HomeMy WebLinkAboutPermit EL17-0805 - DCHS - TENANT IMPROVEMENTDCHS 645 ANDOVER PARK W ELI 7-0805 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049143 645 ANDOVER PARK W Project Name: DCHS ELECTRICAL PERMIT Permit Number: EL17-0805 Issue Date: 11/22/2017 Permit Expires On: 5/21/2018 Owner: Name: Address: Contact Person: Name: SOUTHCENTER CORPORATE SQUAR 635 ANDOVER PARK W #107 , TUKWILA, WA, 98188 JUSTIN BRANSON Address: 18133 NE 68 ST STE D-120 , REDMOND, WA, 98052 Contractor: Name: PRIDE ELECTRIC INC Address: 18133 NE 68 ST, STE D120, REDMOND, WA, 98052 License No: PRIDEEI077DR Lender: Name: Address: Phone: (425) 736-2407 Phone: (425) 454-3665 Expiration Date: 3/19/2019 DESCRIPTION OF WORK: TENANT IMPROVEMENT Valuation of single family: $0.00 Valuation of mf/comm: $78,575.00 Type of Work: TENANT IMP Fees Collected: $1,794.48 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Pg/thdW Pr17 Date: '' / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 1 k -i2 - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvvw.TukwilaWA.gov Electrical Perini Project No. Date Application Accepted: „„Date Application Expii 10-13-t~ zee use,only ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION' Site Address: 645 ANDOVER PARK W, BLDG 6 King Co Assessor's Tax No.: Suite Number: Floor: 1 & 2 Tenant Name: DCHS PROPERTY OWNER Name: PINNACLE Address: 720 THIRD AVE, SUITE 1605 City: SEATTLE State: WA Zip: 98104 CONTACT PERSON — person receiving communication 1 project Name: JUSTIN BRANSON Address: 18133 NE 68TH ST, SUITE D-120 City: REDMOND State: WA Zip: 98052 Phone: (425) 736-2407 Fax: Email: jbranson@prideelectric.com New Tenant: 0 Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: PRIDE ELECTRIC Address: 18133 NE 68T11 ST, SUITE D-120 City: REDMOND State: WA Zip: 98052 Phone: (425) 736-2407 Fax: Contr Reg No.: PRIDEEI077DR Exp Date: 03/19/2018 Tukwila Business License No.; 09-1940 Valuation of Project (contractor's bid price): $ 78,575 Scope of Work (please provide detailed information): TENANT IMPROVEMENT Will service be altered? ❑ Yes 123 No Adding more than 50 amps? ❑ Yes m No Type of Use: Type of work: ❑ New 0 Addition ❑ Service Change 0 Remodel ® Tenant Improvement 0 Low Voltage ❑ Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applications-Handouts \Pennit Applications \Pt7F's\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $1 1.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FF F,*** PERM'I'T`AFPLTC 01NNOTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE'SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 10/13/2017 Print Name: JUSTIN BRANSON Day Telephone: Mailing Address: 18133 NE 68TH ST, SUITE D-120 REDMOND WA 98052 City W:\Permit Center Applications -Handouts \Permit Applications\PDF's\Electrical Permit Application Revised I-I-17.docx Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY :' PAID $1,794.48 EL17-0805 Address: 645 ANDOVER PARK W Apn: 2623049143 $1,794.48 ELECTRICAL $1,725.46 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,380.37 PLAN CHECK FEE R000.345.832.00.00 0.00 $345.09 TECHNOLOGY FEE $69.02 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12566 R000.322.900.04.00 0.00 $69.02 $1,794.48 Date Paid: Friday, October 13, 2017 Paid By: PRIDE ELECTRIC INC Pay Method: CHECK 7115 Printed: Friday, October 13, 2017 1:23 PM 1 of 1 SYSTEMS P 1 64-a( IT NO. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367 Project: j.),c14.5Type of Inspection: 6M Address: 6�5,-- ,pJ Date Called: Special Instructions: Date Wanted: / �li/� Ld+„3,4---,_ p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ptw_)6,..0- 7/. 1 • fi\lAt/ Inspector: " Date: 4167 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2 - INSPECTION NO. INSPECTION RECORD Retain a copy with permit t,i 7.-oi PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367 Project: (1L� `z Type of Inspection:4-L___ 6.4 .2--,L - 1,�� a A i l5i f' °t TO /c5=st � Address: A—Pui Date Called: _......._ Special Instructions: Date Wanted:r ai. P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r -- 01, priAr TO F1 - i~i t. r.A1. --- -(\ CX -r, r ,c ,,& .2--,L - 1,�� a A i l5i f' °t TO /c5=st � ����/f u L--0d-/0-J �) I5ice tr N � ,f ,tiy_r,irs ., p� lc.) ,.r s J C(R',---4)5 �'''S J i i- ?",a 6" , Z-&& KC L-17.4, .a), '-A) -- \ ,,' r -` � ? P n t -f.:) 6 r A . , p Inspector: /1/ Ale\ Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: kil Address: Ns—+p'v Date Called: Special Instructions: rioili * Date Wanted: a i ,: p.m. Requester: 111 Phone No: KiApproved per applicable codes. El Corrections required prior to approval. COMMENTS: tifr - (6tu'f J41:4 fA 4( 1. Inspector: -r Date: O i-� REINSPECTION FEE REQUIRED. Prior to next inspectio fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 9ERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL 17-0805 PROJECT NAME: DCHS SITE ADDRESS: 645 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 10/13/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ACT. 1011:�1 Building Division IN Public Works n Fire Prevention Structural n Planning Division riPermit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/17/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/14/17 Approved n Approved with Conditions n Corrections Required _ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 PRIDE ELECTRIC INC Hone Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 3 SEARCH A -Z Index Help My L&I Workplace Rights Trades & Licensing PRIDE ELECTRIC INC Owner or tradesperson Principals GOAD, CHRISTOPHER J, PRESIDENT GOAD, ROBERT L, VICE PRESIDENT GOAD, KIRK A, SECRETARY GOAD, CHRISTOPHER J, AGENT SEELEY, ROBERT M, PRESIDENT (End: 03/15/2005) SEELEY, KAROLYN J, SECRETARY (End: 03/15/2005) SEELEY, ROBERT M, AGENT (End: 03/15/2005) Doing business as PRIDE ELECTRIC INC WA UBI No. 601 451 700 18133 NE 68TH ST D120 REDMOND, WA 98052 425-454-3665 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. PRIDEEI077DR Effective — expiration 03/19/1993— 03/19/2019 Designated administrator GOAD, CHRISTOPHER J License type Master Electrician Bond TRAVELERS CAS & SURETY CO Bond account no. 103366931 Active. Meets current requirements. License no. GOAD*CJ955DG $4,000.00 Received by L&I Effective date 04/01/2005 03/17/2005 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 10/25/2017 PRIDE ELECTRIC INC License Violations Infraction no. EMOMJ00691 Issue date 11/24/2015 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. ELYOD00260 Issue date 10/09/2013 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Satisfied RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 842,543-00 Doing business as PRIDE ELECTRIC Estimated workers reported Quarter 2 of Year 2017 "76 to 100 Workers" L&I account contact T3 / KAYLENE MONIER (360)902-6627 - Email: BRKB235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/09/2012 Inspection no. 315812677 Location 2701 142nd Ave E Sumner, WA 98390 Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 10/25/2017 CIRCUITING SYMBOLS HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION JUNCTION BOX, CEILING/WALL POWER SYMBOLS DUPLEX RECEPTACLE 120V DUPLEX "CONTROLLED" RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V EE9 DOUBLE DUPLEX "CONTROLLED" RECEPTACLE 120V eth MODULAR FURNITURE DUPLEX RECEPTACLE All MODULAR FURNITURE "CONTROLLED" DUPLEX RECEPTACLE DUPLEX / QUAD RECEPTACLE - GENERATOR POWER DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFCI DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE DISCONNECT SWITCH FUSED DISCONNECT MOTOR CONNECTION EQUIPMENT CONNECTION MOTOR RATED SWITCH ELECTRICAL PANEL LIGHTING PANEL w 0: \PROJECTS\2017 PROJECTS\17030 — DCHS WORKSOURCE (WJA)\CADD\17030 — E001.DWG 9/14/2017 5:07 Ptd SYMBOLS & ABBREVIATIONS SIGNAL & COMMUNICATION SYMBOLS CI MAGNETIC DOOR HOLD -OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. ❑F FIRE ALARM MANUAL STATION +48" Cal SMOKE DETECTOR R "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK-UP CO COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" R UNLESS NOTED OTHERWISE "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. I>O COMBINATION HORN/STROBE, CEILING MOUNTED FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" >0 FIRE ALARM STROBE ONLY, CEILING MOUNTED 40 FIRE ALARM REMOTE INDICATOR LIGHT CO FIRE ALARM BELL/CHIME w ® TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" D DATA OUTLET FAX LOCATION: PROVIDE ANALOG TELEPHONE LINE SINGLE OR DOUBLE GANG BOX, RACEWAY TO ACCESSIBLE CEILING SPACE WITH BLANK COVER PLATE. WIRELESS ACCESS POINT. a D ID TAG MISCELLANEOUS FLAG NOTE REVISION SYMBOL EQUIPMENT IDENTIFIER xx 0 I 1 gem LIGHTING SYMBOLS 1X4 FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE CEILING MOUNTED DOWNLIGHT 4' LINEAR PENDANT LIGHT FIXTURE RADIANT HEAT PANEL BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN - ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH DIMMER/SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION WALL MOUNT OCCUPANCY SENSOR CEILING MOUNT OCCUPANCY SENSOR CEILING OCCUPANCY SENSOR PHOTO -CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH RISER SYMBOLS -- CIRCUIT BREAKER FEEDER DESIGNATION —o`er_ FUSED SWITCH GROUND GENERAL NOTES: 1. (1) CAT6A FOR STANDARD NETWORK DROP TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. ALL RUNS SHALL BE LESS THAN 290'. IF LENGTH ISSUES COME UP, CONTRACTOR SHALL COORDINATE WITH KING COUNTY LT. DEPARTMENT. ALL CABLING SHALL BE FASTENED PER 2017 KING COUNTY I.T. STANDARDS. 2. WAP = WIRELESS ACCESS POINT WITH (2) CAT6A CABLES TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. WIRELESS DEVICE PROVIDED BY KING COUNTY, INSTALLED BY CONTRACTOR. 3. (2) DATA RACKS AND PATCH PANELS PROVIDED AND INSTALLED BY CONTRACTOR. PANEL 4. CR: CARD READER, REFER TO DOOR SCHEDULE ON A-601 FOR LOCATIONS. PROVIDE 4" SQUARE J -BOX MOUNTED AT 42" AFF WITH 1"C-PULLSTRING TO ACCESSIBLE CEILING SPACE. ALL WIRING BY OWNERS SELECTED VENDOR. PANEL TRANSFORMER AVAILABLE SHORT CIRCUIT CURRENT 1-0-9 METER ABBREVIATIONS AFF ABOVE FINISHED FLOOR A, AMP AMPERE CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED EXST, EXSTG, (E) EXISTING FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER IH INSTA HOT J -BOX JUNCTION BOX LTG LIGHTING PNL PANEL PROVIDE FURNISH AND INSTALL REC, RECEPT RECEPTACLE TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE ✓ VOLT W WIRE OR WATT PHASE W/0 WITHOUT WP WEATHERPROOF i SEPARATE PE; '41 REQUIRrD EKMechanicai Electrrca1 ail/Gas l lumbing Piping City of Tutc,vila FILE COPY Permit No. o� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Civision. INOTE: Revisions will require Z nr-. plan submittal i and may inc.'ude c dr tonal pia By: Date: �_► l - �� - h� City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER SHEET LIST Sheet Number Sheet Title E-001 SYMBOL LEGEND, ABBREVIATIONS, SHEET LIST E-002 FIXTURE SCHEDULE, NREC FORMS ED101 FIRST FLOOR POWER AND SIGNAL DEMO PLAN ED102 FIRST FLOOR LIGHTING DEMO PLAN ED103 SECOND FLOOR POWER AND SIGNAL DEMO PLAN ED104 SECOND FLOOR LIGHTING DEMO PLAN E-201 FIRST FLOOR POWER AND SIGNAL PLAN E-202 SECOND FLOOR POWER AND SIGNAL PLAN E-301 FIRST FLOOR LIGHTING PLAN E-302 SECOND FLOOR LIGHTING PLAN E-501 PARTIAL RISER DIAGRAM E-601 PANEL SCHEDULES E-602 PANEL SCHEDULES (2) E-603 PANEL SCHEDULES 3) FINAL ISSUED FOR CONSTRUCTION - SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPWRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 TENANT IMPROVEMENTS 0 m CO 00 oC CO a LU > 0 0 Z Li) ISSUE / REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 2.4 2017 41( City of Tukwila, BUILDING DIVISION Project No.:15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SYMBOL LEGEND, ABBREVIATIONS, SHEET LIST E-001 9/14/201/ b: 0/ PM 0: \PNU,kC IS\201 / Pt 0JLC IS\1 /0.50 LIGHTING FIXTURE SCHEDULE Date 9A4/2017 Calculation Area NOTES CI New Construction 0 Addition- stand alone Spaces where ' 50%of i Spaces where50% of Q luminaires are replaced luminaires are replaced LAMP ©Clear the Use (C506) For Binding Department Use 0 Addition TYPE MANUFACTURER SERIES NO. (CATALOG NO.) VOLT NO. TYPE BALLAST FIXTURE WATTS DESCRIPTION INTERIOR LIGHTING Watts Allow ed (watts/ft2 x area) 18011111111 E3 RECESSED LINEAR WALL. WASH - IL F32T8 r El EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2X4' FIXTURE TO REMAIN iN PLACE WiTH NO MODIFICATIONS. El E EXISTING - 277 2 F32T8 - 64 EASING RECESS MOUNT 2'X4' FIXTURE PROVIDED WITH EMERGENCY BATTERY PACK TO 'REMAIN IN PLACE WITH NO MODIFICATIONS. E2 EXISTING - 277 1 18W TRT - 18 ;EXISTING RECESS MOUNT DOWNLIGHT FIXTURE TO REMAIN IN PLACE WITH NO MODIFICATIONS. E3 EXISTING - 277 1 F32T8 - 32 EXISTING RECESS MOUNT 7X4' FiXTURE TO BE REMOVED OR RELOCATED. L1 TECH UGHITNG MINI ECHO PENDANT 12V VIA 120/277 1 LED INTERNAL DRIVER g TRANSLUSCENT CYLINDER PENDANT FIXTURE. LOW VOLTAGE MAGNETIC TRANSFORMER REQUIRED. CONFIRM COLOR TEMPERTURE, FIXTURE FINISH AND MOUNTING TYPE WITH ARCHITECT. L2 PHILIPS L.IGHTOLIER CALCULITE LED 3 277 1 LED INTERNAL DRIVER 11 1000 LUMEN RECESS MOUNT LED DOWNUGHT. CONFIRM FIXTURE COLOR TEMPERTURE, FINISH, DISTRIBUTION AND LENSING WITH ARCHITECT. FIXTURE TO BE PROVIDED WTlH 0-10V DIMMING. L3 TBD X2E 3W LED DUAL HEAD EMERGENCY FIXTURE 277 1 LED INTERNAL DRIVER 50 TDB L4 APOLLO LED SERIES 120V N/A LED INTERNAL DRIVER 18 WALL MOUNT LED VANITY FIXTURE. SATIN NICKEL HOUSING, WHITE ACRYLIC DIFFUSER, COLOR TEMPERATURE = 3000K, NOMINAL LENGTH = 28" RI EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2'X4' FIXTURE TO BE REMOVED OR RELOCATED. R1 E EXISTING - 277 2 F32T8 - 64 EXISTING RECESS MOUNT 2'X4' FIXTURE PROVIDED WITH EMERGENCY BATTERY PACK TO BE 'REMOVED OR RELOCATED. R2 EXISTING - 277 1 18W TRT - 18 EXISTING RECESS MOUNT DOWNLIGHT FIXTURE TO REMAIN IN PLACE WITH NO MODIFICATIONS. R3 EXISTING - 277 1 F32T8 - 32 EIS11NG RECESS MOUNT 2'X4' FIXTURE TO BE REMOVED OR RELOCATED. R4 EXISTING - 277 1 F32113 - 32 36 CFL MONOPOINT PENDANT FIXTURE TO BE REMOVED OR RELOCATED TIE EXISTING - 120 1 - 50 EXISTING RECESS TRACK LIGHTING TO REMAIN IN PLACE WITH NO MODIFICATIONS. IIR EXISTING - 120 1- 50 EXISTING RECESS TRACK LIGHTING TO BE REMOVED OR RELOCATED. X1 MATCH EXISTING - 277 1 LED - 3 3W EXIT SIGN. MATCH BUILDING STANDARD. CONFIRM TYPE WITH ARCHITECT IF BUILDING STANDARD IS UNAVAILABLE. X1E }2E EXISTING EXISTING - - 277 277 1 1 LED LED- - 3 6 EXISTING 3W EXiT SIGN EXISTING 7W LED DUAL HEAD EMERGENCY FIXTURE X IR EXISTING - 277 1 LED - 3 EXISTING 3W EXIT SIGN TO BE REMOVED OR RELOCATED Interior hti lgr Space -By -Space TG -INT -SPACE Project Title: King County - CCHS WorkSource Date 9A4/2017 Calculation Area NOTES CI New Construction 0 Addition- stand alone Spaces where ' 50%of i Spaces where50% of Q luminaires are replaced luminaires are replaced ©Clear the Use (C506) For Binding Department Use 0 Addition to dsling I, Spaces where is changing LPA Calculation Type r _ CI Standard o Additional Efficiency Package Option [0 Clear C406,3 Reduced Interior Lighti ng Power To comply with C406.3, the Proposed LPD shall be 25% lower than the TargetLPA. Refer to 040E_3 for additional requirements. Maximum Allowed Lighting Wattage N0TE1 El E RECESSED 2'x 4' - 2L F32T8 Location (plan #, room #) Space Type Ceiling Height NOTe2 Gross Interior Area in ft2 Allow ed t Watts per ft2 Watts Allow ed (watts/ft2 x area) 18011111111 E3 RECESSED LINEAR WALL. WASH - IL F32T8 16 32 512 LI SUSP134DED PENDANT- 8W LED 5 8 40 12 RECESSED DOWNLIGHT - 11W Ltd 22 11 EMI= L4 18W LED DECORATIVE VANITY 18IIIIIIIII h. - RI RECESSED 2'x 4' - 21 F3218 40 64 2500 RI E RECESSED 2x 4' - 2L F32T8 13 64 Enter Lobby Art/Exhibit Display Allow ance from LTG -INT -DISPLAY NorEs Total Area Retail Display Total Existing R2 RECESSED DOWNL ff - 18W TRT LTG -INT -DISPLAY (prior to Alteration) Mowed Watts 18 Mow ance from Lighting Watts 1111131.111 . 23258 T1 E TRACK LIGHTING - 50W PER LINEAR FT 23258 Proposed Lighting Wattage NOTES Location (plan #, room#) Fixture Description NOTE d,5.6 Number of Fixtures Watts/ FxtureNOTE 7 Watts Proposed El RECESSED 2)(4' - 2L F32T8 139 64 8896 El E RECESSED 2'x 4' - 2L F32T8 19 64 t 1216 E2 RECESSED DOWNLIGHT- 18W TRT 7 18011111111 E3 RECESSED LINEAR WALL. WASH - IL F32T8 16 32 512 LI SUSP134DED PENDANT- 8W LED 5 8 40 12 RECESSED DOWNLIGHT - 11W Ltd 22 11 EMI= L4 18W LED DECORATIVE VANITY 18IIIIIIIII h. - RI RECESSED 2'x 4' - 21 F3218 40 64 2500 RI E RECESSED 2x 4' - 2L F32T8 13 64 IIIMZIIIIN R2 RECESSED DOWNL ff - 18W TRT 3 18 1111131.111 T1 E TRACK LIGHTING - 50W PER LINEAR FT 48 50 2400 XI 3W LED EXIT SIGN 11 3 111MMIN XI E 3W LED EXIT SIGN 13 3 11111Maill X2E 3W LED DUAL HEAD EMERGENCY FIXTURE 2 6 111101311111 X1 R 3W LED EXIT SIGN 2 3 6 111111111111111111111 111111111111111 IIIIIIIIIIIIII Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed TotalAllowed Watts for interior Lighting Total Proposed Watts Interior Lighting Power Allowance � mm. 18968 COMPLIES Note 1- List all unique space types per Table C405,4,2(2) that occur ;Tithe project scope, Selectspace type category per from drop down menu, Note 2- Indicate ceiling height for atriums and spaces- utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes of thru f. Note 3- List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4- For proposedFixture Description, indicate fixture type, lamp type (e.g. T.8), number of amps in the fixture, and ballast type (ii included). For track lighting, fist the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5- For fighting equipment eligible for exemption per 04095.4.1, note exception number and leave Wetfs,Fixture blank. Note 6- E:xisting-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7- For propos ed Watts/Fixture enter the luminaire wattage for installed famp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems enter the larger of the attached luminaire wattage or 50 wettsilinealfoot, or enter the wattage limit of permanent current frmiHity device. Note 8- Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9- Calculation Area Details: a. Lighting fixtures in a building addition may comply as a standalone project, or they maybe combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1, b. For alterations and building additions, provide Space Types and gross Interior areas in the Maximum Allowed Lighting Wattage table. lfa building addition will comply es combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing l'ghting wattage (priorto alteration) in the space provided in itis Mcsrimum lith-twAd 1 inhfinn WaffanAtahIe RECEIVED CITY OF TUKWILA OCT 13 2011 PERMIT CENTER .t FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 TENANT IMPROVEMENTS LD 0 CO 00 Co Ce LU 0� 0� z1-4 CO E -- ISSUE I REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 2 4 2017 City of -Tukwila BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIXTURE SCHEDULE, NREC FORMS E-002 9/14/201/ 5:U/ PM U: \PROJtC I S\201 / PKUJLC IS\1 /OM - UCHS WUKKSOUKCL (WJA)\LAUD\1 /USD - tM1Ui,DWG GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. UNLESS NOTED OTHERWISE, ALL INDICATED DEVICES, EQUIPMENT AND ASSOCIATED INFRASTRUCTURE/RACEWAY/CONDUCTOR SHOWN HATCHED ARE TO BE REMOVED BACK TO SOURCE OR NEXT INLINE DEVICE WHERE CONTINUITY IS TO BE MAINTAINED. DEVICES NOT HATCHED ARE INTENDED TO STAY AS EXISTING AND EITHER MAINTAINED OR RECONNECTED (SEE POWER PLANS). DISCONNECT AND LEAVE CONNECTED EXISTING DEVICE WIRING IN ACCESSIBLE CEILING SPACE FOR FUTURE CONNECTION. WHERE CIRCUITS ARE INDICATED THEY ARE TAKEN FROM RECORD DRAWING INFORMATION AND ARE INTENDED TO BE PULLED BACK TO ACCESSIBLE SPACE TO BE EXTENDED TO MAINTAINED AND/OR NEW DEVICE/LIGHTING/EQUIPMENT LOCATIONS. MAINTAIN CONTINUITY TO ALL REMAINING DEVICES AS REQUIRED. SEE POWER PLAN FOR DETAILS. 5. FIRE ALARM: UNLESS NOTED OTHERWISE EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES TO BE MAINTAINED AND RE -PURPOSED. ALL EXIST DEVICES IN IMMEDIATE TENANT REMODEL SPACE TO BE CLEANED AND COVERED WITH PROTECTIVE PLASTIC. NEW FIRE ALARM DEVICES WHERE REQUIRED ARE TO BE INTEGRATED INTO THE EXISTING DEVICE LOOPS. WHERE DEVICES ARE RELOCATED CONTRACTOR TO MAINTAIN CIRCUIT CONTINUITY AS REQUIRED. 6. MECHANICAL: ALL VAV BOXES AND FEEDER TRUNK LINES TO BE MAINTAINED UNDER DEMOLITION FOR REMOVAL/RELOCATION UNDER TENANT IMPROVEMENT BUILD OUT. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND PROVIDE RECORD DRAWING INDICATING EXISTING BOX 0 0 LOCATIONS, NAMEPLATE INFORMATION INCLUDING VOLTAGE, HEATER/FAN SIZE (RATINGS) AND CONNECTED FEEDER TRUNK LINE CIRCUITS INFO FOR FUTURE RELOCATION/REPURPOSING. 7. SECURITY/ACCESS CONTROL: UNLESS NOTED OTHERWISE INDICATED EXISTING DEVICES TO BE REMOVED AND RE -PURPOSED. REMOVE ASSOCIATED CABLING/RACEWAY/INFRASTRUCTURE BACK TO SOURCE (IT/TELECOM ROOM). 8. INDICATED EXISTING FLOOR BOX/POKE THRU DEVICES TO BE REMOVED AND FIRE SEALED. CONTRACTOR TO VERIFY FINAL QUANTITY ON SITE. REMOVE ALL ASSOCIATED CABLING/INFRASTRUCTURE BACK TO SOURCE OR MAINTAIN CONTINUITY TO NEXT INLINE DEVICE. FLAG NOTES: FIRE ALARM DEVICE TO BE RELOCATED. SEE SHEET E-201 FOR NEW LOCATION. u SUMP PUMP UP u 2 11 7 FEC to PANEL PA2 U.O.N Mai PANEL PA1 U.O.N 1 FEC 1i1 32., 1— 1 O. IL /\ 25 +84"' t 41 Li 25 27 'o 14 14 1%;L°J 1 1 n 11 I II 11 I I L°} / 39 394 25 ick }I8 39 41 11 27 EL 8 PANEL PA1 U.N.o PANEL PA2 U.N.O FIRST FLOOR POWER AND SIGNAL DEMO PLAN SCALE: 1/8" = 1'-0" ELii o 0905 SCALE: 1/8" =1'-0" RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER NORTH 16' 32' FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com I EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223.6165 ISSUE / REVISIONS I In::: REVIEWED FOR COMPLIANCE WITH NFPA7O NFA OCT 2 4 7017 City of Tukwila — BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR POWER AND SIGNAL DEMO PLAN ED101 GENERAL NOTES: SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED OR RELOCATED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES MAY REQUIRE BEING RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH AN NEW OR EXISTING PHOTOCELL AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 5. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAYS AS INDICATED/REQUIRED IN NEW E-3 SERIES LIGHTING PLANS. 6. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: EXISTING SWITCH(S) TO BE RELOCATED. SEE SHEET E-301 FOR NEW LOCATION. EXISTING OCCUPANCY SENSOR TO BE RELOCATED. SEE SHEET E-301 FOR NEW LOCATION. EXISTING EXIT SIGN TO BE RELOCATED. SEE SHEET E-301 FOR NEW LOCATION. z x FIRST FLOOR LIGHTING DEMO PLAN SCALE: 1/8" = 1'-0" ELr7o 90 S SCALE: 1/8" =1'-0" 0' RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER NORTH 8' 16' 32' FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Salle 2C tel: (206)223-6446 Seattle, Washington 98104 tax: (206)223-6465 kip ti) id - di ■ z (.9 w a Ce W O O °° U) oC °C00 Z r 5oc Q D011 w, O 1. > \ U z o_I 0 W < Q 1-1 Z 3 L...1 I-2 0 I— qo E - ISSUE / REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC OCT 2 4 2017 City of Tukwila BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR LIGHTING DEMO PLAN ED102 GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. UNLESS NOTED OTHERWISE, ALL INDICATED DEVICES, EQUIPMENT AND ASSOCIATED INFRASTRUCTURE/RACEWAY/CONDUCTOR SHOWN HATCHED ARE TO BE REMOVED BACK TO SOURCE OR NEXT INLINE DEVICE WHERE CONTINUITY IS TO BE MAINTAINED. DEVICES NOT HATCHED ARE INTENDED TO STAY AS EXISTING AND EITHER MAINTAINED OR RECONNECTED (SEE STAI DN POWER PLANS). DISCONNECT AND LEAVE CONNECTED EXISTING DEVICE WIRING IN ACCESSIBLE CEILING SPACE FOR FUTURE CONNECTION. WHERE CIRCUITS ARE INDICATED THEY ARE TAKEN FROM RECORD DRAWING INFORMATION AND ARE INTENDED TO BE PULLED BACK TO ACCESSIBLE SPACE TO BE EXTENDED TO MAINTAINED AND/OR NEW DEVICE/LIGHTING/EQUIPMENT LOCATIONS. MAINTAIN CONTINUITY TO ALL REMAINING DEVICES AS REQUIRED. SEE POWER PLAN FOR DETAILS. 5. FIRE ALARM: UNLESS NOTED OTHERWISE EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES TO BE MAINTAINED AND RE -PURPOSED. ALL EXIST DEVICES IN IMMEDIATE TENANT REMODEL SPACE TO BE CLEANED AND COVERED WITH PROTECTIVE PLASTIC. NEW FIRE ALARM DEVICES WHERE REQUIRED ARE TO BE INTEGRATED INTO THE EXISTING DEVICE LOOPS. WHERE DEVICES ARE RELOCATED CONTRACTOR TO MAINTAIN CIRCUIT CONTINUITY AS REQUIRED. 6. MECHANICAL: ALL VAV BOXES AND FEEDER TRUNK LINES TO BE MAINTAINED UNDER DEMOLITION FOR REMOVAL/RELOCATION UNDER TENANT IMPROVEMENT BUILD OUT. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND PROVIDE RECORD DRAWING INDICATING EXISTING BOX LOCATIONS, NAMEPLATE INFORMATION INCLUDING VOLTAGE, HEATER/FAN SIZE (RATINGS) AND CONNECTED FEEDER TRUNK LINE CIRCUITS INFO FOR FUTURE RELOCATION/REPURPOSING. 7. SECURITY/ACCESS CONTROL: UNLESS NOTED OTHERWISE INDICATED EXISTING DEVICES TO BE REMOVED AND RE -PURPOSED. REMOVE ASSOCIATED CABLING/RACEWAY/INFRASTRUCTURE BACK TO SOURCE (IT/TELECOM ROOM). 8. INDICATED EXISTING FLOOR BOX/POKE THRU DEVICES TO BE REMOVED AND FIRE SEALED. CONTRACTOR TO VERIFY FINAL QUANTITY ON SITE. REMOVE ALL ASSOCIATED CABLING/INFRASTRUCTURE BACK TO SOURCE OR MAINTAIN CONTINUITY TO NEXT INLINE DEVICE. FLAG NOTES: FIRE ALARM DEVICE TO BE RELOCATED. SEE SHEET E-202 FOR NEW LOCATION. ELECT, �1r• Ll LI PB1/5 P81/3 5 PB1/11 36"PB1/ u B F PB1/20 PB1/1 -12 0PB1/22 PB1/22 PB1 /24,26 P81/20 C Iv N PB1/5 PB1 /1 PB X13 PB1/19 PB1/2 6.a `J C PB1/4 PB1/19 n P81/12 PB1/8 PB2134 _ PB1/6 B 36"I B P83/3 B PB1/1 36" J B U U P81/31,33,35 I P81/1 061r:14,10 PB3581/37,39,4 PB1/1 PB1/15 P82/18 __CIo t o0 PB3/5 •4. BB2/18 D PB1/8 P82/20,22,24 P82/26728;30 PB1/12 FURNITURE COIL --- PB1f24,26,28 PB1/10` P 3/9'4 rej \ I i i �, 83/9 J I I `1% 4t -0 PB3/5, • PB3/8 PB3/6 – rtj O JB1 PB3/5 P63/5 P821/25 P02/2 P8/27 n P63/3 CID P83/6 PB3/6 no © o PB2/25 171 282/27 PB2/27 r1 PB2/2 r , PB2/2 -P82/19 P82/290 PB /27 PB2/29 P82/19 PB2/23 PB2/19 O ❑ r4 P03/5 PB3/2 `B1 P 3/7 PB3/2iri 1 P 3/7 'PB PB3/4 I IJ B3/4 PB3/4 P83/6 I DN Ii e- PB1 /19 L3 62/19; =' PB2/21 82/19, n P62/6,8,10 P82/23 PB2/1 P82/1 PB2/15 r, PB2/13 P 2/17 71 PB2/9'• SECOND FLOOR POWER AND SIGNAL DEMO PLAN SCALE: 1/8" = 1'-0" P 3 ® 72/90 Pt2/90 0 0 £Lr7o $0 SCALE: 1/8" = 0' 4' 16' RECEIVED CITY OF TUKWILA 32' OCT 13 2017 PERMIT CENTER NORTH FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax (206)223-6465 W U oC 0 (4/1 zY o� U � z= 1-11U �1 D TENANT IMPROVEMENTS 0 00 0000 DC 00 LCL w� O� 0 J z H Q 'o ISSUE / REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA 70 d NEC OCT 2 4 2017 City of -Tukwila BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR POWER AND SIGNAL DEMO PLAN ED103 I-17-18 I GENERAL NOTES: 1. SOLID LINE WORK INDICATES EXISTING TO REMAIN. 2. DASHED LINE WORK INDICATES EXISTING TO BE DEMOLISHED OR RELOCATED. 3. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 4. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES MAY REQUIRE BEING RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH AN NEW OR EXISTING PHOTOCELL AS NOTED ON NEW LIGHTING LAYOUTS ON E3 SERIES LIGHTING PLANS. 5. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAYS AS INDICATED/REQUIRED IN NEW E-3 SERIES LIGHTING PLANS. 6. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: EXISTING SWITCH(S) TO BE RELOCATED. SEE SHEET E-302 FOR NEW LOCATION, EXISTING OCCUPANCY SENSOR TO BE RELOCATED. SEE SHEET E-302 FOR NEW LOCATION. al x x SECOND FLOOR LIGHTING DEMO PLAN SCALE: 1/8" = 1'-0" araTwo 9�.r ssw SCALE: 1/8" =1'-0" RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER NORTH 0' 16' 32' FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com I EXPIRES BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 V w w 0 U x Ca Ce Lu D > oo 00° oc 1— o.,_ a_ Il—I w U x 0 J (.9 (f)aC Q~ x = E �,ULn k0 I— ISSUE I REVISIONS REVIEWED FOR COMPLIANCE WITH NPPA70 - NEC OCT 242017 City ofTukwila BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR LIGHTING DEMO PLAN ED104 t201.DWG 9/14/201 / 5:OS PM 0: \I'KOJtC IS\201 / PROJLC IS\1 /OS0 - OCHS WORKSOUKCt (WJAJ\CAOU\I /0.50 - GENERAL NOTES: 1. (1) CAT6A FOR STANDARD NETWORK DROP TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. ALL RUNS SHALL BE LESS THAN 290'. IF LENGTH ISSUES COME UP, CONTRACTOR SHALL COORDINATE WITH KING COUNTY I.T. DEPARTMENT. ALL CABLING SHALL BE FASTENED PER 2017 KING COUNTY I.T. STANDARDS. 2. WAP = WIRELESS ACCESS POINT WITH (2) CAT6A CABLES TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. WIRELESS DEVICE PROVIDED BY KING COUNTY, INSTALLED BY CONTRACTOR. 3. (2) DATA RACKS AND PATCH PANELS PROVIDED AND INSTALLED BY CONTRACTOR. 4. CR: CARD READER, REFER TO DOOR SCHEDULE ON A-601 FOR LOCATIONS. PROVIDE 4" SQUARE J -BOX MOUNTED AT 42" AFF WITH 1"C-PULLSTRING TO ACCESSIBLE CEILING SPACE. ALL WIRING BY OWNERS SELECTED VENDOR. 5. DASHED LINE WORK INDICATES EXISTING TO REMAIN. 10 6. CONTROLLED RECEPTACLES (SHADED - SEE SYMBOL LEGEND): UNLESS NOTED OTHERWISE, PROVIDE 20A AUXILIARY RELAY POWER PACK TIED TO LIGHTING CONTROL SENSOR IN AREA SERVED FOR OPERATION OF CONTROLLED RECEPTACLES. 7. ELECTRICAL CONTRACTOR TO PROVIDE POWER/DATA RACEWAYS AND POWER FEEDS TO MODULAR FURNITURE CONNECTION POINT. FINAL TERMINATION OF POWER AND DATA BY OTHERS. 8. FIRE ALARM DESIGN IS BIDDER DESIGN. SEE SPECIFICATIONS FOR DETAILS. EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES SHOWN FOR CLARITY ONLY. FIRE ALARM CONTRACTOR TO RELOCATE/REUSE EXISTING DEVICES AS REQUIRED, MODIFYING THE LAYOUT AND LOCATION OF DEVICES AS REQUIRED FOR NEW CONSTRUCTION AND CODE COMPLIANCE. 9. INDICATED HOME RUN CIRCUITS HAVE BEEN IDENTIFIED FROM SERVING EXISTING PANEL SCHEDULES AND ASSUMES THAT HOMERUNS WERE LEFT IN ACCESSIBLE CEILING SPACE. EVERY EFFORT HAS BEEN TAKEN TO RE -PURPOSE EXISTING CIRCUITS IN SAME GENERAL VICINITY AS NOTED ON RECORD DOCUMENTS, HOWEVER CONTRACTOR UNDERSTANDS AND SHALL PRICE ACCORDINGLY THAT CIRCUIT HOMERUNS TO SERVING PANELS MAY BE REQUIRED WHERE EXISTING CIRCUITS DO NOT EXIST. FLAG NOTES: PROVIDE A/C GRADE, FIRE RATED, 3/4" PRIMED AND PAINTED PLYWOOD. FIRE RATING STAMP SHALL BE VISIBLE FOR INSPECTION BY AHJ. PROVIDE MINIMUM OF 8'X4' CONFIRM LOCATION AND SIZE OF BACKBOARD WITH KCIT PRIOR TO INSTALLATION. TELECOMMUNICATIONS GROUNDING BUS BAR. CONFIRM SIZE AND LOCATION WITH KCI T. PROVIDE (3) CONTINUOUS RUNS OF 4" PVC CONDUIT ROUTED THROUGH CEILING SPACE FROM MOF ROOM UP TO 2ND FLOOR IDF ROOM ABOVE. CONFIRM EXACT ELEVATION, LOCATION AND QUANTITY WITH KCIT PRIOR TO CORE DRILLING AND ROUTING OF CONDUIT. PROVIDE 12" CABLE TRAY. CONFIRM SIZE, LENGTH AND LOCATION WITH KCIT PRIOR TO INSTALLATION. DISCONNECT EXISTING RECEPTACLE AND REPLACE WITH NEW ABOVE GFCI RECEPTACLE ABOVE SINK EXTEND CONDUCTORS AS NEEDED. DEDICATED 208 - 240V, 50/60Hz + 1 DATA FOR EACH EXISTING DEVICE TO BE RELOCATED. MAINTAIN WIRING CONTINUITY AND DEVICE FUNCTIONALITY DURING CONSTRUCTION. PROVIDE CONNECTIONS FOR HOT AND CONTROLLED DEVICES TO SYSTEMS FURNITURE. PROVIDE SEPARATE 1-1/4" RACEWAY CONNECTION TO ACCESSIBLE SPACE FOR LOW VOLTAGE CABLING. CONFIRM EXACT LOCATION PRIOR TO ROUGH -IN. CONFIRM EQUIPMENT TYPE AND POWER REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH -IN. MULTIFUNCTION PRODUCTION PRINTER. CONFIRM POWER AND RECEPTACLE CONNECTION TYPE WITH MANUFACTURER REQUIREMENTS PROVIDED BY OWNER PRIOR TO ROUGH -IN. 7It,o U[ )UU[� DOOR C-TUATOR ADA POWER/DATA POLE I I "'FOR3 BENCHING 8( WORKSIATt6NS.,_ 1 POWER + 1 DATA RECEPTACLE ON WALL FOR EACH WORKSTATION - REDUCED TO 5 WORKSTATIONS PANEL PA2 U.O.N PANEL PA1 U.O.N 1 POWER + 1 DATA RECEPTACLE ON WALL FOR EACH WORKSTATION 2 DATA. 2 DATA WALL FLOOR WALL -MO NTED M9 TO POWER + 1 DATA FAX -- POWER +2 DATA 1 POWER + 1 DATA RECEPTACLE ON WALL FOR EACH TABLE, TYP. 1 POWER 1 DATA RECEPTA LE ON WALL FOR EACH WORKSTATION PA /2 ,29 SYS EMS FURNITURE WHIP OFF WALL PANEL PA1 PANEL PA2 U.N.O ® ® U.N.O FIRST FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" POWER +1 DATA + 1 POTS FLIM a 9 y s' SCALE: 118" = King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES I -17-I8 RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER 0' 4' 16' 32' NORTH FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 ISSUE 1 REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA70-NEC OCT 2 2017 City of Tukwila BUILDING DIVISION Project No.:.15032-172 A Site No.: Drawn By: SH/TD Checked By: BB Sheet Title FIRST FLOOR POWER AND SIGNAL PLAN E-201 - OCH5 WORKSOURCE (WJA)\CADD\17030 - E202.DWG 9/14/2017 5:05 PM PROJECTS\17030 0:\PROJECTS\2017 GENERAL NOTES: 1. (1) CAT6A FOR STANDARD NETWORK DROP TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. ALL RUNS SHALL BE LESS THAN 290'. IF LENGTH ISSUES COME UP, CONTRACTOR SHALL COORDINATE WITH KING COUNTY I.T. DEPARTMENT. ALL CABLING SHALL BE FASTENED PER 2017 KING COUNTY I.T. STANDARDS. 2. WAP = WIRELESS ACCESS POINT WITH (2) CAT6A CABLES TO MDF/IDF ON ASSOCIATED FLOOR AND TERMINATE AT RACK. WIRELESS DEVICE PROVIDED BY KING COUNTY, INSTALLED BY CONTRACTOR. 3. (2) DATA RACKS AND PATCH PANELS PROVIDED AND INSTALLED BY CONTRACTOR. 4. CR: CARD READER, REFER TO DOOR SCHEDULE ON A-601 FOR LOCATIONS. PROVIDE 4" SQUARE J -BOX MOUNTED AT 42" AFF WITH 1"C-PULLSTRING TO ACCESSIBLE CEILING SPACE. ALL WIRING BY OWNERS SELECTED VENDOR. 5. DASHED LINE WORK INDICATES EXISTING TO REMAIN. 6. CONTROLLED RECEPTACLES (SHADED - SEE SYMBOL LEGEND): UNLESS NOTED OTHERWISE, PROVIDE 20A AUXILIARY RELAY POWER PACK TIED TO LIGHTING CONTROL SENSOR IN AREA SERVED FOR OPERATION OF CONTROLLED RECEPTACLES. 7. ELECTRICAL CONTRACTOR TO PROVIDE POWER/DATA RACEWAYS AND POWER FEEDS TO MODULAR FURNITURE CONNECTION POINT. FINAL TERMINATION OF POWER AND DATA BY OTHERS. 8. FIRE ALARM DESIGN IS BIDDER DESIGN. SEE SPECIFICATIONS FOR DETAILS. EXISTING FIRE ALARM INITIATING AND ANNUNCIATION DEVICES SHOWN FOR CLARITY ONLY. FIRE ALARM CONTRACTOR TO RELOCATE/REUSE EXISTING DEVICES AS REQUIRED, MODIFYING THE LAYOUT AND LOCATION OF DEVICES AS REQUIRED FOR NEW CONSTRUCTION AND CODE COMPLIANCE. 9. INDICATED HOME RUN CIRCUITS HAVE BEEN IDENTIFIED FROM SERVING EXISTING PANEL SCHEDULES AND ASSUMES THAT HOMERUNS WERE LEFT IN ACCESSIBLE CEILING SPACE. EVERY EFFORT HAS BEEN TAKEN TO RE -PURPOSE EXISTING CIRCUITS IN SAME GENERAL VICINITY AS NOTED ON RECORD DOCUMENTS, HOWEVER CONTRACTOR UNDERSTANDS AND SHALL PRICE ACCORDINGLY THAT CIRCUIT HOMERUNS TO SERVING PANELS MAY BE REQUIRED WHERE EXISTING CIRCUITS DO NOT EXIST. OUTLINE OF TELECOM ROOM BELOW 1 II l C) 81 /4 r�1) P81/19 r"'' 7-1 ,- ) 1i ti' ■ PB1v12 too., u 31 III':I.IIIE.�LII. I1 LO P81/6 P62/20,22 FLAG NOTES: PROVIDE A/C GRADE, FIRE RATED, 3/4" PRIMED AND PAINTED PLYWOOD. FIRE RATING STAMP SHALL BE VISIBLE FOR INSPECTION BY AHJ. PROVIDE MINIMUM OF 8'X4' CONFIRM LOCATION AND SIZE OF BACKBOARD WITH KCIT PRIOR TO INSTALLATION. TELECOMMUNICATIONS GROUNDING BUS BAR. CONFIRM SIZE AND LOCATION WITH KCIT. CORE DRILL AND PROVIDE (3) CONTINUOUS RUNS OF 4" CONDUIT DOWN TO MDF ROOM ROUTED THROUGH 1ST FLOOR CEILING SPACE BELOW. CONFIRM EXACT LOCATION AND QUANTITY WITH KCIT PRIOR TO CORE DRILLING AND CONDUIT ROUTING. PROVIDE 12" CABLE TRAY, CONFIRM SIZE, LENGTH AND LOCATION WITH KCIT PRIOR TO INSTALLATION. CORE DRILL FOR POKE-THRU FEED TO PROVIDE POWER AND DATA TO FURNITURE. r� moi" 8 PBI, P81/12 I P02/26,28 --�28 1 4 /i► 11 AL_ P83/3 't. 2.7_27 -2-727 WALL-M�pUNTED 2c7 � To�z 41,17' f4BL)35 &41_'35 __tt, R8/)'35 44 P81/37 1> v0 PB1(/34L PB3/5 --� ) � ` u�j' i P, 3' 7 !�\ (1ti PB1/24,26,28 28 Li 24 26 0 ( ) 264 u� ) Li , PBZ1/25 4 ROI 0 , jt,PB2/27 P01/14,16 tNr1 2 24 Q\►042 4D24 P8 3/3 i� 0 6 14 PB2/25 4 PB2/27 1 I� P82j/27 14 16 �I d 5j7 rr1 AJ PB3/5 U ) B3/2 'B3/23 )) z\ cc: PB3/3 '`TPB1 /22 Pr j4,26 'TPB1/22 PB1/20 PB1 /1 PB2/1 z EXISTING DEVICE TO BE RELOCATED. MAINTAIN WIRING CONTINUITY AND DEVICE FUNCTIONALITY DURING CONSTRUCTION. PROVIDE CONNECTIONS FOR HOT AND CONTROLLED DEVICES TO SYSTEMS FURNITURE. PROVIDE SEPARATE 1-1/4" RACEWAY CONNECTION TO ACCESSIBLE SPACE FOR LOW VOLTAGE CABLING. CONFIRM EXACT LOCATION PRIOR TO ROUGH -IN. CONFIRM EQUIPMENT TYPE AND POWER REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH -IN. PB2/1 PB 6 44 PB12 PB2/1,4--)L' P82/14 P SECOND FLOOR POWER AND SIGNAL PLAN SCALE: 1/8" = 1'-0" U FP B2/29 PB2 CIL ff82/19 PB2/23� 6 10 Au" \r: 10 P82 O 5 PB2/5 P82-f7 �RIN' . FAX 19, PB2/1 11 PB2/38,40 PB2; Pi PB2/6,8,19 C>r6 10 170— P82 10 82/23, P82/l6 P$2/111' LU r I� 16 2/16 f1 "PP 19 P a O U PB1 /1N\\\ 11 11 PB3 ELiio 6' g' SCALE: 1/8" =1'-0" RECEIVED CITY OF TUKWILA. OCT 13 2017 PERMIT CENTER 0' 4' 16' 32' NORTH FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES I — I 7-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel; (206)223-6446 Seattle, Washington 98104 tax: (206)223.6465 (I) q). i-- ■ .■ \ 6 LU LU 0 U\ CO c W • 0 O CO V) c oC c .- D 0 1--' W O > U 11 � z o C Z _ Z I-II U w Ln 0 f- co F -- ISSUE / REVISIONS r 1.. LII ii.`,! REVIEWED FOR COMPLIANCE WITH NFPA 70 4 ITEC OCT 2 4 2017 City ofTukwila BUILDING DIVISION Project No.15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title SECOND FLOOR POWER AND SIGNAL PLAN E-202 0: \PROJECTS\2017 PROJECTS\17030 1. 2. 3. GENERAL NOTES: SOLID/HEAVY LINE WORK INDICATES NEW OR RELOCATED FIXTURES AND/OR DEVICES. DASHED/LIGHT LINE WORK INDICATES EXISTING FIXTURES AND/OR DEVICES TO REMAIN RELOCATED FIXTURES TO BE RECONNECTED, EXTEND CONDUCTORS IF REQUIRED TO EXISTING 277V CIRCUIT SERVING NEW LOCATION UNLESS NOTED OTHERWISE. 4. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 5. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES ARE TO BE RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH NEW PHOTOCELL DEVICES AS NOTED ON NEW LIGHTING LAYOUTS ON E-3 SERIES LIGHTING PLANS. 6. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAY AS INDICATED/REQUIRED. 7. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER, FLAG NOTES: RELOCATED SWITCH(S). SEE SHEET ED102 FOR PREVIOUS LOCATION. RELOCATED OCCUPANCY SENSOR. SEE SHEET ED102 FOR PREVIOUS LOCATION. EXISTING RELOCATED FIXTURE TO BE RETROFITTED WITH A 0-10V DIMMING BALLAST TO ALLOW DIMMING REQUIRED FOR DAYLIGHT HARVESTING, 120V VANITY FIXTURE TO BE CONTROLLED VIA OCCUPANCY SENSOR. POWER TO BE PROVIDED BY CLOSEST GENERAL RECEPTACLE 120V CIRCUIT, JXlE LJ 11011111 ElE r u n {cel u_ u � n IIgJa'" n u,u u u u u u u u u u u C E2 ' 1 L 1-1,2c51 z� II TIE FIRST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'—O" SCALE: 1/8" =1'-0" 0 RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER NORTH 0' 8' 16' 32' FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES I-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel; (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 TENANT IMPROVEMENTS ISSUE I REVISIONS ... ......... REVIEWED FOR COMPLIANCE WITH NFPA-70 NEC OCT 2 4 2017 City of Tukwila BUILDING DIVISION Project No.:15032-17ZA Site No.: Drawn By:. SHITD Checked By: BB Sheet Title FIRST FLOOR LIGHTING PLAN E-301 9/14/201/ b: US PM - UCHS WOKKSUUKCL (WJA)\CAUU\1 /030 - LS02,UWG 0: \NKOJtC I S\201 / PROJLC 1S\1 /030 GENERAL NOTES: 1. SOLID/HEAVY LINE WORK INDICATES NEW OR RELOCATED FIXTURES AND/OR DEVICES. 2. DASHED/LIGHT LINE WORK INDICATES EXISTING FIXTURES AND/OR DEVICES TO REMAIN 3. RELOCATED FIXTURES TO BE RECONNECTED, EXTEND CONDUCTORS IF REQUIRED TO EXISTING 277V CIRCUIT SERVING NEW LOCATION UNLESS NOTED OTHERWISE. 4. EXISTING CONDITIONS INDICATED ON THIS PLAN ARE TAKEN FROM FIELD INVESTIGATION AND RECORD DRAWINGS. EVERY EFFORT HAS BEEN TAKEN TO ACCURATELY INDICATE EXISTING CONDITIONS, BUT NOT ALL FIELD CONDITIONS ARE KNOWN NOR ARE ALL FIELD CONDITIONS INDICATED. DRAWING IS INTENDED TO ESTABLISH A BASELINE FOR THE LEVEL OF DEMOLITION REQUIRED ONLY AND CONTRACTOR SHALL ASSUME UNKNOWN CONDITIONS EXIST. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING FIELD CONDITIONS PRIOR TO BID TO ASCERTAIN THE EXTENT OF DEMOLITION WORK REQUIRED FOR PROJECT AND ALL SUCH WORK SHALL BE INCLUDED IN BASE BID. 5. IN ORDER TO ACCOMMODATE NEW AUTOMATIC DAYLIGHT CONTROL ZONES, EXISTING STATIC (ON/OFF) 2X4 FIXTURES ARE TO BE RETROFIT WITH NEW 0-10 DIMMING BALLASTS AND GROUP CONTROLLED WITH NEW PHOTOCELL DEVICES AS NOTED ON NEW LIGHTING LAYOUTS ON E-3 SERIES LIGHTING PLANS. 6. CONTRACTOR SHALL REMOVE/RELOCATE FIXTURES ACCORDING TO PLANS AND EXTEND EXISTING OR SUPPLEMENTED NEW CONTROLS WIRING/RACEWAY AS INDICATED/REQUIRED. 7. RETURN ALL REMOVED AND UNUSED LIGHT FIXTURES TO OWNER. FLAG NOTES: RELOCATED SWITCH(S). SEE SHEET ED104 FOR PREVIOUS LOCATION. RELOCATED OCCUPANCY SENSOR. SEE SHEET E0104 FOR PREVIOUS LOCATION. EXISTING RELOCATED FIXTURE TO BE RETROFITTED WITH A 0-10V DIMMING BALLAST TO ALLOW DIMMING REQUIRED FOR DAYLIGHT HARVESTING. SECOND FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" ai 7 0 9 SCALE: 1/8" =1'-O" RECEIVED CITY OF TUKWILA OCT 132011 PERMIT CENTER 8' 16' 32' NORTH FINAL ISSUED FOR CONSTRUCTION - SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 (an w LU9 U CO c w \ 0 0 0,2, Ln % Q03 z �0� ws o �. o Uz Z _ z �w �� I— q)F- ISSUE I REVISIONS Project No.: 15032-17ZA Site No.: Drawn By: SHITD Checked By: BB Sheet Title SECOND FLOOR LIGHTING PLAN E-302 GENERAL NOTES: 1. EXISTING CONDITIONS INDICATED ON PLANS ARE FROM AS -BUILT DOCUMENTATION AND ARE SHOWN FOR CLARIFICATION AND TO BE FIELD VERIFIED/CONFIRMED BY ELECTRICAL CONTRACTOR. 2. LOADS INDICATED ON PANEL SCHEDULES CONFIRM EXISTING PANELS/SERVICE IS ADEQUATE TO SUPPORT NEW TENANT SPACE LOADS (SEE SHEETS E-601, E-602, E-603). 3. SCOPE OF WORK PANELS ARE EXISTING. TENANT SPACE OCCUPANCY REMAINS THE SAME WITH CIRCUITS BEING RE -PURPOSED. LOAD CALCULATIONS SHOWN FOR LOCAL PANELS ONLY BASED ON RE -PURPOSING OF LIKE TENANT SPACE. 4. EXISTING CONDITIONS INDICATED ON PLANS ARE FROM AS -BUILT DOCUMENTATION AND ARE SHOWN FOR CLARIFICATION AND TO BE FIELD VERIFIED/CONFIRMED BY ELECTRICAL CONTRACTOR. PANELS IN SCOPE OF WORK: r<"ll•,r —; — EXISTING 112.5KVA r r; lot FL 1.== 11901119001 r r t r i PANEL PANEL PB1 PB2 208/120V"208/120V ~ 208/120V 200A 100A MLO MLO 4 4 110101201 =111011 1=E1 =Sail PANEL PB3 208/120V 40A MCB r I. FLAG NOTES EXISTING BRANCH PANEL CIRCUITS TO BE MODIFIED. LOAD MODIFICATIONS SHOWN ON PANEL SCHEDULES SHEETS E-601, E-602, E-603. ss -1 EXISTING HVAC `-- ROOFTOP UNIT J] 6X6X48 WIREWAY 9/14/2017 5:08 PM - DCHS WORKSOURCE (WJA)\CADD\17030 - E501.DWG 0: \PROJECTS\2017 PROJECTS\17030 L PANELS IN SCOPE OF WORK: r PANEL LA 480/277V 200A MLO .1 I-- 1 rm. ' PANEL EL I 480/277V 100A I MLO I, r PANEL LB PANEL IN SCOPE OF WORK: 2ND FLOOR J L____ 400AF/400AS nr 11-1 GFI 400AF/400AS — — — -OEN} GFI 200AF/200AS --- nr 1111110119911 =LI =CI r—J__L_, r t PANEL PA1 208/120V 200A MLO i PANEL PA2 208/120V 100A MLO r r- — — r — — --i I EXISTING 15KVA I PANEL ATRIUM J BUILDING 6 PARTIAL RISER DIAGRAM SCALE: NONE i PANEL HV 480/277V 400A CLOJ GFI 200AF/200AS UL'" GFI 800AF/800AS nr-fn r r- GFI GFI — -� kl- -4 SPACE--- SPACE---1 PANEL IN SCOPE OF WORK: 4 r� r ---- ( Mr EL17 of, ,r RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C lel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 V (W W 0 U 2 m LLJ • co 00 (;21 V� / l y %oo rtrt V ' 2 Oc 0 IH W S CJ z o J < d~ I I LU Ln ISSUE / REVISIONS II) REVIEWED FOR COMPLIANCE WITH TPA 70 BFC OCT 2 4 2017 City of;Tukwila. BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH /TD Checked By: BB Sheet Title PARTIAL RISER DIAGRAM E-501 DCHS WORKSOURCE (WJA)\CADD\17030 - E501.DWG 9/14/2017 5:09 PILI TS\2017 PROJECTS\17030 PANEL SCHEDULE PANEL: MDP AMP: 800 iJILO Q MCB U TYPE: EXISTING [_.1 NEW [] LOCATION: ELECT ROOM LEVEL 1 STYLE: /5551 VOLTS: 480 Y/277V P: 3 AIC RATING: •e -SEE RSER DIAGRAM NEUTRAL: 100% DISTRIBUTION: CIRCUIT DESCRIPTION LOAD TYPE TRANSFORMERT-S-(PANELS PA3 & PBI -_._._. __ ROOF"fOP UNIT COMB COMB COMB MTR MTR MIR LOAD CKT KVA BKR iI 42.50 400 3 1 C1R 40.67 - 37.18 - - 36.56 2003 36,56... 3 5 P H CIR t7 CKT BKR LOAD KVA LOAD TYPE W: 4 MOUNT: 0 SURFACE 0 FLUSH FED FROM: MAIN DISTRIBUTION PANEL CIRCUIT DESCRIPTION 2 3- 400 YES 4 6 3 200 48.07 50.91 51.81 16.63 24.56 17.63 MISC COMB COMB COMB COMB COMB PANEL HV PANEL LA ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LIGHTING RESIDENT LTG/RECPT SMALL APPLIANCE LARGEST MOTOR REMAINING MOTORS GEN PURPOSE RECPT COMPUTER RECPT EQUIP/OTHER HEATING ELEVATOR p Total] KITCHEN Et (0 Total] TOTALS LOAD TYPE: CONNECTED EM.D. CALCULATED LTG RES RES MTR REC MISC MISC MSC ELEV KITCH 23.32 KVA 29.15 KVA (125%) 0.00 KVA 0.00 KVA (100/35125%) 0.00 KVA 0.00 KVA (100/35/25%) KVA 0.00 KVA (125%) 144.77 KVA 144.77 KVA (100%) 83.25 KVA 46.63 KVA ( 50% > 10KVA) 0.00 KVA 0.00 KVA (100%) 12.74 KVA 12.74 KVA (100%) 174.71 KVA 174.71 KVA (100%) 0.00 KVA 0.00 KVA (100%) 0.85 KVA 0.85 KVA (100%) 439.64 KVA 408.85 KVA 529 AMPS 492 AMPS LOAD TYPE NOTES: "COMB"-, COMBINATION LOAD TYPES ON INDICATED CIRCUIT "REV = RESIDENTIAL LTG/RECPT ORSMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC"= EQUIP, COMPUTER RED OR HTG LOAD ON INDICATED CIRCUIT AT 100% CONNECTED PHASE LOADING PHASE A: PHASE 8: PHASE C: 143.76 KVA 519 AMPERES 152.70 KVA 551 AMPERES 143.18 KVA 517 AMPERES GENERAL NOTES: 1 FLAG NOTES: PANEL SCHEDULE PANEL: LA LOCATION: ELECT ROOM LEVEL 1 VOLTS: 480 Y/277V P: AMP: 200 MLO D MOB 0 AIC RATING: -:.SEE RISER DIAORALI TYPE: EXISTING 0 NEW 0 STYLE: ].ma: NEUTRAL: 100% DISTRIBUTION: 3 (. NO --1 W: 4 MOUNT: ~D SURFACE 0 FLUSH FED FROM: MAIN DISTRIBUTION PANEL LOAD TYPE LOAD KVA CKT SKR P LOAD LOAD CET P CIM P CER P CKT LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA SKR 20 # H X SPACE SKR KVA TYPE CIRCUIT DE5CRIFT:ON PANEL LB_--- COMB_ B 4 100 . 3 1 A � 2 1 LIGHTS •PERIIVIETER -------...... - COMB _16.63 24.56 - - 3 B • 4 1 LIGHTS -SOUTH PERIMETER - ; COMB 17.63 - 5 C 6 1 SPACE VAV BOX = - .. _--- -_ A _ 5 I SPACE -- -- - - -- -- VAV BOX ---- - -- - - -i--- -- 1 9 B , 10 1 VAV BOX SPARE 3 20 .2.80 1 11 C ` 12 1 4,33 20 3 SPACE VAV BOX1 16 - - 13 A 14 1 MSC 4.33- VAV BOX VAV BOX 18 - 1 15 B 16 1 - MISC 4.33 VAV SOX SPACE 19 A ?0 1 1 17 C18 I VAV-8-111 (3KW HEAT )COMB 3.53 VAV BOX SPACE B2 1 1 19 A 20 1 SPARE SPACE PA S GE 23 C i 24 1 21 1 B 22 SPACE. SPARE SPA• $ CE GE SPACE----_..----•----�------•-----•----•---._...:_-•- _- ----- 25 -.._... .----_ --------- 1 ----••-•-•--�-- C 24 -•----•- 1 -•------.... _-_ -__-_ -_.___._._----._...._.._.__....-------•--------•-------------------•------•-•----•- SPACE SPARE 27 8 F 28 1 1 25 A 26 1 DUCT HEATER ----------•------------... .---•-----•---------•-------...._-------------.._._._.._.-------•---•-------... MISC 3.00 SPACE�---.-_ SPARE 29 ----------- C , 30 --------- 1 -__._... 1 27 B _ 28 1 BATH HEATER SPACE SPARE1 31 A 32 1 29 C 30 1 SPARE SPACE SPARE 33 B 34 1 1 31 A 32 1 SPARE SPACE SPACE 35 C 38 1 33 B . 34 1 SPACE LIGHTING • ROOMS 620_8, 6211, 6212 ---- LTG SPACE SPACE 1 37 A 1 35 C 36 1 LTG LIGHTING - ROOMS 6209, 6210 LIGHTING - ROOMS 6216,6217, 6218, 6219, 6220.6221 SPACE SPACE 20 1 39 1 37 A 38 3 20 SPACE VAV BOX SPACE 1.70 20 1 1 39 8 40 - - - SPACE LOAD SUMMARY: LOAD TYPE CONNECTED EIA D. CALCULATED 1....... 41 . C . 42 - - CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35,25%) - ESTIMATED MAXIMUM DEMAND (EMD)CALCULATIONS PHASE A: 16.63 KVA 81 AMPERES SMALL APPLIANCE RES am) (CVA 0.00 KVA (100/35/25%) LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED ^ _.._-----•-•--__-..._ PHASE B: 24.56 KVA 89 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) LIGHTING LTG 7.10 KVA 888 KVA (125%) PHASE 0: 17.63 KVA 63 AMPERES REMAINING MOTORS MTR 26.33 KVA 26.33 KVA (100%) CONNECTED PHASE LOADING RESIDENT LIG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) GEN PURPOSE RECPT REC 0.40 KVA 0.40 KVA (50%>1 OKVA) PHASE A: 16,63 KVA 61 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE B: 24.56 KVA 89 AMPERES LARGEST MOTOR (CVA 0.00 KVA (125%) EQUIP/OTHER MISC 0.00 KVA 0.00 KVA (100%) PHASE C: 17.63 KVA 63AMPERES REMAINING MOTORS MTR 26.33 KVA 26.33 KVA (400%) HEATING MISC 24.99 KVA 24.99 KVA (100%) GEN PURPOSE RECPT REC 0.40 KVA 0.40 KVA ( 50% > 10KVA) ELEVATOR (0 Total] ELEV 0.00 KVA 0.00 KVA (1:00%) COMPUTER REC PT MISC 0.00 KVA 0,00 KVA (100%) GENERAL NOTES: 0.00 KVA (100%) EQUIP/0T11ER MISC 0.00 KVA 0.00 KVA (100%) 1 60.60 KVA HEATING MISC 24.99 KVA 24.99 KVA (100%) i FLAG NOTES: ELEVATOR [0 Total] ELEV 0.00 KVA 0.00 KVA (100%) i 1 KITCHEN Ef [0 Total] KITCH 0.00 KVA 0.00 10/A (100%) LOAD TYPE NOTES; TOTALS 58.82 KVA 60.80 KVA FLAG NOTES: 71 AMPS 73 AMPS 1 LOAD TYPE NOTE'S: "MMSC"= EQUIP, COMPUTER RED OR HTG LOAD ON INDICATED CIRCUIT AT 100% "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "REV= RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MSC" -= EQUIP, COMPUTER RED OR HTG LOAD ON INDICATED CIRCUIT AT 100% PANEL SCHEDULE PANEL: HV AMP: 400 MW Q] MCB [] TYPE: EXISTING [a NEW [l LOCATION: ELECTROOM LEVEL 1 STYLE; x7501 VOLTS: 480 Y/277V P: 3 AIC RATING: c••SEE RISER DIAGRAM MOUNT: SURFACE 0 FLUSH NEUTRAL: 100% W: 4 DISTRIBUTION:( NO ] FED FROM: MAIN DISTRIBUTION PANEL CIRCUIT DESCRIPTION LOAD TYPE LOAD CKT KVA BKR P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION BATHROOM HEAT 201 155KVA TRANSFORMER TO PANEL ATRIUM COMB 2.83 30 2 #1 LIEIT HEATER FIRST FLOOR #3 (1NI HEATER FIRST FLOOR #2 UNIT HEATER 1ST FLOOR #4 UNIT HEATER 1ST FLOOR COMB 3.74 - - MISC,..._ 3.33'.,...... 20 ..,......3 MISC 3.33 - - ....9. MISC 3.33 -- 11 MISC5.67__.__`30 _...__3.._.._ 13, MISC..... .§A7 . ........ - ........._ .........1S 1 3 5 7 MISC 5.67 - - MESC 5.67 30 - 3 MSC 5.67 _�. - - MISC 5.67 - - MSC 5.67 30 MISC MISC 5.67 17 19 21 23 25 27 5,67 - 2$ SPARE 100 .....3....- ... 31 - 33 "_......................... ..._.._.._..._.._........_.,.. :.......... 35 SPACE 3 37 E. . - 39 - - 41 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LIGHTING RESIDENT LTG/RECPT SMALL APPLIANCE LARGEST MOTOR REMAINING MOTORS GEN PURPOSE RECPT COMPUTER RECPT EQUIP/OTHER t-1EATING ELEVATOR [0 Total) KITCHEN EI (0 Total] TOTALS LOAD TYPE CONNECTED E.M.D. CALCULATED LTG RES RES MTR REC MISC MISC MSC ELEV KITCH 4.70 KVA 0.00 KVA 0.00 KVA KVA 0.00 KVA 1.67 KVA 0.00 KVA 0.00 KVA 144.22 KVA 0.00 KVA 0.00 KVA 150.79 KVA 181 AMPS 5.88 KVA (125%) 0.00 KVA (100/35/25%) 0.00 KVA {100/35125%) 0.00 KVA (125%) 0.00 KVA (100%) 1.87 KVA (50%> 10KVA) 0.00 KVA (100%) 0-00 KVA (100%) 144.22 KVA (100%) 0.00 KVA (100%) 0-00 KVA (100%) 151.97 KVA 183 AMPS LOAD TYPE NOTES: "COMB'= COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC"= EQUIP. COMPUTER REC OR HTG LOAD ON INDICATED CRCUITAT100% 3 30 4.33 MISC FACULTY AREA. DH '3` EAST ENE, 4 - - 4.34 MC 6 -- 4.33 MISC - 8 3..,... 30 4.33. MISC DH 7 2ND FLOOR C s 12 - - 4.33 MISC - 14 3 305.67 MSC DH TE 2ND FLOOR 13 ... 16._..........�......._...,,..... 5,67MiSC -la - - - 557 -..._ MSCA _............3......._,40 7.33'... MISC B 22 - 7.33 MISC 24 - - 7.33 M€SC OH '9' 214[7 FLOOR `-- -- 26 3 40 6.08 MSC ATRIUM A/C & HEAT. 10 TON UNIT -ROOF a I 28 6.08 MISC 30 - - 6.08 MISC A. 32 3 SPACE 34 - - 36 _ 38 3 SPACE. 40 42 CONNECTED PHASE LOADING PHASE A: 46.07 KVA 173 AMPERES PHASE B: 50.91 KVA 184 AMPERES PHASE C: 51.81 KVA 187 AMPERES GENERAL NOTES: 1 FLAG NATES: 1 PANEL SCHEDULE PANEL: LB LOCATION: ELECT ROOM LEVEL 2 VOLTS: 480 Yi277V P: ANP: 100 MLO ID MCB 0 AIC RATING: -SEE RISER DIAGRAM TYPE: EXISTING 0 NEW [] STYLE: 14551 NEUTRAL: 100% DISTRIBUTION: 3 IN: 4 MOUNT:'][X SURFACE 0 FLUSH - NO 1 FED FROM: PANEL LA CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT SKR P CR # P CIR /I d # P CKT SKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION SPACE _.___.. 1 A 2 20 _...3..2p.._.. MTR AC -8-1 SPACE 3 B 4 -3_... - - 3.20 _ _ MTR - SPACE5 C 6 - - 320 MTR - SPACE 7 A e 83 20 2.60 MTR AC -6-2 SPACE - -- -- 9 $ 10----iio -•-•- --• - 2 .60 MTR SPACE 11 C 12 - - 2.60 NUR SPACE . _ 13 A ..14 3 20 .2.80 MTR EDI -1-1 EDIT -2 MISC 4,33 20 3 15 8 16 - - 2,80 N1TR - - MSC 4.33- 17 18 - - 2.80 MTR - - MISC 4.33 - 19 A ?0 1 SPACE VAV-8-111 (3KW HEAT )COMB 3.53 20 121 B2 1 SPACE E SPARE 20 1 23 C i 24 1 SPACE. SPARE 20 1 25 A . 21; 1RED- 20RECWATERHEATS 0.20 F2 DUCT HEATER MISC 3.00 20 1 27 8 F 28 1 20 0.20 REC REC - WATER HEATER DUCT HEATER ----------•------------... .---•-----•---------•-------...._-------------.._._._.._.-------•---•-------... MISC 3.00 20 1 29 ----------- C , 30 --------- 1 -__._... ---•- --------- --------------- SPACE~ .__.__-._._..---•-------._.-_-------•-------•------ -•---------------------- BATH HEATER 20 1 31 A 32 1 SPACE SPARE 20 1 33 B 34 1 20 3.00 DISC DUCT HEATER SPARE 20 1 35 C 38 1 SPACE LIGHTING • ROOMS 620_8, 6211, 6212 ---- LTG 1:80 1.80 20 1 37 A 38 1 20 1.70 LTG LIGHTING - ROOMS 6209, 6210 LIGHTING - ROOMS 6216,6217, 6218, 6219, 6220.6221 LTG 1.90 . 20 1 39 B P. 40 1 SPACE LIGHTING - ROOMS 62255, 6213, 6214 LTG 1.70 20 1 41 C 421. S PAC 5 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE CONNECTED EIA D. CALCULATED LIGHTING LTG 7.10 KVA 8.88 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35,25%) PHASE A: 16.63 KVA 81 AMPERES SMALL APPLIANCE RES am) (CVA 0.00 KVA (100/35/25%) PHASE B: 24.56 KVA 89 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) PHASE 0: 17.63 KVA 63 AMPERES REMAINING MOTORS MTR 26.33 KVA 26.33 KVA (100%) GEN PURPOSE RECPT REC 0.40 KVA 0.40 KVA (50%>1 OKVA) COMPUTER RECPT MSC 0.00 KVA 0.00 KVA (100%) I GENERAL NOTES: EQUIP/OTHER MISC 0.00 KVA 0.00 KVA (100%) 1 HEATING MISC 24.99 KVA 24.99 KVA (100%) ELEVATOR (0 Total] ELEV 0.00 KVA 0.00 KVA (1:00%) KITCHEN EE [0 Total) KITCH 0.00 KVA 0.00 KVA (100%) TOTALS 58.82 KVA 60.60 KVA i FLAG NOTES: 71 AMPS 73 AMPS i 1 LOAD TYPE NOTES; "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES"= RESIDENTIAL LTWRECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATEDDEMAND "MMSC"= EQUIP, COMPUTER RED OR HTG LOAD ON INDICATED CIRCUIT AT 100% MDP PANEL HV PANEL LA PANEL LB 1LI7 O€" ogo& RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES 1-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 (.0 1 W W ce U5 0 0 VJ LnL L.L. z H 0 U z Z U W ISSUE I REVISIONS REVIEWED FOR COMPLIANCE WITH NFPA701- NEC OCT 2 4 2017 City of Tukwila BUILDING DIVISION Project No.: 15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES E-601 PANEL SCHEDULE PANEL: ATRIUM LOCATION: ELECT ROOM LEVEL 1 VOLTS: 120 /208V P: 1 W: 3 AMP: 80 MLO 0 MCR 0 AIC RATING: <.•SEE RISER DIAGRAM MOUNT: J SURFACE 0 FLUSH TYPE: EXISTING 0 NEW [j STYLE: PONY STYLE NEUTRAL: 100% FED FROM; PANEL 1-h' (via 15KVA xtr4r) 3 LOAD LOAD CKT P CIA P CIA 0 CKT LOAD LOAD CKT CIRCUIT DESCRIPTION TYPE KVA BKR TYPE # H # * SKR KVA TYPE CIRCUIT DESCREPT ION MAIN BREAKER_-••_-- -.__-_--__---__.---- --__.__-- ______ 60 2 1 A -- 2 - 1 - 200.35 1 LTG 1ST FLOOR CAN LIGHTS -- REC -MAIL1FAXICOPY CORRIDOR TRACK LIGHTS LTG - 3 B 4 1 20 0.36 REC REC - 2N0 FLOOR SOFFIT LIGHTS LTG 0.80 20 1 5 A 6 1 20 0.36 REC REC - IN ERIOR CAN LICSHTS LTG 0.91 20 1 7 B 8 1 20 0.54 REC REC - EX7ERIO SOFVITLIGHTS-----.____-__.___-_- LTG 0.35 20 1_._. .. A _i0-__? ._. 20 0.25 REC REC FLOOR ATRUNI LIGHTS LTG . 1.03 _ -- 20 1 _. 11 B 12 1 20 025 LTG OLS ENTRY LIGHTS ATRIUM€ RECEPTACLE LTG Q_54 215 1 Ti- A 14 1 20 1$..... _. __. - ATRIUM RECEPTACLE --- ATRIUM LIGHTLTG 1 0.50 20 1 15 B 16 _ 1 _ __.._ 20 0.18 EEC ATRIUM RECEPTACLE ESTIMATED MAXIMUM DEMAND (EMO) CALCULATIONS 1 20 LOAD SUMMARY: LOAD TYPE: CONNECTED EM.D. CALCULATED __._._..__.._._..-_---•- DOOR ACTUATORS - ENTRY 105 - - LIGHTING LTG 4.70 KVA 5.68 KVA (125%) 1 20 CONNECTED PHASE LOADING RESIDENT LTGIRECPT RES 0.00 KVA 0.00 KVA (100!35128%) REC • DIRECTOR OF STUDENT MANAGEMENT 20 PHASE A: 2.83 KVA 14 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100135/25%) B PHASE B: 3.74 KVA 18 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) 0.90 20 1 REMAINING MOTORS MTR 0.00 KVA 0.00 KVA (100%) C 24 GEN PURPOSE RECPT REQ 1.$7 KVA 1.67 KVA (50% > 10KVA) 20SPARE GENERAL NOTES: COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) REC 1 PER NEC 210.4(A) & (B) ALL MLL.TWRE BRANCH CIRCUITS SHARIIti3 A COMMON NEUTRAL WIRE EQUP1OT} ER MISC 0.00 KVA 0.00 KVA (100%) A MUST BE PROVIDED WITHA MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNEROIJNDED HEATING MISC 0.00 KVA 0-00 KVA (100%) 20 CONDUCTORS AT THE POINT OF ORIGIN CONTRACTOR'S CHOICE • PROVDE SEPARATE NEUTRALS ELEVATOR (0 Total) ELEV 0.00 KVA 0.00 KVA (100%) REC (FURNITURE) -OPEN OFFICE 121 FOR BREAKER AS INDICATED OR PROVDE MULTIPOLE BREAKER FOR SHARED NEUTRAL. KITCHEN Er [0 TataI) KITCH 0.00 KVA 0.00 KVA (100%) 1 27 B 26 1 FLAG NOTES: TOTALS 6.57 KVA 7.75 KVA REC 1 1 32 AMPS 37 AMPS C E01 LOAD TYPE NOTES: 20 O,OS MTR EF -1 . RESTROOM 132 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 20 2 "RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND A -...._. _.._ 32 "MSC" n EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100% 20 _------- ------•-----... 1.60 LTG E601.DWG 9/14/2017 5:09 PM PANEL SCHEDULE PANEL: pm AMP: 200 MLO [} MOB [] TYPE: EXISTING Ea NEW 0 -CIRCUIT DESCRIPTION LOCATION: ELECT ROOM LEVEL 1 STYLE: >nooc LOAD TYPE LOAD CKT KVA W R P VOLTS: AIC RATING: NEUTRAL.: 100% 208 Y/120V P: 3 W: 4 -'--SEE RISER DIAGRAM MOUNT: 0 SURFACE 0 FLUSH DISTRIBUTION: 1---Fltri FED FROM: MAIN DISTRIBUTION PANEL CIR P CIR P it # CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION PANEL PA2 REC -WAITING 106, RECEPTION 107A, ADMIN 1076 REC • EVAITINQ 106, WALL MONITOR REC.:- MEETING ROOM1070 REC -ADMISSIONS„ REC -ADMISSIONS REC - NW REQ - NW FACP ENTRANCE FLOOD LIGHT _.._ MECHANICAL ROOM DRYER REC • MEETING RM, CORRIDOR STATIONS TIE HANDLE REC * memo RMtcORRIDOR STATIONS TIE HANDLE HOT WATER HEATER REC -COMPUTER LAB (NE . WALL) REG -COMPUTER LAB (N.WAL,L,.) REC -COMPUTER LAB (VWJ. WALL) REC -COMPUTER LAB (S,E.WALL) ESTIMATED MAXIMUM DEMAND (E MD) CALCULATIONS COMB COMB COMB.... - RC E REC REC "REC'., REC. ._. REC REEL MISC LTG REC REG MISC MIS C REC REC REC REC 11.37 100 8.64 10-13 1.0820 0.36.- 20, 0.S4 20 .. 0.54 20 ....0:36,.,,. 20 0.9020 0,72..,. 20.,.. 0,20 0.12 1.26 1.08 Z25 2.25 0.54 0,72 0.72 0.90 20 20 20 20 20 3 1 3 5 2 4 S 8 1 20 0.90 REC REG - MEETING ROOM 116 1 20 0.54 REC REC - MEETING ROOM 117 1 20 0.64 REC REC • MEETING ROOM 111 1.44 REC REC - MEETING ROOM 112,113 0.72 REC REC • MEETING ROOM 114 _ _ C _ REC - CONFERENCE ROOM 118 018 REC REC - CORRIDOR 7 A 1........ 20 120 1- 201 20 11 C 12 I .. 13 A 14'. 30 20 20 20 20 1 .. 1 1 2 15 3 16 1 20 t 1.20 REC REC (PRINTER) • ADMIN AREA 107E 17 C 18 1 20 0.72 REC REC - PERIMETER EAST „ 0 ,,,..�.,. ,,. 20 „ ,.0.72.., , ."'REQ ' LEG _..PESTER NORTH 19 A 21 #3 23 25 A 27.. 13 29 �C 31 ..,.. A33 ... B 35 1 C 37 A 39 B 1 20 24 1 20 26...... 1 _._ 20 28 1 20 30 1 20 32 1 20 34 120 36 1 15 38 .....,.. 1 20 0.20 REC REC MECHANICAL, RESTOOM, & IRRIGATOR 0.15 LTG RESTROOM LIGHTS 0.30 LTG EXTERIOR LIGHTS 0.10 LTG SOFFIT LIGHTS 0.10 LTG SOFFrf LIGHTS 1.00 MTR MECHANICAL ROOM COMPRESSOR TIE HANDLE 1.00.__. Mme..__ MECHANICAL ROOM COMPRESSOR TIE HANDLE 0.36 REC FURNITURE RECEPTACLES 0.18 REC REQ - MDF ROOM IN CELING ::.:.. 40 1 20 l 0.18 RE C REC - MDF ROOM IN CEILING 41 Cl) 42 1 20 1 0.18 REC REC - MOF ROOM IN CEILING LOAD SUMMARY: LIGHTING RESIDENT LTGIREECPT SMALL APPLIANCE LARGEST MOTOR REMAINING MOTORS GEN PURPOSE RECPT COMPUTER RECPT EQUIP/OTHER HEATING ELEVATOR [) Tcta11 KITCHEN Er (0 Total) TOTALS LOAD 'NPM LTG ---- RES RES MTR REC MISC MISC MISC ELEV KETCH CONNECTED E.M.D_ CALCULATED 5,62 KVA 7.03 KVA (125%) 0.00 KVA 0.00 KVA KVA 8.26 KVA 33.62 KVA 0.00 KVA 2.44 KVA 5.50 KVA 0.00 KVA 0.85 KVA 5629 KVA 156 AMPS 0.00 KVA (100/35/25%) 0.00 KVA (100135/25%) 0.00 KVA (125%) 8.26 KVA (100%) 21.81 KVA ( 50% > 10KVA) 0,00 KVA (100%) 2.44 KVA (100%) 5.50 KVA (100%) 0.00 KVA (100%) 0.85 KVA (100%) 45.89 KVA 127 AMPS LOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" E. RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" = EOUEP, COMPUTER REC OR HTC LOAD ON INDICATED CIRCUIT AT 100% _..._ CONNECTED PHASE LOADING PHASE A: 21.40 KVA 178 AMPERES PHASE 6: 17.73 KVA 148 AMPERES PHASE C: 17.16 INA 143 AMPERES GENERAL NOTES: 1 BOLD INDICATES NEW OR LOPD MOD FICATIONS. FLAG NOTES: PANEL SCHEDULE PANEL: PA2 LOCATION: ELECT ROOM LEVEL 1 VOLTS: 208 YI120V P: AMP: 100 MLO [X MCB 0 AIC RATING: "-SEE RISER DIAGRAM TYPE: EXISTING El NEW 0 STYLE: ooa NEUTRAL: 100% DISTRIBUTION: 3 W: 4 MOUNT: 0 SURFACE 0 FLUSH FED FROM: PANEL PA1 L NO LOAD LOAD CKT P OR P CIR ' P CKT LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA 8KR * N i SKR KVA TYPE CIRCUIT DESCRIPTION REC - MDF ROOM REC 1.44 20 1 1 A : 2 1 20 0.54 REC REC -MAIL1FAXICOPY CORRIDOR TRACK LIGHTS LTG 1.25 20 1 3 B 4 1 20 1.2!1 MISC REC -COPIER CP CORRIDOR 'TRACK LIGHTS LTG 0.80 20 1 5 C 61,..., _..-20,... _..,0,64 REC REC - MEETING ROOM 123.^ ,.....,.._._..,.. REC - LIBRARY REC 0.90 20 1 7 A 8 1 20 1.08 REC REC • OPEN OFFICE 122 (W- WALL, POWER POLE} REC - LIBRARY --•--•--•-----_--_-__.----•-----.__..-- REC -CORRIDOR REQ.._.,..... REQ 20 0 72_.,...-.9 0.72 20 _._ 1 1 11 B C 1020 12 1 1 - 20 -- - 1.08 "-- --- REC _ REC (CNTRL'D)-OPEN OFFICE 122 - .WALL - -I Q TY_:....(W , POWER -Foil REC -ADJUNCT FACI.ETY REC - FACULTY LOUNGE ...,,.......:..,_. ..._.,....._,.,.....,....,..,_..,..., .,_..._....._.....,......- REC 0.36 20 1 13 A 14 1 20 REC -ADJUNCT FACILITY REC - REFRIGERATOR, TV KITCH 0.85 20 1 15 B 16 1 20 0.90 REC REC -OPEN OFFICE 122(E, WALL) REC - FACULTY LOUNGE REC 0,54 20 1 17 1 20 0.90 REC -- - REC (CNTRL O) -OPEN OFFICE -;122 E. WALL) C 18 REC-S GE PUMP20ADA UR -----...----••----•-•--._...------ MTR 1.20 ---- ------•----------- 1 19 A 20 1 20 0.50 MISC DOOR ACTUATORS - ENTRY 105 - - 22 1 20 SPARE REC • DIRECTOR OF STUDENT MANAGEMENT 20 1 21 B REC -OPEN OFFICE 121 (N. WALL) REC 0.90 20 1 23 C 24 1 20SPARE REC (CNTRL'D)- OPEN OFF ICE 121(N.WALL) REC 0.90 20 1 25 A 26 1 20 SPARE REC (FURNITURE) -OPEN OFFICE 121 REC 1.08 20 1 27 B 26 1 20 SPARE REC (FURNITURE) CNTRL'D -OPEN !OFFICE 121 REC 1.08 20 1 20 C E01 20 O,OS MTR EF -1 . RESTROOM 132 ACS -1 -I -FAN 20 2 31 A -...._. _.._ 32 ._._._.._...._.._.._.._. 1 20 _------- ------•-----... 1.60 LTG .---------------......_._.__-.__..--------------•--------- CORRIDOR TRACK LIGHT - -------•----------•--- -----------_-- .---- - - 33 . B 34 1 20 1.20 LTG CORRIDOR TRACK LIGHT AC6-1-1-CONDENSOR ,..,..,,............_........,..._..,_,.....,......,..,... ..,_..........._...-_,._ MTR .........,..... 2.49 30 ,...,_.,,........ _...,.,,,..........___ 2 35 ..__...._._:.. C 36 1 _......-..�......,.. 20 0.36 REC REC-TELECOM 131 .........................._...._... - MTR 2,49 - -37 A 30 1 20 4,35 IREC REC TELECOM 131 REC • VP FINANCE ....,......_.._.........,......_...,.........................._.-.........,...............:.. 20 1 39 B , 40 1 20 0.36 ....,..............:...._ REC - REC -TELECOM 131 REC •STOR. RESOURCES 120, (PRINTEE) OPEN OFFICE 12' COMB 0,72 20 1 41 C 42 1 20 1.00__Y MISC OUTSIDE HEAT TAPE. _ __ -------_--_________ ESTIMATED MAXIMUM DEMAND (ER/ID) CALCULATIONS LOAD SUMMARY: LOAD TYPE CONNECTED EMI). CALCULATED LIGHTING LTG 4.85 KVA 6.06 KVA (125%)_ CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0,00 KVA 0.00 KVA (100/35/25%) PHASE A: 1137 KVA 94 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100135/25%) PHASE B: 8.64 KVA 71 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) PHASE C: 10.13 KVA 84 AMPERES REMAINING MOTORS MTR 6,26 KVA 626 KVA (100%) GEN PURPOSE RE.CPT REQ 14.94 KVA 12.47 KVA (50% > 10KVA) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) GENERAL NOTES: EQUIP/OTHER MSC 2.24 KVA 224 KVA (100%) 1 BOLD INDICATES NEW OR LOAD MODIFICATIONS HEATING MISC 1.00 MIA 1.00 KVA (100%) ELEVATOR [0 Total] ELEV 0.00 KVA 0.00 KVA (100%) KITCHEN EI (0 TOME) }DITCH 0.85 KVA 0.85 KVA (100%) TOTALS 30.14 KVA 28.88 KVA. FLAG NOTES: 84 AMPS 80 AMPS 1 LOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES`= RESIDENTIAL LTG/RECPT ORSMALLAPPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" = EOUIP, COMPUTER REC Of HTC LOAD ON INDICATED CIRCUIT AT 100% PANEL ATRIUM PANEL PA1 - PANEL PA2 RECEIVED CITY OF TUKWILA OCT 13 2011 PERMIT CENTER FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES I-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223.6446 Seattle, Washington 98104 fax: (206)223.6465 TENANT IMPROVEMENTS V 0 m 00 00 CeQ I.,LI O� ID z1-1 Q Ln ISSUE / REVISIONS REVIEWED Oh COMPLIANCE WITH NPPA 70 - NEC OCT 2 4 2011 City of Tulip t BUILDING DIVISLQ. Project No.15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES (2) E-602 PANEL SCHEDULE PANEL: PB3 LOCATION: ELECT ROOM LEVEL VOLTS: 208 10120V P: AMP: 40 MLO ED MCS 0 AIC RATING: .c --SEE RISER D',ADRAM TYPE: EXISTING ® NEW 0 STYLE: mot NEUTRAL: 100% DISTRIBUTION; 3 W: 4 MOUNT: j SURFACE i_l FLUSH FED FROM: PANEL PSI NO I NO LOAD LOAD t:K1' P CIR i P CIR P CKT LOAD LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA BKR BER 7k ;r H * H # BKR KVA TYPE CIRCUIT DESCRIPTION - ---- - ----- ______ ___ ____------•___ HVAG TRANSFORMER REC - HAIL. MEETING ROOM 206 __----- -- - 20 - � -- _ - 1 A - -- ... 2 .. --_20 1 20 0,40 RE - - - - - -- - REG - ROOM 62T3--- REC - CORRIDOR +8211, ROOM 6210 REC 0.70 20 1 3 ...__ 4 ......_ _... ...... 20 5D __. ..._..., REC - ROOMS 6214 6215 -_--•__-- E C - Rooms 0210, 6213 REC . 0.90 20 1 5 C S 1 20 0.90 ITEC REC-CLASSROOMS 'B' 208, CLASSROOM 'CZ. 211 PROJECTOR - ROOMS 6x13, 6214 REC 0.36 20 1 7 A 8 1 20 0.40 REC REC - ROOMS 6210, 6214 REG -OPEN OFFICE 216 (S_8, E_ WALL)_ 0.72 126 20_ 1 9 B 10 20 20-_ 0.50 LTG LIGH_T1NG -SE STAIRS - REC (CAITRD) - L OPEN OFFICE A 216 (S. E. WALL} - _REC-. REC _ _ 1.26 _ 20 .__ 1 _ 11 1 C - ___•. 12 ____I ___ 1 20 -- -- 0.50 LTG LIGHTING - SOUTH -SIGN ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 1.50 REC LOAD SUMMARY LOAD TYPE: CONNECTED E.M.D. CALCULATED A 14 1___ LIGHTING LTG 1.00 KVA 1.25 KVA (125%) 20 REC CONNECTED PHASE LOADING RESIDENT LTGIRECPT RES 0.00 KVA 0.00 KVA (100/35425%) ____0.80_20 REC 0.90 20 PHASE A: 1.16 KVA 10 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA 000135125%) B 16 PHASES: 2.96 KVA 24 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) _0.72 0.72 PHASE G: 3,56 KVA 29 AMPERES REMAINING MOTORS MTR 0.00 KVA 000 KVA (100%) REC -MEETING RMS 206, 207 REC GEN PURPOSE RECPT REC 6.68 KVA 6.68 KVA (50% > IORVA) 1 17 COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) 18 GENERAL NOTES: 20 EQUIP/OTHER MISC 0.00 KVA 0,00 KVA (100%) 20 1 BOLD INDICATES NEW OR LOAD MODPOATIQNS HEATING MISC 0.00 KVA 0.00 F(VA (100%) 1.08 20 1 ELEVATOR (0 Total) ELEV 0.00 KVA 0-00 KVA (100%) . A 20 KITCHEN El p Total) KITCH 0.00 KVA 0.00 KVA (100%) 0.36 REC TOTALS 7.68 KVA 7.93 KVA LTO FLAG NOTES: 1 21 AMPS 22 AMPS ' B 22 1 20 LOAD TYPE NOTES: REC REC - MEETING ROOM 202 "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT LTG 0.70 20 "RES"= RESIDENTIAL LTG/REC PTORSMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND 23 C - 24 "MISC" = EQUIP, COMPUTER REC OR HTO LOAD ON INDICATED CIRCUIT AT 100% 20 1.62 0: \PROJECTS\2017 PROJECTS\17030 - OCHS WORKSOURCE (WJA)\CADD\17030 - E601.DWG 9/14/2017 5:09 PM PANEL SCHEDULE PANEL: PB2 LOCATION: ELECT ROOM LEVEL 2 VOLTS: 208 '+?120V P: 3 W: 4 AMP: 100 MLO ED MCB L._I AIC RATING; <-SEE RISER DIAGRAM MOUNT: [ SURFACE 0 FLUSH PANEL: PBI LOCATION: ELECT ROOM LEVEL VOLTS: 208 Y11201/ P: AMP: 200 MLO CI MCB Ej AIC RATING: <-SEE RISER DIAGRAM TYPE: EXISTING ® NEW 0 STYLE: iaoot NEUTRAL: 100% DISTRIBUTION: 3 W: 4 MOUNT: jJ SURFACE 0 FLUSH FED FROM: MAIN DISTRIBUTION PANEL M0 T-6) I NO LOAD LOAD LOAD CRT P CIR p CiR P CET LOAD LOAD CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION TYPE EVA BER ! II- H # DER EVA TYPE CIRCUIT DESCRIPTION REC - HAIL. MEETING ROOM 206 REC . 0.54 20 I 1 A 2 1 20 0.20 REC REC - CLASSROOM 'A' 225_ REC -RESOURCES AND COMPUTERS 209 • REC 0.72 20 1 3 S . 4 1 20 020 REC REC - CLASSROOM W 225 REC -RESOURCES AND COMPUTERS 201 REC 0.72 20 1 5 C 6 1 20 0.20 REC REC -CLASSROOM'A'225 UGHTfi NW STAIRS LTG 0.50 20 1 7 A 8 1 20 0.50 REC PROJECTOR - CLASSROOM 'A' 225 REC - MEETING ROOMS 202, 703 REC 0.72 20 1 9 B 10 1 20 1.20 MISC REC (PRINTER) - SECURE OPEN OFFICE 216 REC-WELi.NESSR00M 227 REG 0.54 2-0 1 11 C 12 1 20 ..-0.72'-- --REC REC-WEST WALL OPEN OFFICE------ UGI-TE G_SAIEVELECTRICROOMS LTG 1.50 REC 13 A 14 1___ 20 20 REC 13 -_______ REC -CLASSROOM B 208. MEETING RM 202 ____0.80_20 REC 0.90 20 -1--- 1 -•- 15 B 16 1 _ 20 _0.72 0.72 - REC - _PORN_ITU_RE(CONTROLLED)-CENTRALOPENOFFICE FURNITURE -CENTRAL OPEN OFFICE - REC -MEETING RMS 206, 207 REC 0.72 20 1 17 C 18 1 20 20 SPARE REG - CLASSROOM A' 225, MTG 215, OPEN OFFICE 216 REC 1.08 20 1 19 . A 20 1 20 0.36 REC REC - MEETING ROOMS 202,203 LIGHTING -OUTSIDE SOFFIT LTO 0.70 20 1 21 ' B 22 1 20 0.36 REC REC - MEETING ROOM 202 LIGHTING -OUTSIDE SOFFIT LTG 0.70 20 1 23 C - 24 1 20 1.62 REG FURNITURE (CONTROLLED) -CENTRAL OPEN OFFICE EF- SA -11-1 MTR 0.50 20 1 25 A ' 26 1 20 0.90 REC FURNITURE -CENTRAL OPEN OFFICE REC -RECEPTION 203, WALL MONITOR, MTG. RM 204 REC 1.08 20 1 27 B 28 1 20 0.72 REC FURNITURE -CENTRAL OPEN OFFICE REC -IT CLOSET 226 RE C0.72 20 1 29 C 30 1 20 281 SPARE REC_ IT CLOSET 226 REC 0.72 20 1 31 A 32 3 100 12.04 COMB PANEL PB2 REC -IT CLOSET 226 REC 0.72 20 1 33 8 34 - - 10.86 COMB � REC-CLASSROOMB208(N.€ LSV.-vvALLS) REC 1.08 20 1 35 C s_ 36 _ - - 0.8.72 COMB ------- -------- PANEL PB3 REC -CLASSROOM B 208 (E. WALL) REC 1.08 20 1 37 A 1 38 3 110 1.16 REC REC -CLASSROOMS 208 {S.E. WALLS} -CLASSROOMB208(W. WALL) REG REC 1.08 20 0.72 20 1 11 39, 41 8 40 C 42.........- --•-- 2.96 - 3.56 _ COMB _. COMB -REG ESTIMATED MAXIMUM DEMAND {EMD) CALCULATIONS HALLWAY 62ISTRACK LIGHTING LTG 1,10 21) LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED 37 A 36 LIG!-1TI NG LTG 5.90 KVA 7.38 KVA (125%)__ 20 CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES 0.00 KVA 0.00 KVA (100/35/25%) 20 1 - PHASE A: 21.10 KVA 176 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) 40 1 PHASE 9: 22.94 KVA 191 AMPERES LARGEST MOTOR KVA 0.00 KVA (125%) REC FURNITURE • OPEN OFFICE 218 PHASE C: 20.02 KVA 166 AMPERES REMAINING MOTORS MTR 0.50 KVA 0.50 KVA (100%) 0.50 20 1 GEN PURPOSE RECPT REC 47.36 KVA 28.68 KVA (50%> 10KV A) C 42 1 COMPUTER RECPT MISC 0.00 KVA 0.00 10/A (100%) 1.08 GENERAL NOTES: FURNITURE CONTROLLED OPEN OFFICE 21S EQUIP/OTHER MISC 10.30 KVA 10.30 KVA (100%) 1 BOLD INDICATES NEW OR LOAD MOD FICATIONS. (EATING NEC 0.00 KVA 0.00 KVA (100%) ELEVATOR (0 Total] ELEV 0.00 KVA 0.00 KVA (100%) KITCHEN E' (0 Total] KITCH 0.00 KVA 0.00 KVA (100%) LOAD SUMMARY: LOAD TYPE: CONNECTED EM. D. CALCULATED TOTALS 64.06 KVA 46.86 KVA LIGI-1'iINC3• LTG 2.20 KVA 2.75 KVA 125 FLAG NOTES: 178 AMPS 130 AMPS RESIDENT LTGIRECPT RES 0.00 KVA 0.00 KVA (100/35/25%) 1 PHASE A: 12.04 KVA 100 AMPERES LOAD TYPE MOTES: PHASE B: 10.86 KVA 90AMPERE S LARGEST MOTOR KVA 000 KVA (125%) "COMB"= COMBINATION LOAD TYPES ON INDICATED CIRCUIT REMAINING MOTORS MTR 0.00 KVA 0.00 KVA (100%) . GEN PURPOSE RECPT REC 20,32 KVA 15.16 KVA (50% > 1 OKVA) `RES" = RESIDENTIAL LIG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) "MISC" = EQUIP. COMPUTER REC OR t TG LOAD ON INDICATED CIRCUIT AT 100% EQUIP/OTHER MISC 9.10 KVA 9.10 KVA (100%) PANEL SCHEDULE PANEL: PB2 LOCATION: ELECT ROOM LEVEL 2 VOLTS: 208 '+?120V P: 3 W: 4 AMP: 100 MLO ED MCB L._I AIC RATING; <-SEE RISER DIAGRAM MOUNT: [ SURFACE 0 FLUSH TYPE: EXISTING ID( NEW ID STYLE: ia:ot NEUTRAL: 100% DISTRIBUTION:), NO I FED FROM: PANEL PB1 LOAD LOAD CKT P CER P CRP CET LOAD LOAD CIRCUIT DESCRIPTION TYPE KVA BKR ! 1 H ilt BKR KVA TYPE CIRCUIT DESCRIPTION REC - ROOM 6222.6216,6223 REC 0.90 20 1 1 A 2 1 20 0.50 REC REC - ROOM 6216 REC - ROOM 6222 REG 0.40 20 1 3 B 4 1 20 0.40 REC REG - ROOM 6216 REC - ROOM 6216 (MAI) REC 0.40 20 1 5 C 6 1,.,.. 20 0.54 REC FURNITURE -NORTHEAST OPEN QF FILE COPIER ROOM 6216 MISC 1.50 20 1 7 A 8 1 20 0.54 REC FURNITURE - NORTHEAST OPEN OFFICE REC - ROOM 5225 REC 0.40 20 1 9 B 10 1 20 1.08 REC I FURNITURE (CONTROLLED) -NORTHEAST OPEN OFFICE PRO,IE CTOR ROOM 6225 MISC 0.50 20 1 11 C 12 1 20 1.50 REC FEC - ROOM 6224 REC (DEDICATED) PRODUCTION PRINTER MISC 1.65 20 2 13 A 14 1 20 0.40 REC REG - ROOM 6224 COUNTER GFI - MISC 1.65 - - 15 B 16 1 20 0.70 REC REG - ROOM 6224, 6225 SPARE 20 1 17 C 18 . 1 20 0.40 .,...,REC REC - ROOM 6210...............:.................................:............................... C - ROOM 6219 6220FURNITURE RE 62211 REC 0.90_ 20 19 A 20 1 20 1.08 REC - WEST OPEN OFFICE -RE-O--:ii-da-vi-6:2-ii -- - - REC 0.40 20 1 21 B 22 1 20 - 1.08 • REG _ _ ___ _ ___ __ _ FURNITURE CONTROLLED -WEST OPEN - F E -- ( ) 9F EC REC - ROOM 6216 REC 0.20 20 1 23 C 24 1 20 SPARE REC - ROOM 6217.6218 REC 0.70 20 1 25 A 26 1 20 0.72 REC FURNITURE . WEST OPEN OFFICE REC - ROOM 6217,6211E6219 REC 0.90 20 1 27 B 281 20 0.72 REC FURNITURE (CONTROLLED) - WEST OPEN OFFICE REC - ROOM 6219.8 1220.6221 EC 0.70 20 1 29 C 30 r 1 20 SPARE REC {DEDICATED) PRODUCTION PRINTER2 MISC .,....,.#__.....,..,.....•,... �.....-.._.._.._.........,.......:..:_.....,._...................._..-.._...........S......... 1.6520 31 A � 1 ....... _......... 20 ... 0.40 .,. REC .... REC - ROOMU3C LIGHTING ROOM 6224 .. ..... ...........,........._.,...........,..,,....,,................._._..... • MISC 1.66 - " 33 B 34 1 20 0,40 REC FI=G - ROOM 6206, 6208 HALLWAY 6215 TRACK LIGHTING LTO 1.10 20 1 35 C 36 1 20 1.80 REC REC - PLOTTER ROOM 6212 HALLWAY 62ISTRACK LIGHTING LTG 1,10 21) 1 37 A 36 1 20 SPARE SPARE 20 1 39 B 40 1 20 1.03 REC FURNITURE • OPEN OFFICE 218 ADA 0O0R ACTUATOR -ENTRY 209 JVOSC 0.50 20 1 41 C 42 1 20 1.08 REC FURNITURE CONTROLLED OPEN OFFICE 21S ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTED EM. D. CALCULATED LIGI-1'iINC3• LTG 2.20 KVA 2.75 KVA 125 CONNECTED PHASE LOADING RESIDENT LTGIRECPT RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE A: 12.04 KVA 100 AMPERES SMALL APPLIANCE RES 0.00 KVA 0.00 KVA (100/35/25%) PHASE B: 10.86 KVA 90AMPERE S LARGEST MOTOR KVA 000 KVA (125%) PHASE C: 8.72 KVA 73 AMPERES REMAINING MOTORS MTR 0.00 KVA 0.00 KVA (100%) . GEN PURPOSE RECPT REC 20,32 KVA 15.16 KVA (50% > 1 OKVA) COMPUTER RECPT MISC 0.00 KVA 0.00 KVA (100%) GENERAL NOTES: EQUIP/OTHER MISC 9.10 KVA 9.10 KVA (100%) 1 001.0 INDICATES NEW OR L014) MODFICATIQNS HEATING MLC 0.00 KVA 0.00 KVA (100%) ELEVATOR (0 Total] ELEV 0.00 KVA 0.00 KVA (100%) KITCHEN EI (0 Total] KETCH 0.00 KVA 0.00 KVA (100%) TOTALS 31.62 NOVA 27.01 KVA FLAG NOTES: 88 AMPS 75 AMPS 1 LOAD TYPE NOTES: "CLIMB" _ COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIALLTGIRECPTORSMALLAPPLIANCE LOAD TAKEN AT INDICATED DEMAND "MISC" = EQUIP, COMPUTER REC OR I-ilG LOAD ON INDICATED CIRCUIT AT 100% PANEL PB3 PANEL PB1 - PANEL PB2 Li10 dos RECEIVED CITY OF TUKWILA OCT 13 2017 PERMIT CENTER FINAL ISSUED FOR CONSTRUCTION -SEPTEMBER 14, 2017 King County Department of Executive Services Facilities Management Division Capital Planning & Development King County Administration Bldg. 500 4th Avenue, Room 820 Seattle, WA 98104 Tel. 206.477.9367 design collaborative 119 South Main St, Suite 400 Seattle, WA 98104 Tel. 206.946.9746 www.wja-dc.com EXPIRES I-17-18 BrN Engineering, Inc. Electrical Consulting Engineering 210 3rd Avenue S., Suite 2C tel: (206)223-6446 Seattle, Washington 98104 fax: (206)223-6465 Cf) F- (LU w V z w 0 0 ( 1^.{.. z z p 1-il U z . Z U w E- 0 0 J Ca W W CY d OO a W O� 0 z F-1 ILn ISSUE / REVISIONS li) %it, REVIEWED_ COMPLIANCE WITh NFPA 70 NEC OCT 2 4 2017 City of -Tukwila BUILDING DIVISION Project No.:15032-17ZA Site No.: Drawn By: SH/TD Checked By: BB Sheet Title PANEL SCHEDULES (3) E-603