Loading...
HomeMy WebLinkAboutPermit EL17-0613 - JC PENNEY - UTILITY SERVICEJC PENNEY 1249 SOUTHCENTER MALL ELI 7-0613 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.gov 9202470080 1249 SOUTHCENTER MALL Project Name: JC PENNEY ELECTRICAL PERMIT Permit Number: EL17-0613 Issue Date: 10/10/2017 Permit Expires On: 4/8/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 DANIEL MOSER 1201 THIRD AVE, STE 600 , SEATTLE, WA, 98101 SEQUOYAH ELECTRIC LLC 15135 NE 92ND ST, REDMOND, WA, 98052-3519 SEQUOEL977S9 Phone: (206) 436-0436 Phone: (425) 814-6000 Expiration Date: 1/30/2019 DESCRIPTION OF WORK: NEW UTILITY SERVICE Valuation of single family: $0.00 Valuation of mf/comm: $450,000.00 Type of Work: SERV CHNG Fees Collected: $7,155.91 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: LY --� Date: (O-7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: /f C%,N Dater/%//7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Project No. Date Application Accepted:y O(Q(3 Date Application Expires: 0' {, (For once use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 9202470080 Site Address: 1249 SOUTH CENTER MALL TUKWILA WA 98188 •Suite Number: Tenant Name: JCPenney PROPERTY OWNER Name: Daniel Moser Name: JCPenney Company Inc City: Seattle State: WA Address: 6501 Legacy Drive Phone: 206-436-0436 Fax: City: Plano State: TX Zip: 75024 CONTACT PERSON — person receiving all project communication Name: Daniel Moser Address: 1201 Third Avenue, Suite 600 City: Seattle State: WA Zip: 98101 Phone: 206-436-0436 Fax: Email: dan.moser@hargis.biz State: Floor: New Tenant: ❑ Yes O..No ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 450,000.00 Scope of Work (please provide detailed information): New utility service Will service be altered? 0 Yes ❑ No Adding more than 50 amps? ❑ Yes 0 No Type of Use: Type of work: D New ❑ Addition X❑ Service Change D Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: X❑ Puget Sound Energy El Seattle City Light HAApplications\Forms-Applications On Line12014 Applications\Electica1 Permit Application Revised I-1-14.docx Revised: January 2014 nn Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) O Garages, pools, spas and outbuildings O Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea O Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) O Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT; APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE OR ELECTRICAL CONTRACTOR: Signature: COAsTormaz1 h'tea Print Nanie: Mailing Address: 1501 L.ELtel bQ H:\Applications\Forms-Appiications On Linc\2014 ApplicationslElcctrical Permit Application Revised 1-I-14.docx Revised: January 2014 blt Day Telephone: {a} city Date: 8I1OI1�] O'12)431- I1G5 its 1502A State Zip Page2of2 DESCRIPTIONS ACCOUNT 1 QUANTITY PAID $306 $306.00 $306.00 $306.00 $306.00 EL17-0613 Address: 1249 SOUTHCENTER MALL Apn: 9202470080 DEVELOPMENT PERMIT REINSPECT FEE - AFTER HRS INSP FEE TOTAL FEES PAID BY RECEIPT: R15024 R000.359.000.00.01 0.00 Date Paid: Wednesday, July 25, 2018 Paid By: SEQUOYAH ELECTRIC LLC Pay Method: CHECK 555635 Printed: Wednesday, July 25, 2018 3:54 PM 1 of 1 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $5,779.77 E117.0613 Address: 1249 SOUTHCENTER MALL Apn: 9202470080 $5,779,77 ELECTRICAL $5,504.54 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $5,504.54 TECHNOLOGY FEE $275.23 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12528 R000.322.900.04.00 0.00 $275.23 $5,779,77 Date Paid: Tuesday, October 10, 2017 Paid By: SEQUOYAH ELECTRIC LLC Pay Method: CHECK 553876 Printed: Tuesday, October 10, 2017 8:24 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila PermitTRAK EL17-0613 DESCRIPTIONS Address: 1249 SOUTHCENTER MALL ELECTRICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12089 ACCOUNT Apn:9202470080 R000.345.832.00.00 QUANTITY I PAID 0.00 $1,376.14 $1,376.14 $1,376.14 $1,376.14 Date Paid: Thursday, August 10, 2017 Paid By: CALLISONRTKL Pay Method: CHECK 227266 Printed: Thursday, August 10, 2017 11:03 AM 1 of 1 SYSTEMS INSPECTION RECORD INSP CTIQN NO. Retain a copy with permit PER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: J,� r04.4641 _\•// Type of inspectioh:Address: Date Called: Special InstctiorI, Date Wanted:cr 0 a.rKi Requester: .��.ym 7'�� Phone No: to,7(h 2-3S ( Approved per applicable codes. COMMENTS: Corrections required prior to approval. Inspector: 0A/JAI Date: n il REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION N0. P RMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ?eJhi'r6, type of Inspection: 5tee_eit et Address: Date Called: Special instructions Date Wanted:m. ? 31 p.m. Requester: Phone No: I r 16 435.5. Approved per applicable codes. E Corrections required prior to approval. COMMENTS: 0 & -- X 5 fe-696e5 76 L Z1... a LI - 514'0 of",sevept6 j kes5 id Ft4 6A -s r ' (-chi` t Vie)c- G 6 . pa R. -=Q, cit , / �l R or Duc-c k_ 7` y l S L.h'T'(dni A -'J7 14-Qrt(Itriiv /, Inspector: Date:. ©7 3 (lig iO REINSPECTION FEE REQUIRED. Prior to next inspectio fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Aft INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA-BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION NO. PERMIT NO. Project: G p Qr ✓► e.. �- Type of Inspection: Se-4-iiit titsAd ress: 211'1 sc rQ 44,4„k Date Called: Special Instructions: L.j /51�‘ (.10 0 0 0 e_oi v a I"Phone OAK t tN Gh,o i‘ r. t 1461'1 1° Date Wanted: a.m. P.m. Requester: No: ti —I 3 6 proved per applicable codes. El Corrections required prior to approval. COMMENTS: inspec Gr Date;,A, )l REIt4SPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD 1 Retain a copy with permit! INSPECTION NO. P RMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project:.-� Type ?Inspection: f ir' T `� Iiti Address: 1/1114/ Date Call d: Special Instruct ion: Date Wanted: 2._ i �a,- P.m. Requester. es e , �11P��S Phone No: � 71106 10 23s5� Approved per applicable codes. Corrections required prior to approval. OMMENTS: v\.- J61 e040,,r, mit Cei .41,5 4,A,4f AJen PLL�TC InspectorcNi..°.-- :,%„'�V�c.► REINSPECTION/FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Callao schedule reinspection. Date: Jr Date: OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Requested By: Firm/Company: 1 _ Permit Number: b'-/ 7 —c' j C-///e/—S. sP44x ,. Inspection Information Project Name: JC— Pef lb (\,e� 'r ,S±11 C Project Address/Location: 9� Si?v ii Cp,Y f L ,� 14 Ai c_ Requested Date for Inspection: 7/30f Contact Name: ( /7t 1S SLR -1),y Special Conditions for Consideration: / Ct1Ca.- Requested Time: 1 . QV /PM Phone Number:(/ r) 2Z‘— JJ ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $102.00 per hour (minimum total of $306.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: / - Date: Printed Name: 1014-M DE) City Use Only. Approved: Disapproved: Paid: RECEIVED CITY OF TUKWIL t, JUL 252018 PERMIT CENTEtr Receipt No: Date of Approval/Disapproval: Remarks: Authorized Reviewer: W:\Permit Center \ Applications -Handouts \Templates\Forms \Off Hours Inspection 1-2017.docx Revised: January 1, 2017 7/2/2018 City of Tukwila Department of Community Development DANIEL MOSER 1201 THIRD AVE, STE 600 SEATTLE, WA 98101 RE: Permit No. EL 17-0613 JC PENNEY 1249 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/20/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/20/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL17-0613 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0613 DATE: 08/10/17 PROJECT NAME: JC PENNEY SITE ADDRESS: 1249 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C �'�1 Building Division Public Works n Fire Prevention Structural Planning Division nPermit Coordinator n 1 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/15/17 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 09/12/17 Approved Corrections Required n Approved with Conditions ri Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 SEQUOYAH ELECTRIC LLC I tonic 1Ssparml Contact Safety & Health Washington State Department of )Labor & Industries Search L&I Index IIelp Page 1 of 2 My I.&! Claims & Insurance Workplace Rights Trades & Licensing SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Trocano, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC WA UBI No 602 252 591 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County Business type Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003— 01/30/2019 Designated administrator NICHOLS, DAVID E License type Master Electrician Bond HARTFORD CAS INS CO Bond account no 52BSBAB5541 Active. Meets current requirements. License no. NICHODE974O6 $4,000.00 Received by L&I Effective date 01/29/2003 01/29/2003 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591 &LIC=SEQUOEL977S9&SAW= 10/10/2017 SEQUOYAH ELECTRIC LLC __ Savings No savings accounts during the previous 6 y.„r period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 061,981-00 Doing business as SEQUOYAH ELECTRIC LLC Estimated workers reported Quarter 2 of Year 2017 "Greater than 100 Workers” LFI account contact T4 / MELVINA RAMSDELL (360)902-4814 - Email: RAMM235@ini.wa.gov Track this contractor el Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 01/13/2016 Inspection no 317937437 Location 501 North Newport Ave Newport, WA 99156 Inspection results date 03/14/2012 Inspection no 315581264 Location 3003 W Casino Rd Everett, WA 98203 Violations Violations Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the atate of Wast higton. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591 &LIC=SEQUOEL977S9&SAW= 10/10/2017 co t a) O O • > 44• u L N = p O M M d• I- N N ti N- a) 0) I- IL www.jcpenney.com rI N owns 0 ca a flY0 p E J o 41111* c) X Y taN Z I. a = 2 CC IA N tin 51 O Z insitm z V) i p - U J Z o 4 Vf :i 0 W 0 a 0 0 ti o 0 0 0 0 F - 0 U w a j ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 COPYRIGHT 02016 CALLISON ELECTRICAL LEGEND AND NOTES E001 ABBREVIATIONS 1 ELECTRICAL GENERAL NOTES 2 SYMBOL LEGEND 3 AFF ABOVE FINISH FLOO AUTHORITY AVINGR DEMOLITION NOTES GENERAL ELECTRICAL SPECIFICATIONS GENERAL JURISDICTION A AMPERE AWG AMERICAN WIRE 1. THE ENTIRE SCOPE OF THE DEMOLITION WORK MAY NOT BE SHOWN ON THE ELECTRICAL PLANS. PRIOR TO BID, THE ELECTRICAL SUB -CONTRACTOR SHALL: (TO BE USED IN CONJUCTION WITH THE JCP MASTER CONTRACT SPECIFICATIONS) 1. RACEWAY INSTALLATION:. CONCEAL RACEWAY IN FINISHED SPACES, INSTALL CONDUIT STRAIGHT GAUGE BKBD BACKBOARD BLDG BUILDING a. REVIEW THE ENTIRE SET OF TENANT IMPROVEMENT PLANS, INCLUDING THE ARCHITECTURAL AND MECHANICAL TO FULLY UNDERSTAND THE SCOPE OF WORK. REPORT BACK TO THE GENERAL CONTRACTOR WITH ANY DISCREPANCIES THAT MAY AT RIGHT ANGLES AND PARALLEL WITH BUILDING LINES AND PROPERLY SUPPORT. DO NOT ATTACH TO OR PENETRATE HVAC DUCTS. MAINTAIN HEADROOM AND EQUIPMENT AND FLUE EXISTING ELECTRICAL TO BE REMOVED / j � , C CONDUIT EXIST. CLEARANCE. FIRE/SMOKE - SEAL PENETRATIONS OF RATED CONSTRUCTION. 2. WIRE: NOT LESS THAN 98 PERCENT CONDUCTIVITY COPPER, TYPE THHN/THWN, OR XHHW EXISTING ELECTRICAL TO REMAIN CB CIRCUIT BREAKER b. VISIT THE SITE AND REVIEW THE TENANT PREMISES WITH THE GENERAL CONTRACTOR INSULATION WITH 600 VOLT INSULATION. MINIMUM SIZE FOR BRANCH CIRCUITS SHALL BE #12 SEPARATE PERMIT CKT CIRCUITAND CLG CEILING CO CONDUIT ONLY LANDLORD TO FULLY UNDERSTAND THE SCOPE OF WORK AND EXISTING CONDITIONS. REPORT BACK TO THE GENERAL CONTRACTOR WITH ANY DISCREPANCIES THAT MAY EXIST. AWG. MINIMUM SIZE FOR CONTROL WIRING SHALL BE #14 AWG. 3. COLOR CODE ENTIRE WIRING SYSTEM FROM SERVICE DISCONNECT OR TRANSFORMER NEW ELECTRICAL WORK tEQ�I�Ed FOR: CONTR CONTRACTOR CT CURRENT TRANSFORMER CU COPPER DIST DISTRIBUTION DS DISCONNECT SWITCH (E) DENOTES EXISTING DEVICE/EQUIPMENT TO REMAIN c. REVIEW THE SCOPE OF WORK OF ALL OTHER DISCIPLINES AND TRADES TO FULLY UNDERSTAND THEIR SCOPE AND THE IMPACT ON THE ELECTRICAL SYSTEMS. 2. THE ELECTRICAL SUB -CONTRACTOR SHALL INCLUDE IN THE BID PROPOSAL THE COST FOR ALL WORK REQUIRED TO ACCOMMODATE THE DEMOLITION SCOPE OF WORK, INCLUDING THE INFORMATION SHOWN ON THE TI PLANS, INFORMATION DISCOVERED DURING THE SITE REVIEW, AND AS REQUIRED TO ACCOMMODATE THE TENANT IMPROVEMENT AND TO COMPLY WITH THE CODES/AHJ REQUIREMENTS. 3. MAINTAIN SERVICE TO ALL EXISTING SYSTEMS AND EQUIPMENT/DEVICES THAT ARE NOT THROUGHOUT ALL BRANCH CIRCUITS AS FOLLOWSUNLESS REQUIRED OTHERWISE BY LOCAL FOLLOWS(UNLESS CODE AUTHORITIES USE THE FOLLOWING COLOR CODING SCHEME): FOR 120/208 VOLT SYSTEM, PHASE A - BLACK, PHASE B - RED, PHASE C - BLUE, NEUTRAL - WHITE; GROUNDING CONDUCTOR GREEN; ISOLATED GROUNDING CONDUCTOR (IG) - GREEN WITH YELLOW STRIPE. FOR 277/480 VOLT SYSTEM, PHASE A -BROWN, PHASE B -ORANGE, PHASE C -YELLOW, NEUTRAL -GREY 4. SPLICES: SPLICE ONLY IN ACCESSIBLE JUNCTION BOXES, USING "WIRENUT" CONNECTORS FOR BAWL AND SMALLER, OR MECHANICAL COMPRESSION CONNECTOR WITH INSULATION KIT FOR 6AWG AND LARGER. 8. BOXES: NEMA 1 IN INTERIOR DRY LOCATIONS MATCHLINE OR PROPERTY LINE - ENLARGED PLAN BOUNDARYiffi REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE ,,,��' MChattiC�t1 IGCtdCBi ` mbing a8 Piping City of Tukwila BUILDING DIVISION EC ELECTRICAL SUB -CONTRACTOR EF EXHAUST FAN EL EMERGENCY LIGHT ELEC ELECTRICAL EM EMERGENCY SCHEDULED TO BE DEMOLISHED, THAT ARE NECESSARY FOR NORMAL OPERATIONS, THAT DO NOT CONFLICT WITH THE NEW CONSTRUCTION OR THE INTENDED USE OF THE SPACE, AND THAT ARE REQUIRED BY THE LANDLORD OR OTHER TENANTS TO REMAIN IN PLACE. RELOCATE EQUIPMENT TO MAINTAIN SERVICES IF NECESSARY TO ACCOMMODATE RENOVATION. 4. UNLESS NOTED OR DIRECTED OTHERWISE, THE ELECTRICAL SUB -CONTRACTOR SHALL CAST WEATHERPROOF TYPE IN WET LOCATIONS. 9. GROUNDING: PROVIDE CONTINUOUS, PERMANENT, AND EFFECTIVE GROUNDING SYSTEM. GROUND SEPARATELY DERIVED SYSTEMS TO NEAREST EFFECTIVELY GROUNDED BUILDING STRUCTURAL STEEL. `^ U REVISION CALLOUT , EQUIP EQUIPMENT PROVIDE THE DEMOLITION FOR ALL EXISTING ELECTRICAL DEVICES/ EQUIPMENT, GENERAL NOTES: ELEVATION IDENTIFIER ETR EXISTING TO REMAIN EUH ELECTRIC UNIT HEATER EWC ELECTRIC WATER COOLER BRANCH CIRCUITING, LOW VOLTAGE CABLING, UNUSED CONDUIT, ETC., FROM WITHIN THE TENANT PREMISES. PRIOR TO DEMOLITION, COORDINATE WITH THE GENERAL 1. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. ALL POWER WIRE ON THE PREMISE SHALL BE INSTALLED IN CONDUIT. CONDUCTOR SECTION DESIGNATION: TOP LETTER INDICATES SECTION, EXIST EXISTING FACP FIRE ALARM CONTROL PANEL CONTRACTOR AND ARCHITECTURAL TO FULLY UNDERSTAND THE SCOPE AND SEQUENCE OF THE DEMOLITION. ADJUST DEMOLITION WORK TO ACCOMMODATE THE SEQUENCE DICTATED BY THE GENERAL CONTRACTOR AND ARCHITECTURAL. INSULATION SHALL BE THW, THHN OR THWN. NO ROMEX CABLES ARE ALLOWED. 2. ALL ELECTRICAL MATERIALS SHALL BE NEW AND UNUSED AND SHALL INCLUDE ALL OPTIONAL ITEMS REQUIRED FOR A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL Alp BOTTOM LETTER/NUMBER INDICATES SHEET D DETAIL DESIGNATION: TOP NUMBER INDICATES DETAIL, GND GROUND GFI GROUND FAULT CIRCUIT INTERRUPTER HOA HAND/OFF/AUTOMATIC HP HORSEPOWER HTR HEATER. J -BOX JUNCTION BOX 5. PRIOR TO DEMOLITION, COORDINATE WITH THE GENERAL CONTRACTOR AND LANDLORD TO DETERMINE IF ANY DEMOLISHED MATERIALS (SUCH AS LIGHT FIXTURES) ARE REQUIRED TO BE TURNED -OVER TO THE LANDLORD. IF SO, TURN -OVER SUCH MATERIALS AS REQUESTED. OTHERWISE PROVIDE THE PROPER DISPOSAL OF ALL DEMOLISHED MATERIALS. 6. IN THE EVENT ELECTRICAL SYSTEMS ARE WRONGLY DEMOLISHED OR BROKEN DUE TO THE DEMOLITION WORK, ELECTRICAL SUB -CONTRACTOR SHALL REPAIR SUCH SYSTEMS BEAR THE UNDERWRITER'S LABORATORIES LABEL. 3. WHEN SPACE ABOVE CEILING IS A RETURN AIR PLENUM, PLENUM NONCOMBUSTIBLE CONSTRUCTION MATERIALS SHALL BE USED ABOVE CEILING, INCLUDING EXISTING AND NEW WIRING EXCEPT INSULATION OF 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. LOW VOLTAGE OR LIMITED POWER WIRING MAY BE LABELED PLENUM RATED TYPE. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING IN ALL CONDUITS. RACEWAYS NO BOTTOM LETTER/NUMBER INDICATES SHEET ro.SHEET NOTE REFERENCE AND BOXES LTG LIGHTING LTS LOW VOLTAGELIGHTS LV AS REQUIRED TO RETURN SYSTEM TO PROPER OPERATIONAL STATE. 7. IN THE EVENT OF DEMOLISHING ENTIRE AREA CEILING GRID AND/OR LIGHT FIXTURES, ALL LIGHTING SHALL BE TEMPORARY SUSPENDED UNLESS PERMITTED BY LANDLORD. 5. ELECTRICAL BOXES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN THE INTEGRITY OF THE RATED WALL. 6. E.C. SHALL PROVIDE ALL SUPPORTS, CLIPS, POWER CONNECTIONS, TRIMS, SEISMIC Q JUNCTION BOX MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY 8. COORDINATE DEMOLITION WORK WITH GENERAL CONTRACTOR. 9. THROUGHOUT CONSTRUCTION, MAINTAIN CONTINUITY OF ALL ELECTRICAL AND LOW BRACING AND ETC., AS REQUIRED TO COMPLETE A LIGHTING SYSTEM. 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. NO SHARING PB PULL BOX XX (WHERE INDICATED, SUBCRIPT INDICATES PULL BOX NUMBER) MT EMPTY CONDUIT WITH PULLSTRING VOLTAGE WIRING AND SERVICES TO ALL ITEMS WHICH ARE REQUIRED FOR OF NEUTRAL ALLOWED. THIS SHALL APPLY FOR ALL NEW CIRCUITS AND EXISTING 0 MANHOLE MTD MOUNTED MTG HGT MOUNTING HEIGHT CONSTRUCTION OR FOR THE OPERATION OF LIFE SAFETY, OTHER ACTIVE TENANT, OR FOR BUILDING OPERATIONS. ANY REQUIRED INTERRUPTION OF THESE SERVICES SHALL BE FULLY COORDINATED WITH THE GENERAL CONTRACTOR. CIRCUITED AS REQUIRED BY CODE AND AHJ. 8. E.C. SHALL EVALUATE AND VERIFY EXISTING CONDITIONS WITH DEMOLITION AND NEW WORK PLANS PRIOR TO STARTING ANY SCOPE, AND REPORT BACK TO G.C. IF XX (WHERE INDICATED, SUBCRIPT INDICATES MANHOLE NUMBER) HH HANDHOLE N NORMAL (N) DENOTES NEW 10. ALL EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED SHALL HAVE ALL DISCREPANCIES ARE ACKNOWLEDGED AND VERIFY ACCEPTABLE SOLUTION PRIOR TO EQUIPMENT/DEVICE NL NIGHT LIGHT NF . NON-FUSED SERVING BRANCH CIRCUIT WIRING AND LOW VOLTAGE CABLING FULLY REMOVED BACK TO POINT OF SERVICE WHICH REMAINS. EXISTING CONDUIT SHALL BE FULLY REMOVED BACK TO POINT WHERE CONFLICT WITH NEW CONSTRUCTION IS FULLY ELIMINATED. DEMOLISH, ROUGH -IN, INSTALLATION AND ETC. 9. E.C. IS RESPONSIBLE TO VERIFY VOLTAGES PRIOR TO ROUGH -IN. 10. FIRE SEAL ALL FIRE WALL PENETRATIONS FOR CONDUITS WITH AN APPROVED FIRE SURFACE METAL RACEWAY NIC NOT IN CONTRACT PFB PROVIDE FOR FUTURE BREAKER. PB PULLBOX PNL PANEL PWR POWER (R) DENOTES DEVICE/ EQUIPMENT TO BE RELOCATED REC RECEPTACLE S OR SW SWITCH SIG SIGNAL SMR SURFACE METAL RACEWAY SPKR SS SAFETY SWITCH 11. ALL EXISTING PANEL -BOARDS WHICH ARE AFFECTED BY THIS PROJECT SHALL BE THOROUGHLY CLEANED. PROVIDE NEW TYPED PANEL DIRECTIONS ACCURATELY INDICATING ITEMS SERVED BY EACH CIRCUIT. 12. ALL EXISTING LOW VOLTAGE CABLING NOT REQUIRED TO REMAIN FOR OPERATION OF LIFE SAFETY, OTHER ACTIVE TENANTS OR FOR BUILDING OPERATIONS. CABLES SHALL BE REMOVED IN ACCORDANCE WITH THE N.E.C. CABLES SHALL NOT BE LEFT ABANDONED. 13. THE E.C. SHALL REMOVE EXISTING LIGHTING CONTROLS FOR THIS SPACE AND REPLACE WITH NEW SYSTEM AS SPECIFIED. E.C. SHALL PROVIDE ALL MODIFICATIONS TO EQUIPMENT, FEEDERS, AND BRANCH CIRCUITING TO ACCOMMODATE THE NEW WORK AND INSTALLATION OF NEW EQUIPMENT AND LIGHTING CONTROLS. E.C. SHALL PROVIDE ALL LIGHTING CONTROLS REQUIRED TO COMPLY WITH CODE. 14. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXTERIOR DEMOLITION SCOPE. 15. ALL CORE -DRILLING SHALL BE COORDINATED WITH THE LANDLORD AND SHALL BE PERMITTED AT THE TIME OF DAY ALLOWED BY THE LANDLORD AND G.C., IN ADDITION, SEALANT AFTER CONDUIT INSTALLATION. FIRE SEAL SHALL PROVIDE EQUAL FIRE RATING AS WALL. 11. CONTRACTOR SHALL PROVIDE AND INSTALL ALL JUNCTION AND PULL BOXES REQUIRED FOR THE INSTALLATION OF ELECTRICAL DEVICES AND EQUIPMENT WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. SIZING OF THE BOXES SHALL BE PER NEC. 12. CONTRACTOR SHALL CONSULT AND ADAPT BUILDING STANDARD DOCUMENTS/RULES AND PROVIDE IN ACCORDANCE WITH N.E.C. AND A.H.J. 13. REFER TO CONTRACTOR RULES AND REGULATIONS FOR BUILDING SPECIFIC ELECTRICAL REQUIREMENTS. CONTRACTOR SHALL ACCOMMODATE ALL BUILDING RULES AND DESIGN CRITERIA STANDARDS. 14. ALL CONDUIT ROUTING PATHS SHOWN ARE SYMBOLIC. ACTUAL PATH MAY DIFFER. PRIOR TO ROUGH -IN, COORDINATE AND VERIFY CONDUIT ROUTING PATH WITH ARCHITECT AND BUILDING OPERATION MANAGER. 15. REFER TO CONTRACTOR RULES AND REGULATIONS FOR BUILDING SPECIFIC ELECTRICAL REQUIREMENTS. RACEWAY CONCEALED IN WALL OR IN CEILING (EXPOSED IN UNFINISHED AREAS) - - RACEWAY RUN BELOW FLOOR OR BELOW GRADE -UG- UNDERGROUND DIRECT BURIED CONDUIT/RACEWAY AND/OR CIRCUITING -DB- UNDERGROUND CONCRETE ENCASED DUCTBANK CONDUIT/RACEWAY AND/OR CIRCUITING M FLEXIBLE RACEWAY -O RACEWAY INSTALLED VERTICALLY OR TURNING UP STA STATION' FLOOR X-RAY ORULTRASOUND REQUIFZED. RACEWAY TURNING DOWN TEL TELEPHONE TEMPORARY CONSTRUCTION POWER GENERAL NOTES REVISIdNS TRANS TRANSFORMER TTB TELEPHONE TERMINAL BACKBOARDS TYP ELECTRICAL PRE-BID SITE REVIEW: 1. ELECTRICAL CONTRACTOR IS TO PROVIDE ALL TEMPORARY POWER AND LIGHTING AS REQUIRED FOR USE WHEN BUILDING IS DE -ENERGIZED. -S RACEWAY CONTINUATIONS S � ttar�'S shall tea made to the scope of r°ork our prior approval of � �w E,� � k. ���� c�seon_ 9 TYPICAL UG UNDERGROUND UH UNIT HEATER 1. PRIOR TO CONSTRUCTION, VISIT PROJECT SITE AND REVIEW ALL AREAS OF THE TENANT SPACE, INCLUDING BUT NOT LIMITED TO, BACKROOMS, UNOCCUPIED SPACES AND ] RACEWAY STUB WITH BUSHING i ::: =^ Mwszo ns mil require a plan submittal arj may iir;lude additional plan review few. [ ] RACEWAY SLEEVE WITH BUSHINGS' I UON UNLESS OTHERWISE NOTED V VOLTAGE VP VA POR PROOF ABOVE CEILING AREAS TO IDENTIFY THE FOLLOWING ITEMS WHICH MAY NOT TO SHOWN ON THE PLANS: 1.1. EXISTING ELECTRICAL EQUIPMENT THAT MUST BE REMOVED AND/OR RELOCATED TO ACCOMMODATE THE NEW WORK. ONE LINE DIAGRAM W WATT OR WIRE W/ WITH WP WEATHERPROOF WT WATERTIGHT XFMR TRANSFORMER 1.2. EXISTING BRANCH CIRCUITS, ELECTRICAL FEEDERS, AND ASSOCIATED RACEWAY WHICH ARE NOT SCHEDULED FOR REMOVAL, BUT WILL REQUIRE MODIFICATION TO ACCOMMODATE THE NEW WORK. 1.3. EXISTING CABLING AND RACEWAYS FOR LOW VOLTAGE SYSTEMS WHICH ARE NOT SCHEDULED FOR REMOVAL, BUT WILL REQUIRE MODIFICATION TO ACCOMMODATE THE NEW WORK. 2. INCLUDE THE COSTS ASSOCIATED WITH: 2.1. REMOVING AND/OR RELOCATING CURRENT TRANSFORMER a_ I e 1 C CIRCUIT BREAKER, FIXED L. �- DISCONNECT SWITCH Planreview approver is to ` O /p r �,�J I rS and omi '# EXISTING ELECTRICAL EQUIPMENT TO ACCOMMODATE NEW WORK. INCLUDE COST ASSOCIATED WITH EXTENDING ASSOCIATED CONDUCTORS, CABLING AND RACEWAY TO MAINTAIN EQUIPMENTFUSED FULLY OPERATIONAL. 2.2. MODIFYING AND REPLACEMENT (WITH NEW AS REQUIRED) OF EXISTING BRANCH Approval of CorlBfrurn 8 does fio# SWITCH the violation of any /,,f, ; , ' � ' � '� ' ' "''�� of approved Field C, and, .. ,,,'„, ""S IS = M. ... , CIRCUITS AND ELECTRICAL FEEDERS TO MAINTAIN CONTINUITY OF CIRCUITS/COSTS 1 1 FUSE ASSOCIATED WITH RE -SUPPORTING AND REPLACEMENT (WITH NEW AS REQUIRED) OF ASSOCIATED RACEWAY. 2.3. 2.3. MODIFYING AND/OR REPLACEMENT (WITH NEW) OF EXISTING LOW VOLTAGE SYSTEM SYSTEM CABLING TO MAINTAIN CONTINUITY OF CABLING TO EQUIPMENT NOT SCHEDULED FOR REMOVAL. THIS SHALL INCLUDE RE -SUPPORTING AND REPLACEMENT (WITH NEW AS REQUIRED) OF CABLE AND ASSOCIATED RACEWAY. SPLICING OF LOW VOLTAGE SYSTEM CABLE IS NOT ACCEPTABLE. 3. NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY ADDITIONAL COSTS ASSOCIATED BY:. O METER --' -----� Date: e) O AMMETER City of Tui• O VOLTMETER ILDI DIV WITH EXTRA WORK AS A RESULT OF THE ELECTRICAL PRE-BID SITE REVIEW. MAIN SERVICE GROUND FAULT PROTECTION ST SHUNT TRIP REVIEWED.F®R COMPLIANCE WITH (,F GROUND FAULT PROTECTION NFPA 70 - NEC EPM ELECTRONIC POWER METER MAIN SERVICE GROUND FAULT PROTECTION DEVICE: A.CONTRACTOR SHALL PAY COST FOR QUALIFIED INDEPENDENT ELECTRICAL TESTING AGENCY TO COMPLETE ENGINEERING CALCULATION THAT DETERMINES PICK-UP SETTING AND TIME DELAY SETTING FOR THE MAIN SERVICE GFP DEVICE AT THE SERVICE SEP 0 6 2017 (TVSSI- TRANSIENT VOLTAGE SURGE SUPPRESSION t1` j Lf.A City of TU IIa DISCONNECT. THIS REQUIREMENT SHALL APPLY TO THE SERVICE DISCONNECT/GFP (PROVIDED BY LANDLORD OR TENANT CONTRACTOR) RATED GREATER THAN 800 AMPS GROUND - BUILDING DIVISION AS INDICATED ON THE PLANS. COPY OF CALCULATION INDICATING SETTINGS SHALL BE 12,241 AVAILABLE FAULT CURRENT (SYMMETRICAL) TAG SUBMITTED TO THE ARCHITECT. B. CONTRACTOR SHALL PAY COST FOR SAME ELECTRICAL TESTING AGENCY TO TEST THE OPERATION OF THE MAIN SERVICE GFP DEVICE IN ACCORDANCE WITH THE NEC. TEST SHALL ADHERE TO NETA ATS -1995 7.14 PROCEDURES. COPY OF COMPLETE TEST I TRANSFORMER 1 /E L 0613 PROCEDURE AND RESULTS SHALL BE SUBMITTED TO THE ARCHITECT. C.FOR THE COMPLETE DURATION OF CONSTRUCTION THE MAIN SERVICE GFP DEVICE SHALL BE SET AT THE MINIMUM DEVICE SETTINGS; PICK-UP OF 200 AMPS, AND TIME DELAY OF .10 SECONDS. CONTRACTOR TO NOTIFY OWNER IMMEDIATELY IF NUISANCE TRIPPING OF GFP DEVICE CREATES ANY JOB DELAYS AND REVIEW A REVISED SETTING EXIST. / DEMO. / NEW CONSTRUCTION ABBREVIATIONS FOR APPROVAL BY THE OWNER. D.AT STORE SUBSTANTIAL COMPLETION CONTRACTOR SHALL RESET THE MAIN SERVICE GFP DEVICE TO SETTINGS CALCULATED BY THE ELECTRICAL TESTING AGENCY. SETTINGS AND DATE SHALL BE ENGRAVED ON A PERMANENT LAMACOID NAMEPLATE AND ATTACHED TO THE GFP DEVICE. (E) DENOTES EXISTING EQUIPMENT/DEVICE, SCHEDULED TO REMAIN (N) DENOTES ELECTRICAL CONTRACTOR PROVIDE NEW RECEIVED (R) DENOTES RELOCATED EXISTING EQUIPMENT/DEVICE CITY OF TUKWILA (ER) DENOTES EXISTING EQUIPMENT/DEVICE TO BE RELOCATED AUG 10 2017 NOTE: SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. PERMIT CENTER co t a) O O • > 44• u L N = p O M M d• I- N N ti N- a) 0) I- IL www.jcpenney.com rI N owns 0 ca a flY0 p E J o 41111* c) X Y taN Z I. a = 2 CC IA N tin 51 O Z insitm z V) i p - U J Z o 4 Vf :i 0 W 0 a 0 0 ti o 0 0 0 0 F - 0 U w a j ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 COPYRIGHT 02016 CALLISON ELECTRICAL LEGEND AND NOTES E001 I1fflOHIII am IER SITE PLAN - ELECTRICAL ROC613 GENERAL SHEET NOTES: 1. COORDINATE EXACT LOCATION OF ALL UNDERGROUND ELECTRICAL WORK WITH CIVIL ENGINEERING DRAWINGS/DOCUMENTS, ALL OTHER SITE UTILITIES, AND SITE CONTRACTOR(S). 2. ROCK AND/OR ADVERSE SOIL CONDITIONS MAY BE PRESENT ON SITE. THE ELECTRICAL CONTRACTOR IS TO COORDINATE INSTALLATION REQUIREMENTS FOR ALL BELOW GRADE WORK WITH ANY AVAILABLE GEOTECHNICAL REPORT, AND IS TO INCLUDE IN THE BID ANY WORK RELATED TO GEOTECHNICAL CONSIDERATIONS AS IT MAY PERTAIN TO THE INSTALLATION OF ALL SITE ELECTRICAL WORK INCLUDING, BUT NOT LIMITED TO: DUCTBANKS, FOUNDATIONS/FOOTERS, CONCRETE SLABS/PADS, VAULTS, DIRECT BURIED CABLES OR CONDUITS, ETC. 3. ELECTRICAL CONTRACTOR IS TO BE RESPONSIBLE FOR ALL SURFACE RESTORATION PER THE REQUIREMENTS OF THE PROPERTY OWNER FOR ALL SURFACES AFFECTED BY THIS WORK, AND IS TO INCLUDE IN THE BID ANY WORK RELATED TO THE SAME. ALL REPLACED/REPAIRED SURFACES SHALL MATCH THAT WHICH WAS REMOVED. REVIEWEDFOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 6 2017 iy Of.Tu BUILDING DIVISION RECEIVED CITY. OF TUKWILA AUG 10 2017 PERMIT CENTER GENERAL ELECTRIC UTILITY NOTES: 1. AIR QUALITY MONITORS AND VENTILATION IS TO BE USED DURING ALL TIMES WHEN WORK IS COMPLETED INSIDE OF VAULT. 2. ELECTRICAL CONTRACTOR SHALL NOT ENTER VAULT WHILE IT IS ENERGIZED. 3. LOCAL ELECTRIC UTILITY PERSONNEL SHALL BE PRESENT WHEN WORK IS COMPLETED INSIDE OF VAULT, IF ANY LOCAL ELECTRIC UTILITY EQUIPMENT STILL EXISTS IN VAULT. 4. ELECTRICAL CONTRACTOR SHALL SCHEDULE AN ON SITE PRE -CONSTRUCTION MEETING TO DISCUSS COORDINATION AND SCHEDULE. 5. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SECONDARY CONDUIT AND CONDUCTORS FROM ELECTRIC UTILITY TRANSFORMER. 6. LOCAL ELECTRIC UTILITY WILL PROVIDE THE PRIMARY CONDUIT, PRIMARY CONDUCTORS, JUNCTION BOXES, VAULT, AND TRANSFORMER. 7. ELECTRICAL CONTRACTOR TO PROVIDE TRANSFORMER PAD, SECONDARY CONDUIT, CONDUCTORS, TRENCH, BACKFILL. GRADE INFORMATION, AND SURFACE RESTORATION. 8. CONTRACTOR TO SURVEY THE FACILITIES ONCE THEY ARE INSTALLED AND PROVIDE LOCAL ELECTRIC UTILITY THE LEGAL DESCRIPTION. LOCAL ELECTRIC UTILITY WILL THEN PLACE IT IN THEIR FORM AND SEND TO JCPENNY FOR SIGNATURE. SHEET FLAG NOTES: APPROXIMATE ROUTING OF (N) UNDERGROUND TENANT ELECTRICAL SERVICE LATERAL FEEDER FROM UTILITY TRANSFORMER SECONDARY TO TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT IS TO BE COORDINATED WITH UTILITY COMPANY AND LANDLORD (MALL) PRIOR TO INSTALLATION. ENSURE ROUTING IS SUCH THAT ALL CONFLICTS WITH EXISTING FOREIGN UNDERGROUND SYSTEMS ARE ELIMINATED. THIS IS TO INCLUDE COORDINATING THE LATERAL DEPTH AND ENCASEMENT REQUIREMENTS WITH THE UTILITY COMPANY. REVIEW SITE CONDITIONS TO DETERMINE THE ROUTING OF LATERAL TO AVOID CONFLICTS WITH BUILDING STRUCTURAL FOUNDATIONS AND FOOTINGS. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. APPROXIMATE LOCATION OF (N) TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT LOCATED WITHIN LOADING DOCK AREA. EXACT LOCATION IS TO BE COORDINATED WITH JCPENNY. EQUIPMENT MANUFACTURER IS TO BE SQUARE -D (CONTACT: DON.FOSTER@US.SCHNEIDER-ELECTRIC.COM). REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. APPROXIMATE LOCATION OF (N) UTILITY COMPANY FURNISHED AND INSTALLED UTILITY TRANSFORMER AND TRANSFORMER VAULT. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR IS TO COORDINATE WITH THE UTILITY COMPANY (PSE) AND PROVIDE ALL PHYSICAL PROTECTION VIA GUARD POSTS (BOLLARDS) AT TRANSFORMER PER UTILITY COMPANY AND AHJ REQUIREMENTS. co C) t01O > d' C% • N C p O ® to AI` AU sca 2Z rnx 0 N g J 0_ co. o c walO03 t)con.i-LL. N CD c) N I` rn cC U) O U tosil o- = C O N c a) u) ca G C W > le Na Z co F- O N O oo N E O U a) a) a 0 O N N 06 12) CD 2� N 4- CO M co 4 (15O N J F 0 U A DESIGN CONSULTANCY OF ARCADIS CALLISOIIRTKL INC. www.callisonrtkl.com 0 0 N- 0 0 CD 0 0 I— U W a ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 COPYRIGHT CI 2016 CALLISON SITE PLAN - ELECTRICAL E100 8 • •:I /\ • n tt SI d 0 a 0 2 w AAA X� (N) SPLICE BOX 56 4 PENTHOUSE FLOOR PLAN - ELECTRICAL /16" = 1'-0" Y1; (Z1 d 5.-9 5/E" HDR 62 5 57 (56 (55 O 3 SECOND FLOOR PLAN - ELECTRICAL /16" = 1'-0" (E) TRANSFORMER VAULT ROOM FLAG NOTES: ELECTRICAL CONTRACTOR TO OPEN ROOF HATCHES, TYPICAL OF (3), TO ALLOW REMOVAL OF (2) (E) UTILITY TRANSFORMERS AND (3) (E) UTILITY TRANSFORMER PADS. REPAIR ROOF HATCHES AS NECESSARY TO MAKE ALL OPERABLE AND SECURE ALL HATCHES AT COMPLETION OF PROJECT. ELECTRICAL CONTRACTOR TO PROVIDE SEPARATE PRICING BREAKOUT FOR THIS SCOPE. ELECTRICAL CONTRACTOR TO REMOVE AND DISPOSE OF (E) UTILITY TRANSFORMER PADS, TYPICAL OF (3). REMOVE ALL ASSOCIATED VIBRATION ISOLATION HARDWARE, CUT OFF AND GRIND DOWN ANY REMAINING TRIP HAZARDS. ELECTRICAL CONTRACTOR TO PROVIDE SEPARATE PRICING BREAKOUT FOR THIS SCOPE. ELECTRICAL CONTRACTOR TO REMOVE (2) EXISTING UTILITY TSCO SWITCHES. PLACE EXISTING TSCO SWITCHES AT A LOCATION COORDINATED WITH, AND DESIGNATED BY, THE UTILITY COMPANY. UTILITY COMPANY IS RESPONSIBLE FOR EXISTING TSCO SWITCHES REMOVAL. ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL (2) BOLLARDS FOR PHYSICAL PROTECTION OF (N) TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT. PROVIDE WORKING CLEARANCE AREA LINES ON THE FLOOR WITH SAFETY YELLOW PAINT. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT BOLLARD INFORMATION AND STANDARD BOLLARD INSTALLATION REQUIREMENTS. EXACT BOLLARD INSTALLATION IS TO COMPLY WITH ALL BOLLARD MANUFACTURER AND LOCAL JURISDICTIONAL REQUIREMENTS. ELECTRICAL CONTRACTOR TO REMOVE EXISTING UTILITY LOAD CENTER. CONFIRM SOURCE SERVING LOAD CENTER AND COORDINATE REMOVAL OF POWER WITH UTILITY COMPANY AND REMOVE. PLACE EXISTING UTILITY LOAD CENTER AT A LOCATION COORDINATED WITH, AND DESIGNATED BY, THE UTILITY COMPANY. UTILITY COMPANY IS RESPONSIBLE FOR EXISTING UTILITY LOAD CENTER REMOVAL. 2 FIRST FLOOR PLAN - ELECTRICAL E101 1/1'6" = 1'-0" SHEET FLAG NOTES: (N) UNDERGROUND TENANT ELECTRICAL SERVICE LATERAL FEEDER FROM (N) UTILITY TRANSFORMER SECONDARY TO (N) TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. (N) TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT LOCATED WITHIN LOADING DOCK AREA. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. [GENERAL FEEDER ROUTING SCOPE] (N) ELECTRICAL CONTRACTOR PROVIDED TENANT ELECTRICAL SERVICE FEEDER ROUTED FROM (N) TENANT SERVICE ENTRANCE EQUIPMENT TO (E) TENANT DISTRIBUTION EQUIPMENT (MDP -A) LOCATED WITHIN THE UPPER LEVEL PENTHOUSE. COORDINATE EXACT ROUTING OF FEEDER WITH JCPENNY REPRESENTATIVE AND ARCHITECTURAL. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. [BASE BID PENTHOUSE FEEDER ROUTING SCOPE] ELECTRICAL CONTRACTOR BASE BID IS TO INCLUDE ROUTING OF FEEDER, FROM LOADING DOCK AREA TO UNDERSIDE OF SECOND FLOOR CEILING AREA, TIGHT TO BUILDING EXTERIOR WALL. ROUTE FEEDER TIGHT TO UNDERSIDE OF SECOND FLOOR CEILING TO BENEATH PENTHOUSE AND THEN UP INTO PENTHOUSE TO WITHIN PENTHOUSE CEILING AREA. EXTEND FEEDER THROUGH PENTHOUSE CEILING AREA TO (E) TRANSFORMER VAULT ROOM. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. BASEMENT FLOOR PLAN ELECTRICAL 1/16" = 1'-0" 62 61 60 8 57 56 55 53 [ALTERNATE BID PLENUM FEEDER ROUTING SCOPE] ELECTRICAL CONTRACTOR ALTERNATE BID #1 IS TO INCLUDE: ROUTING OF FEEDER, FROM LOADING DOCK AREA TO UNDERSIDE OF SECOND FLOOR CEILING AREA, TIGHT TO BUILDING EXTERIOR WALL. ROUTE FEEDER TIGHT TO UNDERSIDE OF SECOND FLOOR CEILING AND EXTEND FEEDER TO BENEATH (E) TRANSFORMER VAULT ROOM AND THEN UP INTO (E) TRANSFORMER VAULT ROOM. REFER TO ELECTRICAL ONE -LINE DIAGRAMS ON SHEET E201 AND ARCHITECTURAL SECTIONS ON SHEET A300 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR IS TO REMOVE (E) UTILITY TRANSFORMERS, TYPICAL OF (2), WHICH ARE LOCATED WITHIN THE (E) TRANSFORMER VAULT ROOM. (E) TRANSFORMER REMOVAL WILL OCCUR VIA THE (E) ROOF HATCHES LOCATED AT THE (E) TRANSFORMER VAULT ROOM ROOF. PLACE (E) TRANSFORMERS ON THE GROUND AT A LOCATION COORDINATED WITH, AND DESIGNATED BY, THE UTILITY COMPANY. UTILITY COMPANY IS RESPONSIBLE FOR (E) TRANSFORMER REMOVAL. OEVIEWEEDFOR C MPLIANCE WITH NFPA 70 NEC SEP 0 6 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 10 2017 PERMIT CENTER Q 2016 CALLISON co 0) Cfl i ■ U L N COO 1.0 A n. U CO a) J E O C O Ln V CO a. N CD M M •s AN TT 1_ V) E 0 U A a) C a) 0. U .3 u. LO :0 . �N O N 4- M M Co 4 to 0 N mie-sts www.calllsonrtkl.com - J J < CDQ22,2, a 2 U O UJ Z < I— W zv� ILI Li < • UI --1 • =OY cig 1-- O i - U) 0 0 N- O O CO 0 0 I— U w 0 a ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 FLOOR PLANS - ELECTRICAL E101 ONE -LINE DIAGRAM GENERAL NOTES: 1. ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE AND CODE COMPLIANT GROUNDING SYSTEM. 2. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. 3. ALL ELECTRICAL MATERIALS ARE TO BE. NEW AND ARE TO BE OF THE NATIONAL ELECTRICAL CODE STANDARD UNLESS BETTER GRADE IS REQUIRED BY LOCAL CODE, AND IS TO BEAR THE UNDERWRITERS' LABORATORIES LABEL. 4. THE (N) TENANT ELECTRICAL SERVICE SCOPE SHOWN ON THE ONE -LINE DIAGRAM IS THE TENANT'S ELECTRICAL CONTRACTOR'S RESPONSIBILITY. RESPONSIBILITY INCLUDES COORDINATION WITH THE LOCAL UTILITY CO. AND THE OWNER. . ELECTRICAL CONTRACTOR IS TO PROVIDE EQUIPMENT RATED FOR THE AVAILABLE FAULT CURRENT. 6. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ALL (E) AND (N) ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE FOR ANY (N) ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 7. ELECTRICAL CONTRACTOR IS TO MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 8. INFORMATION OUTLINED ON ONE -LINE DIAGRAM IS BASED ON RECORD DRAWINGS. PRIOR TO BID ELECTRICAL CONTRACTOR IS TO VISIT THE SITE TO VERIFY EXACT EXISTING CONDITIONS, (N) FEEDER LENGTHS, AND (N) FEEDER ROUTING. BID IS TO INCLUDE ALL COSTS REQUIRED TO MODIFY THE EXISTING SYSTEM AS REQUIRED TO ACCOMMODATE THE (N) TENANT ELECTRICAL SERVICE, SERVICE LATERAL, AND SERVICE FEEDER. 9. ALL EQUIPMENT IS TO BE LISTED FOR USE IN THIS JURISDICTION. E,C. FURNISHED EQUIPMENT GENERAL NOTES: 1. PRIOR TO INSTALLATION, THE ELECTRICAL CONTRACTOR IS TO CONFIRM WITH THE LOCAL INSPECTOR THAT THE ARRANGEMENT OF ANY (N) TENANT EQUIPMENT IS IN ACCORDANCE WITH LOCAL CODES AND MEETS THE REQUIREMENTS OF THE INSPECTOR. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL JURISDICTION. 2. PRIOR TO INSTALLATION OF ANY (N) EQUIPMENT, ELECTRICAL SUB -CONTRACTOR IS TO SUBMIT A SHOP DRAWING OF THE EQUIPMENT LAYOUT FOR REVIEW AND APPROVAL BY THE DESIGN TEAM. 3. AT A MINIMUM, THIS SHOP DRAWINGS IS TO SHOW A FLOOR PLAN THAT ACCURATELY SHOWS THE PROPOSED LOCATIONS OF THE (N) EQUIPMENT. 4. SHOP DRAWING IS TO BE DIMENSIONED AND SCALED. ALL EQUIPMENT DIMENSIONS/SIZES ARE TO BE BASED ON APPROVED SUBMITTAL INFORMATION, INCLUDING ALL EQUIPMENT THAT IS SUPPLIED BY OTHERS. 5. THE LAYOUTS IS TO DEPICT A CODE COMPLIANT INSTALLATION THAT FITS THE AVAILABLE SPACE AS COORDINATED AND INDICATED ON THE PLANS. IN THE EVENT THERE ARE CONFLICTS WHICH PROHIBIT THE EQUIPMENT FITTING WITHIN THE SPACE INDICATED ON THE PLANS, THE SUBMITTED LAYOUT IS TO CLEARLY SHOW ADJUSTMENTS THAT ARE NEEDED. IF INSTALLATION WORK OCCURS WITHOUT APPROVED SHOP DRAWINGS, THE ELECTRICAL SUB -CONTRACTOR WILL BE FULLY RESPONSIBLE FOR CORRECTIVE ACTION AND ALL COSTS NECESSARY FOR A COMPLETE AND COORDINATED INSTALLATION, FREE OF CONFLICTS WITH ANY (E) SYSTEMS. CONNECTION TO METAL WATER SERVICE. SEE$ NOTE #4 CONNECTION TO STRUCTURAL STEEL OF BUILDING. SEE NOTE #3 EXOTHERMIC WELD (TYPICAL OF 3) MAIN SERVICE EQUIPMENT EQUIPMENT GROUND BUS BONDING JUMPER NEUTRAL BUS L_ #2 COPPER #2 COPPER #2 COPPER �10' MIN. #3/0 COPPER #3/0 COPPER MGB - LOCATED NEXT TO MAIN SERVICE EQUIPMENT. SEE NOTE #1 (3) 3/4" COPPER -CLAD 10' LONG GROUND RODS DETAIL NOTES: 1. MGB (MAIN GROUND BAR) SHALL BE ERICO #EGBA14412NN (INCLUDES MOUNTING BRACKET AND INSULATORS) OR EQUAL BY PANDUIT. US PRESSURE CONNECTORS (LISTED FOR GROUNDING) TO CONNECT COPPER WIRE TO MGB. 2. THE REBAR MUST NOT BE LESS THAN 20 FEET IN LENGTH AND 1/2" IN DIAMETER OR 20 FEET OR MORE OF BARE COPPER CONDUCTOR NOT SMALLER THAN NO.4 IN THE BOTTOM OF THE FOOTER PER NEC SECTION 250.52. PROVIDED UNDER SHELL CONTRACT. (E) 2000A BUS WITH HALF NEUTRAL TO ADJACENT "MDP -B" 5 (E) MAIN DISTRIBUTION PANEL "MDP -A". 480/277 VAC (E) 4000A BUS WITH HALF NEUTRAL (E) (E) E (E) MAIN SWITCH (E) INCOMING SECTION SERVICE SECTION 5 (E) 2000A BUS WITH HALF NEUTRAL TO ADJACENT "MDP -B" 5 X w LI/ ZD Z w I- Z z Lj LU (E) 6000A BUS WITH HALF NEUTRAL (E) UTILITY CT'S AND METERS. METERS TO BE Lu • REMOVED 2 00 1- ELECTRICAL ONE -LINE DIA NTS (E) MAIN DISTRIBUTION PANEL "MDP -A". 480/277 VAC -- � OE®OE0 (E) 4000A BUS WITH HALF NEUTRAL -. A. X 0 xs GENERAL PROJECT SCOPE NOTES: SHEET FLAG NOTES: 1. PROJECT SCOPE INCLUDES: REPLACING THE EXISTING UTILITY TRANSFORMERS WITH NEW. THIS WILL BE ACCOMPLISHED BY INSTALLING A COMPLETE NEW TENANT SERVICE FROM THE NEW TRANSFORMER LOCATION (BUILDING EXTERIOR AT GRADE) TO THE EXISTING TENANT DISTRIBUTION EQUIPMENT LOCATION (UPPER LEVEL PENTHOUSE). AT A TIME AS COORDINATED WITH JCPENNY, THE EXISTING SERVICE WILL BE DISCONNECTED AND THE NEW SERVICE WILL BE CONNECTED TO THE EXISTING TENANT DISTRIBUTION EQUIPMENT. TENANT ELECTRICAL CONTRACTOR IS TO COORDINATE THE TIMING OF THIS SERVICE "SWITCHOVER" WITH THE DESIGN TEAM AND JCPENNY REPRESENTATIVE PRIOR TO COMMENCEMENT OF WORK. 2. EXISTING UTILITY TRANSFORMERS LOCATED WITHIN THE EXISTING TRANSFORMER VAULT ROOM (UPPER LEVEL ADJACENT TO THE PENTHOUSE) WILL REMAIN ENERGIZED UNTIL SUCH TIME THAT THE SERVICE "SWITCHOVER" TAKES PLACE. ALL TENANT ELECTRICAL CONTRACTOR WORK WHICH TAKES PLACE WITHIN THIS ROOM IS TO BE COORDINATED WITH THE UTILITY COMPANY (PSE) AND MAY INCLUDE THE REQUIREMENT FOR UTILITY PERSONNEL TO BE PRESENT DURING ANY WORK WITHIN THIS ROOM. 0 x UTILITY TRANSFORMERS TO BE REMOVED BY UTILITY CO. M - EXISTING AND DEMOLITION (E) MAIN SWITCH i (E) INCOMING SECTION SERVICE SECTION 3. STRUCTURAL STEEL MUST BE USED AS A GROUNDING ELECTRODE WHERE IT IS EFFECTIVELY GROUNDED PER NEC SECTION 250.52. PROVIDED UNDER SHELL CONTRACT. 4. WHERE A WATER METER OR FILTERING EQUIPMENT IS IN THIS METAL WATER PIPING SYSTEM, IT MUST BE BONDED AROUND TO MAINTAIN CONTINUITY EVEN IF THE WATER METER OR FILTER IS REMOVED PER NEC SECTION 250.52. PROVIDED UNDER SHELL CONTRACT. GENERAL NOTES: 1. IF THE GROUNDING SYSTEM OUTLINED ABOVE DOES NOT MEET ALL REQUIREMENTS TO COMPLY WITH THE ADOPTED JURISDICTIONAL CODES AND ORDINANCES, E.C. SHALL PROVIDE ALL ADDITIONAL EQUIPMENT, WORK, DEVICES, MODIFICATIONS, CONDUIT AND WIRING, COORDINATION, ETC. TO ACHIEVE COMPLIANCE. 3 ELECTRICAL SERVICE GROUNDING DETAIL NTS w Lu Q z 0 LU= Z ww (N) SPLICE BOX - TENANT ELECTRICAL CONTRACTOR IS TO PROVIDE THE TENANT ELECTRICAL SERVICE SECONDARY FEEDERS FROM TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT TO THE (E) TENANT INTERIOR ELECTRICAL GEAR (MDP -A). (4) 4" CONDUITS WITH 4#500 MCM CU(90°), 1#4/0 GND CU IN EACH CONDUIT. REFER TO PLANS FOR PROPOSED ROUTING. APPROXIMATE DISTANCE IS 235'. (E) 6000A BUS WITH HALF NEUTRAL (E) UTILITY CT'S w 00 J w 2 O 0 CO Q� • J D w> (N) 1#3/0 CU GROUNDING ELECTRODE - (N) TENANT ELECTRICAL CONTRACTOR PROVIDED AND INSTALLED NEMA 1 TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT. 1600A, 480/277 VAC. 35k A.I.C. EQUIPMENT MANUFACTURER TO BE SQUARE -D MAIN SWITCH SECTION INCOMING SERVICE AND METER SECTION 2 ELECTRICAL ONE -LINE DIAGRAM - NEW CONSTRUCTION E201 NTS ELECTRICAL SERVICE LOAD SUMMARY HIGH kW DEMAND LOAD PER PSE METER NUMBER 2003556786 = 817.6 kW EXISTING DEMAND LOAD PER NEC 220.87 (x1.25) 1231 AMPS LOAD SUMMARY STATEMENT: 1. THE PROJECT SCOPE INCLUDES THE REMOVAL, AND REPLACEMENT WITH NEW, OF THE EXISTING UTILITY TRANSFORMERS (PSE). 2. THERE ARE NO NEW LOADS BEING ADDED UNDER THE SCOPE OF THIS PROJECT. 3. BASED ON THE UTILITY COMPANY'S 12 MONTH DEMAND HISTORY, THE ACTUAL TENANT PEAK DEMAND LOAD IS 817.6 kW. 4. PER NEC 220.87, 125% HAS BEEN ADDED TO THE PEAK DEMAND LOAD SUMMARY ABOVE. 5. THE EXISTING TENANT DISTRIBUTION EQUIPMENT, WHICH IS SCHEDULED TO REMAIN, IS RATED FOR A HIGHER DESIGN DEMAND LOAD THAN THAT WHICH IS ACTUALLY USED. 6. UNDER THE SCOPE OF THIS PROJECT, THE NEW TENANT SERVICE ENTRANCE EQUIPMENT RATING AND ASSOCIATED NEW TENANT SERVICE LATERAL RATING AND DOWNSTREAM SERVICE FEEDER RATING HAVE BEEN SIZED TO ACCOMMODATE THE ACTUAL TENANT DEMAND LOAD USE BASED ON THE 12 MONTH DEMAND HISTORY. LL L S O a � Y z 00 zO 0�z m0 w (E) BUILDING EXTERIOR (E) 1500kVA UTILITY TRANSFORMER A.F.0 VALUE: 34k (E) UTILITY I TRANSFORMER VAULT BY UTILITY CO. (E) UTILITY TRANSFORMER PRIMARY BY UTILITY CO. FAULT CURRENT STUDY ALL EQUIPMENT TO BE FULLY RATED NAME VOLTAGE L -L DISTANCE GAUGE # OF SETS AVAILABLE RMS DUTIES (A) 3 PHASE _ . EXISTING UTILITY TRANSFORMER _...^..._. ...__FSCONDARY NEW UTILITY TRANSFORMER SECONDARY NEW SERVICE ENTRANCE EQUIPMENT 480 480 - 480 90' 600 MCM CU EXISTING DISTRIBUTION EQUIPMENT "MDP A' 480 235' 600 MCM CU NOTES: 4 34,000 34,000 30,100 23,162 1. NEW EQUIPMENT IS TO HAVE MINIMUM. BRACING AND INTERUPT RATINGS GREATER THAN THE AVAILABLE THREE-PHASE FAULT CURRENT INDICATED ABOVE. 2. ALL DISCONNECTS/BREAKERS ARE TO BE FULLY RATED FOR THE AVAILABLE FAULT CURRENT. SUBMIT DOCUMENTATION INDICATING THE RATING OF DEVICES. (E) 4000A LOAD -BREAK SWITCH. 480V/277V, 3PH., WITH 4000A FUSES WITH SHUNT TRIPPING DEVICE. (E) SERVICE BUS DUCTS - (2) 3000A, 3PH., HALF NEUTRAL, 480V/277V PROJECTING TWO FEET INTO (E) TRANSFORMER VAULT ROOM. UTILITY COMPANY TO DISCONNECT AND REMOVE EXISTING PRIMARY UTILITY FEEDER CONDUCTORS WITHIN TRANSFORMER VAULT ROOM. THIS SCOPE TO BE PERFORMED BY UTILITY COMPANY AND IS SHOWN FOR REFERENCE ONLY. CLEAN ,INSPECT, AND TORQUE CONNECTIONS OF EXISTING BUS DUCT. (E) UTILITY TRANSFORMERS TO BE DISCONNECTED BY UTILITY COMPANY AND REMOVED BY ELECTRICAL CONTRACTOR. REFER TO FLAG NOTE #6, SHEET E101 FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR IS TO DISCONNECT AND REMOVE EXISTING SECONDARY UTILITY FEEDER CONDUCTORS BETWEEN THE (E) BUS DUCT AND (E) UTILITY TRANSFORMERS WITHIN TRANSFORMER VAULT ROOM. ELECTRICAL CONTRACTOR TO PROVIDE SEPARATE PRICING BREAKOUT FOR THIS SCOPE. PROVIDE GROUNDING ELECTRODE SYSTEM. SEE DETAIL #3 THIS SHEET. NEW 1500kVA UTILITY TRANSFORMER AND PAD TO BE PROVIDED BY THE UTILITY COMPANY. PER NEC, MAXIMUM UNPROTECTED (NON-ENCASED) SERVICE LATERAL LENGTH, UPSTREAM FROM THE SERVICE ENTRANCE EQUIPMENT, IS TO BE NO GREATER THAN 15'. TENANT ELECTRICAL CONTRACTOR IS TO COORDINATE WITH THE UTILITY COMPANY AND EXTEND THE UNDERGROUND TENANT ELECTRICAL SERVICE LATERAL CONDUITS, ENCASED IN CONCRETE, FROM 5' AT BUILDING EXTERIOR TO THE TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT. ELECTRICAL CONTRACTOR IS TO PROVIDE THE LATERAL CONDUCTORS FROM THE UTILITY TRANSFORMER TO THE TENANT EQUIPMENT. COORDINATE TERMINATION OF CONDUCTORS AT TRANSFORMER SECONDARY WITH UTILITY COMPANY. LATERAL CONSISTS OF (4) 4" CONDUITS WITH 4#500 MCM CU(90°), 1#4/0 GND CU IN EACH CONDUIT. PROVIDE WITH (4) 4" CONDUIT(S) AS SPARE. SPARE CONDUIT(S) ARE TO BE STUBBED UP AND CUT FLUSH WITH FLOOR. APPROXIMATE COMPLETE LATERAL DISTANCE IS 90'. COORDINATE ALL LATERAL AND ENCASEMENT REQUIREMENTS WITH UTILITY COMPANY. TENANT ELECTRICAL CONTRACTOR IS TO COORDINATE WITH THE UTILITY COMPANY AND PROVIDE A (N) TENANT UTILITY METER AND PHASE CLAMP PROVISIONS PRE-INSTALLED FOR FUTURE CUSTOMER METER. CONDUIT INSTALLED BY THE TENANT ELECTRICAL CONTRACTOR IS TO BE FURNISHED WITH ALL NEC CODE COMPLIANT BEND RADIUSES. ELECTRICAL CONTRACTOR IS ALSO TO PROVIDE ALL PULL BOXES AND RACEWAYS AS REQUIRED TO ACCOMMODATE THE ROUTING OF THE (N) TENANT SERVICE AS INDICATED WITHIN THESE CONSTRUCTION DOCUMENTS OR AS REQUIRED. TENANT ELECTRICAL CONTRACTOR IS TO REMOVE EXISTING SERVICE GROUNDING SYSTEM. ELECTRICAL CONTRACTOR IS TO PROVIDE NEW MAIN SERVICE GROUND FAULT PROTECTION DEVICE (GFI) AT SERVICE. PROVIDE GFI ADJUSTMENT SETTINGS PER "MAIN SERVICE GROUND FAULT PROTECTION" NOTES ON SHEET E001 FOR REQUIREMENTS AND ADDITIONAL INFORMATION. PROVIDE ARC FLASH STUDY AND LABEL EQUIPMENT PER CODE. COORDINATE WITH BUS DUCT MANUFACTURER AND PROVIDE SPLICE BOX, OR OTHER MEANS FOR CONTAINING CONDUCTORS, AND PROPERLY TERMINATING TO BUS DUCT IN ACCORDANCE WITH BUS DUCT MANUFACTURER REQUIREMENTS. MODIFY OR REPLACE BUS DUCT WITH NEW IF NECESSARY. ELECTRICAL CONTRACTOR IS TO SCHEDULE WORK, AS COORDINATED WITH JCPENNY REPRESENTATIVE AND UTILITY COMPANY, SO AS TO MINIMIZE DOWNTIME TO ELECTRICAL SYSTEM DURING TENANT SERVICE "SWITCHOVER". "SWITCHOVER IS TO OCCUR DURING STORE OFF HOURS (SUNDAY NIGHT). ELECTRICAL CONTRACTOR TO PROVIDE TENANT ELECTRICAL SERVICE ENTRANCE EQUIPMENT MOUNTING AND LEVELING PAD. ELECTRICAL CONTRACTOR TO COORDINATE PENETRATIONS THROUGH EXISTING BUILDING STRUCTURAL WITH GC AND PROVIDE ALL WATERPROOFING AT PENETRATIONS AS REQUIRED PER CODE. DENOTES 5 FEET FROM BUILDING EXTERIOR. UTILITY COMPANY TO PROVIDE UNDERGROUND TENANT ELECTRICAL SERVICE LATERAL CONDUITS FROM UTILITY TRANSFORMER TO 5 FEET FROM BUILDING EXTERIOR. REFER TO NOTE #10 FOR ADDITIONAL INFORMATION. EQUIPMENT AND SERVICE BREAKER TO BE RATED AT 100%. REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC SEP 0 6 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 10 2011 PERMIT CENTER COPYRIGHT 02016 CALLISON 0 0 0 N co M M M N ECtif` 0 carnrn cpenney.corn ton V = O N 5 CD0 Cr) C W > N < Z I-- O O N 4 Ad 4 (6 O N 4- CO Co 4 O N 4.0 A DESIGN CONSULTANCY OF ARCADIS t.) . 1 0 J J 4 0 www.callisonrtkl.com J J J < tOQ2omo to rt zU ILI W = i<ss OI..._ cin D O N(n 0 0 0 0 0 0 H 0 w 0 0: 0 ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 ELECTRICAL ONE -LINE DIAGRAMS E201 ELECTRICAL SPECIFICATIONS SECTION 26050: GENERAL ELECTRICAL The Drawings, General Conditions, Supplementary Conditions, and Division 1 apply to work under this Section. PART 1 GENERAL: 1.01 DESCRIPTION A. General: Furnish all labor, materials, apparatus, tools, equipment, transportation, temporary construction and special or occasional services as required to make a complete working electrical installation, as shown on the drawings or described in these specifications. B. Work included: 1. N/A 2. Grounding. 3. N/A 4. Provide panelboards and overcurrent devices. 5. N/A 6. N/A 7. N/A 8. N/A 9. N/A 10. N/A 11. Demolition and removals. 12. N/A 13. N/A 14. N/A 15. Demolition 16. Provide all work and modifications to comply with code and the requirements of the authority having jurisdiction. 1.02 CODES AND STANDARDS: A. Specific 1. Comply with all applicable codes and Jurisdictional/Landlord requirements. 1.03 2. Equipment and materials specified under this division shall conform to the following standards where applicable. a. UL Underwriters' Laboratories. b. ASTM American Society for Testing Materials. c. CBM Certified Ballast Manufacturers. d. ANSI American National Standards. Institute. e. NEMA National Electrical Manufacturers Association DRAWINGS: A. Layout: General layout shown on the drawings is diagrammatic. Coordinate with Architectural and other Trades/Owner Vendors for exact location of devices/equipment. B. Accuracy: 1. Drawings for the work under this Section are diagrammatic and complete details of the building which affect the electrical installation are not shown. Coordinate with drawings of all other trades. 2. Contractor shall verify lines, levels and dimensions shown on the Drawings and shall be responsible for the accuracy of the setting out of work and for its strict conformance with existing conditions at the site. 1.04 SUBSTITUTIONS: Substitutions of specified devices and equipment shall not be allowed. 1.05 SUBMITTALS: A. General: Refer to the General Conditions, Supplementary General Conditions and Division 1 for requirements. B. Format: Furnish submittal data in PDF format with a table of contents listing in order of specification section and paragraph number. C. Submittals shall consist of detailed shop drawings, specifications, catalog "cuts" and data sheets containing physical and dimensioned information, performance data, electrical characteristics, materials used in fabrication, material finish and those optional accessories which are included and those which are excluded. D. Each submittal shall be thoroughly reviewed by the Contractor. The cover letter accompanying submittal letter shall list in full the items and data submitted and shall contain a statement acknowledging that the Contractor has performed a detailed review of the submittal documents prior to submission. Failure to comply with this requirement shall constitute grounds for retum of data for resubmission without review. E. Contractor agrees that Shop Drawing submittals processed by the engineer are not change orders, that the purpose of Shop Drawing submittals by the Contractor is to demonstrate to the engineer that the Contractor understands the design concept, that he demonstrates his understanding by indicating which equipment and material he intends to furnish and install and by detailing the fabrication and installation methods he intends to use. 1.06 PRODUCT DELIVERY, STORAGE AND HANDLING: Equipment and materials shall be properly stored and adequately protected and carefully handled to prevent damage before and during installation. Equipment and materials shall be handled, stored, and protected in accordance with the manufacturers's recommendations and as approved by the Owner's Representative. Electrical conduit shall be stored to provide protection from the weather and accidental damage. Plastic conduit shall be stored on even supports and in locations not subject to direct sun rays or excessive heat. Cables shall be sealed, stored and handled carefully to avoid damage to the outer covering or insulation and damage from moisture and weather. Damaged or defective items, in the opinion of the Owner's Representative, shall be replaced with new items at the expense of the contractor. 1.07 PERMITS AND FEES: Provide, procure and pay for all permits, licenses and fees required to carry on and complete the work. PART 2 PART 3 3.01 PRODUCTS (Not Applicable) EXECUTION: TESTS: A. Tests shall be conducted during the construction period and at completion to determine conformity with applicable Codes and with these Specifications. Tests shall be performed in the presence of the Architect and shall include, but are not limited to, the following: 1. Insulation Resistance: Perform 500 -volt D.C. tests for one minute on all feeder conductors, including the neutral, and make a typed record of all readings to be included in the maintenance instructions. Repair or replace circuits showing less than 40 megohms resistance to ground. Make tests using Biddle Insulation Resistance Megger, or equal. 2. Ground Resistance: Test ground resistance per IEEE Standard No. 81. 3. Circuits Continuity: Test all feeder and branch for continuity. Test all neutrals for improper grounds. 4. N/A 5. N/A 6. Product Failure: Any products which fail during the tests or are ruled unsatisfactory by the Owner's Representative shall be replaced, repaired, or corrected as prescribed by the Owner's Representative at the expense of the Contractor. Tests shall be performed after repairs, replacements or corrections until satisfactory performance is demonstrated. 7. Physical Inspection of Electrical Equipment and Cables: Inspection shall be made of all equipment to insure proper assembly and construction. 3.02 INSTRUCTIONS AND MANUALS A. N/A B. At the time of completion, an adequate period shall be allotted by the contractor for instruction of building operating and maintenance personnel in the use of all systems. All personnel shall be instructed at one time, the Contractor making all necessary arrangements with manufacturers's representatives. The equipment manufacturer shall provide product literature and application guides for the Users' reference. C. Costs, if any, for the above service shall be paid by the Contractor. 3.03 PROJECT RECORD DOCUMENTS (AS -BUILT) A. Provide Project Record Drawings and Specifications as required by other Sections of Specifications and as required herein. Such drawings shall fully represent installed conditions including actual location of outlets, correct conduit and wire sizing as well as routing, revised fixture scheduling listing the manufacturer and products actually installed. B. All changes to drawings shall be made by qualified draftspersons to match existing line work and lettering as closely as possible. 3.04 WORKMANSHIP A. Preparation, handling and installation shall be in accordance with manufacturer's written instructions and technical data particular to the product specified and/or approved except as otherwise specified. Coordinate work and cooperate with other in furnishing and placing this work. Work to approved shopdrawings for work by others and to field measurements as necessary to properly fit the work. B. Conform to the National Electrical Contractor's Association Standard of Installation for general installation practice. 3.05 SCHEDULE OF WORK: Arrange work to conform to the schedule which has been established for the progress of the work. Advise regarding shipping schedule of major equipment. 3.06 SUPERVISION: Contractor shall personally or through an authorized and competent representative constantly supervise the work from beginning to completion and, within reason, keep the same workmen and foreman on the project throughout the project duration. 3.07 PROTECTION: Keep conduits, junction boxes, outlet boxes, and other openings closed to prevent entry of foreign matter. Cover fixtures, equipment and apparatus and protect against dirt, paint, water, chemical or mechanical damage, before and during construction period. Restore to original condition any fixture, apparatus, or equipment damaged prior to final acceptance. Protect bright finished surfaces and similar items until in service. No rust or damage will be permitted. 3.08 SPECIAL TOOLS: All special tools for proper operation and maintenance of the equipment provided under this section shall be delivered to the Owner's representative. 3.09 CUTTING AND PATCHING A. Install all required sleeves, forms and insets before walls or partition are built. Cutting and patching of walls, partitions, ceilings and floor necessary for reception of work. caused by failure to provide or properly located sleeves, forms and insets, incorrect location of work or failure to cooperate with other trades, shall be done at expense of trade responsible. B. No cutting of finished or structural work may be done without acceptance. When necessary to have finished material or structural work cut, furnish necessary drawings to trade whose materials are out to be cut. 3.10 CLEARANCES: Provide working clearance in front of, in back of, and to sides for all electrical equipment as required by National Electrical Code Article 110. 3.11 DEMOLITION: Demolition and removal of existing electrical services to the existing tenant space to be by the Contractor. 3.12 ACCESS PANEL A. Elec. contractor shall provide all access panels required for code required access to electrical devices and junction boxes. B. Access panels shall not be allowed in Sales Area ceiling or walls. Devices and equipment that normally would be concealed from view shall be located at normally accessible areas such as above ceiling, near HVAC diffusers or in back rooms in accessible ceiling areas. 3.13 DEMOLITION AND REMOVAL OF EXISTING SYSTEMS A. No existing electrical system components and raceways that are unusable or non-functioning, or rendered as such due to the project scope of work, shall be abandoned. B. Electrical contractor shall coordinate with the owner and owner's representatives to determine the exact existing electrical system components and raceways demolition and removal scope prior to Bid and commencement of work and include all associated costs within Bid. END OF SECTION SECTION 26100: BASIC MATERIALS AND METHODS The General Conditions, Supplementary Conditions, and Division 1 apply to work under this Section. PART 1 GENERAL 1.01 DESCRIPTION A. Work specified in this section encompasses products, assemblies and basic installation methods required for electrical project systems specified under this Division and includes, but is not limited to: 1. Conduit, raceways, and fittings. 2. Wire and cables. 3. Wire connections and devices. 4. Outlet boxes. 5. Pull and junction boxes. 6. Overcurrent protective devices. 7. Panelboards and associated equipment 1.01 SUBMITTALS A. Submit in conformance with the requirements of Section 16050 the following items: 1. Overcurrent protective devices. 2. Raceways. 3. Panelboards PART 2 PRODUCTS 2.01 CONDUIT AND FITTINGS A. Rigid Steel Conduit 1. Conduit, rigid steel: full weight, threaded, hot -dip galvanized, inside enameled, conforming to ANSI C80.1. 2. Three-piece couplings: electroplated, cast malleable iron. Efcor 165 series, O.Z./Gedney 4-50 series or equal. 3. Threadless couplings: electroplated, cast malleable iron, with integral conduit stop. Efcor 1760. 4. Threadless connectors: electroplated, cast malleable iron, on threaded male hub plastic insulated throat rated 90 degrees C minimum. Efcor 1750B series, O.Z./Gedney 31-050 1T series or equal. 5. Insulated bushings: threaded polypropylene or thermosetting phenolic rated 150 degrees C minimum. 6. Insulated grounding bushings: threaded cast malleable iron body with insulated throat and steel, "lay -in" ground lug with compression screw. O.Z./Gedney BLG series, Thomas & Betts 3870 series or equal. 7. Insulated metallic bushings: threaded cast malleable iron body with plastic insulated throat rated 105 degrees C. O.Z./Gedney Type B, Thomas & Betts 1222 series or equal. B. Electrical Metallic Tubing (EMT) 1. Conduit: Shall be formed of cold rolled strip steel, electrical resistance welded continuously along the longitudinal seam and hot -dip galvanized after fabrication. Conduit shall conform to ANSI C80.3 specifications and shall meet U.L. requirements. 2. Couplings: Electroplated, cast malleable iron, gland compression type, U.L. listed rain and concrete tight through 1-1/4 inch trade size, O.Z./Gedney 6050W series, Efcor 760 series or equal. Set screw type couplings may be used in dry locations, O.Z./Gedney 5050 series or equal. 3. Connectors: Gland compression type with cast malleable iron body with male hub and insulated plastic throat 150 degrees C. temperature rated. O.Z./Gedney 4050 series or equal. C. Flexible Metallic Conduit 1. Conduit: Shall be fabricated in continuous lengths from galvanized steel strip, spirally wound and formed to provide an interlocking design. 6' MAX. LENGTH Flexible conduit is not permitted in walls. 2. Fittings: Connectors shall be made of the screw clamp with cast malleable iron bodies and threaded male hubs with insulated throats. 3. Flexible conduit shall only be allowed in the lengths and for applications as allowed by the jurisdiction and Landlord. Contractor shall be responsible for correcting installation that is not in compliance with the jurisdictional and Landlord requirements D. Liquid Tight Flexible Metallic Conduit 1. Conduit: Anaconda Type U.A., Coleman Type Uxt1 or equal. 2. Fittings: Connector body and gland nut shall be of cadmium plated cast malleable iron, with insulated throat, MAX. 24", T & B 5331 series, O.Z./Gedney 4Q -38-1T series, or equal. E. Minimum acceptable conduit size shall be 3/4 inch. F. 2.02 A. N/A WIRE AND CABLE General 1. Acceptable manufacturers: General Electric Co., Rome Cable, Southwire, Triangle, PWC Inc., or equal. 2. Conductor material: All wire and cable shall be insulated copper conductors for all wire sizes. Aluminum wire and cable shall not be used. 3. Insulation: Insulation shall be THWN-THHN for wire sizes through size 1/0 AWG. For larger wire sizes insulation shall be THWN, XHHW, THW or as required to suit application. 4. Fixture wire: Type AF. 5. Minimum conductor size: Power and lighting branch circuits: #12 AWG. Signal and control circuits under 100 volts: #14 AWG. Any 120V/20A circuits over 75 linear feet must be: #10 AWG. 6. Color code. Color code all conductors in accord with NEC as follows: Phase A Phase B Phase C Neutral 2.03 N/A 2.04 N/A 120/208V Black Red Blue White 2.05 N/A 2.06 N/A 2.07 N/A 2.08 PANELBOARDS A. Ratings: See panel schedules. B. C. D. 277/480V Brown Orange Yellow Gray Finish: All painted steel work shall be treated with a primer coat and finish coat of the manufacturer's standard gray color or ANSI 61. Electrical Contractor shall provide all panelboards as indicated on the plans. Panelboards shall be keyed alike, and arrangened to fit in the space indicated on the plans E. Bussing 1. Bussing is to be rectangular cross section full length silver-plated copper, rated. 1000 Amperes/sq. 2. Each panelboard shall be equipped with a ground bus secured to the interior of the enclosure. The bus shall be equal to the panelboard neutral bus and shall have a separate lug for each ground conductor. Not more than one conductor shall be installed per lug. 3. Each isolated ground panelboard shall be equipped with a isolated ground bus secured to the interior of panelboard with a separate isolated ground wire (sized per the NEC) run back to the grounding electrode F. Manufacturer shall be Square D G. Prior to ordering, the Electrical Contractor shall confirm with the serving Utility and the Landlord, the available fault current level at the tenant disconnect. Tenant panelboards shall be ordered with an AIC rating greater than the available fault current level. If contractor does not confirm fault current level, equipment fully be fully rated at 65k AIC minimum. 2.09 PROTECTIVE DEVICES A. Circuit Breakers: Molded case, bolt -on, thermal magnetic type, 40 degrees C. ambient temperature compensated, fixed mounting, with quick -make and quick -break switching mechanism mechanically trip -free from the operating handle. B. Ratings: Refer to drawings and panel schedules for trip frame and poles required. Equipment shall be. fully rated based on available fault current level. 2.10 ELECTRICAL SUPPORTING DEVICES A. Conduit Straps: Hot -dip galvanized, cast malleable iron, one hole type strap with cast clamp -backs and spacers as required. O.Z./Gedney #14-50G strap and #141G spacer, Refcor #231 strap and #131 spacer, or equal. B. Construction Channel: 1-1/2 inch by 1-1/2 inch 12 gauge galvanized steel channel with 17/32 inch diameter bolt holes, 1-1/2 inches on center, in base of the channel. Kindorf 905 series, Unistrut P -1000 -HS, or equal. C. Fasteners (General): Wood screws for fastening to wood. Machine screws for fastening to steel. Toggle bolts for fastening to hollow concrete block, gypsum board or plaster wall. Expansion anchors for attachments to pre -poured concrete. 2.11 IDENTIFYING DEVICES A. Panelboard Directories: Shall be typewritten, arranged in numerical order and shall show the number of the circuit is indicated. The room numbers used shall be verified with the Owner and shall not necessarily be those used in the drawings. Mount directories in a 6" x 8" metal frame under plexiglass inside each panelboard. B. Wire & Terminal Markers: Self -adhering, pre-printed vinyl with self -laminating wrap ground strip Brady B191 series, Thomas & Betts WSl series, or equal. 2.12 N/A 2.13 GROUNDING A. Enclosures of equipment, raceways, and fixtures shall be permanently and effectively grounded. Provide code -sized, (unless otherwise indicated) copper, insulated green equipment ground with all branch and feeder circuit runs. Equipment ground shall originate at panelboard ground bus and shall be bonded to all switch and receptacle boxes and electrical equipment enclosures. B. Building services shall be grounded to building steel and to cold metallic water piping. C. Isolated ground conductors shall terminate on isolated ground bus and receptacle isolated ground lugs only. PART 3 EXECUTION 3.01 CONDUIT AND RACEWAY APPLICATIONS A. Rigid Steel Conduit: For all exposed and U/G conduit exposed to mechanical damage. Minimum size is 3/4". B. Electrical Metallic Tubing (EMT): Interior power and lighting branch circuits where run concealed above suspended ceiling, in stud walls, furred spaces, and where not exposed to mechanical damage, or above 6' from floor. 3.02 CONDUIT INSTALLATION A. B. General 1. Conduit system shall be concealed unless exposed work is clearly called for on drawings. 2. Conduits shall be tightly covered and well protected during construction using metallic bushings and bushing "pennies" to seal open ends. 3. In all empty conduits or ducts, install a 200 -pound tensile strength polyethylene pulling rope. 4. Conduit systems shall be electrically continuous throughout. Install code size, insulated, copper, green grounding conductor in all conduit runs pulled with phase and netural conductors. Layout 1. Locations of conduit runs shall be planned in advance of the installation and coordinated with the ductwork, plumbing, ceiling and wall construction in the same areas and shall not unnecessarily cross other conduits or pipe, nor prevent removal of ceiling or tiles or panels, nor block access to mechanical or electrical equipment. 2. Where practical, install conduits in groups, in parallel, for vertical and horizontal runs and at elevations that avoid unnecessary offsets. 3. Exposed conduit shall be run parallel or at right angles to the centerlines of columns and beams. 4. Conduits shall not be placed closer than 12 inches from a parallel hot water or steam line or 3 inches from such lines crossing, perpendicular to the runs. C. Supports D. 1. All raceway systems shall be secured to the building structures using specified fasteners, clamps and hangers spaced according to code requirements. 2. Support single runs of conduit using one hole pipe straps. Where run horizontally on walls in damp or wet location, install "clamp -backs" to space conduit off the surface. 3. Multiple conduit runs shall be supported using"trapeze" hangers fabricated from specified construction channel, mounted to 3/8 inch diameter, threaded steel rods secured to building structures., Fasten conduit to construction channel with standard one hole pipe clamps or the equivalent. Termination and Joints 1. Raceways shall be joined using specified coupling or transition couplings where dissimilar raceway systems are joined. 2. Conduits shall be securely fastened to cabinets, boxes and gutters using two locknuts and an insulating bushing or specified insulated connectors. Install grounding bushings or bonding jumpers on all conduits terminating at concentric knockouts. 3. Conduit terminations exposed at weatherproof enclosures and cast outlet boxes shall be made watertight using specified connectors and hubs. 4. Install expansion couplings where any conduit crosses a building separation or expansion joint. E. Penetrations 1. All floor penetrations shall be sealed water -tight. Maintain fire rating as required. 2. Fire -safe all rated wall penetrations using 3M listed fire-safing sealants and assemblies. 3.03 CABLE AND WIRE INSTALLATION A. General 1. RECEIVED CITY OF TUKWILA AU6 10 2017 PERMIT CENTER Conductors shall not be installed in conduit until all work of any nature that may cause damage is completed. Care shall be taken in pulling conductors that insulation is not damaged. U.L. approved non -petroleum base and insulating type pulling compound shall be used as needed. 2. All cables shall be installed and tested in accordance with manufacturer's requirements and HEV1EWEDFOR OMPLIANCE WITH NPPA 70 o NEC B. Splicing and Terminating 1. All aspects of splicing and terminating shall be in accordance with cable manufacturer's pu ished SEP 0 6 2017 procedures. 2. Make up all splices in outlet boxes with connectors as specifiedherein with separate tails color to be made up to splice. Provide at least six (6) inches of tails packed in box after so!' up. f r nrrect 6 s of.k UILDINGTuDIVISION 3. All wire and cable in panels, terminal cabinets and equipment enclosures shall be bundled and clampe END OF SECTION co O) CO a) CO > r V •L N C 0 0 - LC) ,s, U f3 i_ .,...... . o ,. ( a) O. J E O o N o o CO O CY) a) � r � M C'7 Q .4" d U O N N E � C N. O CD CZ to al 1=1)VCOaII" � acc 0 , c0 4 co O N E N RIM C.) tx 0 oz mmi Z c� www.callisonrtkl.com J J J < Q IW Q - Z U W = J FX F- • 2 D O� O r 0 0 n 0 0 Co 0 o 0 I- W 0 0 ISSUED / REVISED DATE PERMIT SET 08/11/16 ADDENDUM #1 09/6/16 PERMIT SET 08/09/17 COPYRIGHT 02016 CALLISON ELECTRICAL SPECIFICATIONS E301