Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL17-0398 - WOODSPRING SUITES - COOKING PROVISIONS
WOODSPRING SUITES 15637 WEST VALLEY HWY ELI 7-0398 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0005800002 15637 WEST VALLEY HWY Project Name: WOODSPRING SUITES ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL17-0393 7/11/2017 1/7/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NELSEN FAMILY TRUST 10510 NORTHUP WY #300 C/O VWC, KIRKLAND, KS, 98033 LINDSEY KNOX Phone: (913) 236-3404 6700 ANTIOCH PLAZA - SUITE 300 , MERRIAM, KS, 66204 ACE ELECTRIC INC Phone: (509) 366-9723 1165 COLUMBIA PARK TRAIL, RICHLAND, WA, 99352 ACEELI*003CM Expiration Date: 8/11/2018 , DESCRIPTION OF WORK: EXTENDED STAY HOTEL THAT IS CONSIDERED A MULITI-FAMILY DWELLING, 4 STORIES, 118 ROOMS WITH PERMANENT COOKING PROVISIONS. ALL EQUIPMENT Valuation of single family: $0.00 Valuation of mf/comm: $576,502.00 Type of Work: NEW Fees Collected: $8,696.28 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature: 2014 2014 2014 2015 Date: 1 -If -17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 10624a!1 '!�/`"' "FQ7iY ] Date: 7/ ( (1 Print Name: 3/ei4v\fj6A W1llirq-L44.S' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWi Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. ti -1 l V 0.39 e Project No. Date Application Accepted: i -�- 1 7 Date Application Expires: -7 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 37 King Co Assessor's Tax No.: Site Address: 15644 W. Valley Hwy., Tukwila, WA 98188 Suite Number: Floor: Tenant Name: WoodSpring Suites Hotel New Tenant: ® Yes ❑..No PROPERTY OWNER Name: Lindsey Knox Name: Tukwila Hotel Holdings, LLC. City: Merriam State: KS Zip: 66204 Address: 10620 NE 9th Place Email: lindsey.knox@brrarch.com City: Bellevue State: WA Zip: 98004 CONTACT PERSON — person receiving all project communication Name: Lindsey Knox Address: 6700 Antioch Plaza, Suite 300 City: Merriam State: KS Zip: 66204 Phone: (913) 236-3404 Fax: Email: lindsey.knox@brrarch.com ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $Lj 7'1 . 7i Scope of Work (please provide detailed information): Extended stay hotel that is considered a multi -family dwelling. 4 -stories, 118 rooms with permanent cooking provisions, A1 EmAFI,u,6 . Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: • New 0 Addition 0 Service Change 0 Remodel 0 Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: ® Puget Sound Energy 0 Seattle City Light W:\Permit Center\Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm;°furnace thermostat) $61.05 ea f RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: lif,ck:PA.AyPeit) to ri7o Yr; W:\Permit Center\Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised I-I-17.docx Revised: January 2017 bh Day Telephone: City Date: t', 75 17 W7a 'ic1q IS -23 Vo 6 Cf State tp Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK; ACCOUNT QUANTITY PAID $69.87 EL17-0398 Address: 15637 WEST VALLEY HWY . Apn: 0005800002 $69.87 Credit Card Fee $2.04 Credit Card Fee R000.369.908.00.00 0.00 $2.04 ELECTRICAL $67.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R13794 R000.345.830.00.00 1.00 $67.83 $69.87 Date Paid: Wednesday, February 14, 2018 Paid By: RODOLFO GONZALEZ Pay Method: CREDIT CARD 051617 Printed: Wednesday, February 14, 2018 2:16 PM 1 of 1 CRISYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY PAID $16,173.06 ' EL17-0398 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $7,023.92 ELECTRICAL $6,689.45 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 0.00 $6,689.45 TECHNOLOGY FEE $334.47 TECHNOLOGY FEE 1 R000.322.900.04.00 I 0.00 $334.47 PG17-0072 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $9,149.14. GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 • PLUMBING $8,614.02 PERMIT FEE R000.322.100.00.00 0.00 $8,580.87 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $435.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11731 R000.322.900.04.00 0.00 $435.67 $16,173.06 Date Paid: Friday, June 16, 2017 Paid By: TUKWILA HOTEL HOLDINGS Pay Method: CHECK 1008 Printed: Friday, June 16, 2017 10:51 AM 1 of 1 CWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $4,546.68 ✓. EL17-0398 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $1,672.36 ELECTRICAL $1,672.36 PLAN CHECK FEE R000.345.832.00.00 I 0.00 $1,672.36 M17-0073 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $695.95 MECHANICAL $695.95 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 $695.95 PG17-0072 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $2,178.37 GAS $24.86 PLAN CHECK FEE 1 R000.322.103.00.00 0.00 $24.86 PLUMBING • $2,153.51 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11582 R000.322.103.00.00 0.00 $2,153.51 $4,546.68 Date Paid: Friday, May 26, 2017 Paid By: TUKWILA HOTEL HOLDINGS Pay Method: CHECK 1001 Printed: Friday, May 26, 2017 11:30 AM 1 of 1 CWYSTEMS /Z INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION D 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: 0 10a -1)5R-4 Type of Inspection: Address: i%31(Ai Date Called: Special Instructions. Date Wanted: a.m.' P.m. Requester: Phone No: u,' 5.6s3 7co Approved per applicable codes. E Corrections required prior to approval. OMMENTS: WI bap ritt-4> .,5o tt.►1 .- 43? Inspector: :j Date: cc -fig( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT NO. CITY OF TUKWILA BUILDING DIVISION .i 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspgction Request Line (206) 438-9350 Project: 0 02)1 Type of Inspection: ij Address: 1503.E Date Called: Special Instruction Date Wanted: [�U Cas. Requester: Phone No: i% 7/5..— 5...._ 70 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,-- - :j EPCL- to,Dr w646riziA0 i 4-v1 -- 6G ,took kc- INC (/c s1r4PPaLr i o r e'N b0.i 19 Inspector: '.-4\16/k Date: a5A7///g REINSPECTION EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit atifT0VPEIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspection: KApt-L kPri="60-7104 P1/4_&400064) ril Address: �%� rA t a 1 J Ko Ki . V '(moi Date Called: _ Fc- ,fs ounfi, IVz—AvAibki — 1 / Special Instruction: St— rima Date Wanted: 7/. 0. Requester: - LitSeL, ICAPJAce biSc-05 Phone No: ck.,if)> 0 Approved per applicable codes. corrections required prior to approval. COMMENTS: , eiCCA kPri="60-7104 P1/4_&400064) ril Q Kooll 1Ji rE -iN rL ®r 5/A"e _ Fc- ,fs ounfi, IVz—AvAibki — 1 / tk couPc,- ,9 urs t (�� 1/. — xci c.) 1 ` P WO /Jo P06V - LitSeL, ICAPJAce biSc-05 - 5FAIP4-__ 6u-A4k.p5 Fo 111-- 0 ck.,if)> Inspector: Date: in REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit tnspction Request Line (206) 438-9350 Project: 0 Type of Inspection: _ / Address:Date � 7 Called: Special Instruction:. Date Wanted: 5—b CaE;11:71-Le Requester: Phone No: ttAT 5� 7414V ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: woe\ Utkr5 A-0> cb.bob.. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: 60`_�2 l Type of Inspection: �� Address: . 513 (J. A� Date Called: .,00 Jac .- uto-S - P ) jr,u— kg)v f�',.,5,) Special Instructioris: e, ,_ iAefb Z �i GI��j '` Date Wanted: P / q lJ� a.m` p.m. Requester: / Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?A' -it,- — 6-6\i/AV\ btsca kit) ipcgiAle pimitst__ .,00 Jac .- uto-S - P ) jr,u— kg)v f�',.,5,) (DikecilQ Af5 C(PiekGrt ?i,rnl .SuNJL5 �; sy4JL j J1 r7 u�. -( — Wr ktoi Date: 61/210 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 E1 17- 291, Project: Type of Inspection: Address: IS C. 3-7 w urjel ike Date Called: Special Instructions: ./ 1' `� r'f�i Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. E Corrections required prior to approval. COMMENTS: Wein-oat FI° P 1- �s - o7t' HI7 Inspect Date: Li j t REIhtSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISIONiiie--, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: WOO" Sen^S C✓ite--,, Type of Inspection: L,5I" I Addr ss: 1 6 3-7 (.,> i)allc Date Called: Special Instructions: i, a ,_____—___, l-PW Date Wanted: a.m. p.m. Requester: Phone No: pproved per applicable codes. E Corrections required prior to approval. COMM6jdT5: L(c? kT' / e 1141 9) Limcg 62,l ,cer Inspect Date: /l c (J c REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit a'17 -x'57 PMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: <11 .f Type of Inspection: Address: (%'7 tJ47 Date Called: Special Instruction : Date Wanted:m. 0 Requester: Phone No: 20e 3io *4 Li ❑ Approved per applicable codes. []Corrections required prior to approval. COMMENTS: fA rck Fuotok Spornet-S ibr J,Jtrf o41 ttec-Pr AbA (dor Pu6A-I)i) Inspector: Date: O p1/ REINSPECTIO FEE REQUIRED. Prior to next inspection. fee mlust be paid at 6300 So thcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit o3?8 i -d INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-367 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 0&)9 a a of Inspectio 00114 i i Address: /513 j• 1.41t a e Called: Special Enstructio s: Date Wanted: f � 7 a p.m` Requester: Phone No: 2Y 3tro My ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 9 (A/ Ot FLAAA FLP0f\ es)a-iwk ti Inspector: Date: REINSPECTION IEEE REQUIRED. Prior to next inspection. fee Faust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 DODO Pi Address: /c63.7 3f J Special In tructi s: Project: Type of Inspection: rl�l/kFi Date Called: Date Wanted: & a Requester: Phone No: 261 Tfo ittly LJApproved per applicable codes. Corrections required prior to approval. COMMENTS: o Sti Inspector: Date: 2,11fEl REINSPECTION' FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspettion Request Line (206) 438-9350 Project: 02,/ 0 '1' IVAIA Type insp do Address: /5 ki - Date Called: Special Instructio s: Date Wanted: m. p.m. Requester: VzcPhone No: % \F 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ori 5604 Inspector: -1( 66/4K\ Date: � ) � I REINSPECTION IjEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspgction Request Line (206) 438-9350 Project: r�®�� ,hf\ti Type of Inspection:az d� GO Address: r��/ - 7 / r If Date Called: Special Instructions: Date Wanted: 77 a. - Y 2,-4' Requester: Phone No: / v ! 5-b� N4 y ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Th5 i' "I,tT G P19-- MIR PouieA, 41—t P tr I 5 (a &p Inspector: P 6/A161Z_ Date: �� /17 REINSPECTIONjFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Sou hcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit kill "oINSPECTION NO. PIT NO. CITY OF TUKWILA BUILDING DIVISION'. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 0OOP 5^� ktfl Type of Inspection: V Address: 1 7a-vm,,...7 Date Called: 0111( '_ s "ui LAI -km- fig rill Special Instructions: / Date Wanted: 4 p.m. Requester: 6 L-1)(/ Phone No: 0 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 0111( '_ s "ui LAI -km- fig rill Ft2-0 e1 AULT ri\Pd&i& hcJ CaaP1&Jr -- Li 5 kP 6-rL-' (Afro 6 L-1)(/ Inspector: Date: /24 -7 REINSPECTION,IFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PE IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: J Type of Inspection: V • Address: t ,r ate Called: Special Instructions: Date Wanted: Cg Qri Requester: Phone No: 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: P�- - y 41_sektilez zd-ro. / x I11 < ttt cArw V Inspector: EhiNitS Date: __i0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r INSPECTION RECORD ti _�� Retain a copy with permit INSPECTION NO. P MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspektion Request line (206) 438-9350 Project: k A �� � �fj Type of Inspection: / PVA Address: 1 i2 3 7 V/ ate Called: Special InstruGUons: y Date Wanted: 74f — p:m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: K (616"1‘)/er\ Date: 7/If REINSPECTIO FEE REQUIRED: rior to next inspection. fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: r7 12/1/2017 City of Tukwila Department of Community Development LINDSEY KNOX 6700 ANTIOCH PLAZA - SUITE 300 MERRIAM, KS 66204 RE: Permit No. EL17-0398 WOODSPRING SUITES 15637 WEST VALLEY HWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/22/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/22/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ley Permit Technician File No: EL 17-0398 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 brr Change Narrative Project Name: WoodSpring Suites Project Description: New Construction Project Number: 31000057 ARCHITECTURAL SHEET LS1.1 — BUILDING CODE AND LIFE SAFETY PLANS DETAIL 1— FIRST FLOOR LIFE SAFETY. PLAN 1. Revised wall of Elevator Machine Room. 2. Addition of 2 -hour rated wall. SHEET A1.1 — FIRST FLOOR PLAN DETAIL 1— FIRST FLOOR PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A1.6 — FIRST FLOOR RCP DETAIL 1— FIRST FLOOR RCP 1. Revised wall of Elevator Machine Room. SHEET A4.1 — ENLARGED PUBLIC PLANS DETAIL 1— FIRST FLOOR ENTRANCE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 - FIRST FLOOR FURNITIRE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A4.2 — ENLARGED FINISH PLANS DETAIL 1— FIRST FLOOR REFLECTED CEILING PLAN 1. Revised wall of Elevator. Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 - FIRST FLOOR FINISH PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. Project Location: Delta Number: Revision Date: www.brrarch,com Page 1 of 3 Tukwila, WA 9 — CCD#5 09/08/2017 REVISION NO, ---• RECEIVED CITY OF TUKWILA SEP 182017 PERMIT CENTER Du,o.1I, 6700 Antioch Plaza, Suite 300, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco -,Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 2 of 3 SHEET A6.2 — ELEVATOR PLANS, SECTIONS & DETAILS DETAIL 1— TYPICAL ELEVATOR TOWER SECTION 1. Revised room name to Elevator Machine Room. DETAIL 3 — FIRST FLOOR ELEVATOR PLAN 1. Addition of finish dimensions. 2. Revised room name to Elevator Machine Room. DETAIL 5 — UPPER FLOOR ELEVATOR PLAN 1. Removed elevator control panel note. SHEET A7.1 — PARTITIONS, FINSH SCHEDULE & DETAILS ROOM FINISH SCHEDULE 1. Revised room name to Elevator Machine Room. SHEET A8.1— DOOR SCHEDULE & DOOR DETAILS DOOR SCHEDULE 1. Revised room name to Elevator Machine Room. 2. Revised fire rating of Elevator Machine Room. MECHANICAL SHEET M-1— MECHANICAL NOTES, SCHEDULES, AND LEGENDS SCHEDULE — DUCTLESS SPLIT SYTSEM SCHEDULE 1. Added to plans SCHEDULE — EXHAUST FAN FAN SCHEDULE 1. Remove EF -5. SHEET M-2 — MECHANICAL FIRST FLOOR PLANS DETAIL 4 — MECHANICAL FIRST FLOOR PLAN 1. Update elevator machine room. 2. Add FCU -1 to elevator machine room. SHEET M-5 — MECHANICAL FOURTH FLOOR PLANS DETAIL 3 — MECHANICAL ROOF PLAN 1. Add CU -1. DETAIL 4 — ELEVATOR SHAFT RELIEF HOOD DETAIL 1. Revise control description. PLUMBING SHEET P-2 — PLUMBING WASTE AND VENT PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WASTE & VENT 1. Revised sump pump drain line and floor drain per elevator change. SHEET P-6 — PLUMBING WATER AND GAS PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WATER AND GAS PLAN 1. Added hose bib per owner directed RFI. SHEET P-10 — PLUMBING ENLARGED PLANS www.brrarch.com 6700 Antioch Plaza, Suite 30o, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 3 of 3 DETAIL 1—SUMP PUMP DETAIL 1. Revised sump pump drain line and floor drain per elevator change. ELECTRICAL SHEET E-1— ELECTRICAL RISER DIAGRAM PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-2 — ELECTRICAL PLANS — FIRST FLOOR PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-3 — ELECTRICAL PLANS — FIRST FLOOR DETAIL 1— FIRST FLOOR ELECTRICAL PLAN 1. Added callout for elevator control room. DETAIL 3 — ENLARGED LAUNDRY 1. Revised treadmill electrical circuit. DETAIL 4 — ENLARGED ELEVATOR 1. Added detail and keynotes. SHEET E-6 — ELECTRICAL PLANS — FOURTH FLOOR DETAIL 2 — ELEVATOR ELECTRICAL PLAN 1. Removed detail. DETAIL 3 — ELECTRICAL ROOF PLAN 1. Added CU -1. End of Revision/Addendum/Construction Change Directive By: BRR Architecture, Inc., Drew Truskey, Designer www.brrarch.com 6700 Antioch Plaza, Suite 300. Merriam. KS 66204 MAIN 913.262.9095 Kansas City - Bentonvitte - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago .44 4.44 roty t4. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0398 PROJECT NAME: WOODSPRING SUITES SITE ADDRESS: 15643 W VALLEY HWY Original Plan Submittal Response to Correction Letter # DATE: 09/20/17 Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Building Divi Public Works on Fire Prevention Structural Li Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable El (no approval/review required) DATE: 09/19/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 10/19/17 Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: 'Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 rERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0398 PROJECT NAME: WOODSRING SUITES SITE ADDRESS: 15637 WEST VALLEY HWY X Original Plan Submittal Revision # DATE:. 05/25/17 before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: sk, Aux- -» (7 Building Division • Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/30/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/27/17 E Notation: REVIEWER'S INITIALS: DATE: [Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PROJECT NAME: IN 11 (kit .,7 PERMIT NO: M " V C( SITE ADDRESS: 15(f IV) 1A1fa ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. REVISION DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INI �I S 9 1 V6 ri ,N -11-f-10 Summary of Revision: 411 404(/ r Received by: j Z -0 DOA ( IJ 1_,V1-1-A0,1---c- �V1-1-A0,1 S REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http;/ www.Tukwila\VA.cov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 09.18.17 Plan Check/Permit Number: v " O?P\ ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # X❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: WoodSpring Suites Project Address: 15643 W Valley Hwy Contact Person: Lindsey Knox Phone Number: 913.236.3404 Summary of Revision: The overall change was switching elevator types. The owner switched from a electric traction elevator to a machine room hydraulic elevator. It included adding a machine room adjacent to the elevator. Sheet Number(s): 18 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W. \Penmt Center\Templates\Forms\Revision Submittal Form. doc Revised August 2015 ACE ELECTRIC INC Home Espa iol Contact Safety & Health Claims & Insurance Washington State Department of ILI Labor & industries Search L&I Page 1 of 3 A -Z Index help My L&I Workplace Rights Trades & Licensing ACE ELECTRIC INC Owner or tradesperson Principals Gutzmer, Roger Gregory, PRESIDENT Gutzmer, Lora L, VICE PRESIDENT GUTZMER, ROGER GREGORY, AGENT Doing business as ACE ELECTRIC INC WA UBI No. 601 985 206 1165 COLUMBIA PARK TRAIL RICHLAND, WA 99352 509.366-9723 BENTON County Business type Corporation Governing persons LEO R GUTZMER ROGER GREGORY GUTZMER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............_................................................. Meets current requirements. License specialties GENERAL License no. ACEELI*003CM Effective — expiration 02/14/2000— 08/11/2018 Designated administrator GUTZMER, ROGER GREGORY Active. Meets current requirements. License type License no. Electrical Administrator GUTZMRG092RG Bond ................ Wesco Insurance Co Bond account no. 46-WB079867 $4,000.00 Received by L&I Effective date 09/19/2016 09/21/2016 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations ................._.................................... Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601985206&LIC=ACEELI*003 CM&SAW= 7/11/2017 EXTERIOR PROVIDE CT CABINET AND METERING PER UTILITY CO. STANDARDS. VERIFY ALL REQUIRMENTS PRIOR TO BID. INTERIOR 4TH FLOOR 3RD FLOOR 2ND FLOOR 1ST FLOOR MDP DP1 G 433 MDP -3 MDP -6 DP1-1 G 432 G 431 G 430 G 429 123 > < 123 > < 123 > < 123 G 332 G 331 G 330 G 329 123 > < 123 > < 123 > < 123 G 232 G 231 G 230 G 229 123 > < 123 > < 123 > < 123 G 132 123 DP1-2 G 131 123 DP1-3 G 130 123 DP1-4 G 129 123 DP1-5 DP1-6 DP1-7 DP1-8 DP1-9 G 424 123 G 324 123 G 224 123 G 124 <1zI>> I 1 I I 1 1 1 1 1 DP1-11 G 422 G 421 G 420 G 419 DP2 123 > < 123 > < 123 > < 123 > < 804 G 322 G 321 < 123 > < 123 > G 222 G 221 G 320 G 319 123 > < 123 G 220 G 219 123 > < 123 > < 123 > < 123 G 122 G 121 G 120 G 119 123 > < 123 > < 123 > < 123 DP1-10 DP1-12 DPI -13 DP1-14 DP1-15 T MDP -2 C DP2-1 DP2-2 1 1 123 > < 123 G 418 G 417 123 > < 123 > G 318 G 317 <104> 123 > < 123 B-37,39,41 MDP -4 G 218 G 217 123 > < 123 G 118 G 117 DP2-3 DP2-4 DP2-5 DP2-6 DP2-7 DP2-8 DP2-9 DP2-10 DP2-11 DP2-12 DP2-13 DP2-14 DP2-15 123 G 404 123 > < 123 > < 123 > < 123 > ® < 123 123 > < 123 > < 123 > < 123 TO ELEVATOR POWER MODULE. REFER TO SHEET E4 FOR MORE INFORMATION. - 1604 }- TO PAD MOUNTED UTILITY TRANSFORMER -< 804 1 I, PANELBOARD DPI BUS AMPS: 800A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 53,028A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 PANELBOARD G (3 UNITS) 125 2 RD 26,190 61,110 (1) 2-1/2"C 34,920 RD 2 125 PANELBOARD G (4 UNITS) 2 24,352 18,264 - 42,616 1604 > (4) 4"C (4) #600kcmil 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 4 3 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 100% = 24,352 24,352 26,190 RD 2 125 PANELBOARD G (3 UNITS) 6 5 PANELBOARD G (4 UNITS) 125 2 RD 34,920 35,600 61,110 100% = 35,600 42,616 18,264 24,352 52,380 = 15,000 26,190 RD 2 125 PANELBOARD G (3 UNITS) 8 7 PANELBOARD G (3 UNITS) 125 2 RD 26,190 18,264 18,264 DP2 DEMAND = 36,528 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 281,005 SUB-TOTAL(VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 61,110 34,920 RD 2 125 PANELBOARD G (4 UNITS) 10 9 PANELBOARD G (3 UNITS) 125 2 RD 26;190- 42,616 24,352 18,264 34,920 RD 2 125 PANELBOARD G (4 UNITS) 12 11 PANELBOARD G (3 UNITS) 125 2 RD 26,190 61,110 42,616 24,352 18,264 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 14 13 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 48,704 34,920 0 2 125 SPARE 16 15 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 0 24,352 0 2 125 SPARE 18 17 SPARE 125 2 0 0 0 0 0 0 0 2 125 SPARE 20 19 SPARE 125 2 0 0 0 0 PER PHASE SUB -TOTALS 299,002 250,068 251,102 -- -LEGEND: TOTAL CONNECTED PANELBOARD (VA) 800,172 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 2,221 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 143,153 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 397 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM PANELBOARD DP2 BUS AMPS: 800A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 22,157A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 PANELBOARD G (4 UNITS) 125 2 RD 34,920 69,840 (1) 2-1/2"C 34,920 RD 2 125 PANELBOARD G (4 UNITS) 2 24,352 24,352 - 48,704 1604 > (4) 4"C (4) #600kcmil 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 4 3 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 100% = 24,352 24,352 34,920 RD 2 125 PANELBOARD G (4 UNITS) 6 5 PANELBOARD G (4 UNITS) 125 2 RD 34,920 35,600 69,840 100% = 35,600 48,704 24,352 24,352 69,840 = 15,000 34,920 RD 2 125 PANELBOARD G (4 UNITS) 8 7 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 DP2 DEMAND = 48,704 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 281,005 SUB-TOTAL(VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 10 9 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 24,352 24,352 34,920 RD 2 125 PANELBOARD G (4 UNITS) 12 11 PANELBOARD G (4 UNITS) 125 2 RD 34,920 69,840 48,704 24,352 24,352 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 14 13 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 48,704 34,920 0 2 125 SPARE 16 15 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 0 24,352 0 2 125 SPARE 18 17 SPARE 125 2 0 0 0 0 0 0 0 2 125 SPARE 20 19 SPARE 125 2 0 0 0 0 PER PHASE SUB -TOTALS _ 331,280 285,792 272,008 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 889,080 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 2,468 GF - GROUND FAULT INTERRUPTER LC( - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 150,028 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 416 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM 204 FEEDER SCHEDULE FEEDER TAG (QUANTITY) CONDUIT SIZE (QUANTITY) CONDUCTOR SIZE GROUND';. SIZE ISOLATED GROUND SIZE EACH CONDUIT (1) 1-1/4"C (4) #3 #8G - 104 > 125% 123 > (1) 1-1/2"C (3) #1 #6G - 125% 204 > (1) 2"C (4) #310 #6G - 125% 224 > (1) 2-1/2"C (4) #410 #4G - 0 804 > (2) 4"C (4) #500kcmil #1/OG - 100% 1604 > (4) 4"C (4) #600kcmil NOTE 1 - 100%;50% NOTE 1: PER ARTICLE 250.92 CONTRACTOR SHALL INSTALL #3/0 BONDING CONDUCTOR FROM EACH SERVICE ENTRANCE CONDUIT TO NEUTRAL BUS IN 'MDP' PROVIDE ALL BONDING OF EQUIPMENT AS REQUIRED. COMMERCIAL LOAD SUMMARY BUILDING AREA: 48,558 SQ. FT VOLTAGE: 208Y/120V, 3PH, 4W LOAD DESCRIPTION CONNECTED LOAD (VA) CIRCUIT DESCRIPTION DEMAND FACTOR WIRE SIZE DEMAND LOAD (VA) LIGHTING POWER & HVAC INTERIOR LIGHTING 6,379 x 125% = 0 EXTERIOR LIGHTING 10,189 x 125% = 12,736 SIGNAGE 13,800 x 125% = 17,250 MINIMUM GENERAL LIGHTING PER NEC -220 x 125% 21,821 MINIMUM TRACK LIGHTING/SHOW WINDOW PER NEC -220 x 125% 0 2 250,068 EXISTING 0 x 100% = 0 RECEPTACLES 14,970 x 100%;50% = 12,485 MISCELLANEOUS EQUIPMENT 128,746 x 100% = 128,746 REFRIGERATION EQUIPMENT 0 x 100% = 0 KITCHEN 0 x 100% = 0 HVAC - SUMMER 0 x 100% = 0 HVAC - WINTER 35,600 x 100% = 35,600 SUPP. ELECTRIC HEAT 15,000 x 100% = 15,000 MOTORS 13,121 x 100% = 13,121 LARGEST MOTOR 43,200 x 25% = 10,800 DP1 DEMAND = 143,153 DP2 DEMAND = 150,028 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 281,005 SUB-TOTAL(VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 560,739 780 1,556 1,600 44 ELECTRICAL RISER DIAGRAM SCALE: NOT TO SCALE SEPARATE PERMIT F SQUIRED FOR: "achanical I� Electrical (umbing as Piping City of Tukwila DIVISION REVISIONS �� No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NCT1 t cv sions will require a new plan submittal j and may include additional plan review fees. G 106 COPYI G 105 G 104 Permit11i©.._,.l-4 7 Q o Plan review approval is subject to err ors Approval of construction d and miss! �. the violation of �� ; """ ` not authorize of approved Field adc�ted code or ordinance. Receipt � and conditions Isacknowledged: Date GENERAL NOTES City of Tukwila 1. IF REQUIRED BY LOCAL CODE, ELECTRICAL CONTRACTOR SHALL PROVIE161 PANEL MDP AND REMOTE EXTERIOR LOCAKBLE BUILDING POWER OFF DEVICE TO ACTIVATE .. H 1NT TRIPS TO KILL ALL POWER TO BUILDING. IF UTILITY COMPANY AVAILABLE FAULT CURRENT EXCEEDS 65K AIC, PROVIDE CURRENT LIMITERS ON EACH SERVICE ENTRANCE CONDUCTOR. VERIFY ALL REQUIREMENTS WITH THE LOCAL AUTHORITY HAVING JURISDICTION PRIOR TO BID. 2. CONTRACTOR SHALL VERIFY WITH THE OWNER IF LIGHTNING PROTECTION IS REQUIRED ON THE PROJECT. LIGHTNING PROTECTION SHALL BE INCLUDED IN BID WHEN REQUIRED. 3. ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT SHALL BE MOUNTED ON 6" HIGH CONCRETE HOUSEKEEPING PAD. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT GEAR PROVIDED FOR PROJECT FITS IN THE SPACE PROVIDED. 5. ALL WIRING IS TO BE COPPER. 6. AVAILABLE FAULT CURRENT AT UTILITY IS ASSUMED TO BE 66,094A. VERIFY WITH UTILITY CO. AND NOTIFY ENGINNER IF THERE ARE ANY DISCREPANCIES. INTERSYSTEM BONDING TERMINAL BAR. WALL MOUNTED ADJACENT TO MDP. #6 CU -3/4" C. TO TELEPHONE TERMINAL BOARDS. SEPARATE GROUNDING ELECTRODE REQUIRED FROM EACH TELE. BOARD. COLUMN #6 CU CONDUCTOR - CONCRETE ENCASED ELECTRODE PER ARTICLE 250.52.A.3 OF THE NEC. 7 -r -T CADWELL CONNECTION TO COLUMN ELECTRODE AND GROUND ROD. PANELBOARD MDP BUS AMPS: 1600A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 / SE RATED ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 58,889A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A FULLY RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P (VA) A B C P AMPS 1 PANELBOARD DP1 800 3 RD 299,002 630,282 331,280 RD 3 800 PANELBOARD DP2 2 250,068 535,860 285,792 251,102 523,110 272,008 3 PANELBOARD A 225 3 RD ,..e 17,812 45,138 27,326 RD 3 225 PANELBOARD D 4 18,567 41,672 23,105 45,728 26,314 5 ELEVATOR 3 RD 15,184 41,972 26,788 RD 3 225 PANELBOARD B 6 . 15,184 40,922 25,738 15,184 i 43,153 _ 27,969 PER PHASE SUB -TOTALS 717,392 618,454 611,991 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 1,947,837 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 5,407 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 555,583 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 1,542 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM PANEL TO HAVE BUILT-IN SPD WITH 240 KA SURGE RATING. BONDED NEUTRAL BUS WATER PIPE GROUND LOCATED ON HOUSE SIDE OF MAIN VALVE AT POINT SERVICE ENTERS THE BUILDING. MAIN WATER AND GAS SERVICE MAIN BONDING JUMPER. FURNISHED W/ SWITCHBOARD. MAIN PANEL OR DISC. DEVICE 6" HIGH CONCRETE BASE BONDING JUMBERS TO BUILDING STEEL AND WATER SERVICE. #3/0-3/4" C. PROVIDE JUMPER OVER ISOLATION CONNECTION. GROUNDING ELECTRODE CONDUCTOR 3/4" X 10' COPPERCLAD DRIVEN GP ROD IN ROOM. PROVIDE NUMBER REQUIRED FOR A MAXIMUM 25 O. ' RESISTANCE TO GROUND. - 2 SYSTEM GROUNDING DETAIL SCALE: NOT TO SCALE REPLACE WITH FOR COMPLIANCE PA 70 m NEC OCT 0 4 2017 fig,, W City of Tukwila BUILDING DIVISION �...�..�• RECEIVED CITY OF TUKWILA SEP 1.02017 PERMIT CENTER 1310NN01r B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P9133225150 4. F9133225155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL RISER DIAGRAM Sheet No. E-1 0 BRR Original printed on recycled paper 9/7/2017 4:35:52 PM GF GF EM GF FA EM PANELBOARD A BUS AMPS: 225A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 49,449A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 STAFF WASHER 20 3 8 1,733 3,557 3,339 1,824 8 1 20 EXTERIOR LIGHTING SITE 2 1,920 6 1 20 BUILDING SIGNAGE 4 1,733 FIRST FLOOR PTAC-2 3,653 2 3 1,750 12 3,653 1,920 4 1 20 BUILDING SIGNAGE 6 1,733 5 1,680 20 1 180 12 1 20 RECEPTACLES 8 7 EUH-2 20 2 8 1,500 744 12 1 20 WATER HEATER 10 1,500 1,500 2,244 2,950 9 12 1 2,477 744 12 1 20 WATER HEATER 12 11 STAFF WASHER 20 3 8 1,733 2,477 1 20 744 12 1 20 WATER HEATER 14 1,733 13 1,824 6 1 20 EXTERIOR LIGHTING SITE 16 1,733 20 3,557 16 15 FIRST FLOOR RCPT 20 2,540 1,750 6 2 20 FIRST FLOOR PTAC-2 18 17 STAFF DRYER 15 2 8 790 20 2,540 17 ROUTER 1,750 790 19 1,750 12 2 20 SECOND FLOOR PTAC-2 22 21 PYLON SIGN 20 1 6 1,200 20 2,950 12 24 01. 12 2,950 1,750 23 PYLON SIGN 20 1 6 1,200 1,990 1,000 TREADMILL 790 8 2 15 STAFF DRYER 26 25 PYLON SIGN 20 1 6 1,200 28 790 27 BOOSTER PUMP (IF REQUIRED) 20 3 12 1,272 2,600 2,062 25 VENDING 20 2,472 1,200 8 1 20 EXTERIOR LIGHTING 30 1,272 29 3,096 FACP 20 1,824 6 1 20 EXTERIOR LIGHTING SITE 32 1,272 31 1,500 10 2 20 EUH-4 34 33 BOOSTER PUMP (IF REQUIRED) 20 3 12 1,272 1,000 2,772 1,700 36 2,772 1,500 1,272 35 2,472 12 1,200 6 1 20 PYLON SIGN 38 1,272 37 1,200 6 1 20 PYLON SIGN 40 39 EXTERIOR LIGHTING 20 1 8 129 1,329 2,550 1,200 6 1 20 . PYLON SIGN 42 41 EXTERIOR LIGHTING 20 1 8 1,350 PER PHASE SUB -TOTALS 17,812 18,567 19,414 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 55,793 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 155 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 60,591 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 168 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM C - ROUTE VIA CONTACTOR PANELBOARD B BUS AMPS: 225A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 45,110A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 RECEPTACLES 20 1 12 1,080 2,160 3,339 1,080 12 1 20 SECOND FLOOR RCPT 2 1,750 6 2 20 SECOND FLOOR PTAC-2 4 3 FIRST FLOOR PTAC-2 20 2 12 1,750 12 3,500 2,877 8 2 35 FCU -2 6 6 2,600 5,477 3,500 1,750 1,750 5 2,950 20 1 1,450 12 2 20 ELECTRIC ROOM PTAC-3 8 7 VENDING 20 1 8 1,500 10 1,450 9 VENDING 20 1 8 1,500 10 2,950 908 12 1 1,239 879 12 1 20 LIGHTS & EM LIGHTS 12 11 RECEPTACLES 20 1 12 360 1,770 1 20 500 12 1 20 FRONT DOOR MAG -LOCK SYSTEM 14 13 LIGHTS & EM LIGHTS 20 1 12 1,270 180 12 1 20 ELEVATOR PIT 16 15 FIRST FLOOR RCPT 20 1 12 1,620 XB 1,800 2,420 1,880 17 2,300 1,800 10 1 20 ELEVATOR CAB 18 17 ROUTER 20 1 12 500 2,170 19 ELIPTICAL 1,170 10 1 20 SUMP PUMP 20 19 CATV 20 1 12 1,000 01. 12 1 20 DTB 22 21 ITB 20 1 12 1,000 TREADMILL 2,000 1 12 500 2,500 1,500 6 2 20 EUH-5 24 23 TTB 20 1 12 1,000 26 1,500 3,000 2,600 'Ir e; i BA,' r 25 VENDING 20 1 8 1,500 204 12 1 20 RCP -1 28 27 FACP 20 1 12 1,000 12,854 12,580 1,204 ... • 11,538 2,500 1,500 12 2 20 EUH-3 30 29 WIRELESS ACCESS POINTS 20 1 12 1,000 32 1,700 1,500 31 TIME CLOCK 20 1 12 200 180 12 1 20 TWO-WAY COMM. STATION 34 33 UTILITY ROOM 240 PTAC-1 15 2 12 1,250 1,430 2,750 re 1lamia ""e"-.- 1,250 35 48-,,, 13,038 37 PANELBOARD'C' 100 3 RD 11,538 ti q .,-\ �. �� . ,2. ,Pgi1F,..yr> S§ ti, :9y..- 12,854 12,854 39 13,180 :bG``"" id `10`'"k- Aft51 EkrER 41 12,580 41 PER PHASE SUB -TOTALS 26,788 25,738 27,969 -1.tGEl•1I: TOTAL CONNECTED PANELBOARD (VA) 80,495 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 223 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 79,187 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 220 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM PANEL TO HAVE BUILT-IN SPD WITH 120 KA SURGE RATING. PANELBOARD C BUS AMPS: 100A LOCATION: UTILITY ROOM 340 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 5,493A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 10,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 FOURTH FLOOR RCPT 20 1 12 1,080 2,340 3,339 1,260 12 1 20 THIRD FLOOR RCPT 2 1,750 8 2 20 THIRD FLOOR PTAC-2 4 3 FOURTH FLOOR PTAC-2 20 2 8 1,750 12 3,500 2,877 8 2 35 FCU -2 6 6 2,600 5,477 3,500 1,750 1,750 5 3,500 20 1 1,750 8 2 20 THIRD FLOOR PTAC-2 8 7 FOURTH FLOOR PTAC-2 20 2 8 1,750 10 1,750 1,750 3,241 12 3,500 GUEST DRYER 9 2 10 1,802 908 12 1 20 THIRD FLOOR LIGHTS, EM LTG, & EF -6 12 11 FOURTH FLOOR LIGHTS, EM LTG, & EF -2 20 1 12 894 720 2 10 360 12 1 20 THIRD FLOOR UTILITY RCPT 14 13 FOURTH FLOOR UTILITY RCPT 20 1 12 360 1,880 8 2 35 HP -1 16 15 WIRELESS ACCESS POINTS 20 1 12 1,000 WHITE 2,880 600 12 1 20 REGISTRATION RCPT 24 18 XB JUNO 2,420 1,880 17 FITNESS RCPT 20 1 12 540 1,722 3,776 TS - VIA TIME SWITCH ST - SHUNT TRIP 1,222 12 2 20 HP -2 20 19 ELIPTICAL 20 1 12 500 22 1,222 21 SPARE 20 1 33 0 20 1,222 12 1,176 3,006 2,506 8 2 50 HP -3 24 23 TREADMILL 20 1 12 500 37 3,256 4,184 1 25 FITNESS TELEVISION 20 1 12 750 1,352 12 2 15 FCU-1/CU-1 28 2,600 'Ir e; i BA,' r - 0 1 20 SPARE 42 PER PHASE SUB -TOTALS 'r0 LEGEND: 1,752 76,745 30 9 1,852 1,352 29 TREADMILL 20 1 12 500 - • ' • - 12,854 12,580 1 •: ... • 11,538 TOTAL CONNECTED PANELBOARD (VA) 36,972 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 103 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 35,152 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 98 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM C C C C C AF AF EM PANELBOARD D BUS AMPS: 225A LOCATION: GUEST LAUNERY 142 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 9,875A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 10,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # A B C AMPS P P AMPS 1 GUEST WASHER 20 1 12 1,176 4,136 3,339 2,960 8 2 40 FCU -1 2 3 GUEST WASHER 20 1 12 1,176 2 4,136 TOILET RECEPTACLE 2,960 4 5 GUEST DRYER 30 2 10 2,600 1,200 12 5,477 2,877 8 2 35 FCU -2 6 7 2,600 5,477 KITCHEN 20 2,877 • 8 9 GUEST WASHER 20 1 12 1,176 12 4,417 20 3,241 8 2 40 FCU -3 10 11 GUEST WASHER 20 1 12 1,176 1,250 - 4,417 3,241 12 13 GUEST DRYER 30 2 10 2,600 4,049 1,250 2,450 1,449 12 1 20 GUEST LAUNDRY/LOBBY LIGHTS 14 15 2,600 10 3,860 PTAC - LIVING ROOM 1,260 12 1 20 GUEST LAUNDRY RCPT 16 17 GUEST DRYER 30 2 10 2,600 1,080 12 3,320 9r wet19 LIVING ROOM RCPTS 2,600 2,600 1,250 1,994 0 1 20 SPARE 20 21 GUEST DRYER 30 2 10 2,600 14 2,960 SPACE ONLY 30'0 -.'''H'2./'&'''1/41-\ -''''- '''X "`-F"ECISi`ireti110"Nlt2'"L'' 23 2,600 0 WHITE 3,200 600 12 1 20 REGISTRATION RCPT 24 4,100 XB JUNO 25 GUEST DRYER 30 2 10 2,600 1,500 12 1 20 STAFF MICROWAVE 26 2,600 TOTAL CONNECTED PANELBOARD (VA) 3,776 TS - VIA TIME SWITCH ST - SHUNT TRIP 27 1,176 12 1 20 GUEST WASHER 28 29 GUEST DRYER 30 2 10 2,600 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM * - PHASES VARY DEPENDING ON FEEDER FROM PANELBOARDS'DP1' AND 'DP2'. AF - COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTER 4,100 1,500 12 1 20 STAFF REFRIGERATOR 30 31 2,600 2,780 180 12 1 20 GUEST LAUNDRY RCPT 32 33 GUEST WASHER 20 1 12 1,176 1,356 180 12 1 20 HEAT TRACE 34 35 GUEST DRYER 30 2 10 2,600 3,200 -,,,.,i40.„--).,.12, ).,.,% d�/(JT(JIII7 t„D 11A, k2S,-\. �• ,,,,,,,.r,N,,,3,5b 37 2,600 4,184 1,584 12 1 20 COFFEE MAKER 38 39 GUEST DRYER 30 2 10 2,600 2,600 i' '''0 °" ` i` 0° 4pARA,,,,,....--A"."49( 41 2,600 2,600 0 1 20 SPARE 42 PER PHASE SUB -TOTALS 27,326 23,105 26,314 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 76,745 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 213 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 77,073 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 214 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM GFEP - GROUND FAULT EQUIPMENT PROTECTION PANELBOARD G2 (TYPICAL OF 4 REQUIRED) MIN. SIZE LOAD CENTER CONSTRUCTIONRQ'D BUS AMPS: 125A LOCATION: ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 !SOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 1PH, 3W AFC VALUE: 7,207A FEED THRU LUGS: YES MOUNTING: RECESSED AIC RATING: 10,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P * LED/900/LD/830/830/FL120 _ P AMPS 1 LIGHTING AND BEDROOM RCPT 20 1 12 1,539 3,339 4 LED - 10W 1,800 12 1 20 REFRIGERATOR 2 3 TOILET RECEPTACLE 20 1 12 1,694 tf .,- ."1 FlitE' 2,894 1,200 12 1 20 MICROWAVE 4 5 KITCHEN 20 1 12 1,500 3,000 E JUNO 1,500 12 1 20 KITCHEN 6 7 PTAC - BEDROOM 15 2 12 1,250 - LED W/UNIT 2,450 1,200 12 2 20 RANGE 8 9 1,250 2,450 LED W/UNIT 120 1,200 10 11 PTAC - LIVING ROOM 15 2 12 1,250 - LED W/UNIT 2,330 1,080 12 1 20 LIVING ROOM RCPTS 12 13 1,250 1,994 TBD 120 744 12 1 20 DISHWASHER 14 15 SPACE ONLY - LED W/UNIT 120 0 WHITE CEILING/VARIES 0 0 XB JUNO NXPC-3-R-WH SPACE ONLY 16 PER PHASE SUB -TOTALS 10,783 WHITE 7,674 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 18,457 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 89 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 18,487 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 89 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM * - PHASES VARY DEPENDING ON FEEDER FROM PANELBOARDS'DP1' AND 'DP2'. AF - COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTER EM SYMBOL LEGEND LIGHT FIXTURE SCHEDULE FIXTURE TAG MANUFACTURER MODEL NUMBER. LAMP VOLTAGE TOTAL VA FINISH MOUNTING REMARKS NO. TYPE SURF./RECESSED A SYLVANIA LED/900/LD/830/830/FL120 - LED W/UNIT 120 13 WHITE SURFACE/CEILING CORRIDOR FIXTURE B STARTEX STX-BV2-4 4 LED - 10W 120 40 NICKEL SURFACE VANITY LIGHT -� �s -e----- L-rEt4§'Attia R GtIli . ` `' 7 3.3511 ,... 5-'• , `fr` 3'At' 1t0 tf .,- ."1 FlitE' '04WA'dtritftli.`lad-/AiltfifralcilIF'�` 4'-0" TO TOP S S2 S3 S4 SP SK D TEXES FLUORESCENT CERG213E120 2 13W 4 PIN 120 26 WHITE SURFACE/CEILING UTILITY LIGHT ELEVATOR PIT 4'-0" TO TOP E JUNO N1WH 2 5'4W INCLUDED 120 11 WHITE 7'-6" AFF EMERGENCY LIGHT STARTER (SIZE, POLE, VOLTAGE) • F RAB LIGHTING WPLED104 - LED W/UNIT 120 150 BRONZE SURFACE/CEILING WALL FLOOR/SEE ARCH. DRAWINGS FOR LOCATION CONDUIT RUN 2 CIRCUIT,3#12&1#12 GROUND -1/2"C. G BRUCK LIGHTING 103-040-AL/WH - LED W/UNIT 120 9 WHITE 7'-0" AFF CORRIDOR WALL SCONCE EARTH/FLOOR L HUBBELL LNC-7LU-5K4-1 - LED W/UNIT 120 16.4 BRONZE 8'-0" AFF EXTERIOR WALL PACK SPACE ONLY M TBD TBD- * - PROVIDE WITH POWERPACK AND FACTORY SETUP AT SITE. WIRE TO CONTROL LIGHTS IN AREA. TBD 120 50W TBD PENDANT DECORATIVE FIXTURE 0 XA JUNO NXPB-3-R-WH - LED W/UNIT 120 3 WHITE CEILING/VARIES EXIT LIGHT 0 XB JUNO NXPC-3-R-WH - LED/5.4W 120 14 WHITE 7'-6" AFF EXIT/EMERGENCY LIGHT COMBO 8,730 XC HUBBELL PG -Z 2 LED W/UNIT 120 3 BRONZE 7'-6" AFF EXTERIOR EMERGENCY LIGHT NOTES: 1. VERIFY IF BATTERY HEATER IS REQUIRED. 2. GENERAL CONTRACTOR SHALL PROVIDE FIREPROOFING AROUND RECESSED FIXTURES INSTALLED IN FARE RATED CEILING PER U.L. REQUIREMENTS. 3. SEE SPECIFICATIONS FOR LAMP AND BALLAST TYPE. VERIFY LAMP COLOR WITH ARCHITECT PRIOR TO ORDERING. 4. PROVIDE ARROWS AND FACES AS INDICATED IN THE DRAWINGS. 5. NO SUBSTITUIONS OF VENDORS OR PRODUCTS ON LIGHT FIXTURES UNLESS APPROVED BY WOODSPRING SUITES, THE ARCHITECT, AND OWNER. 6. PROVIDE ONE EXIT SIGN UP HIGH AND ONE DOWN LOW PER LOCAL AND NATIONAL CODES. PROVIDE INTERCONNECTION BETWEEN UNITS AS REQUIRED. TOTAL PANELBOARD DEMAND (AMPS) SYMBOL LEGEND SYMBOL DESCRIPTION MOUNTING FLUORESCENT FIXTURE & FIXTURE LETTER CEILING (A) CONNECTED PER PHASE (VA) FLUORESCENT FIXTURE & FIXTURE LETTER CEILING OA CIRCUIT DESCRIPTION LED FIXTURE & FIXTURE LETTER SURF./RECESSED OA 0 Q LED FIXTURE & FIXTURE LETTER WALL BRACKET ® EXIT FIXTURE - SHADING DENOTES FACE(S) CEILING/WALL 9 GFCI GFCI DUPLEX GROUNDED RECEPTACLE 1'-3" A.F.F. 9 DUPLEX GROUNDED RECEPTACLE 1'-3" A.F.F. 0 DOUBLE DUPLEX RECEPTACLE 1'-3" A.F.F. 9 WP/GFCI EXTERIOR GFCI RECEPTACLE WEATHERPROOF 1'-3" A.F.F. 0 SPECIAL OUTLET. SEE SCHEDULE OR AS NOTED 3 TV CATV OUTLET 1'-3" A.F.F. V 'V PHONE/DATA OUTLET (W=44" A.F.F.) 1'-3" A.F.F. M WATT STOPPER DW -100 MASTER LIGHT SWITCH 4'-0" TO TOP S S2 S3 S4 SP SK SWITCHES (1, 2 -POLE, 3 -WAY, 4 -WAY, PILOT, KEY) 4'-0" TO TOP SOS OCC. SWITCH, WATTSTOPPER #PW -100-W 4'-0" TO TOP T WATT STOPPER CS -50 LIGHT/TIME DELAY FAN SW. 4'-0" TO TOP 0 THERMOSTAT (BY MECH. CONTRACTOR) 4'-0" TO TOP 0 * MOTION SENSOR, WATTSTOPPER W -1000A 4'-0" TO TOP J JUNCTION BOX 20 =' 0/3/240 H.D. SAFETY SWITCH (AMPS, POLE, VOLTAGE) 6'-6" TO TOP ® 0/3/240 STARTER (SIZE, POLE, VOLTAGE) • 6'-6" TO TOP 1 I BRANCH CIRCUIT PANEL & PANEL DESIGNATION 6'-6" TO TOP PNLBD 'X' 2,450 CONDUIT RUN 2#12 & 1#12 GROUND - 1/2"C. CEILING/WALL 2 4k------. CONDUIT RUN 2 CIRCUIT,3#12&1#12 GROUND -1/2"C. EARTH/FLOOR 9 PARTIAL HOMERUN (MULTIPLE LOAD LOCATIONS) 2,450 \ #104----3 SEE GENERAL NOTE #7 10 .,--"�� CONDUIT RUN W/2 HOTS, 1 NEUTRAL, & 1 GROUND EARTH/FLOOR 1 FEEDER INDENTIFICATION, SEE SCHEDULE 744 1 > CT SEE GENERAL NOTE #8 WP WEATHERPROOF SPACE ONLY a,b,c INDICATES SWITCHING SCHEME SPACE ONLY * - PROVIDE WITH POWERPACK AND FACTORY SETUP AT SITE. WIRE TO CONTROL LIGHTS IN AREA. AF AF AF GFEP AF AF AF PANELBOARD G (TYPICAL OF 118 REQUIRED) MIN. SIZE LOAD CENTER CONSTRUCTIONRQ'D BUS AMPS: 125A LOCATION: ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 1PH, 3W AFC VALUE: 30,712A FEED THRU LUGS: YES MOUNTING: RECESSED AIC RATING: 42,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P ' THRU WALL OUTLET, 20A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO PTAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. -,-mow,-,W1-eW^r,'v -'e,,e, * P AMPS 1 ROOM RCPT AND LIGHTING 20 1 12 1,480 3,280 1,800 12 1 20 REFRIGERATOR 2 3 TOILET RECEPTACLE 20 1 12 1,694 2,894 1,200 12 1 20 MICROWAVE 4 5 KITCHEN 20 1 12 1,500 3,000 1,500 12 1 20 KITCHEN 6 7 PTAC 15 2 12 1,250 2,450 1,200 12 2 20 RANGE 8 9 1,250 2,450 1,200 10 11 DISHWASHER 20 1 12 744 744 0 SPACE ONLY 12 13 SPACE ONLY 0 0 0 SPACE ONLY 14 15 SPACE ONLY 0 0 0 SPACE ONLY 16 PER PHASE SUB -TOTALS 8,730 6,088 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 14,818 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 71 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 14,833 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 71 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM *- PHASES VARY DEPENDING ON FEEDER FROM PANELBOARDS 'DP1' AND 'DP2'. AF - COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTER B-31 NOTES: 1. LIGHTING CONTACTORS ARE SHOWN DE -ENERGIZED, THEREFOR THE LIGHTING WOULD BE ON. 2. PROGRAM: ON AT SUNSET/OFF AT SUNRISE.VERIFY PROGRAMMING WITH OWNER. SPECIAL OUTLET SCHEDULE SYMBOL DESCRIPTION ® A THRU WALL OUTLET, 15A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO I5TAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. ® B RANGE CONNECTION. NEMA 14-20, 20A, 208V, 1PH PLUS GROUND. FLUSH WALL MOUNTED J -BOX FOR RANGE POWER CONNECTION. VERIFY MOUNTING HEIGHT. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH OWNER PRIOR TO ROUGH -IN AND PROVIDE ACTUAL SIZE OF BREAKER, WIRE, AND CONDUIT REQUIRED FOR EACH UNIT. SECURE RANGE CORD TO BACK WALL OF CABINET CLEAR OF SHELF IN CABINET BASE. ®* C DRYER OUTLET. NEMA 14-30R, 30A, 3 POLE, 4 WIRE LEVITON #278. FLUSH MOUNTED OUTLET, PROVIDE WITH LEVITON #4944 2 -GANG COVERPLATE. MOUNT AT 48" A.F.F. ROUTE 3#10 & 1#10 FROM OUTLET TO PANEL. PROVIDE DRYER WITH 4 WIRE CORD AND PLUG AS REQUIRED. ® D CCTV CAMERA LOCATION. PROVIDE AND INSTALL FLUSH MOUNTED SINGLE GANG J -BOX AT LOCATION SHOWN. ROUTE (1) 1" CONDUIT FROM BOX TO NEAREST CORRIDOR CEILING CAVITY. PROVIDE CAT 5e CABLE, YELLOW, 4 PAIR FROM BOX TO FIRST FLOOR ELECTRICAL ROOM CAMERA CONNECTION LOCATION. PROVIDE 18" CABLE STUB OUT AT DOUBLE GANG BOX AND 48" CABLE STUB OUT AT FIRST FLOOR ELECTRICAL ROOM CONNECTION LOCATION. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO ROUGH- IN. CONFIRM THAT EXIT SIGN DOES NOT BLOCK CORRIDOR VIEW OF CAMERA. ® E CCTV CAMERA AUDIO LOCATION. PROVIDE AND INSTALL FLUSH MOUNTED J -BOX AT LOCATION SHOWN. ROUTE (1) 1-1/2" CONDUIT FROM BOX TO NEAREST CORRIDOR CEILING CAVITY. PROVIDE CAT 5e CABLE, YELLOW, 4 PAIR FROM BOX TO SECOND FLOOR ELECTRICAL ROOM CAMERA CONNECTION LOCATION. PROVIDE 18" CABLE STUB OUT AT DOUBLE GANG BOX AND 48" CABLE STUB OUT AT SECOND FLOOR ELECTRICAL ROOM CONNECTION LOCATION. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. ®F 20A, 125V, DUPLEX GROUNDED RECEPTACLE MOUNTED IN CEILING FOR CONNECTION OF WIRELESS ACCESS POINT. SPECIFIC LOCATIONS SHOULD BE VERIFIED WITH THE OWNER'S TELECOM VENDOR. ®G THRU WALL OUTLET, 20A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO PTAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. -,-mow,-,W1-eW^r,'v -'e,,e, ® H CARD READER. COORDINATE WITH EQUIPMENT SUPPLIER FOR ALL REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS. CIRCUIT AS SHOWN ON PLANS. * - VERIFY WIRING AND RECEPTACLE FOR DRYER CONNECTIONS WITH OWNER PRIOR TO ROUGH - IN. DRYER CONNECTION MUST COMPLY WITH N.E.C. ARTICLE #250.140. TIME POWER th 4 0 ELECTRONIC TIME SWITCH WITH FULL YEAR AND ASTRONOMIC PROGRAMMING IN NEMA -1 ENCLOSURE MOUNTED ADJACENT TO PANEL 'A'. 20 A., 12P., 240V. ELECTRICALLY HELD LIGHTING CONTRACTOR WITH NORMALLY CLOSED CONTACTOR AND 120V. CONTROL COIL. A-30 ,(/-•-� EXT LTG A-41 xr--v EXT LTG A-1 A-16 A-32 A-38 A-21 1/--II0- SITE LTG ,j/-® SITE LTG ,4/-01.-- SITE LTG J/ -u.- PYLON SIGN {/® PYLON SIGN XI XI XI XI SPARE SPARE SPARE SPARE SPARE A-4 / - A-6 A-39 i3UILDING SIGN BUILDING SIGN CANOPY SPARE NEMA 1 ENCLOSURE AND RELAYS TO BE MOUNTED NEXT TO PANEL 'A'. 20 A., 4P., 240V. ELECTRICALLY HELD LIGHTING CONTRACTOR WITH NORMALLY CLOSED CONTACTOR AND 120V. CONTROL COIL. 41) EXTERIOR LIGHTING CONTROL SCALE: NOT TO SCALE GENERAL NOTES iEVIEWED .FOR MPLIANCE WITH !FPA 70 $ 1F( OC I 0 7017 City of Tukwila UILDINp DIVISION AF AF AF 1. VERIFY ALL OUTLET LOCATIONS ON THE JOB PRIOR TO ROUGH -IN. 2. REFER TO RELATED ARCHITECTURAL, MECHANICAL, AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION. 3. REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. 4. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING OF BRICK BLOCK. 5. ALL MOUNTING HEIGHTS TO BOTTOM OF ITEM UNLESS OTHERWISE NOTED. 6. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UMTS AND THERMOSTAT LOCATIONS. 7. RUN CONDUIT W/ CONDUCTORS AS INDICATED, CONDUIT SIZE AS REQUIRED. CONDUIT RUN TO PANEL DEVICE SIZE AS INDICATED (AMP/POLE). CIRCUIT WITHOUT INDICATION IS ROUTED TO 20A., 1P. BREAKER. DO NOT RUN MULTIPLE CIRCUITS IN ONE CONDUIT. 8. "CT" INDICATED ADJACENT TO DEVICE INDICATES DEVICE IS MOUNTED ABOVE BACKSPLASH OF COUNTER TOP. VERIFY EXACT HEIGHT WITH ARCHITECTURAL PLANS AND ELEVATIONS. 9. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER, RECEPTACLE, AND LIGHTING CIRCUITS. GROUND CONDUCTORS ARE NOT SHOWN ON DRAWINGS. 10. TYPE NM, AC, OR MC CABLE MAY BE USED WHERE ALLOWED BY THE APPLICABLE EDITION OF THE N.E.C. AND WHERE ACCEPTABLE TO THE LOCAL AUTHORITY HAVING JURISDICTION. VERIFY PRIOR TO BID. 11. COLOR CODING FOR COMMUNICATIONS CABLING SHALL BE GREY OR WHITE FOR TELEPHONE, BLUE FOR DATA, BLACK FOR CATV, AND YELLOW FOR CAMERAS. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO BID. 12. OUTLET BOXES FOR LIGHTING AND DEVICES SHALL BE MINIMUM REQUIRED BY CODE FOR INSTALLATION SHOWN. 13. WHEN INSTALLING ELECTRICAL OUTLET BOXES IN SHEAR WALLS, CONTRACTOR RECEI SHALL CUT APPLICABLE OPENINGS NEATLY AND IN ACCORDANCE WITH MAINMINCIOF STRUCTURAL, FIRE, AND SOUND RATINGS. 14 IN ALL AREAS SPECIFIED BY 210.52 (NEC 2014), ALL NONLOCKING -TYPE 15 AND 20 stip RECEPTACLES SHALL BE TAMPER-RESISTANT RECEPTACLES. 15. MINIMUM WIRE SIZE FOR A 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIS DISTANCE AS FOLLOWS DISTANCE SHALL BE MEASURED FROM THE PANELBOAR i'► IT C CIRCUIT BREAKER TO THE FARTHEST OUTLET. ALL WIRE SIZES MAY BE REQUIRED TO BE LARGER DEPENDING ON CONDUIT AND CONDUCTOR ROUTING AND LOAD ON CIRCUIT. #12 FOR LESS THAN 100 FEET. #10 BETWEEN 100 AND 150 FEET. #8 BETWEEN 150 AND 250 FEET. #6 FOR ANYTHING OVER 250 FEET. VE UK B R R Architect of Record: BRR Architecture, Inc. Kansas City ' 6700 Antioch Plaza Bentonville Suite 300 Phoenix ' Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa. Kansas 66215 P9133225150 • F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES'" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal 2017 Sheet Title ENTER ELECTRICAL PANELS AND SCHEDULES Sheet No. E-2 0BRR Original printed on recycled paper xc/s B-13 (9 B-15 WP/GFCI C-28,30 0A ®A B-13 B-13 DOUBLE..... QUEEN SUITE..........., 11311 ELEVATOR MACHINE ROOM ..................... STAIRS.. GUEST LAUNDRY DOUBLE QUEEN_ SUITE I ACC °QUEEN__ FAMILY SUITE MDP -5 B 18 XC B-1 B-42 H �N ALL A NDING FITNESS B-13 BA A m.: EB -13 B-13 ..B-1,3 \ DOUBLE QUEEN SUITE ELEVATOR KEYNOTES ( 1 , 2 , x ) 1. PROVIDE (1) 200A, 3P, 208V BUSSMAN POWER MODULE W TH SHUNT TRIP MECHANISM WITH 175A FUSES FOR ELEVATOR EQUIPMENT PER MANUFACTURER REQUIREMENTS. LOCATE DISCONNECT IN FIRST FLOOR ELEVATOR ROOM. COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER. PROVIDE ALL WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. 2. ELEVATOR POWER UNIT. COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER. PROVIDE ALL WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. 3. 30 AMP, 125 VOLT ELECTRICAL DISCONNECT FUSED AT 20 AMPS FOR ELEVATOR CAB POWER (LIGHTING/HVAC). VERIFY ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER PRIOR TO ROUGH -IN. 4. TELEPHONE OUTLET J -BOX MOUNTED ON WALL AT 48" AFF. TO TOP. PROVIDE 3/4" CONDUIT WITH PULLWIRE TO ELEVATOR CONTROLLER OR AS DIRECTED BY ELEVATOR MANUFACTURER, AND 3/4" CONDUIT BACK TO TELEPHONE TERMINAL BOARD. CONNECTION TO CAB BY OTHERS. PROVIDE 8' OF SLACK CABLE AT ELEVATOR CONTROLLER. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. CORRIDOR E XA- B-13 A m I® B 13W E B-13 ELECTRICAL ROOM 11451 B-15 MECHANICAL ROOM QUEEN SUITE LOBBY STAFF LAUNDRY DOUBLE - QUEEN SUITE 11221 DELUXE CORNER SUITE -TRAINING ESTIBULE 11351 C-17 C C-17 ROUTE 1" CONDUIT UNDERGROUND FROM ELECTRICAL ROOM TO BLADE WALL. COORDINATE WITH ARCHITECT FOR FINAL LOCATION. MOTORIZED DAMPER: INTERLOCK DAMPER TO OPEN WHEN ANY DRYER IS ON. 7-XGn B-13 A-39 QUEEN \ SUITE Am A-39 A-39 A 0 --- A 0 A-39 A-39 1� FIRST FLOOR ELECTRICAL PLAN SCALE: 1/8" = 1'-0" D-21,23 CI D-29,31 D-39,41 OS +48"1 N A D-14 A-14 D-14 SA D-14 D-38, 6" AS AS D-14 D-14 D-14 FSD D-36 Ae D-14 A® D-14 D-32 GFCI PNLBD 'D' C -25- D-28_ __A GFCI D-14 A® D-14 D-14 D-33......'.....- GFCI AS D-14 B-1 D-16 GFCI A0 D-14 D-1 A D-14 A-14 D-14 A D-145 a AS E D-14 D-1ni ®A �A D-14 D-14 BA 3 A 0-145 a A D-145 a E AS D-14 A D-14 D-14 5 D-14 MOUNT ABOVE WASH MACHINE FOR SOAP DISPENSER. VERIFY MOUNTING HEIGHT. D-14 A A D-14 ® D-14 A® D-14 A D-14 D-16 ........C..... GFCI AS D-14 D-16 B-1 A D-145 a D-1451 a D-10,12 A A D-14 D_ 14 5 D-14 \3\ ENLARGED LAUNDRY SCALE: 1/4" = 1'-0" 9/7/2017 4:35:56 PM SD D-36 E' A S D-1 D-14 FSD D-36 XA D-14 ® B-14 NEMA -1 60/2/40 +48" AL9 D-14 A -� D-14 E D-14 A A D-14 D-14 NEMA -1 30/3/20 MOUNT RCPT FOR HEAT RACE AT CEILING. XA ® D-14 A-26,28 C A-17,19 D-4 0-18 WP/GFCI �2\ ENLARGED LOBBY SCALE: 1/4" = NEMA -1 30/2/15 PLAN KEYNOTES 2 X 1. 5 TELEPHONE JACKS AND 3 DATA JACKS. TEL#1-FAX, TEL#2-CALL ACCOUNTING, TEL#3-EVENT LOGGER, TEL#4-CREDIT CARD BACKUP, TEL#5-EXT. 355, DATA#1-OFFICE COMPUTER, DATA#2-SECURITY SYSTEM, AND DATA#3-SECURITY MICROPHONE. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. 2. 2 TELEPHONE JACKS AND 2 DATA JACKS. TEL#1-SWITCHBOARD, TEL#2-EXT. 510, DATA#1-INTERNET, AND DATA#2-INTERNET. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. 3. PUSHBUTTON FOR FRONT ENTRY DOORS. 4. PROVIDE CIRCUIT AS SHOWN ON PLANS FOR FRONT DOOR MAG LOCK SYSTEM. COORDINATE ALL REQUIREMENTS WITH MANUFACTURER AND PROVIDE ALL LOW VOLTAGE WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. REFER TO KEYNOTE 3 OFFICE REQUIREMENTS. 5. PROVIDE (2) JUNCTION BOXES. FIRST JUNCTION BOX FOR INTERCOM AND SECOND JUNCTION BOX FOR READER. PROVIDE (1) 3/4" CONDUIT FOR EACH 6. PROVIDE (1) DATA PORT, (1) GFCI RECEPTACLE, AND (1) WAP. MOUNT ALL ON WALL, REFER TO ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS. REVIEWED FOR COMPLIANCE WITH NFPA7OmNEC OCT 0 4 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 18 2017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa. Kansas 66215 P 913 322 5150 4 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL PLANS - FIRST FLOOR Sheet No. E-3 0BRR Original printed on recycled paper 9/7/2017 4:35:59 PMN B R R Architect of Record: BRR Architecture, Inc. Kansas City Bentonville Phoenix San Francisco Philadelphia Atlanta Miami 6700 Antioch Plaza Suite 300 Merriam, KS 66204 Tel: 913-262-9095 Fax: 913-262-9044 Consultants UTILITY ROOM DOUBLE QUEEN SUITE DELUXE___ KING C-11 C-11 DOUBLE QUEEN SUITE DOUBLE QUEEN SUITE -- FSD C-27 A Am 0-110 0-11 DOUBLE' QUEEN SUITE C-11 C-11 C-1 oA ® o A XA C-111 C-11 E C-11 QUEEN SUITE DOUBLE QUEEN SUITE LG. ACC. DELUXE KING DOUBLE QUEEN SUITE DOUBLE QUEEN SUITE.,,.,...... NOTE: COORDINATE FINAL LOCATION AND QUANTITY OF J -BOXES FOR SIGNAGE WITH ARCHITECT AND SIGN VENDOR PRIOR TO ROUGH -IN. WP J -BOX FOR BUILDING SIGNAGE. ROUTE VIA CONTACTOR. QUEEN SUITE \' C-11 y` E C-11 QUEEN SUITE` Aa \ C-11 CIDFOURTH FLOOR ELECTRICAL PLAN SCALE: 1/8" = Aa C-11 C-3, 0-16,18 NEMA -3R 60/2/35 NEMA -3R 30/2/20 NOTE: COORDINATE FINAL LOCATION AND QUANTITY OF J -BOXES FOR SIGNAGE WITH ARCHITECT AND SIGN VENDOR PRIOR TO ROUGH -IN. 0-20,22 NEMA -3R WP J -BOX FOR BUILDING SIGNAGE. ROUTE VIA CONTACTOR. 0-24,26 ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcerlusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal OCT 0 4 2017 ELECTRICAL ROOF PLAN SCALE: 1/8" = EXPIRES: 09/21/17 Sheet Title ELECTRICAL PLANS - FOURTH FLOOR Sheet No. E-6 0 BRR Original printed on recycled paper 5/24/2017 10:01:07 ANI EXTERIOR PROVIDE CT CABINET AND METERING PER UTILITY CO. STANDARDS. VERIFY ALL REQUIRMENTS PRIOR TO BID. INTERIOR G 433 MDP DP1 MDP -3 MDP -6 DP1-1 G 432 G 431 123 > < 123 G 332 G 331 G 430 G 429 123 > < 123 G 330 G 329 123 > < 123 > < 123 > < 123 G 232 G 231 G 230 G 229 123 > < 123 > < 123 > < 123 G 132 G 131 G 130 G 129 123 > < 123 > < 123 > < 123 DP1-2 DP1-3 DP1-4 DP1-5 G 428 G 427 G 426 G 425 DP1-6 DP1-7 DP1-8 DP1-9 G 424 123 G 324 123 G 224 123 G 124 < 123 > I I I I G 423 DP1-11 G 422 G 421 G 420 G 419 123 > < 123 > < 123 > < 123 G 322 G 321 G 320 G 319 123 > < 123 > < 123 > < 123 G 222 G 221 G 220 G 219 123 > < 123 > < 123 > < 123 G 122 G 121 G 120 G 119 123 > < 123 > < 123 > < 123 DP1-10 DP1-12 DP1-13 DP1-14 DP1-15 DP2 804 MDP -2 C 104 a B-37,39,41 MDP -4 DP2-1 DP2-2 DP2-3 TO ELEVATOR POWER MODULE. REFER TO SHEET E4 FOR MORE INFORMATION. DP2-4 123 G 415 123 G 315 123 G 215 123 G 115 DP2-5 DP2-6 DP2-7 123 G 413 DP2-8 DP2-9 DP2-10 DP2-11 DP2-12 DP2-13 Mt 4 4 123 > < 123 > < 123 > < 123 > < 123 > < 123 G 412 123 > < 123 G 313 G 312 G 411 123 G 311 G 410 G 409 G 408 G 407 DP2-14 DP2-15 t � t 123 > < 123 > < 123 G 406 123 > < 123 > < 123 > < 123 > < 123 G 310 G 309 G 308 G 307 G 306 G 405 G 404 123 > < 123 G 305 G 304 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 G 213 G 212 G 211 G 210 G 209 G 208 G 207 G 206 G 205 G 204 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 > < 123 G 113 G 112 G 111 G 110 G 109 G 108 G 107 G 106 G 105 G 104 SEPARATE PERMIT REQUIRED FOR: Mechanical 1604 ›- TO PAD MOUNTED UTILITY TRANSFORMER 804 >- PANELBOARD DPI BUS AMPS: 800A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 a,ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC ,VALUE: 53,028A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS _ A B C _ AMPS P 1 PANELBOARD G (3 UNITS) 125 2 RD 26,190 61,110 (1) 2-1/2"C 34,920 34,920 RD 2 125 PANELBOARD G (4 UNITS) 2 24,352 18,264 48,704 42,616 (4) 4"C (4) #600kcmil 69,840 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 4 3 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 = 24,352 24,352 24,352 26,190 RD 2 125 PANELBOARD G (3 UNITS) 6 5 PANELBOARD G (4 UNITS) 125 2 RD 34,920 69,840 61,110 = 35,600 48,704 42,616 18,264 24,352 52,380 15,000 34,920 26,190 RD 2 125 PANELBOARD G (3 UNITS) 8 7 PANELBOARD G (3 UNITS) 125 2 RD 26,190 18,264 18,264 48,704 36,528 246,617 SUB -TOTAL (VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 69,840 61,110 34,920 RD 2 125 PANELBOARD G (4 UNITS) 10 9 PANELBOARD G (3 UNITS) 125 2 RD 26,190 42,616 24,352 24,352 18,264 34,920 RD 2 125 PANELBOARD G (4 UNITS) 12 11 PANELBOARD G (3 UNITS) 125 2 RD 26,190 69,840 61,110 48,704 42,616 24,352 18,264 69,840 34,920 34,920 RD 2 125 PANELBOARD G (4 UNITS) 14 13 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 48,704 48,704 34,920 34,920 0 2 2 125 SPARE 16 15 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 0 24,352 0 2 125 SPARE 18 17 SPARE 125 2 0 0 0 0 0 0 0 2 125 SPARE 20 19 SPARE 125 2 0 0 0 0 PER PHASE SUB -TOTALS 299,002 250,068 251,102 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 800,172 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 2,221 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 143,153 FA -FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 397 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM 416 PANELBOARD DP2 BUS AMPS: 800A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 22,157A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 PANELBOARD G (4 UNITS) 125 2 RD 34,920 69,840 (1) 2-1/2"C 34,920 RD 2 125 PANELBOARD G (4 UNITS) 2 24,352 24,352 - 48,704 1604 > (4) 4"C (4) #600kcmil 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 4 3 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 100% = 24,352 24,352 34,920 RD 2 125 PANELBOARD G (4 UNITS) 6 5 PANELBOARD G (4 UNITS) 125 2 RD 34,920 35,600 69,840 100% = 35,600 48,704 24,352 24,352 69,840 = 15,000 34,920 RD 2 125 PANELBOARD G (4 UNITS) 8 7 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 DP2 DEMAND = 48,704 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 246,617 SUB -TOTAL (VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 10 9 PANELBOARD G (4 UNITS) 125 2 RD 34,920 48,704 24,352 24,352 34,920 RD 2 125 PANELBOARD G (4 UNITS) 12 11 PANELBOARD G (4 UNITS) 125 2 RD 34,920 69,840 48,704 24,352 24,352 69,840 34,920 RD 2 125 PANELBOARD G (4 UNITS) 14 13 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 24,352 48,704 34,920 0 2 125 SPARE 16 15 PANELBOARD G (4 UNITS) 125 2 RD 34,920 24,352 0 24,352 0 2 125 SPARE 18 17 SPARE 125 2 0 0 0 0 0 0 0 2 125 SPARE 20 19 SPARE 125 2 0 0 0 0 PER PHASE SUB -TOTALS 331,280 285,792 272,008 _ LEGEND: TOTAL CONNECTED PANELBOARD (VA) 889,080 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 2,468 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 150,028 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 416 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM 204 FEEDER SCHEDULE FEEDER TAG (QUANTITY) CONDUIT SIZE (QUANTITY) CONDUCTOR SIZE GROUND:;. SIZE _ ISOLATED ' GROUND SIZE EACH CONDUIT 104 > (1) 1-1/4"C (4) #3 #8G - 125% 123 > (1) 1-1/2"C (3)#1 #6G - 125% 204 > (1) 2"C (4) #3/0 #6G - 125% 224 > (1) 2-1/2"C (4) #4/0 #4G - 0 804 > (2) 4"C (4) #500kcmil #1/0G - 100% 1604 > (4) 4"C (4) #600kcmil NOTE 1 - 100%;50% NOTE 1: PER ARTICLE 250.92 CONTRACTOR SHALL INSTALL #3/0 BONDING CONDUCTOR FROM EACH SERVICE ENTRANCE CONDUIT TO NEUTRAL BUS IN 'MDP' PROVIDE ALL BONDING OF EQUIPMENT AS REQUIRED. COMMERCIAL LOAD SUMMARY BUILDING AREA: 48,558 SQ. FT VOLTAGE: 208Y/120V, 3PH, 4W LOAD DESCRIPTION CONNECTED LOAD (VA) CIRCUIT DESCRIPTION DEMAND FACTOR WIRE SIZE DEMAND LOAD (VA) LIGHTING POWER & HVAC INTERIOR LIGHTING 6,379 x 125% = 0 EXTERIOR LIGHTING 10,189 x 125% = 12,736 SIGNAGE 13,800 x 125% - 17,250 MINIMUM GENERAL LIGHTING PER NEC -220 x 125% 21,821 MINIMUM TRACK LIGHTING/SHOW WINDOW PER NEC -220 x 125% 0 PANELBOARD DP2 2 EXISTING 0 x 100% = 0 RECEPTACLES 15,330 x 100%;50% = 12,665 MISCELLANEOUS EQUIPMENT 93,998 x 100% = 93,998 REFRIGERATION EQUIPMENT 0 x 100% = 0 KITCHEN 0 x 100% = 0 HVAC - SUMMER 0 x 100% = 0 HVAC - WINTER 35,600 x 100% = 35,600 SUPP. ELECTRIC HEAT 15,000 x 100% = 15,000 MOTORS 13,121 x 100% = 13,121 LARGEST MOTOR 43,200 x 25% = 10,800 DP1 DEMAND = 143,153 DP2 DEMAND = 150,028 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 246,617 SUB -TOTAL (VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) SPARE CAPACITY (AMPS) 526,171 685 1,461 1,439 1,600 139 ELECTRICAL RISER DIAGRAM SCALE: NOT TO SCALE REVISIONS �' No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fee Permit FILE COPY �o. BLV7-03R$ Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiaid Copy and conditions is acknowledged: By: Date: .,2//1127 City of Tukwila BUILDING DIVISION S ❑ ectrical SU Plumbing t4as Piping City of Tukwila BUILDING DIVISION GENERAL NOTES 1. IF REQUIRED BY LOCAL CODE, ELECTRICAL CONTRACTOR SHALL PROVIDE SHUNT TRIP BREAKERS IN PANEL MDP AND REMOTE EXTERIOR LOCAKBLE BUILDING POWER OFF DEVICE TO ACTIVATE SHUNT TRIPS TO KILL ALL POWER TO BUILDING. IF UTILITY COMPANY AVAILABLE FAULT CURRENT EXCEEDS 65K AIC, PROVIDE CURRENT LIMITERS ON EACH SERVICE ENTRANCE CONDUCTOR. VERIFY ALL REQUIREMENTS WITH THE LOCAL AUTHORITY HAVING JURISDICTION PRIOR TO BID. 2. CONTRACTOR SHALL VERIFY WITH THE OWNER IF LIGHTNING PROTECTION IS REQUIRED ON THE PROJECT. LIGHTNING PROTECTION SHALL BE INCLUDED IN BID WHEN REQUIRED. 3. ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT SHALL BE MOUNTED ON 6" HIGH CONCRETE HOUSEKEEPING PAD. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT GEAR PROVIDED FOR PROJECT FITS IN THE SPACE PROVIDED. 5. ALL WIRING IS TO BE COPPER. 6. AVAILABLE FAULT CURRENT AT UTILITY IS ASSUMED TO BE 66,094A. VERIFY WITH UTILITY. CO. AND NOTIFY ENGINNER IF THERE ARE ANY DISCREPANCIES. INTERSYSTEM BONDING TERMINAL BAR. WALL MOUNTED ADJACENT TO MDP. #6 CU -3/4" C. TO TELEPHONE TERMINAL BOARDS. SEPARATE GROUNDING ELECTRODE REQUIRED FROM EACH TELE. BOARD. COLUMN #6 CU CONDUCTOR CONCRETE ENCASED ELECTRODE PER ARTICLE 250.52.A.3 OF THE NEC. CADWELL CONNECTION TO COLUMN ELECTRODE AND GROUND ROD. PANELBOARD MDP BUS AMPS: 1600A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 / SE RATED ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 58,889A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A FULLY RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER _ WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS . P A ' B C P AMPS 1 PANELBOARD DP1 800 3 RD 299,002 630,282 331,280 RD 3 800 PANELBOARD DP2 2 250,068 535,860 285,792 251,102 523,110 272,008 3 PANELBOARD A 225 3 RD 17,812 45,318 27,506 RD 3 225 PANELBOARD D 4 18,567 41,672 23,105 19,414 45,728 26,314 5 ELEVATOR 70 3 RD 3,868 30,656 26,788 RD 3 225 PANELBOARD B 6 3,868 28,934 25,066 3,868 - 29,185 25,317 PER PHASE SUB -TOTALS 706,256 606,466 598,023 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 1,910,745 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 5,304 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 518,491 FA - FIRE ALARM / RED / LOCKING TAB IG -ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 1,439 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM PANEL TO HAVE BUILT-IN SPD WITH 240 KA SURGE RATING. BONDED NEUTRAL BUS WATER PIPE GROUND LOCATED ON HOUSE SIDE OF MAIN VALVE AT POINT SERVICE ENTERS THE BUILDING. MAIN WATER AND GAS SERVICE MAIN BONDING JUMPER. FURNISHED W/ SWITCHBOARD. MAIN PANEL OR DISC. DEVICE 6" HIGH CONCRETE BASE BONDING JUMBERS TO BUILDING STEEL AND WATER SERVICE. #3/0-3/4" C. PROVIDE JUMPER OVER ISOLA GROUNDING ELECTRODE CONDUCT 3/4" X 10' COPPERCLAD DRIVEN GROU ROD IN ROOM. PROVIDE NUMBER REQUIRED FOR A MAXIMUM 25 OHM RESISTANCE TO GROUND. SYSTEM GROUNDING DETAIL SCALE: NOT TO SCALE REVIEWED FOR COMPLIANCE WITH NFPA 70 a NEC JUN 30 2017 LOck City o Tukwila BUILDING DIVISION JM 2 1a CITY OF TUKWILA MAY 252017 PERMIT CENTER F157-- 039 g B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 9 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West. Valley Highway,, Tukwila, WA 98188 • WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL RISER DIAGRAM Sheet No. E-1 0 BRR Original printed on recycled paper GF GF EM GF FA EM 5/24/2017 10:01:10 AM PANELBOARD A BUS AMPS: 225A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 49,449A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 STAFF WASHER 20 3 8 1,733 3,557 3,339 1,824 8 1 20 EXTERIOR LIGHTING SITE 2 1,920 6 1 20 BUILDING SIGNAGE 4 1,733 FIRST FLOOR PTAC-2 3,653 2 3 1,750 GUEST DRYER 3,653 1,920 4 1 20 BUILDING SIGNAGE 6 1,733 5 1,680 35 FCU -2 180 12 1 20 RECEPTACLES 8 7 EUH-2 20 2 8 1,500 744 12 1 20 WATER HEATER 10 1,500 1,500 2,244 2,950 9 12 1 2,477 744 12 1 20 WATER HEATER 12 11 STAFF WASHER 20 3 8 1,733 2,477 1 20 744 12 1 20 WATER HEATER 14 1,733 13 1,824 6 1 20 EXTERIOR LIGHTING SITE 16 1,733 20 3,557 16 15 FIRST FLOOR RCPT 20 2,540 1,750 6 2 20 FIRST FLOOR PTAC-2 18 17 STAFF DRYER 15 2 8 790 20 2,540 17 ROUTER 1,750 790 19 1,750 12 2 20 SECOND FLOOR PTAC-2 22 21 PYLON SIGN 20 1 6 1,200 20 2,950 12 24 1,000 12 2,950 1,750 23 PYLON SIGN 20 1 6 1,200 1,990 1,000 TREADMILL 790 8 2 15 STAFF DRYER 26 25 PYLON SIGN 20 1 6 1,200 28 790 Y7 BOOSTER PUMP (IF REQUIRED) 20 3 12 1,272 27 2,062 25 VENDING 20 2,472 1,200 8 1 20 EXTERIOR LIGHTING 30 1,272 29 3,096 FACP 20 1,824 6 1 20 EXTERIOR LIGHTING SITE 32 1,272 31 1,500 10 2 20 EUH-4 34 33 BOOSTER PUMP (IF REQUIRED) 20 3 12 1,272 1,000 2,772 1,700 36 2,772 1,500 1,272 35 2,472 12 1,200 6 1 20 PYLON SIGN 38 1,272 37 1,200 6 1 20 PYLON SIGN 40 39 EXTERIOR LIGHTING 20 1 8 129 2 1,329 EUH-1 36 2,550 1,200 6 1 20 PYLON SIGN 42 41 EXTERIOR LIGHTING 20 1 8 1,350 PER PHASE SUB -TOTALS 17,812 18,567 19,414 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 55,793 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 155 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 60,591 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 168 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM C - ROUTE VIA CONTACTOR PANELBOARD B BUS AMPS: 225A LOCATION: ELECTRICAL ROOM 145 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 45,110A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 65,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 RECEPTACLES 20 1 12 1,080 2,160 3,339 1,080 12 1 20 SECOND FLOOR RCPT 2 1,750 6 2 20 SECOND FLOOR PTAC-2 4 3 FIRST FLOOR PTAC-2 20 2 12 1,750 GUEST DRYER 3,500 2 6 2,600 5 3,500 1,750 1,750 5 2,950 35 FCU -2 1,450 12 2 20 ELECTRIC ROOM PTAC-3 8 7 VENDING 20 1 8 1,500 10 1,450 9 VENDING 20 1 8 1,500 40 2,950 908 12 1 1,239 879 12 1 20 LIGHTS & EM LIGHTS , 12 11 RECEPTACLES 20 1 12 360 1,770 1 20 500 12 1 20 FRONT DOOR MAG -LOCK SYSTEM 14 13 LIGHTS & EM LIGHTS 20 1 12 1,270 180 12 1 20 ELEVATOR PIT 16 15 FIRST FLOOR RCPT 20 1 12 1,620 2,600 1,800 2,420 1,880 17 1,500 1,000 10 1 20 ELEVATOR CAB 18 17 ROUTER 20 1 12 500 2,170 19 ELIPTICAL 1,170 10 1 20 SUMP PUMP 20 19 CATV 20 1 12 1,000 1,000 12 1 20 DTB 22 21 ITB 20 1 12 1,000 TREADMILL 2,000 1 12 500 2,500 1,500 6 2 20 EUH-5 24 23 TTB 20 1 12 1,000 26 3,000 28 27 1,500 25 VENDING 20 1 8 1,500 204 12 1 20 RCP -1 28 27 FACP 20 1 12 1,000 1 1,204 0 PER PHASE SUB -TOTALS 11,538 12,002 10,728 2,500 1,500 12 2 20 EUH-3 30 29 WIRELESS ACCESS POINTS 20 1 12 1,000 32 1,700 1,356 1,500 31 TIME CLOCK 20 1 12 200 180 12 1 20 TWO-WAY COMM. STATION 34 33 UTILITY ROOM 240 PTAC-1 15 2 12 1,250 1,430 37 2,750 1,500 12 2 20 EUH-1 36 1,250 35 38 1,500 13,038 2,600 37 PANELBOARD 'C' 100 3 RD 11,538 : s 2,600 - - P!6 l• C ' i' 12,002 0 12,182 1 39 SPARE 11,328 600 10 1 20 CARD READERS 42 10,728 41 PER PHASE SUB -TOTALS 26,788 25,066 25,317 - - \ •: TOTAL CONNECTED PANELBOARD (VA) 77,171 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 214 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 75,863 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 211 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM PANEL TO HAVE BUILT-IN SPD WITH 120 KA SURGE RATING. PANELBOARD C BUS AMPS: 100A LOCATION: UTILITY ROOM 340 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 5,493A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 10,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # P AMPS A B C AMPS P 1 FOURTH FLOOR RCPT 20 1 12 1,080 2,340 3,339 1,260 12 1 20 THIRD FLOOR RCPT 2 1,750 8 2 20 THIRD FLOOR PTAC-2 4 3 FOURTH FLOOR PTAC-2 20 2 8 1,750 GUEST DRYER 3,500 2 6 2,600 5 3,500 1,750 1,750 5 3,500 35 FCU -2 1,750 8 2 20 THIRD FLOOR PTAC-2 8 7 FOURTH FLOOR PTAC-2 20 2 8 1,750 10 1,750 1,750 4,417 3,500 3,241 9 2 40 1,802 908 12 1 20 THIRD FLOOR LIGHTS, EM LTG, & EF -6 12 11 FOURTH FLOOR LIGHTS, EM LTG, & EF -2 20 1 12 894 720 GUEST DRYER 30 360 12 1 20 THIRD FLOOR UTILITY RCPT 14 13 FOURTH FLOOR UTILITY RCPT 20 1 12 360 1,880 8 2 35 HP -1 16 15 WIRELESS ACCESS POINTS 20 1 12 1,000 GUEST DRYER 2,880 2 18 2,600 HUBBELL 2,420 1,880 17 FITNESS RCPT 20 1 12 540 1,722 2,780 TS - VIA TIME SWITCH ST - SHUNT TRIP 1,222 12 2 20 HP -2 20 19 ELIPTICAL 20 1 12 500 22 1,222 21 SPARE 20 1 12 0 20 1,222 22 2,600 3,006 2,506 8 2 50 HP -3 24 23 TREADMILL 20 1 12 500 26 2,506 3,256 4,100 25 FITNESS TELEVISION 20 1 12 750 500 12 1 20 TREADMILL 28 27 MOTORIZED DAMPERS 20 1 12 400 28 900 GUEST DRYER 30 0 0 2,600 1 20 SPARE 30 29 SPARE 20 1 30 0 PER PHASE SUB -TOTALS 11,538 12,002 10,728 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 34,268 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 95 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 32,448 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 90 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM 1,176 C C C C C C AF AF EM PANELBOARD D BUS AMPS: 225A LOCATION: GUEST LAUNDRY 142 GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 3PH, 4W AFC VALUE: 9,875A FEED THRU LUGS: NO MOUNTING: SURFACE AIC RATING: 10,000A SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P A B C P AMPS 1 GUEST WASHER 20 1 12 1,176 4,136 3,339 2,960 8 2 40 FCU -1 2 3 GUEST WASHER 20 1 12 1,176 12 4,136 - A / L'1 2,960 4 5 GUEST DRYER 30 2 10 2,600 5 KITCHEN 5,477 2,877 8 2 35 FCU -2 6 7 2,600 5,477 20 KITCHEN 2,877 8 9 GUEST WASHER 20 1 12 1,176 WALL FLOOR/SEE ARCH. DRAWINGS FOR LOCATION 4,417 1,200 3,241 8 2 40 FCU -3 10 11 GUEST WASHER 20 1 12 1,176 11 PTAC - LIVING ROOM 4,417 3,241 12 13 GUEST DRYER 30 2 10 2,600 4,049 20 LIVING ROOM RCPTS 1,449 12 1 20 GUEST LAUNDRY/LOBBY LIGHTS 14 2,600 12 3,860 20 15 1,260 12 1 20 GUEST LAUNDRY RCPT 16 17 GUEST DRYER 30 2 10 2,600 HUBBELL PG -Z 3,320 720 12 1 20 STAFF LAUNDRY RCPT 18 2,600 2,780 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 19 180 12 1 20 REGISTRATION RCPT 20 21 GUEST DRYER 30 2 10 2,600 2,960 360 12 1 20 REGISTRATION RCPT 22 2,600 23 3,200 600 12 1 20 REGISTRATION RCPT 24 25 GUEST DRYER 30 2 10 2,600 4,100 1,500 12 1 20 STAFF MICROWAVE 26 2,600 3,776 27 1,176 12 1 20 GUEST WASHER 28 29 GUEST DRYER 30 2 10 2,600 4,100 1,500 12 1 20 STAFF REFRIGERATOR 30 31 2,600 2,780 180 12 1 20 GUEST LAUNDRY RCPT 32 33 GUEST WASHER 20 1 12 1,176 1,356 180 12 1 20 HEAT TRACE 34 35 GUEST DRYER 30 2 10 2,600 3,200 .•$ ' .10 •,' 6 II.:,(• - 4,184 37 2,600 1,584 12 1 20 COFFEE MAKER 38 39 GUEST DRYER 30 2 10 2,600 2,600 v. 2,600 41 2,600 0 1 20 SPARE 42 PER PHASE SUB -TOTALS 27,506 23,105 26,314 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 76,925 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 214 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 77,253 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 214 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM GFEP - GROUND FAULT EQUIPMENT PROTECTION PANELBOARD G2 (TYPICAL OF 4 REQUIRED) MIN. SIZE LOAD CENTER CONSTRUCTION RQD BUS AMPS: 125A LOCATION: ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 1PH, 3W AFC VALUE: 7,207A FEED THRU LUGS: YES MOUNTING: RECESSED AIC RATING: 10,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P *(VA) - LED W/UNIT P AMPS 1 LIGHTING AND BEDROOM RCPT 20 1 12 1,539 3,339 LED - 10W 120 1,800 12 1 20 REFRIGERATOR 2 3 TOILET RECEPTACLE 20 1 12 1,694 - A / L'1 n- . - •r - 2,894 1,200 12 1 20 MICROWAVE 4 5 KITCHEN 20 1 12 1,500 3,000 5'4W INCLUDED 120 1,500 12 1 20 KITCHEN 6 7 PTAC- BEDROOM 15 2 12 1,250 SURFACE/CEILING WALL FLOOR/SEE ARCH. DRAWINGS FOR LOCATION 2,450 1,200 12 2 20 RANGE 8 9 1,250 2,450 L HUBBELL 1,200 10 11 PTAC - LIVING ROOM 15 2 12 1,250 M TBD 2,330 1,080 12 1 20 LIVING ROOM RCPTS 12 13 1,250 1,994 NXPB-3-R-WH - 744 12 1 20 DISHWASHER 14 15 SPACE ONLY NXPC-3-R-WH - LED/5.4W 0 14 WHITE 0 0 XC HUBBELL PG -Z SPACE ONLY 16 PER PHASE SUB -TOTALS 10,783 BRONZE 7,674 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 18,457 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 89 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 18,487 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 89 Ei/1- EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM *- PHASES VARY DEPENDING ON FEEDER FROM PANELBOARDS'DP1' AND 'DP2'. AF - COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTER EM LIGHT FIXTURE SCHEDULE FIXTURE TAG MANUFACTURER MODEL NUMBER FLUORESCENT FIXTURE & FIXTURE LETTER VOLTAGE TOTAL VA FINISH MOUNTING REMARKS NO. TYPE LED FIXTURE & FIXTURE LETTER A SYLVANIA LED/900/LD/830/830/FL120 - LED W/UNIT 120 13 WHITE SURFACE/CEILING CORRIDOR FIXTURE B STARTEX STX-BV2-4 4 LED - 10W 120 40 NICKEL SURFACE VANITY LIGHT 1'-3" A.F.F. *i• il•- 1 • • r TOILET RECEPTACLE *-3 r 1 0 9. r - A / L'1 n- . - •r - D TEXES FLUORESCENT CERG213E120 2 13W 4 PIN 120 26 WHITE SURFACE/CEILING UTILITY LIGHT ELEVATOR PIT E JUNO N1WH 2 5'4W INCLUDED 120 11 WHITE 7'-6"AFF EMERGENCY LIGHT F RAB LIGHTING WPLED104 - LED W/UNIT 120 150 BRONZE SURFACE/CEILING WALL FLOOR/SEE ARCH. DRAWINGS FOR LOCATION G BRUCK LIGHTING 103-040-AUWH - LED W/UNIT 120 9 WHITE 7'-0" AFF CORRIDOR WALL SCONCE L HUBBELL LNC-7LU-5K4-1 - LED W/UNIT 120 16.4 BRONZE 8'-0" AFF EXTERIOR WALL PACK M TBD TBD - TBD 120 50W TBD PENDANT DECORATIVE FIXTURE XA JUNO NXPB-3-R-WH - LED W/UNIT 120 3 WHITE CEILINGNARIES EXIT LIGHT XB JUNO NXPC-3-R-WH - LED/5.4W 120 14 WHITE 7'-6" AFF EXIT/EMERGENCY LIGHT COMBO XC HUBBELL PG -Z 2 LED W/UNIT 120 3 BRONZE 7'-6" AFF EXTERIOR EMERGENCY LIGHT NOTES: HEATER IS REQUIRED. SHALL PROVIDE FIREPROOFING AROUND RECESSED FIXTURES INSTALLED IN FARE RATED CEILING PER U.L. REQUIREMENTS. FOR LAMP AND BALLAST TYPE. VERIFY LAMP COLOR WITH ARCHITECT PRIOR TO ORDERING. AND FACES AS INDICATED IN THE DRAWINGS. OF VENDORS OR PRODUCTS ON LIGHT FIXTURES UNLESS APPROVED BY WOODSPRING SUITES, THE ARCHITECT, AND OWNER. EXIT SIGN UP HIGH AND ONE DOWN LOW PER LOCAL AND NATIONAL CODES. PROVIDE INTERCONNECTION BETWEEN UNITS AS REQUIRED. 1. VERIFY IF BATTERY 2. GENERAL CONTRACTOR 3. SEE SPECIFICATIONS 4. PROVIDE ARROWS 5. NO SUBSTITUIONS 6. PROVIDE ONE SYMBOL LEGEND SYMBOL DESCRIPTION MOUNTING FLUORESCENT FIXTURE & FIXTURE LETTER CEILING (A) CONNECTED PER PHASE (VA) FLUORESCENT FIXTURE & FIXTURE LETTER CEILING 0 I CIRCUIT DESCRIPTION LED FIXTURE & FIXTURE LETTER SURF./RECESSED OA Q * 0 LED FIXTURE & FIXTURE LETTER WALL BRACKET (Si EXIT FIXTURE - SHADING DENOTES FACE(S) CEILING/WALL GFCI GFCI DUPLEX GROUNDED RECEPTACLE 1'-3" A.F.F. IP DUPLEX GROUNDED RECEPTACLE 1'-3" A.F.F. • DOUBLE DUPLEX RECEPTACLE 1'-3" A.F.F. WP/GFCI EXTERIOR GFCI RECEPTACLE WEATHERPROCF 1'-3" A.F.F. ® SPECIAL OUTLET. SEE SCHEDULE OR AS NOTED TOILET RECEPTACLE TV CATV OUTLET 1'-3" A.F.F. VDW PHONE/DATA OUTLET (W=44" A.F.F.) 1'-3" A.F.F. M WATT STOPPER DW -100 MASTER LIGHT SWITCH 4'-0" TO TOP S S2 S3 S4 SP SK SWITCHES (1, 2 -POLE, 3 -WAY, 4 -WAY, PILOT, KEY) 4'-0" TO TOP SOS OCC. SWITCH, WATTSTOPPER #PW -100-W 4'-0" TO TOP T WATT STOPPER CS -50 LIGHT/TIME DELAY FAN SW. 4'-0" TO TOP OT THERMOSTAT (BY MECH. CONTRACTOR) 4'-0" TO TOP O. * MOTION SENSOR, WATTSTOPPER W -1000A 4'-0" TO TOP J JUNCTION BOX KITCHEN =1' 0/3/240 H.D. SAFETY SWITCH (AMPS, POLE, VOLTAGE) 6'-6" TO TOP ® 0/3/240 STARTER (SIZE, POLE, VOLTAGE) 6'-6" TO TOP 1,250 BRANCH CIRCUIT PANEL & PANEL DESIGNATION 6'-6" TO TOP PNLBD'X' 1,200 CONDUIT RUN 2#12 & 1#12 GROUND - 1/2"C. CEILING/WALL 20 {-----, CONDUIT RUN 2 CIRCUIT,3#12&1#12 GROUND -1/2"C. EARTH/FLOOR \ PARTIAL HOMERUN (MULTIPLE LOAD LOCATIONS) 2,450 #10 30/3 SEE GENERAL NOTE #7 10 ./"� CONDUIT RUN W/2 HOTS, 1 NEUTRAL, & 1 GROUND EARTH/FLOOR 1 FEEDER INDENTIFICATION, SEE SCHEDULE 744 1 > CT SEE GENERAL NOTE #8 WP WEATHERPROOF SPACE ONLY a,b,c INDICATES SWITCHING SCHEME SPACE ONLY * - PROVIDE WITH POWERPACK AND FACTORY SETUP AT SITE WIRE TO CONTROL LIGHTS IN AREA. AF AF AF GFEP PANELBOARD G (TYPICAL OF 118 REQUIRED) MIN. SIZE LOAD CENTER CONSTRUCTIONRQ'D BUS AMPS: 125A LOCATION: ROOM GROUND BUS: YES MAIN SIZE / TYPE: MLO NEMA RATING: NEMA 1 ISOL. GROUND BUS: NO VOLTS/PHASE: 208Y/120V, 1 PH, 3W AFC VALUE: 30,712A FEED THRU LUGS: YES MOUNTING: RECESSED AIC RATING: 42,000 SERIES RATED SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA) WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT # AMPS P * THRU WALL OUTLET, 20A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO PTAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. * P AMPS 1 ROOM RCPT AND LIGHTING 20 1 12 1,480 3,280 1,800 12 1 20 REFRIGERATOR 2 3 TOILET RECEPTACLE 20 1 12 1,694 2,894 1,200 12 1 20 MICROWAVE 4 5 KITCHEN 20 1 12 1,500 3,000 1,500 12 1 20 KITCHEN 6 7 PTAC 15 2 12 1,250 2,450 1,200 12 2 20 RANGE 8 9 1,200 1,250 2,450 10 11 DISHWASHER 20 1 12 744 744 0 SPACE ONLY 12 13 SPACE ONLY 0 0 0 SPACE ONLY 14 15 SPACE ONLY 0 0 0 SPACE ONLY 16 PER PHASE SUB -TOTALS 8,730 6,088 LEGEND: TOTAL CONNECTED PANELBOARD (VA) 14,818 TS - VIA TIME SWITCH ST - SHUNT TRIP TOTAL CONNECTED PANELBOARD (AMPS) 71 GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB TOTAL PANELBOARD DEMAND (VA) 14,833 FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND TOTAL PANELBOARD DEMAND (AMPS) 71 EM - EMERGENCY LTG. / LOCKING TAB RD - RE: RISER DIAGRAM * - PHASES VARY DEPENDING ON FEEDER FROM PANELBOARDS'DP1' AND 'DP2'. AF - COMBINATION TYPE ARC FAULT CIRCUIT INTERRUPTER AF AF AF B-31 N NOTES: 1. LIGHTING CONTACTORS ARE SHOWN DE -ENERGIZED, THEREFOR THE LIGHTING WOULD BE ON. 2. PROGRAM: ON AT SUNSET/OFF AT SUNRISE.VERIFY PROGRAMMING WITH OWNER. SPECIAL OUTLET SCHEDULE SYMBOL DESCRIPTION ® A THRU WALL OUTLET, 15A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO PTAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. ® B RANGE CONNECTION. NEMA 14-20, 20A, 208V, 1 PH PLUS GROUND. FLUSH WALL MOUNTED J -BOX FOR RANGE POWER CONNECTION. VERIFY MOUNTING HEIGHT. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH OWNER PRIOR TO ROUGH -IN AND PROVIDE ACTUAL SIZE OF BREAKER, WIRE, AND CONDUIT REQUIRED FOR EACH UNIT. SECURE RANGE CORD TO BACK WALL OF CABINET CLEAR OF SHELF IN CABINET BASE. ®* C DRYER OUTLET. NEMA 14-30R, 30A, 3 POLE, 4 WIRE LEVITON #278. FLUSH MOUNTED OUTLET, PROVIDE WITH LEVITON #4944 2 -GANG COVERPLATE. MOUNT AT 48" A.F.F. ROUTE 3#10 & 1#10 FROM OUTLET TO PANEL. PROVIDE DRYER WITH 4 WIRE CORD AND PLUG AS REQUIRED. ® D CCTV CAMERA LOCATION. PROVIDE AND INSTALL FLUSH MOUNTED SINGLE GANG J -BOX AT LOCATION SHOWN. ROUTE (1) 1" CONDUIT FROM BOX TO NEAREST CORRIDOR CEILING CAVITY. PROVIDE CAT 5e CABLE, YELLOW, 4 PAIR FROM BOX TO FIRST FLOOR ELECTRICAL ROOM CAMERA CONNECTION LOCATION. PROVIDE 18" CABLE STUB OUT AT DOUBLE GANG BOX AND 48" CABLE STUB OUT AT FIRST FLOOR ELECTRICAL ROOM CONNECTION LOCATION. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO ROUGH - IN. CONFIRM THAT EXIT SIGN DOES NOT BLOCK CORRIDOR VIEW OF CAMERA. ® E CCTV CAMERA AUDIO LOCATION. PROVIDE AND INSTALL FLUSH MOUNTED J -BOX AT LOCATION SHOWN. ROUTE (1) 1-1/2" CONDUIT FROM BOX TO NEAREST CORRIDOR CEILING CAVITY. PROVIDE CAT 5e CABLE, YELLOW, 4 PAIR FROM BOX TO SECOND FLOOR ELECTRICAL ROOM CAMERA CONNECTION LOCATION. PROVIDE 18" CABLE STUB OUT AT DOUBLE GANG BOX AND 48" CABLE STUB OUT AT SECOND FLOOR ELECTRICAL ROOM CONNECTION LOCATION. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. ®F 20A, 125V, DUPLEX GROUNDED RECEPTACLE MOUNTED IN CEILING FOR CONNECTION OF WIRELESS ACCESS POINT. SPECIFIC LOCATIONS SHOULD BE VERIFIED WITH THE OWNER'S TELECOM VENDOR. ®G THRU WALL OUTLET, 20A, 2 POLE GROUNDING RECEPTACLE. FLUSH WALL MOUNTED NEAR LOWER RIGHT CORNER OF PTAC UNIT. VERIFY CONFIG. W/UNIT. VERIFY MOUNTING HEIGHT. MOUNT RECEPTACLE HORIZONTAL SO THAT CORD LEADS BACK TO PTAC. SEE ARCHITECTURAL ELEVATIONS. PROVIDE INSTALLATION OF ASSOCIATED WIRELESS MOTION SENSOR/DOOR SWITCH WITH EACH UNIT IN RESIDENT ROOMS. VERIFY LOCATION WITH OWNER. VERIFY ALL INSTALLATION REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SUCCESSFUL ELECTRICAL CONTRACTOR SHALL VERIFY WITH MECHANICAL PLANS AND OWNER PRIOR TO ROUGH -IN AND BID ACTUAL SIZE OF BREAKER, WIRE, CONDUIT, AND RECEPTACLE FOR EACH UNIT. ® H CARD READER. COORDINATE WITH EQUIPMENT SUPPLIER FOR ALL REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS. CIRCUIT AS SHOWN ON PLANS. * - VERIFY WIRING AND RECEPTACLE FOR DRYER CONNECTIONS WITH OWNER PRIOR TO ROUGH - IN. DRYER CONNECTION MUST COMPLY WITH N.E.C. ARTICLE #250.140. TIME POWER A-30 A-41 A-1 A-16 A-32 A-38 A-21 /�- EXT LTG /1' EXT LTG / ► SITE LTG /r ► SITE LTG /r ® SITE LTG IIS PYLON SIGN /- PYLON SIGN 11 SPARE 14 SPARE 14 SPARE �j SPARE 11 SPARE A-4 A-6 A-39 0 ELECTRONIC TIME SWITCH WITH FULL YEAR AND ASTRONOMIC PROGRAMMING IN NEMA -1 ENCLOSURE MOUNTED ADJACENT TO PANEL 'A'. 20 A., 12P., 240V. ELECTRICALLY HELD LIGHTING CONTRACTOR WITH NORMALLY CLOSED CONTACTOR AND 120V. CONTROL COIL. BUILDING SIGN BUILDING SIGN CANOPY SPARE NEMA 1 ENCLOSURE AND RELAYS TO BE MOUNTED NEXT TO PANEL 'A'. 20 A., 4P., 240V. ELECTRICALLY HELD LIGHTING CONTRACTOR WITH NORMALLY CLOSED CONTACTOR AND 120V. CONTROL COIL. EXTERIOR LIGHTING CONTROL SCALE: NOT TO SCALE .,- +•*1*M AF AF AF •kfO, Wt. REVIEWED• FOR COMPLIANCE W NFPA 70 NEC JUN 302011 City ofTukwila DIVISION BUILDING GENERAL NOTES JAN 2 2 2010 RECEIVED CITY OF TUKWILA MAY 252011 PERMIT CENTER 1. VERIFY ALL OUTLET LOCATIONS ON THE JOB PRIOR TO ROUGH -IN. 2. REFER TO RELATED ARCHITECTURAL, MECHANICAL, AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION. 3. REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. 4. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING OF BRICK BLOCK. 5. ALL MOUNTING HEIGHTS TO BOTTOM OF ITEM UNLESS OTHERWISE NOTED. 6. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS. 7. RUN CONDUIT W/ CONDUCTORS AS INDICATED, CONDUIT SIZE AS REQUIRED. CONDUIT RUN TO PANEL DEVICE SIZE AS INDICATED (AMP/POLE). CIRCUIT WITHOUT INDICATION IS ROUTED TO 20A., 1P. BREAKER. DO NOT RUN MULTIPLE CIRCUITS IN ONE CONDUIT. 8. "CT" INDICATED ADJACENT TO DEVICE INDICATES DEVICE IS MOUNTED ABOVE. BACKSPLASH OF COUNTER TOP. VERIFY EXACT HEIGHT WITH ARCHITECTURAL PLANS AND ELEVATIONS. 9. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER, RECEPTACLE, AND LIGHTING CIRCUITS. GROUND CONDUCTORS ARE NOT SHOWN ON DRAWINGS. 10. TYPE NM, AC, OR MC CABLE MAY BE USED WHERE ALLOWED BY THE APPLICABLE EDITION OF THE N.E.C. AND WHERE ACCEPTABLE TO THE LOCAL AUTHORITY HAVING JURISDICTION. VERIFY PRIOR TO BID. 11. COLOR CODING FOR COMMUNICATIONS CABLING SHALL BE GREY OR WHITE FOR TELEPHONE, BLUE FOR DATA, BLACK FOR CATV, AND YELLOW FOR CAMERAS. VERIFY ALL REQUIREMENTS WITH OWNER PRIOR TO BID. 12. OUTLET BOXES FOR LIGHTING AND DEVICES SHALL BE MINIMUM REQUIRED BY CODE FOR INSTALLATION SHOWN. 13. WHEN INSTALLING ELECTRICAL OUTLET BOXES IN SHEAR WALLS, CONTRACTOR SHALL CUT APPLICABLE OPENINGS NEATLY AND IN ACCORDANCE WITH MAINTAINING STRUCTURAL, FIRE, AND SOUND RATINGS. r5 14 IN ALL AREAS SPECIFIED BY 210.52 (NEC 2014), ALL NONLOCKING -TYPE 15 AND 20 AMP RECEPTACLES SHALL BE TAMPER-RESISTANT RECEPTACLES. 15. MINIMUM WIRE SIZE FOR A 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE AS FOLLOWS. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FARTHEST OUTLET. ALL WIRE SIZES MAY BE REQUIRED TO BE LARGER DEPENDING ON CONDUIT AND CONDUCTOR ROUTING AND LOAD ON CIRCUIT. #12 FOR LESS THAN 100 FEET. #10 BETWEEN 100 AND 150 FEET. #8 BETWEEN 150 AND 250 FEET FOR ANYTHING OVER 250 FEET. B R R Architect of Record: BRR Architecture, Inc. Kansas City ' 6700 Antioch Plaza Bentonville Suite 300 Phoenix ' Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 • F9133225155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • tl°?. WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL PANELS AND SCHEDULES heet No. E-2 Original printed on recycled paper 5/24/2017 10:01:15 AM STORAGE XC B-13 B-15 WP/GFCI A A0 B-13 B-13 STAIRS. GUEST LAUNDRY I XC B-13 ALL/ V NDING Am B-1. FITNESS 11421 B-13 0A AO,.. B-13 B-13 E A 0 B-13 B-13 ELECTRICAL ROOM MECHANICAL ROOM 11401 QUEEN SUITE QUEEN SUITE 11301 LOBBY REGISTRATION STAFF LAUNDRY DOUBLE --- QUEEN SUITE -DELUXE CORNER SUITE 11141 ADJOINING ROOM 112oI {\ \. / /./ / \ A/ / / j\ c \ ,//.._.: A \ 0B-13 CORRIDOR 1001 ESTIBI -TRAINING ROUTE 1" CONDUIT UNDERGROUND FROM ELECTRICAL ROOM TO BLADE WALL. COORDINATE WITH ARCHITECT FOR FINAL LOCATION. 9 A-39 A-39 QUEEN SUITE 11101 11071 FIRST FLOOR ELECTRICAL PLAN SCALE: 1/8" = 1'-0" MOTORIZED DAMPER: INTERLOCK DAMPER TO OPEN WHEN ANY DRYER IS ON. \ ACC. ..QUEEN /SUITE C-17 C423 '; C-17 C-28 D-13,15 r D-21,23 E D-14 A D-20 D-14 e 1Ai I +48"1 D -3S +367 A D-14 e FSD D-36 D-32 GFCI B-1 A® E D-14 D-14 D-18' AC A D-14& a QUEEN B-24,2 SUITE \ 1 021 D-16 GFCI A® A® 1 D-14 1 D-14 A D-14® a MOUNT ABOVE WASH MACHINE FOR SOAP DISPENSER. VERIFY MOUNTING HEIGHT. A D-14 D-14 p-14 10-11 ;GFCI b-1. GFCIo.:�� D-16 GFCI A& D-14 a A D-140 a NEMA -1 60/2/40 D-10,12 ,4 A D-14 c NEMA -1 30/3/20 OUNT RCPT FOR HEAT RACE AT CEILING. XA ® D-14 A-26,28 A-17,19 D - D-18 WP/GFCI NEMA -1 30/2/15 PLAN KEYNOTES (1 1. 5 TELEPHONE JACKS AND 3 DATA JACKS. TEL#1-FAX, TEL#2-CALL ACCOUNTING, TEL#3-EVENT LOGGER, TEL#4-CREDIT CARD BACKUP, TEL#5-EXT. 355, DATA#1-OFFICE COMPUTER, DATA#2-SECURITY SYSTEM, AND DATA#3-SECURITY MICROPHONE. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. 2. 2 TELEPHONE JACKS AND 2 DATA JACKS. TEL#1-SWITCHBOARD, TEL#2-EXT. 510, DATA#1-INTERNET, AND DATA#2-INTERNET. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. 3. PUSHBUTTON FOR FRONT ENTRY DOORS. 4. PROVIDE CIRCUIT AS SHOWN ON PLANS FOR FRONT DOOR MAG LOCK SYSTEM. COORDINATE ALL REQUIREMENTS WITH MANUFACTURER AND PROVIDE ALL LOW VOLTAGE WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. REFER TO KEYNOTE 3 OFFICE REQUIREMENTS. 5. PROVIDE (2) JUNCTION BOXES. FIRST JUNCTION BOX FOR INTERCOM AND SECOND JUNCTION BOX FOR READER. PROVIDE (1) 3/4" CONDUIT FOR EACH JU TONBSX PTOS 'U TU AN.T 'MN•TEA:sVEC I I G. 6. PROVIDE (1) DATA PORT, (1) GFCI RECEPTACLE, AND (1) WAP. MOUNT ALL ON WALL, REFER TO ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS. REVIEWED .FOR MPLIANCE WITH NFPA 70 tl NEC JUN 3 0 2017 C� Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas (lb/ i 6700 Antioch Plaza Bentonville Suite 300 Phoenix i Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P 913 322 5150 m F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL PLANS - FIRST FLOOR Sheet No. E-3 BRR Original printed on recycled paper 5/24/2017 10:01:18 AM (6D B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix • Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants F A-41 F A-41 ,.. _. F A-41 F A-41 6 Ao As B-12 B-12 XB B-12 DOUBLE QUEEN — SUITE DOUBLE -QUEEN SUITE UTILITY ROOM DOUBLE QUEEN SUITE ............. DOUBLE QUEEN SUITE F 1 221 1 DOUBLE QUEEN \ / SUITE A-41 STAIRS, 12521 1217.1 :\ , A-30 \, " A A 0 B-2 A 0 0B-29 B-12 B-12 „ B-12 F n B-2 0A 0A B-12 1 B-12 DOUBLE' QUEEN \. SUITE /`\ \I2131/7 %' /..\ \ \' B-12<1 F A-41 QUEEN _ SUITE QUEEN SUITE 0 B-12 ACC. —QUEEN-- SUITE DOUBLE QUEEN SUITE DOUBLE QUEEN SUITE DELUXE CORNER SUITE \ /2141 F / XA® \ ."% B-12 B-2 \ // B-12 F A-30 A-41 F A-41 1 212 1 / \. 'QUEEN '\ \SUITE '/ i '\ QUEEN / SUITE F A-30 QUEEN SUITE 12071 F A-30 F A-30 F A-30 i / QUEEN / SUITE \ 1'2041 7 SECOND FLOOR ELECTRICAL PLAN SCALE: 1/8" =1'-0" F A-30 0 A \.., B-12 A0 B-12 A0 XB B-12 B-12 A0 B-12 / A- / / CONSULTING GROUP, LLC 14817 West 951h Street • Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law, Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 / ,•fir n ,y .1,11-001k 1P REVIEWED .FOR COMPLIANCE WITH NFPA 70 a NEC Professional Seal JUN 3 0 2011 JAM 222Mi .. City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 5 2017 PERMIT CENTER EXPIRES: 09/21/17 Sheet Title ELECTRICAL PLANS - SECOND FLOOR Sheet No. E-4 BRR Original printed on recycled paper 5/24/2017 10:01:20 AM B R R Architect of Record: BRR Architecture, Inc. Kansas City Bentonville Phoenix San Francisco Philadelphia Atlanta Miami 6700 Antioch Plaza Suite 300 Merriam, KS 66204 Tel: 913-262-9095 Fax: 913-262-9044 Consultants Ae Ae C-12 C-12 XB C-12 DOUBLE QUEEN SUITE_ ............. DOUBLE QUEEN SUITE, PNLBD'C' C-12 —C C C-12 C-12 UTILITY ROOM DELUXE KING SUITE DOUBLE QUEEN SUITE 13521 FSD C-27 CORRIDOR AC -15 0 A I 1300 I A e C-12 ®F C-1�2 C-12 QUEEN SUITE QUEEN'' SUITE`. .......... ACC. DELUXE KING SUITE 13201 QUEEN\ SUITE \ 1 307 1 SUITE lain) CORRIDOR QUEEN SUITE 1305 1 \ QUEEN SUITE THIRD FLOOR ELECTRICAL PLAN SCALE: 1/8" = 1'-0" C-12 E D Am C-12 Am C-12 ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street 0. Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal JA4 22 291G . JUN 30 2017 City of Tukwila BUILDING DIVISION a.1'�{J1YiTw RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER EXPIRES: 09/21/17 Sheet Title I 1 ELECTRICAL PLANS - THIRD FLOOR Sheet No. E-5 0 BRR Original printed on recycled paper 5/24/2017 10:01:24 AM 1 1 1 1 C-11 UTILITY ROOM DOUBLE-_ QUEEN SUITE DELUXE _ KING C-11 C-11 DP2 C-1311 DOUBLE QUEEN SUITE DOUBLE— QUEEN OUBLE.........QUEEN SUITE -------- DOUBLE QUEEN;__ FAMILY- '\. SUITE. 10 A A® c -i® C-11 \DOUBLE/ QUEEN n C-1 0A C-11 ccORRIDOR A0 A0 6C-15 0A 14001 A0 C-11 C-11 F C-11 C-11 C- E A C-11 lJ C-11 C-11 C-11 0A ® 0 A XA C-11 1 C-11 E 0A C-11 C-11 QUEEN SUITE �434� QUEEN SUITE LG. ACC. DELUXE KING DOUBLE QUEEN SUITE........ DOUBLE QUEEN SUITE 14 a C-11 A-4 \ A0 C-11 L ELEVATOR ELECTRICAL PLAN SCALE: 1/4" = 1'-0" NOTE: COORDINATE FINAL LOCATION AND QUANTITY OF J -BOXES FOR SIGNAGE WITH ARCHITECT AND SIGN VENDOR PRIOR TO ROUGH -IN. ELEVATOR KEYNOTES ( 1 2 x 1. PROVIDE (1) 100A, 3P, 208V BUSSMAN POWER MODULE WITH SHUNT TRIP MECHANISM WITH 70A FUSES FOR ELEVATOR EQUIPMENT PER MANUFACTURER REQUIREMENTS. LOCATE DISCONNECT IN TOP FLOOR UTILITY ROOM AND WIRE ON PRIMARY SIDE OF ELEVATOR MANUFACTURER'S FURNISHED 3 PHASE AUTO TRANSFORMER. COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER. PROVIDE ALL WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. 2. PROVIDE (1) 60A, 3P, 480V FUSED DISCONNECT SWITCH WITH 35A FUSES PER MANUFACTURER REQUIREMENTS. LOCATE DISCONNECT AT TOP OF HOISTWAY AND WIRE ON SECONDARY SIDE OF ELEVATOR MANUFACTURER'S FURNISHED 3 PHASE AUTO TRANSFORMER. COORDINATE ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER. PROVIDE ALL WIRING AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. 3. 20 AMP, 125 VOLT ELECTRICAL CONNECTION AT CONTROLLER LOCATION FOR ELEVATOR CAB POWER (LIGHTING/HVAC). VERIFY ALL REQUIREMENTS WITH ELEVATOR MANUFACTURER PRIOR TO ROUGH -IN. WP J -BOX FOR BUILDING SIGNAGE. ROUTE VIA CONTACTOR. \\CORRIDOR ss„.; \ QUEEN SUITE \ 140\81 C-11 E C-11 QUEEN SUITE ,I)FOURTH FLOOR ELECTRICAL PLAN SCALE: 1/8" = 1'-0" QUEEN SUITE \ QUEEN \SUITE 1'4021 3;)ELECTRICAL ROOF PLAN SCALE: 1/8" = 1'-0" NEMA -3R 60/2/35 NEMA -3R 30/2/20 NEMA -3R 60/2/50 NOTE: COORDINATE FINAL LOCATION AND QUANTITY OF J -BOXES FOR SIGNAGE WITH ARCHITECT AND SIGN VENDOR PRIOR TO ROUGH -IN. A0 XB\ C-11 C-11 t^-11 STAIR, WP J -BOX FOR BUILDING SIGNAGE. ROUTE VIA CONTACTOR. =6 / / klid" JAM 222i. ,f 1'.••r �E!!IEWED .FOR MPLIANCE WITH NFPA 70 - NEC JUN 30 2017 City of .Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY '2 5 2017 PERMIT ENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City i 6700 Antioch Plaza Bentonville Suite 300 Phoenix i Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa. Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 \Osi WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL PLANS — FOURTH FLOOR Sheet No. E-6 0 BRR Original printed on recycled paper 5/24/2017 10:01:30 AM 41) 111 G-7,9 G-1 G-1 GFCI GFCI GFCI A 0-1 b A G-1 0a DISHWASHER El A 00-1 b KITCHEN EXHAUST HOOD 3 4 3 G- 4 KITCHEN 4EXHAUST HOOD KITCHEN EXHAUST HOOD -8,1.0.. GFCI A 00-1 b KITCHEN EXHAUST HOOD 3 © -3 1 4 G-1 DISHWASHER GFCI REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. STUDIO SCALE: 1/4" = 1'-0" G-2 DISHWASHER A G-1 a 'PNLBD 'G' A G -3(S( e w REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. DELUXE STUDIO SCALE: 1/4" = 1'-0" REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. LARGE ACC. DELUXE STUDIO SCALE: 1/4" = 1'-0" REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. STUDIO DOUBLE SCALE: 1/4" = 1'-0" G2-1 ,:::::: G2-1...1.. _1.3 ............... G2-12 A G2-1 r. a A ....... _ G2-1 a G2-1 A G2-1 a • 3 4 KITCHEN EXHAUST HOOD A G2-1 a 021/ 2-6 T\B; DISHWASHER / G2-14 /G2-4' CT \\,/.: G2-12 // // G2-12 /3 G2-12 A0 G2-1 a A 002-1 b G2-12 DISHWASHER /,, 0214 ��/ CT / ,e G2-2 GFCI • .KITCHEN.._ ... EXHAUST HOOD A0 G2-1 a A 0 02-1 a G2-1 j ...B\ CT\' G2-4' -8,10 REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. 02-12 i 0 02-3 A 0 G2-1 a REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. ACC FAMILY SUITE SCALE: 1/4" = 1'-0" MASTER LIGHTING SWITCH G-1 ARCFAULT H CIRCUIT BREAKER N KITCHEN AREA LIGHTS BED AREA LIGHTS NOTE: MASTER LIGHTING SWITCH SHALL DISCONNECT POWER TO ALL ROOM LIGHTING. LABEL SWITCH "MASTER LIGHTING SWITCH". LABEL TO BE PER SPECIFICATION SECTION 16020 PART 8. �2� MASTER LIGHTING SWITCH WIRING DETAIL SCALE: NOT TO SCALE PNLBD 'G2'. REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS, COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. / 1 FAMILY SUITE SCALE: 1/4" = 1'-0" G2-12 GFCI `0..5. G4 0-11 0-6 T G810 A 0-1 a DISHWASHER G-1 KITCHEN EXHAUST HOOD 3 4 A ' -10 a �\ PNLBD 'G' LARGE ACC STUDIO DOUBLE SCALE: 1/4" = 1'-0" TELEPHONE BOARD ROOM DATA PUNCH DOWN BOARD REFER TO ARCHITECTURAL ELEVATIONS FOR ALL LOCATIONS AND MOUNTING HEIGHTS. VERIFY ALL REQUIREMENTS. DO NOT DIMENSION FROM THESE PLANS. COORDINATE ALL CEILING LIGHT FIXTURE LOCATIONS WITH OWNER AND ARCHITECTURAL PLANS PRIOR TO ROUGH -IN, SWITCH LIGHTS ONLY. C OS,3 B-13 Br 8,10 Pp -AC -3 C B-13 6 ACC STUDIO Vy SCALE: 1/4" = 1'-0" MDP DP1 jB-23 B-22 4l) B-21 B-19 30/3/240 DISC. SW. & NEMA "0" STARTER FUSE AS REQUIRED. FOR BOOSTER PUMPS. G-1 A G-30„... e CORNER STUDIO SCALE: 1/4" = 1'-0" A-33,35,37 A-27,29,31 CLOCK DIRECT TV RACK TERM. BOARD INTERNET & CAMERA RACK BOARD C C B-13 B-13 B-30,32 A-10 A-12 A-14 WH -1 WH -2 WH -3 1. =1 -o JAM 22 2t1, ENLARGED PLAN KEYNOTES GFCI REVIEWED FOR MPLIANCE WITH NFPA70 - NEC JUN 3 0 2017 DEVICES TO BE GANGED TOGETHER. MOUNT AT HEIGHT INDICATED ON ARCHITECTURAL PLANS. 0 AL L 'I P• , mAT•, L CONNECTION TO FURNITURE EQUIPMENT. H'0 SK D AK 3. SUITE ANNUNCIATOR REQUIRED IN HEARING IMPAIRED SUITES ONLY. PORTABLE WIRELESS SYSTEM FOR HEARING IMPAIRED SUITES (DOOR BELL SYSTEM) SYSTEM AVAILABLE AT THE FRONT DEST. PROVIDE QUANTITY OF SYSTEMS SHOWN ON LIFE SAFETY DRAWINGS. 4. CONTRACTOR SHALL CONTACT LOCAL TELEPHONE PROVIDER TO OBTAIN REQUIREMENTS FOR HEARING IMPAIRED ROOMS. CONTRACTOR SHALL THEN INSTALL ALL REQUIRED EQUIPMENT. 5. ALL GUESTROOM 120V RECEPTACLES SHALL BE TAMPER-RESISTANT SPECIFICATION GRADE RECEPTACLES AS REQUIRED BY N.E.C. 6. PROVIDE 2-3" CONDUIT WITH PULLWIRE FOR CABLE TV AND TELEPHONE. ROUTE UNDERGROUND AND STUB OUT 5'-0" FROM BUILDING. CAP AND MARK FOR OWNER USE. 7. PROVIDE 1-1 1/2" AND 1-2" CONDUIT FOR CAMERA AND CATV CABLING. ROUTE FROM OPENING AND STUB INTO FIRST FLOOR CORRIDOR CEILING CAVITY. 8. PROVIDE 1-3" CONDUIT WITH PULLWIRE FOR FUTURE USE. ROUTE UNDERGROUND AND STUB OUT 5'-0" FROM BUILDING. CAP AND MARK FOR OWNER USE. RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Phliadeiphia manta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P 913 322 5150 G F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal ---- EXPIRES: 09/21/17 Sheet Title ELECTRICAL ENLARGED PLANS Sheet No. E-7 0 BRR Original printed on recycled paper 5/24/2017 10:01:36 AM FIRE ALARM 4TH FLOOR SCALE: 1/16" = 1'-0" FIRE ALARM GENERAL NOTES 1. VERIFY ALL OUTLET LOCATIONS ON THE JOB PRIOR TO ROUGH -IN. 2. REFER TO RELATED ARCHITECTURAL, MECHNICAL, AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION. 3. REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. 4. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING OF BRICK BLOCK. 5. ALL MOUNTING HEIGHTS TO BOTTOM OF ITEM UNLESS NOTED OTHERWISE. 6. WHERE AREA SMOKE DETECTORS ARE SHOWN ON THE DRAWINGS ELECTRICAL CONTRACTOR SHALL NOT LOCATE SMOKE DETECTORS CLOSER THAN 3 FEET FROM ANY MECHANICAL AIR SUPPLY OR RETURN DIFFUSER, GRILLE, OR REGISTER PER NFPA. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR LOCATION OF DETECTOR. 7. ALL FIRE ALARM DEVICE LOCATIONS AND DETAILS ARE FOR REFERENCE ONLY. LOCAL GOVERNING CODES AND REQUIREMENTS SHALL TAKE PREFERENCE OVER ALL DETAILS FOR LOCATIONS AND MOUNTING HEIGHTS. VERIFY LOCAL GOVERNING CODES AND REQUIREMENTS WITH LOCAL INSPECTION DEPARTMENT PRIOR TO BID. COMPLETE FIRE ALARM SYSTEM, INSTALLATION AND OPERATION SHALL MEET THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. ALL INITIATING DEVICES MUST BE ADDRESSABLE. "STAND ALONE" DEVICES WILL NOT BE ALLOWED UNLESS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 8. HEARING IMPAIRED SUITES REQUIRE ADDITIONAL STROBE LIGHTS, FIELD VERIFY ROOMS THAT REQUIRE ADDITIONAL STROBES. STROBES SHALL BE LOCATED AS REQUIRED BY NATIONAL, STATE, AND LOCAL ORDINANCES. HEARING IMPAIRED ROOM NUMBERS ARE 124, 125, 126, 224, 225, 226, 324, 325, 326, 415, 417, 425, AND 426. 9. ADA ROOMS ARE 121, 123, 215, 217, 315, 317, AND 417. 10. ALL AUDIO DEVICES WITHIN SLEEPING AREAS SHALL PRODUCE A 520 HZ, LOW -FREQUENCY SIGNAL PER N.F.P.A. 72. 11. ALL WALL MOUNTED VISIBLE NOTIFICATION APPLIANCES, LOCATED IN SLEEPING AREAS, SHALL BE NO CLOSER THAN 24" TO THE CEILING AND HAVE A CANDELA RATING NO LESS THAN 110cd. APPLIANCES MOUNTED ON THE WALL CLOSER THAN 24" TO THE CEILING OR ON THE CEILING SHALL HAVE A CANDELA RATING NOT LESS THAN 177cd PER N.F.P.A. 72. 12. ALL NOTIFICATION APPLIANCES SHALL BE WHITE IN COLOR. FIRE ALARM SYMBOL LIST FIRE ALARM MATRIX OUTPUTS ACTUATE COMMON ALARM SIGNAL LAMP ACTUATE COMMON SUPERVISORY SIGNAL LAMP ACTUATE COMMON TROUBLE SIGNAL LAMP ACTUATE PIEZO - FACP \ANNUNCIATOR ACTUATE AUDIO\VISUAL DEVICES - GENERAL ALARM ACTUATE FIRE\SMOKE DAMPERS BY LOCATION ACTUATE SMOKE RELIEF DAMPER TOP OF ELEVATOR SHAFT SHUTDOWN AIR HANDLER EQUIPMENT WITH ASSOCIATED DUCT DETECTOR UNLOCK ACCESS CONTROLLED DOORS RELEASE ELECTROMAGNETICALLY CLOSED DOORS RECALL ELEVATOR TO PRIMARY RECALL FLOOR RECALL ELEVATOR TO ALTERNATE RECALL FLOOR ACTIVATE ELEVATOR WARNING LIGHTS ACTIVATE ELEVATOR SHUNT TRIP I TRANSMIT SIGNAL TO CENTRAL STATION VERIFY INPUTS RESIDENT ROOM SMOKE DETECTOR AND SOUNDER BASE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 COMMON AREA MANUAL PULL BOX A 0 0000 00 0 A SMOKE DETECTOR B 0 0000 00 0 B HEAT DETECTOR C 0 0000 00 0 C DUCT DETECTOR D 0 0 00 0 D ELEVATOR ELEVATOR LOBBY SMOKE - NOT FLOOR 1 E 0 0000 000 0E ELEVATOR LOBBY SMOKE - FLOOR 1 F 0 0000 00 0 0 F SMOKE DETECTOR ELEVATOR MACHINE ROOM G 0 0000 000 0 0 G HEAT DETECTOR ELEVATOR MACHINE ROOM H 0 0000 00 80 H SMOKE DETECTOR ELEVATOR PIT I 0 0000 00 00 0 I HEAT DETECTOR ELEVATOR PIT J 0 0000 00 00 J SMOKE DETECTOR ELEVATOR TOP OF SHAFT K 0 8000 000 0 0 K HEAT DETECTOR ELEVATOR TOP OF SHAFT L 0 0000 00 00 L FLOW SWITCH ELEVATOR MACHINE ROOM M 0 0000 00 00 M TAMPER SWITCH ELEVATOR MACHINE ROOM N 0 0 0 0 N FLOW SWITCH TOP OF SHAFT 0 0 0000 00 00 0 TAMPER SWITCH TOP OF SHAFT P 0 0 0 P FIRE SPRINKLER FIRE PUMP RUN Q 0 0 0 Q FIRE PUMP PHASE REVERSAL R 0 0 0 R FIRE PUMP PHASE FAIL S 0 0 0 S FLOW SWITCH T 0 0 0 0 0 0 0 T TAMPER SWITCH U 0 0 0 U DRY SYSTEM LOW HI\LOW V 0 0 0 V HEAT TRACE FAULT W 0 0 0 W SYSTEM SYSTEM ALARM X 0 000 00 x SYSTEM SUPERVISORY Y 0 0 Y SYSTEM TROUBLE Z 00 Z GROUND FAULT AA 00 AA FIRE ALARM SYSTEM LOW BATTERY BB 0 0 BB FIRE ALARM AC POWER FAILURE CC 00 CC NOTIFICATION APPLIANCE SHORT CIRCUIT DD 00 DD OPEN CIRCUIT EE 00 EE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 FIRE ALARM 4TH FLOOR SCALE: 1/16" = 1'-0" FIRE ALARM GENERAL NOTES 1. VERIFY ALL OUTLET LOCATIONS ON THE JOB PRIOR TO ROUGH -IN. 2. REFER TO RELATED ARCHITECTURAL, MECHNICAL, AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION. 3. REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. 4. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO MINIMIZE CUTTING OF BRICK BLOCK. 5. ALL MOUNTING HEIGHTS TO BOTTOM OF ITEM UNLESS NOTED OTHERWISE. 6. WHERE AREA SMOKE DETECTORS ARE SHOWN ON THE DRAWINGS ELECTRICAL CONTRACTOR SHALL NOT LOCATE SMOKE DETECTORS CLOSER THAN 3 FEET FROM ANY MECHANICAL AIR SUPPLY OR RETURN DIFFUSER, GRILLE, OR REGISTER PER NFPA. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR LOCATION OF DETECTOR. 7. ALL FIRE ALARM DEVICE LOCATIONS AND DETAILS ARE FOR REFERENCE ONLY. LOCAL GOVERNING CODES AND REQUIREMENTS SHALL TAKE PREFERENCE OVER ALL DETAILS FOR LOCATIONS AND MOUNTING HEIGHTS. VERIFY LOCAL GOVERNING CODES AND REQUIREMENTS WITH LOCAL INSPECTION DEPARTMENT PRIOR TO BID. COMPLETE FIRE ALARM SYSTEM, INSTALLATION AND OPERATION SHALL MEET THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. ALL INITIATING DEVICES MUST BE ADDRESSABLE. "STAND ALONE" DEVICES WILL NOT BE ALLOWED UNLESS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 8. HEARING IMPAIRED SUITES REQUIRE ADDITIONAL STROBE LIGHTS, FIELD VERIFY ROOMS THAT REQUIRE ADDITIONAL STROBES. STROBES SHALL BE LOCATED AS REQUIRED BY NATIONAL, STATE, AND LOCAL ORDINANCES. HEARING IMPAIRED ROOM NUMBERS ARE 124, 125, 126, 224, 225, 226, 324, 325, 326, 415, 417, 425, AND 426. 9. ADA ROOMS ARE 121, 123, 215, 217, 315, 317, AND 417. 10. ALL AUDIO DEVICES WITHIN SLEEPING AREAS SHALL PRODUCE A 520 HZ, LOW -FREQUENCY SIGNAL PER N.F.P.A. 72. 11. ALL WALL MOUNTED VISIBLE NOTIFICATION APPLIANCES, LOCATED IN SLEEPING AREAS, SHALL BE NO CLOSER THAN 24" TO THE CEILING AND HAVE A CANDELA RATING NO LESS THAN 110cd. APPLIANCES MOUNTED ON THE WALL CLOSER THAN 24" TO THE CEILING OR ON THE CEILING SHALL HAVE A CANDELA RATING NOT LESS THAN 177cd PER N.F.P.A. 72. 12. ALL NOTIFICATION APPLIANCES SHALL BE WHITE IN COLOR. FIRE ALARM SYMBOL LIST SYMBOL DESCRIPTION MOUNTING P FIRE ALARM MANUAL PULL STATION 4'-0" TO TOP K1 COMBINATION F.A. HORN & STROBE SIGNAL WALL 80" A.F.F. IO FIRE ALARM STROBE SIGNAL WALL 80" A.F.F. 0 AREA SMOKE DETECTOR, SEE F.A. GENERAL NOTE #6 CEIL./WALL FIRE ALARM MAGNETIC DOOR HOLD OPEN (HOLD OPEN) VERIFY 0. R RESIDENT ROOM SMOKE DETECTOR AND SOUNDER BASE CEIL./WALL 0 AREA HEAT DETECTOR CEIL./WALL l< HEARING IMPAIRED HORN & STROBE SIGNAL WALL 80" A.F.F. FIRE ALARM 2ND FLOOR (TYPICAL FOR 3RD FLOOR) SCALE: 1/16" = 1'-0" CANDELA RATING IN SLEEPING AREAS <24" FROM CEILING 177cd 2224" FROM CEILING 110cd JUN 3 0 2017 CEILING MOUNTED SMOKE/HEAT DETECTOR CEILING 6" MIN. 24" MIN. X HANDICAP BEDROOM STROBE AUDIO ONLY DEVICE N.F.P.A. 72 3' MINIMUM //)iL/////\\\\\r////////// NC SUPPLY DIFFUSER N.F.P.A. 72 NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST OF THE DETECTOR LINE 2 CAT5 CABLE AUDIONISUAL AND VISUAL -ONLY DEVICES FACP W/ DACT SYNCHRONIZE MORE— THAN TWO APPLIANCES IN ANY FIELD OF VIEW N.F.P.A. 72 DOOR WIDTH LESS 3" WALL MOUNTED SMOKE/HEAT DETECTOR FINISHED WALL FIRE ALARM ANNUNCIATOR PANEL PHONE LINE SURGE PROTECTOR I—RJ-31X JACK TO TELEPHONE MOUNTING BOARD 1 PAIR TELCO PHONE LINE SURGE PROTECTOR I—RJ-31X JACK PROVIDE CONNECTION TO SPRINKLER SYSTEM FLOW AND TAMPER SWITCHES AND DRY PIPE SYSTEM AIR COMPRESSOR. VERIFY LOCATION AND REQUIREMENTS. TO TELEPHONE MOUNTING BOARD FIRE ALARM CONTROL PANEL WITH ANNUNCIATOR LINE 1 120 VOLT AC CAT5 CABLE 1 PAIR TELCO 90" MIN. TO TOP OF DEVICE N.F.P.A. 72 80" MIN. 96" MAX TO BOTTOM OF LENS N.F.P.A. 72 MAGNETIC DOOR HOLDER MANUAL PULL STATION SIDE WALL FIRE ALARM 1ST FLOOR SCALE: 1/16" = 1'-0" Jai' 22 2 t FINISHED FLOOR NOT TO EXCEED 5'-0" RECEIVED CITY OF TUKWILA i5� DEVICE MOUNTING HEIGHTS SCALE: NOT TO SCALE MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas Qty Bentonville Phoenlx San Francisco Philadelphia Atlanta Miami 6700 Antioch Plaza Suite 300 Merriam, KS 66204 Tel: 913-262-9095 Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a speciflc site contemporaneously with its Issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title FIRE ALARM SYSTEM PLANS Sheet No. E-8 0 BRR Original printed on recycled paper 5/24/2017 10:01:39 AM BOND SYSTEM GROUND TO GROUNDING LUG INSIDE POLE BOLT COVER HAND HOLE AND COVER LEVELING NUT GENERAL NOTES GROUT UNDER POLE 1" CHAMFER 1. VERIFY PAD LOCATION, DIMENSIONS AND ALL REQUIREMENTS WITH LOCAL UTILITY CO. OPENINGS ARE BASED ON ABBB & GE TRANSFORMERS. CHECK WITH LOCAL UTILITY CO. PRIOR TO CONSTRUCTION OF PAD. 2. THE TOP OF THE TRANSFORMER PAD SHALL RECIEVE A SMOOTH TROWEL FINISH. THE CORNERS AND EDGES SHALL BE ROUNDED OR BEVELLED. 3. IF THE TRANSOFRMER PAD IS INSTALLED IN AN AREA SUBJECT TO VEHICULAR TRAFFIC, THE INSTALLATION SHALL BE PROTECTED PER UTILITY CO. STANDARDS. 4. THE CONDUIT OPENING SHALL BE FREE AND CLEAR OF CONCRETE. SITE LIGHT FIXTURE SCHEDULE FIXT LTR MANUFACTURER CATALOG NUMBER LAMPS FIXT VOLT FINISH MOUNTING TOTAL VA. REMARKS NO. TYPE SA1 CLI NAWS-T2-48LC-7-4K-UNV-BOA... - , LED W/ UNIT 120 BRONZE 25' POLE 228 SITE LIGHTING HEAD SA2 CLI NAWS-T2-48LC-7-4K-UNV-BOA... - LED W/ UNIT 120 BRONZE 25' POLE 456 DOUBLE SITE LIGHTING HEAD SA3 CLI NAWS-T2-48LC-7-4K-UNV-BOA... - LED W/ UNIT 120 BRONZE 25' POLE 456 90 DEGREE DOUBLE SITE LIGHTING HEAD 5. THE MAXIMUM NUMBER OF CONDUITS ON SECONDARY SERVICE SHALL NOT EXCEED THE MAXIMUM NUMBER ALLOWED BY THE UTILITY CO. VERIFY WITH UTILITY CO. PRIOR TO ROUGH -IN. 6. PROVIDE PROPER CLEARANCE AROUND TRANSFORMER FROM ANY ABOVE GROUND OBSTRUCTIONS. VERIFY REQUIREMENTS WITH LOCAL UTILITY CO. AND AHJ. FINISHED GRADE OR PARKING LOT SURFACE LIGHT FIXTURE SCHEDULE NOTES 1. VERIFY LAMP COLOR WITH ARCHITECT PRIOR TO ORDERING. 2. MANUFACTURERS LISTED IN THIS SCHEDULE OR BY WRITTEN ADDENDUM WILL BE THE ONLY APPROVED MANUFACTURERS TO BID THE LIGHTING FIXTURES FOR THIS PROJECT. CONTRACTORS AND SUPPLIERS USING PRICING FROM MANUFACTURERS NOT LISTED ON SCHEDULE OR BY ADDENDUM DO SO AT THEIR OWN RISK. 3. FIXTURES BY THE FOLLOWING MANUFACTURERS EQUAL TO THOSE SPECIFIED AND APPROVED BY THE ENGINEER WILL BE ACCEPTABLE: FIXTURE EQUALS SHALL BE MANUFACTURED THE SAME AS SPECIFIED UNITS, I.E., ENCLOSED SPRING LOADED LATCHES, ALUMINUM DOORS, POST PAINTED FINISH. 4. PROVIDE POLE AS NOTED. POLE TYPE AND EXACT SPEC MUST MEET ALL CODE REQUIREMENTS FOR LOCAL WIND LOAD CATEGORY. ANCHOR BOLTS BY POLE MANUFACTURER COORDINATE STRUCTURAL REQUIREMENTS OF POLE BASE WITH STRUCTURAL ENGINEER CONDUIT SIZE AS SHOWN ON DRAWING GALVANIZED ANCHOR BOLTS BY POLE MANUFACURER PER MANUFACTURER'S BOLT CIRCLE 24" DIA. VERIFY WITH SITE POLE POLE ROUND OR SQUARE AS INDICATED BY FIXT. SCHEDULE POLE BASE DETAIL SCALE: NOT TO SCALE VERIFY ALL PRIMARY AND SECONDARY ELECTRICAL SERVICE ENTRANCE REQUIREMENTS WITH LOCAL UTILITY CO. CODES AND ORDINANCES PRIOR TO BID. INCLUDE ALL ASSOCIATED COSTS IN BID. PROVIDE AND INSTALL (2) 3" CONDUITS FROM BUILDING TO PROPERTY LINE AS REQUIRED. ONE FOR TELEPHONE SERVICE AND ONE FOR CATV SERVICE. VERIFY ROUTING AND REQUIREMENTS WITH LOCAL SERVICE PROVIDERS PRIOR TO ROUGH -IN. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. REFER TO SECOND FLOOR ELECTRICAL PLAN ON SHEET E- 4 FOR BUILDING MOUNTED LIGHT FIXTURE LOCATIONS AND DESIGNATIONS. NEW UTILITY CO. PAD MOUNTED TRANSFORMER AND METER. 4" SCH. 40 PVC CONDUIT WITH STEEL ELLS AND RISERS, MIN. 48" BELOW GRADE WITH PULLWIRE FOR PRIMARY CONDUCTORS. VERIFY ALL REQUIREMENTS WITH SERVING UTILITY AND CIVIL ENGINEER PRIOR TO ROUGH -IN. NEW SECONDARY ELECTRICAL SERVICE ENTRACE CONDUCTORS. SEE ELECTRICAL RISER DIAGRAM. REVIEWED .FOR t MPLIANCE WITH NFPA 70 - NEC JUN 3 0 2017 ELECTRICAL ROOM SA2 A-30 047-1 PYLON SIGN NOTES: �y 1. CONTRACTOR TO PROVIDE AND INSTALL AL, CONDUIT, WIRE, AND DEVICES REQUIRED F4''. MONUMENT SIGN. VERIFY LOCATION AND REQUIREMENTS WITH SIGN MANUFACTUR PRIOR TO ROUGH -IN. 2. SIGN LOCATION UNDETERMINED AT TIME OF DESING. CONTRACTOR TO VERIFY EXACT LOCATION PRIOR TO BID. 3. PROVIDE GROUNDING AND BONDING PER MANUFACTURER'S (WATCHFIRE) AND LOCAL REQUIREMENTS. B R R Architect of Record: BRR Architecture, Inc. Kansas city 6700 Antioch Plaza Bentonville Suite 300 Phoenix . Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street 0 Lenexa, Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway —Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal A-38 A-40 A-42 SITE PLAN SCALE: 1" = 20'-0" 3/4" CONDUIT FOR CIRCUIT TO CONTROL SIGN LIGHTING. REFERENCE EXTERIOR LIGHTING CONTROL DETAIL ON SHEET E-2. COORDINATE WITH SIGN VENDOR AND VERIFY WHICH CIRCUITS NEED TO BE CONTROLLED BY LIGHTING CONTACTOR. (TYPICAL OF 6) PYLON SIGN N.>„,,A-21 A-23 A-25 PYLON SIGN" RECEIVED CITY OF TUKWILA MAY 252017 P4 IT .. EXPIRES: 09/21/17 Sheet Title ELECTRICAL SITE PLAN Sheet No. E-9 BRR Original printed on recycled paper 5/24/2017 10:01:40 AM ENERAL ELECTRICAL NOTES ART 1 - GENERAL EXTENT OF WORK .1 THE GENERAL CONDITIONS, GENERAL REQUIREMENTS, AND SPECIAL CONDITIONS SHALL BE AND ARE HEREBY MADE A PART OF THIS SECTION. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, TRANSPORTATION, EQUIPMENT, SERVICES AND FACILITIES REQUIRED FOR THE COMPLETE, PROPER AND SUBSTANTIAL INSTALLATION OF ALL ELECTRICAL WORK SHOWN ON THE DRAWINGS AND/OR OUTLINED IN THESE SPECIFICATIONS. THE INSTALLATION SHALL INCLUDE ALL MATERIALS, APPLIANCES AND APPARATUS NOT SPECIFICALLY MENTIONED HEREIN OR NOTED ON THE DRAWINGS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION OF ALL ELECTRICAL SYSTEMS. .2 THE CONTRACTOR SHALL CONSULT AND BE GUIDED BY THE GENERAL CONDITIONS AND ALL OTHER DIVISIONS REFERRED TO HEREIN AND RELATIVE THERETO IN PERFORMING THE WORK COVERED UNDER THIS DIVISION OF THE SPECIFICATION. 3 ALL OF THE ELECTRICAL RELATED WORK REQUIRED FOR THIS PROJECT (UNLESS SPECIFIED OTHERWISE) ISA PART OF THE ELECTRICAL CONTRACT PRICE AND IS NOT NECESSARILY SPECIFIED UNDER THIS DIVISION OF THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS. THEREFORE, ALL DIVISIONS OF THE SPECIFICATIONS AND ALL DRAWINGS SHALL BE CONSULTED. 4 THE DRAWINGS SHOWING THE LAYOUT OF THE WORK INDICATE THE APPROXIMATE LOCATIONS OF OUTLETS, APPARATUS AND EQUIPMENT. THE DRAWINGS ARE SCHEMATIC ONLY AND ARE NOT INTENDED TO SHOW THE EXACT ROUTING OF CONDUITS, ETC. THE FINAL DETERMINATION AS TO THE ROUTING SHALL BE GOVERNED BY STRUCTURAL CONDITIONS AND OTHER OBSTRUCTIONS. THIS SHALL NOT BE CONSTRUED TO MEAN THE DESIGN OF THE SYSTEM MAY BE CHANGED, IT MERELY REFERS TO THE EXACT RUN OF A RACEWAY BETWEEN GIVEN POINTS. THE CONTRACTOR SHALL CONSULT ALL CONTRACT DRAWINGS WHICH MAY AFFECT THE LOCATION OF ANY OUTLET, APPARATUS OR EQUIPMENT TO AVOID POSSIBLE INTERFERENCE AND PERMIT FULL COORDINATION OF ALL WORK. THE RIGHT TO MAKE ANY REASONABLE CHANGE IN THE LOCATION OF APPARATUS, OUTLETS AND EQUIPMENT UP TO THE TIME OF ROUGHING -IN IS RESERVED BY THE ARCHITECT WITHOUT INVOLVING ANY ADDITIONAL EXPENSE TO THE OWNER. 5 THE APPROVAL BY THE ARCHITECT OR HIS REPRESENTATIVE OF ANY MATERIALS, DRAWINGS, ETC., SUBMITTED BY THE CONTRACTOR WILL BE CONSIDERED AS GENERAL ONLY AND TO AID THE CONTRACTOR IN CARRYING OUT HIS WORK. SUCH APPROVAL AS MAY BE GIVEN DOES NOT RELIEVE THE CONTRACTOR FROM THE NECESSITY OF FURNISHING THE MATERIALS AND PERFORMING ALL THE WORK AS REQUIRED BY THE DRAWINGS AND THE SPECIFICATIONS. .6 THE WORK SPECIFIED UNDER THIS DIVISION OF THE SPECIFICATIONS SHALL INCLUDE THE FURNISHING OF ALL LABOR, MATERIALS, APPARATUS AND TOOLS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL CONDUIT AND WIRING; DEVICES FOR LIGHTING, POWER AND CONTROL SYSTEMS, AND SUCH OTHER WORK AND EQUIPMENT AS ARE INDICATED ON THE DRAWINGS OR AS NOTED HEREIN. .7 THE ENTIRE INSTALLATION SHALL BE MADE IN A WORKMAN LIKE MANNER, LEFT COMPLETELY CONNECTED, AND READY TO GIVE PROPER AND CONTINUOUS SERVICE. .8 ALL MATERIALS AND WORK IN CONNECTION WITH THE FOREGOING ITEMS SHALL BE AS SPECIFIED HEREIN, OR CALLED FOR ON THE DRAWINGS. .9 THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE NATIONAL FIRE PROTECTION ASSOCIATION AND ALL OTHER BOARDS AND DEPARTMENTS HAVING JURISDICTION. ANY ITEMS OR REQUIREMENTS NOTED HEREIN OR SHOWN ON THE DRAWINGS IN EXCESS OF CODE REQUIREMENTS, BUT PERMITTED UNDER THE CODE, SHALL TAKE PREFERENCE UNLESS SPECIAL PERMISSION IS OBTAINED FROM THE ARCHITECT TO THE CONTRARY. .10 THE LIGHT AND POWER INSTALLATION SHALL OPERATE WITH THE ELECTRICAL ENERGY OBTAINED FROM OUTSIDE SOURCES. SUCH PART OF THE SYSTEM AS MAY BE REGULATED BY RULES OF THE LOCAL UTILITY COMPANY SHALL, INSOFAR AS METHOD OF CONSTRUCTION, WORKMANSHIP AND MATERIALS ARE CONCERNED, BE IN FULL ACCORDANCE WITH THE STANDARD PRACTICE AND RULES AND REGULATIONS OF THE LOCAL UTILITY COMPANY. .11 THIS CONTRACTOR SHALL COORDINATE HIS WORK UNDER THIS DIVISION OF THE SPECIFICATIONS WITH THE WORK OF OTHER TRADES WHEREIN IT MAY BE INTERRELATED. HIS WORK SHALL BE DONE IN SUCH AN ORDER THAT THERE WILL BE NO INTERFERENCE IN INSTALLING, NOR DELAY IN COMPLETION, OF ANY PART OR PARTS OF EACH RESPECTIVE TRADE, THEREBY PERMITTING ALL CONSTRUCTION WORK TO PROCEED IN ITS NATURAL SEQUENCE WITHOUT UNNECESSARY DELAY. .12 BEFORE SUBMITTING HIS BID, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE RULES OF ALL GOVERNING BODIES HAVING JURISDICTION AND SHALL NOTIFY THE ARCHITECT IN SUBMITTING HIS BID, IF IN HIS OPINION, ANY WORK OR MATERIAL SPECIFIED IS CONTRARY TO SUCH RULES. OTHERWISE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE APPROVAL OF ALL WORK AND MATERIALS AND, IN CASE THE USE OF ANY MATERIAL SPECIFIED IS NOT PERMITTED, A SUBSTITUTE SHALL BE APPROVED BY THE ARCHITECT AND SHALL BE PROVIDED AT NO INCREASE IN COST. .13 UNLESS NOTED OTHERWISE ON THE DRAWINGS, OR ELSEWHERE IN THESE SPECIFICATIONS, THE SINGULAR WORDS 'PROVIDE', 'FURNISH', OR 'INSTALL' NOTED ON THE DRAWINGS OR IN THESE SPECIFICATIONS SHALL MEAN TO COMPLETELY FURNISH, INSTALL, AND CONNECT EACH ITEM, AND IF SUCH IS A PART OR COMPONENT OF A SYSTEM THE ENTIRE SYSTEM SHALL BE FUNCTIONAL WITH ALL ITEMS AND COMPONENTS PROVIDED. ART 2 - RULES AND REGULATIONS .1 ALL WORK UNDER THIS HEADING SHALL COMPLY WITH THE LATEST RULES AND REGULATIONS OF THE NATIONAL ELECTRICAL CODE STANDARD OF THE NATIONAL FIRE PROTECTION ASSOCIATION AND WITH ALL LAWS, REGULATIONS AND ORDINANCES OF THE UTILITY COMPANY, CITY, COUNTY AND STATE. 2 DRAWINGS AND SPECIFICATIONS INDICATE THE MINIMUM STANDARDS OF CONSTRUCTION. SHOULD ANY WORK INDICATED BE SUBSTANDARD TO ANY ORDINANCE, LAW, CODE, RULE OR REGULATION BEARING ON WORK, THE CONTRACTOR SHALL EXECUTE WORK ACCORDINGLY, WITHOUT INCREASED COST TO THE OWNER, BUT NOT UNTIL HE HAS REFERRED SUCH VARIANCES TO THE ARCHITECT FOR HIS APPROVAL. 3 THIS CONTRACTOR SHALL PROVIDE AND INSTALL ONLY THE BRANDS OF MATERIALS AND EQUIPMENT SPECIFIED HEREIN, OR EQUIPMENT APPROVED BY THE ARCHITECT -ENGINEER AS EQUAL. ALL MATERIAL AND EQUIPMENT SHALL BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES, INC., INDICATING COMPLIANCE WITH NATIONALLY RECOGNIZED STANDARDS AND/OR TESTS. ART 3 - PERMITS, FEES AND INSPECTIONS 1 SECURE AND PAY FOR ALL NECESSARY AND USUAL PERMITS, FEES, INSPECTIONS AND CERTIFICATES REQUIRED FOR THIS WORK AND DELIVER PERMITS AND CERTIFICATES TO THE ARCHITECT FOR TRANSMITTAL TO THE OWNER BEFORE FINAL ACCEPTANCE OF THE PROJECT. ART 4 - SERVICES .1 THIS CONTRACTOR SHALL PAY FOR ALL EXPENSES, DEPOSITS, REIMBURSEMENTS, ETC., REQUIRED BY THE LOCAL RULES AND CODES FOR THE SERVICE TO THE BUILDING, COMPLETE AND READY FOR USE. 2 THIS CONTRACTOR SHALL BEAR ALL EXPENSES INVOLVED FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL SERVICE (BOTH TEMPORARY AND PERMANENT) TO THE BUILDING READY FOR OPERATION, EXCEPT AS SPECIFICALLY EXCLUDED ON THE DRAWINGS. ALL TEMPORARY WIRING SHALL BE INSTALLED PER THE NATIONAL ELECTRICAL CODE. THIS SHALL INCLUDE GUARD POSTS AROUND TRANSFORMERS AND PEDESTALS PER UTILITY COMPANY STANDARDS. VERIFY COMPLETE INSTALLATION AND LOCATIONS OF PAD MOUNT OR POLE MOUNT TRANSFORMERS WITH THE LOCAL ELECTRIC UTILITY COMPANY AND BID INSTALLATION TO COMPLY WITH THEIR REQUIREMENTS. 3 THIS CONTRACTOR SHALL CONSULT ALL LOCAL DEPARTMENTS TO VERIFY REQUIREMENTS AND BID INSTALLATION OF SERVICE IN ACCORDANCE WITH LOCAL CODES AND UTILITY COMPANY STANDARDS. .4 THIS CONTRACTOR SHALL BEAR ALL EXPENSES INVOLVED FOR THE COMPLETE TELEPHONE SERVICE CONDUIT INSTALLATION AND STEEL OR NYLON PULL WIRE READY FOR CABLE INSTALLATION. VERIFY COMPLETE INSTALLATION WITH THE LOCAL TELEPHONE COMPANY AND BID INSTALLATION TO COMPLY WITH THEIR REQUIREMENTS. ART 5 - TEMPORARY ELECTRICAL 1 ELECTRICAL CONTRACTOR/SUBCONTRACTOR SHALL: A. MAKE ARRANGEMENTS WITH ELECTRIC UTILITY FOR TEMPORARY SERVICE. B. PROVIDE MATERIALS, EQUIPMENT, LABOR TO INSTALL, MODIFY, MAINTAIN (AND UPON COMPLETION OF PROJECT, REMOVE) SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING SYSTEMS PER OSHA STANDARDS. C. PROVIDE SUFFICIENT CAPACITY FOR CONSTRUCTION TOOLS, EQUIPMENT, TEMPORARY VENTILATION AND LIGHTING. D. DISTRIBUTE SYSTEMS THROUGHOUT BUILDING AND CONSTRUCTION AREA OF SITE SUCH THAT AN EXTENSION CORD NO LONGER THAN 100' WILL REACH ANY WORK AREA. OPEN BRANCH SYSTEMS PERMITTED WHERE PERMITTED BY THE NATIONAL ELECTRICAL CODE AND OSHA. PROVIDE TEMPORARY SERVICES TO ALL CONSTRUCTION OFFICES AS REQUIRED. E. EMPLOY PERMANENT SYSTEMS AS THEY ARE COMPLETED AND AVAILABLE. F. PROVIDE METERING OF TEMPORARY SERVICE. ALL TEMPORARY UTILITY COSTS WILL BE PAID BY THE GENERAL CONTRACTOR. ART 6 - MATERIALS OF APPROVED EQUAL .1 WHERE ITEMS OF EQUIPMENT AND/OR MATERIALS ARE SPECIFICALLY IDENTIFIED HEREIN BY A MANUFACTURER'S NAME, MODEL OR CATALOG NUMBER, ONLY SUCH SPECIFIC ITEMS MAY BE USED IN THE BASE BID, EXCEPT AS HEREINAFTER PROVIDED. .2 UNLESS REQUESTS FOR CHANGES IN BASE BID SPECIFICATIONS ARE RECEIVED AND APPROVED AND NOTED BY WRITTEN ADDENDUM PRIOR TO THE OPENING OF BIDS, THE SUCCESSFUL CONTRACTOR WILL BE HELD TO FURNISH SPECIFIED ITEMS. .3 AFTER CONTRACT IS AWARDED, CHANGES IN SPECIFICATIONS SHALL BE MADE ONLY AS DEFINED UNDER "SUBSTITUTION OF EQUIPMENT." ART 7 - SUBSTITUTION OF EQUIPMENT .1 AFTER EXECUTION OF THE CONTRACT, NO SUBSTITUTION OF EQUIPMENT WILL BE ALLOWED. .2 REQUESTS FOR SUBSTITUTIONS MUST BE ACCOMPANIED BY DOCUMENTARY PROOF OF EQUALITY OF DIFFERENCE IN PRICE AND DELIVERY, IF ANY, IN FORM OF CERTIFIED QUOTATIONS FROM SUPPLIERS OF BOTH SPECIFIED AND PROPOSED EQUIPMENT. .3 THE OWNER SHALL RECEIVE ALL BENEFITS OF THE DIFFERENCE IN COST INVOLVED IN ANY SUBSTITUTION, AND THE CONTRACT ALTERED BY CHANGE ORDER TO CREDIT OWNER WITH ANY SAVINGS SO OBTAINED. ART 8 - COORDINATION AND BUILDING CONDITIONS .1 THE CONTRACTOR SHALL VISIT THE SITE AND DETERMINE ALL EXISTING LOCAL CONDITIONS AFFECTING WORK IN HIS CONTRACT. HE SHALL EXAMINE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS TO FAMILIARIZE HIMSELF WITH THE TYPE OF CONSTRUCTION TO BE USED FOR ALL WORK AND HOW IT WILL AFFECT THE INSTALLATION OF WORK IN HIS CONTRACT. .2 FAILURE TO DETERMINE EXISTING CONDITIONS OR THE NATURE OF EXISTING OR NEW CONSTRUCTION WILL NOT BE CONSIDERED AS A BASIS FOR THE GRANTING OF ADDITIONAL COMPENSATION. .3 THE DRAWINGS HAVE BEEN PREPARED TO COVER ALL ELECTRICAL WORK UNDER THIS CONTRACT. THE CONTRACTOR IS REFERRED TO ALL OTHER CONTRACT DRAWINGS TO GUIDE HIM IN THE PROPER INSTALLATION OF HIS WORK. .4 THE CONTRACTOR SHALL FULLY FAMILIARIZE HIMSELF WITH THE FLOOR DRAWINGS, ELEVATIONS, DETAILS OF CONSTRUCTION, FEEDERS, FIXTURES, CONDUIT, WIRING, SERVICE, ETC., INSOFAR AS IT MAY AFFECT THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION IN ORDER THAT ALL NECESSARY MATERIALS AND LABOR MAY BE PROVIDED EVEN THOUGH NOT SPECIFICALLY REFERRED TO ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS. .5 AS THE DRAWINGS ARE GENERALLY DIAGRAMMATIC, THE FINAL LAYOUT OF THE WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT BUT THE CONTRACTOR SHALL BE RESPONSIBLE WITHOUT INCREASE IN CONTRACT PRICE FOR THE COORDINATION OF ALL WORK UNDER VARIOUS DIVISIONS OF THE SPECIFICATIONS. .6 THIS CONTRACTOR SHALL CONFER WITH OTHER CONTRACTORS INSTALLING WORK WHICH MAY AFFECT HIS WORK AND MUST ARRANGE HIS CONDUIT, ETC., IN PROPER RELATION TO SUCH WORK. ANY DAMAGE RESULTING FROM HIS NEGLECT TO DO SO MUST BE PAID FOR BY THE CONTRACTOR. .7 WHERE NECESSARY TO FIT AND CENTER WITH PANELING OF CEILINGS AND WALL SPACES, THE CONTRACTOR MUST, AT HIS OWN EXPENSE, SHIFT THE LIGHTING OUTLETS OR OTHER OUTLETS AS REQUIRED BY THE ARCHITECT. .8 ALL OUTLETS SHALL BE SET IN SUCH A MANNER AS TO FINISH FLUSH WITH WALL AND CEILING LINES UNLESS MARKED TO BE EXPOSED OR SURFACE MOUNTED ON THE DRAWINGS. THE HEIGHT OF BRACKETS, SWITCHES, OUTLETS, ETC., ARE TO BE AS DIRECTED. 9 THE CONTRACTOR SHALL OBTAIN FROM THE ARCHITECTURAL AND STRUCTURAL DRAWINGS THE EXACT LOCATION AND SIZE OF SPACES AVAILABLE FOR HIS APPARATUS AND MATERIAL AND SHALL INSTALL THEM ACCORDINGLY. IN CASE THE SPACE ALLOWED IS NOT SUFFICIENT, OR AN OBSTRUCTION INTERFERES WITH PLACING THEM AS SHOWN OR SPECIFIED, THE CONTRACTOR SHALL OBTAIN INSTRUCTIONS FROM THE ARCHITECT AND SHALL INSTALL THEM AS DIRECTED WITHOUT EXTRA CHARGE. .10 THE ABOVE PROVISIONS REFER ONLY TO THE EXACTNESS OF POSITIONS THAT CANNOT BE DETERMINED FROM THE DRAWINGS AND DO NOT PERMIT PLACING APPARATUS DISTINCTLY DIFFERENT FROM THAT SHOWN ON THE DRAWINGS. .11 THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING OF BUILDING MATERIALS REQUIRED FOR THE INSTALLATION OF WORK HEREIN SPECIFIED. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT AND ALL SUCH CUTTING SHALL BE DONE IN A MANNER DIRECTED BY HIM. .12 ALL PATCHING SHALL BE DONE IN A NEAT AND WORKMAN -LIKE MANNER, MEETING WITH THE APPROVAL OF THE ARCHITECT, BY MECHANICS OF THE PARTICULAR TRADE INVOLVED. .13 ANY HOLES OR VOIDS CREATED IN FLOORS, CEILINGS AND WALLS, INCLUDING ANY SPACES OR GAPS AROUND CONDUIT OR EQUIPMENT PASSING THROUGH SUCH AREAS, WHICH COMPROMISE THE APPLICABLE RATING OF THE FLOORS, CEILINGS OR WALLS, SHALL BE SEALED WITH AN INTUMESCENT MATERIAL CONFORMING TO ARCHITECTURAL REQUIREMENTS. ALL INSTALLATIONS SHALL BE PER MANUFACTURER'S EXACT INSTRUCTIONS. .14 ALL DRILLING OF HOLES THROUGH CONCRETE SHALL BE ACCURATELY AND CAREFULLY DONE BY USING A POWERED CONCRETE DRILL. THE USE OF A STAR DRILL OR AIR HAMMER FOR THIS WORK SHALL NOT BE PERMITTED. .15 ALL PAINTING SHALL BE PERFORMED IN ACCORDANCE WITH THE ARCHITECTURAL SPECIFICATION SECTION ON "PAINTING AND FINISHING". ALL COLORS AND FINISH APPLICATIONS SHALL BE AS DIRECTED BY THE ARCHITECT. (PAINTING IS NOT REQUIRED OF RECEPTACLES, SWITCHES, CIRCUIT BREAKERS, ETC., UNLESS SPECIFICALLY SO NOTED ON THE DRAWINGS.) .16 THE ELECTRICAL CONTRACTOR SHALL CONFIRM THE EXACT ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT SUPPLIED BY OTHERS AND INSTALLED OR CONNECTED BY THE ELECTRICAL CONTRACTOR. THE SPECIFIC WORK PERFORMED FOR THE INSTALLATION OF ANY EQUIPMENT SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS ESTABLISHED BY THE SHOP DRAWINGS OF THE EQUIPMENT SUPPLIED. IN THE EVENT THE SHOP DRAWINGS ESTABLISH REQUIREMENTS DISTINCTLY DIFFERENT THAN THE REQUIREMENTS SHOWN IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE ENTITLED ONLY TO AN ADJUSTMENT OF THE DIFFERENCE BETWEEN THE WORK SHOWN AND THE WORK REQUIRED WITH FULL CREDIT FOR LABOR AND MATERIALS SHOWN ON THE ORIGINAL DRAWINGS. .17 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TRENCHING AND BACKFILLING FOR UNDERGROUND CONDUITS. UNLESS NOTED OTHERWISE IN OTHER DIVISIONS OF THESE SPECIFICATIONS, ALL TRENCHES SHALL BE BACKFILLED AND COMPACTED WITH MATERIAL DEFINED BY THE UNITED SOIL CLASSIFICATION AS ML OR CL (SILT AND CLAY OF LOW TO MEDIUM PLASTICITY). COMPACTION SHALL BE TO 90% OF ASTM D698. PART9-PERFORMANCE 9.1 PROVIDE AS PART OF THE WORK OF THIS CONTRACT, IN ADDITION TO THE FIRST YEAR GUARANTEE ON EQUIPMENT AND MATERIALS, THE FOLLOWING DESCRIBED ROUTINE MAINTENANCE AND INSPECTION. (THE ONE YEAR TIME PERIOD WILL NOT START UNTIL EACH AND EVERY ITEM IS COMPLETE IN ACCORDANCE WTH DRAWINGS AND SPECIFICATIONS AND ACCEPTED BY THE OWNER). CHECK ALL EMERGENCY SYSTEMS, CONTROL, FIRE ALARM, TRANSFORMERS, ETC., CORRECT AND ADJUST SAME. THIS SERVICE TO BE PROVIDED DURING THE GUARANTEE PERIOD. PART 10 - ADJUSTING, ALIGNING AND TESTING 10.1 ALL EQUIPMENT SHALL BE CHECKED FOR PROPER ADJUSTMENT AND BALANCE. ALL PANELBOARDS, DISTRIBUTION PANELS, SWITCHBOARDS, AND TRANSFORMERS SHALL BE BALANCED TO PROVIDE A BALANCED LOAD ON EACH PHASE. A COMPLETE RECORD OF ALL SUCH ADJUSTMENTS SHALL BE MADE. FINAL READINGS SHALL BE SUBMITTED TO THE ARCHITECT -ENGINEER FOR RECORDS. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, INSTRUMENTS, GAUGES, METERS, ETC., AS REQUIRED FOR THE COMPLETE CHECKING OF THESE SYSTEMS. 10.2 MECHANISMS OF ALL ELECTRICAL EQUIPMENT SHALL BE CHECKED, ADJUSTED, AND TESTED FOR PROPER OPERATION. ADJUSTABLE PARTS OF ALL LIGHTING FIXTURES AND OTHER ELECTRICAL EQUIPMENT SHALL BE CHECKED, ADJUSTED, AND TESTED AS REQUIRED TO PRODUCE THE INTENDED PERFORMANCE. 10.3 COMPLETED WIRING SYSTEM SHALL BE FREE FROM OPEN OR SHORTED CIRCUITS. AFTER COMPLETION, THIS CONTRACTOR SHALL PERFORM TESTS FOR INSULATION RESISTANCE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. 10.4 THE CONTRACTOR SHALL MAINTAIN SERVICE AND EQUIPMENT FOR THE TESTING OF ELECTRICAL EQUIPMENT AND APPARATUS UNTIL ALL WORK IS APPROVED AND ACCEPTED BY THE OWNER. A FIRST CLASS VOLTMETER AND AMMETER SHALL BE KEPT AVAILABLE AT ALL TIMES AND THIS CONTRACTOR SHALL PROVIDE SERVICE FOR TEST READINGS WHEN AND AS REQUIRED. ALL TEST READINGS SHALL BE RECORDED ON AN APPROVED FORM AND SUBMITTED TO THE ARCHITECT. 10.5 BEFORE FINAL ACCEPTANCE IS MADE, THIS CONTRACTOR SHALL, AT HIS OWN EXPENSE, FRAME UNDER PLASTIC THE SEQUENCE OF OPERATIONS OF THE SOUND SYSTEM, CONTROLS, FIRE ALARM, ETC., FOR EACH AND EVERY ITEM REQUIRING INSTRUCTIONS. THESE INSTRUCTIONS SHALL BE MOUNTED AS DIRECTED. HE SHALL COVER SAME WITH ARCHITECT AND/OR HIS SELECTED PARTIES, AND SHALL ADJUST ALL APPARATUS AND PLACE SAME IN SATISFACTORY OPERATING SERVICE AS APPROVED BY THE ARCHTECT. 10.6 FINAL OBSERVATION WILL BE MADE UPON WRITTEN REQUEST FROM THE CONTRACTOR AFTER THE PROJECT IS COMPLETE. AT THE TIME OF FINAL OBSERVATION, THE CONTRACTOR SHALL BE PRESENT OR SHALL BE REPRESENTED BY A PERSON OF AUTHORITY. THE CONTRACTOR SHALL DEMONSTRATE, AS DIRECTED BY THE ARCHITECT -ENGINEER, THAT HIS WORK FULLY COMPLIES WITH THE PURPOSE AND INTENT OF THE DRAWINGS AND SPECIFICATIONS. ALL LABOR, SERVICES, AND ALL INSTRUMENTS OR TOOLS NECESSARY FOR SUCH DEMONSTRATION AND TESTS SHALL BE PROVIDED BY THE CONTRACTOR. PART 11 - MOTOR CONTROL AND SPECIAL CONNECTIONS 11.1 THE ELECTRICAL CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT ALL WIRING, CONDUIT, BOXES, TOGGLE SWITCHES,THERMAL SWITCHES, DISCONNECT SWITCHES, REMOTE PUSH-BUTTON STATIONS NOT INCLUDED IN MAGNETIC STARTERS, ETC., FOR ALL EQUIPMENT REQUIRING ELECTRICAL POWER THAT IS FURNISHED BY OTHER CONTRACTORS AND/OR THE OWNER, AS REQUIRED FOR A COMPLETE AND OPERATABLE SYSTEM. THE ELECTRICAL CONTRACTOR SHALL RECEIVE, INSTALL AND CONNECT ALL MAGVETIC STARTERS AND CONTROLLERS, CAPACITORS, POWER FACTOR CORRECTION DEVICES, TRANSFORMERS, ALARMS, BELLS, HORNS, RELAYS, REMOTE SWITCHES, ETC., FOR EQUIPMENT SUPPLIED BY OTHERS, (I.E. STARTERS, CAPACITORS OR POWER FACTOR CORRECTION DEVICES FOR MECHANICAL EQUIPMENT, ETC.). IN GENERAL ALL MAJOR EQUIPMENT WILL BE SPECIFIED TO BE FACTORY PREWIRED WITH ONLY SERVICE AND INTERLOCKING REQUIRED AT THE SITE BY THE ELECTRICAL CONTRACTOR; HOWEVER HE SHALL CHECK ALL DIVISIONS OF THE SPECIFICATIONS TO VERIFY IF THE EQUIPMENT IS SPECIFIED FACTORY PREWIRED AND IF NOT, THEN IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE THE COMPLETE WIRING OF THE EQUIPMENT IN ACCORDANCE WITH WIRING DIAGRAMS, AND TEMPERATURE CONTROL DRAWINGS PROVIDED BY THE OTHER CONTRACTORS AND/OR THE OWNER, TO THE ELECTRICAL CONTRACTOR. PLL INTERLOCKING OF EQUIPMENT SHALL BE BY THE ELECTRICAL CONTRACTOR. 11.2 ALL CONTROL EQUIPMENT REQUIRING PIPING CONNECTIONS TO AIR, WATER, STEAM, ETC., LINES SUCH AS PNEUMATIC ELECTRICAL RELAYS, REMOTE BULB TEMPERATURE CONTROLS, SOLENOID VALVES, AQUASTATS, PRESSURE CONTROL, ETC., WILL BE FURNISHED AND INSTALLED UNDER "MECHANICAL WORK". 11.3 ALL LINE AND LOW VOLTAGE WIRING, CONDUIT AND CONNECTIONS REQUIRED TO CONTROL EQUIPMENT AND/OR DAMPERS ARE A PART OF THIS SECTION. PROVIDE AND INSTALL LINE OR LOW VOLTAGE WIRING TO ALL DAMPERS AS REQUIRED FOR SYSTEM OPERATION. ALL LOW VOLTAGE WIRING, CONDUIT, CONNECTIONS AND/OR TERMINATIONS ARE BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE WITHIN THE BIDDING DOCUMENTS. 11.4 IT SHALL BE ASSUMED THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE EQUIPMENT TO BE FURNISHED BY THE OTHER CONTRACTORS AND/OR THE OWNER IN CONNECTION WITH THIS WORK AND THAT PROVISIONS FOR SUCH CONNECTIONS AND WORK HAVE BEEN INCLUDED IN THE CONTRACTOR'S PRICE. IN NO CASE WILL EXTRA REMUNERATION BE ALLOWED FOR SUCH WORK. 11.5 CONNECTIONS TO ALL EQUIPMENT HAVE BEEN DESIGNED FOR UNITS AS SPECIFIED ON THE DRAWINGS OR IN THE SPECIFICATIONS. IN THE EVENT EQUIPMENT OR CONTROLS DIFFER ON APPROVED MECHANICAL SHOP DRAWINGS, IT SHALL BE THE RESPONSIBILITY OF THE SUPPLYING CONTRACTOR TO COORDINATE ELECTRICAL CONNECTIONS TO THE UNITS AND REIMBURSE ELECTRICAL CONTRACTOR FOR ANY CHANGES IN SYSTEM DESIGN. THESE CHANGES SHALL NOT INVOLVE ADDITIONAL COST TO THE OWNER. PART 12 - GUARANTEE 12.1 THIS CONTRACTOR, BY THE ACCEPTANCE OF THIS SPECIFICATION AND THE SIGNING OF HIS CONTRACT, ACKNOWLEDGES HIS ACQUAINTANCE WITH THE REQUIREMENTS AND GUARANTEES THAT EVERY PART USED IN CONSTRUCTING THE SYSTEM AS HEREIN DESCRIBED WILL BE OF THE BEST OF ITS RESPECTIVE KIND THAT CAN BE OBTAINED AND WILL BE ERECTED IN A MOST THOROUGH AND SUBSTANTIAL MANNER BY NONE BUT EXPERIENCED WORKMEN. 12.2 HE GUARANTEES THAT ALL CONDUIT AS PROVIDED WITHIN AND BY THIS SPECIFICATION WILL BE FREE FROM ALL OBSTRUCTIONS OF EVERY DESCRIPTION AND WILL BE FREE FROM HOLES OR BROKEN PLACES AND BE WELL BONDED TOGETHER. HE GUARANTEES THAT ALL WIRING AND CONDUIT TO BE USED IN CONSTRUCTION OF THIS PROJECT WILL BE NEW AND UNUSED. 12.3 HE FURTHER GUARANTEES TO HOLD HIMSELF RESPONSIBLE FOR ANY DEFECTS WHICH MAY DEVELOP IN ANY PART OF THE ENTIRE SYSTEM, INCLUDING APPARATUS AND APPLIANCES PROVIDED UNDER THIS SECTION OF THE SPECIFICATION, AND TO REPLACE AND MAKE GOOD WITHOUT COST TO THE OWNER ANY SUCH FAULTY PARTS OF CONSTRUCTION WHICH DEVELOP DEFECTS AT ANY TIME WITHIN ONE YEAR FROM DATE OF FINAL CERTIFICATION OF COMPLETION AND ACCEPTANCE. PROVIDE MANUFACTURER'S ENGINEERING AND TECHNICAL STAFF AT SITE TO ANALYZE AND RECTIFY PROBLEMS THAT DEVELOP DURING GUARANTEE PERIOD IMMEDIATELY. IF PROBLEMS CANNOT BE RECTIFIED IMMEDIATELY TO THE OWNER'S SATISFACTION, ADVISE ARCHITECT IN WRITING, DESCRIBE EFFORTS TO RECTIFY SITUATION, AND PROVIDE ANALYSIS OF CAUSE OF PROBLEM. ARCHITECT WILL THEN SUGGEST COURSE OF ACTION. THE ELECTRICAL CONTRACTOR SHALL REPLACE MATERIAL AND EQUIPMENT THAT REQUIRES EXCESSIVE SERVICE DURING GUARANTEE PERIOD AS DEFINED AND AS DIRECTED BY THE ARCHITECT. THIS GUARANTEE DOES NOT INCLUDE ORDINARY LAMP FAILURE. 12.4 USE OF SYSTEMS PROVIDED UNDER THE SPECIFICATION FOR TEMPORARY SERVICES AND FACILITIES SHALL NOT CONSTITUTE FINAL ACCEPTANCE OF THE WORK NOR BENEFICIAL USE BY THE OWNER, AND SHALL NOT INSTITUTE GUARANTEE PERIOD. PART 13 - SUPPLEMENTARY CONDITIONS 13.1 SUPPLEMENTARY TO ALL OTHER TERMS OF THE CONTRACT, THIS WORK SHALL BE PERFORMED SUBJECT TO THE FOLLOWING CONDITIONS. 13.2 MATERIALS AND EQUIPMENT INSTALLED ON THIS PROJECT SHALL BE FIRST CLASS IN QUALITY AND SHALL BE NEW AND UNUSED. 13.3 WORKMANSHIP ON THIS PROJECT SHALL BE FIRST CLASS WORK PERFORMED BY THE EXPERIENCED LICENSED MECHANICS OF THE PROPER TRADE. 13.4 WORK UNDER THIS CONTRACT SHALL BE ADEQUATELY PROTECTED AT ALL TIMES. TEMPORARY RACEWAYS SHALL BE KEPT CLOSED AND ALL RACEWAYS SHALL BE INSTALLED CLEAN AND FREE FROM DIRT AND GREASE. 13.5 STORAGE, PARKING, SIGNS, ADVERTISEMENT, FIRES AND SMOKING SHALL CONFORM TO ALL APPLICABLE REGULATIONS AND/OR DIRECTIONS OF THE ARCHITECT. 13.6 MEASUREMENTS ON JOB AND SHOP LAYOUTS REQUIRED FOR INSTALLATION OF WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND ACCEPTANCE OF WORK IS SUBJECT TO APPROVAL OF SHOP DRAWINGS BY THE ARCHITECT. 13.7 CONTRACTOR SHALL FURNISH ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS AND EQUIPMENT NECESSARY FOR THE COMPLETION OF THIS WORK. 13.8 OBTAIN AND PAY FOR ALL REQUIRED ELECTRICAL PERMITS AND LICENSES. 13.9 MAINTAIN LIGHTS AND GUARDS REQUIRED FOR SAFETY. 13.10 REMOVE TEMPORARY SERVICE AFTER USE. PART 14 - CONTRACT CHANGES 14.1 ALL CHANGES OR DEVIATIONS FROM THE CONTRACT, INCLUDING THOSE FOR EXTRA OR ADDITIONAL WORK, MUST BE SUBMTTED IN WRITING FOR THE APPROVAL OF THE ARCHITECT/ENGINEER. NO VERBAL ORDERS WILL BE RECOGNIZED. PART 15 - RUBBISH/CLEANUP 15.1 ALL RUBBISH RESULTING FROM THE WORK HEREIN SPECIFIED SHALL BE PERIODICALLY REMOVED BY THIS CONTRACTOR. 15.2 CLEAN ALL ELECTRICAL EQUIPMENT AND MATERIALS OF ALL FOREIGN MATTER (BOTH INSIDE AND OUT). CLEAN ALL LIGHT FXTURES USING ONLY METHODS AND MATERIALS AS RECOMMENDED BY THE MANUFACTURER. PART 16 - PROPOSALS 16.1 THE CONTRACTOR SHALL CONSULT THE GENERAL CONDITIONS AND THE PROPOSAL FORM FOR PROPOSALS AND SUBDIVISIONS OF THE WORK REQUIRED. PART 17 - EXTENT OF WORK 17.1 THE EXTENT OF THE WORK UNDER THIS HEADING OF THE CONTRACT SHALL BE THE FURNISHING OF ALL PLANT, LABOR, MATERIALS, AND EQUIPMENT AS REQUIRED TO COMPLETE WORK AS SHOWN ON THE DRAWINGS AND AS SPECIFIED UNDER THIS HEADING, AND ALL PLANT, LABOR, MATERIALS AND EQUIPMENT NOT SHOWN ON THE DRAWINGS OR SPECIFIED, BUT NECESSARY TO MAKE INSTALLATION COMPLETE IN ACCORDANCE WITH THE INTENT OF THE CONTRACT, TO PROVIDE FIRST CLASS, COMPLETE, AND OPERATIVE INSTALLATION THROUGHOUT. PART 18 - TAXES 18.1 CONTRACTOR SHALL INCLUDE ALL APPLICABLE LOCAL, STATE AND FEDERAL TAXES IN HIS BID. CONSULT THE SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS RELATIVE TO ANY AND ALL TAX EXEMPTIONS PERMITTED FOR THIS PROJECT. END OF SECTION COMMUNICATION SYSTEMS PART 1 -GENERAL 1.1 SUMMARY A. SCOPE: EXTENT OF COMMUNICATIONS SYSTEMS WORK IS INDICATED BY DRAWINGS AND DETAILS, AND AS HEREBY DEFINED TO INCLUDE, BUT NOT BE LIMITED TO TELEPHONE, DATA, AND CCTV (SECURITY CAMERAS) CONDUITS, CABLES, BOXES, JACKS, TERMINALS, AND OTHER ASSOCIATED EQUIPMENT AND HARDWARE, AND CATV CONDUITS, BOXES, TERMINALS, AND OTHER ASSOCIATED EQUIPMENT AND HARDWARE. THERE ARE OBLIGATIONS THAT REST WITH AT LEAST THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR, OWNER'S TELECOM VENDOR, AND THE OWNER. B. PROVIDE SUBMITTALS ON ALL PRODUCTS SPECIFIED WITH THIS SECTION. C. ALL TELEPHONE, DATA, CATV, AND CCTV CABLING, ASSOCIATED CONDUITS, TERMINATIONS, AND INTERFLOOR SLEEVES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR (EC). D. ALL TELEPHONE AND DATA RACKS, PATCH PANELS, AND WIRE MANAGEMENT HARDWARE WILL BE FURNISHED AND INSTALLED BY OWNER'S TELECOM VENDOR, UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. ALL TELEPHONE AND DATA JACKS WILL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. CATV GUEST ROOM TERMINATIONS TO BE DONE BY CONTRACTOR. CONTRACTOR SHALL PROVIDE ALL FINAL CONNECTIONS TO DEVICES AND PROVIDE FINAL TESTING OF CABLES. E. CATV PATCH PANELS, RACKS, EQUIPMENT, ETC. WILL BE PROVIDED AND INSTALLED BY THE OWNER'S INSTALLERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. 1.2 QUALITY ASSURANCE A. CODES AND STANDARDS: CONFORM TO THE FOLLOWING: a. NATIONAL ELECTRICAL CODE (NEC): COMPLY WITH APPLICABLE LOCAL CODE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND NEC. b. EIA/TIA TSB -40 STANDARD. c. EIA/TIA-568B STANDARD. d. ALL WIRING SHALL BE INSTALLED USING 'BICSI' CABLING PRACTICES. e. THIS INSTALLATION MUST BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL SYSTEM SUPPLIER AND THE GENERAL SPECIFICATIONS CONTAINED HEREIN. CONSULT THE SERVING INSTALLERS TO VERIFY ALL REQUIREMENTS. PART2-PRODUCTS 2.1 TELEPHONE AND DATA SYSTEM 2.1.1 GENERAL CONTRACTOR SHALL PROVIDE TELEPHONE, DATA, AND CATV TERMINAL BOARD(S) AS SHOWN ON THE DRAWINGS BOARD SHALL BE 3/4" FIRE RESISTANT PLYWOOD MOUNTED AND SIZED AS SHOWN ON DRAWING E-5 DRAWINGS G, J, AND L. TERMINAL BOARD TO BE SECURELY MOUNTED ON WALL AND PAINTED WITH TWO COATS OF FIRE RETARDANT NON-CONDUCTIVE PAINT, COLOR AS SELECTED BY ARCHITECT. GENERAL CONTRACTOR TO CONFIRM OWNER'S ROOM NUMBERING SCHEME WHICH IS THEN TO BE USED BY THE ELECTRICAL CONTRACTOR AND OWNER'S TELECOM VENDOR FOR LABELING PURPOSES. 2.1.2 ELECTRICAL CONTRACTOR SHALL PROVIDE: A. ENTRANCE CONDUIT: THERE SHALL BE PROVIDED A 3" MINIMUM MAIN SERVICE CONDUIT FROM BELOW THE TELEPHONE TERMINAL BOARD TO THE PROPERTY LINE (UNLESS A LARGER SIZE IS NOTED OTHERWISE ON THE DRAWINGS OR REQUIRED BY THE TELEPHONE COMPANY. CONDUIT SIZING AND ROUTING TO BE PER THE REQUIREMENTS OF THE SERVING TELEPHONE COMPANY. B. OUTLETS: ALL TELEPHONE AND DATA OUTLET BOXES SHALL BE FURNISHED AND INSTALLED WITH 4" SQUARE, MINIMUM 2 1/8" DEEP BOX AND TRIM. ALL TELEPHONE AND DATA OUTLET BOXES TO BE LOCATED AS SPECIFIED ON PRINTS. EACH TELEPHONE, DATA, CCTV, AND CATV OUTLET BOX SHALL BE PROVIDED WITH ONE (1)'/4" STEEL FLEXIBLE TO NEAREST ACCESSIBLE CORRIDOR CEILING CAVITY. PVC FLEXIBLE CONDUIT MAY BE USED IF ALLOWABLE BY LOCAL CODES. ALL TELEPHONE, DATA, AND CATV BOXES IN ROOMS SHALL BE THEIR OWN BOX AND NOT SHARED WITH ANY ELECTRICAL BOXES. TELEPHONE AND DATA OUTLET BOXES NOT USED SHALL BE PROVIDED WITH BLANK COVER PLATES TO MATCH SWITCH AND RECEPTACLE PLATES. C. DROPS: EACH TELEPHONE AND DATA OUTLET BOX LOCATION REQUIRES TELEPHONE AND DATA CABLES TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. TELEPHONE AND DATA CABLES SHALL BE ROUTED TO THE TELEPHONE TERMINAL BOARD OR DATA TERMINAL BOARD AS APPROPRIATE. VERIFY LOCATION AND CONDITIONS OF JOB PRIOR TO ROUGH -IN. THERE ARE SPECIAL REQUIREMENTS FOR THE TELEPHONE CABLES SERVICING THE ELEVATOR CONTROL CABINET AND THE FIRE ALARM CONTROL PANEL AND FOR THE SURVEILLANCE CAMERAS AS INDICATED IN THE ELECTRICAL NOTES ON SHEET E-5 D. CABLE: TELEPHONE, DATA, AND CCTV CABLE (FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR) SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: a. TELEPHONE CABLES SHALL BE ROUTED TO THE TELEPHONE TERMINAL BOARDS, DATA CABLES SHALL BE ROUTED TO THE DATA TERMINAL BOARDS AND CATV CABLES SHALL BE ROUTED TO THE CATV TERMINAL BOARD. SEE DRAWING E-5, DRAWINGS G, J, AND L. ALL TERMINATIONS AT MAIN DISTRIBUTING FRAME (MDF) PUNCH -DOWN BLOCKS AND DATA PATCH PANELS TO BE DONE BY OWNER'S TELECOM VENDOR. b. ALL TELEPHONE CABLES SHALL BE LEVEL CAT 5E CABLE OR BETTER AND JACKETED IN WHITE. ALL DATA CABLES SHALL BE LEVEL CAT5E CABLE OR BETTER AND JACKETED IN BLUE. CCTV DATA CABLES TO BE LEVEL CAT -5E OR BETTER AND JACKETED IN YELLOW. VERIFY EXACT TYPE OF CABLE WITH OWNER PRIOR TO INSTALLATION. CABLES SHALL BE PLENUM RATED IF ROUTED IN AIR PLENUM CEILING VOIDS. c. CABLES SHALL BE CONTINUOUS WITHOUT SPLICES OR DAMAGE FROM OUTLET TO APPROPRIATE TERMINAL BOARD IN ELECTRICAL ROOM 145. d. EACH CABLE TO UNDERGO SYSTEMS TESTING BY CONTRACTOR. ELECTRICAL CONTRACTOR TO REPLACE CABLES DETERMINED TO BE UNACCEPTABLE. e. ALL CABLES SHALL BE IDENTIFIED ON BOTH ENDS WITH PERMANENT, DURABLE, LEGIBLE, LABELS. LABEL CABLES AT CEILING OF ELECTRICAL ROOM 145 WHERE CABLES ENTER ROOM. LEAVE 25' OF EXTRA CABLE COILED AND PROTECTED FROM DAMAGE AT THE APPROPRIATE TERMINAL BOARD. LABEL THIS SLACK WITH OWNER'S NUMBERING SYSTEM. AT EACH OUTLET, LEAVE 18" OF SLACK CABLE AT CONNECTION TO DEVICE. LABEL THIS SLACK WITH OWNER'S NUMBERING SYSTEM ON ALL OUTLETS IN THE OFFICE AREAS. E. DO NOT ROUTE TELEPHONE OR DATA CABLE BESIDE ELECTRICAL POWER CONDUITS. LOCATE AS FAR AWAY AS REASONABLY POSSIBLE. MINIMUM REQUIREMENTS ARE 5" FROM LIGHTING FIXTURES AND 4" FROM ELECTRICAL CONDUITS. ANYTIME CABLES ARE REQUIRED TO CROSS ELECTRICAL CONDUITS, CABLES SHALL BE ROUTED AT 90 DEGREE ANGLE ONLY TO CONDUITS. MAXIMUM RUN FOR ANY CABLE FROM TELEPHONE OR DATA OUTLET TO TERMINAL BOARD SHALL BE 295'. CONDUIT RUNS SHALL NOT EXCEED 100' BETWEEN PULL BOXES. NO MORE THAN (2) 90 DEGREE BENDS SHALL BE ALLOWED BETWEEN PULL BOXES. a. PROVIDE DOUBLE DUPLEX RECEPTACLE ON SEPARATE 20 AMP CIRCUITS BENEATH EACH TELEPHONE TERMINAL BOARD, DATA TERMINAL BOARD, AND CATV TERMINAL BOARD LOCATION. b. THERE IS TO BE A #6 AWG STRANDED COPPER WIRE EXTENDED FROM THE GROUND BUS IN THE ELECTRICAL PANEL BOARD TO A COMMON GROUNDING BLOCK ON THE TERMINAL BOARD. 2.1.3 ELECTRICAL CONTRACTOR: A. FURNISH AND INSTALL NECESSARY WALL MOUNTED DATA RELAY RACK, PATCH JACKS, AND WIRE MANAGEMENT HARDWARE WITHIN THE RACK TO TERMINATE THE DATA "DROP" RUNNING CABLES . PROVIDE AND INSTALL THE BACKBOARDS, WIRE MANAGEMENT HARDWARE, AND TERMINAL BLOCKS TO TERMINATE THE TELEPHONE "DROP" RUNNING CABLES FOR USE AS A MAIN DISTRIBUTING FRAME (MDF) FOR THE HOUSE WIRING AND PBX CABLING. B. FURNISH AND INSTALL EACH TELEPHONE/DATA OUTLET SHALL BE PROVIDED WITH A TELEPHONE JACK AND A DATA JACK. JACKS SHALL CONSIST OF A "RJ11" (COLORED "IVORY") SINGLE PORT INSERT FOR TELEPHONE OUTLET AND A "RJ45" (COLORED BLUE) SINGLE PORT "KEYSTONE FORMAT" INSERTS FOR DATA OUTLET. "RJ11" PORT INSERT SHALL BE TO USOC RJ -14 WIRING. "RJ45" PORT"KEYSTONE FORMAT" INSERT SHALL BE UNIVERSAL T568 B WIRING. PROVIDE SINGLE GANG FACEPLATE AND BLANK INSERTS AS REQUIRED. C. FURNISH AND INSTALL APPROPRIATE CABLE ENDS ON CCTV DROPS AT EACH CAMERA LOCATION. D. ALL WIRING SHALL BE INSTALLED USING TIA/EIA AND 'BICS' CABLING PRACTICES. WHERE CONNECTIONS OCCUR, UNTWISTING OF CABLE SHALL BE WITHIN EIA/TIATSB-40 STANDARD. FINAL CONNECTIONS OF CABLES AT PATCH PANELS, THE MDF AND FIELD DEVICES WILL BE BY THE OWNER'S TELECOM VENDOR. E. OWNER'S TELECOM TO ROUTE, AND SECURE ALL TELEPHONE AND DATA "DROPS" TO THE WALL OR OTHER SUPPORTING STRUCTURE IN THE ELECTRICAL ROOM 145 SO AS TO FORM THEM INTO THE APPROPRIATE TERMINAL BOARD AND DESTINATION TERMINALS. F. OWNER'S TELECOM VENDOR TO DRESS IN AND TERMINATE ALL TELEPHONE AND DATA CABLES USING THE APPROPRIATE WIRING STANDARDS. ALL TERMINATIONS TO BE LABELED WITH THE OWNER'S APPROVED NUMBERING FORMAT. G. ONCE TERMINATIONS ARE COMPLETED, PERFORM CONTINUITY TESTS ON ALL VOICE AND DATA WIRING. FAULT ISOLATION WILL BE UNDERTAKEN. NECESSARY REPAIRS TO SUNSET'S WORK PRODUCT WILL BE COMPLETED AS NECESSARY. NO REPAIR OF FAILED WIRING OR CABLES BY OTHERS WILL BE UNDERTAKEN. NO "LAN CERTIFICATION TESTING" OF THE WIRING WILL BE ATTEMPTED. 2.2 CATV (TELEVISION) OUTLET SYSTEM 2.2.1 ELECTRICAL CONTRACTOR: A. ENTRANCE CONDUIT: THERE SHALL BE PROVIDED A 3" MINIMUM MAIN SERVICE CONDUIT FROM BELOW THE CATV TERMINAL BOARD TO THE PROPERTY LINE (UNLESS A LARGER SIZE IS NOTED OTHERWISE ON THE DRAWINGS OR REQUIRED BY THE CATV COMPANY). CONDUIT SIZING AND ROUTING TO BE PER THE REQUIREMENTS OF THE SERVING CATV COMPANY. B. PARAGRAPH C WILL APPLY TO ALL CATV OUTLETS SHOWN ON THE DRAWINGS C. OUTLETS: ALL CATV OUTLET BOXES SHALL BE INSTALLED WITH 4" SQUARE, MINIMUM 2 1/8" DEEP BOX AND TRIM, WITH SEPARATELY MOUNTED 20 AMP 125 VOLT DUPLEX GROUNDED RECEPTACLE ADJACENT TO CATV OUTLET. EACH CATV OUTLET BOX SHALL BE PROVIDED WITH (1)'/4" STEEL FLEXIBLE CONDUIT TO NEAREST ACCESSIBLE CORRIDOR CEILING CAVITY. PVC FLEXIBLE CONDUIT MAY BE USED IF ALLOWABLE BY LOCAL CODES. CATV COVER PLATES TO BE AS REQUIRED BY CATV SYSTEM SUPPLIER, PROVIDED AND INSTALLED BY OWNER'S TELECOM VENDOR. ALL CATV OUTLET BOXES TO BE LOCATED AS SPECIFIED ON PLAN. CATV OUTLET BOXES NOT USED SHALL BE PROVIDED WITH BLANK COVER PLATES TO MATCH SWITCH AND RECEPTACLE PLATES. D. PROVIDE AND INSTALL CATV CABLING AS REQUIRED FROM EACH OUTLET SHOWN TO CATV TERMINAL BOARD. PROVIDE CABLING PER SYSTEM VENDOR REQUIREMENTS. ALL CABLES SHALL BE IDENTIFIED ON BOTH ENDS WITH PERMANENT, DURABLE, LEGIBLE, LABELS. LABEL ACCORDING TO OWNER'S NUMBERING SYSTEM. CABLES SHALL BE CONTINUOUS WITHOUT SPLICES OR DAMAGE FROM OUTLET TO APPROPRIATE TERMINAL BOARD IN ELECTRICAL ROOM 145. LABEL CABLES AT CEILING OF ELECTRICAL ROOM 145 WHERE CABLES ENTER ROOM AND AGAIN 10' FURTHER DOWN THE RUN. AT CATV TERMINAL BOARD, LEAVE 25' OF EXTRA CABLE COILED AND PROTECTED FROM DAMAGE AT CATV TERMINAL BOARD. LEAVE 12" OF SLACK AT ROOM END. VERIFY ALL REQUIREMENTS WITH OWNER AND SYSTEM VENDOR PRIOR TO BID. 2.2.2 ELECTRICAL CONTRACTOR: A. PROVIDE AND INSTALL EACH CATV COVER PLATE AND F81, 3GHZ STYLE JACK WITH BLUE BARREL. B. TERMINATE THE ROOM END OF EACH CATV COAX. 2.3 OFFICE TELEPHONE AND INTERNET WIRING REQUIREMENTS A. A MINIMUM OF 6 TELEPHONE AND 6 INTERNET CABLE RUNS WILL BE PROVIDED TO THE AREA SPECIFIED UNDER THE FRONT DESK. THE BOXES FOR THESE CABLES WILL BE DUAL GANG BOXED MINIMUM OF 2 1/8° DEEP. B. THE 6 TELEPHONE LINES WILL BE INSTALLED IN ONE OF THE DUAL GANG BOXES AND THE 6 INTERNET LINES WILL BE IN THE OTHER DUAL GANG BOX. ELECTRICAL CONTRACTOR TO LEAVE AT LEAST 18" OF SLACK AT THESE BOXES AND LABEL EACH RUN. C. TO THE LEFT OF THE FRONT DESK WINDOW ON THE ANGLE WALL THERE WILL BE 2 TELEPHONE AND 2 INTERNET CABLE DROPS. THESE ALSO WILL BE IN A DUAL GANG BOX MINIMUM OF 2 1/8" DEEP. D. ALL TERMINATIONS AT FRONT DESK FOR TELEPHONE AND INTERNET JACKS WILL BE DONE BY OWNER'S TELECOM VENDOR. PART 3 - EXECUTION 3.1 PROVIDE AND INSTALL PULL BOXES AT ALL LOCATIONS AS REQUIRED BY NEC AND THE COMMUNICATION SYSTEMS SYSTEM SUPPLIER. 3.2 PROVIDE AND INSTALL CONDUIT SLEEVES THRU FLOORS AND WALLS AS REQUIRED FOR CABLE INSTALLATION. 3.3 ALL CONDUIT ENDS SHALL BE EQUIPPED WITH NON-METALLIC INSULATED BUSHINGS. 3.4 TERMINATE CONDUIT RUNS TO/FROM THE ASSOCIATED TELEPHONE, DATA, OR CATV BACKBOARD IN A CLOSET OR DESIGNATED SPACE AT THE TOP OR BOTTOM OF THE BACKBOARD. CONDUITS SHALL ENTER CLOSETS NEXT TO THE WALL AND BE TERMINATED AND BUSHED 6" ABOVE OR BELOW THE APPROPRIATE BACKBOARD. 3.5 WHERE DRILLING IS NECESSARY FOR VERTICAL CONDUITS, LOCATE HOLES SO AS NOT TO AFFECT STRUCTURAL SECTIONS SUCH AS RIBS OR BEAMS. 3.6 ALL EMPTY CONDUITS LOCATED IN EQUIPMENT CLOSETS OR ON BACKBOARDS SHALL BE SEALED WITH A STANDARD NON -HARDENING DUCT SEAL COMPOUND TO PREVENT THE ENTRANCE OF MOISTURE AND GASES AND TO MEET FIRE RESISTANCE REQUIREMENTS. 3.7 CONDUIT RUNS SHALL CONTAIN NO MORE THAN FOUR QUARTER TURNS (45 DEGREE BENDS) BETWEEN PULL BOXES/BACKBOARDS. 3.8 ALL TELEPHONE, DATA, AND CATV CABLE INSTALLATION SHALL BE PROVIDED WITH "J" HOOKS LOCATED A MAXIMUM OF 5'0" ON CENTER FROM DEVICE LOCATION TO THE RESPECTIVE TERMINAL BOARD. 3.9 CONTRACTOR TO PROVIDE (1) ONE 3" EMPTY CONDUIT WITH PULL STRING FORM EACH CORRIDOR TO THE SECOND FLOOR STORAGE ROOM FOR FUTURE USE. END OF SECTION r Aj1 22 20V,;1. REVIEWED FOR MPLIANCE WITH FPA 70 -NEC t1 JUN 3 0 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas qty 6700 Antioch Plaza Bentonville Suite 300 Phoenix ' Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa. Kansas 66215 P 913 322 5150 • F 913 322 5155 www.AcedusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 1•01° WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title ELECTRICAL GENERAL NOTES Sheet No. E-10 BRR Original printed on recycled paper