Loading...
HomeMy WebLinkAboutPermit EL17-0463 - WASHINGTON PLACE - SOLAR PANELS AT LANDMARK HOTEL ENTRANCEWASHINGTON PLACE SOLAR 223 ANDOVER PARK E ELI 7-0463 Parcel No: Address: c City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 0223100090 Permit Number: EL17-0463 223 ANDOVER PARK E Project Name: WASHINGTON PLACE - SOLAR Issue Date: 11/13/2017 Permit Expires On: 5/12/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WASHINGTON TOWERS LP 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 MARISA MORA-ZAPATA Phone: (800) 865-9005 2910 FIRST AVE S - SUITE 201, SEATTLE, WA, 98134 SOLTERRA GLOBAL LLC Phone: (206) 462-1103 2910 FIRST AVE S - SUITE 201, SEATTLE, WA, 98134 SOLTEGL838BS Expiration Date: 1/10/2019 /II DESCRIPTION OF WORK: INSTALLATION OF (60) LUMOS 300W SOLAR PANELS TO SERVE AS AN AWNING/PORTE COCHERE AT THE ENTRANCE TO THE LANDMARK HOTEL. (1) FRONIUS 17.4KW INVERTER Valuation of single family: $0.00 Valuation of mf/comm: $238,000.00 Type of Work: TENANT IMP Fees Collected: $4,514.65 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 it rirtAl Permit Center Authorized Signature: 0 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit air t agree to the conditions attached to this permit. Signature: Print Name: P, ( &s(d4.r Date: 1143' 43' /7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKri, . Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: (19' 1 1,9- 1 7 Date Application Expires: i _ (' -17 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0223100090 Site Address: 223 Andover Park East Suite Number: Floor: Tenant Name: Washington Place Hotel and Apartments (Landmark Hotel) New Tenant: ❑ Yes ❑ ..No PROPERTY OWNER Name: Marisa Mora -Zapata (Solterra) Address: 2910 1st Ave S #201 Name: Omar Lee Phone: (800) 865-9005 Fax: (800) 865-0045 Email: solaradmin@solterra.com Address: . City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Marisa Mora -Zapata (Solterra) Address: 2910 1st Ave S #201 City: Seattle State: WA Zip: 98134 Phone: (800) 865-9005 Fax: (800) 865-0045 Email: solaradmin@solterra.com ELECTRICAL CONTRACTOR INFORMATION Company Name: Solterra Global LLC Address: 2910 1st Ave S #201 City: Seattle State: WA Zip: 98188 Phone: (800) 865-9005 Fax: (800) 865-0045 Contr Reg No.: SOLTEGL838BS Exp Date: 1/2019 Tukwila Business License No.; (in progress) Valuation of Project (contractor's bid price): $ 238,000 Scope of Work (please provide detailed information): Installation of (60) Lumos 300w solar panels to serve as an awning/ porte cochere at the entrance to the Landmark Hotel. (1) Fronius 17.4kW inverter, Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Awning/porte cochere Type of work: ❑ New El Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator 0 Fire Alarm ❑ Telecommunication 0 Temporary Service Property Served by: D Puget Sound Energy 0 Seattle City Light H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 O Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Marisa Mora -Zapata (Solterra) Day Telephone: Date: 6/13/2017 (503) 680-9837 Mailing Address: 2910 1st Ave S #201 Seattle WA 98134 City H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $3,646.45 EL17-0463 Address: 223 ANDOVER PARK E Apn: 0223100090 $3,646.45 ELECTRICAL $3,472.81 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $3,472.81 TECHNOLOGY FEE $173.64 TECHNOLOGY FEE R000.322.900.04.00 0.00 $173.64 TOTAL FEES PAID BY RECEIPT: R12775 $3,646.45 Date Paid: Monday, November 13, 2017 Paid By: SOLTERRA Pay Method: CHECK 1465 Printed: Monday, November 13, 2017 11:47 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY I PAID PermitTRAK $868.20 EL17-0463 Address: 223 ANDOVER PARK E Apn: 0223100090 $868.20 ELECTRICAL $868.20 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11750 R000.345.832.00.00 0.00 $868.20 $868.20 Date Paid: Monday, June 19, 2017 Paid By: SOLTERRA Pay Method: CHECK 1147 Printed: Monday, June 19, 2017 1:58 PM 1 of 1 CMSYSTEMS INSPECTION RECORD Retain a copy with permit INSP CTION N0. PRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: p Type of Inspection: %/�, s n Date Called: Spec Special ructions: • Date Wanted: 6g.: Requester: Phone No: paApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: k\tfc,rip 11-9e- 0 Inspector: Date: REINSPECTION' FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPE TION NO. INSPECTION RECORD Retain a copy with permit "—'2- P MIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367 Project:j/k Loci& I/ea T I tea: 6—Nrkt„.., Address: -3 Date Called: Special Instructions: Date Wanted: 5 "(1 a. .. Requester: Phone No: EMENTS: pproved per applicable codes. I)(,I Corrections required prior to approval. aeVta,e ift* Z (60(..,, , Th P&mor Qth Pte( 6.01 v -v-1-63 Inspector: J/ jO\ Date: 95140 REINSPECTIONFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 -14-- fAl Project: kik-.t ) Type of Inspectior�.T'/a�/� /1/y{ Address: // '�j , {�� Date Called: 11 , - Special Instructions: Date Wanted: a.m 12 p.m. Requester: Phone No: q z.s 773 (13? Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: PA' (10 gl(f161-i00. tlit -ktIfi fr) .. .-- e0k/K 51-0V �1 D 4 Inspector: ti\ifiei, Date: 11 f't_C. 97 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit tLt7o5PIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: �y. G qq "T• Likr, �$4�f-A-p Type of Inspection: 71 % i,00-64t'k" Date Called: I #1, Address: 5 .\ �• % Special Instructions: Date Wanted: C f� Wim._ Requester: t, r 14 -ii t tf / 14)) -7— P- (0--0745 LI Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: %— Inspector: '-' .-/ tAltilt Lo ci&Niti r 64 Puy - 36--cm,6 r2, -,3X/ F C' �d � Y ,� ik. (ili �/�\ rd -.3 � ,L 0-- t, r 14 -ii t tf / 14)) -7— P- (0--0745 LI Date: 1-71,7 REINSPECTION EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE MIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ! 'A _ ?k.c.e Typeofinspection: rfIW/ /�((OJtt ..3Address: 'aJ Date Called: Special Instructions: -14%-\ / s 14" Date Wanted: I I i�� �m. pF% Requester:5) r iO `t7" Phone No: ?70 ''o7 92,1 Approved per applicable codes. COMMENTS: siCorrections required prior to approval. )5 A -4D P!L RAJ(% Inspector: ei\idek Date: l b ' REINSPECTION EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REVISIONS No changes shall beae to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. El -n- O1('3 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and adcnowledged By: /' Date: 1/41317 City of Tukwila BUILDING DIVISION ELIC- 0L14,3 SEPARATE PERMIT REQUIRED FOR: I ochanical 0 Electrical lialtlumbirg arias Piping City of Tukwila BUILDING DIVISION,, REVIEWED FOR �J COMPLIANCE WITH NFPA 70 - NEC NOV 0 7 2017 S �3 w City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 16 2017 PERMIT CENTER r#735 - Landmark Hotel - Omar Lee Job Name Home Phone: Cell: 206-351-6277 Client Name: Omar and Christine Lee Job Address: 223 Andover Park Way, Tukwila WA 98188 Email: omarplee@gmail.com Utility Account #: New Construction Utility Jurisdiction: PSE 7 Construction Roof Pitch: 1:12 Stories: 1.5 Steel Structure Standing Seam o Metal- Dektites ❑ Membrane/ ❑ Torchdown Y N Vaulted Ceilings Electrical Line Side Tap Y N El El Last Updated: 04/13/2017 System TSRF: 40% -Blank GSX Glass Roof Layout - 300W GSX Module REVIEWED t F rSX �sodules (60 Solar, 30 Blank) COMPLIANCE NFPA 70 - NEC NOV 0 7 2017 • City of Tukwila ,BUILDING DIVISIOI Meter new Height: 3'x3' Level Area by Meter: Yes: ❑ No: ❑ Interior Exterior Inverter Location: Conduit run Y N Monitoring > 50' �a Panel Brand Amps Building Permit: Fire Paths Required: Yes: ❑ No: 0 Yes: ❑ No: ❑ Add'I electrical work? k Type: Yes ❑ No ❑ System kW/ # of Modules 18 kW / 60 Module Make & Lumos GSX 300 Wattage Inverter(s): Make ` Quantity Wattage Fronius 1 17.4kW Module Frame Color: Black: ■ Silver: ❑ Module Back Sheet: Clear: ■ White: 0 PSCCU LOAN: Yes ❑ No See electrical site plan for inverter location 4 I -A ii x Fi xi r 2% slope (-1.1°) 1 1 Solar installation will include external conduit runs, safety disconnect, and production meter base. Solterra will minimize the visual impact of such conduit runs with aesthetics of installation in mind. Solterra electrical team will ultimately determine conduit path based on local and NEC compliance and requirements. 91-4 RECEIVED CITY OF TUKWILA I approve this design and acknowledge that Solterra Systems reserves the right to make in _field design clams should the need arise. JUN16 L1 �' Designed By: Aimee X PERMIT Cc E_ So:LTERRA LmDs pir a..•�- - GSXI E3IFI Module System Bifacial solar mc.:dule. itintegrated weatherproof mounting system Features Frameless Module Constrained Module Mounting Glass -Glass Construction Benefits • PID Free- • Lower profile • No module grounding • Perfect alignment • Concealed junction box and conductors • Tamper resistent mounting • Highest durability • Bifacial Cells Integrated Weatherproofing Technology • Seamless PIP"^r- Proudly Made in the USA / Perfect. Welding / Solar Energy / Perfect Charging PROLIEEV2 217R10 LIVL® / Powering commercial projects that last. The Fronius Symo. SHIFTING THE LIMITS o�U11 .,, -�;\ , J� 'C Ho.trd t iy / SnaplNvetter `1` / It c. rated Data `` / rlexible 1�� \:.2, t. / s. ii i Grid.,,,,, / AFC] & NLC lacnuac ul - i Mounting Syatc m .. (omrnrrt5icanon �( lkst n 1t 1,1 Read y __.,,„_____.i.2014 Comphaiti .- iL__._ FROMMMVO / Featuring ten models ranging from 10 kW to 24 kW, the transformerless Fronius Symo is the ideal compact three- phase inverter for all commercial applications. The high system voltage and wide input range ensure maximum flexi- bility in system design. With low roof loading, NEMA 4X and 1000 V DC rating, the Fronius Symo can be mounted in many differentways, including flat on a roof or on a pole. The modern design is equipped with the SnaplNverter mounting system, allowing for lightweight, secure and convenient installation. Several industry-leading features are available with the Fronius Syrno including Wi-Fig'* and SunSpec Modbus interfaces for seamless monitoring and data - logging, field proven Arc Fault Circuit Interruption (AFCI), NEC 2014 compliant, and Fronius' superb online and mo- bile monitoring platform Fronius Solar.web. TECHNICAL DATA FRONIUS SYMO (10.0-3 208-240, 12.0-3 208-240, 10.0-3 480, 12.5-3 480, 15.0-3 208) [INPUT DATA jSYMO 10.0-3 208-240 SYMO 12.0-3 208-240 E SYMO 10.0-3 480SYMO 12.5-3 480 ' SYMO 15.0-3 208 9.5 15.5 8.0. 13.0 8.0 13.0 Recommended 1'V power (kWp) LMaxx. usable input current (MPPTI/MPPT 21 ,s 25.0 A/16.5 A 10.0 . 16.0 12.0 19.5 Max. usable input current total (N1PP1- 1 + M1'PI' 2) ,_.t�(Itu�'�R t IR t� WITH q/y,y r,:���(L�� I 50.0 A M.arr short circuit currcat(I.5 DIM_ (max)MPI'I'i ii 75.0A Integrated DC string fuse holders is • i 6- and 6+ rMPI' vOlia e range ,t 300 500 V '. _ 00 V 350 00 V 325 850 V Operating voltage range 200- 600 V 200 1000 V 325 - 1000 V hlax. iiorut voltage i1 600 V ,(O](�-� tp' V I Y Wi LU 11 10(1 V_ N N 685 V 325 V NA_____I NA Nominal input. voltage 2(18 V 350 V 35 r 240,, 370 V 371 V NA 480 V NA N 675 V c size 1 Mltnissa}!le conductor size DC AWG 14 - AW( 6 co mr ducY r AW f14 -. 1'ko-,. r Siii1 _'_' '_ r ^_-. 'J� Yd9 i l !■Rha umtnr City of Tu ivu�la BUILDING DIVISION with input combiner iNumbe.r of MIT l' 1 OUTPUT DATA Max. output power SYMO 10.0-3 208-240' SYMO 12.0-3 208-2401; SYMO 10.0-3 480 if SYMO 12.5-3 480 1` SYMO 15.0-3 208 f 208 V 9995 VA Max. continuous output current Recommended OCI'D/AC breaker size 11995 VA NA • NA 15000 VA 240 V, 9995 VA ct 1.1995 VA I NA NA 1 NA 480 V NA NA 9995 VA 12495 VA NA 208 7[ 24(1 V 480 V,,: 208 V 27.7 A 33.3 A ii NA NA 41.6 A 24.0 A 28.9 A NA NA NA NA 35 A 240511 480 V 30 A NA NA 45 A � - 1.2.0 A �� 15.0 A r1 NA I NA if "AR.Ec.1VFO' 15 A 98.1 % -11 98.1 % 11 97.3% 40A NA Max. Lfti tuncy CGC Efficiency 97.0 % 97.0 % 208 V 96.5 ".o 96.5 % NA NA 240 V 96.5 % 480 V NA 96.5 NA NA NA J V Vi„ 96.5 'i 97.0 % Nn LAdtmssa ttic conductor siac AC Grid connection 1irruenry Total harmonic distortion 208 / 240 V 208/240 V AWG Iq ,AWG G Ern �`INfiI 480 V Delta +N 60 Hz < 1.5 <1.75% <1.75" < 1.5 % < 3.5% _Power factor iL__ n . 1 Ind./eap. - 1 TECHNICAL DATA (10.0-3 208/240, 12.0-3 208/240, 10.0-3 480, 12.5-3 480, 15.0-3 208) [-GENERAL DATA Dimensions (width x height x depth) Ucgree of,pmledivn Night lime consumption STANDARD WITH ALL FRONIUS SYMO MODELS 20.1 x 28.5 x 8.9 inches NEMA 4X 1 W I wertergeology Cooling hmtallation Ambient operating temperature. range Permitted humidity DC connection terminals T'ransforrrerless Variable sped fan -J Indoor and outdoor installation -40°F - + 140'1- (40 +60 `C) AC mnieUimr le mivais Ccrtiticales and compliance with standards (Except Syron 1.5.0 208 V) Cei0ficttcs and compliance with standards UL 1741-2015, ULI998 (for fund iona: A EC1, RCM')and isolation monitoring), litiL• 1547-2003, ILLI 1547.1.2003, ANS.IJLLEE C62.41, 0911c, 75.0 208 11- PCC Parr 15 A 8 A, NEC; 2014 At ticlef 90 C22. 2 No. 107-.1'01 (S plemlxr 2001) , UL16998 Issue 2 2013, CSA'11L M,07 lasuc 1 201.3 U • IQO % (nonrondenaing) 6x DC+:rod 6x DC- screw terminals for copper (solid / stranded/ line stranded) or ali nimuut (scilid / stranded) Screw lc:minats 146 AWG UL 1741 2010, 11LI998 (for functions: AFCI and isolat inn monitoring), IEEE 1547 2003, IEEE 1547.1-2008. ANSI/IEEE 062.41, FCC fart 15 A & 0, NEC Article 690, C22. 2 No, 107.1 01 ( September 2001). UL16996 Issue 2 2013, CSA TIL M 07 Issue 1 2(113 GENERAL DATA Weight PROTECTIVE DEVICES AFCI & 2014 NEC Compliant SYMO 10.0-3 208-240SYM012.0-3 208.240] SYMO 10.0.3 480 SYMO 12.5-3 480 SYMO 15.0-3 208 1 91.9 lbs. 76.7 lbs. 75,3 lbs. LDS disconnect DC reverse polarity protection [Ground Fault Protection with isolation Monitor Interruplcr IL STANDARD WITH ALL FRONIUS SYMO MODELS Yrs Yes Yes Yes INTERFACES AVAILABLE WITH ALL FRONIUS SYMO MODELS 11813 (A socket) Datalogging and inverter update possibly-. via 11511 12x 86422 (8(45 socket) f Fr'onius Solar Not, interfaceprotocol AVAILABLE WITH THE FRONIUS DATAMANAGER 2.0 CARD ( ONLY ONE CARD REQUIRED FOR UP TO 100 INVERTERS ) j Wi Fi/lithornet/Serial/ Dal;dogger and webscrver !� Wireless standard 802.11 b! 6 inputs and 4 digital I/Os *`+N for sensing purposes - no current carrying conductor. �In / Froniva Solacwcb, Stm5pec: Modbus T a Q Load management: signaling, multi) repos I V1 EB FOR TECHNICAL DATA (15.0-3 480, 17.5-3 480, 20.0-3 480, 22.7-3 480, 24.0-3 480) INPUT DATA SYMO 15.0-3 480 j SYMO 17.5-3 480 MPLIANCE WITH NFPA 70 - NEC NOV 07 2017 City of -Tukwila BUILDING DIVISION SYMO 20.0-3.480 ;1 SYMO 22.7-3 480 !SYMO 24.0-3 4801 Recommended I'V power (kWp) 1.2.0 19.5 14.0 23.0 16.0 26.0 18.0 29.5 19.0 31.0 rMax. usable input current MPPT1/MPPT 2) S,! 33.0A/25.0A Max. usable input current Mal (MITT 1 + nwirr 2) 51 A Max. array short circuit current (1.5 ° Intax) MPPT ',r 49.5 A / 37.5 A ,1,/ MPF' F 2) 1 Integrated DC siring fuse holders NA NA rr 350 - 800 V 400 800 V 450 800 V 500 - 800 V 500 800 V 200 1000 V MPP -voltage range Operating voltage range Max, input voltage Nominal input voltage 6 and 6+ 1000V 208 V NA NA NA 240'/ 480 V NA 685 V NA 695V 710V 11 NA RECEIVED -I C1TY OF TUKWILA 720 V 720 V Admissablcconductor aisc DC Number of 8IPI'I" AWG 14 AWG 6 cnppei direct. AWG 6 aluminum direct, AWG 4 2 AWG 2 copper or alittnintunIONtlinloii PERMIT CENTER TECHNICAL DATA (15.0-3 480, 17.5-3 480, 20.0-3 480, 22.7-3 480, 24.0-3 480) OUTPUT DATA SYMO 15.0-3 480 1 SYMO 17.5-3 480 Max. output power 208 V NA NA 240 V NA 480 V 14995 VA NA Max. rnnti!mous output current 208 Vel 240 V NA 17495 VA NA SYMO 20.0-3 480! SYMO 22.7-3 480 !I SYMO 24,0-3 480 NA NA NA NA � NA j NA 19995 VA 22727 VA NA NA' I Oso V 18.0 A •( Recommended OCI'D/AC breaker size 208 V NA 240 yr 480 V t Max. Efficiency CL'C Efficiency NA NA NA NA 23995 VA NA 1 NA 21.0 A NA 24.0 A 27.3 A Jt 28.9 A NA NA NA NA 25 A It NA 3)) A NA 1 NA [ NA 30A 35A 40A 208 V 98.0"6 NA NA NA 98.0 1, � 1 NA NA 240 V) 480 V NA 97.0 NA 97.5'9 IL NA 97.5 'i, Atimissable conductor sia. AC Grid connection iFrequent,' final harmonic distortion Power factor �( *Y+N for sensing purposes • no currentcarrying conductor. < I.5% <1.25% AWG 14 AW(L6 480 V Delta +N*' 60Ilr. < 1.0 0 t ind./cap. TECHNICAL DATA (15.0-3 480, 17.5-3 480, 20.0-3 480, 22.7-3 480, 24.0-3 480) GENERAL DATA NA NA QED 97 . NOV 0 7 2017 ". City of .Tukwila- BUILDING DIVISLON STANDARD WITH ALL FRONIUS SYMO MODELS 1 I Dimensions (width x height x depth) EDtlrce of ,rt ot(.ction 20.1 x 28.5 x 8.9 inches NEMA 4X Night time consumption Covert'• topology Cooling I .I nsta1Ii)t ion Ambient operating temperature range 1 W Tramsfornerlcss Variable speed fan Indotol and outdoor installation -40'1' - + 140 1. (-40 - +60'C) Pcnnitted hwnidity DC connection terminals AC connection terminals Certificates and compliance with standards 0 100 % (non condensing) a Oa DC+ and (,x DC screw terminals fur copper (solid / stranded / line stranded) or aluminum (solid / stranded) Screw terminals 14G AWG 00 1741-2010. 1)LI998 (for functions: AFCI and isolation monitoring), I000 1547-2003, IEEE 1547.1-2008. ANSI/IEEE C62.41.1 -CC Part .15 A & Il, NEC Article 690, C22. 2 No. 107.1 01 ( September 2001). U1,169911 Issue 2 2013, CSA T)L M )17 Issue 1 2013 GENERAL DATA SYMO 15.0-3 480 SYMO 17.5-3 480 SYMO 20.0-3 480 Weight 95.7 lbs. SYMO 22.7-3 480 i' SYMO 24.0-3 480-1 PROTECTIVE DEVICES STANDARD WITH ALL FRONIUS SYMO MODELS AI'C1 & 2014 NEC Compliant Yes DC disconnect Ye* DC reverse polarity protection Yes pGround Fault Protection with Isolation Monitor LInlerngper L. Yes INTERFACES IISO (A socket) RECEIV-ED, AVAILABLE WITH ALL FRONIUS SYMO MODELS CITY OF TU KWILA Dat: logging and inverter update possible via )1511 2x 115422 (8145 socket).( Fronius Solar Net, interface protocol N 1-6 2011 AVAILABLE WITH THE FRONIUS DATAMANAGER 2.0 CARD ( ONLY ONE CARD REQUIRED FOR UP TO 100 INVERTE Wi Pi/Ethernet/Serial/ Dalalo *er and webserver Wireless standard 802.11 bfg/n / Fmniva Solar.web, SunSpec Modbus TCP, (SON / SunSpcc Modbus R10 6 inputs and 4 digital 1/Os Load management: signaling, nmltipiupose I/O PERMIT CENTER e FRONIUS SYMO 24.0-3 480 TEMPERATURE DERATING CURVE 25,000 20,000 0 it 15,000 0 10,000 5,000 0 80 90 100 110 120 AMBIENT TEMPERATURE E°F] • 500 v,,, a 720 Vpc • 800 VDC FRONIUS SYMO 24.0-3 480 CEC EFFICIENCY CURVE 85 80 75 70 0 0.1 0.2 0.3 0.5 0.75 1 STANDARDISED OUTPUT POWER P /P - AC AC,R • 500 VDc a 725 Vnc • 800 VDC / Perfect Welding / Solar Energy / Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY. / Whether welding technology, photovoltaics or battery charging technology - our goal is clearly defined: to be the innovation leader. With around 3,300 employees worldwide, we shift the limits of what's possible - our record of over 900 grained pat eitt s is testimony to this. While others progress step by step, we innovate in leaps and bounds. Just as we've always done. The responsible use of our resources forms the basis of our corporate policy. REVIEWED FOR COMPLIANCE WITH , NFPA 70 NEC NOV 07 2011 City orTukwUa BUILDING DIVI$ION RECEIVED CITY OF TUKWILA Further information about all Il1.0111.115 products and OW global sales partners and representative. can be found at www.fronius.com R b JUN 1 6 2011 rO5May2015EN PERMIT CENTER e)® US SUI1SPEC ••••••{ILLILINCE--• Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA pv-support-usa@fronius.com www.fronius-usa.com PV ARRAY INFORMATION # OF MODULES IN BRANCH: 12 # OF PARALLEL BRANCHES: 4 LOWEST AVERAGE TEMP: -5 C HIGHEST AVERAGE TEMP: 45 C PV MODULE RATINGS @ STC MODULE MANUFACTURER: Lumos MODULE MODEL: GXT 300 OPEN CIRCUIT VOLTAGE: 40.45 Vdc SHORT CIRCUIT CURRENT: 9.91 A MAX SERIES FUSE (OCPD): 15 A MAXIMUM POWER VOLTAGE: 32.48 Vdc MAXIMUM POWER CURRENT: 9.24 A MAXIMUM POWER: 300 Wp4 INVERTER RATINGS INVERTER MAKE:Fronius Symo 17.5-3 (480V) INVERTER MODEL: Symo 17.5-03 MAX PV VOLTAGE (OC) = 1000 v MAX PV CURRENT (IC) = 75 A (per tracker) MAX POWER @40C=17500W NOMINAL AC VOLTAGE = 480 V MAX AC CURRENT = 21 A PHOTOVOLTAIC ARRAY CHARACTERISTICS SIGN: 690.53 PHOTOVOLTAIC POWER (SOURCE SIGN ON DC DISCONNECT) RATED POWER = 18 kW RATED CURRENT =27.6 A RATED VOLTAGE = 404.5 V MAX SYSTEM VOLTAGE = 453.04V MAX SYSTEM CURRENT = 34.5 A (5) 810 AWG thhn in (1(% EMT All solar equipmenleb be located outside. Tile plan for final loca03 O 6 -STRINGS (10) SW 345 MODULES IN SERIES (+) Fronius Rapid Shutdown device located on array (5) #8 AWG THHN wire (1) 1 Inch EMT ort %PVC where located below grade< 150 ft to main service panel to array (V_d = 0.29%) Integrated DC Disconnect (+) DC (-) AC 0 60 AMP 3 Phase 480 volt AC Disconnect Bond to Steel structure with #6 CU REVIEWED .FOR. ,.. COMPLIANCE WITH NEPA 70 - NEC NOV 0 7 2017 City of Tukwila BUILDING DIVISION Inverter located on back of building see site plan for location 100 AMP 3 phase 480 volt meter Distance from production meter is greater than 6 ft from the net meter. Location noted on site plan PHOTOVOLTAIC POINT OF 690NTEIUC,(4LEIU PUW SIGN: (SOURCE SIGN ON AC DISCONNECT) RATED POWER STC =18 kW SYSTEM AC VOLTAGE = 480 Vac SYSTEM AC CURRENT = 26.25 A (5)#10THHNin% inch EMT 200 amp 480 volt panel HK1 located in electrical room shown on site plan 30A-3Pole Breaker to match panel type \TLOAD To Utility DRAWN BY: AM DATE 4/7/17 Landmark Hotel PV ELECTRIC PLAN 3220 1st Ave. So. 8800 Seattle, WA 98134 SIZE B FCSM NO. DWG. NO. REV 0 S::: LTERRA SYSTEMS SUN 4 EARTH ENERGY SOLUTIONS o. 800.865.9005 f. 800.865.0045 SCALE NTS SHEET 4/2/2018 City of Tukwila Department of Community Development MARISA MORA-ZAPATA 2910 FIRST AVE S - SUITE 201 SEATTLE, WA 98134 RE: Permit No. EL 17-0463 WASHINGTON PLACE - SOLAR 223 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/21/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/21/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 111 Rachelle pley Permit Technician File No: EL17-0463 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 11/2/2017 City of Tukwila Department of Community Development MARISA MORA-ZAPATA 2910 FIRST AVE S - SUITE 201 SEATTLE, WA 98134 RE: Permit Application No. EL17-0463 WASHINGTON PLACE - SOLAR 223 ANDOVER PARK E Dear MARISA MORA-ZAPATA, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/16/2017, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of UNDER REVIEW and is due to expire on 12/16/2017. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL17-0463 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 August 01, 2017 City of Tukwila Department of Community Development MARISA MORA-ZAPATA 2910 FIRST AVE S - SUITE 201 SEATTLE, WA 98134 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL17-0463 WASHINGTON PLACE - SOLAR - 223 ANDOVER PARK E Dear MARISA MORA-ZAPATA, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PLANNING DEPARTMENT: Minnie Dhaliwal at 206-431-3685 if you have questions regarding these comments. • 1. If the proposed changes are visible from the exterior then submit building elevation showing the proposed changes. Additionally, a modification to the approved design review approval is required for any modifications to the exterior from the design review approved by the Board of Architectural Review. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, •RDLP y�C Bill Rambo Permit Technician File No. EL17-0463 6300 Southcenter Boulevard Suite #100 • Tukwila Wn.chinptnn 921RR • Phony 2n6 -431-367n • Fnr 7n6-4? 1-gKKs QERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0463 DATE: 10/26/17 PROJECT NAME: WASHINGTON PLACE - SOLAR SITE ADDRESS: 223 ANDOVER PARK E Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ Fire Prevention Structural Planning Division 1111 Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/31/17 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 11/28/17 Approved Corrections Required n Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 ;EMIT COORD COPY C PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0463 DATE: 06/16/17 PROJECT NAME: WASHINGTON PLACE - SOLAR SITE ADDRESS: 223 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: J two 141 Building Division Public Works Fire Prevention Structural VitS Cover 2 Planning Division III Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/20/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/18/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only Q 1 CORRECTION LETTER MAILED: U t Departments issued corrections: I3Idg ❑ Fire ❑ Ping (— PW ❑ Staff Initials: 12/18/2013 U City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: CD I c Plan Check/Permit Number: EL 17-0463 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Washington Place - Solar Project Address: 223 Andover Park E Contact Person: A/ r1SA 416 ra - 241 hone Number: - (so 3 p LPgp —1 3 . Summary of Revision: _'Q (Q� REGE1VED CITY OF TUKWILA neRe�e 1 LOL PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi o Received at the City of Tukwila Permit Center by: ntered in TRAKiT on l 0 ')-- W ( \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: SOLTERRA GLOBAL LLC Home Espanol Contact Safety & Health 0 Washington State Department of Labor & Industries Claims & Insurance Search L&I A -Z Index Help Workplace Rights SOLTERRA GLOBAL LLC Owner or tradesperson Principals Heather, Brian, PARTNER/MEMBER Heather, Brian, AGENT Doing business as SOLTERRA GLOBAL LLC WA UBI No. 604 041 594 2910 1st Ave S #201 SEATTLE, WA 98134 206-462-1103 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SOLTEGL838BS Effective — expiration 01/10/2017— 01/10/2019 Designated administrator Marks, Andrew C License type Master Electrician Bond International Fidelity Ins Co Bond account no. SAIFSU0712189 Received by L&I 01/10/2017 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. MARKSAC882OM $4,000.00 Effective date 12/21/2016 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 173,537-02 Doing business as SOLTERRA GLOBAL LLC Page 1 of 2 SEARCH My L&I Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604041594&LIC=SOLTEGL838BS&SAW= 11/8/2017 SOLTERRA GLOBAL LLC Estimated workers reported Quarter 3 of Year 2017 "11 to 20 Workers" L&I account contact TO / KRISTINE HATHAWAY (360)902-4811 - Email: HATK235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604041594&LIC=SOLTEGL838BS&SAW= 11/8/2017