Loading...
HomeMy WebLinkAboutPermit EL17-0694 - TARGET - TENANT IMPROVEMENTTARGET 301 STRANDER BLVD ELI 7-0694 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049005 301 STRANDER BLVD Project Name: TARGET ELECTRICAL PERMIT Permit Number: EL17-0694 Issue Date: 1/3/2018 Permit Expires On: 7/2/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TARGET CORPORATION T 0627 PO BOX 9456 C/O PROPERTY TAX/TPN 0950, MINNEAPOLIS, WA, 55440 ELLE REINHARD Phone: (206) 962-6865 1101 2ND AVE #100 , SEATTLE, WA, 98101 KEN BOBKO ELECTRIC CO INC PO BOX 7009 , TACOMA, WA, 98417 KENBOEC066BA Phone: (253) 756-0944 Expiration Date: DESCRIPTION OF WORK: AGE, CONDITION AND OPERATIONAL ENHANCEMENTS OF THE BASE BUILDING AND GUEST EXPERIENCE. SALES FLOOR AND VARIOUS DEPARTMENTS REMODELED. NO MAJOR ELECTRICAL DISTRIBUTION REVISIONS. Valuation of single family: $0.00 Valuation of mf/comm: $378,452.00 Type of Work: REMODEL Fees Collected: $6,810.23 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: � 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permto the conditions attached to this permit. Signature: Print Na Date: `l 3/26 ! C� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line:(206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwila W A. goy Electrical Permit No. I1'. elf, t Project No. Date Application Accepted: "I I 1 (1 Date Application Expires: 1)\101 ttY (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 262304900505 Site Address: 301 Strander Blvd., Tukwila, WA 98188 Suite Number: N/A Floor: N/A Tenant Name: Target Corporation PROPERTY OWNER Name: Elle Reinhard Address: 1101 Second Ave, Ste. 100 Name: Target Phone: (206) 962-6895 Fax: Email: elle.reinhard@mg2.com Address: 1000 Nicollet Mall City: Minneapolis State: MN Zip: 55403 CONTACT PERSON — person receiving all project communication Name: Elle Reinhard Address: 1101 Second Ave, Ste. 100 City: Seattle State: WA Zip: 98101 Phone: (206) 962-6895 Fax: Email: elle.reinhard@mg2.com New Tenant: ❑ Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 600,000 Scope of Work (please provide detailed information): Age, condition and operational enhancements of the base building and guest experience. Sales floor and various departments remodeled. No major electrical distribution revisions. Will service be altered? ❑ Yes m No Adding more than 50 amps? FL Yes ❑ No Type of Use: Retail Type of work: ❑ New 0 Addition ❑ Service Change 21 Remodel ❑ Low Voltage ❑ Generator 0 Fire Alarm ❑ Telecommunication Property Served by: I1 Puget Sound Energy ❑ Seattle City Light W:U'ermit Center Applications -Handouts \Permit Applications \PDF's\Electrical Permit Application Revised 1-1-17 docx Revised: January 2017 bh ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014.EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: Print Name: Scott Owen Day Telephone: (206) 962-6500 09/01/2017 Mailing Address: 1101 Second Ave, Ste. 100, Seattle WA 98101 City W:\Permit Center\Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised 1-I-17.docx Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $5,084.22 EL17-0694 Address: 301 STRANDER BLVD Apn: 2623049005 $5,084.22 ELECTRICAL $4,842.11 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $4,842.11 TECHNOLOGY FEE $242.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13141 R000.322.900.04.00 0.00 $242.11 $5,084.22 Date Paid: Wednesday, January 03, 2018 Paid By: KEN BOBKO ELECTRIC CO INC Pay Method: CHECK 31414 Printed: Wednesday, January 03, 2018 11:34 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $19,753.66 D17-0245 Address: 301 STRANDER BLVD Apn: 2623049005 $17,553.14 DEVELOPMENT $17,553.14 PERMIT FEE R000.322.100.00.00 0.00 $4,710.15 PLAN CHECK FEE R000.345.830.00.00 0.00 $12,842.99 EL17-0694 Address: 301 STRANDER BLVD Apn: 2623049005 $1,726.01 ELECTRICAL $1,726.01 PLAN CHECK FEE 1 R000.345.832.00.00 0.00 $1,726.01 M17-0125 Address: 301 STRANDER BLVD Apn: 2623049005 $321.26 MECHANICAL $321.26 PLAN CHECK FEE R000.322.102.00.00 0.00 $321.26 PG17-0111 Address: 301 STRANDER BLVD Apn: 2623049005 $153.25 GAS $24.86 PLAN CHECK FEE 1 R000.322.103.00.00 0.00 $24.86 PLUMBING $128.39 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12372 R000.322.103.00.00 0.00 $128.39 $19,753.66 Date Paid: Wednesday, September 20, 2017 Paid By: MG2 Pay Method: CHECK 097536 Printed: Wednesday, September 20, 2017 2:53 1 of 1 PM CIIIIFIVSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Address: ALLt Type of Inspection: ,M Date Called: Special Instructions: Date Wanted: Requester: rki Phone No: Approved per applicable codes. LJ Corrections required prior to approval. 'COMMENTS: Inspector: fr\flt_ Dater / 3 /g REINSPECTION IEEE REQUIRED. Prior to next inspection, feemust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPE TION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: .....----- /A-4u4C?r Type of Inspection: 30 Address: i 0\ Date Called: Instructions: Date Wanted: 3/Special 7 p.m. Requester: I/ t Phone No: 2 ;7,2,f Approved per applicable codes. Corrections required prior to approval. COMMENTS: fk( ik4 ./ Dar To ' bad, (64,44,9 p44-641) 7 `a .- Alf5Adki PPI-dep a‘k r * Inspector: (71/161. REINSPECTION F'jEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit RMIT NO. CITY OF TUKWILA BUILDING DIVISION4 6300 Southcenter Blvd_, #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: (206) 431-3 er Type of Inspection: Address: n / Secilli-^66C Date Called: Special Instructions: Date Wanted: Qv //I th,c;. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: r 11,/ I,- - A -c<5 1 e61 (;,(2,,D kr edry P r- 41/.19 ©r s' REINSPECTION FEE REQUIRED. Prior to next inspection. fee m st be Inspector: Date: paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD kr Retain a copy with permit INSPECTION NO. p ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367► Permit Inspection Request Line (206) 438-9350 Project: /144-116r Typ Ins ection: 4 r/e9 144 (Ai Address: Date Called. Special Instructions: Date Wanted: ( . . 3/C 61 m: 46 Requester: a Phone No: Z/133S01T�� ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: CiD,Inot" Al &WTI U-511vori 004) t4)) — Wim.. �4 A-cdttreptice-\ Dccu P1 6u`c-,--2pn► cc�1 Inspector: Date: oS otal� ins ection fe must REINSPECTION FEE REQUIRED. Prior to nextp be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. P'RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit inspection Request Line (206) 438-9350 Project: Type of Inspeydl�i AO /a Address:/ Date Called: Special Instructions: Approved per applicable codes. Date Wanted: Requester: Phone No: p.m. Corrections required prior to approval. COMMENTS: Inspector: Date: ©/re REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 _ Project:hype �,� C of In sp o D ciii/4- i'` it Address: 3 n ate Called: Special Instructions: (I- Date Wanted: a.m p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 9A_ (-,, (I- S C.,)/\11J11-3 AO Aro e A-1ed5 i °'16\ 5<‘Ii GC, I✓J ,I, - �f (56:,t Le C-6-14 i /--w Inspector: '/ C 64.461 Date: 0241 zit b REINSPECTION I`EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3679' Permit Inspection Request Line (206) 438-9350 Project: + Type of Inspection: 7 Address: /: 5 Q i )7 tiA1 Der Date Called: fir Special Instructions: �t (-'1J"4• l,.(�1 :� "fi U Pi i (,.WW :411/ C 44'3!Ci" Date Wanted: /? a.m. Requester: ' ► t Phone No: - 7a LAA.5 741 Approved per applicable codes. Corrections required prior to approval. COMMENTS: fir J 11,), Iz,�/17 7a LAA.5 /_AIt> rtorap 1cY '-' Lilts -kV X.0011 titoitt6 inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee mustbe paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD 6,47-061LIRetain a copy with permit INSPECTION NO. PMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 - Project: .../..- �I Type of Inspection: tp 11 Address: ( 51-11A011) Date Called: Special Instructions: Date Wanted: a:m: //DT Requester: Phone No: ;5,36g6it36 Q, ElApproved per applicable codes. E Corrections required prior to approval. COMMENTS: Rr Oi A t1`mfry ►inD` inspector:/ 6 ( / Date: D 10 i REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. DocuSign Envelope ID: 22E8079A-885D-46FE-9F3F2001A884A �J EXHIBIT "A" Attachment to Agreement No. 4217042-200.26.00, dated December 28, 2017, by and between KEN BOBKO ELECTRIC CO INC and Skanska USA Building Inc. for Electrical at Target T-0627 South Center, 301 Strander Blvd Tukwila, WA 98188. 37. Provide daily protection of exposed trenches to pedestrian and store personnel traffic including the use of barricades, plywood floor protection, etc., plywood to be flush with finish floor at the end of each shift. 38. Subcontractor is responsible for receiving, inventorying, storing, and installing all Owner supplied material/equipment for this scope of work. Shipping discrepancies need to be brought to Skanska's attention in writing within three (3) days of delivery. 39. Layout and coordination with other trades as required to complete all electrical work, including locations of equipment. 40. Subcontractor is required to have a Foreman present for all inspections. 41. Subcontractor to provide deferred submittals as necessary per G001. 42. Multiple mobilizations as required. 43. Hoisting for material and personnel. Scissor lifts will not be allowed to operate over new finish flooring. 44. Daily clean-up and removal of debris to on-site dumpster. 45. Subcontractor shall provide daily protection for existing surfaces/finishes. Subcontractor shall protect all existing work and/or property from damages during their installations. Any damage resulting from Subcontractor's performance shall be Subcontractor's sole responsibility to repair, replace, clean, and/or correct to original condition. 46. Subcontractor includes working one shift from 10:00 PM to 6:30 AM, Sunday through Thursday. Subcontractor understands that while this scope of work is being performed the store will remain fully operational and will limit the impacts to both the guestthe store team as much as possible. 2. Compilation of Subcontract Agreement 2.1. Base Bid: $378,452.00 2.2. Payment & Performance Bond: $9,461.00 2.3. Subcontract Amount: $387,913.00 3. Alternates The following are not included in the Subcontract Amount/Purchase Order Amount and are included in Exhibit C. 3.1. None 4. Exclusions The following items are specifically excluded from Scope of Work/Supply: 4.1. Washington State Sales Tax EL L7 O9' -i RECEIVED CITY OF TUKWILA JAN 03 2018 PERMIT CENTER Exhibit A, Page 3 of 3 Scope of Work/Supply and Clarifications/Qualifications Version 1.0 (06.2006 ed. Rev. 0) MG2 Corporation 1101 Second Ave, Ste 100 Seattle, WA 98101 11/21/2017 Rachelle Ripley, Permit Technician City of Tukwila Department of Community Development 6300 Southcenter Blvd, Ste 100 Tukwila, WA 98188 (206) 431-3670 RE: Target - T0627 Southcenter, WA 301 Strander Blvd Tukwila, WA 98188 Permit Number: EL17-0694 Subject: Plan Check Correction Sheet Response #1 Dear Rachelle Ripley, Below is a summary of revisions done for Target T0627 Southcenter, WA. All revisions are owner changes noted with a revision clouds and deltas. OWNER CORRECTIONS: • E001 o Updated General Notes per Target direction. o Updated sheet index. NOV 2 1 2017 o Updated Electrical Symbols List. • ED111 PERMIT CENTER o Added Mezzanine Lighting Demolition view. o Removed Starbucks lighting demolition scope per Target direction. o Existing Food Service Avenue lighting to remain per Target direction. o Modified demolition scope in Food service area per Store planning Direction. • ED211 o Updated Mechanical/Plumbing coordination per Target direction. o Updated Fire and Intrusion scope of work. o Removed Starbucks power & systems demolition scope. o Existing Food Service Avenue power & systems to remain per Target direction. o Modified demolition scope in Food service area per Store planning Direction. • E110 o Added Overall Lighting Coordination Plan sheet per Target direction. • E111 o AdddeAdeddeR Keynotes. o Riverwalk enlarged view per Target direction. REVISION N0, o Added enlarged view callouts per Target direction. o Modified sales floor lighting layout per Target direction. o Modified lighting layout in Food service area per Store planning Direction. o Added Microlite Arc circuiting in the Riverwalk feature per store planning direction. • E121 206 962 6500 MG2.com RECEIVED CITY OF TUKWILA o Updated Keynotes. o Revised enlarged views/callouts per Target direction. • E122 o Updated Keynotes. o Revised enlarged views per Target direction. o Revised Track Connector Legend per Target direction. o Modified lighting layout and circuitry in Liquor Aisle per A/E Prime & Target Electrical Direction. • E124 o Updated Keynotes. o Revised enlarged views per Target direction. o Revised Track Connector Legend per Target direction. • E125 o Updated Keynotes. o Revised enlarged views per Target direction. o Revised Track Connector Legend per Target direction. • E131 o Removed Starbucks Lighting scope per Target direction. o Removed Starbucks Lighting Dimension scope per Target direction. o Modified lighting and mirror lights layout in Restrooms per A/E Prime & Target Electrical Direction. o Modified light fixture type "D11" to "D17" in Restrooms per A/E Prime & Target Electrical Direction. o Modified Restroom Lighting Dimension Plan per A/E Prime & Target Electrical Direction. o Added Keynote 220. o Updated Guest services lighting per Target direction. o Modified lighting layout in Food service area per Store planning Direction. • E141 o Added Mezzanine Office lighting plan per Target direction. o Added General & Keynotes as indicated. • E201 o Added Sales Floor Underfloor plan per Target direction. o Added General & Keynotes as indicated. • E211 o Updated Fire and Intrusion scope of work. o Removed Coiling Trucker's Door scope per Architectural direction o Updated Toys per Target direction. o Updated Keynotes. o Revised exterior signage PDB locations per Target direction. o Revised mechanical VAV scope of work. o Revised TVS scope of work per Target direction. • E221 o Revised Mech/Refr scope of work per Target/Target electrical direction. o Removed Starbucks Condensing Unit (AC -4B) scope per Target direction. • E311 o Removed Starbucks power & systems scope per Target direction. o Removed Starbucks & Food Service Equipment Schedules as part of scope per Target direction. o Removed Starbucks Food Service Notes & Key Notes as part of scope per Target direction. o Modified power in Restrooms per A/E Prime & Target Electrical Direction. o Removed Relocated Electrical Food Service Equipment Schedule per A/E Prime & Target Page 2 of 4 Electrical Direction. o Added Hands Free Faucet power per A/E Prime & Target Electrical Direction. o Removed Fire Alarm Strobes in Restrooms per A/E Prime & Target Electrical Direction. o Added Key Note 957 as indicated. o Modified Key Note 961 as indicated. o Updated Fire and Intrusion scope of work. o Updated Office scope of work per Target/Target Electrical direction. o Added Promo future power & systems per Store planning Direction. • E321 o Revised power & systems in Offices area per Target/Target Electrical direction. o Relocated Mezzanine lounge TV power & systems per Store planning Direction. • E355 o Revised power & systems in Mezzanine EDC per Target/Target Electrical direction o Removed Coiling Trucker's Door scope per Architectural direction. • E370 o Revised Home power & systems area per Target/Target Electrical direction. o Updated Keynotes. • E381 o Revised E&E power & systems area per Target/Target Electrical direction. o Updated keynotes. o Updated Fire and Intrusion scope of work. • E382 o Revised Future Promo power per Target/Target Electrical direction. o Removed Promo future power & systems per Store planning Direction. • E385 o Revised Beauty Blowout power & systems per Target/Target Electrical direction. o Revised General notes & Keynotes per Target/Target Electrical direction. • E401 o Revised power & systems in Market area per Target Electrical Direction. o Updated Refrigeration/Freezer schedules. • E511 o Revised detail 22/E511. • E521 o Revised Details per Target direction. o Make detail 18/E521 Not Used as part of Starbucks scope per Target direction. • E531 o Updated Detail 21/E531 to NOT USED per Architectural direction. • E541 o Added Beauty Blowout Details per Target direction. • E601 o Modified Light Fixture Schedule per A/E Prime & Target Electrical Direction. o Modified Contactor Schedule per A/E Prime & Target Electrical Direction. o Revised Equipment schedules per MEP coordination. o Removed Electrical Water Heater (WH -11), Circulating Pump (CP -2) & Condensing Units (AC - 4A & AC -4B) Schedules as part of Starbucks scope per Target direction. • E611 o Removed Details per Target Electrical direction. o Clarified panel replacement scope per Target Electrical direction. o Added DCR scope of work per MEP coordination. o Revised Total Service Load summary due to removed Starbucks scope per Target direction. • E621 Page 3 of 4 o Revised Existing Panel Schedule HL -3, LPE-1, LP -1, LP -2A, LP -3 as indicated. • E622 o Revised Existing Panel Schedules LP -5, LP -6, LP -7, LP -9, LP -10, LP -13 as indicated. o Added Existing Panel Schedule LP -12B as indicated. o Updated circuit HL -2/23 KVA load as indicated. • E623 Revised New Panel Schedules LP -6A, LP -16. Should you require any additional information regarding this matter, please contact me at (206) 962- 6865. Thank you. Sincerely, kYL-f Elle Reinhar Project Manager f2J2t1Z011 Page 4 of 4 0 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0694 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BLVD DATE: 10/22/17 Original Plan Submittal X Revision # 1 before Permit Issued Issued Response to Correction Letter # Revision # after Perri DEPARTMENTS: tff- rklo Building Division Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMI NARY REVI EW: Not Applicable ❑ (no approval/review required) DATE: 10/28/17 Structural Review Required REVIEWERc6 INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 12/26/17 ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERQS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 12/18/2013 CPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0694 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # DATE: 09/20/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: c Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 09/20/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 10/19/17 ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11'ZI �2b�1 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # re, Revision # 1 be,-fPermit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Plan Check/Permit Number: EL,1T - (6c2sq Project Name: '(--u72. j Ce_vtir- . `v y,- Project Address: SSC (\STF— I L t k Uk. j A t WA JP) B Contact Person: tJLA, Phone Number: CZSk) ccjZ'ro8615 Summary of Revision: Pt SE S` . " PUIctV C _c5P—MET1(1VS t" RECEIVED KWILA NOV 21 2017 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit Center\Templates\Forms\Revision Submittal Formdoc Revised: August 2015 revision KEN BOBKO ELECTRIC CO INC c Horne Espanol Contact Search L&I Page 1 of 2 A -Z Index Help My 1,8d Safety & Health Claims & Insurance Workplace Rights 41111) Washington State Department of 16. Labor & Industries KEN BOBKO ELECTRIC CO INC Owner or tradesperson Principals BOBKO, KEN, PRESIDENT BOBKO, TAMI, VICE PRESIDENT BOBKO, KEN, AGENT Doing business as KEN BOBKO ELECTRIC CO INC WA UBI No. 601 481 263 PO BOX 7009 TACOMA, WA 98406-0009 253-756-0944 PIERCE County Business type Corporation Governing persons KEN EDWIN BOBKO TAMI LEE BOBKO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. KENBOEC066BA Effective — expiration 01/01/1994— 01/01/2020 Designated administrator ........................ BOBKO, KEN Active. Meets current requirements. License type License no. Master Electrician BOBKOK*962C4 Bond .............. WESTERN SURETY CO Bond account no. 60939377 Savings ........._.....__.. No savings accounts during the previous 6 year period. License Violations ...................._....................._....... No license violations during the previous 6 year period. $4,000.00 Effective date 01/01/1998 Expiration date Until Canceled Ai Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601481263&LIC=KENBOEC066BA&SAW= 1/3/2018 KEN BOBKO ELECTRIC CO INC IWorkers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 461,936-01 ................................ Doing business as KEN BOBKO ELECTRIC COMPANY INC Estimated workers reported Quarter 3 of Year 2017 "21 to 30 Workers" L&I account contact T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........... .......................................... No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................................................ No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 CO i Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601481263&LIC=KENBOEC066BA&SAW= 1/3/2018 Electrical Sheet Index Sheet Number Sheet Name E001 ELECTRICAL SYMBOL LIST & SITE PLAN ED111 LIGHTING DEMOLITION PLAN ED211 POWER & SYSTEMS DEMOLITION PLAN E111 LIGHTING PLAN E121 SPECIALTY LIGHTING PLAN E122 SPECIALTY LIGHTING ENLARGED PLANS E124 SPECIALTY TRACK LIGHTING PLAN E125 SPECIALTY TRACK LIGHTING PLAN 105A FITTING ROOMS E141 OFFICE LIGHTING PLAN 108A STAIRSA E201 SALES FLOOR UNDERFLOOR POWER 109 CIRCULATION E221 ROOF PLAN E311 ENTRY POWER & SYSTEMS PLAN E321 OFFICE POWER & SYSTEMS PLANS E355 ELECTRICAL DISTRIBUTION CENTER PLANS E370 HOME POWER & SYSTEMS PLAN E381 ELECTRONICS & ENTERTAINMENT POWER & SYSTEMS PLANS E382 CHECKLANE POWER & SYSTEMS PLAN E385 BEAUTY BLOWOUT POWER & SYSTEMS PLAN E401 MARKET AREA POWER & SYSTEMS PLAN E511 ELECTRICAL DETAILS E521 ELECTRICAL DETAILS E531 ELECTRICAL DETAILS E541 ELECTRICAL DETAILS E601 EQUIPMENT AND LIGHT FIXTURE SCHEDULE E611 ELECTRICAL ONE -LINE DIAGRAM E621 PANELBOARD SCHEDULES E622 PANELBOARD SCHEDULES E623 PANELBOARD SCHEDULES Room Names & Numbers Number Name 101 CARTS 101A ENTRY VESTIBULE 101B EXIT VESTIBULE 102 SALES 103 GUEST SERVICES 103A FLEXIBLE FULFILLMENT 104 CASH OFFICE 105 FITTING ROOMS 105A FITTING ROOMS 106 CIRCULATION 108A STAIRSA 108B STAIR B 109 CIRCULATION 111 AP OFFICE 112 CCTV 114 CONTROL ROOM 114 LOCKERS 115 WOMEN 116 MEN 119 JANITOR 125 ELECTRONICS STOCK 126 PHARMACY 127 PHARMACY RESTROOM 128 PHARMACY SALES 129 ELECTRICAL 130 COMPACTOR/BAILER 131 RECEIVING 133 MARKING 134 WATER SERVICE 139 NIGHT MAINTENANCE 140 DAY MAINTENANCE 141 CIRCULATION 142 FIXTURE STORAGE 143 WOMEN 144 MEN 148 STOCK 149 LPC 150 SHIPS LADDER 151 COATS 152 TEAM SERVICE CENTER 153 CIRCULATION 154 TSC STORAGE 155 ELECTRICAL 156 LPC 157 LOUNGE 158 TRAINING 160 STL OFFICE 161 ETL-HR 162 OPEN OFFICE 163 CONF 164 CONF 180 DAIRY COOLER 181 FREEZER 182 MEAT COOLER 183 PRODUCE COOLER 184 DRY PRODUCE LABELING ROOM 185 VACUUM PUMP 200 DISTRICT OFFICE 201 HRBP 202 DTL 203 SWING 204 STORAGE 205 EQUIPMENT ROOM 206 DTL 207 DTL 208 APBP 209 CONFERENCE 210 INVESTIGATION CENTER 212 OFFICE 213 OFFICE 214 TTS 215 LOUNGE 216 ENCLAVE 217 EVIDENCE LOCK-UP 218 MEN 219 WOMEN ELECTRICAL SYMBOL LIST n KEY NOTE O DESIGNATES OWNER SUPPLIED EQUIPMENT. REFER TQ SHEET A601 FOR OWNER FURNISHED EQUIPMENT SCHEDULE. 1-O O MI Mal Fat rLJ 0 MULTIPLE SYMBOLS ON BRACKET INDICATE ALL DEVICES UNDER ONE COVER PLATE. INCANDESCENT, HID, CFL OR LED LUMINAIRE LED LUMINAIRE FLUORESCENT LUMINAIRE TRACK LIGHT INDICATES EMERGENCY LIGHTING ILLUMINATED EXIT SIGN - CEILING/WALL (SHADED QUADRANT INDICATES FACE(S). PROVIDE DIRECTIONAL ARROWS WHERE INDICATED. POLE MOUNTED LUMINAIRE WALL MOUNT JUNCTION BOX -18" AFF UNO OR CABINET MOUNT JUNCTION BOX TAPE LIGHT REMOTE TRANSFORMER CEILING MOUNT JUNCTION BOX A = VIDEO DISTRIBUTION SYSTEM CRT = NETWORK SYSTEM E = ELECTRONIC POINT OF SALE (EPOS) SYSTEM F = FIRE ALARM SYSTEM P = PAGING SYSTEM S = SECURITY SYSTEM T = LOW VOLTAGE THERMOSTAT - 96" AFF UNO V1 = SINGLE 'F' CONNECTOR VIDEO DIST. COVERPLATE V2 = DUPLEX 'F' CONNECTOR VIDEO DIST. COVERPLATE OS = OCCUPANCY MOTION SENSOR SWITCH H = DOOR HOLDER PS = PHOTO SENSOR B'' SINGLE RECEPTACLE - 18" AFF UNO 071 DUPLEX RECEPTACLE - 18" AFF UNO (SSR - DENOTES SURGE SUPPRESSION) (GFCI - GROUND FAULT INTERRUPTER) (WP - WEATHER PROOF W/ WHILE IN USE COVER) QUADRUPLEX RECEPTACLE - 18" AFF UNO OPTIONAUEMERGENCY RECEPTACLE -18" AFF UNO OPTIONAUUPS RECEPTACLE - 18" AFF UNO 6-1 SPECIAL-PURPOSE RECEPTACLE - 18" AFF UNO SPLIT WIRE RECEPTACLE - 18" AFF UNO SPS - MULTIOUTLET ASSEMBLY, ARROWS DEFINE THE LIMITS OF THE INSTALLATION. RECEPTACLES 12" OC UNO W -LJ CLOCK HANGER RECEPTACLE - 84" AFF UNO A FLOOR BOX SYSTEMS (LETTER DENOTES OUTLET TYPE, SEE DETAILS) POWER POLE - LETTER DENOTES TYPE (a-1) - NUMBER DENOTES PRE MANUFACTURED CABLE KIT TYPE 4'a 2 SINGLE -POLE SINGLE -THROW SWITCH - 44" AFF UNO TWO -POLE SINGLE -THROW SWITCH - 44" AFF UNO c1 3 THREE-WAY SWITCH - 44" AFF UNO FOUR-WAY SWITCH - 44" AFF UNO rc► P SWITCH AND PILOT LIGHT - 44" AFF UNO NOTE: PILOT LIGHT IS ON WHEN SWITCH IS ON 644 K KEY -OPERATED SWITCH - 44" AFF UNO M = MOMENTARY CONTACT, SPDT HOA = HAND -OFF -AUTO SWITCH SC = SPEED CONTROL MSS = MOTOR STARTER SWITCH OS = OCCUPANCY (MOTION) SENSOR SWITCH D = DIMMER SWITCH (WATTAGE AS NOTED.) 00-1 TELEPHONE OUTLET - 18" AFF UNO WITH 3/4" EMPTY CONDUIT TO ABOVE SUSPENDED CEILING OR TO JOIST SPACE IN UNFINISHED SPACES. TELEPHONE OUTLET - 44" AFF UNO WITH 3/4" EMPTY CONDUIT TO ABOVE SUSPENDED CEILING OR TO JOIST SPACE JUNCTION BOX NO CLOSER THAN 4" FROM FINISHED DOOR FRAMEIN UNFINISHED SPACES. D-+ DATA OUTLET - 18" UNO WITH 3/4" EMPTY CONDUIT TO ABOVE SUSPENDED CEILING OR TO JOIST SPACE IN UNFINISHED SPACES. 31-1 TELEPHONE & DATA OUTLET - 18" UNO WITH 3/4" EMPTY CONDUIT TO ABOVE SUSPENDED •r • w14 SPA ES. CEILING MOUNTED STROBE CEILING MOUNTED HORN & STROBE DUCT MOUNTED SMOKE DETECTOR O CEILING MOUNTED SMOKE DETECTOR © MANUAL PULL STATION © ADDRESSABLE FIRE ALARM CONTROL MODULE FSAI ADDRESSABLE FIRE ALARM MONITOR MODULE 0 FIRE ALARM SYSTEM ANNUNCIATOR NOTE: DIMENSIONS ARE TO CENTERLINE OF DEVICE OR BOX UNO. "-v. Fop WATERFLOW SWITCH TAMPER VALVE SWITCH DOOR HOLDER BELL - 90" AFF UNO FE/ BUZZER - 90" AFF UNO Fl SPEAKER - CEILING FLUSH MOUNT CONTROL PANEL LP PANELBOARD HL PANELBOARD HP & LD PANELBOARD TRANSFORMER. ® MAGNETIC MOTOR STARTER SAFETY SWITCH (POLES NOTED, F INDICATES FUSED, SIZE AS NOTED). COMBINATION STARTER/SAFETY SWITCH PUSH BUTTON STATION MOTOR CONNECTION DAMPER MOTOR LINE VOLTAGE THERMOSTAT - 48" AFF UNO TEMPERATURE SENSOR, 96" AFF UNO R -NET SENSOR, 48" AFF UNO 11111111 T Ho HTS HRS 1 WIRING METHOD AND IDENTIFICATION (NOTE: WITHOUT FURTHER IDENTIFICATION SYMBOL INDICATES 1/2" CONDUIT WITH 2#12 AWG CONDUCTORS, CROSS LINES INDICATE QUANTITY OF #12 AWG CONDUCTORS AND EXTENDED CROSS LINE INDICATES NEUTRAL CONDUCTOR, LETTER "G" INDICATES SEPARATE GROUND (GROUND NOT SHOWN BY CROSS LINE), ALL IN CODE SIZED CONDUIT CONDUIT CONCEALED IN CEILING OR WALL CONDUIT CONCEALED IN FLOOR CONDUIT EXPOSED CONDUIT RUN UNDERGROUND (SLOPE TO DRAIN TO PULL BOXES). CONDUIT TURNED UP CONDUIT TURNED DOWN CONDUIT CAPPED OR BUSHED BRANCH CIRCUIT HOME RUN TO PANELBOARD LP -1 (UPPER CODE - PANEL ID, LOWER NUMERALS 1,2,3 IDENTIFY CIRCUIT NUMBERS) LPE-1/35 2#10 & #10G G 1.1"—A-14-7Cj ll\X T2-X T2 -X DEVICE WITH PANEUCIRCUIT INDICATOR AND SPECIAL WIRING REQUIREMENTS NOTED EQUIPMENT GROUND GROUND CONNECTION AS NOTED LOW VOLTAGE CABLE EXISTING TO REMAIN EXISTING TO BE DEMOLISHED NEW DEVICE INDICATES EXISTING DEVICE TO REMAIN. SYMBOLS WITH SLASHES THROUGH SYMBOL INDICATES EXISTING DEVICE TO BE DEMOLISHED AND/OR RELOCATED SYMBOLS SHOWN WITH LETTER "R" INDICATES RELOCATED DEVICE SYMBOLS SHOWN WITH STANDARD TEXT INDICATES NEW DEVICE EXISTING CONDUIT CONCEALED IN CEILING OR WALL TO BE DEMOLISHED EXISTING CONDUIT EXPOSED TO BE DEMOLISHED X = INDICATES TRACK CROSSOVER T2 -X = WHERE X INDICATES TRACK LENGTH IN FEET T = INDICATES TRACK "T" T2 -X = WHERE X INDICATES TRACK LENGTH IN FEET 5Ei''r.. .°ii'E PEMT REQUIRED FOR: Eif Mechanical 0 Electrical 121 Plumbing e(Gas Piping City of Tukwila BUILO! G DIVISION REVISIONS No changes shall be rude tothecope of work without prior approval ot Tukwila Bu!!ding Division. NOTE: Re,vis;c^s will require a r, :"1 plan submittal ditiono.l p'.cc and msy ;nc-'Ude c GENERAL NOTES FOR ALL SHEETS A. MATERIALS, PRODUCTS, DEVICES, FIXTURES, FORMS OR TYPES OF .,..ISfRUCTION INCLUDED IN THESE SPECIFICATIONS SHALL NALL.. OR EXCEED THE REQUIREMENTS OF NATIONAL ELECTRICAL CODE (NEC), AMERICAN NATIONAL STANDARD INSTITUTE (ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) AND NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION (NEMA). 13. MATERIALS AND EQUIPMENT SHALL BE LISTED AND APPROVED BY A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY AS CONFORMING TO THEIR STANDARDS. C WIRE, CABLES, AND INSULATIONS SHALL CONFORM TO ICEA- NEMA AND NATIONAL ELECTRICAL CODE STANDARDS AND SPECIFICATIONS. USE NEW WIRE AND DELIVER TO THE JOB SITE IN COILS OR ON REELS. EACH COIUOR REEL SHALL HAVE A LABEL WITH THE MANUFACTURER'S NAME, TRADE NAME OF WIRE, SIZE OF WIRE AND UL LABEL. D. INSTALL NEW CIRCUIT BREAKERS OR FUSES IN EXISTING PANELBOARDS AS REQUIRED TO FEED CIRCUITRY AS SHOWN ON PLANS OR SHOWN IN SCHEDULES. E. ANY FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. F. INSTALL NEW CIRCUIT BREAKERS WITH INTERRUPTING RATINGS MATCHING OR EXCEEDING THE RATING OF THE EXISTING EQUIPMENT. G. INSTALL OWNER FURNISHED CIRCUIT BREAKER (OFME E12) HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. H. REWORK (RE -ARRANGE) CIRCUIT BREAKERS WITHIN EXISTING PANELBOARDS TO ACCEPT NEW. LOAD CIRCUIT BREAKERS AS REQUIRED. I: EXISTING CIRCUIT NUMBERS ARE SHOWN FOR REFERENCE ONLY. CIRCUIT NUMBERS WERE OBTAINED FROM THE ORIGINAL CONSTRUCTION DOCUMENTS. FIELD VERIFY EXISTING CONDITIONS. J. COORDINATE POWER OUTAGES WITH TARGET'S OSR 24 HOURS IN ADVANCE. K. WHERE THE NUMBER OF CONDUCTORS IN CONDUIT OR CABLE EXCEEDS THREE (3), THE ALLOWABLE AMPACITY OF EACH CONDUCTOR HAS BEEN REDUCED PER TAB LE 310-15 (B)(2)(a). L. WHERE THE MAXIMUM AMBIENT TEMPERATURE IS OVER 30 DEGREES C. (86 DEGREES F.), APPLY CORRECTION FACTORS PER TABLE 310-16 TO 19. M. ALL ELECTRICAL EQUIPMENT AND WIRING SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY. INSTALLATION SHALL BE IN ACCORDANCE WITH APPROVED LISTING. N. EXIST SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC SECTION 1011.2) 0. ELECTRICALLY POWER EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924. (CBC SECTION 101t4) P. EMERGENCY POWER SUPPLY TO ILLUMINATED EXIT SIGNS FOR A DURATION OF NOT LESS THAN 90 MINUTES. Q. IN THE EVENT OF A POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY, CORRIDOR, AND EXTERIOR DOOR LANDING: .THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPEMTN, OR AN ON-SITE GENERATOR. INITIAL ILLUMINATION AVERAGE OF 1 FOOT- CANDLE AND A MINIMUM 0.1 FOOT-CANDLE AT FLOOR LEVEL. (CBC SECTION 1006.3) R. PERIODIC SEPCIAL INSPECTION IS REQUIRED DURING ANCHORAGE OF ELELCTRICAL EQUIPMENT FOR EMERGENCY OR STAND-BY POWER SYSTEM. (CBC SECTION 1006.3) FILE COPY Permit No. Vil/V IDALI. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and ,•n roe. is y Rrtowlecgod: REVISION NO.l.. Dat = ▪ ..4`3//,6/e City of Tukwila BUILDING DIVISION REVIEWED FOS. COMPLIANCE WITS NFPA 70 a NEC DEC 13 2017 C�. City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER CONSULTANT QUALITY ASSURANCE REVIEW DOCUMENTS REVIEWD BY: REVIEWERS PHONE: DATE REVIEWED: MODEL QUALITY REVIEWED BY: REVIEWERS PHONE: DATE REVIEWED: TROY KINCAID (208)577-5659 8/24/17 JAMES SANDERSON (208)577-5635 8/21/17 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn- By JLS Checked By JS/TK ELECTRICAL SYMBOL LIST & SITE PLAN E001 11/17/2017 3:46:59 PM 1 PRIVANCE HOSIERY f LIGHTING DEMOLITION PLAN �D111 SCALE: 1/16" = 1'-0" MEZZANINE OFFICE LIGHTING DEMOLITION PLAN E� D111� SCALE: 1/16" = 1'-0" (G.4) REVIEWED FOR COMPLIANCE WITH NFPA70mNEC DEC 13 2017 City ofTukwila BUILDING DIVISION ELII.0Vty RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK LIGHTING DEMOLITION PLAN ED111 11/17/2017 3:50:15 PM GENERAL NOTES A. B. C. D. E. F. G. H. I. J. K. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE PHASING OF DEMOLITION AND NEW CONSTRUCTION. REMOVE LIGHT FIXTURES, DEVICES, CONTROLS AND APPARTUS FROM AREA TO BE DEMOLISHED PER THIS SHEET AND ARCHITECTURAL Dl. VERIFY COUNT PRIOR TO BID. CAP OFF CONDUCTORS AND CLOSE JUNCTION BOXES. REMOVE ANANDONED CIRCUITS BACK TO PANELBOARD. THE CONTRACTOR SHALL REVIEW ALL MECHANICAL DRAWINGS FOR ELECTRICAL CIRCUITS, DEVICES, AND CONNECTIONS TO BE DISCONNECTED AND REMOVED FOR MECHANICAL EQUIPMENT TO BE ABANDONED. THIS SHALL INCLUDE AND LOW VOLTAGE CONTROLS. COORDINATE PROPER DISPOSAL OF ENTIRE LIGHT FIXTURE FLUORESCENT LAMPS, BALLAST'S, INTERNAL WIRING, METAL HOUSING ETC. WITH OSR. REMOVE CIRCUITRY BEING DEMOLISHED BACK TO SOURCE OR LAST ACTIVE DEVICE. IT IS THE INTENT OF THIS DRAWING TO PROVIDE SCOPE OF DEMOLITION REQUIRED. PROVIDE COMPLETE DEMOLITION AS REQUIRED TO FACILITATE NEW WORK INDICATED WITHIN CONTRACT DOCUMENTS. MAINTAIN CIRCUIT CONTINUITY TO ALL DEVICES FED DOWNSTREAM WHICH MAY BE INTERRUPTED DURING CONSTRUCTION. REMOVE CONDUIT AND WIRE ABANDONED DURING CONSTRUCTION. CIRCUIT NUMBERS SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CONDITIONS AT SITE. EXISTING JUNCTION BOXES AND HOMERUNS ARE SHOWN FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT LOCATIONS AND CIRCUITRY AT SITE. AREAS NOT INDICATED ON THIS SHEET ARE NOT IN SCOPE OF WORK AND REQUIRE NO WORK. REFER TO SHEET ED211 FOR DEMOLITION OF SPECIALTY LIGHTING ON SALES FLOOR FIXTURING. KEYNOTES # DESCRIPTION 207 INSTALL OWNER FURNISHED DOWNLIGHT RETROFIT KIT IN EXISTING LIGHT FIXTURE CAVITY, RECONNECT TO EXISTING CIRCUIT CONTROLS THAT HAVE BEEN RETAINED FROM REMOVAL OF EXISTING. 300 LIGHTING FIXTURES SHALL BE DISCONNECTED AND REMOVED AS INDICATED. COORDINATE WITH OWNER FOR PROPER DISPOSAL. 302 EXISTING SALES FLOOR FIXTURE VALANCE LIGHTS AND ANY ASSOCIATED POWER POLES SHALL BE DISCONNECTED AND REMOVED. COORDINATE WITH OWNER FOR PROPER DISPOSAL. 305 EXISTING LIGHT FIXTURE(S) WITHIN HATCHED AREA SHOWN ARE TO BE RELOCATED OR REMOVED. REFER TO NEW LIGHTING LAYOUT SHEETS FOR QUANTITIES OF RELOCATED LIGHT FIXTURES AND NEW LOCATIONS. VERIFY NEW LIGHT FIXTURE LOCATIONS WITH OWNER PROJECT MANAGER PRIOR TO DISPOSAL PER ELECTRICAL DEMOLITION SPECIFICATION SECTION 260020(2.1). 306 EXISTING LIGHTING CIRCUIT SHALL BE REMOVED BACK TO NEAREST JBOX ABOVE ACCESSIBLE CEILING SPACE AND RETAINED FOR RE -USE. 307 MAINTAIN CIRCUIT CONTINUITY FOR ALL REMAINING DOWNSTREAM LIGHT FIXTURES. EXTEND AND RE -CONNECT AS NECESSARY. 309 DISCONNECT AND REMOVE EXISTING LIGHTING CONTROL DEVICES AND CIRCUITRY ASSOCIATED WITH FIXTURES BEING DEMOLISHED. 310 MAINTAIN EXISTING LIGHTING CONTROLS. EXTEND AND RECONNECT AS NECESSARY TO MAINTAIN CONTROL OF LIGHT FIXTURES REMAINING AFTER DEMOLITION ACTIVITIES. 311 SEE SHEET E111 FOR NEW FIXTURE LAYOUT 312 SEE SHEET E121 FOR NEW FIXTURE LAYOUT 315 SEE SHEET E161 FOR NEW OCCUPANCY SENSOR LAYOUT. 1070 DISCONNECT AND REMOVE VALANCE LIGHTS, POWER POLES AND DEVICES IN GREETING CARDS. REFER TO 1/E211 FOR NEW GREETING CARD POWER LAYOUT. REVIEWED FOR COMPLIANCE WITH NFPA70mNEC DEC 13 2017 City ofTukwila BUILDING DIVISION ELII.0Vty RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK LIGHTING DEMOLITION PLAN ED111 11/17/2017 3:50:15 PM (G.4) (4\ 10891090 1092';' MEWS PERFORMANCE G.4 1066 SHOES POWER & SYSTEMS DEMOLITION PLAN SCALE: 1/16" = 1'-0" CD 1061 1069 1105 1106 (B� (B) /x./_.72 1081 RELOCATED DEVICE, REFER TO 1/E311 RELOCATED DEVICE(S), REFER TO 1/E311 6� KEYNOTES GENERAL NOTES DESCRIPTION GENERAL NOTES A. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE G. MAINTAIN CIRCUIT CONTINUITY TO ALL DEVICES FED DISCONNECT AND REMOVE EXISTING POWER POLE SERVING MINI ASSISTANCE CENTER (MAC). COORDINATE WITH LOW VOLTAGE VENDOR FOR REMOVAL OF DATA AND PHONE CABLE PRIOR TO POWER POLE REMOVAL. PHASING OF DEMOLITION AND NEW CONSTRUCTION. DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH JEWELRY. REMOVE FLOOR BOXES AND/OR CUT EXISTING UNDERFLOOR CONDUIT FLUSH WITH FLOOR AND COORDINATE SAW -CUTTING AND PATCHING OF FLOOR WITH GENERAL CONTRACTOR. REMOVE EXISTING CIRCUITRY BACK TO SOURCE. LABEL CIRCUITS IN PANELBOARD AS SPARE U.N.O. DOWNSTREAM WHICH MAY BE INTERRUPTED DURING B. REMOVE LIGHT FIXTURES, DEVICES, CONTROLS AND APPARTUS DISCONNECT AND REMOVE EXISTING POWER POLES AND DEVICES. VERIFY POWER POLES & CIRCUITS FOR REUSE ON POWER SHEETS. REMOVE THE REMAINING EXISTING CIRCUITRY BACK TO SOURCE AND PROPERLY DISPOSE OF EXCESS POWER POLES. CONSTRUCTION. REMOVE CONDUIT AND WIRE ABANDONED EXISTING POWER & SYSTEMS IN GUEST SERVICE COUNTER TO BE REMOVED. MAINTAIN CIRCUITS FOR RE -USE. REFER TO SHEET E311 FOR NEW. FROM AREA TO BE DEMOLISHED PER THIS SHEET AND DO NOT DEMOLISH CCTV, VOICE, DATA, SIGNAL CABLES IN THIS AREA. LOW VOLTAGE CONTRACTOR WILL VERIFY SOURCE AND DEMOLISH AS REQUIRED. DURING CONSTRUCTION. DISCONNECT AND REMOVE VALANCE LIGHTS, POWER POLES AND DEVICES IN GREETING CARDS. REFER TO 1/E211 FOR NEW GREETING CARD POWER LAYOUT. ARCHITECTURAL Dl. VERIFY COUNT PRIOR TO BID. CAP OFF H. CIRCUIT NUMBERS SHOWN ARE FOR REFERENCE ONLY AND REMOVE CIRCUITRY BACK TO SOURCE PANELBOARD AND LABEL CIRCUIT AS SPARE U.N.O. CONDUCTORS AND CLOSE JUNCTION BOXES. REMOVE REMOVE CIRCUITRY BACK TO NEAREST JBOX ABOVE ACCESSIBLE CEILING SPACE AND RETAIN FOR RE -USE. WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CONDITIONS DISCONNECT AND REMOVE EXISTING POWER AND SYSTEMS DEVICES ASSOCIATED WITH WALL(S) BEING DEMOLISHED. REMOVE CIRCUITRY BACK TO NEAREST REMAINING DEVICE. ANANDONED CIRCUITS BACK TO PANELBOARD. MAINTAIN CIRCUIT CONTINUITY FOR ALL REMAINING DOWNSTREAM DEVICES. EXTEND AND RECONNECT AS NECESSARY. AT SITE. C. THE CONTRACTOR SHALL REVIEW ALL MECHANICAL I. EXISTING JUNCTION BOXES AND HOMERUNS ARE SHOWN FOR DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH BEAUTY DEPARTMENT. RETAIN EXISTING CIRCUITING FOR RE -USE. REFER TO SHEET E385 FOR BEAUTY BLOWOUT LOCATION. DRAWINGS FOR ELECTRICAL CIRCUITS, DEVICES, AND DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH ENTRY DOORS, INCLUDING LOW VOLTAGE INTRUSION CONTACTS AND EXIT VIEW CAMERAS. RETAIN CIRCUITS FOR RE -USE. REFER TO NEW WORK SHEETS FOR NEW POWER REQUIREMENTS. REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. EXISTING POWER, SYSTEMS AND POWER POLES AT CHECKLANES TO BE REMOVED. RETAIN EXISTING CIRCUITS FOR RE -USE. REFER TO SHEET E382 FOR NEW CHECKLANE PLAN. CONNECTIONS TO BE DISCONNECTED AND REMOVED FOR EXISTING SELF CHECKOUTS AND ASSOCIATED POWER POLE TO BE RELOCATED. RE -USE EXISTING CIRCUIT TO FEED RELOCATED SELF CHECKOUTS. VERIFY EXACT LOCATIONS AND CIRCUITRY AT SITE. EXISTING POWER AND SYSTEMS FEEDING SALES FLOOR REFRIGERATION/FREEZER CASES TO BE REMOVED/ALTERED. REFER ALSO TO SHEET E401 FOR EXACT SCOPE OF WORK. MECHANICAL EQUIPMENT TO BE ABANDONED. THIS SHALL J. AREAS NOT INDICATED ON THIS SHEET ARE NOT IN SCOPE OF DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH BALER. RETAIN EXISTING CIRCUITING FOR RE -USE. REFER TO SHEET E211 FOR NEW LOCATION. INCLUDE AND LOW VOLTAGE CONTROLS. WORK AND REQUIRE NO WORK. D. COORDINATE PROPER DISPOSAL OF ENTIRE LIGHT FIXTURE K. REFER TO MECHANICAL DRAWINGS FOR DEMOLITION OF FLUORESCENT LAMPS, BALLAST'S, INTERNAL WIRING, METAL EXISTING MECHANICAL EQUIPMENT. COORDINATE WITH E. HOUSING ETC. WITH OSR. REMOVE CIRCUITRY BEING DEMOLISHED BACK TO SOURCE OR MECHANICAL CONTRACTOR. LAST ACTIVE DEVICE. F. IT IS THE INTENT OF THIS DRAWING TO PROVIDE SCOPE OF DEMOLITION REQUIRED. PROVIDE COMPLETE DEMOLITION AS REQUIRED TO FACILITATE NEW WORK INDICATED WITHIN CONTRACT DOCUMENTS. 10891090 1092';' MEWS PERFORMANCE G.4 1066 SHOES POWER & SYSTEMS DEMOLITION PLAN SCALE: 1/16" = 1'-0" CD 1061 1069 1105 1106 (B� (B) /x./_.72 1081 RELOCATED DEVICE, REFER TO 1/E311 RELOCATED DEVICE(S), REFER TO 1/E311 6� KEYNOTES # DESCRIPTION 300 LIGHTING FIXTURES SHALL BE DISCONNECTED AND REMOVED AS INDICATED. COORDINATE WITH OWNER FOR PROPER DISPOSAL. 636 DISCONNECT AND REMOVE EXISTING FIRE ALARM DEVICE(S). RETAIN DEVICE(S) FOR RELOCATION. SEE E211 FOR NEW LOCATION(S). REMOVE EXISTING CABLING COMPLETE BACK TO NEAREST REMAINING DEVICE. 1061 DISCONNECT AND REMOVE EXISTING POWER POLE SERVING MINI ASSISTANCE CENTER (MAC). COORDINATE WITH LOW VOLTAGE VENDOR FOR REMOVAL OF DATA AND PHONE CABLE PRIOR TO POWER POLE REMOVAL. 1063 DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH JEWELRY. REMOVE FLOOR BOXES AND/OR CUT EXISTING UNDERFLOOR CONDUIT FLUSH WITH FLOOR AND COORDINATE SAW -CUTTING AND PATCHING OF FLOOR WITH GENERAL CONTRACTOR. REMOVE EXISTING CIRCUITRY BACK TO SOURCE. LABEL CIRCUITS IN PANELBOARD AS SPARE U.N.O. 1065 EXISTING FITTING ROOM POWER & SYSTEMS TO BE REMOVED. REFER TO SHEET E211 FOR NEW. 1066 DISCONNECT AND REMOVE EXISTING POWER POLES AND DEVICES. VERIFY POWER POLES & CIRCUITS FOR REUSE ON POWER SHEETS. REMOVE THE REMAINING EXISTING CIRCUITRY BACK TO SOURCE AND PROPERLY DISPOSE OF EXCESS POWER POLES. 1067 EXISTING POWER & SYSTEMS IN GUEST SERVICE COUNTER TO BE REMOVED. MAINTAIN CIRCUITS FOR RE -USE. REFER TO SHEET E311 FOR NEW. 1069 DO NOT DEMOLISH CCTV, VOICE, DATA, SIGNAL CABLES IN THIS AREA. LOW VOLTAGE CONTRACTOR WILL VERIFY SOURCE AND DEMOLISH AS REQUIRED. 1070 DISCONNECT AND REMOVE VALANCE LIGHTS, POWER POLES AND DEVICES IN GREETING CARDS. REFER TO 1/E211 FOR NEW GREETING CARD POWER LAYOUT. 1081 EXISTING BUILDING SIGNAGE TO BE REMOVED AND REPLACED WITH NEW SIGNAGE. RETAIN EXISTING CIRCUITS FOR RE -USE. 1084 REMOVE CIRCUITRY BACK TO SOURCE PANELBOARD AND LABEL CIRCUIT AS SPARE U.N.O. 1087 REMOVE CIRCUITRY BACK TO NEAREST JBOX ABOVE ACCESSIBLE CEILING SPACE AND RETAIN FOR RE -USE. 1089 DISCONNECT AND REMOVE EXISTING POWER AND SYSTEMS DEVICES ASSOCIATED WITH WALL(S) BEING DEMOLISHED. REMOVE CIRCUITRY BACK TO NEAREST REMAINING DEVICE. 1090 MAINTAIN CIRCUIT CONTINUITY FOR ALL REMAINING DOWNSTREAM DEVICES. EXTEND AND RECONNECT AS NECESSARY. 1092 DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH ELECTRONICS/ENTERTAINMENT. REMOVE FLOOR BOXES AND/OR CUT EXISTING UNDERFLOOR CONDUIT FLUSH WITH FLOOR AND COORDINATE SAW -CUTTING AND PATCHING OF FLOOR WITH GENERAL CONTRACTOR. REMOVE EXISTING CIRCUITRY BACK TO PANELBOARD AND LABEL AS SPARE IF APPLICABLE. REFER TO REFER TO SHEET E381 FOR NEW POWER & SYSTEMS IN ELECTRONICS AND ENTERTAINMENT. 1095 EXISTING POWER AND SYSTEMS IN FOOD SERVICE AREA TO BE REMOVED. MAINTAIN CIRCUITS FOR RE -USE. REFER TO SHEET E311 FOR NEW SCOPE OF WORK IN THIS AREA 1098 DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH BEAUTY DEPARTMENT. RETAIN EXISTING CIRCUITING FOR RE -USE. REFER TO SHEET E385 FOR BEAUTY BLOWOUT LOCATION. 1099 DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH ENTRY DOORS, INCLUDING LOW VOLTAGE INTRUSION CONTACTS AND EXIT VIEW CAMERAS. RETAIN CIRCUITS FOR RE -USE. REFER TO NEW WORK SHEETS FOR NEW POWER REQUIREMENTS. 1105 EXISTING POWER, SYSTEMS AND POWER POLES AT CHECKLANES TO BE REMOVED. RETAIN EXISTING CIRCUITS FOR RE -USE. REFER TO SHEET E382 FOR NEW CHECKLANE PLAN. 1106 EXISTING SELF CHECKOUTS AND ASSOCIATED POWER POLE TO BE RELOCATED. RE -USE EXISTING CIRCUIT TO FEED RELOCATED SELF CHECKOUTS. 1107 EXISTING POWER AND SYSTEMS FEEDING SALES FLOOR REFRIGERATION/FREEZER CASES TO BE REMOVED/ALTERED. REFER ALSO TO SHEET E401 FOR EXACT SCOPE OF WORK. 1108 EXISTING POWER AND SYSTEMS FOR PET COOLER TO BE RELOCATED. REFER TO SHEET E211 FOR NEW LOCATION 1110 DISCONNECT AND REMOVE EXISTING ELECTRICAL ASSOCIATED WITH BALER. RETAIN EXISTING CIRCUITING FOR RE -USE. REFER TO SHEET E211 FOR NEW LOCATION. REVIEWED FOR COMPLIANCE WITH NFPA 70 a NEC DEC 13 2017 City of Tukwila BUILDING DIVISION LI'7.. ovty RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 GUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:VI3A Config:RL Drawn By JLS Checked By JS/TK POWER & SYSTEMS DEMOLITION PLAN ED211 11/17/2017 3:50:25 PM SR5C SR5B SR5C SR5B SR5C, 1 LIGHTING PLAN E111 1 SCALE: 1/16" = 1'-0" SALES FLOOR LIGHTING CONTROLS THE SALES FLOOR LIGHTING IS CONTROLLED BY AN ENERGY MANAGEMENT SYSTEM. SALES FLOOR LIGHTING IS DIVIDED INTO FOUR(4) EQUALLY SPACED PROGRAMS TO ENSURE EVEN LAMP BURN AND AN EVEN ILLUMINATED SALES FLOOR THAT CAN BE CONTROLLED IN 1/4 INCREMENTS. TEST THE SALES FLOOR EMS CONTROLLED LIGHTING SYSTEM TO VERIFY THE ALTERNATING ZONES AND ENSURE THAT THE FOUR (4) ALTERNATING ZONE PATTERN IS MAINTAINED AS SHOWN ON THIS SHEET. ON POWER LOSS, EMS TURNS ON EMERGENCY LIGHTS. "Cn I I nDn B.. A.. "Bn I I nAn nDn "C" 'D" 1 1 1 1..� non V nAn nEn ] "B" 1"C" "D" 1 ''c" I I nDn V l� ..B.. nAn n6nAn nDn C.. nDn I I "Cn PROGRAM "A -D": TYPE "AIL" IF ON EMERGENCY CIRCUIT (SHADED SYMBOL) TYPE "A2L" GENERAL NOTES A. REFER TO EMS CONTROL SCHEDULE ON SHEET E601 FOR NEW CONTROLLED CIRCUITS. MAINTAIN EXISTING CONTROLLED CIRCUITS, UNLESS NOTED OTHERWISE. B. REFER TO 1/E121 FOR SPECIALTY LIGHTS. C. LIGHT FIXTURE BRANCH CIRCUIT WIRING IS NOT INDICATED ON THIS DRAWING. ONLY HOME RUNS ARE INDICATED AT THE BEGINNING OF THE CIRCUIT. D. REFER TO SPECIFICATIONS FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. E. EXISTING SALES FLOOR 2' X 4' LIGHT FIXTURES ARE WIRED UTILIZING A MANUFACTURED WIRING SYSTEM. THE WIRING SYSTEM IS SUCH THAT EVERY OTHER FIXTURE IS ON ALTERNATE CIRCUITS. MARK FIXTURES WITH AN A OR B AS YOU REMOVE THE FIXTURES. REINSTALL FIXTURES SO THAT NO (2) LIKE FIXTURES ARE NEXT TO EACH OTHER IN A ROW. FIXTURES MUST ALTERNATE (A,B,A,B) TO MAINTAIN CORRECT CIRCUITING. F. ADJUST LIGHT FIXTURES AS REQUIRED FOR AREAS WITH SPRINKLER HEAD CONFLICTS. MAINTAIN 33 TO 5' SPACING FROM WALL AND 2' MINIMUM SPACEING BETWEEN FIXTURES. COORDINATE WITH ELECTRICAL ENGINEER IF THERE ARE MULTIPLE CONFLICTS. G. REFER TO SPECIFICATIONS FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. H. PROVIDE #10 WIRE FOR ALL EXIT LIGHTS AND FIXTURES ON EMERGENCY POWER. I. THE CIRCUIT NUMBERS SHOWN IS BASED ON AS -BUILT DRAWINGS. VERIFY EXACT CIRCUIT NUMBERS IN THE FIELD. J. INSTALL CEILING SUPPORT SYSTEM RODS OR WIRES (#12 MINIMUM) TO EACH CORNER OF EACH LIGHT FIXTURE, LOCATE NOT MORE THAN 6" FROM THE FIXTURE CORNER. K. REFER TO SHEET E601 FOR LIGHT FIXTURE SCHEDULE. L. VERIFY THE LOCATION OF EMERGENCY LIGHTS AT SITE. KEYNOTES # DESCRIPTION 9 LOCATE LIGHTS IN THIS ROOM NO CLOSER THAN 1'-0" FROM AIR FLOW EVAPORATOR DISCHARGE. 16 SURFACE MOUNT LIGHT FIXTURES ON BOTTOM SIDE OF COOLER/FREEZER PANEL UTILIZING MOUNTING BRACKETS SUPPLIED WITH LIGHT FIXTURE. FASTEN LIGHT FIXTURE MOUNTING BRACKETS TO COOLER/FREEZER PANEL WITH HILTI KWIK-PRO #12-14 HWH SELF -DRILLING SCREW - 3/4" IN LENGTH WITH ZINC COATED FINISH (OR EQUAL SELF -DRILLING SCREW). SEAL SCREW PENETRATION WITH TARGET APPROVED SEALANT. REFER TO 5/E531. 20 FIXTURES IN THIS ROOM ARE TYPE "C12" UNO. 25 CONNECT TO EXISTING CIRCUIT. EXTEND AND MODIFY CIRCUITRY AS NEEDED. 54 LIGHT FIXTURES IN THIS AREA SHALL BE TYPE '62L' U.N.O. 71 PROVIDE 277V CONNECTION FROM NEAREST VALANCE LIGHTING CIRCUIT IN THE AREA TO POWER OWNER FURNISHED MICROLITE BEAM LIT ELEMENT. CONTRACTOR TO INSTALL OWNER FURNISHED REMOTE TRANSFORMER EVERY 20 FT. ABOVE ACCESSIBLE CEILING. 122 MOUNT JUNCTION BOX ABOVE ACCESSIBLE FINISHED CEILING UNLESS NOTED OTHERWISE. 139 SUSPENDED 'RING' LED LIGHT. COORDINATE FINAL LOCATION WITH STORE FIXTURING/FLOORING NODE LOCATED BELOW. THE RING FIXTURE SHOULD BE CENTERED IN FLOORING NODE. LOCATION SHOWN IS NOT EXACT AND SHOWN FOR BIDDING PURPOSES ONLY. BOTTOM OF RING FIXTURE AS FOLLOWS: RP8 (2)=11'-6" AFF. RP12=12'6" AFF 142 INSTALL OWNER FURNISHED LED TAPELIGHT COVE LIGHTING OVER 'LAZY RIVER'. COVE LIGHTING TO BE CONNECTED TO EXISTING VALANCE LIGHTING CIRCUIT THAT WAS RETAINED FROM DEMOLITION OF EXISTING VALANCE LIGHTING. 143 TAPE LIGHT REQUIRES A REMOTE TRANSFORMER EVERY 20 FEET FOR THE ENTIRE LENGTH OF TAPELIGHT RUN. LOCATE TRANSFORMER ABOVE ACCESSIBLE CEILING. 170 RELOCATED 2x4 SALES FLOOR FIXTURE. PROVIDE CONNECTION FROM RELOCATED FIXTURE TO EXISTING FIXTURE/J-BOX. MAINTAIN EXISTING A,B,C,D PATTERN PER THE SALES FLOOR LIGHTING CONTROLS DIAGRAM ON THIS SHEET. VERIFY LOAD PRIOR TO FINAL CIRCUIT CONNECTION. 172 RELOCATED EMERGENCY 2x4 SALES FLOOR FIXTURE. 173 MAKE CONNECTION TO NEAREST EMERGENCY LIGHTING CIRCUIT IN THIS AREA. 17,. N_, I ' LI T - 'E 0 :x CI'C LEI 0 I. IN SA S Oo- LI ., TI C •C — R IT FIXTURES IN SUCH MANNER THAT THEY REPEAT EXISTING SALES FLOOR A,B,C AND D PATTERN. EXISTING SALES FLOOR CIRCUITS NOT TO EXCEED 12 AMPS. U.N.O. 672 APPROXIMATE LOCATION OF EXISTING HOMERUN. FIELD VERIFY AND COORDINATE EXISTING CONDITIONS. 721 CONNECTION TO EXISTING CIRCUIT LOCATED ABOVE CEILING RETAINED FROM DEMOLITION. FIELD VERIFY LOCATION OF EXISTING JUNCTION BOX. 897 COLUMN MOUNTED JUNCTION BOX LOCATED ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. SR5B SR5B 2RIVERWALK LIGHTING PLAN E111 1 SCALE: 1/8" = 1-0" REVIEWED FOR COMPLIANCE WITh NFPA70 - NEC DEC 13 2017 City of.Tukwila BUILDING DIVISION LIQ- Q6R4 RECEIVED CITY OF TUKWILA NOV 21 2011 :HERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/09/2017 7 DCN 1016151 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By KB Checked By JLS LIGHTING PLAN E111 11/17/2017 3:47:34 PM 18 (2 RING LIGHTING DIMENSION PLAN A&A 121 SCALE: 1/8" = 1-0" RING LIGHTING DIMENSION PLAN BEAUTY E121 SCALE: 1/8" = 1'-0" 217 VL4A 26.. VL4 33... VL2 33 HOUSEWARES pp-- ^� g�y� ``''--pp^^ Y.J:i19 E.R A IN 98• AYiW... E EC1 RONICS .tINI SEASO SEAS 0ua"A — VL4A 33 VL4 33'. (G.4) VL4A 35 rcr,�-.nw;s NFF € fil th • 11 IF cr,Gril AIRF J GY c1c c-c�,;c�E riICE VL4 'x/32 ?ori —103A C1.8 SPECIALTY LIGHTING PLAN SCALE: 1/16" = 1'-0" GENERAL NOTES A. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. B. VERIFY EXACT LOCATIONS OF SPECIALTY LIGHTING, CONDUIT AND POWER POLE WITH SHEET E211 POWER PLAN AND OWNER'S STORE FIXTURE REQUIREMENTS. C. INSTALL PRE MANUFACTURED WIRING SYSTEM BETWEEN J -BOX AND POWER POLE OFME E1 . KEYNOTES # DESCRIPTION 122 MOUNT JUNCTION BOX ABOVE ACCESSIBLE FINISHED CEILING UNLESS NOTED OTHERWISE. 126 PROVIDE J -BOX 12" ABOVE LAY -IN CEILING. PROVIDE FLEX CONDUIT CONCEALED IN WALL AND STUB OUT NEAR TOP OF FIXTURE MOUNTING BRACKET. SURFACE MOUNT FLEX CONDUIT ON TOP OF FIXTURE BRACKET AND MAKE CONNECTION TO OWNER FURNISHED VALANCE LIGHT. REFER TO 2/E531. 128 PROVIDE J -BOX ABOVE LAY -IN CEILING AND MOUNT TO TOP PLATE OF INTERIOR WALL. PROVIDE FLEX CONDUIT CONCEALED IN WALL AND STUB OUT CONDUIT ABOVE FIXTURE MOUNTING BRACKET ARM. SURFACE MOUNT FLEX CONDUIT ON FIXTURE BRACKET ARM AND MAKE CONNECTION TO VALANCE LIGHT. REFER TO 2/E531 AND 3/E531. 133 RELOCATED GREETING CARD FIXTURES. RE -INSTALL LIGHTING SIMILAR TO EXISTING. EXTEND CIRCUIT TO NEW LOCATION AS INDICATED. 139 SUSPENDED 'RING' LED LIGHT. COORDINATE FINAL LOCATION WITH STORE FIXTURING/FLOORING NODE LOCATED BELOW. THE RING FIXTURE SHOULD BE CENTERED IN FLOORING NODE. LOCATION SHOWN IS NOT EXACT AND SHOWN FOR BIDDING PURPOSES ONLY. BOTTOM OF RING FIXTURE AS FOLLOWS: RP8 (2)=11'-6" AFF. RP12=12'6" AFF 672 APPROXIMATE LOCATION OF EXISTING HOMERUN. FIELD VERIFY AND COORDINATE EXISTING CONDITIONS. 897 COLUMN MOUNTED JUNCTION BOX LOCATED ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. ALL LIGHT FIXTURES ARE SUPPORTED FROM STRUCTURE ABOVE ACT CEILING(S). EXISTING x4 RECESSED LED SALESFLO R TROFFER (TYPICAL) 1 TYPE SR5B, RECESSED (TYPICAL 0 r TYPE T2 SURFACE MOUNTED TRACK (TYICAL) 4 FOOT LONG _ED SLOTLIGHT F 5) TYPE SR5B, 4 FOOTLONG RECESSED LED SLOTLIGHT (TYPICAL OF 5) TYPE T2 SURFACE MOUNTED TRACK (TYPICAL) TYPE RP12, 12 FOOT DIAMETER RING PENDANT (TYPICAL) TYPE RP8, 8 FOOT DIAMETER RING PENDANT (TYPICAL OF 2) TOP OF SLAB 0'-0" TYPE LT1, CONTINUOUS LED COVE LIGHT MOUNTED WITHIN THE MICROLITE COVE SYSTEM CV I TYPE RP8, 8 FOOT DIAMETER RING PENDANT (TYPICAL OF 2) 4 1 N -S RING LIGHT SECTION DETAIL - TYPICAL TYPE RP12, 12 FOOT DIAMETER RING PENDANT E121 / SCALE: 1/4" = 1'-0" CEILING HEIGHT LAZY RIVER -14'-0" E -W RING LIGHT SECTION DETAIL - TYPICAL E121 / SCALE: 1/4" = 1'-0" REVIEWED FOR COMPLIANCE WITh NFPA 70 NEC - DEC 13 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By KB Checked By JLS SPECIALTY LIGHTING PLAN E121 11/17/2017 3:47:58 PM SP30 SP30 SP30, SP30 1 3 1 .1 3 a; -E- SP30 SP30 SP30 ,..:SP30 1 3 1 3 SP303P30 SP30 .SP30 SP30 SP30 .. SP30 1 3 1 3 1 3 1 SP30 SP30 SP30 SP30 3 1 3 1 SP10 7 SP10 5 SP10 7 T2-12 T2-12 T2H1 11 _ 11 11 11 ADULT BEVERAGE LIGHTING PLAN 3 122 SCALE: 1/4" = 1'-0" PROMO LIGHTING PLAN El 22 SCALE: 1/4" = 1'-0" HSW KITCHEN CORNER LIGHTING PLAN SCALE: 1/4" = 1'-0" SP3GSP30 SP30 SP30 3 1 3 1 SP10 H H '_.SP30 SP30 SP30_SP30 3 --- .,,..._........3 1 SP30 SP30 SP30: SP30 3..__ 1 :..___. 3 5 SP30...-.... SP30..-...SP30 SP30 3 1 H 3 B H. SP30 SP305P30 SP30 SP30 SP30 SP30 a,.H2...a SP30. SP30 SP30 _3- _.1..._ SP30 SP30 1 3 _. SP3OSP30 SP30 1 _34 1 -- #8 LP 7/5 LP -7/7 5,7 SP10 SP10 SP30SP3OSP30 SP30 —H H H H SP30 SP30 SP30 ` SP30 3 1 3 1 SP10 3 1 3 1 a SP30 SP30 SP30 3 1 3 -H : H H -H SP30 SP30 SP30 SP30 SP30 SP30 SP30 SP30 1 3 1 3 1 3 1 3 is fml 4 MARKET busSTRUT LIGHTING PLAN E122 SCALE: 1/4" = 1'-0" REVIEWED FOR COMPLIANCE WITH NPPA70 o NEC DEC 13 2011 City of Tukwila BUILDING DIVISION ELn 0 q1-4 RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT G N E. 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-.0627 Proto: P400 Version:V13A Config:RL Drawn By MS/KB/TR Checked By JS SPECIALTY LIGHTING ENLARGED PLANS E122 11/17/2017 3:48:04 PM GENERAL NOTES A. B. C. D. E. F. G. H. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. VERIFY EXACT LOCATIONS OF SPECIALTY LIGHTING, CONDUIT AND POWER POLE WITH SHEET E211 POWER PLAN AND OWNER'S STORE FIXTURE REQUIREMENTS. INSTALL PRE MANUFACTURED WIRING SYSTEM BETWEEN J -BOX AND POWER POLE (OFME El). INSTALL OWNER FURNISHED TRACK ON CEILING GRID SYSTEM UTILIZING FURNISHED T -GRID CLIP. INSTALL CLIPS PER MANUFACTURERS RECOMMENDATIONS. CONFLICTS IN GRID SYSTEM DUE TO MECHANICAL DIFFUSERS OR OTHER ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE TARGET OSR AND THE PROJECT ELECTRICAL ENGINEER. TRACK HEADS SHOWN ON THIS PLAN INDICATE GENERAL LOCATION PLACEMENT ONLY. FINAL AIMING OF THE HEADS WILL BE PERFORMED BY THE STORE TEAM. FULLY READ AND UNDERSTAND INSTALLATION INSTRUCTIONS PROVIDED WITH TRACK SYSTEM PARTS. TRACK JOINER T24WH CAN BE USED AS BOTH A STRAIGHT CONNECTOR AND AS AN "L" CONNECTOR. POLARITY OF THE CONNECTOR CAN BE FIELD MODIFIED. TRACK JOINER T25WH ISA "T" CONNECTOR, POLARITY OF THIS CONNECTOR CAN BE FIELD MODIFIED. TRACK JOINER T26WH IS AN "X" CONNECTOR, POLARITY OF THIS CONNECTOR IS FIXED. REFER TO TRACK CONNECTOR LEGEND FOR EXACT LOCATIONS. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. CIRCUIT BREAKER POWERING TRACK LIGHTING IS USED AS A DEVICE TO LIMIT THE CURRENT PER NED EXCEPTION 220.43(B) TRACK CONNECTOR LEGEND JUNO T24 WH "L" ADJUSTABLE CONNECTOR. JOINS TWO TRACK SECTIONS TO MAKE 90 DEGREE ANGLE. JUNO T25 WH "T" CONNECTOR. JOINS THREE TRACK SECTIONS TOGETHER. ' JUNO T26 WH "X" CONNECTOR. JOINS FOUR TRACK SECTIONS TOGETHER AT 90 DEGREE ANGLES. L T X KEYNOTES # DESCRIPTION • 67 USE A T35WH ADJUSTABLE JOINER FEED, CONFIGURED FORA 90 DEGREE ANGLE, FOR CIRCUIT FEED. THE FIRST TRACK SECTION ON EACH CORNER b RUN MAY NEED TO BE FIELD CUT TO FIT IN THE TRACK PATTERN. TERMINALS FOR TRACK CIRCUIT FEEDS ARE SIZED FOR #12AWG CONDUCTORS. PROVIDE #12 PIGTAIL FROM HOMERUN CONDUCTORS TO TRACK FEED TERMINALS. 68 RECTANGLE SYMBOL INDICATED ON PLAN EQUALS FLOOD TRACK HEAD LIGHT FIXTURE TYPE T2H2. USE 1 SYMBOL SHAPE SHOWN ON THIS PLAN TO DETERMINE 1 TRACK HEAD TYPE. 69 TRIANGLE SYMBOL INDICATED ON PLAN EQUALS A SPOT TRACK HEAD LIGHT FIXTURE TYPE T2H1. USE SYMBOL SHAPE SHOWN ON THIS PLAN TO DETERMINE TRACK HEAD TYPE. 1 70 TYPE SP3B AND SP3C SPOTLIGHTS SUSPENDED FROM STRUCTURE ABOVE ACT CEILING - AIRCRAFT CABLES TO EXTEND THROUGH CEILING TILES - TOP OF SLOT I FIXTURE TO BE AS CLOSE TO ACT AS POSSIBLE. 112 TYPICAL TRACK HEAD SPOT LIGHT (T2H1) INDIVIDUAL 1 TRACK HEAD CALLOUTS ARE NOT SHOWN. USE SYMBOL INDICATION TO DETERMINE IF TRACK HEAD IS SPOT OR FLOOD. 1 113 OWNER FURNISHED TRACK (WHITE IN COLOR). INSTALL 36 LINEAR FEET MOUNTED TO UNISTRUT. COORDINATE EXACT LOCATION PRIOR TO FINAL 1 INSTALLATION. 114 TRACK WITH SPOTS TO HIGHLIGHT END CAP. MOUNT TRACK ON CEILING GRID TS ROUGHLY 4 FEET FROM 1 END CAP FRONT. 122 MOUNT JUNCTION BOX ABOVE ACCESSIBLE FINISHED CEILING UNLESS NOTED OTHERWISE. 147 ARCHITECTURAL WOOD BEAM SYSTEM FURNISHED / AND INSTALLED BY OTHERS. 148 BUSSTRUT ELECTRICAL SYSTEM IS OWNER FURNISHED AND INSTALLED BY EC PER BUSSTRUT SHOP DRAWINGS AND ARCHITECTURAL PLANS. 149 INSTALL J -BOX ABOVE CEILING. CONNECT TO BUSSTRUT TRUNK FEED BY CONDUIT. REFER TO BUSSTRUT SHOP DRAWINGS FOR TRUNK FEED LOCATION. 173 MAKE CONNECTION TO NEAREST EMERGENCY LIGHTING CIRCUIT IN THIS AREA. 175 NEW LINEAR LIGHT FIXTURES TO BE CIRCUITED TO EXISTING SALES FLOOR LIGHTING CIRCUIT — CIRCUIT FIXTURES IN SUCH MANNER THAT THEY REPEAT EXISTING SALES FLOOR A,B,C AND D PATTERN. EXISTING SALES FLOOR CIRCUITS NOT TO EXCEED 12 AMPS. U.N.O. REVIEWED FOR COMPLIANCE WITH NPPA70 o NEC DEC 13 2011 City of Tukwila BUILDING DIVISION ELn 0 q1-4 RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT G N E. 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-.0627 Proto: P400 Version:V13A Config:RL Drawn By MS/KB/TR Checked By JS SPECIALTY LIGHTING ENLARGED PLANS E122 11/17/2017 3:48:04 PM • I LP -16 T2-12 T212 T2-12 %) T2-12 T2-12 T2-12 T2-12.:.: T2-12,65, 5 MT2-12 3 T2-12 T2-12 �4 �4 Y4 74 \4 T2-12 T2-12 T2-12 _..... 7 T2-12 34 T2 -8I 3 I L T2-12__;: 3 T2-12 T2_12 A �� �� E2 T2-12 b T2-12 T2-12 • 1 T2-12 1 T2-12 1 -T2-12 30 T2-4 �30 T2-12 1 T2-12 °'.68: TYP ACC T2-12 T2-8 T2-8 28 - 26 T2-8° 28 -T2-12-` 28 T2-12 1 T2-12 1 T2-8 --ET] 4.7 28 T2-12 1 T2-12 1'. T2-4 T2-12 T2-12 1 T2-12 1 T2-6 1.._ T212 T2-12 �2 T2-12 • 26 T2-4 T2-4 28 28 T2-8 28 . 7:\ T2-12 28 T2-4 T2-4 28 T2-4 28 T-.. 28 T2-12 1 T2-12 1 T2-12 1 T2 -12- T2-4 T2-8 30 LP -6A 28 65 66 T2-8 T2-8 34 34- T2-8 34 AA i5 T2-8 34 T2-8 T2-12 1 T2-12 1._ T2-12 1 _. LP -6A T2-12 34 34 •T2-12. T2-12 34 T2-8 34-- T2-12 34 T2-12',. T�'12 ................. ................... 34 34 1 SPECIALTY TRACK LIGHTING PLAN 125 / SCALE: 1/8" = 1.-0" REVIEWED EMANCE FOR COMPLIANCE NFPA 70 o NEC DEC 13 2011 City of Tukwila BUILDING DIVISION Ob114 RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING iTERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA co Co co 0) J F o co I..L W a Z �F- VJ r 0 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By KB Checked By JLS SPECIALTY TRACK LIGHTING PLAN E125 11/17/2017 3:48:12 PM GENERAL NOTES A. B. C. D. E. INSTALL OWNER FURNISHED TRACK ON CEILING GRID SYSTEM UTILIZING FURNISHED T -GRID CLIP. INSTALL CLIPS PER MANUFACTURERS RECOMMENDATIONS. CONFLICTS IN GRID SYSTEM DUE TO MECHANICAL DIFFUSERS OR OTHER ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE TARGET OSR AND THE PROJECT ELECTRICAL ENGINEER. TRACK HEADS SHOWN ON THIS PLAN INDICATE GENERAL LOCATION PLACEMENT ONLY. FINAL AIMING OF THE HEADS WILL BE PERFORMED BY THE STORE TEAM. FULLY READ AND UNDERSTAND INSTALLATION INSTRUCTIONS PROVIDED WITH TRACK SYSTEM PARTS. TRACK JOINER T24WH CAN BE USED AS BOTH A STRAIGHT CONNECTOR AND AS AN "L" CONNECTOR. POLARITY OF THE CONNECTOR CAN BE FIELD MODIFIED. TRACK JOINER T25WH ISA "T" CONNECTOR, POLARITY OF THIS CONNECTOR CAN BE FIELD MODIFIED. TRACK JOINER T26WH IS AN "X" CONNECTOR, POLARITY OF THIS CONNECTOR IS FIXED. REFER TO TRACK CONNECTOR LEGEND FOR EXACT LOCATIONS. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. CIRCUIT BREAKER POWERING TRACK LIGHTING IS USED AS A DEVICE TO LIMIT THE CURRENT PER NED EXCEPTION 220.43(B) TRACK CONNECTOR LEGEND JUNO T24 WH "L" ADJUSTABLE CONNECTOR. JOINS TWO TRACK SECTIONS TO MAKE 90 DEGREE ANGLE. JUNO T25 WH "T" CONNECTOR. JOINS THREE TRACK SECTIONS TOGETHER. JUNO T26 WH "X" CONNECTOR. JOINS FOUR TRACK SECTIONS TOGETHER AT 90 DEGREE ANGLES. L T X KEYNOTES # DESCRIPTION 65 CIRCUIT DIVIDING LINE FOR SINGLE CIRCUIT TRACK. TRACK ENDS OF SEPARATE CIRCUITS TO BE BUTTED TOGETHER WITH 1" TO 2" GAP. CIRCUIT INFORMATION SHOWN ON PLAN. 66 USE A T36WH T -BAR END FEED FOR CIRCUIT FEED. THE FIRST TRACK SECTION IN RUN MAY NEED TO BE FIELD CUT TO FIT IN THE TRACK PATTERN. TERMINALS FOR TRACK CIRCUIT FEEDS ARE SIZED FOR #12AWG CONDUCTORS. PROVIDE #12 PIGTAIL FROM HOMERUN CONDUCTORS TO TRACK FEED TERMINALS. 67 USE A T35WH ADJUSTABLE JOINER FEED, CONFIGURED FOR A 90 DEGREE ANGLE, FOR CIRCUIT FEED. THE FIRST TRACK SECTION ON EACH CORNER RUN MAY NEED TO BE FIELD CUT TO FIT IN THE TRACK PATTERN. TERMINALS FOR TRACK CIRCUIT FEEDS ARE SIZED FOR #12AWG CONDUCTORS. PROVIDE #12 PIGTAIL FROM HOMERUN CONDUCTORS TO TRACK FEED TERMINALS. 68 RECTANGLE SYMBOL INDICATED ON PLAN EQUALS FLOOD TRACK HEAD LIGHT FIXTURE TYPE T2H2. USE SYMBOL SHAPE SHOWN ON THIS PLAN TO DETERMINE TRACK HEAD TYPE. 69 TRIANGLE SYMBOL INDICATED ON PLAN EQUALS A SPOT TRACK HEAD LIGHT FIXTURE TYPE T2H1. USE SYMBOL SHAPE SHOWN ON THIS PLAN TO DETERMINE TRACK HEAD TYPE. 122 MOUNT JUNCTION BOX ABOVE ACCESSIBLE FINISHED CEILING UNLESS NOTED OTHERWISE. REVIEWED EMANCE FOR COMPLIANCE NFPA 70 o NEC DEC 13 2011 City of Tukwila BUILDING DIVISION Ob114 RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING iTERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA co Co co 0) J F o co I..L W a Z �F- VJ r 0 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By KB Checked By JLS SPECIALTY TRACK LIGHTING PLAN E125 11/17/2017 3:48:12 PM /3 PHARMACY RESTROOM LIGHTING PLAN E131 l SCALE: 1/4" = 1'-0" LP -6A/35 O 30" LP -6A/35 LP -6N35 /' �� •� 4'-11" PLP ` PLP,;' z 35 35 •' SLP -6N35 r O 30" FITTING ROOM LIGHTING PLAN SCALE: 1/4" = 1'-0" TYP 30" LP -6N35 d) 30" LP -6N35 LP -6A/35 PLP PLP 6'-8" a a rePLP PLP 0 PLP 35 35 35 LP -6N35 cp 30" PLP 35 HL -3/36 ‘SR1A- HL-3/36 SR113 .. HL -3/36 SR1B 38 HL -3/36 i TYP HL -3/36 15 FITTING ROOM LIGHTING PLAN \E131 SCALE: 1/4" = 1'-0" (4) HL -3/36 HL -3/36 HL -3/36 HL -3/36 -SR1A HL -3/36 GENERAL NOTES A. MAINTAIN CIRCUIT CONTINUITY TO ALL DEVICES FED DOWNSTREAM WHICH MAY BE INTERRUPTED DURING CONSTRUCTION. REMOVE CONDUIT AND WIRE ABANDONED DURING CONSTRUCTION. B. CIRCUIT EMERGENCY/EXIT LIGHTING (SHADED) TO PANEL HLE-1 (AS INDICATED). PROVIDE #10 WIRE FOR EMERGENCY AND EXIT LIGHTS C. CIRCUIT NUMBERS AND HOMERUNS SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CIRCUITS AT SITE. KEYNOTES # DESCRIPTION 18 REUSE EXISTING CIRCUIT IN AREA TO CONNECT NEW FIXTURES TO EXISTING DESIGNATED PANEL. 38 CONNECT TO SALES FLOOR VALANCE LIGHT FIXTURE CONTROLLED BRANCH CIRCUIT. VERIFY CIRCUIT CAPACITY TO ALLOW FOR ADDITIONAL LOAD. 43 INSTALL OCCUPANCY SENSOR/POWER SYSTEM (CI -205-1) IN CEILING. 45 PROVIDE OCCUPANCY SENSOR/POWER PACK WATTSTOPPER UT -300-2 IN CEILING TO CONTROL RESTROOM LIGHT FIXTURES. 52 CONNECT EMERGENCY LIGHTING TO NEAREST SALES FLOOR EMERGENCY LIGHTING CIRCUIT. EXTEND/MODIFY AS NEEDED. 56 PROVIDE CONNECTION TO EXISTING EMERGENCY CIRCUIT IN THIS AREA. 58 CONNECT NEW FIXTURE TO EXISTING CIRCUIT THAT SERVED FIXTURES REMOVED FROM THIS LOCATION DURING DEMOLITION PHASE. 130 INSTALL MIRROR LIGHTS PER RESTROOM ARCHITECTURAL INTERIOR ELEVATIONS ON SHEET A307. 168 RELOCATED LIGHT FIXTURE. CONNECT TO EXISTING BRANCH CIRCUIT. 207 INSTALL OWNER FURNISHED DOWNLIGHT RETROFIT KIT � y EXISTING CIRCUIT CONTROLS THAT HAVE BEEN RETAINED FROM REMOVAL OF EXISTING. 217 BOTTOM OF PENDANT LIGHT FIXTURE (PLP) 8'-6" AFF TYP. SENSOR WATTSTOPPER DT -300 SERIES TO CONTROL LIGHT FIXTURES. 224 PROVIDE SINGLE RECESSED RECEPTACLE CLOCK BOX OUTLET AT 30"AFF. CENTER OUTLET ON MIRROR. VERIFY FINAL LOCATION OF FITTING ROOM MIRRORS WITH FINAL FIXTURE PLAN AND FIXTURE DETAILS. 310 MAINTAIN EXISTING LIGHTING CONTROLS. EXTEND AND RECONNECT AS NECESSARY TO MAINTAIN CONTROL OF LIGHT FIXTURES REMAINING AFTER DEMOLITION ACTIVITIES. 672 APPROXIMATE LOCATION OF EXISTING HOMERUN. FIELD VERIFY AND COORDINATE EXISTING CONDITIONS. D17 I D22R D22R 0 ENTRY & STARBUCKS LIGHTING PLANS 1/4" = REVIEWED FOR COMPLIANCE WITh NFPA 70 0 NEC City of Tukwila BUILDING DIVIBION ELr7- SCALE: RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO C) J F MJ W W 0 Z �F— VJ C) Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JM/ Checked By JS/TK ENTRY LIGHTING PLANS E131 11/17/2017 3:48:20 PM 1 E141 GENERAL NOTES A. MAINTAIN CIRCUIT CONTINUITY TO ALL DEVICES FED DOWNSTREAM WHICH MAY BE INTERRUPTED DURING CONSTRUCTION. REMOVE CONDUIT AND WIRE ABANDONED DURING CONSTRUCTION. B. CIRCUIT NUMBERS AND HOMERUNS SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CIRCUITS AT SITE. C. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE PHASING OF DEMOLITION AND NEW CONSTRUCTION. KEYNOTES # DESCRIPTION 43 INSTALL OCCUPANCY SENSOR/POWER SYSTEM (CI -205-1) IN CEILING. 56 PROVIDE CONNECTION TO EXISTING EMERGENCY CIRCUIT IN THIS AREA. 912 APPROXIMATE LOCATION OF EXISTING HOMERUN. FIELD VERIFY AND COORDINATE EXISTING CONDITIONS. 43 43 MEZZANINE OFFICE LIGHTING PLAN SCALE: 1/4" = 1'-0" REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC DEC 13 2017 City of Tukwila BUILDING DIVISION_ EL -fl o6'!'f RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING lTERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By JS/TK OFFICE LIGHTING PLANS 11/17/2017 3:48:23 PM FLUORESCENT F1 !P AIM 550 FROM FLOOR TO ALLOW DEAD ZOO } LIGHT DUTY SHELVING 2 MOTION SENSOR MOUNTING DETAIL E161 SCALE: NOT TO SCALE n:3EAD r NE OOR CEILING 3" MUDRING HOLE CEILING ATTACHMENT RING OCCUPANCY SENSOR OCCUPANCY SENSOR MOUNTING SCREW, X2 OCCUPANCY COVER NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF CEILING MOUNTED MOTION SENSORS. CI -205-1 SENSOR CEILING TILE MOUNTING SCALE: NOT TO SCALE NEUTRAL LIGHT DUTY SHELVING - END VIEW MOTION SENSOR MOUNTING DETAIL SCALE: NOT TO SCALE TO POWER PACK C C \s////////// //7 1-- 4" X 4" JUNCTION BOX JUNCTION BOX COVER 1/2" CEILING TILE OCCUPANCY SENSOR OCCUPANCY SENSOR MOUNTING SCREW, X2 OCCUPANCY COVER NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF CEILING MOUNTED MOTION SENSORS. 3 -WAY SWITCHES o� TRAVELERS WHT HOT BLK 13 RED POWER PACK T RED 0 w J CO —J CO LOAD CONTROL OUTPUT COMMON +24VDC . ANY 24VDC • CLG/ WALL • ,SENSOR , MOTION SENSOR LOW VOLTAGE WIRING DIAGRAM FOR 3 -WAY SWITCHING E161 SCALE: NOT TO SCALE FS -C1 10' RJ45 CABLE IN BLACK SLIT LOOM FLEXIBLE TUBING - PROVIDED BY CASE VENDOR, INSTALLED BY ELECTRICAL CONTRACTOR 17 FS -705 SENSOR COOLER MOUNTING FS -05 RJ45 COUPLER - PROVIDED BY CASE VENDOR, INSTALLED BY ELECTRICAL CONTRACTOR J -BOX - PROVIDED AND INSTALLED BY CASE VENDOR BZ - 100WM POWER PACK - PROVIDED AND INSTALLED BY CASE VENDOR FS -705 OCCUPANCY SENSOR - PROVIDED BY CASE VENDOR, INSTALLED BY ELECTRICAL CONTRACTOR. LOCATE SENSOR IN THE MIDDLE OF CASE FOR EQUAL COVERAGE ON EITHER SIDE. THE FRONT EDGE OF SENSOR SHOULD BE LOCATED AT THE FRONT EDGE OF CASE. MC CABLE - PROVIDED AND INSTALLED BY CASE VENDOR LED LIGHTS INSTALLED IN CASE BY CASE VENDOR. LED LIGHTS TO BE CONTROLLED BY MOTION SENSOR ON -STORE OPEN. ON -STORE CLOSE, EMS SYSTEM WILL TURN OFF LED CASE LIGHTS. E161 l SCALE: NOT TO SCALE C1-205-1 SENSOR HARD CEILING MOUNTING SCALE: NOT TO SCALE NEUTRAL LINE BLACK GROUND GREEN/YELLOW GROUND GREEN 1 120V/230V/277V GROUND 0 0 LOAD RED LINE VOLTAGE WIRING DIAGRAM 14FOR MOTION SENSOR TYPE PW -100 E161 1 SCALE: NOT TO SCALE NEUTRAL WHT HOT BLK RED POWER PACK T RED 0 w J m J CO CONTROL OUTPUT LLOAD COMMON +24VDC • • • ANY 24VDC CLG/ WALL SENSOR , LOW VOLTAGE WIRING DIAGRAM FOR 18\ MOTION SENSOR FITTING ROOM E161 1 SCALE: NOT TO SCALE SYMBOL LIST WATTSTOPPER: HB350-L1-B WITH HBEM3 AND HB LINE VOLTAGE ® WATTSTOPPER: HB300-L1-B WITH HBEM3 AND HBAA LOW VOLTAGE WATTSTOPPER: HB300-L1-B WITH LOW VOLTAGE • WATTSTOPPER: HB350-L1-B WITH LINE VOLTAGE o WATTSTOPPER: PW -10<E10) WATTSTOPPER: UW -10#10) D WATTSTOPPER: FS -70 HBEM3 SENSO HBEM3 SENSOE161J (E10) MAIN TRAVEL AISLE MOTION SENSOR MOUNTING DETAIL \161.) SCALE: NOT TO SCALE JUNCTION BOX (INSIDE OF WALL) ASP -211 DIP SWITCHES PW -100 UW -100 PIR LENS NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF WALL MOUNTED MOTION SENSORS. WALL MOUNTED MOTION SENSOR 9� DETAIL FOR TYPES PW -100 & UW -100 E\ 161 i SCALE: NOT TO SCALE NEUTRAL LINE BLACK NEUTRAL WHITE GROUND GREEN 1 120V/230V/277V GROUND 0 LOAD RED SINGLE SWITCH FOR USE WITH UW -100: LINE VOLTAGE WIRING DIAGRAM FOR MOTION SENSOR TYPE UW -100 E 161 / SCALE: NOT TO SCALE NEUTRAL HOT Y U g m w H 0 w HB350 HB350: MAX 800 WATTS @ 120VAC, 60 Hz MAX 1200 WATTS @ 277VAC, 60 Hz LINE VOLTAGE WIRING LOAD 10� DIAGRAM FOR MOTION SENSOR TYPE HB350 E161 / SCALE: NOT TO SCALE HIGH VOLTAGE (277V OR 120V) CONNECTION MADE INSIDE BOX 16\ POWER PACK NOTES: A. POWER PACK SHOULD NOT BE MOUNTED WITHIN FOUR FEET OF SENSOR B. ALL SWITCHES ARE LOCATED ON THE LOAD SIDE OF THE POWER PACK E161 l SCALE: NOT TO SCALE NO ADJUSTABLE KNUCKLE LUMINAIRE SIDE MOUNT STRAIGHT TDa ' MOTION SENSOR MOUNTING DETAIL SCALE: NOT TO SCALE NEUTRAL AAI KNUCKI '- ADJUST' WHT HOT BLK RED LOCAL OFF SWITCH POWER PACK T RED w03 0 J m J CO CONTROL OUTPUT LOAD COMMON +24VDC LOW VOLTAGE WIRING • • • ANY 24VDC CLG/ WALL SENSOR DIAGRAM FOR SINGLE MOTION SENSOR SCALE: NOT TO SCALE AIM ANGLED MOTION SENSOR MOUNTING DETAIL SCALE: NOT TO SCALE NEUTRAL WHT HOT BLK RED POWER PACK T RED 0 w J CO J m CONTROL OUTPUT LOAD COMMON +24VDC CONTROL OUTPUT • • • 'ANY 24VDC CLG/ WALL ,SENSOR , COMMON +24VDC CONTROL OUTPUT • • • 'ANY 24VDC CLG/ WALL SENSOR COMMON +24VDC NOTE: MAXIMUM NUMBER OF 15 SENSORS PER POWER PACK 'ANY 24VDC CLG/ WALL ,SENSOR , LOW VOLTAGE WIRING DIAGRAM FOR MULTIPLE MOTION SENSORS SCALE: NOT TO SCALE OCCUPANCY SENSOR COVERAGE AREA. MASK SONSOR TO PROVIDE COVERAGE IN SHADED AREA ONLY. 20 OCCUPANCY SENSORS COOLER & FREEZER OCCUPANCY SENSORS E161 / SCALE: 1/16" = 1-0" ELflO9I REVIEWED FCS COMPLIANCE 'MI APPA 70 - KIP(' DEC 1 'fl17 City of Tukwila BUILDING DIVIS!C RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL co co r W 0) < s' 0 J ri M 1---- W1_4 U = m rimm Di -- a O z (I)(I) al- ce) Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JDP Checked By JLS OCCUPANCY SENSORS E161 11/17/2017 3:48:27 PM (5) 882 —_. LP -6N291 A :.:... #10 i 8'-0" 882 #10 882 #10 i 882 #10 LP -6A/27 A ` LP -6A/291 A LP -6N31 A #10 LP -6A/27 882 0 Co LP -6A/29 A LP -6A ( 1 SALES FLOOR UNDERFLOOR POWER PLAN 201 SCALE: 1/8" = 1.-0" REVIEWED FOP COMPLIANCE WITh NEPA 70 o NFC DEC 13 2011 City of Tukwila BUILDING DIVISIOP' EL1 O 6R9 RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JM Checked By JLS/TK SALES FLOOR UNDERFLOOR POWER 11/17/2017 3:48:30 PM GENERAL NOTES A. B. UNDER SLAB CONDUIT SHALL BE 3/4" MINIMUM, UNO. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. KEYNOTES # DESCRIPTION 686 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. 881 SAW CUT FLOOR AS REQUIRED. 882 PROVIDE FLUSH MOUNTED DECORATIVE FLOOR BOX WITH RECEPTACLE THAT CAN BE USED IN CARPET OR TILE. EXACT LOCATION MAY CHANGE. VERIFY LOCATION PRIOR TO ANY SAW CUTTING. SPECIFICATIONS: STEEL CITY 600 AL SC. STEEL CITY P60 DS AL. 883 PROVIDE FLOOR BOX UNDER GONDOLA TO MINIMIZE SAWCUTTING. ROUTE CONDUIT AND WIRE INSIDE GONDOLA BASE DECK AND THEN UP POWER POLE. REVIEWED FOP COMPLIANCE WITh NEPA 70 o NFC DEC 13 2011 City of Tukwila BUILDING DIVISIOP' EL1 O 6R9 RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JM Checked By JLS/TK SALES FLOOR UNDERFLOOR POWER 11/17/2017 3:48:30 PM • fv -T-13 LP -13 6) (8) 129 0841.! 2OS 133 HOUSEWARES SEASONAL DOMESTICS � m TOYS \ CCTV AFF:_ _._. LP -1/9 GA 1 \ POWER & SYSTEMS PLAN 14 yr DHU- 9 ON R OF NS BOYS 5110._ S HOSIER BA: NIT (NB) :.,l. E ..S) R T :;1 mac( yr IT \AI CARE H EATHC BE � 1.�. 5 PROD .:E LLP-10�.. ,... 11111111•11M • Mk .LP -1 2A - CE UNO) CCTV 9'-0" AFF TYP -q-43 A E211 / SCALE: 1/16" = 1'-0" REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION_ tLti ok, 6114 RECEIVED CITY' OF TUKWILA NOV 2 1 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By RS Checked By JLS OVERALL POWER AND SYSTEMS PLANS E211 11/17/2017 3:48:39 PM GENERAL NOTES A. B. C. D. E. F. G. H. I. J. K. L. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. UNDER SLAB CONDUIT SHALL BE 3/4" MINIMUM, UNO. INSTALL OWNER FURNISHED POWER POLE (OFME El) AND MANUFACTURED WIRING SYSTEM CABLE FROM J -BOX TO POWER POLES. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. REFER TO SHEET E521 FOR FLOOR BOX DETAILS. REFER TO 7/E531 AND 81E531 FOR TYPICAL POWER POLE INSTALLATION. REFER TO SPECIFICATIONS FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. REFER TO SPECIFICATIONS FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER CIRCUIT. REFER TO SPECIFICATIONS LOW VOLTAGE CABLE SUPPORT LOCATION. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING SYSTEM. REFER TO PRE MANUFACTURERS INSTALLATION DRAWINGS FOR INSTALLATION REQUIREMENTS. EXISTING JUNCTION BOXES, CIRCUIT NUMBERS AND HOMERUNS SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CONDITIONS AT SITE. KEYNOTES # DESCRIPTION 375 ROUTE CONDUIT DOWN THE MIDDLE OF THE BACK TO BACK HEAVY DUTY RACKING. 393 PROVIDE CONDUIT PATHWAY FOR EXTERIOR WALL MOUNTED CCTV CAMERA. PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE 3/4" CONDUIT FROM JUNCTION BOX TO EXTERIOR WALL MOUNTED CCTV CAMERA. STUB CONDUIT THRU EXTERIOR WALL AND CUT CONDUIT FLUSH WITH FINISHED WALL SURFACE. VERIFY EXTERIOR CCTV CAMERA LOCATION WITH VOICE/DATA LOW VOLTAGE CONTRACTOR. 397 PROVIDE 6' OF 3/4" FLEX CONDUIT TO CAMERA. VERIFY FINAL LOCATION WITH LOW VOLTAGE CONTRACTOR. 398 PROVIDE JUNCTION BOX AT 7'-6" AFF FOR CCTV CAMERA. MOUNT JUNCTION BOX ON END OF BULK RACKING. COORDINATE LOCATION WITH CCTV VENDOR. 607 PROVIDE AND INSTALL NEW DUCT DETECTOR FOR NEW HVAC UNIT. MATCH MANUFACTURE AND MODEL OF EXISTING DUCT DETECTORS. RECONNECT TO EXISTING MONITOR AND CONTROL CIRCUITS TO MATCH EXISTING. PROVIDE AND INSTALL NEW RTS AS REQUIRED. RECONNECT UTILIZING EXISTING CABLE. 631 MOUNT DEVICE TO UNDER SIDE OF DROP CEILING FEATURE. CONNECT TO NEAREST NOTIFICATION APPLIANCE CIRCUIT. 684 STUB CONDUIT (3/4" OR AS NOTED) FROM J -BOX TO AREA ABOVE CEILING LINE OR ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN UNFINISHED AREAS. 895 MOUNT RECEPTACLE IN GONDOLA BASE DECK. ROUTE CORD FROM DISPLAY TO RECEPTACLE. REFER TO 4/E531. 920 OWNER FURNISHED (PDB) POWER DISTRIBUTION BOARD FOR EXTERIOR SIGN. (PDB) INSTALLED BY SIGN VENDOR ABOVE ACCESSIBLE CEILING. PROVIDE POWER CONNECTION TO (PDB). PROVIDE JUNCTION BOXES BELOW ROOF DECK AND ABOVE ACCESSIBLE CEILING FOR EACH SIGN LETTER. PROVIDE 3/4" IMC BETWEEN JUNCTION BOXES AND EACH SIGN LETTER FOR ROUTING OF LOW VOLTAGE POWER CABLES. COORDINATE SIGN REQUIREMENTS WITH SIGN VENDOR ON SITE. 921 PROVIDE 3/4" IMC THRU EXTERIOR WALL FOR POWER CONNECTION TO EACH SIGN LETTER. COORDINATE EXACT LOCATION OF PENETRATION AND SIGN REQUIREMENTS WITH SIGN VENDOR AND GC. REFER TO 6/A142. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION_ tLti ok, 6114 RECEIVED CITY' OF TUKWILA NOV 2 1 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By RS Checked By JLS OVERALL POWER AND SYSTEMS PLANS E211 11/17/2017 3:48:39 PM (6 ROOF POWER & SYSTEMS PLAN L 876 877 878 DHU-1 —� 876 877 878 WP GFCI / U E221 SCALE: 1/16" = 1 '-0" REVIEWED COMPLIANCE WP ''' 70 DEC ^° 2~17. City ="'� Tukwila � BUILDING S"m RECEIVED TUKWILA,.r������ CITY 40v 2` ~-?ERIMIT CENTER - ELn (A 924 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 GUSHING TERRELL ARCHITECTS ENGINEERS www.ctag mup.mm 09/29/2017 10/16/2017 11/14/2017 11/21/2017 Description ��~�~°~°n x���x~°. , PERMIT ISSUE DCN 1014990 BID SET PERMIT RESUBMITTAL Project Number PFOtO:P4O0 Drawn By \/p[8iOO:\f13/\ Cnnfhg:Ri Checked By ROOF PLAN 11/17/2017 3:48:42 PM GENERAL �]����� NOTES A. B. C. D. E. F. ROUTE CONDUITS THROUGH ROOF WITHIN ROOF CURBS. ROUTE FEEDER CONDUITS FROM ELECTRICAL PANEL TO THE UNIT DISCONNECT (CIRCUIT BREAKER) FURNISHED WITH THE RTU. GROUND CONDUIT DIRECTLY TO JUNCTION BOX OF THE UNIT DISCONNECT (NOT JUST AT CONTROL CABINET). REFER TO 3/E521. PROVIDE 120 VOLT CIRCUIT AS INDICATED FOR DUPLEX GFCI RECEPTACLES FACTORY MOUNTED IN RTU'S. COORDINATE ROUGH -IN LOCATIONS WITH ALARM DRAWINGS. SEAL ALL CONDUIT PENETRATIONS TO BE WATERTIGHT AND AIRTIGHT, PER MANUFACTURER'S RECOMMENDATIONS. REFER TO 31E521. STUB 18" MINIMUM LENGTH CONDUIT FOR FIRE ALARM, AND 18" MINIMUM LENGTH CONDUIT FOR EMS, INTO CONTROL CABINET. SUPPORT WITHIN CABINET. PROVIDE BUSHINGS. REFER TO 31E521. KEYNOTES # DESCRIPTION 873 CONNECT TO EXISTING ROOF TOP RECEPTACLE CIRCUIT. MAINTAIN CONTINUITY OF EXISTING CIRCUITRY 876 DUCT SMOKE DETECTORS FOR THE DHU WILL BE LOCATED IN THE SUPPLY DUCT, THESE UNITS DO NOT HAVE RETURN DUCTS. 877 WHEN REMOVING EXISTING EMS WIRING FROM OLD UNIT, RETAIN CONDUITS AND WIRING. MAKE CONNECTION TO NEW UNIT SIMILAR TO EXISTING. COORDINATE WITH LOW VOLTAGE CONTRACTOR. 878 PROVIDE CONNECTION TO NEW REMOTE TEST STATION AS REQUIRED. UTILIZE EXISTING WIRING FROM OLD TEST STATION. REFER TO DETAIL 20/E531. E221 SCALE: 1/16" = 1 '-0" REVIEWED COMPLIANCE WP ''' 70 DEC ^° 2~17. City ="'� Tukwila � BUILDING S"m RECEIVED TUKWILA,.r������ CITY 40v 2` ~-?ERIMIT CENTER - ELn (A 924 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 GUSHING TERRELL ARCHITECTS ENGINEERS www.ctag mup.mm 09/29/2017 10/16/2017 11/14/2017 11/21/2017 Description ��~�~°~°n x���x~°. , PERMIT ISSUE DCN 1014990 BID SET PERMIT RESUBMITTAL Project Number PFOtO:P4O0 Drawn By \/p[8iOO:\f13/\ Cnnfhg:Ri Checked By ROOF PLAN 11/17/2017 3:48:42 PM G LP -9/36 40 LP -9 1,3 7'-8" 3'- 10" 12'-1" LP -9/40 721 LPE-1/15,17 721 1-1/4"C 1"C TYP 605 LP -9/1 \(11 cnUr� criLOUN I 1,1 ;tea\ UJ w 9 w w a s a a a CL LED POWER AO4. G, LP -9/38- 0 LP -6A 1"C w- w a a (3_ 27 LP -9/40 RELOCATED DEVICE LED POWER 30ctt— LED POWER L•-5/1,3 RELOCATED DEVICE RELOCATED DEVICE. LP -5 TYP /LP -4/21 OS 1018 721 1022 1022 SZ 11 1022 IFSAI r 75cd 605 LP -9/1 RELOCATED DEVICE 1 FOOD & GUEST SERVICES POWER & SYSTEMS PLAN E311 / SCALE: 1/4" = 1'-0" REVIEWED FOS COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2.1 2017 •ERP/IIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL CO 00 C70 rn QCt W J EtW Z W 0 H 0 (f) Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JM/MS Checked By J LS/TK ENTRY POWER & SYSTEMS PLAN E311 11/17/2017 3:48:46 PM GENERAL NOTES A. B. C. D. UNDER SLAB CONDUIT SHALL BE 3/4" MINIMUM. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER CIRCUIT. MOUNT JUNCTION BOXES ON STRUCTURE ABOVE CEILING. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. DEMOLITION KEYNOTES (OFFICE) ELECTRICAL DEVICES IN THIS AREA TO BE UNLESS NOTED OTHERWISE. MAINTAIN CIRCUITS CEILING FOR RE -USE. PROVIDE NEW DEVICES AS ANY DEVICES SHOWN WITH THIN LINES ARE TO ALL OTHERS TO BE REMOVED. ELECTRICAL DEVICES IN THIS AREA TO REMAIN. SHOWN WITH THIN LINES ARE EXISTING TO DEVICES SHOWN TO EXTEND TO EXISTING CIRCUIT DEVICES. A EXISTING REMOVED ABOVE INDICATED. REMAIN, B EXISTING C DEVICES REMAIN. TO NEW KEYNOTES # DESCRIPTION 25 CONNECT TO EXISTING CIRCUIT. EXTEND AND MODIFY CIRCUITRY AS NEEDED. 122 MOUNT JUNCTION BOX ABOVE ACCESSIBLE FINISHED CEILING UNLESS NOTED OTHERWISE. 605 RECONNECT EXISTING CIRCUITRY TO DOOR OPERATOR AND ALL OTHER DOOR DEVICES REQUIRING POWER IN NEW ENTRY DOORS. 608 RELOCATE EXISTING FIRE ALARM DEVICE. EXTEND EXISTING CIRCUIT TO NEW LOCATION. MATCH EXISTING CABLING. SEE ED211 FOR ORIGINAL DEVICE LOCATION. 610 PROVIDE FLUSH 1 -GANG BACKBOX AT 48" TO TOP OF FIRE ALARM DEVICE. STUB 3/4" CONDUIT INTO NEAREST ACCESSIBLE CEILING SPACE. 627 NEW FIRE ALARM NOTIFICATION DEVICE LOCATION. RELOCATE EXISTING DEVICE IF POSSIBLE. PROVIDE NEW DEVICE MATCHING EXISTING AS REQUIRED. PROVIDE CONNECTION TO NEAREST EXISTING FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT MAINTAINING CIRCUIT SUPERVISION CONFIGURATION AS REQUIRED BY NFPA 72. FIELD COORDINATE. 684 STUB CONDUIT (3/4" OR AS NOTED) FROM J -BOX TO AREA ABOVE CEILING LINE OR ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN UNFINISHED AREAS. 721 CONNECTION TO EXISTING CIRCUIT LOCATED ABOVE CEILING RETAINED FROM DEMOLITION. FIELD VERIFY LOCATION OF EXISTING JUNCTION BOX. 722 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. 724 PROVIDE PULL BOXES FOR POWER AND SYSTEMS UNDER BASE DECK AT EACH POS FIXTURE LOCATION, MOUNT PULL BOX ON TOP OF FINISHED FLOOR, BELOW FIXTURE ACCESS OPENING. CONNECT POS PREINSTALLED FLEXIBLE CONDUITS TO PULL BOXES. 730 SAW CUT FLOOR AS REQUIRED AND PROVIDE CONDUIT FOR LOW VOLTAGE CABLING, SIZE AS SHOWN. RUN CONDUIT FROM FLOOR BOX TO JUNCTION BOX ABOVE ACCESSIBLE CEILING. 731 SAW CUT FLOOR AS REQUIRED AND PROVIDE CONDUIT FOR RECEPTACLE POWER CIRCUITING, SIZE AS SHOWN. RUN CONDUIT FROM FLOOR BOX TO JUNCTION BOX ABOVE ACCESSIBLE CEILING. 732 RELOCATED FIRE AND BURGLAR ALARM REMOTE ANNUNCIATOR PANELS, MANUAL PULL STATION AND ASSOCIATED HARDWARE (BACK BOXES, MUD RINGS, ETC.) AT GUEST SERVICE. EXTEND EXISTING CIRCUITING AND CONDUITS TO NEW LOCATION. FIELD VERIFY ALL RELOCATED DEVICES. DEVICES ARE TO BE SAFELY STORED AND PROTECTED DURING CONSTRUCTION UNTIL REINSTALLED. 945 CONTROLLED RECEPTACLE: RECEPTACLE MUST BE MARKED TO DIFFERENTIATE THEM FROM THE UNCONTROLLED RECEPTACLES IN THE AREA. RECEPTACLE TO BE CONTROLLED VIA CEILING MOUNTED OCCUPANCY SENSOR. 956 INSTALL TOUCH FREE HAND DRYERS IN EACH TOILET ROOM. WIRE EACH DRYER WITH 1/2", 2 #12. FIELD VERIFY FINAL ARCHITECTURAL PLANS AND ELEVATIONS. REFER TO SPECIFICATION SECTION 26 7000. TYPICAL. 957 PROVIDE WALL MOUNTED GFCI RECEPTACLE BELOW SINK AND BEHIND ENCLOSURE TO CONNECT MANUFACTURER SUPPLIED 120V/9V PLUG-IN TRANSFORMER FOR SENSOR CONTROLLED TOUCH FREE FAUCETS. (3) THREE SENSORS (ONE PER FAUCET) CAN BE CONNECTED TO (1) ONE 120V/9V TRANSFORMER. 120V/9V TRANSFORMER AND LOW VOLTAGE WIRE CONNECTIONS FURNISHED BY SINK MANUFACTURER (ACORN ENGINEERING COMPANY). COORDINATE WITH PLUMBING CONTRACTOR AND MANUFACTURER INSTRUCTIONAL SHEETS FOR LOCATION OF .. ROUGH -IN. 958 PROVIDE (2) JUNCTION BOXES RECESSED IN WALL FOR AUTOMATIC TOUCH FREE TOILETS. COORDINATE WITH PLUMBING CONTRACTOR AND EQUIPMENT v°'"a. ¢; :._-"J1' 1. ]'.:'...or BOXES. COORDINATE WITH DIVISION 22 PRIOR TO ROUGH -IN. TYPICAL FOR ALL TOILETS. 961 PROVIDE 4" X 4" X 36" WIREWAY AND MOUNT WITH REMOVABLE COVER FACING OUT ABOVE ACCESSIBLE CEILING. DRILL KNOCKOUTS AND MOUNT SLOAN OPTIMA TOP OF WIREWAY. 963 PROVIDE (1) J -BOX RECESSED IN WALL FOR AUTOMATIC TOUCH -FREE URINALS. COORDINATE WITH PLUMBING CONTRACTOR & EQUIPMENT INSTRUCTIONAL SHEETS FOR LOCATION OF J -BOXES. COORDINATE WITH DIVISION 22 PRIOR TO ROUGH -IN. TYPICAL FOR ALL URINALS. 1018 CONTRACTOR TO FURNISH AND INSTALL WIRING FROM DEVICE TO LOCAL MODULE CABINET (HOMERUN). 1022 UTC RECESSED MAGNETIC 1078CW-N DOOR CONTACT. MOUNT ON INTERIOR FACE OF SIDE BREAKOUT PANEL. MAGNET MOUNTED ON EXTERIOR FACE OF SLIDER DOOR. E311 / SCALE: 1/4" = 1'-0" REVIEWED FOS COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2.1 2017 •ERP/IIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL CO 00 C70 rn QCt W J EtW Z W 0 H 0 (f) Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JM/MS Checked By J LS/TK ENTRY POWER & SYSTEMS PLAN E311 11/17/2017 3:48:46 PM 1 LP -9/34 PJ1 OS II -4 l!j) LP -9/32 152 A C.. r 7: 1;:671lret 111,-1 G1.1 ...,,iii.-.T...,i.‘.LP-9/34 600-1 '-'-- i OS [>-1 LP -9/10 ' ! 1 Gil , I" '''4- ...-0S...'.....-'!I ,.... LP -9/34 1 1,7111:9-9....§i23il, ...!G111 ' 1 TY- P-7 .i....\,r /'LP -9/2 LP -9/240=i1 Sbb4 8 os LP -9/34 151 A TYP 150 B MEZZANINE OFFICE POWER & SYSTEMS PLAN C /11 2:"L9/23 -4LC. 4.15 23 66"917PF-99/14 I-1!OSGF 27MICRO LP 9/327 RI )11 LMPI C-46 GFC LP -9/17 66"GFCI FUTURE 66" LP -9/37 FUTURE GFCI LP -9 17,23,35,37,39 A 157 4 OS GFCI LP -4/39 GFCI 60" 39 LP -4/41 GFCI !60" N LP -4 41 LP -4 687 fl 1-7 33: —3;—.................. , .3' 4::::‘ „7—., \ \ - . • 3 3 . 3 : : .. LP -4 LP -4/8 ;I LP -4/1 GFCI GFCI 60" 12 LP -9/13 153 A 6 '91 OS/USB *736"-; 1 1 . il 3 3t I i LP -414D OS/USB 1691- !!: 1 ; • : , . : . . . . • LP -9 13 LP -9 LP -9/13 KEYNOTES DESCRIPTION 684 STUB CONDUIT (3/4" OR AS NOTED) FROM J -BOX TO AREA ABOVE CEILING LINE OR ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN UNFINISHED AREAS. 687 CONNECTION TO EXISTING CIRCUIT LOCATED ABOVE CEILING RETAINED FROM DEMOLITION. FIELD VERIFY LOCATION OF EXISTING JUNCTION BOX. 691 MOUNT RECEPTACLE HORIZONTALLY. 930 PROVIDE JUNCTION BOX RECESSED IN WALL, 6" AFF, FOR ELECTRICAL IN FURNITURE SYSTEM. PROVIDE METAL COVERPLATE W/ CENTER KNOCKOUT. 931 PROVIDE POWER CONNECTION TO FURNITURE SYSTEM. FURNITURE SYSTEM USES TWO CIRCUITS. ELECTRICAL CONTRACTOR TO COORDINATE OUTLET LOCATIONS AND CONNECTIONS WITH FURNITURE VENDOR. 932 LOW VOLTAGE CONTRACTOR TO ROUTE TEUDATA CABLES IN FURNITURE RACEWAY AND PROVIDE DATA PLATE COVERS. 933 LOW VOLTAGE CONTRACTOR TO ROUTE TEUDATA CABLES IN FURNITURE SYSTEM RACEWAY TO 4 PORT FACE PLATE PROVIDED WITH FURNITURE SYSTEM. 934 INSTALL RECEPTACLES FURNISHED BY FURNITURE VENDOR. 935 PROVIDE CONNECTION TO DOOR STRIKE. 937 CONNECT TO TF -1 (TRANSFER FAN). 938 PROVIDE 2 -GANG JUNCTION BOX AT 44" AFF FOR TSC STORAGE DOOR STRIKE RELEASE PUSHBUTTON AND KEYSWITCH. PROVIDE 1/2 "C W/2#14 TO STRIKE SOLENOID. REFER TO SPECIFICATION SECTION 08 7100 HARDWARE GROUP 63 FOR PUSHBUTTON AND KEYSWITCH. 939 INSTALL POWER SUPPLY AND OTHER DEVICES FURNISHED WITH HARDWARE. PROVIDE CONDUIT, J -BOXES AND WIRING. 940 INSTALL JUNCTION BOX AT 18" AFF FOR MULITOUTLET ASSEMBLY. PROVIDE A 6-0" LONG MULTIOUTLET ASSEMBLY WITH SINGLE RECEPTACLE SPACING AT 6". MOUNT MULTIOUTLET ASSEMBLY VERTICALLY ON WALL. 942 PROVIDE 1"C FOR TELE/DATA CABLES AND 1"C FOR PAGING SYSTEM. 945 CONTROLLED RECEPTACLE: RECEPTACLE MUST BE MARKED TO DIFFERENTIATE THEM FROM THE UNCONTROLLED RECEPTACLES IN THE AREA. RECEPTACLE TO BE CONTROLLED VIA CEILING MOUNTED OCCUPANCY SENSOR. 946 RELOCATED CONTROLLED ACCESS EQUIPMENT (PUSHBUTTONS, INTERCOM, SWITCHES, ETC) SALVAGED FROM REMOVAL OF OLD TSC DESK. EXTEND EXISTING WIRING TO NEW LOCATION. COORDINATE EXACT LOCATION WITH OSR. 161 A LP -9 OS/USB /LP -4/5i LP -4/ H , TYP OS 1,.../ : OS LP -4/3 -0. I t - ,./;!!,;!, LP -4/5 - TYP LI ?"-.4156 }AIL, LP -4 7.: ../17 tI 34 OS/USB A 687 149 A 160 A LP -4/3 ir\s, , GOS/US!334" 687 1 LP -4 3 ft>PsH . , L HLP -4/3 37 ' P-4/3 k, 164 A 1-44. LP -4/1 _ 36" 136" LP -4/1 OS/USB, '36 1,, OS/USB 3 9466 945 I i_P-4 II,7.33,,,,..3...33=3.3333,3333.,T3,3.37=3I3 —3.3:30.33, C LP -4/4 <LP -9/15 C LP -9/42 ABOVE ACT -\TF-1 154 A LPE-1/12 LP -4124 687 D .13:3)3i LPE-1/12 C 940 114 . , .. 1..../ i1_P-4/33 - 'I ) LP -4/354 ••! (...--. ....., ,....,:::= , q,; H i osl •-••,,I,I 1 i ,?,:;"1"9-- 162 LP -4/35 LP -4/25 LP -4/33 A EF os LP -4/25 . 0S44"LP-4/33 Qt OS/USB 930 931 LP -4/31 ,OS11 945 TYP LLPP-4/ LP -4/31 /TLP -4/115 prA OS LP -4/36 -Tr@O S 1 -44P -1/P1 -41 OS/p44uSBll 61) 6847 932 930 687 L. 7936,38 sr:L...., LP -4/7 €;d11 11 OS'!! ! 1,1 932 930 6841 \ \ LP -4/38 LP -4/9 5 H vv../ TYP, LP -4/9 O 7is 44" LP -4/9 LP -4 Ocf7 6847 OS/USB,!!!!! 932 930 GENERAL NOTES A. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. B. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER CIRCUIT. C. REFER TO SHEET E521 FOR FLOOR BOX DETAILS. D. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. E. UNDER SLAB CONDUIT SHALL BE 3/4" MINIMUM. F. COORDINATE & FIELD VERIFY FINAL LOCATIONS OF ALL TOUCH FREE RECEPTACLES & BOXES WITH PROJECT ARCHITECT, ARCHITECTURAL PLANS AND ELEVATIONS. INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. G. REFER TO 7/E531 AND 8/E531 FOR TYPICAL POWER POLE INSTALLATION. H. REFER TO SPECIFICATIONS FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. I. REFER TO SPECIFICATIONS FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. J. REFER TO SPECIFICATIONS LOW VOLTAGE CABLE SUPPORT LOCATION. DEMOLITION KEYNOTES (OFFICE) A EXISTING ELECTRICAL DEVICES IN THIS AREA TO BE REMOVED UNLESS NOTED OTHERWISE. MAINTAIN CIRCUITS ABOVE CEILING FOR RE -USE. PROVIDE NEW DEVICES AS INDICATED. ANY DEVICES SHOWN WITH THIN LINES ARE TO REMAIN, ALL OTHERS TO BE REMOVED. EXISTING ELECTRICAL DEVICES IN THIS AREA TO REMAIN. DEVICES SHOWN WITH THIN LINES ARE EXISTING TO REMAIN. DEVICES SHOWN TO EXTEND TO EXISTING CIRCUIT TO NEW DEVICES. E321 SCALE: 1/4" = 1'-0" EL11 06414 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 1 3 2017 City of.Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT NTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 DCN 1014990 11/07/2017 4 DCN 1016064 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL ZONAL V, ! _ExpiR.Es 3 - ter ! Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By TR Checked By JS OFFICE POWER & SYSTEMS PLANS E321 11/17/2017 3:48:50 PM 60A D SCO NECT L'- LOAD SH �D RELAY EMFRGF CY ., i'C' I�v"v. ATS CONTAC CABINET 129 L.. ..., HL -z REAR EDC 129 POWER PLAN - FOR REFERENCE ONLY SCALE: 1/2" = 1'-0" 2C0.. Di SC i'NEH. 155 R_MS- NEON CONT ACTOR (AB:'': LIGHTING rONTACT REPLACES LP -12 MOUNTED TO EXISTING UNISTRUT. CONT CAB I !SCON;;:'.-CT LP -10 T-1 LC 2 FRONT MEZZ EDC 155 POWER PLAN E355 / SCALE: 1/2" = 1'-0" 148 C')-% STOCKROOM ENLARGED POWER PLAN SCALE: 1/2" = 1'-0" ELrio qq REVIEWED FOR COMPLIANCE WITH NFPA 70 - NPr' DEC 9817 RECEIVED ,.=ITY OF TUKWILA NOV 2 1 2017 )ERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DISTRIBUTION CENTER PLANS E355 11/17/2017 3:48:53 PM GENERAL NOTES A. B. C. D. WIRING BY EDC FABRICATOR SHALL ENTER AT BOTTOM OF PANELS, ETC. RESERVE RACEWAYS AT TOP FOR FIELD WIRING. COMPLY WITH NEC FOR WIREWAY FILL AT ANY CROSS- SECTIONAL AREA. PROVIDE JUNCTION BOXES FOR FIRE ALARM, SPRINKLER SUPERVISORY AND INTRUSION DEVICES. COORDINATE ROUGH -IN LOCATION WITH E900 SERIES DRAWINGS. BOXES FOR CEILING MOUNTED NOTIFICATION DEVICES SHALL BE FOUR SQUARE, DEEP, WITH MUDRING. REFER TO SHEET E701 FOR EMS WIRING DIAGRAM. KEYNOTES 525 PROVIDE CONNECTION TO MAIN CONTACTOR IN PANEL. UTILIZE SPARE RELAY IN EXISTING CONTACTOR CABINET AS SHOWN TO CONTROL CONTACTOR ON MAIN BUS OF NEW PANEL. REFER TO EMS CONTACTOR SCHEDULE ON E601. 148 C')-% STOCKROOM ENLARGED POWER PLAN SCALE: 1/2" = 1'-0" ELrio qq REVIEWED FOR COMPLIANCE WITH NFPA 70 - NPr' DEC 9817 RECEIVED ,.=ITY OF TUKWILA NOV 2 1 2017 )ERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DISTRIBUTION CENTER PLANS E355 11/17/2017 3:48:53 PM (4) DEMONSTRATION RCPT LP -2N3 LP -1 17,19,23 LP -1/30 LP -1/30 d LP -1/17 LP -1/30! LP -1/30 LP -2N1 CONNECTED HOME DOF\ d LP -1/17 - d LP -1/17 d LP -1/17 . LP -1/19 I c LP -1/19 �..a LP -1/21 !i T LP -1/23 LP -1/19 1— 0 J a L.,3 • D LP -6A 37,39,41 882 LP -6N39 LP -6N39 1 HOME POWER & SYSTEMS PLAN 370 SCALE: 1/8" = 1'-0" ICS ELnoh9 REVIEWED FOR COMPLIANCE WITH NFPA70 o NEr,,; DEC 13 2017 City of-Tukwi!& BUILDING DIVAI°'"-` RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By TNR Checked By JS HOME POWER & SYSTEMS PLAN E370 11/17/2017 3:48:56 PM GENERAL NOTES A. B. C. D. E. F. G. H. J. K. L. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. NOT USED. INSTALL OWNER FURNISHED POWER POLE (OFME El) AND MANUFACTURED WIRING SYSTEM CABLE FROM J -BOX TO POWER POLES. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. NOT USED. REFER TO 21/E521 AND 22/E521 FOR TYPICAL POWER POLE INSTALLATION. REFER TO SPECIFICATIONS FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. REFER TO SPECIFICATIONS FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. NOT USED. REFER TO SPECIFICATIONS LOW VOLTAGE CABLE SUPPORT LOCATION. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING SYSTEM. REFER TO PRE MANUFACTURERS INSTALLATION DRAWINGS FOR INSTALLATION REQUIREMENTS. EXISTING JUNCTION BOXES, CIRCUIT NUMBERS AND HOMERUNS SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM EXISTING PLANS. VERIFY EXACT CONDITIONS AT SITE. KEYNOTES # DESCRIPTION 686 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. 707 INSTALL OWNER FURNISHED POWER POLE TO TOP OF FIXTURE. VERIFY EXACT LOCATION OF POWER POLE 708 PROVIDE (3) 120V CIRCUITS AS INDICATED FOR FUTURE USE. MOUNT JUNCTION BOX 1'-0" ABOVE ACCESSIBLE CEILING. 881 SAW CUT FLOOR AS REQUIRED. 882 PROVIDE FLUSH MOUNTED DECORATIVE FLOOR BOX WITH RECEPTACLE THAT CAN BE USED IN CARPET OR TILE. EXACT LOCATION MAY CHANGE. VERIFY LOCATION PRIOR TO ANY SAW CUTTING. SPECIFICATIONS: STEEL CITY 600 AL SC. STEEL CITY P60 DS AL. 889 FUTURE CIRCUIT FOR JEWELRY TABLE DOWN LIGHTS. INSTALL, VERIFY WITH SPECIFIC REQUIREMENTS. STORE UNUSED POWER POLES WHERE DIRECTED BY OWNER. INSTALL FLEXIBLE WIRING CABLE FROM J -BOX TO THIS LOCATION, COIL ABOVE CEILING & ATTACH TO STRUCTURE FOR FUTURE USE. (OFME El B) 899 INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX 24" ABOVE ACCESSIBLE CEILING. 904 FLUSH MOUNT RECEPTACLE IN GONDOLA PANEL WALL, 6" ABOVE BASEDECK. PROVIDE FLEXIBLE METAL CONDUIT AND ROUTE VIA POWER POLE. CONCEAL CONDUIT BENEATH TOP RAIL OF GONDOLA. ELnoh9 REVIEWED FOR COMPLIANCE WITH NFPA70 o NEr,,; DEC 13 2017 City of-Tukwi!& BUILDING DIVAI°'"-` RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By TNR Checked By JS HOME POWER & SYSTEMS PLAN E370 11/17/2017 3:48:56 PM 1 CHECKLANES POWER & SYSTEMS PLAN E382 SCALE: 1/4" = 1'-0" 414 r ;�@ LP -3/34 (clx) LP 3/6 I/ w w 721 427 _P-3 2 3.25.2, 721 721 Jj LP -3 3.5.7 721 427 721 0 LP -3/27 LP -3/25_ _ I;LP-3/23 <� LP -3/23 414 (Clx) C C I/ww J J i LP -3/5 clx) L 'ww o_ o_ -11 J LP-3/5.YQ �� LPE-1/5 Pt 4E� LPE 1/7r LPE-1/5 J J LP -3/3 I1(c1x) M j;� I'% a Q_ J J LP-3/30;1(clx)� c 11[y•ww:� o_ o r;. J LPE-1/3 427 721 721 ( EL11 __ 069.4 REVIEWED FOR COMPLIANCE WITS NFPA 70 - NEC' DEC 13 2n17 City of.Ti ukila BUILDING_DIVISI ., rw._ RECEIVED 3ITY OF TUKWILA NUV 21 2017 ER:�IT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSI IING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JM Checked By JS/TK CHECKLANE POWER & SYSTEMS PLAN E382 11/17/2017 3:49:04 PM GENERAL NOTES A. B. C. D. E. F. G. H. I. J. UNDER SLAB CONDUIT SHALL BE 3/4" MINIMUM. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER CIRCUIT. MOUNT JUNCTION BOXES ON STRUCTURE ABOVE CEILING. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. CHECKLANE LIGHT FURNISHED WITH STORE FIXTURES BY SIGN VENDOR. CHECKLANE POWER POLES AND MOUNTING BRACKETS FURNISHED BY POWER POLE VENDOR. LANE LIGHT SOCKETS AND SWITCHES ARE PREWIRED BY VENDOR. PROVIDE SEPARATE NEUTRAL FOR EACH POS/SCANNER CIRCUIT (LPE-1). JUNCTION BOXES SHALL BE TRADE SIZE 411/16" X 21/8" SQUARE UNO. CHECKLANE WIRING SHALL BE #10 AWG CONDUCTOR THROUGHOUT ENTIRE BRANCH CIRCUIT. PROVIDE GROUND WIRE IN FLEX CONDUIT FOR CONVENIENCE AND COOLER CIRCUITS. KEYNOTES # DESCRIPTION 411 PROVIDE RECEPTACLE FOR MART -CART CHARGING. ROUTE CONDUIT CONCEALED IN FIXTURE WALL. 414 PROVIDE METAL FLEXIBLE CONDUIT WITH #10 WIRE FROM OWNER FURNISHED TERMINAL BOXES INSIDE CHECKLANE AND ROUTE VIA POWER POLE TO JUNCTION BOX LOCATED ABOVE CEILING. PROVIDE GROUND WIRE IN FLEX CONDUIT. REFER TO 16/E531 FOR ELECTRICAL LAYOUTS AND CONNECTIONS INSIDE CHECKLANE. 419 SURFACE MOUNT QUAD RECEPTACLE AND DATA J -BOX ON BACK WALL OF SELF CHECKOUT. DRILL FIXTURE WALL AS REQUIRED AND STUB FLEX INTO BACK QUAD J -BOX. DRILL 3/4" HOLE IN FIXTURE WALL BEHIND DATA J -BOX FOR LOW VOLTAGE CABLES. 422 PROVIDE METAL FLEXIBLE CONDUIT WITH #10 WIRE FROM OWNER FURNISHED TERMINAL BOXES INSIDE CHECKLANE AND ROUTE VIA POWER POLE TO JUNCTION BOX LOCATED ABOVE CEILING. PROVIDE GROUND WIRE IN FLEX CONDUIT. REFER TO 17/E531 FOR ELECTRICAL LAYOUT AND CONNECTIONS. 426 RECEPTACLE FOR SELF CONTAINED COOLER. UTILIZE ANY SPARE CIRCUIT RETAINED FROM REMOVAL OF EXISTING EQUIPMENT. CIRCUIT SHOWN IS BASED OFF OF AS BUILT CIRCUITING. 427 EXISTING CIRCUITING SHOWN FOR REFERENCE ONLY. UTILIZE EXISTING CIRCUITS RETAINED FROM DEMOLITION OF EXISTING CHECKLANES INDICATED ON SHEET ED211. 721 CONNECTION TO EXISTING CIRCUIT LOCATED ABOVE CEILING RETAINED FROM DEMOLITION. FIELD VERIFY LOCATION OF EXISTING JUNCTION BOX. EL11 __ 069.4 REVIEWED FOR COMPLIANCE WITS NFPA 70 - NEC' DEC 13 2n17 City of.Ti ukila BUILDING_DIVISI ., rw._ RECEIVED 3ITY OF TUKWILA NUV 21 2017 ER:�IT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSI IING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By JM Checked By JS/TK CHECKLANE POWER & SYSTEMS PLAN E382 11/17/2017 3:49:04 PM 500 Lri 60" ` LP -6A/11@=!, 60" r@ LP -6A/13 60,E I - LP -6A/11© 60" !Q LP 6A/13 I 60"I LP -6A/11 I 60" LP -6A/13 N 0 a J LP-6A/11©m 60" E® LP -6A/13 60" LP -6A/11 60" LP -6N13 (ax1) 499 TYP 497 588 502 497 502 501 500 502 497 LP -6N16,18 PS 502 LP -6A 493 9,10,11,13,12,14,15,17,19,21 500 --LP-6A120,22--- .PS 492 494 60" LP -6A/6 60" ® LP -6N8 60" LP -6N6 60" LP -6A/8 60"1 I LP -6N6 @? 11 60" I® LP -6A/8 60"Il LP -6N6 U 60" LP -6A/8 60" LP -6A/6 O 60" LP -6A/8 60" LP -6N6 11 60" LP -6A/8 LP -6A 1,3,2,4,5,7,6,8,16,18,20,22 500 LP -6N2,4 PS 499 TYP 493 500 - LP -6N1,3 PS 500 501 PROJECT LOCATED CEILING 492 494 LP -6 1,3,11,13,16,18,19,21 500: 493 492 494 LP -6 22,24,23,25,26,28 493 500 LP -6/11,13 1 BEAUTY BLOWOUT POWER & SYSTEMS PLAN 494 494 E385 / SCALE: 1/4" = 1'-0" 1 ELII __ 66 9i1 REVIEWED FOR CO�FP�70C��CTH DEC 13 2011 City of Tukwila BUILDING DIVIWIN, RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL EXPIRES .l8, -r CO CO rn Q Z W Y W 0--I = m D o O Q cf) Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JM Checked By JS/TK BEAUTY BLOWOUT POWER & SYSTEMS PLAN E385 11/17/2017 3:49:07 PM GENERAL NOTES A. B. C. D. E. F. G. H. HOMERUNS, WIRING AND DEVICES IN COSMETICS DEPARTMENT ARE PRE MANUFACTURED AND OWNER FURNISHED. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING SYSTEM. REFER TO PRE MANUFACTURES INSTALLATION E1 DRAWINGS FOR INSTALLATION REQUIREMENTS. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. REFER TO SPECIFICATION SECTION 27 9900 FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. REFER TO SPECIFICATION SECTION 27 9900 FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. REFER TO SHEET E383 FOR FLOOR BOX DETAILS. UNDER SLAB CONDUIT SHALL BE 1 " MINIMUM, UNO. KEYNOTES # DESCRIPTION 492 INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. 493 INSTALL PRE MANUFACTURED MAIN RUN CABLE FROM POWER DISTRIBUTION BOX TO PANEL IN EDC. 494 INSTALL PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN BASE DECK OF FIXTURE. 497 MOUNT PRE MANUFACTURED RECEPTACLE TO FIXTURE RAIL IN BASE DECK OF FIXTURE. REFER TO 10/E541. 499 MOUNT RECEPTACLE HORIZONTALLY IN PEG BOARD. REFER TO 8/E541. 500 INSTALL OWNER FURNISHED MULTI -OUTLET ASSEMBLY KIT PROVIDED WITH ALTERNATING CIRCUITS AND 20 AMP SIMPLEX RECEPTACLES SPACED 12" ON CENTER. MOUNT MULTI -OUTLET ASSEMBLY ON TOP RAIL OF GONDOLA. PROVIDE FENDER WASHER SPACERS UNDERNEATH MULTI -OUTLET ASSEMBLY SO RACEWAY IS INSTALLED LEVEL ON TOP RAIL OF GONDOLA. INSTALL MULTI -OUTLET ASSEMBLY KIT THE ENTIRE LENGTH OF THE GONDOLA RUN, STOPPING A MINIMUM OF 12" FROM EACH END OF THE GONDOLA RUN. INSTALL MULTI -OUTLET ASSEMBLY KIT PER MANUFACTURER'S REQUIREMENTS. REFER TO 9/E541. 501 INSTALL POWER AND DATA FOR OWNER FURNISHED PROJECTOR GEAR ENCLOSURE PER MANUFACTURERS REQUIREMENTS. PROJECTOR TO BE LOCATED 17-2" FROM WALL. 502 PROVIDE RECEPTACLE WITH 6' RELOC WHIP CORD LOOSE IN BASE DECK OF GONDOLA. COIL UP RELOC CORD FOR FUTURE USE. 588 RELOCATE PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. 898 PROVIDE CAST IRON FLOOR BOX WITH FLUSH SERVICE THAT CAN BE USED IN CARPET OR TILE. SPECIFICATION: THOMAS & BETTS STEEL CITY FLOOR BOX 600SC WITH BRASS CARPET FLANGE P6OCP AND BRASS MOPETITE COVERPLATE P6ODS OR EQUAL. ELII __ 66 9i1 REVIEWED FOR CO�FP�70C��CTH DEC 13 2011 City of Tukwila BUILDING DIVIWIN, RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL EXPIRES .l8, -r CO CO rn Q Z W Y W 0--I = m D o O Q cf) Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JM Checked By JS/TK BEAUTY BLOWOUT POWER & SYSTEMS PLAN E385 11/17/2017 3:49:07 PM Refrigeration Cooler Schedule SYST # REFRIGERATION CASES LIGHTING FANS & ANIT-SWEAT FRAME HEATERS NOTES MODEL USE kVA PANEL CIRCUIT kVA PANEL CIRCUIT B01 6' OPEN CASE REFRIG 0.23 kVA LP -12B 9 0.06 kVA LP -12B 2 1 B02 8' OPEN CASE REFRIG 0.23 kVA LP -12B 11 0.06 kVA LP -12B 4 1 B02 12' OPEN CASE REFRIG 0.42 kVA LP -12B 11 0.11 kVA LP -12B 4 1 B02 12' OPEN CASE REFRIG 0.42 kVA LP -12B 11 0.11 kVA LP -12B 4 1 B03 12' OPEN CASE REFRIG 0.42 kVA LP -12B 9 0.11 kVA LP -12B 2 1 B04 12' OPEN CASE REFRIG 0.24 kVA LP -12B 13 0.14 kVA LP -12B 6 1 B10 3 DOORS REFRIG 0.1 kVA LP -12B 17 0.43 kVA LP -12B 12 2 B10 5 DOORS REFRIG 0.16 kVA LP -12B 17 0.7 kVA LP -12B 12 2 B10 4 DOORS REFRIG 0.12 kVA LP -12B 17 0.53 kVA LP -12B 12 2 F01 6' OPEN CASE REFRIG 0.11 kVA LP -12B 36 0.1 kVA LP -12A 6 1 F02 8' OPEN CASE REFRIG 0.16 kVA LP -12B 36 0.1 kVA LP -12A 8 1 F03 8' OPEN CASE REFRIG 0.16 kVA LP -12B 36 0.1 kVA LP -12A 10 1 F04 6' OPEN CASE REFRIG 0.11 kVA LP -12B 36 0.1 kVA LP -12A 12 1 F05 8' OPEN CASE REFRIG 0.16 kVA LP -12B 36 0.1 kVA LP -12A 14 1 F06 8' OPEN CASE REFRIG 0.16 kVA LP -12B 36 0.1 kVA LP -12A 16 1 F07 6' OPEN CASE REFRIG 0.11 kVA LP -12B 38 0.1 kVA LP -12A 18 1 F08 8' OPEN CASE REFRIG 0.16 kVA LP -12B 38 0.1 kVA LP -12A 20 1 F09 8' OPEN CASE REFRIG 0.16 kVA LP -12B 38 0.1 kVA LP -12A 22 1 F10 6' OPEN CASE REFRIG 0.11 kVA LP -12B 38 0.1 kVA LP -12A 24 1 F11 8' OPEN CASE REFRIG 0.16 kVA LP -12B 38 0.1 kVA LP -12A 26 1 F12 8' OPEN CASE REFRIG 0.16 kVA LP -12B 38 0.1 kVA LP -12A 28 1 REFRIGERATION COOLER SCHEDULE NOTES: 1. CIRCUITS ARE 120V, 1 PHASE, 2#10, #10 GROUND MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. 2. HOMERUN CIRCUIT TO BE 2#6, #10 GROUND. Refrigeration Freezer Schedule SYST # MANUFACTURER REFRIGERATION CASES LIGHTING FANS & ANTI SWEAT HEATERS(FRAMES) ANTI SWEAT HEATERS (CASE DOORS) NOTES MODEL USE kVA PANEL CIRCUIT kVA PANEL CIRCUIT AMPS PANEL CIRCUIT AO1A HILL PHOENIX 8' ISLAND - OWIZ FROZEN 0 kVA PROVIDE 1"C IN CHASE FOR LV CABLE. PROVIDE CONDUIT FROM ACCESSIBLE CEILING SPACE TO STUB -OUT AT 88". INSTALL CABLES TO TOP OF CASES. REFER TO SHEET R621 FOR REMS CABLES AND ROUTING. 0.42 kVA LP -12B 23 0 A COORDINATE VERTICAL PIPE DROPS OF PLUMBING, REFRIGERATION AND ELECTRICAL CONDUIT. ALL PIPING AND CONDUIT SHALL BE BUNDLED TIGHTLY TOGETHER TO MINIMIZE THE SIZE OF THE FALSE COLUMN PIPE ENCLOSURE. VERTICAL PIPE DROP LOCATION SHALL CORRESPOND WITH LOCATION OF FALSE COLUMN SHOWN ON ARCHITECTURAL PLANS. MAXIMUM FALSE COLUMN ENCLOSURE DIMENSIONS SHALL BE 14" X 14". REFER TO ARCHITECTURAL FALSE COLUMN ENCLOSURE DETAIL. 1 AO1B HILL PHOENIX 8' ISLAND - OWIZ FROZEN 0 kVA 0.42 kVA LP -12B 23 0 A 1 AO1C HILL PHOENIX END CAP - OWEZ DUAL TEMP 0 kVA 0.24 kVA LP -12B 23 0 A 1 A08 HUSSMANN 3 DOORS FROZEN 0.1 kVA LP -12B 7 0.48 kVA LP -12B 39 2.3 A LP -12B 28 1 A09 HUSSMANN 4 DOORS FROZEN 0.12 kVA LP -12B 7 0.62 kVA LP -12B 41 3.1 A LP -12B 30 1 REFRIGERATION FREEZER SCHEDULE NOTES: 1. CIRCUITS ARE 120V, 1 PHASE, 2#10, #10 GROUND MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. B04 05M-12 MARKET AREA POWER & SYSTEMS PLAN ,,401 SCALE: 1/4" = 1'-0" ELI1 DTI REVIEWED FOE COMPLIANCE WITh NFPA 70 o NPS' fir• DEC 13 2fll7 City of .Tukwila BUILDING DIVI.� RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 GUSH ING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JDP Checked By JS/TK MARKET AREA POWER & SYSTEMS PLAN E401 11/17/2017 3:49:11 PM REFR GENERAL NOTES A. B. C. D. INSTALL LOW VOLTAGE CABLE FROM REFRIGERATION CONTROL PANELS TO ROOFTOP CONDENSING UNIT, WALK-IN COOLERS AND FREEZERS, ALARM PANEL IN GUEST SERVICES, REMS L/DH CONTROL CABINET AND EACH SALES FLOOR REFRIG CASE. CABLE FURNISHED BY REMS VENDOR. FINAL CONNECTIONS BY REMS CONTRACTOR. REFER TO SHEET R621 FOR REMS WIRING DETAILS. INSTALL LOW VOLTAGE CABLE TO THE CONNECTION POINT AT TOP OF EACH SALES FLOOR CASE. DO NOT TURN ON ELECTRICAL POWER TO THE LIGHTS AND THE FRAME & DOOR HEATERS UNTIL THE REFRIGERATION HAS BEEN TURNED ON. ROUTE CASE LIGHTS THROUGH REMS LIGHTING CONTROL CABINET. GENERAL NOTES A. B. C. D. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. CONDUIT IN UNFINISHED SPACES TO BE EXPOSED. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. PROVIDE JUNCTION BOXES FOR FIRE ALARM, SPRINKLER SUPERVISORY AND INTRUSION DEVICES. COORDINATE ROUGH -IN LOCATION WITH E900 SERIES DRAWINGS. BOXES FOR CEILING MOUNTED NOTIFICATION DEVICES SHALL BE FOUR SQUARE, DEEP, WITH MUDRING. KEYNOTES # DESCRIPTION 757 PROVIDE J -BOX AT 86" AFF. PROVIDE 1"C FROM J -BOX TO STUB -OUT AT 2" AFF. PROVIDE FLEXIBLE CONDUIT FROM STUB TO CASE WIREWAY. PROVIDE FINAL CASE CONNECTIONS FOR POWER WIRING. 758 PROVIDE 1"C HOMERUN FOR POWER WIRING. CONCEAL IN WALL TO ABOVE THE CEILING. REFER TO THE REFRIGERATION EQUIPMENT SCHEDULE FOR CIRCUIT REQUIREMENTS FOR EACH CASE.' 760 PROVIDE 1 1/4°C HOMERUN FOR POWER WIRING. REFER TO THE REFRIGERATION EQUIPMENT SCHEDULE FOR CIRCUIT REQUIREMENTS. 761 PROVIDE 1"C IN CHASE FOR LV CABLE. PROVIDE CONDUIT FROM ACCESSIBLE CEILING SPACE TO STUB -OUT AT 88". INSTALL CABLES TO TOP OF CASES. REFER TO SHEET R621 FOR REMS CABLES AND ROUTING. 762 ROUTE CONDUIT FROM ACCESSIBLE CEILING SPACE DOWN THROUGH CHASE. PROVIDE FLEXIBLE CONNECTION TO CASE WIREWAY FOR CASE LOADS. REFER TO SHEET A111 FOR EXACT LOCATION OF FALSE COLUMN CHASE. 763 COORDINATE VERTICAL PIPE DROPS OF PLUMBING, REFRIGERATION AND ELECTRICAL CONDUIT. ALL PIPING AND CONDUIT SHALL BE BUNDLED TIGHTLY TOGETHER TO MINIMIZE THE SIZE OF THE FALSE COLUMN PIPE ENCLOSURE. VERTICAL PIPE DROP LOCATION SHALL CORRESPOND WITH LOCATION OF FALSE COLUMN SHOWN ON ARCHITECTURAL PLANS. MAXIMUM FALSE COLUMN ENCLOSURE DIMENSIONS SHALL BE 14" X 14". REFER TO ARCHITECTURAL FALSE COLUMN ENCLOSURE DETAIL. 780 PROVIDE 1"C FOR LV CABLE. PROVIDE CONDUIT FROM ACCESSIBLE CEILING SPACE TO STUB -OUT AT 88". INSTALL CABLES TO TOP OF CASES. REFER TO SHEET R621 FOR REMS CABLES AND ROUTING. 795 UTILIZE EXISTING 1 1/4"C FEEDING REFRIGERATION CASE FOR NEW POWER WIRING. REFER TO THE REFRIGERATION EQUIPMENT SCHEDULE ON SHEET E601 FOR CIRCUIT REQUIREMENTS FOR NEW CASE. UTILIZE AND EXTEND EXISTING CIRCUITS AS REQUIRED. ELI1 DTI REVIEWED FOE COMPLIANCE WITh NFPA 70 o NPS' fir• DEC 13 2fll7 City of .Tukwila BUILDING DIVI.� RECEIVED CITY OF TUKWILA NOV 2 1 2017 PERMIT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 GUSH ING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA 301 STRANDER BLVD TUKWILA, WA 98188 Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JDP Checked By JS/TK MARKET AREA POWER & SYSTEMS PLAN E401 11/17/2017 3:49:11 PM NOTES: A. INSTALL BATTERY ELIMINATOR TRANSFORMER (FURNISHED UNDER SECTION 08 7100). PROVIDE 120 VOLT BRANCH CIRCUIT TO TRANSFORMER AND LOW VOLTAGE BATTERY ELIMINATOR. B. ROUTE CONDUCTORS TO LOW VOLTAGE TERMINALS OF BATTERY ELIMINATOR THROUGH CONCEALED 112°C C. ROUTE CONDUCTORS TO DETEX HARDWARE THROUGH RACEWAY. PROVIDE FINAL CONNECTION TO DETEX HARDWARE. D. PAINT ALL EXPOSED RACEWAY TO MATCH SURFACE ON WHICH IT IS MOUNTED BRANCH CIRCUIT WIRING 12 VAC, 25 VA TRANSFORMER LOW VOLTAGE WIRING IN CONDUIT CONCEAL IN WALL FURRING. — o V t. 1 EMERGENCY EXIT DOOR (DETEX) E511 SCALE: NOT TO SCALE 1/4" HOLE AND GROMMET 7 CEILING U.N.O. SECURITY CONTACT CONDUIT FLUSH MOUNT J -BOX FOR BATTERY ELIMINATOR (BE -961-1) SURFACE RACEWAY, WIREMOLD V500 SERIES OR EQUIVALENT W/ 90° FLAT ELBOW CORNER. RUN AS CLOSE TO HINGES AS POSSIBLE. CONNECT TO J -BOX W/ WIREMOLD V500 SERIES 18" LONG FLEXIBLE SECTION. COLUMN TEMPERATURE / HUMIDITY SENSOR DETAIL STEEL COLUMN REFER TO SHEET E701 FOR WIRING DIAGRAM TEMPERATURE/ HUMIDITY SENSOR E51 1j SCALE: NOT TO SCALE ea SECURE THREADED ROD WITH SELF HOLDING CHANNEL NUT, SIZE AS REQUIRED CONTINUOUS THREADED ROD -3/8"0 MINIMUM, SIZE AS REQUIRED DO NOT SUPPORT CONDUIT FROM WEB OF JOIST MAXIMUM OF 1" CONDUIT(S) ARE 12\ HANGER LOAD SUPPORT SECTION ALLOWED TO BE ATTACHED TO JOIST BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS E511 / SCALE: NOT TO SCALE MINIMUM 4" CLEAR FROM BOTTOM OF ROOF DECK TO TOP OF CABLE FIRE ALARM, INSTRUSION, PAGING, EMS, COAX & CONTROL CABLES MAY BE SUPPORTED ON JOIST FLANGE OR TOP OF BOTTOM CHORD (REFER TO GENERAL NOTES) GENERAL NOTES: A. REFER TO DETAIL 9/E511 OR 8/E941 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. B. MINIMUM OF 3" SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8 & 800.24 - MECHANICAL EXECUTION OF WORK. D. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. PROVIDE BUSHING CEILING ROUTE CONDUIT INTO HOLLOW METAL DOOR FRAME 6" FROM DOOR JAMB, LATCH SIDE OF DOOR SECURI 'EVICESAND CABL 2 SECTION INTERIOR DOOR SECURITY DEVICE E511 SCALE: NOT TO SCALE 8\ DOCK DOOR ELEVATION EXTERIOR WALL DOOR HEADER `� /,' \o \ \o / \ \\ '/// UB CONDUIT OUT OF EXTERIOR \ � �� // WALL. PROVIDE BUSIN / \ • // / / BRANCH CIRCUIT WIRING ` k \\ / ` \o /,i / I t 12 VAC, 25A TRANSFORMER CEILING SECURITY DOOR CONTACT, REFER TO DETAIL 2/E982 DOOR FRAME INTERIOR WALL J -BOX PRE-INSTALLED IN DOOR HEADER FOR SECURITY CONTACT FLUSH MOUNTED J -BOX FOR BATTERY ELIMINATOR (BE -96191) PROVIDE 3/8" ARMORED CABLE FROM BATTERY ELIMINATOR J -BOX TO SURFACE MOUNTED RACEWAY MOUNTED ON DOOR PROVIDE GROMMET WHEN ARMORED CABLE EXIT WALL CAVITY PROVIDE 6" ARMORED CABLE SERVICE LOOP VERTICAL MOUNTED RACEWAY SECTION EXTERIOR DOOR SECURITY DEVICE SCALE: NOT TO SCALE E511 / SCALE: 1/4" = 1'-0" E511 SECURE CHANNEL AT EACH END TO TOP CHORD OF BAR JOIST AT PANEL POINT W/CHANNEL CLIP AND SET SCREW DO NOT SUPPORT CONDUIT FROM WEB OF JOIST 1-1/2" X 1-1/2" X 12 GA STEEL CHANNEL WITH 1/2" DIA. BOLT HOLES ON 1-1/2" CENTERS CHANNEL PIPE STRAP SIZE AS REQUIRED NOTES: A. MOUNT TRAPEZE ASSEMBLY AS HIGH AS POSSIBLE, BUT MAINTAIN MIN 2" BELOW ROOF DECK. DO NOT INTERFERE W/ WORK OF OTHER TRADES, BLOCK AIR DISTRIBUTION, FIRE PROTECTION OUTLETS OR LIGHT FIXTURES. B. HANG FROM TOP CHORD PANEL POINT OF BAR JOIST. DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST C. MAXIMUM OF 1" CONDUIT(S) ARE ALLOWED TO BE ATTACHED TO JOIST BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. 13 HANGING LOAD SUPPORT DETAIL E511 SCALE: NOT TO SCALE CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM TOP CHORD OF JOIST (DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST) DO NOT SUPPORT CABLES FROM WEB OF JOIST CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM BOTTOM CHORD OF JOIST (REFER TO GENERAL NOTES) ONLY VOICE, DATA, BACKBONE & CCTV CABLES E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE. CABLE SHALL BE INSTALLED IN A MANNER THAT NORMAL BUILDING MOVEMENT WILL NOT DAMAGE CABLES. LOW VOLTAGE CABLE SUPPPORT LOCATION DETAIL - PARALLEL SCALE: NOT TO SCALE T / • LIQUIDTIGHT COUPLING IMC 21 LIQUID TIGHT • IMC • PIPE BOX L 0 J l MULTI CONDUCTOR TYPE MC CABLE. II II II II 0000000000000 � STANDARD STRUT CHANNEL WITH TYPE MC SADDLE CLAMP. U? TO STRUCTURE WITHLILANK COVERPLATE ORO LL3 _„..'OLEIC ,EX, ; R`:;RynLL FOR '..OND'.; i CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM TOP CHORD OF JOIST (DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST) (10)1” CONDUIT OR 1" DIA TYPE MC CABLES CONDUIT(S) & CABLE(S) ARE J r4 1 0 N CONDUIT @ STOREFRONT DETAIL E511 / SCALE: NOT TO SCALE ALLOWED TO BE ATTACHED TO BOTTOM CHORD OF JOIST (REFER TO LOAD REQUIREMENTS) (2) BUNDLES OF 50 JOIST SPAN. ROUTE FLEX CONDUIT THRU 2" COPE IN BEAM REFER TO 7A/S531 ROUTE FLEX CONDUIT(S) DOWN VERTICAL MULLION LOCATED IN CENTER OF DOORS. REFER TO STORE FRONT MANUFACTUERS DETAIL 1/6.05 SECURITY DEVICES (TYP) REFER TO CCTV CAMERA DOOR OPERATOR LOW VOLTAGE CABLES MINIMUM 4" CLEAR FROM BOTTOM OF ROOF DECK TO TOP OF CABLES //, /// \. //, I\\S' '/, I GENERAL NOTES: A. MAXIMUM OF 100 LBS TOTAL LOAD OF EQUIPMENT IS ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM CHORD. WHEN LOAD REQUIREMENTS LISTED BELOW ARE ATTAINED, ATTACH ADDITIONAL CONDUIT(S) AND CABLE(S) TO JOIST TOP CHORD. B. LOAD REQUIREMENTS: MAXIMUM OF (10) 1" CONDUITS OR MAXIMUM OF (10)1" DIA TYPE MC CABLES ARE ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM CHORD AND MAXIMUM OF (2) BUNDLES OF LOW VOLTAGE CABLES ARE ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM CHORD AND MAXIMUM OF (20) SINGLE LOW VOLTAGE CABLES ARE ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM CHORD C. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. D. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE. CBLE SHALL BE INSTALLED IN A MANNER THAT NORMAL BUILDING MOVEMENT WILL NOT DAMAGE CABLES. 9 LOW VOLTAGE SUPPORT REQUIREMENTS E511 SCALE: NOT TO SCALE 114 N E IOR WALL JTY N UP TO STRUCTURE .1L' _B DRILL 3'• HOLE IN EXTERIOR Y' -ALL FOR CO,, '/IT TEMPERATURE SENSOR ..Iti ID SENSOR EXTERIOR WA_ LL OSED TEMP,. TEMP SENSOR (OAP) MOUNTING DETAIL \511 / SCALE: NOT TO SCALE SECURE CHANNEL AT EACH END TO TOP CHORD OF BAR JOIST AT PANEL POINT WITH CHANNEL CLIP & SET SCREW. TYPICAL. DO NOT SUPPORT TYPE MC CABLES FROM WEB OF JOIST MOUNT TYPE MC CABLE ASSEMBLY AS HIGH AS POSSIBLE. MAINTAIN MIN 4" BELOW ROOF DECK. DO NOT INTERFERE W/ WORK OF OTHER TRADES, BLOCK AIR DISTRIBUTION, FIRE PROTECTION OUTLETS OR LIGHT FIXTURES. TYPE MC CABLES CAN BE SUPPORTED ON JOIST FLANGE OR TOP OF BOTTOM CHORD (REFER TO GENERAL NOTES) TYPE MC CABLES ALLOWED TO BE SUPPORTED FROM BOTTOM CHORD OF JOIST (REFER TO GENERAL NOTES) GENERAL NOTES: A. TYPE MC CABLE ASSEMBLY SUPPORT IS REQUIRED FOR MC CABLE EXITING EDC AND ENTERING SALES FLOOR. B. MAXIMUM OF 1" DIA TYPE MC CABLE(S) ARE ALLOWED TO BE ATTACHED TO JOIST SPAN BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. C. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. TYPE MC CABLE SUPPORT DETAIL PARALLEL & PERPENDICULAR \51� SCALE: NOT TO SCALE CONDENSING UNIT CONDENSING UNIT TYPICAL CONDUIT DIAGRAM SIDEVIEW LIQUID TIGHT IF CONDUIT LENGTH BETWEEN CU & PIPING BOX IS LESS THEN 6-0", THEN LIQUID TIGHT IS ACCEPTABLE, OTHERWISE USE MC LIQUID TIGHT E511 SCALE: NOT TO SCALE PROVIDE METALLIC 24! X24 6" DEEP PULL BOX WITH SCREW VVPr+,;.,...n tJ E:\ MODULEEAS INSTALLED IN PULL BOX BY EAS VENDOR MOUNT PULL BOX ,: ABOVE ACCESSIBLE CEILING LAY -IN CEILING EAS _____.._ PEDESTALS PROVIDED BY EAS VENDOR EAS -W/ �<{��w€iT • BY GENERAL CONTRACTOR FLOOR EAS POWER & SYSTEMS DETAIL SCALE: NOT TO SCALE / 0 UU 0 314" CONDUIT STUBBED FROM BOX TO BOTTOM SIDE r '.'`i.i _.. 4 1 i.:iY..73vC O'" JOIST FOR DATA CABLE CONNECTION PROVIDE QUADRI IPi E RECEPTACLE INSIDE PULI BOX. REC L, EPi.'91.0E THE -' IN UPPER RIGHT HAND CORNER OF THE PULL BOX,:OICE/_ATA CONTRACTOR TO PROVIDE DATA OUTLET BELOW RECEPTACLE. PROVIDE 1 .. . CONDUIT � AND 's `r' ....^CEI PULL BOX ?'ei4 D :;-BOX MOUNTED .AT EASE Oh WALL PROVIDE .-BOX AT BASE OF WALL ABOVE S.A` OUT. VERIFY LOCATION WITH€ GENERAL CONTRACTOR. OR. SECURE CHANNEL AT EACH END TO TOP CHORD OF BAR JOIST AT PANEL POINT WITH CHANNEL CLIP & SET SCREW. TYPICAL. BAR JOIST 1-1/2" X 1-1/2" X 12 GA STEEL CHANNEL WITH 1/2" HOLES ON 1-1/2" CENTERS ATTACH THREADED RODS TO CHANNEL W/ SELF HOLDING CHANNEL NUTS AND DOUBLE NUTS AND WASHERS BAR JOIST CONDUITS 10 CONDUIT HANGER DETAIL (PLAN VIEW) E511 SCALE: NOT TO SCALE CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM TOP CHORD OF JOIST (DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST) DO NOT SUPPORT CABLES FROM WEB OF JOIST FIRE ALARM, INSTRUSION, PAGING, EMS, COAX & CONTROL CABLES CAN BE INSTALLED ON JOIST FLANGE OR TOP OF BOTTOM CHORD (REFER TO GENERAL NOTES) CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM BOTTOM CHORD OF JOIST (REFER TO GENERAL NOTES) VOICE, DATA, BACKBONE & CCTV CABLES GENERAL NOTES: A. REFER TO DETAIL 9/E511 OR 8/E941 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. B. MINIMUM OF 3" SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8 & 800.24 - MECHANICAL EXECUTION OF WORK. D. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE. CABLE SHALL BE INSTALLED IN A MANNER THAT NORMAL BUILDING MOVEMENT WILL NOT DAMAGE CABLES. /15 LOW VOLTAGE CABLE SUPPORT LOCATION DETAIL - PARALLEL PERPENDICULAR \511 SCALE: NOT TO SCALE /' 6'-0" 6'-0" PROVIDE SUPPORT 6-0" OC GENERAL NOTES: A. TYPE MC CABLE ASSEMBLY SUPPORT IS REQUIRED FOR MC CABLE EXITING FLOOR. B. MAXIMUM OF 1" DIA TYPE MC CABLE(S) ARE ALLOWED TO BE ATTACHED TO SECURE CHANNEL AT EACH END TO TOP CHORD OF BAR JOIST AT PANEL POINT WITH CHANNEL CLIP & SET SCREW. TYPICAL. MOUNT TYPE MC CABLE ASSEMBLY AS HIGH AS POSSIBLE. MAINTAIN MIN 4" BELOW ROOF DECK. DO NOT INTERFERE W/ WORK OF OTHER TRADES, BLOCK AIR DISTRIBUTION, FIRE PROTECTION OUTLETS OR LIGHT FIXTURES. MULTI CONDUCTOR TYPE MC CABLE DO NOT SUPPORT TYPE MC CABLES FROM WEB OF JOIST STANDARD STRUT CHANNEL WITH TYPE MC SADDLE CLAMP TYPE MC CABLES ARE ALLOWED TO BE SUPPORTED FROM BOTTOM CHORD OF JOIST (REFER TO GENERAL NOTES) EDC AND ENTERING SALES JOIST SPAN BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. C. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. TYPE MC CABLE SUPPORT DETAIL 19 \ PARALLEL JOIST E! 511 j SCALE: NOT TO SCALE FIRE ALARM MANUAL PULL STATION REFRIG ANNUNCIATOR (AT GUEST SERVICE ONLY) SECURITY SYSTEMS ANNUNCIATOR (AT GUEST SERVICE ONLY) FLOOR FIRE ALARM ANNUNCIATOR PROVIDE 3 -GANG DEEP JUNCTION BOX (22� Guest Service Annunciator Panel Elevation SCALE: 1/4" = CENTER LINE OF MOUNTING BRACKET, POWER & SYSTEMS JOIST SPAN CEILING z z Zfo NOTE: VERIFY LOCATIONS OF ALL COLUMN MOUNTED DEVICES WITH OWNERS SITE REPRESENTATIVE TO AVOID ANY ACCESSIBILITY CONFLICTS. MAXIMUM ALLOWABLE HOLE SIZE TO BE 1". DRILL & INSTALL GROMMET & FD CAST JUNCTION BOX FOR FIRE ALARM REMOTE TEST STATION ON COLUMNS REFER TO E911 6 \ COLUMN OUTLET DETAIL DRILL & INSTALL 4" X 4" J -BOX FOR NETWORK/DATA CABLES 4" X 4" J -BOX DRILL & INSTALL 4" X 4" J -BOX FOR THERMOSTAT WIRING 1/2" FLEXIBLE CONDUIT HOLLOW SQ STEEL COLUMN DRILL & INSTALL GROMM FOR RTU TEMP SENSOR ON COLUMNS . LOCATIONS SHOWN ON MECHANICAL DRAWINGS. REFER T SHALLOW CAST ALUM FS BOX W/STAINLESS STEEL COVER - PLATE FOR NEMA 5 -20R -GRAY RECEPTACLE OR DATA OUTLET FLOOR E511 1 SCALE: NOT TO SCALE DO NOT SUPPORT CONDUIT FROM WEB OF JOIST 0 rI ucg' CHANNEL PIPE STRAP SIZE AS REQUIRED MAXIMUM OF 1" CONDUIT(S) ARE ALLOWED TO BE ATTACHED TO JOIST BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. NOTES: A. MOUNT ASSEMBLY AS HIGH AS POSSIBLE, BUT MAINTAIN MIN 4" BELOW ROOF DECK. DO NOT INTERFERE W/ WORK OF OTHER TRADES, BLOCK AIR DIST, FIRE PROTECTION OUTLETS OR LIGHT FITURES. B. DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST CONDUIT HANGER SECTION \51 1.y SCALE: NOT TO SCALE CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM TOP CHORD OF JOIST (DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST) GENERAL NOTES: A. REFER TO DETAIL 9/E511 OR 8/E941 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. B. MINIMUM OF 3" SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8 & 800.24 - MECHANICAL EXECUTION OF WORK. D. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE. CABLE SHALL BE INSTALLED IN A MANNER THAT NORMAL BUILDING MOVEMENT WILL NOT DAMAGE CABLES. DO NOT SUPPORT CABLES FROM WEB OF JOIST CABLE(S) ARE ALLOWED TO BE SUPPORTED FROM BOTTOM CHORD OF JOIST (REFER TO GENERAL NOTES) VOICE, DATA, BACKBONE & CCTV CABLES FIRE ALARM, INSTRUSION, PAGING, EMS, COAX & CONTROL CABLES MAY BE SUPPORTED ON JOIST FLANGE OR TOP OF BOTTOM CHORD (REFER TO GENERAL NOTES) LOW VOLTAGE CABLE SUPPPORT LOCATION DETAIL - PERPENDICULAR 511 SCALE: NOT TO SCALE NOTES: A. INSTALL BATTERY ELIMINATOR TRANSFORMER (FURNISHED UNDER SECTION 08 7100). PROVIDE 120 VOLT BRANCH CIRCUIT TO TRANSFORMER AND LOW VOLTAGE BATTERY ELIMINATOR. B. ROUTE CONDUCTORS TO LOW VOLTAGE TERMINALS OF BATTERY ELIMINATOR THROUGH CONCEALED 1/2"C C. ROUTE CONDUCTORS TO DETEX HARDWARE THROUGH RACEWAY. PROVIDE FINAL CONNECTION TO DETEX HARDWARE. BRANCH CIRCUIT WIRING 12 VAC, 25 VA TRANSFORMER CEILING U.N.O. LOW VOLTAGE WIRING IN CONDUIT CONCEAL IN WALL FURRING FLUSH MOUNTED J- BOX FOR BATTERY ELIMINATOR (BE -96191) LOW VOLTAGE WIRING IN CONDUIT CONCEAL IN WALL FURRING ROUTE CONDUIT TO POWER DOOR HINGE E STUB CONDUIT OUT OF EXTERIOR WALL. PROVIDE BUSHING. co Tvzo CD z J w U 0 / / / / / / n / PROVIDE 1/2"C FOR SECURITY DOOR CONTACT J -BOX PRE-INSTALLED IN DOOR HEADER FOR SECURITY CONTACT SECURITY DOOR CONTACT, REFER TO DETAIL 2/E982 STOREFRONT GLASS DOOR EMERGENCY EXIT DOOR (DETEX) FOR GLASS DOORS AT STOREFRONT E.._5=1;y1 SCALE: NOT TO SCALE 23 TRAINING/LOUNGE TV ELEVATION DETAIL E511 SCALE: NOT TO SCALE E L11 COMPLIANCE W1.7"' NFPA 70 - NPC DEC 1 g 71117 City of Tukwila BUILDING DIVISr“, RECEIVED CITY OF TUKWILA - NOV 2 1 2017 PERMIT TARGET. 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO F- 0 CO LLI F— Project Number T-0627 Version:V13A Drawn By RS Checked By JLS ELECTRICAL DETAILS E511 11/17/2017 3:49:15 PM 1 FLOOR OUTLET TYPE 'A' & 'B' 4" X 4" X 2 1/8" JUNCTION BOX WITH COVERPLATE (TYPICAL) 1 3/8", IN LENGTH, RIGID GALV STEEL CHASE NIPPLE STUB (TYP) ANCHOR JUNCTION BOX TO FLOOR WITH CONCRETE ANCHORS (TYP) FLEXIBLE CONDUIT TO EQUIPMENT OR RECEPTACLE PROVIDE SHIM AS REQUIRED RIGID GALV STEEL COUPLING EXTEND COUPLING 1/2" AFF CONDUIT AS REQUIRED PVC COATED RIGID GALV STEEL CONDUIT (TYP) ADDITIONAL CONDUIT (IF REQUIRED) E521 i SCALE: NOT TO SCALE NOTES: DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS OR CONDUITS COOLER / FREEZER CONDUIT PENETRATION DETAIL SCALE: NOT TO SCALE JUNCTION BOX VERTICAL SEALING FITTING AFTER WIRING WORK IS COMPLETE FILL SEALING FITTING WITH SILICONE CAULK. REFER TO SPEC SECTION 07 9200. INSULATION BY REFR. CONTRACTOR. REFER TO 11/R501. CAULK PENETRATION BOTH SIDES OF PANEL W/ SILICONE CAULK REFER TO SPEC SECTION 07 9200 INSULATED PANEL CEILING DRILL HOLES NO MORE THAN 1/8" BIGGER THAN CONDUIT SIZE RIGID CONDUIT / 13 \ SUPPLY WIRING TO LED ARC \521 SCALE: NOT TO SCALE GHT GUIDE PT OT'l r -.f ...M... , .RES BEHIND D LGM, . ENGINE TO 'BEI SEEN LED GU:GE AND _. I,',' _....,.N__ CLEAR yiR P` L.":THREADED BUSHING ING > 1'I CAP S ROUTED THROUGH Y I' ..O LED DRV, 1: POWER SUPP.^I Y NOT USED SCALE: NOT TO SCALE LIQUIDTIGHT FLEXIBLE CONDUIT TO EQUIPMENT OR RECEPTACLE RIGID GALV STEEL CONDUIT STUB (TYP) RIGID GALV STEEL COUPLING FLUSH WITH FLOOR (TYP) PVC COATED RIGID GALV STEEL CONDUIT (TYP) CONDUIT AS REQUIRED TYPE FD BOX WITH WEATHER- PROOF COVERPLATE AND DEVICE LIQUIDTIGHT FLEXIBLE CONDUIT TO EQUIPMENT OR RECEPTACLE RIGID GALV STEEL CONDUIT STUB (TYP) RIGID GALV STEEL COUPLING FLUSH WITH FLOOR (TYP) PVC COATED RIGID GALV STEEL CONDUIT (TYP) CONDUIT STUBS AND DEVICE BOX SCALE: NOT TO SCALE PROVIDE CONDUITS FOR LOW VOLTAGE (FA & EMS) CABLES. EXTEND CONDUITS A MINIMUM OF 18" ABOVE THE BOTTOM OF THE CONTROL CABINET. BUSH & SUPPORT CONDUITS. ROUTE FEEDER CONDUIT TO J -BOX ENCLOSING THE UNIT DISCONNECT (CIRCUIT BREAKER). PROVIDE GROUND WIRE TO J -BOX. ALL CONNECTIONS SHALL BE LIQUID TIGHT. USE KNOCKOUTS PROVIDED. NO OTHER PENETRATIONS ALLOWED. SEAL ALL UNUSED OPENINGS WITH EPCO DUCTSEAL COMPOUND. LIQUIDTIGHT FITTING LIQUIDTIGHT CONDUIT 3 RTU WIRING MC FITTING COUPLING LIQUID TIGHT FITTING DETAIL E521 / SCALE: NOT TO SCALE 1" LIQUIDTIGHT FLEX CONDUIT AND FITTINGS WITH SERVICE LOOP ROOF FLASHING AND MEMBRANE REFER TO 2/A142 1" CONDUIT INTERIOR JUNCTION BOX EXTERIOR BUILDING SIGN. VERIFY — LOCATION AND REQUIREMENTS W/ SIGN VENDOR AND GC. PARAPET PROVIDE 3/4" IMC FOR PARAPET PENETRATION REFER TO 6/A142 PROVIDE WP CONDULET FOR EACH PARAPET PENETRATION. PROVIDE 3/4" IMC BETWEEN CONDULETS (TYP) ROOF DECK A EXTERIOR CCTV MOUNTING DETAIL SCALE: NOT TO SCALE RECEPTACLE PARAPET MOUNTED CCTV CAMERA. REFER TO 5/A144 TOP OF PARAPET WEATHERPROOF EXTERIOR JUNCTION BOX. TOP OF BOX MINIMUM 1" BELOW TOP OF PARAPET. FILL ANCHOR HOLES WITH SEALANT RECOMMENDED BY ROOF MANUFACTURER. EXTERIOR WALL SATED I GR`, DED By L>c.. : PROVIDE GROUND BUS ..... MOUNT ON COI LIMN. COAX CABLE PROVID BY SATELLITE VENDOR E9 COAX CARI FtC:Jl.. .4 By OW VOLTAGE CONTRACTOR Ti SATELLITE RECEIVER i OC TED IN CONTROL ROOM • PROVIDE WP „MO ION _ ny. INSTALL ON COLUMN _r POWER CORD FOR DE-ICIN SATELLITE E VENDOR (ONLY REQUIRED IN COLD AND FREEZING RAIN CLIMATE,S5 PROVIDE G RECEPTACLE , WP "WHILE USE COVERPLATE .... ROOF 4 SATELLITE DISH POWER & SYSTEMS DETAIL E521 / SCALE: NOT TO SCALE EPOS/CPU FOUR EX RECEPTACLE COMBINATION VOICE/DATAOUTLET MULTI -OUTLET ASSEMBLY COM VOICE/DATA ONTI ET • FOURPLEX RECEPTACLE ..... • • \\• • • • ; • \ \ \•\ \ \ \•• • NOTE: E: INSTALL OUTLETS FOR POWER SYSTEMS INSIDE OF FIXTUREAS 7 SHOWN. ROUTE CONDUIT(S) THRU BASE DECK OF FIXTURE OVER TO ACCESS PANEL(S) AND ALONG INSIDE OF THE BACK PANEL OF CABINET. SCREWS FOR INSTALLING DEVICES IN CABINET FIXTURE NOT 'OEXCEED 1.//2"IN W TI:....... • LED DRIVER E521 % SCALE: NOT TO SCALE LED DRIVER BOX LOCATED ABOVE ACCESSIBLE CEILING PARAPET PENETRATION REFER TO 6/A142 PROVIDE 3/4" IMC PROVIDE WP CONDULET FOR EACH PARAPET PENETRATION. ROOF PENETRATION REFER TO 2/A142 PROVIDE ONLY (1) ROOF PENETRATION AT EACH EXTERIOR BUILDING S LOCATION. REFER T POWER DISTRIBUTION BOX PROVIDED BY SIGN VENDOR PARAPET EXTERIOR WALL BUILDING SIGN CONDUIT PENETRATION DETAIL SCALE: NOT TO SCALE LED MOUNTING CLIP SCALE: NOT TO SCALE CONTACT (TYP.) ROOF PENETRATION REFER TO 2/A142 PROVIDE ONLY (1) ROOF PENETRATION AT EACH EXTERIOR BUILDING SIGN LOCATION. BUILDING SIGN CONDUIT ELEVATION DETAIL SCALE: NOT TO SCALE FLOOR TYPE 'A' . _`OR BOXES OPTICAL CASH WRAP FIXTURE #WF4002 E521 / SCALE: NOT TO SCALE TIE WIRE LED GUIDE AND LIGHT ENGINE PLASTIC MOUNTING CLIP SPACED 5" TO 8" ON CENTER RG -11 COAX CABLE PROVIDED BY TARGETS LOW VO`_TAG= VENDOR COAX CABLE ROUTED BY TARGETS LOW VO_T. VENDOR TO LOUNGE T`;i LOCATED IN ROOM 137 HDTV ANTENNA MAST DETAIL SCALE: 1/4" = 3/8". LED LIGHT ENGINE CONNECTION HDTV ANTE*E PROVIDED BY TARGETS T. INSTALLATION VENDOR OD SI D PIPS ENNA .(EFERTO 11514:1 AND 1415522 GROUND `t€J ..iv KIT PROVIDED BY TARGET'S ET: S 5TVINSTALLATION VENDOR GTE: RG -11 COAXIAL CONNECTORS PROVIDED TARGET'S I-Ri;''�1Llv TV INSTALLATION VENDOR LED MOUNTING CLIP LED LIGHT GUIDE AND LIGHT ENGINE LED LIGHT GUIDE CONNECTOR TWIST ON WIRE CONNECTOR, FOLD WIRES BEHIND LIGHT ENGINE TO NOT BE VISIBLE SCALE: NOT TO SCALE LOCATE J BOX ABOVE GLAZING 16 \ NOT USED E521 l SCALE: NOT TO SCALE STORE FRONT DOOR CONTACT WIRING SCALE: NOT TO SCALE WALL ETR COLUMN - .IBL - CONDUIT INSIDE .i._...., SLOT i \i E: ''STALL.Vs':`:tl%. :"'i':Li :: i`rE i.: 1-LUGMOI_.. 2000^ €^ •Ji•�.�iE`_".:. STEEL .... fl`E i... ._ ...i :.i f_t.�_.. ASSEMBLY .�V_.iE._i..,..'E E"'i .x k20G IB5,..T i\.J-.BA C € ,. SUBSTITUTION;. ALLOWED) INST.iLL _CI`.LA. 3I`..' I_ACK. FINISH WITHiiTERNATING i_,,.✓F. T AC L..; _RAND ilvf. OI :._ CENTERS. :SST- ! ALL NECESSARY w .. _I NGn , CONNECTORS . COVER CLI, v:,::DFCR ,,(✓N.v_2f.ti.FEACH .. .>~.Tiv`-'v, MULTIOULET..S..,r-;'Bv. v,: r.,• CONTACT GRAYRAR TO ORDER CUSTOM STARDUCKS ,PLUG;IVIOI D. CONTACT IO INSTALL FACING. ,..UES.I. COUNTER TOE OVE. i S/ h -f v. lOUTLETS 3y COORDINATE . ROU i _tl`r/� � OF w. ,.i. <.., ,..:I . . t. . OF FIXTURE T ,rte-:'JRAND FIXTURE RE SH O INSTALLATION OF THE FIXTURE, ! IC_..SB : ,. ..... .. ..`, 1.ODOR O. CONDUIT',/\/K i IX AND FIX,TU S. . N I_.THE •..: ifie 1 TIO ._ 3 ii E M i )t. e v UPE CONTRACTOR pRoVIDEox RECESSED iN __..ECTRICAL. CONINECTION TO COUNTER N f,,I,E;TAL. COVER PLATE V4i CENT K N. .H.OU PROVIDE IDE CONNEC 1 ION TO PLUG.,,OL.J INSTALLED ON COUNTER FRONT FROM UNDERFLOOR WHEN EXTERIOR WALL. !S NOT ACCESSIBLE BECAUSE OF EXISTING ING SI f E.. CONDITIONS. ...S..._L POWER CON ./.S .£.:... {ter, SE- OX SE?: PRO\iis t IECTIC I' . _3i..m>if`;LLED;,f COUNTER FROFROM UNDERFLOOR WHEN EX ERI OR WAIL IS NOT ACCESSIBLE BECAUSE OF EXISTING .,.E CONDITIONS INSTALL >C__€:. .. . .;GL._Y BELOW `-�E,'OVERHANG WITH OUT FACING GUEST. SEATING COUNTER BAR DETAIL 0011 REVIEWED FOR COMPLIANCE ITH NFPA 70 - DEC 13 nil City of Tukwila BUILDING DIVISION�� RECEIVED CITY OF TUKWILA NOV 21 2017 ?ERMLT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO ( O V CO W co Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DETAILS E521 11/17/2017 3:49:18 PM NOTE: 4 III CEILING WIRING€(TYP) ACCESSIBLE SEE CONDUIT ® (TYP.) REQUIREMENTS J 5 -----------..„,,,ii:\_ li 11 11 MAGNET (TYP.) SWING DOOR SWING DOOR SWING DOOR SWING DOOR GLAZING 16 \ NOT USED E521 l SCALE: NOT TO SCALE STORE FRONT DOOR CONTACT WIRING SCALE: NOT TO SCALE WALL ETR COLUMN - .IBL - CONDUIT INSIDE .i._...., SLOT i \i E: ''STALL.Vs':`:tl%. :"'i':Li :: i`rE i.: 1-LUGMOI_.. 2000^ €^ •Ji•�.�iE`_".:. STEEL .... fl`E i... ._ ...i :.i f_t.�_.. ASSEMBLY .�V_.iE._i..,..'E E"'i .x k20G IB5,..T i\.J-.BA C € ,. SUBSTITUTION;. ALLOWED) INST.iLL _CI`.LA. 3I`..' I_ACK. FINISH WITHiiTERNATING i_,,.✓F. T AC L..; _RAND ilvf. OI :._ CENTERS. :SST- ! ALL NECESSARY w .. _I NGn , CONNECTORS . COVER CLI, v:,::DFCR ,,(✓N.v_2f.ti.FEACH .. .>~.Tiv`-'v, MULTIOULET..S..,r-;'Bv. v,: r.,• CONTACT GRAYRAR TO ORDER CUSTOM STARDUCKS ,PLUG;IVIOI D. CONTACT IO INSTALL FACING. ,..UES.I. COUNTER TOE OVE. i S/ h -f v. lOUTLETS 3y COORDINATE . ROU i _tl`r/� � OF w. ,.i. <.., ,..:I . . t. . OF FIXTURE T ,rte-:'JRAND FIXTURE RE SH O INSTALLATION OF THE FIXTURE, ! IC_..SB : ,. ..... .. ..`, 1.ODOR O. CONDUIT',/\/K i IX AND FIX,TU S. . N I_.THE •..: ifie 1 TIO ._ 3 ii E M i )t. e v UPE CONTRACTOR pRoVIDEox RECESSED iN __..ECTRICAL. CONINECTION TO COUNTER N f,,I,E;TAL. COVER PLATE V4i CENT K N. .H.OU PROVIDE IDE CONNEC 1 ION TO PLUG.,,OL.J INSTALLED ON COUNTER FRONT FROM UNDERFLOOR WHEN EXTERIOR WALL. !S NOT ACCESSIBLE BECAUSE OF EXISTING ING SI f E.. CONDITIONS. ...S..._L POWER CON ./.S .£.:... {ter, SE- OX SE?: PRO\iis t IECTIC I' . _3i..m>if`;LLED;,f COUNTER FROFROM UNDERFLOOR WHEN EX ERI OR WAIL IS NOT ACCESSIBLE BECAUSE OF EXISTING .,.E CONDITIONS INSTALL >C__€:. .. . .;GL._Y BELOW `-�E,'OVERHANG WITH OUT FACING GUEST. SEATING COUNTER BAR DETAIL 0011 REVIEWED FOR COMPLIANCE ITH NFPA 70 - DEC 13 nil City of Tukwila BUILDING DIVISION�� RECEIVED CITY OF TUKWILA NOV 21 2017 ?ERMLT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO ( O V CO W co Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DETAILS E521 11/17/2017 3:49:18 PM PROVIDE UNISTRUT CROSS MEMBERS TO MOUNT _.!GH . FIXTURES BETWEEN CENTER RACKING SUPPORTS CENTER RACKING G S.i P PORTS TYPE "CIL' LIGHT FIXTURE LOCATED BETWEEN WEEN _ A...L_.. RACKING IEN R SUPPORTS. FIXTURE WIRE ....rr.Rry TO BP FLUSH WITH H , OTTOM OF STRUCTURE i _\TERBACKING SE ;PPOR 1 PALLET RACKING LIGHT FIXTURE MOUNTING E531 SCALE: NOT TO SCALE NOTE: POWER CONDUCTORS GREATER THAN 70 VOLTS ARE REQUIRED TO BE IN FLEXIBLE CONDUIT MANUFACTURED STARTER AND CABLE KIT POWER SOURCE J -BOX MOUNTED ON STRUCTURE ABOVE ACCESSIBLE CEILING ROUTE CABLE KIT TO BASE DECK OF FIXTURE AND TERMINATE IN J -BOX FOR MAIN POWER FED TO FIXTURE PASS THRU CABLE KIT ROUTED TO BASE DECK OF FIXTURE NYLON BUSHING CEILING TRIM KIT CEILING T -BAR SYSTEM POWER POLE ACCESS PANEL W/ 1/2" KNOCK -OUT ON EACH END 7 POWER POLE TYPE "a" INSTALLATION DETAIL E531 SCALE: NOT TO SCALE HOMERUN 1 1/4" EMC #10 NO SPLICES CEILING u H REFRIGERATED CASE FRONT VIEW SCALE: NOT TO SCALE POLE _ _. E ,';': i €F -QUIP;.< iLI'CE -`'TAC - (NOT() ) 1`2„: .; U NC,TION !BOXES el RC I. REFER TO MANUFACTURERS INSTALLATION INSTRUCTION DOCUMENTS FOR WIRING AND MOUNTING REQUIREMENTS FOR VALANCE LIGHTS. CEILING ( ii l n CHECKLANE KEY NOTES KE53/ ''' - 5331 B PROVIDE FLEX WIRING AND ROUTE VIA POWER SECTION OF POWER POLE AND MAKE CONNECTIONS IN LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. E53) VENDOR. PROVIDE CONNECTIONS INSIDE LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. D ROUTE FLEX WIRING (FURNISHED WITH POWER POLE) AND MAKE HARDWIRE CONNECTION TO CONVENIENCE POWER JUNCTION BOX INSIDE CHECKLANE. E DEVICE & FLEX WIRING FURNISHED & PREWIRED AT DEVICE BY CHECKLANE VENDOR. PROVIDE CONNECTIONS IN LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. F DEVICE & FLEX WIRING FURNISHED & PREWIRED BY CHECKLANE VENDOR. FINAL STORE FIXTUI ! 8'-6„ CENTER OF CONDUIT STUB OUT FINAL STORE FIXTURE PLAN 8'-1" 71 U J VERIFY ELEVATION WITH FINAL STORE FIXTURE PLAN -n r- 0 0 0 7'-6" CENTER OF CONDUIT STUB OUT A + A VALANCE LTG'S AT PERIMETER WALL FOCAL VALANCE LTG'S AT PERIMETER WALL HARDL NES VALANCE LTG'S AT PERIMETER WALL 2� PERIMETER WALL VALANCE LIGHTING SECTIONS REFRIGERATION VALANCE LTG'S AT PERIMETER WALL SCALE: NOT TO SCALE NOTE: POWER CONDUCTORS GREATER THAN 70 VOLTS ARE REQUIRED TO BE IN FLEXIBLE CONDUIT MANUFACTURED STARTER AND CABLE KIT POWER SOURCE J -BOX MOUNTED ON STRUCTURE ABOVE ACCESSIBLE CEILING POWER POLE TYPE "b" PROVIDED WITH (1) DUPLEX RECEPTACLE. POWER POLE TYPE "c" PROVIDED WITH (2) DUPLEX RECEPTACLES. ROUTE CABLE KIT TO BASE DECK OF FIXTURE AND TERMINATE IN J -BOX FOR MAIN POWER FED TO FIXTURE POWER POLE 8T TYPE "b" & "c" INSTALLATION DETAIL PASS THRU CABLE KIT ROUTED TO BASE DECK OF FIXTURE POWER POLE TYPE "b" & "c" ARE PROVIDED WITH PRE-INSTALLED CABLE KIT CONNECTED TO PRE-INSTALLED POWER POLE RECEPTACLE NYLON BUSHING CEILING T -BAR SYSTEM CEILING TRIM KIT POWER POLE ACCESS PANEL WI 1/2" KNOCK -OUT ON EACH END E531 / SCALE: NOT TO SCALE 1 1/4" EMT LOW VOLTAGE FALSE COLUMN PROVIDE 6" X 6" PULL BOX, FASTEN TO TOP OF REFRIGERATED CASE REFRIGERATED CASE (2)1" EMT taw - LJ (2)1" FLEX TERMINAL STRIP IN WIREWAY WIRING/CONDUIT BETWEEN CASES IF NO WIREWAY HOMERUN 1 1/4" EMC #10 NO SPLICES PROVIDE 6" X 6" PULL BOX, FASTEN TO TOP OF REFRIGERATED CASE (2) 1" FLEX (2) 1" EMT OR FLEX (2) 1" FLEX JUNCTION BOX 11 E531 CENTER OF CONDUIT STUBOUT CEILING TYPE VL6 LTG FIXTURE 0 N CENTER OF CONDUIT STUB OUT CEWNG TYPE VL6 LTG FIXTURE FLOOR PARTNER BUSINESS VALANCE LTG'S @ STARBUCKS BULKHEAD PARTNER BUSINESS VALANCE LTG'S @ PHARMACY BULKHEAD REFER TO MANUFACTURERS INSTALLATION INSTRUCTION DOCUMENTS FOR WIRING AND MOUNTING REQUIREMENTS FOR VALANCE LIGHTS. 3 E531 PARTNER BUSINESS LIGHTING SECTIONS SCALE: NOT TO SCALE 9T POWER POLE MOUNTING DETAIL POWER POLE FOOT BRACKET ANCHOR FOOT BRACKET TO FIXTURE WITH 1/4" X 1/2" PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE. CENTER FOOT BRACKET OVER PRE -PUNCHED KNOCK -OUT PROVIDED WITH FIXTURE TOP CAP. PUNCH FIXTURE TOP CAP IF KNOCK -OUT IS NOT PRESENT. E531 / SCALE: NOT TO SCALE (2)1" EMT ATTACHED TO REFRIGERATED CASE T 17 \ IGS CHECKLANE SCANNER REC'_. C.EFT,AOLE (I R' E531 / SCALE: NOT TO SCALE -•r�r•r•r•/•r r • ROOF ( (_Irl( rlrl/ l( J RUN WIRE THRU COLUMN NOTE: LABEL DUCT DETECTOR HOUSING AND REMOTE TEST SWITCH FOR IDENTITY. INDICATE RTU # AND POINT NUMBER B DUCT WORK DUCT SMOKE DETECTOR REMOTE TEST SWITCH MOUNT IN SINGLE GANG BOX ON THE SAME COLUMN AS THE RESPECTIVE HVAC THERMOSTAT, UNLESS OTHERWISE INDICATED. PULL WIRE THRU GROMMET ON COLUMN. COORDINATE WITH ELECTRICAL CONTRACTOR. REFER TO DUCT SMOKE DETECTOR REMOTE TEST STATION LOCATION DETAIL SCALE: NOT TO SCALE D ON TRACK {2202A -L) ':EON BY E,......a I RI4.jt M BE FLOOR MAGNET MOUNTED ON TOP 'OF FLANGE MAGNETIC DOOR MONITORING CONTACT FOR COILING DOOR SCALE: NOT TO SCALE H C REFRIGERATED CASE SIDE VIEW SCALE: NOT TO SCALE ....»D i........ LIGHT LANE LIGHT IT CHe POWER TELIDATA CEILING FALSE COLUMN PROVIDE 6" X 6" PULL BOX, FASTEN TO TOP OF REFRIGERATED CASE (2) 1" FLEX ROUTE POWER CORD FOR GONDOLA DISPLAY THROUGH. HOLES TO RECEPTACLE LOCATED UNDERNEATH BASE DECK. DRILL 2" HOLE IN BASE DECK, PROVIDE BUSHING GONDOLA BASE DECK RECEPTACLE POWER ROUTED UNDER BASE DECK TO POWER POLE UP TO JUNCTION BOX ABOVE CEILING. GONDOLA GONDOLA BASE DECK UNDER BASE DECK RECEPTACLE DETAIL SCALE: NOT TO SCALE CONNECTOR BRACKET FURNISHED BY FIXTURE VENDOR MAKE CONNECTION TO LIGHTING FIXTURE ROUTE MC CABLE VIA FIXTURE CHANNEL POWER POLE INSTALL POWER POLE MOUNTING BRACKET FURNISHED WITH POWER POLE FLUORESCENT VALANCE LIGHTING FURNISHED AND INSTALLED BY FIXTURE VENDOR 10T GREETING CARDS LIGHT FIXTURE DETAIL E531 / SCALE: NOT TO SCALE GUEST SIDE T8� IGS CHECKLANE POWER POLE E53� SCALE: NOT TO SCALE REAR SIDE (TOWARDS REAR OF STORE) FRONT SIDE (TOWARDS FRONT OF STORE) LED LANE LIGHT LED DRIVER SWITCH LOCATIONS AT 58" AFF LANE LIGHT CHANNEL POWER CHANNEL TELE/DATA CHANNEL RIGHT HAND CHECKLANE POWER POLE SCALE: NOT TO SCALE 1 444444411411004144414,44.114111,11,114 t11111 tv COOLER/FREEZER INSULATED CEILING PANEL T FRONT VIEW LIGHT FIXTURE MOUNTING BRACKET. MOUNT BRACKET TO PANEL UTILIZING HILTI KWIK-PRO #12-14 HWH SELF -DRILLING TWO (2) SCREW, 3/4” IN LENGTH WITH ZINC COATED FINISH OR EQUAL PROVIDE EMT TO LIGHT FIXTURES (TYP) PROVIDE LB AT CONDUIT PENETRATION SIDE VIEW viteee44.4.1 BRACKET SPACING REQUIRED. 4' HOUSING - 36" BETWEEN BRACKETS 8' HOUSING - 49" BETWEEN BRACKETS NOTES: WALK-IN COOLER/FREEZERS ARE CONSIDERED WET INTERIOR LOCATION, PROVIDE EMT INSIDE OF COOLER/FREEZERS FOR LIGHTS ONLY. PROVIDE EMT FOR POWER FEED TO COOLER/FREEZER LIGHT FIXTURES. POWER FEED SHOULD ONLY PENETRATE COOLER /FREEZER ONCE AND BE CONNECTED AT EACH END OF LIGHT FIXTURE. SEAL PENETRATION WITH SILICONE CAULK. REFER TO SPECIFICATION SECTION 07 9200. REFER TO SPECIFICATION SECTION 26 0533 - 3.3 FOR CONDUIT USES PERMITTED. COOLER/FREEZER LIGHT FIXTURE MOUNTING DETAIL SCALE: NOT TO SCALE NOTE: ti VERIFY LOCATION OF VALANCE WITH ELECTRICAL FLOOR PLANS AND FINAL STORE FIXTURE PLAN. WHEN FIXTURE INSTALLATION IS COMPLETE. ENERGIZE VALANCE LIGHT FIXTURE AND ENSURE PROPER OPERATION OF EACH VALANCE LIGHT FIXTURE. SURFACE MOUNT JUNCTION BOX 12" ABOVE LAY -IN CEILING ON EXTERIOR WALLS, MOUNT ON TOP PLATE OF INTERIOR WALLS. CEILING N N N. 11 FOCAL LIGHTING VALANCE PROVIDE 3/8" MC FROM J -BOX MTD ABOVE CEILING TO 90 DEG. SNAP - IN CONNECTOR. GYP BD PROVIDE PLASTIC 01 RUBBER GROMMET 3/8" 90 DEG. SNAP -IN MC CONNECTOR PROVIDED BY OWNER. INSTALL VALANCE LIGHT AND CONNECT WIRING HARNESS PER MANUFACTURERS INSTALLATION INSTRUCTION. PROVIDE FINAL ELECTRICAL CONNECTION TO VALANCE LIGHT FIXTURE WIRING HARNESS PER MANUFACTURERS INSTALLATION INSTRUCTION. E531 SCALE: NOT TO SCALE F E E MOTOR CAPACITOR BOX (BELT MOTOR STARTER) MAINT. RECEPTACLE (GRAY) SCANNER RECEPTACLE (IVORY) TRI-TRONICS UNIT (CHECKLANE CONTROLLER) (3) 4" X4" J -BOXES COOLER RECEPTACLE (GRAY) F B BELT SWITCH (1) CONV. CIRCUIT INPUT FLEX, (1) COOLER CIRCUIT INPUT FLEX & (1) STANDBY/GEN CIRCUIT INPUT FLEX WIRING IM FRONT SECTION D A E F LANE LIGHT FLEX WIRING POWER POLE & LANE LIGHT ASSEMBLY CEILING 0 MAIN AISLE JUNCTION BOX POWER & DATA CABLE ROUTED THROUGH POWER POLE TO JUNCTION BOX ABOVE CEILING SECURE POWER POLE TO TOP OF MAC PRICE SCANNER MAC PHONE MINI -ASSISTANCE CENTER (MAC) DETAIL 53� SCALE: NOT TO SCALE POS RECEPTACLE (IVORY) CATALINA PRINTER RECEPTACLE (IVORY) REAR SECTION WHITE TO REAR SECTION POS RECEPTACLE (IVORY). (NEUTRAL) TO SCANNER RECEPTACLE (IVORY). (FLEX PREWIRED CONNECT FLEX WIRING FURNISHED BY VENDOR. i TO J -BOX BY VENDOR). GREEN (GND) STANDBY/GENERATOR POWER INPUT CIRCUIT (LPE-1 OR UPS -1) . PROVIDE FLEX WIRING AND CONNECT. COMPUTER EQUIPMENT (POS/SCANNER POWER) BLACK (HOT) TO MAINTENANCE RECEPTACLE (GRAY). (FLEX PREWIRED TO J -BOX BY VENDOR). GREEN (GND) WHITE (NEUTRAL) BLACK (HOT) TO LANE LIGHT CIRCUIT (LP -3). ' CONVENIENCE INPUT CIRCUIT (LP -3). PROVIDE FLEX CONNECT FLEX WIRING FURNISHED BY WIRING & CONNECT. VENDOR. CHECKSTAND (CONVENIENCE POWER) TO COOLER RECEPTACLE (GRAY). (FLEX PREWIRED TO J -BOX BY VENDOR). CHECKLANE SCALE: NOT TO SCALE GREEN (GND) WHITE (NEUTRAL) BLACK (HOT) COOLER INPUT CIRCUIT (LP -3). PROVIDE FLEX WIRING AND CONNECT. SODA COOLER (COOLER POWER) (3) 4" x 4" JUNCTION BOXES ?Lfl CHECKLANE GENERAL NOTES A. CHECKLANE FURNISHED WITH JUNCTION BOXES, DEVICES & WIRING AS INDICATED. B. TELEPHONE AND POS DATA CABLE BY VOICE/DATA CONTRACTO',0 C. CHECKLANE POWER POLE SWITCHES, FLEX WIRING, LANE LIGHT ASSEMBLY, FURNISHED BY POWER POLE VENDOR. D. COORDINATE LIGHT FIXTURE LOCATIONS WITH CASH REGISTER POWER POLES. WHERE NECESSARY MOVE LIGHT FIXTURES TO AVOID POWER POLES. MOVE LIGHT FIXTURES IN THE SAME DIRECTION. E. GRAY CIRCUIT INDICATES NORMAL POWER FED FROM LP -3. IVORY CIRCUIT INDICATES STANDBY/GENERATOR POWER FED FROM LPE-1 OR UPS -1. F. (3) LABELLED JUNCTION BOXES (CHECKLANE) FURNISHED AND MOUNTED ON SIDE PANEL OF CHECKLANE BY CHECKLANE VENDOR. CHECKLANE KEY NOTES A INSTALL CHECKLANE SIGN PRIOR TO INSTALLATION OF POWER POLE TO CHECKLANE. ONCE SIGN IS INSTALLED, INSTALL AND SECURE BOTTOM OF POWER POLE TO CHECKLANE WITH MOUNTING BRACKET FURNISHED BY POWER POLE VENDOR. SECURE TOP OF POWER POLE PER DETAIL B PROVIDE FLEX WIRING AND ROUTE VIA POWER SECTION OF POWER POLE AND MAKE CONNECTIONS IN LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. C JUNCTION BOXES FURNISHED AND INSTALLED BY CHECKLANE VENDOR. PROVIDE CONNECTIONS INSIDE LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. D ROUTE FLEX WIRING (FURNISHED WITH POWER POLE) AND MAKE HARDWIRE CONNECTION TO CONVENIENCE POWER JUNCTION BOX INSIDE CHECKLANE. E DEVICE & FLEX WIRING FURNISHED & PREWIRED AT DEVICE BY CHECKLANE VENDOR. PROVIDE CONNECTIONS IN LABELLED JUNCTION BOXES INSIDE OF CHECKLANE. F DEVICE & FLEX WIRING FURNISHED & PREWIRED BY CHECKLANE VENDOR. 06qg REVIEWED COMPLIANCE .-,_; NFPA 7n. f! "-,:,°91117 City f.Tukwii BUILDING MIT RECEIVED CITY OF TUKWILA NOV a 1 2017 PERMIT CENTER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO N"'"' CO 14CJ 0 co W I.L. 0 f �� VJ Cr) Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DETAILS E531 11/17/2017 3:49:21 PM CEILING 3/4" CONDUIT FOR DATA CABLE CONNECTION TO CONTENT DEVICE FLOOR DATA OUTLET FOR CONTENT DEVICE RECEPTACLE FOR CONTENT DEVICE CONTENT DEVICE • OWNER PROVIDED UL LISTED, 15AMP FUSED POWER STRIP DISTRIBUTION AMPLIFIER HDMI DISTRIBUTION AMPLIFIER FIXTURE ADJACENT FIXTURE 1 TV WALL ELEVATION E541 SCALE: 1/4" = 1'-0" 4 MOUNT POWER JUNCTION BOX IN BASE DECK OF TV WALL. PROVIDE CONDUIT FROM BASE DECK JUNCTION BOX TO POWER JUNCTION BOX MOUNTED IN TV WALL (TYPICAL) CD = CONTENT DEVICE DA = DISTRIBUTION AMPLIFIER P = POWER JUNCTION BOX - WITH DUPLEX RECEPTACLE FUTURE EXPANSION HDMI DISTRIBUTION FIXTURE LOCATION • I- 0 I- w U w 0 J INSTALL PRE -MANUFACTURED RECEPTACLE INSIDE OF FIXTURE. MOUNT RECEPTACLE TO RAIL OF FIXTURE WITH 1/4" X 1" PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED. ROUTE PRE -MANUFACTURED WIRING IN BASE DECK OF FIXTURE SUPPORT PRE MANUFACTURED CONNECTORS A MINIMUM OF 3" ABOVE FINISHED FLOOR FROM UNDERSIDE OF BASE DECK TO AVOID MOISTURE FROM PENETRATING CONNECTIONS. SUPPORT CONNECTOR ON EACH END UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. ELECTRONICS - TYPICAL WIRING ELEVATION POWER DETAIL E541 CEILING SCALE: NOT TO SCALE n FLOOR 4- 60 to \ \ , 1 1 1 1 1 1 1 1 1 1 H I I 00 0 1E1 I © C3 -El 12E1–C-1:7+ra-CI– 0 ) \ J I I I I I 1 1 I I I I 1 I I I 1 1 --------1--- _I 56". WALL DEVICE MTD HTS 95". / ph-, I I I 0 I I I PY I I I PY I I I I I P Y I I I i I IDLE' I I I I I I PY I 1 I I I I PY - - - 1 1 1 TV MOUNTING CRC 65". -V MOUNTING CROSSBAR 00 9 00' 00 w 00 e P I DA I I I I I P� DA PI DA 1 I I I I CD (Z� DA cc L -" w G z 00 P�I DA I I I I PI DA I I I I I 171:7, LDE4 --- 1---- I I I I I I I I I I I I I I I I I I I I I I I I I I I --U -- — — -- _J L - -U-- - - --_J o b--LJ�'— —— -- ----- 1 TV WALL ELEVATION E541 SCALE: 1/4" = 1'-0" 4 MOUNT POWER JUNCTION BOX IN BASE DECK OF TV WALL. PROVIDE CONDUIT FROM BASE DECK JUNCTION BOX TO POWER JUNCTION BOX MOUNTED IN TV WALL (TYPICAL) CD = CONTENT DEVICE DA = DISTRIBUTION AMPLIFIER P = POWER JUNCTION BOX - WITH DUPLEX RECEPTACLE FUTURE EXPANSION HDMI DISTRIBUTION FIXTURE LOCATION • I- 0 I- w U w 0 J INSTALL PRE -MANUFACTURED RECEPTACLE INSIDE OF FIXTURE. MOUNT RECEPTACLE TO RAIL OF FIXTURE WITH 1/4" X 1" PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED. ROUTE PRE -MANUFACTURED WIRING IN BASE DECK OF FIXTURE SUPPORT PRE MANUFACTURED CONNECTORS A MINIMUM OF 3" ABOVE FINISHED FLOOR FROM UNDERSIDE OF BASE DECK TO AVOID MOISTURE FROM PENETRATING CONNECTIONS. SUPPORT CONNECTOR ON EACH END UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. ELECTRONICS - TYPICAL WIRING ELEVATION POWER DETAIL E541 CEILING SCALE: NOT TO SCALE n FLOOR 4- 60 to \ \ , 1 1 1 1 1 1 1 1 1 1 H I I 00 0 1E1 I © C3 -El 12E1–C-1:7+ra-CI– 0 ) \ I I I I I L I I I I I 1 1 I I I I 1 I I I 1 1 --------1--- _I 7 SHOWCASE WALL ELEVATION PROVIDE 1" CONDUIT STUBBED ABOVE CEILING PROVIDE DATA OUTLET FOR CONTENT PLAYER PROVIDE 20A RECEPTACLE PROVIDE 4'-0" MULTIOUTLET ASSEMBLY WITH OUTLETS 6" ON CENTER. MOUNT MULTIOUTLET ASSEMBLY TO GONDOLA FIXTURE UPRIGHTS. E541 / SCALE: NOT TO SCALE POS PHONE OUTLET POS POWER OUTLET ROOF JOIST **PROVIDE SEISMIC BRACING** 1/2" ALLTHREADED ROD WITH 2" WASHER AND DOUBLE NUTS BOTH ENDS. ELECTRICAL TRANSFORMER VERIFY DIMENSION' W/UNIT. SECURE TRANSFORMER TO STRUTS. PROVIDE ISOLATION PADS ROOF DECK ROOF JOIST UNI -STRUT P1000 CHANNEL. LENGTHS AS REQUIRED FOR JOIST SPAN. TYPICAL OF TWO. CLAMP TO JOISTS WITH P1379S CLAMPS. UNI -STRUT P1000 HS CHANNEL TYPICAL OF TWO. VERIFY LENGTH WITH UNIT DIMENSIONS. 2 TRAPEZE MOUNT TRANSFORMER E541 1 SCALE: NOT TO SCALE \ \ POS POWER & DATA OUTLETS • • • • • • • \ • • • • POWER & DATA FLOOR BOXES • • • • • • • • • 9 • • / • \ • • \ • • • \ \ • • \o • • / 00 00 POS POWER & DATA OUTLETS LED SIGN OUTLET POS PHONE OUTLET POS POWER & DATA OUTLETS PRINTER POWER & DATA OUTLETS TARGET MOBILE POWER & DATA OUTLETS 13 NOT USED O's ‘-‘ E541 SCALE: NOT TO SCALE 0) 0o \ / 00 0 9 / 0 9 O O • • • • • • • \ • • • • POWER & DATA FLOOR BOXES • • • • • • • • • 9 • • / • \ • • \ • • • \ \ • • \o • • / 00 00 POS POWER & DATA OUTLETS LED SIGN OUTLET POS PHONE OUTLET POS POWER & DATA OUTLETS PRINTER POWER & DATA OUTLETS TARGET MOBILE POWER & DATA OUTLETS 13 NOT USED O's ‘-‘ E541 SCALE: NOT TO SCALE 0) POWER & DATA FLOOR BOXES TABLET POWER 5 ELECTRONICS FRONT SERVICE COUNTER ELEVATION E541 SCALE: NOT TO SCALE 60 -AFF .0 /1 60"AFF PRE MANUFACTURED MAINRUN CABLE. PRE MANUFACTURED DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN FIXTURE. TYP. 60"AFF 60"AFF 60"AFF LENGTH OF GONDOLA WILL VARY ROUTE PRE -MANUFACTURED WIRING IN BASE DECK OF FIXTURE SUPPORT PRE -MANUFACTURED CONNECTORS A MINIMUM 3" ABOVE FINISHED FLOOR FROM UNDERSIDE OF DECK TO AVOID MOISTURE FROM PENETRATING CONNECTORS. SUPPORT CONNECTORS ON EACH END UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. 8 BEAUTY BLOWOUT RECEPTACLE - TYPICAL WIRING E541 1 SCALE: NOT TO SCALE 6 ELECTRONICS BACK SERVICE COUNTER ELEVATION 41 SCALE: NOT TO SCALE PRE MANUFACTURED MAINRUN CABLE. PRE MANUFACTURED DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN FIXTURE. TYP. LENGTH OF GONDOLA WILL VARY II 9\ BEAUTY PLUGSTRIP - TYPICAL WIRING INSTALL OWNER FURNISHED RELOC WIRING SYSTEM EXTENDER CABLES IN BOTTOM OF MULTI -OUTLET ASSEMBLY J -BOX. PROVIDE FINAL CONNECTION USING IDEAL CONNECTORS PROVIDED WITH MULTI -OUTLET ASSEMBLY KIT. ,54) SCALE: NOT TO SCALE 10 TYPICAL GONDOLA ISOMETRIC VIEW GENERAUFIXTURE CONTRACTOR TO VERIFY IF END CAP DISPLAY REQUIRES POWER &SYSTEMS. PROVIDE 2" HOLE THROUGH END FRAME PEG BOARD DIRECTLY BEHIND DISPLAY WERE CORD EXITS THE DISPLAY. PROVIDE GROMMETS TO PROTECT POWER & SYSTEMS CABLES. GROMMET COLOR SHALL MATCH FIXTURE COLOR. RECEPTACLE MOUNTED UNDER BASE DECK TO FIXTURE RAIL ARM MOUNT BASE DECK RECEPTACLE TO FIXTURE RAIL WITH 1/4 " X 1" PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED • TYPICAL GONDOLA RAIL MAINTAIN 3 1/2" OF CLEARANCE FROM BACK OF FIXTURE RAIL WHEN INSTALLING BASE DECK RECEPTACLE. RECEPTACLE INSTALLED UNDER BASE DECK E541 / SCALE: NOT TO SCALE t L17 _ Q6g4 \\_____ REVIEWED COMPLIANFPA� CE' � or,.1 Q /1111 Gity ©o'Tukw BUILDING DMS RECEIVED CITY OF TUKWIL A NOV 2 1 2017 PERMIT -.:,?: 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DETAILS E541 11/17/2017 3:49:23 PM \ / / O O 0 0 00 9 00' 00 00 e 00 9 00 I Io POWER & DATA FLOOR BOXES TABLET POWER 5 ELECTRONICS FRONT SERVICE COUNTER ELEVATION E541 SCALE: NOT TO SCALE 60 -AFF .0 /1 60"AFF PRE MANUFACTURED MAINRUN CABLE. PRE MANUFACTURED DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN FIXTURE. TYP. 60"AFF 60"AFF 60"AFF LENGTH OF GONDOLA WILL VARY ROUTE PRE -MANUFACTURED WIRING IN BASE DECK OF FIXTURE SUPPORT PRE -MANUFACTURED CONNECTORS A MINIMUM 3" ABOVE FINISHED FLOOR FROM UNDERSIDE OF DECK TO AVOID MOISTURE FROM PENETRATING CONNECTORS. SUPPORT CONNECTORS ON EACH END UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. 8 BEAUTY BLOWOUT RECEPTACLE - TYPICAL WIRING E541 1 SCALE: NOT TO SCALE 6 ELECTRONICS BACK SERVICE COUNTER ELEVATION 41 SCALE: NOT TO SCALE PRE MANUFACTURED MAINRUN CABLE. PRE MANUFACTURED DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN FIXTURE. TYP. LENGTH OF GONDOLA WILL VARY II 9\ BEAUTY PLUGSTRIP - TYPICAL WIRING INSTALL OWNER FURNISHED RELOC WIRING SYSTEM EXTENDER CABLES IN BOTTOM OF MULTI -OUTLET ASSEMBLY J -BOX. PROVIDE FINAL CONNECTION USING IDEAL CONNECTORS PROVIDED WITH MULTI -OUTLET ASSEMBLY KIT. ,54) SCALE: NOT TO SCALE 10 TYPICAL GONDOLA ISOMETRIC VIEW GENERAUFIXTURE CONTRACTOR TO VERIFY IF END CAP DISPLAY REQUIRES POWER &SYSTEMS. PROVIDE 2" HOLE THROUGH END FRAME PEG BOARD DIRECTLY BEHIND DISPLAY WERE CORD EXITS THE DISPLAY. PROVIDE GROMMETS TO PROTECT POWER & SYSTEMS CABLES. GROMMET COLOR SHALL MATCH FIXTURE COLOR. RECEPTACLE MOUNTED UNDER BASE DECK TO FIXTURE RAIL ARM MOUNT BASE DECK RECEPTACLE TO FIXTURE RAIL WITH 1/4 " X 1" PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED • TYPICAL GONDOLA RAIL MAINTAIN 3 1/2" OF CLEARANCE FROM BACK OF FIXTURE RAIL WHEN INSTALLING BASE DECK RECEPTACLE. RECEPTACLE INSTALLED UNDER BASE DECK E541 / SCALE: NOT TO SCALE t L17 _ Q6g4 \\_____ REVIEWED COMPLIANFPA� CE' � or,.1 Q /1111 Gity ©o'Tukw BUILDING DMS RECEIVED CITY OF TUKWIL A NOV 2 1 2017 PERMIT -.:,?: 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA Project Number T-0627 Proto: P400 Version:V13A Config:RL Drawn By JLS Checked By TK ELECTRICAL DETAILS E541 11/17/2017 3:49:23 PM Key Notes 1. Contact Acuity Lighting, TargetTeam a Acuitybrands.com, 1-800-545-6817 2. Contact On -Site Lighting, Sharon Tokkesdal, sharon@onsitelighting.com, 1-763-684-1548 3. Contact Davis & Associates, Mike Brabeck, mike.brabeck@davisassociatesinc.com, 1-952-833-3512 4. Contact Icon International Inc., 1-888-557-1122 - Rebecca Entwistle, ext. 7050, rentwistle@iconintl.net, or David Horowitz, ext. 7525, dhorowitz@iconintl.net 5. Tandem fixtures 6. Fasten directly to wall with appropriate fasteners. 7. Owner furnished flexible wiring system, installed by contractor. 8. Lamp designed for use in open fixture, safety glass or lens not required. 9. Furnished by Target with store fixture package and intsalled by electrical contractor. Mounting hardware (screws and predrilled holes) included with packages. 10. Cut reflector to length. 11. Install in accordance with manufacturer's recommendation, do not violate the UL wet location listing. 12. Fixtures furnished with lamps installed. 13. Include hager bars for fixtures. 14. Specify nominal run length as indicated on type W1 run length spec sheet. 15. Coordinate fixture mounting requirements with manufacturer; J -box, wire rating, etc. 16. Provide silver metalic finish. 17. Provide a self flange trim. 18. Electrical contractor to install 3 custom pendant light fixture per track. 19. Watts listed in schedule are per track head. 20. Electrical contractor to email quantity of light fixtures and Store T# to Contact Atmosphere Interiors, Emily.Merriman@atmosphereci.com. 21. Contact Villa Lighting, Larry Wolf, larry.wolf@villalighting .com, 1-314-633-0542 22. Provide live end feed and mounting clips with track. 23. Provide a 1A current limiter device, current limiter live end feed, and mounting clips with track. 24. Use 2', 4', 6',8' and/or 12' lengths of track as required to meet total length of track as shown on the plans. 25. Fixture must be installed prior to Gyp installation. 26. Trim ring is field paintable. 27. Contact Focus Lighting Inc, Wes Schroeder, wgs@focuscos.com, 1-952-474-9077 28. OWNER FURNISHED FIXTURE. REFER TO BUSSTRUT SHOP DRAWINGS EMS CONTACTOR SCHEDULE DEVICE NUMBER LOCATION Light Fixture Schedule TYPE NUMBER OF POLES COUNT CONTACT VOLTAGE FIXTURE TYPE MANUFACTURER NOTES MANUFACTURER'S CATALOG NUMBER MOUNTING LAMPS BALLAST LIGHT CONTROL WATTS VOLTS KEY NOTES Al SALES FLOOR LIGHTING 2 0-1,2 2'X4' FLUORESCENT TROFFER LITHONIA 3,4,11,12,19,.20,27,20 2ES8PHE 232 277 AIPP QFC313X G835HT8 NATS RECESSED LAY -IN GE (2) F32T8XLSPX35HLECO IOPA NA 2P32 SC 12 CELL WHITE LOUVER 59 277 V 1, 7,12 A6L 5,0,13,14`1„22,29,30 49 120V 2'X4' LINEAR LENS LED TROFFER ACUITY-LITHONIA SALE S FL.00 LIGHTING 2RTL4 40L EZ1 LP835 N100 NATS RECESSED LAY -IN 3500K LED/4000 LUMEN DRIVER LINEAR FACETED REFLECTOR 39 277 V 1, 7 B1L SALES FLOOR LIGHT! G 7 0-1.5 2'X4' LED TROFFER ACUITY-LITHONIA 2Lo?6.'-,3,.29,30,3 32,33,35 2BLT4 30L ADSM EOHN LP835 IPS NATS RECESSED LAY -IN 3500K LED/3000 LUMEN DRIVER MIN. OF 0.125" ACRYLIC PRISMATIC LENS 25 277 V 1 B2L ALL3 3 €201 2'X4' LED TROFFER ACUITY-LITHONIA INTEGRAL WITH ElNEL�tC�%rf� 2BLT4 48L ADSM EOHN LP835 IPS NATS RECESSED LAY -IN 3500K LED/4800 LUMEN DRIVER MIN. OF 0.125" ACRYLIC PRISMATIC LENS 40 277 V 1 C12 -..:. ...: 23 .. ..... ..... ...y. 4' LED WET LOCATION IN COO ER IFR 'S .. .. ...„. ....,...- ,.-_.: .... LITHONIA _:__.. .... . _.. ALL VAP 4000LM FST MD MVOLT L/SP GZ10 40K 80CRI NATS -.,.. ,,... _. _._.,... .. _...._. - - -._.., SURFACE 4000K LED/4000 LUMEN _...,,Ar.«�,n-.R..�...:.Aewas......a....A.a�.1. DRIVER ..... UV STABILIZED CLEAR POLYCARBONATE 39 277 V 1,11 . D11 13 18 120V 6” LED DOWNLIGHT ACUITY-LITHONIA M wa rrarr iM4�'p. LDN6 35/20 LO6AR LD MVOLT EZ10 TRW .seow.Joao r....•�r .AA..-N1+,h p..A► ✓-..* RECESSED �+aaA{11w..- ,A0.- 3500K LED 2000 LUMEN ...---.`.*-"---.,. «,,«». -,_. -. ..Iwo . N€ra eon,. DRIVER �,, v..s.,._,,„, . p...ypMb►,. SPECULAR CLEAR 24 277 V 1 13,17 6 20 A ON Si•ORE OPEN If f i ERIOR 6" LED DOWNLIGHT ACUITY-LITHONIA .-_�ays.uwa. LDN6 35/15 LO6AR MVOLT EZ10 TRW RECESSED 3500K LED/1500 LUMEN DRIVER .t_ ,ou�av MATTE DIFFUSE a- .ba.:.� 26 277 V 1,13,17, 26 122R .§!12 7 120V 8" LED DOWNLIGHT RETROFIT .* ACU C..TED 1T TO CON CAB, 1 LOCATED 8 35! 0 RO8 ARID MV•LT 'W - C S �' Mint! irnOL MEN I.Il.._ ITFa ,2 277 V 1,13,17, a6 20A OS ":"T TARGET S;ORE SIGN 8 PHARMACY SIGN 0-2.4 L ' L GHT WE ACUITY-JUNO 34 35,38 SL412-20FT-35K-80CRI+DLDPS-96W-FPCZT+SL101P-361N+ SM1-[TOTAL RUN LENGTGH]-CL-BL+SLCUTTER SURFACE 3500K LED 96W REMOTE POWER SUPPLY LOW PROFILE SURFACE MOUNT, CLEAR LENS, BLACK FINISH 88 277 1 M2 10 18 120V RECESSED ADJUSTABLE MULTIPLE LF ILLUMINATION LI aPI G'OMS i 1 � C113 MF32CN-T-22L-8030-N-TD-D2-U-WW-CP RECESSED 3500K LED/2200 LUMEN DRIVER MATTE DIFFUSE 45 120 V 3, 26 PLP AFTER HOURS OPERATION DOOR BUZZER 12 C-2.8 DECORATIVE PENDANT ZUO 10,21 PARADISE PENDANT LED9A1930K 20A OPEN 9 120 V 20, 21 RP8 42 4 120V 8' DECO RING PENDANT OCL SL1-P1EM-96-GW-MWP-LED1-35K-UNV-72"-DMO/MOD (MOD FOR 330 LUMENS/FT) PENDANT 3500K LED 0-10V DIMMING '1,2,3, &,0,6,37,39,41 80 277 V 21 RP12 STOCKROOM S MARKET LIGHTING 2 0-4.1 12' DECO RING PENDANT OCL I,2,34„5,E>.y,,10, t :,12 SL1-P1EM-144-GW-MWP-LED1-35K-UNV-72"-DMO/MOD (MOD FOR 330 LUMENS/FT) PENDANT 3500K LED 0-10V DIMMING PARKING UGH' .G 115 277 V 21 S5L 10 11 120V MIRROR LIGHT BARTCO PERGOLA LIGHTING BLT 205 45 35 25 SM SL SURFACE 3500K LED DRIVER FROSTED ACRYLIC 32 120 V 21 SP3B CANOPY LIGHTING 5 0-5 3 6" PENDANT LINEAR LED ACUITY -MARK 15 S6LD 8FT CSQ 900LMF 35 EOHN MVOLT WHT IPS PENDANT 3500K LED DRIVER POLYCARBONATE LENS 64 277 V 1 SP3C 7,9 5 120V 6" PENDANT LINEAR LED ACUITY -MARK EMPLOYEE PARKING S6LD 12FT CSQ 900LMF 35 EOHN MVOLT WHT IPS PENDANT 3500K LED DRIVER POLYCARBONATE LENS 96 277 V 1 SP10 :Y -c .6;7,3 12 VERIFY 4' BUSSTRUT LINEAR LED ACUITY -MARK S6LDMOD 4FT FLP 80CRI 35K 400LMF 120 IPS WHT BUSSSTRUT 3500K LED DRIVER POLYCARBONATE LENS 16 120 V 1 SP30 ALL 76 120 BUSSTRUT TRACK HEAD BUSSTRUT INTEGRAL WITH PANELBOARD BR-MXH-309-U-SP12-WH BUSSTRUCK TRACK 3000K LED ELECTRONIC POLYCARBONET LENS 16 120 V 28 SR1A NIGHT STOCKING 8 4" RECESSED LINEAR LED WALL WASH ACUITY -MARK LP -7 SL4L LOP 2FT FLP TG 80CRI 35K 1000LMF WW NODIM 277 RECESSED WW - GRID 3500K LED DRIVER POLYCARBONATE LENS 20 277 V 1 SR1B HL -3 6 2 4" RECESSED LINEAR LED WALL WASH ACUITY -MARK 20A SL4L LOP 4FT FLP TG 80CRI 35K 1000LMF WW NODIM 277 RECESSED WW - GRID 3500K LED DRIVER POLYCARBONATE LENS 40 277 V 1 SR4C 4 6" RECESSED LINEAR LED DIRECT ACUITY -MARK SL6L LOP 12FT FLP FL 80CRI 35K 900LMF EOHN IPS 277 RECESSED - FLANGED 3500K LED DRIVER POLYCARBONATE LENS 96 277 V 1, 25 SR5B 108 6" RECESSED LINEAR LED DIRECT ACUITY -MARK SL6L LOP 4FT FLP TG 80CRI 35K 900LMF EOHN IPS 277 RECESSED - GRID 3500K LED DRIVER POLYCARBONATE LENS 32 277 V 1, 25 SR5C 12 6' RECESSED LINEAR LED DIRECT ACUITY -MARK SL6L LOP 8FT FLP TG 80CRI 35K 900LMF EOHN IPS 277 RECESSED - GRID 3500K LED DRIVER POLYCARBONATE LENS 32 277 V 1,25 T2-2 2 2' TRACK - WHITE ACUITY-JUNO T2WH SURFACE N/A N/A WHITE TRACK 0 120 V 21, 22, 24 T2-4 65 4' TRACK - WHITE ACUITY-JUNO T4WH SURFACE N/A N/A WHITE TRACK 0 120 V 21, 22, 24 T2-6 65 6' TRACK - WHITE ACUITY-JUNO T6WH SURFACE N/A N/A WHITE TRACK 0 120 V 21, 22, 24 T2-8 232 8' TRACK - WHITE ACUITY-JUNO T8WH SURFACE N/A N/A WHITE TRACK 0 120 V 21, 22, 24 T2-12 432 12' TRACK - WHITE ACUITY-JUNO T12WH SURFACE N/A N/A WHITE TRACK 0 120 V 21, 22, 24 T2H1 564 LED SPOT HEAD - WHITE (A&A 2.0) ACUITY-JUNO T254L G2 30K 90CRI SP WH TRACK 3000K LED DRIVER POLYCARBONATE LENS 15 120 V 19,21 T2H2 391 LED NARROW FLOOD HEAD - WHITE (A&A 2.0) ACUITY-JUNO T272L 3K HC N WH TRACK 3000K LED DRIVER POLYCARBONATE LENS 15 120 V 19,21 VL2 15 4' FOCAL DOWN FIXTURE ICON 109760 SURFACE - WALL LED DRIVER ACRYLIC DIFFUSER 50 277 V 4, 9 VL4 111 4' GONDOLA UP LIGHT FIXTURE ICON 109763 BRACKET LED DRIVER ACRYLIC DIFFUSER 30 277 V 4, 9 VL4A 6 3' GONDOLA UP LIGHT FIXTURE ICON 109771 BRACKET LED DRIVER ACRYLIC DIFFUSER 30 277 V 4, 9 VL7 14 TV WALL UP LIGHT FIXTURE 4' ICON 104134 BRACKET LED DRIVER ACRYLIC DIFFUSER 28 277 V 4, 9 Key Notes 1. Contact Acuity Lighting, TargetTeam a Acuitybrands.com, 1-800-545-6817 2. Contact On -Site Lighting, Sharon Tokkesdal, sharon@onsitelighting.com, 1-763-684-1548 3. Contact Davis & Associates, Mike Brabeck, mike.brabeck@davisassociatesinc.com, 1-952-833-3512 4. Contact Icon International Inc., 1-888-557-1122 - Rebecca Entwistle, ext. 7050, rentwistle@iconintl.net, or David Horowitz, ext. 7525, dhorowitz@iconintl.net 5. Tandem fixtures 6. Fasten directly to wall with appropriate fasteners. 7. Owner furnished flexible wiring system, installed by contractor. 8. Lamp designed for use in open fixture, safety glass or lens not required. 9. Furnished by Target with store fixture package and intsalled by electrical contractor. Mounting hardware (screws and predrilled holes) included with packages. 10. Cut reflector to length. 11. Install in accordance with manufacturer's recommendation, do not violate the UL wet location listing. 12. Fixtures furnished with lamps installed. 13. Include hager bars for fixtures. 14. Specify nominal run length as indicated on type W1 run length spec sheet. 15. Coordinate fixture mounting requirements with manufacturer; J -box, wire rating, etc. 16. Provide silver metalic finish. 17. Provide a self flange trim. 18. Electrical contractor to install 3 custom pendant light fixture per track. 19. Watts listed in schedule are per track head. 20. Electrical contractor to email quantity of light fixtures and Store T# to Contact Atmosphere Interiors, Emily.Merriman@atmosphereci.com. 21. Contact Villa Lighting, Larry Wolf, larry.wolf@villalighting .com, 1-314-633-0542 22. Provide live end feed and mounting clips with track. 23. Provide a 1A current limiter device, current limiter live end feed, and mounting clips with track. 24. Use 2', 4', 6',8' and/or 12' lengths of track as required to meet total length of track as shown on the plans. 25. Fixture must be installed prior to Gyp installation. 26. Trim ring is field paintable. 27. Contact Focus Lighting Inc, Wes Schroeder, wgs@focuscos.com, 1-952-474-9077 28. OWNER FURNISHED FIXTURE. REFER TO BUSSTRUT SHOP DRAWINGS EMS CONTACTOR SCHEDULE DEVICE NUMBER LOCATION PANEL CIRCUITS CONTROLLED NUMBER OF POLES COIL VOLTAGE CONTACT VOLTAGE CONTACT AMPS LOAD DESCRIPTION NOTES LOCAL DISC 1,1 CONT. 04,5. HL -1 1,2,9,10;17,18,25,26 10 120V 277V 2 ;`, SALES FLOOR LIGHTING EMS 0-1,2 CONT. OA13.1 HL -1 3,4,11,12,19,.20,27,20 10 120V 277V 20A SALES FLOOR LIG s`1'Il G 3 0-1.3 CONT. CAB.1 HL -1 5,0,13,14`1„22,29,30 10 120V 277V 20A SALE S FL.00 LIGHTING 094TS'061-15 C -i.4 CONT. CAB.1 10.-1 7,8,15. 6,23 24,°1,1 10 i2 V 277V 20A SALES FLOOR LIGHT! G El 0-1.5 CONT. A-,1 2 2Lo?6.'-,3,.29,30,3 32,33,35 10,2 120' 277V,` ON -STORE OPEN INA " LEC; SPECIALTY .. .v PANEL -1 i -E ALL3 €201 203L 100A, INTEGRAL WITH ElNEL�tC�%rf� ,-1.7 3^6 PANEL LP -6 LP -8 120V 208V s' 100A Ifni-; EGrf-`.: WITH PANELBOARD C-1.8 PANEL LP -6A LP -6A ALL 3 120V 208V 150A INTEGRAL WITH PANELBOARD C-1.9 CONT. OAE.1 LP -2 13 3 120V 1202' 20A YEA i CO!I_E T S PRV-5 1.11 CONT. l . CAB.1 LP -1 23,2;x`,2 7,29 12 120 V 120V 20 A ON Si•ORE OPEN If f i ERIOR CONT. i £x.B 1 0 I -.::_F-1 i 277r 2 4 ON -€'a IGH 3 FRO E t:: 56 S .`J:. RI i i3 CONY. OARIA HIE -1 .§!12 120V 277V 2. C..TED 1T TO CON CAB, 1 LOCATED 3 CON 1. CAB.2 ,.. '-moi 36,38,40,42 120V 121 20A OS ":"T TARGET S;ORE SIGN 8 PHARMACY SIGN 0-2.4 CONT. CAB.2 HL -3 34 35,38 6 120V 277V HTS ON -STORE OPEN INTERIOR Eiil JGS 0-2.6 CON .. CAB.2 HL -3 10 2 120V 277V 2i; LI aPI G'OMS i 1 � C113 0-2.7 CONT. . 046.2 LP -5 1' 2 120V 120V 204 AFTER HOURS OPERATION DOOR BUZZER C-2.8 ;,z, NY 4822 LP -9 10,21 €20\•l 120V 20A FRONT TOILETS PRV-2 & 7 C_2.9 CONT. CAB.2. HL -3 42 a 120V 277V 35A -3.1 CONT. CAB.1 :-;L-2 '1,2,3, &,0,6,37,39,41 10 120V 277V 20€t=} STOCKROOM S MARKET LIGHTING 0-4.1 :. i.: I,2,34„5,E>.y,,10, t :,12 10 12'r'}:' iJA PARKING UGH' .G 0-5,1 CO . 04:3.1 HL -2 10 2 120V 277V 20A PERGOLA LIGHTING 0-5.2 CONT. 04.13.2 HL -4 1.s 2 120V 277V 204 CANOPY LIGHTING 0-5 3 CO 's. 046.2 HI -4 15 2 1200 277V 204, PERGOLA LIGHTING 0-6.1 CONY. 0A5.2 HL -4 7,9 2 120V 277V 20A EMPLOYEE PARKING .-7,1 CONT. CAB.1 ri'.! LP -2 32,34.36.37.30.39 .. 120L 208V 20A :Y -c .6;7,3 VERIFY VERIFY_.. - 3 :2 ,. 2..a1 -. VERIFY VERIFY LP -16 ALL 3 120 208V 200 INTEGRAL WITH PANELBOARD VERIFY VERIFY LP -7 5,7 2 120V 120V 20A NIGHT STOCKING VERIFY VERIFY LP -7 1,3,11,13 4 120V 120V 20A ON -STORE OPEN VERIFY VERIFY HL -3 6 2 120V 277V 20A RESTROOM LIGHTING ASBUILT DRAWINGS INDICATES INACCURATE,MISSING OR CONFLICTING CONTACTOR INFORMATION, VERIFY NEW EMS CIRCUITING PANEL LOCATIONS AND DEVICE NUMBERS ON SITE. Electrical Dehumidification Unit (DHU) Schedule Equipment # DESCRIPTION LOCATION VOLT PH LOAD WIRE AND CONDUIT CONTROL PANEL CIRCUIT LOCAL DISC CONNECTION NOTES DHU-09 SALES ROOF 480 V 3 45311 VA SEE RISER EMS MDS 2 W/ UNIT DIRECT (axx-1) POWER MANUDCATURED INSTALLATION: EXTENDER DHU-12 SALES ROOF 480 V 3 45311 VA SEE RISER EMS MDS 5 W/ UNIT DIRECT Distribution Compressor Rack (DCR) Schedule Equipment # DESCRIPTION MARKET LOCATION WIRE AND CONDUIT 59611 VA SEE RISER CONTROL PANEL CIRCUIT LOCAL DISC W/ UNIT CONNECTION DIRECT NOTES Electrical Circulating Pump (CP) Schedule Equipment # DESCRIPTION CIRCULATION PUMP LOCATION ROOM 119 WIRE AND CONDUIT 2#12, #12G, 1/2"C CONTROL W/ UNIT PANEL CIRCUIT LOCAL DISC CONNECTION DIRECT NOTES Electrical Building Equipment (BG) Schedule Equipment # DESCRIPTION LOCATION VOLT PH LOAD WIRE AND CONDUIT CONTROL PANEL CIRCUIT LOCAL DISC CONNECTION NOTES BG -2 BALER ROOM 133 480 V 3 11634 VA 3#12, #12G, 3/4"C W/ UNIT HL -1 38,40,42 30A, NF DIRECT Electrical Transfer Fan (TF) Schedule Equipment # DESCRIPTION LOCATION TRANSFER FAN Room 153 WIRE AND CONDUIT 127 VA 1/2"C, 2#12 & 1#12G. CONTROL T -STAT PANEL CIRCUIT LOCAL DISC CONNECTION NOTES DIRECT Electrical Variable Air Volume (VAV) Schedule Equipment # DESCRIPTION LOCATION VOLT PH LOAD WIRE AND CONDUIT CONTROL PANEL CIRCUIT LOCAL DISC CONNECTION NOTES VAV-8-1 VAV BOX/HEAT COIL ROOM 105 277 V 1 3000 VA 2#10, #10G, 3/4"C EMS HL -3 20 W/ UNIT DIRECT (axx-1) POWER MANUDCATURED INSTALLATION: EXTENDER VAV-8-2 VAV BOX/HEAT COIL ROOM 105 277 V 1 3000 VA 2#10, #10G, 3/4"C EMS HL -3 22 W/ UNIT DIRECT PRE MANUFACTURED CABLE KIT SCHEDULE TYPE LENGTH ' CABLE KIT DESCRIPTION 1 25'-0" (1) 120V CABLE KIT 2 25'-0" (2) 120V CABLE KIT 3 25'-0" (1) 277V CABLE KIT & (1) 120V CABLE KIT 4 25'-0" (1) 277V CABLE KIT & (2) 120V CABLE KIT 5 25'-0" (1) 277V CABLE KIT 6 25'-0” (1) 120V QUICK FLEX CABLE KIT NOTES: A. B. C. El PP8072 POLE SYMBOL AFTER DASH DENOTES PRE MANUFACTURED CABLE KIT TYPE & NUMBERS BEFORE DASH DENOTE POWER POLE TYPE ROUTED THRU POWER POLE ARE REQUIRED TO BE IN FLEXIBLE CONDUIT. KITS ARE OWNER FURNISHED AND CONSIST OF A STARTER AND 25' FLEXIBLE WIRING EXTENDER CABLE. MANUFACTURED STARTER TO BUILDING SYSTEM JUNCTION BOX, PLUG IN EXTENDER CABLE INTO STARTER, ROUTE. FROM STARTER TO POWER POLE. REFER TO SHEET E531, DETAIL 7 FOR ADDITIONAL INSTALLATION REQUIREMENTS. POWER NUMBER LETTER CONDUCTORS CABLE HARDWIRE CABLE (axx-1) POWER MANUDCATURED INSTALLATION: EXTENDER Power Pole Schedule ELI `l Equipmen t ID Count Color Height Manufacturer Model Description OFME Item Number Target Part Number Numer Of Receptacles 120V Cable Kit 277V Cable Kit Notes (ax1) 10 GONDOLA WHITE 15' - 6" ACUITY 182NEA PP1 L186 WH AP (NO RECEPTACLES) El PP8072 0 HOLLOW PASS THRU POWER POLE USED FOR ROUTING FLEXIBLE CONDUIT & LOW VOLTAGE CABLE FROM ABOVE CEILING TO STORE FIXTURES OR EQUIPMENT (bx1) (clx) 7 12 GONDOLA WHITE LEA' A ODI ED 15 - 6" 15' - 0" ACUITY 182NEC PP1 L186 WH 1 D20A120V AP (1-20AMP El PP8073 PP:075 1 0 D & P LI HTI G 094TS'061-15 1 ' OV' L C EC LAN - R GULAR El '(mac) 12 CLEAR ANODISED 8' - 0" D & P LIGHTING 094TSP059 MAC El PP7118 0 ;A;r-i, >isMAILCII fP COMPL{ NFPA 70 - NEC, Ef DEC 0 7017 City of'Tulcwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 1 2017 ?ER')l i''TE. P TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL EXPIRES 3-09-t1 co co Q N J LL W 0 J m ftW 0 Z 12 F M Project Number T-0627 Proto: P400 Version:V13A Config: RL Drawn By RS Checked By JLS EQUIPMENT AND LIGHT FIXTURE SCHEDULE E601 11/17/2017 3:49:37 PM BULDING—°--ter\. EXTERIOR U' IL TY METERS rr>� RCUN . CON 1'" FOR TRANSF SECONDARY (2ND 18 BONDED TO BASE FRAME OF THE EDS. BOND BASE FRAME TO _PER GND STEEL 1/4,'CONDUIT PRIMARY BY DEVELOPER AND UTILITY I O 4 SETS 4"C W/44750 5) MOM CU. (X-IHW) EACH EXISTING 75'0IkVA UTILITY SF: 00.A. 4801277V:<- OW00H7 BUS WI . ONE LINE DIAGRAM SCALE: 1/4" = 1'-O" 77v.30,' "RS AND RING TRANSFORMERS LASHED BY ITY COMPANY' ./ BUS 'IN/ GROUND (3) 600A (LPS-RK) 2 SETS 3'0 W14#350 MOM CU. X. IW & 10110 (2ND EACH (2') 3P (3) SOOA (LPS-RK) 2 SETS 3"0 W/4#350 MOM CU. X1 -11-3W & .=1110 GND EACH `25;) WESTINGHOUSE, :600A; 1200A MAIN CIRCUIT A.74, GROUND FAULT PROTECTOR! 30, 1W GROUND J, D(MDS) ..'."1; 60HZ BJv '74,' `v-I"t 4,'I,, ��.� }„l..Jvj RTU -14 '41 RTU -15 (M2) 3; K) ,...NG.N.'_:. :EN RL— \MTH 30/LL CIRCUIT BREAKER 35KW 1/ A-- RTU- 60A !U- TOTAL SERVICE LOAD UTILITY LOADS PEAK KW POWER FACTOR @ PEAK KVA PEAK KVA ADD 25% of PEAK KVA per NEC + Total Base Load KVA Total Base Load KVA Net New Load KVA Total New Load KVA Total New Load Amps 727.8 181.9 Existing Service Size Amps 1600 FOR T RAN SF SECONDARY (ND .S FONnEO TO BASE FRAME OF THE f...,..,.,. BOND BASE FRAME TO 'HOER GND VIA . BU I;..;i i. _s .... ,._.._.,.. BOA 3P LPS-RK) C .306 +{ii,;J:i ')1010(2 3P 100A 3P 3P 100A 3P 548 548 160 PS -RK) (3) 70A (LPS-RK) 3) BOA LPC -RK PS -RK; (3) 70A (LPS-RK) LPS-RK) ,nn OP iv/ `3liiil"5 (LPS-CCK) 00A 3P (3) 400A PS -RK) K 1"C.304 148G 1' C.3t 1#10G 180;) \ 125A 3P 548 (3) 100A (LPS-RK) �8 ) 60A, BP 5O. 3P NE, WP NF, /DISC W/ RTU 60A. 3P NE, F P /DISC W/ RTU BOA, 3P 540 T- 8 1#2 \ / RTU -16 RTU DHU-9 RTU-10 (MIL RTU -11 Yx ( ,_. RTU -12 ',:12 DHU-12 RTU -13 (M13) 100A 3P 3W (3) 90A (LPS-RK) O /DISC W/ RTU 4 DCR-1 TRANSF SECONDARY GND, BOND TO UFER GROUND VIA BUILDING STEEL. 200A PS -BK) (3) 110A (LPS-RK) / / ; 600A.480V,2' 4W, ,...':I BUS nr \ 1i00. , i.3 ;P 2) RTU -1 RIU-2 (FROUNDING CONDUCTOR FOR TRANSF SECONDARY R f GND IS BONDED TO BASE FRAME OF ?FIE E.L.. BOND BASE FRB. „ ,.,. TO UF ER 0ND VIA BUILD NG STEEL RTU -4 Ili - GROUNDING CONDUCTOR FOR TRANSF SECONDARY GND IS BONDED TO BASE FRAME RAME OF THE Enc. BONS F BASE FR/LLMI: TO UFER GND VIA BUI! DING STEEL RTU -18 RTU -17 1.1 / ne, Z. RTU-5 I/0& 1 'TRANSFORMERC3 :' sNO.,, GROUND. '; D. L.ON D 10 UFER R GROUND VIA B,i LEEI NG STEEL. PANEL LP -6A RTU -B. R: J•, TRANSFORMER SECONDARY GROUND, BOND TO U FR GROUND VIA G STEEL.. VERIFY CONDITION OF EXISITING FEEDERS, REPLACE OR EXTEND AS N CCESARY. RTC i t- 1 & ;1OGND FAULT CURRENT AVAILABLE LESS THAN AN 2.850 AMPS 1 ./4'0.-./12 GENERAL NOTES A. MATERIALS, PRODUCTS, DEVICES, FIXTURES, FORMS OR TYPES OF CONSTRUCTION INCLUDED IN THESE SPECIFICATIONS SHALL MEET OR EXCEED THE REQUIREMENTS OF NATIONAL ELECTRICAL CODE (NEC), AMERICAN NATIONAL STANDARD INSTITUTE (ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) AND NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION (NEMA). B. MATERIALS AND EQUIPMENT SHALL BE LISTED AND APPROVED BY A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY AS CONFORMING TO THEIR STANDARDS. C. WIRE, CABLES, AND INSULATIONS SHALL CONFORM TO ICEA- NEMA AND NATIONAL ELECTRICAL CODE STANDARDS AND SPECIFICATIONS. USE NEW WIRE AND DELIVER TO THE JOB SITE IN COILS OR ON REELS. EACH COIUOR REEL SHALL HAVE A LABEL WITH THE MANUFACTURER'S NAME, TRADE NAME OF WIRE, SIZE OF WIRE AND UL LABEL. KEYNOTES # DESCRIPTION 540 INSTALL NEW OWNER FURNISHED TRANSFORMER TO BE TRAPEZE MOUNTED ABOVE NEW PANEL LOCATIONS. REFER TO DETAIL 2/E541. 547 INSTALL NEW OWNER FURNISHED PANELBOARD(S) AS SHOWN ON E355. IF SPACE IS NOT AVAILABLE TO MOUNT PANEL AS SHOWN, INSTALL AT NEAREST LOCATION WHERE 36” CLEAR SPACE CAN BE ACHIEVED. LOCATE PANEL SO THAT THE TRANSFORMER SECONDARY CONDUCTORS DO NOT EXCEED 10FT PER THE NEC. 548 FIELD VERIFY AVAILABLE SPACE. INSTALL NEW CONTRACTOR FURNISHED FUSIBLE SWITCH IN EXISTING DISTRIBUTION PANEL. CONTACT ENGINEER IF NO •I •;L •• 549 ° l..-2 REP 'C EXISTING PA EL=OA'D WTH EW AN LBOARD'' AS NOTED. RELOCATE EXISTING BRANCH CIRCUITS TO NEAREST NON CONTACTED LP PANEL AVAILABLE, VERIFY CIR UIT CAPACI , TO' LLIW FIR ' IDITION' L LO' D. TISC ' N TIS"GT, UP— X '0'RTi' H�� I' EI REMOVED. KEEP CIRCUITING FOR REUSE. REUSE EXISTING CIRCUIT FOR NEW FACTORY MOUNTED RECEPTACLE UNIT MOUNTED ON RTU OR DHU. EXTEND AND MODIFY CIRCUITING AS NEEDED. SEE 3/E521. 875 EXISTING RTU TO BE DISCONNECTED AND REPLACED WITH NEW DHU UNIT IN EXISTING AREA. REMOVE EXISTING CONDUIT AND WIRE BACK TO BOARD. REMOVE EXISTING CIRCUIT BREAKER/FUSES AND INSTALL NEW BREAKER/FUSES IN SAME LOCATION. RELABEL NAMEPLATE AS REQUIRED. EXISTING FEEDER SCHFDU PF LR CONDUCTORS (ORS FEEDER FEEDER PHASE1N GROUND Ni.; A°IPAC1 Y CONDUCTOR CONDUCTOR 0 412 A WG #12A G • 30 #IO rWC #10 ARG 40 48 AWG 410 AWG 4 OF 3P13W 3P/4VL ' S`SETS,%1NDCONDUIT CONDUIT 1/2" 1:2" 3,4" u 3/4"" 43/0 AWG 0 KCMIL 3 AL/VG 3 ./2:, BOO 3:1 C0 KC MIL 1L 800 800 2000 3000 40'00 500 KCMM':11L #1 3 tWG 500 KOMIL : 350 K: IL x.2/0 AWG — - 3 1/2'�: v F 3, 3 1/7 ,2" v�;G )O4 KC1''.'IL 500 KCMIL A 0() Kt,r? 'I», N;A 600 KCMI» N/A 3 . `2" 3 112" CONDUCTORS ALiU E`v"1'ti iJ'.. ;ACI `NDUCTI 150 200: 400 600 800 #2 AWG '- 112" ,n `t 112" GROUND 3P.'3t SETS S CONDUIT CONDUIT —avvar.®wa.�rcrnvvc.-nenv .. 44 rilsyi.71 114' __6 AVS ✓ Aits.G A'NU "r6 A•NG 41 AL/LIG #5 AWG 03/0 A VS 3 1/2" 3 1Ji2 f, xz,rnra 31/2,: , ./4:: 250 ' y • 1 L 500 CML `3 A', x 20AWO 3/0 Aie,.G 1200 o 2000 350 ./,,.MIL 500 zf✓MIL. N x/A 600 KCMI_ N A 3000 500 NCM. i 4000 600 KOMIL FEEDER SCHEDULE NOTES: FEEDERS -ED R NUM .:'IT. " _,ESiG;... ION AR _ y i• N b .t.:1tvTR%'�-K,,.0\Il�iti�.�-R 4F iri ;�t SIZE TRANSFORMER SCHEDULE NAME KVA PRIMARY SECONDARY MOUNTING REMARKS T-8 10 T-1 T-14; T-15 T-1 :AJ , r. 1; , 3 480.:3", , , ,30 200;120' 30, > 30 400V,39.:3W 430 75 480V,30,3W 16. '; ;0"f % , e 480V,30,3.11 8 . ,3e.._.. , 8 . ,3 L3,3W .208/120'. :3LLLL'LLN 2.3,120'.',3., , , 208/120V,30,4W 2081120)1.3c1,4' 12 208' 201.3o.4i+. OR LILIAL CEILING CEP NG Lam...: nOR .' A.-_ FLOOR WALL FLDO r FEEDS PANE,_ _. -; FEEDS PANEL ..."- SM �, i !ELS LP -3 FEEELS LP -4A, __. : FEEDS PANEL FEED FEEDS PANELS LP -16 FEEDS PANEL LP -1 FEEDS PA FEEDS ':N»._ 14 Era' IUI, 15 FEEDS P k W'"1�2 i.e -B ELri 06'114 REVIEWED FOE: COMPLIANCE WI3 NFPA 70- NFP,` DEC 13 2017 City of Tukwila BUILDING DIVISie RECEIVED CITY OF TUKWILA NOV 2 1 2017 ,SERMI T L.:ENT ER TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO F- CO 11.1 Project Number T-0627 Drawn By JLS Checked By TK ELECTRICAL ONE -LINE DIAGRAM E611 11/17/2017 3:49:41 PM ROOM 129 SURFACE MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 14.000 RMS 480/277 VOL T, 3 PHASE. 4 WIRE, WITH GROUND BUS 100A BUS MLO SUPPLIED FROM ATS DESCRIPTION LOAD LOAD BREAKER KVA QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION O FF1(7,,P"r 15H TI(7' SECUOTYL1G > _.. 2-'"`A %... SPARE ,7EF C_ EN -SIGNS. SPA RP SPA RE S PA S PA RE SPA PE 2. 3 R SR 20/I 20/I , 20/ . 20/1 20/1 s0. .20/22 2(711 25 0 $ y 20 24 20/1 20/1 20/1 20/7 2/ .20/1 2041 (127(77 SR Si F.7 SR ur/ (15) 0.89 STOCKROOM LIGHTING 0.3 EXIT SIGN / M'Et. ITYLI'. r f C IL' L ES COP LIGHTING SPA '27:1 Demand Load Phase A Phase B Phase C Total Average *Spares not included KVA AMPS 4.0 14.4 5.8 20.8 7.8 28.0 17.5 21.0 Type KVA Factor KVA L 14.0 x 1.2... R 0.0 x 0.5 = PN 0.0 x 1 = PW 0.0 x 1 = MN 0.0 x 1 = MNI 0.0 x 1 = MS 0.0 x 1 = MW 0.0 x 1 = KT 0.0 x 0.6... Total 14.0 17.5 0.0 *100% of 1st 10kva, plus 50% of remainder. 0.0 0.0 0.0 0.0 0.0 0.0 14.0 Total Connected KVA 0.0 17.5 Total Demand KVA 17.5 21.0 Total Demand Amps T-0627 10/19/17 ROOM 155 SURFACE MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 18,000 RMS 480/277 VOL T, 3 PHASE, 4 WIRE, WITH GROUND BUS 200 A BUS MLO SUPPLIED FROM HP -2 DESCRIPTION LOAD LOAD BREAKER KVA QTY TYPE AMP/POLE # BREAKER LOAD • LOAD DESCRIPTION 1°) FITTING ROOM DWN LITES SPA RE SP/ d /'n%n.... WH -1 i,' 6,/ I. / / 0.46 // 4 4 4 PVI 20/3 pp/. ,_, L _✓ r,3 (1) PN PN PN 1 SF 5,1=1! 2x/3 19 2. 23 12 6 20/1 227? 262/ 1/7 2017 , 2 r'! 26 20/1 .2.i0/1 30 20/1 3, 20/1 ;ate; . 20/1 30 20/ 20/7 20/1 42 2071 MW /1/1W //i I/i PN PN re SR L L SR Sr 0.5 OFFICE LIGHTING 1 OFFICE LIGHTING (31) 1 OFFICE/RESTROOM LIGHTING SPARE S PARE i 3: (FA 3 - 0, 5 G'.5 3 VAV-8-1 3 VAV-8-2 1,vi RHA;II MA (.71/ I /R1j;'/C%O t '.tWH --I rvt: , O PAR 0.28 RING LIGHTS BEAUTY 1.44 PERIMETER VALANCE LGT O SPARE O SPARE Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 14.4 17.0 13.4 44.7 52.0 61.2 48.3 53.8 Type KVA Factor KVA L 8.2 x 1.2... R 1.0 x 0.5 = PN 29.0 x 1 = PW 3.0 x 1 = MN 0.0 x1= MNI 0.0 x 1 = MS 0.0 x 1 = MW 1.5 x 1 = KT 0.0 x 0.6... Total 42.7 10.2 1.0 *100% of 1st 10kva, plus 50% of remainder. 29.0 3.0 0.0 0.0 0.0 1.5 42.7 Total Connected KVA 0.0 44.7 Total Demand KVA 44.7 53.8 Total Demand Amps T-0627 11/1/17 ROOM 129 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 100A BUS 100A MOB SUPPLIED FROM T-7 EQUIP WITH FEED THRU LUGS DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION Y�. • ARS {-0 21 t,, ..y<.T SPARE 571-)?:', 2 /s LI E Demand Load Phase A Phase B Phase C Total Average *Spares not included KVA AMPS 2.2 18.6 4.1 34.0 2.2 18.3 8.5 23.6 Type KVA Factor KVA L 0.0 x 1.2... R 7.9 x 0.5 = PN 0.6 x 1 = PW 0.0 x 1 = MN 0.0 x 1 = MNI 0.0 x1 = MS 0.0 x 1 = MW 0.0 x 1 = KT 0.0 x 0.6... Total 8.5 0.0 7.9 *100% of 1st 10kva, plus 50% of remainder. 0.6 0.0 0.0 0.0 0.0 0.0 8.5 Total Connected KVA 0.0 8.5 Total Demand KVA 8.5 23.6 Total Demand Amps T-0627 10/19/17 1 ROOM 129 SURFACE MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 25,000 RMS 480/277 VOL T, 3 PHASE 4 WIRE, WITH GROUND BUS 225A BUS MLO SUPPLIED FROM HP -1 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION OR US £'.Ids°O ..fin i r Gti. [y SALES FLOOR � lF , _... r,, c _ s<xv w.-. SALES LO OR r/ .".. _ ING r SALES F1 FLOOR / w , 1 nO 8A! RS.. L,)>.O6.,_£� SALES o16ULIGHTING ,...,F EL'f.,I; SA! ES FLOOR _! H i G SA! FS FLOOR! IGHE SALES FLOOR LIGHT SALES FLOO ,- LIGHT' SPARE. R 2IC',s "' 3.7 7 3,7 3,7 1 0 0.6 SR 2011 20/1 LU/ , 20/1 20/1 2011 90/1 2011 2//i 2011 20/1 2011 2011 2011 20/1 >011 25 22 1 3' 35, C r2 26 28 38 a1 20/1 20/1 2,011 2011 2011 2011 . 2011 "a tart N r 20/1 20/3 PW PW PW ,l SALES F yr S SALES FLOOR R S 6 SALES ' 2.8 SALEM" LL.J,i.,R L.4Si 3 S . 3,7 SAO .,./ My . LIGHTING, 2,8 SALES . ,....L:.jz e ,.,/'L/ L 3,6 SA!!�, FLOOR L0O/G 3.6 3.7 2.b 2.5 =.4 SA` FS F LOR ,I L101- Fl.00R LIGHTING ING <L£ .r". C 3.88 BG -2 3.88 3.88 Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 47.0 44.0 45.1 136.1 169.7 158.9 162.9 163.8 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 99.6 0.0 0.0 11.6 0.0 0.0 0.0 0.0 0.0 111.2 x 1.2... x 0.5 = x1= x1= x1= x1= x1= x1= x 0.6... 124.5 0.0 *100% of 1st 10kva, plus 50% of remainder. 0.0 11.6 0.0 0.0 0.0 0.0 111.2 Total Connected KVA 0.0 136.1 Total Demand KVA 136.1 163.8 Total Demand Amps T-0627 10/19/17 ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10.000 RMS 120/208 VOL T, 3 PHASE. 4 WIRE, WITH GROUND BUS 100,4 BUS 100A MAIN BREAKER SUPPLIED FROM TE -1 HLO - HAND LOCK ON DEV/CE DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION SPARE CASH REGISTERS CASH REGISTERS CASH REGISTERS 1.0 1.0 1.0 R R R R 2011 2011 1 GUEST SERVICE REG GUEST SERVICE REG PHA ,.. ` ''?'' C<;REG ELECTRONICS CASH REG SP/11'7's: CCTV t S✓ 7 2 �'iJ� 3 f �iai SPARy„ SPAR" CASH REG 169 PHA 'i RC!'/'//^��'££i Y 1-7 `r3i T..... TEL P Pt� 6..%1k.I:. sWITC 'i``', s L OI / ,7 /3.00/7 Ly,!I/,.INC/'O',' COILING r"/ 0.9 0.9 0.5 0 0 0 4 0. 0, 0 02 0. 5 j.0 ,1 R R (3) R SR PA' /; < 20/1 20/1 ..3 .4 4, 0: / / 2/ ' L,i 20I 29 20/'1 20/1 20/1 1 20/1 _20/1 20/1 31 '35 101 12 14 '16 1 2mm 'S.� 1^ 20/1 20/1 20/72 20/7 20/1 20/ 20/1 211 20/7" R R R P}?i1 ry,rl P i 5R -" U 7 SR 1.0 CASH REGISTERS 1.0 CASH REGISTERS 1.0 CASH REGISTERS 1.0 SCO REGISTERS ;, 6s/1S POI. vE I? i. f C PARE 3, 7 UPS SPA RE 0,Cwi fY✓% /OOMS ; 04 O6 S 2R ? 01 S[_ ARE O 0 SPA RE r-3 32 4 42 2011 20/1 20/1 .9:'1 f;011 20// R R 1? R R 0.0 0.0 0.0 0.0 f' SPARE SPARE ROOM SPARE SPARE SPA RE CK Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 9.7 6.3 6.1 22.1 81.0 52.2 50.8 61.3 Type KVA Factor KVA L 0.0 x 1.2... R 14.1 x 0.5 = PN 6.7 x 1 = PW 0.0 x 1 = MN 3.3 x 1 = MNI 0.0 x 1 = MS 0.0 x 1 = MW 0.0 x 1 = KT 0.0 x 0.6... Total 24.1 0.0 12.1 *100% of 1st 10kva, plus 50% of remainder. 6.7 0.0 3.3 0.0 0.0 0.0 24.1 Total Connected KVA 0.0 22.1 Total Demand KVA 22.1 61.3 Total Demand Amps T-0627 11/1/17 ROOM 129 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RA T1NG (IER) - 10,000 RMS 120/208 VOLT, 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS 125A MOC SUPPLIED FROM T-2 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION ..,;*11•1/16‘,K. . /Ss✓.? .,.., y..? v f 277/;L..E It !.,.Tri:.., 1, *r/ APPLE 24 HOUR POWER SPARE 0M123,125) wf ,r� , x <... ., ... -L701-1 .•.. O , f '.., L / f....,'.... 0.54 0 (3) R SR 20'7 20 . Or 1 20/1 20/1 20/1 2f rf I 25 2 / • 18 22 24 20/ 7 _1 ... 17N 29/7 20/7 26/ ...J' . 217/11 T ,,29/2 G;'i ( ate.. , .._ < ..✓ l R i �- ✓I. 0.5 92 T,2008 51771,://(10' R (3) 0.54 APPLE 24 HOUR POWER ... !l/ 9.'. 2r)'2 ...< v 2tf' / 20/1 PA/ 1.9 P, ; U-5 R1/C wY t u✓L,:..n. A117 1,717 Y E f riA T7177 171? / f27/671,/,11 -Al Demand Load KVA AMPS Phase A 10.2 85.3 Phase B 9.8 81.7 Phase C 9.9 82.8 Total 30.0 Average 83.3 *Spares not included Type KVA Factor KVA L 0.0 x 1.2... R 8.8 x 0.5 = PN 6.2 x 1 = PW 9.0 x1 = MN 5.4 x1 = MNI 0.0 x 1 = MS 0.0 x 1 = MW 0.6 x1 = KT 0.0 x 0.6... Total 30.0 0.0 8.8 *100% of 1st 10kva, plus 50% of remainder. 6.2 9.0 5.4 0.0 0.0 0.6 30.0 Total Connected KVA 0.0 30.0 Total Demand KVA 30.0 83.3 Total Demand Amps T-0627 10/19/17 1 1 ROOM 129 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (/ER) - 14,000 RMS 480/277 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS MLO SUPPLIED FROM HP -1 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION <. TOCX t LIGHTING • f l P PW P ,'l/ p.' 7 1i RING LIGHTS A&A SPARE SPARE PERIMETER VALANCE LGT PERIMETER VALANCE LGT S TO CIV? 00M L IG , HT/ STOCKROOM LIGHT/NG 0 1.67 0.57 L SR SR L L 2C,171 20/. 20/1 20// /} 40/1 20;1 20/ 29/1 20' 20/ 1 20/1 20/1 20/ / 2077 20/ l _„.e !t 2723 x n3 4" 31 A 33 22 24. nh 32 36 38 L 20/1 20/1 20/ I n/ iy; j 20/1 0/" <, L/; t .20/1 l 4/2/1 MNI'! L L L ,F "z/ MARKING f-3RiiING L,'G< I T1, , 3.8 Y1A11 KING /,/CH/T/ G 1.6 MARKING, STOCK, WALK-IN .272 SA C I 0-7 COMIIGH • I ::r,` I_ r 1. / ` KINI c ./-/ 3 CO ' ": i ; } 0 VA V- 12'11 (15) 0.59 FREEZER/COOLER LIGHTING 0.63 PERIMETER VALANCE LGT 0.76 PERIMETER VALANCE LGT 1.1 INVES TIGA TIO/ s1 O TR = TG 111/V EST/ GA T'ON C TR L T G 1,2 li>/VEST'GATION L;7i TO 7,5 VI l-' 1//117-17-3 ;':A V-1 7-4 Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 25.8 93.3 39.4 142.4 35.3 127.3 100.5 121.0 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 48.9 x 1.2... 61.1 0.0 x 0.5 = 0.0 *100% of 1st 10kva, plus 50% of remainder. 0.0 x 1 = 0.0 28.0 x 1 = 28.0 0.0 x 1 = 0.0 11.4 x1= 11.4 0.0 x 1 = 0.0 0.0 x 1 = 0.0 88.3 0.0 x 0.6... 0.0 100.5 88.3 100.5 121.0 Total Connected KVA Total Demand KVA Total Demand Amps T-0627 11/17 ROOM 129 SURFACE MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOLT 3 PHASE, 4 WIRE. WITH GROUND BUS 100A BUS 80,4 MCC SUPPLIED FROM T-1 EQUIP WITH 100 AMP. 3 POLE CONTACTOR ON MAIN BUS DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION SPARE TOYS POWER POLES TOYS P C £'V...<?SOLE/% TO ,e TO YS POWER POLES Sf a%'1 Pi LI , y. SMA} r APPLIANCE SEASON Ca FLOORCARE FLOORCARE FLOORCARE SPARE A&A TRACK SALES FLOOR TRACK KITCHEN CORNER HSW TRACK KITCHEN CORNER HSW 1 n 0 0.4 0.4 0.4 0.6 / /" (.J.6 0. 6„ 0.72 0.54 0.18 0 1.2 1.2 1.2 (4) (3) (1) SR F7 Y� R R R f L L L 0 20/1 2 al l 2;/1 ,20/1 204 25.-2/1 f ;20/I 20/7 20/.1 20'1 2a/I 20/1 , 2 A 0 12 18 u 2�f 20/1 1 20/1 20/1 20/1 ,' R R (2) R (6) 02 0,2 ,F, a / SEASONAL SE, SO i1f L SEf SO/ 1 SEASONAL SEA C"", moi✓.'F.lf ry ��ItiSt. tl./'If SEAS Of'uA _ SPA RE RECEP72 C"LP POWER POLE POWER r=OL:� POWER POLES S POw I= PO L -S F0 % PI ` 1r 5t8 t c"/"` /:7-i POI_ 1.08 CONNECTED HOME Demand Load KVA AMPS Phase A 5.1 42.4 Phase B 5.5 46.2 Phase C 5.7 47.7 Total 16.4 Average 45.4 *Spares not included Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 4.8 x 1.2... 10.7 x 0.5 = 0.0 x 1 = 0.0 x 1 = 0.0 x 1 = 0.0 x 1 = 0.0 x 1 = 0.0 x 1 = 0.0 x 0.6... 15.5 6.0 10.4 *100% of 1st 10kva, plus 50% of remainder. 0.0 0.0 0.0 0.0 0.0 0.0 15.5 0.0 16.4 16.4 45.4 Total Connected KVA Total Demand KVA Total Demand Amps T-0627 10/19 ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10.000 RMS 120'208 VOL T, 3 PHASE. 4 WIRE.,WITH GROUND BUS 2254 BUS MLO SUPPLIED FROM T-1 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION /-, CCER-1A E / r� CASH REG. CONV/BELT RCPT CASH REG. CONV/BELT RCPT 0.7 0.7 SPR SPARE SPARE SPARE COOLERS COOLERS COOLERS SCO COOLER TOUCHFREE URINALS & TOILETS 0.7 (10) I INGR•O B E_. P' -S 1.36 ( R R R R R R R R R R R R R R 20/1 202/ .2077 30 .36 47) • 217/ i 217/1 2011 20/1 20/1 0.7 CASH REG. CONV/BELT RCPT 0.7 CASH REG. CONV/BELT RCPT 0.7 CASH REG. CONV/BELT RCPT 0 SPARE 0 SPARE E CLO/ 0 SPARE 0 SPARE 1 COOLERS 1 COOLERS 1 COOLERS 0.2 MART CART Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 5.7 6.2 6.5 18.4 47.7 52.0 53.9 51.2 Type KVA Factor KVA Total 21.9 0.0 13.4 *100% of 1st 10kva, plus 50% of remainder. 2.0 3.0 0.0 0.0 0.0 0.0 21.9 Total Connected KVA 0.0 18.4 Total Demand KVA 18.4 51.2 Total Demand Amps T-0627 10/19/17 GENERAL NOTES A. INSTALL OWNER FURNISHED CIRCUIT BREAKER HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. PANELBOARD LOAD LEGEND L - LIGHTING PN - POWER NON -SEASONAL PW - POWER WINTER MN - MOTORS NON -SEASONAL MNI - MOTORS NON -SEASONAL INTERMITTENT MS - MOTORS SUMMER MW - MOTORS WINTER KT - KITCHEN - SPARE - SPACE REVIEWED [rur, DEC 1 3 2017 City of Tukwiii BUILDING DIV0',.)040 RECEIVED NOV 2 1 2017 PANELBOARD BREAKER TYPE LEGEND GFCI - GFCI BREAKER TIE - PROVIDE MECHANICAL TIE FOR SPLIT WIRE RECEPTACLE ELvi 004 TARGET® 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/09/2017 7 DCN 1016151 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO CO LU Project Number T-0627 Proto:P400 Config:RL Drawn By RS Checked By TK PANELBOARD SCHEDULES E621 11/17/2017 3:49:50 PM ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10.000 RMS 120/208 VOL T, 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS MLO SUPPLIED FROM LP -3 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION CONF 164/163 LPC 149 OFFICE RECEPTACLE ETL&TL 162 OFFICE RECEPTACLE ETL&TL 162 OFT-91CF 802/ER O1-70E75/T TOL B7; 34N/773/7, 208 ).-4501.JF<F-\( OFFICE ETL&TL 162 o/ -E/.9 ,350)( R IS I-71-27: 0 ETL&TL 162 ETL&TL 162 ETL&TL 162 STL OFFICE RM160 REFRIGERATOR REFRIGERATOR 1.1 0.9 0.9 0.7 0.5 0.5 7, 1.8 0.4 28 0, 8 0.4 1.1 0.4 0.4 1.2 1.2 R R • 21.7; R 20/I R 2077 287 2022 f 2 2E9/1 Fl 30/ • 2741 i(r'N 201 • 20/ R R 2(2/ R 20/ R 20/1 R 1 7 2119 25 27 2 9 2,7 39 51 C 3 1212 :2;7 r 28 30 73 36 0 42 23/1 20/1 20/ 207 20/ 90/ 20/, 20/: 20/ 20/ _0/ 3,07 <20/ 20/1 20/ I .27'1 20i R R R I"? R R FA/ R R pAi 0.5 OFFICE RCPT 1.1 OFFICE USB 0.2 MICROWAVE 0.2 VENDING 7.4 iv) -2.5` 0.2 VENDING 32 0.4 If 0. 2 6 CA 31-1 OF PL (3 S TrVP 1.1 OFFICE CRT'S 0, 4 PRCP R 708 0,4 RCPT RM 0S a 0 C.7721 25 CC Ti2 (VON/TOT! 0.4 ETL&TL 162 0.4 ETL&TL 162 4.5- Sl...11 CI( 3AR FIRE I%70 /24 /1/1-48 (22-2) TR 0001- 6/7 Demand Load KVA AMPS Phase A 7.0 57.9 Phase B 10.4 87.0 Phase C 7.9 65.6 Total 25.3 Average 70.2 *Spares not included Type KVA Factor KVA L R PN PW MN MNI MS MW Kr Total 0.0 x 1.2... 0.0 21.5 x 0.5 = 15.8 *100% of 1st 10kva, plus 50% of remainder. 3.8 x 1 = 3.8 0.0 x 1 = 0.0 5.7 x 1 = 5.7 0.0 x 1 = 0.0 0.0 x1 = 0.0 0.0 x 1 = 0.0 31.0 Total Connected KVA 0.0 x 0.6... 0.0 25.3 Total Demand KVA 31.0 25.3 70.2 Total Demand Amps T-0627 10/19/17 ROOM 128 FLUSH MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (/ER) - 10,000 RMS 120/208 VOL T, 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS 150A MAIN BREAKER SUPPLIED FROM T-5 EQUIP WITH FEED THRU LUGS DESCRIPTION LOAD KVA QTY LOAD BREAKER TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION MARKET TRACK HEADS MARKET TRACK HEADS MARKET BUSSTRUT LINEARS MARKET BUSSTRUT LINEARS ADULT BEVERAGE LIGHTING ADULT BEVERAGE LIGHTING SPARE SPARE SPARE 1.71 1.71 0.1 0.1 (38) (38) (6) (6) L L L 0 0 0 R R R R R R PN PN PN PN 0 SPARE 0 SPARE 0 SPARE 0 SPARE 0 SPARE 0 SPARE 0 SPARE Demand Load KVA AMPS Phase A 6.3 52.6 Phase 13 6.3 52.8 Phase C 3.2 26.5 Total 15.8 Average 44.0 *Spares not included Type KVA Factor KVA L PN PW MN MNI MS MW Kr Total 7.2 x 1.2... 9.0 4.2 x 0.5 = 4.2 *100% of 1st 10kva, plus 50% of remainder. 1.4 x 1 = 1.4 1.2 x1 = 1.2 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 14.0 Total Connected KVA 0.0 x 0.6... 0.0 15.8 Total Demand KVA 14.0 15.8 44.0 Total Demand Amps T-0627 10/19/17 ROOM 125 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOL T, 3 PHASE, 4 WIRE, WITH GROUND BUS 100A BUS MLO SUPPLIED FROM T-2 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION , . SPARE 0 '1 PN PN PN PN PN • PN PN PN PN PN PN PN .52 0.1 F01 FANS 0.1 F02 FANS 0.1 F03 FANS 0.1 F04 FANS 0.1 F05 FANS 0.1 F06 FANS 0.1 F07 FANS 0.1 F08 FANS 0.1 F09 FANS 0.1 F10 FANS 0.1 F11 FANS 0.1 F12 FANS Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 2.3 4.5 3.1 10.0 19.5 37.6 25.8 27.7 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 0.0 x 1.2... 0.0 1.0 x 0.5 = 1.0 *100% of 1st 10kva, plus 50% of remainder. 9.0 x 1 = 9.0 0.0 x 1 = 0.0 0.0 x1 = 0.0 0.0 x1 = 0.0 0.0 x1 = 0.0 0.0 x 1 = 0.0 10.0 Total Connected KVA 0.0 x 0.6... 0.0 10.0 Total Demand KVA 10.0 10.0 27.7 Total Demand Amps T-0627 10/19 ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RA4S 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 100 A BUS 100A MCB SUPPLIED FROM MAIN SWITCH GEAR DESCRIPTION LOAD KVA QTY LOAD BREAKER TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION CLUB WEDD CLUB WEDD ATM TAKE-;UIL71›/IBE1? /.215,;PL2I,i P1137/C IC PI--/ONFSRCP YT KOSK0 MEI 7'01.2214VJA /V/ TOR DOOR ,I.3LIZZR 0.2 0.2 0.4 0 22 0 022 0 CL d wsoo 50/1A ric IT; 82 )7li33E/- 784 1<708 GUEST SERV STORAGE RCPT 0.18 KPM PHOTO EQUIP 0.18 KPM PHOTO EQUIP 0.18 MENS HAND DRYER MENS HAND DRYER SPARE £17 5100774 0.7 0.7 0.7 0.7 0,2 R R 7.2 Riv SR R R R R R SR PA' 2071 20/1 26/7 7 .272/i ;20i/. 12 20/1 20/1 17 .25V1 20/1 21 20/1 23 ;23/ 2'5 20/i A • 27 20/7 31 33 37 39 20/I 41 20/1 Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 6.6 7.5 7.0 21.2 55.0 62.9 58.5 58.8 Type L R PN PW MN MNI MS MW Kr Total U' UD 2 .1 10 I 2 16 I 20 22 24 /2 2Z3 30 422 34 36 38 40 42 20/1 20/1 20/ 20/1 20/1 2r,vi 2.7 PTV P,A1 , ply R R R SR SR (26L L WO T CENTER 0 .8 SA ES FL 0,0s4.? RCPT. 0 8 SALES FL OCR /?C1-' 92 ,AIA .90/i/v'S PLit17--COOLER 015 800/5135 015 COOLERS 1. .4 FREEZER 1. 4 FRC:P-7ER 14 FREEZER 1.4 FREEZER (1) 0.7 WOMENS HAND DRYER 0.7 (1) 0.7 WOMENS HAND DRYER 0.7 (1) 0.36 (1) 0.6 (1) 0.36 SPA RE 817,41(-71S SOUTH BULLSEYE SIGN PHA F-71(14. CY SIGN ENTR. BULLSEYE SIGN EAST BULLSEYE SIGN KVA Factor KVA 2.3 x 1.2... 2.9 12.1 x 0.5 = 11.1 *100% of 1st 10kva, plus 50% of remainder. 7.2 x 1 = 7.2 0.0 x1 = 0.0 0.0 x 1 = 0.0 0.0 x1 = 0.0 0.0 x1 = 0.0 0.0 x 1 = 0.0 21.7 Total Connected KVA 0.0 x 0.6... 0.0 21.2 Total Demand KVA 21.7 21.2 58.8 Total Demand Amps T-0627 10/19/17 ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT F?AT1NG (IER) - 10,000 RMS 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS 200A MCB SUPPLIED FROM T-8 DESCRIPTION LOAD KVA LOAD BREAKER TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION ETL-HR 161 PRINTER TRAINING RM 158 TRAINING RM 158 TV MICROWAVE MICROWAVE MICROWAVE MICROWAVE MICROWAVE LOUNGE 157 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.0 R R R R R R R R R (2) 0.4 TSC DESK 152 R (2) • 0.4 TSC DESK 152 R (1) 1.0 TSC COPIER 1 ...0 2 0.2 CASH OF IC 104 R 0.7 CASH OFFICE 104 R 0.9 CASH OFFICE 104 1,1 T 1 Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 13.0 10.7 12.4 36.1 108.3 89.0 103.5 100.3 Type L R PN PW MN MNI MS MW Kr Total KVA Factor KVA 0.0 x 1.2... 0.0 23.4 x 0.5 = 16.7 10.0 x 1 = 10.0 0.0 x 1 = 0.0 9.4 x 1 = 9.4 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 0.6... 0.0 42.8 36.1 *100% of 1st 10kva, plus 50% of remainder. 42.8 36.1 100.3 Total Connected KVA Total Demand KVA Total Demand Amps T-0627 10/19/17 1 ROOM 125 SURFACE MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS 175A MCB SUPPLIED FROM T-16 DESCRIPTION LOAD KVA QTY LOAD BREAKER TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION A08,A09 LIGHTS B01 B03 REFR LIGHTS B02 REFR LIGHTS B04 B05 REFR LIGHTS c;' .0 5 ,7,7 P;.-7;17`7 L;(3* I TE B08 B09 B10 REFR LIGHTS A 13 61 41.1-205 /0/0 I .1G ti A01-A,B,C FANS A02 FR2277 N 403 FreZ A6:7 FR ZR A;S q 0 5 I-7737 FANS A0 ;5-41N3 27:28 I74A' SPARE A08 FRZR FANS A09 FRZR FANS 0,7 0.2 0.7 1.1 0.7 1.0 1.1 0.0 0.5 0.6 L L L L L L PN TN L PN PN 212;1 21.)71 20( 25 :55 29(1 :2671 20/ PN PN PN PN pAt PN PN 42 PA/ L L SR SR 0.2 B01 B03 REFR FANS 0.3 B02 REFR FANS 0.4 B04 B05 REFR FANS 015 8/06297 REFR (/24//s 7 3081309 2EF-7 1.7 B10 FANS 6.0 .43024503 L2,232-4,-95; 402 .':R75R L hz: F1711 04' .0 ,5:1,52R1:217 :5 FR ZI? 1-1777 7 0.3 A08 FRZR DR HTR 0.4 A09 FRZR DR HTR '1594408,--I, [1» 0.8 F01 -F06 LIGHTS 0.8 F07 -F12 LIGHTS 0.0 SPARE 0.0 SPARE Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 9.7 11.3 12.8 33.7 80.5 94.1 106.5 93.7 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 9.1 0.0 22.4 0.0 0.0 0.0 0.0 0.0 0.0 31.5 x 1.2... x 0.5 = x 1 = x 1 = x1 x 1 = x 1 = x 1 = x 0.6... 11.4 0.0 *100% of 1st 10kva, plus 50% of remainder. 22.4 0.0 0.0 0.0 0.0 0.0 0.0 33.7 31.5 33.7 93.7 Total Connected KVA Total Demand KVA Total Demand Amps T-0627 10/19 ROOM 155 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 100A BUS 100 A4C8 SUPPLIED FROM T-6 EQUIP WITH 10 0 AMP. 3 POLE CONTACTOR ON MAIN BUS 1 DESCRIPTION BEAUTY DSPLY RCPTS PROMO(FUTURE) L4.51--). A 'Y LOAD LOAD BREAKER E BREAKER LOAD LOAD # AMP/POLE BEAUTY VALANCE PLUGSTRIP PROMO(FUTURE) PROMO(FUTURE) 0.54 0.54 0 0.54 0.54 0 BEAUTY VALANCE PLUGSTRIP 1.08 1.08 BEAUTY VALANCE PLUGSTRIP 1.08 A E SPARE .0: S 0 R 20/2 R 20/ R 20/2 R R 20;1 R 20/I R 20/2 R R 20/2 R P PW 20/1 •; 9 15 1 e 21 23 5;5 27 29 4', 21)/1 4 20/I .20/7 14, 17 20 22 24 25 28 24 20'1 20/2 R 20/2 20/1 •••• ••••• •••••• .•••• Ann L L • DESCRIPTION a AN. Anilm• MM. AO., All••• 3.41111. 0.9 GREETING CARD DISPLAY LTG 0.9 GREETING CARD VALANCE LTG 0.9 GREETING CARD PP L (1,) ,0.3, RE JR•O,. M RR R IG T Sfr 1 9.4 13 RAI,1195,'.7) 171,3 /217'' 0.3 1 ANT 80:112207A TO PP 1.08 BEAUTY VALANCE PLUGSTRIP R 1.08 S AR 1.08 BEAUTY VALANCE PLUGSTRIP 1.08 1.08 BEAUTY VALANCE PLUGSTRIP 1.08 0 SPARE Demand Load KVA AMPS Phase A 6.1 51.2 Phase B 6.4 53.6 Phase C 4.7 39.0 Total 17.3 Average 47.9 *Spares not included Type KVA Factor KVA L 3.3 x 1.2... 4.1 R 14.3 x 0.5 = 12.1 PN 0.0 x 1 = 0.0 PW 0.0 x 1 = 0.0 MN 1.0 x 1 = 1.0 MNI 0.0 x 1 = 0.0 MS 0.0 x 1 = 0.0 MW 0.0 x 1 = 0.0 Kr 0.0 x 0.6... 0.0 Total 18.6 17.3 *100% of 1st 10kva, plus 50% of remainder. 18.6 17.3 47.9 Total Connected KVA Total Demand KVA Total Demand Amps T-0627 10/19/17 ROOM 120 FLUSH MOUNT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS MLO SUPPLIED FROM T-4 HLO HAND LOCK OFF DEVICE LOAD BREAKER BREAKER SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 231/ 2,2/7 332 20/1 20/1 2071 2071 20/1 20/1 20/1 f S(3 2a/7" Kr 2071 KT 20/7 KT 20/i KT ,.•20/2 Kr Kr 2a/-1 KT 30/7 Kr 20/1 Kr .20/1 KT 20/1 Kr 201 Kr 20/2 Kr Kr Kr 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 „.„ 2ox Kr . ..„ . , 0.0 SPARE Phase A Phase B Phase C Total Average *Spares not included KVA Factor 0.0 x 1.2... 0.0 x 0.5 = 0.1 x 1 = 0.0 x1 = 0.0 x 1 = 0.0 x1 = 0.0 x1 = 0.0 x 1 = 0.0 x 0.6... 0.1 0_0 0.0 *100% of 1st 10kva, plus 50% of remainder. 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Total Connected KVA Total Demand KVA Total Demand Amps REAR EDC 138 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CITCU1T CURRENT RATING (IER) - 10,000 F?/VS 120/208 VOLT 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS MCB 175A SUPPLIED FROM T-13 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP/POLE BREAKER LOAD LOAD AMP/POLE TYPE QTY KVA DESCRIPTION ITV CCI'. 7/1 1222 If I:1/1 ,) 12,„`..? 3:sPA ENTERTAINMENT DSPLY RCPTS CONTENT PLAYERS SPARE 0.36 0.18 0 Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 14.7 13.7 17.6 46.1 122.8 114.5 146.8 128.0 SP /73 );1,"/ R SR cB 1 C4. 24/ '17 15 15 23 21 25 C26 27 \ 28 29 33 3 A 32 2017 23 3 54 35 C 317 20/1 37 I\ 38 20/ 3 40 20/I C, 42 21); 1577 2041 7;522 Type KVA Factor 0.0 4.9 PN 41.0 PW 0.0 MN 0.0 MNI 0.0 MS 0.0 MW 0.0 KT 0.3 Total 46.2 x 1.2... x 0.5 = x 1 = x 1 = x 1 = x 1 = x 1 = x 1 = x 0.6... (2(.7IL 8:1 R 9:92 1.31.44P CO/L, FAA/ PROT :/87 FRz2? (505 171/ 015542- C;(0027E-127; 0 I. C 1,8 1.08 ELECTRONICS DSPLY RCPTS 1.08 ELECTRONICS DSPLY RCPTS KVA 0.0 4.9 *100% of 1st 10kva, plus 50% of remainder. 41.0 0.0 0.0 0.0 0.0 0.0 46.2 Total Connected KVA 0.2 46.1 Total Demand KVA 46.1 128.0 Total Demand Amps REVIEWED FOli COMPLIANCE WITH NFPA - NEC DEC " 3 2017 GENERAL NOTES A. INSTALL OWNER FURNISHED CIRCUIT BREAKER HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTI WIRE BRANCH CIRCUITS PER NEC 210.4. PANELBOARD LOAD LEGEND R -RECEPTACLE L - LIGHTING PN - POWER NON -SEASONAL PW - POWER WINTER MN - MOTORS NON -SEASONAL MNI - MOTORS NON -SEASONAL INTERMITTENT MS - MOTORS SUMMER MW - MOTORS WINTER KT -KITCHEN - SPARE - SPACE ELI City of Tukwila BUILDINGDIVISIr RECEIVED CITY OF TUKWILA NOV 2 1 2017 "ERMIT CENTER PANELBOARD BREAKER TYPE LEGEND GFCI - GFCI BREAKER TIE - PROVIDE MECHANICAL TIE FOR SPLIT WIRE RECEPTACLE 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com Date No. Description 09/29/2017 PERMIT ISSUE 10/16/2017 1 DCN 1014990 11/06/2017 3 DCN 1015786 11/14/2017 BID SET 11/21/2017 PERMIT RESUBMITTAL SOUTHCENTER, WA CO CO CO VC; Project Number T-0627 Proto:P400 Version:V13A Config:RL Drawn By RS Checked By TK PAN ELBOARD SCHEDULES E622 11/17/2017 3:49:59 PM ROOM 146 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOL 7, 3 PHASE. 4 WIRE, WITH GROUND BUS 100.4 BUS 100,4 MCB SUPPLIED FROM T-14 EQUIP WITH 100 AMP, 3 POLE CONTACTOR ON MAIN BUS DESCRIPTION LOAD LOAD BREAKER KVA QT( TYPE AMP/POLE # BREAKER LOAD LOAD # AMP/POLE TYPE QTY KVA DESCRIPTION ELECTRONICS DISPLAY REC. ELECTRONICS DISPLAY REC. ELECTRONICS DISPLAY REC. SPARE SPARE ELECTRONICS DISPLAY REC. SPARE ELECTRONICS DISPLAY REC. TV WALL RCPTS ELECTRONICS DISPLAY REC. ELECTRONICS DISPLAY REC. SPARE SPARE SPARE SPARE NEW ELECTI?ONICS SUS PANEL ELECTRONICS DISPLAY PP SPARE SPARE 1.44 1.44 1.44 0 1.44 0 1.44 0.18 1.44 1.08 0 0 3,4 2.7 2.4 1.3 0 0 R R R R R R R R R SR R PN PN PN SR SR 20/1 20/1 2(41 21-7- 2(;/1 „%liV7 20/1 20/1 20/1 20/7 3'0/1 60/3 20/1 20/1 20/1 13 15 17 19 23 25 27 31 33 35 37 39 41 C 3 C 12 A 14 B 377• C I 3 • 20 O 24 26 -5 28 A 32 B 34 C 36 A 38 B 40 C 42 20/1 211,7 204 2377 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 R R R R R ,57? R R SR R R SR R R R SR SR 0.36 0.36 0.36 0.36 0 0 .7; 0 0 0 0.36 0.36 0 0.36 0.36 TV WALL RCPTS TV WALL RCPTS TV WALL RCPTS TV WALL RCPTS SPARE SPARE SPARE SPARE SPARE 1302 3713 TV WALL RCPTS TV WALL RCPTS SPA TV WALL RCPTS TV WALL RCPTS 0.18 SHOWCASE WALL PLUGSTRIP 0.18 SHOWCASE WALL PLUGSTRIP 0.36 ENTERT. DSPLY RCPT 0 SPARE O SPARE O SPARE Demand Load KVA AMPS Phase A Phase B Phase C Total Average *Spares not included 7.7 7.1 6.2 20.9 63.8 58.9 51.4 58.1 Type L R PN PW MN MNI MS MW KT Total KVA Factor KVA 0.0 x 1.2... 0.0 14.8 x 0.5 = 12.4 *100% of 1st 10kva, plus 50% of remainder. 8.5 x 1 = 8.5 0.0 x1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 0.0 x 1 = 0.0 23.3 Total Connected KVA 0.0 x 0.6... 0.0 20.9 Total Demand KVA 23.3 20.9 58.1 Total Demand Amps 7-0627 10/19/17 LP6A NEW ROOM -155 120/208 Wye , 3 PHASE, 4 WIRE, WITH GROUND BUS SURFACE 150 A TOP FEED MCB 10,000 RMS SUPPLIED FROM T-12 EQUIP WITH 150AMP, 3 POLE CONTACTOR ON MAIN BUS P# Circuit Description LOAD TYPE CB P A B c A B C P CB TYPE LOAD Circuit Description P# 1 BEAUTY VALANCE PLUGSTRIP R 20 2 0.72 1.44 2 20 R BEAUTY DSPLY RCPTS 2 3 A&A TRACK SALES FLOOR -- -- -- 1 0.72 1.44 1 -- -- -- -- -- 4 5 BEAUTY VALANCE PLUGSTRIP R 20 2 0.90 1.08 2 20 R BEAUTY DSPLY RCPTS 6 7 -- A&A TRACK SALES FLOOR -- -- -- -- 0.90 1.08 1 -- -- -- -- -- 8 9 BEAUTY DSPLY RCPTS R 20 1 0.36 0.36 1 20 R BEAUTY DSPLY RCPTS 10 11 BEAUTY DSPLY RCPTS R 20 2 1.08 1.44 2 20 R BEAUTY WALL PLUGSTRIP 12 13 -- A&A TRACK SALES FLOOR -- -- -- -- 1.08 1.44 1 -- -- -- -- -- 14 15 BEAUTY WALL PLUGSTRIP R 20 2 0.54 0.36 2 20 R BEAUTY WALL PLUGSTRIP 16 17 -- PA E -- -- -- 1 0.54 0.00 1 20 -- SPARE -- 18 19 BEAUTY DSPLY RCPTS R 20 1 0.36 0.54 2 20 R BEAUTY WALL PLUGSTRIP 20 1 : ,$ D L T r 0 1 0.00 54 1 -- -- -- -- -- 22 23 MI SPARE -- 20 1 0.00 1.9 1 20 L A&A TRACK SALES FLOOR 24 IllSPARE PARE -- 20 1 0.00 1.92 1 20 L A&A TRACK SALES FLOOR 26 27 S E U 1E" L 0" 0 E -- 2 1 • 1.92 1200 20 L A&A TRACK SALES FLOOR 28 29 SALES UNDERFLOOR POWER R 20 1 0.54 1 1.92 1 2 L A&A TRACK SALES FLOOR 30 31 SALES UNDERFLOOR POWER R 20 1 0.36 1.921 1 200 L TRACK LTG DECORATIVE HOME 32 33 GUEST SERVICE LED RECEPTS R 20 1 0.54 1.92 1 1 2 L BEAUTY TRACK LIGHTING 34 35 35 SPARE FITTING RM MIRROR/PEND... L; R 20 20 1 0.00 1.55 0.00 1.9 1 20 -- L BRAND TRACK LIGHTING 36 36 37 SPARE SALES UNDERFLOOR POWER R 20 20 1 0.54 0.00 0.81 1 1 20 -- L PROMO LIGHTING 38 38 39 SPARE SALES UNDERFLOOR POWER R 20 20 1 0.00 0.54 0.00 0.18 1 1 20 -- R SINGLE FITTING RM PP 40 40 41 SPARE SALES UNDERFLOOR POWER R 20 20 1 0.00 0.36 0.00 0.54 1 20 -- R SALES UNDERFLOOR POWER 42 42 TOTALS: kVA 13.1 10.1 14.1 Amps 113 85 122 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals L 14358 VA 125.00% 17948 VA R 23040 VA 71.70% 16520 VA Total Conn. Load: 37.4 kVA Total Est. Demand: Total Est. Demand: 34.5 kVA Total Conn. Current: Total Conn. Current: 104 A Total Est. Demand Current: Total Est. Demand Current: 96 A 19=16 NEW 120/208 Wye , 3 PHASE, 4 WIRE, WITH GROUND BUS SURFACE 100 A TOP FEED MCB 10,000 RMS SUPPLIED FROM T-8 EQUIP WITH 100AMP, 3 POLE CONTACTOR ON MAIN BUS P# Circuit Description LOAD TYPE CB P A B c A B C P CB TYPE LOAD Circuit Description P# 1 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 2 3 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 4 5 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 6 7 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 8 9 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 10 11 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 12 13 A&A TRACK SALES FLOOR L 20 1 1.92 0.00 1 20 -- SPARE 14 1 A -- 2d 0.0 0.00 1 20 -- SPARE 16 dl.k....4, PA E -- 1 A99) 0.00 1 20 -- SPARE 18 19 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 20 21 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 22 23 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 24 25 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 26 27 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 28 29 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 30 31 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 32 33 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 34 35 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 36 37 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 38 39 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 40 41 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 42 TOTALS: kVA 5.8 3.8 3.8 Amps 48 32 32 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals L 13440 VA 125.00% 16800 VA Total Conn. Load: 13.4 kVA Total Est. Demand: 16.8 kVA Total Conn. Current: 37 A Total Est. Demand Current: 47 A GENERAL NOTES A. INSTALL OWNER FURNISHED CIRCUIT BREAKER HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. PANELBOARD LOAD LEGEND R - RECEPTACLE L - LIGHTING PN - POWER NON -SEASONAL PW - POWER WINTER MN - MOTORS NON -SEASONAL MNI - MOTORS NON -SEASONAL INTERMITTENT MS - MOTORS SUMMER MW - MOTORS WINTER KT - KITCHEN - SPARE - SPACE REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 1 3 2017 City of Tukwila BUILDING DIVIS1C,'' RECEIVED OF TUKWILA Nov 2 1 2017 I CENTER PANELBOARD BREAKER TYPE LEGEND GFCI - GFCI BREAKER TIE - PROVIDE MECHANICAL TIE FOR SPLIT WIRE RECEPTACLE L11 o‘vii 1000 NICOLLET MALL MINNEAPOLIS, MN 55403 CUSHING TERRELL ARCHITECTS ENGINEERS www.ctagroup.com 09/29/2017 10/16/2017 11/14/2017 11/21/2017 Description PERMIT ISSUE DCN 1014990 BID SET PERMIT RESUBMITTAL Project Number Proto: P400 Version:V13A Config:RL Drawn By Author Checked By Checker PANELBOARD SCHEDULES 11/17/2017 3:50:02 PM