Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL17-0308 - CASCADE VIEW ELEMENTARY - CAFETERIA EXPANSION AND MINOR ADMINISTRATION RECONFIGURATION
CASCADE VIEW ELEMENTARY 13601 32 AVE S ELI 7-0308 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 1623049038 Permit Number: 13601 32ND AVE S Project Name: CASCADE VIEW ELEMENTARY Issue Date: Permit Expires On: EL17-0308 6/29/2017 12/26/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 ALEXANDER CLARK AIA Phone: (206) 624-4222 105 SOUTH MAIN ST #323 , SEATTLE, WA, 98116 PACIFIC COAST ELECT CONTR INC Phone: (425) 741-2700 16620 NORTH ROAD, BOTHELL, WA, 98021-5908 PACIFICE077MA Expiration Date: 7/8/2019 DESCRIPTION OF WORK: PROVIDE POWER, LIGHTING AND SYSTEMS TO A 2257 SF CAFETERIA EXPANSION, AND MINOR ADMINISTRATION RECONFIGURATION. ELECTRICAL SUPPORT FOR REPLACING(8) MECHANICAL UNITS AND INSTALLATION OF ONE NEW MECHANICAL UNIT Valuation of single family: $0.00 Valuation of mf/comm: $237,475.00 Type of Work: Fees Collected: $4,624.04 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: NONE,VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: (gt)41 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: j Date: 6/2f/2-17Print Name: Math U VVI pC tof This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. ew-oto Project No. Date Application Accepted: 14 /'VI 11 Date Application Expires: 101 I 1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 13601 32ND AVE S TUKWILA WA 98168 Suite Number: Floor: Tenant Name: TUKWILA SCHOOL DISTRICT — CIA§CaOl ej WOW New Tenant: ❑ Yes ®..No PROPERTY OWNER Name: TUKWILA SCHOOL DISTRICT Address: 4640 S 144TH ST City: TUKWILA State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: , J U» 4ivp Z G4.4 Address: /e*-- S. M4-JiV qr. .5,ut7b 3 2,3 City: fr6../ 6 State: OA Zip:70 /09 Phone: 2t). 62Af tem Fax: Email: eit e_44, /,:OGitiiGtp"p„. r?1e eeot ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 233-/ X 7. Scope of Work (please provide detailed information): Provide power, lighting and systems to a 2,257 sf cafeteria expansion, and minor administration reconfiguration. Electrical support for replacing (8) mechanical units and installation of one new mechanical unit. Will service be altered? ❑ Yes No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ® Addition 0 Service Change ❑ Remodel m Tenant Improvement ❑ Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served bv: ❑ Puget Sound Energy ® Seattle City Light W:\Permit Ccntct\Applications-Handouts\Pcrmit Applications\PDF's\Electrical Permit Application Rcviscd 1-1-17.docx Rcviscd: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea • Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRIC NTRACTOR: Signature: Print Name: G 4't�k Mailing Address: 141,13A) Ef. 32-3 W:\Pcrmit Center\Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised 1-I-17.docx Revised: January 2017 bh Date: /e5/p.cf Day Telephone: *6 -621 - I g - 6 i� /(AM- ( State Zip City Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY : PAID $5,994.63 EL17-0308 Address: 13601 32ND AVE S Apn: 1623049038 $3,755.84 Credit Card Fee $109.39 Credit Card Fee 1 R000.369.908.00.00 0.00 $109.39 ELECTRICAL $3,472.81 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 I 0.00 $3,472.81 TECHNOLOGY FEE $173.64 TECHNOLOGY FEE 1 R000.322.900,04.00 I 0.00 $173.64 EL17-0309 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $1,763.29. Credit Card Fee $51.36 Credit Card Fee 1 R000,369,908.00.00 0.00 $51.36 ELECTRICAL $1,630.41 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 0.00 $1,630.41 TECHNOLOGY FEE $81.52 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 $81.52 EL17-0310 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $475.50 Credit Card Fee $13.85 Credit Card Fee 1 R000.369.908.00.00 I 0.00 $13.85 ELECTRICAL $439.67 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 0.00 $439.67 TECHNOLOGY FEE $21.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11830 R000.322.900.04.00 0.00 " $21.98 $5,994.63 Date Paid: Thursday, June 29, 2017 Paid By: RICK ROTHERMEL Pay Method: CREDIT CARD 049710 Printed: Thursday, June 29, 2017 1:32 PM 1 of 1 CiriWSYSTEMS Cash Register Receipt City of Tukwila Receipt Number R11350 DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $3,438.09 D17-0110 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $569.36 DEVELOPMENT $569.36 PERMIT FEE R000.322.100.00.00 0.00 $69.83 PLAN CHECK FEE R000.345.830.00.00 0.00 $499.53 EL17-0308 Address: 13601 32ND AVE S Apn: 1623049038 $868.20 ELECTRICAL $868.20 PLAN CHECK FEE R000.345.832.00.00 0.00 $868.20 EL17-0309 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $407.60 ELECTRICAL $407.60 PLAN CHECK FEE R000.345.832.00.00 0.00 $407.60 EL17-0310 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $109.92 ELECTRICAL $109.92 PLAN CHECK FEE I R000.345.832.00.00 I 0.00 $109.92 M17-0056 Address: 13601 32ND AVE S Apn: 1623049038 $846.95 MECHANICAL $846.95 PLAN CHECK FEE R000.322.102.00.00 0.00 I $846.95 M17-0057 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $462.66 MECHANICAL $462.66 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 I $462.66 M17-0058 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $63.61 MECHANICAL $63.61 PLAN CHECK FEE R000.322.102.00.00 0.00 I $63.61 PG17-0048 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $109.79 PLUMBING $109.79 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R11350 0.00 $109.79 $3,438.09 Date Paid: Tuesday, April 25, 2017 Paid By: TUKWILA SCHOOL DISTRICT Pay Method: CHECK 95046 Printed: Tuesday, April 25, 2017 12:59 PM 1 of 1 CSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:cM e 0161,3 Type of Inspection: 6, �' C Address.! 3&0/ 3 ! Date Called: I Instructions: Date Wanted: A0rg6 1/Special l Requester: Phone No: (0 671 �� 372 gjApproved per applicable codes. 1 Corrections required prior to approval. COMMENTS: 0-v\if Nike/ N Inspector: A-11/ Ce4161\ REINSPECTION EE REQUIRED. Prior to next inspection. fee must bel' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPE TION N0. 6,17-034 PURMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ASCikt)ttilej Type of Inspectiopf`/ c)4 t / (`�Project:(/{ Address:: /3,®1 31- 4 / Date Called: Special Instructions: Date Wanted: j /� Requester: Phone No: °6' 671i337L- Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: /Fr 64(6 l - 61! S _cPrFl4, 1-Fe-irr Poie 60l -r <01c, tztLe_ Zt� I /17 REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: Date: 61712 INSPECTION RECORD.43ARetain a copy with permit ti4/ 7 INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: C/I'isc, 'toe vila-vi Type of Inspection: WOO- id Address:/ ,6 3 /r2 Special Ins ructions: r'JL,1CV Date Called: Date Wanted: Requester: Approved per applicable codes. Corrections required prior to approval. COMMENTS: CACCIVZ-Ak Pero"/ rAt-irPF-kei- jso7 Inspector:ti.°--''' cAlfled Date: 0 71 1 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6.1 L Type of Inspection: 0 (A Address: /3&o/ 31 X14 Date Called: Special Instructions: Date Wanted: n il Z••••- a.m. Requester: ,, /� rJi'co! Phone No: go Cl 3 ( I— Approved per applicable codes. Corrections required prior to approval. COMMENTS: i4A4 LID 1-&ek J6Si v6sTi m l.1 u1/414 -K-5 Higki, Inspector: 6,k) Date: ate: 071417 REINSPECTIO FEE REQUIRED: Prior to next inspection, .fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit611 IL INSPE ION NO. PJOO MITNO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6� C IQe 'v/ Approved X Type of it Date Called: 7 /'J tF�,t .... Address. /360/3Z_4� Special Instructions: ,Cv ?Arc_ ks r �'(,,1, v r Date Wanted: O 33 a.m S Requester: Phone No: No 0i3372 i3372— XApproved per applicable codes. 0Corrections required prior to approval. COMMENTS: L '• -�' SUV ��f�j Xiiiii Pi+ .. k. / o oetAily ® - rJJs-f7 is l), aPlc& t (lclL To`c1 AA4b `�'\ StAli i"- �S 1, R v l .- Inspector: j Date: o43o (7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE MIT NO. elA -03a CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Cr5 M4`, , Type of Inspection: 1.1)"4 j Address: Date Called: Special Instructions: Date Wanted:. 8/ 02-- a.m. p.m. Requester: Phone No: 61 V SY7 Lo I, ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: \Ar l'\ . - yeo iuk-6.E t.JM..', Inspector: Date: �y Q7/C`O1/ t ri REINSPECT! FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 outhcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: eits f 6J Td of I section OV tI4 CI Address: ei 0(90i 32 AV' Date Called: Special Instructions: Date Wanted: 7p.m. air Requester: Phone No: LJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: P X(P±1 S\ 61bJr ,d Odpr'( Covre-0\ A -SS Kau(' OFF-t,c Inspector: r•16 Date: 01/24 1 REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P RMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43113670 Permit Inspection RequestLine (206) 438-9350 Project: o/360/32,� T6j,/eofInsPectIon: do � Oe Called: 1 Special Instructions: Date Wanted: M !I p.m. Requester: Phone No: 1 7 ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: fA -A, - 6,a69\447A doAlbdi 'Ai PO kAlprZ3 hLbti 1 Insp ettnr: (..j7- 1 117 REINSPECT! ,N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: PERMIT COORD COP" PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0308 DATE: 04/28/17 PROJECT NAME: CASCADE VIEW ELEMENTARY SITE ADDRESS: 13601 32ND AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: mac, 5;4,17 Building Division Public Works 5111 Fire Prevention ❑ Planning Division Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 05/02/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 05/30/17 ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PACIFIC COAST ELECT CONTR I' Home. Espanol Contact Safety & Health Claims & Insurance Washington State Department of ‘,4 Labor & Industries Search L&I Page 1 of 2 Mural A -Z Index Help My Lex] Workplace Rights Trades & Licensing PACIFIC COAST ELECT CONTR INC Owner or tradesperson Principals BLACKBURN, R DAVID, PRESIDENT ROTHERMEL, RICK A, VICE PRESIDENT BLACKBURN, R DAVID, AGENT Doing business as PACIFIC COAST ELECT CONTR INC WA UBI No. 601 473 603 16620 NORTH ROAD BOTHELL, WA 98012-5908 425-741-2700 SNOHOMISH County Business type Corporation Governing persons DALE M CAMPBELL R DAVID BLACKBURN; RICK ROTHERMEL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. PACIFCE077MA Effective — expiration 07/01/1993— 07/08/2019 Designated administrator BLACKBURN, RALPH DAVID License type Electrical Administrator Bond ........... 01-110 CAS INS CO Bond account no. 3342328 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. Active. Meets current requirements. License no. BLACKRD066CE $4,000.00 Effective date 07/02/1996 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601473603&LIC=PACIFCE077MA&SAW= 6/29/2017 PACIFIC COAST ELECT CONTR INC Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 848,659-00 ................................. Doing business as PACIFIC COAST ELECTRICAL CONTR Estimated workers reported Quarter 1 of Year 2017 "31 to 50 Workers" L&I account contact Employer Services Help Line — 360-902-4817 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/15/2013 Inspection no. 316625920 Location 12401 SE 320th St Auburn, WA 98092 No violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601473603&LIC=PACIFCE077MA&SAW= 6/29/2017 ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION LIGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. SPECIAL EQUIP CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT MOTOR CONNECTION CONDUIT EXPOSED CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY CONDUIT UNDER GROUND OR FLOOR EXISTING CONDUIT NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION FUSED DISCONNECT/MAGNETIC STARTER MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION CONDUIT UP 0 ELECTRICAL CONTACTOR, TYPE AS INDICATED J CONDUIT DOWN CONDUIT STUB OUT WITH PLASTIC BUSHING BRANCH CIRCUIT HOME RUN GROUNDING ELECTRODE PER CODES 4 FAP SINGLE PUSH BUTTON PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER RED EMERGENCY SHUT-OFF PUSH BUTTON FIRE ALARM PANEL dbA tl!! FLEXIBLE CONDUIT CODE SIZED JUNCTION BOX WITH COVER PLATE CORD REEL WITH 4PLEX OUTLET CEILING RECEPTACLE ELECTRICAL DEVICE AS INDICATED, A=ABOVE COUNTER DUPLEX RECEPTACLE DUPLEX RECEPTACLE, TAMPER RESISTANT TYPE TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE, TAMPER RESISTANT TYPE_ TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE SINGLE RECEPTACLE 0 FIRE ALARM ANNUNCIATOR FIRE ALARM SMOKE DETECTOR FIRE ALARM SMOKE DETECTOR, DUCT TYPE FIRE ALARM HEAT DETECTOR, RATE -OF -RISE TYPE FIRE ALARM HEAT DETECTOR, FIXED TEMPERATURE TYPE FIRE ALARM SMOKE DETECTOR, PROJECTION BEAM TYPE BEAM DETECTOR CONTROL UNIT FIRE ALARM CONNECTION, TYPE AS NOTED ON PLANS TAMPER SWITCH FIRE ALARM MONITORING CONNECTION FLOW SWITCH FIRE ALARM MONITORING CONNECTION \'J STAGE LIGHTING CONTROL RECEPTACLE FLUSH FLOOR BOX WITH DEVICES AS INDICATED DUPLEX RECEPTACLE GFCI TYPE DUPLEX RECEPTACLE SURGE PROTECTION TYPE A a FIRE ALARM AUDIO-VISUAL HORN/STROBE FIRE ALARM STROBE LIGHT FIRE ALARM MANUAL PULL STATION, D=DUAL ACTION TYPE. FIRE ALARM DOOR RELEASE CONNECTION LI4:% dVd SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS MULTI -GANG FLOOR BOX WITH DEVICES AS NOTED ON PLANS WITH 1"C.O. SPARE.._TOADJACENT CEILING.,_SPACE...___ _-..__._..._..___ ____._..__......._......._ _...__.__ SURFACE METAL RACEWAY WITH DEVICES AS INDICATED. PROVIDE COMPLETE DEVICES, FITTINGS AND ASSEMBLIES. OC. SPACING OF DEVICES ARE AS NOTED ON PLANS. LIGHT FIXTURE, SEE SCHEDULE FOR TYPE FIRE ALARM COMBINATION FIRE/SMOKE DAMPER CEILING MOUNT FIRE ALARM AUDIO-VISUAL SPEAKER/STROBE BELL/BUZZER SECURITY SYSTEM MOTION DETECTOR SECURITY SYSTEM CEILING MOUNT MOTION DETECTOR 360'. EL 0 'EL'BATTERY PACK LIGHT FIXTURE, WITHINDICATES.WITH EMERGENCY LIGHT FIXTURE, SEE SCHEDULE FOR TYPE WALL MOUNTED LIGHT FIXTURE, SEESCHEDULE FOR TYPE LIGHT FIXTURE, SEE SCHEDULE FOR TYPE SECURITY SYSTEM MAGNETIC CONTACT SECURITY SYSTEM KEY PAD SECURITY SYSTEM CARD READER REQUEST TO EXIT SENSOR SECURITY SYSTEM CAMERA LOCATION EXIT LIGHT WITH EMERGENCY DRIVER TYPICAL LIGHTING FIXTURE DESIGNATION, SEE SCHEDULE FOR TYPE SINGLE POLE SWITCH THREE WAY SWITCH LOW VOLTAGE SWITCH MOMENTARY CONTACT SWITCH PILOT LIGHTED SWITCH KEY OPERATED SWITCH MANUAL DIMMER SWITCH v ADM V 0 MC 0 LOCK DOWN BUTTON (SECURITY/INTERCOM CONNECTIONS) INTERCOM CONSOLE INTERCOM DIGITAL DISPLAY INTERCOM CALL SWITCH INTERCOM HANDSET, ADM=ADMIN TYPE WITH DISPLAY D=DESK TYPE INTERCOM WALL OR CEILING SPEAKER INTERCOM WEATHERPROOF OUTDOOR HORN/SPEAKER MASTER CLOCK ANALOG CLOCK Oc WALL MOUNT OCCUPANCY SENSOR SWITCH CEILING MOUNTED PHOTO CELL/PHOTO SENSOR LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (WALL MOUNT) LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (CEILING MOUNT) LIGHTING ROOM CONTROLLER DIGITAL CLOCK ANALOG CLOCK/SPEAKER COMBINATION DIGITAL CLOCK/SPEAKER COMBINATION VOLUME CONTROL VIDEO PROJECTOR OUTLET ►4 SWITCHED RECEPTACLE CONTROLLER THERMOSTAT SOLENOID VALVE AQUASTAT BY MC, CONNECTIONS TO CIRC PUMP BY EC TELECOMMUNICATIONS - OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) i = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (I.E. 1,2,3, ETC.) WAP ADJACENT TO SYMBOL = WIRELESS ACCESS POINT TELECOM CONNECTION TELECOMMUNICATIONS - FLOOR OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) f = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (I.E. 1,2,3, ETC.) AMP SOUND SYSTEM AMPLIFIER SOUND SYSTEM. SPEAKER MICROPHONE JACK SOUND SYSTEM AUXILIARY INPUT TV OUTLET TELEVISION AUDIO-VISUAL INPUT JACK PRIMARY DAYLIGHT ZONE, SECONDARY DAYLIGHT ZONE, TOPLIGHT DAYLIGHT ZONE AS REQUIRED BY WASHINGTON STATE ENERGY CODE. (SEE LIGHTING PLANS) AVL HDML AV OUTLET (LOW) ADJACENT TELECOM OUTLET HDMI GROMMET PLATE (HIGH) ADJACENT WALL PROJECTOR Ms MASTER STATION VIDEO INTERCOM VIDEO DOOR STATION SEPARATE PERMIT REQUIRED FOR: Mechanical 0 3ieCttiGr'11 /,Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No ch a n aesshz r! 1 be made to the scope of work without prior approval of Tukwila Building Division. TOTE: Revisions will require a new plan submittal and may include additional plan review fees. ermit ..E16-110224 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fk Id Copy and conditions is acknowledged: By: Date: 2 2.0 City of Tukwila UILDING DIVISION A E3REVI4TION (4V) AB13RV DESCRIPTION ABBRV DESCRIPTION AFF AL ABOVE FINISHED FLOOR ALUMINUM LTG M.C. LIGHTING MECHANICAL CONTRACTOR BB BASEBOARD HEATER MLO MAIN LUG ONLY BKR C CKT C.O. COMM BREAKER CONDUIT CIRCUIT CONDUIT AND PULL WIRE ONLY COMMUNICATION MH OL PNL RH SB Cu E.C. EF EQP FA COPPER ELECTRICAL CONTRACTOR EXHAUST FAN EQUIPMENT FIRE ALARM G.C. GENERAL CONTRACTOR GFI IDF MDF DH MDP GROUND FAULT INTERRUPTER INTERMEDIATE DISTRIBUTION FRAME MAIN _...__.._.__.__._ ...._........._._.... MAIN DISTRIBUTION FRAME DUCT HEATER MAIN DISTRIBUTION PANEL SC SDP SPECS SW TEL TEM P THRU TV TYP WG WP METAL HALIDE OVER LOAD PANEL RANGE HOOD SCORE BOARD SHOT CLOCK SECONDARY DISTRIBUTION PNL SPECIFICATIONS SWITCH TELEPHONE TEMPERATURE THROUGH TELEVISION TYPICAL WIRE GUARD WEATHER PROOF LCC LIGHTING CONTROL CENTER XFMR TRANSFORMER A PL IANCES KEY LETTER E.C. TO PROVIDE RECEPTACLE FOR APPLIANCE AS SHOWN. VERIFY LOCATION WITH ARCHITECT. CM : COFFEE MAKER CP : COPIER DW : DISHWASHER DY : DRYER FZR : FREEZER GD : GARBAGE DISPOSAL. H/HD : HAND OR HAIR DRYER IH : INSTANT HOT WATER HEATER IM ICE MAKER MW : MICROWAVE REF : REFRIGERATOR VM : VENDING MACHINE WH :WASHER ELECTRICAL SI-IEET L IST CE0.01 CE0.02 ELECTRICAL LEGEND, SCHEDULES AND NOTES WSEC FORM • CE1.01 CED1.01 CE2.01 ELECTRICAL SITE PLAN BUILDINGS A & B - LIGHTING DEMOLITION BUILDINGS A & B - POWER CE2.02 CE2.03 CE2.04 BUILDING C - POWER BUILDING D - POWER BUILDING E - POWER CE3.01 CE3.02 CE3.03 CE3.04 BUILDINGS A & B - SYSTEMS BUILDING C - SYSTEMS BUILDING D SYSTEMS BUILDING E SYSTEMS CE4.01 CE4.02 CE4.03 BUILDINGS A & B - MECHANICAL ROOM & ROOF PLAN BUILDING C - MECHANICAL ROOM & ROOF PLAN BUILDING D - MECHANICAL ROOM & ROOF PLAN CE4.04 CE5.01 CE5.02 BUILDING E - MECHANICAL ROOM & ROOF PLAN POWER ONE -LINE DIAGRAM PANEL SCHEDULES CE5.03 CE5.04 CE7.01 CE8.01 CE8.02 CE8.03 PANEL SCHEDULES PANEL SCHEDULES BUILDINGS A & B - LIGHTING SYSTEMS ONE -LINE & DETAILS SYSTEMS ONE -LINE & DETAILS LIGHTING/RECEPTACLE CONTROL DIAGRAMS GENERAL REQUIREMENTS ALL SLEETS 1. E.C. TO PROVIDE ALL MATERIAL AND LABOR FOR MAINTAINING FIRE RATING OF WALLS IN AREAS WHERE ELECTRICAL DEVICES PENETRATE IN OR THROUGH. SEE ARCHITECTURAL DRAWING FOR FIRE WALL LOCATION. 2. E.C. TO PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES. COORDINATE LOCATION AND CONNECTIONS WITH M.C. 3. SEE ARCHITECTURAL DRAWING FOR LOCATION OF ELECTRICAL DEVICES LOCATED ON EXTERIOR OF BUILDING. ALL EXTERIOR BUILDING MOUNTED DEVICES (EXCEPT FIRE ALARM DEVICES) SHALL HAVE FACTORY FINISH OR PAINT TO MATCH BUILDING. SURFACE. 4. ALL FLUSH MOUNT EQUIPMENT, CABINET AND PANEL BOARD SHALL HAVE FACTORY TYPE FLUSH MOUNT TRIM KIT FOR COMPLETE INSTALLATION. 5. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALTERNATE BID NUMBERS AND CORRESPONDING AREAS AND RELATED ELECTRICAL WORK TO BE PROVIDED. E.C. TO INCLUDE IN BASE BID, ALL ELECTRICAL WORK THAT IS REQUIRED FOR BASE BID AND IN THE ASSOCIATED AREAS OF CONSTRUCTION IF ANY OF THE ALTERNATE BIDS ARE TAKEN OR ACCEPTED. 6. REFER TO PLANS FOR LOCATION OF EMERGENCY LIGHTING BATTERY PACK AND FIXTURES. 7. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND. 8. E.C. TO VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS AND COUNTER HEIGHTS PRIOR TO OUTLET ROUGH -IN. OUTLETS LOCATED ABOVE COUNTER ARE TO BE INSTALLED TO CENTER LINE ABOVE COUNTER TOP OF BACK SPLASH. AS DIRECTED OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH ARCH/ENG. OF ANY LOCATION THAT WILL NOT ACCOMMODATE MOUNTING HEIGHT. ALL EXTERIOR EQUIPMENT, PANELS OR DEVICES SHALL BE WEATHERPROOF AND WITH NEMA -3R ENCLOSURE TYPE. 10. ELECTRICAL CONTRACTOR TO VERIFY WITH SERVING UTILITY COMPANIES FOR ALL UTILITY CHARGES AND TO INCLUDE SUCH CHARGES IN BID. 11. CIRCUITS, WIRE SIZE AND WIRE HASH MARKS ARE SHOWN FOR CIRCUIT CLARITY, BUT MAY NOT NECESSARILY REPRESENT THE COMPLETE WIRING COUNTS AND MINIMUM SIZES FOR CONNECTING THE CIRCUITS SHOWN. E.C. TO INCLUDE IN THE BID, ALL THE REQUIRED WIRING SIZES AND NUMBER OF CONDUCTORS IN ORDER TO INSTALL ALL CIRCUITS SHOWN AS' NECESSARY. 12. ALL LIGHT SWITCHES SHALL BE LOCATED AT STRIKE SIDE OF DOOR SWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR DOOR LOCATIONS. SWITCHES THAT CAN NOT BE LOCATED ON STRIKE SIDE OF DOOR BECAUSE OF STRUCTURAL MEMBERS SHALL BE AS DIRECTED IN FIELD. 13. DO NOT INSTALL ANY FLUSH WALL OUTLET BACK TO BACK. A MINIMUM OF 24" SEPARATION IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL. 14. INSTALLATION OF NEW UNDERGROUND FEEDERS SERVING POWER, INTERCOM, TELEPHONE, FIRE ALARM, AND T.V. SHALL INCLUDE CUTTING, PATCHING, HAND DIGGING, ETC. DO NOT CUT OR DAMAGE ANY EXISTING UTILITIES, STRUCTURAL MEMBERS OR BUILDING FOUNDATIONS. VERIFY ROUTE AND REMOVE ALL EXISTING FLOOR TILE IN AREAS THAT ARE TO BE CUT. ANY DAMAGE TO EXISTING UTILITIES OR BUILDING STRUCTURE SHALL BE REPAIRED TO OWNER'S SATISFACTION AT THE CONTRACTORS EXPENSE. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO WORK. 15. ALL ONE LINES, RISERS, AND CONDUIT ROUTING ARE SCHEMATICS AND ARE NOT SHOWING EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT. WHERE INDICATED ON DRAWINGS ALL JUNCTION BOXES AND PULL BOXES ARE MINIMUM REQUIREMENTS. ELECTRICAL CONTRACTOR TO PROVIDE ALL OTHER FITTINGS AND PULL BOXES OF ADEQUATE SIZE IN THE RACEWAY SYSTEM WHEREVER NECESSARY OR REQUIRED BY NATIONAL ELECTRICAL. CODE. PROVIDE EXPANSION JOINT FITTINGS FOR CONDUITS PASSING THROUGH NEW INSTALLED BETWEEN BUILDINGS. VERIFY OR EXISTING EXPANSION JOINTSS NTA F EX EXACT LOCATIONS AND DETAILS O ANSION JOINTS PRIOR TO WORK. P COORDINATE ALL CONDUIT ROUTING, PULL BOX AND EQUIPMENT LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. 16. E.C. TO PROVIDE 60 WATT LAMPS FOR ALL RANGE HOODS. 17. NO ELECTRICAL CONDUITS ARE ALLOWED TO BE RUN IN ANY FLOOR SLABS. CONDUITS SERVING DEVICE LOCATED IN FLOOR SHALL BE SERVED FROM BELOW AND PASS THROUGH THE FLOOR SLAB. GENERAL NOTES IN AREAS WHERE ROOF STRUCTURE/DECKING IS EXPOSED E.C. SHALL PROVIDE ALTERNATE MEANS FOR DEVICE ATTACHMENT. E.C. SHALL PROVIDE UNISTRUT OR OTHER APPROVED METHODS FOR ATTACHMENT BETWEEN TRUSSES OR BEAMS. IN NO CASE SHALL ANY DEVICE BE MOUNTED ON THE EXPOSED UNDERSIDE OF THE ROOF DECK WITHOUT PRIOR APPROVAL FROM THE ARCH/MANUFACTURER. ALL SUPPORT ITEMS SHALL BE PAINTED TO MATCH SURROUNDING SURFACE. ALL MEANS OF SUPPORT/ATTACHMENT SHALL BE APPROVED BY THE ARCH. REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC MAY 2 6 2017 City of Tukwila LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER LAMP INPUT WATTS Notes RECEIVED NAME CATALOG NUMBER QTY. TYPE EBI 12"X28" CEILING MOUNT LUMINAIRE LED VPF122 50W 4000K 120-277 CP BLK EMB722C INC. LED 55 CITY OF TUKV'JI EXTERIOR BUILDING CANOPY APR 7 5 201? EB2 12"X38" CEILING MOUNT LUMINAIRE LED VPF123 125W 4000K 120-277 CP BLK EMB722C INC. LED 123 EXTERIOR BUILDING CAlifYIT CENTT P1 8"X4' DIRECT/INDIRECT CABLE HUNG LUMENWERX REVPICL PMO LED 80 740 500 40 LENGTH UNV D5 1 EB CABLE W INC. LED 64 CAFETERIA EXPANSION RI 6" LED DOWNLIGHT PRESCOLITE LF6LEDG4 6LFLED5G4 40K WT INC. LED 15 CAFETERIA EXPANSION R2 24"X48" RECESSED FROSTED LENS LUMENWERX NOVRS 24 PMO HLO LED 80 4000 40 UNV D5 TBAR W INC. LED 37 OFFICE X EXIT SIGN WALL MOUNT DUAL -LITE EVE U G W E I (WGLX WIRE GUARD, WHERE NOTED ON DWG) INC. LED 1 THROUGHOUT GENERAL NOTES: ALL FIXTURES WITHIN DAYLIGHT ZONES REQUIRE 0-10V DIMMING CAPABILITIES. Ae A rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226' Vv TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com w z 0 co (0 a) REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL LEGEND, SCHED. AND NOTES Drawing Number CE0.01_ELECTRICAL LEGEND.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCL ryOC "a he?.>sc kt".� lts'L Srzt ;rrt{"rw {th oz,11 randaElectrical r..tyts4 LTG -CHK G H erm I�tChecklistPg .3 Mo Permit Lightisn gMotor 'sJf 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and dl R1 Revised August 2016 Project Title: Cascade View Elementary School Renovations (Date 2/13/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component I Compliance information required in permit documents I Location in Documents I Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; CE0.01 C405.2 lighting Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Indicate on plans all fixtures provided with LLLC in lieu of C405.2 controls; provide description of control capabilities and performance parameters Office Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; NA 0405.1 Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently For permanently installed lighting fixtures in dwelling units, lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Type X, LED Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) CE7.01 CE7.01 NA C405.1 Lighting in dwelling units lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls CE7.01 NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; CE7.01 Lighting Power Calculation - Indicate compliance path taken Yes C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans CE0.02 NA C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable 2282 Yes NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance fomes that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method NA EXTERIOR LIGHTING POWER & EFFICACY Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; CE0.01 C405.2.6 Yes C405.5.2 Total connected exterior lighting power Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; NA 0405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Yes Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ CE0.02 NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule Yes 0405.2.4.2 C405.2.4.3 Yes Lighting in C405.5.2 Mtorand g� o Exterior lighting power calculations r . ,.':sC+Av, � , jElectrical Complete required compliance form — proposed wattage exterior lighting plus base site allowed does not exceed maximum allowed „L ., Permit Checklist .rv{ for . }; r.4 a P CE0.02 ..� 4 LTG CHK rr. Revised August 2016 2015 Washington State Energy Code Compliance Forams for Commercial Buildings including R2, R3, R4 over 3 stories and all Rl Project Title: Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Cascade View Elementary School Renovations Date 2/13/2017 The following Washington information is State Energy Code, necessary to check a Commercial Provisions. permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken CE5.1, Spec's Display and accent lighting NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter Yes C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied CE5.1 Motor o, NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; 2015 Washington State Energy Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more Project Title: NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use The following Washington information is State Energy Code, NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive Code Section Component Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; CE2.01, Spec's Hotel/motel guest rooms • Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control CE2.01, CE8.03 If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist M"„ iz <dU✓,., t; ;4 Y,.. '+ C tM1{,yf 104"' Y £1 Lighting Motor and 2015 Washington State EnergyCode Compliance Forms 9P (%R 4 3 S :y:l Cf�fi ti;; F'f "Y?Y` &f'. `2 1,,, { N!" ,Sk. 3 ,t, h ect ca LPermit heckIist;P . 1 LT =CHK�;.. for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Cascade View Elementary School Renovations (Date 2/13/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component (Compliance information required in permit documents I Location in Documents Building Department Notes LIGHTING CONTROLS Yes 0405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken CE7.01 CE7.01 NA C405.2 lighting Luminaire level controls lighting (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 controls; provide description of control capabilities and performance parameters Office CE7.01 NA 0405.1 Lighting in dwelling indicate units For permanently installed lighting fixtures in dwelling units, lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Type X, LED 4 Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405./5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves CE7.01 Yes C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls CE7.01 779 Method of automatic Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; CE7.01 Yes 0405.2.2 shut-off control Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies • CE7.01 Indicate on plans the spaces served by occupancy sensors; CE7.01 2282 Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception SPECIFICATIONS NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used NA 0405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; CE7.01 Daylight Indicate toplight daylight zone areas on plans, include sq. ft.; CE7.01 Yes 0405.2.4.2 C405.2.4.3 zones - Sidelight and toplight For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) Indicate on plans lighting zone(s) served by daylight responsive controls; CE7.01 Daylight responsive Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Yea 0405.2.4 controlsIndicateonplans the lighting load reduction method - g g continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power SPECIFICATIONS Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone SPECIFICATIONS NA C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section NA C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting Motor o, and :Permit'Checklist w Pg2 - LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 20'5 Project Title: Cascade View Elementary School Renovations Date 2/13/2017 The following Washington information is State Energy Code, necessary to check a Commercial Provisions. permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 Item 3 Hotel/motel guest rooms • Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room . NA C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; NA C405.2.5 Item 5 Lighting for non visual applications Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; demonstration Indicate method of manual lighting control and applicable automatic lighting control Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; CE7.01 C405.2.5 - Means of egress Provide calculation of lighting power density of total egress lighting; Yes Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served;. CE7.01 Yes C405.2.7 Exterior lighting For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawnldusk and fixed opening/closing time; controls For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or, are controlled by motion sensor, or are exempt lighting per C405.5.2 NA C405.2.5 Area controls - Master control Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; switches and circuit power limit Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% Enhanced digital To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; NA 0406.4 lighting controls Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) If claiming lighting system commissioning exemption provide supporting calculation; Yes C405.13 Lighting system Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; SPECIFICATIONS C408.3 functional testing Provide written procedures for functional testing of all automatic controls and describe the expected system response Interior' Y htln 1 Bu11d n Area Me LTG -INT -BLD 2015 Washington State Enercy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Cascade View Elementary School Renovations Date 2/13/2017 CalculationAddition Area NOmE 6 - Addition0 C1 New Construction Q stand alone + existing Clear Spaces where < 50% of ,--% Spaces where z 50% of o Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) For Building Department Use LPA Calculation Type Additional Efficiency Package Option 0 Standard 0 Clear C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage°7E 1 Building Area Location (plan#, room #, or ALL) Area Description Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) School/university CE7.01 Cafeteria Expansion B113 2161 0.70 1513 Office CE7.01 Office A113a 121 0.66 80 Type X, LED 4 1 4 Total Allowed Tradable + Site Allowance Watts: 779 Total 2282 Provosed Lightint; Wattage Building Area Location (plan #, room #) Fixture Description NOTE 2, 3, 4, 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed School/university CE7.01 Type P1, LED, 0-10V electronic dimming driver 22 64 1408 School/university CE7.01 Type R1, LED, 0-10V electronic dimming driver 4 15 60 Office CE7.01 Type R2, LED, 0-10V electronic dimming driver 2 37 74 School/university CE7.01 Type X, LED 4 1 4 Total Allowed Tradable + Site Allowance Watts: 779 Compliance by Building Area NOTE 7 Building Area Wamings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance School/university New construction © Addition - 0 Addition stand alone + existing O Alteration with < 50% o Alteration with z 50% ext. ext. wattage replaced wattage replaced 0 Clear 1513 1472 COMPLIES Office Type EB2, LED, 0-10V electronic dimming driver 80 74 COMPLIES Tradable Maximum Allowed Lighting Wattage NO1E 1 Base Site Allowance: 600 Tradable Surfaces Surface Description Area (ft2), perimeter (10 or # of items Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the project scope. Select building area category from drop down menu. Note 2 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 3 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 4 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 5 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer'slisted maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transforrner. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 7 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. Note 8 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing builidng lighting systems, include all applicable existing Building Area types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, use LTG -INT -SPACE form to document compliance. Totals 1593 1546 Exterior Lighting LTG EXT 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Cascade View Elementary School Renovations Date 2/13/2017 Exterior Lighting Zone Table C405.5.2(1) Specified by jurisdiction. 0 Zone 1 Q Zone 2 0 Zone 3 ()Zone 4 0 Clear Zone selection required to enable LTG -EXT form For Building Department Use - Calculation Area0 New construction © Addition - 0 Addition stand alone + existing O Alteration with < 50% o Alteration with z 50% ext. ext. wattage replaced wattage replaced 0 Clear Building Grounds Applies to luminaires > 100 Watts 55 385 • Efficacy > 80 lumens/watt • Exemptio Type EB2, LED, 0-10V electronic dimming driver 2 ■ Controlled by motion sensor 246 Tradable Maximum Allowed Lighting Wattage NO1E 1 Base Site Allowance: 600 Tradable Surfaces Surface Description Area (ft2), perimeter (10 or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) Grounds Walkways >10'wide Unconditioned Enclosure/Opened Entryway 1272 0.14 W/ft2 178 Total Allowed Tradable + Site Allowance Watts: 779 Tradable Proposed Lighting Wattage NOTE 2 Tradable Surface NOTE 3, 4 Fixture Description Number of Fixtures Watts per NOTE 5 Fixture Watts Proposed Grounds Walkways >10'wide Type EB1, LED, 0-10V electronic dimming driver 7 55 385 Grounds Walkways >10'wide Type EB2, LED, 0-10V electronic dimming driver 2 123 246 Exterior Lighting System Description Briefly describe exterior lighting system type and features. Remove existing 70W MH fixtures and replace with new LED fixtures. Existing exterior circuit controlled via building management system controls. Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: ,mute nine the, time= iiia nllnrnnranro Ani haeo kilo allninianna not nooflorl in maks 631 • tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage NOTE 1 Site Allowance Remaining: 600 Non -Tradable Surfaces Surface Description Area (12), perimeter (1f) or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x 10 Interior Lighting Controls in All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with th required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: 0 No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units Q C406.3 High Efficacy Lighting O R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Briefly describe exterior lighting system type and features. Remove existing 70W MH fixtures and replace with new LED fixtures. Existing exterior circuit controlled via building management system controls. Non -Tradable Proposed Lighting Wattage "OTE 2 Non Tradable Surface Fixture Description NOTE 3, a Number of Fixtures Watts per NOTE 5 Fixture Watts Proposed p Building Area Method ■ Space -by -space Method Select method used in project. Interior Lighting Controls in All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with th required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: 0 No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units Q C406.3 High Efficacy Lighting O R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Briefly describe exterior lighting system type and features. Remove existing 70W MH fixtures and replace with new LED fixtures. Existing exterior circuit controlled via building management system controls. Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces am less than the remaining site allowance. Non -Tradable Watts Exceeding LPA: Remaining Site Allowance: 0 600 Exterior Lighting COMPLIES WITH MAX. ALLOWANCE Note 1- List all unique exterior sufaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop down menu. Note 2 - List all proposed lighting fixtures including existing -to -remain fixtures. Note 3 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable). Note 4 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage fables in the same manner as new fixtures. Identify as existing in fixture description. Note 5 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. Lighting=' Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 20t Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: Cascade View Elementary School Renovations Date 2/13/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Company Name: Tres West Engineers, Inc. Company Address: 2702 South 42nd Street, Suite 301 Tacoma WA 98409 Applicant Name: David P Henning Applicant Phone: (253) 472-3300 Applicant Email: dph@treswestcom For Building Department Use Project Description ❑ New Building (] Addition II Alteration Include PROJ-SUM foram (included in envelope forms workbook) with lighting complliance forms. ❑,. Plans Included Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures am replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spacesundergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. ❑ No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced Less than 50% of existing are replaced Lamp and/or ballast replacement only — existing total wattage not increased 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel Interior space. is reconfigured - luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Lighting tiri Summar cont. g 9 Ya LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2013 Project Title: 1Date Cascade View ElementarySchool Renovations 2/13/2017 Interior Lighting System Description Briefly describe interior lighting system type and features. . Providing new pendant mount LED fixtures in new addition. At entries to new addition, existing 70W MH fixtures to be removed and replaced with LED downlights. At existing iI i a new room is beingadded in an existingspace with new LED office space of Building ng A, p fixtures. In the rest of this area, the existing fixtures will be re -arranged. Interior Lighting Power Allowance Method p Building Area Method ■ Space -by -space Method Select method used in project. Interior Lighting Controls in All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with th required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: 0 No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units Q C406.3 High Efficacy Lighting O R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Briefly describe exterior lighting system type and features. Remove existing 70W MH fixtures and replace with new LED fixtures. Existing exterior circuit controlled via building management system controls. REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC MAY 26 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWiLA APR 2 5 2017 PERMIT CENTER rollrolguda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 1— V 1- m 0 o • . o c0 rn • to O r O V Q rn N r eL O • I— 1- I— I-- .0 REVISION DATE Design: Drawn: Checked: Project No. DPH DPH DPH Issuance PERMIT SET Date: 4/14/2017 Drawing Title WSEC FORM Drawing Number CE0.02 CE0.02 WSEC FORM.DWG 2 N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC ' l':-."'.".t.'1,,``,`,,``O • • ••••,. : • .!ic:i7c,cc7c • „ I•c"..*licS; '1" ICI:, PROJECT'. LOCATION VICINITY MAP SCALE: NONE FLAN NOTES 0 PROVIDE 480/277 VOLT 3—PHASE 100 KW DIESEL GENERATOR WITH BASE TANK AND OUTDOOR ENCLOSURE. 0 PROVIDE 100 AMP NEMA 3R 3—POLE TRANSFER SWITCH. 0 PROVIDE CONDUIT AND FEEDERS FROM GENERATOR TO TRANSFER SWITCH LOCATED ON EXTERIOR WALL OF BUILDING '0'. ROUTE UNDERGROUND TO CORNER OF BUILDING 'A', AROUND THE EXTERIOR OF BUILDING 'A' THEN OVER ROOF TO TRANSFER SWITCH LOCATION. 0 ROUTE CONDUIT BETWEEN 'ATS' AND 'MDP' & PANEL 'PX' FROM MAIN ELECTRICAL ROOM D108 THROUGH CEILING SPACE OF 0107 TO 'ATS'. 0 SERVE TRANSFER SWITCH FROM. EXISTING 480/277V MDP DISTRIBUTION SECTION. NEW GENERATOR PANELS 'PX' AND 'PX1'. 0 PROVIDE NEW CARD READER AT DOOR. SEE SYSTEMS FLOOR PLANS. PROVIDE NEW CARD- READER AT GATE. SEE SYSTEMS FLOOR PLANS. - EXISTING CARD READER TO REMAIN. PLAN NOTES COMM 0 ROUTE EMT CONDUIT(S) UP CORNER OF BUILDING TO SOFFIT HEIGHT AND ROUTE CONDUIT ON FACE OF BUILDING JUST BELOW SOFFIT. 0 ROUTE EMT CONDUIT(S) ALONG WEST FACING SIDE OF BUILDING UNDER SOFFIT TO FLAT ROOF, AND TRANSITION UP TO FLAT ROOF. 0 ROUTE EMT CONDUIT(S) ALONG ROOF TOP TO BUILDING 'D'. PROVIDE ROOFTOP CONDUIT SUPPORT. 0 TRANSITION OFF ROOF TO SOUTH FACING WALL OF BUILDING 'D' TO 'ATS'. PLAN NOTES CONT'D 0 PROVIDE LB FITTING FOR ALL 90 DEGREE CONDUIT TURNS. PROVIDE ALL PULL POINT AS REQUIRED TO COMPLY WITH NEC. @ ROUTE EMT CONDUIT FROM NEW PANEL 'PX1' TO NEW PANEL 'PX2' THROUGH ATTIC SPACE IN BUILDING '0', ACROSS FLAT ROOF TOP BETWEEN BUILDING 'D' & 'E', AND THROUGH CEILING SPACE OF BUILDING 'E' TO NEW PANEL 'PX2' IN ROOM E130. FLAN NOTES cowl" 63 ROUTE EMT CONDUIT FROM NEW PANEL 'PX1' TO NEW PANEL 'PX2' THROUGH CEILING SPACE IN ROOM D107 TO FLAT ROOF, AND ALONG ROOF TO BUILDING 'C'. ROUTE THROUGH ATTIC SPACE BUILDING 'C' TO NEW PANEL 'PX3' IN ROOM C110. @ PROVIDE WALL PENETRATION AND SEAL AROUND ALL CONDUITS. • c, •••-liNCcs: SETBACK Matcallta ACSIMVUZin ' 5RAVEL TRAIL (ALTERNATE lt3) SEE LANDSCAP t2RAhINSS RAMP HR 130TH SIDES ` • EXISTINS BASEBALL. FIELD REPAIR TOP RAILS 4 PATCH FENCE 01 LANE:INS irn COVERED PLAY .SHED 11 [ _ tpfiwitippor MO 'Maki . e)•' HISH 12VMPSTER AREA 4' Hieff CHAIN LINK FENCE // 5" (Exivime) YARD ACK EX'S -MS SOCCER FIELD REPLACE TOP RAIL OF CHAIN LINK FENCE THREE BAYS •A 5 SIDE, APPRQX FIVE BAYS E SIDE 6;•••••••••0 • ,0 0•-•"' • • • ASPHALT FRP LANE CHAIN LINK SCREENED DUMPSTER AREA _MIN. °PENN& ( BUILD' G A EXIST. HYDRANT SIDE YARD SETBACK Or, 4< - REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 2 6 2017 i . : • . I ; 0 • 5 P OFF / EVENT P. City of Tukwila BUILDING DIVISION •RELOGATE SOFTBALL BACKSTOP SEE LANDSCAPE PRAIAIINOS 0.07 / • FL.A6 POLE FIXED • DOLLARD$; • REPLACE ONE SECTION,OF TORN CHAIN LINK FENCE • s.'`", --1‘;'-i,•- • •• SITE PLAN- ELECTRICAL SCALE : 1" = 30'-0" • ') • ,`;\ !,; )".:\.: • • • . I ' • ' • • 4j • • EXIST. HYDRANT 00 !i d •.; ;. • I . • • RECEIVED 0F TUKWILA APR 1i'2017 :::GENTER rolluda architects arch tecture planning inter or design. 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 tvv 11.1., ENGINEERS TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title SITE PLAN ELECTRICAL Drawing Number CE1.01 CE1.01_SITE.DWG t`•-• •Zr CZ) C I •=• • COPYRIGHT ,0 2015 ROLLUDA ARCHITECTS INC arch tecture planning interior design 1 1 TCS ILZE } 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 , 5 L r'1 L. 1)5E'; SSuS3 j TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com LA --5 NOTE 5 X24 I�Aln_� �Y . A1C):.. #10. 5C ,\1 1,5c� i t AG .4i 14 • 1141.11, • 1.3-;-9 #1 Odi NOTE 5 •0 iss FLAN NOTES O DISCONNECT AND REMOVE EXISTING COMPACT FLUORESCENT DOWNLIGHTS INTHE RECEPTION AREA. MAINTAIN CIRCUIT, CONTINUITY TO EXISTING FIXTURES TO REMAIN. TYPICAL OF THREE. 03 RELOCATE EXISTING FIXTURE TO NEW LOCATION IN THIS AREA. SEE SHEET CE7.01 NOTE 6 FOR NEW LOCATION. U REVISION DISCONNECT AND REMOVE EXISTING EXTERIOR. SOFFIT LIGHT FIXTURE.. REMOVE CONDUIT AND WIRING BACK TO NEXT ACTIVE FIXTURE TO REMAIN: MAINTAIN CONTINUITY TO ALL EXISTING FIXTURES TO REMAIN. • O5 REMOVE THE INTERIOR PORTION .OF THE EXISTING. FIXTURE. MAINTAIN CIRCUITING TO CONNECT TO NEW SURFACE . MOUNT FIXTURE. SEE CE7.01 FOR . NEW FIXTURE. • .1 BUILDING A & B - DEMOLITION LIGHTING PLAN t• 1 ,zy r � 1 •%:- ,� f's., 4.% _ • fr• er., r, RECEIVED CITY OF T UKWIL,A APR 2 5 2017 PERM T CENTER Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 26 2017 City of Tukwila. BUILDING DIVISION ;\ Drawing Title DEMOLITION PLAN - BLDG. A B LIGHTING Uri 3,0 $ Drawing Number CED1.01 KEY PLAN COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC CED1.01 BLDG-A B LTG.DWG 151 EN 11101110001 0 101010111111 al WI 010111128111 11110113001111 DI 11101110012111 1 1 WI W 1101=101111117IMI GATE G-3 ESL CLASS VOLUNTEER RM. A101 JANITOR CLST. A117 C1 1011000010 a - 01010110121 a -00121101101 -a INNWINNINI NI ELEC. CLST. A116 PLAN NOTES O REMOVE EXISTING ELECTRICAL OUTLETS FROM WALL TO BE DEMOLISHED AND PROVIDE NEW OUTLETS IN NEW WALL AS SHOWN. PROVIDE JUNCTION BOX AS REQUIRED AND EXTEND ALL CONDUIT AND WIRING FOR COMPLETE OPERATION. CIRCUIT INDICATED ON EXISTING DRAWINGS AS PB/3,5. (2 PROVIDE NEW POWER OUTLETS. O PROVIDE 120 VOLT CONNECTION TO NEW WALK-IN FREEZER BOX. SEE ROOF PLAN FOR FREEZER REFRIGERATION SYSTEM CONNECTION. O REMOVE EXISTING RECEPTACLE AND BACKBOX. PROVIDE NEW RECEPTACLE AND BACKBOX ON NEW WALL AS SHOWN. EXTEND ALL EXISTING CONDUITS TO NEW OUTLET BOX LOCATION. PULL NEW WIRING FROM FOURPLEX IN ROOM A113a AND FROM FOURPLEX IN A113 TO NEW OUTLET TO MAINTAIN CIRCUIT CONTINUITY TO ALL RECEPTACLES ON PA/7,9,11. 101100001 10110101411 NM - 0011W0011 - -1110100060- - 111011111161011 a -ESSIMISM - a 100111111101 - -0110101111111 MEN'S A102 rNEW GENERATOR SEE CE1.01 & CE5.01 0 PA/7,9,11 WOMEN'S A103 PNL L� PNL PA STAFF LOUNGE A104 STAFF WORKROOM A105 OFFICE A108 TOILET A109 HEALTH RM. A110 19 17 19 17 14_Ail_ j1-11 1 7 11 I OFFICE A113a PA/28 yr. II I I l I I 1 I GEN. REMOT= ANNUNCIATOR SUPPORT STAFF PA/28 CONF. RM A107 ,'-EXIST _ „le IDF-A RACK 17 PA/15,17,19 r STORAGE A111 :1111 RECEPTION A112 SECURED VESTIBULE 15 9H11 DRi1 A113 40�F+r--- --'1 PRINCIPAL OFFICE A114 42 40 38 Fl MIN 19'- 15 42 38 1440 OFFICE A115 40 'T 42 BUILDING A BUILDING A & B - FLOOR PLAN - POWER SCALE :1/8" =1'-0" PA/38,40,42 A5 PLAN NOTES CONt'A O5 EXISTING RECEPTACLES CURRENTLY INSTALLED IN COUNTER SHALL BE REMOVED AND REPLACED AFTER COUNTER RELOCATION. PROVIDE NEW DEVICES, CONDUIT AND WIRING FOR COMPLETE OPERATION. MAINTAIN ALL CIRCUITING AND CONTINUITY TO ALL EXISTING DEVICES ON THESE CIRCUITS. 0 PROVIDE NEW FOURPLEX IDF-A POWER OUTLET, CONDUIT AND WIRING TO NEW GENERATOR PANEL 'PX3'. PROVIDE ALL CONDUIT AND WIRING. O7 EXISTING EQUIPMENT CIRCUIT SHALL BE REMOVED FROM PANEL 'K' AND RE-ROUTED TO NEW PANEL 'PX1' AS INDICATED. PROVIDE ALL CONDUIT AND •WIRING. O8 EXISTING IDF OUTLET TO REMAIN AS GENERAL PURPOSE RECEPTACLE. O SWITCHED RECEPTACLE CONTROLLER TO BE LOCATED IN CEILING SPACE. PROVIDE CONTROLLER FOR NEW RECEPTACLES PROVIDED IN A113a. SEE OFFICE LIGHTING/ RECEPTACLE CONTROL DIAGRAM ON SHEET CE8.03. NV 111120100101 a - ININNINNIMIN a - PLAN NOTES COMT'G 10 DUPLEX AND DOUBLE DUPLEX RECEPTACLES SHALL BE SPLIT CONTROLLED RECEPTACLES. SEE DETAIL ON SHEET CE8.03. 11 PROVIDE A 1 -INCH CONDUIT AND WIRING TO SUPPORT STAFF ROOM A113 TO GENERATOR REMOTE ANNUNCIATOR. CONDUIT SHALL BE ROUTED UNDERGROUND TO BUILDING THEN OVERHEAD THROUGH BUILDING. 12 PROVIDE A 1 -INCH CONDUIT AND WIRING TO PANEL 'PX1' FOR GENERATOR OIL PAN HEATER AND BATTERY CHARGER. CONDUIT ROUTING SHALL FOLLOW GENERATOR FEEDER CONDUIT ROUTING AS INDICATED ON SHEET E1.01. 13 PROVIDE NEW REMOTE GENERATOR ANNUNCIATOR. I 10/11111101a NI 611 110810101111 0 IMINEWINI WI 10 1110110:01111 a 111110011=11 111 INNINSWIN 1111 INIMINUNNI IN 1113 10101100011 NS a la 33 111)33 33 3 TYP. r_ 31 CAFETERIA EXPANSION B113 PB/3I I • I Ix I I.,--- \\\�\, 31 31 ENTRY L __J EXIST REACH—IN FREEZER VESTIBULE B101 PB/33 31 XIT COVERED MAIN ENTRY 31 J BOYS B105 GIRLS B106 VESTIBULE 6102 EXIST COOLER PNZ K Q _..'i PX1/10 __.•' K 8 PX1 /14,16,18 J; GATE G-2 /8 GENERAL NOTES . EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 AWG FOR ALL CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT. ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. 116110/1111111 a s1000013010a--111101111111111- a a s DANNINNININ NI WI a-001110061 a-IMINININIEW a- 10101111011111'a .100011801 a - 101111101511-- - a110101110111 - a 1100111110111 a s 0100016110 a- KITCHEN B107 FOOD STORAGE B108 P.E. OFFICE/STRG. B109 EXISTING 200 AMP SHUNT TRIP MAIN BREAKER FOR EXISTING PANEL 'K' MULTI-PURPOSE/ CAFETERIA B103 P PR PNL I� CUST. B104 CHAIR STRG. B110 P.E. GYMNASIUM BUILDING B L_ REVIEWED FOR COMPLIANCE WITH NEPA 70 NEC MAY 2 6 2011 City of Tukwila BUILDING DIVISION G36 S RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER KEY PLAN rollutla architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 11.11. V V— TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com >-- Z z� Z 2 O J F -- w Q 0 wZ 5uJ w� (� J <0 00 (/) < U U CO w z 0 1– EP ti °. M o o rn 0) 0 CNI - a LLJ REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING A & B POWER Drawing Number CE2.01 CE2.01 BLDG-A B PWR.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA am E I awl I am t I am aas l i .iaf t: MSS i® i i® I MEM \\ \ \ \\ \\ ■as�i : aaa I anal , : am I ®. ! a® Qat : ID= SON ®i : am : OMNI \� \\ NOS ami Ilia WWI mo I I am am I am i ISM 1 ;ami I®: WM I anal i MN SUM ate GATE G-5 GENERAL„ NOTES 1. EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 AWG FOR ALL CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. rol itida architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 4. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. • EXISTING IDF—C RACK EXISTING POWER OUTLET SERVING IDF—C FLAN NOTES 01 PROVIDE NEW FOURPLEX IDF—C POWER OUTLET, CONDUIT AND WIRING TO NEW GENERATOR PANEL ''PX3'. PROVIDE ALL CONDUIT AND WIRING. O2 EXISTING IDF OUTLET TO REMAIN AS GENERAL PURPOSE RECEPTACLE. 0 DISCONNECT EXISTING FIRE/SMOKE DAMPER CIRCUIT FROM EXISTING PANEL 'PC' Sc RE -CIRCUIT TO NEW PANEL 'PX3'. CIRCUIT MAY BE RE—ROUTED FROM DEVICE HOME RUN OR EXISTING PANEL 'PC'. 0 PROVIDE NEW PANEL 'PX3'. SEE POWER ONE—LINE AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION.. DATA/STRG. 11111111111 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com NEW PNL PX3 PX3/2 GALLERY 3RD GRADE CLASSROOM PNL /PC EC 1 &2 �•�_ — PNL C PX3/2 3RD GRADE CLASSROOM Ct I-- zcf) LLIz 2p J W < 0 Z 5 W W Q o -J <0 0 0 (/) ©C 0 U u0 ft U) C1 2 co ...I co O Q oo QI-000cm WO O (n O O a Q 0 I < t- N et di: J rO Y O LU o . .N.� 7 CO z d' :j CL co I--- o I-- r I-- I-- . 2ND GRADE CLASSROOM REVISION DATE ARTS & SCIENCE CUSTODIAL STRG. D108 \ \ REVIEWED FOR COMPLIANCE WITH NFPA 70 m NEC MAY 2 6 2017 City of Tukwila BUILDING DIVISION RECEIVED Ci!'TY OF TUKWILA APR 2 5 2017 MIT CENTER E BUILDING C - FLOOR PLAN - POWER SCALE : 1/8" = 1'-0" ELri 030 8 KEY PLAN Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING C POWER Drawing Number CE2.02 CE2.02_BLDG-C PWR.DWG 2 0 N ti N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA MATCH LINE II 1N ItMNCI= 11 i1 EMI 11 131=II ! 1011111 I I® t HOMI 1 INViiSAO I ems::641114 I!NISK ! i I =NI I VIM RON ! ERNI 1 i.® I! 1191191IR= I® I® 11M I ® fl11111111 I= I In= 111611111 111111111 I MI ROI ION I ti GATE G-4 GIRLS 4TH GRADE CLASSROOM 5TH GRADE CLASSROOM DI 02 EXISTING POWER OUTLE SERVING IDF-D PD/48 !� EXISTING IDF-D RACK OFFICE/CONF. 4TH GRADE CLASSROOM STORAGE 5TH GRADE CLASSROOM L D104. • 4TH GRADE CLASSROOM D105 5TH GRADE CLASSROOM CUSTODIALETRG. GIFTED PROGRAM CLASSROOM NEW PNL 'PX1' NEW PNL 'PX' PX1 /17,19 CUSTODIAL STRG. D120 IATSI PX1 /15 FLOOR PLAN - BUILDING D - POWER SCALE : 1/8" = L -D4 GENERAL NOTES 1. EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 : AWG FOR ALL CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. PLAN NOTES EXISTING ACCESS CONTROL PANEL & POWER SUPPLY TO REMAIN. CONNECT EXISTING EQUIPMENT TO NEW POWER CIRCUIT. EXISTING PANEL CURRENTLY PLUGS INTO ADJACENT POWER OUTLET. REMOVE CORD AND PLUG AND PROVIDE HARD WIRE CONNECTION. PROVIDE NEW ACCESS CONTROL PANELS & POWER SUPPLIES FOR NEW ACCESS DOORS & GATES. rt)iluda architects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 REPLACE EXISTING MAIN FIRE ALARM PANEL AND DIALER WITH NEW FIRE ALARM PANEL WITH INTEGRAL REPORTING. THREE EXISTING AND ONE NEW FIRE ALARM NAC PANEL POWER SUPPLIES. EXISTING RECESSED NAPCO SECURITY PANEL. RE-ROUTE AND EXTEND SERVING 120 VOLT POWER CIRCUIT CURRENTLY CONNECTED TO EXISTING PANEL 'PD', TO NEW PANEL 'PX1' AS INDICATED. CIRCUIT MAY BE RE-ROUTED FROM EQUIPMENT OR FROM EXISTING PANEL. PROVIDE NEW FOURPLEX IDF-D POWER OUTLET, CONDUIT AND WIRING TO NEW GENERATOR PANEL 'PX1'. PROVIDE ALL CONDUIT AND WIRING. EXISTING IDF OUTLET TO REMAIN AS GENERAL PURPOSE RECEPTACLE. PROVIDE NEW NAC PANEL POWER SUPPLY AND CIRCUITING AS SHOWN. DISCONNECT EXISTING FIRE/SMOKE DAMPER CIRCUIT FROM EXISTING PANEL 'PD' & RE -CIRCUIT TO NEW PANEL 'PX1'. CIRCUIT MAY BE RE-ROUTED FROM DEVICE HOME RUN OR EXISTING PANEL 'PD'. PROVIDE NEW PANELS 'PX' & 'PX1'. SEE POWER ONE -LINE AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION. NEW TRANSFORMER 'TX' SHALL BE LOCATED IN ATTIC SPACE ABOVE. COORDINATE EXACT LOCATION OF POWER PANELS WITH OWNER PRIOR TO ROUGH -IN. PROVIDE NEW NEMA 3R ATS. SEE SHEET CE1.01 & CE5.01 FOR ADDITIONAL INFORMATION. FLS "7--63a 8 REVIEWED .FOR COMPLIANCE WITH NFPA 70 © NEC MAY 2 6 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 252017 PERMIT CENTER TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET KEY PLAN Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING D POWER Drawing Number CE2.03 CE2.03_BLDG-D PWR.DWG a N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA DAYCARE/PRESCHOOL PLAN NOTES O1 MAIN DATA ROOM WHICH INCLUDES INTERCOM, TV, VOICE & DATA HEAD END EQUIPMENT, ALONG WITH TELEPHONE & TV DEM ARC. KINDERGARTEN KINDERGARTEN ECEAP CLASSROOM TOILET TORAGE OFFICE GIRLS E124 COORIDOR PROVIDE NEW FOURPLEX IDF—E POWER OUTLET, CONDUIT AND WIRING TO NEW GENERATOR PANEL 'PX2'. PROVIDE ALL CONDUIT AND WIRING. EXISTING IDF OUTLET TO REMAIN AS GENERAL PURPOSE RECEPTACLE. RE—ROUTE AND EXTEND SERVING 120 VOLT RECEPTACLE POWER CIRCUITS CURRENTLY CONNECTED TO EXISTING PANEL 'PE', TO NEW PANEL 'PX2' AS INDICATED. CIRCUITS MAY BE RE—ROUTED FROM RECEPTACLE OR FROM EXISTING PANEL. TYPICAL OF SIX DEDICATED FOURPLEX OUTLETS IN THIS ROOM. DISCONNECT EXISTING FIRE/SMOKE DAMPER CIRCUIT FROM EXISTING PANEL 'PE' & RE—CIRCUIT TO NEW PANEL 'PX2'. CIRCUIT MAY BE RE—ROUTED FROM DEVICE HOME RUN OR EXISTING PANEL 'PE'. DISCONNECT EXISTING FIRE/SMOKE DAMPER CIRCUIT FROM EXISTING PANEL 'PF' & RE—CIRCUIT TO NEW PANEL 'PX2'. CIRCUIT MAY BE RE—ROUTED FROM DEVICE HOME RUN OR EXISTING PANEL 'PF'. 07 PROVIDE NEW PANEL 'PX2'. SEE POWER ONE—LINE AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION. OFFICE 1ST GRADE CLASSROOM El 06 MECH / ELEC / BOILER STAFF TOILET SELF-CONTAINED CLASSROOM TOILET SELF-CONTAINED / RESOURCES CLASSROOM SM. GROUP VESTIBULE GIRLS OFFICE CORRIDOR THERAPY RM E110 LIBRARY 1ST GRADE CLASSROOM El 03 PX2/4 PX2/6 PF/19 PATCH RM E104A .41 -- \ \ OFFICE EXISTING POWER OUTLET SERVING IDF—E EXISTING IDF—E RACK \ \ 1ST GRADE CLASSROOM E101J PX2/7,9,11 PANEL C1 VIEWE PLIAN FOR WITH EC 017 COMPUTER LAB City Tu DIVISI E4 El =ES= El PS ISSISSISEI IS 111226001 El El 100011011101 III El SEISES= 0 1111118111 IN 0 111111011111111 El IS 1150E00a 1111 ESIESSIE1 1111 ISEMSEI 1111 1110011111111 1111 MI MEE= 01 0 10018101111 IS 0 Ill01111001 SI SEESSISSI EI MATCH LINE la 0 ISSESS110111 011211=1 1111 1011120211 al SEESIMIEll 1111 1111 SEEM= SS IIIESSE011 0 11011101011 111 IS IESSIZEISI IN IMEISSEal 111 0 01116/001 0 IS 11111111111111111 El 2111101111111111 12121/110110 IN PR 2 5 017 ESSER= IN 1111 111100111100 El Ell 1 PER 'E \ITER 1 FLOOR PLAN — BUILDING E — POWER GENEFRAL NOTES 1. EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 AWG FOR ALL CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' Se 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWTSE NOTED. 4. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. rolguda architects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 11000101011 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com LLI • 0 co 1 < 0 0 u) 1- 0 ci ccl 71" 5• - Ric° ..,--§ csiii,E fi "§". (I) § REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN — BUILDING E POWER Drawing Number CE2.04 KEY PLAN COPYRIGHT 2015 ROLLUDA ARCHITECTS INC CE2.04_BLDG _E PWR.DWG 0.1 PLAN NOTES O1 EXISTING FIRE ALARM REMOTE LCD ANNUNCIATOR TO REMAIN. O RELOCATE EXISTING FIRE ALARM HORN/STROBE AND SOUND SYSTEM DEVICES TO NEW WALL AS SHOWN. 03 PROVIDE NEW CARD READER AT GATE. ROUTE CONDUIT AND WIRING TO NEW ACCESS CONTROL PANEL IN BLDG. 'D' ROOM D115. � PROVIDE NEW DIGITAL CLOCK SPEAKER, CONNECT TO EXISTING RAULAND TELECENTER SYSTEM 21 INTERCOM SYSTEM. SEE SHEET CE8.03 FOR ADDITIONAL INFORMATION. PROVIDE NEW CAT 6 TELECOM OUTLET, ROUTE TO NEW CAT 6 PATCH PANEL IN EXISTING IDF-A. CONCEAL CONDUITS IN WALLS AND CEILING SPACE WHERE POSSIBLE. PLAN NOTES coNT'D O PROVIDE ALARM CONNECTION FROM FREEZER TO SECURITY PANEL IN BUILDING 'D' ROOM D115. • PROVIDE NEW CARD READER AT DOOR. ROUTE CONDUIT AND WIRING TO NEW ACCESS CONTROL PANEL IN BLDG. 'D' ROOM D115. O8 EXISTING FIRE ALARM GRAPHIC ANNUNCIATOR TO REMAIN. UPDATE WITH NEW CAFETERIA EXPANSION AREA. O EXISTING LOCKDOWN DEVICE TO REMAIN. 10 PROVIDE AIPHONE AX-DVF VIDEO DOOR STATION. PROVIDE CAT 6 CABLE FROM DEVICE TO NEW PATCH PANEL IN IDF-A RACK. 11 PROVIDE AIPHONE AX-8MV MASTER STATION. PROVIDE CAT 6 CABLE FROM DEVICE TO NEW PATCH PANEL IN IDF-A RACK. 12 13 14 15 16 17 FLAN NOTES CONT'o RELOCATE EXISTING FIRE ALARM PULL STATION AND PROTECTIVE COVER TO NEW ENTRY/EXIT VESTIBULE AS APPLICABLE. RELOCATE EXISTING FIRE ALARM PULL STATION AND COVER TO THIS LOCATION. PROVIDE NEW BACK BOX CONDUIT AND WIRING. PROVIDE NEW SMOKE DETECTOR. PROVIDE NEW SECURITY MOTION DETECTION. AND CONNECT TO EXISTING NAPCO ALARM SYSTEM. EXISTING DATA OUTLET TO REMAIN. PROVIDE NEW FIRE ALARM HORN/STROBE. FLAN NOTES =NM 18 PROVIDE FIRE ALARM CONNECTION TO DUCT SMOKE o DETECTOR FOR NEW MECHANICAL UNIT HP_ B01 LOCATED ON ROOF. DUCT SMOKE DETECTOR PROVIDED WITH UNIT. 19 PROVIDE AIPHONE CENTRAL EXCHANGE UNIT AS -084C AND SOFTWARE FOR CONNECTION OF AIPHONE VIDEO DOOR STATION AND MASTER STATIONS. PROVIDE ALL EQUIPMENT AND CONNECTIONS FOR COMPLETE OPERATION. 20 PROVIDE (1)3" CONDUIT SLEEVE BETWEEN A105 & A111 FOR TELECOM CABLE ROUTING. c all IMMISMOMMI --MIMMIMISMI --MICOMIMall ..ISM= .m IMMIMMIMMI ..IMMIMMMMX ..IMMISMIMMI .. r . Mi 11112121111M1 r ® IMOMMIIIMI s m DiMUMMIMMil • IMMIMIMIMMI .. MISAMMOMMI.. --IMIMMOMIll -- --MMAIMMOMM MI MI Matillatill -- IMUMMMilla_- EXISTING CARD READER TO REMAIN. GENERAL NOTES 1. FIRE ALARM SYSTEM SHALL BE BIDDER DESIGN. SEE SHEET CE8.01 & SPECIFICATIONS SECTION 283100. 2. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. rolluda architects architecture punning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 - ..IMMOMMOS .. IMMIMMiall .. .m1111118MMIMM.® MIMMIMM011 .. IMMOMMIIMIM.BIIIIMMDM011®®IMMIMISMIMI ®. MI BM Mann AM IMMIIMMIGM MI Mallailall 1111 MMINIMIMMI Mil MI IMOMMIIMM GATE G-3 GATE G-2 NEW CARD READER. MEN'S ENTRY TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com ELEC. CLST. KITCHEN ESL CLASS VOLUNTEER RM. STAFF LOUNGE P.E. OFFICE/STRG. JANITOR CLST. WOMEN'S VESTIBULE RE. GYMNASIUM STAFF WORKROOM CONF. RM CAFETERIA EXPANSION MULTI-PURPOSE/ CAFETERIA GIRLS OFFICE TOILET w � 1 F��M,--- U REVISION VESTIBULE HEALTH RM. CHAIR STRG. RECEPTION SECURED VESTIBULE OFFICE A113a EXISTING CARD "EADER TO REMAIN. COVERED MAIN ENTRY BUILDING B VIEWED FOR COMPLIA IPPA 70 - NES SUPPORT STAFF MAY 2 6 2017 Design: Drawn: Checked: Project No. FLR BT FLR "`" City of.Tukwilii BUILDING DIVIS Og' • RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER Issuance PERMIT SET PRINCIPAL OFFICE A114 1 OFFICE BUILDING A Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING A & B SYSTEMS CE3.01 BLDG-A B SYS.DWG BUILDING A & B - FLOOR PLAN - SYSTEMS SCALE : 1/8" =1'-0" Drawing Number 036 8 CE3.01 KEY PLAN COPYRIGHT 0 2015 ROLLUDA ARCHITECTS IN l i® I I INEM I WEI ®:ice; e® 1119191 Mai MI • Ina1 ml ia: ® I tWIN I ® I I® t I® 111411 rr a 1® ® I ®! P. i M N IMMI I ® I I® t® I MN ® i® MIi i® I iIan I iISM ! I m i I EOM; I MNi NOSI i mr iBUSI / NEW CA D READER GATE G-5 EXISTING IDF-C RACK % 3RD GRADE CLASSROOM DATA/STRG. NEW PNL PX3 GALLERY 3RD GRADE CLASSROOM PNL /PC EC 1 & 2 & — PN LC 2ND GRADE CLASSROOM ARTS & SCIENCE CUSTODIAL STRG. D108 BUILDING C - FLOOR PLAN - SYSTEMS SCALE : 1/8" = 1'-0" 1 GENERAL RAL NOTE S 1. FIRE ALARM SYSTEM SHALL BE BIDDER DESIGN. SEE SHEET CE8.01 & SPECIFICATIONS SECTION 283100. 2. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. PLAN NOTES 0 PROVIDE NEW CARD READER AT GATE. ROUTE CONDUIT AND WIRING TO NEW ACCESS CONTROL PANEL IN BLDG. '0' ROOM 0115. Lf7 030 rolluda architects architecture planning inter or design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION REVIEWED FOR COMPLIANCE WITH NFPA7O- NEC MAY 2 6 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY O► TUKWILA APR 25 2017 PERMIT CENTER B KEY PLAN Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING C SYSTEMS Drawing Number CE3.02 CE3.02_BLDG-C SYS.DWG O Cs1 CV COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC' MATCH LINE 1® 11 RN1 1 SION1 ® 1 1 I I® 1 iOMI[Stall I 1 NMI ® ® 1 I OWN I IBJ I 1 1m 1 ® ! ® ! .m I ® I ® I =I I I- ® i! ®1 1 I® t I i671Will GATE G-4 GIRLS GENERAL NOTES . . 1. FIRE ALARM SYSTEM SHALL BE BIDDER DESIGN. SEE SHEET CE8.01 & SPECIFICATIONS SECTION 283100. 2. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. PLAN NOTES O1 EXISTING FOUR CARD READER ACCESS CONTROL PANEL AND POWER SUPPLY TO REMAIN. 02 EXISTING SONITROL SECURITY ALARM PANEL LOCATED BETWEEN ACCESS CONTROL PANEL AND POWER SUPPLY TO REMAIN. O3 PROVIDE (2) NEW FOUR CARD READER ACCESS CONTROL PANEL WITH POWER SUPPLY. O4 REPLACE EXISTING ADDRESSIBLE EST QUICK START FIRE ALARM PANEL WITH NEW EST I0500 ADDRESSIBLE FIRE ALARM PANEL WITH INTEGRAL POINT ID CENTRAL STATION REPORTING. O5 PROVIDE NEW FIRE ALARM NAC POWER SUPPLY ABOVE THE THREE EXISTING POWER SUPPLIES FOR NEW ADDITION DEVICES. O PROVIDE SINK MODULES ADJACENT TO, AND NEW BATTERIES INSIDE THE THREE EXISTING NAC POWER SUPPLIES. O7 PROVIDE NEW NAC FIRE ALARM POWER SUPPLY IN THIS ROOM TO SUPPORT THE EXISTING HORN/STROBE CIRCUITS IN BUILDING D & E. O8 EXISTING NAPCO SECURITY PANEL TO REMAIN. rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com NEW ACCESS CONTROL PANEL OFFICE/CONF. EXISTING ACCESS CONTROL PANEL STORAGE 4TH GRADE CLASSROOM 5TH GRADE CLASSROOM REVISION GIFTED PROGRAM CLASSROOM CUSTODIAL STRG. D120 NEW PNL 'PX1' NEW PNL 'PX' PNL PD SEC 1 ii/PNL PD SEC 2 PNL LD EXISTING MDP 1 -1 I i I L ---J I -_I REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 26 2017 City of .Tukwila BUILDING DIVISION Design: Drawn: Checked: Project No. FLR BT FLR RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMITCENTER Issuance PERMIT SET FLOOR PLAN - BUILDING D - SYSTEMS SCALE :1/8" = KEY PLAN Date: 4/14/2017 Drawing Title FLOOR PLAN BUILDING D SYSTEMS Drawing Number CE3.03 CE3.03 BLDG-D SYS.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC �E16 DAYCARE/PRESCHOOL E123 (E15� KINDERGARTEN E111 KINDERGARTEN ECEAP CLASSROOM GENERAL NOTES 1. FIRE ALARM SYSTEM SHALL BE BIDDER DESIGN. SEE SHEET CE8.01 & SPECIFICATIONS SECTION 283100. 2. CONCEAL AND ROUTE ALL NEW CONDUITS WITHIN WALLS AND CEILING SPACE WHENEVER POSSIBLE. WHERE CONDUIT ROUTING IS REQUIRED BETWEEN BUILDINGS, CONDUIT SHALL BE ROUTED OVER FLAT PORTION OF ROOF. PROVIDE ALL CONDUIT SUPPORTS, BUILDING PENETRATIONS AND CONDUIT SEALING. PIAN NOTES architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 1 PROVIDE NEW CARD READER AT DOOR. ROUTE CONDUIT AND WIRING TO NEW ACCESS CONTROL PANEL IN BLDG. 'D' ROOM D115. TOILET TORAGE E121 OFFICE GIRLS I SI SI ISSISSISSII IFY,Liti CARD READER. 1ST GRADE CLASSROOM El 06 1ST GRADE CLASSROOM El 03 1ST GRADE CLASSROOM E101 CORRIDOR E110 BOYS El 09 STAFF TOILET El 08 GIRLS E107 THERAPY RM El 05 PATCH RM I r— E 104A --'� --1 OFFICE MI MI III MI SISISSIMS SI IS 7 E104 EXISTING IDF-E RACK PNL PF PNL COORIDOR SELF-CONTAINED CLASSROOM E115 El 26 OFFICE E116 TOILET E117 OFFICE E118 SELF-CONTAINED / RESOURCES CLASSROOM E119 VESTIBULE E127 MUSIC CLASSROOM E102 IS SI IISSESISS SI ISISSISSUI IS MI ISMS= NS III SIIISINSII 1111 FLOOR PLAN - BUILDING E - SYSTEMS SCALE : 1/8" = 1'-0" IS 1101 11111/11MBSSI SI SI SISSIZINS OE INSSINIES 1111 1111 111= NEW CARD READER. NEW PANEL 'PX2' TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com MECH / ELEC / BOILER SM. GROUP LIBRARY / EXISTIP &TVH EXISTING TELE DEMARC WORKROOM INTERCOM D ENDS REVISION EXISTING MDF ROOM EXISTING MDF RACK PANEL C1 WITH c COMPUTER LAB City 0 BUILDIN u ila r I ISION Design: Drawn: Checked: Project No. FLR BT FLR MI IS (E 14/ ISISISSESI RS MS ISSIMISOISI Si (J F T Ari !, .2' .. PERM '' 'El TER. Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING E SYSTEMS Drawing Number Effirmi 0309 CE3.04 KEY PLAN CE3.04 BLDG E SYS.DWG N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC / ,/ 0 EXISTING 3/4"C, (3)#8 & LA/20,22,24 (1)#10 GND Cu. J y` Al T J 0 0 // 100 'AMP/(3)80(V 1-1/4"C, (3)#3 \ & (1)#8 GND Cu. \ 0 WP B/38,40,42 3/4"C, (2)#10 & (1)#12 GND Cu. PX1 /4y6'7 0 L 60 AMP/(3)40AF LFJ EXISTING 3/4"C, (3)#8 & LB/14,16,18 (1)#10 GND Cu. 60 AMP/(3)60AFLFJ GENERAL NOTES . EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. EXISTING 1"C, (3)#4 & LB/20,22,2(41)#10 GND Cu. 0 J 0 PROVIDE #10 AWG FOR ALL BRANCH CIRCUITS ROUTED TO NEW PANELS 'PXl', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING: TO REMAIN UNLESS OTHERWISE NOTED. 4. ALL CONDUITS ROUTED ON ROOF SHALL BE SUPPORTED WITH CADDY PYRAMID CONDUIT SUPPORTS. 00 \0 0 00 BUILDING A A6 BUILDING A & B - MECHANICAL ROOM AND ROOF PLAN 2 SCALE : 1/8" =1'-0" BUILDING B EMT CONDUIT SIZE AND QUANTITY AS INDICATED ON PLANS. SUPPORTS SHALL BE 'CADDY PYRAMID' ROOFTOP CONDUIT AND EQUIPMENT SUPPORTS BY ERICO INTERNATIONAL CORPORATION. ROOFTOP CONDUIT MOUNTING DETAIL NO SCALE FLAN NOTES 0 DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO EXISTING CU UNIT, FOR UNIT REPLACEMENT. PROVIDE NEW WEATHER TIGHT FLEXIBLE CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO NEW CU UNIT. CONDUIT AND WIRING SIZES TO REMAIN THE SAME. EXISTING HOMERUN CONDUIT AND WIRING FROM DISCONNECT TO PANEL TO REMAIN. O O PROVIDE NEW ELECTRICAL CONNECTION TO NEW HP—B01. PROVIDE CONNECTION TO NEW FREEZER REFRIGERATION SYSTEMS LOCATED ON ROOF. NEW ROOFING MATERIAL PROVIDED IN THIS AREA. ELECTRICAL CONTRACTOR TO DISCONNECT AND RECONNECT ALL EQUIPMENT AS REQUIRED FOR ROOF WORK. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 46-7 036 IEWED FOR COMPLIANCE WITH NFPA 70 NEC MAY 2 6 2017 City of Tukwila UILDING DIVISION RECEIVED CTY OF TUKWILP APR 2.52017 PE.FIMIT CENTER KEY PLAN rolitida architects. arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 V V— TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com co 0 5 REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title BLDG. A & B - MECH ROOM & ROOF PLAN Drawing Number CE4.01 CE4.01 BLDG A B MECH ROOM & ROOF PLAN.DWG N 'Cr ti 0 N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC MI . 115011101011® MI 140001101M MATCH LINE 111011081111 MISS16111001011 EI 0110111/10 OS 111110111011110 MI MI 10011611010MI MI MESA= SI 111 111101010421 OS El II= 1111 011140110111 1111 SE 011011101110 0 1111110110110 111 1110101004411 0 El 101110101011 111 0101111001 BE / rf 61 A P%(3) OAF 101001111131160 0 11100011001®.110112101200.® 0111100111011 MISS -a MI MI — VI 011 101111101001 - 01 10011100111 NI EA 1120001111111 01 Ell 111011101110 la SO 101100111111 MISS MATCH LINE BUILDING C - MECHANICAL ROOM AND ROOF PLAN SCALE : 1/8" =1'-0" ti 0 0 1111 =0 MN 1011111111010 El 101 ERINSIPMEI 11001811011 Si 11011101110101 ZS 12311112611061 GENERAL NOTES EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL .CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 AWG FOR ALL BRANCH CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. ALL CONDUITS ROUTED ON ROOF SHALL BE SUPPORTED WITH CADDY PYRAMID CONDUIT SUPPORTS. 'LAN NOTES 0 DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO EXISTING CU UNIT, FOR UNIT REPLACEMENT. PROVIDE NEW WEATHER TIGHT FLEXIBLE CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO NEW CU UNIT. CONDUIT AND WIRING SIZES TO REMAIN THE SAME. EXISTING HOMERUN CONDUIT AND WIRING FROM DISCONNECT TO PANEL TO REMAIN. ELi7- O30 REVIEWED .FOR COMPLIANCE WITH NFPA70 n NEC MAY 2 6 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER KEY PLAN roilua architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 V V— TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com Ct z� W•Z 20 J W \< 0 W Z / LLI�// " I.L- co LiPai < O d UOQ (i) = M g U to m 0 0 1 -- co— 62 0 0 z co o I— I— I— REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title BUILDING C - MECH ROOM & ROOF PLAN Drawing Number CE4.02 CE4.02 BLDG-C MECH ROOM & ROOF PLAN.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA MATCH LINE 1 III MI MI 81111161111211 IM 1111 12621224111 111 MN 1111062111111 1111 0 122112221 IM 1M 01111111262 MI MI M112221611 OM MI 182111611011 2 MI 111012116101 III 0 11112121211 IM 1120216111111 2 0 7 1111 012202211 1111 MI 12111111111211 MI MI IMMO= MI 111 112126:1611 131 2 MI 1600112111 111 MI 1121610119111 1120212111 MI MI 102221111 MI 161 ausztanzei®® sassanas - 111121111112213111 - ;l NEW 75 KVA TRANSFORMER 'TX' 11121111281111 - - -- - 1122211121101 BM - IMMO= II IIILI MATCH LINE 0221626621 MI 0 101022261 El MI 11611219111 1111 1112111119221 1212111911M1 MI 61 12221122121 MI 0 012121221 0 0 0211121211 O O BUILDING D -MECHANICAL ROOM AND ROOF PLAN SCALE : 1/8" =11-0" - - 6921128261 - - 112122031211 1211212102 1M 11121221111111 MI MI 112612111211 - - DE; GENERAL NOTES 1. EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 2. PROVIDE #10 AWG FOR ALL BRANCH CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. ALL CONDUITS ROUTED ON ROOF SHALL. BE SUPPORTED WITH CADDY PYRAMID CONDUIT SUPPORTS. 'LAN NOTES O DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO EXISTING . CU UNIT, FOR UNIT REPLACEMENT. PROVIDE NEW WEATHER TIGHT FLEXIBLE CONDUIT AND WIRING FROM. EXISTING DISCONNECT SWITCH TO NEW CU UNIT. CONDUIT AND WIRING SIZES TO REMAIN THE SAME. EXISTING HOMERUN CONDUIT AND WIRING FROM DISCONNECT TO PANEL TO REMAIN 0 PROVIDE NEW 75 KVA 480-208/120V 30 TRANSFORMER 'TX'. LOCATE DIRECTLY ABOVE PANELS 'PX'. & 'PX1' IN ROOM D108 BELOW. REVIEWED FOR COMPLIANCE WITH NFPA 70 4 NEC MAY 2 6 2017 '� City of Tukwila BUILDING DIVISION rellucla architects architecture planning interior design 105 S. Main Street Suite 323 Seattle,. WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION RECEIVED CIT'l OF TUKVVILi=. APR 252017 PERMIT CENTER Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET ELf33oFi KEY PLAN Date: 4/14/2017 Drawing Title BUILDING D - MECH ROOM & ROOF PLAN Drawing Number CE4.03 CE4.03-BLDG-D_MECH ROOM & ROOF PLAN.DWG 0- N N- 0.1 N CV COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA 5/ FLAN NOTES O DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO EXISTING CU UNIT, FOR UNIT REPLACEMENT. PROVIDE NEW WEATHER TIGHT FLEXIBLE CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO NEW CU UNIT. CONDUIT AND WIRING SIZES TO REMAIN THE SAME. EXISTING HOMERUN CONDUIT AND WIRING FROM DISCONNECT TO PANEL TO REMAIN. EXISTING CIRCUIT SHALL BE REMOVED FROM SERVING PANEL 'Cr AND RE—ROUTED TO NEW PANEL 'PX2'. PROVIDE ALL CONDUIT AND WIRING. rolltida. architects architecture planning inter`or• design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 M1/32,34,36 EXISTING 3/4"C, (3)#8 & 1)#10 GND Cu. OAF TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com EXISTING MDF AC REVISION / , , , , \ \ 0 REVIEWE4 ' 9R COMPLIARICITH 9dFPA 70 - MAY 2 6 201 City of Tukwil BUILDING DIVISI Design: Drawn: Checked: Project No. FLR BT FLR , RECEIV CITY OF TU SWE0®EISESESSEI 0- 1111001110 0 0 ISESE0101 0 0 1111003011 0 0 -- ® 80011200E1®. 60 AMP/(3)60AF F 1j r I L I 11128103101 0® SENCIESSE 111041/1001 - 0 1 M1/50,52,54 I � EXISTING 1"C, (3)#4 & (1)#10 GND Cu. BUILDING E - MECHANICAL ROOM AND ROOF PLAN SCALE : 1/8" = 1'-0" GENERAL NOTES 1. EXISTING CIRCUITING INDICATED ON THESE PLANS ARE TAKEN FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. E.C. SHALL FIELD VERIFY ALL CIRCUITING PRIOR TO WORK. 0® 1111000011 Oa -- PERMi(' CENTER 0 0ISESEESSIE0 0 11313181011110 0 11000311311F� Issuance PERMIT SET 0 0 Date: 4/14/2017 2. PROVIDE #10 AWG FOR ALL BRANCH CIRCUITS ROUTED TO NEW PANELS 'PX1', 'PX2' & 'PX3' UNLESS OTHERWISE NOTED. 3. ALL ELECTRICAL PANELS, CONDUIT, DEVICES, EQUIPMENT ETC. THAT IS SHOWN DASHED IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. ALL CONDUITS ROUTED ON ROOF SHALL BE SUPPORTED WITH CADDY PYRAMID CONDUIT SUPPORTS. Drawing Title BUILDING E - MECH ROOM & ROOF PLAN Drawing Number Lid 03a8 B CE4.04 KEY PLAN CE4.04 BLDG-E MECH ROOM & ROOF PLAN.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA TO EXISTING rEXISTING MAIN SWITCHBOARD 480Y/277V 30 4W 1200 AMP UTILITY TRANSFORMER 1200/3 /AF W/GFI (3)600/ AF 600/3 r EXISTING 1 DISTRIBUTION PANELBOARD DP 480Y/277V 30 4W L 600 AMP <2> ^ <'3\> r ----I <12> I --I<'11 > <'11�> (-•-----I-----3 I-- '---(1 -1- - - H PANEL LD H - - TD -166 H PANEL PDI PANEL PD I (3)200/AF L ---J L -JJ_ L---J----J 200/3 200A ENCLOSED CB SEC. 1 SEC. 2 200A ENCLOSED CB ^ ^ <'3/> r----1 <12><'11/> I - �--rl -I - - - -I PANEL LC I- -" - �C I �` (3)200/AF L — — — J L_ —JJ_ 200/3 <'2/> r----1 <10> r-1 s 7 (3)300/A-F—E— — —I PANEL LB i- "- 1 TB J_ m 400/3 T 0 1 <12> �--1< 11/> L ---Y-- TK ,__,4—! ^ SEC. 1 SEC. 2 <'11�> r----r----I C --1 PANEL PCI PANEL PC 0 0 (NI <\9�> (-----1 -1` -I PANEL PB I__J <'11•> r ----i —1 PANEL K L ---J 200A ENCLOSED CB 175A ENCLOSED CB ^ ^ ^ ^ (3)200�F1- ' - �L PANEL LA I- �'L — �TAJ J_ L6 -i PANEL PA I 200/3 (3)100 AF 200/3 100 AMP 3 -POLE ATS 480/277V O•80 -208/120V 1P PANEL PX 200 AMP FUSED 208/120V 75 - STANDBY ATS KVA TRANSFER SWITCH #2 Cu. 100 AMP 3 POLE ARTICLE 702 " SPARE 2" C.O. FUTURE ATS 1--- ---I-- SPACE 3/0 Cu. SPARE FUTURE ATS � 2" C.O. 100/3 100/3 100/3 DISC 208/120V PANEL PX2 208/120V PANEL PX3 1"c, (4)#18 & (4)#23 Cu. 480/277 100 KW GENERATOR NEC ARTICLE 702 T r m 0 O 0 co J ^ ^ <'\ 3> r ---7 <12> I — (3)200/AFS �' —I PANEL LE I- -.,,.- L—_—J 200/3 SEC. 1 SEC. 2 r —1 <13> r---T----I ---PANEL PEI PANEL PEI iL----I-----I I <14>r ----I \-'2-1 PANEL C1 1 L ---J 100A ENCLOSED CB <'4/> r ----I <10> �-� 9 r--1 <�9�> r----1 - �"� - - -I PANEL LF i- - - TF I �"�-6 �"� — -i PANEL PF1 (3)100/ L ---J L_L---J 100/3 <5> (3)400/AF 400/3 100/3 1- - 1 -- POWER ONE -LINIAAM SCALE: NONE NOTE: ALL DASHED LINES INDICATE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. ALL SOLID LINES INDICATE NEW TO BE PROVIDED. MECHANICAL EQUIPMENT SCHEDULE MISC EQUIP. VOLT/ PHASE LOAD CIRCUIT CONDUTT/WIRE SIZE FUSED DISC. RANUAL MTF STARTER MAGNETIC 4TR STATEF PILOT SW AFC IN AMPS AT PANEL REMARKS AMP KVA/W HP BKR PANEL Air -Cooled Condensing Unit 230 A 480 13 - 40/3 LA 3/4"C, 3 #8 & (1)#10 GND EXIST. TO REMAIN ON ROOF O 1• 480 / 3 - 40/3 LB 3/4"C, 3 #8 & (1)#10 GND EXIST. TO REMAIN ON ROOF O Mk Mar 480 / 3 - - 60/3 LB 1"C, 3 #4 & (1)#10 GND EXIST. TO REMAIN ON ROOF O 480 13- - 50/3 LC 3 #6 & (1)#10 GND EXIST. TO REMAIN ON ROOF 9 O AIL3/4"C, Mir 480 / 33/4"C, - - 50/3 LD 3 #6 & (1)#10 GND EXIST. TO REMAIN ON ROOF O m- Illy 480 13 - 60/3 M1 SEC 2 1"C, 3 #4 & (1)#10 GND EXIST. TO REMAIN ON ROOF O m I� 480 13 - 60/3 M1 SEC 1 1"C, 3 #4 & (1)#10 GND EXIST. TO REMAIN ON ROOF O 7 480 / 3 - _40/3 - M1 SEC 1 3/4"C, 3 #8 & (1)#10 GND EXIST. TO REMAIN ON ROOF O T PACKAGED ROOFTOP HEAT PUMP 480 13 63.8 -- 80/3 LB 1-1/4"C, 3 #4 & (1)#8 GND BY E.C. ON ROOF 10 Ala lilir SPARE SPACE SPACE r ----r---7 <18> I— • PANEL M11 PANEL M1 I– — _ -A L _▪ SEC 1 J_ SEC 2 J L J J_ <14> r----1 - .,---I PANEL MP1I L NEW FEEDER SCHEDULE TYPE DESCRIPTION AMP 2"C, 4 #1 & 1 #4 Cu. GND 130 A 1P 2"C, 3 #1 & 1 #8 Cu. GND 130 A ® 2"C, 4 #1 & 1 #8 Cu. GND 130 A ® 2"C, 4 #2/0 & 1 #4 Cu. GND 175 A 2-1/2"C, 4 #4/0 & 1 #2 Cu. GND 230 A ALL FEEDERS CONDUCTORS SHALL BE THHN-THWN COPPER(Cu.) CONNECT INSL/ISO GROUND CONDUCTOR FROM PANEL INSL/ISO GROUND BUS TO MAIN SWITCHBOARD SERVICE GROUND. E 036Z PLAN NOTES • PROVIDE NEW FUSED DISCONNECTS IN EXISTING FUSED SWITCH SECTION. O PROVIDE NEW NEMA -3R 100 -AMP 3 -POLE AUTOMATIC TRANSFER SWITCH. SEE SPECIFICATION 263600 FOR ADDITIONAL REQUIREMENTS. O PROVIDE NEW 100 KW GENERATOR. WITH (3)100/3P BREAKERS. ONE BREAKER SHALL SERVE NEW ATS AND TWO SHALL BE SPARE. SEE SPECIFICATION 263213 FOR ADDITIONAL REQUIREMENTS. • PROVIDE 2" CONDUIT WITH PULL STRING FROM GENERATOR TO EXTERIOR WALL OF BUILDING A. STUB UP SIX INCHES ABOVE GRADE AND CAP OFF. O PROVIDE 480/277V 30 4W 100 -AMP PANEL WITH MAIN BREAKER IN ROOM D108. SEE PANEL SCHEDULE FOR ADDITIONAL REQUIREMENTS. O PROVIDE 480-208/120V 30 4W 75 KVA TRANSFORMER. LOCATE IN ATTIC SPACE ABOVE PANEL 'PX' & 'PX1'. SEE SHEET CE4.03 FOR LOCATION. • PROVIDE 208/120V 30 4W 200 -AMP PANEL WITH MAIN BREAKER IN ROOM D108. SEE PANEL SCHEDULE FOR. ADDITIONAL REQUIREMENTS. O PROVIDE 208/120V 30 4W 100 -AMP PANEL WITH 60 -AMP MAIN BREAKER. SEE PANEL SCHEDULE FOR ADDITIONAL REQUIREMENTS. SEE SHEETS CE2.02 & CE2.04 FOR LOCATIONS • DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO EXISTING CU UNIT, FOR UNIT REPLACEMENT. PROVIDE NEW WEATHER TIGHT FLEXIBLE CONDUIT AND WIRING FROM EXISTING DISCONNECT SWITCH TO NEW CU UNIT. CONDUIT AND WIRING SIZES TO REMAIN THE SAME. EXISTING HOMERUN CONDUIT AND WIRING FROM DISCONNECT TO PANEL TO REMAIN. 10 PROVIDE FIRE ALARM CONNECTION TO DUCT SMOKE DETECTOR FOR HP -B01. DUCT SMOKE DETECTOR PROVIDED WITH UNIT. XX,XXX> INDICATES AVAILABLE FAULT CURRENT NOTE: IF NOT NOTED THE A.F.C. IS UNDER 10,000. REVIEWED .FOR COMPLIANCE WITH NFPA 70 NEC MAY 2 6 2017 City of Tukwila BUILDING DIVISION EXISTING (FOR REFERENCE ONLY) MARK CONDUIT °NUMBER &: SIZE CU: CONDUCTORS PER CONDUIT 2 QUANTITY 4: 4 4 4 SIZE :.#350 MCM #350 MCM. #3/0 XHHW .XHHW 4o, 3. 1 2" .4 #50O .MGM 1" 4 t 2" 1" .•n2/0 #'4 WED )t{" KWit AN5. 2017 PPERi'ENTE 1 1/2" #1 TNWN THWN • R 3 r,. THWN 2" 4 #3/0 THWN 1 1/2" 3 #1 THWN 2"_ 1" 4 4 ##4.. THWN XHHW 1" 4 #6 XHHW 1" 3 #12 THWN . • 1". 4 THWN 1" 3 0 THWN rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 r = 41111.. litx TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com LL z� Z 2p W ©C W Z W Wco 1 wa, 0 0 Zg. vJ M 0 (f) �F- w 0 V N o rn J CN- o l- o -o-co 0 c3)o cn ma) c`tp W d- H 1-11:j REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title POWER ONE -LINE DIAGRAM Drawing Number CE5.01 CE5.01_POWER ONE -LINE DIAGRAM.DWG Z: N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC' EXIST PANEL MDP LOCATION: SERVING: FED FROM: CUSTODIAL STORAGE D108 480/277 VOLT 1200 AMP BUS RATING SCCR: EXISTING 3 PHASE 1200 AMP MAIN BREAKER .AFC: 4 WIRE MOUNTING: SURFACE EXIST MAIN SWITCHBOARD 'MDP' CKT LOAD DESCRIPTION TYPE KVA MP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 DISTRIBUTION PANELBOARD 'DP' P - - 247.468 - - 600/3 - - A 300/3 - - 226.425 - - P - - PANEL 'LB' 2 3 LIGHTING B 2.060 4 5 B RECEPTACLES C 6 7 PANEL 'LD' P - - 120.365 - - 200/3 - - A C 20/1 200/3 - - 88.529 - - P - - PANEL 'LA' 8 9 S B 20/1 10 11 RECEPTACLES 20/1 C 12 13 PANEL 'LC' P - - 131.576 - - 200/3 - - A 20/1 0.900 100/3 - - 41.506 - - •P - - STANDBY TRANSFER SWITCH PANEL ('PX') 14 15 10 B LIGHTING 16 17 20/1 1.600 C 18 19 SPACE S - - A LT - ROOM A113a L - - S SPACE 20 30/3 - - 8.760 - - M - - AHU-A01 14 15 SPARE S - 20/1 1.600 PHASE LOAD PHASE A= 328.38 KVA PHASE B= 316.06 KVA PHASE C= 299.96 KVA 20/1 60/3 - - 30.750 - - LOAD TYPE L R M H WH 20/1 D A K LM TOTAL LOADS PANEL MDP CU -A01 20 21 SPARE S - 20/1 RECEPTACLES B 0.720 KVA AMP PANELBOARD 'DP 32.59 29.46 122.58 D 1.68 C 57.57 3.60 SPARE 53.52 247.47 KVA 297.66 AMP XFMR'TD' (PNL'LD') 12.61 20.90 58.24 1.90 M - - R/E-A01 23.12 3.60 SPARE 30.00 120.37 KVA 144.78 AMP XFMR 'TC'(PNL 'LC') 13.04 16.02 58.82 0.70 SPARE S 38.20 4.80 A 30.00 131.58 KVA 158.26 AMP XFMR 'TB' (PNL'LB') 14.88 8.28 142.83 1.00 1.68 28 4.50 20/1 53.26 53.02 226.43 KVA 272.35 AMP XMFR'TA' (PNL'LA') 7.93 10.98 39.44 1.10 1.68 B 18.00 9.40 0.500 22.77 88.53 KVA 106.48 AMP TRANS SW (PNL'PX') SPACE S 6.89 - RECEPTACLES 32 32.14 2.48 0.555 3.00 41.51 KVA 49.92 AMP CONN. LOAD 81.04 85.64 428.79 4.70 5.04 34 173.53 23.88 53.26 53.52 855.87 KVA 1,029.45 AMP CALC. LOAD 101.30 47.82 428.79 4.70 5.04 0.100 173.53 23.88 53.26 13.38 851.69 KVA 1,024.42 AMP R NOTES: BOLD TEXT INDICATES NEWWORK TO BE PROVIDED TO EXISTING MAIN DISTRIBUTION. 38 39 H-1 H EXIST PANEL LASERVING: LOCATION: FED FROM: ELECTRICAL CLOSET A116 480/277 VOLT 200 AMP BUS RATING SCCR: 14,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: FLUSH EXIST MAIN SWITCHBOARD 'MDP' CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 2.830 20/1 A 20/2 - 1.400 - L - LIGHTING 2 3 LIGHTING L 2.060 20/1 0.720 B RECEPTACLES 4 5 LIGHTING L 1.330 20/1 0.720 R C 20/1 - S SPARE 6 7 SPARE S - 20/1 A R RECEPTACLES 20/1 - S SPARE 8 9 SPARE S - 20/1 0.900 B RECEPTACLES 20/1 - S SPARE 10 11 LIGHTING L 0.235 20/1 1.600 D C 20/1 - S SPARE 12 13 LT - ROOM A113a L 0.074 20/1 A D COMPUTER 30/3 - - 8.760 - - M - - AHU-A01 14 15 SPARE S - 20/1 1.600 B COMPUTER 16 17 SPARE S - 20/1 60/3 - - 30.750 - - C 18 19 SPARE S - 20/1 A R 0.720 40/3 - - 22.770 - - M - - CU -A01 20 21 SPARE S - 20/1 RECEPTACLES B 0.720 22 23 SPARE S - 20/1 D LAMINATOR C 24 25 SPARE S - 20/1 A C 20/1 20/3 - - 3.795 - - M - - R/E-A01 26 27 SPARE S - 20/1 B B 20/1 28 29 SPARE S - 20/1 A 1.000 C 30 31 SPACE S - - A 28 29 20/1 1.055 M FIT -A01, A02, A03 32 33 SPACE S - - EF -A01 B 31 20/1 0.500 M FIT -A04, A05, A07 34 35 SPACE S - - RECEPTACLES 32 C 20/1 0.555 M FIT -A06, A08 36 37 TRANSFORMER 'TA' (PANEL 'PA) P -- 43.165 - 70/3 - A 34 35 30/3 - 0.000 - D - - SURGE SUPPRESSOR 38 39 C B 37 40 41 0.100 20/1 C 42 154.86 KVA 20/1 0.720 R RECEPTACLES 38 39 H-1 H 1.000 20/1 PHASE LOAD PHASE A= 28.87 KVA PHASE B= 30.62 KVA PHASE C= 29.04 KVA 40 41 PMP -A01 LOAD TYPE L R M H WH 20/1 D A K LM TOTAL LOADS PANEL LA 7.93 4.50 37.44 53.26 53.02 226.43 KVA 0.00 CALC. LOAD 18.60 , 22.77 45.36 KVA 54.56 AMP XFMR 'TA (PNL'PA) KVA PHASE C= 10.98 2.01 1.10 1.68 243.40 KVA 18.00 9.40 R 1.13 43.17 KVA 51.92 AMP CONN. LOAD 7.93 10.98 39.44 1.10 1.68 CONN. LOAD 18.00 9.40 2.01 22.77 88.53 KVA 106.48 AMP CALC. LOAD 9.91 10.49 39.44 1.10 1.68 CALC. LOAD 18.00 9.40 2.01 5.69 95.71 KVA 115.13 AMP 18.00 NOTES: BOLD TEXT INDICATED NEW WORK TO BE PROVIDED TO EXISTING PANEL. NEW CIRCUIT 13 IS ADDED. . 0.28 CU -A01 INDICATED ON CIRCUITS 20, 22, 24. . 119.23 AMP EXIST PANEL PA LOCATION: SERVING: FED FROM: ELECTRICAL CLOSET A116 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: FLUSH PANEL 'LA' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 SURGE SUPRESSOR D -- -- 0.000 30/3 - - A 20/1 1.600 D COMPUTER 2 3 LIGHTING B 3.150 20/1 0.720 R RECEPTACLES 4 5 LIGHTING L C 20/1 0.720 R RECEPTACLES 6 7 COMPUTER D 1.600 20/1 A EF -B03 6 20/1 0.720 R RECEPTACLES 8 9 COMPUTER D 1.600 20/1 S B 8 20/1 0.900 R RECEPTACLES 10 11 COMPUTER D 1.600 20/1 13 LTG-CAFETERIAEXPANSION C 20/1 1.600 D COMPUTER 12 13 RECEPTACLES R 0.720 20/1 A LTG - EXIT L 20/1 1.600 D COMPUTER 14 15 COMPUTER D 1.600 20/1 20/1 B 14 20/1 1.600 D COMPUTER 16 17 RECEPTACLES R 0.720 20/1 60/3 - - 30.750 - - C 20/1 0.720 R RECEPTACLES 18 19 RECEPTACLES R 0.720 20/1 A 24 25 20/1 0.720 R RECEPTACLES 20 21 RECEPTACLES R 0.720 20/1 MUA-B01 B 27 20/1 1.200 D LAMINATOR 22 23 RECEPTACLES R 0.720 20/1 TRANSFORMER 'TK (PANEL 'K) P - - C 20/1 1.200 D LAMINATOR 24 25 VENDING MACHINE A 1.000 20/1 A B 24 20/1 1.200 D COPY MACHINE 26 27 VENDING MACHINE A 1.000 20/1 50/3 - - B 26 20/1 0.900 R REC - ROOMS A113, A113a 28 29 REFRIGERATOR A 1.200 20/1 40 41 C 20/1 0.680 M EF -A01 30 31 MICROWAVE A 1.200 20/1 A SPACE 30 20/1 0.540 R RECEPTACLES 32 33 COMP -A01 M 1.125 20/1 S B L 30/2 - 5.000 - A - WASHER/DRYER 34 35 WH -A01 WH 1.680 20/1 PANEL LB 14.88 C 36 37 UH -A01 H 0.100 20/1 A 53.02 154.86 KVA 20/1 0.720 R RECEPTACLES 38 39 H-1 H 1.000 20/1 53.26 B 55.50 KVA 20/1 0.720 R RECEPTACLES 40 41 PMP -A01 M 0.200 20/1 B 1.13 C 20/1 1.600 D COMPUTER 42 1.00 1.68 C 4.50 D 53.26 53.02 226.43 KVA 272.35 AMP CALC. LOAD 18.60 PHASE LOAD PHASE A= 12.44 KVA PHASE B= 15.59 KVA PHASE C= 15.14 KVA 53.26 13.25 243.40 KVA LOAD TYPE L R M H WH R D A K LM TOTAL LOADS CONN. LOAD K 10.98 2.01 1.10 1.68 6.84 18.00 9.40 1.68 1.13 43.17 KVA 119.81 AMP CALC. LOAD 1.13 10.49 2.01 1.10 1.68 6.84 18.00 9.40 1.68 0.28 42.96 KVA . 119.23 AMP NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. LOAD ADDED TO EXISTING CIRCUIT 28. 45.40 AMP NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. CIRCUITS 31 & 33 ADDED. EXIST PANEL LB LOCATION: SERVING: FED FROM: P.E. OFFICE/STORAGE B109 480/277 VOLT 400 AMP BUS RATING SCCR: 14,000 A 3 PHASE 300 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: FLUSH EXIST MAIN SWITCHBOARD' MDP' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE MP KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 3.150 20/1 A 20/3 - - 6.045 -- -- M AHU-B01 2 3 LIGHTING L 3.150 20/1 B 4 5 LIGHTING L 3.885 20/1 RECEPTACLES R C 6 7 LIGHTING L 1.520 20/1 A EF -B03 6 30/3 - - 11.160 - - M - - AHU-B02 8 9 LIGHTING L 1.710 20/1 S B 8 10 11 SPARE S - 20/1 B C 12 13 LTG-CAFETERIAEXPANSION L 1.408 20/1 A 0.900 20/1 40/3 - - 21.855 - - M - - CU -B01 14 15 LTG - EXIT L 0.060 20/1 R B 20/1 16 17 SPARE S - 20/1 SPARE 14 C 18 19 R/E-B01 M - - 2.295 - - 20/3 - - A 20/1 - 60/3 - - 30.750 - - M - - CU -B02 20 21 0.180 B 0.720 22 23 20/1 - C 24 25 R/E-B01 M - - 8.760 - - 30/3 - - A A 30/2 - 20/3 - - 3.795 - - M - MUA-B01 26 27 21 B S 28 29 - B C 30 31 TRANSFORMER 'TK (PANEL 'K) P - - 55.495 - - 100/3 - - A D 0.500 20/3 - - 2.295 - - M - - EF -B01 32 33 S B 24 34 35 S - C 36 37 TRANSFORMER 'TB' (PANEL 'PB') P - - 16.075 - - 50/3 - - A 26 27 80/3 - - 53.017 - - M - - HP B01 38 39 20/1 B - 40 41 28 29 C 42 - 20/1 S - C - - S SPACE 30 31 PHASE LOAD PHASE A= 76.78 KVA PHASE B= 75.97 KVA PHASE C= 73.67 KVA - - S LOAD TYPE L R M H WH 20/1 D A K LM TOTAL LOADS PANEL LB 14.88 34 139.97 SPARE S - 20/1 S - 53.02 154.86 KVA 186.26 AMP XFMR'TK (PNL'K) SPACE 1.44 37 H-3 H 1.000 0.80 A 53.26 CALC. LOAD 55.50 KVA 66.75 AMP XFMR'PB' (PNL'PB') SURGE SUPPRESSOR 6.84 2.86 1.00 1.68 1.680 3.70 KVA PHASE C= B 1.13 16.08 KVA 19.34 AMP CONN. LOAD 14.88 8.28 142.83 1.00 1.68 C 4.50 D 53.26 53.02 226.43 KVA 272.35 AMP CALC. LOAD 18.60 8.28 142.83 1.00 1.68 PHASE LOAD PHASE A= 4.50 KVA PHASE B= 53.26 13.25 243.40 KVA 292.76 AMP CALC. LOAD NOTES: BOLD TEXT INDICATES NEWWORK TO EXISTING PANEL. NEW CIRCUITS 13 & 15 ADDED. CU -B01 AND CU -B02 INDICATED. 1.44 LOAD TYPE REMOVE EXISTING SPARE 3013P BREAKER FROM 38,40,42 AND PROVIDE NEW 80/3P BREAKER AS SHOWN. R EXIST PANEL PB LOCATION: SERVING: FED FROM: P.E. OFFICE/STORAGE B109 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 60 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: FLUSH PANEL 'LB' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RECEPTACLES R 0.720 20/1 A 20/1 0.600 M FC -B01 2 3 RECEPTACLES R 0.720 20/1 B 20/1 0.100 M EF -B04 4 5 RECEPTACLES R 0.720 20/1 7 VENTILATOR C 20/1 0.830 M EF -B03 6 7 COMPUTER D 1.600 20/1 A COLD SERVING UNIT K 20/1 - S SPARE 8 9 COMPUTER D 1.600 20/1 20/1 B 20/1 - S SPARE 10 11 RECEPTACLES R 0.900 20/1 20/3 - - - - - C 20/1 1.125 M EF -B02 12 13 RECEPTACLES R 0.900 20/1 A 17 SPARE 20/1 - S SPARE 14 15 RECEPTACLES R 0.900 20/1 0.800 B A 20/1 - S SPARE 16 17 RECEPTACLES R 0.180 20/1 0.720 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 30/2 - 2.760 - 20/1 - S SPARE 20 21 SPARE S - 20/1 - B 27 20/1 - S SPARE 22 23 SOUND SYSTEM D 0.500 20/1 HOT SERVING UNIT 28 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A - 20/1 - - S SPACE 26 27 SPARE S - 20/1 S B 20/1 - - S SPACE 28 29 SPARE S - 20/1 S - C - - S SPACE 30 31 REC - CAFETERIA EXPANSION R 0.900 20/1 A - - - - S SPACE 32 33 REC-CAFETERIAEXPANSION R 0.900 20/1 S B - - - S SPACE 34 35 SPARE S - 20/1 S - C - - S SPACE 36 37 H-3 H 1.000 20/1 A 99.65 AMP CALC. LOAD 30/3 - - 0.000 - - D - - SURGE SUPPRESSOR 38 39 WH -B01 WH 1.680 20/1 KVA PHASE C= B KVA 40 41 PMP -B01 M 0.200 20/1 M H C 42 D A K LM TOTAL LOADS CONN. LOAD 1.44 0.00 PHASE LOAD PHASE A= 5.72 KVA PHASE B= 5.90 KVA PHASE C= 4.46 KVA CALC. LOAD 1.44 LOAD TYPE L R M H WH 34.62 D A K LM TOTAL LOADS CONN. LOAD 38.20 6.84 2.86 1.00 1.68 NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. EXISTING CIRCUITS 1,3 & 14,16,18 TO BE RELOCATED TO NEW PANEL PX1. 3.70 16.29 EXISTING 200 AMP MAIN SHUNT TRIP BREAKER FOR PANEL K IS LOCATED IN PE OFFICE/STORAGE ROOM 109. 1.13 16.08 KVA 44.62 AMP CALC. LOAD 38.20 6.84 2.86 1.00 1.68 167.58 AMP 3.70 NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -001 LOCATION IN PANEL. 0.28 16.36 KVA 45.40 AMP NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. CIRCUITS 31 & 33 ADDED. EXIST PANEL K LOCATION: SERVING: FED FROM: KITCHEN B107 208/120 VOLT 250 AMP BUS RATING SCCR: 10,000 A 3 PHASE 200 AMP SHUNT -TRIP BKR AFC: 4 WIRE MOUNTING: FLUSH PANEL 'LB' CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 80/3 - - 22.995 - - K - - CONVECTION OVEN 2 3 SPARE S - 20/1 B 4 5 MILK DISPENSER K 0.660 20/1 COMPUTER D C 6 7 VENTILATOR K 0.480 20/1 A RECEPTACLES 6 80/3 - - 15.000 - - K - - DISHWASHING MACHINE 8 9 COLD SERVING UNIT K 0.500 20/1 D B 8 10 11 HOT CABINET K 1.900 20/1 B C 12 13 CASHIER'S STAND K 0.400 20/1 A 0.900 20/1 20/3 - - - - - S - - SPARE 14 15 MILK DISPENSER K 0.660 20/1 D B 20/1 16 17 SPARE S - 20/1 RECEPTACLES 14 C 18 19 COMPUTER D 0.800 20/1 A 20/1 0.720 40/2 - 5.200 - K - HOT PLATE 20 21 RECEPTACLE R 0.720 20/1 C B 0.720 22 23 RECEPTACLE R 0.720 20/1 SPARE S C 30/2 - 2.760 - K - DISPOSER 24 25 SPARE S - 20/1 A S - 26 27 SPARE S - 20/1 M B 26 30/2 - 2.700 - K - HOT SERVING UNIT 28 29 SPARE S - 20/1 S SPACE C 30 31 SPARE S - 20/1 A C - - - S SPACE 32 33 SPARE S - 20/1 20/1 B - - - S SPACE 34 35 SPARE S - 20/1 B 0.900 C - - S SPACE 36 37 SPACE S - - A C - - - S SPACE 38 39 SPACE S - - LOAD TYPE B 30/3 - - - - S SPACE 40 41 SPACE S - - CALC. LOAD 9.90 C - - S SPACE 42 4.80 35.90 KVA 99.65 AMP CALC. LOAD 9.90 PHASE LOAD PHASE A= 48.34 KVA PHASE B= 43.71 PHASE LOAD PHASE A= 18.33 KVA PHASE B= 18.50 KVA PHASE C= 18.68 KVA L R M LOAD TYPE L R M H WH LM D A K LM TOTAL LOADS CONN. LOAD 1.44 0.00 30.00 0.80 83.96 AMP 53.26 55.50 KVA 154.04 AMP CALC. LOAD 1.44 38.20 4.80 0.70 0.80 74.31 AMP 34.62 -13.04 36.86 KVA 102.30 AMP REQUIRED PANEL SKIRTS 38.20 4.80 OPTIONS: 30.00 131.58 KVA NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. EXISTING CIRCUITS 1,3 & 14,16,18 TO BE RELOCATED TO NEW PANEL PX1. CALC. LOAD 16.29 EXISTING 200 AMP MAIN SHUNT TRIP BREAKER FOR PANEL K IS LOCATED IN PE OFFICE/STORAGE ROOM 109. 58.82 EXIST PANEL LC LOCATION: SERVING: FED FROM: BLDG. C CORRIDOR 480/277 VOLT 200 AMP BUS RATING SCCR: 14,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: FLUSH EXIST MAIN SWITCHBOARD' MDP' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AVP KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 3.660 20/1 A 40/3 - - 16.680 - M - - AHU-001 2 3 LIGHTING L 2.270 20/1 B 4 5 LIGHTING L 3.660 20/1 COMPUTER D C 6 7 LIGHTING L 1.620 20/1 A RECEPTACLES 6 50/3 - - 30.000 - - M - - CU -001 8 9 LIGHTING L 1.235 20/1 D B 8 10 11 LIGHTING L 0.590 20/1 B C 12 13 SPARE S - 20/1 A 0.900 20/1 20/3 - 6.045 - - M - - R/E-001 14 15 SPARE S - 20/1 D B 20/1 16 17 SPARE S - 20/1 RECEPTACLES 14 C 18 19 SPARE S - 20/1 A 20/1 0.720 20/1 1.165 M FIT -008, C09, C10 20 21 SPARE S - 20/1 C B 0.720 20/1 1.165 M FIT -001, CO2, CO3 22 23 SPARE S - 20/1 20/1 C 20/1 1.110 M FIT -004, C05, 006, C07 24 25 SPARE S - 20/1 A 20/1 1.600 20/1 0.600 M FC -001, CO2 26 27 SPARE S - 20/1 C B 0.900 - - S SPACE 28 29 SPARE S - 20/1 SURGE SUPPRESSOR 20/1 C - - S SPACE 30 31 SPACE S - - A 20/1 0.900 - - S SPACE 32 33 SPACE S - - C B 0.900 - - S SPACE 34 35 SPACE S - - C - - S SPACE 36 37 TRANSFORMER'TC' (PANEL 'PC' SECTION 1 & 2) P - - 61.776 - - 100/3 - - A LOAD TYPE L 30/3 - - 0.000 - - D - - SURGE SUPPRESSOR 38 39 A B LM 40 41 CALC. LOAD 9.90 C 42 0.70 26.00 12.20 4.80 35.90 KVA 99.65 AMP CALC. LOAD 9.90 PHASE LOAD PHASE A= 48.34 KVA PHASE B= 43.71 KVA PHASE C= 39.54 KVA 35.90 KVA 99.65 AMP LOAD TYPE L R M H WH D A K LM TOTAL LOADS PANEL LC 13.04 56.77 0.00 30.00 69.80 KVA 83.96 AMP PNL 'PC' SEC 1 & 2 16.02 2.06 0.70 38.20 4.80 0.70 61.78 KVA 74.31 AMP CONN. LOAD -13.04 16.02 58.82 0.70 38.20 4.80 30.00 131.58 KVA 158.26 AMP CALC. LOAD 16.29 13.01 58.82 0.70 38.20 4.80 7.50 139.32 KVA 167.58 AMP NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -001 LOCATION IN PANEL. EXIST PANEL PC SEC 1 LOCATION: SERVING: FED FROM: BLDG. C CORRIDOR 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: FLUSH LC CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 COMPUTER D 1.600 20/1 A 20/1 0.720. R RECEPTACLES 2 3 COMPUTER D 1.600 20/1 B • 20/1 0.720 R RECEPTACLES 4 5 COMPUTER D 1.600 20/1 C 20/1 0.720 R RECEPTACLES 6 7 COMPUTER D 1.600 20/1 A 20/1 1.600 D COMPUTER 8 9 COMPUTER D 1.600 20/1 B 20/1 1.600 D COMPUTER 10 11 RECEPTACLES R 0.900 20/1 C 20/1 1.600 D COMPUTER 12 13 COMPUTER D 1.200 20/1 A 20/1 0.900 R RECEPTACLES 14 15 COMPUTER D 1.200 20/1 B 20/1 0.720 R RECEPTACLES 16 17 COMPUTER D 1.200 20/1 C 20/1 0.720 R RECEPTACLES 18 19 RECEPTACLES R 0.900 20/1 A 20/1 1.600 D COMPUTER 20 21 RECEPTACLES R 0.900 20/1 B 20/1 1.600 D COMPUTER 22 23 COMPUTER D 1.600 20/1 - S C 20/1 0.900 R RECEPTACLES 24 25 COMPUTER D 1.600 20/1 A D - - SURGE SUPPRESSOR 20/1 0.800 D COMPUTER 26 27 COMPUTER D 0.800 20/1 59 B H 20/1 0.900 R RECEPTACLES 28 29 COMPUTER D 1.600 20/1 C 20/1 0.900 R RECEPTACLES 30 11.20 KVA PHASE B= 9.82 KVA PHASE C= 4.86 KVA LOAD TYPE L PHASE LOAD PHASE A= 12.52 KVA PHASE B= 11.64 KVA PHASE C= 11.74 KVA K LM TOTAL LOADS LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD CALC. LOAD 9.90 6.12 2.06 0.70 26.00 12.20 4.80 35.90 KVA 99.65 AMP CALC. LOAD 9.90 CIRCUIT 45 RELOCATED TO NEW PANEL PX3. CIRCUIT 40 TO BECOME GENERAL PURPOSE RECEPTACLE. 26.00 35.90 KVA 99.65 AMP • REQUIRED FEED-THRU LUGS _ - EVEWE OPTIONS: NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. COMPLIANC = NFPA °7Q FOR WITH H NEC 017 City of Tukwila ISION EXIST PANEL PC SEC 2 LOCATION: SERVING: FED FROM: BLDG. C CORRIDOR 208/120 VOLT 250 AMP MAIN LUGS ONLY S I c.ove1...., . A ...-- s 3 PHASE AFC: 4 WIRE MOUNTING: FLUSH LC CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 31 COMPUTER D 1.600 20/1 A 20/1 1.080 R RECEPTACLES 32 33 COMPUTER D 0.800 20/1 B 20/1 1.080 R RECEPTACLES 34 35 EF -001 M 0.680 20/1 C 20/1 0.900 R RECEPTACLES 36 37 GIRLS HAND DRYER NORTH A 1.200 20/1 A 20/1 0.696 M KILN FAN 38 39 GIRLS HAND DRYER SOUTH A 1.200 20/1 B 20/1 0.360 R RECEPTACLE 40 41 RECEPTACLES R 1.260 20/1 C 20/1 - S SPARE 42 43 FC -0O2 H 0.600 20/1 A 20/1 0.800 D COMPUTER RECG:: 4 E 45 SPARE S - 20/1 B 20/1 1.200 A BOYS HAND DRYER SOUD-1TV OF -134/114 47 RECEPTACLE R 0.720 20/1 C ' 20/1 1.200 A BOYS HAND DRYER NORTH 8 49 RECEPTACLE R 0.720 20/1 A 60/2 - 9.000 - D - APR KILN p'�e"'�t i S-4�f1 2 0 /' 51 SPARE S - 20/1 B Oa [ V'� 53 SPARE S - 20/1 C - - S SPACE 54 55 SPACE S- - A 30/3 - - 0.000 - - D - - SURGE SUPPRESSOR 56 57 EF -0O2 M 0.680 20/1 B 58 59 UH -001 H 0.100 20/1 C 60 PHASE LOAD PHASE A= 11.20 KVA PHASE B= 9.82 KVA PHASE C= 4.86 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 6.12 2.06 0.70 12.20 4.80 0.70 25.88 KVA 71.82 AMP CALC. LOAD 6.12 2.06 0.70 12.20 4.80 0.17 26.05 KVA 72.31 AMP NOTES: BOLD TEXT INDICATES CHANGES TO EXISTING PANEL. CIRCUIT 45 RELOCATED TO NEW PANEL PX3. CIRCUIT 40 TO BECOME GENERAL PURPOSE RECEPTACLE. D WIL/, 017 TER architects rollu a architecture planning interior design. 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222. f: 206-624-4226 v V TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com LL zV , LtJ Z 2 0 J F w <C W Z Wco co W 00 z VJ = M <C U §- g O u) ILA, WA 98168 O O oM 0 O) N LU J Q H F- -mac REVISION DATE Design: FLR Drawn: BT Checked: FLR Project No. Issuance PERMIT SET Date: 4/14/2017 Drawing Title PANEL SCHEDULES Drawing Number CE5.02 CE5.02_PANEL SCHEDULES.DWG ti CV N COPYRIGHT 0 2015 ROLLUDA ARCHITECTS INC EXIST PANEL LD LOCATION: FED CUSTODIAL STORAGE D108 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: FROM: EXIST MAIN SWITCHBOARD' MDP' CKT CKT LOAD DESCRIPTION TYPE KVA MP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 3.600 20/1 A 20/1 40/3 - - 16.680 - - M - - AHU-D01 2 3 LIGHTING L 2.595 20/1 B B 20/1 4 5 LIGHTING L 3.600 20/1 D 0.900 C 6 7 LIGHTING L 1.120 20/1 A 6 7 50/3 - - 30.000 - - M - - CU -D01 8 9 LIGHTING L 1.045 20/1 RECEPTACLES B 9 10 11 LIGHTING L 0.650 20/1 B 20/1 C 12 13 SPARE S - 20/1 A 20/1 20/1 20/3 - - 6.045 - - M - - R/E-D01 14 15 SPARE S - 20/1 1.600 B A 16 17 SPARE S - 20/1 14 15 C 18 19 SPARE S - 20/1 A 1.600 R 20/1 1.440 M FIT -D07, D08, D09 20 21 SPARE S - 20/1 20/1 B R 20/1 1.165 M FIT -D01, D02, D03 22 23 SPARE S - 20/1 20/1 0.540 C 20/1 0.945 M FIT -D04, D05, D06 24 25 SPARE S - 20/1 A 0.720 D 20/1 0.600 M FC -D01, D02 26 27 SPARE S - 20/1 20/1 B R - - S SPACE 28 29 SPARE S - 20/1 20/1 0.720 C - - S SPACE 30 31 SPACE S - - A 0.720 R - - S SPACE 32 33 SPACE S - - 20/1 B R - - S SPACE 34 35 SPACE S - - 4.42 KVA PHASE C= C - - S SPACE 36 37 SURGE SUPPRESSOR D -- -- 0.000 30/3 - - A L R 100/3 - - 50.880 - - P - - TRANSFORMER' TD' (PANEL 'PD SECTION 1 & 2) 38 39 K B TOTAL LOADS 40 41 15.50 KVA C 42 40.69 AMP 20.72 6.89 5.40 1.36 36.22 KVA 100.54 AMP CALC. LOAD 2.40 12.75 41.51 KVA PHASE LOAD PHASE A= 42.78 KVA PHASE B= 38.58 KVA PHASE C= 39.01 KVA 33.47 KVA 92.90 AMP REQUIRED LOAD TYPE L R M H WH KVA PHASE C= D A K LM TOTAL LOADS PANEL LD 12.61 0.75 56.88 50.83 AMP WH NOTES: 0.00 A K 30.00 69.49 KVA 83.58 AMP PNL'PD' SEC 1 & 2 20.90 1.36 1.90 13.78 23.12 3.60 3.00 0.68 50.88 KVA 61.20 AMP CONN. LOAD 12.61 20.90 58.24 1.90 13.56 23.12 3.60 2.18 30.00 120.37 KVA 144.78 AMP CALC. LOAD 15.76 15.45 58.24 1.90 4.80 23.12 3.60 7.50 125.57 KVA 151.03 AMP NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -D01 LOCATION IN PANEL. 6.89 EXIST PANEL PD SEC 1 LOCATION: SERVING: FED FROM: CUSTODIAL STORAGE D108 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: PANEL 'LD' PANEL 'PX' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 COMPUTER D 1.600 20/1 A A 20/1 1.600 R COMPUTER 2 3 COMPUTER D 1.600 20/1 20/1 B B 20/1 1.600 R COMPUTER 4 5 RECEPTACLES D 0.900 20/1 20/1 SPARE C 20/1 0.540 R RECEPTACLES 6 7 RECEPTACLES D 0.900 20/1 A A S 20/1 0.900 D RECEPTACLES 8 9 RECEPTACLES D 0.720 20/1 20/1 B B 20/1 0.720 D RECEPTACLES 10 11 COMPUTER R 1.600 20/1 20/1 SPARE C 20/1 1.600 D COMPUTER 12 13 COMPUTER D 1.600 20/1 A A S 20/1 1.600 R COMPUTER 14 15 COMPUTER D 1.600 20/1 20/1 B B 20/1 1.600 R COMPUTER 16 17 RECEPTACLES D 0.900 20/1 20/1 SPARE C 20/1 0.540 R RECEPTACLES 18 19 RECEPTACLES R 0.900 20/1 A A S . 20/1 0.540 D RECEPTACLES 20 21 COMPUTER R 1.600 20/1 20/1 B B 20/1 0.720 D RECEPTACLES 22 23 COMPUTER D 1.600 20/1 20/1 SPARE C 20/1 1.600 R COMPUTER 24 25 COMPUTER D 1.600 20/1 A A S 20/1 0.720 D RECEPTACLES 26 27 RECEPTACLES D 0.900 20/1 1.200 B S 20/1 0.720 R RECEPTACLES 28 29 COMPUTER D 1.600 20/1 C - C 20/1 1.600 R COMPUTER 30 SPACE 32 33 PHASE LOAD PHASE A= PHASE LOAD PHASE A= 6.48 KVA PHASE B= 4.42 KVA PHASE C= 3.76 PHASE LOAD PHASE A= 11.96 KVA PHASE B= 11.78 KVA PHASE C= 12.48 KVA M H WH LOAD TYPE L R M H WH CONN. LOAD D A K LM TOTAL LOADS CONN. LOAD 2.40 15.50 KVA 0.68 14.66 KVA 40.69 AMP 20.72 6.89 5.40 1.36 36.22 KVA 100.54 AMP CALC. LOAD 2.40 12.75 41.51 KVA 0.17 14.83 KVA 41.16 AMP 20.72 NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. 33.47 KVA 92.90 AMP REQUIRED OPTIONS: FEED-THRU LUGS 41.51 KVA 49.92 AMP OPTIONS: 13.97 KVA PHASE C= NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. KVA 32.14 EXIST PANEL PD SEC 2 LOCATION: FED CUSTODIAL STORAGE D108 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: FROM: PANEL 'LD' PANEL 'PX' CKT LOAD DESCRIPTION LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 31 COMPUTER D 1.600 20/1 A 100/3 - - 20/1 1.080 R RECEPTACLES 32 33 COMPUTER D 0.800 20/1 B B 4 20/1 1.200 A BOYS HAND DRYER SOUTH 34 35 RECEPTACLES R 0.720 20/1 SPARE S C 20/1 - S SPARE 36 37 RECEPTACLES R 0.720 20/1 A S - 20/1 1.200 A BOYS HAND DRYER NORTH 38 39 EF -D02 M 0.680 20/1 SPARE B - 20/1 - S SPARE 40 41 RECEPTACLES R 1.260 20/1 SPARE S C 20/1 0.600 H FC -D02 42 43 EF -D01 M 0.680 20/1 A S - 20/1 - S SPARE 44 45 SPARE S - 20/1 SPARE B - 20/1 - S SPARE 46 47 SPARE S - 20/1 SPARE S C 20/1 0.360 R RECEPTACLES 48 49 GIRLS HAND DRYER NORTH A 1.200 20/1 A S . - - - S SPACE 50 51 RECEPTACLES R 0.540 20/1 SPARE B - - - S SPACE - 52 53 RECEPTACLES R 0.720 20/1 SPARE S C - - S SPACE 54 55 SPARE S - 20/1 A S - 30/3 - - 0.000 - - D - - SURGE SUPPRESSOR A 56 58 57 GIRLS HAND DRYER SOUTH H 1.200 20/1 S B 20/1 60 59 UH -D01 H 0.100 20/1 SPACE 30 C - A 30 - - - S SPACE 32 33 PHASE LOAD PHASE A= PHASE LOAD PHASE A= 6.48 KVA PHASE B= 4.42 KVA PHASE C= 3.76 KVA S LOAD TYPE L LOAD TYPE L R M H WH A D A K LM TOTAL LOADS CONN. LOAD 37 5.40 1.36 1.90 60/3 - - A 2.40 3.60 KVA 0.68 14.66 KVA 40.69 AMP CALC. LOAD 6.89 5.40 1.36 1.90 32.14 2.48 2.40 3.60 41.51 KVA 0.17 14.83 KVA 41.16 AMP 16.29 KVA NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. INTEGRAL SPD CIRCUIT 45 & 47 RELOCATED TO NEW PANEL PX1. CIRCUIT 48 TO BECOME GENERAL PURPOSE RECEPTACLE. 2.48 NEW PANEL PX LOCATION: SERVING: FED FROM: MAIN ELECTRICAL ROOM D108 480/277 VOLT 125 AMP BUS RATING SCCR: 14,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE XFMR-TX BUILDINGS B & D PANEL 'PX' CKT LOAD DESCRIPTION TYPE KVA NP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A A 100/3 - - 41.506 - - P - - XFMR-TX/PANEL 'PX1' 2 3 SPARE S - 20/1 20/1 B B 4 5 SPARE S - 20/1 5 F.A POWER SUPPLY RM D115 C 6 7 SPARE S - 20/1 A ACCESS CONTROL PNLS RMM D115 D - - S SPACE 8 9 SPARE S - 20/1 9 B S - - S SPACE 10 11 SPARE S - 20/1 11 SPARE C - - S SPACE 12 13 SPARE S - 20/1 A SECURITY PANEL ROOM D108 D - - S SPACE 14 15 SPARE S - 20/1. 15 B D - - S SPACE 16 17 SPARE S - 20/1 20/1 MDF AIR COND. UNIT RM E135 C - - S SPACE 18 19 SPARE S - 20/1 A - S - - S SPACE 20 21 SPARE S . - 20/1 - B S - - S SPACE 22 23 SPARE S - 20/1 - - C - - S SPACE 24 25 SPARE S - 20/1 A - S - - S SPACE 26 27 SPARE S - 20/1 - B S - - S SPACE 28 29 SPARE S - 20/1 - - C - - S SPACE 30 - - A 30 - - - S SPACE 32 33 PHASE LOAD PHASE A= 16.96 KVA PHASE B= 13.97 KVA PHASE C= 10.59 KVA - - S LOAD TYPE L R M H WH - D A K LM TOTAL LOADS PANEL PX SPACE 36 37 PANEL 'PX2' ROOM E130 P - - 15.744 - - 60/3 - - A KVA AMP PANEL 'PX1' PANEL'PX3' ROOM C110 38 6.89 CALC. LOAD B 4.80 KVA 32.14 2.48 3.00 41.51 KVA 49.92 AMP CONN. LOAD 0.55 16.29 KVA 6.89 REQUIRED INTEGRAL SPD 32.14 2.48 OPTIONS: 3.00 41.51 KVA 49.92 AMP CALC. LOAD 13.97 KVA PHASE C= 6.89 KVA 32.14 2.48 L 0.75 42.26 KVA 50.83 AMP WH NOTES: D A K LM NEW PANEL PX1 LOCATION: FED MAIN ELECTRICAL ROOM D108 208/120 VOLT 200 AMP BUS RATING SCCR: 22,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE SERVING: FROM: BUILDINGS B & D PANEL 'PX' CKT CKT LOAD DESCRIPTION TYPE KVA A/P PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 IDF-D BLDG ROOM D115 D 1.680 20/1 A 20/1 20/1 0.500 A WALK-IN FREEZER (NEW) 2 3 FIRE/SMOKE DAMPER BLDG D D 1.500 20/1 B B 20/1 20/2 - 1.706 - M - REFRIGERATION SYSTEM (NEW) 4 5 F.A POWER SUPPLY RM D115 D 1.800 20/1 - - - C C 6 7 ACCESS CONTROL PNLS RMM D115 D 1.800 20/1 A 1.800 20/1 20/1 1.176 A REACH -IN FREEZER (EXIST) 8 9 SPARE S - 20/1 D B 20/1 20/1 0.800 A WALK-IN COOLER (EXIST) 10 11 SPARE S - 20/1 D 1.800 C 20/1 - S SPARE 12 13 SECURITY PANEL ROOM D108 D 1.500 20/1 A - 20/1 20/3 - - 3.000 - - M - - REFRIGERATION SYSTEM (EXIST) 14 15 FIRE ALARM PANEL ROOM D108 D 1.500 20/1 S B 20/1 16 17 (2) F.A NAC PANELS RM D108 D 1.500 20/1 MDF AIR COND. UNIT RM E135 16 C 18 19 (2) F.A NAC PANELS RM D108 D 1.500 20/1 A 18 19 - - S SPACE 20 21 GENERATOR OIL PAN HEATER D 0.500 20/1 SPACE B 21 - - S SPACE 22 23 BATTERY CHARGER D 0.500 20/1 SPACE 22 C - - S SPACE 24 25 SPARE S - 20/1 A 24 25 - - S SPACE 26 27 SPARE S - 20/1 SPACE B 27 - - S SPACE 28 29 SPACE S - S SPACE 28 C - - S SPACE 30 31 SPACE S - - A 30 - - - S SPACE 32 33 SPACE S - - PHASE LOAD PHASE A= B KVA PHASE B= - - S SPACE 34 35 SPACE S - - M H C - - S SPACE 36 37 PANEL 'PX2' ROOM E130 P - - 15.744 - - 60/3 - - A 60/3 - - 4.800 - - P - - PANEL'PX3' ROOM C110 38 39 CALC. LOAD B 4.80 KVA 40 41 C 42 0.55 16.29 KVA 45.22 AMP REQUIRED INTEGRAL SPD 13.32 AMP REQUIRED OPTIONS: INTEGRAL SPD PHASE LOAD PHASE A= 16.96 KVA PHASE B= 13.97 KVA PHASE C= 10.59 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS PANEL PX1 4.71 13.78 2.48 3.00 20.96 KVA 58.18 AMP PANEL 'PX2 2.18 13.56 2.18 15.74 KVA 43.70 AMP PANEL'PX3' 4.80 4.80 KVA 13.32 AMP CONN. LOAD 6.89 32.14 2.48 3.00 41.51 KVA 115.21 AMP CALC. LOAD 6.89 32.14 2.48 0.75 42.26 KVA 117.29 AMP REQUIRED INTEGRAL SPD OPTIONS: NOTES: NEW PANEL PX2 LOCATION: FED MECH/ELEC/BOILER ROOM E130 208/120 VOLT 100 AMP BUS RATING SCCR: 22,000 A 3 PHASE 60 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE SERVING: BUILDING E NORTH FROM: PANEL 'PX1' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 REC - MDF RM E135 T.T.B. D 1.440 20/1 A 20/1 1.440 D FIRE/SMOKE DAMPER BLDG. E W. 2 3 REC - MDF RM E135 EC/TV HEAD END D 1.800 20/1 5 B 20/1 1.440 D FIRE/SMOKE DAMPER BLDG. E SO. 4 5 REC - MDF RM E135 D 0.360 20/1 100/3 - - - - - C 20/1 1.680 D REC - IDF-E BLDG E RM E104A 6 7 REC - MDF RM E135 MDF RACK D 1.800 20/1 A 12 13 20/1 - S SPARE 8 9 REC - MDF RM E135 MDF RACK D 1.800 20/1 SPACE B 15 20/1 - S SPARE 10 11 REC - MDF RM E135 MDF RACK D 1.800 20/1 SPACE 16 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 18 19 20/1 - S SPARE 14 15 SPARE S - 20/1 SPACE B 20/2 - 2.184 - M - MDF AIR COND. UNIT RM E135 16 17 SPARE S - 20/1 PHASE LOAD PHASE A= 114.65 C 18 19 SPACE S - - A S - - - S SPACE 20 21 SPACE S - - SPACE B - - - S SPACE 22 23 SPACE S -. - SPACE S C - - S SPACE 24 25 SPACE S - - A S - - - S SPACE 26 27 SPACE S - - SPACE B - - - S SPACE 28 29 SPACE S 28 - SPACE S C - - S SPACE 30 - S SPACE 30 297.66 AMP CALC. LOAD 40.73 19.73 122.58 1.68 PHASE LOAD PHASE A= 4.68 KVA PHASE B= 6.13 KVA PHASE C= 4.93 KVA 1.68 KVA PHASE C= LOAD TYPE L R M H WH R D A K LM TOTAL LOADS CONN. LOAD K LM 2.18 CONN. LOAD 13.56 2.18 15.74 KVA 43.70 AMP CALC. LOAD 4.80 KVA 2.18 CALC. LOAD 13.56 0.55 16.29 KVA 45.22 AMP REQUIRED INTEGRAL SPD 13.32 AMP REQUIRED OPTIONS: INTEGRAL SPD NOTES: OPTIONS: NEW PANEL PX3 LOCATION: SERVING: FED FROM: DATA/STORAGE ROOM C110 208/120 VOLT 100 AMP BUS RATING SCCR: 22,000 A 3 PHASE 60 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE BUILDINGS A, C & E SOUTH PANEL 'PX1' CKT LOAD DESCRIPTION TYPE KVA A/P PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 REC - IDF-A BLDG A D 1.680 20/1 A 20/1 1.440 D FIRE/SMOKE DAMPER BLDG. C 2 3 REC - IDF-C BLDG C D 1.680 20/1 5 B 20/1 - S SPARE 4 5 SPARE S - 20/1 100/3 - - - - - C 20/1 - S SPARE 6 7 SPARE S - 20/1. A 12 13 20/1 - S SPARE 8 9 SPARE S - 20/1 SPACE B 15 20/1 - S SPARE 10 11 SPARE S - 20/1 SPACE 16 C 20/1 - S SPARE 12 13 SPACE S - - A 18 19 - - S .SPACE - 14 15 SPACE S - - SPACE B - - S SPACE 16 17 SPACE S - - PHASE LOAD PHASE A= 114.65 C - - S SPACE 18 19 SPACE S - - A H WH - - S SPACE 20 21 SPACE S - - B - - S SPACE 22 23 SPACE S - - C - - S SPACE 24 25 SPACE S - - A - - S SPACE 26 27 SPACE S - - B - - S SPACE 28 29 SPACE S - - 1.68 C - - S SPACE 30 297.66 AMP CALC. LOAD 40.73 19.73 122.58 1.68 57.57 3.60 PHASE LOAD PHASE A= 3.12 KVA PHASE B= 1.68 KVA PHASE C= KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 4.80 4.80 KVA 13.32 AMP CALC. LOAD 4.80 4.80 KVA 13.32 AMP REQUIRED INTEGRAL SPD OPTIONS: NOTES: EXIST DIST DP LOCATION: SERVING: FED FROM: MECH/ELEC/BOILER E130 480/277 VOLT 800 AMP MAIN LUGS ONLY SCCR: EXISTING 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE MAIN SWITCHBOARD CKT LOAD DESCRIPTION TYPE KVA A/P PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 PANEL 'LE' P - - 86.622 - - 200/3 - - A 400/3 - 124.690 - - P - PANEL 'M1' SEC 1 & 2 2 3 B 4 5 C 6 7 PANEL'LF' P - - 36.155 - - 100/3 - - A 100/3 - - - - - S - - SPARE 8 9 B 10 11 C 12 13 SPACE S - - A - - S SPACE 14 15 SPACE S - - B - - S SPACE 16 17 SPACE S - - C - - S SPACE 18 19 SPACE S - - A - - S SPACE 20 PHASE LOAD PHASE A= 114.65 KVA PHASE B= 113.22 KVA PHASE C= 108.13 KVA LOAD TYPE L R M H WH D A. K LM TOTAL LOADS PANEL DP KVA AMP PNL'LE' (XFMR TE) 24.31 19.52 2.35 40.44 1.18 86.62 KVA 104.19 AMP PNL'LF (XFMR TF) 8.28 8.28 16.00 3.60 36.16 KVA 43.49 AMP PNL'M1' (XFMR TM) 1.66 120.23 1.68 1.13 53.52 124.69 KVA 149.98 AMP CONN. LOAD 32.59 29.46 122.58 1.68 57.57 3.60 53.52 247.47 KVA 297.66 AMP CALC. LOAD 40.73 19.73 122.58 1.68 57.57 3.60 13.38 259.26 KVA 311.85 AMP NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. 3 REVIEWED FOR COMPLIANCE WITH NFPA7O-NEC MAY 2 6 2017 City of Tukwila BUILDING DIVISION RECEIVED clrer OF TUKWILA APR 2 5 2017 CENTER rc)iluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com ft Z� Z 2O J 1- w < 0 W z • W WOC cco o D -Iw °° O w O) Q o.tt U O Z- M <C U N. 0 C U G J a0 o O O l-- cO O)O I O C.) iHs°) a e 11 CV OP d' F- H .0 REVISION DATE Design: . FLR Drawn: BT Checked: FLR Project No. Issuance PERMIT SET Date: 4/14/2017 Drawing Title PANEL SCHEDULES Drawing Number CE5.03 0 vi w - J 0 w U - J w Z I a) w U CV N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC EXIST PANEL LE LOCATION: SERVING: FED FROM: MECH/ELEC/BOILER E130 MECH/ELEC/BOILER E130 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE EXIST DISTRIBUTION PANELBOARD'DP' FROM: CKT LOAD DESCRIPTION TYPE KVA MP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 1.960 20/1 A 20/1 A 20/1 3.525 L LIGHTING 2 3 LIGHTING L 2.580 20/1 0.720 B SPARE 20/1 2.645 L LIGHTING 4 5 LIGHTING L 3.140 20/1 0.540 20/1 C 20/1 1.330 L LIGHTING 6 7 LIGHTING L 3.065 20/1 A 20/1 A 20/2 - 5.120 - L - LIGHTING PARKING LOT 8 9 LIGHTING L 0.945 20/1 0.900 B D 10 11 SPARE S - 20/1 10 11 C 20/1 - S SPARE 12 13 SURGE SUPPRESSOR D -- -- 0.000 30/3 - - A 13 COMPUTER - - S SPACE 14 15 20/1 B R - - S SPACE 16 17 20/1 D C - - S SPACE 18 19 SPARE S - 20/1 A C - - - S SPACE 20 21 SPARE S - 20/1 20/1 B 20/1 - - S SPACE . 22 23 SPARE S - 20/1 20/1 64 C - - S SPACE 24 25 TRANSFORMER 'TE' (PANEL 'PE' SEC 1 & 2) P -- -- 62.312 100/3 - - A P - - 14.980 - - 20/1 - S SPARE 26 27 25 B R 20/1 - S SPARE 28 29 0.720 R C 20/1 - S SPARE 30 20/1 SPARE B 71 20/1 0.720 R RECEPTACLE 28 29 COMPUTER PHASE LOAD PHASE A= 32.07 KVA PHASE B= 29.81 KVA PHASE C= 24.75 KVA 1.600 D COMPUTER LOAD TYPE L R M H WH A D A 1< LM TOTAL LOADS PANEL LE 24.31 33 COMPUTER D 1.600 20/1 0.00 B 78 20/1 24.31 KVA 29.24 AMP PNL'PE' SEC 1 & 2 34 19.52 2.35 D 1.600 20/1 40.44 S C 1.18 62.31 KVA 74.95 AMP CONN. LOAD 24.31 19.52 2.35 D 1.600 20/1 40.44 S - 1.18 86.62 KVA 104.19 AMP CALC. LOAD 30.39 14.76 2.35 D 0.800 20/1 40.44 B R 0.29 88.23 KVA 106.13 AMP RECEPTACLE MEZZANINE NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. 41 COMPUTER D 0.800 EXIST PANEL PE SEC 1 LOCATION: FED SERVING: MECH/ELEC/BOILER E130 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE FROM: PANEL 'LE' FROM: PANEL 'LE' LOAD DESCRIPTION CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 COPIER D 1.000 20/1 A 20/1 - 20/1 0.720 R RECEPTACLE 2 3 RECEPTACLE R 0.720 20/1 SPARE B 1.176 20/1 0.720 R RECEPTACLE 4 5 RECEPTACLE R 0.540 20/1 C 20/1 C 20/1 0.720 R RECEPTACLE 6 7 RECEPTACLE R 0.900 20/1 A 20/1 0.360 20/1 0.800 D COMPUTER 8 9 RECEPTACLE R 0.900 20/1 D B 0.360 20/1 0.800 D COMPUTER 10 11 COMPUTER D 1.600 20/1 C - C 20/1 0.900 R RECEPTACLE 12 13 COMPUTER D 1.200 20/1 A - - 20/1 0.720 R RECEPTACLE 14 15 COMPUTER D 1.200 20/1 D B - 20/1 0.800 D COMPUTER 16 17 RECEPTACLE R 0.720 20/1 C - C 20/1 0.800 D COMPUTER 18 19 RECEPTACLE R 0.720 20/1 A 20/1 - 20/1 1.600 D COMPUTER 20 21 COMPUTER D 1.600 20/1 64 B 20/1 20/1 0.900 R RECEPTACLE 22 23 RECEPTACLE R 0.720 20/1 P - - 14.980 - - C 20/1 0.900 R RECEPTACLE 24 25 RECEPTACLE R 0.720 20/1 A 20/1 - 20/1 0.720 R RECEPTACLE 26 27 COMPUTER D 1.200 20/1 SPARE B 71 20/1 0.720 R RECEPTACLE 28 29 COMPUTER D 1.200 20/1 S SPACE C 20/1 1.600 D COMPUTER 30 31 RECEPTACLE R 0.900 20/1 A SPACE 76 20/1 0.800 D COMPUTER 32 33 COMPUTER D 1.600 20/1 S B 78 20/1 0.900 R RECEPTACLE 34 35 COMPUTER D 1.600 20/1 SPACE S C 20/1 0.900 R RECEPTACLE 36 37 COMPUTER D 1.600 20/1 A S - 20/1 0.360 R RECEPTACLE 38 39 COMPUTER D 0.800 20/1 85.19 AMP B R 20/1 0.360 R RECEPTACLE MEZZANINE 40 41 COMPUTER D 0.800 20/1 KVA PHASE B= 7.86 C 20/1 - S SPARE 42 LOAD TYPE L R M H WH 1.66 D A K LM PHASE LOAD PHASE A= 12.76 KVA PHASE B= 13.22 KVA PHASE C= 13.00 KVA 3.84 49.40 LOAD TYPE L R M H WH 0.98 D A K LM TOTAL LOADS CONN. LOAD 16.38 14.98 KVA 41.58 AMP CONN. LOAD 27.88 KVA 22.60 2.35 74.04 AMP 38.98 KVA 108.20 AMP CALC. LOAD 13.19 23.33 KVA 64.76 AMP CALC. LOAD 22.60 2.35 35.79 KVA 99.34 AMP REQUIRED FEED-THRU LUGS 23.63 KVA 65.58 AMP OPTIONS: NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. CIRCUITS 51 & 62-72 RELOCATED TO NEW PANEL PX2. NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. EXIST PANEL PE SEC 2 LOCATION: FED MECH/ELEC/BOILER E130 208/120 VOLT 250 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: FROM: PANEL 'LE' SERVING: CKT LOAD DESCRIPTION TYPE KVA NP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 43 RECEPTACLE D 0.720 20/1 A 1.600 20/1 20/1 - S SPARE 44 45 RECEPTACLE R 0.720 20/1 - B SPARE 20/1 1.176 M MOTORIZED SHADE 46 47 RECEPTACLE R 0.720 20/1 7 COMPUTER C 20/1 1.176 M MOTORIZED SHADE 48 49 RECEPTACLE R 0.720 20/1 A COMPUTER D 20/1 0.360 D FLOOR BOX LIBRARY 50 51 SPARE S - 20/1 11 B D 20/1 0.360 D FLOOR BOX LIBRARY 52 53 COMPUTER D 0.800 20/1 13 COMPUTER C - - S SPACE 54 55 COMPUTER D 0.800 20/1 A COMPUTER D - - S SPACE 56 57 COMP E -MO D 0.800 20/1 17 B D - - S SPACE 58 59 SPARE S - 20/1 19 SPARE C - - S SPACE 60 61 SURGE SUPPRESSOR D - - 0.000 - - 30/3 - - A SPARE S 20/1 - S SPARE 62 20/1 B S 20/1 - S SPARE 64 63 20/1 - C 20/1 - S SPARE 66 65 67 PANEL 'C1' P - - 14.980 - - 70/3 - - A 30 31 20/1 - S SPARE 68 27 B S 20/1 - S SPARE 70 69 29 SPARE C 20/1 - S SPARE 72 71 73 SPACE S - 20/1 A - 20/3 - - - - S SPACE 74 75 SPACE S - 20/1 4.80 B 4.58 - - S SPACE 76 77 SPARE S - - - 60/2 - - D C -- LM S SPACE 78 A 82 PHASE LOAD PHASE A= -- KVA PHASE B= S SPACE 80 79 81 SPACE S - - R B H - - S SPACE 82 83 SPACE S - - 70.83 KVA PHASE B= C - - S SPACE 84 70.83 KVA 85.19 AMP CALC. LOAD R M 70.83 WH D A K PHASE LOAD PHASE A= 8.20 KVA PHASE B= 7.86 KVA PHASE C= 7.28 KVA KVA PHASE C= OPTIONS: KVA LOAD TYPE L R M H WH 1.66 D A K LM TOTAL LOADS PANEL PE SEC 2 LM 2.16 2.35 9.47 AMP CONN. LOAD 3.84 49.40 1.18 8.35 KVA 23.18 AMP PANEL 'C1' 27.88 KVA 0.98 53.87 KVA 64.79 AMP CALC. LOAD 14.00 49.40 1.68 14.98 KVA 41.58 AMP CONN. LOAD 27.88 KVA 3.14 2.35 74.04 AMP NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -E01 LOCATION IN PANEL. 17.84 1.18 23.33 KVA 64.76 AMP CALC. LOAD 3.14 2.35 17.84 0.29 23.63 KVA 65.58 AMP NOTES: BOLD TEXT INDICATES REVISIONS TO EXISTING PANEL. CIRCUITS 51 & 62-72 RELOCATED TO NEW PANEL PX2. EXIST PANEL Cl LOCATION: SERVING: FED FROM: COMPUTER LAB E136 208/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 10,000 A' 3 PHASE AFC:. 4 WIRE MOUNTING: FLUSH SERVING: PANEL 'PE SEC 2' SERVING: CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 SURGE SUPPRESSOR D - - 0.000 - - 30/3 - - A 1.600 20/1 20/1 0.800 R COMPUTER 2 3 FIT-E06W, E07W, E08W B 1.065 20/1 - S SPARE 4 5 FIT-E03W, E04W, E05W M C- 20/1 0.400 D COMPUTER 6 7 COMPUTER D 1.600 20/1 A SPACE S 20/1 0.800 D COMPUTER 8 9 COMPUTER D 1.600 20/1 - B 8 20/1 0.800 D COMPUTER 10 11 COMPUTER D 1.600 20/1 13 FIT -E01 S, E02S, E03S C 20/1 0.800 D COMPUTER 12 13 COMPUTER D 1.600 20/1 A FC -E01 THRU E05 M 20/1 0.800 D COMPUTER 14 15 COMPUTER D 1.600 20/1 20/1 B S 20/1 0.800 D COMPUTER 16 17 COMPUTER D 1.600 20/1 20/3 - - 6.045 - - C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 23 SPACE 20/1 - S SPACE 20 21 SPARE S - 20/1 - B A 20/1 - S SPACE 22 23 SPARE S - 20/1 - - C 20/1 0.180 R RECEPTACLE ROOF 24 25 SPARE S - 20/1 A 30 31 20/2 - - - S - SPARE 26 27 SPARE S - 20/1 CU -E02 B 33 28 29 SPARE S - 20/1 B C C - - S SPACE 30 A - - 20/3 - - 3.795 - - M - - R/E-E01 38 39 SPACE S PHASE LOAD PHASE A= 5.60 KVA PHASE B= 4.80 KVA PHASE C= 4.58 KVA SPACE S - LOAD TYPE L R M H WH - D A K LM TOTAL LOADS CONN. LOAD S 0.98 82 PHASE LOAD PHASE A= 23.73 KVA PHASE B= 14.00 KVA PHASE C= 23.07 KVA 14.98 KVA 41.58 AMP CALC. LOAD LOAD TYPE 0.98 R M H WH 14.00 D A K 14.98 KVA 41.58 AMP CONN. LOAD NOTES: BOLD TEXT INDICATES CHANGES TO EXISTING PANEL. CIRCUIT 26 & 28 RELOCATED TO NEW PANEL PX2. PHASE LOAD PHASE A= 70.83 KVA PHASE B= 17.63 EXIST PANEL M1 SEC 1 LOCATION: SERVING: FED FROM: MECH/ELEC/BOILER E130 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 35,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: EXIST DISTRIBUTION PANELBOARD'DP' SERVING: CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 FIT -E01 N, E02N, E03N M 1.055 20/1 A 1.600 20/1 40/3 - - 22.770 - - M - - CU -E03 2 3 FIT-E06W, E07W, E08W M 1.065 20/1 47 B 20/1 4 5 FIT-E03W, E04W, E05W M 0.945 20/1 - A C 6 7 FIT-E01W, E02W M 0.665 20/1 A SPACE S 20/3 - - 3.795 - - M - - R/E-E03 8 9 FIT-E09W M 0.400 20/1 - B 8 10 11 FIT-E04S, E05S, E06S M 1.055 20/1 - A C 12 13 FIT -E01 S, E02S, E03S M 0.945 20/1 A SPACE S 30/3 - - 8.760 - - M - - AHU-E03 14 15 FC -E01 THRU E05 M 1.500 20/1 59 B S 16 17 SPARE S - 20/1 - S C 18 19 SPACE S - - A 20/1 1.125 20/3 - - 6.045 - - M - - R/E-E02 20 21 SPACE S - - - B SPACE 22 23 SPACE S - - - S C 24 25 SPACE S - - A 21 SPARE 30/3 - - 11.160 - - M - - AHU-E02 26 27 SPACE S - - - B SPARE 28 29 SPACE S - - - S C 30 31 PMP -E03 M - - 3.795 - - 30/3 - - A A - 60/3 - - 3.075 - - M - - CU -E02 32 33 SPACE B - 34 35 B B C 36 37 SPACE S - - A - - 20/3 - - 3.795 - - M - - R/E-E01 38 39 SPACE S - - S B - 40 41 SPACE S - - SPACE 80 C 42 S - - KVA B 20/1 - - S SPACE 82 PHASE LOAD PHASE A= 23.73 KVA PHASE B= 24.03 KVA PHASE C= 23.07 KVA C - - LOAD TYPE L R M H WH 27.88 KVA D A K LM TOTAL LOADS CONN. LOAD 1.66 PHASE LOAD PHASE A= 70.83 KVA PHASE B= 17.63 KVA PHASE C= 19.17 KVA 0.17 22.77 70.83 KVA 85.19 AMP CALC. LOAD R M 70.83 WH D A K LM 5.69 76.52 KVA 92.04 AMP REQUIRED 45.99 FEED-THRU LUGS 8.88 KVA PHASE C= OPTIONS: KVA NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -E02 & CU -E03 LOCATIONS IN PANEL. 45.99 KVA 55.32 AMP PANEL'MP1' R EXIST PANEL M1 SEC 2 . LOCATION: FED MECH/ELEC/BOILER E130 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 35,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE SERVING: FROM: EXIST DISTRIBUTION PANELBOARD'DP' SERVING: CKT LOAD DESCRIPTION TYPE KVA AIP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 43 SPARE S -- -- - 20/3 - - A 1.600 20/1 30/3 - - 8.760 - - M - - AHU-E01 44 45 EF -E04 B 0.680 46 47 B 20/1 C 48 49 SPACE S - - A 0.680 20/1 60/3 - - 30.750 - - M - - CU -E01 50 51 SPACE S - - M B 20/1 52 53 SPACE S - - SPARE 8 C 54 55 SPACE S - - A 20/1 0.300 - - S SPACE 56 57 SPACE S - - C B - - - S SPACE 58 59 SPACE S - - S 20/1 C - - S SPACE 60 61 PUMP CONTROL PANEL - M -- - 6.480 - 30/3 - - A 20/1 1.125 - - S SPACE 62 63 - B 19 - - S SPACE 64 65 18 19 C - - S SPACE 66 67 TRANSFORMER 'TM (PANEL'MP1') P - - 7.875 - - 30/3 - - A 21 SPARE 20/1 - S SPARE 68 69 - B S 20/1 - S SPARE 70 71 20/1 - C 20/1 - S SPARE 72 73 SPACE S - - A A - 20/1 - S SPARE 74 75 SPACE S - - - B B 20/1 - S SPARE 76 77 SPACE S - - - GIRLS HAND DRYER C 20/1 - S SPARE 78 79 SPACE S - - A LOAD TYPE L - - S SPACE 80 81 SPACE S - - KVA B 20/1 - - S SPACE 82 83 SPACE S - - K LM C - - S SPACE 84 1.68 39 1.13 27.88 KVA 33.53 AMP 0.68 7.88 KVA 21.86 AMP CALC. LOAD - 1.66 PHASE LOAD PHASE A= 17.07 KVA PHASE B= 17.63 KVA PHASE C= 19.17 KVA 0.17 8.05 KVA 22.33 AMP LOAD TYPE L R M H WH D A K LM TOTAL LOADS PANEL M1 SEC 2 PHASE LOAD PHASE A= e 45.99 COMPS IANC[ NFPA7O-i 8.88 KVA PHASE C= 8.96 KVA 30.75 45.99 KVA 55.32 AMP PANEL'MP1' R 1.66 3.41 WH 1.68 D 1.13 K LM 0.68 7.88 KVA 9.47 AMP CONN. LOAD 1.66 49.40 1.68 3.60 1.13 27.88 KVA 30.75 53.87 KVA 64.79 AMP CALC. LOAD 1.66 49.40 1.68 3.60 1.13 27.88 KVA 7.69 61.55 KVA 74.04 AMP NOTES: NO CHANGES TO THIS EXISTING PANEL. PANEL SHOWN TO INDICATE CU -E01 LOCATION IN PANEL. CIRCUIT 28 RELOCATED TO NEW PANEL PX3. • EXIST PANEL MP1 LOCATION: SERVING: FED FROM: MECH/ELEC/BOILER E130 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 60 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE s7 �.i16ne.i'i 1 W� �. i PANEL 'Ml' SEC 2 SERVING: CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 EF -E01 M 0.680 20/1 A 1.600 20/1 20/1 0.200 M PMP -E05 2 3 EF -E04 M 0.680 20/1 D B 20/1 20/1 - S SPARE 4 5 EF -E02 M 0.680 20/1 R 0.720 C 20/1 1.680 WH WH -E01 6 7 EF -E03 M 0.680 20/1 A 0.720 20/1 20/1 - S SPARE 8 9 EF -E05 M 0.190 20/1 - B SPACE 20/1 0.300 M EF -E06 10 11 RECEPTACLE UNDER PANEL R 0.180 20/1 13 SPARE C 20/1 - S SPARE 12 13 RECEPTACLE UNDER PANEL R 0.180 20/1 A SPARE S 20/1 - S SPARE 14 15 SPARE S - 20/1 17 B S 20/1 1.125 D COMP -E01 16 17 SPARE S - 20/1 19 TRANSFORMER 'TF' (PANEL 'PF') C 20/1 1.300 R WH -E02 18 19 SPACE S - - A 0.360 B - - S SPACE 20 21 SPARE S - 20/1 20/1 B S - - S SPACE 22 23 SPARE S - 20/1 - - C - - S SPACE 24 25 SPARE S - 20/1 A - S - 28 S SPACE 26 27 SPACE S - - - B S - - S SPACE 28 29 SPACE S - - GIRLS HAND DRYER A C -. - S SPACE 30 12.11 KVA SPACE 32 33 HANDICAP HAND DRYER LOAD TYPE L R M H WH PHASE LOAD PHASE A= 1.74 KVA PHASE B= 2.30 KVA PHASE C= 3.84 KVA 8.28 20/1 LOAD TYPE L R M H WH 37 D. A K LM TOTAL LOADS CONN. LOAD 1.66 3.41 16.00 1.68 39 1.13 27.88 KVA 33.53 AMP 0.68 7.88 KVA 21.86 AMP CALC. LOAD - 1.66 3.41 16.00 1.68 SPACE 1.13 36.16 KVA 43.49 AMP 0.17 8.05 KVA 22.33 AMP - NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL. S SPACE 42 16.00 3.60 EXIST PANEL LF LOCATION: SERVING: FED FROM: OFFICE E104 480/277 VOLT 125 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 4 WIRE MOUNTING: FLUSH s7 �.i16ne.i'i 1 W� �. i EXIST DISTRIBUTION PANELBOARD'DP' SERVING: CKT LOAD DESCRIPTION TYPE KVA AIP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 2.510 20/1 A 1.600 20/1 20/1 0.360 L LIGHTING 2 3 LIGHTING L 2.255 20/1 D B 20/1 20/1 - S SPARE 4 5 LIGHTING L 3.150 20/1 R 0.720 C 20/1 - S SPARE 6 7 SURGE SUPPRESSOR D - - 0.000 - - 30/3 -. - A 0.720 20/1 - - S SPACE 8 9 COMPUTER B 9 - - S SPACE 10 11 20/1 C - - S SPACE 12 13 SPARE S - 20/1 A 20/1 1.200 - - S SPACE 14 15 SPARE S - 20/1 B 1.200 - - S SPACE 16 17 SPARE S - 20/1 20/1 C - - S SPACE 18 19 TRANSFORMER 'TF' (PANEL 'PF') P - - 27.880 - - 50/3 - - A 20/1 0.720 20/1 - S SPACE 20 21 0.360 B A 20/1 - S SPACE 22 23 20 21 C 20/1 - S SPACE 24 25 SPACE S - - A 23 - - S SPACE 26 27 SPACE S - - 20/1 B D - - S SPACE 28 29 SPACE S - - - S C - - S SPACE 30 C. 20/1 - S SPARE r1: OF -INK 31 GIRLS HAND DRYER A 1.200 PHASE LOAD PHASE A= 12.91 KVA PHASE B= 11.14 KVA PHASE C= 12.11 KVA SPACE 32 33 HANDICAP HAND DRYER LOAD TYPE L R M H WH - D A K LM TOTAL LOADS PANEL LF 8.28 20/1 C - 0.00 S SPACE 37 8.28 KVA 9.95 AMP XFMR 'TF' - 8.28 20/1 - 16.00 3.60 39 SPACE 27.88 KVA 33.53 AMP CONN. LOAD 8.28 8.28 - - S 16.00 3.60 SPACE S 36.16 KVA 43.49 AMP CALC. LOAD 10.34 8.28 - - S SPACE 42 16.00 3.60 38.22 KVA 45.98 AMP NOTES: PANEL SHOWN FOR REFERENCE ONLY, NO CHANGES TO THIS EXISTING PANEL.REVIEWED PHASE LOAD PHASE A= e 10.04 COMPS IANC[ NFPA7O-i 8.88 FOR WITH EC MAY 2 6 2017 City of Tukwila ISION EXIST PANEL PF LOCATION: FED OFFICE E104 208/120 VOLT 125 AMP MAIN LUGS . 3 PHASE 4 WIRE s7 �.i16ne.i'i 1 W� �. i ONLY CCR: 1O 000'A �'- AFC: MOUNTING: FLUSH SERVING: FROM: PANEL 'LF' CKT LOAD DESCRIPTION TYPE KVA AIP PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 COMPUTER D 1.600 20/1 A 20/1 0.720 R RECEPTACLE 2 3 COMPUTER D 1.600 20/1 B 20/1 0.720 R RECEPTACLE 4 5 RECEPTACLE R 0.720 20/1 C 20/1 1.600 D COMPUTER 6 7 RECEPTACLE R 0.720 20/1 A .20/1 1.600 D COMPUTER 8 9 COMPUTER D 1.600 20/1 B 20/1 0.720 R RECEPTACLE . 10 11 COMPUTER D 1.600 20/1 C 20/1 1.200 D COMPUTER 12 13 RECEPTACLE R 0.720 20/1 A 20/1 1.200 D COMPUTER 14 15 RECEPTACLE R 0.720 20/1 B 20/1 1.600 D COMPUTER 16 17 RECEPTACLE R 0.720 20/1 C 20/1 0.720 R RECEPTACLE 18 19 RECEPTACLE CLOSET E104A R 0.360 20/1 A 20/1 0.720 R RECEPTACLE 20 21 SURGE SUPPRESSOR D - - 0.000 - - 30/3 - - B 20/1 0.720 R RECEPTACLE 22 23 C 20/1 1.200 D COMPUTER 24 25 A 20/1 1.200 D COMPUTER 26 27 SPARE S - 20/1 B 20/1 - S SPARE PT,CEl\P 29 SPARE S - 20/1 C. 20/1 - S SPARE r1: OF -INK 31 GIRLS HAND DRYER A 1.200 20/1 A - - S SPACE 32 33 HANDICAP HAND DRYER A 1.200 20/1 B - - S SPACE API( 254 35 BOYS HAND DRYER A 1.200 20/1 C - - S SPACE 37 SPACE S - - A 20/1 - S SPARE r)21\lii +- ci\ 39 SPACE S - - B - - S SPACE 40 41 SPACE S - - C - - S SPACE 42 PHASE LOAD PHASE A= e 10.04 KVA PHASE B= 8.88 KVA PHASE C= 8.96 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 8.28 16.00 3.60 27.88 KVA 77.39 AMP CALC. LOAD 8.28 16.00 3.60 27.88 KVA 77.39 AMP NOTES: BOLD TEXT INDICATES CHANGES TO EXISTING PANEL. CIRCUIT 40 TO BECOME GENERAL PURPOSE RECEPTACLE. CIRCUIT 28 RELOCATED TO NEW PANEL PX3. • 1Ln7�3 0 117 TER rllua architects arch tecture planning inter or design. 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com N- Z� W Z 2 Q.. 12- < <C so Z W LtJ Ct CO CO L J W Q o<. �U O Z <C U U to r 1u 0 2' J o O0 O o CO�N o I- CO a) O ca d' rY de w/��� g 1COO121--LU W O 1- d- 1- - r 11 REVISION DATE Design: FLR Drawn: BT Checked: FLR Project No. Issuance PERMIT SET Date: 4/14/2017 Drawing Title PANEL SCHEDULES Drawing Number CE5.04 CE5.04_PANEL SCHEDULES.DWG 0.1 tV N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INCA I 1 El NI22ElEl121 122621116622 121111 122221211211 01El 111210212122 El111j MI ® MEM= Ell- 12212241=1 El- I 7E2E60 GATE G-3 ESL CLASS VOLUNTEER RM. LA101 -9 L=J I LA/5 -- 12E1520E2 E111212221111 El 121 122222126E1 - ■' ELEC. CL'.T. A116 1 i SI 11122122122 11/ El =MEM 121 112E=2221 -- 75 El El MINI211112 ill 12212622111 El 12 11$212151111111 El 12=2M11 12 EWE= Ell IS nossossmati 1111 El MEM= 111 El TEEM= ill 121 11022110111 121 E6221E012 1111 161 MIME= II OS 2212221212 terZA_ GATE G-2 r� l LB/9 GENEFRAL NOTES 1. ALL LIGHT FIXTURES SHOWN DASHED ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 0111211211011 - . 122212261111 - 111 1110112121161 - -12602122111 - - 2211101211121 - - 16121111221111 - - 112112221211- - 121201211111 111 1221E0Eill - - 16211111152111 - 111212E222221 n -11211611122211. - 211211102112111 - - 6121221012011 . -1212E12211E1. . 1121112121101 BA IMIEWEINO 101.M.21. re EL 5 P ' r II I II II II 0 L = J KITCHEN N 0 L====J FOOD STORAGE N II N II 0 II II L = J JANITOR CLST. A117 II II I- --II S� ONDARY DAYLIGHT E, 53 SQ.FT PRIMARY DAYLIGHT ZONE, 68 SQ.FT I N IN I II A WOMEN'S A103 .11 r====1 N II L r -= II II L .I• 10if L====J r-=--1 u II L====J r-___, N II L L P.E. GYMNASIUM STAFF WORKROOM A105 r 11 u 11 L= ==J r-===1 N II MULTI-PURPOSE/ CAFETERIA • r====1 II N 15 i 0 II L====J GIRLS l 1 OFFICE A108 N II 4111 STORAGE TOILET A111 • r====1 N II L 15 ELI HEALTH RM.11 = a A110 VESTIBULE N II L====J LA 21 •' FED:`' AIN ENTRY ,�,C 1�.r -1\`r 1\_ r -\\ SECURED —VESTIBULE .UPPo _ p BUILDING B PRINCIPAL OFFI OFFICE BUILDING A BUILDING A & B - FLOOR PLAN - LIGHTING PLAN SCALE : 1/8" =11-0" 0 0 10 11 12 FLAN NOTES NOT USED. PROVIDE NEW LED EXIT SIGN WITH BATTERY PACK. PROVIDE UNSWITCHED HOT TO EXIT SIGN. NOT USED. PROVIDE NEW 1x4 LED PENDANT MOUNT FIXTURES. MOUNT AT +9'-6" AFF TO BOTTOM OF FIXTURE, TYPICAL. PROVIDE NEW LED DOWN LIGHT FIXTURE. EXISTING FIXTURE RELOCATED TO THIS LOCATION. SEE SHEET CED1.01 FOR CURRENT LOCATION. MAINTAIN EXISTING SWITCHING CONFIGURATION. REMOVE THE INTERIOR PORTION OF THE EXISTING ROUND RECESSED FIXTURE AND PROVIDE A NEW SURFACE MOUNT FIXTURE OVER EXISTING FIXTURE LOCATION. PROVIDE ALL WIRING AND CONNECTIONS FOR COMPLETE OPERATION. NEW FIXTURES SHALL BE CONTROLLED VIA EXISTING BUILDING MANAGEMENT SYSTEM CONTROLS. PROVIDE NEW 2x4 LED FIXTURES. NOT USED. NOT USED. EXISTING SWITCHES FOR A113 TO REMAIN. LIGHTING ROOM CONTROLLER LOCATED IN ACCESSIBLE CEILING SPACE. PROVIDE ONE CONTROLLER FOR EACH SEPARATELY SWITCHED ZONE IN THIS ROOM. CONTROLLERS SHALL BE CONNECTED TO THE LV SWITCHES, OCCUPANCY SENSOR, PHOTO CELL AND RECEPTACLE CONTROLLER IN THIS ROOM. SEE OFFICE LIGHTING/RECEPTACL CONTROL DIAGRAM ON SHEET CE8.03. 13 OCCUPANCY SENSOR TO CONTROL THE TWO DOWNLIGHTS IN THIS VESTIBULE. CONTROL SHALL BE AUTOMATIC ON AND AUTOMATIC OFF. PROVIDE POWER PACKS AS REQUIRED. 14 SEE SHEET CE8.03 FOR ROOM B113 LIGHTING CONTROL DIAGRAM. 15 NUMBER NEXT TO PHOTOCELL INDICATES FIXTURES CONTROLLED IN TOPLIGHT ZONE. 1117ftmo*0309) REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC MAY 2 6 2017 City of.Tuk ila BUILDING DIVISION RECEIVED •%rcY OF TUKWILA KEY PLAN rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 14.114 V TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com C z(/) LLI Z 2O J I— LLI Q 0 LLI Z W W Owrn U O o� z - V /1 �= N i r M _ OO) V P W z 0 U 1- co J OD O O pui l- o rn o � o .0 5CD ��03 T Y M��wi I- I- I- .c REVISION DATE Design: Drawn: Checked: Project No. FLR DPH, BT FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title FLOOR PLAN - BUILDING A & B LIGHTING PLAN Drawing Number CE7.O1 BLDG-A_B LTG.DWG N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC RECONNECT EXISTING TWO (2) TELEPHONE LINES (E)POST INDICATOR VALVE & VAULT TAMPER SWITCHES LJ (E)BACKFLOW TAMPER SWITCHES .®- rM-' LJ (E)WET FIRE SPRINKLER RISER TAMPER SWITCHES (E)WET FIRE SPRINKLER RISER FLOW SWITCHES .®--- ► MJ (E)WET FIRE SPRINKLER RISER TAMPER SWITCHES ---MS (E)WET FIRE SPRINKLER RISER FLOW SWITCHES (E)DRY FIRE SPRINKLER RISER TAMPER SWITCH (E)DRY FIRE SPRINKLER RISER HI -LOW AIR SWITCH (E)DRY FIRE SPRINKLER RISER FLOW SWITCHES • (E)DRY FIRE SPRINKLER RISER TAMPER SWITCH (E)DRY FIRE SPRINKLER RISER HI -LOW AIR SWITCH (E)DRY FIRE SPRINKLER RISER FLOW SWITCHES .®---LMJ (E)EMCS CONTROL EXISTING PRINTER i E L_1 -J DED. CKT_-rTL� CONTROL RELAY LMJ LDJ LDJ (E)DOOR HOLDER CIRCUIT PROVIDE AND CONNECT CONTROL -44 TO 120VAC POWER RELAY r LLRJ ui - �t---2 ---- �F� (E)FIRE ALARM AUDIO/VISUAL ALARM ��EXISTING FIRE ALARM SLC LOOP DEVICES AND -DETECTORS (E)FIRE/SMOKE DAMPER CIRCUIT RETURN , t, D` ,D /1\ PROVIDE REMOTE INDICATING LIGHT TO SIGNAL SMOKE DUCT DETECTOR ACTIVATION. MOUNT IN CEILING BELOW UNIT. PROVIDE CONNECTION TO DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS OF 2000 CFM AND OVER SEE MECH DRAWING EQUIP. SCHEDULES. (E)NELHVAC .DDC CONTROL HVAC i PA L J FOR HVAC SHUT DOWN NEW FIRE ALARM SLC LOOP DEVICES AND DETECTORS r > 1/1 DEDICATED 120V CIRCUITS, SEPARATE HOME RUN AND INSULATED GROUND. NEW EST I0500 F.A. PANEL NEW FA—NAC PANEL CIRCUIT TYPICAL 8 EXISTING 1 1 EXISTING 1 1 EXISTING FA -NAC i - i FA -NAC i - i FA -NAC L PANEL J L PANEL J L PANEL J MAP� LFA A] NEW AUDIO/VISUAL ALARM CIRCUIT TYPICAL (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL NEW FA -NAC PANEL (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL \u rni----fit---lI- NEW AUDIO/VISUAL ALARM CIRCUIT TYPICAL (E)FIRE ALARM REMOTE GRAPHIC LED ANNUNCIATOR MAP (E)FIRE ALARM REMOTE LCD ANNUNCIATOR BATTERY CABINET GROUNDING REMOVE EXISTING FIRE ALARM I DIALER. FIRE ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE FIRE ALARM NOTES: 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING & CONNECTIONS TO ALL DEVICES FOR COMPLETE FIRE ALARM SYSTEM. 2. ALL DEVICES WILL BE MOUNTED IN ` AN ACCESSIBLE SPACE AND AT THE ELEVATION PER NFPA 72, ADA, AND AHJ CODES. 3. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACE. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT PER MANUFACTURERS RECOMMENDATION. 5. SEE FIRE ALARM SPECIFICATION FOR COMPLETE DETAILS. 6. PROVIDE NEW FIRE ALARM PANEL ADDRESSABLE. 7. PROVIDE SHUT DOWN CONNECTIONS FOR ALL 2000CFM HVAC UNITS WITH DUCT DETECTORS AS SHOWN. 8. SET ALL VISUAL DEVICES TO PROVIDE THE RIGHT COVERAGE OF CANDELA FOR THE SPACE PER NFPA 72 AND AHJ CODES. 9. SET ALL AUDIO DEVICES TO TEMPORAL AND TO BE 15dB ABOVE AMBIENT SOUND LEVEL OF THE ROOM PER NFPA 72 CODES TABLE. 10. ALL AUDIO AND VISUAL DEVICE WILL BE SYNC PER NFPA 72 CODES. 11. PROVIDE COMPLETE REPROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER MONITORING BY POINTS. 12. PROVIDE COMPLETE SHOP PLANS FOR INSTALLATION AND AS -BUILT SET OF THESE PLANS NEXT TO FIRE ALARM PANEL ON COMPLETION. 13. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. 14. PROVIDE FIRE ALARM NETWORK MODULES BETWEEN BUILDINGS TO USE ONE DIALER FOR MONITORING. 15. THE EXISTING EST QUICK START FIRE ALARM PANEL IS OBSOLETE AND IS NOT SUPPORTED BY MANUFACTURER. 16. REPLACE EXISTING BOSCH FIRE/SECURITY PANEL/DIALER & EST QUICK START WITH NEW EST I0-500 FIRE ALARM PANEL. ALL EXISTING FIRE ALARM DEVICES TO REMAIN. PROVIDE PROGRAMMING AND A COMPLETE FIRE ALARM SYSTEM TEST TO GENERATE AN EVENT LOG REPORT WITH CENTRAL STATION MONITORING OF ALL FIRE ALARM ADDRESSABLE POINTS ALARM, SUPERVISORY, AND TROUBLES. 17. PROVIDE FOUR (4) SYNC MODULES TO MATCH EXISTING HORN/STROBE MANUFACTURER PROTOCOL. INSTALL EACH SYNC MODULE NEXT TO EXISTING NAC BOOSTER PANEL. PROVIDE TEN (10) HORN/STROBES TO REPLACE ANY EXISTING NON-MATCHING HORN/STROBES. PROGRAM SETTING OF THE SYNC MODULE TO MATCH MANUFACTURER HORN/STROBES. COMPLETE FINAL TESTING OF ALL HORN/STROBE CIRCUITS ON NORMAL POWER AND BACKUP BAI ILRY. ALL CIRCUIT SHALL BE TESTED AT THE END OF LINE RESISTOR (EOL) TO DOCUMENT THE VOLTAGE DROP. 18. CHANGE ALL HORN/STROBE AND STROBE SETTINGS TO 15CD IN ALL CORRIDORS AND SMALL RESTROOMS. 19. CHANGE ALL CLASSROOMS, ADMIN, AND LIBRARY HORN/STROBE SETTINGS TO 75DBA LEVEL. 20. PROVIDE TWO(2) HORN/STROBES TO CLASSROOM C107B AND THE EXTERIOR BREEZEWAY BETWEEN BUILDING D AND E. 21. PROVIDE ONE 1) STROBE CLASSROOM D111. 22. PROVIDE NEW NAC BOOSTER PANEL TO MATCH EXISTING HORN/STROBE MANUFACTURER PROTOCOL FOR ALL NEW HORN/STROBES IN NEW DEVICES. MOUNT ABOVE EXISTING NAC BOOSTER PANELS IN BUILDING D MAIN ELECTRICAL ROOM. 23. REPLACE ALL EXISTING FIRE ALARM PANELS BACKUP BATTERIES. 24. PROVIDE NAC BOOSTER PANEL TO MATCH EXISTING HORN/STROBE MANUFACTURER PROTOCOL FOR BUILDING D IDF ROOM ON THE WEST WALL TO REDUCE THE EXISTING LOAD ON BUILDING D AND E. INTERCEPT EXISTING HORN/STROBE CIRCUITS. TROUBLESHOOT WHICH HORN/STROBES NEED TO BE REDUCED IN A FIELD. 25. FIRE ALARM CONTRACTOR TO SUBMIT DRAWINGS FOR FIRE ALARM PERMIT BY TUKWILA BUILDING DEPARTMENT. 26. PROVIDE NEW AS -BUILT AUTOCAD DRAWINGS BY THE FIELD VERIFICATION OF ALL EXISTING FIRE ALARM SYSTEM. DOWNLOAD EXISTING PROGRAM DATA OF THE EXISTING FIRE ALARM SYSTEM. MATCH THE EXISTING DATA WITH NEW AS -BUILT DRAWING. PLOT OUT 11 BY 17 DRAWINGS TO BE PROVIDED FOR THE FINAL TEST OF THE EXISTING FIRE ALARM SYSTEM. 27. PROVIDE THE AHJ AT FINAL ACCEPTANCE THE FOLLOWING DOCUMENTS: a. AS -BUILT DRAWINGS SHALL BE FULL CONSTRUCTION SET WITH REDLINE MARKUPS THAT CONTAIN THE FOLLOWING (ALL ZONING, DEVICE POINT NUMBERS, NEW DEVICE CONDUIT OR WIRING PATHWAYS, AND EXACT LOCATION OF DEVICES AND PANELS.) b. EXISTING AS -BUILT DRAWINGS SHALL HAVE ALL FIRE ALARM PANELS AND DEVICES. c. HAFT SIZE GRAPHIC MAP OF EACH FLOOR WITH ZONES AND ADDRESSABLE POINT DEVICES. ( NO WIRE ) d. CENTRAL STATION MONITORING PRE-TEST REPORT OF ALL ADDRESSABLE POINTS. e. FIRE ALARM PANEL ALARM, SUPERVISORY, AND TROUBLE EVENT LOG REPORT OF ALL DEVICES. f. ADDRESSABLE POINTS LIST. g. WRITTEN DETAIL DESCRIPTION OF EACH DUCT DETECTOR LOCATION TO DIRECT A PERSON TO THAT LOCATION IN THE CLOSEOUT DOCUMENTS. PROVIDE PHENOLIC LABEL INDICATING FOR ALL DUCT DETECTORS. h. COMPLETED NFPA 72 RECORD OF COMPLETION AND INSPECTION CURRENT FORMS TO OWNER AND AHJ. i. PROVIDE THE DIGITAL COPY OF ALL ABOVE ON ONE FOLLOWING (CD-ROM, DVD, OR FINGER DRIVE). j. PROVIDE ALL THE ABOVE DOCUMENTS IN O&M MANUALS BINDER. k. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. Lfl' 03 REVIEWED .FOR COMPLIANCE WITH NFPA 70 NEC MAY 2 6 2017 City of Tukwila BUILDING DIVISION r: TUKWILA. ILA ';R. t 5 2017 • (..:ENTER • rafluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 1.14 V V— TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: Drawn: Checked: Project No. BCY BCY FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title SYSTEMS ONE -LINE AND DETAILS Drawing Number CE8.01 SYSTEMS ONE -LINE & DETAILS.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC 0 cd w 0 NOTES: 1. PROVIDE CARD READER TO MATCH EXISTING AS SHOWN ABOVE. REFER TO FLOOR PLANS FOR MULTIPLE AND SINGLE DOORS LOCATIONS. 2. PROVIDE WATER TIGHT CONDUIT, LB FITTING, CABLING, AND ACCESSORIES TO INSTALL ELECTRIC STRIKE AND CARD READER ON EXISTING GATE. USE EXISTING GATE DOOR FRAME CHANNELING TO GET DOWN TO CARD READER AND GATE DOOR CHANNELING TO GET DOWN TO ELECTRIC STRIKE. ACCESS CONTROL EXISTING GATE OUTSIDE SCALE: NONE 1"C. Inc. SECURITY CABLING 1/2"C SINGLE DOOR OR GATE FINISHED FLOOR DETAIL NOTES: 0 JUNCTION BOXES AS REQUIRED. OPROVIDE ROUGH -IN FOR DOOR CONTROL DEVICES, PASS-THROUGH HINGE, AND NEW STRIKE HARDWARE. CONCEAL ALL INSTALLATIONS. REFER TO FLOOR PLANS. 0 PROVIDE CONDUIT TO ELECTRIC LOCK AND STRIKE PLATE. COORDINATE WITH DOOR HARDWARE SUPPLIER FOR PROPER ROUGH -IN. NOTES: 1. PROVIDE DOOR CONTACTS AS SHOWN ON FLOOR PLANS FOR MULTIPLE AND SINGLE DOORS. 2. PROVIDE WATER TIGHT CONDUIT, LB FITTING, CABLING, AND ACCESSORIES TO INSTALL ELECTRIC STRIKE AND CARD READER ON EXISTING GATE. USE EXISTING GATE DOOR FRAME CHANNELING TO GET DOWN TO CARD READER AND GATE DOOR CHANNELING TO GET DOWN TO ELECTRIC STRIKE. REFER TO EXISTING PICTURES ABOVE. DOOR ACCESS CONTROL AND SECURITY DETAIL SCALE: NONE PROVIDE CONNECTION TO LOCAL AREA NETWORK 120VAC, 20A 120V, 20A CIRCUIT NOTES: NOTES: 1. PROVIDE CARD READER TO MATCH EXISTING AS SHOWN ABOVE. REFER TO FLOOR PLANS FOR MULTIPLE AND SINGLE DOORS LOCATIONS. 2. PROVIDE WATER TIGHT CONDUIT, LB FITTING, CABLING, AND ACCESSORIES TO INSTALL ELECTRIC STRIKE AND CARD READER ON EXISTING GATE. USE EXISTING GATE DOOR FRAME CHANNELING TO GET DOWN TO CARD READER AND GATE DOOR CHANNELING TO GET DOWN TO ELECTRIC STRIKE. ACCESS CONTROL EXISTING GATE INSIDE SCALE: NONE D EMERGENCY LOCK -DOWN PUSH BUTTON FOR PRINCIPAL OFFICE SAP FAP SECURITY ALARM CONNECTION FOR DISARMING. FIRE ALARM CONNECTION FOR UNLOCK. J -BOX ABOVE ACCESS CONTROL DOORS ACCESS CONTROL 4 -READER PANEL DOOR LOCK POWER SUPPLY BATTERY CABINET REMOTE RELAY MASTER DOOR INTERCOM STATION 120V, 20A o MI REMOTE RELAY ADMIN OFFICE MAIN DESK REMOTE DOOR INTERCOM STATION ELECTRIC DOOR LOCK REQUEST TO EXIT MOTION DETECTOR ( REX ) CARD READER TYPICAL DOOR COMPONENTS ALL WIRING TO BE HOMERUN TO THE SECURITY CONTROL PANEL SCHOOL MAIN ENTRY DOORS 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING AND CONNECTIONS TO ALL DEVICES FOR COMPLETE OPERATIONAL SYSTEM. 2. PROVIDE COMPLETE ACCESS CONTROL SYSTEMS PER ELECTRICAL PLANS, MECHANICAL PLANS, ARCHITECTURAL PLANS, SPECIFICATIONS AND CODE REQUIREMENTS. 3. PROVIDE REQUIRED 4 -READER CONTROL UNITS AND RELAYS TO OPERATE ALL AUXILIARY DEVICES. 4. DOOR CONTRACTOR TO PROVIDE, INSTALL, AND POWER ELECTRIC DOOR LOCKS. 5. PROVIDE J -BOX ABOVE THE DOOR TO CONNECT DOOR POSITION SWITCH WIRING. 6. PROVIDE J -BOX ABOVE THE DOOR TO CONNECT ELECTRIC DOOR LOCK WIRING. 7. CARD READER ZONE WILL INTERFACE ACCESS CONTROL SYSTEM WITH SECURITY PANEL TO DISARMING SECURITY ZONE. 8. PROVIDE CARD READER PEDESTAL(S) AS REQUIRED. 9. PROVIDE INTERFACES WITH SECURITY SYSTEM PER SECURITY PARTITION SCHEDULE. 10. PROVIDE INTERFACES WITH SECURITY SYSTEM FOR LOCK -DOWN OF THE SCHOOL. THIS WILL BE MONITORED BY CENTRAL STATION. 11. PROVIDE INTERFACE WITH MASTER DOOR INTERCOM STATION TO UNLOCK MAIN ENTRY GATE. ACCESS CONTROL SINGLE -LINE DIAGRAM SCALE: NONE NOTES: 1. REPAIR EXISTING GATE CONDUIT AND CABLING. REPLACE EXISTING EXTERIOR CONDUIT WITH WATER TIGHT CONDUIT, LB FITTING, AND ACCESSORIES. REUSE EXISTING ACCESS CONTROL CABLING. MATCH THE EXISTING ACCESS CONTROL GATE SHOWN ON THIS SHEET. REFER TO FLOOR PLANS TO LOCATE THIS EXISTING GATE BETWEEN GYM/CAFE BUILDING AND BUILDING D. ACCESS CONTROL EXISTING GATE REPAIR SCALE: NONE GYM/CAFE AREA 0 M F -IMI ---1 M I- i M H---� LTJ Ti LTJ LTJ LIJ LIJ DCI IDC /I\ /I\ L_J L -J (E)BLDG C - IMF -SMI --- (E)ADMIN AREA LTJ LTJ 1 r� r�-� L.J LIJ /I\ /I\ r-1 r- MF - M F1 LTJ LTJ LIJ LJi / I \ /I \ 3/4"C TO DDC - F 3/4"C TO LCP -■----- LL (E)KEYPAD ADMIN �KPF---- r� (E)KEYPAD GYM LKPF---- (E)KEYPAD BLDG C KFF--- I (E)TELEPHONE LINE (E)BLDG E r- r- -iMI--IM1-------®► LTJ LTJ. rH r'� LIJ LIJ / \ (E)BLDG D r---- IMF -IMF -----.10 LTJ LTJ r�r�� LJ LIJI / I \ / I \ L L 1 1 J EXISTING NAPCO SECURITY ALARM CONTROL PANEL L (E)INTERFACE WITH ACCESS CONTROL (E)KEYPAD BLDG D (E)KEYPAD BLDG E (E)120VAC, 20A DETAIL NOTES: OPROVIDE NEW MOTION SENSOR BOSCH TRI -TECH PART # ISC-BDL2-W12 BLUE LINE OR APPROVED EQUAL 10 -DAYS PRIOR TO BID. PROVIDE (2)4#18 CABLING FROM NEAREST EXISTING MOTION SENSOR. REFER TO FLOOR PLANS. NOTES: 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING AND ALL CONNECTIONS TO DEVICES FOR COMPLETE OPERATIONAL SYSTEM. 2. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACES. 3. PROVIDE REQUIRED CONTROL RELAYS TO OPERATE ALL AUXILIARY• DEVICES. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT. 5. PROVIDE COMPLETE INSTALLATIONS PER SYSTEM SHOP DRAWINGS. 6. PROVIDE COMPLETE EQUIPMENT, DEVICES AND CONNECTIONS TO UL LISTED MONITORING STATION PER OWNER'S DIRECTION. 7. REFER TO SECURITY ALARM SPECIFICATIONS FOR COMPLETE DETAILS. 8. PROVIDE COMPLETE PROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER. PROVIDE NEW DIALER IF REQUIRED. 9. PROVIDE J -BOX ABOVE DOOR TO CONNECTION SECURITY DOOR CONTACT SWITCH WIRING. 10. CARD READER ZONE WILL INTERFACE ACCESS CONTROL SYSTEM WITH SECURITY PANEL TO DISARMING SECURITY ZONE. 11. PROVIDE AND PROGRAM TWO CONTACTS THAT WILL ACTIVE ON ALARM OR TROUBLE OF THE SECURITY SYSTEM. THESE CONTRACTS WILL INTERFACE WITH THE BUILDING DDC CONTROL PANEL AND THE LIGHTING CONTROL PANEL (LCP) TO TURN INTERIOR AND EXTERIOR LIGHTING TO FULL ON. 12. PROVIDE POINT MODULES OR SOFTWARE PROGRAMMING TO INTERFACE ACCESS CONTROL SYSTEM TO MONITOR LOCKDOWN OF THE SCHOOL TO CENTRAL STATION. SECURITY ALARM SYSTEM SCHEMATIC DIAGRAM SCALE: NONE REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC MAY 26 2017 City of.TukwiIa BUILDING DIVISION • CITY APR 2 5 2017 ;. CENTER L-11 0 3 Q 8 rllua architects architecture planning inter or design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com >-/ z� W z 2O W <C O Z > W/ W Co • OW � uj U CI O VJ <C U Oto c:2 0 I 2 0 J CO O O O • I-- CCo o8 0) I O = coo D W O I- d- I- I- .c REVISION DATE Design: Drawn: Checked: Project No. BCY BCY FLR Issuance PERMIT SET Date: 4/14/2017 Drawing Title SYSTEMS ONE -LINE AND DETAILS Drawing Number CE8.02 CE8.02_SYSTEMS ONE -LINE & DETAILS.DWG 2 0 N ti 0 N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC STRUCTURAL CEILING SUSPENDED CEILING PROVIDE MINIMUM 3/4" CONDUIT IN ALL NON -ACCESSIBLE AREAS, EXPOSED OPEN AREAS AND ROOF TOPS rFININSHED FLOOR CLOCK/SPEAKER REQUIREMENTS SCALE: NONE PROVIDE A RAULAND SPEAKER, RAULAND 2420 DIGITAL CLOCK, FLUSH BACK BOX RE117S AND CLOCK SPEAKER GRILL. PROVIDE PLENUM CABLE WEST PENN ZH11018, 4 PAIR 1 PAIR SHIELDED CABLE. CONTACT BEN SWERK AT ELECTROCOM 1-425-774-6600 FOR ADDITIONAL INFORMATION. STRUCTURAL CEILING SUSPENDED CEILING [FININSHED FLOOR TELECOM CONDUIT DETAIL SCALE: NONE ( WALL TELECOM OUTLET DEVICES AND COVERPLATE. ALL WALL OUTLETS SHALL BE MOUNTED AT SAME HEIGHT AS ADJACENT POWER OUTLETS UNLESS OTHERWISE NOTE. 02 STUB OUT 1" CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE PLASTIC BUSHINGS FOR ALL CONDUIT ENDS. 120VAC POWER 5 NPP2OPLBP CONTROL RECEPTACLE PLUG LOAD CIRCUIT # SWITCHED RECEPTACLES SS bo o �$ o'' e I) foo TO NEXT S SWITCHED RECEPTACLE J SPLIT CONTROLLED RECEPTACLE DETAIL SCALE: NONE TO NEXT NON -SWITCH RECEPTACLE NOTE: 1. PROVIDE ALL DEVICES, J -BOXES, CONDUIT, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. 2. REFER TO ELECTRICAL POWER & LIGHTING PLAN SHEETS FOR DEVICE QUANTITY. 3. PROVIDE SPLIT CONTROLLED RECEPTACLE WITH CONTROL SYMBOL AND "CONTROLLED" ABOVE OR SIDE OF THE CONTROLLED OUTLET. PART NUMBER LEVITON 5262-S1G OR EQUAL. 4. OCCUPANCY SENSOR WILL CONTROL THE SWITCHED RECEPTACLE. DUAL RJ -45 JACK INSERT FOR UTP JACK IDENTIFICATION ;ACK IDENTIFICATION IDF-A-1-1 IDF-A-1-2 BLANK FILLERPLATE LABEL 16 POINT TYPE LETTERING BLACK ON WHITE DUAL RJ -45 JACK INSERT FOR UTP DUAL RJ -45 JACK INSERT FOR UTP SINGLE GANG FACEPLATE NOTES: 1. PROVIDE DOUBLE GANG COVERPLATES IN AREAS REQUIRING MORE DROPS THEN WILL FIT INTO A SINGLE GANG PLATE. 2. PROVIDE 5 SQUARE BACK BOXES AT ALL TELECOM OUTLET LOCATIONS. 3. DETAILS ARE SHOWN AS A GUIDELINE AND ARE NOT A REPRESENTATION OF EVERY SITUATION. 4. SEE SPECIFICATION SECTION 271000 FOR MORE REQUIREMENTS. 5. SEE FLOOR PLANS WHERE SUB -NUMBER IN SYMBOL INDICATES QUANTITIES OF DROPS PER OUTLET. TYPICAL TELECOM WALL OUTLET DETAILS SCALE: NONE r EXISTING EQUIPMENT 1,000000 000000 000000 000000 I 11 000000 000000 000000 000000 r - L - 1 -J J T EXISTING EQUIPMENT OPEN SPACE T EXISTINGI EQUIP. L L J J UTP CABLE SCHEDULE TYPE DESCRIPTION REMARKS 01 FOUR PAIR UTP CATEGORY 6 CABLE FOR DATA, DATA, QUANTITY PER DEVICE AS NOTED ON FLOOR PLANS 1,2 SCHEDULE NOTES: AT 1. UTP CABLE ROUTED FROM OUTLETS IN CONDUITS TO ACCESSIBLE CEILING SPACE THEN THROUGH J—HOOKS TO TELECOM RACK. 2. ALL TELECOMMUNICATION CABLES SHALL BE TERMINATED A PATCH PANEL. DETAIL NOTES SEE FLOOR PLANS FOR LOCATIONS OF TELECOMMUNICATION OUTLETS. PROVIDE QUANTITY OF CAT 6 DROPS PER OUTLET AS INDICATED INSIDE TELECOM SYMBOL ON FLOOR PLANS. ALL CABLING WILL PUNCH DOWN ON PATCH PANELS IN THE IDF-A. SEE THIS SHEET AND SPECIFICATION 271000 FOR ADDITIONAL OUTLET REQUIREMENTS. O2 EXISTING FREE STANDING UPRIGHT FLOOR MOUNTED RACK. O PROVIDE UTP WIRE MANAGEMENT PANELS AS SHOWN PER SPECIFICATION SECTION 271000. 0 PROVIDE RACK MOUNTED CAT. 6 HIGH DENSITY PATCH PANEL PER SPECIFICATION SECTION 271000 AND TERMINATE ALL UTP CABLES. O5 PROVIDE SHELF FOR AIPHONE CENTRAL EXCHANGE UNIT. OR -60400405. 0 PROVIDE AIPHONE CENTRAL EXCHANGE UNIT. SEE NOTE 19 SHEET CE3.01. EXISTING TELECOM RACK IDF-A ROOM A111 SCALE: NONE NPODMDX WALL SWITCH 0 TOPLIGHT ZONE 1 WHITE BLACK ORANGE BLUE BLUE VIOLET GRAY NCMPDT9ARRJB CEILING MOUNT OCCUPANCY SENSOR v NCMADCXDZRJB CEILING MOUNT DUAL ZONE PHOTO CELL NPP16D 0 TOPLIGHT ZONE 2 WHITE BLACK ORANGE BLUE BLUE VIOLET GRAY v NPODMDX WALL SWITCH NCMPDT9ARRJB CEILING MOUNT OCCUPANCY SENSOR NPP2OPLBP )))) Q B�WHITE BLACK BLUE BLUE SWITCHED RECEPTACLE CONTROLLER POWER PACK m NCMADCXDZRJB NCMADCXDZRJB CEILING MOUNT DUAL ZONE PHOTO CELL NCMPDT9ARRJB CEILING MOUNT OCCUPANCY SENSOR WHITE BLACK ORANGE BLUE BLUE VIOLET GRAY LIGHTING ROOM CONTROLLER DIMMING POWER PACK OFFICE LIG ITING/RECEPTACLE CONTROL ID1A6 4M NTS NOTE: PROVIDE ALL DEVICES, CONDUITS, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. THIS DIAGRAM MAY NOT REPRESENT EACH ROOM/SPACE/AREA EXACTLY PROVIDE ALL DEVICES AS REQUIRED FOR EACH LOCATION. CEILING MOUNT DUAL ZONE PHOTO CELL CAFE TERIA EXi='ANS ION L IGHT CONTROL D IAG AM NTS NOTE: PROVIDE ALL DEVICES, DEVICES, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. THIS DIAGRAM MAY NOT REPRESENT EACH ROOM/SPACE/AREA EXACTLY PROVIDE ALL DEVICES AS REQUIRED FOR EACH LOCATION. NPP16D 0 TOPLIGHT ZONE 3 WHITE BLACK ORANGE BLUE BLUE VIOLET GRAY NCMPDT9ARRJB CEILING MOUNT OCCUPANCY SENSOR NCMADCXDZRJB NPP16D 0 WHITE BLACK ORANGE BLUE BLUE VIOLET GRAY LIGHTING ROOM CONTROLLER DIMMING POWER PACK REVIEWED .FOR COMPLIANCE WITH NEPA 70 NEC MAY 2 6 2017 City of Tukwila BUILDING DIVISION CEILING MOUNT DUAL ZONE PHOTO CELL NPODMDX EC EV1(AL bSWITCH -..'T\ ;-)F•TUKWIL/ A 2 5 2017 WIRE LEGEND r CENTER CAT 5-E (CLASS 2) LINE VOLTAGE 0 10 VDC LOW VOLTAGE (1A @ 40 VDC/VAC) 15-24 VDC POWER ETHERNET LAN (CLASS 2) 308 architect r()Iluda architecture planning interior design. 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com >— z(i) w 2p J E— LI.I < 0 W Z > W/ W rx co • Ocij Wrn o0z V) ..J. M <CU g O (n � 2 w z 0 REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR Issuance PERMIT SET . Date: 4/14/2017. Drawing Title LIGHTING/RECEP CONTROL DIAGRAM Drawing Number CE8.03 CE8.03_LIGHTING-POWER CONTROL DIAGRAM.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC'