Loading...
HomeMy WebLinkAboutPermit EL17-0566 - TSD TRANSPORTATION BUILDING - SECURITY SYSTEMTSD TRANSPORTATION BUILDING 12801 E MARGINAL WAY S EXPIRED 01/24/18 ELI 7-0566 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL OTC PERMIT 2384200010 Permit Number: 12801 E MARGINAL WAY S Issue Date: Permit Expires On: Project Name: TSD TRANSPORTATION BUILDING EL17-0565 7/28/2017 1/24/2018 Owner: Name: Address: TUKWILA SCHOOL DISTR #406 4640 S 144TH ST, TUKWILA, WA, 98168 Contact Person: Name: KENNY SHOWALTER Address: 2221 CALIFORNIA ST , EVERETT, WA, 98201 Contractor: Name: SONITROL PACIFIC Address: 2221 CALIFORNIA AVE , EVERETT, WA, 98201 License No: SONITP*948D7 Lender: Name: Address: 1// Phone: (425) 252-8365 Phone: (425) 258-3655 Expiration Date: 3/27/2018 DESCRIPTION OF WORK: LOW VOLTAGE SECURITY. Valuation of single family: $0.00 Valuation of mf/comm: $13,368.00 Type of Work: NEW Fees Collected: $366.89 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature: ihyfr 2014 2014 2014 2015 Date: 1. I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: '" "/I� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portionofthe electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line:1206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB 1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. �L,�1-ate Project No. Date Application Accepted: Date Application Expires: 1•T4 L1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 12801 East Marginal Way S Tukwila, WA 98168 Tenant Name: TUSD Transportation Building PROPERTY OWNER Name: Kenny Showalter Name: Tukwila School District City: Everett State: WA Zip: 98201 Address: 4640 144th St Email: City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Kenny Showalter Address: 2221 California St City: Everett State: WA Zip: 98201 Phone: (425) 252-8365 Fax: Email: Suite Number: Floor: New Tenant: ❑ Yes ELECTRICAL CONTRACTOR INFORMATION Company Name: Sonitrol Pacific Address: 2221 California St City: Everett State: WA Zip: 98201 Phone: (425) 258-3655 Fax: (425) 258-3658 Contr Reg No.:SONITP*948D7 Exp Date: 03/27/2018 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 13,368 Scope of Work (please provide detailed information): low voltage security - adding Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes m No Type of Use: security Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel 0 Tenant Improvement 0 Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication 0 Temporary Service Property Served by: 2 Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised I-I-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 0 Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 O Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT; APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: - Date: '�� 1/':- Print Name: COMMA Y 1MA Day Telephone: (253) 878-2714 Mailing Address: 5911 Orchard ST W Tacoma, WA 98467 City State Zip W:\Permit Center\Applications-Handouts\Permit Applications 'PDF's\Electrical Permit Application Revised 1-I-17.docx Revised: January 2017 bh Page 2 of 2 Sound Security, Inc. dba Sonitrol Pacific 8220 N Interstate Avenue Portland, OR 97217 (503) 223-5822 Cust # 04STUK01 - Tukwila School District Site: TUSD Transportation Building 12801 East Martinal Way S Tukwila, WA 98168 (206) 901-8020 Job Ticket Job Number 19797-1 Sold Date 06/16/2017 Salesperson Goodwin, K Job Type Integrated Install Company SEA Project Manager Showalter, K Job Status In -Progress System Type BA Installer Permit 1 Permit 2 Permit 3 System Account: 11186 II 1111 I II 1111111111111111111111111111111111 III Notes: New Intrusion system panel #11186 and non -monitored access system panel #1000000776 Parts: Part Code Install 1007S* Description Standard Thin Proximity Card (4010) 1008 Standard Proximity Key Fob Sonitrol Logo (SNTL4085 168 AudioSensor (-PA20) 180 Pepwave Power Supply (CS27U12V-12) 190 4G Pepwave (MAX -BR 1 -LTE -US -T) Location Labor Units 0 0 0 0 0 Qty 100 20 6 1 1 Rate 0.00 0.00 0.00 0.00 0.00 Amount 0.00 0.00 0.00 0.00 0.00 246S* Outdoor 0 1 0.00 0.00 Siren(AS-SSX52) 254S* 12V 8aH Battery Back 0 1 0.00 0.00 Up 264S* 2440VA Transformer 0 1 0.00 0.00 ELK-TRG2440 4034S* Elite -36 2 -Door 0 1 0.00 0.00 Controller [2 -Door Lic] (EL36-2M) 4034S* Elite -36 2 -Door 0 1 0.00 0.00 Controller [2 -Door Lic] (EL36-2M) 434S* HID ProxPro II Standard 0 2 0.00 0.00 (Intrustial) Reader (5455B 712S* Nascom 3/4" Resessed 0 4 0.00 0.00 Contact [White] (N 1178CW/ST) 906 SONIP Keypad 0 2 0.00 0.00 913 SONIP 18" Chassis 0 1 0.00 0.00 915 FIexIP Board 0 1 0.00 0.00 0 0.00 June 20, 2017 4:12:36 PM Page 1 of 1 Sales Rep: Kerry Goodwin Customer: 1 Site Address ' Contact Info: ' TUSD-Transportation Building 4640 s 144th St Tukwila, WA Transportation Building 12801 East Marginal Way S Tukwila, WA Liliana Cardenas cardenasl@tukwila.wednet.edu 206-901-8020 TotatPurchase„P ice: $13,368.25 rorai Monthl C ih e $213.00 cu E E LLI Part #_ ` Desc tption Access control system 4034S* Elite -36 2 -Door Controller [2 -Door Lic] (EL36-2M) 4034S* Elite -36 2 -Door Controller [2 -Door Lic] (EL36-2M) 434S* HID ProxPro II Standard (Intrustial) Reader (5455B 1007S* Standard Thin Proximity Card (4010) 1008 Standard Proximity Key Fob Sonitrol Logo (SNTL4085 verified intrusion detectii 915 FIexIP Board 913 SONIP 18" Chassis 254 12V 8aH Battery Back Up 264 2440VA Transformer ELK-TRG2440 246 Outdoor Siren(AS-SSX52) 180 Pepwave Power Supply (CS27U12V-12) 190 4G Pepwave (MAX-BR1-LTE-US-T) 168 AudioSensor (-PA20) 906 SONIP Keypad 736A Single Door Sensor 1.00 1.00 2.00 100.00 20.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 6.00 2.00 4.00 evice Locatton 0 0 Access control system Install Access control system Sub -Total: verified intrusion detection system Install verified intrusion detection system Sub -Total: uarltl 19.00 19.00 23.50 23.50 Totals: 42.50 escription To Access control systen, Per Reader X 2 Equipment Maintenance verified intrusion detec Equipment Maintenance Monitoring 'otal RMR for: Access control otal RMR for: verified intrusio $40.00 $58.00 $98.00 $36.00 $79.00 $115.00 Total RMR for Project $213.00 ass. Access control system Prevailing Wage SSI - Prevailing Wage verified intrusion detection system Prevailing Wage SSI - Prevailing Wage 1.00 1.00 2 \k N § q0 k\ c± k/ /TA c o/ \k 2 E \� ko\ Vie\ CO : 0 ee= O X c0 CD 0 /�02 • t c • $\ 2 0 _ \ ƒ\\= % o E E §2 (1)o>g CI) - \U) 0\\ 'c'cascz o/o a; 0 c\k / c \ E a) -2 $t)% 7230 To co 0E $fP� \ 9 P. \ 0\\ m N.- •- \$\cu >2#£ Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $771.69 EL17-0566 Address: 12801 E MARGINAL WAY 5 Apn: 2384200010 $366.89 ELECTRICAL $349.42 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $349.42 TECHNOLOGY FEE $17.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 I $17.47 EL17-0567 Address: 13601 32ND AVE 5 Apn: 1623049038 $404.80 ELECTRICAL $385.52 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $385.52 TECHNOLOGY FEE $19.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11990 R000.322.900.04.00 0.00 $19.28 $771.69 Date Paid: Tuesday, July 25, 2017 Paid By: SONITROL PACIFIC Pay Method: CHECK 71914 Printed: Tuesday, July 25, 2017 8:21 AM 1 of 1 SYSTEMS 12/1/2017 C� Q City of Tukwila Department of Community Development KENNY SHOWALTER 2221 CALIFORNIA ST EVERETT, WA 98201 RE: Permit No. EL17-0566 TSD TRANSPORTATION BUILDING 12801 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/24/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/24/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachel e ' pley Permit Technician File No: EL17-0566 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 SONITROL PACIFIC Home Espanol Contact Search L&I Page 1 of 3 S ARCH A -Z Index Help fly L&I Safety & Health Claims & Insurance Workplace Rights 0 Washington State Department of Labor & Industries SONITROL PACIFIC Owner or tradesperson Principals Bradley, Beau, PRESIDENT Bullis, Joe (Joseph) M, VICE PRESIDENT Payne, James M, VICE PRESIDENT Bradley, Debra, SECRETARY Buckner, Lisa C, TREASURER BRADLEY, BEAU R, AGENT Doing business as SONITROL PACIFIC WA UBI No. 600 365 884 Parent company SOUND SECURITY INC 2221 CALIFORNIA AVE EVERETT, WA 98201 425-258-3655 SNOHOMISH County Business type Corporation Governing persons BEAU R BRADLEY BEAU BRADLEY; DEBRA L BRADLEY; LISA C BUCKNER; JOE (JOSEPH) M BULLIS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties LIMITED ENERGY License no. SONITP*948D7 Effective — expiration 03/27/2006— 03/27/2018 Designated administrator MOORE, GARY Active. Meets current requirements. License type License no. Electrical Administrator MOOREG*941 RN Bond ............... Contractors Bonding & Insurance Co Bond account no. PI6275 $4,000.00 Received by L&I Effective date 02/19/2013 02/20/2013 Expiration date Until Canceled Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600365884&LIC=SONITP*948D7&SAW= 7/28/2017