HomeMy WebLinkAboutPermit EL17-0862 - WOWRACK - UPS REPLACEMENTWOWRACK
12201 TUKWILA INTL BLVD
BLDG B
EXPIRED 05/08/18
ELI 7-0862
)City of Tukwila
Parcel No:
Address:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL PERMIT
0923049120 Permit Number: EL17-0862
12201 TUKWILA INTL BLVD BLDG B
Project Name: WOWRACK
Issue Date:
Permit Expires On:
11/9/2017
5/8/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
INTERNATIONAL GATEWAY WEST
12201 TUKWILA INTERNATIONAL BL,
SEATTLE, WA, 98168
MATT BENDER
18133 NE 68TH ST, D-120 , REDMOND,
WA, 98052
PRIDE ELECTRIC INC
18133 NE 68 ST, STE D120 ,
REDMOND, WA, 98052
PRIDEEI077DR
!I,
Phone: (425) 454-3665
Phone: (425) 454-3665
Expiration Date: 3/19/2019
DESCRIPTION OF WORK:
(2) UPS REPLACEMENT AND ASSOCIATED GEAR PER PLAN -JOB #50394
Valuation of single family: $0.00
Valuation of mf/comm: $43,000.00
Type of Work: TENANT IMP
Fees Collected: $1,134.73
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 20
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
Date:
2014
2014
2014
2015
('`
n
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit. t /�/
Signature: � �/G Date: I 1 `� I 0
Print Name: rf /t/yAye '1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS***
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKW�1
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Electrical Permit. No.
Project No.
- 3 D l
Date Application Accepted: _ l
Date Application Expires:
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
Site Address: 12201 Tukwila International Blvd
Tenant Name: WOWRACK
PROPERTY OWNER
Name: Matt Bender
Address: 18133 NE 68th St, D-120
Name:
Phone: (425) 454-3665 Fax: (425) 497-8700
Email: mbender@prideelectric.com
Address:
City:
State:
Zip:
CONTACT PERSON -person receiving all project
communication
Name: Matt Bender
Address: 18133 NE 68th St, D-120
City: Redmond State: WA Zip: 98052
Phone: (425) 454-3665 Fax: (425) 497-8700
Email: mbender@prideelectric.com
King Co Assessor's Tax No.:
Suite Number: Floor:
New Tenant: ❑ Yes ® .. No
ELECTRICAL CONTRACTOR INFORMATION
Company Name: Pride Electric, Inc.
Address: 18133 NE 68th St, D-120
City: Redmond State: WA Zip: 98052
Phone: (425) 454-3665 Fax: (425) 497-8700
Contr Reg No.: PRIDEEI077DR Exp Date: 03/19/2019
Tukwila Business License No.;
Valuation of Project (contractor's bid price): $ 43,000
Scope of Work (please provide detailed information): (2) UPS replacement and associated gear per plan - Job #50394
Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes m No
Type of Use: COmmercial
Type of work:
❑ New 0 Addition 0 Service Change ® Remodel ® Tenant Improvement
0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service
Property Served by:
El Puget Sound Energy 0 Seattle City Light
W:\Pennit Center \Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised I-I-17.docx
Revised: January 2017
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $155.91
(including an attached garage)
❑ Garages, pools, spas and outbuildings $83.54 ea
❑ Low voltage systems
(alarm, furnace thermostat) $61.05 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
Service change or alteration $83.54
(no added/altered circuits)
Service change with added/altered circuits $83.54
number of added circuits $12.00 ea
Circuits added/altered without service change $55.69
(up to 5 circuits)
Circuits added/altered without service change $55.69
(6 or more circuits) $7.65 ea
Meter/mast repair $69.62
Low voltage systems $61.05
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $66.30
❑ Temporary service (generator) $82.52
❑ Manufactured/mobile home service $87.98
(excluding garage or outbuilding)
❑ Carnivals $82.21
Number of concessions $11.02 ea
Each ride aad generator truck $11.02 ea
***EFFECTIVE JANUARY 1, 2014 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE***
PERMIT APPLICATIONNOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: Matt Bender
Mailing Address: 18133 NE 68th St, D-120, Redmond, WA 98052
W:\Permit Center\Applications-Handouts\Permit Applications \PDFs\Electrical Permit Application Revised 1-1-17.docx
Revised: January 2017
bh
Date:
10/30/2017
Day Telephone: (425) 454-3665
City
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ( ACCOUNT
PermitTRAK
QUANTITY
PAID
$1,134.73
EL17-0862 Address: 12201 TUKWILA INTL BLVD BLDG B Apn: 0923049120 $1,134.73
ELECTRICAL $1,091.09
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$872.87
PLAN CHECK FEE
R000.345.832.00.00
0.00
$218.22
TECHNOLOGY FEE $43.64
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R12686
R000.322.900.04.00 0.00 $43.64
$1,134.73
Date Paid: Monday, October 30, 2017
Paid By: PRIDE ELECTRIC INC
Pay Method: CHECK 7117
Printed: Monday, October 30, 2017 2:30 PM 1 of 1
SYSTEMS
a31N331I1/11HJr!
10/7/2017 0:00
10/7/2017 2:38
10/7/2017 5:16
10/7/2017 7:54
10/7/2017 10:32
10/7/2017 13:10
10/7/2017 15:48
10/7/2017 18:26
10/7/2017 21:04
10/7/2017 23:42
10/8/2017 2:20
10/8/2017 4:58
10/8/2017 7:36
10/8/2017 10:14
10/8/2017 12:52
10/8/2017 15:30
10/8/2017 18:08
10/8/2017 20:46
10/8/2017 23:24
10/9/2017 2:02
10/9/2017 4:40
n 1 10/9/2017 7:18
10/9/2017 9:56
m 10/9/2017 12:34
f '< 73 Pi 10/9/2017 15:12
Z 0 rn 10/9/2017 17:50
m 0 10/9/2017 20:28
ems" -� rn 10/9/2017 23:06
C < m 10/10/2017 1:44
rte^ ? rfl W 10/10/2017 4:22
V10/10/2017 7:00
�= 10/10/2017 9:38
10/10/2017 12:16
10/10/2017 14:54
10/10/2017 17:32
10/10/2017 20:10
10/10/2017 22:48
10/11/2017 1:26
10/11/2017 4:04
10/11/2017 6:42
10/11/2017 9:20
10/11/2017 11:58
10/11/2017 14:36
10/11/2017 17:14
10/11/2017 19:52
10/11/2017 22:30
C\
c
10/12/2017 3:46
10/12/2017 3:46
m
v 10/12/2017 6:32 W
m 10/12/2017 9:10 C 33
CI°
10/12/2017 11:48 rCD m
10/12/2017 14:26 n _:-t .�.. M10/12/2017 17:0410/12/2017 19:42 Z 010/12/2017 22:2010/13/2017 0:58
c
tri
o [ , 0 0 0 0 0
CI
10/13/2017 3:36
10/13/2017 6:14 ` . o� Z m',N
10/13/2017 8:52Ci
ice
10/13/2017 11:30 m
10/13/2017 14:08 a'y
x
1111
10/13/2017 16:46
10/13/2017 19:24
10/13/2017 22:02
L 1
C N
W
N C
8 o a
C l0
Dco
CD
aaewnN eor
M1 paaa1aN
0
0
0
18133 NE 68th Street Suite D-120 Redmond, WA 98052
425-454-3665 WWW.PRIDEELECTRIC.COM
10/7/2017 0:00
10/7/2017 2:38
10/7/2017 5:16
10/7/2017 7:54
10/7/2017 10:32
10/7/2017 13:10
10/7/2017 15:48
10/7/2017 18:26
10/7/2017 21:04
10/7/2017 23:42
10/8/2017 2:20
10/8/2017 4:58
10/8/2017 7:36
c 10/8/2017 10:14
TO 10/8/2017 12:52
10/8/2017 15:30
3 10/8/2017 18:08
10/8/2017 20:46
10/8/2017 23:24
10/9/2017 2:02
10/9/2017 4:40
10/9/2017 7:18
10/9/2017 9:56
10/9/2017 12:34
10/9/2017 15:12
10/9/2017 17:50
10/9/2017 20:28
10/9/2017 23:06
10/10/2017 1:44
10/10/2017 4:22
10/10/2017 7:00
10/10/2017 9:38
10/10/2017 12:16
10/10/2017 14:54
10/10/2017 17:32
10/10/2017 20:10
10/10/2017 22:48
10/11/2017 1:26
10/11/2017 4:04
10/11/2017 6:42
10/11/2017 9:20
10/11/2017 11:58
10/11/2017 14:36
10/11/2017 17:14
10/11/2017 19:52
10/11/2017 22:30
10/12/2017 1:08
10/12/2017 3:46
10/12/2017 6:32
10/12/2017 9:10
10/12/2017 11:48
10/12/2017 14:26
10/12/2017 17:04
10/12/2017 19:42
10/12/2017 22:20
10/13/2017 0:58
10/13/2017 3:36
10/13/2017 6:14
10/13/2017 8:52
10/13/2017 11:30
10/13/2017 14:08
10/13/2017 16:46
10/13/2017 19:24
10/13/2017 22:02
(sdwy) y aseyd luaaanD
(sdwy) 9 maid ;ua.unj-
(sdwy) p aseyd;uaJJnD-
1138Wf1N 9O(
wauro paaaaaW
0
0
0
0
O
m
O
O
0
O
0
O
0
00
O
O
7C r, co fl)QJ 7
C d f"1
7 - Cul O
cu cu
Da co K r'r
co 5
O
c FII
co
M
18133 NE 68th Street Suite D-120 Redmond, WA 98052
425-454-3665 WWW.PRIDEELECTRIC.COM
PERFORMANCE
Bill of Materials
ITEM 1) Eaton Series 9395 — 550kVA with 99% high eff. ESS firmware
(2) 550kVA/500kW Uninterruptible Power System
System Rating: 550kVA/500kW
System Input Voltage: 480VAC, three phase, 3 wire plus G, 60 Hertz
System Output Voltage: 480VAC, three phase, 3 wire plus G, 60 Hertz
Recommended input breaker: 800A 100% rated
(8) Eaton E28 Sealed, valve regulated lead acid (VRLA) Battery Cabinets Runtime:
5 minutes
(2) Wall -Mount MBP solution (2) Breaker 1000A 80% rated 65kAIC, C/w SKRU Key
interlock solution included.
UPS Module shall consist of the following:
— Double Conversion Online (IGBT), 95% efficiency, 99% with ESS firmware
— Lot Redundant Cooling Fans
— Lot Redundant Power Supplies
— Eaton's ABM technology
1 — Operations Manual
1 — Common battery
1 — Xpert SNMP/Modbus TCP/IP Card
1 — Indy Relay card
1 — Seismic brackets for the UPS and battery cabinets
UPS Dimensions:
Battery Dimensions:
MBP Dimensions:
Performance Power Concepts, Inc.
11636 SE 5th Street, Suite 200
Bellevue, WA 98005
Tel: (425) 638-0340/Fax: (425) 638-0341
73.8"W x 32.7"D x 73.6"H, (3,184 lbs.) each
44.3"W x 31.6"D x 74.0"H, (3,250 lbs.) (4 required per UPS)
36"W x 11.3"D x 73.5"H, (700 lbs.) each
REVIEWED FOR
COMPLIANCE WITH
NEPA 70 - NEC
NOV 07 2011
City of Tukwila
BUILDING DIVISION__
A U T 1-1 O R 1 Z E
Representative
4/2/2018
City of Tukwila
Department of Community Development
MATT BENDER
18133 NE 68TH ST, D-120
REDMOND, WA 98052
RE: Permit No. EL17-0862
WOWRACK
12201 TUKWILA INTERNATIONAL BLVD
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 5/8/2018.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 5/8/2018, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
�V1
chelle Ripley
Permit Technician
File No: EL17-0862
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY o
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL17-0862 DATE: 1 0/30/1 7
PROJECT NAME: WOWRACK
SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BLVD
X Original Plan Submittal
Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
`, c U4I7
Building Division i"
Public Works
Fire Prevention
Structural
Ei
Planning Division ❑
❑ Permit Coordinator ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWEROS INITIALS:
DATE: 11/02/17
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 11/30/17
Approved
Corrections Required
❑ Approved with Conditions
❑ Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWERcS INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PRIDE ELECTRIC INC
Home Espanol Contact
Safety & Health Claims & Insurance
Washington State Department of
)Labor & Industries
Search L&I
Page 1 of 3
A -Z Index Help My L&I
Workplace Rights Trades & Licensing
PRIDE ELECTRIC INC
Owner or tradesperson
Principals
GOAD, CHRISTOPHER J, PRESIDENT
GOAD, ROBERT L, VICE PRESIDENT
GOAD, KIRK A, SECRETARY
GOAD, CHRISTOPHER J, AGENT
SEELEY, ROBERT M, PRESIDENT
(End: 03/15/2005)
SEELEY, KAROLYN J, SECRETARY
(End: 03/15/2005)
SEELEY, ROBERT M, AGENT
(End: 03/15/2005)
Doing business as
PRIDE ELECTRIC INC
WA UBI No.
601 451 700
18133 NE 68TH ST D120
REDMOND, WA 98052
425-454-3665
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
...............................................................
Meets current requirements.
License specialties
GENERAL
License no.
PRIDEE1077DR
Effective — expiration
03/19/1993— 03/19/2019
Designated administrator
GOAD, CHRISTOPHER J
License type
Master Electrician
Bond
................
TRAVELERS CAS & SURETY CO
Bond account no.
103366931
Active.
Meets current requirements.
License no.
GOAD*CJ955DG
$4,000.00
Received by L&I Effective date
04/01/2005 03/17/2005
Expiration date
Until Canceled
Savings
No savings accounts during the previous 6 year period.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 11/9/2017
PRIDE ELECTRIC INC
License Violations
0 o
Infraction no.
EMOMJ00691 Satisfied
RCW/WAC
Issue date
11/24/2015
Violation city
REDMOND
Type of violation
ELECTRICAL CITATION
Description
Failing to get an inspection or obtain a valid
electrical/telecommunications work permit or
post a provisional electrical work permit prior
to beginning the electrical/telecommunication
installation or alteration as referenced in WAC
296-46B-901.
Infraction no.
ELY0D00260
Issue date
10/09/2013
Violation city
REDMOND
Type of violation
ELECTRICAL CITATION
Description
Failing to get an inspection or obtain an
electrical/telecommunications work permit or
post a provisional electrical work permit prior
to beginning the electrical/telecommunication
installation or alteration as referenced in WAC
296-46B-901.
19.28.101 RCW
Violation amount
$1,000.00
Satisfied
........._..............
RCW/WAC
19.28.101 RCW
Violation amount
$1,000.00
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
842,543-00
................................
Doing business as
PRIDE ELECTRIC
Estimated workers reported
Quarter 3 of Year 2017 "Greater than 100 Workers"
L&I account contact
T3 / KAYLENE MONIER (360)902-6627 - Email: BRKB235@Ini.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
........................................................
No strikes have been issued against this contractor.
Contractors not allowed to bid
............._..............................................................................
No debarments have been issued against this contractor.
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
Inspection results date
03/09/2012
Inspection no.
315812677
Location
2701 142nd Ave E
Sumner, WA 98390
Violations
Page 2 of 3
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 11/9/2017
LEVEL 3
1Y4"C W/ (3)#3 CU,
1118 CU GND
[2)/2"C W/ 4#4/0 CU
1#4 GND CU
75KVA
T-LR1
LR1
225A
MCB
208V
304W
HL1
225A
MLO
480V
304W
J
4 °
If)
N
N 0
#4cu
LEVEL 2
- 2Y"C, w/4#4/0 CU
1114 GND CU
CL
J
to
N
SBS
800A, 277/480V, 30
EXISTING
(2)SETS OF (4)250 MC AL CABLE
w/ GND
(1) /0 GND 3CU300 CU
REPLACE EXISITNG 800A
BREAKER WITH 1200A
BREAKER
D3
400A
MLO
277/480V
304W
NEW
CC
U)
Li
0
co 0
1000A SPARE
I Iwtw1 1
U)( o U))(0Vim)() ((1)(0
1200A ATS
a
°
U)
m
U)
0
0
0
° W
Ct
a
a
U)
L)--
0
00 2
O N
(V
MDP
2000AF/1200AT
277/480V, 30
EXISTING
ATS -1
1200A
480V
304W
PULL
BOX
ADD (1) PARALLEL FEEDER
TO EXISTING (3) FEEDERS OF
SAME SIZE FOR 1200A FEED
(UPGRADE GROUND TO #310)
�(4) 21 "C W/ (4)#350 CU
(1) #1/0 GND CU XHHW
(4)3°C 4#350 CU-)
11/3/0 GND CU
-(4)3°C 4#350 CU
1#3/0 GND CU
600A EHM2
0
EMSB1
1200A, 277/480V, 30
EXISTING
W
CL
a
a.
UI
EHM 1
600A
MLO
480V
304W
EHM2
600A
MLO
480V
304W
EHS1
400A
M LO
480V
304W
EHS2
400A
MLO
480V
304W
4"C. w/ 41/3 CU
1#3 GND CU
(2)3"C. w/ 3#350 CU
1#1 GND CU
150K VA
T-ELS1
ELS1-1
600A
MCB
480V
304W
ELS 1-2
600A
MLO
480V
304W
(2)3"C.-,'
4#350 CU
1//1 GND CU
3OKVA
T -GP
GP
100A
MCB
208V
304W
800A STANDBY FEED
xmw;w0000mouom Comooaoommmcc000«r0000 om
(3 2)/2"C W/ (3)#300 CU,
1) #1/0 GND CU
3 2Y"C W/ (3)#300 CU,
1 #1/0 GND CU
2Y"C W/ (3)11300 CU,
#1/0 GND CU
0
800A UPS -A
(2)3"C.-
4/1350 CU #1/0 cu
1#1 GND CU
-(2 3"C.
4 350 CU
1#1 GND CU
#6cu -1)/1"C.
4#3 CU
1#8 GNU CU
EMSB2
1200A, 277/480V, 30
EXISTING
NEW
UPS -A
500KW
480V
304W
REVISIONS '"�
No changes shall be made to the scope
of work withal.* prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
800A STANDBY FEED
()#4 GN
(3CU250 CU,
[SEPARATE PERMIT
REQUIRED FOR:
ralil2chan
0 Electrical
E9iPlumbtr
fiMas Piping
City of Tukwila
BUILDING DIVISION
(3 2)/2"C W/ (3)#300 CU,
1) #1/0 GND CU
22"C W/ (3)#250 CU,
(i�#4 GND CU
*444..4 44 444 444. 404164.4.
401114.4.0.0110.0.1100.1 11,40
MBC -A
800A
MAINT.
BYPASS
480V
304W
PDU-A1
250A
132KW
208V
304W
PDU-A2
250A
132KW
209V
304W
-(3' 2Y"C W/ (3)#300 CU,
(1) #110 GND CU
PDU-A3
250A
132KW
208V
304W
NEW
(4) 3" C W/ (4)#350 CU
(1) #310 GND CU XHHW
THIS GEAR TO BE LOCATED
ON LEVEL 3 NEAR UPS -B
LEVEL 1
EXIST.
(2)2"C
4(3/0 CU
2 1/2°C 31/250 CU
1#4 GND CU
PDU 1
225A
W/INTERGAL
XFRMR
164 CKTS
EXIST.
MBP -1
Q(0
0
to
N
Q( 0
N 250A
J
1250A
EXIST.
c' 1)3°C
#1 GND /CU3)#350 ril
2 1/2°C 311250 CU
1#4 GND CU
(1 3°C W/ (3)#250 CU
13#1 GND CU
BATT.
UPS -1A
300A
Qb
O
0
EXIST.
BATT.
UPS -1B
300A
Qb
0
0
M o
EXIST.
6(1 3°C W/ (3)#350 CU
1)#1 GND CU
1 3°C W/ (3)#350 CU
1�#1 GND CU
PDU 2
500A
W/INTERGAL
XFRMR
164 CKTS
EXIST.
2 1/2°C 311250 AL
/1114 GND AL
MBP -2
0Q( 0
500A
-o o°
500A
T -o 0
500A
2 21i"C W/ (3)#250 AL
1#1 GND AL
EXIST.
(2 2%"C W/ (3)#250 AL
1)#1 CND AL
334"C 3#6 CU
11/10 GNU CU
CRAC #4
60A
480V
NEW
1Y"C 3#3 CU
1118 GND CU
CRAC #3
OOA
480V
EXISTING
1 112°C 3#2 CU
1#6 GND CU
CRAC #2
11OA
480V
EXISTING
34"C 31/6 CU
1#10 GND CU
3#10 CU
CRAC #1
60A
480V
NEW
✓\/l
/`V
FAN -2
5HP
8A
/07
FAN -1
5HP
8A
MECH-1
600A
EXISTING
(2 3"C 411350 CU
1 1 GND CU
BATT.
EXIST.
UPS -2A
500A
ab
0
0
U) o
EXIST.
BATT.
E:
(2)21°C
1#2 31/250
AL
UPS -2B
500A
ab
0
U) 0
0
(2)2/72 1#2#250 AL
GND AL
NEW
UPS -B
500KW
480V
304W
MBC -B
800A
MAINT.
BYPASS
480V
304W
PDU-B1
250A
132KW
208V
304W
CU
T', 1 T.
o
4
CCD(
(
D
0 0
071(
N
D
0 4
a:0(
11111111i
0 g/l
(ill(
a
U1(
EMSB3
Ce
N(
NEW
Q
0. Cf1(
(
(a/)(
C
fall(
1200A, 277/480V, 30
A x.� to i L� i� i .u. ti ria , i. , i
(2)2.1,,,1#2#250 AL
GND AL
PDU 3
500A
N/INTERGAL
XFRMR
164 CKTS
EXIST.
MBP -3
500A
0-0 0
< 0
0
0
U) o
500A
500A
0
PDU-B2
250A
132KW
208V
304W
PDU-B3
250A
132KW
208V
304W
:c.•
(2)?Y2 4250 AL
1#2 GND AL
r
EXIST.
BATT.
UPS -3A
500A
o,1
0
to O
EXIST.
BATT.
e(2)2Yz"C 3#250 AL
1#2 GND AL
UPS -3B
500A
ob
0
U) 0
1Y4' C.
43 CU
1 6 GND CU
(3)4°C 411600 CU
1#3/0 GNU CU
4°C 4#600 CU
1#3/0 GND CU
<1°
O
O
Q °
O
O
M O
OI O O o ClO O
Cl 0 0 O 0 0
U) o if) o 0 o U) o U) o to
Q °
O
O
1200A MAIN SWITCHBOARD 480V, 30
LEVEL P1
(4)3°C 4#350
1#3/0 GND CU
(3)4"C 411600 CU
1#3/0 GNU CU
EXISTING
SR
ATS
1200A
EXISTING
(2)3"C 3#350 AL
1#1/0 GND AL
MB -L1
100A
MCB
I20/208V
304W
34"C. -
3#8 CU
11110 GND CU
30KVA
Secondary
120/208V
MB -H1
100A
MLO
277/480V
304W
AUXILLARY
PNL
1200A
EXISTING
WITH
(2)KIRK KEY
INTERLOCK
VEL
LEVEL 2
(2)2Y 1#2 31/250 AL
GND AL
eNt
Ln
oo
0
0
C •
6�
o�
V
LuW
o
F4
41.4
N,
U
WOWRACK
International
Gateway Corporate
Park
Building B
12201 Tukwila International Blvd
Tukwila, WA 98168
FILE COPY
Permit No. X1-1 1-- a loz
Plan review cxwr c' al is subject to errors and omissions.
Approval of censer fiction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions Is owiedged:
By:
Date: II , -7
City of Tukwila
BOLDING DIVISION
LEVEL 1
BLDG. ' BLDG.
INTERIOR I EXTERIOR
2JJ"C
%-3#350 AL
1,2 GND AL
MECH-2
500A
CHILLER #2
100 TON
250A
EXISTING
PUMP #2
EXISTING
250A
11/4"C.-
41/3 CU
1#6 GND CU
#6cu
21,"C
3#350 AL
1#2 GND AL
- 250A
�
30A
- o °
30A
0 -
EXISTING
3/4°C 3#10 CU
410 GND CU
34"C 31/10 CU
111110 GND CU
PUMP #1
EXISTING
CHILLER #1
100 TON
250A
EXISTING
MAY
k. -
3
4
3,
LUIa
R
1 I
LEVEL P1
10/25/2017 UPS REPLACEMENT
LEVEL P2
MTS -1
1200A
480V
304W
EXIST.
v' 800A
750 KW
GEN
480/3
41/o OND CU
ROLL UP
GEN
TERM BOX
DIST. 1
DIST. 1
MSB
2500A MLO
277/480V, 30
EXISTING
CT
HP
225A
MLO
277/480V
304W
EXIST.
`-2Y"C 4111/0 CU
1#4 GND CU
EXIST.
3#6 CUJ
45KVA
XFRMR
LP
150A
MCB
120/208V
304W
EXIST.
#2 GND CU
#2 GND CU
2"C 4#1/0 CU
11116 GND CU
DIST. PNL
1200A
EXIST. /-I
iY4°C 3#3 CU
ELEV.
125A ST.
EXIST.
EXIST.
1Y"C 31/3 CU
ELEV.
/-1
125A ST.
(3)4°C 4#600 CU
BLDG.
INTERIOR
BLDG
Dot
REVIEWED FOR
(-MPLIANCE WITH
NEPA 70 m NEC
IOR NOV 07 2017
Wf
ty of Tukwila
BUILDING DIVISION
SPl717Lr1--
T
EXISTING
1 _I
(7)4°C 31/750 AL
1000KW
480V, 1600A
GENERATOR
(TRIP SET AT 1200A)
RECEIVED
CITY OF TUKWILA
OCT 3 0 X011
PERMIT CENTER
LEVEL P2
Riser Diagram
E1.1
JOB NUMBER
(.1'1.w (AK- #50394
IIx