WH/DBXQL i\ t 31 12W 2 RECESSED DINING SECURITY UGHTING # LB6LEDA10L35K9WW SA/DBXQL F12S ® .� 12W o27c' RECESSED DINING SECURITY LIGHTING # LB6LEDA10L35K9WW/SA/DBXQL F20 EXIT SIGN WITH BATTERY BACKUP 1.8W 31 SURFACE - SECURITY LIGHTING: PRB. SEE NOTE LS1 & LS2 ON THIS SHEET. P1 0 PENDANT LIGHT BEAN PENDANT (1)-8W LED PENDANT DINING EXACT FIXTURE TYPE TO BE COORDINATED WITH DECOR FIRM & AREA CONSTRUCTION MANAGER P2 T� PENDANT LIGHT LED STIX PENDANT___X F1 O 27r LED PENDANT DINING �ONDARY (LIGHT ZONE (~ Fi 31 j 0- 0 SQ.FT) 1j I ® 41 2 / 31 1--- U. L 0 270 270 F12 27 0 f,{12 -_ d7b 'O'-- /X0 F12A -27a 412 F20 41 — 172 SQ. SEE NOTES EL4 & EL5 (TYPICAL) KEY DENOTES FIXTURE TYPE DENOTES CIRCUIT NUMBER F12 F12 41 LIGHTING FIXTURES SHOWN HALF SHADED SHALL BE WIRED TO THE NIGHT LIGHTING CIRCUIT AND PROVIDED WITH A BATTERY TYPE EMERGENCY BALLAST. SEE NOTE EL3 AND EL5 ON THIS SHEET. LIGHTING E . I XT U R E SCHEDULE- S f W A s �� A. GI trl VERIFY FINAL LIGHTING LAYOUT AND LIGHTING FIXTURE SPECIFICATION W/ ACM AND SEATING & DECOR COMPANY PRIOR TO ORDERING LIGHTING PACKAGE. EXPIRES 0 • 05 20' MARK SYMBOL DESCRIPTION LAMPS MOUNTING LOCATION MANUFACTURER AND CATALOG NUMBER WATTS TYPE F12 O 6" LED DOWN LIGHT W/ WHITE TRIM 12.5W LED RECESSED DINING SECURITY LIGHTING # SL6LED1K-35K-9—WH/DBXQL F12A t 6" LED WALL WASH 12W LED RECESSED DINING SECURITY UGHTING # LB6LEDA10L35K9WW SA/DBXQL F12S ® 6" LED DOWN LIGHT W/ SILVER TRIM 12W LED RECESSED DINING SECURITY LIGHTING # LB6LEDA10L35K9WW/SA/DBXQL F20 EXIT SIGN WITH BATTERY BACKUP 1.8W LED SURFACE - SECURITY LIGHTING: PRB. SEE NOTE LS1 & LS2 ON THIS SHEET. P1 0 PENDANT LIGHT BEAN PENDANT (1)-8W LED PENDANT DINING EXACT FIXTURE TYPE TO BE COORDINATED WITH DECOR FIRM & AREA CONSTRUCTION MANAGER P2 PENDANT LIGHT LED STIX PENDANT___X (3)-32W LED PENDANT DINING EXACT FIXTURE TYPE TO BE COORDINATED WITH DECOR FIRM & AREA CONSTRUCTION MANAGER FLOOR PLAN — LIGHTING SCALE: 3/16"=1'-0" 0' 4' 8' 12' 16' 20' 24' LIGHTING PLAN GENERAL NOTES: LG1. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE POINT-TO-POINT WIRING FOR ALL UGHTING FIXTURES. ALL WIRING SHALL 3E #12 AWG MINIMUM AND SHALL BE DERATED PER THE REQUIREMENTS OF NEC 310-15 WHERE REQUIRED. E.C. SHALL BE RESPONSIBLE FOR SUBMITTALS OF POINT—TO—POINT WIRING DIAGRAMS WHERE REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. LG2. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT CIRCUIT NUMBERS AND WIRING ROUTING IN FIELD. CIRCUIT NUMBERS HAVE BEEN TAKEN FROM PROTOTYPICAL DRAWINGS AND ARE TO BE UTILIZED AS A GUIDE ONLY. VERIFY EXACT CIRCUIT NUMBERS TO BE UTIUZED IN FIELD. CONNECT NEW UGHTING TO EXISTING BRANCH CIRCUITS MADE SPARE BY DEMOLITION OF EXISTING LIGHTING. LG3. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AND ALL LOCAL AMENDMENTS. COORDINATE EXACT CODE REQUIREMENTS AND LOCAL AMENDMENTS WITH LOCAL INSPECTOR PRIOR TO ANY INSTALLATION. LG4. REFER TO ARCHITECTURAL DRAWINGS FOR SCOPE OF DEMOLITION WORK. LG5. ALL SOFFIT LOCATIONS, UGHTING, & SUPPLY GRILLS SHALL BE COORDINATED WITH DECOR COMPANY DRAWING PRIOR TO INSTALLATION. LG6. EC SHALL VERIFY THAT NOT MORE THAN 3% VOLTAGE DROP EXISTS FROM THE UGHTING PANEL TO ANY UGHTING FIXTURE OR SIGNAGE BALLAST. LIGHTING SCHEDULE NOTES LS1. UGHT FIXTURE PERFORMANCE SPECIFICATION: EC SHALL SELECT UGHT FIXTURES FROM SECURITY LIGHTING THAT MEET OR EXCEED THE FOLLOWING REQUIREMENTS: A. B. C. D. SHEET METAL SHALL BE MINIMUM 22 GAGE STEEL. WHITE ENAMEL PAINTED. PLASTIC LENSES SHALL BE PRISMATIC ACRYLIC. Al2 PATTERN, UNLESS NOTED OTHERWISE. LAY—IN FIXTURES SHALL HAVE HINGED. GASKETED DROP DOWN DOOR FRAMES. PROVIDE FLANGE KITS FOR INSTALLATION IN GYPSUM BOARD CEIUNG. VERIFY IN THE FIELD. LS2. ALL INTERIOR UGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. LS3. ALL UGHT FIXTURES SHALL BE LABELED BY MANUFACTURER TO MAXIMUM WATTAGE USTED IN UGHTING FIXTURE SCHEDULE. MANUFACTURER SHALL PROVIDE REDUCE WATTAGE LABEL FOR LIGHT FIXTURE AS REQUIRED TO COMPLY WITH ENERGY CODE REQUIREMENTS. LS4. UGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL OF ILLUMINATION. LAMP AND BALLAST SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS SHALL BE APPROVED IN WRITING BY McDONALD'S CORPORATION. LS5. ORDER LED EXIT SIGNS WITH LEITER COLORS THAT COMPLY WITH LOCAL CODES. — FOR RED LETTERS USE #PRB (UNIVERSAL), — FOR GREEN LEITERS USE #PGB (UNIVERSAL), OR IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE & DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. DENOTES EXISTING AREA NOT IN CONTRACT UNLESS SPECIFICALLY NOTED LIGHTING PLAN KEY NOTES: n VERIFY SWITCHBANK LOCATION IN FIELD PRIOR TO INSTALLATION. ALL UGHTING SHALL BE LOCALLY SWITCHED UNLESS SPECIFICALLY NOTED OTHERWISE IN ACCORDANCE WITH 2015 WASHINGTON STATE ENERGY CONSERVATION CODE, SWITCHES THAT ARE NOT LOCATED WITHIN THE AREA BEING SERVED SHALL IDENTIFY THE LIGHTING SERVED AND INDICATE THEIR STATUS. ALL SOFFIT LOCATIONS, UGHTING, & SUPPLY GRILLS SHALL BE COORDINATED WITH DECOR COMPANY DRAWING PRIOR TO INSTALLATION. ECONNECT UGHTING TO EXISTING BRANCH CIRCUITS SERVING THE AREA MADE SPARE BY DEMOLITION. CIRCUIT NUMBERS ARE SHOWN AS A GUIDE ONLY. VERIFY EXACT PANEL & CIRCUIT NUMBERS TO BE UTIUZED IN THE FIELD. WIRE NEW INTERIOR UGHTING THROUGH EXISTING UGHTING CONTROL SYSTEM. SPECIAL NOTES: S1. CONTRACTOR TO VISIT THE SITE AND CAREFULLY EXAMINE THE BUILDING ELECTRICAL SYSTEMS SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THE WORK, BEFORE SUBMITTING PROPOSALS. SUBMISSION OF A PROPOSAL WILL BE EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE RECOGNIZED. S2. PHASING OF THIS WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AT TIME OF BIDDING. INCLUDE ALL COSTS IN BASE BID PROPOSAL TO INSTALL WORK AS SCHEDULED BY THE GENERAL CONTRACTOR. CM -PC -ADC PRIMARY DAYUGHT ZONE (495 SQ.FT) RIK - 120 V ORN - 277 V 2 NO SCALE PHOTOCELL CONTROL DETAIL EMERGENCY LIGHTING NOTES ELI. EL2. CONNECT EMERGENCY BATTERY FIXTURE TO NORMAL UGHTING CIRCUIT AHEAD OF LOCAL SWITCHING. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 City of Tukwila BUILDING DIVISION ' ADJACENT AREA, EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY UGHTING AT ALL EGRESS EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS. INSTALL WP J—BOX WITHIN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY EXTERIOR EMERGENCY EGRESS UGHTING (TYPICAL). EL3. EMERGENCY BATTERY UGHTING SHALL BE LOCATED AND AIMED IN FIELD TO PROVIDE FOR MAXIMUM ILLUMINATION OF AREA. E.C. SHALL VERIFY EXACT PLACEMENT IN THE FIELD WITH McDONALD'S PROJECT MANAGER. EL4. IF NOT INSTALLED BY MANUFACTURER, EC SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF THE EMERGENCY INVERTER BALLAST FOR NIGHT LIGHTING FIXTURES SHOWN ON THIS SHEET. EL5. EL6. EL7. ALL LED FIXTURES DENOTED AS NIGHT UGHTING SHALL BE PROVIDED WITH DUAL LITE UGHTING INVERTER MODEL # LG1—T. INVERTER SHALL BE CAPABLE OF ILLUMINATING FIXTURE 100% FOR 1.5 HOURS TO COMPLY WITH NEC SECTION 700 AND UL924. E.C. SHALL NOT INSTALL MORE THEN FOUR FIXTURES TO EACH INVERTER. PROVIDE ADDITIONAL INVERTERS AS NECESSARY. CONNECT NEW EXIT AND EMERGENCY/NIGHT UGHTING TO EXISTING EXIT AND EMERGENCY/NIGHT BRANCH CIRCUITS SERVING THE AREA WITH SPARE CAPACITY MADE BY EXISTING UGHTING WITHIN THE ROOM BEING REMOVED. VERIFY EXACT PANEL & CIRCUIT NUMBER TO UTIUZED IN FIELD. PROVIDE LOCK—OUT CUP ON CIRCUIT BREAKER (IF ONE DOES NOT CURRENTLY EXIST) [NEC 700.12)F]. EMERGENCY UGHTING HAS BEEN DESIGNED PER NFPA 101 TO MAINTAIN 1 FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO UGHTING DESIGN, EMERGENCY UGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. SF: 1.00 CC JN: H:\17021.43 FN: E2.0-LTG._TUKWILLA,WA RECEIVED Y OF SEPAItiu'E US ERMIT AND APPROVAL. 1'11 d y t`J TIED MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@sevansolutIons.com www.sevanselutIons.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS SEAL DIck S f W A s �� A. GI trl A z s`rlOVAL G EXPIRES 0 • 05 20' SR IGN 07/18/2017 05/05/2018 DATF FXPIRATION DATF CERTIFICATION PREPARED FOR RMcDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with ite issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE FLOOR PLAN - LIGHTING SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/19/2017 DRAWN BY: SR REVIEWED BY: DD NATIONAL STORE # 11411 SHEET NUMBER 2.0 Electrical r•r) 0 -0 0 0 0 N 0 GENERAL ELECTRICAL NOTES: INSTALLATION METHODS: M1. ALL ELECTRICAL MATERIAL USED ON THIS PROJECT SHALL BE "UL" USTED AND LABELED. M2. ALL DIMENSIONS SHOWN ARE TAKEN FROM FACE OF WALL FINISH. THE EC SHALL MAKE NECESSARY DIMENSIONAL ALLOWANCES. ALL DIMENSIONS SHOWN ARE TO CENTER UNE OF OUTLET BOX AND/OR RECEPTACLE UNLESS NOTED OTHERWISE. M3. ALL J -BOXES, DCO'S, AND OTHER ELECTRICAL DEVICES SHOWN SHALL BE RECESSED MOUNTED INTO A WALL, FLOOR OR CEIUNG UNLESS SPECIFICALLY NOTED OTHERWISE. M4. ALL RECEPTACLES (EXCEPT SPECIFIED HUBBELL PIN & SLEEVE TYPES) SHALL BE FURNISHED BY THE EC. THE RECEPTACLES INCLUDING PIN AND SLEEVE TYPE SHALL BE INSTALLED BY THE EC. M5. EC SHALL PROVIDE AND INSTALL STAINLESS STEEL COVER PLATES ON ALL RECEPTACLES AND J -BOXES. ADDITIONALLY, EC SHALL PROVIDE AND INSTALL ORANGE NYLON COVER PLATES MARKED "COMPUTER ONLY" ON ALL ISOLATED GROUND/DEDICATED CIRCUIT RECEPTACLES. PURCHASE PJ8C0 (ONE DUPLEX) OR PJ82C0 (TWO DUPLEX) FROM HUBBELL M6. ALL ELECTRICAL CONDUCTORS SHALL BE CONNECTED TO RECEPTACLES USING ONLY THE TERMINAL SCREWS. RECEPTACLE BACK WIRE/QUICK CONNECTIONS SHALL NOT BE USED. M7. EC SHALL COORDINATE WITH KITCHEN EQUIPMENT SUPPUER, MECHANICAL CONTRACTOR AND GC FOR FINAL LOCATIONS AND CONNECTION REQUIREMENTS OF ALL EQUIPMENT PRIOR TO INSTALLATION OF ANY CONDUIT AND/OR STUB -UP LOCATIONS. M8. FOR GRILLS, FRYERS AND ANSUL SYSTEMS, EC SHALL EXTEND CONDUIT AND CONDUCTORS DOWN CHASE OR WALL TO TERMINAL BLOCK MOUNTED ON EQUIPMENT AND MAKE FINAL CONNECTIONS TO TERMINAL BLOCKS. M9. ALL HOLES IN THE FRONT COUNTER FOR THE POS CORDS AND CABLES SHALL BE LOCATED BY OWNER AND DRILLED BY GC. GROUNDING: G1. ALL BRANCH AND FEEDER CIRCUITS SHALL BE GROUNDED BY TWO METHODS. THE FIRST METHOD SHALL INCLUDE AN INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR CONTAINED WITHIN THE SAME CONDUIT AS THE PHASE CIRCUIT CONDUCTORS AND SIZED PER NEC SECTION 250 REQUIREMENTS. THIS INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL HAVE ONE END PROPERLY TERMINATED AT THE EQUIPMENT GROUND BUS IN THE CORRESPONDING CIRCUIT BREAKER PANEL AND THE OTHER END TERMINATED AT THE GROUNDING CONTACT OF A GROUNDING RECEPTACLE AND TO THE JUNCTION BOX OR TO AN EQUIPMENT CABINET, AS APPUCABLE. THE SECOND METHOD PROVIDES EQUIPMENT GROUNDING VIA METAWC CONDUIT THAT IS CONNECTED AND TERMINATED IN FITTINGS USTED FOR GROUNDING PER NEC SECTION 250 REQUIREMENTS. BOTH GROUNDING METHODS ARE REQUIRED IN A MCDONALD'S RESTAURANT ISOLATED GROUND SHALL BE INSTALLED WHERE INDICATED ON PLAN AND AS SHOWN IN POS ISOLATED GROUND/DEDICATED CIRCUIT DETAIL ON SHEET E4.2. G2. THE BUILDING GROUNDING SYSTEM IS EXISTING TO REMAIN. CONDUIT AND WIRE: w1. THE FOLLOWING WIRING METHODS SHALL NOT BE USED: NON-METAWC SHEATHED CABLE (ROMEX, NM, NMC, & NMS), ARMORED CABLE TYPE AC (BX), ELECTRICAL NON-METAWC TUBING, TYPE ENT (SMURF-TUBE). W2. CONDUIT RUNS MAY BE COMBINED EXCEPT WHERE ISOLATED GROUNDS ARE USED. IG CIRCUITS SHALL BE RUN IN SEPARATE CONDUITS. ALL HOME RUNS SHALL SIZED BASED ON DERATED CONDUCTOR AMPACITIES AND INCREASE CONDUIT AND WIRE SIZE AS REQUIRED BY NEC SECTION 310 REQUIREMENTS. W3. CONDUIT SHALL HAVE A MAXIMUM OF 4 BENDS WITHOUT A JUNCTION BOX TO PREVENT DAMAGE TO CABLE DURING PUWNG. THE EC SHALL PIGTAIL #12 PULL WIRE AT EACH END FOR INSTALLER TO PULL CABLE. ALL LOW VOLTAGE CONDUIT STUB -UPS SHALL BE PROVIDED WITH A BUSHING. W4• MINIMUM WIRE SIZE SHALL BE #12 AWG COPPER UNLESS NOTED OTHERWISE. MINIMUM CONDUIT SIZE SHALL BE 1/2" UNLESS NOTED OTHERWISE. WIRES INSTALLED UNDERGROUND OR OUTDOORS SHALL BE THW. W5. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID COPPER. CONDUCTORS #8 AND LARGER SHALL BE STRANDED COPPER. ALUMINUM CONDUCTORS SHALL NOT BE UTILIZED FOR FEEDER OR BRANCH CIRCUIT DISTRIBUTION. W6. W7. RACEWAYS SHALL BE ANY OF THE FOLLOWING MATERIALS, INSTALLED IN ACCORDANCE WITH ALL APPUCABLE CODES: OUTDOORS: (FOR SPECIFIC APPUCATIONS AND APPROPRIATE FITTINGS, SEE TABLE W8) 1. EXPOSED: RMC, IMC. 2. CONCEALED: RMC, IMC. 3. BELOW GRADE, SINGLE RUN: RNC, RMC. 4. BELOW GRADE, GROUPED: RNC, RMC. 5. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAUUC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR -DRIVEN EQUIPMENT): LFMC. 6. BOXES AND ENCLOSURES: NEMA 250, TYPE 3R OR 4. INDOORS: (FOR SPECIFIC APPUCATIONS AIM APPROPRIATE FrrnNGS, SEE TABLE W8) 1. EXPOSED: EMT, INC. 2. CONCEALED: EMT, IMC. 3. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAUUC, SOLENOID, OR MOTOR -DRIVEN EQUIPMENT): FMC; EXCEPT USE LFMC IN DAMP OR WET 4. DAMP OR WET LOCATIONS: RIGID STEEL CONDUIT. 5. BOXES AND ENCLOSURES: NEMA 250, TYPE 1, EXCEPT AS FOLLOWS: A. DAMP, WET NEMA 250, TYPE 4, STAINLESS STEEL ALL DEVICE CONNECTIONS SHALL BE MADE ON SCREW TYPE TERMINALS. NO PUSH -TYPE CLAMPING CONNECTORS OR "BACK -WIRING" WILL BE ALLOWED UNLESS THE WIRE CONNECTION IS TIGHTENED WITH A SCREW. PNEUMATIC, ELECTRIC LOCATIONS. OR KITCHEN LOCATIONS: UTILITIES: U1 • INCOMING SERVICE IS EXISTING 208Y/120V, 3 PHASE, 4 WIRE. LIGHTING: L1. EC SHALL VERIFY THAT NOT MORE THAN 3% VOLTAGE DROP EXISTS FROM THE UGHTING PANEL TO ANY EXTERIOR UGHTING FIXTURE OR SIGNAGE BALLAST. L2. EC SHALL VERIFY ALL TAP SETTINGS FOR H.I.D. UGHTING FIXTURES (IF APPUCABLE) AND MAKE ANY NECESSARY CORRECTIONS PRIOR TO INSTALLATION. L3. EC SHALL FIELD VERIFY THAT UGHT FIXTURES DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE GC BEFORE THE THE INSTALLATION OF SUCH FIXTURE(S). EC SHALL COORDINATE LOCATIONS OF ALL LIGHT FIXTURES IN DINING AREA WITH FINAL SEATING AND DECOR PLANS. L4. IF PC -POS CASH REGISTER SYSTEM IS INSTALLED, EC SHALL RELOCATE FIXTURES ABOVE FRONT COUNTER TO AVOID GLARE ON THE CASH REGISTER SCREENS. EC SHALL INSTALL CABLE WHIP TO FIXTURES SO THAT FIXTURE MAY BE RELOCATED FOUR FEET WITHOUT DISCONNECTING CABLE WHIP. L5. EC SHALL COORDINATE LOCATION OF ALL EXTERIOR UGHTS WITH McDONALD'S PROJECT MANAGER TO AVOID INTERFERENCE WITH ANY CORBELS, TRUSSES, BEAMS OR OTHER SPECIAL EXTERIOR TREATMENTS. INSTALL UGHT FIXTURES WITH CORRECT ORIENTATION PER MANUFACTURER'S INSTRUCTIONS L6. THE USE OF "MC" CABLE IN LENGTHS OF 6 FEET OR LESS (WHERE PERMITTED BY LOCAL CODES) SHALL BE ALLOWED FOR WIRING TO INTERIOR UGHTING FIXTURES. "ROMEX" OR "BX" SHALL NOT BE USED. L7. ALL LIGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. L8. UGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL OF ILLUMINATION. LAMP SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS SHALL BE APPROVED IN WRITING BY McDONALD'S CORPORATION. L9. EC SHALL VERIFY THAT NOT MORE THAN 3% VOLTAGE DROP EXISTS FROM THE UGHTING PANEL TO ANY LIGHTING FIXTURE OR SIGNAGE BALLAST. ELECTRICAL PANELS: p1. THE EC SHALL BE RESPONSIBLE FOR THE PROPER IDENTIFICATION AND LABELING OF ALL CIRCUIT BREAKERS. EACH PANEL SHALL BE PROVIDED WITH AN ACCURATE TYPEWRITTEN CIRCUIT DIRECTORY AT THE CONCLUSION OF THE PROJECT AND PRIOR TO RESTAURANT OPENING. ELECTRICAL SPECIFICATION \OTES: E1. FURNISH AND INSTALL ALL LABOR, TOOLS, MATERIAL, . EQUIPMENT,SERVICES, AND RELATED ACCESSORIES' NECESSARY FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN ON THE DRAWINGS, SPECIFIED IN THE NOTES, AND REQUIRED BY LOCAL CODE AUTHORITIES. E2. ALL WORK SHALL COMPLY WITH THE LOCAL CODES AND THEIR GOVERNING AUTHORITIES. E3. OBTAIN AND PAY FOR ALL PERMITS AND FEES RELATING TO ELECTRICAL SYSTEM. E4. IT IS INTENDED THAT ALL ITEMS . OF WORK AND SYSTEMS . BE FURNISHED AND INSTALLED COMPLETE IN ALL DETAILS, READY FOR SATISFACTORY OPERATION AND SERVICE. APPARATUS REQUIRED SHALL BE FURNISHED, EVEN THOUGH NOT SPECIFICALLY MENTIONED HEREIN, OR SHOWN ON THE DRAWINGS. E5. PROVIDE GROUNDING OF ELECTRICAL WORK IN STRICT ACCORDANCE WITH THE APPLICABLE CODES AND THEIR AUTHORITIES. E6. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO ANY INSTALLATION. E7. PROVIDE CODE APPROVED CLEARANCES AROUND ELECTRICAL EQUIPMENT. E8. MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL CONFORM TO THE N.E.M.A., NATIONAL ELECTRICAL CODE (NEC), AND UNDERWRITERS LABORATORIES (UL) STANDARDS IN EVERY CASE, WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED. E9. PROVIDE EXCAVATION AND BACKFIWNG REQUIRED FOR THE INSTALLATION OF ANY AND ALL PARTS OF THE ELECTRICAL WORK. PROVIDE SHEATHING, BRACING, AND OPERATE PUMPING EQUIPMENT, IF REQUIRED, FOR THE EXCAVATION PORTION OF THE ELECTRICAL WORK. E10. IL TING - AFTER WIRES ARE IN PLACE AND CONNECTED TO DEVICES AND EQUIPMENT, THE SYSTEM SHALL BE TESTED FOR SHORTS AND GROUNDS. ALL HOT WIRES, IF SHORTED OR GROUNDED, SHALL BE REMOVED AND REPLACED. El 1. ALL METERS, INSTRUMENTS, CABLE CONNECTION, EQUIPMENT, OR APPARATUS NECESSARY FOR MAKING ALL TESTS, SHALL BE FURNISHED BY THIS CONTRACTOR AT HIS OWN EXPENSE. El 2. AFTER THE COMPLETION OF THE INSTALLATION, THE ENTIRE SYSTEM SHALL BE THOROUGHLY CLEANED. CLEAN ALL FOREIGN MATTER, PAINT, OIL DIRT, UN -REQUIRED LABELS, GREASE, AND STICKERS FROM FIXTURES AND EQUIPMENT. REMOVE FROM THE PREMISES ALL RUBBISH, DEBRIS, ETC. ACCUMULATED BY THE ELECTRICAL INSTALLATION. El 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EQUIPMENT AND SYSTEMS AGAINST HARMFUL EXPOSURE, OR ACCUMULATION OF DUST/MOISTURE, FLOODING, CORROSION, OR OTHER FORMS OF DAMAGE. CLEAN AND RESTORE DAMAGED FINISHES AND EQUIPMENT TO PLACE INSTALLATION IN A LIKE -NEW CONDITION. El 4. SHOP DRAWINGS SHALL BE SUBMITTED FOR LIGHTING FIXTURES, PANELBOARDS, SWITCHBOARDS, TRANSFORMERS, DISTRIBUTION EQUIPMENT, WIRING DEVICES, AND RELATED EQUIPMENT. El 5. PROVIDE SLEEVES IN WALLS AND FLOOR SLABS FOR THE PASSAGE OF ALL CONDUITS, PIPES, AND DUCTS. SLEEVES SHALL BE SET IN PLACE IN SUFFICIENT TIME, AHEAD OF CONCRETE WORK, SO AS NOT TO DELAY THAT WORK. El 6. PERMANENT RECORDS - UPON COMPLETION OF INSTALLATION, FURNISH TO OWNER WIRING DIAGRAMS OF SPECIAL EQUIPMENT, LOW VOLTAGE SYSTEMS AND CONTROLS ALONG WITH RECORD SEPIA DRAWINGS. CATALOGS AND OPERATING INSTRUCTIONS FOR ALL EQUIPMENT AND CONTROLS SHALL BE ASSEMBLED, BOUND, AND GIVEN TO OWNER AS A GUIDE FOR FUTURE OPERATION AND REPAIR. E17. GUARANTEE - ALL ITEMS, MATERIALS, AND WORKMANSHIP FURNISHED UNDER THIS SPECIFICATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR, AFTER ACCEPTANCE OF THE WORK AS EVIDENCED BY THE DATE OF FINAL CERTIFICATE. ANY DEFECTIVE MATERIAL OR FAULTY WORKMANSHIP SHALL BE REPLACED WITHOUT COST TO OWNER. El 8. TEMPORARY SERVICES - ARRANGE FOR SOURCES OF TEMPORARY CONSTRUCTION SERVICES. SUCH SERVICES SHALL BE NOMINALLY 120/208 VOLT, 3 PHASE, 4 WIRE FROM WHICH A COMPLETE SYSTEM OF TEMPORARY POWER AND UGHTING SHALL BE INSTALLED FOR ALL CONSTRUCTION NEEDS. El 9. THE CONTRACTOR SHALL INCLUDE IN BID AN ALLOWANCE FOR THE FOLLOWING ADDITIONAL UFE SAFETY DEVICES, INCLUDING INSTALLATION AND ALL CONDUIT AND WIRE, FOR ADDITIONAL DEVICES AS MAY BE REQUIRED BY THE REVIEW OF THE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL PROVIDE A UNIT PRICE FOR EACH FOR QUANTITY ADJUSTMENT. E20. NUMBERED CIRCUITS SHOWN ON PLAN ARE FOR THE CONVEYANCE OF DESIGN INTENT ONLY. ACTUAL FIELD CONDTIONS WILL AFFECT CIRCUITRY. INDICATE THE ACTUAL CIRCUIT NUMBERS INSTALLED ON THE "AS -BUILT" DRAWINGS. E21. CONDUIT SHALL BE AS MANUFACTURED BY AWED, TRIANGLE OR APPROVED EQUAL. E22. WHERE EXISTING CONDUIT IS SHOWN ON THE DRAWINGS, IT IS SHOWN DIAGRAMMATICALLY. THE EXACT ROUTING OF THE EXISTING CONDUIT SHALL BE DETERMINED ON THE JOB SITE BY THE CONTRACTOR. E23. ALL CONDUIT AND WIRING SHALL BE CONCEALED WHEREVER POSSIBLE. WHERE CONDUIT AND WIRE CANNOT BE CONCEALED, PROVIDE WIREMOLD OR SURFACE MOUNTED CONDUIT ROUTED AS DIRECTED BY THE ARCHITECT. E24. ` ALL EXPOSED CONDUITS SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO STRUCTURAL MEMBERS. CAREFULLY COORDINATE EXACT ROUTING WITH THE ARCHITECT'S REPRESENTATIVE, IN THE FIELD, PRIOR TO ANY INSTALLATION. E25. ALL CONDUITS SHALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. CONDUIT SHALL NOT BE SUPPORTED FROM VENTILATING DUCTS, MECHANICAL PIPING, SUSPENDED CEIUNG GRIDS, OR THEIR HANGERS. E26. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, ENGINEER, AND PROJECT MANAGER IN WRITING OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES, OR REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. E27. OUTLET, PULL AND JUNCTION BOXES SHALL BE 12 GAUGE, OR HEAVIER, STEEL, SHERARDIZED WITH REMOVABLE KNOCKOUTS. BOXES SHALL BE AS MANUFACTURED BY APPLETON, STEEL CITY, OR RAYCO. E28. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY, QUICK -MAKE, QUICK -BREAK TYPE IN NEMA I ENCLOSURE. SWITCHES SHALL BE AS MANUFACTURED BY SQUARE D, EATON, SIEMENS OR GENERAL ELECTRIC. E29. FURNISH AND INSTALL ALL FUSES AS MANUFACTURED BY BUSSMAN. FUSES SHALL BE DUAL ELEMENT TYPE UNLESS NOTED OTHERWISE. E30. WIRING DEVICES SHALL BE SPECIFICATION GRADE. TOGGLE SWITCHES WILL BE QUIET TYPE RATED 20AMP, 120 VOLT. DUPLEX RECEPTACLES SHALL BE RATED 20AMP, 120 VOLT GROUNDED. SPECIAL RECEPTACLES SHALL BE PROVIDED AS REQUIRED. COVERPLATE FINISH FOR ALL DEVICES SHALL BE AS DIRECTED BY ARCHITECT. WIRING DEVICES SHALL BE AS MANUFACTURED BY PASS & SEYMOUR, HUBBELL OR GENERAL ELECTRIC. E31. EXISTING CONDITIONS OF ALL EXISTING BUILDING EQUIPMENT, DEVICES, FIXTURES, AND SYSTEMS THAT REQUIRE REWIRING, REUSE, RELOCATION, OR REFURBISHING AS PER DRAWINGS AND SPECIFICATIONS SHALL BE FIELD VERIFIED BY THE E.C. PRIOR TO COMMENCEMENT OF ANY WORK TO BE COMPLETELY OPERATIONAL. EC. SHALL SUBMIT A WRITTEN STATEMENT AND ITEMIZED LISTING OF ALL EXISTING CONDITIONS OF THE FOLLOWING, ALTHOUGH NOT LIMITED TO THOSE USTED: A. HVAC EQUIPMENT B. EXIT SIGNS AND EMERGENCY UGHTING FIXTURES C. LIFE SAFETY/FIRE ALARM SYSTEM DEVICES D. LIGHTING AND RECEPTACLE DEVICES. THE WRITTEN STATEMENT SHALL BE SUBMITTED TO THE PROJECT MANAGER, ARCHITECT, AND ENGINEER PRIOR TO WORK. IN THE EVENT THAT THE CONTRACTOR COMMENCES WORK WITHOUT SUBMITTAL THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY AND COST TO MAINTAIN THE ABOVE IN GOOD WORKING ORDER AND CONDITION. TABLE W6: LOCATION 208V. LOW ENERGY* EXPOSED INDOORS < 1" EMT COMPRESS. FTGS >1.25" INC THREADED FTGS EMT COMPR. FTGS OUTDOORS RMC OR IMC THREADED FTGS RMC OR INC THREADED FTGS CONCEALED WALLS <2" EMT SET SCREW FIGS >2.5" INC THREADED FTGS EMT 1/2"- 2" SET SCREW FIGS 2.5" - 4" COMPR. FIGS AIR HANDUNG CEILING/ SPACE <2" EMT COMPR. FTGS >2.5" IMC THREADED. FTGS EMT COMPR. FTGS NON AIR HNDLNG CEILING/ SPACE <2" EMT SET SCREW FTGS >2.5" IMC THREADED. FTGS EMT " - 2" SET SCREW FIGS 2.5"- 4" COMPR. FTGS BELOW GRADE INTERIOR INC THREADED FTGS OR SCHEDULE 40 OR 80 PVC INC THREADED FTGS SCHEDULE 40 OR 80 PVC EXTERIOR SCHEDULE 40 OR 80 PVC OR RMC THREADED FTGS SCHEDULE 40 OR 80 PVC OR RMC THREADED FIGS J -BOX FOR POWER PULL BOX FOR DATA E32. ALL EQUIPMENT LOCATED OUTDOORS SHALL BE WEATHERPROOF TYPE. E33. EXPANSION FITTINGS - PROVIDE EXPANSION FITTINGS FOR CONDUITS CROSSING EXPANSION JOINTS. E34. CONNECTIONS - ALL MAIN FEEDER CONNECTIONS SHALL BE MADE WITH SOLDERLESS CONNECTORS, BOLTED TYPE. SMALLER WIRE SPUCES SHALL BE MADE WITH PRESSURE TYPE CONNECTORS - MINNESOTA MINING "SKOTCHLOCKS" OR IDEAL "WINGNUTS". E35. PROPERLY LABEL AU. PANELBOARD DIRECTORIES FOR NEW WORK INVOLVED. DIRECTORIES SHALL BE TYPEWRITTEN. E36. FURNISH AND INSTALL UGHTING FIXTURES COMPLETE WITH LAMPS, HANGERS, AND CONTROLS AS SHOWN ON THE DRAWINGS AND IN THE LIGHTING FIXTURE SCHEDULE. E37. ALL NEW CIRCUIT BREAKERS FOR EXISTING PANELBOARDS AND DISTRIBUTION PANELBOARDS SHALL MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND CIRCUIT BREAKER TYPE. ALL CIRCUIT BREAKERS SHALL BE BOLT ON TYPE. AIC RATING OF NEW CIRCUIT BREAKER SHALL MATCH AIC RATING OF PANELBOARD IN WHICH IT IS INSTALLED. WHERE SERIES RATED TYPE CIRCUIT BREAKERS ARE USED, NEW CIRCUIT BREAKERS SHALL BE INSTALLED SO AS TO MAINTAIN THE UL SERIES RATING OF THE ENTIRE SYSTEM. THE CONTRACTOR SHALL PROVIDE A NEW TYPEWRITTEN PANEL DIRECTORY FOR EACH PANEL CHANGED AT THE COMPLETION OF THE PROJECT. EACH CIRCUIT BREAKER SHALL BE LABELED TO IDENTIFY LOAD TYPE AND LOCATION. E38. THE CONTRACTOR SHALL REMOVE EXISTING CEILING SYSTEMS, IF REQUIRED, TO INSTALL NEW CONDUIT AND WIRING. AT COMPLETION OF NEW WORK, THIS CONTRACTOR SHALL REPLACE AND MATCH FINISH OF THE EXISTING CEIUNG. E39. COORDINATE STAGING OF MATERIAL WITH BUILDING MANAGEMENT REPRESENTATIVE AT TIME OF BIDDING. E40. THE SUSPENDED CEIUNG SPACE IS UTIUZED AS A PLENUM SPACE. ALL WORK SHALL COMPLY WITH LOCAL CODE REQUIREMENTS FOR INSTALLATION IN PLENUM CEIUNG SPACES. E41. ALL CUTTING, DRIWNG, AND PATCHING OF MASONRY, DRYWALL, CONCRETE, STEEL, OR IRON WORK BELONGING TO THE BUILDING SHALL BE DONE BY THIS CONTRACTOR IN ORDER THAT WORK MAY BE PROPERLY INSTALLED. UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTION OF THE ARCHITECT/ENGINEER OR THEIR REPRESENTATIVE. E42. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW AND OF COMMERCIAL GRADE UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED ON DRAWINGS. E43. BRANCH CIRCUIT HOMERUN WIRING: A. GENERAL PURPOSE BRANCH CIRCUIT HOMERUNS CONSISTING OF TWO NETWORKS SHALL HAVE PHASE, NEUTRAL AND GROUND CONDUCTORS INCREASED TO NUMBER 10 AWG, THWN AS A MINIMUM. WHERE HOMERUN (ONE OR MORE NETWORKS) EXCEEDS 100 LINEAR FEET, CONDUCTOR SIZE SHALL BE INCREASED ONE TRADE SIZE. B. HOMERUN LENGTH SHALL BEGIN AT THE CENTRAL POINT OF ALL DISTRIBUTED CIRCUITS TO THE PANELBOARD CIRCUIT BREAKER. E44. CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS FOR ELECTRICAL POWER SYSTEMS WITHIN 30 DAYS OF SYSTEM ACCEPTANCE. E45. CONTRACTOR SHALL FURNISH OPERATION & MAINTENANCE INSTRUCTIONS FOR SYSTEMS AND EQUIPMENT TO THE BUILDING OWNER OR DESIGNATED REPRESENTATIVE. E46. CONTRACTOR SHALL PROVIDE WRITTEN VERIFICATION WITH COPY TO ENGINEER THAT LIGHTING SYSTEMS HAVE BEEN TESTED TO ENSURE PROPER CALIBRATION, ADJUSTMENT, PROGRAMMING AND OPERATION. iy-41 1 E4.0 MODULAR COUNTER RACEWAY (TYP.) N.T.S. SYMBOL CATALOG # DESCRIPTION QUANTITY -- RECEPTACLE COVERPLATE WITH ORANGE, TWIST LOCK, ISOLATED GROUND DUPLEX RECEPTACLE 1 PER RECEPTACLE IN sio sS G /ANAL HBLALU57DR & IG5262 RECEPTACLE COVERPLATE WITH ORANGE, STRAIGHT BLADE, ISOLATED GROUND DUPLEX RECEPTACLE 1 PER RECEPTACLE No NE 07/18/2017 05/05/2018 -.all HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT & 1 FOR ANALOG WIRELESS OPTION I 1 HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY I 1 HBLALU5000602M290 2' SECTION OF RACEWAY. INCLUDES COUPLERS 1 FOR PICK UP COUNTER AND AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1' LESS THEN COUNTER LENGTH 1 1 UBBELL 4' SECTION OF RACEWAY, INCLUDES COUPLERS 11 11 Il II 1 J HBLALU5000605M290 5' SECTION OF RACEWAY, INCLUDES COUPLERS AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1' LESS THEN COUNTER LENGTH HBLALU5010B BLANK END FITTING AS NEEDED ® HBLALU5000BOXM290 SERVICE ENTRANCE FITTING & BUSHING FOR DATA CABLES AS NEEDED N/A HBLALU5701 COUPLER (INCLUDED WITH RACEWAY SECTION) RECEIVE 1 PAIR PER RACEWAY SECTION N/A HBLALU5709 GROUND ADAPTER AS NEEDED r U Jl.Hu ORB sc RACEWAY 0 (TO BE 1' u - <. m LESS THEN M 1 GREENFIELD CONDUIT COUNTER LENGTH) HUBBELL HBLALU5000B02M290 RACEWAY (2' LEN 311-1) DATA iy-41 1 E4.0 MODULAR COUNTER RACEWAY (TYP.) N.T.S. SYMBOL CATALOG # DESCRIPTION QUANTITY NOTES: 1. RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. 2. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 City of Tukwila BUILDING DIV'S;UN RECEIVED TTY OF TUKWILA AUG 0 9 2017 CENTER EPARATE ERMIT AND APPROVAL EOURED seven MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@seva nsolutions.com www.sevansolutlons.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS SEAL HBLALU57DR & IG4700 RECEPTACLE COVERPLATE WITH ORANGE, TWIST LOCK, ISOLATED GROUND DUPLEX RECEPTACLE 1 PER RECEPTACLE IN sio sS G /ANAL HBLALU57DR & IG5262 RECEPTACLE COVERPLATE WITH ORANGE, STRAIGHT BLADE, ISOLATED GROUND DUPLEX RECEPTACLE 1 PER RECEPTACLE No NE 07/18/2017 05/05/2018 -.all HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT & 1 FOR ANALOG WIRELESS OPTION I 1 HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY I 1 HBLALU5000602M290 2' SECTION OF RACEWAY. INCLUDES COUPLERS 1 FOR PICK UP COUNTER AND AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1' LESS THEN COUNTER LENGTH 1 1 HBLALU5000B04M290 4' SECTION OF RACEWAY, INCLUDES COUPLERS AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1' LESS THEN COUNTER LENGTH 1 J HBLALU5000605M290 5' SECTION OF RACEWAY, INCLUDES COUPLERS AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1' LESS THEN COUNTER LENGTH HBLALU5010B BLANK END FITTING AS NEEDED ® HBLALU5010B2M2 SERVICE ENTRANCE FITTING & BUSHING FOR DATA CABLES AS NEEDED N/A HBLALU5701 COUPLER (INCLUDED WITH RACEWAY SECTION) RECEIVE 1 PAIR PER RACEWAY SECTION N/A HBLALU5709 GROUND ADAPTER AS NEEDED r NOTES: 1. RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. 2. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 City of Tukwila BUILDING DIV'S;UN RECEIVED TTY OF TUKWILA AUG 0 9 2017 CENTER EPARATE ERMIT AND APPROVAL EOURED seven MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734367-4445 Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 Info@seva nsolutions.com www.sevansolutlons.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS SEAL PROJECT NO.: IP A z 1, *GistEg�9 sS G /ANAL SR EXPIRES 0 7 05 i 8 DD SIGN . l 07/18/2017 05/05/2018 DATF FXPIRATION DATF CERTIFICATION PREPARED FOR 1McDonald's USA LLThese drawingsand specifications ore the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a Tater time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 SHEET TITLE GENERAL ELECTRICAL NOTES SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/19/2017 DRAWN BY: SR REVIEWED BY: DD NATIONAL STORE # 11411 SHEET NUMBER E3.0 Electrical SF: 1.00 CC JN: H:\ 17021.43 FN: E3.0-SPEC_TUKWILLA,WA 10:55am cad03 0 N ip >, D CD 0 -1 I W 0 0 0 CD W z LU 0 W .tL ' 21515 a intron fY Code Complian Fi r Ci u n iudin 2. over 3i t a 111 wised Auaui 2016 Project Info CompllanCe ' forms do not' require a password to use. Instructional and calculating cells are write - protected. Project The: McDonald's - Tukwiis, WA Date 7/19/2016 Applicant 'nlannation. 'Provide contact information for individual who can l respond to inquiries about compliance fair, information provided. For Building Department Use CompanyName: DICKERSON ENGINEERING, INC CompanyAddress: 3343 NORTH RIDGEAVE ARLINGTON HEIGHTS, 1L60004 Applicant slame: DAVIS DICKERSON Applicant phone: (847) 966-0290 Applicant Email: DAVIS. DICKERSONj?,CDEI-PE.COM Project Description oI pon [] New Building LI Addition U Alteration U Plans Included Include PROJ-SUM born (included in envelope forms norkbook) with lighting comp/ iarce forms. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with an appl cable provisions as a stand alone new construction project ❑ ❑ Lighting systems in addition are combined with existirg building lighting systems to demonstrate compliance ❑ C Addition is combh'ed with existing: For interior lightingprojects, include new + existing f rterior lighting fixture wattage in Proposed Lighting Wattage table in LT3-INT-BLD or LTG -!NT -SPACE fare For exterior lighting projects, include new + existing 3xteriorlighting fixture wattage inProposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT tom Interior and Exterior Lighting Alterations Sect all Lighting Power Control elements that of the retrofit project. If combination of sceswherele=than 50% of the existing fixtures in some spaces, and 50% fixtures am replaced in Provide separate lighting omv, a separate for the compconditions. Spaces undergoing type of retrofit may be lighting power compliance Refer to Section C503.6 requirements. AN alteration lighting controls commissioned per C408.3. and Ligating apply to the scope project includes a are replaced or mor of the others, then power two retnfil tie same combined 7rto one farm. for addtonal shall be befog male to lighting space are not Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of exiving are replaced C405.1 ❑ ❑ 0 C405.1 Less than 50% of misting are replaced C405.2,3 40 C405.2.1.1 C405.2.2.2 C405.2.4 0405.2.5 Manual controls ❑ il❑ - Item 6 Lamp and/or ballastreplacement only - existing total wattage not increased 0405:2.2.1 0405:2.2.2 C405:2:3 ❑ C II Lighting Pourer Calculation - indicate compliance pat taken 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shal comply with Total LPA per Sections C#05.4.2 and C405.5.2. Include m -w +existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -SLD, LTG-1NT-SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures .stall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table to LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number ofluminaires for arterior spaces and parking garages, and total installed wattage for exterior luminaires, Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) Indicate locations vhere automatic shutoff is provided by other methods (occupanlysensor or digital timer switch) or tehich time switch control exception applies EXISTING TO REMAIN 0 151 ■ Occupancy sensor controls Indicate on plans tte spaces served by occupancy sensors; New or moved lighthg panel 0 indicate whether otcu sensor controls are configured to anc p Y be manual -on, athematic 50% -on, or serve a space eligible for automatic 100% -on per 0 • NA Interior space is reconfigured - luminaires unchanged or relocated only Occupancy sensor controls - warehouses indloate aisieways and open areas Inwarehouse spaces provided with occu)ancy sensor controls that reduce lighting power by5096 Include alt luminaires In fighting fixture schedule; indicate fixture types, tamps, ballasts, and manufacturer's rated watts per fixture; Ii NA New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, dayhght responsive catt►ols per C405.2.4 and application specific lighting controls per C405.25. For exterior lighting, provide required controls per C405.2.7- New or moved parel - Provide all applicable ffghtirg controls as noted for New Whiny and automatic time switch controls per C405.2.2. Reconfigured intelfor space - Provide all required fighting controls that apply to a new interior space. Application specific!ghting control provisions per C405.2.5 do fiat apply to reconfigured spaces. • No changes are the interloror exterior systems and existing uses and configuration changed. Change of Space Use ❑ Existing hteriol lighting systems in areas under -going a change in space use are apgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2) identify interior spaces requiring LPD upgrade to the ;urrerat Code in Proposed Lighting Wattage table in LTG -INT -BLD or LT3-INT-SPACE form. ,tt I # ,1>3t,y.34JY,w Ll hurl M >otOr AS,t,N',ry{X`,3�c..,: clistP.°�. C� P It:ChL' k aI� lac rel l errri LTG CHI„ 2015 Washington State nergy Code Compliance orntsfar ommerctel Buit, togs inducting t22, R3, Rd aver 3 stories and ail R1 Re sed August 2016 Project Title: McDonald's - Tukwila, WA IDate '7/19/2016 The following information is necessary to check a permit application fa- compliance with the lighting, motor, and electricalrequirements Washington State Energy Code, Commercial Provisions. in the Applicability (yes,no,na) Code Section Component Compliance infomntion required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS C405.2.5 - Item 3 pea C405.2 Lighting controls, general g For all lighting fixtwes, indicate lighting control method on plans for spaces and !tithing zone(s)served, or exception taken P B 9 P E2 0 C405.2:5 - item 4 NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans al fixtures provided vtiith LLLC in lieu of C405.2 lighting cortrols; provide description of control oapabil les and pelfomance parameters 8 C405.2.5 - item 5 NA C405.1 Lighting in dwelling units Forermanent installed lighting fixtures m dwelling units, p N tndtcate lighting control method on ptans for spaces and lighting zone(s) sewed, or demonstrate compliance with high efficacy exception Indicate on plans tat non -visual lighting are controlled independently independentlyfromboth general area lighting and other Fighting applications within he same space; C405.1 Yes C405.2,3 40 C405.2.1.1 C405.2.2.2 C405.2.4 0405.2.5 Manual controls Indicate on lanstte method of manual lighting control (whether p combined with occipancy sensor, automatic light reduction, daylight responsive orspecikcapplication controls), location of manual control device and area or speclece application it serves E2.0 - Item 6 Yes 0405:2.2.1 0405:2.2.2 C405:2:3 Manual Interior iighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether load is reduced via occupancy sensorsor daylight responsive controls E2.0 Lighting Pourer Calculation - indicate compliance pat taken NA 5 C40 .2.2 Method of automatic shut-off sonnet Indicate on plans t•e method of automatic shut-off control during unoccupied rereads (occupancy sensor or time switch) for all ligating zones; EXISTING TO RemAiN E2.0 Indicate locations vhere automatic shutoff is provided by other methods (occupanlysensor or digital timer switch) or tehich time switch control exception applies EXISTING TO REMAIN Space -By -Space Method NA C405.2.1 0405.2.1.1 Occupancy sensor controls Indicate on plans tte spaces served by occupancy sensors; 2354 NA indicate whether otcu sensor controls are configured to anc p Y be manual -on, athematic 50% -on, or serve a space eligible for automatic 100% -on per Exterior fighting controls Indicate on exteriorlyBhtinBP lans and fixture schedules the automatic Iightingontrol method, control sequence, and locations served;. NA C405.2.1.2 Occupancy sensor controls - warehouses indloate aisieways and open areas Inwarehouse spaces provided with occu)ancy sensor controls that reduce lighting power by5096 Include alt luminaires In fighting fixture schedule; indicate fixture types, tamps, ballasts, and manufacturer's rated watts per fixture; For all otherexierialighting, Indicate automatic controls shut off lighting as a functici of available daylight; include control sequence that alsoreduces ligating power by at least 30% between 12am-Ban, or from 1 hour after closing to 1 hour before opening, or rased upon motion sensor NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used Exterierbuiiding grounds lighting controls For building grouncs`fixtures greater than 100 watts, indicate on plans whetherfixtutes have efficacy greater than 60 lumens or; are controlled by nation sensor, or are exempt lighting per C405,5.2 NA C405.2.2.1 Automatictime swatch controls indicate locations doverride switches on plans and the lighting xone(s)served, incude'area sq. ft Area controls - Masterdcontrol switches and circuit power limit Indicate location(s)of master control switch(es) intended to control multiple independent switches; circut breaker may not be used as a master control switch; Yes C405.2.4.2 0405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary ani secondary sidelight daylight zone areas on plans, include sq. it; E2.0 NA Indicate datlight zone areas on plans, include sq. ft.; Enhanced digital lighting controls To complywith adctionai efficiency package option, indicate on plans alt interior digiting fodures that are individually addressed and provided with ontinuous dimming, or exception taken; For small vertical fenestration assemblies (rough opening tess than 10 percent of primary daylight zone) where daylight responsive control: are not required, provide fenestration area to daylight zone cabulation(s) Complete required:ompiiance form - proposed wattage for atelier lighting plu; base site allowed does not exceed maximum allowed Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90%to comptywlth additional efficiency package option) Yea C405.2.4 Daylight responsive controls Mdicate on plans lighting zone(s) served by daylight responsive controls: E2.0 If claiming fighting rystem commissioning exemption provide supporting calculaton: Identify applicable commissioning documentation requirements per Section 0408 a eligibility for exception Provide written procedures for functional testing of all automatic controls and descrne the expected system response Identify sidelight ani toplight daylight zones that are not provided with daylight controls and the exoeption(s) that apply; Indicate on plans tie lighting load reduction method - eontinuous dimming, or stepped dimming that provides at least two even steps betveen 0%-100% of rated power; E2.0 Indicate that dayligit sensing controls are configured to completely shut offal) controlled lights in the lighting zone Yea C405.2.5 Additional controls - Specific application lighting controls Identify spaces anc lighting fixtures on plans that require specific applicationlighting controls per this section E2.0 NA 0405.2:5 - Items 1&2 Display and accent lighting Indicate on plans tat clisplayand accent lighting, and display case fighting are cottoned independently torn both general area lighting and ober lighting applications within the same space; Indicate manual ant automatic lighting control method 2)15 ashinatc Sta Code Compliance For at = tt ineatin° gs 9 , 4 d 1 Revised Auraust2016 Project Title: McDonald's - Tukw•la, WA 'Date 7/19/2016 Interior Lighting System Description 1 i , i ; 1 , Interior Lighting Power Allowance Method ❑ Building Area Method E Space -by -space Method Select methal used is project. Interior Lighting Controls 7/19/2016 ❑ All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminare Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhance -t digital lighting controls To comply with C40f.4, no less than 9096 of the total Installed inferior fighting power stall comply wxih the required controls perC406.4. Dwelling Unit interior Lighting Permanently instalfedinterforlighting fixtures indwelling units comply with- C Q C405.2 thru C4055 Commercial Lighting Controls Ind LPA O C406.3 High Efficacy Lighting 0 Exterior Lighting System Description N/A p ,nza r n war.,, LI hti ,.:>',. o rel M > ::;,.rs:: ;,, ,;,s ,, , . ,...;., n ,.,,,.., , .., i. ., , p'+ 'J„ ;;', ,>,. .: z. ,>;;.., '.. 'An ."". i. s':. or ;arid I ctrlC ll Per It, h kil t P ., Code Comitance Forms fore Buil `Mctudi R2 R3, Rd over 3 s • ries and all RI P Ds rKt ,s , 3, eG,, '�H�Kt ",LTG. CHI.. T�': vN , ..r, n,r Revised August 2016 ug 15Washington ate Ener 20 Sl Energy Project Tide: McDonald's - Tukwila, WA 'Date 7/19/2016 to apermit application fa compliance thelihtin motor, and electricalrequirements The following information is necessary check app plighting, Washington State Energy Code, Commercial Provisions. q in the Applicability (yas,no,na) Code Section Component Compliance infnnnttion required in permit documents Location in DocumentsNotes Building Department Nn C405.2.5 - Item 3 Hotel/motel guest roams Indicate method of automatic control - vacancy or captive key control of all Installed luminaires and switched receptacles in guest room 0.710 1609 Nn C405.2:5 - item 4 Supplemental task pp IighCi g indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighteg 0.960 7 4 e 8 C405.2.5 - item 5 Lighting for non - visual applications Indicate on plans elglble non -visual lighting applications, include sq. ft. area ref each lighting control zone; TYPE-'P2'-'ENDANT LiGHT - LED STIX PENDANT 2 Indicate on plans tat non -visual lighting are controlled independently independentlyfromboth general area lighting and other Fighting applications within he same space; C405.1 192 Indicate method of manual lighting control and applicable automatic lighting orntrol MAC405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans tat lighting equipment for sale or demonstration are controlled independently from both general area lighting and otter lighting applications %delta the same space; C405.9.2 Escalators and " moving walks Indicate method ofnenual lighting control and applicable automatic lighting control Lighting Pourer Calculation - indicate compliance pat taken NA tenor C405.2.5 - Item 7 Means of egress lighting Identify on plans egess fixtures that function as both normal and emergency n means ofegress illumination E2.0 3042 Provide calculalionof lighting power density of total egress lighting; Space -By -Space Method Alkwance from If total egress lightieg power density is greater than 0.02 Kett ft., indicate on plans egress fixtures requiring automatic shut -of during unoccupied ieriods; Indicate method of automatic shut-off control fie 2354 NA C405,2.7 Exterior fighting controls Indicate on exteriorlyBhtinBP lans and fixture schedules the automatic Iightingontrol method, control sequence, and locations served;. EXTERIOR LIGHTING POWER & EFFICACY Nn For building facadeand landscape lighting, indicate automatic controls shut off ligating as a function of dawn/dusk and fixed opening/closine tine; Total connected exterior lighting power Include alt luminaires In fighting fixture schedule; indicate fixture types, tamps, ballasts, and manufacturer's rated watts per fixture; For all otherexierialighting, Indicate automatic controls shut off lighting as a functici of available daylight; include control sequence that alsoreduces ligating power by at least 30% between 12am-Ban, or from 1 hour after closing to 1 hour before opening, or rased upon motion sensor Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Wats mnd exceed Total Allowed Watts for Interior Lighting Total Proposed Watts Identify exterior aplications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; NA C405.5:1 Exterierbuiiding grounds lighting controls For building grouncs`fixtures greater than 100 watts, indicate on plans whetherfixtutes have efficacy greater than 60 lumens or; are controlled by nation sensor, or are exempt lighting per C405,5.2 Yes C405.2.5 Area controls - Masterdcontrol switches and circuit power limit Indicate location(s)of master control switch(es) intended to control multiple independent switches; circut breaker may not be used as a master control switch; E2.0 NA Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond' 80% Extenorbuilcin B grounds lighting For building game fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) infixture schedule NA C406,4 Enhanced digital lighting controls To complywith adctionai efficiency package option, indicate on plans alt interior digiting fodures that are individually addressed and provided with ontinuous dimming, or exception taken; Exteriorit htin 9 B power calculations Complete required:ompiiance form - proposed wattage for atelier lighting plu; base site allowed does not exceed maximum allowed Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90%to comptywlth additional efficiency package option) NA C405.13 C408.3 Lighting system functional testing If claiming fighting rystem commissioning exemption provide supporting calculaton: Identify applicable commissioning documentation requirements per Section 0408 a eligibility for exception Provide written procedures for functional testing of all automatic controls and descrne the expected system response 2015' anc arms for Commercial R2, R3, R4 over 3 Rev/ Au st 2016 Project Title: McDonald's •TukwIla, WA Date 7/19/2016 Calculation i Area NOTE 9 ( ()Addition ( ' Addition stand alone I + existing (1 Spaces "here < 50% of �a Spaces where >_ 50% of 0 -- luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type Q Standar/ C Additional Efficiency Package Option C C406.3 Reduced Interior Lighting Power To comply Math C406•3, the Proposed LPD shall be 25% lower than the TargetLPA, Refer to C446.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE 1 60 Location (plan #, room #) Space Type Ceiling Height NCIT 2 Gross Interior Area in ft' Allowed Watts per ft` Watts Allowed (watts/ft? x area) CiNING Dining area: Family dining area 41: 2266 0.710 1609 PLAY PLACE Gypnasium/ftness center: Playing area 1 R 0 776 0.960 7 4 e 8 0405:3 7 2 'CINING TYPE-'P2'-'ENDANT LiGHT - LED STIX PENDANT 2 96 C405.1 192 Ifhi high efficacy exception is applied p p topermanently nstalled B Y pi lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps b fixtures are high efficacy per 8404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% tc comply with exception). NA C406.3 Reduced lighting power density- edwellingffunit Tamp cac Y For projectwith dwelling units, to comply with additional efficiency package 7ption indicate in lighting fixture schedule if lamps in fixtures here efficacy rating of 60 lumens per watt or more. Calculate pe•centage of fixtures with (amps that have this efficacy rating (min95% to comply with option). C405.9.2 Escalators and " moving walks Indicate escalators comply with ASME A17.1iCSA'B44; automatic controls Ire configured to reduce operational speed to the minimumPe rnitted when not in use Lighting Pourer Calculation - indicate compliance pat taken NA C405:4.2.1 BuildingAresMethod Complete required sompliance'foms - proposed wattage per builoting area ' does lot exceed maximum allowed Wattage per building area. identfy)ocations of bulking areas on plans Lobby Art/Exhibit Display Allowance from LTG-INT-DSPLAY NO'-" Total Area Retail Display 3042 LTG -INT -DISPLAY Allowed Watts Space -By -Space Method Alkwance from Identify all cone -oiled and uncontrolled receptabtes on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, drplex devices, etc; fie 2354 Proposed Lighting Wattage Hu C a Location (plan #, room le 1CTE4. r Fixture Description Number of Fixtures Watts/ NOTE 7 Fbture The following information is necessary to check a permit application for can liancewith the lighting, motor, and eleceicalrequirements in the Washhgton State EnergyCode, Commercial Provisions. Watts Proposed CINING/PLAY- AREA TYPE - 'F12' - 6" LED DOWN LIGHT 60 13 Building Department Notes 750 CINING TYPE -'FI2A - 6" LED WALL WASH 4 12 E1,0 41: CINING TYPE -'F12S - 6" LED DOWN LIGHT IN/ SILVER TRIM 1'-, le 1 R 0 CINING TYPE -.P1'- 3ENDAhlT LIGHT - BEAN PENDANT 9 8 0405:3 7 2 'CINING TYPE-'P2'-'ENDANT LiGHT - LED STIX PENDANT 2 96 C405.1 192 Ifhi high efficacy exception is applied p p topermanently nstalled B Y pi lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps b fixtures are high efficacy per 8404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% tc comply with exception). NA C406.3 Reduced lighting power density- edwellingffunit Tamp cac Y For projectwith dwelling units, to comply with additional efficiency package 7ption indicate in lighting fixture schedule if lamps in fixtures here efficacy rating of 60 lumens per watt or more. Calculate pe•centage of fixtures with (amps that have this efficacy rating (min95% to comply with option). C405.9.2 Escalators and " moving walks Indicate escalators comply with ASME A17.1iCSA'B44; automatic controls Ire configured to reduce operational speed to the minimumPe rnitted when not in use Lighting Pourer Calculation - indicate compliance pat taken NA C405:4.2.1 BuildingAresMethod Complete required sompliance'foms - proposed wattage per builoting area ' does lot exceed maximum allowed Wattage per building area. identfy)ocations of bulking areas on plans Indicate all one-wa• down or reversible escalators are provided with a variable fregiencyregenerative drive Yes C405.4:2.2 Space -By -Space Method Complete required :omliancefoms-total proposedwatta e does not exceed maximum allowed wattage. identify locations of space types on dans, including renal display areas, lobby art & exhibit display anas, and ceiling heights as applicable Identify all cone -oiled and uncontrolled receptabtes on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, drplex devices, etc; fie C406.3 Red Emit lighting y power density To complywith addtional efficiency package option, demonstrate in conptianceforms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage viaBuilc'ln9 Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY Nn C405.5.2 Total connected exterior lighting power Include alt luminaires In fighting fixture schedule; indicate fixture types, tamps, ballasts, and manufacturer's rated watts per fixture; Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Wats mnd exceed Total Allowed Watts for Interior Lighting Total Proposed Watts Identify exterior aplications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; 1242 Interior Lighting Power Allowance COMPLIES Mote f - List t/ unique space types per Table C405.4.2(2) that occurin the project scope. Select space type category per from drop srwn menu. Note 2 - indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Tabe C405.4.2(2), Fodnotes d thru f Note 3 - List all motorised lighting 9xtures including exempt lighting equtpmerk and existing -to -remain fixtures. Note 4 - For proposed Fixture De cripfion, indicate fixture type, lanae type (e.g. T-8), number of lamps in the fixture, and ballast type (f fncfuded). For track fighting, fist the lenith of the track (in feet) in ackiition to the fixture, lamp, and ballast ioformation. Note 5 - For lighting equipment elgibie for exemption per C405.4.1, note exception number and leasee Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures . Wordily as existing in fixture description, Note 7 - For proposed Watts/Fixture enterthe luminaire wattage fro Unstated lamp and ballast using ,'nanufacturerorother seem ved .ounce. For luminaires with sciew-in amps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enterthe wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enterthe wattage limit of permanent dement kmifirg device. /dote 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting 'Unites in a Wilding addition may comply as a stand alone project, or they may be combined with the overall exist ng building lighting systems to denonserate compliance. Refer to 0502.1. b. For alterations and baling ackirtfons, pmvide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table If a buikfiing addition will comply as combined with the overall existing binding lighting systems, include all applicable exlstingSpace Types and gross interior areas. c. 1f less than 50% of exsting fighting fixtures will be replaced, provide total existing lighting wattage (prlo r to alteration) Olin space provided w z.. ,... >,,. .. .(,. 2.....:,. . :s a .. ,,, ,' Ll htl ons arid Electrical P Lightri �rrrilt Check ;P >: 2015 Washingkm St a nargy Code ' onset once onnstor'CommercialBuiidhgs ` - ixling 1 . R3, R4 over 3 stories and all ' 1 ,. ,..,,,, ..,. LT C1 -iii,. vised August 2016 Project Title: McDonald's -Tukwila, WA Date 7/19/2016 The following information is necessary to check a permit application for can liancewith the lighting, motor, and eleceicalrequirements in the Washhgton State EnergyCode, Commercial Provisions. Applicability (yes,no,nal Code Section Component Compliance information required in pennit documents _ Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yea C405.41 Cd05.4.1 Gd05.4:2 Tatatconnected interior lighting pawed Include all luminaires in lighting fixture schedule; indicate fcdure types, lamps, ballasts: and manufacturer's rated watts per fixture; E1,0 Identify spaces eligbloior Iighting power exemption on plans and ini com iance'orms; indicate the ecce tion a lied ill P PP C405.7 Dwelelectring unit electrical energy cansum tion p Identify lighting #in e ti merit ell time for lighting power exemption fy !� B q P g 9 g P in fixture schedule and in compliance forms; Indicate the exception applied; Indicate that exemFt lighting equipment is in addition to general area lighting and iscontrolled independently C405.8 Electric motor efficiency Yes 0405:3 Exit signs Indicate location ofexit signs on plans and rated watts per fixture in lighting leture schedule (maximum 5 watts per fixture) El0 Elevator cabs en C405.1 Lighting in dwelling units'- lamp efficacy Ifhi high efficacy exception is applied p p topermanently nstalled B Y pi lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps b fixtures are high efficacy per 8404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% tc comply with exception). NA C406.3 Reduced lighting power density- edwellingffunit Tamp cac Y For projectwith dwelling units, to comply with additional efficiency package 7ption indicate in lighting fixture schedule if lamps in fixtures here efficacy rating of 60 lumens per watt or more. Calculate pe•centage of fixtures with (amps that have this efficacy rating (min95% to comply with option). C405.9.2 Escalators and " moving walks Indicate escalators comply with ASME A17.1iCSA'B44; automatic controls Ire configured to reduce operational speed to the minimumPe rnitted when not in use Lighting Pourer Calculation - indicate compliance pat taken NA C405:4.2.1 BuildingAresMethod Complete required sompliance'foms - proposed wattage per builoting area ' does lot exceed maximum allowed Wattage per building area. identfy)ocations of bulking areas on plans Indicate all one-wa• down or reversible escalators are provided with a variable fregiencyregenerative drive Yes C405.4:2.2 Space -By -Space Method Complete required :omliancefoms-total proposedwatta e does not exceed maximum allowed wattage. identify locations of space types on dans, including renal display areas, lobby art & exhibit display anas, and ceiling heights as applicable Identify all cone -oiled and uncontrolled receptabtes on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, drplex devices, etc; fie C406.3 Red Emit lighting y power density To complywith addtional efficiency package option, demonstrate in conptianceforms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage viaBuilc'ln9 Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY Nn C405.5.2 Total connected exterior lighting power Include alt luminaires In fighting fixture schedule; indicate fixture types, tamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior aplications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exemlt exterior lighting is controlled independently from non-exempt eterlor lighting; include exception claimed for each 'fixture orgrotp of fixtures under exception category Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405 5.1 Extenorbuilcin B grounds lighting For building game fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) infixture schedule NA C405.5.2 Exteriorit htin 9 B power calculations Complete required:ompiiance form - proposed wattage for atelier lighting plu; base site allowed does not exceed maximum allowed ice,,, , •u .. �.r <C,. <., t` l hurl Motor- acid Electrtcal Permit Checklist P . LTG -CHK= 2015 Washington elate r ode Cornelia Forms for Co ere f I = dia s'Includi R3,Rd over 3 stories and an lel Ensce mm c a iiiniton Rsed August of R2,o u 6 St SY9 ng9 Project Title: McDonald's - Tukwila, WA Date 7/19/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electncalrequirements in the Washington State Energy Code, Commercial Provisions. Applicability (Yes no na) CodaSection Com nest Compliance information required inpermitdocuments Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelelectring unit electrical energy cansum tion p Group Indicate on electrical plans that each dwellingunit in p R-2 has a separate theatrical energy meter NA C405.8 Electric motor efficiency include all motor;, ncluding fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exce(tion as • lied NA C405-9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combiner! fixtures that indicates efficacy is not less than 35 lumens inmate Indicate rated watts per vim for elevator cab ventilation fans do not exceed 0.33 watts per cfin; Indicate automatic Controls that de -energize fighting and ventilation fans when elevator is stopped and unoocupled for a period of 15 minutes or more NA C405.9.2 Escalators and " moving walks Indicate escalators comply with ASME A17.1iCSA'B44; automatic controls Ire configured to reduce operational speed to the minimumPe rnitted when not in use NA C405.9.3 Re generative drive B Indicate all one-wa• down or reversible escalators are provided with a variable fregiencyregenerative drive 9A C405.10 Controlled receptacles Identify all cone -oiled and uncontrolled receptabtes on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, drplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable is occupant sensor or P by P programmable time•of day control If "no" is selected for any question, provide explanation; seven MULTI -SITE SOLUTIONS DESIGN LLC. Regional Office: 37704 Hills Tech Drive Farmington Hills, MI 48331 Telephone: 734-367-4445, Corporate Office: 4925 Forest Avenue Downers Grove, IL 60515 info@sevansolutlons.com www.sevansolutlons.com SAFETY - INTEGRITY - SUSTAINABILITY REVISIONS SEAL v• DICk s, 4wASit, ms = e O r✓ 0 %eOtsee ,ss/CNAL Gti 07/19/2017 EXPIRES 07054 '' SR SIGN •i'- 07/1 8/201 7 05/05/2018 J)ATF FXPIRATION DATF CERTIFICATION PREPARED FOR nitMcDonald's USA LLC These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific' site in conjunction with its issue date and are not suitable for use on a different site or at a later time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. PROJECT LOCATION McDonald's 15210 PACIFIC HWY W TUKWILA, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2017 End of Lighting, Motor & Transformer' Permit Documents Checklist SF: 1.00 CC JN: H:\17021.43 FN: E4.0 -ENERGY CODE_TUKWILLA,WA City of Tukwila BUILDING DIVISION SHEET TITLE ENERGY CODE RECEIVED CITY OF TUKWILA AN 0 9 2017 PERMIT C TER EPARATE MIT AND PROVAL WIRED SHEET MANAGEMENT PROJECT NO.: 046-0005 DATE ISSUED: 07/19/2017 DRAWN BY: SR REVIEWED BY: DD NATIONAL STORE # 11411 SHEET NUMBER E4.0 Electrical