Loading...
HomeMy WebLinkAboutPermit EL17-0371 - VOGEL RESIDENCE - SOLAR SYSTEMVOGEL RESIDENCE 15030 43 PL S ELI 7-0371 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0042000265 15030 43RD PL S VOGEL RESIDENCE ELECTRICAL PERMIT Permit Number: EL17-0371 Issue Date: 6/22/2017 Permit Expires On: 12/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WORDEN SHANE P+VOGEL LAURIE 15030 43RD PL S , TUKWILA, WA, 98188 JESSE ANDERSON 2444 FIRST AVE S, SEATTLE, WA, 98134 A&R SOLAR 2444 FIRST AVE S , SEATTLE, WA, 98134 RSO LAS * 903J M Phone: (206) 317-4656 Phone: (206) 707-9937 Expiration Date: 5/20/2018 DESCRIPTION OF WORK: INSTALLING A 9.280 KW PHOTOVOLTAIC SYSTEM ON THE ROOF Valuation of single family: $14,023.00 Valuation of mf/comm: $0.00 Type of Work: REMODEL Fees Collected: $111.87 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition:. International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: . International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a d agree to the condiions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violationof the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvm.TukwilaWA.gov Electrical Permit No. E -L 17- on 7 1 Project No. Date Application Accepted: 5-1/-17 Date Application Expires: lig-n -1 7 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 15030 43rd P1. S Tenant Name: Vogel King Co Assessor's Tax No.: Suite Number: Floor: PROPERTY OWNER Name: Jesse Anderson Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Name: Laura Vogel Email: Permits@a-rsolar.com Tukwila Business License No.; BUS -0996237 Address: 15030 43rd Pl. S City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Jesse Anderson Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: (206) 707-9937 Email: Permits@a-rsolar.com New Tenant: D Yes ® ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: A and R Solar SPC Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: Contr Reg No.: RSOLAR*903JM Exp Date: 05/20/2018 Tukwila Business License No.; BUS -0996237 Valuation of Project (contractor's bid price): $ 14,023 Scope of Work (please provide detailed information): Installing a 9.280kW Photovoltaic System on the roof Will service be altered? ❑ Yes m No Type of Use: Grid Tied Solar System Adding more than 50 amps? ❑ Yes 123 No T pe of work: ❑ New m Addition 0 Service Change ❑ Low Voltage 0 Generator 0 Fire Alarm Property Served by: ❑ Puget Sound Energy ® Seattle City Light W:\Permit Center'Applications-Handouts\Permit Applications'J'DF's\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh ❑ Remodel ❑ Telecommunication O Tenant Improvement O Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $155.91 (including an attached garage) O Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea • Circuits added/altered without service change $55.69 (up to 5 circuits) O Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea O Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 O Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction —.In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature. Print Name: Jesse Anderson Date: Day Telephone: (360) 310-0260 Mailing Address: 3211 Martin Luther King Jr way S, Suite B. Seattle, WA 98144 City W:\Permit Center\Applications-Handouts\Permii Applications\PDFs\Electrical Permit Application Revised I-I-17.docx Revised: January 2017 bh State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY $111:87 EL17-0371 Address: 15030 43RD PL S Apn: 0042000265 $111.87 Credit Card Fee Credit Card Fee PLAN CHECK FEE PERMIT FEE SINGLE FAMILY TECHNOLOGY FEE TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11503 R000.369.908.00.00 R000.345.832.00.00 R000.322.101.00.00 R000.322.900.04.00 0.00 0.00 0.00 0.00 $3.26 $3.26 $20.89 $83.54 $4.18 $111.87 Date Paid: Wednesday, May 17, 2017 Paid By: JESSE ANDERSON Pay Method: CREDIT CARD 03253J Printed: Wednesday, May 17, 2017 11:31 AM 1 of 1 SYSTEMS INSPECTION RECORD ?� Retain a copy with permit M INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Voa� g6 a Type of Inspection: 0 Address: 15.3 3 p Date Called: Special Instructions: Date Wanted: / m Requester: aPPhone No:i '12c Ili 0 -72. - Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Inspector: Date: ©/ 3 q REINSPECTION FEE REQUIRED. Prior to next inspectio , fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY Permit No, 2 L1 l' 0 3Y1 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Rido+ :1 d +n+' '? acknowledged: By: Date: City of. Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: attecnanical 0 Electrical CI Plumbing CJas Piping City of Tukwila By'lIN ; DIVISION REVISIONS - No changes shall be made to the scope 7 ti of work witho tri r ?"�,!eti�,t,t p o approval of I a Ru.WOing Division. I`! T : 1:: sIliSi0;- will require a new plan submittal and may inckide additional plan review fees, ELI`1- 037 REVIEWED .FOR MPLIANCE WITH NFPA70NEC JUN 142011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 17 2017 PERMIT CENTER Vogel Roof Layout tU O. CO 3 rl u yo 15 _ EC O C y1 L L -V '� 3 tJ U y L o� -a=L L u {�N zo L c 0 fp O. May 9, 2017 0 REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC JUN 14 2017 City ©f.Tukwila LEILJIIDING DIVISlOiV Vogel Roof Layout ..Z/� b9Z RECEIVED CITY OF TUKWILA MAY 17 2011 PERMIT CENTER a1 id 0 2 Photovoltaic Array Module Specs Module Spacing (in) on Rail 0.25 Module 72 itek-300 81 Number of Modules Weight per Foot of Racking (lbs) 32 0.68 Module Orientation Portrait Number of Attachments Weight per Module (lbs) 36 Weight per Attachment (lbs) 43.0 Module Area (ft2) Combined total for Racking (lbs) 18.0 Length (in) 65.9 Width (in) 39.4 Array Information Module Spacing (in) on Rail 0.25 Attachments on Center (in) 72 Maximum Spacing Allowed (in) 81 Racking Information Total Weight (lbs) Racking Type IronRidgeXR100 577.5 Length of Racking (ft) 2.7 212 Weight per Foot of Racking (lbs) Distributed Load (lbs/Ift) 0.68 Attachment Type IronRidge Flash Foot Number of Attachments 36 Weight per Attachment (lbs) 1.4 Combined total for Racking (lbs) 192.76 Weights and Loads Total Weight (lbs) 1568.8 Total Area (ft2) 577.5 Total Dead Load (lbs/ft2) 2.7 Total Point Load (lbs) 43.6 Distributed Load (lbs/Ift) 25.5 Attachment Information Lag Dimensions 5/16" Shaft Lag Depth (in) 3.0 REVIEWED .FOR COMPLIANCE WITH NPPA70NEC JUN 142011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 17 2011 PERMIT CENTER N 0 0 ET 0 0 rr 111 0) .uinneaa auf al.u! 9.28 kleOLAR PHOTOVOLTAIC SY•M SCL GENERATOR Solar PV Array Module: itek 290 Power Output: 290 Watts (DC) Qty: 32 Modules Total Max Output: 9.28 kW DC Location: Roof top MICRO -INVERTER APS YC500-MIW* Max Output: 500 W AC Output Voltage: 240 VAC Max Output Current: 2.08 A Location: Attached to rail beneath modules Inverter Qty: 16 Total Max Current: 33.28A *Made in WA Rapid Shutdown Compliant ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ String 1 String 2 String 3 String 4 8 modules 8 modules 8 modules 8 modules Branches 1-4: 4 dual micro -inverters 12 conductors, #10 in 1" EMT AC SUBPANEL/COMBINER Rating: 100 A / 240 V AC OCPD Branch 1: 2p20 A OCPD Branch 2: 2p20 A OCPD Branch 3: 2p20 A OCPD Branch 4: 2p20 A PRODUCTION METER Rating: 100 A AC Location: Co -Located with Meter #6 GEC REVIEWED FOR �NFPA�iOCNEC� JUN 14 2011 Total Syste (3 conductors) #8 in 3/4" EMT #10EGC Line Load (3 conductors) #8 in 3/4" EMT #10EGC #6 GEC Ell SERVICE METER RECEIVED CITY OF TUKWILA MAY 17 2017 PERMIT CENTER MAIN SERVICE PANEL Rating: 200A/240VAC Main Breaker: 200 A Solar OCPD: 2p40 A Customer: Address: Laura Vogel 1530 43rd PI S Tukwila, WA 98118 Phone Number: Project Mgr: Phone: (907) 382-6894 Andy Yatteau 1425) 941-6272 A&RSoIa r 2444 1st Ave South, Seattle, WA 98134 (800) 714-1834 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC JUN 14 2017 City of Tukwila BUILDING_ DIVISION RECEIVED CITY OF TUKWILA MAY 17 2011 PERMIT CENTER E r « c 6 gg Itek-300 Temp Ad). T 20 ma .>^ a ass +%, i" T. g. a d 0000 6 25 o aset 0 W C d Ej jr>` e a E I 00'R',v Temp Adder RR.. G < t 61 C dv. Yw h > gr“oak» Ei2. z'—^ =2.i 5 ` =gy, ��te X�e ��tt 88 Grounding .0 S ti : Main Service �m,eV 9 a Q �' bE § E a p M m 0 APS Dual Mkro 240 2.1 _ IAC Comb. Mao Amps Out 1 33 I a aoo E�� No No Operating Current )Imp) l Total Vefbga Drop: OC Voltage Drop: AC Voltage Drop: P lx --- n e t 2z 8—'''' . Mao Continuous Current__ (inverter Specs rg 5Es gig Y C g s- '. --- § 2» E. .ERE o E. gR44 T. . gaa CU CU > MPPT1 1 Sidng Inverter Banti Aggregate Output �A gregate Output [Site Conditions r (Wire Ampacity x 3 THHN, THWN, TNWN-2 THHN, THWN, THWN-2 THHN, THWN, THWN-2 1 THHN, THWN, THWN-2 Voltage Drop One Way Length (11) Notes E I a 7 9 Average High Ambient Temp )'f) Record High Ambient Temp )'f) Equipment 1 f E Ip Mo0Wes per String 1 p Parallel Slrings Number of Modules per Mppt Total Number of Modules Numberol Invertor Note Stangl to 'menet Mkro To Combiner (Combiner to Production Meter Production Meter to MOP o 'Combiner to Production Meter Production Meter to MSP REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC JUN 14 2017 City of Tukwila BUILDING_ DIVISION RECEIVED CITY OF TUKWILA MAY 17 2011 PERMIT CENTER We offer solar modules of unsurpassed quality that exceed performance expectations at an affordable price. High -efficiency monocrystalline silicon PERC cells Certified PID -free above and beyond the industry standard 0 Full quality check of every module along the production line D Impact resistant, anti -glare solar glass Our Declare listing shows commitment to transparent, sustainable practices MAY 17 2011 REVI6NbciCbtillis• www.itekenergwa‘" a"Elpig . filletVENI y com COMPLIANCE WITH rare. -NEC 2011 —city otibkwila 'DIVISION . Itek Ene y SE Module Itek Ener y, LLC Assem y: Badingnam. WA. USA Lite Expycta .aOVea,s End of Lite WA) We Dec The Li ITh MADE IN AMERICA C.* US AND IMPORI LI) PARIS itetc ENERGY Building Solar 1 Powering The Future Itek SE 60 -Cell Solar Module Design & Engineering Data GENERAL DATA Cell Type • 60 high -efficiency monocrystalline p -type cells • 6 x 10 cell matrix Solar Glass • Ultra -clear anti -reflective treatment • Tempered, with low iron content • Anti -glare prismatic subsurface texture Backsheet • Multi -layered • Engineered adhesion for maximum weather protection Frame • High-strength corrosion -resistant anodized aluminum • Compatible with standard rocking, accommodating both top-down clamps and bottom -flange mounting Cable • 42" 90°C 12AWG PV wire Junction Box • 3 bypass diodes • 1000 VDC MC4 connectors Grounding • Certified for Wiley Electronics WEEBTM grounding clips • Eight standard grounding locations per module for reduced ground wire length Warranty • 25 -year power output • 12 -year workmanship QUALIFICATIONS UL Listing UL 1703 Fire Rating Type 2 PID Free 500+ hours ARRA, BAA, and TAA Compliant ELECTRICAL DATA* 295 SE 300 SE 305 SE Maximum Power - PAW (Wp) 295 300 305 Mmamum Power Voltage - Vsw.(V] 32.8 32.9 33.1 Maximum Power Current - I MPP(A) 8.9 9.0 9.1 Open Circuit Voltage - Voc (V1 39.7 39.8 40.0 TS4-L Open Circuit Voltage -Voc (V) •• 37.8 37.9 38.1 Short Circuit Current - Isc(A) 9.6 9.7 9.8 Module Efficiency 17.59% 17.89% 18.19% ** TS4-L is temperature independent m MADE Us CERTIFIED AMERICA CERTIFIED MADE IN WASHINGTON 0 CERTIFIED MADE IN MINNESOTA ARRA, BAA, and TAA SIH, Project C°TpTpnt 79.5 mm (3.13 MI_ 100mm 13.94 in] v 27 rrfrti.,; } . ' 1 (I.O6 in] 101.5 mm [4 in] TYP 203 mm [8 in] TYP [ MECHANICAL DATA Dimensions 1001 mm x 1675mm x 40mm Weight 43 lbs MAXIMUM RATINGS Operational Temperature -40...+90°C Maidmum System Voltage 1000 VDC Design Load (UL 1703) Up to 113 lbs/ft' Maximum Load (UL 1703) 113 lbs/ft' Maximum Wind Load 113 lbs/ft' Max Series Fuse Rating 15A Max Reverse Current 15A TEMPERATURE RATINGS Nominal Operating Cell Temperature (NOCT) 45.01°C Temperature Coefficient of Rap -0.39%/°C Temperature Coefficient of Voc -0.29%/°C Temperature Coefficient of Isc +0.04%/°C Temperature Coefficient of VMPP -0.38%/°C *Electrical characteristics may vary within ±2% of the indicated values at Standard Test Conditions (STC): Irradiance of 1,000W/m=. AM 1.5 spectrum, cell temperature at 25•C. For full electricol data on all wattages please see installation manual. Note: specifications subject to chance without notice. 9.5 mm 0 (.375 in] TYP 5 mm [.198 in] TYP 178 mm [7 in] 127,mm1 [5 in[- • _° `1I fir'#:., • 1067mm ^ i;ti• (42in] 13, .4 Imo, Junction Box a• Frome Depth: 40mm [1.57 in] 1001 mm [39.41 in] 947 mm [37. 8 in] 610 mm [24 in] 1219 mm [48 int 1675 mm [65.94 in] Manufacturing Facilities: 3886 Hammer Drive, Bellingham, WA 98226 1 2746 31st Avenue South, Minneapolis, MN 55406 Sales Offices: WA: (360) 647-9531 1 MN: (612) 318-6384 1 CA: (360) 393-0178. . infositekenergy.com 1 www.itekenergy.com V5.10.17 bluefrogsolar DIMENSIONS 90.1" (2290mm) • Single unit connects two solar modules • Maximum output power 500W • Individual MPPT for each module • Rated up to 310W • Up to 14 solar modules (7x YCS00s) in a string with a 20A breaker Our flagship product, the APsystems YC500A-MIW is a grid -tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. Highly dependable and cost effective, the YC500A handles up to 310W modules with negligible clipping, delivering 250W AC per module with dual MPPT. Half the inverters and half the installation means real cost savings for residential and commercial customers. EPL ANC �NFPA7o - NEC JUN 14 20 City of Tukwila BUILDING DIVISION.__ KWILA MAY 172017 bILief Mi R APsystems YC500A-MIW Microinverter Datasheet INPUT DATA (DC) Recommended PV Module Power Range (STC) MPPT Voltage Range Maximum Input Voltage Maximum Input Current 180-310W 22-45V 55V 12A X 2 OUTPUT DATA (AC) Rated Output Power 500W Maximum Output Current 2.08A @ 240V 2.4A @208V Nominal Output Voltage/Range - 240V 240V/211V-264V* Nominal Output Voltage/Range - 208V 208V/183V-229V* Nominal Output Frequency/Range 60Hz/ 59.3-60.5Hz* Power Factor >0.99 Total Harmonic Distortion <3% Maximum Units Per Branch 7 per 20A @ 240V 6 per 20A @ 208V EFFICIENCY Peak Efficiency 95.5% CEC Weighted Efficiency** 95% Nominal MPP Tracking Efficiency 99.5% MECHANICAL DATA Storage Temperature Range -40°F to +185°F (-40°C to +85°C) Operating Temperature Range (Ambient) -40°F to +149°F (-40°C to +65°C) Operating Temperature Range (Internal) -40°F to +185°F (-40°C to +85°C) Dimensions (WxHxD) inches 8.75" x 6.5" x1.1" Dimensions (WxHxD) mm 221mm x 167mm x 29mm Weight 5.5 lbs (2.5kg) Enclosure Rating NEMA 6 Cooling Natural Convection - No Fans FEATURES & COMPLIANCE Communication Power line (PLC) Warranty 25 years Emissions & Immunity (EMC) Compliance FCC PART 15, ANSI C63.4 2003, ICES -003 UL 1741 , CSA C22.2, No. 107.1-01, NEC2014 690.12 IEEE 1547 Safety Class Compliance Grid Connection Compliance Specifications subject to change without notice - please ensure you are using the most recent update found at www.APsystems.com 9.2776 © All Rights Reserved LTENERGY POWER * Programmable per customer and utility requirements. All settings UL approved **CEC registered as Altenergy Power System Inc. bluefrogso[ari 1015 Hostmark St., Ste 104, Poulsbo, WA 98370 1 206.855.5149 1 bluefrogsolar.com INSTALLERS;- please contact us to join our network of BlueFrogSolar registered installers D�� IRONRIDGE Flush Mount System Built for sotar's toughest roofs. RECEIVED CITY OF TUKWILA MAY 17 2011 PERMIT CENTER IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinfor is also why our products are fully certified, code compliant and backed by a 20 -year war - • t Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. Tl PE Certified JUN 14 2011 Pre -stamped e gineering letters available in most states. liAgEdVOR MPLIANCE WITH NFPA70-NEC Design Assis City of Tukwila ILDING DIVISION Online software makes it simple to create, share, and price projects. 20 -Year Warranty Twice the protection offered by competitors. XR Rails 1 XR10 Rail Datash9eet A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish Clamps & Grounding O UFOs Universal.Fastening Objects bond ,mocivites 1t0; rails. • Fully assembled & tubed • Single, universal size • Clear & black finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy Toad capability • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability Clear anodized finish Bonded Splices All rails use internal splices for seamless connections. Self -drilling screws • Varying versions for rails • Forms secure bonding Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L -Feet Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated Microinverter Kits Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled r -r .777 777 - Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design 45, ¢i gRDL� ((NABCEP NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge Inc. All nghts reserved. Visit www.ironndge.com or call 1-800-227-9523 for more information.���� d�� IRONRIDGE The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Flash Foot2 Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS -100 Wind -Driven Rain Test. RECEIVED CITY OF TUKWILA MAY 17 2017 PERMIT CENTER Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. iia ISI. N_ Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features Tech Brief 0' Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. QRounded Corners Makes it easier to handle and insert under the roof shingles. 0 Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and;decreases uplift capacity. 1200 11111-FlashFoot2 JD 1000 \ \ \ _ 1Z..-- \ p s, \ ,�, 800 \ \ 0 FlashFoot Leading Competitor Ca_ 600 \ \ L.) • \� w 400 -` \ 'V Low -Cost Competitor FlashFoot2 is the only product to align the 200 rail and lag bolt. This concentric loading design results in a stronger attachment for the system.. 1,,JF': ,.: 0 1 2 Rail -to -Lag Offset (in) 3 Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441, Section 27,"Rain;Test' and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Allow ��. IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC JUN 14 2017 RECEIVED CITY OF TUKWILA MAY 17 2017 PERMIT CENTER ����e��//n±±� MateAAials bU r - r ®geries aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. Tech BPief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design Toads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. • 6' spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8' spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12' spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load :Snow (PSI' zy None ft;10-201 . P1 i s � w .•_ 1 r 30 40 50-70 Wind MPH)" 100 120 140 160 100 X120 140 Rail Span 160 100 160 100 160 160 XR10 ars; 4" 4< 80-90 160 0 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.13 IRONRIDGE Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO Family of Components Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and Lubricated, and can fit a wide range of module heights. RECEIVED CITY OF TUKWILA AY 172011 PERMIT CENTER L Bonded Splice Each Bonded Splice uses self -drilling screws to form a secure connection. No bonding strap needed. �r - ✓, R ' � x. D .FOR COMPLI WITH NFPA70-NEC Groun A single connects of PV mo groundin ing �ugJUN 14 2017 ounding Lug n entire row ules to the conduce of Tukwila BUILDING DIVISION Bonded Attachments The bonding bolt attaches and bonds the L -foot to the rail. It is installed with the same socket as the rest of the system. Tech Bvief System Diagram O UFO Stopper Sleeve • Grounding Lug m Bonded Splice Ground Wire IT 4#A roved Enphase microinverters canprovide equipment roundin of IronRidge systems, eliminatingthe need for PPgrounding 9 Y � grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. Q Go to IronRidge.com/UFO Feature XR Rails Cross -System Flush Mount d Compatibility Tilt Mount d Ground Mount XR1000 Only UFO/Stopper d d d Bonded Splice v v N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire.Rating Class A. Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. 0 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Did IRONRIDGE Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating—the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Vagbaita Class A Fire Rating Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burning Brand Test A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 mire Spread of Flame Test CEIVED CITTOFTuKWIL MAY 17 2017 PERMIT CENTER Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. REVIEWED FOR 'Class A rated PV systems can be installed on Class A, B, and C roofs (;-.POEJ SIS 1 4 2017 , odule Rating* Tyse Flush Mount aAny 1, 2, & 3 Class A Tilt Mount A.>. P a 1, 2, & 3 Class A City ofTWO" �� G DIVISIONy ila s n 'Class A rated PV systems can be installed on Class A, B, and C roofs Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if 1 have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the, new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 150503Vw 3.s' k fir` Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC .refers,to a,Class C .fire rating. Class A or B is required for areas suchras Willlland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources Tech Brief What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class A fire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. Go to tronRidge.com Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. Go to IronRidge.com © 20161ronRidge, Inc. All rights reserved. Visit www.ironridge.com or; call 1-800-227-9523 for more information. Version 1.20 LAW= PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL 17-0371 PROJECT NAME: VOGEL RESIDENCE SITE ADDRESS: 15030 43 PL S X Original Plan Submittal Response to Correction Letter # DATE: 05/17/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C, (0-14-17 Building Division Public Works Fire Prevention Structural Planning Division n CPermit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/18/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/15/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: !Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 A&R Solar Horne Espaiiol Contact Safety & Health Claims & Insurance CIlik Washington State Department of JP Labor & Industries Search L&I Page 1 of 3 AR A -Z Index Help My L&:7.1 Workplace Rights Trades & Licensing A&R Solar Owner or tradesperson Principals CLIPPARD, WILLIAM R, PRESIDENT YATTEAU, ANDREW, VICE PRESIDENT CLIPPARD, WILLIAM R, AGENT Doing business as A&R Solar WA UBI No. 602 707 872 Parent company A AND R SOLAR CORP 24441st ave s SEATTLE, WA 98134 206-707-9937 KING County Business type Corporation Governing persons ANDREW YATTEAU DAVID KOZIN; EVAN MANDERBACH; WILLIAM CLIPPARD; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. RSOLAS*903JM Effective — expiration 05/20/2010— 05/20/2018 Designated administrator Clippard, William Active. Meets current requirements. Active. Meets current requirements. License type License no. Electrical Administrator CLIPPW*902JN Bond CBIC Bond account no. SI6249 $4,000.00 Received by L&I Effective date 05/20/2010 05/17/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 6/15/2017 1 A&R Solar Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 168,352-00 Doing business as A&R SOLAR Estimated workers reported Quarter 1 of Year 2017 "31 to 50 Workers" L&1 account contact Employer Services Help Line — 360-902-4817 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/26/2016 Inspection no, 317939903 Location 19 Main Street Soap Lake, WA 98851 Violations Inspection results date 01/27/2016 Inspection no. 317938661 Location 507 123 Ave NE Bellevue, WA 98006 Violations Inspection results date 12/03/2015 Inspection no. 317937464 Location N Barker Spokane Valley, WA 99216 Violations Inspection results date 08/14/2015 Inspection no. 317937085 Location 10567 NE W. Kingston RD Kingston, WA 98346 Violations Inspection results date 11/24/2014 Inspection no. 317607836 Location 12010 120th St. NE. Lake Stevens, WA 98258 Violations Page 2 of 3 C? Washington State Dept. of Labor & Industries. Use of this site is subject to the taws of the state of Washington, Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 6/15/2017