Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL17-0132 - RUBY THAI KITCHEN - REMODEL
RUBY THAI KITCHEN 2600 SOUTHCENTER MALL FC -15 ELI 7-0132 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 9202470010 2600 SOUTHCENTER MALL FC15 Project Name: RUBY THAI KITCHEN Permit Number: EL17-0132 Issue Date: 5/1/2017 Permit Expires On: 10/28/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 DANA MERRITT 2915 184 AVE E , LAKE TAPPS, WA, 98391 INFINITY CONSULTING INC 2915 184 AVE E , LAKE TAPPS, WA, 98391 INFINCI998PP ,,, Phone: (253) 405-0666 Phone: (253). 862-7585 Expiration Date: 10/19/2017 DESCRIPTION OF WORK: RESTAURANT REMODEL: RELOCATE SUPANEL, REARRANGE LIGHTING, OUTLETS AND EQUIPMENT Valuation of single family: $0.00 Valuation of mf/comm: $20,000.00 Type of Work: TENANT IMP Fees Collected: $612.89 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws g construction or the pe`r ormance of work. I am authorized to sign and obtain this develo• permit and .gree to the conditions attac ed to this per it. Signature: Print Name: Z)/974., Date: 551/ / / 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKT A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.aov Electrical Pe, mit No. P [I- 0 /5` Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION A. Site Address: OU SC C -t& Ad/King Co Assessor's Tax No.: 210A Suite NumbercC / < Floor: 3 Tenant Name: i (7i1 y 7� % j '7"-C /-��, V New Tenant: Yes ❑.. No PROPERTY OWNER - Name: Name: //t%.6F7A--c_-...L.;)5 /til lrQ' i Address: Email: p:..41612, 1 , . wxi r1i /7-y City: State: Zip: CONTACT PERSON - person receiving all project communication Name: Address: Z9/5 .k27) 4ye c City: C/C 7-APAS State: et, %i Zip: �� Phone:7iS 4/0 S -0C ax: 2-S 7g2L ,E'g 2- Email: p:..41612, 1 , . wxi r1i /7-y ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: • Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; acvS&c 7,4, G. us Valuation of Project (contractor's bid price): $ (9,D) C.Y6IC7 Scope of Work (please provide detailed information): ,%2� c7.Z142.) r1,77' it) & x/61/rt i o/eG/Q)?, vj> w z� 9vv 40 CC.5 ) i Will service be altered? it Yes No Type of Use: T P 1' •Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applications-Handouts \Permit Applications\Word\Electrical Permit Application Revised 1-1-2017.docx Revised: January 2017 bh Adding more than 50 amps? ❑ Yes No ❑ Service Change Remodel ❑ Tenant Improvement 0 Fire Alarm ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea O Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea PERMIT APPLICATION NOTES - Value of Construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL •C I RACTOR: Signature( Date: Print Name 2.). ,-1,09 ) Mailing Address: �9 V - Day Telephone: 9-534 W:\Permit Center\Applications-Handouts\Permit Applications \Word\Electrical Permit Application Revised I-1-2017.docx Revised: January 2017 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK 1 ACCOUNT I QUANTITY I PAID $612.89 EL17-0132 Address: Apn: $612.89 Credit Card Fee $17.85 Credit Card Fee 1 R000.369.908.00.00 0.00 $17.85 ELECTRICAL $572.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $457.72 PLAN CHECK FEE R000.345.832.00.00 0.00 $114.43 TECHNOLOGY FEE $22.89 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10855 R000.322.900.04.00 0.00 $22.89 $612.89 Date Paid: Tuesday, February 21, 2017 Paid By: INFINITY CONSULTING INC Pay Method: CREDIT CARD 162267 Printed: Tuesday, February 21, 2017 1:27 PM 1 of 1 C! SYSTEMS 2 - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION —0131. 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-36 Project: got ,I�UE�� t,w Type of inspection: 64-1_ Address: 00 A , fr14 Date Called: Special Instructions: t / Date Wanted: a.m. Requester: ^ rAr ►4�\`�•\►!sT Phone No: /Or 0666 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: eakecxib4- ti,e1DC OK Date: os—/0,4 j 0y 17 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION RECORD Retain a copy with permit at/'01 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f��� l I �� Type of Inspection: /�h1� ,�tj Address: 7-6 do /Pik/ Date Called: Special Instructions: Ftp! 9. f f}o K/ri m Date Wanted: a. 3 p.m. /� Requester: Phone No: 2-5 *Co 0 ElApproved per applicable codes. J Corrections required prior to approval. COMMENTS: - L. -Pry .,' eQuiet-tedr tPATieL.3 w r a '.k. citkL Y t r- Irl l ib7 L4 s l F - 4C coAJ C tJ$6 Intl SE i'(k - &—I 1 AP Ul 9 kip Keuri ,1Wb I 41LINAPp i P id r i ci etre K. &kr t R , e)vIti6p Date: 3/t7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 outhcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0132 DATE: 02/21/17 PROJECT NAME: RUBY THAI KITCHEN SITE ADDRESS: 2600 SOUTHCENTER MALL - FC -15 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/23/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/23/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: [Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 INFINITY CONSULTING INC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I A -Z Index Help Page 1 of 2 My L&l Workplace Rights Trades & Licensing INFINITY CONSULTING INC Owner or tradesperson Principals MERRITT, DANA V, PRESIDENT MERRITT, DANA V, AGENT Doing business as INFINITY CONSULTING INC WA UBI No. 602 151 041 2915 184TH AVE E LAKE TAPPS, WA 98391 253-862-7585 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. INFINCI998PP Effective — expiration 10/17/2001— 10/19/2017 Designated administrator .......................................................................... HORNER, MARK R License type Master Electrician Bond ........._...... Lexon Ins Co Bond account no. 9810297 Received by L&I 10/06/2011 Bond history Savings No savings accounts during the previous 6 year period. License Violations ..................................................... No license violations during the previous 6 year period. Active. Meets current requirements. License no. HORNEMR965R1 $4,000.00 Effective date 09/28/2011 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602151041 &LIC=INFINCI998PP&SA W= 5/1/2017 INFINITY CONSULTING INC 986,696-01 ................................. Doing business as INFINITY CONSULTING INC Estimated workers reported Quarter 4 of Year 2016 "4 to 6 Workers" L&I account representative T4 / TERRI MADISON (360)902-4654 - Email: KIRT235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602151041 &LIC=INFINCI998PP&SAW= 5/1/2017 EXIST. A-33,35 AA-2 B-10 B-11 B-5 ii.//7/ r�:. .�i��oii..�iiriii�iiifi_i�/ % A-39 VIA T/C TIE TO A-14 VIA T/C B-2 A-25,27 TIE TO A-11,13,15 A-14 VIA T/C A-3. ELECTRICAL POWER PLAN SCALE: 1' = 1'-0" [EXIST. ,EXIST. EF -1 ON I i ~---- -" A-22,24,26 ! ROOF I THRU EXIST. HOOD PANEL 0 EXIST. EXIST. A-38 r • WP GFI [EXIST. Tri. 1 SF -1 ON LROOF . EXIST. A-28,30,32 THRU EXIST. HOOD PANEL SYM BO LS GENERAL NOTES: KEY NOTES: RECESSED NIGHT LT (N/L) DUPLEX RECEPTACLE WITH 120 V, 20 AMPERE RATING. HEIGHT 16" TO BOTTOM UNLESS NOTED OTHERWISE. (TYP.) GFI DUPLEX W/GRND F. INTERRUPTER AT COUNTER SHALL BE 42" AFF TO BOTTOM UNLESS NOTED OTHERWISE DUPLEX W/ISOL. GRND CONDUCTOR ATA HEIGHT TO THE BOTTOM AS NOTED. 0 JUNCTION BOX 1h DISCONNECT SWITCH TELEPHONE JACK ELECTRICAL POWER PANEL TWO WAY SWITCH WATER HEATER MANUAL PULL STATION - 270 -SPO 42" A.F.F. ©1 HORN/STROBE-792-7A-006 80" A.F.F. HEAT DETECTOR -281B O REFER TO THE CODED NOTE NUMBER. CONCEALED IN WALL, CEILING OR UNDER CONDUIT RUN CONSISTING OF: Z - GROUND CONDUCTOR III - SMALL LINES INDICATE POWER NON GROUNDED CONDUCTORS. I - BIG LINE INDICATES NEUTRAL CONDUCTOR "C" TYPE UNDER COUNTER COVE LIGHT A-40 VIA T/C "C" TYPE SOFFIT LEDGE COVE LIGHT TIE TO A-14 VIA T/C "C" TYPE UNDER COUNTER COVE LIGHT ELECTRICAL LIGHTING PLAN SCALE: 1" = 1'-0" 1 1 1 1 1 1 1 1 J REVISIONS No changes sh^II h' rna..de to the scope of work witho!.:t prior approval of T ul«'lila Building Division. NOTE: Revisions will tcquiro a new plan submittal and may include additional plan review fees t - OR. Cg Mechanical 0 Elec:ncal LI ('iumbing 0 s Piping Ci I r t:vi is D `,fISION 1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. 2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY AND USE EXISTING POWER SUPPLY, EQUIPMENT, POWER PANELS, XFRMR AND FEEDERS TO COMPLY WITH PANEL SCHEDULES. REFER TO KEY NOTE #19. 4. CONTRACTOR VERIFY EXISTING AND FURNISH AND INSTALL NEW WIRING AS SHOWN ON THE ELEC. PLANS, PANEL SCHEDULES AND RISER DIAGRAM. ALL EXISTING AND NEW WIRING SHALL BE IN COMPLIANCE WITH N.E.C. TABLE 310-16. 5. PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE AND LOW VOLTAGE SYSTEM. 6. INTERIOR TELEPHONE WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALLTELEPHONE JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH THE TENANT. 7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. 8. FURNISH ATYPE WRITTEN CIRCUIT DIRECTORY CARD FOR ALL PANELS, LISTING ALL USED AND SPARE CIRCUITS. 9. CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL REQUIREMENTS AND LOCATIONS OF ALL HVAC EQUIPMENT PRIOR TO INSTALLATION. 10. ALL OUTLET AND SWITCHES COVER PLATES SHALL BE STAINLESS STEEL. ALL OUTLET BOXES SHALL BE MOUNTED FLUSH IN WALLS AND SHALL BE MOUNTED AT HEIGHT AS INDICATED ON THE EQUIP. PLAN. COORDINATE ALL LOCATIONS WITH EQUIPMENT INSTALLATION AND ARCHITECTURAL DRAWINGS. 11. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS NOTED OTHERWISE. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 14. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS. 15. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. AND LANDLORD'S MANAGER. 16. CONTRACTOR, UPON COMPLETION OF HIS WORK , SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL CERTIFICATIONS. 17. CONTRACTOR SHALL COMPLY WITH THE LANDLORD'S DESIGN CRITERIA FOR ELECTRICAL AND FIRE ALARM SYSTEMS. MAKE NECESSARY CONNECTIONS BETWEEN TENANT'S FIRE DETECTING DEVICES AND THE LAND LORD'S FIRE ALARM STATION. 18. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR TO THE COLUMN LINES. 19. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16, 2008. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 100 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE INSULATION SHALL BE THHN OR THWN. 20. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL STEEL OR EMT COND. AND IN COMPLIANCE WITH THE N.E.C. AND LAND LORD'S DESIGN CRITERIA. 21. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BETWEEN LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEX. CONDUIT IS NOTMOREMAN 6FEET. 22. MC CABLES SHALL NOT BE USED FOR HOME RUN CIRCUITS AND FOR THE -- WIRING WITHIN PARTITION OR DEMISING WALL CONSTRUCTION. ALL IN -WALL CONCEALED WIRING MUST BE RUN IN RIGID CONDUITS. 23. THE GROUND ON THE SEPARATELY DERIVED SERVICE SHALL BE BONDED TO THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPING WITH CAD WELD CONNECTION. REFER TO KEY NOTE #22. 1 24. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED THERMAL MAGNETIC TYPE - TWO (2) AND THREE (3) POLE MOLDED CASE CIRCUIT BREAKERS SHALL`BE WITH COMMON TRIP. 25. UNLESS NOTED OTHERWISE, WIRE AND CABLE SIZES SHALL BE IN COMPLIANCE WITH BRANCH CIRCUIT FEEDER CIRCUIT SCHEDULE, RISER DIAGRAM AND THE- N.E.C. TABLE 310-16. 26. ROMAX, TYPE AC AND NM CABLES SHALL NOT BE PERMITTEL3:="" 27. CONDUCTORS SHALL BE COPPER PER LLCRITERIA. 28. ALL BREAKERS USED FOR LIGHTINGCIRCUITS SHALL BE CONTINUOUS DUTY LIGHT SWITCHING RATING:= - 0 PROVIDE LOCK TAB AT CIRCUITS WHICH FEED POWER TO EXIT, NIGHT AND EMERG. LIGHTS IN "ON" POSITION. NIGHT LIGHTS SHALL BE CONTROLLED BY A KEYED SWITCH AND ALL EXIT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL SWITCHES. • CONTRACTOR MUST COORDINATE AND SUBMIT CUT SHEETS OF ALL NEW LIGHT FIXTURES AND MUST GET APPROVAL FROM THE OWNER OF ALL UGHT FIXTURE MODEL NUMBERS BEFORE PURCHASING ANY NEW LIGHT FIXTURES. 0 CONTRACTOR SHALL PROVIDE A NEW TIME CLOCK (T/C). INSTALL JUNCTION BOXES, RECESSED OUTLETS AND SWITCHES FOR THE MENU BOARD AND STORE SIGN CIRCUITS AS REQUIRED. 0 ROUTE ALL LIGHTING/SIGN CIRCUITS THROUGH A WATT STOPPER 8 RELAY PEANUT PANEL LP8S-8-G-115 AND PRQVIDE AS -100-W SWITCHES FOR ALL LIGHTING SWITCHES. (FOR TIME OF DAY CONTROL AND LOCAL OVERRIDE ) • VERIFY EXISTING OR INSTALL NEW SWITCH LEG AS SHOWN. EACH SWITCH DESIGNATION WHICH CONTROL THE SPECIFIC LIGHT IS MARKED ON THE PLAN. 0 INSTALL UNDER COUNTER AND SOFFIT COVED LED LIGHT PER LIGHTING SCHEDULE, LOW VOLTAGE POWER SUPPLY SHALL BE LOCATED WITHIN AN ACCESSIBLE LOCATION. 0 PROVIDE A MINIMUM 1/2" CONDUIT W/WIRE FROM TELEPHONE OUTLET BACK TO TELEPHONE BOARD. THIS IS TYPICAL FOR ALL TELEPHONE OUTLETS. 0 CONTRACTOR SHALL COORDINATE WITH LANDLORD AND INSTALL NEW TELEPHONE BOARD, AS REQUIRED. EXTEND EXISTING TELEPHONE CONDUIT AND CABLE TO TENANT'S TEL. BD "TTB". COORDINATE ALL TELEPHONE REQUIREMENTS WITH TENANT. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA/TEL OUTLETS. THE TELEPHONE SYSTEM SHALL BE COMPLETE AND FUNCTIONAL. 0 ALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS. ALL KITCHEN AREA OUTLETS SHALL BE WITH GFI TO COMPLY WITH N.E.C. STD. #210.8(B)(2).TOECONOMIZE THE COST THE CONTRACTOR SHALL INSTALL FIRST OUTLET AT WHICH THE HOME RUN IS CONNECTED, WITH GFI AND ALL OTHER DOWN STREAM OUTLET NORMAL WITHOUT GFI. 10 THE CONTRACTOR SHALL COORDINATE WITH LANDLORD AND DETERMINE WHAT KIND OF LIFE SAFETY AND FIRE ALARM DEVICES ARE REQUIRED BEFORE BIDDING FOR THE PROJECT. USE EXISTING OR FURNISH AND INSTALL NEW FA DEVICES AS REQUIRED, IN COMPLIANCE WITH THE POWER PLAN AND ANSUL WIRING DIAGRAM, LANDLORD'S CRITERIA, NFPA AND LATEST APPLICABLE CODE REQUIREMENTS. TIE TENANT'S FA SYSTEM TO THE BASE BUILDING FA SYSTEM AS REQUIRED. 11 PROVIDE SHUNT TRIP CIRCUIT BREAKER TO ALL EQUIPMENT UNDER THE HOOD. INTERLOCK SHUNT TRIP W/ HOOD ANSUL SYSTEM. 12. THE CONTRACTOR SHALL COORDINATE WITH THE KITCHEN APPLIANCES CONTRACTOR AND PROVIDE ALL HARDWARE AND CONNECTIONS AS REQUIRED. THIS IS TYPICAL. 13 FURNISH AND INSTALL POWER CIRCUITS AND JUNCTION BOXES FOR STEAM TABLES (#3 .1), SOUP/NOODLE WARMER (#4), SNEEZE GUARD LIGHTS(#5), AND COMBI OVEN (#20). DETERMINE EXACT LOCATION OF JUNCTION BOXES AT SITE WITH TENANT. MAKE ALL CONNECTIONS AS REQUIRED. 14 , CONTRACTOR SHALL COORDINATE WITH KITCHEN EQUIP. CONTRACTOR AND ROUTE 208V,10, CIRCUIT WITH NEUTRAL AND GRND CONDUCTORS FOR ICE MACHINE. FURNISH JB OR SPECIAL OUTLET AS REQ'D AND MAKE NECESSARY CONNECTIONS OF REMOTE CONDENSER. 15 CONTRACTOR SHALL COORDINATE WITH KITCHEN AND REFRIGERATION CONTRACTORS AND DETERMINE EXACT RATING OF ALL EQUIPMENT AND TYPE OF REQUIRED POWER LEAD CONNECTIONS AT EACH EQUIP. MUST ADJUST SIZE OF BREAKERS IF OR AS REQUIRED. THIS IS TYPICAL. 16 VERIFY EXISTING POWER SUPPLY TO EXISTING HOOD AND ANSUL PANELS. VERIFY EXISTING POWER SUPPLY AND EXISTING DISC. SWITCHES FOR EXISTING EXHAUST AND SUPPLY FANS. VERIFY EXISTING Wp, GFI OUTLET ON ROOF NEAR FANS. MAKE ALL CONNECTIONS AS REQUIRED. 17 ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH WHITE SILICONE. THIS IS TYPICAL. 0 PROVIDE KEY -LOCK TABS AT THESE CIRCUITS. ROUTE CASH REGISTER CIRCUITS WITH AN ISOLATED GROUND, CONDUCTORS. 0 REUSE EXISTING 200 AMP, 120/208V, 3PH POWER SUPPLY IN WITH THE RISER DIAGRAM, PANEL SCHEDULES, AND AS DESCRIBED BELOW: a) VERIFY THAT ALL EXISTING EQUIPMENT AT THE LANDLORD'S METER CENTER INCLUDING DISC. SWITCH, METER, FEEDERS AND CONDUITS ARE IN COMPLIANCE • WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. IF NOT UPGRADE THEM PER •• RISER DIAGRAM. b) RELOCATE AND REUSE EXISTING PANEL "A" AND FURNISH AND INSTALL NEW SUBPANEL "B" IN COMPLIANCE WITH THE RISER DIAGRAM AND PANEL SCHEDULES. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED TYPE BREAKERS. REFER TO FOOT NOTES AT PANEL SCHEDULES. c) THE GROUNDING SYSTEM SHALL BE INSTALLED TO COMPLY WITH N.E.C. STD #250 REQUIREMENTS. ALL EQUIPMENT SHALL BE GROUNDED IN COMP -LANCE WITH N.E.C. • STD. #250, 2008. AND UL REQUIREMENTS. is LE COPY Permit No.tkk 0 iV--a Plan , rvi. : is subject to errors and omissions. Approval of cons. :::u n cQcLimont: does not auihoiize the violation of any adopted code or ordinance. Receipt of approved Fi: •�;,�y and conditions is acknowledged: Adi► Date City of Tukwila BUILDING DIVISION BRANCH CIRCUIT FEEDERSCHEDULE AMP/POLE CONDUCT. 15A/1P OR 15A/2P (2) #12 GND. CONDUCT. #12 CON. 20A/1P OR 20A/2P (2) #12 #12 15A/3P OR 20A/3P (3) #12 25A/1P OR 25A/2P (2) #10 30A/1P OR 30A/2P (2) #10 25A/3P OR 30A/3P (3) #10 35A/1P OR 35A/2P (2) #8 40A/1P OR 40A/2P (2)#8 35A/3P OR 40A/3P (3) #8 45A/1P OR 45A/2P (2) #6 50A/1P OR 50A/2P (2) #6 45A/3P OR 50A/3P 60A/1P OR 60A/2P 60A/3P 70A/3P OR 80A/3P (3) #6 (2) #4 (3) #4 (3) #4 #12 #10 #10 #10 #10 #10 #10 #10 #10 #10 #8 #8 #8 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 90A/3P 100A/3P OR 110A/3P 125A/3P (3) #3 #8 1 1/4" (3) #2 #6 1 1/2" (3) #1 #6 /2" - PROVIDE BRANCH CIRCUIT FEEDERS AS NOTED ABOVE UNLESS NOTED OT ERWI E EL7O 13 LIGHTING FIXTURE SCHEDULE 0000 O DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: 1=3 Minn WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA E. 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 IEWEC F tf COMPLIANCE ITH NFI'A70 E TYPE SYMBOL DESCRIPTION QTY. MANUFAC. CATALOG LAMP MTG. VOLT REMARKS LAMPS/ FIXT. BALLASTS BALLAST FIXT. TOTAL WATT 11 C E FLEXIBLE UNE VOLTAGE LED UNEAR STRIP RECESSED DOWN LIGHT 70 FT. 29 INFINA LITHONIA DL -AC -FLEX -30 6G1MW LED LED 3000K WARM WHITE 10.8 WATT LED (620 LUMENS) COVED RECESSED 120 120 PROVIDE ALL REQ'D. HARDWARE 10%-100% DIMMING 1 G 0 RECESSED DOWN LIGHT 31 JUNO ICI LEDG4-3K- 1 14W -WH 14 WATT LED 1 4"r+F�ull IN VI 8444 SEAL REGISTERED ARCHITECT tmaAVI. Kr WA S7AtE OF w,iTT sHIHGTOH ECT. POWER & LI HTING PLANS _ AND NOTES SHEET NUMBER 10.8 RECEIVED CITY OF TUKWILA 14 NOTES: 821 ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. INSTALLATION OF UGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. FEB 21 201E 1 . O 84PER3 ALL LAMPS IN FLUORESCENT LIGHT FIXTURES TO BESYLVANIA UNLESS NOTED OTHERWISE. MIT CENTER PROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA. EXIST: PANEL "A" (3) MCB: 150 AMP MLO: N/A A.I.C.: 22,000 AMP VOLTS: 120/208 V PHASE: 3, S/N WIRE: 4 MTD: RECESS WITH ISO. & EQUIPMENT GROUND BUSSES BLDG: RUBY THAI KITCHEN SPACE TOTAL 13.45 15.25 13.70 8.83 6.58 8.35 TOTAL OA DESCRIPTION OF LOAD BRKR KVA PH LOAD CIR NO PHASE CIR NO KVA PH LOAD BRKR DESCRIPTION OF LOAD M OA OB OC P AMP AMP P OA OB OC A B C R CASH REGEISTER (IG) (#2) 20 1 0.30 1 1 a 2 2 1.12 1 1 20 3 DOOR REACH -IN COOLER (#47) K J, CASH REGEISTER (IG) (#2) 4, 4, 0.90 0.30 3 3 a m 4 4 0.98 SPACE K SOUP/NOODLE WARMER (#4A) 25 3 3.00 5 a 6 3.34 3 60 SUBPANEL "B" T v " SODA DISPENSER (#7) 3.00 7 U 8 3.55 RECEPT. R R RECEPT. N./ Ni v 3.00 9 ■ 10 3.38 RECEPT. K WORKTOP FREEZER (#41) STEAM TABLE (#3) 50 3 11 4.00 11 12 a 12 .s, \,. 0.75 1 20 LIGHTS (G), (E) & COVE (C) (T/C) L „ ,, 0.47 4.00 a 13 a 14 1.00 SPACE 4, 4,, Jj, (E), U.C. (C) & S.G. (#5) (T/C) a, 15 4.00 15 a 16 SPACE COMBI OVEN (#20) 35 3 17 3.70 17 18 a 18 0.96 2 20 ICE MACHINE (#29) K 3.70 19 a 20 0.96 �, y .,, .., v v v ,, 3.70 21 0 22 1.00 3 20 EXIST. EF -1 M . RESERVED FOR SHUNT TRIP 23 a 24 1.00 K STEAM TABLE (#3) 20 2 1.50 25 a 26 1.00 4, J,, 4, N, 1.50 27 0 28 1.00 3 20 EXIST. SF -1 SPACE 29 0 30 1.00 I TIME CLOCK /SHUNT TRIP RELAY 20 1 0.20 31 32 1.00 .., v W EXIST. WATER HEATER (#40) 30 2 2.25 33 a 34 SPACE 4 v N(, 4, 2.25 35 a 36 0.10 1 20 EXIST: HOOD & ANSUL PANELS L LIGHTS MENU BOARDS (#10) (T/C) 20 1 0.75 37 38 020 EXIST. ROOF RECEPT. R MENU BOARDS (#10) (T/C) 0.50 39 0 40 1.20 LIGHTS SIGN (T/C) L v v MENU BOARDS (#10) (T/C) y y, 0.75 41 a 42 120 v , v SIGN (T/C) v TOTAL 13.45 15.25 13.70 8.83 6.58 8.35 TOTAL OA LEGEND L LIGHTING R RECEPTACLE K KITCHEN EQUIPMENT I MISCELLANEOUS M MOTOR/FAN T TRANSFORMER/PANEL/ATS W WATER HEATER TOTAL 13.45 15.25 13.70 8.83 6.58 8.35 TOTAL OA OB OC KVA PH LOAD 22.28 21.83 22.05 TOTAL CONNECTED KVA 186 182 184 TOTAL CONNECTED AMPS 1) (2) 3) 4) (5) (6) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION. ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. PROVIDE THIS BREAKER WITH SHUNT TRIP DEVICE. ROUTE THESE LIGHT CIRCUITS THROUGH T/C. USE EXISTING BREAKERS AND WIRING FOR EXISTING LOADS. NO CHANGE IS REQUIRED. REFER TO PANEL"B" SCHEDULE FOR THIS LOAD DETAILS. (5) 00 ELECTRICAL -1 ROOM 0® EXIST. 443/0, CU, 146, CU, GRND, IN2"C. EXIST. 75 KVA 480V -120/208V XFRMR EXIST. C> TO EXIST. METER i 75 j AND DISC. SW. AT L _KVA J EXIST. LANDLOARD 1 iJ SWITCHBOARD-+-------� r TENANT SPACE L IT/CI RELOC. EXIST. PANEL nATT 200 AMP MCB 120/208V --J EXTEND EXIST. 4-#3/0, CU, 146, CU, GRND, IN 2" C. TO NEW PANEL LOCATION 7 DAY, 24 HRS TIME CLOCK T/C NEW SUBPANEL 0 IT BIT 60 AMP 0 MLO 120/208V 00 446, CU, 1-#10, CU, GRND, IN 1" C. EXISTING / MODIFIED ELECTRICAL POWER RISER DIAGRAM SCALE: N.T.S. RISER DIAG. NOTES: COORDINATE WITH LANDLORD AND VERIFY EXISTING DISC. SWITCH, METER, 75KVA XFRMR, FEEDERS AND CONDUITS ARE IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPUCABLE CODE. IF YES USE THEM. IF NOT UPGRADE THEM PER RISER DIAGRAM AND LL'S DESIGN CRITERIA. 0 VERIFY EXISTING AND INSTALL NEW GROUNDING SYSTEM IN COMPLIANCE WITH RISER DIAGRAM AND N.E.C. STD. #250, REQUIREMENTS. O3 RELOCATE AND REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE KEY NOTE #19, RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED TYPE. FURNISH AND INSTALL NEW SUBPANEL "5" IN COMPLIANCE WITH THE KEY NOTE #19, RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED TYPE. EQUIPMENT SCHEDULE MARK ITEM/RESPONSIBILITY CW IY. DIMS SPECIFICATIONS: REMARKS: 2 CASH REGISTER (OSCI) 2 16.6" W 16.8" D 11.7" H SHARP MODEL #ER -A530 WITH SPILL -PROOF KEYBOARD, 120 V 3 10 WELLS STEAM TABLE (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED, SEE SECTIONS. 208V, 3PH, 12 KW, 50 AMP & 208V, 1PH, 30 KW, 20 AMP 3.1 2 WELLS DROP-IN REFRIGERATED COLD PAN (OSCI) 1 29-3/4" W 24" D 19-5/8" H ATLAS METAL MODEL #WCM-2 3.9 AMPS. -120V-1/5HP CUT-OUT REQUIRED: 22-1/4" D x 28" W NEMA 5-15P 3/4" I.D. 4 SOUP/NOODLE WARMER (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED. 208V, 3PH, 9 KW, 25 AMP 5 SNEEZE GUARD (OSCI) 2 VARIES SEE PLAN CUSTOM FABRICATED WITH LIGHT FIXTURE 120 V FOR LIGHT FIXTURE 6 UNDERCOUNTER BAG -IN BOX (OSCI) 1 COKE CO. 7 SODA DISPENSER/ ICE BIN (OSCI) 1 COKE CO. FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE COUNTER TOP. FITS CUT OUT MEASURING 23-1/4"x23-1/4" CONTACT SANDY MANUEL(813)973-3465 TO COORD. DELIV. 10 MENU BOARD (SSCI) 8 VARIES SEE PLAN CUSTOM FABRICATED LCD PANELS 20 COMBI OVEN (OSCI) 1 33-1/4" W 30-3/8" D 30-3/4" H RATIONAL MODEL #A619106.12.202 30.8 AMPS 208/3P 11.1 KW. 1/2" COLD WATER AND 2" DRAIN LINE STEAM TEMPERATURE RESISTANT DRAIN. 26 EXH. HOOD (OSCI) 1 24"H EXISTING TO REMAIN. W/LIGHT FIXTURES. LENGTH & WIDTH VARY, SEE PLAN. ANSUL SYSTEM TANKS AND CONTROL PANEL 1 "ANSUL" PRE -ENG. LIQUID CHEMICAL FIRE SUPPRESSION SYS. W/FIXED NOZZELS. SYS. TO BE UL CLASSIFIED AND INSTALLED PER NFPA #96 REQ. SYSTEM SHALL BE CAPABLE OF AUTOMATIC AND MECH. OPERATION W/AUTO SOLINOID GAS VALVE SHUT DOWN. ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. MIN HGT. TO BOTT. OF UNIT TO BE 6'-6' AFF. NOTE: NOZZELS AND PIPING IN PUBLIC VIEW SHALL BE CHROME FINISHED. ELEC: FOR EMERGENCY SHUT OFF, CONNECT CONTROL PANEL TO SOLINOID FOR SHUT DOWN OF GAS SUPPLY UPON ACTIVATION. PLUMB:CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. NEW SUBPANE MCB: N/A MLO: 60 AMP A.I.C.: 10,000 AMP VOLTS: 120/208 V PHASE: 3, S/N WIRE: 4 MTD: RECESS WITH EQUIPMENT GROUND BUSSES BLDG: RUBY THAI KITCHEN TOTAL 2.05 1.40 1.71 LEGEND R RECEPTACLE K KITCHEN EQUIPMENT 1.50 1.98 1.63 TOTAL OA DESCRIPTION OF LOAD BRKR KVA PH LOAD CIR NO PHASE CIR NO KVA PH LOAD BRKR DESCRIPTION OF LOAD 28 6A OB OC P AMP A B C AMP P OA OB OC K U.C. REFRIG, DISPLAY (#50) 20 1 0.58 1 a 2 1.00 1 20 BAG -N -BOX SODA RACK (#6) K SANDWICH TOP REFRIG. (#39a) 0.90 3 a 4 0.98 WORKTOP COOLER (#41.1) SANDWICH TOP REFRIG. (#39) 1.00 5 a 6 0.63 2 DOOR REACH -IN COOLER (#48) v " SODA DISPENSER (#7) 1.00 7 a 8 0.50 RECEPT. R R RECEPT. 0.50 9 a 10 1.00 RECEPT. K WORKTOP FREEZER (#41) 0.71 11 a 12 1.00 .s, \,. RECEPT. N.,- �, .,.., REFRIG. COLD PAN (#3.1) „ ,, 0.47 13 a 14 SPACE SPACE 15 0 16 4, 17 a 18 v TOTAL 2.05 1.40 1.71 LEGEND R RECEPTACLE K KITCHEN EQUIPMENT 1.50 1.98 1.63 TOTAL OA OB OC 3.55 3.38 3.34 TOTAL CONNECTED KVA 30 29 28 TOTAL CONNECTED AMPS LOAD ANALYSIS LOAD VOLT CONNECTED (KVA) FACTOR LIGHTING 120 6.15 125% DEMAND (KVA) 7.69 CONV. OUTLETS 120 3.80 100% 3.80 MISC. 120 0.30 100% 0.30 KITCHEN EQUIP. 120/208 45.41 65% 29.52 WATER HEATER 208 4.50 65% 2.93 MOTOR 208 6.00 125% 7.50 OTHERS 100% TOTAL 66.16 51.74 PANEL A-31 TIME CLOCK "TC" 365 DAYS ASTRONOMICAL PROGRAMMABLE MANUAL OVERRIDE SWITCH "TR" eKo ELECTRICALLY HELD CONTACTOR (TYP.) A-41 -rm A-42 -.114 SPARE -ad - TO LIGHTING as- INTERIOR LIGHTING CONTROLS a THE TIME CLOCK SHALL PROVIDE 365 DAYS, ADVANCE HOLIDAY, ASTRONOMICAL PROGRAMMABLE SHUT OFF SWITCH AND 0-2 HOURS MAXIMUM OVERRIDE SWITCH a THE TIME CLOCK CAN BE INTERMATIC ET 7000 SERIES: a THE TIME CLOCK SHALL HAVE BATTERY BACKUP 78 HOURS MIN. TIMER CONTROL FOR SIGNS AND LIGHTS SCALE: N.T.S. 120/208, 30 POWER SUPPLY CALCULATIONS: 1. TOTAL DEMAND LOADS 2. DEMAND CURRENT/0 4. EXISTING PANEL "A" 3. EXISTING POWER SUPPLY = 51.74 KVA = 144 AMPS @ 120/208V,30 = 200 AMP, MCB, 120/208V, 30, 4W. = 200 AMPS, 120/208V, 30, 4W. 29 ICE MAKER (OSCI) 1 1 CUBER: 30" W 24.50" D 21.50" H BIN: 30" W 34"D 44" H MANITOWOC MODEL #QY-0605W 208-230/60/1, AIR COOLED, 9.2 AMPS, 1 HP 9,000 BTU/HR (AVERAGE) MANITOWOC MODEL #S-570 ON 6" LEGS ALLOW 6" AIR CLEARANCE @ BACK OF UNIT. ELEC.: SIMPLEX @ 80" A.F.F. (3 WIRE WITH NEUTRAL FOR 115V) PROVIDE 6' CORD AND PLUG TO UNIT. PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & CUBER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT WASTE FROM CONDENSER TO FLOOR DRAIN. MAINFOLD AS REQUIRED. 39 SANDWICH TOP REFRIGERATOR (OSCI) 1 60"W 34-1/8" D 40-3/8" H TRUE MODEL #TSSU-60-24M-B-ST 115/60/1, 7.8 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION 39a SANDWICH TOP REFRIGERATOR (OSCI) 1 48-3/8" W 34-1/8" D 40-3/8" H TRUE MODEL #TSSU-48-18M-B 115/60/1, 8.6 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION 40 UNDERCOUNTER WATER HEATER (CSC►) 1 32-1/4" H 26-1/2" DIA EXISTING TO REMAIN STATE MODEL #PATRIOT PCE 50 2OLSA 50 GAL, 4.5 KW, 208V, 1PH 41 WORKTOP FREEZER (OSCI) 1 48-3/8" W 30-1/8" D 39-1/2" H TRUE MODEL#TWT-48F 115/60/1, 6.1 AMPS, 1/2 HP 5.15P NEMA CONFIGURATION 41.1 WORKTOP COOLER (OSCI) 1 72-3/8" W 31-1/8" D 39-1/2" H TRUE MODEL #TWT -72 115/60/1, 8.5 AMPS,1/3 HP 5-15P NEMA CONFIGURATION 47 3 DOOR COOLER (OSCI) 1 78-1/8" W 29-1/2" D 83-3/8" H TRUE MODEL #T-72 115/60/1, 9.6 AMPS, 1/2 HP - 5 -15P NEMA CONFIGURATION 48 2 DOOR COOLER (OSCI) 1 54-1/8" W 29-1/2" D 83-3/8" H TRUE MODEL #T-49 115/60/1, 5.4 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION 50 UNDERCOUNTER REFRIGERATED DISPLAY (OSCI) 1 48-3/8"W 30-1/8"D 29-3/4"H TRUE MODEL #TUC -48G 115/60/1, 1/5 HP,SAMPS- 5-15P NEMA CONFIGURATION 51 ELECTRICAL PANEL (CSCI) 2 ONE EXISTING RELOCATED AND ONE NEW TIE TO A-31 H N RELAY SQ."D" CLASS 8501 TYPE XM040-V02 120 VAC COIL, NEMA 1 ENCLOSURE, CLASS - 9991-UE7. r-- SHUNT TRIP BREAKER USED FOR UNDER HOOD COOKING EQUIPMENT -1 j0 o Foto SPARE L , J r L r NI 0 I I--( 1 CONTACT FROM FIRE DETECTION SYSTEM. J CONTACT LOCATED IN ANSUL SYSTEM CONTROL HEAD. GAS SUPPLY SOLENOID VALVE SHUNT TRIP RELAY CONTROL NO SCALE (1) SEQUENCE OF OPERATION: UPON ACTIVATIOIOF THE ANSUL SYSTEM, AND/OR FIRE DETECTION SYSTEM. ALL EQUIPMENT UNDER HOOD, RTU -1 UNIT FAN, MAKEUP AIR FAN, AND GAS SUPPLY SOLENOID VALVE SHALL AUTOMATICALLY SHUT DOWN. EXHAUST FANS SHALL BE LOCKED IN "ON" POSITION. tL1O(32 RECEI CITY OF TUKWILA FEB 21 2017 PERMIT CENTER REVIE COMPLIA NFPA MAR DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: Mins WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA •4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 t1 SEAL REGISTERED ARCHITECT DAVID W. HIATT STATE OF WA$HINOTOM ED F8 ►NEL SCHEDULES, CE WISER DIAGRAM NEC AND DETAILS 2 017 City of ILDIN SHEET NUMBER ukwlla DIVISION E2.0 ELECTRICAL SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION WORK 1.0 GENERAL 1.1 BIDDERS QUAUFI CATIONS AND INSTRUCTIONS: 1.1.1 QUALIFICATIONS: THE BIDDERS SHALL BE QUALIFIED, EXPERIENCED, AND UCENSED ELECTRICAL CONTRACTORS. THEY MUST BE FAMILIAR WITH ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES, AND REGULATIONS THAT MAY, IN ANY MANNER, AFFECT THE TASK. 1.1.2 BIDDING INSTRUCTIONS: BEFORE SUBMITTING THE BID, THE BIDDERS MUST REVIEW THE TENANT INFORMATION AND CRITERIA MANUAL, SPECIFICATIONS, PLANS, DRAWINGS, AND ALL OTHER CONDITIONS AND REQUIREMENTS THAT MAY, IN ANY MANNER AFFECT THE WORK UNDER CONTRACT. THEY MUST VISIT THE SITE OFTHE PROPOSED PROJECT TO FAMILIARIZE THEMSELVES WITH THE LOCAL CONDITIONS, FIRE RATING REQUIREMENTS, AND THE NATURE OF THE PROJECT. THE PRICING SHALL BE BASED ON THESE SPECIFICATIONS AND THE MATERIALS SHOWN ON THE DRAWINGS. SUBMISSION OF THE BIDS SHALL BE CONSIDERED AS THE EVIDENCE THAT THE BIDDER IS FAMILIARIZED TO ALL THE FACETS OF THE SPECIFIED PROJECT. CONTRACTOR SHALL USE APPLICABLE SECTIONS OF THIS SPEC. 1.1.3 EXCEPTIONS: ANY EXCEPTIONS, OMISSIONS, DISCREPANCIES, AND DOUBTS REGARDING PLANS, DRAWINGS, AND SPECIFICATIONS, IF ANY, SHALL BE COMMUNICATED PROMPTLY IN WRITING TO THE ARCHITECT OR TO THE ENGINEER FOR THEIR REVIEW AND RESPONSE BACK BEFORE THE BID SUBMISSION DATE. NO ORAL COMMUNICATION REGARDING THE EXCEPTIONS OR CHANGES SHALL BE ACCEPTED. BIDDERS SHALL BE NOTIFIED OF ANY CHANGES, IF MADE, DUE TO THE ACCEPTANCE OF EXCEPTIONS BEFORE THE BID SUBMITTAL DATE. 1.1.4 MATERIAL TAKE OFF: ALL MATERIALTAKE OFFS, OTHER THAN THE EXISTING DEVICES, SHALL BE MADE USING THE LIGHT & POWER WIRING AND CONDUIT DRAWINGS AND THEIR ASSOCIATED REFERENCES INCLUDING THE SPECIFICATIONS OF THIS PROJECT ON THIS DRAWING. ALL LIGHTING MATERIALS INCLUDING TRANSFORMER, PANELS, FIXTURES, SWITCHES, RECEPTACLES, WIRES AND RACEWAYS, ETC. SHALL BE PURCHASED BY THE CONTRACTORS PER SECTION NO. 2, UNLESS NOTED OTHERWISE. 1.1.5 BID PRICE: THE BID PRICE SHALL INCLUDE LABOR AND MATERIAL COSTS, NECESSARY INSURANCE COSTS AND PERMITS FEES AS REQUIRED TO INSTALL THE COMPLETE ELECTRICAL SYSTEM IN COMPLIANCE WITH THE DESIGN REQUIREMENTS OF THIS PROJECT. 1.1.6 SUCCESSFUL BIDDER: THE SUCCESSFUL BIDDER WILL BE REFERENCED AS THE CONTRACTOR FROM THIS POINT ONWARDS THROUGHOUT THE REST OF THE SPECIFICATION. 1.2 THE ELECTRICAL CONTRACTOR REQUIREMENTS AND INSTRUCTIONS: 1.2.1 THE CONTRACTOR SHALL USE EXPERIENCED AND SKILLED PERSONS TO PERFORM ALL THE ELECTRICAL INSTALLATION WORK UNDER THE CONSTANT SUPERVISION OF LICENSED ELECTRICIANS AND/OR LICENSED JOURNEYMAN ELECTRICIANS. 1.2.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, PAYING ALL FEES, AND PROVIDING ALL NECESSARY INSPECTIONS INCIDENTAL TO THE ELECTRICAL PORTION OF THE WORK. 1.2.3 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARRYING NECESSARY INSURANCE AS REQUIRED BY LAW TO PROTECT EMPLOYEES, OTHER PERSONS, EQUIPMENT, AND MATERIAL 1.2.4 THE INSTALLATION WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL BUILDING CODES. APPLICABLE CODES, AS A MINIMUM, WILL INCLUDE THE LATEST EDITION OF THE FOLLOWING. THESE WILL BE CONSIDERED PART OF THE SPECIFICATION OF THIS PROJECT. A) BUILDING CODE OF THE APPLICABLE CITY AND COUNTY. 8) NATIONAL ELECTRIC CODE NFPA 70, 2008 C) LIFE SAFETY CODE NFPA 101, 2006 D) S.B.C.C.I. LATEST EDITION. 1.2.5 IN CASE OF SUBSTITUTIONS THE CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST TO THE ARCHITECT FOR HIS REVIEW . THE CONTRACTOR SHALL IDENTIFY CLEARLY THE DIFFERENCE BETWEEN THE SPECIFIED ITEMS AND THE SUBSTITUTE ITEMS, INCLUDING THE ECONOMIC IMPACT ON THE PROJECT. THE SUBSTITUTE ITEM SHALL NOT BE ORDERED OR USED UNLESS APPROVED BY THE ARCHITECT AND/OR BY THE OWNER IN WRITING. 1.2.6 THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS FOR SPECIFIED PRODUCTS AT ONE TIME WITHIN THIRTY (30) DAYS FROM THE OFFICIAL NOTICE TO PROCEED. SHOP DRAWING SUBMITTAL SHALL BE MADE FOR THE FOLLOWING MATERIALS AND SYSTEMS: A. B. C. D. LIGHTING FIXTURES, DIMMERS, LAMPS, AND SAFETY SWITCHES. TRANSFORMERS, SWITCH BOARDS, DISTRIBUTION PANELS , DISCONNECTS, AND WIREWAYS IF PURCHASED NEW. METER CENTERS, CIRCUIT BREAKERS, FUSES, MOTOR STARTERS IF PURCHASED FOR THIS PROJECT. TIME CLOCK AND OTHER DEVICES. E)SCHEMATIC DIAGRAMS FORTHEABOVE ITEMS. 1.2.7 THE CONTRACTOR SHALL PROVIDE FOLLOWING DOCUMENTS BEFORE THE CLOSING OF THE PROJECT AND PRIOR TO THE FINAL PAYMENT: A. ONE YEAR WRITTEN WARRANTY FOR ANY DEFECT IN WORKMANSHIP, MATERIAL, AND EQUIPMENT. B. TWO SETS OF MANUFACTURER'S OPERATIONAL AND MAINTENANCE MANUALS IF APPLICABLE. C. MANUFACTURER'S WARRANTIES AND WARRANTY CERTIFICATES. D. TWO SETS OF REPRODUCIBLE OR RED MARKED UP PRINTS OF "AS -BUILT" DRAWINGS, ONE FOR THE ARCHITECT AND ONE FOR THE OWNER OF THE PROJECT. 1.2.8 THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY TEMPORARY ELECTRICAL POWER, AT HIS EXPENSE, AS REQUIRED BY HIS TRADE AND BY THE GENERAL CONTRACTOR. 1.2.9 THE CONTRACTOR SHALL MAKE SURE ON A DAILY BASIS THAT ALL UNNECESSARY MATERIAL AND TRASH CONTRIBUTED BY HIS TRADE ARE REMOVED. 1.2.10 THE CONTRACTOR SHALL CONCEALED ALL THE CONDUIT IN THE FINISHED AREAS. 2.0 PRODUCTS: 2.1 GENERAL: THE ELECTRICAL CONTRACTOR SHALL PURCHASE AND USE ALL "NEW' MATERIAL AS SPECIFIED AND SHOWN ON THE ELECTRICAL PLAN OF THIS PROJECT. ALL THE MATERIAL SHALL BE FREE FROM DEFECTS AND SHALL CARRY A "UL" LABEL 2.2 CONDUCTORS: ALL INSULATED CONDUCTORS SHALL BE UNCOATED COPPER OF 98% CONDUCTIVITY, 600 VOLT AC, DUAL RATED, TYPE THHN/THWN AS NECESSARY TO MEET THE DESIGN REQUIREMENTS AND THE APPLICABLE CODES. THW (FOR # 4 AWG AND LARGER) AND THERMO PLASTIC WIRES RATED FOR 75 DEGREES CENTIGRADE OPERATIONS IN WET AND DRY LOCATIONS AND 90 DEGREES CENTIGRADE WITHIN ELECTRIC DISCHARGE LIGHTING EQUIPMENT MAY BE USED. CONDUCTORS NUMBER # 10 AWG AND LOWER SHALL BE SOLID COPPER AND #8 AWG AND ABOVE SHALL BE STRANDED COPPER. THE MINIMUM SIZE OF WIRE SHALL BE # 12 AWG FOR 20 AMP BREAKER, # 10 AWG FOR 30 AMP BREAKER, # 8 AWG FOR 40 AMP BREAKER. 2.3 CABLE: SIGNAL CABLES, IF USED, SHALL BE COPPER AND SHALL MEET ALL UL AND N.E.C. CODE REQUIREMENTS. METAL CLAD (TYPE MC), ARMORED (TYPE AC) AND NON- METALLIC (NM) CABLES SHALL NOT BE USED. ALL CABLE ASSEMBLIES SHALL CONTAIN COPPER GROUND CONDUCTOR. 2.4 CONDUITS: THE CONDUITS SHALL BE ELECTRICAL METAWCTUBING (EMT) AND HOT DIPPED GALVANIZED STANDARD STEEL AS MANUFACTURED BY WHEATLAND TUBE COMPANY OR EQUIVALENT. 2.5 OUTLET BOXES AND FITTINGS: OUTLET BOXES, FITTING CLAMPS AND HANGERS ETC. SHALL BE GALVANIZED STEEL, RUST RESISTANT AND COMPATIBLE WITH THE RACEWAY. OUTLET BOXES FOR FIXTURES, SWITCHES, AND RECEPTACLES SHALL HAVE SMOOTH ROUND EDGES AND SHALL BE WITH COVER PLATES. BOXES SHALL BE"STEEL CITY" OR EQUIVALENT. FITTINGS FOR EMT CONDUITS SHALL BE COMPRESSION TYPE. NO SET SCREW WILL BE USED, UNUSED HOLES SHALL BE COVERED WITH APPROVED INSERT CAPS. 2.6 SWITCHES AND DIMMERS: SWITCHES AND DIMMERS SHALL BE TOTALLY ENCLOSED, RATED AT 120/277 VOLTS AC, 20 AMPS, 2000 WATTS WITH GRAY TOGGLE AND DEVICE PLATE. THESE SHALL BE QUIET OPERATION, COMMERCIAL GRADE AS MANUFACTURED BY LEVITON, LUTRON OR EQUIVALENT. PLATES SHALL MATCH THE SWITCHES. FURNISH IN GANGS AS NECESSARY. 2.7 RECEPTACLES: RECEPTACLE SHALL BE COMMERCIAL GRADE, 125 VOLTS AC, AND 20 AMPERE RATING WITH GROUNDED POLE AND TWO CIRCUIT OPTION, AS MANUFACTURED BY LEVITON OR EQUIVALENT. PLATES SHALL MATCH THE RECEPTACLES. FURNISH IN GANGS AS NECESSARY. 2.8 DEVICE PLATES: PROVIDE DEVICE PLATE FOR EACH AND EVERY OUTLET BOX. FURNISH IN GANGS AS NECESSARY. PLATES AND SCREWS SHALL BE GRAY UNLESS THE OWNER PREFERS SOME OTHER COLOR, AND SHALL BE OF THE SAME MANUFACTURER AS OF THE DEVICES. 2.9 BALLASTS: BALLASTS FOR FLUORESCENT FIXTURES SHALL BE RAPID START, SYLVANIA ELECTRONIC ENERGY SAVING, HIGH POWER FACTOR AND SHALL BE CLASS "P," CBM, TITLE 24 CERTIFIED WITH INTERNAL THERMAL PROTECTOR WITH AUTOMATIC RESET AND CLASS "A" SOUND RATING NOISE LEVELS LESS THAN 30 dB MAXIMUM. BALLASTS SHALL BE MANUFACTURED BY SYLVANIA AS SHOWN ON THE LIGHTING SCHEDULE OR EQUAL EQUAL AND SHALL SHALL BE GUARANTEED AT LEAST FOR FIVE (5) YEARS OF OPERATION AFTER THE ACCEPTANCE. THE BALLAST MODEL NUMBER SHALL BE "2 OR 4 LAMP PSX-SYLXtreme AS REQUIRED". 2.10 LAMPS: LAMPS SHALL BE MANUFACTURED BY SYLVANIA MODEL # SYL "F028/841XP/SS/ECO OR EQUIVALENT. ALL LAMPS SHALL BE GUARANTEED FOR AT- LEAST 4 YEARS OF OPERATION AFTER THE ACCEPTANCE. 2.11 LIGHTING DEVICES: ALL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTS SHALL BE AS LISTED ON THE LIGHT FIXTURE SCHEDULE; HOWEVER BEFORE PURCHASING ANY LIGHT FIXTURES, SUBMIT FIXTURE. CUT SHEETS FOR THE ARCHITECT AND THE OWNER'S APPROVAL. 2.12 TIME CLOCK OR TIME SWITCH: TIME CLOCK SHALL BE ELECTRO -MECHANICAL 24 HOURS SEVEN DAYS TYPE WITH RESERVE POWER AND CONTACTS RATED 40 A. 4 PST AND N.E.M.A. TYPE 1 OR 3R ENCLOSURE. IT SHALL BE SELF POWERED BY A SELF STARTING SYNCHRONOUS MOTOR WITH MINIMUM 16 HR SPRING DRIVEN RESERVE POWER AND A DAY OMITTING DEVICE. TIME CLOCK SHALL BE PARAGON 7007-0, TORK "W" SERIES, OR APPROVED EQUAL 2.13 GUARANTEE: ALL ELECTRICAL EQUIPMENT, MATERIAL AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. 3.0 INSTALLATION INSTRUCTIONS: 3.1 GENERAL: THE PLAN LOCATION OF LIGHTING FIXTURES, JUNCTION BOXES, CONVENIENCE OUTLETS, AND PANEL BOARDS ARE APPROXIMATE UNLESS DIMENSIONED AND ARE TO BE ADJUSTED BY THE CONTRACTOR AS REQUIRED IN THE AREAS WHERE CEILING GRID AND OTHER OBSTRUCTIONS DETERMINE FIXTURE LOCATIONS. THE CONTRACTOR SHALL COORDINATE WITH OTHER ARCHITECTURAL, MECHANICAL AND OTHER SYSTEMS TO AVOID INTERFERENCE. ALL CUTTING AND CONSEQUENT REPAIRS IN CONJUNCTION WITH THE WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. BEAMS OR OTHER STRUCTURAL COMPONENT SHALL NOT BE CUT WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT. 3.2 3.3 3.4 3.5 THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, LABOR, TRANSPORTATION, RIGGING & HOISTING, TOOLS, AND STORAGE, ETC. FOR ALL WORK INDICATED AND REQUIRED FOR COMPLETE INSTALLATION. THE ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP SHALL BE THE HIGHEST QUALITY AS ESTABUSHED BY TRADE STANDARD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND COMMUNICATIONS WITH THE LOCAL BUILDING DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. OWNER WILL NOT BE HELD RESPONSIBLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR'S ERROR OR OMISSION OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE. 3.6 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES PLACEMENT, AS IDENTIFIED ON THE RISER DIASRAM, AND LOCATION OF THE ELECTRICAL SERVICE EQUIPMENT. THE CONTRACTOR SHALL PAY ALL NECESSARY CHARGES ASSOCIATED WITH INSTALLATION OF ALL UTILITIES TO THE POWER COMPANY PRIOR TO THE CONSTRU_TION. A LETTER SHALL BE PROVIDED FROM THE POWER COMPANY THAT ALL THE CHARGES HAVE BEEN PAID IN FULL 3.7 NECESSARY AND OBVIOUSLY REQUIRED, ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS, SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO INSTALL A COMPLETE AND SAFE ELECTRICAL SYSTEM. 3.8 THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE THROUGI-OUT THE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS. 3.9 ALL SLAB OR ROOF PENETRATIONS SHALL BE MADE WITH APPROVED FIRE RATED SMOKE BARRIER FITTINGS. PROVIDE ACCESSORIES (PITCH POCKETS, SLEEVES, ETC.) AS REQUIRED. 3.10 JUNCTION BOXES FOR NEON SIGN LIGHTS, SWITCHES, LIGHTING FIXTURES, RECEPTACLES AND FOR PULLING WIRES SHALL BE AS APPROXIMATE AS SHOWN ON THE PLANS BUT EXACT LOCATIONS SHALL BE GOVERNED BY THE ARCHITECTURAL PLANS. 3.11 ALL OUTLET BOXES SHALL HAVE SQUARE CUT CORNERS. AIR SPACE GREATERTHAN 1/8" AROUND OUTLET BOXES, AND ADJACENT DRYWALL WILL NOT BE PERMITTED. THE CONTRACTOR SHALL COORDINATE WITH DRYWALL INSTALLER PRIOR TO INSTALLATION. CAULK AROUND BOXES TO ELIMINATE STEEL OUTLET. 3.12 LIGHTING SWITCHES AND CONVENIENCE RECEPTACLES SHALL BE FLUSH MOUNTED IN SECTIONAL SWITCH BOXES WITH MATCHING COVER PLATES UNLESS NOTED OTHERWISE. 3.13 THE MOUNTING ARRANGEMENT OF EACH FIXTURE WELL BE DETERMINED BY THE CONTRACTOR EXCEPT WHERE THE MANUFACTURER HAS GIVEN SPECIFIC MOUNTING INSTRUCTIONS. 3.14 THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LUMINARIES, DEVICES, AND EQUIPMENT AS SPECIFIED AND SHOWN ON THE PLAN DIAGRAMS. PROVIDE ALL CABLES, CONDUCTORS, CONDUITS, AND CONNECTIONS AS REQUIRED TO PROVIE'E COMPLETE AND OPERATIONAL ELECTRICAL AND MECHANICAL SYSTEMS. ALL CONDUITS SHALL BE RUN CONCEALED IN FINISHED AREAS. 3.15 INDIVIDUAL BREAKERS WILL SUPPLY ELECTRICAL POWER TO INDIVIDUAL SIGN OR NEON LIGHT CIRCUITS. NEON TRANSFORMER EQUIPMENT IS TO BE CONCEALED ABOVE ADJACENT COLUMN ENCLOSURE OR TO BE INSTALLED AS SHOWN 011 ARCHITECTURAL DRAWINGS. 3.16 ALL JOINTS IN CONDUIT AND RACEWAY SHALL BE MADE TIGHT AND BENDS SHALL BE MADE OVER LONG RADIUS WHERE ENTERING A CABINET AND JUNCTION BOX. THE CONTRACTOR SHALLSUPPORT ALL CONDUIT AND RACEWAYS SECURELY FROM JOISTS AND/OR BEAMS (TIE WIRES ARE NOT ACCEPTABLE). THE CONTRACTOR SHALL VERIFY ALL RACEWAY SIZES IN ACCORDANCE WITH THE N.E.C. CODE. NO CONDUIT SHALL CARRY MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS. NOTE: ALL JOB CUT THREADS SHALL BE COATED WITH RUST RESISTANT ZINC CHROMATE FOR THIN WALL EMT. 3.17 LIGHTING CONDUITS SHALL BE SUPPORTED AT EVERY 8 FEET. 3.18 MOUNTING HEIGHT OF LIGHTING EQUIPMENT, UNLESS NOTED OTHERWISE ON ARCHITECTURAL PLANS SHALL BE APPROXIMATELY AS FOLLOWS: A. LIGHTING SWITCHES CENTERLINE B. CONVENIENCE OUTLETS CENTERLINE C. UGHTING & POWER PANELS TOP D. EMERGENCY LIGHT FIXTURES 4 FEET ABOVE A.F.F 1 FEET, 6 INCHES A.F.F 6 FEET, 6 INCHES ABOVE A.F.F 9' ABOVE A.F.FTO BOTTOM OFTHE UNIT. 3.19 ELECTRICAL RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.), ARTICLE 250. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. ISOLATED GROUND CONDUCTORS SHALL BE ROUTED TO THOSE CIRCUITS WHICH NEED ISOLATED GROUND SPECIALLY FOR COMPUTERS AND CASH REGISTERS. 3.20 THE CONTRACTOR SHAD. PROVIDE LIGHTNING PROTECTION VOLTAGE SURGE PROTECTOR FOR ALL SERVICE PHASE CONDUCTORS TO GROUND (IF IT IS NOT ALREADY THERE IN CASE OF RENOVATIONS). DEVICE SHALL BE APT TE 400 OR APPROVED EQUIVALENT. 3.21 LUMINARIES SHALL BE AS SPECIFIED IN THE "LIGHTING FIXTURE SCHEDULE". ALL RECESSED AND LAY -IN FIXTURES SHALL BE SUPPORTED FROM THE FOUR CORNERS WITH SUPPORTS CAPABLE OF CARRYING TWICE THE WEIGHT OF THE FIXTURE. ALL SUPPORTS SHALL BE ATTACHED TO THE JOISTS AND/OR BEAMS. NO LIGHTING FIXTURE SHALL BE INSTALLED WITHIN 2 FEET OF ANY SPRINKLER HEAD. 3.22 THE CONTRACTOR SHALL INSTALL ALL TELEPHONE JACKS AND WIRING FROM THE MAIN TELEPHONE TERMINAL BOARD TO THE FINAL TELEPHONE OUTLETS. WIRING SHALL BE INSTALLED IN A MINIMUM 1/2 INCH CONDUIT. 3.23 THE CONTRACTOR SHALL COORDINATE WITH THE FIRE PROTECTION CONTRACTOR AND SHALL MAKE ALL NECESSARY CONNECTIONS BETWEEN DUCT SMOKE DETECTORS AND HVAC UNITS. 3.24 ALL JUNCTION BOXES SHALL BE ACCESSIBLE FROM BELOW. OTHERWISE, CONTRACTOR SHALL PROVIDE ACCESS PANEL AT ALL JUNCTION BOX LOCATIONS AND SMOKE DETECTORS. 3.25 IF NOT ALREADY EXISTING, THE CONTRACTOR SHALL FURNISH ALL THE NECESSARY DISCONNECT SWITCHES, RELAY BOXES, ANDCONTROL BOXES AS REQUIRED AND RECOMMENDED BY THE HVAC MANUFACTURER FOR THE HVAC UNIT AND WATER HEATER. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE ALL NECESSARY CONNECTIONS TO MAKE THE HVAC SYSTEM FUNCTIONAL. 3.26 A PLASTIC COVERED TYPE WRITTEN IDENTIFICATION CARD FOR ALL MAIN AND BRANCH CIRCUITS INCLUDING SPARES SHALL BE POSTED AT THE INSIDE OF THE PANEL DOOR. 3.27 LOCK -ON DEVICES ON PANEL CIRCUIT BREAKERS FOR NIGHT, EXIT AND EMERGENCY LIGHTING CIRCUITS SHALL BE PROVIDED AND THE SHALL BE GIVEN TO THE OWNER. 3.28 LOW VOLTAGE WIRING LOCATED ABOVE THE CEILING SHALL BE PLENUM RATED OR INSTALLED IN METAL CONDUIT. 4.0 TRANSFORMER AND PANEL BOARD SPECIFICATIONS : THIS SECTION SHALL APPLY TO THE NEW TRANSFORMER, PANEL BOARDS, CIRCUIT BREAKERS, PANEL BOXES & TRIMS, DISCONNECTSWITCHES, AND FUSES. 4.1 PANEL BOARDS: PANEL BOARDS SHALL BE GENERAL PURPOSE N.E.M.A. TYPE 1 OR TYPE 3R ENCLOSURES SUITABLE FOR SPECIFIED INDOOR OR OUT DOOR LOCATIONS AND AND FLUSH OR SURFACE MOUNTING APPLICATIONS AS INDICATED ON THE PANEL SCHEDULE. PANEL BOARDS AND THE INTERNAL COMPONENTS SHALL BE RATED TO PERFORM THEIR FUNCTIONS CONTINUOUSLY AT 40°C AMBIENT AND 50% RELATIVE HUMIDITY. BUSSES, AND LUGS SHALL BE RATED AND CAPABLE TO FUNCTION CONTINUOUSLY AT 75 DEGREES CENTIGRADE. PANEL BOARDS SHALL BE AS MANUFACTURED BY WESTINGHOUSE ELECTRIC CORP., GENERAL ELECTRIC, SQUARE 'D', CHALLENGER, OR APPROVED EQUAL A NAMEPLATE USTING PANEL NUMBER, TYPE, MANUFACTURER'S NAME, NUMBER OF PROTECTIVE AND SWITCHING DEVICES, VOLTAGE, CURRENT, PHASE AND AIC RATINGS SHALL BE PROVIDED. BRANCH CIRCUITS SHALL BE ARRANGED USING DOUBLE ROW CONSTRUCTION. ALL INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED WITH SWITCHING AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC. ALL WIRE CONNECTORS, EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI -TURN SOLDERLESS TYPE AND ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED ON DRAWINGS OR IN THE PANEL SCHEDULES AND CONTINUOUSLY FUNCTIONING AT 75 DEGREE CENTIGRADE. ALL BREAKERS, SIZED AS SHOWN ON PANEL SCHEDULE, SHALL BE BOLT -ON BREAKERS. INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND SHALL BE SO DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING, OR TAPPING. BUS BARS FOR THE MAINS SHALL BE OF COPPER AND SIZED IN ACCORDANCE WITH UNDERWRITERS' LABORATORIES STANDARDS. UNLESS NOTED OTHERWISE, FULL SIZE NEUTRAL BARS SHALL BE INCLUDED. BUS BAR TAPS FOR PANELS WITH SINGLE POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIRCUIT DEVICES. THE SHORT CIRCUIT RATING OF THE ASSEMBLED PANEL BOARD SHALL BE IN ACCORDANCE WITH UL. INC. STANDARDS AND THEIR TEST VERIFICATION. PHASE BUSSING SHALL BE FULL HEIGHT WITHOUT REDUCTION. CROSS AND CENTER CONNECTORS SHALL BE COPPER. NEUTRAL AND GROUND BUSSING SHALL HAVE SUITABLE LUGS FOR OUTGOING FEEDERS REQUIRING A NEUTRAL AND GROUND CONNECTIONS. SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES ON UGHTING AND APPLIANCE DISTRIBUTION PANELS SHALL BE BUSSED FOR THE MAXIMUM DEVICE THAT CAN BE FITTED INTO THEM. PROVIDE BLANK FILLER PLATES IN THE EMPTY SPACES. 4.2 CIRCUIT BREAKER: THE CIRCUIT BREAKERS ARE TO BE INDUSTRIAL MOLDED CASE BOLT ON TYPE, STANDARD THERMAL, MAGNETIC, WITH TRIP FREE MECHANISM, THREE POSITION HANDLES INDICATING "ON" "OFF" AND "TRIPPED" CONDITION. EACH POLE SHALL PROVIDE INVERSE TIME DELAY AND INSTANTANEOUS CIRCUIT PROTECTION. THE BREAKER RATING AND CONFIGURATION SHALL BE AS INDICATED ON THE PANEL BOARD SCHEDULE. ALL MULTI POLE BREAKERS SHALL HAVE AN INTERNAL COMMON TRIP. ALL BREAKER LUGS SHALL BE SUITABLE TO WITHSTAND 75 DEGREE CENTIGRADE WITHOUT MALFUNCTIONING. 4.3 PANELTRIM: HINGED DOORS IN PANEL TRIMS SHALL COVER ALL SWITCHING DEVICE HANDLES AND SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1. DOORS SHALL NOT UNCOVER ANY LIVE PARTS WHILE MAKING SWITCHING DEVICE HANDLES ACCESSIBLE. 2. DOORS SHALL HAVE FLUSH -TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER 48" IN HEIGHT SHALL HAVE AUXIUARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO FLUSH -TYPE CYLINDER LOCK AND CATCH. DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED ALIKE. DIRECTORY FRAME AND CARD HAVING A TRANSPARENT COVER SHALL BE FURNISHED ON EACH DOOR. THE TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL ALL EXTERIOR AND INTERIOR STEEL SURFACES OF THE PANEL BOARDS SHALL BE PROPERLY CLEANED PRIMED AND PAINTED IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND COLOR. TRIMS FOR FLUSH MOUNT PANELS SHALL OVERLAP THE BOX BY AT LEAST 3/4" ALL AROUND. SURFACE MOUNT PANELS TRIMS SHALL HAVE THE SAME WIDTH AND HEIGHT AS OFTHE BOX. TRIMS SHALL BE MOUNTABLE BY A SCREW DRIVER WITHOUT THE NEED FOR SPECIAL TOOLS. 4.4 PANEL BOXES: BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS ON THE TOP AND THE BOTTOM EXCEPT WHERE NOTED OTHERWISE. BOXES SHALL BE OF SUFFICIENT SIZE TO PROVIDE A MINIMUM GUTTER SPACE OF 4" ON ALL SIDES. WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE 50 SIZED AS TO INCLUDE THIS WIRING SPACE. THIS WIRING SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT LEAST FOUR (4) INTERIOR MOUNTING STUDS SHALL BE PROVIDED. ALL UNUSED HOLES IN THE BOXES SHALL BE PLUGGED WITH APPROVED INSERT CAPS. BOXES SHALL BE "STEEL CITY" OR EQUAL. 4.5 DISCONNECT SWITCH ES: THE CONTRACTOR SHALL INSTALL N.E.M.A. TYPE 1 DISC. SWITCHES FOR INDOOR AND N.E.M.A. TYPE 3R DISC. SWITCHES FOR OUT DOOR APPLICATIONS. ALL DISCONNECTSWITCHES FOR SERVICE CONDUCTOR ENTRANCES SHALL BE RATED AT LEAST 100K AIC. DISCONNECT SWITCHES FOR MOTOR CIRCUIT -AND FIXED LOAD (SUCH AS HVAC EQUIPMENT, AND WATER HEATER ETC.) CIRCUITS SHALL BE FUSIBLE OR NON FUSIBLE AS SHOWN ON THE DRAWINGS OR REQUIRED BY THE MANUFACTURER. 4.6 FUSE: THE CONTRACTOR SHALL USE DUAL ELEMENT; T1ME DELAY CURRENT UMITING, 100,000 AMP AIC RATED, CLASS RK -1 FUSES WHEN PROTECTING PANEL BOARDS AND TRANSFORMERS AND 100,000 AMP AIC RATED CLASS RK -5 FUSES WHEN PROTECTING MOTORS UNLESS NOTED OTHERWISE OR REQUIRED DIFFERENTLY BY THE MANUFACTURER. ALL FUSES IN ANY DISC.. SW SHALL BE OF THE SAME MANUFACTURER AND SHALL BE MANUFACTURED BY BUSSMANN, GOULD SHAWMUT OR EQUIVALENT. 0137- RECEIVED CITY OF TUKWI FEB 21 2017 PERMIT CENT REVI COMPL NFP DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: 1=1 A9 flU WESTFIELD SOUTHCENTER TUKILA, WA REVISIONS •4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL REGISTERED ARCHITECT VID W. HIATT STATE AOF WASHINGTON ELECTRICAL SPECIFICATIONS ED .FOR A MAR 0 2 2017 City UILDI f Tukwila NE 3 . Q G DIVISIO