Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL17-0033 - PLUM PLEX - CIRCUITS FOR SHOP EQUIPMENT
PLUM PLEX 4487 S 134T" PL BLDG A EXPIRED 07/29/17 EL1 7-0033 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 2613200084 Permit Number: 4487 S 134TH PL BLDG A Project Name: PLUM PLEX Issue Date: Permit Expires On: EL17-0033 1/30/2017 7/29/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: REALTY ASSOCIATES FUND X LP 1301 DOVE ST #860 , NEWPORT BEACH, WA, 92660 BRAD SALAZAR 4742 42 AVE SW #610 , SEATTLE, WA, 98116 A -PHASE ELECTRIC LLC 4742 42ND AVE SW #610 , SEATTLE, WA, 98116 PHASEEL911NJ Phone: (206) 769-9200 Phone: (206) 769-9200 Expiration Date: 10/13/2017 DESCRIPTION OF WORK: INSTALL CIRCUITS FOR SHOP EQUIPMENT Valuation of single family: $0.00 Valuation of mf/comm: $22,420.00 Type of Work: Fees Collected: $685.39 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature Date: I 9201 11 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign and obtain this development pe r it and -: , e e-onditions attached to this permit. Signature: /A Date: Print Na e:/� _ �►� ^ /?/20/7 hQ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKN 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. i Al- 6 Project No. Date Application Accepted: 1`tI Date Application Expires: " 1 � k 1 I^" 1 (For office use only). ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 1445S1 ;` 1(A Suite Number: Tenant Name: pk New Tenant: PROPERTY OWNER j Name: � � \ct.--).—c4. ✓ Address:4i t...‘ 2 t'" _At, e_ 61.0 Name: PhoneL� 6._,.1 �t ...9 Zt v. Emailda,v() b --c.) pcOvAe...c s+. net. Address: ,1� n� P6L1% 1� l`q Q�ax: City: State: Zip: CONTACT PERSON — person receiving all project communication j Name: � � \ct.--).—c4. ✓ Address:4i t...‘ 2 t'" _At, e_ 61.0 City1 i -- State: vi 4., ZI .g. ` t b C� PhoneL� 6._,.1 �t ...9 Zt v. Emailda,v() b --c.) pcOvAe...c s+. net. Floor: M Yes [1.. No ELECTRICAL CONTRACTOR INFORMATION m me: — (i►NaSe, elk... r i t✓. LLL 47 2. ilZ lie_ st9 -( i0 City i State: n f ,A �'T^1q y�f (f1 Ziff �j ,1� n� P6L1% 1� l`q Q�ax: ttLl��R&r...i.- i CV J Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 2-2 4Z6 Scope of Work (please provide detailed information): ,,LA, ,LAa, �eLry►1� T Will service be altered? DINYes ❑ No Adding more than 50 amps? (i Yes ❑ No Type of Use: Va. biq CrAkt Type of work: ❑ New ❑ Addition ❑ Service Change 0 Low Voltage 0 Generator ❑ Fire Alarm Property Served by: O Puget Sound Energy Seattle City Light H:WpplicationsWotn s -Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1.14.docx Revised: July 2013 bh O Remodel O Telecommunication c .. Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL, SERVICE ❑ • New single family dwellings N $152.85 (including an attached garage) O Garages, pools, spas and outbuildings $81.90 ea O Low voltage systems (alarm, furnace thermostat) $59.85 ea 0 0 0 0 RESIDENTIAL REMODEL AND SERVICE CHANGES Service change or alteration $81.90 (no added/altered circuits) Service change with added/altered circuits number of added circuits Circuits added/altered without service change (up to 5 circuits) Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea Meter/mast repair $68.25 '$81.90 $11.55 ea $54.60 Low voltage systems (alarm, furnace thermostat) $59.85 MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES1 1,4 O Temporary service (residential) $65.00 ❑ Temporary service (generator) ` $80.90 O Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 l1 , Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH (PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name:, L):�eJ` G Mailing Address: X11 `i 2 42 40 e - J -(DI c : 1 /2a t% Date. / t� Day Telephone206 74LI Cj 2,G79 City State H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-I-14.docx Revised: July 2013 bh Z p Page 2 of 2 DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $685.39 EL17-0033 Address: 4487 S 134TH PL BLDG A Apn: 2613200084 $685.39 Credit Card Fee $19.96 Credit Card Fee R000.369.908.00.00 1 0.00 $19.96 ELECTRICAL $639.84 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $511.87 PLAN CHECK FEE R000.345.832.00.00 0.00 $127.97 TECHNOLOGY FEE $25.59 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10374 R000.322.900.04.00 0.00 $25.59 $685.39 Date Paid: Wednesday, January 11, 2017 Paid By: DAVID SALAZAR Pay Method: CREDIT CARD 023813 Printed: Wednesday, January 11, 2017 10:38 AM 1 of 1 CRSYSTEMS 6/5/2017 City of Tukwila Department of Community Development BRAD SALAZAR 4742 42 AVE SW #610 SEATTLE, WA 98116 RE: Permit No. EL17-0033 PLUM PLEX 4487 S 134TH PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/29/2017. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/29/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: EL17-0033 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 EMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0033 PROJECT NAME: PLUM PLEX SITE ADDRESS: 4487 S 134TH PL X Original Plan Submittal Response to Correction Letter # DATE: 01/11/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 6 i\; Building Ilivision Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator I PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 01/12/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 02/09/17 ❑ Approved with Conditions ri ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 A -PHASE ELECTRIC LLC Home Espanol Contact Search L&I Page 1 of 2 A -Z Index Help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries A -PHASE ELECTRIC LLC Owner or tradesperson Principals SALAZAR, DAVID B, PARTNER/MEMBER SALAZAR, DAVID B, AGENT Doing business as A -PHASE ELECTRIC LLC WA UBI No. 602 942 046 4742 42ND AVE SW #610 SEATTLE, WA 98116 206-769-9200 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. PHASEEL911NJ Effective — expiration 08/11/2009-10/13/2017 Designated administrator SALAZAR, DAVID BRADLEY License type Master Electrician Bond Lexon Insurance Co. Bond account no. 9803476 Received by L&I 11/08/2010 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. SALAZDB972C7 $4,000.00 Effective date 11/08/2010 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 329,750-00 Doing business as A -PHASE ELECTRIC LLC Account is current. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602942046&LIC=PHASEEL911NJ&SAW= 1/19/2017 A -PHASE ELECTRIC LLC Estimated workers reported Quarter 3 of Year 2016 "1 to 3 Workers" - L&Iaccount representative T2 / LESLIE QUNELL (360)902-5631 - Email: BAKY235®Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602942046&LIC=PHASEEL911NJ&SAW= 1/19/2017 (E)300KVA UTILITY TRANSFORMER AIC = 17,200 (E)200A,480V,3PH METER AND METER BASE, TYPICAL OF SIX(6) NEW 2-1/2"C-(4)#250 KCM AL & (1)#4 AL GRD AIC =13,712 TMAIN-1 BMJ LMJ 17MJ VO IVI 4 �I DISC. 1 I 1 I I I I I 1 1 I I I 1 I—L---J--J---L----1---J-� - FL 600A _ I GRD I (E)POWER PANEL AND _ _ _ _ J (E)BUSS GUTTER CONDUIT/CONDUCTORS TO BE REMOVED I T rL—_'i L_ --J — (E)(2)3"C-(4)#350 KCM CU PANEL 4P 200A LEGEND: — — — — (E)EXISTING 1/,-z/,- ,4 EXISTING TO BE REMOVED (N)NEW PANEL LVB I I L 5°A .t, (E)CONDUIT AND CONDUCTORS TO REMAIN AIC = 2,964 AIC = 3,406 AIC = 9,716 AIC = 4,164 1 AIC =10,410 1 NEW 1"C-(3)#6 CU & (1)#10 CU GRD — EXISTING/NEW POWER RISER DIAGRAM NO SCALE 2P1-28 #8 2P1-29 o 2P1-24 25(1) 11'23 G G Q 4P-8 4P-7 2P1-20,22 2P1-16,18 2P1-11 l� 2P1-15 G 20 G G 22 G 18 16 60AS 40AF 2P1-23,25 11 0 �PANEL 0 KVA I LVA 1 75 KVA 1 1 TIS 100A J © 200A I =GRD I = GRD PANEL 2P1 2P1-19,21 21(1) 'I)19 G G PANEL 4P 1 C PANEL 2P1 (E)PANEL LVA (E)PANEL LVB 2P1-12,14 2P1-1 C NEW 2-1/2"C-(4)#250 KCM AL & (1)#1/0 AL GRD NEW 1-1/2"C-(3)#1 AL & (1)#6 AL GRD — (E)CONDUIT AND CONDUCTORS TO REMAIN (E)30KVA AND NEW 75KVA DRY -TYPE TRANSFORMER STACKED 30AS � 20AF 2P1-2 2P1-7 2P1-4 2P1-8 ca 12 G Gill 14 #10 ELECTRICAL FLOOR PLAN SCALE: 1/8"=1'-0" 30AS 20AF GENERAL NOTES: 1. ALL ELECTRICAL CONNECTIONS SHALL BE COORDINATED WITH OWNER EQUIPMENT BEING PROVIDED PRIOR TO ROUGH -IN. ELECTRICAL NOTES: CONTRACTOR SHALL PROVIDE CONNECTION TO TWELVE (12) 6 -LAMP, 32W, T8, FLUORESCENT TROFFER LIGHT FIXTURES. COORDINATE EXACT LOCATIONS OF FIXTURES IN FIELD WITH EQUIPMENT LAYOUT AND OWNER. THERE ARE EXISTING LIGHTING AND POWER CIRCUITS WITHIN THIS AREA CONNECTED TO EXISTING PANEL LVA AND LVB THAT SHALL REMAIN. No changes sh �F%: 7 TCie to the scope 7 of work without approval of Tukwila Build; �n Division. NOTE: Revisions will requiro a newl an and may include additional plan rev ew febeS�tta► FILE Copy Permit No, OW' ° Plan review ai ecct to errors and omission:1 Approval of coni € :a :-hints Coos not authorize the violation of any adopted code or ordinance. Receipt of approved Field 0. iy and conaitiop is acknowledged: By: � -ePt- Date: City of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC 1 �j JAN 17 2017 tl YT212' City of Tukwila BUILDING DIVISION C OTED REVIEW SUBMITTAL 6 CHECKQ /GLW SHEET 1 JOB NO.: 16-173 OF ENGINEERS, INC I so v \\\\\ \\\.\\\%, h , N v TU KWI LA, WA 98168 ELECTRICAL FLOOR PLAN/ POWER RISER DIAGRAM REVISIONS: sEr-..n ,.- '1. i {l':.i IJZ ice' 1.lil.. ❑ tcc.,i ficial (plumbing - [Gas Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 112017 PERMIT CENTER ,G-�.NL. y yG, 12 3e 0028060 �/STERA S;" SS�ONAL - - 0NAL " 12/21/16 C OTED REVIEW SUBMITTAL 6 CHECKQ /GLW SHEET 1 JOB NO.: 16-173 OF NEW SURFACE MOUNTING PANEL SCHEDULE 14,000 AIC NO. 4P LOCATION: TENANT SPACE SERVING: EQUIPMENT 480/277 VOLTS 3PHASE 4WIRE 200 AMPS WITH 200 MAIN BREAKER CKT LOAD DESCRIPTION KVA TRIP TRIPNo. KVA LOAD DESCRIPTION CKT No. AMP ir AMPS 1 (E)PANEL LVA VIA 24.40 50 lin 100 47.70 PANEL 2P1 VIA 2 3 k,r f � �N//��0029060:4: :I:: bISTEle '•ON AL E.- - " 11/ 21 / 16 GALE: • AS NOTED 75KVA XFMR 4 3 30KVA XFMR 4 3 SPACE 3 11SPACE 6 5 SPACE 6 3 SPACE 2.49 40 in 113 20 2.09 LIGHTS 8 7 CNC MACHINE 33.20 r„ IT 2 SPACE 10 9 1.08 RECEPTACLES 10 9 RECEPTACLES 1.08 20 20 12 1112 14 „ 11 SPARE 12 11 SPARE 20 14 13 SPACE 40 „ fl 1.56 20 iii SPARE 14 16 15 8.50 BREAKROOM PLUGS " 1.08 RECEPTACLES 16 11 18 18 17 1120 1.80 20 SPACE 18 17 .50 11 20 11 DUST COLLECTOR 22 20 19 19 SPACE „ REMARKS: . 11 1.08 OFFICE RECEPTACLES 18 20 21 23 ROUTER 1.80 BATHROOM LIGHTS 1.50 ,r 20 1122 MILL 24 25 SHOP VACUUM 1.80 23 HOT WATER HEATER „' '� Ill 2 " 26 27 1124 1.80 22 1111 26 25 OVEN 28 29 BAND SAW 1.80 11 1.20 MICROWAVE 30 25 27 2 31 SPARE 1128 20 SPARE 32 33 29 27 „ SPARE 1130 I ,� 20 35 31 SPARE 36 1132 20 37 SPACE 34 33 „ SPACE 38 11 11 32 36 35 39 SPACE 33 11 SPACE 42 38 37 34 REMARKS: . CONNECTED LOAD: 47.7 KVA 132 AMPS DEMAND LOAD: 48.8 KVA 136 AMPS 11 35 40 39 11 11• SPACE 42 , 41 SPACE REMARKS: . CONNECTED LOAD: 107.3 KVA 129 AMPS DEMAND LOAD: 116.9 KVA 141 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SERVICE LIGHTING RECEPTS TO 10KW RECEPTS OVER 10KW MOTORS (LARGEST) MOTORS KITCHEN EQUIP. WELDERS AIR CONDITIONING ELECTRIC HEAT MISCELLANEOUS PANEL 4P LOAD CALCULATIONS KVA LOAD FACTOR NEC REF. DEMAND LOAD 5.09 X 6.66 X X 33.20 X 49.12 X X - X X X 13.23 X TOTAL CONNECTED 107.3 KVA (129 AMPS) 1.25 1.00 0.50 1.25 1.00 1.00 1.00 1.00 1.00 1.00 220.19(A)(1) 220.44 220.44 430.24 430.24 220.56 630.11(8) 220.50 220.51 • 6.36 • 6.66 = 41.50 = 49.12 = 13.23 TOTAL DEMAND 116.9 KVA (141 AMPS) EXISTING - ALL CIRCUIT BREAKERS AND LOADS IDENTIFIED ARE EXISTING SURFACE MOUNTING PANEL SCHEDULE 10,000 AIC NO. LVB LOCATION: TENANT SPACE SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 60 AMPS WITH 50 MAIN BREAKER CKT N0. LOAD DESCRIPTION KVA TRIP `- TRIP KVA LOAD DESCRIPTION CKT AMPS ii AMPSN0. 1 SPACE 4.32 20 'i, 20 1.68 SPACE 2 3 f � �N//��0029060:4: :I:: bISTEle '•ON AL E.- - " 11/ 21 / 16 GALE: • AS NOTED " 2 2 2.91 BELT SANDER 4 3 SPACE 3 11SPACE SPACE 6 5 SPACE 2.49 20 king „ 20 4.58 SPARE 8 7 RECEPTACLES 1.08 20 IT 2 „ 10 1.56 1.08 RECEPTACLES 10 9 RECEPTACLES 1.08 20 20 1.68 DUST COLLECTOR 14 „ 11 SPARE 12 11 SPARE 20 1.68 DUST COLLECTOR 40 „ SMALL CNC 1.56 20 iii SPARE 14 13 ROOF TOP UNIT 8.50 BREAKROOM PLUGS " 1.08 RECEPTACLES 16 15 18 3 1120 1.80 20 SPACE 18 17 .50 COMPUTER 20 11 DUST COLLECTOR 22 SPACE 20 19 SPACE „ REMARKS: . CONNECTED LOAD: 12.8 KVA 36 AMPS DEMAND LOAD: 14.9 KVA 42 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SERVICE LIGHTING RECEPTS TO 10KW RECEPTS OVER 10KW MOTORS (LARGEST) MOTORS KITCHEN EQUIP. WELDERS AIR CONDITIONING ELECTRIC HEAT MISCELLANEOUS PANEL LVB LOAD CALCULATIONS KVA LOAD FACTOR NEC REF. DEMAND LOAD 4.32 8.50 1.25 1.00 0.50 1.25 1.00 1.00 1.00 1.00 1.00 1.00 220.19(A)(1) 220.44 220.44 430.24 430.24 220.56 630.11(B) 220.50 220.51 = 4.32 = 10.63 TOTAL CONNECTED 12.8 KVA TOTAL DEMAND 14.9 KVA (36 AMPS) (42 AMPS) NEW SURFACE MOUNTING PANEL SCHEDULE 10,000 AIC NO.2P1 LOCATION: TENANT SPACE SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 200 AMPS WITH 200 MAIN BREAKER CKT N0. LOAD DESCRIPTION I(�/q TRIP ��� TRIP KVA LOAD DESCRIPTION CKT N0. AMPS 1 AMPS 1 TABLE SAW 4.32 20 'i, 20 1.68 DUST COLLECTOR 2 3 f � �N//��0029060:4: :I:: bISTEle '•ON AL E.- - " 11/ 21 / 16 GALE: • AS NOTED k1111 2 2 2.91 BELT SANDER 454 OF - - 5 3 1; 3 7 TABLE SAW 2.49 20 king 30 4.58 COMPRESSOR 8 9 20 .18 2 IT 2 10 1.56 PANEL SAW 12 11 COMPRESSOR 4.58 30 di 20 1.68 DUST COLLECTOR 14 132 11 SPARE 12 1.68 DUST COLLECTOR 16 15 SMALL CNC 1.56 20 iii 11 17 BREAKROOM PLUGS 14 .50 COMPUTER 18 19 ROUTER 1.80 20 ;; OFFICE RECEPTACLES 16 .50 COMPUTER 20 1.68 DUST COLLECTOR 22 21 SHOP VACUUM 1.00 „ 1.08 OFFICE RECEPTACLES 18 20 23 ROUTER 1.80 BATHROOM LIGHTS 1.50 ,r 20 2.70 MILL 24 25 SHOP VACUUM 1.80 21 HOT WATER HEATER „' '� Ill 2 " 26 27 DRILL PRESS 1.80 22 1111 40 6.03 OVEN 28 29 BAND SAW 1.80 1.20 MICROWAVE 30 25 SPARE 2 31 SPARE „ 20 SPARE 32 33 SPARE 27 „ SPARE 34 I ,� 20 35 SPARE SPARE 36 20 20 37 SPACE 31 „ SPACE 38 11 32 SPACE 40 39 SPACE 33 11 SPACE 42 41 SPACE 34 REMARKS: . CONNECTED LOAD: 47.7 KVA 132 AMPS DEMAND LOAD: 48.8 KVA 136 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SERVICE LIGHTING RECEPTS TO 10KW RECEPTS OVER 10KW MOTORS (LARGEST) MOTORS KITCHEN EQUIP. WELDERS AIR CONDITIONING ELECTRIC HEAT MISCELLANEOUS PANEL 2P2 LOAD CALCULATIONS KVA LOAD FACTOR NEC REF. DEMAND LOAD 4.58 36.04 7.03 TOTAL CONNECTED 47.7 KVA 1.25 1.00 0.50 1.25 1.00 1.00 1.00 1.00 1.00 1.00 220.19(A)(1) 220.44 220.44 430.24 430.24 220.56 630.11(B) 220.50 220.51 = 5.73 = 36.04 • 7.03 TOTAL DEMAND 48.8 KVA (132 AMPS) (136 AMPS) EXISTING - ALL CIRCUIT BREAKERS AND LOADS IDENTIFIED ARE EXISTING SURFACE MOUNTING PANEL SCHEDULE 10,000 AIC NO. LVA LOCATION: TENANT SPACE SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 100 AMPS WITH 100 MAIN BREAKER CKT N0. LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT N0. AMPS 11 AMPS a\UU\\UU\\UU SPARE 20 20 12.80 (E)PANEL LVB 4 3 f � �N//��0029060:4: :I:: bISTEle '•ON AL E.- - " 11/ 21 / 16 GALE: • AS NOTED DATE: 12-21-16 SHEET E1.1 11 CKELH/GLD BY: SW JOB NO.: 16-173 OF - - 5 1; 3 6 7 20 .18 ROOF TOP GFI 8 9 11 SPARE 10 11 11 SPARE 12 13 11 BREAKROOM PLUGS 14 15 111.50 1.08 OFFICE RECEPTACLES 16 17 SPARE „ 1.08 OFFICE RECEPTACLES 18 19 BATHROOM LIGHTS 1.50 „ 1.50 SERVER RECEPTACLES 20 21 HOT WATER HEATER .5011 " 1.50 SERVER RECEPTACLES 22 23 OFFICE LIGHTS 1.50 1.20 MICROWAVE 24 25 SPARE „ SPARE 26 27 11 28 29 11 30 31 1, 32 33 11 34 35 11 36 37 11 38 39 11 40 ► 41 SPARE 20 11 SPARE 42 20 REMARKS: . CONNECTED LOAD: 24.4 KVA 68 AMPS DEMAND LOAD: 27.2 KVA 76 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SERVICE LIGHTING RECEPTS TO 10KW RECEPTS OVER 10KW MOTORS (LARGEST) MOTORS KITCHEN EQUIP. WELDERS AIR CONDITIONING ELECTRIC HEAT MISCELLANEOUS PANEL LVA LOAD CALCULATIONS KVA LOAD FACTOR NEC REF. DEMAND LOAD 3.00 X 6.66 X X 8.50 X X X X X X 6.20 X TOTAL CONNECTED 24.4 KVA 1.25 1.00 0.50 1.25 1.00 1.00 1.00 1.00 1.00 1.00 220.19(A)(1) 220.44 220.44 430.24 430.24 220.56 630.11(B) 220.50 220.51 3.75 6.66 10.63 = 6.20 TOTAL DEMAND 27.2 KVA (68 AMPS) (76 AMPS) 001 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC JAN 17 201.1 "-City of Tukwila BUILDING DIVISION EVIEW SUBMITTAL CROSS ENGINEERS, INC 6509 6th Avenue Phone: (253) 759-0118 Tacoma, WA 98406 Job Number: 16-173 info@crossengineers.com a\UU\\UU\\UU PLUM PLEX 4487 S. 134TH PL TUKWILA, WA 98168 ELECTRICAL SCHEDULES REVISIONS: RECEIVED CITY OF TUKWILA JAN 1 1 2017 PERMIT CENTER f � �N//��0029060:4: :I:: bISTEle '•ON AL E.- - " 11/ 21 / 16 GALE: • AS NOTED DATE: 12-21-16 SHEET E1.1 RAWN BY: JAE CKELH/GLD BY: SW JOB NO.: 16-173 OF - -