HomeMy WebLinkAboutPermit EL17-0631 - LIDS - LIGHTING, HVAC AND POWERLIDS
990 SOUTHCENTER MALL
EXPIRED 05/21/18
ELI 7-0631
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
9202470010
990 SOUTHCENTER MALL
Project Name: LIDS
ELECTRICAL PERMIT
Permit Number: EL17-0631
Issue Date: 10/25/2017
Permit Expires On: 4/23/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD, WA,
92013
KEVIN WEARE
4000 DELRIDGE WAY SW, STE 300 ,
SEATTLE, WA, 98106
STATIC ELECTRIC INC
34009 48TH AVE E , EATONVILLE,
WA, 98328
STATI E 1951C8
Phone: (206) 795-2629
Phone: (253) 468-3296
Expiration Date: 2/25/2019
DESCRIPTION OF WORK:
NEW LIGHTING AND POWER FOR TENANT SPACE, NEW HVAC, REUSE EXISTING ELECTRICAL DISTRIBUTION
Valuation of single family: $0.00
Valuation of mf/comm: $20,000.00
Type of Work: REMODEL
Fees Collected: $609.46
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2015
Permit Center Authorized Signature: raoti f l/
Date:
'op
r� n
1 hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: (C)— ZS — Zol
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS***
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Electrical Permit No. W''I3(P9)1
Project No.
Date Application Accepted:
Date Application Expires:
(For office us only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
1010
King Co Assessor's Tax No.:
Site Address: pofSouthcenter Mall Suite Number: 446 Floor:
Tenant Name: Lids #5102
PROPERTY OWNER
Name: ctiF "T ffE1✓D
Address: q 705 Qia) DiRGJARo eivg.S ' I
City: .6Ko g." ,e State: 1 Zip: (0077
CONTACT PERSON — person receiving all project
communication
Name: VI/1 WP/2 6:4) AS5c7L,
Address: 4000 _o-le/toUrE wy sw S'30c
City: SEA State:14)A Zip: q /4
0
Phone -26y/
�795Zz,Fax.
Email: kiON c S ecoLuMgi4-SeNriwe4.
New Tenant: ❑ Yes J ..No
ELECTRICAL CONTRACTOR INFORMATION
Company Name: TBD
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.;
Coit
Valuation of Project (contractor's bid price): $ 20,000
Scope of Work (please provide detailed information): New lighting and power for tenant space, new HVAC, reuse
existing electrical distribution.
Will service be altered? ❑ Yes m No Adding more than 50 amps? IJ Yes ❑ No
Type of Use: Retail/Mercantile
Tyne of work:
❑ New 0 Addition ❑ Service Change ® Remodel m Tenant Improvement
❑ Low Voltage 0 Generator 0 Fire Alarm m Telecommunication ❑ Temporary Service
Property Served by:
❑ Puget Sound Energy 0 Seattle City Light
H:Wpplications\Porms-Applications On Line\2014 Applications\Electrical Permit Application Revised l-1-14.docx
Revised: January 2014
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
O Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
O Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
O Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
O Meter/mast repair $68.25
O Low voltage systems $59.85
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $65.00
❑ Temporary service (generator) $80.90
❑ Manufactured/mobile home service $86.25
(excluding garage or outbuilding)
O Carnivals $80.60
Number of concessions $10.80 ea
Each ride and generator truck $10.80 ea
***EFFECTIVE JANUARY 1, 2014 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE***
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELEC RICAL CONTRACTOR:
Signature: ' / , . ' Date: g//5/1/
/
Print Name: J,Via WE4lee Day Telephone:
Mailing Address: 4000 ._>' G.farDLT4_ Wpy S J S - VS b S6.4.. 141,4. qgj IO(
City State Zip
H:\Applications\Forms-Applications On Line \2014 Applications\Electrical Permit Application Revised 1-I-14.docx
Revised: January 2014
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS (
PermitTRAK
ACCOUNT
I QUANTITY I
PAID
$495.03
EL17-0631 Address: 990 SOUTHCENTER MALL
Apn: 9202470010
$495.03
Credit Card Fee
$14.42
Credit Card Fee
R000.369.908.00.00
I
0.00
$14.42
ELECTRICAL
$457.72
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$457.72
TECHNOLOGY FEE
$22.89
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R12652
R000.322.900.04.00
0.00
$22.89
$495.03
Date Paid: Wednesday, October 25, 2017
Paid By: SHANE JOHNSON
Pay Method: CREDIT CARD 071818
Printed: Wednesday, October 25, 2017 3:18 PM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$1,487.62
D17-0222 Address: 990 SOUTHCENTER MALL
Apn: 9202470010
$1,283.96
DEVELOPMENT
$1,283.96
PLAN CHECK FEE
R000.345.830.00.00
0.00
$1,283.96
EL17-0631 Address: 990 SOUTHCENTER MALL
Apn: 9202470010
$114.43 ,;
ELECTRICAL
$114.43
PLAN CHECK FEE
R000.345.832.00.00
0.00
I $114.43
M17-0111 Address: Apn:
$89.23
MECHANICAL
$89.23
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R12137
R000.322.102.00.00
0.00
$89.23
$1,487.62
Date Paid: Tuesday, August 15, 2017
Paid By: KEVIN WEARE
Pay Method: CHECK 1891
Printed: Tuesday, August 15, 2017 1:17 PM 1 of 1
SYSTEMS
INS
PEC IDN NO.
INSPECTION RECORD
Retain a copy with permit
PRMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-36
Project: (I i
Type of Inspection:
•yq;L/
Address:0 AVV
Date Called:
- ric-P wtJ 'SEP t [ -5 put Pi 1.9'
Special Instructions:
/'A 1 f
Date Wanted:
a. •
Requester:
Phone No:
- .,-iroc.-1(
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
"- tfJL-f iphLe c(r. fO"4
— - C O kta r 0 ' tits tifor cdo k)44
- ric-P wtJ 'SEP t [ -5 put Pi 1.9'
- ellE O sit. -0 LAt 6L, -
t 1)1 %d ,tl--70
- &M'/kiwi p"u r/b ii .�0\ vP� tc `s
?I( - Of
- .,-iroc.-1(
Inspector:
Date: t
REINSPECTION( FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P RMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 36
Permit Inspection Request Line (206) 438-9350
Project:1.-'445
Type of Inspection: ��/
f 1,V ft -
Address: pc
itvif/
Date Called:
— 01-01:› i i tt R-
Special Instructions:
— 6 Pita -44— 634.4) i . 1 ``
Date Wanted:' t�
(/
a.m.
Requester:
, !✓
Phone No:
L- 1 i ki 337.
g e- O PY
0 Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
— 01-01:› i i tt R-
Jt R.iC
— 6 Pita -44— 634.4) i . 1 ``
�'�
r7,4 ;+� ., is_o c,.
• 1C& .4.5di
, !✓
g e- O PY
`15A,Lbo%
1.:11,) • c
f_-'
Inspector:
Date:
4124 I 7
REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
L
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36
Permit Inspection Request Line (206) 438-9350
6,17-06,51
Project: 0Type
(�
of Inspection: !A1
4/10,40-1-
Address:
��{
Date Called:
Special Inst uctions:
e��ww
.i a v 4' tt P eD ii pthm-s,
Date Wanted: m
rr3
Requester:
Phone No: 2,53 3a6
Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
O'
.-- e6MAiii CQ V i
.4 "
(
.i a v 4' tt P eD ii pthm-s,
Inspector: 6j
/r1 de(
Date:
REINSPECTIQN FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
l
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. P; RMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36
Permit Inspection Request Line (206) 438-9350
j
Project: (O
Type of Inspection:��C114-
r f
Address: / 6o
1
Date Called:
Special Instructions:
Date Wanted:
am
. p.m.
Requester:
Phone No:
ElApproved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
0 �5'ro(t^� ' e
V
SA-c4C. 7ioo 1 tAPI•
Inspector: cirfgf,
ji
jetk.
Date:
/0/3 . (7
REINSPECT! N FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Project Summary •
PROJ-SUM
2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1
General Info
This PROD -SUM
form shall be
provided as a cover
sheet for all
compliance form
submittals. Project
Title matches project
plans title block.
Project Title: Lids
`y y
Date 8/11/2017
Project Street Address: 2800 Southcenter Mall, Space #446
For Building Department Use
Project City, County, Zip: Tukwila, King,98188
Project Owner or Rep:
r j 3
Jurisdiction:
Project Description
Select all that apply to the
scope of project.
Select Addition + Existing or
Alteration + Existing if the
existing building will be
combined with the addition
or alteration to demonstrate
compliance per Section
C502.1 or C503.1.
Existing
Building
New Construction
❑ New Building
Building
and Additiops
Retrofit
of Occupancy
Scope - Select all that
Hot Water Systems
❑ Building Addition
❑ Alteration + Existing
❑ Historic Building
apply
❑ Building Envelope
❑ Addition + Existing
❑ Change in Space Conditioning
✓ Alteration
❑ Change
Elements
❑ All
❑ Service
-I Mechanical Systems
•' Lighting Systems ./ Electrical Systems
OCCu ariC T e
P Y YP
0 All Commercial 0 Group R - R2, R3, & R4 Q
over 3 stories and all R1
Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R
occupancies.
Mixed Occupancy - Building is three stories or less above grade and it has both Commerical and Group
R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of
the building. The residential spaces shall comply with the WSEC Residential Provisions.
Space Conditioning
Categories
Select
all that apply
to the scope of project
❑ Semi-heated2 ❑ Refrigerated Warehouse,
Walk-in Cooler/Freezer,
Space Category3 Refrigerated Display Case'
Fully Conditioned
❑ Low Energy
Eligible Low Energy Spaces
❑ Unconditioned ❑ Low energy heating/cooling capacity
❑ Wireless service ❑ Greenhouse° ❑ Equipment building
equipment shelter
Floor Area and
Stories
Floors Above
Grade
Building Gross Conditioned Floor Area
Project Gross Conditioned Floor Area
General Compliance
Path
include
QQ Prescriptive
Prescriptive - Projects complying prescriptively
and prescriptve requirements of this code.
with a Prescriptive submittal: All
Total Building Performance - Projects
summary of results from.a.whole building
vith-,.:.,,. '.. , glom
Ow n.11 • • ;�i&W TPE
EJP9�/r/'CP, ipm (eKcept
V ------
0 Total Building Performance
shall demonstrate compliance with all applicable mandatory
Refer to C401.2, Item 1 for more information. Compliance forms to
applicable ENV, LTG, MECH and C406.
complying via total building performance (TBP) shall include a
energy model per Section C407 and shall demonstrate compliance
in this Code. Refer to Section C401.2, Item 2 for more information.
submital: PROJ-SUM, C406 -SUM & C406 -DETAIL, ENV -CHK, LTG-
MECH-ECONO).
Eb• ift--44-sr-i
/U - NtL
AUG 2 3 2017
City of -Tukwila
BUILCING.
P101211
1. Y LLJ
CITY OF TUKWILA
AUG 1 5 2017
PERMIT CENTER
M1'O(o?I
Lighting Summary ;
LGT-SUM
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3
Project Info
Compliance
forms do not
require a
password to
use.
Instructional and
calculating cells
are write -
protected.
Project Title: Lids #5102
Date 8/11/2017
Applicant Information. Provide contact information for individual who can
respond to inquiries about compliance form information provided.
For Building Department Use
Company Name: MPW Engineering, LLC
Company Address: 110 W. 7th Street, Suite 600. Tulsa, OK 74119
Applicant Name: John E. Vest, III
Applicant Phone: (918) 582-4088
Applicant Email:
Project Description
❑ New Building ❑ Addition
Include PROJ-SUM form (included in envelope
J Alteration
4 Plans Induded
forms workbook) with lighting complliance forms.
Building Additions
Refer to Section C502.2.6 for additional
requirements.
Compliance Method
Interior lighting
Exterior lighting
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
❑
❑
Lighting systems in addition are combined with existing
building lighting systems to demonstrate compliance
❑
❑
Addition is combined with existing:
For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting
Wattage table in LTG -INT -BLD or LTG -INT -SPACE form.
For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed
Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form.
Interior and Exterior
Lighting Alterations
Select all Lighting Power and Lighting
Control elements that apply to the scope
of the retrofit project. If project includes a
combination of spaces where less than
50% of the existing fixtures are replaced
in some spaces, and 50% or more of the
fixtures are replaced in others, then
provide separate lighting power
compliance forms for the two retrofit
conditions. Spaces undergoing the same
type of retrofit may be combined into one
lighting power compliance form.
Refer to Section C503.6 for additional
requirements.
All alteration lighting controls shall be
commissioned per C408.3.
❑ No changes are being made to
the interior or exterior lighting
systems and existing space
uses and configuration are not
changed.
Lighting Power
Interior lighting
Parking garage
Exterior lighting
50% or more of existing are replaced
❑
❑
J
Less than 50% of existing are replaced
❑
❑
Lamp and/or ballast replacement only —
existing total wattage not increased
❑
❑
❑
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total
LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed
Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form.
Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the
total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting
Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form.
50% threshold applies to number of luminaires for interior spaces and parking garages, and total
installed wattage for exterior luminaires.
Lighting Controls
Interior lighting
g
Parking garage
Exterior lighting
New wiring installed to serve added
fixtures and/or fixtures relocated to new
circuit(s)
❑
❑
4
New or moved lighting panel
❑
❑
I
Interior space is reconfigured -
luminaires unchanged or relocated only
❑
New wiring or circuit- For interior lighting, provide required manual controls per C405.2.3, occupancy
sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting
controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic
time switch controls per C405.2.2.
Reconfigured interior space - Provide all required lighting controls that apply to a new interior space.
Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces.
Change of Space Use
❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in
LTG -INT -BLD or LTG -INT -SPACE form.
Lighting Summary, :int.
2015 Washington State Energy Code Compliance Forms for
LGT-SUM
_ ..._.__... ,,_ ,, ,,, rcevisea August 2016
Project Title: Lids #5102 Date 8/11/2017
Interior Lighting System
Description
LED lighting controlled by manual controls and time clock. Stockroom lighting on occupancy
sensor.
Interior Lighting Power
Allowance Method
❑ Building Area Method a Space -by -space Method
Select method used in project.
Interior Lighting Controls
J All C405.2.1 - C405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level
Lighting Control (LLLC)
❑ Additional Efficiency Package Option
C406.4 Enhanced digital lighting controls
To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the
required controls per C406.4.
Dwelling Unit Interior
Lighting
Permanently installed interior lighting fixtures in dwelling units comply with: Q
0 C405.2 thru C405.5 Commercial Lighting Controls and LPA
Q C406.3 High Efficacy Lighting
0
Exterior Lighting System
Description
Interior Lighting - SO!ce-By-Space Method •
LTG -INT -SPACE
2015 Washington State Energy Code Compliance Forms for Commercial Buildings includi
..-- --- _...,
Project Title: Lids #5102
ncvwcu t%Uyu0L GU ID
Date 8/11/2017
Calculation
Area NOTE 9
O O Addition - O Addition
stand alone + existing
Q Spaces where < 50% of O Spaces where z 50% of o
luminaires are replaced luminaires are replaced
For Building Department Use
LPA
Calculation
Type
® Standard O Additional Efficiency Package Option O
C406.3 Reduced Interior Lighting Power
To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA.
Refer to C406.3 for additional requirements.
Maximum Allowed Lighting Wattage NOTE'
7
Location (plan #,
room #)
Space Type
Ceiling
Height NOTE 2
Gross Interior
Area in ft2
Allowed
Watts per ft2
Watts Allowed
(watts/ft2 x area)
Sates
Sales area
C - Solais XR4nc
683
1.270
867
Stockroom
Storage room
1
189
0.500
95
LT -01A -ANP W512
3
11
33
Stockroom
T - Cooper SSF-132
4
17
66
Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8
Total Area
Retail Display
872
LTG -INT -DISPLAY
Allowed Watts
Allowance from
544
1506
Proposed Lighting Wattage ""'t'
Location (plan #,
room #)
Fixture Description NOTE 4, 5, 6
Number of
Fixtures
Watts/
Fixture NOTE
Watts
Proposed
Sales
F1B -Solais XSR12
7
34
238
Sales
F1 W - Solais XSR12
4
34
136
Sales
C - Solais XR4nc
2
20
40
Sales
F2B - Solais XR4nc
1
2 0
2 0
Sales
LT -01A -ANP W512
3
11
33
Stockroom
T - Cooper SSF-132
4
17
66
Proposed Retail Display Lighting from LTG -INT -DISPLAY
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts
544
1077
Interior Lighting Power Allowance COMPLIES
Note 1- Lrst all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu.
Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f.
Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing
in fixture description.
Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage
lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50
watts/lineal foot, or enter the wattage limit of permanent current limiting device.
Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage.
Note 9 - Calculation Area Details:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building
lighting systems to demonstrate compliance. Refer to C502.1.
b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a
building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types
and gross interior areas.
c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided
Interior Display Lig*ing - Space -by -Space orf LTG -INT -DISPLAY
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3
Project Title: Lids #5102
Date 8/11/2017
General Note - In Sales areas, an increase in lighting power allowance is permitted for lighting installed
specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible
merchanise display lighting may be included in the Gross Interior Area under each Retail category. This
lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display
Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied
to general area lighting.
Maximum Allowed Retail Display Lighting Wattage
For Building Department Use
Location (plan #,
room #)
Retail Sales Area Type NOTE 1
yp
Gross Interior
Area in ft2NOTE
Allowed Watts
2
per ft2
Watts Allowed
(watts/ft2 x area)
Sales
Retail 3: Furniture, clothing, cosmetics, artwork
293
1.40
410
F1W - Solais XSR12
4
34
136
Total Retail With Display Area
Maximum
293
Total Watts
Base Allowance
Allowance NOTE 3
410
Retail Display Lighting
Retail Display
500
910
Proposed Retail Display Lighting Wattage "OTE 4
Retail Area
Location (plan #,
room #)
Fixture Description NOTE s
Number of
Fixtures
Watts per
Fixture NOTE 6
Watts
Proposed
Retail 3
Sales
F1 B -Solais XSR12
12
34
408
Retail 3
Sales
F1W - Solais XSR12
4
34
136
Total Retail Proposed Display Watts NOTE 7
544
RETAIL DISPLAY WATTAGE ALLOWANCE - AS PROPOSED
Proposed Retail Display Lighting
Totals from LTG -INT -DISPLAY
Retail Display Power Allowance NOTE 8
544
Retail 1
Retail 2
Retail 3
Retail 4
544
Note 1 - Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.2.2.1 may be entered in this table.
Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11.
Note 3 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11.
Note 4 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in
this table.
Note 5 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of
lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture,
lamp, and ballast information.
Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.
For luminaries with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For
low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached
luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device.
Note 7 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG -INT -SPACE.
Note 8 - Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed
Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in
LTG -INT -SPACE.
Note 9 - Enter a unique title for each lobby area in project that has art/exhibit display lighting.
Note 10 - Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c = 0.5 W/ft2.
Note 11 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table.
Note 12 - Only separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of
general area lighting, may be entered in this table.
Note 13 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG -INT -SPACE.
Interior Display Lig"ing - Space -by -Space */ LTG -INT -DISPLAY
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1
Revised July 2016
Project Title: Lids #5102
Date 8/11/2017
General Note - In Lobby areas, an additional wattage allowance is permiited for lighting installed
specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display
lighting may use this additional allowance. Proposed display lighting for each Lobby area may not
exceed this allowance.
Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage
For Building Department Use
Lobby Area "OTE s
Lobby Description including (plan # & room #)
Gross Interior
Area in ft2
Maximum Display
Watts Allowed
Per Area NOTE 10
Proposed Display
Lighting Total
Per Area NOTE 11
Total Lobby with Display Area
Total Lobby Art/Exhibit Display Allowance NOTE 13
Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE 12
Lobby Area
Location (plan #,
room #)
Fixture Description NOTE 5
Number of
Fixtures
Watts per
Fixture NOTE 6
Watts
Proposed
Total Lobby Art/Exhibit Proposed Display Watts
fighting, Motor, and \ ectrical Permit Checklist, IN,. 1 LTG -CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016
Project Title: Lids#5102
Date 8/11/2017
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Washington State Energy Code, Commercial Provisions.
Applicability
(yes,no,na)
Code Section
Component
Compliance information required in permit documents
Location in
Documents
Building Department
Notes
LIGHTING CONTROLS
Yes
C405.2
Lighting controls,
general
For all lighting fixtures, indicate lighting control method on plans
for spaces and lighting zone(s) served, or exception taken
E1.0
NA
C405.2
Luminaire level
lighting controls
(LLLC)
Indicate on plans all fixtures provided with LLLC in lieu of
C405.2 lighting controls; provide description of control
capabilities and performance parameters
C405.1NA
Lighting in dwelling
units
For permanently installed lighting fixtures in dwelling units,
indicate lighting control method on plans for spaces and
lighting zone(s) served, or demonstrate compliance with high
efficacy exception
Yes
C405.2.3
C405.2.1.1
C405.2.2.2
C405.2.4
C405.2.5
Manual controls
Indicate on plans the method of manual lighting control (whether
combined with occupancy sensor, automatic light reduction,
daylight responsive or specific application controls), location of
manual control device and area or specifice application it
serves
E1.0
Yes
C405.2.2.1
C405.2.2.2
C405.2.3
Manual interior
lighting controls
Indicate on plans which method of manual 50% lighting load
reduction is provided, or whether lighting load is reduced via
occupancy sensors or daylight responsive controls
E1.0
Yes
C405.2.2
Method of automatic
Indicate on plans the method of automatic shut-off control
during unoccupied periods (occupancy sensor or time switch)
for all lighting zones;
E1.0, E1.1
shut-off control
Indicate locations where automatic shutoff is provided by other
methods (occupancy sensor or digital timer switch) or which
time switch control exception applies
E1.0
Indicate on plans the spaces served by occupancy sensors;
E1.0
Yes
C405.2.1
C405.2.1.1
Occupancy sensor
controls
Indicate whether occupancy sensor controls are configured to
be manual -on, automatic 50% -on, or serve a space eligible for
automatic 100% -on per exception
NA
C405.2.1.2
Occupancy sensor
controls -
warehouses
Indicate aisleways and open areas in warehouse spaces
provided with occupancy sensor controls that reduce lighting
power by 50%
C405.2.6NA
Digital timer switch
Indicate required digital timer switch control function when
control is used
Yes
0405.2.2.1
Automatic time
switch controls
Indicate locations of override switches on plans and the lighting
zone(s) served, include area sq. ft.
E1.0
Indicate primary and secondary sidelight daylight zone areas on
plans, include sq. ft.;
C405.2.4.2
Daylight zones -
Indicate toplight daylight zone areas on plans, include sq. ft.;
NA
C405.2.4.3
Sidelight and toplight
For small vertical fenestration assemblies (rough opening less
( 9 P 9
than 10 percent of primary daylight zone) where daylight
responsive controls are not required, provide fenestration area
to daylight zone calculation(s)
Indicate on plans lighting zone(s) served by daylight responsive
controls;
C405.2.4NA
Daylight responsive
Identify sidelight and toplight daylight zones that are not
provided with daylight sensing controls and the exception(s) that
apply;
controls
Indicate on plans the lighting load reduction method -
continuous dimming, or stepped dimming that provides at least
two even steps between 0%-100% of rated power;
Indicate that daylight sensing controls are configured to
completely shut off all controlled lights in the lighting zone
NA
C405.2.5
Additional controls
Specific application
lighting controls
Identify spaces and lighting fixtures on plans that require
specific application lighting controls per this section
Yesarea
Items
C405.2.5 -
1&2 lighting
Display and accent
Indicate on plans that display and accent lighting, and display
case lighting are controlled independently from both general
lighting and other lighting applications within the same
space;
El.0
Indicate manual and automatic lighting control method
fighting, Motor, and. fectrical Permit Checklist, ..,,' 2
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1
LTG-CHK
Revised August 2016
Project Title: Lids#5102
Date 8/11/2017
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Washington State Energy Code, Commercial Provisions.
Applicability
(yes,no,na)
Code Section
Component
Compliance information required in permit documents
Location in
Documents
Building Department
Notes
NA
C405.2.5 -
Item 3
Hotel/motel guest
rooms
Indicate method of automatic control - vacancy or captive key
control of all installed luminaires and switched receptacles in
guest room
.
NA
C405.2.5 -
Item 4
Supplemental task
lighting
Indicate method and location of automatic shut-off vacancy
control for supplemental task lighting, including under-shelf or
under-cabinet lighting
NA
C405.2.5 -
Item 5
Lighting for non-
visual applications
Indicate on plans eligible non-visual lighting applications,
include sq. ft. area of each lighting control zone;
.
Indicate on plans that non-visual lighting are controlled
independently from both general area lighting and other lighting
applications within the same space;
Indicate method of manual lighting control and applicable
automatic lighting control
NA
Item 6C405.2 5
Lighting equipment
for sale or
demonstration
Indicate on plans that lighting equipment for sale or
demonstration are controlled independently from both general
areaghting and other lighting applications within the same
p ce;
Indicate method of manual lighting control and applicable
automatic lighting control
Yes
C405.2.5 -
Item 7
Means of egress
lighting
Identify on plans egress fixtures that function as both normal
and emergency means of egress illumination;
E1.0
Provide calculation of lighting power density of total egress
lighting;
If total egress lighting power density is greater than 0.02 W/sq.
ft., indicate on plans egress fixtures requiring automatic shut-off
during unoccupied periods;
Indicate method of automatic shut-off control
NA
C405.2.7
Exterior lighting
controls
Indicate on exterior lighting plans and fixture schedules the
automatic lighting control method, control sequence, and
locations served;
For building facade and landscape lighting, indicate automatic
controls shut off lighting as a function of dawn/dusk and fixed
opening/closing time;
For all other exierior lighting, indicate automatic controls shut off
lighting as a function of available daylight; include control
sequence that also reduces lighting power by at least 30%
between 12am-6am, or from 1 hour after closing to 1 hour
before opening, or based upon motion sensor
NAC405.5.1
Exterior building
grounds lighting
controls
For building grounds fixtures greater than 100 watts, indicate on
plans whether fixtures have efficacy greater than 80 lumens or;
are controlled by motion sensor, or are exempt lighting per
C405.5.2
NA
C405.2.5
Area controls -
Master control
switches and circuit
Indicate location(s) of master control switch(es) intended to
control multiple independent switches; circuit breaker may not
be used as a master control switch;
power limit
Verify that no 20 amp circuit controlled by a single switch or
automatic control is loaded beyond 80%
NA
C406.4
Enhanced digital
To comply with additional efficiency package option, indicate on
plans all interior lighting fixtures that are individually addressed
and provided with continuous dimming, or exception taken;
lighting controls
Include calculation of percent total installed interior lighting
power that is configured with required enhanced lighting control
functions (min 90% to comply with additional efficiency package
option)
NA
C405.13
C408.3 functional
If claiming lighting system commissioning exemption provide
supporting calculation;
Lighting system Identify
testing
applicable commissioning documentation requirements
per Section C408 or eligibility for exception;
Provide written procedures for functional testing of all automatic
controls and describe the expected system response
ig ting, ' oto r, and' . e trical Permit C - 1, E..�: 3 LTG -CHK
2015 Washington State Energy
Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016
Project Title: Lids #5102
Date 8/11/2017
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Washington State Energy Code, Commercial Provisions.
Applicability
(yes,no,na)
Code Section
Component
Compliance information required in permit documents
Location in
Documents
Building Department
Notes
INTERIOR LIGHTING POWER & EFFICACY
Include all luminaires in lighting fixture schedule; indicate fixture
types, lamps, ballasts, and manufacturer's rated watts per
fixture;
E1.0
Yes
C405.4.1
C405.4.1
Total connected
Identify spaces eligible for lighting power exemption on plans
and in compliance forms; indicate the exception applied;
N/A
C405.4.2
interior lighting power
Identify lighting equipment eligible for lighting power exemption
in fixture schedule and in compliance forms; indicate the
exception applied;
N/A
Indicate that exempt lighting equipment is in addition to general
area lighting and is controlled independently
N/A
Yes
C405.3
Exit signs
Indicate location of exit signs on plans and rated watts per
fixture in lighting fixture schedule (maximum 5 watts per fixture)
E1.0
NA
C405.1
Lighting in dwelling
units - lamp efficacy
If high efficacy exception is applied to permanently installed
lighting fixtures in dwelling units, indicate in lighting fixture
schedule if lamps in fixtures are high efficacy per R404.1.
Calculate percentage of fixtures with high efficacy lamps in
project (min 75% to comply with exception).
NA
C406.3
Reduced lighting
power density -
dwelling unit lamp
efficacy
For project with dwelling units, to comply with additional
efficiency package option indicate in lighting fixture schedule if
lamps in fixtures have efficacy rating of 60 lumens per watt or
more. Calculate percentage of fixtures with lamps that have this
efficacy rating (min 95% to comply with option).
Lighting Power Calculation - Indicate compliance path taken
NA
C405.4.2.1
Building Area Method
Complete required compliance forms — proposed wattage per
building area does not exceed maximum allowed wattage per
building area. Identify locations of building areas on plans
Yes
C405.4.2.2
Space -By -Space
Method
Complete required compliance forms — total proposed wattage
does not exceed maximum allowed wattage. Identify locations
of space types on plans, including retail display areas, lobby art
& exhibit display areas, and ceiling heights as applicable
E1.0
NA
C406.3
Reduced lighting
power density
To comply with additional efficiency package option,
demonstrate in compliance forms that total connected interior
lighting wattage is 75% less than the total maximum allowed
lighting wattage via Building Area Method or Space -By -Space
Method
EXTERIOR LIGHTING POWER & EFFICACY
Include all luminaires in lighting fixture schedule; indicate fixture
types, lamps, ballasts, and manufacturer's rated watts per
fixture;
NA
C405.5.2
Total connected
exterior lighting
power
Identify exterior applications eligible for lighting power
exemption on plans and in compliance forms; indicate exception
applied;
Indicate that exempt exterior lighting is controlled independently
from non-exempt exterior lighting; include exception claimed for
each fixture or group of fixtures under exception category
NA
Table
C405.5.2(1)
Exterior lighting zone
Indicate building exterior lighting zone as defined by the AHJ
NA
C405.5.1
Exterior building
grounds lighting
For building grounds fixtures rated at greater than 100 watts that
are complying based on efficacy, indicate rated lamp efficacy (in
lumens per watt) in fixture schedule
NA
C405.5.2
Exterior lighting
power calculations
Complete required compliance form — proposed wattage for
exterior lighting plus base site allowed does not exceed
maximum allowed
ig ting, Motor, and . ;ectrical Permit Checklist,y. 4
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1
LTG-CHK
Revised August 2016
Project Title: Lids#5102
Date 8/11/2017
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Washington State Energy Code, Commercial Provisions.
Applicability
(yes,no,na)
Code Section
Component
Compliance information required in permit documents
Location in
Documents
Building Department
Notes
MOTORS & TRANSFORMERS
NAC405.6
Electrical tranformers
Include electrical transformer schedule on electrical plans;
indicate transformer size, efficiency, or exception taken
NA
C405.7
Dwelling unit
electrical energy
consumption
Indicate on electrical plans that each dwelling unit in Group R-2
has a separate electrical energy meter
NA
C405.8
Electric motor
efficiency
Include all motors, including fractional hp motors, in electric
motor schedule on electrical plans; indicate hp, rpm, rated
efficiency, or exception applied
NA
C405.9.1
Elevator cabs
For luminaires in each elevator cab, provide calculated average
efficacy of combined fixtures that indicates efficacy is not less
than 35 lumens per watt;
Indicate rated watts per cfm for elevator cab ventilation fans do
not exceed 0.33 watts per cfm;
Indicate automatic controls that de-energize lighting and
ventilation fans when elevator is stopped and unoocupied for a
period of 15 minutes or more
NA
C405.9.2
Escalators and
moving walks
Indicate escalators comply with ASME A17.1/CSA B44;
automatic controls are configured to reduce operational speed
to the minimum permitted when not in use
NAC405.9.3
Regenerative drive
Indicate all one-way down or reversible escalators are provided
with a variable frequency regenerative drive
NA
C405.10
Controlled
receptacles
Identify all controlled and uncontrolled receptables on electrical
plans in each space in which they are required; include
receptacle configuration such as spacing between controlled
and uncontrolled, duplex devices, etc;
Indicate on plans whether the method of automatic control for
each controlled receptable zone is by occupant sensor or
programmable time-of-day control
no" is selected for any question, provide explanation:
End of Lighting, Motor & Transformer Permit Documents Checklist
4/2/2018
l i
City of TiTkwila
Department of Community Development
KEVIN WEARE
4000 DELRIDGE WAY SW, STE 300
SEATTLE, WA 98106
RE: Permit No. EL 17-0631
LIDS
990 SOUTHCENTER MALL
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 5/21/2018.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 5/21/2018, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
1/1
achelle ° pley
Permit Technician
File No: EL17-0631
6/9
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
()EMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL17-0631 DATE: 08/16/17
PROJECT NAME: LIDS
SITE ADDRESS: 990 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #,
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
km 9011
Building Divisio
Public Works
11';911
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 08/17/17
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
DUE DATE: 09/14/17
❑ Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
60'-5 718" LEASE LINE
ADJACENT TENANT
• .
SALES AREA
ACT -01
LOWER CASE LETTER INDICATES
SWITCH DESIGNATION, REFER TO
SWITCH BANK DETAILS FOR MORE
INFORMATION
STOCK ROOM
OPEN
FIB FIB
16'-6" A.F.F.
MALL CORRIDOR
REC EEBEOD fAi
MALL
CONCOURSE
111,
LT -01A
a
LT -01A
NEW DUAL RELAY MULTI -TECH WALL
SWITCH OCCUPANCY SENSOR WITH
10 MIN. DELAYED -OFF FOR SECOND
RELAY, 120/277V. LEVITON, MODEL
#OSSMD-FTx.
SOFFIT
SALES AREA 1-
10'-6" A.F.F.
100
ACT -01B
100 1 SALES AREA
d --
MILLWORK FIXT. 10'-0" A.F.F.
ADJACENT TENANT
GYP. BD.
12'-101/2AFF
SOFFIT
GYP. BD.I 10'-0" AFF
MAY 211 26 ,
RECIU
55' %r2C ?ardca)
❑ lectrlcar
lambing
L'1 Gas Piping
City of Tukwila
BOLDING DIVISION
FILE COPY
Permit No. fkl1 O(P2I
Plan roviow a.pprovai is subject to errors and omissions.
Approval of consc:rmtion documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By:
Date:
/0 20 /7
City of Tukwila
BUILDING DIVISION
1
E1.0
LIGHTING PLAN
SCALE: 1/4"=1'-0"
LIGHTING FIXTURE SCHEDULE
SYMBOL
MANUFACTURER &
CATALOG NUMBER
VOLTS/
WATTS
LAMP
FINISH
QTY.
DESCRIPTION
SYMBOL
MANUFACTURER&
CATALOG NUMBER
VOLTS/
WATTS
LAMP
FINISH
QTY.
DESCRIPTION
00
F1B
POWERSECURE/SOLAIS
XSR12/Xm20/25m/30v/1450/BK/B K
34W
LED
19
SEMI -RECESSED LED TWO HEAD
ADJUSTABLE ACCENT LIGHT, BLACK
FINISHES, 25 DEG BEAM OPTICS.
X2
COPPER LIGHTING SURE-LITES
LEM W/ BATTERY BACKUP
120
INCL.
WHITE
4
EXIT - EMERGENCY EXIT LIGHT CEILING
MOUNTED, REFER TO ELECTRICAL
PAINTED TO MATCH ADJACENT CEILING
00
F1W
POWERSECURE/SOLAIS
XS R 12/Xm20/25 m/30v/1450/ W H/ W H
34W
LED
8
SEMI -RECESSED LED TWO HEAD
ADJUSTABLE ACCENT LIGHT, WHITE
FINISHES, 25 DEG BEAM OPTICS.
X1
COPPER LIGHTING - SURE-LITES
AP7-R W/ INTEGRAL BATTERY
120
INCL.
WHITE
3
EMERGENCY EXIT LIGHT WALL /
CEILING MOUNTED, REFER TO
ELECTRICAL
0
F2
POWERSECURE/SOLAIS
XR4nc/D/Xm24/40/30K/SV/SV
20W
LED
2
RECESSED, NOMINAL 4" DIA.
LED DOWNLIGHT, SEMI -DIFFUSE
REFLECTOR AND MATCHING
FLANGE. WIDE FLOOD.
T
COOPER LIGHTING -
8' SURFACE MOUNTED STRIP LIGHT
SSF-132-28T8-UNV-QHE2X32-U
120/277
16.5W
LED T8
WHITE
2
SURFACE MOUNTED
LOCATED IN STOCK ROOM.
0
F2B
POWERSECURE/SOLAIS
XR4nc/D/Xm24/40/30K/SV/BK
20W
LED
1
RECESSED, NOMINAL 4" DIA. LED
DOWNLIGHT, SEMI -DIFFUSE
REFLECTOR AND BLACK FLANGE.
WIDE FLOOD.
ANP LIGHTING
W512-N-W-30K-RTC-BLC-GR12
BLACK FINISH/BLACK GRILL
11W
LED
3
DECORATIVE WAREHOUSE
STYLED PENDANT. BLACK FINISHES
WITH WIRE GRILL ACCESSORY IN
BLACK FINISH. BLACK CORD. NOMINAL
12" DIAMETER.
RECESSEDSPEARER
Ci
ATLAS SOUND (B51- 4)- 4" -70V -
WHITE
2
RECESSED CEILING MOUNTED
COPPER LIGHTING SURE-LITES
LEM W/ BATTERY BACKUP
120
INCL.
WHITE
2
EXIT - EMERGENCY EXIT LIGHT WALL
MOUNTED, REFER TO ELECTRICAL
NOTE:
1. ALL FLUORESCENT LAMPS SHALL BE 3500° KELVIN AND A MIN. CRI OF 82.
2. ALL INTERIOR FLUORESCENT LUMINARIES (FIXTURES) THAT UTILIZE DOUBLE ENDED LAMPS AND CONTAIN BALLASTS THAT CAN BE
SERVICED IN PLACE OR BALLASTED LUMINARIES THAT ARE SUPPLIED FROM MULTIWIRE BRANCH CIRCUITS AND CONTAIN BALLASTS
THAT CAN BE SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL TO THE FIXTURE PER NEC
410.73(GH) EFFECTIVE JANUARY 1, 2008
3. TESTING OF EMERGENCY LIGHTING IS REQUIRED. CALL FOR TESTING PRIOR TO FINAL INSPECTION. (TESTING MUST BE BY
DISCONNECTING MAIN)
*ALL LIGHT FIXTURES TO BE FURNISHED BY OWNER THROUGH CITY LIGHTING. FOR QUESTIONS,
CONTACT:MIKE HOHL
CITY LIGHTING PRODUCTS - ST. LOUIS
VICE PRESIDENT NATIONAL ACCOUNTS
PHONE: 314-534-1090
FAX: 314-534-2810
EMAIL: MHOHL@CITYLIGHTING.COM
SWITCH BANK DETAIL
STOCKROOM
SALES AREA
SALES AREA
SALES AREA
SALES AREA
A-11
A-5
a
A-5
b
A-5
c
A-3
d
LINEAR
TWO -HEAD
LIGHTS
TWO -HEAD
LIGHTS
CASHWRAP
LIGHTS
STOREFRONT
LIGHTS
OVERRIDE
SWITCH
FIXTURES
REVISIONS
No changes h^'1 marle tO the scope
of work with; p -,3r approval of
TI11G,:,ila Et; 'i rf31 division.
NOTE: fl5l iioni will tLw["e o
plan submittal
and my b .Ude ad;.f'-ona I p:an review fees
ELECTRICAL PLAN NOTES
1❑ EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AN CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL
LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL -VOLTAGE WITH BATTERY BACKUP.
FOR LIGHTS WITH EMERGENCY BATTERY BACKUP, NORMAL DUTY BALLAST SHALL BE SWITCHED. EMERGENCY BALLAST TO
ACTIVATE UPON POWER FAILURE ONLY, AND SHALL BE CONNECTED AHEAD OF ANY TIME CLOCKS OR LOCAL SWITCHING
SCHEMES.
n WIRE THROUGH TIME CLOCK.
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
AUG 23 2017
Agi
City of .Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
AUG 1 5 2017
PERMIT CENTER
4 6 1 FROM ROAD
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 F A X
WWW.SARGARCH.COM
ARCHITECTURAL SEAL:
CONTRACTOR'S NOTES:
WRITTEN DIMENSIONS HOLD PRECEDENCE
OVER SCALED DIMENSIONS. DO NOT SCALE
THE DRAWINGS. THE CONTRACTORS MUST
VISIT JOB SITE TO VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS BEFORE
SUBMITTING BIDS. REPORT ANY
DISCREPANCIES OF ANY CONDITIONS WHICH
MAY INTERFERE WITH THE PROPER
EXECUTION OF THE CONTRACT TO THE
TENANTS REPRESENTATIVE. REPORT
DISCREPANCIES DURING BIDDING PROCESS
AND BEFORE START OF CONSTRUCTION.
CHANGE ORDERS WILL NOT BE APPROVED
FOR ISSUES ARISING FROM THE FIELD
CONDITIONS OR CONFLICTS BETWEEN THE
PLANS AND THE EXISTING CONDEIIONS.
DATE
ISSUE
8/11/17 PERMIT, BID, L.L. REVIEW
I
20 u
PROJECT NAME:
Lids
LIDS GENESCO INC.
7555 WOODLAND DRIVE
INDIANAPOLIS, IN 46778
LOCATION:
SOUTHCENTER MALL
SPACE # 446
2800 SOUTHCENTER MALL
TUKWILA, WA 98188
LIDS # 5102
PROJECT INFORMATION:
PROJECT NUMBER: 1998-17
DRAWN BY: JSH REVIEWED BY: ABM
TITLE:
UGHTNG PLAN
SHEET NUMBER:
ElM
512
4 6 1 FROM ROAD
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 F A X
WWW.SARGARCH.COM
ARCHITECTURAL SEAL:
Mk( 2
CONTRACTOR'S NOTES:
WRITTEN DIMENSIONS HOLD PRECEDENCE
OVER SCALED DIMENSIONS. DO NOT SCALE
THE DRAWINGS. THE CONTRACTORS MUST
VISIT JOB SITE TO VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS BEFORE
SUBMITTING BIDS. REPORT ANY
DISCREPANCIES OF ANY CONDITIONS WHICH
MAY INTERFERE WITH THE PROPER
EXECUTION OF THE CONTRACT TO THE
TENANTS REPRESENTATIVE. REPORT
DISCREPANCIES DURING BIDDING PROCESS
AND BEFORE START OF CONSTRUCTION.
CHANGE ORDERS WILL NOT BE APPROVED
FOR ISSUES ARISING FROM THE FIELD
CONDITIONS OR CONFLICTS BETWEEN THE
PLANS AND THE EXISTING CONDITIONS.
DATE
ISSUE
8/11/17
PERMIT, BID, L.L. REVIEW
PROJECT NAME:
Lids
UDS GENESCOINC.
7555 WOODLAND DRIVE
INDIANAPOLIS. IN46278
LOCATION:
SOUTHCENTER MALL
SPACE # 446
2800 SOUTHCENTER MALL
TUKWILA, WA 98188
LIDS #5102
PROJECT INFORMATION:
PROJECT NUMBER: 1998-17
DRAWN BY: ..ISH REVIEWED BY: ABM
TITLE:
R ELECTRICAL
ITH
SHOWN FOR REFERENCE
VERIFY EXACT LOCATION
FIELD.
30 AMP
DISC. SW.
ONLY. /
IN\i
A-20,22,24
A-30
WP
- GFI
/ ' CU -1 (ON ROOF)
Eli
.
i1
11
60'-57/8" LEASE LINE
ItL
/
ADJACENT TENANT
I SALES AREA
100
A-15
ACT -01
11'-0" A.F.F.
A-21
A-17
A A-16
_
A-14
_..
-`+18"
A.F.F. +18" A.F.F.
+18" A.F.F. +18" A.F.F.
5
T
.iii.
■: :�•
}-I
TELE
-
,
,.. 1--4
TEL
PHONE
--I
I
12
BOARD
I
EXISTING
101
STOCK ROOM
A-13
A-23
- 0 EQUIPMENT TO
W
OPEN
16'-6" A.F.F.
REMAIN
i
v I I
-
I
13
POWER FOR CUSTOMIZATION SCREEN. I_
1U
60 AMP
I
-1`
DISC. SW.
A-26,28
I
, , , - - VERIFY LOCATION AND REQUIREMENTS FOR
- INSTALLATION.
`
EXISTING ELECTRICAL
JJ
I
` 3
011 ' -g
I
co
MALL J
PANEL "A"
AHU-1
`
�..1
°
o I
CONCOURSEkr
13
\
els
_
I----
r�`��'
\ 7
L
8
A-1
o
A-71
7�
O
I
A-10,
I I
18 12
4
12
13
I
A-12
i .
A-4
A-29 I _
SW
I
IL
+18'
A.F.F.
T
I
3
I
I
°
+18" A.F.F.
.".
.
j ...
,. i •.": �I
. 111
�.
r
3
13
SOFFIT
A-18
100
A-6 A-2
GYP. BD.
12'-101(2 AFF
'°`-19
100
SALES AREA
100
SALES
AREA
ACT -01B
10'-6" A.F.F.
MILLWORK FIXT.
10'-0" A.F.F.
100
SOFFIT
GYP. BD.
10'-0" AFF
ADJACENT TENANT
ti
0. L �,� 1 .wRt
MAY 2...2H
1
ELECTRICAL FLOOR PLAN
E1.1
SCALE: 1/4"=1'-0"
NOT USED
SYMBOLS AND ABBREVIATIONS
ELECTRICAL PLAN NOTES
LEASE LINE
O
SYMBOL
DESCRIPTION
1
EXISTING ELECTRICAL SERVICE. 100 AMP - 120/208 V, 3PH, 4W. REFER TO DETAIL #2 ON
II N
HOMERUN
$
SWITCH
THIS SHEET FOR MORE INFORMATION.
S
SINGLE DEDICATED RECEPTACLE
z
DUCT MOUNTED SMOKE DETECTOR
2
WIRE THROUGH TIME CLOCK.
TORK SSA200R-24
BYPASS SWITCH
DUPLEX RECEPTACLE
SMOKE DETECTOR
3
QUAD RECEPTACLE TO BE MOUNTED IN CASHWRAP. FIELD VERIFY EXACT LOCATION
WITH CASHWRAP MANUFACTURER.
EXISTING TO REMAIN.
Q�
nSW
DUPLEX RECEPTACLE FOR SHOW WINDOW DISPLAY
GFCI
GROUND FAULT INTERRUPTER
4
ROUTE CONDUIT AND WIRE CONCEALED TO WALL. ROUTE CONDUITS BELOW FLOOR.
CORE & PATCH FLOOR AS REQUIRED. ROUTE TO NEAREST WALL AND THEN UP TO
NEW TIME CLOCK
(7) DAY CALENDAR TYPE
it!
QUADRAPLEX RECEPTACLE
IG
ISOLATED GROUND
ACCESSIBLE CEILING SPACE FOR CONTINUATION.
TORK DLC400BP.
24"X30"X 4" FRT PLYWOOD TELEPHONE BOARD MOUNTED 3" BELOW CEILING GRID WITH
(3) #3 CU & (1) #8 GND
4 POLE 10 AMP
QUADRAPLEX RECEPTACLE W/ (1)®
CLOCK RECEPTACLE
5
1" CONDUIT WITH PULL STRING TO LANDLORD TELEPHONE DISTRIBUTION POINT. VERIFY
&(1)#8LG.IN1-114"C�
0
TO LL'S ELECTRICAL
ETR, V.I.F.
ONE (1) NEW LIGHTING
GFCI
ISOLATED GROUND DEDICATED OUTLET
A.F.F.
ABOVE FINISHED FLOOR
ROUTING AND DISTANCE.
DISTRIBUTION
CONTACTOR - 6 POLES
COMMUNICATION STUB UP FOR PHONE/DATA LINE TO CASH REQISTER/CREDIT
-
®
TELEPHONE/DATA OUTLET
6
SWITCHBOARD
1RD/PHONE.
EACH ASCO 917 STANDARD
OWNER TO PROVIDE SERVICE AND EQUIPMENT, ELECTRICAL CONTRACTOR
- AlA 1 NEMA MECHANICALLY
J
JUNCTION BOX
U.N.O.
UNLESS NOTED OTHERWISE
TO INSTALL (1) 2"C WITH PULL STRING FROM CASHWRAP TO TELEPHONE BOARD.
--$ A-3 HELD WITH ACCESSORY 47
EXISTING
C1
-$ A-5
r
EXHAUST FAN -REFER TO SHEET E2.1/M2.1
ADA
AMERICANS WITH DISABILITIES ACT
7
JUNCTION BOX AND DATA OUTLET FOR EMBROIDERY MACHINE. CONNECT AS REQUIRED
- TC2
-I A-7
`��
N.I.C.
NOT IN CONTRACT
-$ A-11
REMOTE PILOT MTD. ON CEILING TO SIGNAL
8
JUNCTION BOX FOR SIGNAGE. VERIFY EXACT LOCATION AND EpE Jlj V E D
®`
ACTIVATION OF DUCT MOUNTED SMOKE
E
INDICATES ELECTRICAL DEVICES ALREADY INSTALLED.
REQUIREMENTS FOR CONNECTION TO NEW LIDS STOREF ' LGN �'E 4� tC ► (LA' ._
DETECTORS.
G.C. IS TO CONFIRM THEIR LOCATION AND HEIGHT
ED'
LOCAL DISCONNECTING MEANS AND FURNISH AS REQUIREVIEWED
•
PUSH BUTTON
AND MOVE IF REQ'D TO THE DIMENSIONS SHOWN.
9
NOT USED.
AlI
�+
�t ANV
E-CLG
INDICATES ELECTRICAL DEVICES ALREADY INSTALLED IN
A 70 -DISCONNECT
SWITCH
THE CEILING. G.C. IS TO CONFIRM THEIR LOCATION AND
HEIGHT AND MOVE IF REQ'D TO THE DIMENSIONS SHOWN.
10
G.C. TO INSTALL NEW LIGHTSTAT THERMOSTAT (MODEL:
NT NI-
FUSED DISCONNECT SWITCH
11
REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.
AUG 2 3 2
NOTE:
12
DUPLEX RE • TACLE FOR WINDOW DISPLAY.
3/4"
1. COMMUNICATION OUTLET WITH CONDUIT STUBBED UP TO ABOVE ACCESSIBLE CEILING, BOTTOM
OF BOX @ 16", UNLESS NOTED OTHER WISE. PROVIDE PULL STRING.
'
t
011
2
ELECTRICAL SCHEMATIC
2. RECEPTACLES MOUNTED BOTTOM OF BOX @ 16" AFF UNLESS NOTED OTHERWISE.
3. SWITCH MOUNTED TOP OF BOX @ 45" A.F.F.
13
JUNC BOX FOR ES D GE V
T•
ELEC I ENT UGh
E1.1
SCALE: NO SCALE
4 6 1 FROM ROAD
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 F A X
WWW.SARGARCH.COM
ARCHITECTURAL SEAL:
Mk( 2
CONTRACTOR'S NOTES:
WRITTEN DIMENSIONS HOLD PRECEDENCE
OVER SCALED DIMENSIONS. DO NOT SCALE
THE DRAWINGS. THE CONTRACTORS MUST
VISIT JOB SITE TO VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS BEFORE
SUBMITTING BIDS. REPORT ANY
DISCREPANCIES OF ANY CONDITIONS WHICH
MAY INTERFERE WITH THE PROPER
EXECUTION OF THE CONTRACT TO THE
TENANTS REPRESENTATIVE. REPORT
DISCREPANCIES DURING BIDDING PROCESS
AND BEFORE START OF CONSTRUCTION.
CHANGE ORDERS WILL NOT BE APPROVED
FOR ISSUES ARISING FROM THE FIELD
CONDITIONS OR CONFLICTS BETWEEN THE
PLANS AND THE EXISTING CONDITIONS.
DATE
ISSUE
8/11/17
PERMIT, BID, L.L. REVIEW
PROJECT NAME:
Lids
UDS GENESCOINC.
7555 WOODLAND DRIVE
INDIANAPOLIS. IN46278
LOCATION:
SOUTHCENTER MALL
SPACE # 446
2800 SOUTHCENTER MALL
TUKWILA, WA 98188
LIDS #5102
PROJECT INFORMATION:
PROJECT NUMBER: 1998-17
DRAWN BY: ..ISH REVIEWED BY: ABM
TITLE:
R ELECTRICAL
ITH
FLOOR PLAN
SHEET
NUMBER:
Eli
ON
ELECTRICAL SPECIFICATIONS
1. GENERAL PROVISIONS:
A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE
ELECTRICAL SYSTEMS OUTLINED.
B. OBTAIN ALL PERMITS, FEES, LICENSES, INSPECTIONS, AND CERTIFICATES OF COMPLIANCE OR APPROVAL AS
REQUIRED BY THE AUTHORITIES.
C. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST APPROVED EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC), AND ALL APPLICABLE LAWS, CODES, AND REGULATIONS OF THE GOVERNMENTAL
BODIES HAVING JURISDICTION OVER THE SITE.
D. ALL TESTING REQUIRED BY AUTHORITIES SHALL BE CONSIDERED PART OF THIS WORK.
E. DURING CONSTRUCTION, ALL FIXTURES, EQUIPMENT, CONDUIT, ETC. SHALL BE COVERED, PLUGGED, OR
CAPPED AS REQUIRED TO KEEP CLEAN AND UNDAMAGED. ALL DAMAGED ITEMS SHALL BE RESTORED TO
ORIGINAL CONDITION OR REPLACED. ALL PROTECTIVE COVERING SHALL BE REMOVED BEFORE FINAL
ACCEPTANCE.
F. PROVIDE ALL NECESSARY CUTTING AND PATCHING OF WALLS, FLOORS, CEILINGS, AND ROOFS AS
NECESSARY. PATCH AROUND ALL OPENINGS SHALL MATCH ADJACENT AREA. COORDINATE ALL ROOFING
WORK WITH OWNER OR RESPONSIBLE PARTY, SO THAT THE EXISTING ROOFING WARRANTY WILL BE
MAINTAINED.
G. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS AGAINST DEFECTS FOR A PERIOD OF ONE
YEAR FROM FINAL ACCEPTANCE.
2. OPERATION AND MAINTENANCE MANUALS:
A. DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE OPERATING INSTRUCTIONS, WIRING
DIAGRAMS, CATALOG CUTS, LUBRICATION AND PREVENTIVE MAINTENANCE INSTRUCTIONS, PARTS LISTS,
ETC. FOR ALL EQUIPMENT FURNISHED UNDER THIS CONTRACT.
B. ALL LITERATURE AND INSTRUCTIONS SHIPPED WITH THE EQUIPMENT SHALL BE SAVED FOR INCLUSION IN
THE OPERATION AND MAINTENANCE MANUALS.
C. ALL LITERATURE LISTED ABOVE AND ALL PAPERS LISTING WARRANTIES, ETC., SHALL BE BOUND IN A 3 -RING
BINDER AND LABELED WITH THE PROJECT NAME, ADDRESS, ARCHITECT, ENGINEER, CONTRACTORS, ETC.
3. MANUFACTURERS:
A. MANUFACTURERS, MODEL NUMBERS, ETC. INDICATED OR SCHEDULED ON THE DRAWINGS SHALL BE
INTERPRETED AS HAVING ESTABLISHED A STANDARD OF QUALITY AND SHALL NOT BE CONSTRUED AS
LIMITING COMPETITION. ARTICLES, FIXTURES, ETC. OF EQUAL QUALITY BY MANUFACTURERS SHALL BE
ACCEPTABLE, SUBJECT TO STRUCTURAL AND ELECTRICAL CONSTRAINTS OF THE PROJECT DESIGN, UNLESS
NOTED OTHERWISE.
4. TESTING AND BALANCING:
A. ALL CIRCUITS SHALL BE TESTED FOR CONTINUITY, SHORTS, AND GROUNDS BEFORE CONNECTING TO THE
PROPER PHASE AS DESIGNED TO BALANCE THE LOADING BETWEEN PHASES.
B. POWER AND LIGHTING PANELS SHALL BE PROPERLY PHASED TO DISTRIBUTE THE LOAD AND SHALL BE
CONNECTED AND ADJUSTED TO OPERATE AS SPECIFIED.
C. ALL MOTORS AND SIMILAR EQUIPMENT SHALL BE CHECKED FOR PROPER PHASE ROTATION AND OPERATION.
5. RACEWAYS:
A. CONDUIT INSIDE THE BUILDING SHALL BE METALLIC TUBING (EMT), BEARING THE UL LABEL, WITH
COMPRESSION TYPE FITTINGS.
B. CONDUIT EXPOSED TO THE WEATHER, INSTALLED UNDERGROUND, IN CONCRETE, OR USED FOR SERVICE
ENTRANCE SHALL BE STANDARD RIGID CONDUIT (GALVANIZED) WITH THREADED FITTINGS.
C. UNDERGROUND CONDUIT MAY BE POLYVINYL CHLORIDE WITH A DEFLECTION TEMPERATURE UNDER LOAD
AT 264 PSI, OF 78 DEGREES C, AND A TENSILE STRENGTH OF 5,200 PSI. JOINTS SHALL BE FLUSH SOLVENT
WELDED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE EQUAL TO
CARLON POWER AND COMMUNICATIONS DUCT TYPE DB (DIRECT BURIAL). CONDUIT AND FITTINGS SHALL BE
PRODUCED BY THE SAME MANUFACTURER.
D. FLEXIBLE METAL CONDUIT SHALL ONLY BE USED FOR CONNECTIONS TO MOTORS, TRANSFORMERS, AND
LIGHT FIXTURES. MAXIMUM LENGTH SHALL BE 6'-0".
6. CONDUCTORS:
A. WIRES SHALL BE CONTINUOUS WITHOUT SPLICES OR TAPS IN CONDUIT RUNS. ALL SPLICES SHALL BE MADE
IN JUNCTION, PULL, OR OUTLET BOXES. ALL WIRE SHALL BE INSTALLED IN CONDUIT, WIREWAYS, OR OTHER
PROTECTIVE COVER SANCTIONED BY CODE.
B. CONDUCTORS FOR LIGHTING AND POWER SHALL BE COPPER, MINIMUM NO. 12 AWG, 600 VOLT.
C. NO. 10 GAUGE AND SMALLER CONDUCTORS SHALL BE TYPE THWN (WET LOCATIONS) OR THHN (DRY
LOCATIONS), SOLID CONDUCTOR, UNLESS OTHERWISE INDICATED.
D. NO. 8 GAUGE AND LARGER CONDUCTORS SHALL BE TYPE THWN (WET LOCATIONS) OR THHN (DRY
LOCATIONS), STRANDED, UNLESS OTHERWISE INDICATED.
E. SERVICE ENTRANCE AND PANEL FEEDER CONDUCTORS, NO.3 GAUGE AND LARGER SHALL BE TYPE XHHW-2
(WET LOCATIONS) OR THHN (DRY LOCATIONS), STRANDED COPPER, UNLESS OTHERWISE INDICATED.
7. MC CABLE:
A. MC CABLE SHALL CONSIST OF INTERLOCK ARMORED CABLE MADE OF THREE OR FOUR TYPE THHN SOLID (#8
AWG AND LARGER MAY BE STRANDED) COPPER CONDUCTORS INSULATED WITH HEAT AND
MOISTURE -RESISTANT POLYVINYL CHLORIDE (PVC), WITH NYLON OR EQUIVALENT UL LISTED JACKET, PER UL
STANDARD 83. THE THREE CONDUCTORS SHALL BE TWISTED TOGETHER WITH THE COPPER GROUNDING
CONDUCTOR, SUITABLE FILLERS, AND WRAPPED IN BINDER TAPE. THE ASSEMBLY SHALL BE ARMORED WITH
SPIRALLY WRAPPED INTERLOCKED ARMOR OR ALUMINUM OR GALVANIZED STEEL. USE ONLY WHERE
PERMITTED BY AHJ AND LANDLORD.
B. CABLES SHALL BE TESTED IN ACCORDANCE WITH UL STANDARD 1564 FOR TYPE MC CABLE AND RATED AT
600 VOLTS, 90 DEG. C FOR DRY LOCATIONS AND 75 DEG. C FOR WET LOCATIONS.
8. WIRING DEVICES:
A. WALL SWITCHES SHALL BE SPECIFICATION GRADE, QUIET TYPE, FLUSH TOGGLE SWITCHES, RATED FOR 20
AMPS, WITH THERMOPLASTIC COVER PLATES.
1) SINGLE POLE: HUBBELL #CS1221-X OR EQUAL.
2) THREE-WAY: HUBBELL #CS1223-X OR EQUAL.
B. RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX, GROUNDING, THREE -WIRE TYPE, RATED FOR 20
AMPS, WITH THERMOPLASTIC COVER PLATES. HUBBELL #CR5352-X OR EQUAL.
C. GROUND FAULT INTERRUPTER RECEPTACLES (GFI) SHALL BE HUBBELL #GF20-XL. DEVICE COVER PLATES
SHALL BE AS HEREINBEFORE SPECIFIED.
D. ISOLATED GROUND RECEPTACLES (IG) SHALL BE HUBBELL #CR5352IG, ORANGE COLOR. DEVICE COVER
PLATES SHALL BE AS HEREINBEFORE SPECIFIED.
E. RECEPTACLES OUTSIDE BUILDING AND WHERE NOTED AS WEATHERPROOF, SHALL BE AS HEREINBEFORE
SPECIFIED EXCEPT SHALL BE INSTALLED IN A WEATHERPROOF ENCLOSURE WHICH SHALL BE INTERMATIC
#WP1010MC OR #WP1010HMC DIE-CAST METAL WEATHERPROOF RECEPTACLE COVER. COVER SHALL BE
WEATHERPROOF -RATED WHILE IN USE.
F. VERIFY COLOR OF DEVICES AND DEVICE COVER PLATES WITH ARCHITECT.
9. BOXES:
A. HOT DIPPED GALVANIZED STEEL BOXES. PROVIDE TYPE TO SUIT CONDITIONS FOR INSTALLATION.
B. ALL BOXES SHALL BE FLUSH MOUNTED UNLESS INDICATED OTHERWISE.
1. PANELBOARDS:
A. PANELBOARDS ARE EXISTING AND SHALL BE REUSED. PROVIDE ADDITIONAL BREAKERS AS REQUIRED TO
CONNECT CIRCUITS AS SHOWN ON THE DRAWINGS. ADDITIONAL BREAKERS SHALL BE THERMAL MAGNETIC,
QUICK -BREAK BOLT -ON CIRCUIT BREAKERS WITH ONE HANDLE FOR SINGLE OR MULTI -POLE RATINGS AND
SHALL BE COMPATIBLE WITH EXISTING PANELS.
B. PROVIDE NEW, TYPED PANELBOARD DIRECTORY REFLECTING NEW, FINAL CIRCUIT CONFIGURATIONS,
LISTING LOADS SERVED AND OTHER PERTINENT DATA.
2. DISCONNECTS:
A. DISCONNECTS SHALL BE EXTERNALLY OPERATED,QUICK-MAKE, QUICK -BREAK, SAFETY, WITH PROVISIONS,
FOR PADLOCKING. FUSED AND NON-FUSED DISCONNECT SWITCHES SHALL BE PROVIDED AS INDICATED..
B. INDOOR SWITCHES SHALL BE NEMA 1 AND OUTDOOR SWITCHES SHALL BE NEMA 3R UNLESS INDICATED
OTHERWISE.
3. FUSES:
A. FUSES PROTECTING CIRCUIT BREAKER PANELS SHALL BE CURRENT LIMITING U.L. CLASS RK -1 FUSES WITH
200,000 AMPERES RMS SYMMETRIC INTERRUPTING CAPACITY. FUSING ELEMENTS SHALL BE SILVER FOR
RATINGS ABOVE 60 AMPERES.
B. ALL OTHER FUSES SHALL BE U.L. CLASS RK -5, DUAL -ELEMENT WITH A MINIMUM TIME DELAY OF 10 SECONDS
AT 500% RATING. FUSES SHALL HAVE CURRENT -LIMITING SHORT-CIRCUIT LINKS AND 200,000 AMPERES RMS
SYMMETRIC INTERRUPTING CAPACITY. FUSING ELEMENTS SHALL BE COPPER.
4. LIGHT FIXTURES:
A. WHERE LIGHT FIXTURES ARE MOUNTED IN A LAY -IN CEILING, PROVIDE A MINIMUM OF 2 SUPPORT WIRES
ATTACHED DIRECTLY BETWEEN EACH LIGHT FIXTURE AND THE BUILDING STRUCTURE. SUPPORT WIRES
SHALL BE A MINIMUM OF 12 GAUGE GALVANIZED STEEL WIRE, SOFT ANNEALED.
B. FIXTURES ARE REQUIRED AT ALL LIGHTING OUTLETS SHOWN ON THE DRAWINGS. APPROVED LIGHTING
FIXTURE WIRE IS REQUIRED IN ALL FIXTURES AND FIXTURE RACEWAYS. WEATHERPROOF WIRING IS
REQUIRED FOR EXTERIOR FIXTURES. ALL PARTS OF FIXTURES AND WIRING SHALL BE IN ACCORDANCE WITH
NEC REQUIREMENTS.
C. ALL LIGHT FIXTURES SHALL CARRY U.L. AND E.T.L. LABELS. ALL FLUORESCENT FIXTURE BALLASTS SHALL BE
HIGH -FREQUENCY ELECTRONIC BALLASTS WITH A TOTAL HARMONIC DISTORTION OF LESS THAN 20%,
REGARDLESS OF THE NUMBER OF LAMPS CONNECTED TO EACH BALLAST AND SHALL HAVE CBM LABEL. ALL
FLUORESCENT FIXTURES INSTALLED SHALL INCORPORATE BALLAST PROTECTION. ALL FLUORESCENT
BALLASTS SHALL HAVE AN AUDIBLE NOISE RATING OF "CLASS A" OR BETTER. ALL FLUORESCENT BALLASTS
SHALL HAVE A POWER FACTOR GREATER THAN 98% WHEN USED WITH PRIMARY LAMP.
D. ALL FLUORESCENT LAMPS SHALL BE 3500 K COLOR TEMPERATURE WITH A MINIMUM COLOR RENDERING
INDEX (CRI) OF 82.
E. ALL INTERIOR FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED LAMPS AND CONTAIN BALLASTS
THAT CAN BE SERVICED IN PLACE OR BALLASTED LUMINAIRES THAT ARE SUPPLIED FROM MULTIWIRE
BRANCH CIRCUITS AND CONTAIN BALLASTS THAT CAN BE SERVICED I PLACE SHALL HAVE A DISCONNECTING
MEANS EITHER INTERNAL OR EXTERNAL TO THE FIXTURE PER NEC 410.73(G).
5. SLEEVES:
A. PROVIDE, SET, AND PROPERLY LOCATE PIPE SLEEVES AS REQUIRED FOR THIS WORK.
B. INTERIOR PARTITIONS: 16 GAUGE GALVANIZED STEEL, PACK BETWEEN CONDUIT AND SLEEVE WITH FIRE
SAFING AND CAULK AT EACH END WITH FIRE-RESISTANT SEALANT.
C. ROOF: PROSET OR EQUAL, MANUFACTURED PVC SCHEDULE 40 PIPE SLEEVE WITH WEATHERPROOF SEAL.
COORDINATE WITH ROOFING CONTRACTOR AND FLASH AS REQUIRED TO MAINTAIN ROOF WARRANTY.
6. GROUNDING:
A. GROUND ALL ELECTRICAL APPARATUS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) 250
AND ANY LOCAL REQUIREMENTS. ENSURE CONTINUOUS BOND WHERE FLEXIBLE CONDUIT IS USED. PROVIDE
BONDING JUMPER INSIDE ALL FLEXIBLE CONDUIT.
B. BOND METAL PIPING SYSTEMS IN COMPLIANCE WITH NEC 250.4(A)(4).
7. REMODELING WORK:
A. DEMOLITION: DISCONNECT, DEMOLISH, AND REMOVE ABANDONED ELECTRICAL MATERIALS AND EQUIPMENT
INDICATED TO BE REMOVED AND NOT INDICATED TO BE SALVAGED OR REMAIN.
B. EQUIPMENT TO BE SALVAGED:
1) DISCONNECT AND REMOVE EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED AND
SALVAGED. DELIVER EQUIPMENT TO THE LOCATION DESIGNATED BY THE OWNER FOR STORAGE.
2) ALL MATERIALS AND EQUIPMENT DESIGNATED TO BE REUSED OR RELOCATED SHALL BE CAREFULLY
REMOVED AND STORED UNTIL NEEDED FOR REMODELING WORK. ALL ITEMS SHALL BE RESTORED TO
"LIKE NEW" CONDITIONS WITH RUST OR CORROSION REMOVED, SURFACE PAINT TOUCHED UP OR
REPAINTED AS REQUIRED TO MATCH NEW CONSTRUCTION, AND THOROUGHLY CLEANED AND
INSPECTED. ANY ITEMS WHICH BECOME DAMAGED BEYOND REPAIR AS A RESULT OF CONSTRUCTION
OR DEMOLITION ACTIVITY SHALL BE REPLACED WITH NEW MATERIAL EQUIVALENT IN EVERY
RESPECT.HERE EXISTING CONDUITS TERMINATE AT AN EXISTING OUTLET IN A WALL, CEILING, OR FLOOR
TO BE REMOVED, DISCONNECT AND REMOVE DEVICE AND WIRE FROM CONDUIT. CONDUIT SHALL BE
CUT BACK AND CAPPED (BELOW THE FLOOR OR ABOVE THE CEILING) SO NOT TO CREATE AN
OBSTRUCTION. PATCH FLOOR TO MATCH EXISTING.
C. DISPOSAL AND CLEANUP: REMOVE FROM THE SITE AND LEGALLY DISPOSE OF DEMOLISHED MATERIALS AND
EQUIPMENT NOT INDICATED TO BE SALVAGED.
D. PROTECT ADJACENT MATERIALS INDICATED TO REMAIN. INSTALL AND MAINTAIN DUST AND NOISE BARRIERS
TO KEEP DIRT, DUST, AND NOISE FROM BEING TRANSMITTED TO ADJACENT AREAS. REMOVE PROTECTION
AND BARRIERS AFTER REMODELING OPERATIONS ARE COMPLETE.
E. PROVIDE ALL ALTERATIONS AND WORK INDICATED AND/OR REQUIRED FOR THE PROPER INSTALLATION AND
OPERATION OF ALL EXISTING ELECTRICAL SYSTEMS, INTEGRATING THE NEW AND EXISTING AREAS. LOCATE,
IDENTIFY, AND PROTECT ELECTRICAL SERVICES PASSING THROUGH REMODELING AREA AND SERVING
OTHER AREAS OUTSIDE THE REMODELING LIMITS. MAINTAIN SERVICES TO AREAS OUTSIDE REMODELING
LIMITS. WHEN SERVICES MUST BE INTERRUPTED, INSTALL TEMPORARY SERVICES FOR AFFECTED AREAS.
1) ABANDONED CONDUIT SHALL HAVE WIRE REMOVED AND SHALL BE CAPPED. ABANDONED OUTLETS IN
WALLS OR PARTITIONS SHALL HAVE DEVICES AND WIRE REMOVED, AND SHALL BE COVERED.
2) WHERE EXISTING CONDUITS TERMINATE AT AN EXISTING OUTLET IN A WALL, CEILING, OR FLOOR TO BE
REMOVED, DISCONNECT AND REMOVE DEVICE AND WIRE FROM CONDUIT. CONDUIT SHALL BE CUT BACK
AND CAPPED (BELOW THE FLOOR OR ABOVE THE CEILING) SO NOT TO CREATE AN OBSTRUCTION.
PATCH FLOOR TO MATCH EXISTING.
3) WHERE EXISTING CIRCUITS EXTEND BEYOND THE OUTLET IN THE EXISTING WALL, CEILING, OR FLOOR
TO BE REMOVED, FURNISH AND INSTALL NEW CONDUIT AND WIRE TO EITHER REROUTE THE CIRCUIT OR
FEED THE REMAINING OUTLET(S) FROM ANOTHER ELECTRICAL SOURCE, BUT IN SUCH A MANNER AS
NOT TO REVISE THE CIRCUIT. ALL REROUTED CONDUIT SHALL BE APPROVED BY THE ARCHITECT.
4) WHERE EXISTING CIRCUITS IN A WALL, CEILING, OR FLOOR TO BE REMOVED ARE ESSENTIAL TO
MAINTAIN OPERATION OF OTHER REMAINING OUTLETS, RELOCATE THE OUTLET TO A NEW CONVENIENT
LOCATION. EXISTING WIRING DEVICES SHALL NOT BE REUSED, UNLESS OTHERWISE INDICATED.
5) WHERE LIGHT FIXTURES ARE INDICATED TO BE DEMOLISHED, REMOVE ALL WIRE AND MODIFY THE
EXISTING CONDUIT (IF APPLICABLE) FOR THE NEW LIGHTING. ALL UNUSED CONDUIT SHALL BE
REMOVED.
6) WHERE A TELEPHONE CIRCUIT EXTENDS BEYOND AN OUTLET IN AN EXISTING WALL, CEILING, OR FLOOR
TO BE REMOVED, PROVIDE NECESSARY EMPTY CONDUIT AND NOTIFY THE ARCHITECT WHO WILL
REQUEST THE OWNER TO ARRANGE WITH THE TELEPHONE COMPANY FOR NEW WIRING TO OUTLETS
THAT REMAIN.
) WHERE EXISTING CONDUIT AND WIRE RUNS ARE LOCATED IN OR ATTACHED TO AN EXISTING WALL,
CEILING, OR FLOOR TO BE REMOVED, THEY SHALL BE REROUTED IN EITHER NEW OR EXISTING
CONSTRUCTION TO MAINTAIN CONTINUITY OF CIRCUITS UNLESS OTHERWISE INDICATED.
8) CONDUIT SHALL BE CONCEALED WITHIN THE EXISTING BUILDING CONSTRUCTION WHEREVER POSSIBLE,
EXCEPT WHERE OTHERWISE INDICATED.
9) EXISTING WIRE SHALL BE DISCONNECTED AND REMOVED WHEREVER EXISTING CIRCUITS ARE
ABANDONED.
A PANELBOARD
(EXISTING)
MOUNTING: SURFACE
LOCATION: STOCK ROOM
208Y/120V, 3PH, 4W
100A M.C.B.
10,000 AIC
GROUND BUS
DESCRIPTION
WIRE
BRKR
PL
A
KVA
B
C
1
PL
BRKR
WIRE
DESCRIPTION
1
3
5
STOREFRONT SIGN (4,6,9)
ENTRY/WINDOW LIGHTS (4,9)
SALES LIGHTS (4,9)
10
12
12
20
20
20
1
1
1
1.20
0.36
1
1
1
20
20
20
12
12
12
SALES FLOOR RECEPT
EMBROIDERY STATION
CASHWRAP RECEPTS
2
4
6
0.18
1.20
0.87
1.08
7
9
11
STOREFRONT RECEPTS (4,9)
CUSTOMIZATION SCREEN
STOCKROOM LIGHTS (4,9)
12
12
12
20
20
20
1
1
1
0.36
0.36
(
1
1
1
20
20
20
12
12
12
CASH REGISTER (1)
CASH REGISTER (1)
CASH REGISTER (1)
8
10
12
0.50
0.36
0.07
0.36
13
15
17
SECURITY SYSTEM
STOCKROOM RECEPT
STOCKROOM RECEPT
12
12
12
20
20
20
1
1
1
0.36
0.72
1
1
1
20
20
20
12
12
12
SALES FLOOR RECEPTS
SALES FLOOR RECEPTS
SALES FLOOR RECEPT
14
16
18
0.36
0.72
0.36
0.36
19
21
23
SALES DISPLAY
PHONE BOARD
SALES DISPLAYS
12
12
12
20
20
20
1
1
1
0.50
1.68
3
20
12
CU -.1
20
22
24
0.36
1.68
0.50
1.68
25
27
29
SPARE
SPARE
LED SCREENS
12
20
20
20
1
1
1
4.06
2
1
40
20
8
12
AHU-1
CU -1 RECEPT
26
28
30
4.06
0.72
0.18
TOTAL
PER NEC ARTICLE 220
TOTAL LOAD
FEEDER LOAD
9.60
9.41
6.18
KVA
AMPS
AMPS
AMPS
80
79
52
25.18
KVA
KVA
70
25.76
72
K' 212 C
PANELBOARD NOTES ( )
(5)
PROVIDE ISOLATED GROUND WIRE.
INSTALL LOCKING DEVICE (LOCK -OFF FOR MAINTENANCE).
INSTALL LOCKING DEVICE (LOCK -ON FOR CRITICAL LOAD).
WIRE THROUGH LIGHTING CONTACTOR.
PROVIDE GFI BREAKER.
(6) CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. SIZE EQUIPMENT
GROUNDING CONDUCTOR PROPORTIONALLY PER NEC.
COORDINATE WITH UTILITY AND LANDLORD EQUIPMENT FOR AVAILABLE FPRErCEI
CURRENT INTERRUPTING RATINGS.
REFER TO POWER RISER DIAGRAM FOR WIRE SIZES.
WIRE THROUGH TIME CLOCK.
(7)
(8)
(9)
CITY OF T
AUG 1
VED
UKWILA
5 2017
-LOWER-CASE LETTERING ON PANELBOARD SCHEDULES REPRESENTS
ARE EXISTING TO REMAIN.
IANCE WITH
NFPA70 - NEC
-UPPER-CASE LETTERING ON PANELBOARD SCHEDULES REPRESENTS N W OR
MODIFIED LOADS.
AUG 2 3 2017
4 6 1 FROM ROAD
PARAMUS, NJ 07652
9 7 3. 2 5 3. 9 3 9 3 TEL
9 7 3. 2 5 3. 9 3 9 0 F A X
WWW.SARGARCH.COM
ARCHITECTURAL SEAL:
alma
,r
tkA( 2!_ 2 r
CONTRACTOR'S NOTES:
WRITTEN DIMENSIONS HOLD PRECEDENCE
OVER SCALED DIMENSIONS. DO NOT SCALE
THE DRAWINGS. THE CONTRACTORS MUST
VISIT JOB SITE TO VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS BEFORE
SUBMITTING BIDS. REPORT ANY
DISCREPANCIES OF ANY CONDITIONS WHICH
MAY INTERFERE WITH THE PROPER
EXECUTION OF THE CONTRACT TO THE
TENANTS REPRESENTATIVE. REPORT
DISCREPANCIES DURING BIDDING PROCESS
AND BEFORE START OF CONSTRUCTION.
CHANGE ORDERS WILL NOT BE APPROVED
FOR ISSUES ARISING FROM THE FIELD
CONDITIONS OR CONFLICTS BETWEEN THE
PLANS AND THE EXISTING CONDTIIONS.
DATE
ISSUE
8/11/17
PERMIT, BID, L.L. REVIEW
PROJECT NAME:
Lids
LIDS GENESCO INC.
7555 WOODLAND DRIVE
INDIANAPOLIS, IN 46278
LOCATION:
SOUTHCENTER MALL
SPACE # 446
2800 SOUTHCENTER MALL
TUKWILA, WA 98188
LIDS #5102
PROJECT INFORMATION:
PROJECT NUMBER: 1998-17
DRAWN BY: JSH REVIEWED BY: ABM
TITLE:
ELECTRICAL SPECIFICATIONS
AND PANELS
SHEET NUMBER:
1 .2