HomeMy WebLinkAboutPermit EL17-0870 - BOEING #9-101 - THERMAL PLASTIC MACHINEBOEING #9-101 9725 E MARGINAL WAY S BLDG 9-101 ELI 7-0870 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 0003400018 Permit Number: EL17-0870 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: 11/9/2017 Permit Expires On: 5/8/2018 Project Name: BOEING #9-101 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 MICHELE AMATO 15135 NE 92 ST, REDMOND, WA, 98052 SEQUOYAH ELECTRIC LLC 15135 NE 92ND ST, REDMOND, WA, 98052-3519 SEQUOEL977S9 Phone: (425) 766-3094 Phone: (425) 814-6000 Expiration Date: 1/30/2019 DESCRIPTION OF WORK: INSTALLATION OF NEW THERMAL PLASTIC MACHINE. Valuation of single family: $0.00 Valuation of mf/comm: $163,090.00 Type of Work: TENANT IMP Fees Collected: $3,248.66 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: 1-cr-17 4 ti I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regul ti/ntZonstruction or the performance of work. I am authorized to sign and obtain this development per - d gree to he conditions attached to this permit. Signature: Print Name: M IC.J6U9 i, 1 Date: 1 U'9 'l7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB eahl Job #31879 CITY OF TUKWL..A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. gov ,N Electrical Permit No. 1, II 0/S110 Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 9725 East Marginal Way South King Co Assessor's Tax No.: Suite Number: Floor: Tenant Name: Boeing Company PROPERTY OWNER Name: Michele Amato Name: Boeing Company City: State: Zip: Address: PO BOX 3707 MS 1W-09 Email: michele.amato@sequoyah.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Michele Amato Address: . City: State: Zip: Phone: (425) 766-3094 Fax: Email: michele.amato@sequoyah.com New Tenant: ❑ Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Sequoyah Address: 15135 NE 92nd St City: Redmond State: WA Zip: 98052 Phone: (425) 814-6000 Fax: (425) 814-6003 Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 163,090 Scope of Work (please provide detailed information): Installation of new thermal plastic machine Will service be altered? m Yes ❑ No Adding more than 50 amps? 66 Yes ❑ No Type of Use: Type of work: ® New 0 Addition 0 Service Change 0 Remodel ❑ Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: ❑ Puget Sound Energy 0 Seattle City Light W:\Permit Center\Applications-Handouts\Permit Applications \PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE D New single family dwellings $155.91 (including an attached garage) O Garages, pools, spas and outbuildings $83.54 ea O Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) • Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES 0 Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF 'HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRAC Signature: Print Name: pie./ T. L L. -'L al /s/36- /(/E `dn/D �I Mailing Address: W:\Permit Center\Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Day Telephone: 4�l Xn20'4 City Date: /1%v</ /7 sole C'f - %W1 IA 90d.�-a State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT QUANTITY PermitTRAK PAID $3,714.04 EL17-0870 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $2,623.92 ELECTRICAL $2,498.97 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 I 0.00 $2,498.97 TECHNOLOGY FEE $124.95 TECHNOLOGY FEE R000.322.900.04.00 0.00 $124.95 EL17-0897 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $1,090.12 ELECTRICAL $1,038.21 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,038.21 TECHNOLOGY FEE $51.91 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R12764 $51.91 $3,714.04 Date Paid: Thursday, November 09, 2017 Paid By: SEQUOYAH LLC Pay Method: CHECK 554086 Printed: Thursday, November 09, 2017 3:16 PM 1 of 1 CIIIWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY PAID PermitTRAK $624.74 EL17-0870 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $624.74 ELECTRICAL $624.74 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12707 R000.345.832.00.00 0.00 $624.74 $624.74 Date Paid: Wednesday, November 01, 2017 Paid By: SEQUOYAH Pay Method: CHECK 554042 Printed: Wednesday, November 01, 2017 2:43 PM 1 of 1 CRWSYSTEMS 2 - INSPECTION NO. INSPECTION RECORD Retain a copy with permit PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ,<7 ?.1 Type of Inspection: !V 'V Address: 7 / Date Called: Special Instructions: I Date Wanted: 0 6. 7-n Requester: • Phone No:q�, �' 7 2 /Z Approved per applicable codes. Corrections required prior to approval. OM M ENTS: Inspect Date: 0,/ ,!%g REINSPECIiION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2 -INSPECTION RECORD Retain a copy with permit 1%c ' 7O INSPECTION NO. P M� IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Address: 77 644 14o/ 6- sti- Special Ins ructions: (206) 431-364 fIType of Inspection: 4.i# ,, Date Called: Date Wanted: Requester: Approved per applicable codes. Phone No: //Pp 7 ` ;07i -f LJ Corrections required prior to approval. COMMENTS: �ANL:LGi,AA-D Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ei � J 16 PER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431- Project: /7 ,_. 1 Type of Inspection:;f�� I Address: et .q, /2 f•' ~ • t , �'` Date Called: _ Special Instructions: Date Wanted: a.m. Requester: . Phone No: A �\.� ) o3 .�s Approved per applicable codes. Corrections required prior to approval. COMMENTS: �t ks\ 4 Inspector: ` Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SYM GROUNDING —r___ GROUND CABLE CONNECTION GROUND ROD CONNECTION GROUND CABLE PIGTAIL GROUND CABLE (UNDERGROUND) 6 —G- - G — INSULATED GROUND BUS BAR POWER - GENERAL [in PANELBOARD, 208Y/120V, 3 PHASE (O INDICATES SHUNT -TRIP) ® PANELBOARD, 480Y/277V, 3 PHASE PANELBOARD, 400 HZ, 200Y/115V I+ -I PANELBOARD, 28 VDC I I DC PANEL POWER SUPPLY, SIZE AS NOTED x EQUIPMENT IDENTIFICATION "X" DENOTES EQUIPMENT TYPE "Y" DENOTES EQUIPMENT NUMBER ® CIRCUIT BREAKER ENCLOSURE EB CKT. BKR. ENCLOSURE WITH SHUNT -TRIP DISCONNECT 30/20 SWTCHRATING/FUSE ( OR UNFUSED) RATING a MOTOR STARTER (COMBINATION) M MANUAL MOTOR STARTER Q TRANSFORMER (SIZE AS SHOWN, IN KVA) O JUNCTION BOX ® ON-OFF SELECTOR SWITCH ▪ SINGLE MOMENTARY PUSH BUTTON STATION 11 PUSHBUTTON STOP -START STATION 460 VOLT MOTOR (SIZE AS NOTED) 208 VOLT OR 240 V MOTOR (SIZE AS NOTED) 115 VOLT MOTOR (SIZE AS NOTED) © POWER FACTOR CORRECTION CAPACITOR ® TELEPHONE/POWER POLE TC TIME CLOCK © CONTACTOR RACEWAYS CONDUIT NOT BURIED (INCLUDING ABOVE SUSPENDED CEILING & UNDER RAISED FLOOR) BURIED CONDUIT WIRING (UNDERGROUND & IN FLOOR SLAB) FLEXIBLE METAL CONDUIT CONDUIT HASH MARK DESIGNATIONS PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUND CONDUCTOR ',.._ISOLATED GREEN GROUND CONDUCTOR CIRCUIT SOURCE >� PANEL/CIRCUIT BREAKER N0.(S) -1/1,3,5 CONDUIT TURNS DOWN —0 CONDUIT TURNS UP CONDUIT ONLY G.O. ISSUE FOR CONSTRUCTION 06.28.17 REVISION Br APPROVED YUAN JTML7ULJ POWER RECEPTACLES X15 20 IG X15 IG X20 EidG 20 IG 30 KD50 X30 0830 X60 X100 X200 DUPLEX, 2 POLE, 3 WIRE, PARALLEL BLADE, NEMA GROUNDING RECEPTACLE, 15 AMP, 120 V, HUBBELL 5262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2 POLE, 3 WIRE, STRAIGHT BLADE, NEMA GROUNDING RECEPTACLE, 20 AMP, 120 V, HUBBELL 5362 OR EQUAL PER BOEING STANDARDS DUPLEX, 2 POLE, 3 WIRE, PARALLEL BLADE, ISOLATED GROUND RECEPTACLE, 15 AMP, 120 V, HUBBELL 105262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2 POLE, 3 WIRE, PARALLEL BLADE, ISOLATED GROUND RECEPTACLE, 20 AMP, 120 V, HUBBELL 105362 OR EQUAL PER BOEING STANDARDS SINGLE, 2 POLE, 3 WIRE, TWISTLOCK, ISOLATED GROUND RECEPTACLE, 208 V, SINGLE PHASE, 20 AMP, HUBBELL IG 2320A SINGLE, 2 POLE, 3 WIRE, TWISTLOCK, ISOLATED GROUND, 30 AMP, 120 V RECEPTACLE, HUBBELL IG 2610A OR EQUAL PER BOEING STANDARDS SINGLE, 3 POLE, 3 WIRE, NON -GROUNDING, 50 AMP, 28 VDC RECEPTACLE, HUBBELL 7962 OR EQUAL PER BOEING STANDARDS SINGLE, 4 POLE, 4 WIRE, GROUND THRU SHELL, 30 AMP, 208Y/120 V, 3 PHASE, 400 HZ RECEPTACLE, RUSSELL-STOLL TYPE FC 3114W 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 30 AMP, CROUSE -HINDS ARE 3423 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 60 AMP, CROUSE -HINDS ARE 6425 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 100 AMP, CROUSE -HINDS AREA 10426 480 VAC, 4 POLE, 3 WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 200 AMP, CROUSE -HINDS AREA 20427 OUTLET MOUNTED IN BOX ATTACHED TO UNDERSIDE OF RAISED FLOOR TYPICAL FOR ALL OUTLET TYPES POWER OR TELEPHONE OUTLET MOUNTED IN DOUBLE BOX ATTACHED TO UNDER- SIDE OF RAISED FLOOR. TYPICAL OF ALL OUTLET TYPES OUTLET MOUNTED IN BOX ON SLAB P • I S 20 CEILING MOUNTED DUPLEX, 2 POLE, 3 WIRE, STRAIGHT BLADE, NEMA GROUNDING RECEPTACLE, 20 AMP, 120 V, HUBBELL 5362 OR EQUAL PER BOEING STANDARDS COMMUNICATIONS M TELEPHONE OUTLET DUPLEX TELEPHONE OUTLET FLUSH MOUNTED SIGNAL BELL DATA OUTLET VOLUME CONTROL SPEAKER, CEILING MOUNTED LOWBAY SPEAKER, HORN TYPE MID HEIGHT SPEAKER HORN TYPE LIGHTING I0I HIGH INTENSITY DISCHARGE (HID) FIXTURE FLOODLIGHT - WALL MTD. / POLE MTD. LIGHTING FIXTURE - 2' x 4' LAYIN FLUORESCENT WITH 3 TUBES LIGHTING FIXTURE - 2' x 4' LAPIN FLUORESCENT WITH 2 TUBES LIGHTING FIXTURE - 2' x 2' LAYIN FLUORESCENT WITH 2 TUBES LIGHT FIXTURE - 1' x 4' SURFACE OR PENDANT FLUORESCENT WITH 2 TUBES 2 -LAMP EMERGENCY LIGHTING UNIT WITH BATTERY BACKUP ▪ LIGHT FIXTURE TAP 1/2" FLEXIBLE METAL CONDUIT - 4 #12: TWO PHASE CONDUCTORS, ONE NEUTRAL, ONE GROUND SWI#12 FOR SINGLE OR COMMON BALLAST TCHI LIGHTING FIXTURE - 1' x 8' SURFACE OR PENDANT FLUORESCENT WITH 2 TUBES Fe1 EXIT SIGN, WALL MOUNTED 01 EXIT SIGN, CEIUNG MOUNTED 1-01 EXIT SIGN, WALL MOUNTED WITH BATTERY BACKUP e1 EXIT SIGN, CEILING MOUNTED WITH BATTERY BACKUP FIXTURE IDENTIFICATION "X" DENOTES FIXTURE TYPE "Y" DENOTES FIXTURE SUB -TYPE LIGHT SWITCH SEPARATE PERMIT REQUIRED FOR aKechartical 0 Electrical Plum aMas Pim City of Tukwila V_^!"1G DIVISION elt FIRE DETECTION —FA— a o e<e>O<>g FIRE ALARM SYSTEM RACEWAY FIRE ALARM HORN SMOKE DETECTOR - IONIZATION TYPE SMOKE DEFECTOR - PHOTOELECTRIC TYPE SMOKE DETECTOR BELOW RAISED FLOOR THERMAL DETECTOR FIRE ALARM PULL STATION EMERGENCY POWER OFF (E.P.O.) PUSHBUTTON CLUSTER HF'NS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal LI DLR Grdup and may include additional plan review fees, H •.. �..a.•L_,. SINGLE LINE o La) crrn I— / v YLT 3P -60A E19-1 400 A M. BKR. 3 PH, 4 E19-3 225 A M. BKR. 3 PH, 4W G19-2 100 A M. BKR. 400 HZ G19-1 100 A M. BKR. 28 VDC TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC SHIELD) SURGE ARRESTER CIRCUIT BREAKER W/ ELECTRICAL OPERATOR LT = LONG T.D. TRIP UNIT ST = SHORT T.D. TRIP UNIT I = INSTANT. TRIP UNIT GF = GND. FAULT TRIP UNIT POTENTIAL TRANSFORMER QUANTITY & RATIO AS SHOWN CURRENT TRANSFORMER QUANTITY Sc RATIO AS SHOWN AMMETER w/SWITCH VOLTMETER w/SWITCH WATTHOUR METER UI/ FU'M JTMUULJ SINGLE LINE ELECTRICAL POWER FILTER FUSED SWITCH DISCONNECT SWITCH GENERATOR TRANSFER SWITCH I—L I DISCONNECT SWITCH INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL FILE COPY BD i 1-174 0 070 —14 ,snit Na 3 WI�B��yE 480V OR 480 pproval is subject to Mill and construction documents drier not viOTD of any :,4,��r* e,: *. is tocknowledtet SCHEMATIC - DISCONNECT SWITCH - ED- FUSE CIRCUIT BREAKER TRANSFORMER - GROUND CONNECTION PUSHBUTTON —o - o— MOMENTARY CONTACT NORMALLY OPEN OFFON 1-0- 2 PILOT LIGHT * INDICATES COLOR a 0!'I 81 ! PANELBOARD (RATINGS NOTED) OR 2 Date. 400 HZ AC PANELBOARD (RATINGS AS NOTED) 28 VDC PANELBOARD (RATINGS AS NOTED) City of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA70-NEC NOV 07 2017 J COMBINATION STARTER CONTROLLER OR MCC CUBICLE NUMBER STARTER SIZE POWER FACTOR CORRECTION CAPACITOR -- MOTOR HORSEPOWER 0— City of •Tukwila BUILDING DIVISION • I -0 - RECEIVED CITY OF TUKWILA :12071% PERMIT CENTER —0- -o-T-0— PUSHBUTTON --oi PUSHBUTTON MOMENTARY CONTACT NORMALLY CLOSED SELECTOR SWITCH MAINTAINED CONTACT TWO POSITION SELECTOR SWITCH MAINTAINED CONTACT THREE POSITION SOLENOID VALVE PRESSURE SWITCH - N.C. OPENS ON RISING PRESSURE PRESSURE SWITCH - N.O. CLOSES ON RISING PRESSURE OPENS ON RISING LEVEL FLOAT OR LEVEL SWITCH - N.C. CLOSES ON RISING LEVEL FLOAT OR LEVEL SWITCH - N.O. FLOW SWITCH - N.C. OPENS ON INCREASE IN FLOW FLOW SWITCH - N.O. CLOSES ON INCREASE IN FLOW TEMPERATURE SWITCH - N.C. OPENS ON RISING TEMP TEMPERATURE SWITCH - N.O. CLOSES ON RISING TEMP LIMIT SWITCH - N.C. LIMIT SWITCH - N.O. RELAYS & COILS *=TYPE M=MOTOR STARTER CR=CONTROL RELAY C=CONTACTOR TR=TIME DELAY OR TIMING RELAY N.O. CONTACT N.C. CONTACT: N.O. - ON DELAY CONTACT N.C. - ON DELAY CONTACT N.O. - OFF DELAY CONTACT N.C. - OFF DELAY CONTACT GENERAL NOTES 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. USE #14 AWG FOR LOW VOLTAGE CONTROL WIRING. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION )j1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) B 0 (CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE X12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL -WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. ABBREVIATIONS AF AFF AHC AHU AL AT ATS AWG CB CMCS CO CRU DED DP EF EMCS EMT EPO ES EWC FACP FAR FDP FVNR FVR GF1 GND HP IMC kcMIL LV M.BKR. MCC MCM MLO NACB NEC N/A NC NO PA PH PNL PVC RF RVNR SRP SWBD SWGR SF ST TBD TD THHN THWN T/S UH VFD WP XFMR FRAME RATING IN AMPS ABOVE FINISHED FLOOR ABOVE HUNG CEILING AIR HANDLING UNIT ALUMINUM TRIP RATING IN AMPS AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE CIRCUIT BREAKER CENTRAL MANAGEMENT CONTROL SYSTEM CONDUIT ONLY COMPUTER ROOM UNIT DEDICATED DISTRIBUTION PANELBOARD EXHAUST FAN ENERGY MANAGEMENT CONTROL SYSTEM ELECTRICAL METALLIC TUBING EMERGENCY POWER OFF EPO SWITCH ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL FIRE ALARM RELAY FIRE DETECTION PANEL FULL VOLTAGE, NON -REVERSING FULL VOLTAGE, REVERSING GROUND FAULT INTERRUPTER GROUND HORSEPOWER INTERMEDIATE METAL CONDUIT THOUSAND CIRCULAR MILS LOW VOLTAGE MAIN BREAKER MOTOR CONTROL CENTER THOUSAND CIRCULAR MILS MAIN LUGS ONLY NON -AUTOMATIC CIRCUIT BREAKER NATIONAL ELECTRICAL CODE NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN PAGING SYSTEM PHASE PANEL POLY -VINYL CHLORIDE (CONDUIT) RETURN FAN REDUCED VOLTAGE, NON -REVERSING SMOKE REMOVAL PANEL SWITCHBOARD SWITCHGEAR SUPPLY FAN SHUNT TRIP (CIRCUIT BREAKER) TO BE DETERMINED TIME DELAY WIRE INSULATION TYPE WIRE INSULATION TYPE TWISTED & SHIELDED UNIT HEATER VARIABLE FREQUENCY DRIVE WEATHER PROTECTED TRANSFORMER REFER TO N.E.C. REFER TO N.E.C. LI1Db1O 11 D ATE Sri EN DATE F-22 WORK ROOM W1208311 DIR GROUP AVERY 06.26.12 RECORD DRAWING W1208311 DLR GROUP AVERY 10.19.12 ADC PRECISION 5—AXIS GANTRY MILL 16015520 CASNE DAT 07.16.14 RECORD SET 16015520 CASNE DAT 10.23.15 A ADC THERMOPLASTICS AFP D33205-01 DIR GROUP DMG 06.28.17 g,LAnsmczArc. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ORNAN D.HAMMOND DATE tHECKEU J.HAMLIN SUBTITLE ELECTRICAL SYMBOLS & LEGEND CURRENT REVISION SYMBOL D33205-01 SATE 06.28.17 APPROVED BY DEPT. DATE LNUINEEN D.HAMMOND CHECKED D.HAMMOND APPROVED J.KOKOCZKA APPROVED D.sEPTELKA 10.21.94 ELECTRICAL MASTER ADC THERMOPLASTICS AFP BUILDING 09-101 DEV. CENTER, WA SHEET El JOB NO. COMP N0. 040 09-101-E1 DLR Group ISSUE FOR CONSTRUCTION 06.28.17 C �I PARTIAL LIGHTING PLAN C.) SCALE: 1/8"=1'-0" REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC NOV 0 7 2017 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS 09-101—HBE42 LA ‘16, # 13 0 tic __ LEGEND GENERAL NOTES 1. ALL CONDUIT TO BE 3i"E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING TO CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600—VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LFT BUS IN PNL) BLACK BROWN "B" PHASE (CTR BUS IN PNL) RED ORANGE "C" PHASE (RHT BUS IN PNL) BLUE YELLOW NFUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAYS. 6. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7. LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION, 8. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS SEE DWG. /109-1018-2001-E180 FOR 1101090 SCHEDULE AND SYMBOL UST. CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA i...' r 1 2017 PERMIT CENTER 00(000 0 0 0 1E10 1E40 9-101.1 KEY PLAN 1.1 SYM A REASON REDRAWN FROM 109-1018-2002-013 ADC THERMOPLASTICS AFP D33205-01 EY R.RIVERA DLR GROUP APPROVED J. VAVREK DMO SYM REVISION BY APPROVED 1-19-98 06.28.17 g)LATAMEZAW'• ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R. RNERA DATE 11-21-97 SUBTITLE LIGHTING CURRENT REVISION SYMBOL D33205-01 A DATE 06.28.17 APPROVED BY DEPT. DATE ENGTNLAN CHECKED APPROVED APPROVED TITLE ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 COL S—W/21-22 DEV. CENTER, WA SHEET 1 E42 JOB N0. COMP N0. DWG N0. 09-101-1E42 i T DLR Group ISSUE FOR CONSTRUCTION 06.28.17 PARTIAL 1ST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" TO FREE EXIT SIGI XXA23-1 9 -101 - ER E48� REVIEWED FOR PLIANCE WITH FPA 70 -NEC LEGEND GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2° EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS 1 1 > 9-101-1E93## 1 9 > AND SYMBOL 0 ST101B-2001-E180 FOR FIXTURE SCHEDULE RECEIVED CONSTRUCCM 4 TEITKWILA r .. , - 1 e Lr:Ai7 NOV 07 2011 City of Tukwila BUILDING DIVISIO CAge 6`64110 NINO PERMIT CENTER T9 00•0 0 © 0 0 1E10 1111®®®M ®0112® 1E20 ® m Elm; 0 9- 01.1 KEY PLAN O H- 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" BENSON REDRAWN FROM 109-1018-2002-E14 TIMES AND LIGHTS (SEA LAUNCH) MODIFY AREA AS REQUESTED SEA LAUNCH RELOCATION - REMOVALS SEA LAUNCH PHASE 4 J#54677500 J#54698700 11713309 BY RNERA SANTOS SANTOS VAVREK WH APPROVED DATE SYM REVISION VAVREK VAVREK VAVREK VAVREK MAS 1/20/98 DC FREEZER ADDRION J116262 11/30/04 2/17/05 03.28.11 0 DC FREEZER ADDINON - RECORD DRAWING J#16262 AS BUILT ADC THERMOPLASTICS AFP D33205-01 WH WH VAVREK DLR GROUP APPROVED MAS MAS VAVREK OMG DATE 04.13.12 05.07.14 11.14.13 06.28.17 11.08.11 g)LATAFEZAW ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CAD CH KED P.C. DATE 8-27-85 SUBTITLE LIGHTING CURRENT REVISION D33205-01 SYN801 G DATE 06.28.17 50001104 JOHN J. VAVREK 'CHECKED 08.27.85 JOHN APPROVED JOHN 08.27.85 APPROVED T E ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL. W -Z/21-22 D.C. SHEET 1 E43 J08 N0. 11713309 CONP N0. 0WO NO. 09-101-1E43 TO SW.122, SEE 1E145 PARTIAL LIGHTING PLAN 0 SCALE: 1/8" DLR Group ISSUE FOR CONSTRUCTION 06.28.17 REVIEWEFIOP COMPLIANCE VITH NFPA 70 - NEC NOV 0 7 2011 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTES 1. ALL CONDUIT TO BE i"E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING TO CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LFT BUS IN PNL) BLACK BROWN "0" PHASE (CTR BUS IN PNL) RED ORANGE "C" PHASE (RHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 6. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7. LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS 19 > SEE DWG. 1109-1018-2001-E180 FOR FIXTURE SCHEDULE AND SYMBOL UST. REFERENCE DRAWINGS Y?JIS&I1 O:V1 CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA J� - 27 PERMIT CENTER 0000.0 0 0 0 0 ®®®®® CI®CIOm© ® 1E23 1014 1025 M® 1:11:1 CIF' ®® .1112l111,m®m DEEM®®® _ 9-1011.1 KEY PLAN O SCA REVISION REDRAWN FROM 109-1018-2002-E15 INSTALL DLR LIGHTS RELAMP COLUMN UNE 23 FIXTURES ADC THERMOPLASTICS AFP 12124124 033205-01 80 R RIVERA DELUNGER ESBROOK DLR GROUP APPROVED DAZE REVISION BY APPROVED DATE 02.04.98 VAVREK TAE DMG 8.17.11 10.14.13 06.28.17 ce;LA r17.ZAVG® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE DRAWN CAD CHECKED P.C. DATE 8-27-85 SUEORLE LIGHTING CURRENT REVISION D33205-01 SYMBOL D DATE 06.28.17 CINLOH CHECKED APPROVED APPROVED TIRE ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL. S -W/22-23 DEV. CENTER, WA SHEET 1 E45 JOB 140. COMP N0. 0WG N0. 09-101-1E45 0 0 XT22-1/2 a 120V BUSS PLUG 116 /0a,0b 3/4"C, (3) #10 AFF PARTIAL LIGHTING PLAN SCALE: 1/8"=1'-O" l'IDLR Group ISSUE FOR CONSTRUCTION 06.28.17 T22 -4/28b 120V BUSS PLUG XX /0b 3/4"C, (2) #10 (SEE SHEET E96) REVIEWED .FCR COMPLIANCE WITH NFPA 70 - NEC NOV 0 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 1 2017 RERNIIT CENTER .01fIK- og'io LL(LNU 1) 1 2 LAMP, 1x8 FLUORESCENT FIXTURE ® 2 LAMP, 1x8 FLUORESCENT FIXTURE, EMERG. 2 LAMP, 2x4 FLOURESCENT FIXTURE ® 2 LAMP, 2x4 FLUORESCENT FIXTURE, EMERG. 2 LAMP, 1x4, FLUORESCENT FIXTURE • METAL HALIDE FIXTURE • LIGHT, INCANDESCENT ® EXIT LIGHT I-® EXIT LIGHT, WALL MOUNT $Lv SINGLE POLE SWITCH, LOW VOLTAGE Q JUNCTION BOX ® 277/480 POWER PANEL RELAY PANEL LOV VOLTAGE CONDUIT/CABLE RUN ® J -BOX WITH LOW VOLTAGE RELAY • J -BOX WITH X LOW VOLTAGE RELAYS O J -BOX WITH LOW VOLTAGE TRANSFORMER I°I GENERAL NOTES 1. CONDUIT SHOWN SHALL BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 480Y/277V 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTOR®WN WHICH DO NOT HAVE APPROPRIATELY COLOREDORANGE INSULATION WITH COLOR TAPE WHEREVER CONL4EEEOf8S ARE ACCESSIBLE. IDENTIFY INSULATED GROUND GRAY CONDUCTORS PER NEC 250-57(b) EXCEPTION GREEN #1,6 OR c (USING TAPE). COLOR CODE AS FOGR ,T�1"SEL* 208Y/120V A 0 (LEFT BUS IN PNL) BLACK B 0((CENTER BUS IN PNL) RED C 0 RIGHT BUS IN PNL) BLUE NEUTRAL WHITE EQUIPMENT GROUND GREEN ISOLATED GROUND GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. REFERENCE DRAWINGS E> SEE DWG. f109 -1018-2001-E180 FCR FIXTURE SCHEDULE AND SYMBOL UST. CONSTRUCTION NOTES O© 0•00 O O 0 0 1E10 ®®®® tE20 ® _ 11111111111111:1131 CIEIC®®® ametumizars ® 1E10 ®M z 44 9-101.1 KEY PLAN sme xoxc P' 'I I nI�U S?M A 8 C D E REVISION REDRAWN FROM 109-10113-202—E16 IMPROVE FACTORY LIGHTING ADD PWR, AIR, & HK VACUUM INSTALL EXIT LIGHTS RELOCATE DEV TEST — IFC WH_11047.006 545662-00 546111-00 12124124 BY RIVERA AKC AKC DELLINGER WH APPROVED DATE VAVREK VAVREK VAVREK VAVREK MAS 1/21/98 5/11/04 6/8/04 SYM G H REVISION APPROVED DATE REDLINES CDO1 RELAMP COLUMN UNE 23 FIXTURES ADC THERMOPLASTICS AFP 11047.006NC D33205-01 WH ESBROOK DLR GROUP LEG TAE DMG 12.19.11 10.14.13 06.28.17 8/17/11 06.22.11 prd7A,,A • ACCEPTABILITY IRIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CAD CHECKED P.C. WWNEIN CHECKED DATE 8-27-85 8-27-85 SUBTIRE LIGHTING CURRENT RDASKXN D33205-01 SYMBOL H DATE 06.28.17 APPROVED APPROVED ELECTRICAL MASTER ADC THERMOPLASTICS AFP BUILDING 09-101 COL. W -Z/22-23 DEV. CENTER, WA SHEET 1 E46 JOB N0. 54611100 COUP N0. DWG N0. 09-101-1E46 3/4"C.O. ABANDONED IN SLAB SEE 1E87 �L= H7 L DLR Group IN SLAB OVER TUNNEL 4 -x x— Y- 0 ISSUE FOR CONSTRUCTION 06.28.17 C37c 3/4'C.O. ABANDONED IN SLAB SEE 1E8 t- 3/4"C.O. IN SLAB OVER TUNNEL LJ 11> y� I/2'RS, 2/12,1/12GRD. II IC07 __SEE 1F95 LC72b LC72D 4 3/4 C.O. ABA DONED IN LI SLA SEE 1E87 3/4'C.O. IN SLAB OVER TUNNEL 3/4'C.O. IN SLAB OVER TUNNEL 104 LC72b LC72b 204 20A 1/2.25, 2112,1f120RD. LC72a SEE 1E95 2'C, 202,1E120RD. 72a SEE 1E95 PLAN LC93c 3/4•RS, 2112,112CR LC1D2b SCALE: 1/8" = 1'-0" 1/2'RS, 112 LC1026 SEE 1E95 3/4'RS, 2112,112GRD LC93c SEE 1E95 n� H IH 1 f n n 9 f n n n n n L LC126b 1/2'RS, 112 LC126b 1/2'RS, 112 SEE 11E— LC126b REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC NOV 07 2017 LEGEND: N ED ffi E25304 Mmx PA 0 D7 ▪ npf 15A, 125V, 1 PHASE DUPLEX RECEPTACLE 20A, 125V, 1 PHASE DUPLEX RECEPTACLE 15A, 1258, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE DROP 30A, 125V, 1 PHASE, TIWSTLOCK RECEPTACLE 150, 1258, 1 PHASE 4—PLEX RECEPTACLE 300, 120/208V, 3 PHASE RECEPTACLE 15A, 125V, 1 PHASE, 4—PLEX POWER POLE DATA P011 SINGLE POLE TOGGLE SWATCH 120/2088 DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN DISCONNECT SWITCH, NON—FUSED, XX AMPERES MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL 115V MOTOR (SIZE AS NOTED) 208 OR 2300 MOTOR (SIZE AS NOTED) GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS 01HERMSE NOTED. 2.) ALL WIRE TO BE /12 1HNN UNLESS OTHERYASE NOTED. 3.) 111E FOLLOWING COLOR CODING CF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 120/2060 277/4800 '6' PHASE LEFT BUS N PANEL) BLACK BROWN 'B' PPPHHHAAA.S.E CENTER BUS IN PANEL) RED ORANGE NEU'080 RIGHT 805 N PANEL) 611E 14108 WHITE CRAY EQUIPMENT GROUND GREEN 4.) LARGE SZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOO CN SHEETS 12 AND E3. 7.) DYMO LABEL ALL RECEPTACLES JUNCTION BOXES, SWITCHES ETC., WIN CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS- 11 RAWINGS:I1 >FOR 120V SERVICE IN TUNNEL SEE 9-101—TNE92. CONSTRUCTION NOTES: City of Tukwila BUILDING DIVISION RECEIVE CITY OF T UK WILA 2 PERMIT CENTER 1E60 1E61 1E62 1E63 1E64 1E65 1E66 1E67 1E68 1E69 1E70 1E71 1E72 1E73 1E74 1E75 1E76 1E77 1E78 1E79 1E80 1E81 1E82 1E83 1E94 1E85 1E86 1E87 1E88 —® 1E89 1E90 1E91 1E93 194 1E95 1E96 9-101.1 KEY PLAN VIII 11111 NII II. 8094 M N 0 REVISION CTLM 9 & 10 — IFC WH_11047.017 ADC INSTALL PWR. & INSRTR VACUUM W1563890 AS BUILT 14210870 ADC THERMOPLASTICS AFP 033205-01 er WH WH 5AZAN VAVREK DLR GROUP APPROVED DATE SRM SRM SL VAVREK DMG 07.06.12 04.01.13 04.22.13 SYM G H REVISION 10.08.13 06.28.17 FAB AREA — IFC WH_11047.017 CTLM WORKSTATIONS — 9010 IFR WH_11047.027 C LLM WORKSTATIONS — F1C WH_11047.027 REDUNES CD05 11047.017 NC CTUA 9 & 10 — 9010 IFR WH_11047.031 BY WH WH WH WH WH APPROVED DATE MAS SRM SSRM LEG SRM 11.17.11 04.19.12 04.26.12 05.07.12 06.26.12 gi__ArzrzAirc® ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED 'DHAWN KYLE HO CHECKED DATE 9-8-98 SUBIDLE 120V/208Y POWER CURR17.10 REVISION D33205-01 SYMBOL 0 DATE 06.28.17 APPROVED BY DEPT. DATE LNUINLEH KYLE HO 6-9-98 CHECKED JOHN J. VAVREK 6-10-98 APPROVED APPROVED JOHN J. VAVREK 6-10-98 TITLE ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL S—W/21-22 DEV. CENTER, WA SHEET 1 E92 JOB N0. COMP N0. DWG N0. 09-101-1E92 SYM G COVER(TYP.) �(1 ORA —__4 A�° ��r:i/ ,r ..IiP// • +18'330 SEE DWG. 1E88 FOR CONTINUATION pr ----3/4"R. 4/12 114"CA. 1 4 > Q PULL SIRIN/I TT 3/4"R III II TUNNEL C 45c SEE DWG. 1E88 FOR CONPNUAI1OONN 558 1142C.01 `CJ STRING `• 1 . : 3/4",2j12 3/4',3/12 UP TO BRIDLE RING AT 2ND LANDING 3/4"C, NW CABLES SEE 1E91 LC1a +40° AFF 7 1 -1 I J -a I I -1 ¢,-_1/2'RS, 21121/12GRD. LC29c SEE 1E92 -1 LC2a,c DEAD ENDED LC2b _1 LC1a +40" AFF ii/ -3/4',4112 3/4'C 3/4',4/12 T22-6/3 TRUSS LEVEL PLATFORM a c`7n NW CABLES 3)010 1P20 UP LC81a 1/2 RS, 2112,11120RD. L£$1CI / LC37c SEE 1092 UNISTRUT BRIDGE UP LC81c 0--0 LC81 b -1 I I E -I h 1/2'RS, 2j12,1/12GRD.^� LC72c SEE 1E92 C37b 3/4'R, 4012.1112GRC LC72c IU /2"C, 2/12,1/12GRD. C72b SEE 1E92 /2(R, 2/12,1i12GRD LC 2b LC72c +12"AFF 1/2'RS, /12 LC102b SEE 1E92 LC102b LC101 DEAD ENDED 3/4'RS 2/12, 112GRD LC93c SEE 1E92 IJ I 4#1 1/2"C, 3#12 C102c 1/2"RS 1i2 LC102a LC93a 3/4"c, 6/12.1/12GRD-e 3/4'12,6/12.1/1 2))1P20 1029 L,C30 1)1930 3)1P20(3) P20 LC38b LC38a 1038 1920 P20 SP T22-5/28 1 I ` I M9 _" �t " SII 20 a 30A , 3/4'C, 112 3/0, C, j12 WP CFO a I 3/4'R, 2112.1/12GR I I (33)1P20 DED,EPIC SYSTEM DLR Group ISSUE FOR CONSTRUCTION 06.28.17 P20 2KW,277V,IPH,8' BASEBOARD 11115 b PH DEAD PH DEAD 3/4'125, 2/12, 112CRD C71b LOCATED ON CTLM COLUMN (8 TYP) WIRELESS ANTENNA CONTROL BOX 16"x20° Wel 1P201 'Emma. ill 1/111112111114 DN, IN WALL ( 3/4°C, #1 `f,79 (3)1920 1-1/2$, 4/1/0 LC93b g 1 -1 LC102c 1 1 I J I I 1#10 GRD. LC102c r12"AFF 3/4"RS, 4/12, n I LC93b & LC93c 3/4"C, 4#12, 1/2"15, /12 20120 5#10 .,,, +12"AFF. LC102a jl 3/4 S, 6112, 1120RD 020 0 0 13)1P20 r (1)3930 100 AMP PLUG-IN BUSWAY, 120/208V 30, 4WIRE (3)1P20 ``G011 0C{{IIII 0)3`9030 `f, (3)10020 (3)1P2D (3)1P20 ��(3)12. _�ri■ssssss�ri;a i�:::��s1E�._as�Z LC126b -�� 1/2"RS, 2/12 .11%„O 10125 DEAD ENDED 1/2'RS 2/12 28 3.30 LC126a 3/4"c, 4j1O & 1/10 GRD. LC126c 3/4"RS, 4/10 & 1/10 CRO. 3/41 , EMPTY Ir 3/4'R, 4110,412 & 1/I) GRD. I 3/4"C, 4/10 &1/10 CRD. 3/4"C LC13 CIRCLE AW j6641 +18"AFF LC126a - OLT LASER PWR. CONTROL CABINET 1'125, 4110 & 1p0 GRD. /12'C, 8110,21'2 110 GRD. X7 NETWORK CABINET UP P LAN SCALE: 1/8" = 1'-0" 0 51804 LASER ROOM 1) 3P30A IKW,277V,SPH,4' 3/4"C, 4/10, 1/10 ORD. BASEBOARD 618 T22-5/26 FAN RF -2, 1/8HP,120V, LC126a, MTD. 21' AFF A/0(1/10 REVIOWEU FOR UNFPA 0 NECTH NOV 07 2017 City of Tukwila BUILDING DIVISION. LEGEND hj l7 A 0 150, 1250, 1 PHASE, DUPLEX RECEPTACLE 200, 125V, 1 PHASE DUPLEX RECEPTACLE 150, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) 150, 1250, 1 PHASE, DUPLEX RECEPTACLE DROP 300, 1250, 1 PHASE, TWISTLOCK RECEPTACLE 15A, 1250, 1 PHASE, 4-PLEX RECEPTACLE 300, 120/2080, 3 PHASE RECEPTACLE 15A, 125V, 1 PHASE, 4-PLEX POWER POLE DATA POLE SINGLE POLE TOGGLE SWITCH 120/2080 01011061111011 PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE A5 SHOWN DISCONNECT SWITCH, NON-FUSED, XX AMPERES MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL 115V MOTOR (SIZE AS NOTED) 208 OR 2300 MOTOR (SIZE AS NOTED) GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS 0111ERWi5E NOTED. 2.) All WIRE TO BE 112 ROW UNLESS 01HERYASE NOTED. 3.) ^'E 1011.016910 DOLOR 00011111:1 CONDUCTORS 91016 BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 120/2080 277/4800 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B' PHASE (CENTER BUS IN PANEL) RED ORANGE PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS 511ALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY CCLORE) TAPE 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS 500551 ON SHEETS E2 AND 03. 7.) DY1,10 LABEL ALL RECEPTACLES, JUNCTION 605ES, SWITCHES, ETC., 11111 CIRCUIT DENDFICA11ON. 8.) INSTALL REVISED PANEL SOS0000ES UPON COMPLETION OF JOB. REFERENCE DRAWINGS CONSTRUCTION NOTES D RECEIVED CITY OF TUKWILA PERMIT CENTER P 0 E60 1E61 1E62 568 1E65 1E68 1E67 1E60 IE69 1E70 1E72 1E73 1E74 1E75 1E76 1E77 1E73 (079 1080 1E81 1E82 1E63 J (165 1066 1E67 1E 1E89 1E93 (692 100.3 08 0 4' PLAN SCALE: NTS 1806 O RFVMON CILIA 9 & 10 - 90Z 106 CTLAI 9 & 10 - IFC ADC INSTAL PWR k INSTR. VACUUM 115 BUILT APPROVED DATE W1_11047.031 WH_11047.031 W156890 14210870 WH WH W1 SAZAN VAVREK SRM SRM SRM SL VAVREK 06.28.12 07.06.12 04.01.13 04.22.13 10.08.13 ZM A B C D REVISION REMOVE CTLM#12 GANTRY, PILLARS, ETC W1832481 INSTALL PLANT AIR & 1200 AT V23 W2342325 RELOCATE AGF1440 22279-20 INSTALL POWER k DATA OUTLETS AT 123 C154370 ADC THERMOPLASTICS AFP D33205-01 SAZAN VAVREK EISI SANIDAD DLR GROUP APPR0450 SL VAVREK D.O. SANIDAD CMG DATE 10.15.13 11.25.13 02.07.14 10.05.15 06.28.17 g)LAirAweisece ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHESTERFIELD CHECKED MTE 10/13/94 SUBTILE 120V/277Y POWER CURRENT REVISION D33205-01 SYMBO1 D MATE 06.28.17 /ENGINLLH DARCY CHECKED VAVREK 10/13/94 10/17/94 APPROVED APPROVED MENTA 10/17/94 TIRE ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL. W -S/22-23 DEV. CENTER, WA SHEET 1 E95 JO0 N0. 1001715343 COMP N0. DWG N0. 09-101-1E95 3/4"C,4i10 L 46abc LD48a 11 L028a,b & Q DEAD ENDED r -T - L_1_ 3/4"C,3j10 LD1177bc 11 Lona ` I W0109/abc, L0120bc 3/4" 7110 1 1 3/4',3(12 47c I LIMO 1'4-3/4" 2/10 ID105b 15c L087a,b & c DEAD ENDED IN FIR CHASE L01056 0/b 47b WIRELESS ANTENNA CONTROL BOX 16"x20" 41 3/4' 6/10 TO LD113abc L045o 3/4',4/12 FLIPPER TOOL TOOL CONTROL a50b EAD ENDED N FLR CHASE (43/4" EMT 1-4-3/4- 3/10 3/4" 6/10 TO LD103abc 3/4" 6/10 -' 1D105abc 3/4' ,0 1 c 47a 022-6/4 TRUSS IEKE PLAWgd1 SEE DWG 1E79 & E5 DEAD ENDED ON WEST 0611 13'xN 10',TREND9•I 3. J� L L n L 3/4",6/10,#12G n .L 1 3/4" 2810 1 TO 10110 3/4' 4/10 3/4" 3/10 J 4114 114 (3)20A1P 10740 1D740 LABELED 'LD' 100 AMP PLUG -WV BUSWAY, 120/2080, 30, 4 W9E 10111 (3)20A,1P PLAN SCALE: 1/8" = 1.-0" DLR Group ISSUE FOR CONSTRUCTION 06.28.17 12 /2' 4110 10113c LDI030•c NEWA7RN CABINET AIITOIRONIS 1/2" 3110 11100 11000 3/4' 4j10 101200 3/4 4, 4110, N 5}B REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC NOV 0 7 2017 City of Tukwila BUILDING DIVISION P 0 0 0 0 1060 1E51 1E62 1E63 1064 1E65 1E66 1E67 1E68 1E69 1E70 1E71 1072 E73 1E74 1E75 1E76 1E77 1078 1079 1E80 1E81 1E22 1E83 r 1084 1E89 1085 1E40 1066 1E87 1E88 0 0 0 0 10 1E51 1E92 1E93 194 1E95 1 101.1 KEY PLAN I, '4 ICI bm 4 F43 0 LEGEND 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE 20A, 125V, 1 PHASE DUPLEX RECEPTACLE 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) 150, 1250, 1 PHASE, DUPLEX RECEPTACLE DROP 30A, 125V, 1 PHASE, TVISTLOCK RECEPTACLE 15A, 125V, 1 PHASE, 4-PLEX RECEPTACLE 30A 30A, 208V, 1 PHASE RECEPTACLE, #2620 15A, 125V, 1 PHASE, 4-PLEX POWER POLE DATA POLE SINGLE POLE TOGGLE SWITCH 120/208V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN DISCONNECT SWITCH, NON-FUSED, XX AMPERES MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL 115V MOTOR (SIZE AS NOTED) 208 OR 2307 MOTOR (SIZE AS NOTED) MACHINE/EQUIPMENT NUMBER x, y HORSEPOWER GENERAL NOTES 1. CONDUIT SHOWN SHALL BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. REFERENCE DRAWINGS: 1 1 > 9-101-1E96 9-101-1E43 3 9-101-1E511 1 4 > 9-101-1E68 5 > FOR TUNNEL SERVICE SEE 9-101-TNE93 CONSTRUCTION NO ES I PROVIDE NEW 20A/1P BUS PLUG FOR EQUIPMENT CONNECTION. RECEIVED CITY OF TUKWILA �•�fC 7 2317 PERMIT CENTER m REVISION 6Y APPROVED DATE RENSION W X Y A AS BUILT REMOVE CT1.11#12 GANTRY, PILLARS, ETC ZENITH AREA 1 - CLEAN ROOM ZENRH AREA 1 REMOVAL INSTALL (6) STATIONS W/PWR & NEIWK 14210870 W1832481 16-306-22 15653180 W2807033 VAVREK WAN as VAVREK VAVREK VAVREK SL VAVREK VAVREK VAVEK 10.08.13 10.15.13 10.17.13 02.04.14 06.05.14 B s T U V ADC THERMOPLASTICS AEP REDLINES CD01 NC/OS NC INSTALL SYSTEMS FKURNITURE 033205-01 11047.006 12876958 LITILIIY RELOC FOR DC FREEZER - 909" ADC 61 DLR GROUP WH ESBROOK WH WH APPROVED DMG LEG VAVREK MAS MAS DATE 06.28.17 12.19.11 02.28.12 10.26.12 04.01.13 g)LA WZAW e ACCEPTABILITY THIS 0ESICN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. CHESTERFIELD CHECKED DATE 10/13/94 SU67711E 120V/208Y POWER CURRENT RENSION D33205-01 SYMBOL B DATE 06.28.17 KEN DARCY CHECKED 10/13/94 APPROVED APPROVED NAREN MEHTA 10/17/94 TITLE ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 COL. W -Z/22-23 DEV. CENTER, WA SHEET 1 E96 JOB N0. 54677500 COMP N0. DWG N0. 09-101-1E96 ___u liDLR Group 1-1/4"RS, C.O. SEE DWG. 1E137 —CONDENSATE RETURN PUMPS #CRU1a & CRU1b ON ALTERNTOR. 1/3HP EACH. I 1 l3 f-1"RS, 6#12 SEE DWG. 1E145 ISSUE FOR CONSTRUCTION 06.28.17 4 X- x r1-1/4"RS, C.O. SEE DWG. 1E137 n i 1-1039 3/4"C, 3#6 TO HB39 x SEEx1E145 Tf- 6 CINN—MILACRON TAPE REEL LOADER #1 & #2 (2)10FLA n ~1 R n I� 4 n W kr »As n 3/4"C, 3#12,#12G 3/4"C, 3#12,#12G TO HC20 SEE 1E145 3/4"C, 6#10,#10G TO 1-1838 & H837 VIA PULLBOX AT V.5/23 SEE DWG. 1E145 PLAN SCALE: 1/8" = 1'-0" Fn LEGEND ® 480 VOLT DROP-3—WIRE, 4—POLE CROUSE n HINDS TYPE APR, XX APMERES. Ni" 480 VOLT RECEPT., 3—WIRE 4—POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. O J—BOX ® 480/277V DISTRIBUTION PANEL A TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND • 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC ITEM MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH IN MOTOR STARTER, MANUAL ' /KCJ DISCONNECT SWITCH, NON—FUSED, XX AMPERES • MACHINE/EOUIPMENT NUMBER X, Y HORSEPOWER GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 1HHN/T01% UNLESS OTHERWISE NOTED. 3.) 111E FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4800 PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B' PHASE CENTER BUS IN PANEL) RED ORANGE "C' PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WI08 DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER INSOLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS 11 > SEE DWG. 9-101–TNE142. REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC NOV 07 2017 City of Tukwila BUILDING DIVISION__ QS, b CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA `I L� ro7 PERMIT CENTER 16110 1E111 16112 1E113 1E114 16115 1E116 1E117 1E118 1E119 1E120 1E121 1E122 1E123 1E124 1E125 1E126 1E127 1E128 1E129 1E130 1E131 1E132 1E133 1E134 1E135 1E136 1E137 1E139 1E140 1E141 1E138 1E143 1144 1E145 1E146 9-101.1 KEY PLAN IIIII III SYN A B C D REVISION DISASSEMBLE CTI.M MACHINE POWER ISLAND 4—PLD OUTLETS APPROVED DATE 10146708 CTLM TAPE REEL — IFC REDUNES CD05 ADC WH_11047.018 11047.018 VAVREK ESBROOK WH WH WH VAVREK TAE MAS LEC MAS 01.18.10 05.31.11 11.14.11 STM F G H REVISION AS BUILT REMOVEL CTLM #12 GANTRY, PILLERS, ETC ADC THERMOPLASNCS AFP 14210870 W1832481 D33205-01 By VAVREK SAZAN OUR GROUP APPROVED DATE VAVREK SL DMG 10.10.13 10.15.13 06.28.17 05.14.12 04.01.13 ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE • WN EDDIE P. DUARTE CHECKED DATE 04.14.03 SUBTITLE 480Y/277V POWER CURRENT REVISION SYNBOL L� D33205-01 I DATE 06.28.17 1NHNELH JOHN J. VAVREK CHECKED 04.14.03 0. 'Ilii 141 APPROVED JOHN J. VAVREK 04.14.04 APPROVED TITLE ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL. 21-22/S–W DEV. CENTER, WA SHEET 1E142 JOB NO. CORP NO. DWG NO. 09-101-1E142 1 1/4" BJ SLAB 1 1/4" IN 8.09-1, SEE DWG. 1E138 FOR CONTINUATION SEE DWG, 1E138 FOR CONTINUATION 1\ 3/4"0#10,1 1 joi faig• HA'" 100 3/4'C,3j10,1 -}10G 1 1/4" R.C.O.1 IN WNL ROOF SLABS T 1 L DLR Group A,HU.,M" Fes,"" KA.Mm ISSUE FOR CONSTRUCTION 06.28.17 PENSION ADC OPF AT 9-101 ADC THERMOPLASTICS AFP SEA LAUNCH PHASE 4 - 905 SUBMITTALS SEA LAUNCH PHASE 4 - IFC PICKED UP REDLINES W3266018 D33205-01 WH_11045.001 WH_11045.001 EY EISI DLR GROUP WH WH WH APPROVED DATE SYM REVISION VAVREK DMG MAS MAS LEG 03.06.15 06.28.17 05.25.11 06.02.11 12.19.11 M 0 DT & E CLEAN RM. ELECTRICAL HOOKUPS ADC AS BUILT REMOVED CTLM j12 GANTRY, PILLARS ETC RECORD DWG. - FREEZER ADDITION 13030111 14210870 W1832481 16262 TUNNEL ASSEv13LY AREA 400K CLEAN ROOV 3/4"C.O. CFF nvr 1Ci4R PLAN 12> 1/8" = 1"-0" BY VAVREK WH VAVREK SA2AN WH APPROVED VAVREK MAS VAVREI( SL MAS 801E 04.10.12 04.01.13 10.15.13 10.15.13 05.07.14 F 4" C.O.FROM BUS PLUG AT COL Y SEE DWG. 1E138 FOR CONTINUO TRENCH 31P E10 I b =J� 3/4"C, 3#101100 TO HE28. SEE 1E146 g)LATAFE7AW 4"C.O. FROM BUS PLUG AT COL Y23. SEE DWG. 1E146 FOR CONTINUATION VER MOT CAL LIFT DOOR R 3HP REVI zTEI FOR COMPLIANCE WITH NEPA 70 - NEC NOV 0 7 2017 City of Tukwila UIL Il LEGEND: 49. 480 VOLT DROP-3-111RE, 4 -POLE CROUSE HINDS TYPE APR, XX APMERES. 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. • J -BOX 480/277V DISTRIBUTION PANEL • TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND • 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC DIP MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH ® MOTOR STARTER, MANUAL 'O DISCONNECT SWITCH, NON-FUSED, XX AMPERES ® MACHINE/EQUIPMENT NUMBER X, Y HORSEPOWER GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 'A' PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE 'C' PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL (914TE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE 5.) ALL UNUSED CONDUIT AND 'WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS: E SEE DWG 9-101-1E138 L� NOTE:SEE ORIGINAL DWG 9-1018-2001-054 FOR REFERENCE. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DITIMAR CHECKED D1 23/92 SUMTRE 480Y/277 VOLT POWER CONSTRUCTION NOTES: RECEIVED CITY OF TUKWILA ► .d i . 1 2 1 PERMIT CENTER O 0 00•0 ON 0 1E110 1E111 18112 1E115 1E116 1E117 1E118 1E120 MN MIME 18125IME, MIM 1E130 1E131 ®E dIEWEEMEMEICI 1E140 M®= — 0 9-101.1 KEY PLAN CURRENT REVISION D33205-01 SYMBOL S DATE 06.28.17 0 NLEH JOHN J. VAVREK CHECKED 1/27/92 APPROVED JOHN J. VAVREK APPROVED 1/27/92 TTRE ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 COL. W -Z/21-22 DEV. CENTER, WA SHEET 1E143 JOB N0. COMP N0. DWG NO. 09-101-1E143 O O i" ---TO PUMPS #CRU -1a & 1b SEE DWG 1E142 2"C.O. 2"C, 3#2/0 HB1 (L. J 1"C, 6#12 HB3 & HB4 TO LTG. SEE 1E45 H83 F184 9185 20A 20A 20A r I I I I 1 3/4"C, 3#10 H828 r 'IH821 F 2"C, 3#1/0,#6G uI HB1 1 4E111111 11 wil1l 3#1/0,0 I 1 9613 HB19 9821 HB soA 1 11150AI 2, 2"C, 3#2/0440 2C, 3 2 x 16 x 4 (14 TYP) IIIDLR Group 3/4"C, 3#6 FROM HB39 SEE 1E142 3/4"C, 3#10 3/4"C, 3#6, 3#1 TO HB39 & HB40 I NTLM L 125A ." 42 LEGEND: 480 VOLT DROP -3 -WIRE, 4 -POLE CROUSE HINDS APR XX AMP. 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, ARE XX AMP J -BOX 480/277V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 2"C, 3#2,#6GRD 2"C, 3#1,#6GRD To Bus Plug H821 H843 TO 125A NTLM 2"C, 3#1/0,#60 TO LTG. SEE 1E45 3/4"C, 3/110 HB27HB28 HB29 HB37 HB38 HB39 H84011B41 HB421 HB43 30A 304 1 311 II O1AIFOIA 11116iiienr 1-1 2 `93 Ell EnIe G 7' 6" AFF (5 TYP ISSUE FOR CONSTRUCTION 06.28.17 1-1/2", 3#1/0, #60GE ARMOUR CLAD 13UWAY 800A, 277/480V3PHS4W, 0 AFF (8 TYP) 1/2 NEUT. (2 TYP) 2"C, 3#2/0 HB44 TO CTLM#7 2"C, 3#2/0 HB44 TO CTLM#7 HB44 HB4` DA 20A 2"C, 3#2/0 HC18 TO CTLM#8 -I 2"C, 3# /0 2"C, 3#2/0 • —WI HC19 T CTLM#9 HC31 TO CTLM; 0 -I 9 9 I I I I 10 3/4"RS, 3#12,#12GRD —< 1 11 f -H 11 r r� urn HC17 , HCI8 HC19 \SER PWR. OL CABINET . 1.11PINIrmr CRANE •W' SEE 9-101- 145 PLAN SCALE: 1/8" = 1.-0" ODOR CONTROLLER 61.0, 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL DISCONNECT SWITCH, NON-FUSED, XX AMPERES GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE $12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2080 277/4800 °A° PHASE LEFT BUS IN PANEL) BLACK BROWN "6" PHASE CENTER BUS IN PANEL) RED ORANGE °C° PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF CONSTRUCTION NOTES: REVIEWED .FOR COMPLIANCE WITH ` NFPA 74 - NEC NOV 0 7 2017 City of Tukwila G DIVISION RECEIVED CITY OF TUKWILA ...,_12::7 PERMIT CENTER O 0 004,0 0 0 0 0 110 1E116 1E111 MEM ® 1EI18 MEM tan ®®MMEI® ICIEZZIM®® IMAM 1E11 -Q 9-101.1 KEY PLAN II In SYM REVISION CTLM REFURBISHMENT — 900 IFR WH_11047.29 CILIA REFURBISHMENT — IFC WH_11047.29 REDLINES CD01 NC REDLINES CD05 REDLINES CD06 11048.18 11047.029/OS 8T WH WH WH WH WH APPROVED DATE SRM SSRM LEG LEG LEG 05.03.12 05.08.12 05.14.12 05.14.12 07.20.12 SYM 0 R 5 T U REVISION ADC AS BUILT 14210870 REMOVE CTLM/12 GANTRY, PILLARS, ETC W1832481 RELOCATE AGFM40 22279-10 ADC THERMOPLASTICS AFP D33205-01 80 WH VAVREK SAZAN EISI DLR GROUP APPROVED MAS VAVREK SL D.O. DAG DATE 04.01.13 10.15.13 10.15.13 02.07.14 06.28.17 g;LAMEIvillf”® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN CHDRFIELD fITELVE 110/13/94 SUBTITLE 480Y/277V POWER CURRENT RDASION SYMBOL D33205-01 U DATE 06.28.17 APPROVED BY DEPT. DATE ENGINEER CHECKED VAVREK 10/14/94 APPROVED APPROVED METRA 10/14/94 T11LE ADC THERMOPLASTICS AFP BUILDING 09-101 ELECTRICAL MASTER COL. S -W/22-23 DEV. CENTER, WA SHEET 1E145 JOB N0. 54704700 CORP ND. DWG N0. 09-101-1E145 0 e alk GE ARMOUR CLAD BUSWAY 800A, 277 4800, 3PH, 4W, 1 2 NEUT. 2 TYP DLR Group ■ 1 1 1 1 1 1 PIg _ A r -N II r itk ori ®el I 10 MI • 2"C.O. - 2"C, 3#2/0 DEAD ENDED • • HD17 HD26 DEAD 1-1/4"C, 8) +7--3/4"C.O. ENDED—� 3#2, #6G �l•�0H•aa 11L �r II F-1 J 1 DSTWNL IN 1REN01 10"00•.61 1 L L 314/0,//20 1 1/4",3123" HD22 11026 16028 11029 HD30 El CM IElElL HD -1/4"C, 312,120 n 3/4"R EMPTY I r JI 7I 11 r--r- L-1- r T fl I/, --TRENCH 3/4"C, 3#10,#10G HE48 307 (DATT CHARGER) I --141c (BATT CHARGER) VACUUM PUMP 7.5HP HE2/�H 1 i g— Ia....9 .HEATER 3/4"C, 3#10,#1)G 3/4"C, 3#12,# 25- 3/4°C, 3#10,#100 1X23/3 ASSEMBLY AREA 400K CLEAN ROOM 11--1 1/2"C.o. J HD41 HD42 2"C.0 440.44,41K PImiW 6 —50; 006 El II calor 01 r L I 3/4"C, 3/10,1100 •1 TO HD28 & 11030 1 1 1 1 1E2 --�11111111■WAIII._ 1-1/2"C,3#2,#6G 1E1461E142 7'-6" AFF ISSUE FOR CONSTRUCTION 06.28.17 30" AFF(2 TYP) PNL 1023 (N EMERG. PNL) 1-1/4"C, 3/2,160 CONDUIT IN WALL PLAN l 9:11111 jLr::■ r - n I L J, uiE ._ 11E17 w 11E51 E� HE49 C HE J 3/4 C,3#1 3> n -O -rl -n 33 MEP Z7 HE25 X100 60 4 1E146 E142 G.E. ARMOR -CLAD 800 AMP PLUG-IN BUSWAY, 480/277V, 30, 4W, 1/2 N 601 ■ ■ 1, 3/4"C, 3#10,#10G TO VERTICAL LIFT DOOR AT COL Z20. SEE 1E143 US DUCT "HE" GE, 3 ph, 3 Wire EQUIPMENT WAS DISCONNECTED SPARE DISCONNECT SWITCH OFF POSITION 7'-6" AFF SCALE: 1/8" = 1'-0" /4"C.O. T01 -1/2"C,3#4,#85 SOUTH BLADE FORMER NORTH BLADE FORMER ONDUIT IN WALL PULLBOX ® 40° AFF (2 60 1 "C,3#4,#8G TO 14029 tel(1:0f LEGEND: @ 480 VOLT DROP -3 -WIRE, 4 -POLE CROUSE " HINDS TYPE APR, XX APMERES. 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. O J -BOX ® 480/277V DISTRIBUTION PANEL A TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC a. MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH M MOTOR STARTER, MANUAL m,49I O DISCONNECT SWITCH, NON-FUSED, XX AMPERES MACHINE/EQUIPMENT NUMBER X, Y HORSEPOWER 0 GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON All CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4806 "A" PHASELEFT BUS IN PANEL) BLACK BROWN '8' PHASE (CENTER BUS IN PANEL) 900 ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) All UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF J08. CONSTRUCTION NOTES: PROVIDE NEW 3P BUS PLUG OF INDICATED AMPERAGE FOR EQUIPMENT CONNECTION. REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC NOV 0 7 2017 City of Tukwila VISION RECEIVED CITY OF TUKWILA t wry" PERMIT CENTER 0 000•0 0 0 0 0 I 0 1E112 ®® 10115 10118 10120 1E121 ®®.® tE122 1E125 E® 10130 10131 ® 1E133 tE1400140 0 i1 1E110 1E111 1E116 1E117 9-101.1 KEY PLAN 4982 A REVISION AUTO STRINGER REVISED AS BUILT ADC THERMOPLASTICS AFP DT & E CLEAN RM ELECTRICAL HOOKUPS ADC W16160449 17211733 033205-01 BY CEI VAVREK DLR GROUP VAVREK WH 13030111 APPROVED DATE PWJ VAVREK DMG VAVREK MAS 12.04.14 01.20.15 06.28.17 04.10.12 04.01.13 SYM V W X Y REVISION AS BUILT ZENITH AREA 1 - CLEAN ROOM REMOVE ZENITH AREA 1 RECORD DWG. - FREEZER ADDITION STACKER CHARGING UNIT REMOVAL 14210870 16306-22 15653180 16262 W2952232 BY VAVREK EISA VAVREK WH VAVREK APPROVED VAVREK VAVREK VAVREK MAS VAVEK DATE 10.15.13 10.17.13 02.03.14 05.07.14 08.29.14 BOE/A/G® ACCEPTABILITY 11115 DESIGN ANO/OR SPECIFICATION 15 APPROVED DRAWN D CHESTERFIELD CHECKED DAM 0/13/94 520/1/50 480Y/277V POWER CURRENT REVISION D33205-01 SYMBOL DATE 06.28.17 APPROVED BY DEPT. DATE NLLN CHECKED J VAVREK APPROVED 10/14/94 APPROVED NAREN MENTA 10/14/94 TITLE ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 COL. W -Z/22-23 DEV. CENTER, WA SHEET 1E146 JOB NO COMP N0. DWG N0. 09-101-1E146 11> 480 V, 2400 A 3 PH. 4 WIRE (40. NC) TO SUBSTATION 73 u UNE 7 UNE 1 9KV TO 1600 A SUB 73/74 TIE BREAKER T 74F6 74E5 800 AFT 800 AF 4. GE AXR -60-3004, 300 AT GE AKR-6D-30H MICROVERSATRIP MICROVERSATWP LT P/U=0.9C LT P/U=0.83C LT DELAY=2 LT DEIAY=2 ST P/U=2.5C ST P/U=3.0C ST DELAY=MIN 12T OUT ST DELAY=MIN 121 OUT INST=6X INST.=4X (2)31500MCM,2/250MCM (z)3j2509CM,/20 r�USCA BUS DUCT HC 800/* * 3 PH, 4W W -Y/23 1X23 225/225 3 PH, 3W (NOT AN EMER. PNL) L DLR Group THERMOPLASTICS USER 400AF 125AT 9770A 3PH FAULT EMERGENCY FEED XR22/abc ISSUE FOR CONSTRUCTION 06.28.17 (2)41350MCM GEN ROOM T 74F4 800 AT 600 AT 4. GE AK0-60-300 MICROVERSATRIP LT P/U=1.0C LT DELAY=2 ST 1/0=3.0C ST DELAY=MIN 12T OUT INST=80 (2)41350MCM ATS 118 ///8////, XR22-1 600/MLO 3 PH, 4W A LL--1)30KVA 208Y/120V 2' 411 XR22-2 100/100 .— 4/1/0 /////, XT22-1 150/150 3PH. 4W TRUSS, T22 (2)4/350MCM T 74F3 800 AF 600 AT y GE AXR -65-300 MICROVERSATRIP LT P/U=1.0C LT DELAY=2 ST P/U=3.0C ST DELAY=MIN 12T OUT INST=8X 600/600 3 PH, 4W 9106 86201 L"u30KVA 2081/120V 2' 4/1/0 XT22-2 100/100 3 PH, 4Y TRUSS, T22 74F2 800 AF 600 AT �. GE AKR-60-300 MICROVERSATRIP LT P/U=1.0C LT OEU0Y=3 ST P/U=9.00 5T DELAY=INT 121 OUT INST: 10X HUSTLE MACHINE T 74F1 800 AF 320 AT 4, CE AKR-60-300 MICROVERSATRIP LT P/U=0.60 LT DELAY=2 ST P/U=3.0C ST DELAY=MIN I2T OUT INST=80 31500MCM & 114 GRD. cu 7(1T (2)4/500MCM,114/0 —d T 1225 KVA 2081/1200 122-6 800/800 3 PH, 4W TRUSS PLATFORM UST 2-1/2" 514/0 2-1/2" 514/0 BUSWAY U 100/*•• 3 PH, 4W S -W/20 ONE LINE DIAGRAM - SUBSTATION 74 BUSWAY L8 100/" 3 PH, 4W 1V -Y/20 80E T41 1500/2000 KVA (y -V-1(1 5.95 x 4807/2770 T I 11 04 1600 AF l_"_J y 1600 AT 1600:51 (3) UNE 7 } REFER TO DRAWING 109-000-2000-E4 UNE 1 3-1/2'STEEL CONDUIT 314/0, 15KV, EPR UNIT SUBSTATION 74 POWER METER PML 7650 ACM G.EAKRT-6D-5011 MICROVERSATRIP LT P/U=1.0C LT DEIAY=2 ST P U=3.0C ST D TAY=MAX 12T OUT GF P U=0.3C GF D LAY=MAX 12T OUT INST=8X 2-1/2" 5/4/0—^. 2' 511 BUSWAY LC 100/•* 3 PH, 4W S -W/23 BUSWAY LD 100/" 3 PH, 4W W-1/23 REVIEWED FOH UNFPA OC NECTH NOV 07 2011 ity fo Tukwila LEGEND: GENERAL NOTES: 1. REFER TO SUBSTATION BOOK (3 -RING BINDER) ® PRIME POWER MAINTENANCE OFFICE, BLDG. 9-51.1 FOR UPDATED SETTING OF BREAKERS. MEL NELSON, PRIME POWER ELECTRICIAN, PHONE (206) 544-6937, IS THE CUSTODIAN OF THE BOOK. REFERENCE DRAWINGS: 1 > 9-101-E4S73 12 > 109-1018-2001-E4A 1 3 > 109-1018-2001-E4B CONSTRUCTION NOTES: REPLACE TRIP UNIT ON EXISTING MICROVERSATRIP BREAKER WITH NEW UNIT CAPABLE OF 300A TRIP SETTING. ADJUST SETTINGS AS INDICATED. RECEIVED CITY OF TUKWIL.A 12517 PERMIT CENTER C�1 5YIA A ADC THERMOPLATICS PIP 003205-01 6Y DLR GROUP APPROVED DATE SYM REVISION BY APPROVED DATE 090 06.28.17 ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED DRAWN PRS 3/31/04 CHECKED SUBTITLE ONE LINE DIAGRAM - SUBSTATION 74 CURRENT REV4510N 003205-01 SYMBOL A mm 06.28.17 APPROVED BY DEPT. DATE 1N0N1EN CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER ADC THERMOPLASTICS AFP BUILDING 09-101 DEV. CENTER, WA SHEET ES74 708 90. COMP N0. DWD N0. 09-101-ES74 METERS 733 BUI L, 4 DI V I 74F5 METERS AMMETER & SW TRANSFORMER 73F3 74F4 TRANSFORMER FDR FDR FDR FDR 7 1 1 7 11E MAIN MAIN 73F4 74F3 73F1 73F5 73F6 74F2 74F1 C�1 5YIA A ADC THERMOPLATICS PIP 003205-01 6Y DLR GROUP APPROVED DATE SYM REVISION BY APPROVED DATE 090 06.28.17 ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED DRAWN PRS 3/31/04 CHECKED SUBTITLE ONE LINE DIAGRAM - SUBSTATION 74 CURRENT REV4510N 003205-01 SYMBOL A mm 06.28.17 APPROVED BY DEPT. DATE 1N0N1EN CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER ADC THERMOPLASTICS AFP BUILDING 09-101 DEV. CENTER, WA SHEET ES74 708 90. COMP N0. DWD N0. 09-101-ES74 w 32a 1/\ cik2c //1 I 7 1 r1 11 r1 LJ {m 3 LASER ROOM 111V21 I r� 32a u _ 4L JI o /y\ 4 2a T-11 320 11— ' - tV ;un L --- u SEE SHEET 1E461V T22 -5/32a 411111111 PARTIAL LIGHTING PLAN SCALE: 1/8" = 1'-0" 1E42,3,5 6 E556 n R ui II n R 20A.. 6 LASER ROOM 111V21 9 LJ r1 L, u —9 L� I�1 LJ PARTIAL 120V/208Y POWER PLAN SCALE: 1/8" = 1.-0" 1E92,3,56 Q 3/ 30/NF �I-1/4c L4 I H� r1 LASER ROOM 3/4. nx r - I I LJ I � LJ ii 60A/NF RE SNF IJ L LEGEND UL -924 RELAY DEVICE, WATTSTOPPER ELCU-200 OR EQUAL ® SAFELY LATCH, EUCHNER MGB OR EQUAL DS DOOR POSITION SWITCH, PILZ PSENmag OR EQUAL GENERAL NOTES 1. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED 3. THE FOLLOWING COLOR CODING TO CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600—VOLTS OR LESS JKL 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAY. 6. FEEDERS TO PANESLA ND BUSWAYS SHOWN ON SHEETS E2 AND E3 7. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION 8. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB �.y g REFERENCE DRAWINGS Ef i i -)f f SEE DWG. #09-101-E605 FOR FIXTURE SCHEDULE NCE WITH F � - NEC 1 CONSTRUCTION NOTES 1-1_)17 2017 of Tukwila Nd DIVISION_ 1-1/44 iL hGG �.o I II LJI I I J L 11V22 u 11 �J F-� 1 TOI S18RTA1NIN 74 L 9C(2)3I75GNTN,RG 0(? 4--I m o II RG SCALE: PARTI 127.7V 48 Yff Iidr = 11 • 1O4235560 PROVIDE FINAL CONNECTION TO CORIOUS ELECTRICAL CABINET. COORDINATE ALL CONNECTION REQUIREMENTS WITH CORIOUS PRIOR TO INSTALLATION. PROVIDE CONNECTION TO OVERHEAD SECTIONAL DOOR MOTOR. CONFIRM FINAL REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. FIELD COORDINATE EXACT DISCONNECT LOCATION TO ENSURE THAT DISCONNECT IS ACCESSIBLE. PROVIDE CEILING MOUNTED RECEPTACLE FOR FUTURE OLT. PROVIDE CEILING MOUTNED RECEPTACLE FOR OWNER PROVIDED CAMERAS. PLATFORMS FOR OPERATOR ROOM AND MACHINE ROOM WILL BE +28' AFF. ALL HEIGHTS FOR WALL MOUNTED DEVICES SHALL BE ADJUSTED ACCORDINGLY. MOUNT IN -USE UGHT ABOVE DOOR ON EXTERIOR OF ENCLOSURE. PROVIDE EXTERNAL RELAY AND CONTROL WIRING BACK TO CORIOLIS CONTROLLER. COORDINATE FINAL CONNECTION REQUIREMENTS WITH CORIOUS PRIOR TO INSTALLATION. PROVIDE UL -924 DEVICE TO ALLOW CONTROL OF EMERGENCY FIXTURES WITH NORMAL FIXTURES. PROVIDE SAFETY LATCH ON CONTROL ROOM DOOR AND ASSOCIATED LOW VOLTAGE WIRING. CONFIRM FINAL CONNECTION REQUIREMENTS WITH OWNER PRIOR TO INSTALLATION. PROVIDE DOOR POSMON SWRCH AND ASSOCIATED LOW VOLTAGE WIRING BACK TO CORIOLIS CONTROLLER. COORDINATE FINAL CONNECTION REQUIREMENTS WITH CORIOLIS PRIOR IkENCEIVED D CITY OF TUKWILA a . � 1 7 2317 �DLR Group 2ERMIT CENTER ISSUE FOR CONSTRUCTION 06.28.17 SYM REVISION eT .47960 0 DA 5YM REVISION APPROVED DATE ORIG ADC THERMOPLASTICS AFP DD3205-1 DLR GROUP DMG 06.28.17 cciL_AirdsEzivc ACCEPTABILITY 1HIS DESIGN ANO/0R SPECIFICATION IS APPROVE) APPROVED BY DEPT. DATE DRAWN D. GIAMAUS CHECKED 11NGINEEH ECRED 5/12/17 SUBTITLE ENLARGED PLANS CLRRENT RE05044 DD3205-1 `0RIGd'E 06.28.17 APPROVED APPROVED FI 9CTOICAI 44.49990 ADC THERMOPLASTICS AFP BUILDING 09-101 1101 994,1995 W SHEET E556 J08 N0. D33205-1 CONP N0. DWG N0. 110-1l11-F55R H n 4I / H 9 ff 9 P n n I I LJ I I r—I LI I I / 1:>°)r7 I I L / / LASER ROOM 111V21 I \ n 11 LJ u ,11111111 PARTIAL LOW VOLTAGE PLAN SCALE: 1/8" = 1'-0" (71 PLATFORM PT1V211 PLATFORM I PT1V211 1 1 PLATFORM I PT1V211 AHU n 1 -1 PLATFORM PT1V211 4 2 r-- \ DNc INIIIIIII 111111 DN II#IIIIIIIIIIIIIIIIIII J L PARTIAL PLATFORM 1 20V/208Y PLAN SCALE: 1/8" = 1'-0" EEE57 30/IF F 1HP PLATFORM I PT1V21 I PLATFORM I PT1V21 I 1 30/NF 30/NF 10 rCo 1HP EF -1 PLATFORM I PT1V211 30/NF T VIEWED i -OR MPLIANCE WITH FPA 70 - NEC 07 20117 AHU-1 30 PLATFORM I PT1V21 City of Tukwila gil_piNG DIVISION 4 \ DN -11111111 IIIIII J L PARTIPLA 0 SCALE: 1/8 4: hi A Ir 1'1 SYM ORIG REVISION ADC THERMOPLASTICS AFP 033205-1 BY DLR GROUP APPROVED DATE SYM REVISION BY APPROVED DATE DMG 06.16.17 BOE/AW ACCEPTABILITY 11115 DESIGN AND/0R SPECIFIG00N IS APPROVED APPROVED BY DEPT. DATE DRAWN DMO S NGINEGH CHECKED APPROVED APPROVED 5 12/17 SUBTEE E557 LEGEND GENERAL NOTES 1. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED 3. THE FOLLOWING COLOR CODING TO CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS OR LESS JKL 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6. FEEDERS TO PANESLA ND BUSWAYS SHOWN ON SHEETS E2 AND E3 7. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION 8. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB 9. ANY PENETRATIONS OF THE LASER ENCLOSURE FOR DATA CABLING THAT IS NOT IN CONDUIT SHALL UTILIZE STI EZ -PATH SMOKE AND ACOUSTICAL PATHWAY TO ENSURE THE PATHWAY IS SEALED FOR LIGHT PENETRATION. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CONNECTION TO OVERHEAD DOOR MOTOR. CONFIRM FINAL REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. MOUNT DISCONNECT ON UNISTRUT ABOVE ENCLOSURE. FIELD COORDINATE EXACT DISCONNECT LOCAITON TO ENSURE THAT DISCONNECT IS ACCESSIBLE. ENSURE CONDUIT ROUTING 15 INSTALLED BEHIND RAILING GUARD AND CLEAR OF PATHWAY. PROVIDE CONNECTION TO MECHANICAL HVAC UNIT. CONFIRM FINAL REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. FIELD COORDINATE EXACT DISCONNECT LOCATION TO ENSURE THAT DISCONNECT IS ACCESSIBLE AND RAS CODE REQUIRED CLEARANCE. ENSURE CONDUIT ROUTING IS INSTALLED CLEAR OF PATHWAY. PROVIDE EMPTY J -BOX WITH GROMET COVERPLATE FOR FUTURE DATA WIRING. PROVIDE 1-1/4' CONDUIT BETWEEN J -BOXES BACK TgogRQL E V EE D CITY OF TUKWILA LDLRGroPpRMIT CENTER u Md*CI,M tn.ineetrag monks fl!&= ISSUE FOR CONSTRUCTION 06.28.17 ENLARGED PLANS CURRENT REVISION D33205-1 s'uwORIG DATE 06.16.17 TITLE ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 DEV. CENTER, WA SHEET E557 JOB N0. D33205-1 COMP N0. DWG NO. 09-101-E557 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING FIXTURE VOLTAGE LAMPS BALLAST MANUFACTURERS CATALOG REMARKS SERIES NUMBER SYMBOL TYPE QTY, F1 COMBINAr1ON DIRECT/INDIRECT LUMINAIRE; 75% UPLT/25% DNLT BAKED WHITE ENAMEL FINISH, 4' LENGTH DOUBLE DIFFUSING OPTICAL SYSTEM, MICRO PRISM DIFFUSER CENTER OPTICAL CHANNEL, PROGRAMMED START ELECTRONIC BALLAST; <10% THD UL LISTED, UNIVERSAL VOLTAGE BALLAST. SURFACE MTD W/MTG HARDWARE AS INDICATED ON DWGS. S 1'X4' 120/277 F54 T85HO 35 1 ELECTRONIC FINELITE, 5-15-4 -1TSH0 SC -120/277 -SM w® SAME AS TYPE "SF1A" EXCEPT 8' LONG. S 1'X8' 120/277 F54 835 2 ELECTRONIC FINELITE, 5-15-8-1T5H0-SC-120/277-SM A® SAME AS TYPE "SF1A" EXCEPT 12' LONG. S 1'X12' 120/277 T5345 5 3 ELECTRONIC FSIN SITE 2'-1T5H0-SC-120/277-SM Arm RECESSED DIRECT/INDIRECT 2'X4' FIXTURE; LAMP COMPARTMENT ACRYLIC PRISMATIC DIFFUSER WITH LIGHT DIFFUSING FILM; PROGRAMMED START ELECTRONIC BALLAST; <10% THD UL USTED UNIVERSAL VOLTAGE BALLAST P 2'X4' 120/277 F54 T835 2 ELECTRONIC LITHONIA 2RT5-28T5-120/277-GEB95-LPM835P litr zit PENDANT DIRECT 1'X8' FIXTURE; HIGH -GLOSS BAKED WHITE ENAMEL FINISH HEAVY DUTY 20 -GAUGE CHANNEL; WHITE STRAIGHT BLADE LOUVER; PROGRAMMED START ELECTRONIC BALLAST; <10% THD UL LISTED UNIVERSAL VOLTAGE BALLAST P 1'X8' 120/277 F54 T5 835 2 ELECTRONIC LITHONIA -54T5H0 SBL 120/277-GE810PS ® PENDANT DIRECT 1'X4' FIXTURE; MATTE BLACK ENAMEL FINISH; 22 -GAUGE CHANNEL; 0-10V DIMMING DRIVER; DLC LISTING P 1'X4' 120/277 35K LED 0-10V DRIVER GE LDS -C4 A 0 65 WO 8-35-VQ-SM-BLCK Ani, WALL MOUNTED "LASER IN USE" LIGHT, ALUMINUM FRAME, BACKLIT ACRYLIC FACE WALL 120/277 LED ELECTRONIC SIGNAL -TECH 38638 © X1 THERMOPLASTIC EXIT SIGN, BLACK FINISH WALL 120/277 LED ELECTRONIC XITRUNIBVEXP-LB-BL ISSUE FOR CONSTRUCTION 06.28.17 L DLR Group SYM PENSION RECORD DRAWING DCA -9-05013 A ADC THERMOPLASTICS AFP D33205-01 BY DLR GROUP DLR GROUP APPROVED DATE 00M BY APPROVED DATE LM/Ls 090 12.19.08 06.28.17 16 tell D OOUP MEM AF 'LBW cc/4 ACCEPTABILITY This DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE D REVIEWED .Ruin COMPLIANCE ECITH li NF NOV 07 2017 City of Tukwila ILDING DIVISION RECEIVED CITY OF TUKWILA . PERMIT CENTER CHECKED DATE 11.21.05 12.06.05 SUBTITLE LIGHT FIXTURE SCHEDULE CURRENT REVISION D33205-01 SYMBOL A DATE 06.28.17 APPROVED APPROVED TIME ADC THERMOPLASTICS AFP ELECTRICAL MASTER BUILDING 09-101 DEV. CENTER, WA SHEET E605 JOB NO.DCA-9-05013 COMP N0. DWG NO. 09-101 -E605 PY PERMIT REVIEW/ROUTING NG SLIP PERMIT NUMBER: EL17-0870 DATE: 11/1/17 PROJECT NAME: BOEING #9-101 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Aux - Building Division Public Works Fire Prevention Structural Planning Division ri ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 11/02/17 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWERcS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/30/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERcS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SEQUOYAH ELECTRIC LLC ct) Home Espanol Contact Safety & Health Claims & Insurance Ch, Washington State Department of Labor & Industries Search L&I .AZ'Index Help Page 1 of 2 L &1 Workplace Rights Trades & Licensing SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Trocano, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC WA UBI No. 602 252 591 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County Business type Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........._....._............................................. Meets current requirements. License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003— 01/30/2019 Designated administrator NICHOLS, DAVID E License type Master Electrician Bond ..... _...... HARTFORD CAS INS CO Bond account no. 52BSBAB5541 Active. Meets current requirements. License no. NICHODE97406 $4,000.00 Received by L&I Effective date 01/29/2003 01/29/2003 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591 &LIC=SEQUOEL977S9&SAW= 11/9/2017 SEQUOYAH ELECTRIC LLC Savings No savings accounts during the previous 6 10.period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 061,981-00 _.......... ................... Doing business as SEQUOYAH ELECTRIC LLC Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / MELVINA RAMSDELL (360)902-4814 - Email: RAMM235@lni.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 01/13/2016 Inspection no. 317937437 Location 501 North Newport Ave Newport, WA 99156 Inspection results date 03/14/2012 Inspection no. 315581264 Location 3003 W Casino Rd Everett, WA 98203 Violations Violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591 &LIC=SEQUOEL977S9&SAW= 11/9/2017