Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL17-0337 - NGUYEN RESIDENCE - SOLAR SYSTEM
NGUYEN RESIDENCE 4635 S 148 ST EL17.0337 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Website: http://www.TukwilaWA.gov ELECTRICAL PERMIT 0042000136 Permit Number: 4635 S 148TH ST NGUYEN RESIDENCE Issue Date: Permit Expires On: EL17-0337 5/23/2017 11/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NGUYEN JIMMY+BUI AMY NGAN 4635 S 148TH ST, TUKWILA, WA, 98168 JESSE ANDERSON 2444 FIRST AVE S , SEATTLE, WA, 98134 A&R SOLAR 2444 FIRST AVE S , SEATTLE, WA, 98134 RSO LAS * 903J M I Phone: (206) 317-4656 Phone: (206) 707-9937 Expiration Date: 5/20/2018 DESCRIPTION OF WORK: INSTALL AN 8.69 KW PHOTOVOLTAIC SYSTEM ON THE ROOF Valuation of single family: $16,345.00 Valuation of mf/comm: $0.00 Type of Work: REMODEL Fees Collected: $111.87 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: S?3`r7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: p'` Print Name: c�''��3' �_ Avt_ ,,�-'sem Date: 5./2.3/l? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. 1 037 Project No. Date Application Accepted: 5 :3 — 17 Date Application Expires: Lt (7 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4635 S 148th St. Tenant Name: Nguyen King Co Assessor's Tax No.: Suite Number: Floor: PROPERTY OWNER Name: Jesse Anderson Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Name: Jimmy Nguyen Email: permits@a-rsolar.com Tukwila Business License No.; BUS -0996237 Address: 4635 S 148th St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jesse Anderson Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: (206) 707-9937 Email: permits@a-rsolar.com New Tenant: ❑ Yes ® ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: A and R Solar SPC Address: 3211 Martin Luther King Jr. Way S, Suite B Cin': Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: Contr Reg No.: RSOLAR*903JM Exp Date: 05/20/2018 Tukwila Business License No.; BUS -0996237 Valuation of Project (contractor's bid price): $ 16,345 Scope of Work (please provide detailed information): Installing a 8.69kW Photovoltaic System on the roof Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes No Type of Use: Grid Tied Solar System Type of work: ❑ New m Addition ❑ Service Change ❑ Remodel 0 Tenant Improvement ❑ Low Voltage 0 Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ® Seattle City Light W:\Permit Center\Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised I-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) O Garages, pools, spas and outbuildings $83.54 ea O Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $83.54 (no added/altered circuits) O Service change with added/altered circuits $83.54 number of added circuits $12.00 ea V] Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) O Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Jesse Anderson Day Telephone: (360) 310-0260 Date: 5-7c7/ Mailing Address: 3211 Martin Luther King Jr way S, Suite B. Seattle, WA 98144 City W -.\Permit Center\Applications-Handouts \Permit Applications\PDFs\Electrical Permit Application Revised 1-1-17. docx Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK$111.87 ACCOUNT QUANTITY PAID EL17-0337 Address: 4635 S 148TH ST Apn: 0042000136 $111.87 Credit Card Fee $3.26 Credit Card Fee R000,369.908.00.00 0.00 $3.26 ELECTRICAL $104.43 PLAN CHECK FEE R000.345.832.00.00 0.00 $20.89 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $83.54 TECHNOLOGY FEE $4.18 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11431 R000.322.900.04.00 0.00 $4.18 $111.87 Date Paid: Friday, May 05, 2017 Paid By: JESSE ANDERSON Pay Method: CREDIT CARD 06296J Printed: Friday, May 05, 2017 11:44 AM 1 of 1 CI SYSTEMS INSPECTION RECORD Retain a copy with permit613 37 INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ,DUY� I3 e Type of Inspection: eN AV Address: Lf / /X5 _o!ixsr�. Date Called: Special Instructions: l. " / r b 1 v 3.0 + 7'!! Date Wanted:// 2-4 COD p.m. Requester: / Phone No: q T 72-‘ ( Approved per applicable codes. Corrections required prior to approval. COMMENTS: OX Inspector: 6e4J6 Date: 05,.. ( Th 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. LIOZ 'b A214 v7 3 CD 8.96kW SOLAR PHOTOVOLTAIC SYSTEM SCL GENERATOR Solar PV Array Module: LG 320w Power Output: 320 Watts (DC) Qty: 28 Modules Total Max Output: 8.96kW DC Location: Roof top SOLAR EDGE Power Optimizer (28) P320 SE Power Optimizer Vmp Input Range: 8-48 V (DC) Max Output: 60V(DC) Max Output Current: 15A (DC) Each string: 2 conductors, #10 in 3/4" EMT Max output voltage: 350V Max Output Current: 15A (DC) V(OC) = (1V per SE P300 optimizer) CENTRAL INVERTER Solar Edge SE7600A-US Max Output: 76000 W AC Output Voltage: 240VAC Max Output Current: 32A Rapid Shutdown compliant NEC 690.12 #6 GEC PRODUCTION METER Rating: 100 A AC Location: Co -located with meter • • • • • ■ String 1 14 modules String 2 14 modules Total System Voltage Drop: 0.76% +/- (3 conductors) #8 in 3/4" EMT #10 EGC Line Load REVIEWED FOR COMPLIANCE WITH NFPA 70 Q NEC MAY 132017 1tyy of Tukwila BUILDING DIVISION rrnn- rn? 520 mz��o 70z--165; mo- ZDOxZ <ZxDG) �rZn =znoo OG)m- - 1 -1- mm� mOOmm mC(n prn0II -1O.4pm niCO (gym InZ 0 — fr ;ni m-1 `"Om Z O n Z Z 0 3�D > Z D N G7-,ZT O• xZO3 • D00-1 D r X Z O 0 xi rrn 0 SERVICE METER RECEIVED CITY OF TUKWILA MAY 05 2017 PERMIT CENTER MAIN SERVICE PANEL Rating: 200 A / 240 V AC Main Breaker: 200 A Solar OCPD: 2p40 L173 0337 Customer: Address: Jimmy Nguyen 4635 S 148th St Tukwila, WA 98168 Phone Number: Project Mgr: Phone: (206) 459-8265 Will MacArthur (206) 307-1741 A&RSoIa r 2444 1st Ave South, Seattle, WA 98134 (800) 714-1834 RECEIVED CITY OF TUKWILA MAY 05 2017 PERMIT CENTER B. 'e^88: 8 i E E m, ^oho , ZA gg Temp Adj. CS6U34SM .34. f a osto O E a 8 V Par 18Rg? . 8S5rn�ar A Emgo F u pp. 'Y 3 Panel Specs I0420 S 11 Z L a_�,$o 3mo = 3 GEC Sin' per 250.65 EGG protected? [FOC sire 'per 230.122 y I 1 i> a w Q N >. a Inverter Mppt Input E E t> Voltage Wog) Max Amps Dec) _ @ i r _ 0 9 § to 3 o 9 s a ; C m a u Z H �m 2mf y 1 a xg i Combined Inverter OCO 51:e 15 B W till/ a .000 > .A o kgry s x e s�.m a Opening Current Imp 1 33' 33 Total Voltap Drop: 0C Vo0age Drop: AC Vo0age Drop: Sfl-V003L3S a093 0905 F.23' [AC Comb. Mae Amps Out 1 32 1 3 I f 000 00 li urn 3 t 3 8888 8~ s 33 'Inverter Specs Inverter Output Voltage Inverter Mae Amps Out a C , Y C 0 ; P. z a tl n 000 agg, E Nominal Vo0age ,6g 4. 6LQ_ n " "Z Cu CU 8 Y rst t c rI n Afre.ate Output Site Conditions r68P s I. 3 8- - 3-3, Number of Modules per Mppt I ed oral Number of Modules 2 Number of Inverters Wire Ampacity b 3 THHN, THWN, TNWN-2 THNN, THW N, THW N-2 TENN, THWN, THWN-2 (Voltage Drop _ I88ki 3 0 Notes ASHRAE Site: Lowest Record Ambient Temp) 5) E •E a E A 'Equipment Mppt Input Module KB Id Stringl to Invertarl Strine2 tolnverterl dSW OO souardI i tt C C` Zt Inverter to MSS RECEIVED CITY OF TUKWILA MAY 05 2017 PERMIT CENTER Nguyen Roof Layout 1I cn E C Y to E. (.) Al • C .r � o co Z '13 • Eco a 7 �� a x c 47 to 0 to May 4, 2017 Nguyen Roof Layout OF TUKW CITYILA MAY 0 5 2017 RMIT CENTER Photovoltaic Array voduct 12 years • r%5rraoN LG Life's Good Innovation for a Better Life Power 25 years rrm,1 LG NeONr 2 60 cell ••• Better Performance on a Sunny Day LG NeONT3 2 now performs better on sunny days thanks to its improved temperature coefficiency. LG320N1C-G4 LG315N1C-G4 LG's new module, LG NeONTTM 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. LG NeONTM 2 demonstrates LG's efforts to increase customer's values beyond efficiency. It features enhanced warranty, durability, performance under real environment, and aesthetic design suitable for roofs. Enhanced Performance Warranty LG NeONT"" 2 has an enhanced performance warranty. The annual degradation has fallen from-0.7%/yr to -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p more output than the previous LG NeONTM modules. Aesthetic Roof LG NeONT"' 2 has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may help increase the value of a property with its modern design. About LG Electronics LG310N1C-G4 LG305N1C-G4 C E C(E1 )US Intertek APPROVED PRODUCT KM 554573 3SEN61215 Photovo,taic Ma;ules . High Power Output Compared with previous models, the LG NeONTM 2 has been designed to significantly enhance its output efficiency, thereby making it efficient even in limited space. Outstanding Durability With its newly reinforced frame design, LG has extended the warranty of the LG NeONTM 2 for an additional 2 years. Additionally, LG NeONTM 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. Double -Sided Cell Structure The rear of the cell used in LG NeONT"" 2 will contribute to generation, just like the front; the light beam reflected from the rear of the module is reabsorbeRECE1V =D amount of additional power. CITY OF TUKWILA MAY 05 2017 LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi -conductor, LCD, chemistry, and materials industry. We successfully released first Mono X® series to the market in 2010, e:io R the following 2 years, thereafter. In 2013, NeON" (previously known as Mono X® NeON) & 201 5 Ne0N2 with CELLO technology won "Intersolar Award", which proved L is e ea nAAova industry. LG NeON''2 LG320N 1 C -G4 1G315N1C-G4 LG310N1C-G4 LG305N1C-G4' Mechanical Properties Electrical Properties (STC *) Cells 6 x 10 Module Type 320 W 315 W 310 W 305 W Cell Vendor LG MPP Voltage (Vmpp) 33.6 33.2 32.8 32.5 Cell Type Monocrystalline / N -type MPP Current (Impp) 9.53 9.50 9.45 9.39 Cell Dimensions 156.75 x 156.75 mm / 6 inches Open Circuit Voltage (Voc) 40.9 40.6 40.4 40.1 a of Busbar 12 (Multi Wire Busbar) Q Short Circuit Current (Isc) 10.05 10.02 9.96 9.93 Dimensions (L x W x H) 1640 x 1000 x 40 mm Module Efficiency (%) 19.5 19.2 18.9 18.6 64.57 x 39.37 x 1.57 inch Operating Temperature ('C) -40 - +90 Front Load 6000 Pa / 125 psf Maximum System Voltage (V) 1000 Rear Load 5400 Pa / 113 psf Maximum Series Fuse Rating (A) 20 Weight 17.0 ± 0.5 kg / 37.48 ± 1.1 lbs Power Tolerance (%) 0 - +3 Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm/ 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications • STC (Standard Test Condition): Irradiance 1000 W/m', Module Temperature 25 °C, AM 1.5 • The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. •The typical change in module efficiently at 200 W/m' in relation to 1000 W/m' is -2.09fi. Electrical Properties (NOCT*) Module Type 320 W 315 W 310 W 305 W Maximum Power (Pmax) 234 230 226 223 IEC 61215, IEC 61730-1/-2 MPP Voltage (Vmpp) 30.7 30.4 30.0 29.7 IEC 62716 (Ammonia Test) MPP Current (Impp) 7.60 7.58 7.54 7.49 IEC 61701 (Salt Mist Corrosion Test) Open Circuit Voltage (Voc) 37.9 37.6 37.4 37.1 ISO 9001 Short Circuit Current (Isc) 8.10 8.08 8.03 8.01 UL 1703 • NOCT (Nominal Operating Cell Temperature), Irradiance 800 W/m', ambient temperature 20 °C, wind speed 1 m/s Module Fire Performance (USA) Type 2 (UL 1703) Fire Rating (for CANADA) Class C (ULC/ORD C1703) Product Warranty 12 years Output Warranty of Pmax Linear warranty* 40 • 1) 1st year 9898, 2) After 2nd year 0.6%p annual degradation, 3) 83.656 for 25 years Temperature Characteristics NOCT 46±3°C Pmpp Voc Isc -0.38 %/°C $w -0.28 %/°C 0.03 %/°C Characteristic Curves E 1000 eao 6 600 400 200 000 5.00 1000 15.00 2000 25.00 3000 35.00 4000 45.00 Voltage (5) 0LoGwed North America Solar Business Team LG Electronics U.S.A. Inc 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: Ig.solar@lge.com www.igsolarusa.com Dimensions (mm/in) SS 0 0414 4.40,4404.0\ MO/ 00 32 N°,nw Mn(r o•t.ly on>,2 .14 960 /37.e0 40/1 57 EC@IVE UK ILA AY 0 5 20 • The distance between the center of the mou g grounding ales Product specifications are subject to char•.ge without notice. DS -N2 -60 -C -G -F -EN -50427 PERMIT ..�T Copyright © 2016 LG Electronics. All rights reserved. Innovation for a Better.Life 01/01/2076 t a solar-.. SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US _ The best choice for SolarEdge enabled systems Jr Integrated arc fault protection for NEC 2011 690.11 compliance Rapid shutdown for NEC 2014 690.12 — Superior efficiency (98%) — Small, lightweight and easy to install on provided bracket Built-in module -level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre -assembled Safety Switch for faster installation — Optional — revenue grade data, ANSI C12.1 USA - GERMANY - ITALY - FRANCE -JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL RECEIVED CITY OF TUKWILA MAY 05 2011 PERMIT CENTER www.solaredge.us Single Phase Inverters for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US 5E3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A- US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 Max. AC Power Output AC Output Voltage Min: Nom: Max 111 183 - 208 - 229 Vac AC Output Voltage Min: Nom: Max 1i1 211-240-264 Vac AC Frequency Min: Nom: Max 111 Max. Continuous Output Current GFDI Threshold 3300 4150 5000 6000 7600 5400 @ 208V 5450 9240V 6000 8350 9980 @ 208V 10000 @240V 11400 10800 @ 208V 10950 @ 240V ✓ 12000 VA VA 59.3-60-60.5 Hz 12.5 16 24 @ 208V 21 @ 240V 25 32 48 @ 208V 1 42 @ 240V 47.5 A A Utility Monitoring, Islanding Protection, Country Configurable Thresholds INPUT Yes Yes Maximum DC Power(STC) Transformer -less, Ungrounded Max. Input Voltage 4050 5100 6750 8100 Yes 10250 I 13500 15350 500 Vdc Nom. DC Input Voltage Max. Input Current121 Max. Input Short Circuit Current 325 @ 208V /350 @ 240V Vdc 9.5 13 16.5 @ 208V f 18 15.5 @ 240V 23 33 @ 208V 30.5 @ 240V 34.5 Adc 45 Reverse -Polarity Protection Ground -Fault Isolation Detection Maximum Inverter Efficiency 97.7 98.2 CEC Weighted Efficiency Nighttime Power Consumption ADDITIONAL FEATURES Supported Communication Interfaces 97.5 98 Yes 600ka Sensitiv'ty 98.3 98.3 98 97 @ 208V 98 @ 240V < 2.5 97.5 97.5 98 98 97 @ 208V 97.5 @ 240V 97.5 Adc % <4 W Revenue Grade Data, ANSI C12.1 Rapid Shutdown - NEC 2014 690.12 STANDARD COMPLIANCE Safety RS485, RS232, Ethernet, ZigBee (optional) Optional131 Yes Grid Connection Standards Emissions UL1741, UL1699B, UL1998, CSA 22.2 IEEE1547 FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG DC input conduit size /# of strings / AWG range Dimensions with Safety Switch (HxWxD) Weight with Safety Switch Cooling Noise 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-3 strings / 14-6 AWG 30.5 x 12.5 x 7.2 / 775 x 315 x 184 30.5 x 12.5 x 10.5 / 775 x 315 x 260 in / mm 51.2 / 23.2 54.7 / 24.7 88.4/40.1 Ib/kg Natural Convection < 25 Natural convection and internal fan (user replaceable) Fans (user replaceable) < 50 Min. -Max. Operating Temperature Range Protection Rating -13 to +140 / -25 to +60 (-40 to +60 version available )) RECE1 CITY OF T NEMA 3R Irl For other regional settings please contact SolarEdge support. PI A higher current source may be used; the Inverter will limit Its input current to the values stated. ISI Revenue grade Inverter P/N: SExvxvA-USOOONNR2 (for 7600W inverter:SE7600A-US002NNR2). NI -40 version P/N: SExxxvA-US000NNU4 (for 7600W inverter:SE7600A-US002NNU4). BILA MAY 0 5 2617 PERMIT CENTER ® SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE. the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2016. V.02. Subject to change without notice. Quick PV YourSolut!on in Mounting Products Solar • H2O • Conduit • HVAC • Custom Curved Tile Mount Specifications Racking of Choice (E) 12"x 17" Curved -Tile All Patents Pending EPDM Counter Flashing Flexible Aluminum Flashing Cut Tile 5/16"x 1" Machine Bolt (Stainless Steel) For Rack Attachment 5/16" Washer (Stainless Steel) 5/16"x 1 1/4" Sealing Washer (Stainless Steel ) Field Applied Appropriate Sealant 1 1/4"x 5 1/2"Aluminum Post 5/16"x 3/4"Machine Bolt (Grade 8) Cast Aluminum Base Plate Peel and Stick Flashing - Under paper above 7 -- J (E) Plywood Sheathing (E) Tar Paper (E) Batton 6" Lip of Tile to Center of Post 2 each 5/16"x 3 1/2" Lag Bolts Lag Bolt Specifications Specific 5/16" shaft 5/16" shaft gravity 3" thread depth 1" thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir. (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: Uniform Building Code; American Wood Council Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) Pull-out values incorporate a 1.6 safety factor recommended by the American Wood Council. 3) See UBC for required edge distances. **Note: To maintain waterproofing of substrate it is important to make sure the Peel and Stick Flashing is properly placed over the Mount Base, and under the course of paper above. If the paper above does not reach due to layout, place an additional piece of roofing paper over the Peel and Stick and under the next course of paper above. (See instructions page 4) 1 (E) 2 x Rafters Installation Tools Required: Tape Measure Drill with 1/4"wood bit Ratchet w/ 1/2" Socket Caulking Gun 1 Tube of Appropriate Sealant 30 Ib felt paper Wisk broom /Vacuum Roofers Bh/thatinErD CITY OF TUKWILA Know Your Roof It is a good idea to do a thorough roof evaluation prior to your project installation. At this time you should do a layout on the roof confirming everything on the drawing will fit as it is intended. Any irregularities should be noted now, so that you can deal with them simply on install day. The quality of the roofing should be determined, so that any repairs or replacement can happen before or in conjunction with the installation. Remove a tile and see what is underneath. On a tile roof it is important to know as much as possible about: the manufacturer of the tile, the size of the tile, age of tile, type of substrate (plywood or oriented strand board [OSB]) the rafter size and spacing, age of roof structure, who roofed it, who built it, etc. Photos should be taken of all of the roof variables and associated with the job file for any future reference either short term or long. If the roof- ing manufacturer is known, it is then easy to obtain the written manufacturer's installation instructions for the roofing materials you are dealing with. Typically the tile roof manufacturer puts a stamp of some sort on the back of each tile. This stamp can be defined by the roofing yard, or by a little on-line surfing. The manufacturer's instructions will spell out exactly what does and does not void the warranty of their roofing product. Officially, the roofing manufacturer's instructions supersede our instructions, as our product is weaving into theirs. It is also important to have their instructions in the job file, for any future reference. Product Selection The Quick Mount Curved Tile Mount is intended to fit within most curved tile roof systems, as well as most flat tile systems. Specifically it is sized to fit within a standard 12" wide x 17" tall concrete tile roof system of either standard weight or Tight weight, and flat or curved. It is used on Flat Tile roofs when the engineer or building department requires rafter mounting. It is used on most any Curved Tile roof and rafter mounted as a standard. Height extensions are not for use with this product. Custom lengths can be ordered. (Coming Soon: Curved Tile Instructional Video at www.quickmountpv.com/tech.php) Waterproofing On a tile roof it is actually the building paper below the tiles that is waterproof. The tiles are considered water resistant. It is assumed that water will travel under the tiles. The tiles are there for aesthetics, thermal absorbtion, and to protect the building paper from U.V. and the elements. It is imperative to follow standard roofing practices with the paper. The Peel and Stick Flashing that we provide needs to go over our Mounting Base Plate with 1" minimum sticking to the roof paper below the mount. On the top side of the mount, the Peel and Stick must extend under the existing lap in the paper course directly above the mount. In the common occurrence that the paper is too far up the roof to reach, you must supply and install another piece of building paper (usually 30 Ib.) under the row of paper above, and over the top 2 inches of Peel and Stick Flashing. This paper should be wider than the Peel and Stick Flashing, and either stapled down or nailed. If a baton board is in the way, pry it up and slip the paper under the baton. How Many Mounts Per Module? There are two questions that must be asked when adding anything to a roof. 1. Can the roof / building / foundation handle the additional load? 2. What is to keep the new load from blowing away? It is assumed that a licensed solar installer can answer these questions. If he / she can't, he / she will need to find somebody that can. A licensed engineer is the easiest solution. Some of the racking manufacturers have guides to calculating a code compliant install as well. Many vari- ables must be considered and determined to complete the calculation. The spacing between mounts has the variables of: strength of rail, dis- tance between parallel rails, cantilever of modules over rails, pull out strength of mount, slope of roof, height of roof, wind zone, roof type, structural integrety of roof framing, etc. The only values in the variables above that we can provide is pull out strength and shear of mount. We provide structural test reports on all of our mounts as needed. You will need to do the calculation of variables as you are the only one who knows them all. Further Resources In the process of all the research we have done, we came up with what we call the "Wheel of Accountability". It is a graphical look at the many official entities that govern how waterproofing should be done. At our web site you can click on any wedge of the wheel and get the code snip- pets that pertain to that entity's focus on roof penetrations. Please don't hesitate to use it to your advantage. And of course if you have any feed back pro or con, let us have it. Take photo's of your jobs using Quick Mount Products and submit them to us, we'll put them up in our web gallery. Submit them to info@quickmountpv.com Subject - Gallery Photo 2 Product Includes The units are sold in 12 packs. Each 12 pack includes the mounting hardware, the mount, the substrate waterproofing, and the flashing to install 12 mounts, with written instructions. RECEIVED CITY OF TUKWILA National Roofing Contractors Association Asphalt Roofing Manufacturers Association Sheet Metal & Air Conditioning 5 Contractors' National Association AHJ Authority Having Jurisdiction National Fire Protection Q Association PR Racking of Choice (Not included) 5/16" Sealing Washer 5/16-18 x 3/4" SS Machine Bolt 5/16" ID Fender Washer EPDM Rubber Counter Flash 0 0 9.00 6.625 18.00 J 18.00 Bendable Aluminum Flashing Peel and Stick Tape 12" x 12" Square 5/16" x 31/2" lag Bolts Base Plate Cas-Iuminum Fri Ba late 5.53b5" x 0.5" a( o 11 _m Z oSCI^^TI TY OF QUICf(.1410UNT *CI RIGHTS OF DESIGN OR INVENTION ARE RESERVED elm 5/16-18 x 1" Grade 8 Bolt TITLE: COMMENTS QMCTM Curve Tile Assembly Example of a QMCTM cover molded as if on two roof tiles FILE NAME QMCTM_2 DATE 9/24/09 REVISION DRAWN BY A.B.K. Quick Mount PVt Your Solution in Nou nti nProducts Solar • H=O • Conduit • HVAC • Custom 0\uic ount CURVED TILE MOUNTING INSTRUCTIONS RAFTER INSTALLATION Remove Tile at selected location of Mount. Locate center of rafter and Mark with a felt pen. Drill 1/4" pilot hole. Place Machine Bolt under Base Plate in hex slot, threads pointing up. Lag Base Plate into Rafter on Marks. Carefully clean the building paper then install Peel and Stick Flashing over stud and up roof to lap under the next row of base paper flashing. Install Post onto stud. Make sure Peel and Stick slides under existing building paper. For Questions Call 925-687-6686 QM -PV -Curved -Tile -Install Place Aluminum Flashing into position over Post & bend to contour of tiles. Apply Sealant around cone to Post. Slide on EPDM Counter Flashing. Seal top of Post with 1 1/4" Sealing Washer. www.quickmountpv.com 4 Use a straight edge and measure up 6 5/8" from bottom of tiles to center of the Mount, over the center of Rafter. Take care to do a quality installation — see im- portant notes *(below) and **(pgl). Firmly press Peel and Stick Flashing to Base and paper; work from center out removing any air pockets. You are now ready for the rack of your choice. Follow all the directions of the rack manufacturer as well as the module manufacturer. All roofing manufacturers' written instructions must also be followed by anyone modifying a roof system. Please consult tb rers' specs and instructions prii�` .'� oof. * Make sure the Peel Stick Tfirmly KaWILA and that all the air bubble antgcl l PERMIT CENTER info@quickmountpv.com May 2010 Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing mat. • 9 -•-i• i • • . • . . • . there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with Tight or no snow. It achieves 6 foot spans, while remaining light and economical. • 6' spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8' spanning capability • Heavy Toad capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12' spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow (PSFI None ' 1Vind(V1PH)''' 100 ' •(- 4,_ XR10 -...,.>��4' .M�i r..tik.ID4 6� " tMff 0i 14J\I `.ri �10,a "45 i yrp. 4k� XR1000 mi' •'12• '., L 1 y }}�i ` Y IE 120 140 — — XR100 160 f 10-20 100 120 140 160 30 100 RECEIVED- CITY OF TUKWI MAY-0-5-2 160 40 -10o i 160 50-70 160 I , �' t 80-90 160 4 -PERMIT`' CENT © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.13 A d�� IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. RECEIVED CITY OF TUKWILA MAY 05 2017 PERMIT -CENTER All XR Rails are made of 6000 -series aluminum alloy, then protected with an V]111 anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. +r� Corrosion -Resistant Materials Bid IRONRIDGE Datasheet Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20 -year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. iii PE Certified Pre -stamped engineering letters available in most states. Design Assistant RECEIVED CITY OF TUKWILA Online software makes it simple to create, share, and price Matta tta 5 2011 20 -Year Warranty PERMIT CENTER Twice the protection offered by competitors. XR Rails O XR10 Rail Datasheet A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish Clamps & Grounding O UFOs I -Tr Universal Fastening Objects bond modules to rails. • Fully assembled & tubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme Toad capability • Clear anodized finish Bonded Splices All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Grounding Lugs • Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Microinverter Kits Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources Slotted L -Feet Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Bonding Hardware Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated SZF,p'LII Ppoy NABCEP Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" I R EIVED • Ship n :kTUKWILA NABCEP Certified Training Earn free continuing edR while learning more about our systems. Go to IronRidge.com/training [• © 2016 IronRldge, Inc. All nghts reserved. Visit www.lronridge.com or call 1-800-227-9523 for more Information. Version 1.20 ���� ��� IRONRIDGE Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO Family of Components Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end damp. Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. RECEIVED CITY OF TUKWILA MAY 05 2017 ENTER Bonded Splice Each Bonded Splice uses self -drilling screws to form a secure connection. No bonding strap needed. Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Bonded Attachments The bonding bolt attaches and bonds the L -foot to the rail. It is installed with the same socket as the rest of the system. System Diagram O UFO Stopper Sleeve • Grounding Lug Bonded Splice Ground Wire Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. Q Go to IronRidge.com/UFO 2016 IronRidge, Inc. All nghts -served. RECEIVE Visit www.ironndge.com or call 1-800-227-9523 for more information. ILA ER Cross- y ,, TUKVtl • „ • . • *C17 Ger Mount Mount G ,w; c'o i XR Rails d d XR1000 Only UFO/Stopper v v ERMIb CENT Bonded Splice v ./ N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. Visit www.ironndge.com or call 1-800-227-9523 for more information. ILA ER /�� IRONRIDGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating—the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Testing Process Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burning Brand Test A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Spread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. 'Class A rated PV systems can be installed on Cfass A, 8, and C roofs A R Roof Slope f Module Rating Flush Mount n ® Any Slope Type 1, 2, & 3 EC' IVSD CI ,y�'TUKW1 Tilt Mount h.h. s 6 Degrees Type 1, 2, & 3 Pfiggc CENT n 'Class A rated PV systems can be installed on Cfass A, 8, and C roofs A R Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Cra 's 0, o t e jurisdiction now requires Class A or B?ro Generatly,°-otder-roofs-witt-typicallybe "grandfathered in", and will not require re -roofing. However, if 50% or more of thie`r"oofingmaterial is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the'sane fire classification as the roof assembly required by Section 1505. tit!'t'rt��`y r Gait.: Where is a Class A Fire Rating required? LMICLItUd The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. �. ---------- r. 2If0.81V2n ��.6 ra r:. r fl'` rte ♦ r Are standard mid clamps covered? ;r. Mid clamps and end clamps are considered part of the PV "system" and are covered in the certification. ---._. More Resources Tech Brief What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class A fire rating without any additional racking components. - -.11 -- -- ---- What determines Fire Classification? ' 1 I • Fire Classification refers to a fire -resistance rating system for roof covering materials basedlon their ability to withstand fire exposure. C Class A - effective against severe fire exposure, Class B - effective against.moderate fire exposure Class C - effective against'light fire exposure What if the roof covering is not Class A rated? . The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. Go to IronRidge.com RECEIVED CITY OF TUKWILA MAY -0 5 2017 Engineering CertificatioXett'ers CENTER We offer complete engineering resources and pre -stamped certification letters. Go to IronRidge.com © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 FILE COPY Permit No. 0/11/OVII Plan revicw 13 subject to errors and omissions. Approval of consTi.:f,tion documents does not authcrize the violation of my adopted code or ordnance. Receipt of approved FEJid Copy and conditions is acknowledgal: By: 4e---d-v-" Date: 572- 3 / ? City of Tukwila BUILDING DIVISION rNREVISIONS o chanp.es shall he made to the scope of work wit.h.7.0::;- prior approval of Tu,'c.,.,./,17.- r:-.-?,,,,4ic-cl L');vi..•;(,)il L. 7: 1-1.0i-13 1,Viii i...--.; r.! n'-', pn submittal nd mayer..Vonal p::;.n r7‘,'.•,-:, ------.........„___ PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL 17-0337 PROJECT. NAME: NGUYEN RESIDENCE SITE ADDRESS: 4635 S 148 ST X Original Plan Submittal Response to Correction Letter # DATE: 05/05/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 10 M4- Building Division Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/09/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/06/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoninglssues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 A&R Solar Home Espanol Contact Safety & Health Claims & Insurance A°)Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z' Index Help My L&1 Workplace Rights Trades & Licensing A&R Solar Owner or tradesperson Principals CLIPPARD, WILLIAM R, PRESIDENT YATTEAU, ANDREW, VICE PRESIDENT CLIPPARD, WILLIAM R, AGENT Doing business as A&R Solar WA UBI No. 602 707 872 Parent company A AND R SOLAR CORP 2444 1st ave s SEATTLE, WA 98134 206-707-9937 KING County Business type Corporation Governing persons ANDREW YATTEAU DAVID KOZIN; EVAN MANDERBACH; WILLIAM CLIPPARD; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. RSOLAS*903JM • Effective — expiration 05/20/2010— 05/20/2018 Designated administrator Clippard, William Active. Meets current requirements. License type License no. Electrical Administrator CLIPPW'902JN Bond ................. CBIC Bond account no. S16249 $4,000.00 Received by L&I Effective date 05/20/2010 05/17/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations ...olicensevio.l.ai.... Help us improve No license violations during the previous 6 year period. P p https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 5/23/2017 A&R Solar Page 2 of 3 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 168,352-00 ............................. Doing business as A&R SOLAR Estimated workers reported Quarter 1 of Year 2017 "31 to 50 Workers" L&I account representative T3 / STEPHANIE I;NDERSON (360)902-5598 - Email: HSTE235@lni.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/26/2016 Inspection no. 317939903 Location 19 Main Street Soap Lake, WA 98851 Inspection results date 01/27/2016 Inspection no. 317938661 Location 507 123 Ave NE Bellevue, WA 98006 4j Inspection results date 12/03/2015 Inspection no. 317937464 Location N Barker Spokane Valley, VA 99216 Inspection results date 08/14/2015 Inspection no. 317937085 Location 10567 NE W. Kingston RD Kingston, WA 96346 Inspection results date 11/24/2014 Inspection no. 317607836 Location 12010 120th St�. W. • Lake Stevens, . 98258 Violations Violations Violations Violations Violations DWashington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secureini. Ara.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 5/23/2017