HomeMy WebLinkAboutPermit EL17-0862 - WOWRACK - UPS REPLACEMENTWOWRACK 12201 TUKWILA INTL BLVD BLDG B EXPIRED 05/08/18 ELI 7-0862 )City of Tukwila Parcel No: Address: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 0923049120 Permit Number: EL17-0862 12201 TUKWILA INTL BLVD BLDG B Project Name: WOWRACK Issue Date: Permit Expires On: 11/9/2017 5/8/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BL, SEATTLE, WA, 98168 MATT BENDER 18133 NE 68TH ST, D-120 , REDMOND, WA, 98052 PRIDE ELECTRIC INC 18133 NE 68 ST, STE D120 , REDMOND, WA, 98052 PRIDEEI077DR !I, Phone: (425) 454-3665 Phone: (425) 454-3665 Expiration Date: 3/19/2019 DESCRIPTION OF WORK: (2) UPS REPLACEMENT AND ASSOCIATED GEAR PER PLAN -JOB #50394 Valuation of single family: $0.00 Valuation of mf/comm: $43,000.00 Type of Work: TENANT IMP Fees Collected: $1,134.73 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 20 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2015 ('` n I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. t /�/ Signature: � �/G Date: I 1 `� I 0 Print Name: rf /t/yAye '1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW�1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit. No. Project No. - 3 D l Date Application Accepted: _ l Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 12201 Tukwila International Blvd Tenant Name: WOWRACK PROPERTY OWNER Name: Matt Bender Address: 18133 NE 68th St, D-120 Name: Phone: (425) 454-3665 Fax: (425) 497-8700 Email: mbender@prideelectric.com Address: City: State: Zip: CONTACT PERSON -person receiving all project communication Name: Matt Bender Address: 18133 NE 68th St, D-120 City: Redmond State: WA Zip: 98052 Phone: (425) 454-3665 Fax: (425) 497-8700 Email: mbender@prideelectric.com King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ® .. No ELECTRICAL CONTRACTOR INFORMATION Company Name: Pride Electric, Inc. Address: 18133 NE 68th St, D-120 City: Redmond State: WA Zip: 98052 Phone: (425) 454-3665 Fax: (425) 497-8700 Contr Reg No.: PRIDEEI077DR Exp Date: 03/19/2019 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 43,000 Scope of Work (please provide detailed information): (2) UPS replacement and associated gear per plan - Job #50394 Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes m No Type of Use: COmmercial Type of work: ❑ New 0 Addition 0 Service Change ® Remodel ® Tenant Improvement 0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: El Puget Sound Energy 0 Seattle City Light W:\Pennit Center \Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised I-I-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES Service change or alteration $83.54 (no added/altered circuits) Service change with added/altered circuits $83.54 number of added circuits $12.00 ea Circuits added/altered without service change $55.69 (up to 5 circuits) Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea Meter/mast repair $69.62 Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride aad generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATIONNOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Matt Bender Mailing Address: 18133 NE 68th St, D-120, Redmond, WA 98052 W:\Permit Center\Applications-Handouts\Permit Applications \PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Date: 10/30/2017 Day Telephone: (425) 454-3665 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT PermitTRAK QUANTITY PAID $1,134.73 EL17-0862 Address: 12201 TUKWILA INTL BLVD BLDG B Apn: 0923049120 $1,134.73 ELECTRICAL $1,091.09 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $872.87 PLAN CHECK FEE R000.345.832.00.00 0.00 $218.22 TECHNOLOGY FEE $43.64 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12686 R000.322.900.04.00 0.00 $43.64 $1,134.73 Date Paid: Monday, October 30, 2017 Paid By: PRIDE ELECTRIC INC Pay Method: CHECK 7117 Printed: Monday, October 30, 2017 2:30 PM 1 of 1 SYSTEMS a31N331I1/11HJr! 10/7/2017 0:00 10/7/2017 2:38 10/7/2017 5:16 10/7/2017 7:54 10/7/2017 10:32 10/7/2017 13:10 10/7/2017 15:48 10/7/2017 18:26 10/7/2017 21:04 10/7/2017 23:42 10/8/2017 2:20 10/8/2017 4:58 10/8/2017 7:36 10/8/2017 10:14 10/8/2017 12:52 10/8/2017 15:30 10/8/2017 18:08 10/8/2017 20:46 10/8/2017 23:24 10/9/2017 2:02 10/9/2017 4:40 n 1 10/9/2017 7:18 10/9/2017 9:56 m 10/9/2017 12:34 f '< 73 Pi 10/9/2017 15:12 Z 0 rn 10/9/2017 17:50 m 0 10/9/2017 20:28 ems" -� rn 10/9/2017 23:06 C < m 10/10/2017 1:44 rte^ ? rfl W 10/10/2017 4:22 V10/10/2017 7:00 �= 10/10/2017 9:38 10/10/2017 12:16 10/10/2017 14:54 10/10/2017 17:32 10/10/2017 20:10 10/10/2017 22:48 10/11/2017 1:26 10/11/2017 4:04 10/11/2017 6:42 10/11/2017 9:20 10/11/2017 11:58 10/11/2017 14:36 10/11/2017 17:14 10/11/2017 19:52 10/11/2017 22:30 C\ c 10/12/2017 3:46 10/12/2017 3:46 m v 10/12/2017 6:32 W m 10/12/2017 9:10 C 33 CI° 10/12/2017 11:48 rCD m 10/12/2017 14:26 n _:-t .�.. M10/12/2017 17:0410/12/2017 19:42 Z 010/12/2017 22:2010/13/2017 0:58 c tri o [ , 0 0 0 0 0 CI 10/13/2017 3:36 10/13/2017 6:14 ` . o� Z m',N 10/13/2017 8:52Ci ice 10/13/2017 11:30 m 10/13/2017 14:08 a'y x 1111 10/13/2017 16:46 10/13/2017 19:24 10/13/2017 22:02 L 1 C N W N C 8 o a C l0 Dco CD aaewnN eor M1 paaa1aN 0 0 0 18133 NE 68th Street Suite D-120 Redmond, WA 98052 425-454-3665 WWW.PRIDEELECTRIC.COM 10/7/2017 0:00 10/7/2017 2:38 10/7/2017 5:16 10/7/2017 7:54 10/7/2017 10:32 10/7/2017 13:10 10/7/2017 15:48 10/7/2017 18:26 10/7/2017 21:04 10/7/2017 23:42 10/8/2017 2:20 10/8/2017 4:58 10/8/2017 7:36 c 10/8/2017 10:14 TO 10/8/2017 12:52 10/8/2017 15:30 3 10/8/2017 18:08 10/8/2017 20:46 10/8/2017 23:24 10/9/2017 2:02 10/9/2017 4:40 10/9/2017 7:18 10/9/2017 9:56 10/9/2017 12:34 10/9/2017 15:12 10/9/2017 17:50 10/9/2017 20:28 10/9/2017 23:06 10/10/2017 1:44 10/10/2017 4:22 10/10/2017 7:00 10/10/2017 9:38 10/10/2017 12:16 10/10/2017 14:54 10/10/2017 17:32 10/10/2017 20:10 10/10/2017 22:48 10/11/2017 1:26 10/11/2017 4:04 10/11/2017 6:42 10/11/2017 9:20 10/11/2017 11:58 10/11/2017 14:36 10/11/2017 17:14 10/11/2017 19:52 10/11/2017 22:30 10/12/2017 1:08 10/12/2017 3:46 10/12/2017 6:32 10/12/2017 9:10 10/12/2017 11:48 10/12/2017 14:26 10/12/2017 17:04 10/12/2017 19:42 10/12/2017 22:20 10/13/2017 0:58 10/13/2017 3:36 10/13/2017 6:14 10/13/2017 8:52 10/13/2017 11:30 10/13/2017 14:08 10/13/2017 16:46 10/13/2017 19:24 10/13/2017 22:02 (sdwy) y aseyd luaaanD (sdwy) 9 maid ;ua.unj- (sdwy) p aseyd;uaJJnD- 1138Wf1N 9O( wauro paaaaaW 0 0 0 0 O m O O 0 O 0 O 0 00 O O 7C r, co fl)QJ 7 C d f"1 7 - Cul O cu cu Da co K r'r co 5 O c FII co M 18133 NE 68th Street Suite D-120 Redmond, WA 98052 425-454-3665 WWW.PRIDEELECTRIC.COM PERFORMANCE Bill of Materials ITEM 1) Eaton Series 9395 — 550kVA with 99% high eff. ESS firmware (2) 550kVA/500kW Uninterruptible Power System System Rating: 550kVA/500kW System Input Voltage: 480VAC, three phase, 3 wire plus G, 60 Hertz System Output Voltage: 480VAC, three phase, 3 wire plus G, 60 Hertz Recommended input breaker: 800A 100% rated (8) Eaton E28 Sealed, valve regulated lead acid (VRLA) Battery Cabinets Runtime: 5 minutes (2) Wall -Mount MBP solution (2) Breaker 1000A 80% rated 65kAIC, C/w SKRU Key interlock solution included. UPS Module shall consist of the following: — Double Conversion Online (IGBT), 95% efficiency, 99% with ESS firmware — Lot Redundant Cooling Fans — Lot Redundant Power Supplies — Eaton's ABM technology 1 — Operations Manual 1 — Common battery 1 — Xpert SNMP/Modbus TCP/IP Card 1 — Indy Relay card 1 — Seismic brackets for the UPS and battery cabinets UPS Dimensions: Battery Dimensions: MBP Dimensions: Performance Power Concepts, Inc. 11636 SE 5th Street, Suite 200 Bellevue, WA 98005 Tel: (425) 638-0340/Fax: (425) 638-0341 73.8"W x 32.7"D x 73.6"H, (3,184 lbs.) each 44.3"W x 31.6"D x 74.0"H, (3,250 lbs.) (4 required per UPS) 36"W x 11.3"D x 73.5"H, (700 lbs.) each REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC NOV 07 2011 City of Tukwila BUILDING DIVISION__ A U T 1-1 O R 1 Z E Representative 4/2/2018 City of Tukwila Department of Community Development MATT BENDER 18133 NE 68TH ST, D-120 REDMOND, WA 98052 RE: Permit No. EL17-0862 WOWRACK 12201 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/8/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/8/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, �V1 chelle Ripley Permit Technician File No: EL17-0862 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0862 DATE: 1 0/30/1 7 PROJECT NAME: WOWRACK SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: `, c U4I7 Building Division i" Public Works Fire Prevention Structural Ei Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWEROS INITIALS: DATE: 11/02/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/30/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERcS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PRIDE ELECTRIC INC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of )Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L&I Workplace Rights Trades & Licensing PRIDE ELECTRIC INC Owner or tradesperson Principals GOAD, CHRISTOPHER J, PRESIDENT GOAD, ROBERT L, VICE PRESIDENT GOAD, KIRK A, SECRETARY GOAD, CHRISTOPHER J, AGENT SEELEY, ROBERT M, PRESIDENT (End: 03/15/2005) SEELEY, KAROLYN J, SECRETARY (End: 03/15/2005) SEELEY, ROBERT M, AGENT (End: 03/15/2005) Doing business as PRIDE ELECTRIC INC WA UBI No. 601 451 700 18133 NE 68TH ST D120 REDMOND, WA 98052 425-454-3665 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. PRIDEE1077DR Effective — expiration 03/19/1993— 03/19/2019 Designated administrator GOAD, CHRISTOPHER J License type Master Electrician Bond ................ TRAVELERS CAS & SURETY CO Bond account no. 103366931 Active. Meets current requirements. License no. GOAD*CJ955DG $4,000.00 Received by L&I Effective date 04/01/2005 03/17/2005 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 11/9/2017 PRIDE ELECTRIC INC License Violations 0 o Infraction no. EMOMJ00691 Satisfied RCW/WAC Issue date 11/24/2015 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. ELY0D00260 Issue date 10/09/2013 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. 19.28.101 RCW Violation amount $1,000.00 Satisfied ........._.............. RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 842,543-00 ................................ Doing business as PRIDE ELECTRIC Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T3 / KAYLENE MONIER (360)902-6627 - Email: BRKB235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid ............._.............................................................................. No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/09/2012 Inspection no. 315812677 Location 2701 142nd Ave E Sumner, WA 98390 Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601451700&LIC=PRIDEEI077DR&SAW= 11/9/2017 LEVEL 3 1Y4"C W/ (3)#3 CU, 1118 CU GND [2)/2"C W/ 4#4/0 CU 1#4 GND CU 75KVA T-LR1 LR1 225A MCB 208V 304W HL1 225A MLO 480V 304W J 4 ° If) N N 0 #4cu LEVEL 2 - 2Y"C, w/4#4/0 CU 1114 GND CU CL J to N SBS 800A, 277/480V, 30 EXISTING (2)SETS OF (4)250 MC AL CABLE w/ GND (1) /0 GND 3CU300 CU REPLACE EXISITNG 800A BREAKER WITH 1200A BREAKER D3 400A MLO 277/480V 304W NEW CC U) Li 0 co 0 1000A SPARE I Iwtw1 1 U)( o U))(0Vim)() ((1)(0 1200A ATS a ° U) m U) 0 0 0 ° W Ct a a U) L)-- 0 00 2 O N (V MDP 2000AF/1200AT 277/480V, 30 EXISTING ATS -1 1200A 480V 304W PULL BOX ADD (1) PARALLEL FEEDER TO EXISTING (3) FEEDERS OF SAME SIZE FOR 1200A FEED (UPGRADE GROUND TO #310) �(4) 21 "C W/ (4)#350 CU (1) #1/0 GND CU XHHW (4)3°C 4#350 CU-) 11/3/0 GND CU -(4)3°C 4#350 CU 1#3/0 GND CU 600A EHM2 0 EMSB1 1200A, 277/480V, 30 EXISTING W CL a a. UI EHM 1 600A MLO 480V 304W EHM2 600A MLO 480V 304W EHS1 400A M LO 480V 304W EHS2 400A MLO 480V 304W 4"C. w/ 41/3 CU 1#3 GND CU (2)3"C. w/ 3#350 CU 1#1 GND CU 150K VA T-ELS1 ELS1-1 600A MCB 480V 304W ELS 1-2 600A MLO 480V 304W (2)3"C.-,' 4#350 CU 1//1 GND CU 3OKVA T -GP GP 100A MCB 208V 304W 800A STANDBY FEED xmw;w0000mouom Comooaoommmcc000«r0000 om (3 2)/2"C W/ (3)#300 CU, 1) #1/0 GND CU 3 2Y"C W/ (3)#300 CU, 1 #1/0 GND CU 2Y"C W/ (3)11300 CU, #1/0 GND CU 0 800A UPS -A (2)3"C.- 4/1350 CU #1/0 cu 1#1 GND CU -(2 3"C. 4 350 CU 1#1 GND CU #6cu -1)/1"C. 4#3 CU 1#8 GNU CU EMSB2 1200A, 277/480V, 30 EXISTING NEW UPS -A 500KW 480V 304W REVISIONS '"� No changes shall be made to the scope of work withal.* prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 800A STANDBY FEED ()#4 GN (3CU250 CU, [SEPARATE PERMIT REQUIRED FOR: ralil2chan 0 Electrical E9iPlumbtr fiMas Piping City of Tukwila BUILDING DIVISION (3 2)/2"C W/ (3)#300 CU, 1) #1/0 GND CU 22"C W/ (3)#250 CU, (i�#4 GND CU *444..4 44 444 444. 404164.4. 401114.4.0.0110.0.1100.1 11,40 MBC -A 800A MAINT. BYPASS 480V 304W PDU-A1 250A 132KW 208V 304W PDU-A2 250A 132KW 209V 304W -(3' 2Y"C W/ (3)#300 CU, (1) #110 GND CU PDU-A3 250A 132KW 208V 304W NEW (4) 3" C W/ (4)#350 CU (1) #310 GND CU XHHW THIS GEAR TO BE LOCATED ON LEVEL 3 NEAR UPS -B LEVEL 1 EXIST. (2)2"C 4(3/0 CU 2 1/2°C 31/250 CU 1#4 GND CU PDU 1 225A W/INTERGAL XFRMR 164 CKTS EXIST. MBP -1 Q(0 0 to N Q( 0 N 250A J 1250A EXIST. c' 1)3°C #1 GND /CU3)#350 ril 2 1/2°C 311250 CU 1#4 GND CU (1 3°C W/ (3)#250 CU 13#1 GND CU BATT. UPS -1A 300A Qb O 0 EXIST. BATT. UPS -1B 300A Qb 0 0 M o EXIST. 6(1 3°C W/ (3)#350 CU 1)#1 GND CU 1 3°C W/ (3)#350 CU 1�#1 GND CU PDU 2 500A W/INTERGAL XFRMR 164 CKTS EXIST. 2 1/2°C 311250 AL /1114 GND AL MBP -2 0Q( 0 500A -o o° 500A T -o 0 500A 2 21i"C W/ (3)#250 AL 1#1 GND AL EXIST. (2 2%"C W/ (3)#250 AL 1)#1 CND AL 334"C 3#6 CU 11/10 GNU CU CRAC #4 60A 480V NEW 1Y"C 3#3 CU 1118 GND CU CRAC #3 OOA 480V EXISTING 1 112°C 3#2 CU 1#6 GND CU CRAC #2 11OA 480V EXISTING 34"C 31/6 CU 1#10 GND CU 3#10 CU CRAC #1 60A 480V NEW ✓\/l /`V FAN -2 5HP 8A /07 FAN -1 5HP 8A MECH-1 600A EXISTING (2 3"C 411350 CU 1 1 GND CU BATT. EXIST. UPS -2A 500A ab 0 0 U) o EXIST. BATT. E: (2)21°C 1#2 31/250 AL UPS -2B 500A ab 0 U) 0 0 (2)2/72 1#2#250 AL GND AL NEW UPS -B 500KW 480V 304W MBC -B 800A MAINT. BYPASS 480V 304W PDU-B1 250A 132KW 208V 304W CU T', 1 T. o 4 CCD( ( D 0 0 071( N D 0 4 a:0( 11111111i 0 g/l (ill( a U1( EMSB3 Ce N( NEW Q 0. Cf1( ( (a/)( C fall( 1200A, 277/480V, 30 A x.� to i L� i� i .u. ti ria , i. , i (2)2.1,,,1#2#250 AL GND AL PDU 3 500A N/INTERGAL XFRMR 164 CKTS EXIST. MBP -3 500A 0-0 0 < 0 0 0 U) o 500A 500A 0 PDU-B2 250A 132KW 208V 304W PDU-B3 250A 132KW 208V 304W :c.• (2)?Y2 4250 AL 1#2 GND AL r EXIST. BATT. UPS -3A 500A o,1 0 to O EXIST. BATT. e(2)2Yz"C 3#250 AL 1#2 GND AL UPS -3B 500A ob 0 U) 0 1Y4' C. 43 CU 1 6 GND CU (3)4°C 411600 CU 1#3/0 GNU CU 4°C 4#600 CU 1#3/0 GND CU <1° O O Q ° O O M O OI O O o ClO O Cl 0 0 O 0 0 U) o if) o 0 o U) o U) o to Q ° O O 1200A MAIN SWITCHBOARD 480V, 30 LEVEL P1 (4)3°C 4#350 1#3/0 GND CU (3)4"C 411600 CU 1#3/0 GNU CU EXISTING SR ATS 1200A EXISTING (2)3"C 3#350 AL 1#1/0 GND AL MB -L1 100A MCB I20/208V 304W 34"C. - 3#8 CU 11110 GND CU 30KVA Secondary 120/208V MB -H1 100A MLO 277/480V 304W AUXILLARY PNL 1200A EXISTING WITH (2)KIRK KEY INTERLOCK VEL LEVEL 2 (2)2Y 1#2 31/250 AL GND AL eNt Ln oo 0 0 C • 6� o� V LuW o F4 41.4 N, U WOWRACK International Gateway Corporate Park Building B 12201 Tukwila International Blvd Tukwila, WA 98168 FILE COPY Permit No. X1-1 1-- a loz Plan review cxwr c' al is subject to errors and omissions. Approval of censer fiction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Is owiedged: By: Date: II , -7 City of Tukwila BOLDING DIVISION LEVEL 1 BLDG. ' BLDG. INTERIOR I EXTERIOR 2JJ"C %-3#350 AL 1,2 GND AL MECH-2 500A CHILLER #2 100 TON 250A EXISTING PUMP #2 EXISTING 250A 11/4"C.- 41/3 CU 1#6 GND CU #6cu 21,"C 3#350 AL 1#2 GND AL - 250A � 30A - o ° 30A 0 - EXISTING 3/4°C 3#10 CU 410 GND CU 34"C 31/10 CU 111110 GND CU PUMP #1 EXISTING CHILLER #1 100 TON 250A EXISTING MAY k. - 3 4 3, LUIa R 1 I LEVEL P1 10/25/2017 UPS REPLACEMENT LEVEL P2 MTS -1 1200A 480V 304W EXIST. v' 800A 750 KW GEN 480/3 41/o OND CU ROLL UP GEN TERM BOX DIST. 1 DIST. 1 MSB 2500A MLO 277/480V, 30 EXISTING CT HP 225A MLO 277/480V 304W EXIST. `-2Y"C 4111/0 CU 1#4 GND CU EXIST. 3#6 CUJ 45KVA XFRMR LP 150A MCB 120/208V 304W EXIST. #2 GND CU #2 GND CU 2"C 4#1/0 CU 11116 GND CU DIST. PNL 1200A EXIST. /-I iY4°C 3#3 CU ELEV. 125A ST. EXIST. EXIST. 1Y"C 31/3 CU ELEV. /-1 125A ST. (3)4°C 4#600 CU BLDG. INTERIOR BLDG Dot REVIEWED FOR (-MPLIANCE WITH NEPA 70 m NEC IOR NOV 07 2017 Wf ty of Tukwila BUILDING DIVISION SPl717Lr1-- T EXISTING 1 _I (7)4°C 31/750 AL 1000KW 480V, 1600A GENERATOR (TRIP SET AT 1200A) RECEIVED CITY OF TUKWILA OCT 3 0 X011 PERMIT CENTER LEVEL P2 Riser Diagram E1.1 JOB NUMBER (.1'1.w (AK- #50394 IIx