Loading...
HomeMy WebLinkAboutPermit EL17-0154 - AVURE TECHNOLOGIES - SERVICEAVURE TECHNOLOGIES 4475 S 134 PL ELI 7-0154 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2613200084 4475 S 134TH PL BLDG B Project Name: AVURE TECHNOLOGIES ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL17-0154 3/28/2017 9/24/2017 Owner: Name: Address: Contact Person: Name: Address: REALTY ASSOCIATES FUND X LP 1301 DOVE ST#860, NEWPORT BEACH, WA, 92660 REX COLLINS 4826 B ST NW STE 101, AUBURN, WA, 98001 Contractor: Name: KIRBY ELECTRIC INC Address: 4826 B ST NW #101, AUBURN, WA, 98001 License No: KIRBYE1077BN Lender: Name: Address: Phone: (253) 859-2000 Phone: (253=) 859-2000 Expiration Date: 1/13/2019 DESCRIPTION OF WORK: ADDING 300A 480V SERVICE WITH TENANT IMPROVEMENT Valuation of single family: $0.00 Valuation of mf/comm: $45,000.00 Type of Work: Fees Collected: $1,181.66 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date:14/1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date:3 / e / 7 Print Name: /` �C® /�r This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW_ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: q)//,(blm (For office use o Iv) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4475.5134th P1$ King Co Assessor's Tax No.: Suite Number: New Tenant: Tenant Name: Avurr Technologies PROPERTY OWNER Name: Rex Collins Address: 4826 B St NW #101 Name: Avurc Technologies Phone: (253) 263-2064 Fax: (253) 859-2363 Email: Address: 4475 134th P1 S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Rex Collins Address: 4826 B St NW #101 City: Auburn State: WA Zip: 98001 Phone: (253) 263-2064 Fax: (253) 859-2363 Email: Floor: ❑ Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Kirby Electric Inc Address: 4826 B St. NW #101 City: Auburn State: WA Zip: 98001 Phone: (253) 859-2000 Fax: (253) 859-2363 Contr Reg No.: KIRBYEI077BN Exp Date: Tukwila Business License No.; BUS -0992935 Valuation of Project (contractor's bid price): $ 45,000 Scope of Work (please provide detailed information): Adding 300A 480V service with tenant improvement. Will service be altered? m Yes ❑ No Adding more than 50 amps? II Yes ❑ No Type of Use: Commercial Type of work: O New ❑ Addition 0 Service Change ❑ Remodel ® Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication ❑ Temporary Service Property Served by: O Puget Sound Energy ® Seattle City Light H:\Applications\Forms-Applications On Line \2014 Applications\Electrical Permit Application Revised 1-1- 14.docz Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: JC Date: 02/27/2018 Print Name: Collins Day Telephone: (253) 859-2000 Mailing Address: 4826 B St NW #101 Auburn WA 98001 City H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY PAID PermitTRAK $306.00 EL17-0154 Address: 4475 S 134TH PL BLDG B Apn: 2613200084 $306.00 DEVELOPMENT $306.00 PERMIT REINSPECT FEE - AFTER HRS INSP FEE TOTAL FEES PAID BY RECEIPT: R11760 R000.359.000.00.01 0.00 $306.00 $306.00 Date Paid: Tuesday, June 20, 2017 Paid By: KIRBY ELECTRIC Pay Method: CHECK 519854 Printed: Tuesday, June 20, 2017 1:08 PM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT QUANTITY PermitTRAK = PAID - $1,181.66 EL17-0154 Address: 4475 S 134TH PL BLDG B Apn: 2613200084 $1,181.66 ELECTRICAL $1,136.21 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $908.97 PLAN CHECK FEE R000.345.832.00.00 0.00 $227.24 TECHNOLOGY FEE - $45.45 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10934 R000.322.900.04.00 0.00 $45.45 $1,181.66 Date Paid: Tuesday, February 28, 2017 Paid By: KIRBY ELECTRIC Pay Method: CHECK 519420 Printed: Tuesday, February 28, 2017 9:08 AM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit tPERTOL�� MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:/0 �-. [T� r Type of Inspection:,Ct M — r� `— Address: 4r -S- (3cf Date Called: Special Ins r tions: Date Wanted: t° a.m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: tv.ck)E /44-1 Inspector: Date: REINSPECT! f N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: v o / f - Type of Inspection: LI LCL6-Pkr4 Gr k -CJ V Address: 111175 ,5-13 P Date Called: - to of kc -c-61, getm - 6,6C-1 cA-44v r 6 (-At r1 A -c- --t c� Special Instructions: - 1155 cdci Cp nlAtn ja PPok rr ovrektkei. Date Wanted:. j a.m. P -nip Requester: Phone No: `" V J y 5. 7 �t 0 Approved per applicable codes. giCorrections required prior to approval. COMMENTS: -0e- - C-tt&ckeicf uc ?b gE ®,J e-0(4-E-- LI LCL6-Pkr4 Gr k -CJ V o,fr 06AP ,far WO kr--01- - - Pu (C©( -0c 3 j R.ea%)AQ-9) Ko 1\ - to of kc -c-61, getm - 6,6C-1 cA-44v r 6 (-At r1 A -c- --t c� 604)4 v 4rxs�g.c.Afpi' Bort - &ID - 1155 cdci Cp nlAtn ja PPok rr ovrektkei. c4 trt4 3 aEr o 80 1 Inspector: /0( Date: 1A(01/17 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Project: V itt tZfef- Type of Inspection: Vi,C.,t' Address: X75"5- /31 6- . Date Called: Special Instructions: Date Wanted: �, i a m: 6/ `/j Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: .5Ko Inspector: \1:66\ii1J REINSPECTION FEE REQUIRED. prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 0,0,4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � /� , tType of Inspection: � A1 CX Address: IN -7,..--j i3yPt_ Date Called: Special Instructions: f Date Wanted: 6 i p 6 Requester: X Phone No: ,� J 2 324-3 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: FAv (6sKoefiD/Is 13s0)E . - Glk srh E Gort\I Inspector:( � Date: 1111 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPEQTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit P RMIT NO Project: A I /-..,,i /WU '' W-. Type of Inspection: (1 iCe Address: Liuj pi.,, Date Called: Special Inst u ions: Date Wanted: 6h a.m: P• Requester: ie.,. Phone No: a43 315 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4*- c,t) 6ia. 0 ki-QJ iLt3 -- LA-si4- laATE <Si►�F Inspector: Date: 43117 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD • INSPECTION NO. Retain a copy with permit 6u -1-(m RMI-( T NO. f CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ....--e-t Type of Inspection: sk. /ifel Address: s.6,/ k. Date Called: Special Instructions: Date Wanted: ` % ''7 /. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: L tJ G kievA) t1t - LoAp 7 Cr5 nif/� Do�n�si2M-' Inspector: //b4\letS REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: /97/ 2 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 647-0/y PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project:Type lam- of Inspection: .)if e6 Address: tiLlicrs (3Li k- Date Called: Instructions: Special6.):- Date Wanted: , 2,3 Requester: Phone No: 253 y57 2,11L ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 0 _11, , PA-Ako bist`,oaiJ i 1 i Cr Orixi 7 i\fo - O> i Z -G 4Q »JP Az( z( g D is D C Inspector: 1 Date: 5,123/ 7 REINSPECTION' FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD / I Retain a copy with permit ) — 0 INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION I'► 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: A\ifti.!: Type of Inspection: / I� Address: ,,,17‹ '�/ 3 p, . Date Called: Special Instructions: J 0 k iff® st Date Wanted:VoI a.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: o/ Inspector: Date: ©S701 17 REINSPECT! FEE REQUIRED. Prior to next inspection. fee knust be paid at 6300 outhcenter Blvd.. Suite 100. Call to schedute reinspection. OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: �p- z - / 1 Requested By: gei.col 9 n 7 . Firm/Company: iepgi C' 4c_440.4 Inspection Information Project Name: 'N U c.�+ Permit Number: ei �. / 70 /5 / Project Address/Location: 7 /3zt-h4 P/occs Requested Date for Inspection: e.0, /7 Contact Name: Special Conditions for Consideration: Requested Time: /0;00 -- /2. .'t7 /PM Phone Number: Z-(3 — 3 25'I"--- ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $102.00 per hour (minimum total of $306.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: Date: f Zv /1 Printed Name: C. /( )11i S City Use OnIy: Approved: 'lv Disapproved: Paid: 1,3( -OD Receipt No: gilivo Remarks:.J) m CVO' (f)12-° )1 Date of Approval/Disapproval: Authorized Reviewer: W:\Permit Center \Applications-Handouts\Templates\Forms\Off Hours Inspection 1-2017.docx Revised: January 1, 2017 ?EMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0154 DATE: 03/01/17 PROJECT NAME: AVURE TECHNOLOGIES SITE ADDRESS: 4475 S 134TH PL X Original Plan Submittal Response to Correction Letter #_ Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 3-9-11 Building Division Public Works ❑ Fire Prevention Structural n Planning Division ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 03/02/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) 03/30/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: f Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW ❑nci Staff Initials: tier, 12/18/2013 KIRBY ELECTRIC INC Borne Espanol Contact, Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L&I Workplace Rights Trades & Licensing KIRBY ELECTRIC INC Owner or tradesperson Principals KIRBY, DOUGLAS E, PRESIDENT Kirby, Douglas, AGENT KIRBY, SHANNON, AGENT (End: 01/04/2012) KIRBY, SHANON E, AGENT (End: 01/04/2012) Doing business as KIRBY ELECTRIC INC WA UBI No. 601 433 048 4826 B ST NW STE 101 AUBURN, WA 98001 253-859-2000 KING County Business type Corporation Governing persons DOUGLAS EDGAR KIRBY SHANON ELAINE KIRBY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. KIRBYEI077BN Effective — expiration 01/15/1993— 01/13/2019 Designated administrator KIRBY, DOUGLAS E Active. Meets current requirements. License type License no. Master Electrician KIRBYDE962LZ Bond WESTERN SURETY CO Bond account no. 70607132 $4,000.00 Received by L&I Effective date 11/05/2008 01/14/2009 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601433048&LIC=KIRBYEI077BN&SAW= 3/14/2017 KIRBY ELECTRIC INC Page 2 of 3 Infraction no. EROJE00253 Satisfied Issue date RCWIWAC 11/03/2014 19.28.101 RCW Violation city Violation amount AUBURN $1,000.00 Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EALLM00349 Issue date 06/30/2014 Violation city AUBURN Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296-468-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $500.00 Infraction no. EALLM00348 Issue date 06/30/2014 Violation city AUBURN Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Infraction no. EMURD00529 Issue date 02/07/2013 Violation city AUBURN Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296 -46B -900(10)(a), effective after 12/30/2008 see WAC 296 -46B -901(10)(a). Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Workers' comp Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601433048&LIC=KIRBYEI077BN&SAW= 3/14/2017 ELECTRICAL DRAWI ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kir Dyelectric.com GS SEPARATE PERMIT REQUIRED FOR: Ltd Mechanical 0 Electrical Rlumbing Cig' as Piping City of Tukwila BLIII_DING DIVISION REVISIONS No changes shall be made to the scope of work vvithout prior approval of Tukwila Building Division_ NOTE: Revisions will require a new plan submittal and may include addtianai plan review fees_ fl COPY ermit o. L- l j Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorise the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE OCNECTH MAR 10 2017 u%Q- City of .Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER SHEET INDEX PAGE: DESCRIPTION E0.0 COVER SHEET E1 .0 POWER PLAN RISER PAN SCHEDUL 7/227 ELECTRICInc. COMMERCIAL• INDUSTRIAL www.Wrbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 AVURC TECHNOLOGIES 4475 S. 134th PL, Seattle, WA 98168 REVISIONS: COVER SHEET SCALE: SEE PLAN DATE' 10-01-16 DRAWN BY: S.K. CHECKED BY: SHEET E0.0 JOB NO.: OF (1) SCALE: 1/4" = 1' 0" CONFERENCE ROOM OFFICE OFFICE OFFICE AREA OF WORK H -7,9,11 - RESTROOM L-32 HFP-1 SHOP KITCHEN RESTROOM VACUUM SEALER DISH ASHE ALLERGEN L-27 L-22 ULFRZ-1 L-20 L-39 L-25 L-15 MICRO BIOLOGY L-31 L-33 LF HOOD 1 INCU 4 L-24 1 1 1 1 1 1 1 1 1 2111121111 UZI= CM= =I =I =I 11:1=1 111101213 =121 L-17 REVIEWED FOR COFPA 7�c NEC�E TH N MAR 10 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL FEB 2 8 2017 PERMIT CENTER 7!,,', ELECTRIC1nc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "8" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 AVURC TECHNOLOGIES 4475 S. 134th PL, Seattle, WA 98168 REVISIONS: A POWER PLAN S L 11 0 1 S� PONER PLAN SCALE: SEE PLAN DATE:10-01-16 DRAWN BY: S.K. CHECKED BY: SHEET E1.0 JOB NO.: OF ELECTRICAL ROOM TI SPACE -1 E 7 EXISTING f -1 600A BUSS GUTTER / / TO UTILITY TRANSFORMER L_ J 0 3-1/2" W/(4)500AL 400A DISC. -(2) 2-1/2" W/(4)250AL 300A 277/ 480V PANEL H 1-1/2" - W/(3)#1AL 75KVA XFMR 200A 120/ 208V PANEL L Q J L 2-1/2" W/(4)#250AL L_ J L J PNL. H LOCATION: TI SPACE FED FROM: BUSS GUTTER MCB: AIC RATING: 277/480V 300A CKT NO. LOAD DESCRIPTION TRIP AMPS A B C TRIP AMPS LOAD DESCRIPTION CKT NO. 1 3 5 3 -TON HVAC 20 3504 3504 3504 3504 3504 3504 2 4 6 7 9 11 FOOD PROCESSOR 150 19200 19200 19200 19200 19200 19200 8 10 12 13 WAREHOUSE LIGHTING 20 3540 3540 14 15 16 17 1 18 19 1 20 21 1 22 23 1 24 25 26 27 t 28 29 30 31 32 33 34 35 36 37 39 41 8504 9524 6104 8504 9524 6104 90 75 kVA TRANSFORMER 38 40 42 TOTAL PHASE LOAD: TOTAL PANEL LOAD: REMARKS: PANEL AND LOADS EXISTING, ADDING A 3 PHASE BREAKER FOR NEW EQUIPMENT. 34748 32228 28808 95784 CONNECTED LOAD: DEMAND LOAD: 95.8KVA 115.3AMPS 104.0KVA 125.2AMPS ONE LINE RISER SCALE: N.T.S. REVIEWEDFOR COMPLIANCE WITH NFPA70-NEC MAR 1 0 2017 City ofTukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER Lt7 olSLl MRBY ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 AVURC TECHNOLOGIES 4475 S. 134th PL, Seattle, WA 98168 REVISIONS: SCALE: SEE PLAN DATE:10-01-16 DRAWN BY: S.K. CHECKED BY: SHEET JOB NO.: OF PNL. L LOCATION: TO SPACE FED FROM: PANEL H MCB: - 120/208V AIC RATING: - 200A CKT NO. LOAD DESCRIPTION TRIP AMPS A B C TRIP AMPS LOAD DESCRIPTION CKT NO. 1 OFFICE RECEPTACLES 20 1440 2340 900 20 UNIT HEATER 2 3 OFFICE RECEPTACLES 20 1440 3104 1664 30 HOT WATER TANK 4 5 BREAK ROOM DED. REFER 20 1500 3164 1664 6 7 BREAK ROOM DED. MICROWAVE 20 1500 3164 1664 8 9 RESTROOM DED. 20 1500 3420 1920 20 OFFICE LIGHTING 10 11 WAREHOUSE RECEPTACLES 20 1440 3240 1800 20 STOVE/OVEN 12 13 DED. FREEZER 20 1500 2100 600 20 VENT HOOD 14 15 ULTRA-LOW FREEZER 20 1500 2100 600 20 DISHWASHER 16 17 CHEST FREEZER 20 1500 2100 600 20 DISHWASHER 18 19 DED. REFER. 20 1500 2100 600 20 DISHWASHER 20 21 DED. REFER 20 1500 3300 1800 20 CENTRIFUGE 22 23 DED. REFER 20 1500 3300 1800 20 AIR COMPRESSOR 24 25 DED. REFER 20 1500 2100 600 20 AUTOCLAVE 26 27 PROTEIN INCUBATOR 20 1800 2400 600 20 AUTOCLAVE FUME HOOD 28 29 INCU-2 20 1800 2400 600 20 FUME HOOD 30 31 INCU-3 20 840 2640 1800 20 ICE MACHINE 32 33 INCU-4 20 840 1440 600 20 DEIONIZED WATER SYSTEM 34 35 KITCHEN RECEPTACLES 20 1440 1440 - - - 36 37 ALLERGEN RECEPTACLES 20 1440 1440 - - - 38 39 MICRO BIOLOGY RECEPTACLES 20 1440 1440- - - 40 41 - - - - - - 42 TOTAL PHASE LOAD: TOTAL PANEL LOAD: REMARKS: PANEL AND LOADS EXISTING, ADDED BRAKERS AND LOADS ARE BASED ON EQUIPMENT FROM E1.0. 15884 17204 15644 CONNECTED LOAD: 48.7KVA 135.4AMPS DEMAND LOAD: 32.2KVA 89.3AMPS 48732 REVIEWEDFOR COMPLIANCE WITH NFPA70-NEC MAR 1 0 2017 City ofTukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 8 2017 PERMIT CENTER Lt7 olSLl MRBY ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 101 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 AVURC TECHNOLOGIES 4475 S. 134th PL, Seattle, WA 98168 REVISIONS: SCALE: SEE PLAN DATE:10-01-16 DRAWN BY: S.K. CHECKED BY: SHEET JOB NO.: OF