HomeMy WebLinkAboutPermit EL17-0686 - SEE'S CANDIES - LIGHTING, POWER RECEPTACLES AND DATA OUTLETSSEE'S CANDIES 17100 SOUTHCENTER PKWY SUITE 108 ELI 7-0686 Parcel No: Address: 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 7888920020 Permit Number: EL17-0686 17100 SOUTHCENTER PKWY 108 Issue Date: 1/18/2018 Permit Expires On: 7/17/2018 Project Name: SEES CANDIES Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, CA, 98006 RICHARD ESCALANTE 3434 S LA CIENEGA BLVD , LOS ANGELES, CA, 90016 NORTH PACIFIC ELECTRIC INC 5746 BOSTON HARBOR RD NE , OLYMPIA, WA, 98506-1836 NORTHPE957JA Phone: (310) 993-9635 Phone: (360) 943-6020 Expiration Date: 4/4/2019 DESCRIPTION OF WORK: ADDING NEW LIGTING, POWER RECEPTACLES, AND DATA OUTLETS. RELOCATING EXISTING PANELS TO NEW LOCATION WITHIN SPACE. Valuation of single family: $0.00 Valuation of mf/comm: $75,000.00 Type of Work: Fees Collected: $1,777.83 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: tr 1I1 0.... Date: l -i t '16 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a agree to the conditions attached to this permit. Date: � Signature:/.0c//itil) o20/8 Print Name: '' ` c. --720,e– //—/� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB t CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov a Electrical Permit No. i , / Project No. Date Application Accepted: Date Application Expires: ) (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: Southcenter Square - 17100 Southcenter PKWY Tenant Name: Sees Candies PROPERTY OWNER Name: DAVID KRUEGER - WIG PROPERTIES Address: 4811 134TH PLACE SE City: BELLEVUE State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: RICHARD ESCALANTE Address: 3423 S LA CIENEGA BLVD City: LOS ANGELES State: CA Zip: 90016 Phone: (310) 993-9635 Fax: (310) 842-4436 Email: RESCALANTE@SEES.COM Suite Number: 108 Floor: 1 New Tenant: ❑ Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ /1 000 Scope of Work (please provide detailed information): Adding new lighting, power receptacles, and data outlets. Relocating existing panels to new location within space. Will service be altered? ❑ Yes I1 No Adding more than 50 amps? ❑ Yes m No Type of Use: Retail. Type of work: ❑ New ❑ Addition ❑ Service Change 0 Remodel 0 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applications•Handouts\Permit Applications \PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 • 0 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 9 Manufactured/mobile home service $87.98 (excluding garage or outbuilding) 9 Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: P`i cj ( �jc, G rr- E'!'i) Mailing Address: Day Telephone: Date: 1/ rLt is � L(ia. W:\Pemdt Center\Apphction -Handouts\Permit Applications \PDrs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY PAID $639.47 EL17-0686 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $341.89 Credit Card Fee $9.96 Credit Card Fee R000.369.908.00.00 0.00 $9.96 ELECTRICAL $331.93 PLAN CHECK FEE R000.345.832.00.00 0.00 $331.93 M17-0124 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $231.60 Credit Card Fee $6.75 Credit Card Fee R000.369.908.00.00 0.00 $6.75 MECHANICAL $224.85 PLAN CHECK FEE R000.322.102.00.00 0.00 $224.85 PG17-0110 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $65.98 Credit Card Fee $1.92 Credit Card Fee R000.369.908.00.00 0.00 . $1.92 PLUMBING $64.06 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12285 R000.322.103.00.00 0.00 $64.06 $639.47 Date Paid: Monday, September 11, 2017 Paid By: PAUL WARREN Pay Method: CREDIT CARD 59433D Printed: Monday, September 11, 2017 9:56 AM 1 of 1 CRWYSTEM5 INSPEQTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: jeo. Type of Inspection: Ain.,- A Address/71005 TPlY DateSpecial Insttions: Date Wanted: .„ii CIL Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: \It Z671,ke\ Date: 03/ I I REINSPECTION FEE REQUIRED. Prior to next inspection, fee ust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit FM51 RMIT '0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: ' il!✓4-1 , Address:/ Date Called: Special Inst uctions: e6URequester: �1lI Date Wanted:/� a.: .m Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: ("61,14 ep,i5s ii,DJGiiI- L'o•fr,�Tr Inspector: (661(A)6(— Date: 0,3h CQ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367�f Project: �`A./ _ cndb tC ri TYpeof ef'i 60J44- IN Address: / 7, Date Called:V (,-,, Special Insteuctions: Date Wanted: 4 a. Requester: v / Phone No: 3'0 7o/ /C76 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ( (,-,, ti, / .- 1/a .— ?6. CA- >r v / / z --i rAil L:45:6-5 l A Inspector: Date: dg t7 REINSPECTIOFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit the 7.—O7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-36 -13 Project: �� CType of Inspection: � Address: ' w Date Called: Special fnstru tions: Date Wanted: . m 7C-- ' 4.1n:1.Requester: ,,r.--1 J Als Phone No: 340 0 / /O 7( MApproved per applicable codes. Corrections required prior to approval. COMMENTS: 6 i (V v :74° ' t(: I: Ai o 4 1 5 /+ Inspector: / r bt'AJlC Date: � Z REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. RI COI Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: See's Candies - Tukwila Date 8/25/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. 44E64-J142V 'Y OF T U K SEP 1 1 1 2017 R M iT CENTER nt Use W I L A C Company Name: Dunham Associates, Inc. Company Address: 50 South 6th St. Minneapolis, MN 55402 Applicant Name: Mark Carlson Applicant Phone: 612-465-7675 P E Applicant Email: mark.carlson©dunhameng.com Project Description ❑ New Building ❑ Addition -I Alteration -1 Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions Refer to Section C502.2.6 for additional requirements. FILE Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable ❑ provisions as a stand alone new construction project Lighting systems in addition are combined with existing ❑ building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects. include new + existing interior lighting fixture wattage in Wattage table in LTG-iNT-BLD or LTG -INT -SPACE form, For exterior lighting projects. include new + existing exterior lighting fixture wattage Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. ❑ ❑ Proposed Lighting in Proposed Interior and Exterior Lighting Alterations Select al/ Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate righting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. ❑ No changes are being made to the Interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting ❑ ❑ 50% or more of existing are replaced -' Less than 50% of existing are replaced ❑ ❑ Lamp and/or ballast replacement only — existing total wattage not increased ❑ ❑ 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall LPA per Sections 0405.4.2 and C405.5.2. Include new + existing -to -remain fixtures Lighting Wattage table in LTG -INT -BLD. LTG-iNT-SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures total lighting power prior to alteration. include new + existing -to -remain fixtures in the Wattage table in LTG -INT -BLD. LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces ancfparking garages, installed wattage for exterior luminaires. ❑ ❑ comply with total in Proposed shall not exceed the Proposed Lighting and total Lighting Controls Interior lighting New wiring installed to serve added Parking garage ❑ ❑ controls per C405.2.3. 0405.2.4 and application per C405.2.7. as noted for New Wiring that apply to a not apply to reconfigured Exterior lighting ❑ fixtures and/or fixtures relocated to new -' circuit(s) ❑ New or moved lighting panel .1 Interior space is reconfigured - ■ luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual sensor controls per C405.2.1, daylight responsive controls per controls per C405.2.5. For exterior lighting, provide required controls New or moved panel - Provide all applicable lighting controls time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls Application .specific lighting control provisions per C405.2.5 do occupancy specific lighting and automatic new interior space. spaces. � [Q�F se -. G IIPLIANCEWITH FPA 70 - NEC ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. SEP 2 9 2017 City of Tukwila BUILDING DIVISION 041 -eco Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 Interior Lighting System Description All new lighting installed Interior Lighting Power Allowance Method ❑ Building Area Method U Space -by -space Method Select method used in project. Interior Lighting Controls ❑ All C405.2.1 - 0405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) ,y Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: Q 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 00406.3 High Efficacy Lighting 0 Exterior Lighting System Description No changes - existing to remain Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 Calculation Area "" a 0 0 Addition - 0 Addition stand alone + existing 0 Spaces where < 50% of O Spaces where >_ 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type 0 Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting Power To comply with C406.3. the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE 1 22 Location (plan #, room #) Space Type Ceiling Height NOTE z Gross Interior Area in ft2 Allowed Watts per f12 Watts Allowed (watts/ft2 x area) Retail Sales Sales area Retail Sales 1373 1.270 1744 Restrooms Restroom: all other 62 0.780 48 Office Office: Enclosed 11 53 0.890 47 Stock Room Storage room 38 1201 0. 500 601 Corridor Corridor: all other 38 300 0.530 159 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAYNOTE 8 Total Area Retail Display 2989 LTG -INT -DISPLAY Allowed Watts Allowance from 700 3299 Proposed Lighting Wattage ""'t' Location (plan #, room #) Fixture Description NOTE a, a, s Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed Retail Sales 2'x2' LED Type B 22 35 770 Retail Sales LED Downlight Type D 15 18 270 Retail Sales Fluor. Wall Washer Type G 3 33 99 Stock Room 2'x4' LED Type A 11 38 418 Corridor 254 LED Type A 3 38 114 Bathroom 1'x2' LED Type A 1 38 38 Office 2'x2' LED Type A2 1 36 36 Proposed Retail Disp ay Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 716 2461 Interior Lighting Power Allowance COMPLIES WITH C406.3 Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross inferior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 General Note - In Sales areas, an increase in lighting power allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible merchanise display lighting may be included in the Gross Interior Area under each Retail category. This lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use Location (plan #, room #) Retail Sales Area Type NOTE 1 Gross Interior Area in ft2 Allowed Watts per ft2 NOTE 2 Watts Allowed (watts/ft2 x area) Retail Sales Retail 1: All unclassified retail display 333 0.60 200 Recessed Downlight Type D 19 18 342 Retail 1 Retail - Sales Fluorescent Strip Type C4R 1 54 54 Total Retail With Display Area Maximum 333 Total Watts Base Allowance Allowance NOTE 3 200 Retail Display Lighting Retail Display 500 700 Proposed Retail Display Lighting Wattage NOTE 4 Retail Area Location (plan #, room #) Fixture Description NOTE s Number of Fixtures Watts per Fixture NOTE s Wafts Proposed Retail 1 Retail - Sales 2' Fluorescent Strip Type C2 16 20 320 Retail 1 Retail - Sales Recessed Downlight Type D 19 18 342 Retail 1 Retail - Sales Fluorescent Strip Type C4R 1 54 54 RETAIL DISPLAY WATTAGE ALLOWANCE - PER LPA Proposed Retail Display Lighting Totals from LTG -INT -DISPLAY Total Retail Proposed Display Watts NOTE 7 Retail Display Power Allowance NOTE 8 716 700 Retail 1 Retail 2 Retail 3 Retail 4 716 Note 1 - Select retail sales areas from drop down menu. Only retail sales areas that comply with C405.4.2.2.1 may be entered in this table. Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11. Note 3 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 4 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 5 - For proposed Fixture Description, list ALL proposed display fighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 7 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG -INT -SPACE. Note 8 - Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG -INT -SPACE. Note 9 - Enter a unique title for each lobby area in project that has art/exhibit display lighting. Note 10 - Lobby art and exhibit display wattage allowance per Table C405.4.2(2), Footnote c = 0.5 W/ft2. Note 11- Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table. Note 12 - Only separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of general area lighting, may be entered in this table. Note 13 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG -INT -SPACE. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 General Note - In Lobby areas, an additional wattage allowance is permiited for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting may use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allowance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NOTES Lobby Description including (plan # & room #) Gross Interior Area in ft2 Maximum Display Watts Allowed Per Area NOTE 10 Proposed Display Lighting Total Per Area NOTE 11 Total Lobby with Display Area Total Lobby Art/Exhibit Display Allowance NOTE 13 Proposed Lobby Art/Exhibit Display Lighting Wattage "TE" Lobby Area Location (plan #, room #) Fixture Description "ores Number of Fixtures Watts per Fixture NOTE a Watts Proposed Total Lobby Art/Exhibit Proposed Display Watts Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For at lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken El NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves El Yes C405.2.2.1 0405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls E1 Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; El Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies E1 Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; E1 Indicate whether occupancy sensor controls are configured to be manual-on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception E7 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used Yes C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. El NA C405.2.4.2 0405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA 04052.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section NAarea C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting NA C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; EXIST. Provide calculation of lighting power density of total egress lighting; EXIST. If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; EXIST. Indicate method of automatic shut-off control El NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 Yes C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; N/A Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% El NA C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Yes=05.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; N/A Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; BY E.C. Provide written procedures for functional testing of all automatic controls and describe the expected system response BY E.C. Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all Rt Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 0405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; El Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; N/A Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; N/A Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently N/A Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) El NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Yes C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option), El Lighting Power Calculation - Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yes C405.4.2.2 Space-By-Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable THESE FORMS Yes C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space-By-Space Method THESE FORMS EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed elk \v./ Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all 81 Revised July 2016 Project Title: See's Candies - Tukwila Date 8/25/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; E2 Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control BY RECEPT. TYPE no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist HERMIT COOED COPY c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0686 DATE: 09/12/17 PROJECT NAME: SEES CANDY SITE ADDRESS: 17100 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 34?› AL »r ? Building Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 09/12/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/10/17 ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORTH PACIFIC ELECTRIC INC© Home Espanol Contnet. Safety & Health Claims & Insurance Washington State Department of 4) Labor & Industries Search L&I A -Z Index lielp Page 1 of 3 ARt My LC:I Workplace Rights Trades & Licensing NORTH PACIFIC ELECTRIC INC Owner or tradesperson Principals KULLMANN, BERNHARD M, PRESIDENT Rodgers Kee & Pearson PS, AGENT DITLEVSON, RICHARD, AGENT (End: 03/22/2011) C Scott Kee, AGENT (End: 04/09/2013) 5746 BOSTON HARBOR RD OLYMPIA, WA 98506 360-943-6020 THURSTON County License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ...................._....................................... Meets current requirements. License specialties GENERAL License no. NORTHPE957JA Effective — expiration 04/01/2005— 04/04/2019 Designated administrator KULLMANN, BERNHARD Active. Meets current requirements. License type License no. Master Electrician KULLMBM974BU Bond OHIO CAS INS CO Bond account no. 3670240 $4,000.00 Received by L&I Effective date 04/01/2005 04/01/2005 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. ECHAP01594 Issue date 04/09/2014 Violation city OLYMPIA Type of violation ELECTRICAL CITATION Satisfied .................. RC WNVAC 19.28.101 RCW Violation amount $1,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602117535&LIC=NORTHPE957JA&SAW= 1/11/2018 NORTH PACIFIC ELECTRIC INC Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296-46B-901. Infraction no. ECHAP01584 Issue date 02/10/2014 Violation city OLYMPIA Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296-46B-901. Satisfied ... .................... RCW/WAC 19.28.101 RCW Violation amount $250.00 �1 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 284,080-02 ................................. Doing business as NORTH PACIFIC ELECTRIC INC Estimated workers reported Quarter 3 of Year 2017 "4 to 6 Workers" L&I account contact T4 / STEPHEN TASSONI (360)902-4819 - Email: TASS235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid .........................................................._.............................. No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602117535&LIC=NORTHPE957JA&SAW= 1/11/2018 NOTE SEE ARCHITECTURAL PAGES FOR SPECIFIC FIXTURE LAYOUT LOCATION AND DIMENSIONS. iI COMPACT FLUORESCENT BEYOND. 1)11111111111111111111 11111 11111 IIiii�IIIII i1ll 1 1 iii III 1 1 I� IIIIIIIIIIIII 1 I I �00 1 1/2" X 1 1/2" CHROME - EGGCRATE DIFFUSER. G.C. TO FIELD CUT FIT IIIIII1IIII HI I I I I I I I I I I I I I I 1" X 3" HARDWOOD TRIM WITH P. LAM. FINISH. PL -1 2'-3" (LIGHT SOFFIT) LIGHT VALANCE SECTION NO SCALE SUSP. T -BAR CEILING SEE ARCHITECTURAL PLANS FOR MILLWORK DRAWINGS 4' FLUORESCENT LIGHT FIXTURE CENTERED OVER SHADOW BOX BELOW. VALANCE SUPPLIED BY SEE'S INSTALLED BY G.C. LED LIGHT PROVIDE 1" FLEXIBLE CONDUIT AT 75 1/2" TO ABOVE CEILING, VERIFY LOCATION WITH SEE'S PROJECT MANAGER UNFINISHED EXTERIOR BACK 3/4" I' ILLUMINATED GRAPHIC BOX SUPPLIED BY SEE'S. G.C. TO INSTALL SEE ARCHITECTURAL PLANS FOR MILLWORK DRAWINGS IWIMM SELF—SERVICE CASE SECTION NO SCALE NOTES FOR THIS DRAWING O PROVIDE OCCUPANCY/VACANCY SENSOR. SEE MATRIX BELOW. O2 EXIT AND NIGHT LIGHTS MUST BE CONNECTED TO BYPASS SWITCH CONTROL. • PROVIDE JUNCTION BOX AND DISCONNECT SWITCH IN A CONCEALED LOCATION AT THE STOREFRONT FOR CONNECTION TO STOREFRONT SIGN SEE ARCHITECTURAL PLANS FOR SIGN LOCATION. MATCH EXISTING CONTROL FOR SIGN. O4 LOCATE TIMECLOCK AND CONTACTORS AS REQUIRED NEAR PANEL 'L'. SEE CONTROL MATRIX ON THIS SHEET. O VERIFY THERE EXISTS EMERGENCY LIGHT AT EXTERIOR. PROVIDE NEW FIXTURE TYPE 'H' AS REQUIRED ONLY IF ANOTHER EMERGENCY LIGHT DOESN'T EXIST. CONNECT TO GENERAL BUILDING LIGHTING CIRCUIT. • PROVIDE CONDUIT STUB AT 31" AND 75-1/2" FOR SELF SERVICE CASE LED LIGHTING. SEE DETAIL 4 ON SHEET El AND DETAIL ON SHEET A6 FOR ADDITIONAL INFORMATION. O7 PROVIDE SWITCHES AS SHOWN. LOCATE OVERRIDE SWITCH NEAR THESE DIMMERS/SWITCHES. SEE CONTROL MATRIX ON THIS SHEET. • THIS FIXTURE TO BE AN EMERGENCY LIGHT ONLY, NOT A NIGHT LIGHT. J—/// COUNTER TOP 24" FLUORESCENT STRIP LIGHT CENTER FIXTURES WITHIN EACH BAY LOWER CASE LIGHT FIXTURE DETAILS NO SCALE GENERAL NOTES A. ALL LIGHT FIXTURES PROVIDED BY SEE'S CANDIES INSTALLED BY CONTRACTOR UNLESS NOTED OTHERWISE. B. ALL HOMERUNS SHALL BE 1/2" CONDUIT WITH 2#12 AWG UNLESS OTHERWISE INDICATED. LIGHTING CONTROL MATRIX TO COMPLY WITH WASHINGTON STATE ENERGY CODE REQUIREMENTS ROOM / AREA SERVED SWITCH FIXTURE TYPE MANUAL SWITCH ON/OFF MANUAL DIMMER OCCUPANCY/ VACANCY SENSOR TIME CLOCK ON/OFF LIGHT REDUCTION 50% SWITCHING DIMMING TYPE DIMMING LEVEL AFTER HOURS OVERRIDE SEE KEYNOTES BELOW SALES (GENERAL LIGHTS) a,b B,D X --- --- X X --- --- X --- SALES (EMER./NIGHT LIGHTS) NO SWITCH B1 X --- --- X --- --- --- X --- SALES (DISPLAY LIGHTS) c G X --- --- X --- --- --- X --- SALES (DISPLAY LIGHTS) d C2 X --- --- X --- --- --- X --- SALES (DISPLAY LIGHTS) e D,C4R X --- --- X --- --- --- X --- STOCK ROOM f,g A X --- --- X X --- --- X --- OFFICE LOCAL A X --- X --- --- --- --- X --- CORRIDOR LOCAL A X --- X --- --- --- --- X --- BATHROOM LOCAL A2 X --- X --- --- --- --- X --- GENERAL NOTES: A . Provide all parts and pieces necessary to make a functional lighting control system with all controls as marked above. RELOTED 0 Al L-9 NL EM SWIT 5b C FIXTURE TYPE KEY CKT 5, VIA SWITCH 'b' L 5 NL < "NIGHT LIGHT" TEM G "EMERGENCY LIGHT" PANEL & CIRCUIT NUMBER LIGHT FIXTURE C2 (VIA SWITCH 'd' L-3- TYPICAL OF FIFTEEN). 1111111111111111111 11111111110111111.11. 5 L -5a B L -5a L -5b L -5a �, L -5b 5a 5b' Al EM 1-1 ..L el impling II 1 L- - Aallmum mum NE air 1II L B I-� 1-=5,31 LME 111 MIN ISIIIII -- •= 1 1 +L 4*L B L -Sb B L -5a B L -5b B L -5a B1 L-5 NL EM mar EM B1 L-5 NL B L -5a 11111 Iliwirtr'17"1" LX5 A L -9g Al L-9 NL EM SEPP R ATE PERMIT REQ IRE } FOR: r echanical IA Electrical lid lambing as Piping City of Tukwila [L. 11 ILDING DIVISION REVISIONS No chances shall be mad.' to the, scope I< without prior app-;- 1 of +.vita Building Divi- -;ons ivi ;ons will require a n - plan submittal may include additional Von review fees. TO SIGN FILE COPY Permit No...a7` 00(4(0 Plan review approval is Approval of construction the violation of any adopted of approved Field Copy and By: Date: LIGHTING PLAN 1/4" = 1'-O" to aware and omi , } not authorize Receipt edged: City of Tukwila BUILDING DIVISION TO SIGN 0 SIGN DUNHAM �I Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CUENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 +46' AFF O 0 0 Ile [If 0 DISPLAY LIGHTS 0 0 SALES LIGHTS 0 STOCK RM LIGHTS 0 0 SALES LIGHTS 0 0 0 STOCK RM LIGHTS DISPLAY LIGHTS 0 0 CASE LIGHTS PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SWITCHING DETAIL NO SCALE EVIEWED _FOR MPLIANCE WITH FPA 70 NEC LI SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 s.. 0 C > comments 0 SEP 292011 City of Tukwila BUILDING DIVISION IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS, PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: MARK CARLSON PHONE: 612-465-7675 checked by: RM THIS SHEET CONTAINS; LIGHTING PLAN RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER El ARCHITECT'S COMMISSION NUMBER 17-725.161 LOW VOLTAGE WIRING FROM PULL BOXES TO SELF SERVE DISPLAY #1 TO SELF SERVE DISPLAY #2 TO SELF SERVE DISPLAY #3 TO SELF SERVE DISPLAY #4 TO SELF SERVE DISPLAY #5 TO SELF SERVE DISPLAY #6 TO SELF SERVE DISPLAY #/ TO SELF SERVE DISPLAY #8 TO SELF SERVE DISPLAY #1 TO SELF SELFESERVE SERVEDISPLAYA DISPLAY #2 #3 TO SELFE SERVSERVE ES#4SPLAY DISPLAY TO#5 TO SELF SERVE DISPLAY #6 TO SELF SERVE DISPLAY #7 TO SE SERVE DISPLAY #8 PULL BOX FOR LED DISPLAY BOXES C DC DC DC DC DC DC DC DC DC DC C EJ PULL BOX DETAIL ik<-1" FLEX TO / POWER SUPPLY i 1 /2" HOLE FOR LOW VOLTAGE WIRING. EACH 4 -PANEL BOX TO HAVE AN INDIVIDUAL HOME RUN TO POWER SUPPLY LIGHT FIXTURE SCHEDULE FIXTURE LETTER TYPE FIXTURE TYPE VOLT WATTS MOUNTING LAMP FIXTURE DESCRIPTION LOCATION DIMMING TYPE MANUFACTURER'S SERIES NUMBERS NOTES A 2x4 L.E.D. 120 38 RECESSED GYP -BD L.E.D. 2X4 RECESSED GRID TYPE TROFFER STOCK ROOM 0-10V METALUX 24GR-LD4-38-A125-UNV L840-CDI-U-DF-24W-U 0 (+) Al 2x4 L.E.D. EMERGENCY 120 38 RECESSED GYP -BD L.E.D. 2X4 RECESSED GRID TYPE TROFFER WITH EMERGENCY PACK 90 MIN BACKUP STOCK ROOM 0-10V 24GR-LD4-38-Al25-UNV-L840-EL10W-CDI-U-DF-24W-U METALUX A2 1' x4' L.E.D. 120 36 RECESSED L.E.D. 1' x4' RECESSED TOILET ROOM 0-10V GR -LD1 -32-A UNV L835-CDI-U B 2' x 2' L.E.D. 120 35 RECESSED L.E.D. 2' x 2' RECESSED GRID TYPE TROFFER SALES 0-10V CREE #7R22 -32L -40K -10V VERIFY FOR GYP BOARD CEILING B1 2' x 2' L.E.D. EMERGENCY 120 35 RECESSED L.E.D. 2' x 2' RECESSED GRID TYPE TROFFER WITH EMERGENCY BACKUP 90 MIN BACKUP SALES 0-10V CREE #ZR22-32L-40K-10V EB14 VERIFY FOR GYP BOARD CEILING C2 2' FLUORESCENT STRIP 120 20 SURFACE (1) F017T8SPX41 2' SINGLE TUBE FLUORESCENT NARROW STRIP DISPLAY LIGHT TOP MOUNT SELF -SERVE DISPLAY UNIT --- METALUX SNF-117-120EB81 SEE NOTE BELOW C4R 4' FLUORESCENT STRIP 120 54 SURFACE (2) F032T8SPX41 4' DOUBLE TUBE FLUORESCENT NARROW STRIP DISPLAY LIGHT, TOP MOUNT, WITH REFLECTOR BACK COUNTER SHADOW BOX --- METALUX SNF-232-120EB81 WITH REFLECTOR (SNF-ASY SS -4) SEE NOTE BELOW D 6" LED DOWNLIGHT 120 18 RECESSED LED DRIVER RECESSED L.E.D. ENTRY / COUNTER --- HALO #H750ICAT-ML5612940-692SC G 2' FLUORESCENT WALL WASH 120 33 SURFACE (2) F017T8SPX41 1' X 2' DOUBLE TUBE FLUORESCENT WALL WASH DISPLAY LIGHT SALES SELF -SERVE METALUX RWW217MI120VEB81U VERIFY FOR GYP BOARD CEILING SEE NOTE BELOW H EMERGENCY EXTERIOR LIGHT 120 20 SURFACE L.E.D. EMERGENCY LIGHT WITH BATTERY BACKUP EXTERIOR REAR --- LUMINAIRE YWPH610-20W HP-4000K-120-CP-BLK ONLY PROVIDE IF NO OTHER EMERGENCY LIGHT EXISTS X EXIT LIGHT 120 5 SURFACE L.E.D. SINGLE FACE EXIT LIGHT WITH BATTERY BACKUP 90 MIN BACKUP SALES /STOCK --- SURELITE CCX5OGW (+) WHITE W/ RED TRACE TO POWER SUPPLY #1 LIGHT MAT, TYP. WHITE \ TO IPOWER SUPPLY \ TYPICAL SELF SERVE WIRING DETAIL TYPICAL FOR (6) SELF SERVE DISPLAY SECTIONS CEILING I- I 0 (+) 0 (-) 0 (+) 0 (-) 0 (+) 0 (-) 0 (+) (-) \ / \ TYPICAL SELF SERVE WIRING DETAIL TYPICAL FOR (6) SELF SERVE DISPLAY SECTIONS CEILING DISPLAY CASE LTG DETAIL NO SCALE ONTINUE FOR SELF SERVE (SPLAY SECTIONS #5 THRU #8 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 9 2011 City of Tukwila BUILDING DIVISION IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS, PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: MARK CARLSON PHONE: 612-465-7675 DUNHAM �I Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 wee dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba-architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 C 0 date '0 I. -.z o- Ca, oa L. C, 2 O n 0 C T comments PREUM REVIEW 08/16/17 0 PERMIT 8/28/17 0 0 0 0 0 drown by: MC checked by: RM THIS SHEET CONTAINS: LIGHTING. FIXTURE SCHEDULE AND ELECTRICAL DETAILS RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER E2 ARCHITECT'S COMMISSION NUMBER 17-725.161 I C D \ / SELF SERVE DISPLAY #4 SELF SERVE DISPLAY #3 SELF SERVE DISPLAY #2 SELF SERVE DISPLAY #1 DISPLAY CASE LTG DETAIL NO SCALE ONTINUE FOR SELF SERVE (SPLAY SECTIONS #5 THRU #8 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 9 2011 City of Tukwila BUILDING DIVISION IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS, PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: MARK CARLSON PHONE: 612-465-7675 DUNHAM �I Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 wee dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba-architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 C 0 date '0 I. -.z o- Ca, oa L. C, 2 O n 0 C T comments PREUM REVIEW 08/16/17 0 PERMIT 8/28/17 0 0 0 0 0 drown by: MC checked by: RM THIS SHEET CONTAINS: LIGHTING. FIXTURE SCHEDULE AND ELECTRICAL DETAILS RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER E2 ARCHITECT'S COMMISSION NUMBER 17-725.161 • L-14 18" PANEL 'L' L-30 POWER PLAN KEYNOTES • <> NEW WATER HEATER: 208V/34), 9 KW. PROVIDE LOCK -OFF DEVICE IN ELEC. PANEL. PROVIDE DISCONNECT SWITCH IF REQUIRED BY LOCAL CODE. O MOUNT RECEPTACLE BELOW COUNTER. SEE DETAIL 4/E2. VERIFY LOCATION WITH MILLWORK DRAWINGS. O PROVIDE CEILING MOUNTED RECEPTACLE ABOVE SHOW WINDOW. • 18"X18" TELEPHONE BOARD MOUNTED ABOVE CEILING. PAINT WHITE. O5 ELECTRICAL PANEL TO BE RELOCATED. SEE SHEET E5 FOR DETAILS. O6 ROUTE CONDUIT AND WIRE FOR OUTLETS THROUGH MILLWORK. OUTLET BOX SHOULD LINE UP VERTICALLY WITH GROMMET IN MILLWORK TOP. COORDINATE WITH MILLWORK CONTRACTOR. O7 PROVIDE STUBS AT 3" A.F.F. FOR POWER AND DATA SUPPLY TO CASEWORK. CONNECT L.E.D. STRIP LIGHTS TO SAME CIRCUIT AS LIGHTS ABOVE. CONTROL WITH SAME LIGHT SWITCH. FIELD VERIFY CONNECTION AND LOCATION. REFER TO DETAIL 2/E3. O8 E.C. TO MOUNT RECEPTACLE BOX AND DATA BOX (IF APPLICABLE) AT BACK CORNER ON SIDE WALL OF MILLWORK AT THIS LOCATION. O9 PROVIDE J -BOX AT 6" ABOVE CEILING FOR CONNECTION TO L.E.D. STRIPS. CONNECT L.E.D. STRIP LIGHTS TO SAME CIRCUIT AS LIGHTS ABOVE. CONTROL WITH SAME LIGHT SWITCH. FIELD VERIFY CONNECTION AND LOCATION. 10 EXISTING MECHANICAL UNIT. EXTEND CONDUIT AND WIRE TO NEW PANEL LOCATION AND RECONNECT TO PANEL 'L' AS REQUIRED. PROVIDE CONNECTION TO DUCT SMOKE DETECTOR AS REQUIRED. RECONNECT GFI WP RECEPTACLE TO PANEL 'L'. 11 PROVIDE QUAD RECEPTACLE ON WALL FOR DATA CABINET. COORDINATE WITH G.C. MOUNTED DATA CABINET FOR RECEPTACLE MOUNTING HEIGHT PRIOR TO INSTALLATION. FAULT CURRENT AT RTU 12 G.C. PROVIDE DAMAC WLR24AKP1WV-3 WALL MOUNTED DATA CABINET. E.C. PROVIDE 1" RIGID CONDUIT, WITH NYLON BUSHING, STUBBED TO ABOVE CEILING AND CONNECTED TO DATA CABINET. 13 DISCONNECT EXISTING TO BE ABANDONED RTU. REMOVE CONDUIT AND WIRE BACK TO SOURCE. 14 PROVIDE CONTROLLED RECEPTACLE: PASS & SEYMOUR #PLT26351W OR EQUAL. 15 TRENCH FLOOR AS REQUIRED. ROUTE CONDUIT AND WIRE TO CASH WRAP FOR POWER AND DATA CONNECTIONS. PATCH AND REPAIR FLOOR AS REQUIRED. 16 RELOCATE JAMBA JUICE ELECTRICAL PANELS. SEE SHEET E5. 17 APPROXIMATE LOCATION OF EXISTING PANEL 'L'. 1s PROVIDE CONNECTION TO RECIRC PUMP (120V/125 -WATTS). COORDINATE WITH MECHANICAL. L-28 GFI 1,821A FAULT CURRENT AT RTU SEE MECH. EQUIPMENT SCHEDULE THIS SHEET (TYP) MECHANICAL EQUIPMENT SCHEDULE EQUIPMENT TAG EQUIPMENT DESCRIPTION HP LOADFEEDER VOLT/ DISCONNECT POWER SOURCE SIZE 3/4"C.-3 #8, #10 GND (MATCH EXISTING) ELEC NOTES 1 TYPE SIZE FUSE LOCATION PANEL L CB EXIST. 35/3 CKT# 31,33,35 EXIST. RTU VERIFY 208/3 EXIST. II Q HUBBELL P7W WALLPLATE 39 e EXIST. RTU VERIFY 208/3 EXIST. L EXIST. 35/3 37,39,41 3/4"C.-3 #8, #10 GND (MATCH EXISTING) 1 AK W MECHANICAL UNIT EQUIPMENT TAG - SEE SCHEDULE HP EXHAUST FAN 80 W 120/1 DISC. 20A NON UNIT L 20/1 7 1/2"C.-2 #12, #12 GND -- ® INV WATER HEATER 9.0 KW 208/3 LOCK -OFF BREAKER 1 1 L 35/3 38,40,42 3/4"C.-3 #8, #10 GND -- ® v NOTE: 1. RECONNECT EXISTING HVAC UNIT TO ELECTRICAL PANEL "L" AS REQUIRED. MATCH EXISTING BREAKER IN ADJACENT SPACE'S PANEL IN WHICH THIS EXISTING HEAT PUMP WAS/IS CONNECTED TO CURRENTLY. GENERAL NOTE A. TO INCREASE SAFETY TO MAINTENANCE AND SERVICE PERSONNEL WORKING ON ELECTRICAL APPLIANCES, EACH MULTI WIRE BRANCH CIRCUIT WITH SHARED NEUTRAL SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS IN ACCORDANCE WITH REQUIREMENTS ARTICLE 210.4 OF 2008 NEC. NOTE ALL HOMERUNS SHALL BE 1/2" CONDUIT WITH 2#12 AWG AND #12 GND UNLESS OTHERWISE NOTED. CASHWRAP 15" 0 IL lT QUAD RECEPTACLE TELEPHONE/DATA CASHWRAP SECTION — SIDE VIEW NO SCALE WALL -\ DUPLEX RECEPTACLE AND TEL OUTLET TO BE LOCATED IN CABINET (TYP. OF 2 LOCATIONS) BACK BAR 31" UNFINISHED BACK FLOOR BAC K BAR SECTION 4- NO SCALE III POWER PLAN 1/4" = 1'-0" REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC SEP 2 9 2017 of Tukwila SYMBOL S C H� l DIVISION CIRCUIT PANEL 24"x24" CABINET - SEE SHEET E3 TRANSFORMER Mil Y MOTOR OR MOTOR CONNECTION DISCONNECT SWITCH 0 JUNCTION BOX ii) HUBBELL P7W WALLPLATE 39 e DUPLEX RECEPTACLE - WALL/CEILING MOUNT QUADRAPLEX RECEPTACLE - WALL MOUNT €1 iill GFI RECEPTACLE, DUPLEX/QUADRAPLEX- WALL MOUNT 4 1 -GANG DATA OUTLET. SEE DETAIL ON SHEET E3. 3 -GANG DATA OUTLET. SEE DETAIL ON SHEET E3. MECHANICAL UNIT EQUIPMENT TAG - SEE SCHEDULE HP EL DUNHAM MI Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lone Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CUENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 C9 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 4.0 dote 0 c 0'. 0 .64 0 E c 0 0 1 0 �v c > comments PREUM REVIEW 08/16/17 0 BIW PERMIT 8/28/17 O O 00 0 drown by: MC checked by: RM THIS SHEET CONTAINS; POWER PLAN RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER E3 ARCHITECT'S COMMISSION NUMBER 17-725.161 NOTES FOR THIS DRAWING ................................... 3 L �i� 18"X18" TELEPHONE BOARD MOUNTED AT 6" ABOVE CEILING. COORDINATE WITH LANDLORD AND PROVIDE ALL CONDUIT AND WIRING AS REQUIRED FOR CONNECTION TO LANDLORD COMMUNICATION SYSTEM. COORDINATE FINAL LOCATION OF PUSHBUTTON & DOOR BELL WITH ARCHITECTURAL PLANS. TO PUSHBUTTONS IN SALES AREA LED POWER SUPPLY ABOVE CEILING 3/4"C. AND WIRING BY E.C. ❑c ❑( ❑E - PHONE DATA DATA PROVIDE PERMANENT TYPED LABEL WITH LINE DESIGNATIONS PHONE/DATA DETAIL NO SCALE MOUNT PUSH BUTTON IN FACE OF MILLWORK. COORDINATE W/ MILLWORK INSTALLER. ROUTER AND MODEM TO BE LOCATED ABOVE P7W BY SEE'S PROJECT MANAGER. SEE DETAIL 2/E3 FOR MORE INFORMATION. MOUNT DOOR BELL ABOVE P7W. SEE DETAIL 3/E3 FOR MORE INFORMATION. 3/4" CONDUIT AND TELEPHONE/DATA WIRES TO TELEPHONE BOARD BY E.C. SEE DETAIL 4/E3. E.C. TO MOUNT DATA BOX AT BACK CORNER ON SIDE WALL OF MILLWORK AT THIS LOCATION. DATA BOXES TO BE NEXT TO RECEPTACLE BOXES — ALIGNED VERTICALLY WITH MILLWORK GROMIT. ALL CABLING TO BE PLENUM RATED. PROVIDE CAT.5E CABLE FROM SCALE LOCATION TO TERMINATE AT PATCH PANEL. PROVIDE (1) CAT5e FROM 66 BLOCK TO PATCH PANEL. MARK: "HUGHES" / INCOMING DSL. SEE DETAIL 2/E3. TELEPHONE LINE NOTES GENERAL NOTE: SEE'S PROJECT MANAGER TO IDENTIFY ALL PHONE LINE NUMBERS. Q LINE 1: (MAIN LINE) FOR PHONE, FAX AND DSL.. ® LINE 2: CREDIT CARD TERMINALS. ( 3 ) LINE 3: CREDIT CARD TERMINALS. GENERAL NOTES A. GENERAL CONTRACTOR SHALL PROVIDE ALL TELEPHONE AND NETWORK CAT 5E CABLE WITHIN THE SPACE. GENERAL CONTRACTOR TO ALSO PROVIDE 25 PAIR FROM BUILDING MAIN POINT OF ENTRY TO TENANT MAIN POINT OF ENTRY & CONNECT TO TENANT'S 66 BLOCK AT EACH END. COORDINATE FULLY WITH SEE'S CANDY PROJECT MANAGER. B. CAT 5E SHALL BE PROPERLY TERMINATED WITH AN RJ45 CONNECTOR, TESTED FOR CONTINUITY AND PROPERLY LABELED AT EACH END FOR EACH LOCATION: ALL CAT 5E CONNECTIONS SHALL BE MADE USING A STANDARD B CONFIGURATION. ALL INSTANCES OF DATA OUTLETS TO BE VOICE AND CAT5 COMBO JACKS PROVIDED & INSTALLED BY CONTRACTOR. C. PROVIDE HUBBELL P7W DEVICE PLATE PIGTAIL 6' OF NETWORK CABLE COIL AS DIRECTED BY SEE'S CANDIES PROJECT MANAGER. ALL DATA TO RUN TO P7W. D. CONTRACTOR SHALL PROVIDE 25 PAIR LINE FROM MAIN POINT OF ENTRY TO PHONE BOARD, HOOK ALL WIRES UP TO TELEPHONE BOARD, AND COMPLETE CROSSOVER TO PHONE COMPANY SIDE. CONTRACTOR SHALL INSTALL 66 BLOCK AT BOTH THE MAIN POINT OF ENTRY AND TENANT'S TELEPHONE BOARD IF NOT PROVIDED BY LL. E. G.C. TO PROVIDE TWO-TONE DOOR BELL SYSTEM FOR DOORS. SALES AREA AND REAR DOOR SHALL HAVE DIFFERENT TONES. F. ROUTER AND MODEM TO BE LOCATED ABOVE P7W BY SEE's PROJECT MANAGER. G. ALL LOW VOLTAGE TO BE INSTALLED BY A QUALIFIED TECHNICIAN PER THE SP PAGES. TELEPHONE BOARD 25 PR. TO MPOE 66 BLOCK VOICE I LINES TO WALL SWITCH • DOOR BELL BACK ROOM (BY OTHERS) ROUTER MODEM PROVIDE 24—PORT HINGED 2 POS 3.5" HIGH X 6" DEEP PATCH PANEL. LEVITON #132-49255—H24 QUICKPORT PATCH PANEL 24—PORT 1 RU EMPTY TABLEAU WITH LEVITON #200-49251—W62 (BLACK) MOUNT. P7W DATA LINES PROVIDE PLENUM RATED CAT.5E CABLE FROM SCALE LOCATION TO TERMINATE AT THIS PATCH PANEL. XESZSISZSZO=11 TO VOICE LOCATIONS LED POWER SUPPLY TO DTA LOCA IONS SALES AREA (REFER TO 4/A6) LOW VOLTAGE FOR LED IN GLASS BULK CASE STUB FOR POWER IN TOE—KICK STUB FOR DATA/VOICE IN TOE—KICK LOW VOLTAGE DETAIL NOT TO SCALE V GVIIE DE 44 //�/1/////t% il 8'1 1i .. i Ell IEl= MN APrAmorArAmmorirAmmorArArArawrimrdrommarrimrAmoromm 11111 0 VO .�. .............. PLAN Eill REVIEWED FOR COMPLIANCE WITH NFPA 70 @ NEC SEP 2 9 2011 City of Tukwila BUILDING DIVISION DUNHAM Ain! Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 c dote 0 c 0 0. .9 0 0 0 L 0 v c > comments PRELIM REVIEW 08/16/17 0 PIERMR 8/28/17 0 0 0 0 0 drawn by: MC checked by: RM THIS SHEET CONTAINS; LOW VOLTAGE PLAN RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER E4 ARCHITECT'S COMMISSION NUMBER 17.725.161 LANDLORD'S SPACE TENANT'S SPACE EXISTING 200 AMP FEEDER EXTEND TO NEW LOCATION OF RELOCATED PANEL. VERIFY A MINIMUM OF 3/0 CU. 200 200 EXISTING 200 AMP FEEDER (APPROX. 300' FROM LL's ELEC ROOM) EXISTING MAIN BREAKER 65000A AND METER TO REMAIN X ' VERIFY REQUIREMENTS WITH LANDLORD AND ELECTRICAL UTILITY FOR MAINTAINING METERS AND SWITCHES. .^. 200 LANDLORD'S ELEC. DISTRIBUTION EXTEND TO NEW LOCATION OF RELOCATED PANEL. VERIFY A MINIMUM OF 3/0 CU. PANEL „L„ 4,009A SEE'S CANDIES 0 RELOCATE EXISTING PANEL. SEE SHEET El FOR LOCATION. CALCULATED AVAILABLE FAULT CURRENT (TYP). NOTE: ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND FIELD VERIFY EXISTING CONDITIONS. NOTIFY ENGINEER OF ANY DISCREPANCIES. COORDINATE WITH LANDLORD. %1 \ ELECTRICAL RISER DIAGRAM NO SCALE CONTRACTOR SHALL VERIFY ALL PANEL SIZES, WIRE SIZES AND MAIN BREAKERS PRIOR TO BID. IF THERE ARE ANY DISCREPANCIES CONTRACTOR SHALL CONTACT OWNER OR ENGINEER PRIOR TO START OF CONSTRUCTION. EXIST. JAMBA JUICE PANEL 1 4,009A EXIST. JAMBA JUICE PANEL 2 4,009A RELOCATE EXISTING ELECTRICAL PANELS FROM 'JAMBA JUICE' SPACE. EXTEND CONDUIT AND WIRE AS REQUIRED. MAINTAIN CONNECTIONS TO EXISTING SWITCHES IN LANDLORD'S DISTRIBUTION PANEL. VERIFY REQUIREMENTS WITH LANDLORD. Panel: L Voltage: 120/208v, 3Ph, 4w No. Amp/p Note Description Ph Code L VA Code C VA Code R VA Code M VA Code E VA Code K VA Code D VA 1 20/1 1,2,3 DISPLAY LIGHTS -A - 374 3 20/1 1,2,3 SELF SERVICE DISPLAY CASE LIGHTS - B - 300 5 20/1 1,2,3 SALES LIGHTS - C - 1034 7 20/1 BATHROOM, CORRIDOR, OFFICE LTS - A - 188 60 9 20/1 1,2,3 STOCK ROOM LIGHTS - B - 418 11 20/1 1,2,3 SIGN - C - 1200 13 20/1 EXIST. DUCT SMOKE DETs - A - 50 15 20/1 1,2,3 SIGN - B - 1200 17 20/1 1,2,3 SIGN - C - 1200 19 20/1 RECIRC PUMP - A - 125 21 20/1 SPARE - B - 23 20/1 SPARE - C - 25 20/1 SPARE - A - 27 20/1 SPARE - B - 29 -C- 31 35 4 EXIST. RTU -1 - A - 3521 33 / " -B- 3521 35 3" - C - 3521 37 35 4 EXIST. RTU -2 - A - 3521 39 /" - B - 3521 41 3" -C- 3521 2 20/1 CASH REGISTER - A - 720 4 20/1 CASH REGISTER - B - 360 6 20/1 SPARE - C - 8 20/1 LED STRIPS - A - 100 10 20/1 COUNTER RECEPTACLES - B - 720 12 20/1 COUNTER RECEPTACLES - C - 200 14 20/1 STOCKROOM RECEPTACLES - A - 1080 16 20/1 STOCKROOM RECEPTACLES - B - 720 18 20/1 SPARE - C - 20 20/1 SHOW WINDOW RECEPTACLES - A - 540 22 20/1 MANAGER'S DESK RECEPTACLES - B - 720 24 20/1 DATA CABINET - C - 360 26 20/1 SPARE - A - 28 20/1 EXIST. RTU RECEPTACLES - B - 360 30 20/1 OFFICE RECEPTS - C - 180 400 32 20/1 SPARE - A - 34 20/1 SPARE - B - 36 20/1 SPARE - C - 38 35 3 WATER HEATER - A - 3000 40 / II - B - 3000 42 3 - C - 3000 Through Feed Lug ' Connection NONE - A - - - B - - - C - Main Breaker - -A - 662 1620 3770 7227 0 0 0 MLO - B - 1918 1800 4080 7042 0 0 0 - - C- 3434 380 3760 7042 0 0 0 Overcurrent Device Notes: Conn KVA phase loads Total - A - - B - - C - 1 - ROUTE CIRCUIT THROUGH CONTACTOR 42.7 13.3 14.8 14.6 2 - ROUTE CIRCUIT THROUGH TIME CLOCK Dmd Conn Bus KVA loads 3 - PROVIDE LOCK -OFF DEVICE 7.5 6.0 Code L'Lighting 4 - EXISTING RTU, RECONNECT TO RELOCATED PANEL . 3.8 3.8 Code C' Convenience Receptacles (180 W) 5 - 11.6 11.6 Code R7 Receptacles (Non Convenience) Panelboard Notes: 23.7 21.3 Code M' Motors Largest Mtr VA = 9600 ' 1 - 0.0 0.0 Code E = Electric Heat 2 - 0.0 0.0 Code K 7 Kitchen Equip Dmd = 100% ' 3 - 0.0 0.0 Code D7 Dwelling Units (Hotel/Motel Rooms) 4 - 47 43 Total KVA 5 - 0 Spare KVA Spare = 0% ' RELOC. : Mounting 47 Adjusted KVA (Demand + Spare KVA) EXISTING : Amps AIC Rating 130 Adjusted Amps (Demand + Spare KVA) 225 : Amp Rating of Bus 135 High Phase Amps (Demand + Spare KVA) 8/25/2017 MLO : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 208 : Phase to Phase Voltage PANEL L 418743 See's Candies ELECTRICAL LOAD SUMMARY LOAD TYPE CONNECT. LOAD (KW) DEMAND FACTOR DEMAND LOAD (KW) LIGHTING 6.0 1.25 7.5 RECEPTACLES 6.4 1.00 6.4 WATER HEATER 9.0 1.00 9.0 H.V.A.C. 21.3 1.00* 23.7 TOTAL 42.7 46.6 SERVICE SIZING LOAD = 46.6 KW 46.6 KW ® 208V/3PH = 130 AMPS DAT - REVIEWED .FOR COMPLIANCE WITH NFPA 70 d NEC SEP 2 q 2017 City of Tukwila BUILDING DIVISION DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 Fax 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E-mail: officeOmba-architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 C H-1 B SEE'S CANDIES 3423 S CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 c date 0 c 0 4.0 a 0 c 0 0 0 0 c > comments PRELIM REVIEW 08/16/17 0 PERMIT 8/28/17 0 0 0 0 0 derby. MC checked by: RM THIS SHEET CONTAINS; ELECTRICAL DETAILS RECEIVED CITY OF TUKWILA SEP 112017 PERMIT CENTER E5 ARCHITECT'S COMMISSION NUMBER 17-725.161