Permit EL17-0934 - CHICK-FIL-A - NEW RESTAURANT
CHICK-FIL-A 17333 SOUTHCENTER PKWY ELI 7-0934 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 2623049066 17333 SOUTHCENTER PKWY Project Name: CHICK-FIL-A Permit Number: Issue Date: Permit Expires On: EL17-0934 7/31/2018 1/27/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KOMETANI MICHAEL 1823 HALEKOA DR , HONOLULU, CA, 96821 CARLOS ARIAS PO BOX 270571, SAN DIEGO, CA, 92198 SOUTHGATE ELECTRIC INC 23444 30TH AVE S #101, KENT, WA, 98032-2807 SOUTHEI366P1 Phone: (951) 970-9138 Phone: (206) 878-2866 Expiration Date: 8/30/2019 DESCRIPTION OF WORK: NEW COMMERCIAL FAST FOOD RESTAURANT WITH DRIVE-THRU Valuation of single family: $0.00 Valuation of mf/comm: $125,000.00 Type of Work: NEW Fees Collected: $2,596.34 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating const rues• �� •r the performance of work. I am authorized to sign and obtain this development permit and agree t• onditions attached to this permit. Signature: Date: 7 Print Name: c//2/ -S //9C 4403 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWIL Community Developmen artment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Perm 'to. & C-,1- &q i Project No. Date Application Accepted: J ' -) � "I % Date Application Expires: '[ (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17333 Southcenter Parkway Tenant Name: Chick-fil-A, Inc. PROPERTY OWNER Name: Carlos Arais Name: Michael Kometani Address: PO Box 270571 Address: 1823 Halekoa Drive City: San Diego State: CA City: Honolulu State: HI Zip: 96821 CONTACT PERSON — person receiving all project communication Name: Carlos Arais Address: PO Box 270571 City: San Diego State: CA Zip: 92198 Phone: (951) 970-9138 Fax: Email: carias@4gdev.com State: King Co Assessor's Tax No.: Suite Number: Floor: 1 New Tenant: ® Yes ❑ .. No 2623049066 ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 125,000 Scope of Work (please provide detailed information): New commercial restaurant with drive-thru Will service be altered? ® Yes ❑ No Adding more than 50 amps? lia Yes ❑ No Type of Use: To service a 1200 amp service panel Type of work: 0 New ❑ Addition ❑ Service Change 0 Remodel 0 Tenant Improvement 0 Low Voltage 0 Generator ❑ Fire Alann ❑ Telecommunication ❑ Temporary Service Property Served by: 2 Puget Sound Energy 0 Seattle City Light W:\Pcmtit Center \Applications-Handouts\Permit Applications\PDF's\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page I of 2 c RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, fumace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ' ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: ��^LC Date: / / /2424 7 Print Name: OAILL-OS Al2- ` S Day Telephone: (?1-1) 7V 9/38 Mailing Address: Po SOX .27O S 7 W\Permit CenteMWpplications-Hnndouts\Permit Applications\PDFs\Electrical Permit Application Revised 1.1.17.docx Revised: January 2017 bh S' A' Di 56- o City State ?'2/9e Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,085.02 E117-0934 Address: 17333 SOUTHCENTER PKWY Apn: 2623049066 $2,085.02 ELECTRICAL $1,985.73 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,985.73 TECHNOLOGY FEE $99.29 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14514 R000.322.900.04.00 0.00 $99.29 $2,085.02 Date Paid: Thursday, May 17, 2018 Paid By: CHICK-FIL-A INC Pay Method: CHECK 1142024 Printed: Thursday, May 17, 2018 11:52 AM 1 of 1 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $5,896.78 D17-0313 Address: 17333 SOUTHCENTER PKWY Apn: 2623049066 $4,889.07 Credit Card Fee $142.40 Credit Card Fee R000.369.908.00.00 I 0.00 $142.40 DEVELOPMENT $4,496.67 PLAN CHECK FEE R000.345.830.00.00 I 0.00 $4,496.67 PUBLIC WORKS $250.00 BASE APPLICATION FEE R000.322.100.00.00 I 0.00 $250.00 EL17-0934 Address: 17333 SOUTHCENTER PKWY Apn: 2623049066 $511.32 Credit Card Fee $14.89 Credit Card Fee R000.369.908.00.00 0.00 $14.89 ELECTRICAL $496.43 PLAN CHECK FEE R000.345.832.00.00 0.00 $496.43 M17-0176 Address: 17333 SOUTHCENTER PKWY Apn: 2623049066 $341.93 Credit Card Fee $9.96 Credit Card Fee 1 R000.369.908.00.00 0.00 $9.96 MECHANICAL $331.97 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 $331.97 PG17-0149 Address: 17333 SOUTHCENTER PKWY Apn: 2623049066 $154.46 Credit Card Fee $4.50 Credit Card Fee I R000.369.908.00.00 0.00 I $4.50 GAS t $24.86 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 PLUMBING $125.10 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R12841 0.00 $125.10 $5,896.78 Date Paid: Tuesday, November 21, 2017 Paid By: CARLOS ARIAS Pay Method: CREDIT CARD 05596D Printed: Tuesday, November 21, 2017 11:37 AM 1 of 1 SYSTEMS INSPECTION RECORD INSPECTION NO. Retain a copy with permit 6,7_0?3ti CITY OF TUKWILA BUILDING DIVISION NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 367 Permit Inspection Request Line (206) 438-9350 Project: �✓ 1164(6.—Type of Inspection: Af Address. Date Called: Special Instructions: A Date Wanted: 22— a m P- Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: ` 0 l 4. Inspector: Date: 0 REINSPECTIOIj1 FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. /1 - INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 /� Project: . a_ ht. -A- Type of Inspection: —* Address/7333_5.c . P y Date Called: Special Instructions: Date Wanted: I �� a l Requester: td c (50 6 eA40 ca.)) Phone No: 2,04, 224„ 65.37 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4,t 5� 6Dikk,(C419/\/ Atl- (2a v R,t I5 pi F04o PP 6 td c (50 6 eA40 ca.)) to P5 f C1-0 PP. it Inspector: !J ;j�4 Q l Date: t 1 � REINSPECTION FEE REQUIRED. Prior to next inspection. ee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INS'ECTION NO. INSPECTION RECORD Retain a copy with permiti( t47-o7i MIT .0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ,�l , / 1. Type of Inspection: r Address:�n��� `e` .. pt l.��. Date Called:LL//,J Special Instructions: Date Wanted: /72; / 7 1 Wim. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: i� 664A A/45 9CCA--r" 415 -4( -- inspector: \ /� �r� `Tl Date: 121z4 (1, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: /IHC4 6L- 4- Type of Inspection:©. r�t{ /4/ Address: 17333 csm pit Date Called: Special Instructions: Date Wanted:a:m; Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 10\- A-L�j 041 Inspector: Vlh:6\iijo\ Date: /212.411g Z 1g REINSPECTION PEE REQUIRED. Prior to next inspection. fe must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPE ION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Z44-tcif._,- A- Tf Ip�peJcti[n: /% t Address:%', _, , pi Dat Called: Special Instructions: Date Wanted: �ff a.m., Requester: Phone No: 206224 J_ / Approved per applicable codes. Corrections required prior to approval. COMMENTS: 174 11V -- Pm -1 0‘4-619- au4A161 5ork\ita -61)61k5 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. r't� INSPECTION RECORD Retain a copy with permit EL(7-qgt j PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � tc_ r; r Type of Insection: Add ess:Date (7 Z 3 3 S c_]-(2_ /14 (^y Called: tees^ Ci ✓`640 riI Special Instructions: J o -✓7,-h 9c,.K ti. j� �/ 24,6) isl Cif 21i6,ro NM Date Wanted: a.m. p.m. Requester: Phone No: / Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ) L9 od el-- Poor`c5- Co t --JL., l ) tr-) S-ert) IX L. (r) i".1. (1 v 1(59- GA, yrJ 1 h 6/ 1A' -/-(i 2. Ori ,c. t-'roc/r1, G�i''N -A+Lr 410 1" e-hci ID c., et.rit Inspector: Date) I ).24// REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPE ION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: (Ala_ 6, k Type of Inspection: U Address: 7 �� / Date Called: Special Instructions: Date Wanted: V l (o 7 (a rr� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pe 0 LA\ Cab013 jvJ. & ni-uk) Nva Inspector: &kik Date: t t Olt REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: ( f ,.' r / f'" Type of Inspection: it �' Address: 733i SC''' PI^ Date Called: Special Instructions: Date Wanted: . 0ill pi: Requester: Phone No: 2.6 zo 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: r i 5zire Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPE TION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 4 11i, &) 1(-- — (ii — Type of Inspection: d(oiI Address: �2? /GJa>S..c t� Date Called: Special Instr ctions: Date Wanted: pm. Requester: Phone No: (6; 873 ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: ' ' a Car i Inspector: Date: 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Retain a copy with permit INSPECTION RECORD —a73 INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: 4+104....k.,.... Ac. Type of Inspection: ddress:1 Address:/7333 Date Called: Special Inst uctions: Date Wanted: /a,m' Requester: Phone No: Approved per applicable codes. I Corrections required prior to approval. COMMENTS: OLY\. tc*i) 0,F6A stir 1-44-r) Inspector: 0/02.REINSPECTION EE REQUIRED. Prior to next inspection. fe must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Wi r"?✓ P RMI T N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: /4V k Type of Inspection: u Address: (j / 7,133 SC- Date Called: Special Ins ructions: Date Wanted: al. Requester:/ft ...,...i-- ‘,LA' Phone No: 2a, 2, 6C37 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 04 eo bd (5,(: Ucto--f5 ft-dP �1flnl��(ren� Inspector: (-166j4161)\ Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit `. O3 P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 - Project: Type f nspection: Address:rr /7333 �.J•C— Date Cal ed: Special Instructions: Date Wanted: y/i0( a.m pma Requester: �) -i i 01-7 Phone No: 70(p F 8713 Approved per applicable codes. Corrections required prior to approval. COMMENTS: YR- odi/D 01 • kirrkoi -Go7P(1-41- 11r2v Jh � (51-07��5 hia4tei roo i t ^fv1 (AfC3 Inspector:/ 671/4 Date: 07/01/4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Cv7oJ3 PMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: yr c. - lir - Type of Inspection: ill Address:P(. )� L:- Date Called: Special InstrUctiorfs: U-(6\ Date Wanted: a.m. oy Requester: Phone No: 24.237X za& 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: PP ( kfr67\tJAirli-- Inspector: Date: 090i `1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection, 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director May 21, 2018 Carlos Arias 4G Development and Consulting, Inc. PO Box 270571 San Diego, CA 92198 RE: Request for Extension #1 Permit Number EL17-0934 Dear Mr. Arias, This letter is in response to your written request for an extension to Permit EL17-0934. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 21, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, achelle Ripley Permit Technician File: Permit No. EL17-0934 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Rachelle Ripley From: Carlos Arias <carias@4gdev.com> Sent: Thursday, May 10, 2018 9:55 AM To: Rachelle Ripley Subject: Southcenter // Permit Extension Good morning Rachelle, As discussed, can you please help issue an extension for all of the permits listed below. We do not have a GC yet. They should be awarded the job by the end of this week. Please advise. Mechanical: M17-0176 Plumbing: PG17-0149 Electrical: EL17-0934 Development: # D17-0313 Demo Permit: # D17-0315 Carlos Arias — Project Engineer 4G DEVELOPMENT AND CONSULTING, INC. P.O. Box 270571, San Diego, CA 92198 P (951) 970-9138 / F (866) 311-3658 Request for Extension # Current Expiration Date: Extension Request: Approved for [ / or days Denied (provide explanation) 1 i Signature/Initials l4/ 4/2/2018 City of Tukwila Department of Community Development CARLOS ARIAS PO BOX 270571 SAN DIEGO, CA 92198 RE: Permit Application No. EL17-0934 CHICK-FIL-A 17333 SOUTHCENTER PKWY Dear CARLOS ARIAS, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 11/21/2017, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 5/21/2018. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, chelle Ripley Permit Technician File No: EL17-0934 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 OERM1T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0934 PROJECT NAME: CHICK-FIL-A DATE: 05/17/18 SITE ADDRESS: 17333 SOUTHCENTER PKWY Original Plan Submittal X Revision # 1 before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural El Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/17/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/14/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED:. Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 cERMIT COORD COPY C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL 17-0934 DATE: 11/21/17 PROJECT NAME: CHICK-FIL-A SITE ADDRESS: 17333 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Nli Pe 11' j Building Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/23/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/21/17 Approved Corrections Required ❑ Approved with Conditions nDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 C.) PROJECT NAME: C,INA �`(-- PERMIT NO: SITE ADDRESS: 11333 S0 IANto ' 'kill ORIGINAL ISSUE DATE: I REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS i 5-'11-19 TY Summary of Revision: lacgr4-C S Es. i off- I`c1lli- 4.6 iv ca ro peeii lowyNotiekn Received by:r0----- = REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 5-14-18 Date: Plan Check/Permit Number: ELI7-0934 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # 1 after Permit is Issued(Permit has not yet been issued) ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Chick-fil-A Project Address: Contact Person: 17333 Southcenter Pkwy, Tukwila WA 98188 Carlos Arias Phone Number: 951-970-9138 Summary of Revision: Southeast lot Tight located outside of the property line has been relocated inside our property line. Update to MDP location. RECEIVED CITY OF TUKWILA MAY 1 4 2018 PERMIT CENTER Sheet Number(s): A-100, ES -1, ES -2, E-221 "Cloud" or highlight all areas of revision including date oIfrevision r?At,i- W� Received at the City of Tukwila Permit Center by: [� Entered in TRAKiT on W:\Permit Center\Templates\Fornss\Revision Submittal Form.doc Revised August 2015 SOUTHGATE ELECTRIC INC Home Espanol Contact Safety & Health Washington State Department of Labor & Industries Claims & Insurance Search L&I A -Z Index Hell? Workplace Rights SOUTHGATE ELECTRIC INC Owner or tradesperson Principals PSACHOS, CHRIS, PRESIDENT Brennan, Pat J, VICE PRESIDENT Psachos, Debbie K, SECRETARY PSACHOS, CHRIS, AGENT PSACHOS, BARBARA, SECRETARY (End: 08/03/2001) STEIGERS, HERBERT C (End: 09/30/2011) Doing business as SOUTHGATE ELECTRIC INC WA UBI No. 578 089 488 23444 30TH AVE S STE 101 KENT, WA 98032 206-878-2866 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SOUTHEI366P1 Effective — expiration 10/21/1964— 08/30/2019 Designated administrator BRENNAN, PATRICK JOSEPH License type Electrical Administrator Bond ............... CBIC Bond account no. 611625 Savings No savings accounts during the previous 6 year period. License Violations Active. Meets current requirements. License no. BRENNPJ066RC $4,000.00 Effective date 10/28/1978 Expiration date Until Canceled Page 1 of 3 My L&I Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578089488&LIC=SOUTHEI366P1&SAW= 7/31/2018 SOUTHGATE ELECTRIC INC Infraction no. EDORN00251 Issue date 03/20/2014 Violation city Kent Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EJONV02984 Issue date 04/30/2013 Violation city KENT Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EBJOR00314 Issue date 01/02/2013 Violation city Kent Type of violation ELECTRICAL CITATION Description Covering or concealing installations prior to inspection. Satisfied ..................... RCW/WAC 19.28.101 RCW Violation amount $4,000.00 Satisfied ........................ RCW/WAC 19.28.101 RCW Violation amount $250.00 Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Infraction no. EBJOR00313 Satisfied ............... d Issue date RC 01/02/2013 19.28.101 RCW Violation amount $1,000.00 Violation city Kent Type of violation ELECTRICAL CITATION Description Failing to obtain or post an electrical/telecommunications work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-900 (3)(6), effective after 12/30/2008 see WAC 296- 46B-901. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578089488&LIC=SOUTHEI366P1&SAW= 7/31/2018 3/9/2018 10:12:47 AM 3" 3'-0" 3" TYP. ti TOP VIEW OLYMPIA BIKE RACK MODEL: SKOLY, POWDER -COATED COLOR : BLACK C BIKE RACK DETAIL C N.T.S. ASITE PLAN 1" = 20'-0" SIDE VIEW 4 11 GRADE RE: CIVIL >p<1:7, •4 3E EXTERIOR GRADE AT BUILDING CURB 1 1/2" = 1'-0" 3 SOUTHCENTER PARKWAY 2 FILE COPY Permit No.E 1-1 - 311 Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or o t nance. Receipt of approved Field Co , is acknowledged: City of Tukwila BUILDING DIVISION SITE PLAN LEGEND PROPERTY LINE BUILDING LINE NEW 6" CURB & GUTTER NEW SIDEWALK EXISTING CURBS AND SIDEWALKS OUTDOOR SEATING PEDESTRIAN ACCESS 4" WIDE DIAGONAL SRIPPING PARKING LIGHT FIXTURE EASEMENT LINE VEHICLE (20'-0" LENGTH TYP.) L ' " L / • • //////////// Elea 0 A KEYNOTES- SITE PLAN 1. TRASH ENCLOSURE RE: SHEET A110 2. NOT USED 3. BIKE RACKS RE: DETAIL 4E/A-100 4. LANDSCAPE AREA RE: LANDSCAPE DRAWINGS 5. CONCRETE DRIVE AREA 6. CONCRETE SIDEWALK 7. ADA PATH OF TRAVEL 8. ADA SPACES, STRIPING, SIGNAGE AND RAMPS RE: CIVIL DRWINGS 9. DRIVE-THRU/PARKING STRIPING RE: CIVIL DRAWINGS 10. DRIVE-THRU MENU BOARDS BY SIGN COMPANY, FOOTING TO BE COORDINATED WITH GC 11. HEIGHT CLEARANCE ARM BY SIGN COMPANY, FOOTING TO BE COORDINATED WITH GC 12. DIRECTIONAL SIGN BY SIGN COMPANY, FOOTING TO BE COORDINATED WITH GC 13. FLAG POLE BY SIGN COMPANY, FOOTING TO BE COORDINATED WITH GC 14. GREASE INTERCEPTOR RE: PLUMBING 15. SITE LIGHTING RE: ELECTRICAL 16. EXISTING MONUMENT SIGN 17, EXISTING TRANSFORMER E D Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 s _ ®A ARCH ITECTS 195 South C Street; Suite 200 Tustin, CA, 92780 Phone 714.832.1834 SEAL 10830 REGISTERED ARCI-HTECT SITE DATA REVISIONS No changes shall be made to the scone of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1. ZONING CLASIFICATION 2. OCCUPANCY 3. CONSTRUCTION TYPE 4. FIRE SPRINKLERED 5. SITE AREA 6. BUILDING AREA 7. BUILDING HEIGHT 8. FAR (BUILDING AREA/PARCEL AREA) PARKING 1. PARKING REQUIRED STANDARD SPACES TOTAL SPACES 2. PARKING PROVIDED STANDARD SPACES COMPACT SPACES HANDICAP SPACES TOTAL SPACES 3. BICYCLE PARKING REQUIRED PROVIDED REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 21 2018 City of Tukwila BUILDING DIVISION 1 SEE BUILDING DATA ON SHEET -G011 SEE BUILDING DATA ON SHEET -G011 SEE BUILDING DATA ON SHEET -G011 YES 65,905 SQ. FT. (1.51 ACRES) SEE BUILDING DATA ON SHEET G-011 SEE BUILDING DATA ON SHEET G-011 0.08 1 PER 50 SQ.FT. OF NET AREA + 1/100 SQ.FT. EXTERIOR DINING AREA B 4,475 SQ.FT. / 50 SQ.FT. = 89.5 (90 SPACES) 0 SQ.FT / 100 SQ.FT. = 0 (0 SPACES) = 90 SPACES 93 00 03 96 1/50 PARKING SPACES = 2 8 REVISION NO. 111 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION 1 02-26-18 AGENCY REVISIONS RECEIVED CITY OF TUKWILA MAY 142018 PERMIT CENTER ARCHITECTS PROJECT # 16-105 PRINTED FOR CONSTRUCTION DOCUMENTS Cl) DATE I `Z DRAWN BY 11/13/17 SF 2 Information contained on this drawing and in all D digital tiles produced for above named project 0 may not be reproduced in any manner without Oexpress written or verbal consent from authorized project representatives. CI SHEET z0 SITE PLAN 0 ix SHEET NUMBER 1 A=100 KEY NOTES -ELECTRICAL SITE PLAN (APPLIES TO THE ELECTRICAL SITE PLAN ONLY) PRIMARY UNDERGROUND ELECTRICAL UTILITY LINES. REFER TO SHEET E -502 -FOR ADDITIONAL REQUIREMENTS. UTILITY TRANSFORMER AND SLAB BOX. THE ELECTRICAL CONTRACTOR SHALL PROVIDE: A. SECONDARY SERVICE LATERAL FROM POWER UTILITY COMPANY TRANSFORMER TO MAIN DISTRIBUTION PANEL 'MDP'. PROVIDE FOUR (4) 4"C.O., (SCH. 40 PVC CONDUIT) TO UTILITY SOURCE, AT MINIMUM 30" BELOW FINISHED GRADE AND IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS. CONDUCTORS SHALL BE INSTALLED AND CONNECTED BY POWER UTILITY COMPANY. COORDINATE ALL REQUIREMENTS WITH POWER UTILITY COMPANY) PRIOR TO BID. REFER TO SHEET E-502, "SINGLE -LINE DIAGRAM", AND, "ELECTRICAL SERVICE LATERAL CONDUIT DETAIL", ON SHEET E-001 FOR ADDITIONAL INFORMATION. B. CONCRETE SLAB BOX FOR UTILITY TRANSFORMER IN ACCORDANCE WITH POWER UTILITY COMPANY REQUIREMENTS. REFER TO SHEET. E-502 FOR ADDITIONAL REQUIREMENTS. 3. LOCATION OF TERMINATION OF SECONDARY SERVICE LATERAL AT PANEL 'MDP'. REFER TO "SINGLE -LINE DIAGRAM", SHEET E-502, FOR ADDITIONAL INFORMATION. 4. PROVIDE ONE (1) 4" SCH. 40 PVC CONDUIT FOR TELEPHONE/CATV/ISP SERVICE CONNECTION AND ONE (1) SPARE 4" SCH. 40 PVC CONDUIT. INSTALL CONDUITS MINIMUM 24" BELOW FINISHED GRADE, FOR SERVICE FROM COMMUNICATIONS UTILITY SOURCE(S) TO JUNCTION BOX(ES) WITHIN BUILDING. REFER TO SHEET E-221 FOR LOCATION OF TERMINATIONS. REFER TO "COMMUNICATIONS UTILITY SERVICE CONDUIT DETAIL", ON SHEET E-001, FOR ADDITIONAL INFORMATION. COORDINATE EXACT LOCATION OF UTILITY SOURCE(S) WITH COMMUNICATIONS UTILITIES. TERMINATE CONDUITS AT UTILITY SOURCE AS REQUIRED BY THE UTILITY COMPANIES. 5. LOCATION OF TRASH ENCLOSURE. REFER TO "REFUSE ENCLOSURE PLAN - ELECTRICAL", SHEET E-250 FOR ELECTRICAL REQUIREMENTS IN THIS AREA. 6. REFER TO SHEET E-004 FOR ELECTRICAL REQUIREMENTS AT MENU BOARD AND DRIVE-THROUGH CANOPY. CONNECTION OF EQUIPMENT GROUNDING CONDUCTOR SHALL BE MADE IN ACCORDANCE WITH 250.130 IN A METHOD SPECIFIED IN 250.8 OF THE NATIONAL ELECTRICAL CODE. BOND METAL PARTS OF THE SIGN TO THE GROUNDING CONDUCTOR OF THE BRANCH CIRCUIT IN ACCORDANCE WITH 250.180 OF THE NATIONAL ELECTRICAL CODE. FEEDER "PF" REFER TO SINGLE LINE DIAGRAM, SHEET E-502 UTILITY TRANSFORMER\ 2 A2B/ AND SLAB BOX. REFER TO SINGLE LINE DIAGRAM, SHEET E-502 NOTE: ALL FEEDER CONDUITS TO AND FROM MAIN DISTRIBUTION PANEL "MDP" SHALL BE RUN UNDERGROUND, BELOW GRADE, OR OTHERWISE CONCEALED. NO EXPOSED CONDUITS SHALL BE VISIBLE ON THE EXTERIOR OF THE BUILDING. MAIN DISTRIBUTION PANEL "MDP" SEE SINGLE LINE DIAGRAM, E-502 FLAG POLE 2#10,1 #10GND: 3/4"C. A\/ FEEDER "SF" REFER TO SINGLE LINE DIAGRAM SHEET E-502 Chick-fiI-A 5200 Buffington Road Atlanta, Georgia 30349-2998 PROJECT MEP, INC, CONSULTING ENGINEERS Mechanical - Electrical - Plumbing 1221 E. Dyer Rd. Suite 260 Santa Ana, CA 92705-5654 (949) 428-8800 6 )MENU BOARD 7. REFER TO SHEETS E-901 AND E-902 FOR ELECTRICAL SPECIFICATIONS PERTAINING TO ELECTRICAL WORK DESCRIBE ON THIS SHEET. 8. REFER TO SHEET E-221 FOR EXTERIOR LIGHTING IN PATIO DINING AREA. 9• PROVIDE CONDUIT TO JUNCTION BOX IN OFFICE FOR POLE MOUNTED SECURITY CAMERA. REFER TO. SHEET E-302 FOR LOCATION. OF JUNCTION BOX IN OFFICE. COORDINATE EXACT CAMERA LOCATION WITH CHICK-FIL-A SECURITY SYSTEM REPRESENTATIVE PRIOR TO ROUGH -IN. 10. ROUTE SITE LIGHTING CIRCUITS THROUGH THE "T-500" LIGHTING CONTROL PANEL (TYPICAL). REFER TO LIGHTING CONTROL DIAGRAM ON SHEET E-002, AND PANEL SCHEDULES ON SHEET E-501. 11 COORDINATE LOCATIONS OF ALL SIGNS WITH CHICK-FIL-A REPRESENTATIVE PRIOR TO BID AND PRIOR TO CONDUIT INSTALLATION. 12. PROVIDE GFCI TYPE RECEPTACLE WITH 'IN -USE' STYLE, EXTRA DUTY RATED, WEATHERPROOF COVER, MOUNTED ON MAIN SIGN SUPPORT +14" AFG. THIS RECEPTACLE SHALL NOT BE SWITCHED. (BYPASS THE CONTACTOR AND SIGN'S DISCONNECT SWITCH.) 13. PROVIDE WEATHERPROOF 20A SPST TOGGLE SWITCH 18" AFG AND CONNECTION TO MAINTENANCE DISCONNECT SWITCH FOR MAIN I.D. SIGN. 14. PROVIDE WEATHERPROOF 20A SPST TOGGLE SWITCH 18" AFG AND CONNECTION TO MAINTENANCE DISCONNECT SWITCH FOR DIRECTIONAL. SIGN. CONNECTION OF EQUIPMENT GROUNDING CONDUCTOR SHALL BE MADE IN ACCORDANCE WITH 250.130 IN A METHOD SPECIFIED IN 250.8 OF THE NATIONAL ELECTRICAL CODE. BOND METAL PARTS OF THE SIGN TO THE GROUNDING CONDUCTOR OF THE BRANCH CIRCUIT IN ACCORDANCE WITH 250.90 AND 250.8 OF THE NATIONAL ELECTRICAL CODE. 15. REFER TO BUILDING DRAWING E-221 & E-302 FOR LAYOUT OF THE SERVICE AREA. COORDINATE LOCATIONS OF ALL ITEMS AT THE SERVICE YARD AREA PRIOR TO ROUGH -IN OF ANY ITEMS INSTALLED ON OR NEAR THE SERVICE YARD. COORDINATE EXACT LOCATIONS OF SECURITY SYSTEM EQUIPMENT WITH CHICK-FIL-A SECURITY SYSTEM REPRESENTATIVE PRIOR TO ROUGH -IN. 16. PROVIDE #10 CONDUCTORS, ENTIRE CIRCUIT LENGTH. 17. MOUNT AND AIM FLAG POLE LUMINAIRE FOR 360 -DEGREE ILLUMINATION OF FLAGS. AIM AT NIGHT. REFER TO DETAIL #6, E-001 FOR ADDITIONAL REQUIREMENTS. 18. COORDINATE FINAL LOCATION WITH FIRE SPRINKLER DOUBLE. CHECK VALUE ASSEMBLY AND CIVIL DRAWINGS. 19. 5#10,1#10GND.-1"C. (MENUBOARD). 20. C-38 TO THREE POSITION, SINGLE POLE, DOUBLE THROW SWITCHES LOCATED AT INTERIOR DRIVE THROUGH ORDERING POINT OF SALES STATION. 21. (2) 1" CONDUITS TO FIRE ALARM CONTROL PANEL. POST INDICATOR VALVE LOCATION (BY DEVELOPER) MAIN TELEPHONE BACKBOARD "MTBB" SEE SHEET '1 . I REFUSE ii ENCLOSURE REFER TO DETAIL #2, SHEET E-250 —� P12 LO IRC 121 SFATS V,/ ,' PLAYGROUND GSF4 IJi .r. D C-23(\10 )c_1_6) f 2#10,1 #10GND.-3/4"C. MONUMENT SIGN /T-2,7 DIRECTIONAL SIGN DIRECTIONAL SIGN C EXISTING PARKING J LL co oo r cci co11�a = as :::11:::: M N M 3 0 WO 11' Tukwila, WA)/04094_Tukwila, WA_ELE.rvt GENERAL ELECTRICAL SITE PLAN NOTES (APPLIES TO THE ELECTRICAL SITE PLAN ONLY) VERIFY WITH LOCAL AUTHORITIES AND UTILITIES THAT OWNER'S SIGNS, POLES, AND THEIR APPURTENANCES ARE NOT LOCATED ON OR OVER ANY EASEMENT OR MUNICIPAL RIGHT OF WAY. FS R# 04094 REVISION SCHEDULE 2. SITE WORK, UTILITY, AND ROADWAY INFORMATION ARE TAKEN FROM BOUNDARY AND TOPO SURVEY SITE PLANS. REFER TO C -DRAWINGS. 3• MINIMUM CONDUIT SIZE SHALL BE 3/4"C. MINIMUM CONDUCTOR SIZE SHALL BE #10AWG COPPER UNLESS OTHERWISE NOTED. 4. REFER TO BUILDING ELECTRICAL DRAWINGS FOR EXTERIOR LIGHTING CONTROL. 5. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ONLY NEW AND U.L. LABELED ELECTRICAL EQUIPMENT, UNLESS INDICATED OTHERWISE BY THE CONTRACT DOCUMENTS. 6. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL CONTACT ALL UTILITIES FOR VERIFICATION AND IDENTIFICATION OF ALL UNDERGROUND RUNS, PRIOR TO SITE TRENCHING ("CALL BEFORE YOU DIG"). 7• FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE (NFPA 70), AND THE LIFE SAFETY CODE (NFPA 101), AS ADOPTED AND/ OR AMENDED BY STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 8. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL COORDINATE AND FIELD VERIFY LOCATIONS OF ALL UTILITY SERVICE RUNS, ORIGINATIONS, TERMINATIONS AND ANY INSTALLATION REQUIREMENTS (i.e. ELECTRICAL, TELEPHONE, WATER, GAS, SEWAGE, ETC.), AS RELATED TO THIS JOB, OR THEREBY EFFECTED. NO. DATE 1 02-26-18 5 05-11-18 DESCRIPTION Agency Revision MDP Relocation Revision GRAPHIC SCALE 10 0 5 10 20 ..- IME . _.._ "= 20'-0" (IN FEET) 1 inch = 20 ft. B KEY NOTES - DRIVE-THRU CASH STATION 5/11/2018 10:24:09 AM D1 LOCATION OF A 360 DEGREE BUILDING MOUNTED EXTERIOR CAMERA (BY OTHERS). PROVIDE A 3/4" CONDUIT AT +9`-4" AFF. TO AN EXTERIOR WALL MOUNTED WEATHERPROOF JUNCTION BOX WITH THE CONDUIT ABOVE THE INTERIOR CEILING AND EXTENDED TO AN ACCESSIBLE CEILING AREA FOR CAMERA CABLES (BY OTHERS). VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. D2 PROVIDE AN EXTERIOR DUPLEX 120V, 20A GFCI-TYPE RECEPTACLE AT +18" AFF. WITH 'IN -USE' STYLE LOCKABLE WEATHERPROOF COVER. VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. ELECTRICAUCOMMUNICATIONS UTILITIES: 6...i� COORDINATE AND COMPLY WITH ALL TELEPHONE AND ELECTRICAL UTILITY REQUIREMENTS. THE FOLLOWING PERSONS SHALL BE CONTACTED FOR SPECIFIC UTILITY COMPANY REQUIREMENTS: ELECTRICAL UTILITY: PUGET SOUND ENERGY LUANNE YU (425) 806-7855 newserviceapplications@pse.com COMMUNICATIONS UTILITY : COMCAST - KATIE WENZLASS, (303) 784-7298 Katie_wenzlass@cable.comcast.com VICINITY MAP nEVIEWED � H COMPLIANCE W NFPA 70 - NEC MAY 21 2018 0PROVIDE A JUNCTION BOX +18" ABOVE ROOF LINE ON THE INSIDE PARAPET WALL ABOVE THE ROOF WITH A 3/4" CONDUIT STUBBED DOWN INTO AN ACCESSIBLE CEILING SPACE AREA BELOW FOR THE OWNER PROVIDED WI -FI EXTERIOR ANTENNA. VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. NOT TO SCALE RECEIVED CITY OF TUKWILA MAY 1 4 2018 PERMIT CENTER ARCHITECTS PROJECT # PRINTED FOR CONSTRUCTION DOCUMENTS Cl) DATE I— Issue Date Z DRAWN BY LU Designer G Information contained on this drawing and in all digital files produced for above named project U may not be reproduced in any manner without Oexpress written or verbal consent from authorized project representatives. a SHEET zz • ELECTRICAL SITE PLAN 0 cc SHEET NUMBER I— co.. z 0 .ES -1 4 1 5/11/2018 10:22:37 AM Tukwila, IWA)/04094 Tukwila, WA ELE.rvt Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage A 0 o A 5 Lithonia Lighting DSXO LED 40C 1000 30K T5S MVOLT HS DSXO LED with 40 LEDs @1000 mA , 3000K, Type 5 Short Optics with HOUSE- SIDE SHIELD LED 1 DSXO _LED 40C_100030 K T5S_MVOLT_HS.ies 12542 0.8 138 n 6 a O> B 1 Lithonia Lighting DSXO LED 40C 1000 30K T5S MVOLT HS DSXO LED with 40 LEDs @1000 mA , 3000K, Type 5 Short Optics with HOUSE- SIDE SHIELD LED 1 DSXO_LED 40C_1000_30 K T5S_MVOLT HS.ies 12542 0.8 276 o 0 V C 5 Lithonia Lighting DSXO LED 40C 1000 30K T5S MVOLT HS DSXO LED with 40 LEDs @1000 mA , 3000K, Type 5 Short Optics with HOUSE- SIDE SHIELD LED 1 DSXO_LED 40C_1000 30 K T5S_MVOLT_HS.ies 12542 0.8 276 0 D 10 Lithonia Lighting LDN4 30/10 LO4AR LSS 4IN LDN, 3000K, 1000LM, 80 CRI, CLEAR, SEMI -SPECULAR REFLECTOR LED 1 LDN430_10_LO4AR LSS. ies 941 1 12.69 /\ 0 E 13 PROGRESS P5675 -3030K 5" diameter up/down wall mount LED cylinder 40- Nichia 3000K LEDs 1 P5675- 3030K 1600018.ies 1616 0.9 32.9 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone#1 + 1.7 fc 18.0 fc 0.0 fc N/A N/A +0.0 +0.0 0.0 +0.0 0. +0.0 +0.0 +0.0 +0.0 0.0 +0.0 +0.0 +0. +0.1 ++ 0.0 0.1 +0.2 +0.3 +0.4 0.3 +0.7 +1.0 +1.8 +1.8 +1 8 -+ 0.1 +;0.1 0.1 0.4 T0.4 (l 0.0 0.0 0.0 0/ 0.1 0.7 0j+1.4 • „„ 0.0 +_- ,4// + + +0.0 1 0.0 �/ r 0.1 + + + 0.1 0.2 0.0 0. / 0.1 +0.1 +0. *'/ ++ 0.1 +0.1 0. + 2.1 4.7 + // + + 0.7, 1.9 3.1 X0.7 +1.9 +3.4 0.8 +1.9 +3.5 +0.7 +1.8 '2.7 +0.0 +0.1 i0.1 +0.1 +0.5 4- _ + >0-.1 _ _ + ). +0.3 +. 0.0 ..................... 0. \+0.1 +0.1 +0.2X0.8 +1.9 +3.6 +0.1 0.2 +{ 1.2 1.7 +0.6 4.4 4.6 +1.9 +1.3 +0 1 +0.1 0.1 X + + 0.1 0.1 001 0.3 +ll ("0:(P 0.1 +0.1 10.1 T0.1 +0.1 +0.1 0.1 +0.1 0.1 +0.1 +0.1 +0.1 +0.0 +0.0 X + 0.0 0.1 +0.1 0.1 0.1 +0.1 +0.1 +0.1 0.5 X1.4 12. 0.1 0. j0.1 0.1' /0.1 (.0. +0.2 10.4 +0.4 4.4 i2.8 +4.9 71 0.P 10.5 +1.3 2.9 +5.2 +0.4 +0.3 +0.1 0.0 +0.0 +0.0 +0.1 +0.0 0.0 ++_ + + 6.3 5.0 + . �.7 ,-- n 1 0.1 +9.0 9.2 5.1 +6.2 +1 8 '0.8 1.2 +0.5 ++ 0.2 0.3 +0.3 +0.4 0.4 0.4 0.4 3.0 1.0 0.3 0.5 1.Li i3.1 C Do D +7.7 +7.6 T7.2 +5.3 +7.41 +2.4 +4.1 +5.8 0.1 I- 0.2 0.5 +1 + .7 2.7 + ++ .5 7.7 1 1.2 0.5 +0.8 +1.5 +3.5 +5.3 +7.1 2. 1.3 0.5 +0.4 0.9 +2.1 +3.3 +3.7 + I[il ++ 0.3 0.4 1.0 1.6 +1.6 j ++ 0.8 1. {++ 0.2 0.3 0.3 + + X 0.3 0.6 0.8 +0.5 +1.2 +1.7 +0 + ' + + .1 0.2 0.7 1.8 2.7 -{0: /0.1 X0.1 +0.2 +0.8 +1.9 3.5 I I, +0.01 +0.1 {0.1 +0.2 +0.8 +1.9 +3.2 0.0 \ 0.1 `moi i0.0 ( .0 +0.0 +0.0 +0.1 0.4 0. 110.2 +0.2 +-0.3 +0.3 //0!y ./0;17/ /d //r.b fr7,1; 0.2 4.1 +0.1 0.1 0.1 0.1 +0.1 0.5 0.1 0.1 +0.2 0.1 0.1 0.1 5 T0.2 +0.1 +0.1 +0.1 +0.1 0.1 0.1 +0.1 T0.1 +0.1 +0.1 .2--:+0-.1 +0.1 +0.2 0.5 5.9 2.8 2.8 +3.7 4.4 +5.2 0.1 0.7 +1.5 2.2 +4.9 +0.1 +0.1 0.1 +0.1 0.0 +0.0 + .0 +e.0 0.0 0.0 0.0 --__Q0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 +0.8 +1.1 4.8 2.1 +2.0 +1.9 +2.0 +1.2 +0.1 +0.3 +0.3 +0.5 +0.6 + 0.9 +1.3 1///////i ///z 2 &9I" rte // 1:5 0.7 0.6 +0.9 0.5 0.5 1.5 1.4 1.6 0.1 +0.1 +0.1 +0.1 +0.3 +0.8 +1.6 +2.4 0.0 +0.0 +0.1 /0.2 +01�9 +2` + In F0.0 0.0 0.0 +0.0 +0.0 +0.1 + 4.1 7.3 0=7-1 + E� f " 2 -)1 +0.1 +05 4.0 1.6 1.1 1.3 +0.3- 0.2 0.2 0.7 +1.3 X2.9 4.3 5.3 5.3 4.2 +2.8 +1.4 +1.1 1.2 T1.2 2.2 2.6 2.8 +2.6 2.6 2.4 +1.8 +1.6 +1.8 2.2 +2.6 2 .8 2.9 +2.I I \+2.6 .F.+.I . 1.3 1.5I I }2.3 +1.1 +0.4 +0.3 I 0.3 +0. 5 + 1.1 +2.4 I- +2.3 +1.3 +2.4 1.3 T0.8 T0.4 +0.7 2.0 1.3 0.6 0.7 1! 0.0 0.0 +0.0 0.0 + 1{ 0.11 0.1 0.6 .5 1.6 + +00 0 0 0 0 0 0 1.7 +0.7 1(.9 3.4 +5.0 5.0 + + 3.3 5.2 5.3 ++ 3.0 4.0 3.8 3. Z.7 0.7 +1.4 \2. 2.1 0.9 0.3 0 + + + + + '- + ` 0�=== -s• 2.2 3.9 5.2 5.0 3.4 1.7 0.7 0.4 0.7 1.0 0.9 +0.9 0.8 0.0 0.0 I 3.4 4.9 +4.8 3.8 2.3 +0.9 +0.3 +0.1 +0.1 +0.2 +0.7 +1.6 +1.9 +1.5 '1.0 +0.5 +0.2 +0.1 +0.1 +0.2 +0.2 0.2 10.2 0.2 0.0 0.0 +0.0 +0.0 +0.2 +0.5 +0.5 +0.3 +0.2 +0.1 +0.1 +0.1 h0.1 +0.1 +0.1 +0.0 +0.1 +0.1 {0.1 +0.0 0.0 +0.0 T0.0 +0.0 +0.0 0.0 +0.0 +0.0 +0.0 0.0 +0.0 +0.1 +0.1 +0.1 +0.1 ++ 0.1 0.1 T0.1 +0.1 +0.0 +0.1 T0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1+ 0.0 00.0 .0�1) 0.0 +0.0 +0.0 0.0 0.0 +0.0 +0.0 0.0 0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.1 +0.1 +0.1 +0.1 0.0 a C � I- 1-7 PHOTOMETRIC SITE PLAN 1". 20'-0" +0.0 +0.1 {0.1 ++ 0.1 0.1 GRAPHIC SCALE 10 0 5 10 20 40 - NMI 111111111111111 MN NMI 1111111111111B (IN FEET) 1 inch = 20 ft. 0.0 '0.0 T0.0 0.0 �\ 0.0 0.0 0.0 UPDATED PHOTOMETRICS REVIEWED FOR COMPLIANCE WITH NFPA 70 m NEC MAY 21 2010 City 6fTukvuil BUILDING DIVISIIk E D Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 PROJECT MEP, INC. CONSULTING ENGINEERS Mechanical - Electrical - Plumbing 1221 E. Dyer Rd. Suite 260 Santa Ma, CA 92705-5654 (949) 428-8800 B A V g3 T (10a>' Lio �a C 1- 0 8 as 0 cn s� "' ti FS R# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION 1 02-26-18 Agency Revision 5 05-11-18 MDP Relocation Revision RECEIVED CITY OF TUKWIL , MAY 1 4 2018 PERMIT CENTER ARCHITECTS PROJECT # PRINTED FOR CONSTRUCTION DOCUMENTS - (/) DATE I- Issue Date Z DRAWN BY W Designer 2 Information contained on this drawing and in all digital files produced for above named project U may not be reproduced in any manner without Oexpress written or verbal consent from authorized project representatives. o SHEET o PHOTOMETRIC SITE PLAN U cc SHEET NUMBER I- C/) U .ES-2 E B A FOUR (2") EMPTY CONDUIT FROM CEILING SPACE DOWN WALL AND TURN INTO \\ COUNTER'S UTILITY CHASE FOR DATA AND POWER FOUR 2" CONDUIT FOUR 2" \ CONDUIT A+X DT (MLOP) LANE CONTROL STATION TO RECEPTACLES AT SERVICE AREA ENTRY TWO 1.5" CONDUIT X=21'-8" Y=31-2" THE TWO 1.5" ARE FOR THE BRANCH CIRCUITS FROM PANELS A AND B FOR EQUIPMENT ITEMS UNDER THE PASS-THRU WINDOW 4 X j MAIN TELEPHONE BACKBOARD "MTBE" / PHONE/CABLE SERVICE ENTRANCE CONDUIT -VERIFY LOCATION SIZE AND QUANTITY WITH THE ELECTRICAL SITE PLAN 1" CONDUIT THE 1" CONDUIT IS FOR THE CAPTURE JET FAN LOCATED UNDER THE FRY HOLDING STATIONS BRANCH CIRCUIT COMMUNICATIONS UTILITY SERVICE ENTRANCE CONDUITS SEE ES -1 B-38 meals TO RECEPTACLES AT PLAYGROUND AREA 2" CONDUIT FROM THE DT ORDERING AREA TO "Cl" 6" BEVERAGE CHASES BY OTHERS (TYP), SEE PLUMBING DRAWINGS FOR EXACT LOCATION AND QUANTITY FOUR 2" CONDUIT X=T -1" 2" CONDUIT FROM THE POLE MOUNTED 7/ PROVIDE A 120 VOLT CAMERAS CONNECTION TO THE 50 VA KITCHEN KITCHEN MOTORIZED DAMPER FOR THE OFFICE FROM A GEN PURPOSE RECEPTACLE CIRCUIT, REFER TO SHEET E-501 MULTI-PURPOSE EXTEND CONDUIT CEILING SPACE E (sio> BACK ENTRY 1" CONDUIT PANELBOARD "A" REFER TO SHEET E-501 PANELBOARD "B" REFER TO SHEET E-501 PANELBOARD ALL CONDUITS STUB -UPS IN THIS WALL TO BE INTO THE SERVING AREAS CEILING SPACE TWO (4") CONDUIT ABOVE CEILING FROM JUNCTION BOX ABOVE THE OFFICE CEILING TO A J -BOX ABOVE THE ASSEMBLY TABLE TO A J -BOX AT THE SERVING AREA WALL FREEZER COOLER ELECTRIC POWER UTILITY I SERVICE ENTRANCE CONDUIT(S) COORDINATE EXACT ROUGH -IN LOCATION WITH SHOP DRAWINGS OF DISTRIBUTION PANEL. UNISEX "A" OFFICE RR VEST. PANELBOARD "C" REFER TO SHEET E-501 UNISEX "B" 5200 Buffington Road Atlanta, Georgia 30349-2998 PROJECT MEP, INC. CONSULTING ENGINEERS Mechanical - Electrical - Plumbing 1221 E. Dyer Rd. Suite 260 Santa Ana, CA 92705-5654 (949) 428-8800 TO RECEPTACLES AT SERVICE AREA ENTRY SERVING AREA 444 /SECURITY KEYPAD, PROVIDE J -BOX AND 1/2" C STUB -UP TWO (2") EMPTY CONDUIT fq3 ) FROM CEILING SPACE \—/ DOWN WALL TO COUNTER FOR DATA AND POWER DINING AREA COMMUNITY ,BOARD. VERIFY ;EXACT LOCATION •HEIGHT PRIOR TO PROVIDE A 120 VOLT CONNECTION TO THE 50 VA MOTORIZED DAMPER FOR THE PLAY AREA FROM A GEN PURPOSE RECEPTACLE CIRCUIT 38 6" BEVERAGE CHASES BY OTHERS (TYP), SEE PLUMBING DRAWINGS FOR EXACT LOCATION AND QUANTITY SIGN G A-47 ITEMS OF IMPORTANCE : CONTRACTOR SHALL COORDINATE WITH THE DINING,AREKSEATING PACKAGE FOR TH LOCATIONS OF RECEPTACLES IN THE DIN,LG AREA AT TABLES SO THAT THE RECEPTACLE IS UNDER THE TABLETOP AND NOT BEHIND A BOOTH SEAT ' MAIN DITRIBUTION PANEL "MDP" REFER TO SINGLE LINE DIAGRAM, • SHEET E-502. VERIFY LOCATION WITH ) SITE PLAN AND COORDINATE WITH - THE ARCHITECTURAL ELEVATIONS. PLAY AREA BENCHMARK FOR THE ROUGH -IN COORDINATE TAKEN FROM OUTSIDE - FACE OF FRAMING B-29; 20/1 03 SIDE ENTRY AIR CURTAIN WITH MICROSWITCH TO RECEPTACLES FURNISHED BY DIVISION 15, SEE SHEET M-201 & M-401 FOR AT MAIN ENTRY ADDITIONAL INFORMATION. KEY NOTES - SECURITY: PROVIdE SINGLE GANG JUNCTION BOX AND STAINLESS STEEL COVER PLATE WITH 7/8" HOLE IN CENTER. EXTEND 1" E.C. UP IN WALL TO ABOVE ACCESSIBLE CEILING. • PROVIDE 4"W X 4"H X 3"D FLUSH JUNCTION BOX WITHOUT COVERPLATE. EXTEND 2" RIGID CONDUIT UP TO ABOVE ACCESSIBLE OFFICE CEILING AREA AND PROVIDE BUSHING ON CONDUIT END. • PROVIDE A 4"W X 4"H X 3" D JUNCTION BOX WITHOUT COVERPLATE AND EXTEND A 2" CONDUIT DOWN AND BELOW GRADE TO EACH OF THE SITE'S POLE MOUNTED CAMERA LOCATIONS (SEE ELECTRICAL SITE PLAN FOR CONTINUATION) AND A 2" CONDUIT UP INTO THE ACCESSIBLE CEILING SPACE WITH A BUSHING ON THE CONDUIT END. PROVIDE A SINGLE -GANG JUNCTION BOX ADJACENT TO THE DOUBLE -GANG BOX WITH A 1.5" CONDUIT DOWN TO A SECOND SINGLE -GANG JUNCTION BOX AT THE CCTV MONITOR LOCATION. PROVIDE TWO GANG WEATHERPROOF JUNCTION BOX AND STAINLESS STEEL PLATE WITH 7/8" HOLE IN CENTER FOR PANIC BUTTON. MOUNT AT APPROXIMATELY 48" A.F.F., EXTEND 1/2" RIGID CONDUIT OVER TO THE WALL AND THEN UP TO ABOVE ACCESSIBLE CEILING. SEAL PENETRATION AT WICNVIF CEILING. c PROVIDE SINGLE GANG BOX WITHOUT COVER PLATE. EXTEND 1/2" CONDUIT UP IN WALL TO ABOVE ACCESSIBLE CEILING AND TURN TOWARD SERVING AREA SIDE OF WALL. • PROVIDE SINGLE GANG JUNCTION BOX ON INSIDE FACE OF PARAPET WALL APPROX. 12" BELOW TOP OF PARAPET WALL. EXTEND 1/2" CONDUIT DOWN TO ABOVE ACCESSIBLE OFFICE CEILING. EXTEND 1/2" RIGID CONDUIT FROM TOP OF STRIKE -SIDE DOOR FRAME CHANNEL TO ABOVE ACCESSIBLE CEILING. EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" WITHIN EITHER HINGE -SIDE DOOR VERTICAL FRAME MULLION TO ABOVE ACCESSIBLE CEILING. PROVIDE SINGLE GANG JUNCTION BOX WITHOUT COVERPLATE. EXTEND 1/2" CONDUIT UP IN WALL TO ABOVE ACCESSIBLE CEILING AND TURN TOWARD SERVING AREA SIDE OF WALL. PROVIDE SINGLE GANG, WEATHER-PROOF JUNCTION BOX WITH STAINLESS STEEL COVER PLATE MOUNTED 18" FROM THE CORNER OF THE SERVICE AREA AND JUST BELOW ROOF DECK MOUNTING BRACKETS. ROUTE 1" EMT CONDUIT FROM THE BOX SURFACE MOUNTED JUST BELOW THE ROOF DECK MOUNTING BRACKETS AND TERMINATE THE CONDUIT AT a) EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" WITHIN STRIKE -SIDE WINDOW FRAME MULLION TO ABOVE ACCESSIBLE CEILING. PROVIDE SINGLE GANG, WEATHER-PROOF JUNCTION BOX WITH STAINLESS STEEL COVER PLATE MOUNTED JUST ABOVE THE STRIKE SIDE OF OUTSIDE DOOR ON INSIDE OF SERVICE AREA. ROUTE 1" EMT CONDUIT SURFACE MOUNTED FROM BOX JUST BELOW THE ROOF DECK MOUNTING BRACKETS. TERMINATE CONDUIT IN THE ACCESSIBLE CEILING SPACE INSIDE THE BUILDING. EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" INSIDE THE STRIKE -SIDE DOOR FRAME MULLION TO ABOVE ACCESSIBLE CEILING. ,f1j PROVIDE JUNCTION BOX ON THE LATCH SIDE OF THE ROOF ACCESS HATCH WITH 1/2" C ABOVE THE CEILING TO THE OFFICE CEILING SPACE FOR A DOOR CONTACT. CO CV 38 A-49 49 WP/GFI CV MAIN ENTRY -- 0 POWER AND SYSTEMS PLAN AIR CURTAIN WITH MICROSWITCH FURNISHED BY DIVISION 15, SEE SHEET M-201 & M-401 FOR— ADDITIONAL INFORMATION. -- STRUCTURAL SILL PLATE NOTE KEY NOTES - COMMUNICATIONS: g PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC2OORR), ONE WITH 3" CONDUIT STUBBED UP INTO THE CEILING SPACE FOR VIDEO AND ONE WITH A 2" CONDUIT STUBBED UP INTO THE CEILING SPACE FOR AUDIO AND DETECTOR LOOP. (g PROVIDE JUNCTION BOX, LESS COVER PLATE, AND EXTEND 1" E.C. UP IN WALL TO ABOVE CEILING FOR INSTALLATION OF WIRELESS COMMUNICATION CONTROL UNIT. rg PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC2OORR) WITH STAINLESS STEEL COVER PLATE AND HOLE IN PLATE FOR AUDIO WITH 2" CONDUIT TO THE DT DUAL -LANE ORDERING AREA AND A 2" CONDUIT STUBBED UP INTO THE CEILING SPACE. PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC2OORR) WITH STAINLESS STEEL COVER PLATE AND HOLE IN PLATE FOR VIDEO WITH 3" CONDUIT TO THE DT DUAL -LANE ORDERING AREA AND A 3" CONDUIT STUBBED UP INTO THE CEILING SPACE. Kg. PROVIDE SINGLE GANG BOX WITH 3/4" EMPTY CONDUIT STUB -UP INTO ACCESSIBLE CEILING SPACE FOR OWNER DRIVE-THRU HARD -WIRED BACKUP AUDIO SYSTEM. t-5) PROVIDE SINGLE GANG JUNCTION BOX WITH 3/4" C. STUP-UP INTO ACCESSIBLE CEILING SPACE. KEY NOTES - MUSIC: ch PROVIDE JUNCTION BOX WITH STAINLESS STEEL COVER PLATE AND 3/4" HOLE IN PLATE WITH GROMMET ON HOLE IN PLATE. EXTEND 3/4" E.C. UP IN WALL TO ABOVE CEILING FOR MUSIC SYSTEM. PROVIDE THREE SINGLE GANG EXTRA DEEP JUNCTION BOXES STACKED ABOVE EACH OTHER WITH 1/2" CONDUIT FROM EACH TO THE TOP BOX AND A 1" CONDUIT STUBBED INTO THE CEILING SPACE. FOR MUSIC SYSTEM VOLUME CONTROLS. c* PROVIDE A SINGLE GANG EXTRA DEEP JUNCTION BOX AT 74" AFF WITH 1/2" CONDUIT STUBBED INTO THE CEILING SPACE. FOR MUSIC SYSTEM VOLUME CONTROLS. (4 KEY NOTES - POS SYSTEM: (Fa --1) PROVIDE A 'RETROFIT' DOUBLE -GANG RING (CARLON #SC2OORR) FOR OWNER'S DEVICE PLATE WITH A 3" EMPTY CONDUIT AT THE OPENING IN THE WALL UP TO THE CEILING SPACE FOR OWNER'S DATA CABLES. g PROVIDE JUNCTION BOX FOR TERMINATION OF 1" CONDUIT. PROVIDE 1" CONDUIT EXTENDING FROM CEILING AND TERMINATED AT JUNCTION BOX ON THE SERVING AREA SIDE OF THE WALL. COVER PLATE PROVIDED BY OWNER'S POS SYSTEM VENDOR. 44 PROVIDE TWO 2" CONDUIT FROM THE JUNCTION BOX ABOVE THE CEILING, DOWN THE WALL, BELOW THE FLOOR, AND TURN UP INTO THE CABLE AREA OF THE CASEWORK FOR OWNERS DATA CABLES. '1.4') PROVIDE A 'RETROFIT' SINGLE GANG RING (CARLON #SC10Orr) FOR OWNER'S DEVICE PLATE WITH A 2" EMPTY CONDUIT AT THE OPENING IN THE WALL UP TO THE CEILING SPACE FOR OWNER'S DATA CABLES. PROVIDE JUNCTION BOX FOR TERMINATION OF 1" CONDUIT. PROVIDE 1" CONDUIT EXTENDING FROM CEILING AND TERMINATED AT JUNCTION BOX ON THE SERVING AREA SIDE OF THE WALL. POS SYSTEM SUPPLIER WILL PROVIDE COVER PLATE ON BOX. * PROVIDE SINGLE GANG EXTRA DEEP JUNCTION BOX MOUNTED ON THE MOUNTING PLATE WITHIN THE FRONT SERVING COUNTER CASEWORK. MOUNT BOX ADJACENT TO THE RECEPTACLE FOR EQUIPMENT 201. DO NOT MOUNT BOX BETWEEN EQUIPMENT 201 AND EQUIPMENT 204 RECEPTACLES. GENERAL NOTES: ALL SECURITY, POS, MUSIC, COMMUNICATIONS, AND POWER ROUGH -IN SHALL BE INSTALLED DURING THE FRAMING/ROUGH-IN PHASE OF CONSTRUCTION. 2. REFER TO KITCHEN EQUIPMENT SHEETS FOR EQUIPMENT ELECTRICAL ROUGH -IN ELEVATIONS ABOVE FINISHED FLOOR. 3. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH PULL STRING. 4. pROVIDE INSULATED BUSHINGS AT TERMINATION POINTS OF ALL CONDUITS FOR LOW VOLTAGE WIRING. 5. THE ELECTRICAL INSTALLER SHALL COORDINATE THE ROUTING OF ALL CONDUIT IN THE BUILDING WITH OTHER TRADES (SPECIFICALLY THE DUCTWORK INSTALLATION) TO AVOID CONFLICTS OF SPACE REQUIREMENTS IN WALLS AND CEILING SPACES. 6. ALL RECEPTACLES SHALL BE PIGTALED. FEED THROUGH OF BRANCH CIRCUIT WIRING, THROUGH RECEPTACLE DEVICE, SHALL NOT BE PERMITTED. UNDERSLAB ROUGH -IN NOTES: 1. THE ROUGH -IN DIMENSIONS ARE BASED ON THE PROTOTYPICAL CASEWORK AND CURB LOCATIONS. VERIFY WITH THE SPECIFIC SITE THAT THE LOCATIONS HAVE NOT BEEN ALTERED OR CHANGED. 2. COORDINATE WITH THE PROJECTS PLUMBING INSTALLER TO AVOID CONFLICTS WITH UNDERSLAB PIPING AND BEVERAGE CHASE LOCATIONS. 3. ALL UNDERSLAB CONDUITS SHALL HAVE LONG SWEEP ELBOWS. 4 EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. FOR POWER PLAN KEY NOTES, REFER TO SHEET E-301. CONDUITS PENETRATING PERIMETER SILL PLATES SHALL BE LOCATED AT LEAST 10" CLEAR FROM AN EDGE OF A WALL OPENING REFER TO THE ELECTRICAL SITE PLAN FOR ADDITIONAL REQUIREMENTS FOR THE DRIVE-THRU CASH STATION ("D" KEYNOTES) ELECTRICAL KEY PLAN REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC 2 1 S 1 MAY 2 1 2010 City of Tukwila BUILDING DIVISION 88 eg as ..c 70) FS R# 04094 REVISION SCHEDULE NO. DATE 1 02-26-18 5 05-11-18 DESCRIPTION Agency Revision MDP Relocation Revision RECEIVED CITY OF TUKWiLA MAY 1 4 2018 PERMIT CENTER ARCHITECTS PROJECT # PRINTED FOR CONSTRUCTION DOCUMENTS Issue Date Z DRAWN BY Designer 2 Information contained on this drawing and in all = digital files produced for above named project 0 may not be reproduced in any manner without express written or verbal consent from %-1 authorized project representatives. SHEET z POWER AND p- SYSTEMS PLAN cc SHEET NUMBER 0 E-221 0 11/9/2017 5:01:20 PM E D C B A 1. 2. KEY NOTES -ELECTRICAL SITE PLAN (APPLIES TO THE ELECTRICAL SITE PLAN ONLY) PRIMARY UNDERGROUND ELECTRICAL UTILITY LINES. REFER TO SHEET E-502 FOR ADDITIONAL REQUIREMENTS. UTILITY TRANSFORMER AND SLAB BOX. THE ELECTRICAL CONTRACTOR SHALL PROVIDE: A. SECONDARY SERVICE LATERAL FROM POWER UTILITY COMPANY TRANSFORMER TO MAIN DISTRIBUTION PANEL 'MDP'. PROVIDE FOUR (4) 4"C.O., (SCH. 40 PVC CONDUIT) TO UTILITY SOURCE, AT MINIMUM 30" BELOW FINISHED GRADE AND IN ACCORDANCE WITH UTILITY COMPANY REQUIREMENTS. CONDUCTORS SHALL BE INSTALLED AND CONNECTED BY POWER UTILITY COMPANY. COORDINATE ALL REQUIREMENTS WITH POWER UTILITY COMPANY) PRIOR TO BID. REFER TO SHEET E-502, "SINGLE -LINE DIAGRAM", AND, "ELECTRICAL SERVICE LATERAL CONDUIT DETAIL", ON SHEET E-001 FOR ADDITIONAL INFORMATION. B. CONCRETE SLAB BOX FOR UTILITY TRANSFORMER IN ACCORDANCE WITH POWER UTILITY COMPANY REQUIREMENTS. REFER TO SHEET E-502 FOR ADDITIONAL REQUIREMENTS. 3. LOCATION OF TERMINATION OF SECONDARY SERVICE LATERAL AT PANEL 'MDP'. REFER TO "SINGLE -LINE DIAGRAM", SHEET E-502, FOR ADDITIONAL INFORMATION. 4. PROVIDE ONE (1) 4" SCH. 40 PVC CONDUIT FOR TELEPHONE/CATV/ISP SERVICE CONNECTION AND ONE (1) SPARE 4" SCH. 40 PVC CONDUIT. INSTALL CONDUITS MINIMUM 24" BELOW FINISHED GRADE, FOR SERVICE FROM COMMUNICATIONS UTILITY SOURCE(S) TO JUNCTION BOX(ES) WITHIN BUILDING. REFER TO SHEET E-221 FOR LOCATION OF TERMINATIONS. REFER TO "COMMUNICATIONS UTILITY SERVICE CONDUIT DETAIL", ON SHEET E-001, FOR ADDITIONAL INFORMATION. COORDINATE EXACT LOCATION OF UTILITY SOURCE(S) WITH COMMUNICATIONS UTILITIES. TERMINATE CONDUITS AT UTILITY SOURCE AS REQUIRED BY THE UTILITY COMPANIES. 5. LOCATION OF TRASH ENCLOSURE. REFER TO "REFUSE ENCLOSURE PLAN - ELECTRICAL", SHEET E-250 FOR ELECTRICAL REQUIREMENTS IN THIS AREA. 6. 7. REFER TO SHEET E-004 FOR ELECTRICAL REQUIREMENTS AT MENU BOARD AND DRIVE-THROUGH CANOPY. CONNECTION OF EQUIPMENT GROUNDING CONDUCTOR SHALL BE MADE IN ACCORDANCE WITH 250.130 IN A METHOD SPECIFIED IN 250.8 OF THE NATIONAL ELECTRICAL CODE. BOND METAL PARTS OF THE SIGN TO THE GROUNDING CONDUCTOR OF THE BRANCH CIRCUIT IN ACCORDANCE WITH 250.180 OF THE NATIONAL ELECTRICAL CODE. MOUNT AND AIM FLAG POLE LUMINAIRE FOR 360 -DEGREE ILLUMINATION OF FLAGS. AIM AT NIGHT. REFER TO DETAIL #6, E-001 FOR ADDITIONAL REQUIREMENTS. 8. REFER TO SHEET E-221 FOR EXTERIOR LIGHTING IN PATIO DINING AREA. 9. PROVIDE CONDUIT TO JUNCTION BOX IN OFFICE FOR POLE MOUNTED SECURITY CAMERA. REFER TO SHEET E-221 FOR LOCATION OF JUNCTION BOX IN OFFICE AND REQUIRED SIZE OF CONDUIT. COORDINATE EXACT CAMERA LOCATION WITH CHICK-FIL-A SECURITY SYSTEM REPRESENTATIVE PRIOR TO ROUGH -IN. 10. ROUTE SITE LIGHTING CIRCUITS THROUGH THE "T-500" LIGHTING CONTROL PANEL (TYPICAL). REFER TO LIGHTING CONTROL DIAGRAM ON SHEET E-002, AND PANEL SCHEDULES ON SHEET E-501. i1. COORDINATE LOCATIONS OF ALL SIGNS WITH CHICK-FIL-A REPRESENTATIVE PRIOR TO BID AND PRIOR TO CONDUIT INSTALLATION. 12. PROVIDE GFCI TYPE WEATHERPROOF RECEPTACLE MOUNTED ON MAIN SIGN SUPPORT +14" AFG. THIS RECEPTACLE SHALL NOT BE SWITCHED. (BYPASS THE CONTACTOR AND SIGN'S DISCONNECT SWITCH.) 13. PROVIDE WEATHERPROOF 20A SPST TOGGLE SWITCH 18" AFG AND CONNECTION TO MAINTENANCE DISCONNECT SWITCH FOR MAIN I.D. SIGN. 14. PROVIDE WEATHERPROOF 20A SPST TOGGLE SWITCH 18" AFG AND CONNECTION TO MAINTENANCE DISCONNECT SWITCH FOR DIRECTIONAL. SIGN. CONNECTION OF EQUIPMENT GROUNDING CONDUCTOR SHALL BE MADE IN ACCORDANCE WITH 250.130 IN A METHOD SPECIFIED IN 250.8 OF THE NATIONAL ELECTRICAL CODE. BOND METAL PARTS OF THE SIGN TO THE GROUNDING CONDUCTOR OF THE BRANCH CIRCUIT IN ACCORDANCE WITH 250.90 AND 250.8 OF THE NATIONAL ELECTRICAL CODE. 15. REFER TO BUILDING DRAWING E-221 FOR LAYOUT OF THE SERVICE AREA. COORDINATE LOCATIONS OF ALL ITEMS AT THE SERVICE YARD AREA PRIOR TO ROUGH -IN OF ANY ITEMS INSTALLED ON OR NEAR THE SERVICE YARD. COORDINATE EXACT LOCATIONS OF SECURITY SYSTEM EQUIPMENT WITH CHICK-FIL-A SECURITY SYSTEM REPRESENTATIVE PRIOR TO ROUGH -IN. 16. PROVIDE #10 CONDUCTORS, ENTIRE CIRCUIT LENGTH. 1. 2. 3. GENERAL ELECTRICAL SITE PLAN NOTES (APPLIES TO THE ELECTRICAL SITE PLAN ONLY) VERIFY WITH LOCAL AUTHORITIES AND UTILITIES THAT OWNER'S SIGNS, POLES, AND THEIR APPURTENANCES ARE NOT LOCATED ON OR OVER ANY EASEMENT OR MUNICIPAL RIGHT OF WAY. SITE WORK, UTILITY, AND ROADWAY INFORMATION ARE TAKEN FROM BOUNDARY AND TOPO SURVEY SITE PLANS. REFER TO C -DRAWINGS. MINIMUM CONDUIT SIZE SHALL BE 3/4"C. MINIMUM CONDUCTOR SIZE SHALL BE #10AWG COPPER UNLESS OTHERWISE NOTED. 4. REFER TO BUILDING ELECTRICAL DRAWINGS FOR EXTERIOR LIGHTING CONTROL. 5. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ONLY NEW AND U.L. LABELED ELECTRICAL EQUIPMENT, UNLESS INDICATED OTHERWISE BY THE CONTRACT DOCUMENTS. 6. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL CONTACT ALL UTILITIES FOR VERIFICATION AND IDENTIFICATION OF ALL UNDERGROUND RUNS, PRIOR TO SITE TRENCHING ("CALL BEFORE YOU DIG"). FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE (NFPA 70), AND THE LIFE SAFETY CODE (NFPA 101), AS ADOPTED AND/ OR AMENDED BY STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 7. 8. FOR WORK UNDER THIS DIVISION, ELECTRICAL CONTRACTOR SHALL COORDINATE AND FIELD VERIFY LOCATIONS OF ALL UTILITY SERVICE RUNS, ORIGINATIONS, TERMINATIONS AND ANY INSTALLATION REQUIREMENTS (i.e. ELECTRICAL, TELEPHONE, WATER, GAS, SEWAGE, ETC.), AS RELATED TO THIS JOB, OR THEREBY EFFECTED. KEY NOTES - DRIVE-THRU CASH STATION 0 LOCATION OF A 360 DEGREE BUILDING MOUNTED EXTERIOR CAMERA (BY OTHERS). PROVIDE A 3/4" CONDUIT AT +9'-4" AFF. TO AN EXTERIOR WALL MOUNTED WEATHERPROOF JUNCTION BOX WITH THE CONDUIT ABOVE THE INTERIOR CEILING AND EXTENDED TO AN ACCESSIBLE CEILING AREA FOR CAMERA CABLES (BY OTHERS). VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. D2 PROVIDE AN EXTERIOR DUPLEX 120V, 20A GFCI-TYPE RECEPTACLE AT +18" AFF. WITH 'IN -USE' STYLE LOCKABLE WEATHERPROOF COVER. VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. 0 PROVIDE A JUNCTION BOX +18" ABOVE ROOF LINE ON THE INSIDE PARAPET WALL ABOVE THE ROOF WITH A 3/4" CONDUIT STUBBED DOWN INTO AN ACCESSIBLE CEILING SPACE AREA BELOW FOR THE OWNER PROVIDED WI -Fl EXTERIOR ANTENNA. VERIFY EXACT LOCATION IN FIELD PRIOR TO INSTALLATION. / n FEEDER "PF" \ REFER TO SINGLE LINE DIAGRAM, SHEET E-502 UTILITY TRANSFORMER AND SLAB BOX. REFER TO SINGLE LINE DIAGRAM, SHEET E-502 00 0 MAIN DISTRIBUTION PANEL "MDP" SEE SINGLE LINE DIAGRAM, E-502 MAIN TELEPHONE BACKBOARD "MTBB" SEE SHEET E-211 FLAG POLE C-25 00 2#10,1#10GND.-3/4"C. C-21,23 3#10,1 #10GND.-3/4"C. 000 FEEDER "SF" REFER TO SINGLE LINE DIAGRAM SHEET E-502 \ 6 )MENU BOARD C-12 2#10,1#10GND.-3/4"C. REFUSE ENCLOSURE REFER TO DETAIL #2, SHEET E-250 3 DIRECTIONAL SIGN DIRECTIONAL SIGN ELECTRICAL SITE PLAN 1". 20'-0" EXISTING PARKING n GRAPHIC SCALE 10 0 5 10 20 ELECTRICALICOMMUNICATIONS UTILITIES: COORDINATE AND COMPLY WITH ALL TELEPHONE AND ELECTRICAL UTILITY REQUIREMENTS. THE FOLLOWING PERSONS SHALL BE CONTACTED FOR SPECIFIC UTILITY COMPANY REQUIREMENTS: ELECTRICAL UTILITY: PUGET SOUND ENERGY LUANNE YU (425) 806-7855 newserviceapplications@pse.com COMMUNICATIONS UTILITY : COMCAST KATIE WENZLASS, (303) 784-7298 Katie_wenzlass@cable.comcast.com 40 ( IN FEET ) 1 inch = 20 ft. OB I I, �(E) FILE COPY Permit No. twi'm� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVISIONS I No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: oMethanicai ieGtrtCal LE Plumbing I'Gas Piping City of Tukwila Bl rl_D° DIVISION SOUTHCENTER PKWY C-39,41,4311 4#10,1#10GND: 3/4"C. MONUMENT SIGN VICINITY MAP NOT TO SCALE RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER Ev}.- octi4 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 D C A 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of.Tukwila BUILDING DIVISION City of Tukwii BUILDING DIVIce' _: o gym-+ v a) DESCRIPTION ARCHITECT'S PROJECT # 1/#4## PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET ELECTRICAL SITE PLAN CL SHEET NUMBER . ES -1 11/9/2017 5:03:34 PM Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage g A 15 Lithonia Lighting DSXO LED 40C 1000 30K T5S MVOLT HS DSXO LED with 40 LEDs @1000 mA , 3000K, Type 5 Short Optics with HOUSE- SIDE SHIELD LED 1 DSXO_LED_40C_1000_30 K T5S_MVOLT_HS.ies 12542 0.8 138 O B 4 Gotham Architectural Lighting AFV 32TRT 4AR MVOLT OPEN 4" VERTICAL FLUORESCENT 32 WATT DOWNLIGHT. ONE 32 -WATT COMPACT FLUORESCENT , VERTICAL BASEUP POS. 1 AFV_32TRT_4AR_MVOLT.i es 2400 0.9 33 OC 14 PROGRESS P5675 -3030K 5" diameter up/down wall mount LED cylinder 40- Nichia 3000K LEDs 1 P5675- 3030K_1600018.ies 1616 0.9 32.9 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 + 2.4 fc 11.6 fc 0.0 fc N/A N/A +0.0+ I +0.0 0.0 +0.0 0.0 �' 0.1 0.1 + + 0.1 0.1 +0.0 +0.0 0.0 0.0 1 Ii +0.1 + + +0.4 Ii 0.2 0.3 + + + /// 0.0 0.0 0.0 0.1 0.1 1 0.3 0.7 1.0 1.8 +++ 0.0 0.0 0.1 +� 1 +0.1 +" +++ 0.1 0.1 0.1 0.4 . +..2- + + .1 + 0.1 7 2-±tr4 +0.4 •r2_8 +4:9 --_+3.6 +0.1 +0.1 +0.1 + + + + + + + + 0.1 0.1 0.1 0.1 0.1 0.1 0.5 1 4 8 +1.0 +0.7 +0.3 +0.1 0.1 0.1 +0.1 7' 0.4--±02---±-0-.31-1-±01. 0.0 0.0 2.0 +0.1 +0.6 1.4 2.1 4.7 0 4 10.4 0.6 1.5 0.1 0.1 +0.0 +0.0 +0.1 / 0.1 +0.2 +0.0 +0.1 +0.1 +0.1 +0.1 +0.3 +0.7 +1.8 3.1 ++ 0.1 0.3 /0.8 +1.9 3.4 +0.1 +0.1 +0.7 +1.6 +0.1 +0.2 +1.4 3.3 +0.9 +2.3 +5.3 +9. 9.9 +7.8 4.9 0.3 +0.9 +2.2 5.210.6 + 11 + + 10.8 7.3 4.2 5.2 +8.9 +9.1 + + I 7.4 4.9 + ; + + + 3.7 5.4 1 5.8 5.9 4.9 +1.3 2.4 4.0 2.1 3.3 3.8 +1 + + i 1.3 2.9 5.2 I 11 +6.3 +5.0 05 14 +0.3 +0.1 CC 2.4 4.1 +5.8 9. A 9.L 0.4 p.1 0.7 1.5 3.5 5.4 7.5 7.2 +7.0 3.7 3.9 3.6 4. +0.3 +0.9 +0.3 +0.9 +i 8 I +0.2 0.i +1.3 0.1 +0.1 0.1 0.1 0 2.0 +2.6 3.2 4.4 4.6 0.4 +0.6 +0.9 +1.5 2.6 4.2 44 +1.1 2.1 3.2 -;:0-2L-21. +4. 3. 9.7 4.1 2.9 3.4 4.2 +5. P12 LC LPG 121 SEATS W/ PLAYGROUND GSF 5,134 S.F. 0.2 pi 0.4 1.0 2.1 3.6 C 0.4 + 0.2 10.2 C C +0.2 L 0.2 +0.3 +0.9 +2.2 3.5 +4. 0.1 0.1 10 8.2 4.1 2.8 2.9 3.4 5.1 7. 0 +9.3 4.0 3.0 3.6 +4.3 +5.4 6. 5.9 3.0 2.9 3.9 +4.5 +5.2 C +0.2 +0.3 +1.0 2.3 A 0.3 +0.4 +0.6 +1.2 2.3 3.9 +9.9 0.7 1.2 2.0 2.6 3.8 5.0 +9.0 0.6 1.2 2.0 4. 4.7 5.7 5.5 + +1 + + + + 0.6 1.5 2.8 7.2 7.4 7.8 6.1 +4.7 0.1 0.6 +1.4 3.1 903 +10.7 +9.6 5.9 3. j+0.1 0.5 1.4 + .5 1.1 1.3 0.4 0 4 2.7 2.1 1.3 1.0 0.6 0.6 1.4 +1.5 +1.5 +1.7 + 1.5 3.2 4.5 +5.3 +5.3 2.6 +1.3 +1.1 +3.1 +4.9 7.1 +7.2 +7.3 +0.1 0 1 01 0. 2.3 2.7 +2.9 2.6 2.6 +2.3 +1.8 +1.6 +1.8 +2.3 +9.0 +7.9 +9.2 +5.6 2.7 +1.0 +1.0 0.0 0.0 3.7 2.0 ++ 1.8 1.3 +0r5 +0 8 0 1.7 2.4 +2.6 9.1 +3.3 +0.9 +0.6 +0.3 2.8 114.5 2.9 12.7 I 2.1 3.6 \2.3 +1.1 3.4 4.9 4.8 0.0 0.0 0.1 0.1 0.2 +0.2 +0.2 0.3 +0.2 +0.1 +0.2 +0.5 +0.5 +0.4 0.0 0.0 +0.0 +0.0 0.0 0.0 0.1 +0.1 +0.1 0.1 +0.1 111 +0.1 +0.1 +0.1 +0.1 +1.5 j +1.3 1 +1.41 +1. I I + + + 0.4 I 0.3 0.3 8 0.5 +1.1 2.4 5.8 2.1 0.9 0.3 3.8 2.3 +0.9 +0.3 +0.1 +0.2 +0.1 +0.1 +0.1 +0.1 + 0.1 +0.1 +0.1 +0.0 +0.0 +0.0 +0.0 0.0 +0.0 +0.0 +0.0 +0.0 0.0 0.0 0.0 +0.0 +0.0 +0.1 +0.1 0.1 +0.1 +0.1 +0.1 PHOTOMETRIC SITE PLAN 1". 20'-0" +0.1 0.2 +0.7 2.3 3.9 1.6 +1 9 +0.1 +0.1 +0.1 +0.1 +0.1 +0.0 +0.0 +0.0 +0.1 +0.1 +5 2 1.8 0.1 \ 0.1 0.1 0.2 0.4 0.5 0.4 0.4 0.4 +0.1 t + +5.1 +3.4 +2.2, +2.1 +2.3 +2.9 +2.7 +2.7 1.0 +0.5 ++ 0.5 0.8 1.2 1.2 +1.1 +1.2 GRAPHIC SCALE 10 0 5 10 20 40 MINI IIIIIIII 111111 (IN FEET ) 1 inch = 20 ft. b1 2.8 +1.3 1 +0.4 0.1 +0.1 +0.1 0.1 +0.0 +0 I + 0.0 i + + 0.0 0.0 + Ji+ + 0 0 I 0.0 0.0 +0.0 0.1 +0.0 +0.0 +0.0 0.0 +0.0 i I RECEWED CITY OF 1 UCWiLA NOV 21 2011 PERMIT CENTER C efecoow.. Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 (/) 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT# A 4eling PRINTED FOR Project Status. • DATE olima ✓ Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from Immo§ authorized project representatives. Issue Date DRAWN BY Designer 0 SHEET Lim PHOTOMETRIC SITE PLAN SHEET NUMBER .ES -2 11/9/2017 5:04:13 PM E D C B A ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION MTG HT AFF TO CL SYMBOL DESCRIPTION MTG HT AFF TO CL LIGHTING FIXTURES MISCELLANEOUS SYMBOLS 2'X4' LAY -IN FIXTURE WITH LED SOURCE -I- GROUND 2'X4' LAY -IN FIXTURE WITH LED SOURCE & EMERGENCY PACK /0/ MOTOR o SURFACE MTD. INCANDESCENT, FLUORESCENT, LED, OR HID LIGHTING FIXTURE MS a MOTION SENSOR -WALL MOUNTED 0 RECESSED INCANDESCENT, FLUORESCENT, LED, OR HID LIGHTING FIXTURE J O JUNCTION BOX (SINGLE GANG STEEL MOUNTED, 4" SQ. STEEL WHERE CEILING MOUNTED, UNLESS NOTED OTHERWISE. WALL MOUNTED LIGHTING FIXTURE, SEE LIGHTING FIXTURE SCHEDULE FLUORESCENT, LED, OR H.I.D. FIXTURE) AS NOTED n CONDUIT AND WIRE 'MARK' NUMBER, REFER TO CONDUCTORS AND CONDUIT SCHEDULE FOR SIZE 11 T b (INCANDESCENT, tet TD WALL MOUNTED EXIT SIGN, SHADING INDICATES FACES. PROVIDE WITH CHEVRON DIRECTIONAL ARROWS WHERE INDICATED ON PLANS PROVIDED WITH BATTERY PACK 6" BELOW CEILING TO TOP (—) KITCHEN EQUIPMENT 'MARK' NUMBER, REFER TO KITCHEN EQUIPMENT SCHEDULE FOR REQUIREMENTS & KITCHEN ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT t®t ® CEILING MOUNTED EXIT SIGN, SHADING INDICATES FACES. PROVIDE WITH CHEVRON DIRECTIONAL ARROWS WHERE INDICATED ON PLANS PROVIDED WITH BATTERY 90 MINUTE PACK 1 O NUMBER KEYNOTE REFERENCE 94r, a,� COMBO EXIT WITH TWO LAMPHEADS, SEE LIGHTING FIXTURE SCHEDULE H A HOOD EXTINGUISHING ANSUL PULL STATION N WALL MOUNTED EMERGENCY BATTERY PACK LIGHTING FIXTURE AS NOTED D SMOKE DETECTORS REMOTE STATUS INDICATOR W/ 1/2" CONDUIT STUB -UP CEILING MOUNTED EMERGENCY BATTERY PACK LIGHTING FIXTURE H ° PUSHBUTTON FLUORESCENT STRIP LIGHTING FIXTURE B 0 BELL, TYPE AS NOTED ON PLANS I I 0 I ® WALLWASHER STYLE RECESSED DOWNLIGHT, AIM LIGHT TOWARD WALL os HO OCCUPANCY SENSOR (WALL OR CEILING MOUNTED) RECESSED LIGHTING FIXTURE WITH EMERGENCY BATTERY PACK ABBREVIATIONS ABBR ABBREVIATION x PENDANT LIGHTING FIXTURE AS NOTED AFF ABOVE FINISHED FLOOR _y___ . LIGHTING TRACK WITH TRACK HEADS AFG ABOVE FINISHED GRADE WIRING DEVICES 120 VOLT DUPLEX RECEPTACLE, 20 AMPS U.O.N. 15" AHU AIR HANDLING UNIT Q I t) 120 VOLT DUPLEX AT SPECIAL MOUNTING HEIGHT, 20 AMPS U.O.N. 44" UON C CONDUIT I 120 VOLT QUADRAPLEX RECEPTACLE, 20 AMPS U.O.N. 15" UON (E) EXISTING ;�;_ 120 VOLT QUADRAPLEX AT SPECIAL MOUNTING HEIGHT, 20 AMPS U.O.N. 44" CL CENTER -LINE ;;;- e, 120 VOLT SIMPLEX RECEPTACLE, 20 AMPS U.O.N. 15" UON EF EXHAUST FAN ® SINGLE SPECIAL PURPOSE RECEPTACLE WITH VOLTS, AMPS, AND PHASE AS NOTED, NEMA CONFIGURATION AS REQUIRED BY EQUIPMENT 15" UON FLA FULL LOAD AMPS GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE(S) MOUNTED ON CORD DROP FROM OVERHEAD ELECTRICAL PANEL, 120 VLT, 20 AMP, U.O.N., OUTLET BOX FLUSH WITH CEILING. GF/GFCI GROUND SINGLE POLE TOGGLE SWITCH 48" GND/GRD HT HEIGHT DOUBLE POLE TOGGLE SWITCH 48" IG ISOLATED GRD, PROVIDE ORANGE DEVICE WHEN ADJACENT TO WIRING DEVICE 3 THREE WAY TOGGLE SWITCH 48" MOCP MAXIMUM OVER CURRENT PROTECTION M MANUAL MOTOR STARTER SWITCH (WP=NEMA 3R) 48" MUA MAKEUP AIR UNIT P SWITCH WITH PILOT LIGHT (ON WHEN SWITCH IS ON) 48" NEC LOCALLY ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NFPA 70) KEY OPERATED SWITCH 48" NL NIGHT LIGHT (ON 24 HOURS) os o OCCUPANCY SENSOR (WALL OR CEILING MOUNTED) 48.. OC ON CENTER NOTE: RECEPTACLES ON A DEDICATED CIRCUIT (THAT IS, NO OTHER LOAD CONNECTED TO THE BRANCH CIRCUIT) SHALL HAVE AMPACITY RATING NOT LESS THAN THE AMPERAGE OF THE CIRCUIT BREAKER SERVING THE DEVICE. POS POINT OF SALE EQUIPMENT PROVIDE FURNISH, INSTALL AND CONNECT CONDUIT/RACEWAYS WITH MINIMUM 2#12, 1#12G, 3/4"C RTU ROOF TOP UNIT �- CONDUIT CONCEALED ABOVE CEILNG OR IN WALL WITH MINIMUM 2#12, 1#12GND-3/4"C III NUMBER OF TICKS DENOTE NUMBER OF PHASE AND GROUNDED (NEUTRAL) TL TWIST LOCK TYPE DEVICE CONDUCTORS (3#12, 1#12GND.-3/4"C.) TR TAMPER-RESISTANT � CIRCUIT HOMERUN TO PANELBOARD WITH MINIMUM 2#12, 1#12GND-3/4"C UON UNLESS OTHERWISE NOTED CONDUIT TURNING UP WP WEATHERPROOF (NEMA 3R) CONDUIT TURNING DOWN COMMUNICATIONS 3 LOW VOLTAGE SYSTEM OUTLET (SEE SPECIFICATIONS, SHEETS E-4.1 & E-4.2) 18" UON iCONDUIT CONCEALED IN OR BELOW SLAB (OUTSIDE =UNDERGROUND) �- FLEXIBLE LIGHT FIXTURE WHIP; SIX FOOT MAXIMUM LENGTH 0 ... 4= COMMUNICATIONS UTILITY BACKBOARD. (3/4" THICK PLYWOOD U.O.N. PER UTILITY COMPANY) AND/OR EQUIPMENT CONNECTIONS, TO COMPLY WITH COMMUNICATIONS COMPANY REQUIREMENTS 60" UON Mc, METAL CLAD CABLE ASSEMBLY - ONLY WHERE INDICATED ON DWGS OR SPECS NOTES: FOR ALL CONDUITS: REFER TO PLANS FOR OTHER CONDUITS, REFER TO VENDOR DRAWINGS FOR CONDUIT AND WIRING REQUIREMENTS FOR LOW VOLTAGE SYSTEMS AND CONTROL WIRING. MULTIPLE 1 PH CIRCUITS MAY OCCUPY THE SAME CONDUIT IN ACCORDANCE WITH THE NEC, MAXIMUM OF THREE AND OF DIFFERENT PHASES. LOW VOLTAGE AND CONTROL WIRING SHALL BE IN SEPARATE CONDUIT FROM POWER WIRING. NOTE: EACH TELEPHONE OUTLET (FLOOR OR WALL MOUNTED)SHALL BE PROVIDED WITH A 3/4" EMPY CONDUIT, WITH PULL WIR, TO ACCESSIBLE CEILING SPACE. CCTV / SECURITY SYSTEM Q. CLOSED CIRCUIT TELEVISION CAMERA I111 SECURITY ALARM KEYPAD 1 DISTRIBUTION EQUIPMENT © SECURITY ALARM HOLD-UP BUTTON zn I NON -FUSIBLE SAFETY SWITCH,SIZE AND TYPE AS NOTED ON PLANS (AMP/POLES/ENCLOSURE) OR N SCHEDULE. NEMA 1 ENCLOSURE UNLESS NOTED WP FOR NEMA 3R ENCLOSURE. 6'-6" * S1 SECURITY SYSTEM KEY NOTE I FUSIBLE SAFETY SWITCH SIZE AND TYPE AS NOTED ON PLANS (AMP/POLES/FUSE AMPS/ENCLOSURE) OR ON SCHEDULE . NEMA 1 ENCLOSURE UNLESS NOTED WP FOR NEMA 3R. 6'-6" ELECTRICAL SITE PLAN UTILITY COMPANY TRANSFORMER, (208 VOLT, 3 PHASE, 4 WIRE SECONDARY) T wisa-mm FLUSH MOUNTED LIGHTING PANELBOARD 6' 6" * SURFACE MOUNTED LIGHTING PANELBOARD 6'-6" * S.P.S.T. LIGHT SWITCH (600V AC QUIET TYPE) TRANSFORMER, PROVIDE SECONDARY GROUNDING PER NEC °GFI DUPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTER ENCLOSED CIRCUIT BREAKER, SIZE AND TYPE AS NOTED (AMPS/POLES/ ENCLOSURE) NEMA 1 ENCLOSURE IF NOT NOTED, WP=NEMA 3R 6-6 „ * ��� / -1 CONDUIT HOMERUN TO PANEL WITH MINIMUM 2#12, 1#12G, 3/4"C * 6'-6" DISTANCE IS TO TOP -MOST DISCONNECTING DEVICE OR HIGHEST POSITION OF OPERATING HANDLE OF DISCONNECTING DEVICE O JUNCTION BOX NEMA 3R (WEATHERPROOF) AS REQUIRED CONDUIT BURIED BELOW GRADE WITH MINIMUM 2#12, 1#12G, 3/4°C POLE MOUNTED SITE LIGHTING FIXTURE. REFER TO CFS ON E-002. SIGNAGE COORDINATION NOTE THE ELECTRICAL SUBCONTRACTOR SHALL INCLUDE THE ELECTRICAL ROUGH -IN AND FINAL CONNECTIONS OF ALL SIGNAGE (BUILDING MOUNTED AND GROUND MOUNTED ON THE SITE) IN HIS SCOPE OF WORK AND UNDER HIS LOCAL CODE PERMITTING PROCESS. PROVIDE A COPY OF THE PERMIT (WHICH SPECIFICALLY INCLUDES THE SIGNAGE) TO THE SIGN VENDOR IN ORDER TO EXPEDITE THE SIGN VENDOR'S PERMIT PROCESS. PROVIDE SCHEDULE 40 PVC CONDUIT(S) FOR TELEPHONE SERVICE FROM UTILITY SOURCE COMMUNICATIONS BACKBOARD WITHIN BUILDING. REFER TO THE ELECTRICAL SITE PLAN (ES -1) FOR ADDITIONAL INFORMATION. BACKFILL, SEE OTHER TRADES FOR REQUIREMENTS FINISHED GRADE 41111J.- 1.241 11• 24" MIN. COORDINATE WITH COMMUNICATIONS UTILITY COMPANY PRIOR TO BID FOR ADDITIONAL OR VARYING REQUIREMENTS NOTE: PROVIDE WARNING TAPE MINIMUM 12" ABOVE TOP OF CONDUITS/ENCASEMENT WITH VERBAGE TO INDICATE UTILITY TYPE BELOW. 3" MINIMUM GRAVEL BACKFILL AROUND CONDUIT(S). REFER TO THE ELECTRICAL SITE PLAN FOR EXACT QUANTITY AND LOCATION(S) OF SERVICE ENTRANCE CONDUITS. COMMUNICATIONS UTILITY COMPANY SERVICE ENTRANCE CONDUITS. SIZED AS FOLLOWS: TELEPHONE/CATV/ISP (4"), AND SPARE (4"). COMMUNICATIONS UTILITY SERVICE CONDUIT DETAIL NOT TO SCALE TERMINATION POINT AS INDICATED ON ELECTRICAL SITE PLAN. HEIGHT OF CONDUIT AT RISER POLE AND METER SHALL BE IN ACCORDANCE WITH THE UTILITY COMPANY REQUIREMENTS. FINISHED GRADE SEE CIVIL PLANS. GROUNDED, RIGID GALVANIZED STEEL CONDUIT. EXTEND CONDUIT UP RISER POLE, OR TO METER OR PANEL 'MDP' ON WALL. TERMINATE CONDUIT AT PANEL, METER, OR RISER POLE AS INDICATED ON ES1. CONDUIT SIZE AND QUANTITY SHALL MATCH UNDERGROUND CONDUIT SIZE AND QUANTITY. TERMINATE WITH WEATHERPROOF CAP FOR EXTENSION AS DIRECTED ON ES1. FITTING LOCATED MINIMUM 18" BELOW FINISHED GRADE OR AS DIRECTED BY THE UTILITY COMPANY. BACKFILL, SEE OTHER TRADES FOR REQUIREMENTS. POW II NOTE: IF CONDUIT IS REQUIRED TO BE TERMINATED ATA PAD MOUNTED TRANSFORMER, INSTALL CONDUIT AT TRANSFORMER IN ACCORDANCE WITH THE UTILITY COMPANY REQUIREMENTS. EXTERIOR CONDUIT TURN UP DETAIL (:).) NOT TO SCALE r. LIGHT FIXTURE PER SCHEDULE - TYPICAL 4'-0" PROVIDE GROUNDED, RIGID GALVANIZED SWEEP "L" SIZE TO MATCH UNDERGROUND CONDUIT SIZE. EXTERIOR UNDERGROUND CONDUIT TO TERMINATION POINT AS INDICATED ON ELECTRICAL SITE PLAN. SEE .ES -1 NOTES FOR ADDITIONAL INFORMATION. 4'-0" FLAG POLE JUNCTION BOX - TYPICAL P4-8" DIA. CONCRETE FOUNDATION - TYPICAL II --— ttn-u. II I I. II: .11=n=—1=11=1=.n= ELEC. CONDUIT - TYPICAL • 4. I- • •• " 5 • , , • a • . 4. • ; t i I. f • I •x •• {, :.I. • • • N •ILS. • - _ _ • •• • . SECTION VIEW 4'-O" LIGHT FIXTURE PER SCHEDULE - TYPICAL 8" DIA. CONCRETE FOUNDATION - TYPICAL _ =11=11=11=u- 4' -O" f . • • PLAN VIEW FLAG POLE ILLUMINATION DETAIL NOT TO SCALE FLAG POLE FLAG POLE COLLAR FLAG POLE FOUNDATION TURN CONDUIT UP IN WALL PVC CONDUIT SHALL EXTEND TO THE FIRST TERMINATION POINT ABOVE THE FLOOR SLAB (NOTE THAT NO PVC SHALL BE IN THE WALL BEHIND EXHAUST HOODS - TRANSITION TO METAL CONDUIT AT FLOOR LINE) FINISHED FLOOR SLAB LONG SWEEP 'L' PVC CONDUIT, SIZE AS INDICATED WALL, REFER TO PLANS INTERIOR PVC CONDUIT DETAIL NOT TO SCALE #4 SOLID BARE COPPER GROUND WIRE FIXTURE OA/OB RE: LUMINAIRE SCHEDULE LIGHT POLE SECT. A -A 3" CLR. TYP. #4 SOLID BARE COPPER GROUND WIRE, BOND TO POLE BASE HAND HOLE WITH CROUND LUG. GROUT LEVELING PAD PER MANUF. RECOMMENDATIONS 1" CHAMFER CORNER (3)#3TIES @ 1 1/2"@TOP ANCHOR BOLTS FURNISHED BY FIXTURE MFR. FINISHED GRADE 1/2" X 8' COPPER CLAD GROUND ROD DRIVEN VERTICALLY 2 CI) 0 Al— 6" CLR.';1 #3 SPIRAL TIES @ 12" O.C. PVC CONDUIT 24" BELOW FINISHED GRADE AS REQUIRED 3" CLR. TYP. 2'-0" DIA. TYPICAL POLE BASE DETAIL (6) # 5 VERTICAL RODS REFER TO STRUCTURAL DRAWINGS FOR EXACT POLE BASE DIMENSIONS NOT TO SCALE BACKFILL, SEE OTHER TRADES FOR REQUIREMENTS SCHEDULE 40 PVC CONDUIT AND CONDUCTORS AS INDICATED ON SINGLE LINE DIAGRAM. SEE SITE PLAN AND SHEETS ES -1 AND E-502 FOR ADDITIONAL INFORMATION. III iii ii iii_ I� ul I I111I I Ill �I 111_1 rr * rr * 'r NOTE: PROVIDE WARNING TAPE MINIMUM 12" ABOVE TOP OF CONDUITS/ENCASEMENT WITH VERBAGE TO INDICATE UTILITY TYPE BELOW. FINISHED GRADE, SEE CIVIL PLANS TOP OF GRAVEL BACKFILL ENCASEMENT SHALL BE 24" BELOW FINISHED GRADE. NOTE: THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY PRIOR TO BID. REFER TO THE ELECTRICAL SITE PLAN FOR ADDITIONAL INFORMATION. ELECTRICAL SERVICE LATERAL CONDUIT DETAIL NOT TO SCALE RECEIVED CITY OF T UKWILA NOV 21 2017 PERMIT CENTER D C B A o l) op:A Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 7O -NEC DEC 13 2017 City of Tukwila BUILDING DIVISION -�' ARCHITECTS PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer dr; Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. 0 SHEET ELECTRICAL SCHEDULES AND DETAILS SHEET NUMBER E-001 11/9/2017 5:04:59 PM 1 2 CONDUIT AND CONDUCTORS SCHEDULE CONDUIT AND CONDUCTORS SCHEDULE Mark No. OCP Device (Amp/P) Load in Amperes Conductors Raceway Size (nominal inches) Phase & Neutral Equip Grd No. Sets Phase, Neutral & Eq Grd With IG Qty Size Type Qty Size EMT IMC RIGID PVC EMT IMC PVC 1 20/1 1 - 16 2 12 THHN 1 12 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 2 20/2 1 - 16 3 12 THHN 1 12 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3 20/3 1 - 16 4 12 THHN 1 12 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 4 25/1 17 - 20 2 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 5 25/2 17 - 20 3 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 6 25/3 17 - 20 4 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 7 30/1 21 - 24 2 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 8 30/2 21 - 24 3 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 9 30/3 21 - 24 4 10 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 10 40/1 25 - 32 2 8 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 11 40/2 25 - 32 3 8 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 3/4 12 40/3 25 - 32 4 8 THHN 1 10 One 3/4 3/4 3/4 3/4 3/4 3/4 1 13 50/1 33 - 40 2 6 THHN 1 10 One 3/4 3/4 3/4 1 1 1 1 14 50/2 33 - 40 3 6 THHN 1 10 One 1 1 1 1 1 1/4 1 1 1/4 15 50/3 33 - 40 4 6 THHN 1 10 One 1 1/4 1 1 1 1/4 1 1/4 1 1/4 1 1/4 16 60/1 41 - 48 2 4 THW 1 8 One 1 1 1 1 1 1/4 1 1 1/4 17 60/2 41 - 48 3 4 THW 1 8 One 1 1/4 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 18 60/3 41 - 48 4 4 THW 1 8 One 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 19 70/1 49 - 56 2 4 THW 1 8 One 1 1 1 1 1 1/4 1 1 1/4 20 70/2 49 - 56 3 4 THW 1 8 One 1 1/4 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 21 70/3 49 - 56 4 4 THW 1 8 One 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 22 80/2 57 - 64 3 3 THW 1 8 One 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 23 80/3 57 - 64 4 3 THW 1 8 One 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 24 90/2 65 - 72 3 2 THW 1 6 One 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/4 1 1/2 25 90/3 65 - 72 4 2 THW 1 6 One 1 1/2 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 26 100/2 73 - 80 3 1 THW 1 6 One 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 27 100/3 73 - 80 4 1 THW 1 6 One 2 2 2 2 2 2 2 28 110/2 81 - 88 3 1 THW 1 6 One 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 29 110/3 81 - 88 4 1 THW 1 6 One 2 2 2 2 2 2 2 30 125/2 89 - 100 3 1 THW 1 6 One 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 31 125/3 89 - 100 4 1 THW 1 6 One 2 2 2 2 2 2 2 32 150/2 101 - 120 3 1/0 THW 1 6 One 2 2 2 2 2 2 2 33 150/3 101 - 120 4 1/0 THW 1 6 One 2 2 2 2 2 2 2 34 175/2 121 - 140 3 2/0 THW 1 6 One 2 2 2 2 2 2 2 35 175/3 121 - 140 4 2/0 THW 1 6 One 2 2 2 2 2 1/2 2 1/2 2 1/2 36 200/2 141 - 160 3 3/0 THW 1 6 One 2 2 2 2 2 1/2 2 1/2 2 1/2 37 200/3 141 - 160 4 3/0 THW 1 6 One 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 38 225/2 161 - 180 3 4/0 THW 1 4 One 2 1/2 2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 39 225/3 161 - 180 4 4/0 THW 1 4 One 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 3 3 40 250/3 181 - 200 4 250 THW 1 4 One 2 1/2 3 3 3 3 3 3 41 300/3 201 - 240 4 350 THW 1 4 One 3 3 3 3 3 3 1/2 3 1/2 42 350/3 241 - 280 4 500 THW 1 3 One 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 4 4 43 400/3 281 - 320 4 3/0 THW 2 3 Two 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 21 /2 44 600/3 321 - 480 4 350 THW 2 1 Two 3 3 3 3 3 3 1/2 3 1/2 45 800/3 481 - 640 4 500 THW 2 1/0 Two 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 4 4 46 1000/3 641 - 800 4 400 THW 3 2/0 Three 3 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 47 1200/3 801 - 960 4 350 THW 4 3/0 Four 3 3 3 3 3 3 1/2 3 1/2 48 1600/3 961 - 1280 4 400 THW 5 4/0 Five 3 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 31 /2 Notes: Conductors are rated at 600 volt or below and are to be copper. NEC Table 310.16 is used for the basis of the conductor ampacities, which is not more than three current carrying conductors in a raceway at an ambient temperature of 30 deg C with 60 deg C rated conductors and connectors per 110.14-C-1 for up to 100 amp rated and up to #1 AWG conductors for equipment terminations and 75 deg C rated conductors and termination connectors for larger than 100 amp or above#1 AWG conductors. NEC Appendix C is used for the basis of the conduit sizes. Table Cl for EMT, Table C4 for IMC, Table C8 for Rigid, and Table C10 for PVC (Sch 40). All Branch Feeders and. Branch Circuits shall include a green Equipment Ground. Omit Grounding conductor on Service Entrance Feeders. Omit Neutral conductor on all Delta primary transformer feeders. The above conductors are not calculated for Voltage Drop. Any circuits that exceed 100 feet shall be calculated by the Installer to have less than a three percent voltage drop on feeders and five percent on branch circuits per the California Electrical Code. NOTE: DO NOT SHARE THE NEUTRAL OR ISOLATED GROUND WIRES OF AN ISOLATED GROUND RECEPTACLE CIRCUIT WITH ANY OTHER CIRCUIT UNLESS IT IS A CIRCUIT SERVING ONLY ISOLATED GROUND RECEPTACLES. 8" METAL STUD WALL ------------- CONDUIT WITH CONDUCTORS IN WALL CONDUCTORS IN THE PIN & SLEEVE'S WIRING AND DEVICE COMPARTMENT (PROVIDE SUFFICIENT SLACK IN CABLES) FRYER'S CORDSET KELLUM SUPPORT BRACKETS TO SUPPORT THE CORDSET RECESSED PIN AND SLEEVE BOX PROVIDED BY THE OWNER'S EXHAUST HOOD SUPPLIER AND INSTALLED BY CONTRACTOR SERVING PIN & SLEEVE BOX DETAIL EXHAUST HOOD RE: MECHANICAL WIRING COMPARTMENT IS ACCESSIBLE VIA THIS DEVICE PLATE KITCHEN NOT TO SCALE ROCKER SELECTOR SWITCHES NOTE: THIS UNIT IS MOUNTED IN THE DOOR OF THE CFA -T500 CONTROL CABINET AND IS INCLUDED WITH THE GEAR ORDER FROM SUNCOAST ENVIRONMENTAL INC. UNOCCUPIED LIGHTING FIXTURE (LUMINAIRE) SCHEDULE - CHICK-FIL-A P12 EDITION NOTE: NOT ALL FIXTURE TYPES ARE USED IN ALL OF THE P12 BUILDINGS. el MARK MANUFACTURER CATALOG NUMBER NO. LAMPS/TYPE WATTS VOLTS MOUNTING REMARKS A LITHONIA 2GTL-472L-A12125V-EZ1-LP840 INTEGRAL WITH FIXTURE 71 120 RECESSED 2'X4' STATIC LED TROFFER RATED 7200 LUMENS, 4000K COLOR TEMP AE LITHONIA 2GTL-472L-A12125V-EZ1-LP840-EL14L INTEGRAL WITH FIXTURE 71 120 RECESSED SAME AS 'A' WITH EMERGENCY BATTERY PACK. SEE PLAN NOTES ABOUT LAMP SWITCHING B1 ILLUMITEX CS1-24-4-DW-6-35-U-WH LED 35 120 SURFACE 24" LONG LED TASK LIGHT, WITH CORD AND PLUG, MOUNTED UNDER SHELVING AS REQUIRED D3 LITHONIA LDN6-30/20-L06AR-120 INTEGRAL WITH FIXTURE 23 120 RECESSED 6" DIA: OPEN 3000°K LED DOWNLIGHT, RATED 2000 LUMENS, WITH CLEAR REFLECTOR AND TRIM RATED D3E LITHONIA LDN6-30/20-L06AR-120-EL INTEGRAL WITH FIXTURE 23 120 RECESSED SAME AS FIXTURE TYPE 'D3' EXCEPT WITH EMERGENCY BATTERY PACK AND INTEGRAL TEST SWITCH D4 LITHONIA LDN6-30/20-LW6AR-120 INTEGRAL WITH FIXTURE 35 120 RECESSED SAME AS D3 EXCEPT WITH WALLWASH REFLECTOR TRIM F MEYDA 30894-8 (144638) 1-SATS9238 12 120 CEILING EGG LIGHT FURNISHED WITH A 12 WATT A19-GU24 LED LAMP G1 LITHONIA ZLIN L48 5000LM FST MVOLT 35K WH LED 41 120 WALL LED STRIP FIXTURE MOUNTED ABOVE DOOR FRAME J LITHONIA ZLIN L48 5000LM FST MVOLT 35K WH LED 41 120 WALL LED STRIP FIXTURE MOUNTED IN SERVICE AREA L LITHONIA VSL-232-MVOLT-DL-GEB10IS 2-(GE)F28T8/XUSPP35/ECO 50 120 SURFACE LOW PROFILE DAMP LOCATION FLUORESCENT. MS LEVITON PS110-10W N/A 4 120 WALL MOTION SENSOR ON FLUSH BACKBOX, PROVIDE COVERPLATE W/ CENTER THREADED KNOCKOUT N MINKA 4531-267B 1-CF19EUMINI-TWIST/2700 19 120 WALL "COW BELL" LAVATORY WALL SCONCE WITH SHADE POINTED DOWN P1 MEYDA 142776 2-LED11A19/827/D 22 120 PENDANT 31" DIA PEACH BASKET PENDANT WITH BTM AT 6'-3" AFF ABV TABLE, 7'-6" OTHERWISE P2 MEYDA 142777 1-LED11A19/827/D 11 120 PENDANT 20" DIA PEACH BASKET PENDANT WITH BTM AT 6'-3" AFF ABV TABLE, 7'-6" OTHERWISE Q TROY KF14856-1-NL - - - PENDANT NON -ILLUMINATED CUSTOM 48"X12"X12" COCA-COLA BOTTLE PENDANT, BTM AT 6'-3" AFF. REQUIRES 2 CLG J -BOXES FOR MTG. U BESA LIGHTING BES00298-060 FURNISHED 7.5 120 PENDANT RED FRIT GLASS, BRONZE CABLE & CANOPY, 6'-6" AFF V VISUAL COMFORT SL2923BZ 1-BULLED11A19/827/D 11 120 WALL BOSTON LIBRARY LIGHT, MOUNT BACKBOX AT 7'-2" AFF W/ 11 WATT A19 LED LAMP XA LITHONIA LHQM-S-W-1-R-120 LED 4 120 WALL EXIT SIGN WITH BATTERY PACK AND TWO INTEGRAL ADJUSTABLE LAMPHEADS XC LITHONIA AFN-BN-EXT (TWO LAMP UNIT) LED 21 120 WALL EXTERIOR WALL MOUNTED EMERGENCY LIGHTING UNIT, LOCATE NEAR EGRESS DOOR XD DUAL -LITE LG2S NONE 250 120 WALL INVERTER UNIT FOR EXTERIOR EGRESS LTG; ON AT DUSK, OFF AT DAWN, ON DURING PWR OUTAGE OA LITHONIA DSX0-LED-40C-1000-30K-TFTM-MVOLT-HS 40-3000°K LEDS @1000MA 138 120 POLE POLE (25'-0") MOUNTED LED AREA LUMINAIRE W/ 2'-0" HIGH POLE BASE (SEE 2/ES-3) WITH HOUSE SIDE SHIELD OB LITHONIA DSX0-LED-40C-1000-30K-TFTM-MVOLT-HS (2)40-3000°K LEDS @1000MA 276 120 POLE DUAL POLE (25'-0") MOUNTED LED AREA LUMINAIRE W/ 2'-0" HIGH POLE BASE (SEE 2/ES-3) WITH HOUSE SIDE SHIELD OE PROGRESS LIGHTING P5675-31 WITH P8799 TOP COVER LENS 2-(GE)LED12P30RW83025 24 120 WALL 5" DIAMETER, 14" HEIGHT, WET LOCATION, UP/DOWN CYLINDER W/ 12 WATT PAR30 3K NFL LED LAMPS OG PHILIPS EW BLACK 21 DEGREE (523-000069-11) 2700°K 1 -LED 50 120 GRADE EXTERIOR LED FIXTURE MOUNTED AT GRADE AT FLAGPOLE. SEE DETAIL 6 ON SHEET E-001 OK BEGA 2383LED LED 26 120 WALL EXTERIOR WALL MOUNTED LED SECURITY LIGHT MOUNTED AT +8'-0" FF. IN SERVICE AREA NOTES: 1. LUMINAIRES UTILIZING DOUBLE -ENDED LAMPS AND CONTAIN BALLASTS THAT CAN BE SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS EITHER INTERNAL OF EXTERNAL TO EACH LUMINAIRE PER NEC 410.130(G). 2. THE LIGHTING FIXTURE PACKAGE IS AVAILABLE THROUGH A NATIONAL ACCOUNT PROGRAM. REFER TO THE ELECTRICAL SPECIFICATIONS SHEET, SECTION C16500 FOR VENDOR INFORMATION. * 3. THE ASTERIK (*) BESIDE THE FIXTURE MARK IN THE ABOVE SCHEDULE INDICATES THE FIXTURE ISA NON -PROTOTYPICAL LIGHT FIXTURE PER THE CFA NATIONAL P12 PROTOTYPE. ROCKER SELECTOR SWITCHES NOTE: THIS UNIT IS MOUNTED IN THE DOOR OF THE CFA -T500 CONTROL CABINET AND IS INCLUDED WITH THE GEAR ORDER FROM SUNCOAST ENVIRONMENTAL INC. UNOCCUPIED OCCUPIED ' 120 VOLT COIL OVERRIDE (ON) AUTO OFF OVERRIDE (ON) AUTO ' 120 VOLT COIL • (STORE SWITCH ON AND OFF) . ' 30A 4 -POLE CONTACTOR -3 ' 30A 4 -POLE • ON AND OFF) STORE SWITCH SIGNAGE & BUILDING PARKING LOT POLE LIGHTS SYSTEM ON AIR CONDITIONING STATUS GREEN AND RED 0 PILOT LIGHTS NIGHT SET BACK STORE OPEN -CLOSED SWITCH CONTROL UNIT NOT TO SCALE MAINTAIN ELECTRICAL CONTINUITY BETWEEN METAL BOX AND OUTLET PROVIDE PLASTER RING AND FACEPLATE BLACK/RED/BLUE WHITE GREEN/YELLOW STRIPE GREEN NOTE: 1. THE ISOLATED GROUND CONDUCTOR SHALL ORIGINATE AT THE ISOLATED GROUND BAR OF PANEL POS. 2. ALL RECEPTACLES SHALL BE PIGTAILED. FEED THROUGH OF BRANCH CIRCUIT WIRING, THROUGH RECEPTACLE DEVICE, SHALL NOT BE PERMITTED. I.G. RECEPTACLE GROUNDING DETAIL NOTE: GROUNDING CONDUCTOR SHALL BE CONTINUOUS SO THAT REMOVAL OF DEVICE WILL NOT INTERFERE WITH CONDUCTOR CONTINUITY. WIRE NUT WIRE CONNECTORS GROUNDING SCREW IN TAPPED HOLE IN BOX METAL OUTLET BOX PROVIDE WIRE NUT ON PHASE CONDUCTOR WHERE CONDUCTOR IS CUT NOT TO SCALE CIR C-1 CIRC -3 CIRC -5 CIR C-11 CIR C-7 CIR C-9 CIR C-15 SPARE CIRC -2 CIR C-4 CIR C-6 CIR C-40 CIR C-19 CIR C-39 CIR C-41 CIR C-43 SPARE CIR C-20 CIR C-24 SPARE 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SWITCHED LEG TO FIXTURES NOTED AS CONTROLLED BY SWITCH AT SWITCHBANK (SB) SWITCHED LEG TO FIXTURES NOTED AS CONTROLLED BY THE CONTACTOR (CONT) NON -SWITCHED LEG TO EM BATTERY PACKS AND FIXTURES NOTED AS NIGHT LIGHTS (NL) w w—� 120V FROM PANELBOARD BK BK S.P.S.T. SWITCH AT SWITCHBANK – – – BK— LIGHTING CONTROL DIAGRAM BK -4 LIGHTING CONTACTOR IN CFA -T500 CONTROL PANEL NOT TO SCALE CONTACTOR -1 30A 4 -POLE ' 120 VOLT COIL • (STORE SWITCH ON AND OFF) . CONTACTOR -2 ' 30A 4 -POLE ' 120 VOLT COIL • (STORE SWITCH ON AND OFF) . ' 30A 4 -POLE CONTACTOR -3 ' 30A 4 -POLE ' 120 VOLT COIL ON AND OFF) (P'CELL ON AND SWITCH OFF) CONTACTOR -9 CONTACTOR -4 30A 4 -POLE ' 120 VOLT COIL (PHOTOCELL ON . (P'CELL ON AND • SWITCH OFF) ' CONTACTOR -10 CONTACTOR -5 30A 4 -POLE ' 120 VOLT COIL ' (SWITCH ON & • (P'CELL ON AND • SWITCH OFF) . 0 0 0 0 '0 '0 '0 0 0 0 0 0 0 0 0 '0 '0 '0 '0 KITCHEN LTG KITCHEN LTG RESTROOM LTG DINING LTG DINING LTG PLAY & SERV AREA LTG WATER RECIRC PUMP SPARE BLDG. SIGNAGE BLDG. SIGNAGE BLDG. SIGNAGE SPARE DIRECTIONAL SIGNS MONUMENT SIGN MONUMENT SIGN MONUMENT SIGN SPARE BLDG LIGHTING BLDG LIGHTING SPARE NOTES: 1) VERIFY WITH SUNCOAST ENVIRONMENTAL CONTROLS' SHOP DRAWINGS. 2) ONLY THE 'HOT' CONDUCTOR OF EACH CIRCUIT SHALL BE RUN THRU THE CONTACTOR. 3) ANY TAPS OR WIRING CONNECTIONS OTHER THAN TO THE TERMINALS SHALL BE DONE IN A JUNCTION BOX OUTSIDE OF THIS CABINET. 4) VERIFY WITH THE LOCAL CODE IF CONTACTORS #10 AND #11 WILL BE ON OR OFF WHEN THE ANSUL SYSTEM IS INITIATED. T-500 CONTROL PANEL CONNECTION DIAGRAM SPARE SPARE SPARE SPARE CIR C-21 CIR C-23 CIR C-25 SPARE SPARE SPARE SPARE SPARE CIR C-12 SPARE SPARE SPARE CIR A-36 CIR A-38 SPARE SPARE CIR A-41 SPARE SPARE SPARE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CONTACTOR -6 ' 30A 4 -POLE ' 120 VOLT COIL • (P'CELL ON AND SWITCH OFF) . CONTACTOR -7 ' 30A 4 -POLE ' 120 VOLT COIL • (P'CELL ON AND SWITCH OFF) ' CONTACTOR -8 ' 30A 4 -POLE ' 120 VOLT COIL • (STORE SWITCH ON AND OFF) ' CONTACTOR -9 30A 4 -POLE ' 120 VOLT COIL ' (PHOTOCELL ON . AND OFF) . CONTACTOR -10 30A 4 -POLE ' ' 120 VOLT COIL (SWITCH ON & • OFF, ANSUL ON) . CONTACTOR -11 30A 4 -POLE ' 120 VOLT COIL (SWITCH ON & • OFF, ANSUL ON) . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SPARE SPARE SPARE SPARE NOTE: LOCATIONS WITH TWO MAIN ID SIGNS WILL USE THIS CONTACTOR FOR THE SECOND SIGN. PARKING LOT LTG. PARKING LOT LTG. PARKING LOT LTG. SPARE SPARE SPARE SPARE SPARE NOTE: LOCATIONS WHERE TASK LIGHTS ARE TO BE CONTROLLED (IECC 2012) SHALL USE THIS CONTACTOR SECURITY/FLAG LTG SPARE SPARE SPARE EXHAUST FAN EF -1 EXHAUST FAN EF -2 SPARE SPARE CAPTURE JET (CJ) FAN SPARE SPARE SPARE RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER NOT TO SCALE D C • efetA Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 oo co239) cdM e v s o o co f4,3 0 co V♦ ~ r FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED. FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # A15PRINTED FOR DATE cn v a) Project Status Issue Date DRAWN BY Designer Information contained on this drawing and in all digital riles produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. 0 SHEET Am LIGHTING AND POWER 0. PLAN KEYNOTES SHEET NUMBER E-002 11/9/2017 5:05:37 PM E D C B A 4 P12 VERIFY THE QUANTITY AND ROUGH -IN OF EACH EQUIPMENT ITEM WITH THE KITCHEN EQUIPMENT SCHEDULE ON SHEETS K2.1 AND K2.2 SCHEDULE NOTES EQUIP. NO. BLDG TYPE EQUIPMENT DESCRIPTION ELECTRICAL LOAD NEMA CONFIG COOPER/ARROW HART (UON) RECEP CATATOG NO. Wire/Conduit MARK NO. COMMENTS AND REMARKS VOLTS PH WIRES KW AMPS LS LE LC SE 120 X X X X HOT HOLDING CL TABLE 208 3 4 5.040 22/12.5/7.5 DIRECT - 18 LISTED LOAD INCLUDES PLUG-IN ITEMS 120a X X X X COLD CL TABLE 208 3 4 3.280 6.5/13.3/7.83 DIRECT - 18 LISTED LOAD INCLUDES PLUG-IN ITEMS 120c X X X X TOASTER CL TABLE 208 3 4 18.600 56.6/41.6/56.6 DIRECT - 18 LISTED LOAD INCLUDES PLUG-IN ITEMS 120d X X X X CL UNDERCOUNTER REFRIG 120 1 2 0.580 5.0 N/A FURNISHED IN #120a - 500A X X X X VERTICAL CONTACT TOASTER 120 1 2 1.800 15.0 N/A FURNISHED IN #120c - 500B X X X X RADIANT TOASTER 208 1 3 5.000 24.0 N/A FURNISHED IN #120c - 550 X X X X DOUBLE WARMING DRAWER 120 1 2 0.900 7.83 N/A FURNISHED IN #120 - 564 X X X X PRODUCT HOLDING CABINET 120 1 2 1.600 13.3 N/A FURNISHED IN #120a - 180 X X X X ORDER REGISTER (POS) 120 1 2 0.7 5-20R IG5362RN (ORANGE) 1 -IG 182 X X X X RECEIPT PRINTER 120 1 2 0.18 5-20R IG5362RN (ORANGE) 1 -IG NOTE 5 183 X X X X ORDER MONITOR 120 1 2 0.125 5-20R IG5362RN (ORANGE) 1 -IG NOTE 2 OR 5 184 X X X X IPAD 120 1 2 0.120 1.0 5-20R VGF20 1 NOTE 2 190 X X X X DRIVE-THRU VIDEO MONITOR 120 1 2 0.8 5-20R CR20 1 NOTE 5 211b X X X X FLY SYSTEM - KITCHEN AREA 120 1 2 0.078 0.650 5-15R TR780W (DUPLEX) 1 CLOCK STYLE RECEPTACLE REQ'D 211c X X X X FLY SYSTEM - DINING AREA 120 1 2 0.030 0.25 5-15R TR780W (DUPLEX) 1 CLOCK STYLE RECEPTACLE REQ'D 269 X X X X ANSUL FIRE SYSTEM 120 1 2 VERIFY DIRECT - 1 FED FROM THE LC&D CONTROL SYSTEM 270 X X X X ANSUL FIRE SYSTEM 120 1 2 VERIFY DIRECT - 1 FED FROM THE LC&D CONTROL SYSTEM NOTE 2 300a X X X X MILKSHAKE DISPENSER 120 1 2 4.0 5-20R 1877 (SIMPLEX) 1 300X X X X X DOUBLE BARREL ICE DREAM 208 3 3 15.0 15-20R HUBBELL HBL8420 2 FURNISHED WITH ANGLE PLUG 208 3 3 19.0 15-30R HUBBELL HBL8430A 8 FURNISHED WITH ANGLE PLUG NOTE 2 305 X X X X TEA BREWER 120 1 2 1.650 13.8 5-20R VGF20 1 308 X X X X COFFEE BREWER 208 1 3 4.000 19.2 L14 -30R CWL143OR 8 308d X X X X DRY & DAIRY DISPENSER 120 1 2 1.0 5-20R CR20 1 NOTE 2 310 X X X X DOUBLE JUICE DISPENSER 120 1 2 8.2 5-20R 1877 (SIMPLEX) 1 315W X X X X DRINK TOWER 120 1 2 10.0 5-20R CR20 1 NOTE 2 320 X X X X TURBO CARBONATOR 120 1 2 6.2 5-20R CR20 1 380A X X X X ICE BIN SANITATION SYSTEM 120 1 2 0.010 5-15R - - PLUGS INTO DUPLEX OF ONE #380Z UNIT NOTE 5 380Z X X X X INTERIOR ICE MAKER 120 1 2 6.0 5-15R 817 (SIMPLEX) CR15 (DUPLEX) 1 380ZC X X X X ROOF MTD ICE CONDENSER 208 3 4 21.2 DIRECT - 12 NOTE 2 400 X X X X REACH -IN FRY FREEZER 120 1 2 9.4 5-20R VGF20 1 NOTE 5 401 - - - - 48" FRY FREEZER WORK TABLE 120 1 2 8.7 L5 -20R CWL52OR 1 PROVIDE TWIST LOCK PLUG IN FIELD NOTE 5 402 X - - X 60" FRY FREEZER WORK TABLE 120 1 2 8.7 L5 -20R CWL52OR 1 PROVIDE TWIST LOCK PLUG IN FIELD 410 X X X X WALK-IN FREEZER DOOR HTR/LTG 120 1 2 3.3 DIRECT - 1 REFER TO LIGHTING FLOOR PLAN 410a X X X X WI FREEZER CONDENSER 208 3 3 14.38 DIRECT - 8 410b X X X X WI FREEZER EVAP COIL 208 1 2 1.5 DIRECT - 1 POWER FED FROM CONDENSER NOTE 5 420 X X X X SINGLE UC REFRIGERATOR 120 1 2 4.7 5-20R 1877 (SIMPLEX) 1 NOTE 2 421 X X X X DOUBLE UC REFRIGERATOR 120 1 2 6.3 5-20R 1877 (SIMPLEX) 1 NOTE 2 431 X X X X REFRIGERATED WORK TABLE 120 1 2 6.3 5-20R 1877 (SIMPLEX) 1 NOTE 5 432 X X X X REFRIGERATED WORK TABLE 120 1 2 6.3 L5 -20R CWL52OR 1 PROVIDE TWIST LOCK PLUG IN FIELD NOTE 2 440 X X X X BREADING TABLE 120 1 2 12.0 (L)5 -20R CWL52OR / VGF20 1 NOTE 5 441 X X X X REFRIGERATED SALAD PREP 120 1 2 9.0 L5 -15R CWL515C / CWL515R 1 15 AMP TWIST LOCK PLUG PROVIDED W/ EQUIP 444 X X X X DOUBLE DOOR THAWING CABINET 120 1 2 16.0 DIRECT - 1 PROVIDE 6 FT LIQUID -TIGHT FLEX CONDUIT 444S - - - - SINGLE DOOR THAWING CABINET 120 1 2 16.0 DIRECT - 1 449 X X X X WALK-IN COOLER LIGHTING 120 1 2 2.4 DIRECT - 1 REFER TO LIGHTING FLOOR PLAN 449a X X X X WI COOLER CONDENSER 208 3 3 5.75 DIRECT - 3 449b X X X X WI COOLER EVAP COIL 208 1 2 1.0 DIRECT - 1 POWER FED FROM CONDENSER 505 X X X X CONVECTION OVEN 208 3 3 5.600 24/12/15 15-30R AH8430N 9 PROVIDE ANGLE PLUG ON CORDSET 505G X X X X GRIDDLE TOP CONVECTION OVEN 208 3 3 19.800 57.6 15-60R AH8460N 17 PROVIDE 6 FT CORD AND ANGLE PLUG 521 X X X X WARMING EYES 208 1 3 3.900 18.8 6-30R 5700N 8 PROVIDE 6 FT CORD AND PLUG NOTE 3 522 X X X X OPEN FRYER - ELECTRIC 208 3 3 22.000 61.0 NOTE 3 - 22 PLUG AND CORD -SET PROVIDED W/ EQUIP NOTE 3 522A X X X X DOUBLE OPEN FRYER - REQUIRES TWO ELECTRICAL CONNECTIONS EACH OF THE SAME LOAD AND CHARACTERISTICS AS #522 ABOVE 523 X X X X PRESSURE FRYER - ELECTRIC 208 3 3 13.500 38.0 15-50R HUBBELL HBL8450A 14 PLUG AND CORD -SET PROVIDED W/ EQUIP 524 X X x x DUAL SIDED CHAR -GRILL 208 3 3 16.050 43.4/43.4/47 15-50R HUBBELL HBL8450A 14 NOTE 2 560 X X X X FRY HOLDING STATION 120 1 2 1.840 15.4 5-20R 1877 (SIMPLEX) 1 NOTE 5 563D X X X X DOUBLE SANDWICH SLIDE 120 1 2 1.090 9.13 5-20R 1877 (SIMPLEX) 1 NOTE 5 563S X X X X SINGLE SANDWICH SLIDE 120 1 2 0.548 4.56 5-20R 1877 (SIMPLEX) 1 NOTE 2 565C X X X X FOOD COOKER/WARMER 120 1 2 1.500 12.50 5-20R VGF20 1 580 X X X X MULTI -USE HOLDING CABINET 120 1 2 2.880 24.0 L5 -30R CWL53OR 7 NOTE 5 600 X X X X MIXER 120 1 2 8.0 L5 -20R CWL52OR 1 PROVIDE TWIST LOCK PLUG IN FIELD NOTE 5 601 X X X X NOT USED - - - - - - - - NOTE 2 607 X X X X COUNTER TOP LEMON JUICER 120 1 2 0.25 5-15R VGF20 1 PROVIDE GFCI DUPLEX RECEPTACLE 669 X X X X OFFICE SAFE (SMART SAFE) 120 1 2 5-20R CR20 1 NOTE 2 671 X X X X SMALL MENU BOARD 120 1 2 0.054 0.45 5-20R CR20 1 WIRING DEVICE PACKAGE, INCLUDING SWITCHES (EXCEPT HUBBELL BRAND DEVICES) SHALL BE PURCHASED AS A PART OF A NATIONAL ACCOUNTS PROGRAM THROUGH GEXPRO (FORMERLY GE SUPPLY). CONTACT BRIAN REECE AT 770-840-4162 (EMAIL: BRIAN.REECE@GEXPRO.COM) NOTE 1: ALL SO CORD LENGTHS SHALL BE MEASURED FROM THE REAR OF THE EQUIPMENT TO THE END OF THE CORD. NOTE 2: CONTRACTOR SHALL PROVIDE GROUND -FAULT PROTECTION FOR ALL 120 VOLT 15 AMP AND 20 AMP RECEPTACLES IN THE KITCHEN / FOOD PREPARATION AREAS. GROUND -FAULT PROTECTION SHALL BE PROVIDED AT THE RECEPTACLE AS A GFCI TYPE RECEPTACLE UNLESS NOTED OTHERWISE ON THE PLANS WHERE A GFCI TYPE BREAKER IS INDICATED. A RECESSED PIN & SLEEVE BOX IS PROVIDED WITH THE EXHAUST HOOD PACKAGE AND INSTALLED BY THE CONTRACTOR. THE P&S BOX INCLUDES THE "SLEEVE" RECEPTACLES FOR THE OPEN FRYERS. THE OPEN FRYER SUPPLIER WILL PROVIDE PRE -WIRED CORDSET WITH NOTE 3: A "PIN"DEVICE INTEGRAL WITH THE OPEN FRYER TO PLUG INTO THE "SLEEVE"RECEPTACLE. NOTE 4: WIRE NUMBER INDICATED DOES NOT INCLUDE THE REQUIRED GREEN EQUIPMENT GROUND CONDUCTOR OR, WHEN APPLICABLE, THE STRIPED IG CONDUCTOR. NOTE 5: PROVIDE GFCI TYPE BRANCH BREAKER FOR KITCHEN/FOOD PREPARATION AREA RECEPTACLES THAT ARE TWIST -LOCK, CLOCK STYLE, OR IG (ISOLATED GROUND) TYPE. NOTE 6: REFER TO THE CONDUIT AND CONDUCTOR SCHEDULE FOR THE WIRE/CONDUIT MARK NUMBER AND THE MINIMUM WIRE AND CONDUIT SIZE FOR EACH EQUIPMENT ITEM. NEMA 5-15 NEMA 5-20 NEMA L5-20 NEMA L6-30 NEMA L14-20 NEMA 14-30 NEMA L14-30 NEMA 15-20 NEMA 15-30 NEMA 15-50 NEMA 15-60 EQUIPMENT ITEM'S ELECTRICAL CORD TO BE CONNECTED TO THE BELL BOX MOUNTED ON THE TOP -REAR OF THE ITEM ---\ COOPER #S2983 NON-METALLIC WEATHER - PROOF TYPE SWITCH COVER (TO REDUCE ADDICENTAL BUMPING AND TURNING POWER OFF) WITH SPEC GRADE SWITCH BEHIND COVER (SEE SECTION 16141 IN THE ELECTRICAL SPECIFICATIONS) FLEXIBLE CONDUIT ELBOW CONNECTOR SURFACE MOUNTED SINGLE GANG BELL BOX MOUNTED TO THE TOP -REAR OF THE EQUIPMENT ITEM AT THE POINT OF THE POWER CONNECTION FLEXIBLE LIQUID -TIGHT METAL CONDUIT FROM OEP DROP CORD BOX FLUSH IN CEILING BOX TO THE KITCHEN EQUIPMENT ITEM (FIELD VERIFY LENGTH OF FLEX CONDUIT REQUIRED) - DIRECT CONNECTION -ISLAND LOCATION NOT TO SCALE EMT CONDUIT WITHIN WALL CAVITY WITH 90 DEGREE BEND AND THREADED FITTING THRU WALL FINISH TO ATTACH TO BACK OF BELL BOX SURFACE MOUNTED SINGLE GANG BELL BOX COOPER #S2983 NON-METALLIC WEATHER -PROOF TYPE SWITCH COVER (TO REDUCE ADDICENTAL BUMPING AND TURNING POWER OFF) WITH SPEC GRADE SWITCH BEHIND COVER (SEE SECTION 16141 IN THE ELECTRICAL SPECIFICATIONS.) FLEXIBLE CONDUIT CONNECTOR 6 FOOT FLEXIBLE LIQUID -TIGHT METAL CONDUIT FROM SURFACE BOX TO THE KITCHEN EQUIPMENT ITEM. (THE CORDSET PROVIDED WITHT THE EQUIPMENT ITEM MUST BE REMOVED. THE CORD CANNOT BE USED FOR THE DIRECT CONNECTION PER NEC 400.7(B) WHICH REQUIRES A CORD TO BE EQUIPPED WITH AN ATTATCHMENT PLUG AND ENERGIZED FROM THE RECEPTACLE OUTLET) FLEXIBLE CONDUIT ELBOW CONNECTOR EQUIPMENT ITEM'S ELECTRICAL CORD TO BE CONNECTED TO THE BELL BOX MOUNTED ON THE TOP -REAR OF THE ITEM SURFACE MOUNTED SINGLE GANG BELL BOX MOUNTED TO THE TOP - REAR OF THE EQUIPMENT ITEM AT THE POINT OF THE POWER CONNECTION WITH BLANK COVER DIRECT CONNECTION - WALL LOCATION NOT TO SCALE HOOD#3 ANSUL SYSTEM 1 CONTROL PANEL fel MICROSWITCH #1 MICROSWITCH #2 HOOD#1 ANSUL SYSTEM CONTROL PANEL -_J MICROSWITCH #1 IN.O. N.C. 1'- 1'li-e-1 MICROSWITCH #2 --J BROWN MICROSWITCH #3 BLACK 1 NOTE: THE CFA T-500 CONTROL PANEL IS POWERED FROM CIRCUIT B-36. RED CFA T-500 CONTROL PANEL OJ BROWN MICROSWITCH #3 BLACK [N.O. MICROSWITCH #4 BLACK RED FICO. ---J MICROSWITCH #4 RED BLACK 5a SNAP -ACTION SWITCHES ARE SHOWN IN THE ARMED POSITION (TYP OF FOUR) ANSUL SYSTEM PANEL WIRING DIAGRAM NOT TO SCALE 4a FIRE INTERLOCK FIRE INTERLOCK FIRE INTERLOCK 1 120 VOLT CONTROL LOOP, SEE KITCHEN POWER PLAN FOR ADDITIONAL INFORMATION TO SHUNT -TRIP BREAKER IN PANEL -MDP FOR EQUIPMENT LOCATED UNDER THE EXHAUST HOODS. RECEIVE -70 CITY OF T UKWIL: NOV 21 2017 PERMIT CENTER E OAP D C B A tap V 0) CfgA Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 u_ 1 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC DEC 132017 City of Tukwila BUILDING,DIVISICI ARCHITECTS PROJECT # I'll" PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ® SHEET ELECTRICAL SCHEDULES AND DETAILS SHEET NUMBER E-003 11/9/2017 5:06:19 PM 2#10, 3/4"C FROM THE LC&D CONTROL SYSTEM (ON WHEN STORE IS OCCUPIED, OFF WHEN STORE IS UNOCCUPIED) VIA CIRCUIT C-38. H 120V EQ GROUND CONDUCTOR NOT SHOWN, BUT REQ'D OPEN ✓o OFF CLOSED THREE POSITION SP -DT SWITCH FURNISHED BY THE CANOPY SUPPLIER AND (STALLED BY THE CONTRACTOR. OPEN 00 OFF CANOPY LIGHTS (70 WATTS) MENUBOARD (58 WATTS) 'OPEN' SIGN • (4 WATTS) • / 'CLOSED' ` SIGN (4 WATTS) DRIVE THRU LANE #2 ;M • CANOPY LIGHTS (70 WATTS) MENUBOARD 'OPEN' SIGN / • (4 WATTS) CLOSED I 'CLOSED' / SIGN (4 WATTS) S VIDEO SCREEN/CAMERA DRIVE THRU LANE #1 VIDEO SCREEN/CAMERA MULTI -LANE DRIVE-THRU ORDER AREA CANOPY POWER WIRING SCHEMATIC NOT TO SCALE DT1 D 2T THE DT LANE CONTROL SWITCH TO BE LOCATED AT THE MLOP ORDERING STATION FOR CONTROL OF THE DT LANES. IF MULTI -LANE ORDERING WILL NOT BE INCORPORATED INTO THE PROJECT, A DOUBLE GANG BACKBOX WITH EMPTY CONDUIT AND A BLANK COVER PLATE ARE TO BE PROVIDED FOR FUTURE USE. GREEN INDICATOR LIGHT THREE POSITION SP -DT SWITCH & PLATE FURNISHED BY THE CANOPY SUPPLIER AND INSTALLED BY THE CONTRACTOR. PROVIDE LABELS ON SWITCH PLATE RED INDICATOR LIGHT 3 POSITION DT LANE CONTROL STATION NOT TO SCALE MULTI -LANE ORDER POINT (MLOP) DRIVE-THRU REQUIREMENTS DT SERVING AREA RETROFIT STYLE DOUBLE - GANG RING (CARLON #SC200RR) WITH CONDUIT TERMINATING AT THE RING IN THE WALL (TYP) DETAIL KEY NOTES: 1" EMPTY UNDERGROUND SCH40 PVC CONDUIT FOR OWNER'S AUDIO SYSTEM/DETECTOR LOOP CABLES. 2" UNDERGROUND SCH40 PVC CONDUIT FOR POWER CIRCUITS, SEE POWER WIRING SCHEMATIC. MLOP CONTROL STATION 2" CONDUIT STUBBED UP INTO THE CEILING SPACE SEE SHEET E2.2 FOR THIS KEYNOTE AND DESCRIPTION (TYP) SEE POWER WIRING DIAGRAM FOR WIRING REQUIREMENTS IN THE UNDERGROUND ELEC CONDUIT IN -GROUND PULLBOX EQUIVALENT TO QUAZITE 2" EMPTY UNDERGROUND SCH40 PVC CONDUIT FOR OWNER'S AUDIO SYSTEM/DETECTOR LOOP CABLES. J DT #2 CANOPY AND MENUBOARD, REFER TO SITE PLAN FOR LOCATION -b -b DT #1 CANOPY AND MENUBOARD, REFER TO SITE PLAN ES -1 FOR LOCATION MULTI -LANE DRIVE-THRU ORDER AREA CONDUIT REQUIREMENTS NOT TO SCALE PROVIDE A KNOCKOUT IN THE TOP OF THE 10"X8" BOX ANDA HOLE IN THE WALL'S TOP PLATE FOR THE HME UNIT'S ANTENNAE SURFACE MOUNTED DEVICE BOX ON LEFT SIDE OF 10"X8" BOX WITH A 120V, 20A DUPLEX RECEPTACLE OUTLET AND DEVICE PLATE FLUSH MOUNTED 4" DEEP, 10" WIDE, 8" HIGH STEEL BOX WITH 2" HIGH CUSTOM COVER PLATE FOR MOUNTING OF THE HME UNIT OVER THE BOX _J Ir II EQ I i.) II it I i/ o HME UNIT'S POWER & DATA BOX DETAIL NOT TO SCALE 2"Xl 0" CUSTOM COVER PLATE ATTACHED AT THE TOP OF THE BACKBOX WITH TWO SCREWS. PROVIDE TWO ADDITIONAL SCREWS AT 8" APART FOR THE HME UNIT'S REAR MOUNTING SLOTS TO ATTACH OVER THE 10"X8" BACKBOX. SURFACE MOUNTED DEVICE BOX ON RIGHT SIDE OF 10"X8" BOX WITH AN EMPTY 3/4" CONDUIT STUBBED UP INTO THE CEILING SPACE FOR OWNER'S DATA CABLES. (NOTED AS KEYNOTE 'C2' ON SHEET E-221) RECEIVE -70 CITY OF TUKWILA NOV 21 2017 PERMIT CENTER D C 01•0 w cgs, Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 1 0 B v 0 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION cn ARCHITECT'S PROJECT # ##### ACO CO co PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer • Information contained on this drawing and in all digital files W produced for above named project may not be reproduced in any manner without express written or verbal consent from II ■ _ authorized project representatives. O SHEET 21. DT ORDERING AREA DETAILS AND REFUSE ENCLOSURE PLAN SHEET NUMBER E-004 11/9/2017 5:07:05 PM E D OE S 20 C B A QC -6 3 - : AT MAIN I O CANOPY' � .� 38 O 3D 38EM i ENTRY A C-38 (SEE WIRING DIAGRAM, SHEET E-004) OE 0 22 OE 22 OE • 22 OE•22 LINETYPE LEGEND APPLIES TO THIS SHEET ONLY. NORMAL POWER. 3/4"C. 2#12 & 1#12 GND. PANELBOARD "C" REFER TO SHEET E-501. C-22 3#1 0-1 /2"C. OE Q 22 DRIVE TWRU C-1 A is pimism mem trim C-1 PYAVA FJP711 PM PAM EMU ME MS I PS (SERV CE AFEA UNISEX "A" 5A,5EM UNISEX "B" w OE S 20 13EM,NL D3 13 CT -2 DIN NG D3E 11 EM (TYPICAL) SE"VING 13E 13E 13E CT -1 ORDERING 11 D3E 11 EM OO_ C-11 CT -1 _ 11 EM, 11NL TO CANOPY AT DRIVE THRU ENTRY OE •20 DRIVE THRU ENTRY KEYNOTES (APPLY TO THIS SHEET ONLY) OE• 20 ROUTE CIRCUIT THROUGH "T-500" LIGHTING CONTROL PANEL. REFER TO RELAY CONTROL PANEL CONNECTION DIAGRAM ON SHEET E-002. ® LOCATE RECEPTACLE FLUSH IN CEILING FOR CONNECTION TO OWNER FURNISHED INTERIOR NEON SIGN. ® FOR SIGNAGE; CONNECT AS REQUIRED. GROUND ALL LOCATIONS IN ACCORDANCE WITH N.E.C. AND MANUFACTURER'S REQUIREMENTS. SIGN IS FURNISHED WITH INTEGRAL DISCONNECTING MEANS. ® UP TO RESTROOM EXHAUST FAN ON ROOF. SEE ROOF ELECTRICAL PLAN, SHEET E-250. ® PROVIDE BATTERY PACK IN CEILING SPACE FOR AWNING LIGHT. COORDINATE WITH SIGN CONTRACTOR AND PROVIDE BATTERY PACK COMPATIBLE WITH FIXTURE PROVIDED WITH SIGN PACKAGE. CONNECT FIXTURE SO THAT BATTERY PACK IS NOT SWITCHED WITH LIGHTS, BUT ALL LAMPS ARE SWITCHED. © FOR CONNECTION TO LIGHTING FIXTURES IN THE WALK-IN COOLER AND WALK-IN FREEZER WHICH ARE FURNISHED WITH EQUIPMENT. CONTRACTOR SHALL ROUGH -IN AND CONNECT ALL FIXTURES AS REQUIRED BY THE EQUIPMENT MANUFACTURER. PROVIDE FLUORESCENT LAMPS TYPE AS REQUIRED BY EQUIPMENT MANUFACTURER. ® CONNECT FIXTURE SO THAT BATTERY PACK IS NOT SWITCHED WITH LIGHTS, BUT ALL LAMPS ARE SWITCHED. ® REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATIONS OF PENDANTS (TYPES 'P1', 'Q', 'U' AND 'F'), DOWNLIGHTS (TYPE 'D3') AND WALL SCONCES (TYPE 'V') LIGHT FIXTURES. OE.� 20 VESTIBULE NON-ILLUM NATED PENDANT FIXTURE TYPE 'O' (SEE FIXTURE SCHEDULE ON E-002) (TYPICAL) D3E 11EM D3 11C O NL 0 0 atemummilillmmulum11111110= vir D3 11C O D3 11C O_ I D3 11C D3 11C 0 0 NL 11.11 11 EM 1111111 11111.111 'EINE OE • 20 OE 20 OE TYPICAL) 12 00 38,38EM p MAIN ENTRY CONNECT FIXTURE TO CIRCUIT AHEAD OF ALL SWITCHING OE 20 AND CONTROLS. THIS FIXTURE SHALL NOT BE SWITCHED. 10 INSTALL ALL JUNCTION BOXES IN THE PLAY AREA SO THEY WILL BE READILY ACCESSIBLE AFTER THE PLAYGROUND EQUIPMENT IS INSTALLED. O. TO WALK-IN DOOR FRAME HEATER. J -BOX TO BE ABOVE THE UNITS AND EXTEND DOWN ALONG THE FRONT AT 9'-6" AFF TO HEATERS. O. CANOPY LIGHTS PROVIDED BY THE CANOPY MANUFACTURER. ELECTRICAL CONTRACTOR SHALL CONNECT BRANCH CIRCUIT AND PROVIDE ROUGH -IN FOR LIGHTING. COORDINATE LOCATIONS WITH SIGN CONTRACTOR PRIOR TO ROUGH -IN. PROVIDE BATTERY PACK IN CEILING SPACE OF VESTIBULE FOR AWNING LIGHT (AT ENTRY VESTIBULES ONLY). COORDINATE WITH SIGN CONTRACTOR AND PROVIDE BATTERY PACK COMPATIBLE WITH FIXTURE PROVIDED WITH SIGN PACKAGE. 13 CONNECT FIXTURE SO THAT LAMP BALLAST AND EMERGENCY BALLAST ARE NOT SWITCHED. 'NL' ADJACENT TO FIXTURE INDICATES THAT FIXTURE SHALL BE ON 24 HOURS. 14 COORDINATE SWITCH INSTALLATION WITH MANUFACTURER. O LOCATION OF STORE OPEN/CLOSE LIGHT SWITCHES. REFER TO DETAIL #3, THIS SHEET. 16 PROVIDE #10 CONDUCTORS ENTIRE CIRCUIT LENGTH, TO EACH LUMINAIRE. ELECTRICAL LIGHTING PLAN 1/4" = 1'-0" PROVIDE BLANK FILLER (NO SWITCH) IN BUILDINGS WITHOUT A PLAY AREA 20 D3E 9,9EM SB -B EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. 0 1® PENDANTS PLAY AREA C-7 C-9 SB -A 0 0 DINING 100% C-11 SB -B SB -C 0 0 S.P.S.T. TOGGLE SWITCH (TYP. U.N.O.) INDICATES 2 POLE LIGHT SWITCH 0 KITCHEN C -1,C-3 2 SB -D 0 0 SERVING C-13 0 MENU BDS C-17 SB -E SB -F ® 0 NOTE: LOCATE JUNCTION BOXES IN CEILING SPACE ABOVE THE LOCATION OF THE SWITCHBANK FOR SPLICING OF LINE, LOAD, AND SWITCHED CONDUCTORS. PROVIDE GANGED BACKBOX FOR SWITCHES AS REQUIRED AND LABEL ALL CONDUCTORS SO AS TO INDICATE THEIR USE (LINE, LOAD, SWITCH), THE LOAD SERVED, AND THE CIRCUIT NUMBER. SWITCH BANK "SB" DETAIL NOT TO SCALE C-20 3#10-1 /2"C. TO CANOPY AT FRONT ENTRY Om RECEIVED CITY OF TUKWiLA NOV212017 PERMIT CENTER D C B A cr) v a) ■meg 0 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of .Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET LIGHTING PLAN SHEET NUMBER E-211 11/9/2017 5:07:43 PM E D A DT (MLOP) LANE \ 8 CONTROL STATION \ 00 MAIN TELEPHONE BACKBOARD "MTBB" PHONE/CABLE SERVICE ENTRANCE CONDUIT -VERIFY LOCATION SIZE AND QUANTITY WITH THE ELECTRICAL SITE PLAN TO RECEPTACLES AT SERVICE AREA ENTRY -- (GEN) B-38; 20/1 WP/F 38 , //i//...% //',, ./ I„T 1 1T' .1ITOl l 11i ./ • $2 1WPAINFAMW441,41 — — jhC B-38 38 fi P/GFI • G . c A.=:'m4.m I O"Abr, L5w' .. ... P,12/ +4': PROVIDE A 120 VOLT =-� - - CONNECTION TO THE 50 VA DRIVE THRU KITCHEN KITCHEN MAIN DITRIBUTION PANEL "MDP" REFER TO SINGLE LINE DIAGRAM, SHEET E-502. VERIFY LOCATION WITH SITE PLAN AND COORDINATE WITH THE ARCHITECTURAL ELEVATIONS. TO RECEPTACLES AT PLAYGROUND AREA B-38; 20/1 MOTORIZED DAMPER FOR THE-----) OFFICE FROM A GEN` PURPOSE RECEPTACLE CIRCUIT MULTI-PURPOSE PANELBOARD "POS” REFER TO SHEET E-501 _ FOUR (2") EMPTY CONDUIT FROM CEILING SPACE DOWN WALL AND TURN INTO COUNTER'S UTILITY CHASE FOR DATA AND POWER ALL CONDUITS STUB -UPS N THIS WALL TO BE INTO THE SERVING AREAS CEILING SPACE TWO (4") CONDUIT ABOVE CEILING FROM JUNCTION BOX ABOVE THE OFFICE CEILING TO A J -BOX ABOVE THE ASSEMBLY TABLE TO A J -BOX AT THE SERVING AREA WALL FREEZER COOLER PANELBOARD "A" REFER TO SHEET E-501 PANELBOARD "B" REFER TO SHEET E-501 EXTEND CONDUIT INTO ACESSIBLE 'CEILING SPACE PANELBOARD "D" REFER TO SHEET E-501 UNISEX "A" (GEN) B-29; 20/1 RR VEST. '— PANELBOARD "C" REFER TO SHEET E-501 UNISEX "B" rasa w;.57 -119:10 HEW; I SERVING AREA �. 6�:Pd$fiyFj i wu: \ BACK \ ENTRY TO RECEPTACLES AT SERVICE AREA ENTRY SECURITY KEYPAD, PROVIDE J -BOX AND 1/2" C STUB -UP TWO (2") EMPTY CONDUITCR3) FROM CEILING SPACE DOWN WALL TO COUNTER FOR DATA AND POWER B-38; 20/1 TR DINING AREA tl�sari lisps l:'..tigrl: PROVIDE A 120 VOLT CONNECTION TO THE 50 VA MOTORIZED DAMPER FOR THE PLAY AREA FROM A GEN PURPOSE RECEPTACLE CIRCUIT ORDERING AREA 6" BEVERAGE CHASES BY OTHERS (TYP), SEE PLUMBING DRAWINGS FOR EXACT LOCATION AND QUANTITY (211C) B-36. SIGNAGE20/1 ITEMS OF IMPORTANCE : CONTRACTOR SHALL COORDINATE WITH DINING;.AREA SEATING'PACKAGE FOR TH LOCATIONS OF RECEPTACLES IN THE DIS AREA AT TABLES SO THAT THE RECEPTACLE IS UNDER THE TABLETOP AND NOT BEHIND A BOOTH SEAT PLAY AREA N N VESTIBUL B-29; 20/1 WP/GFI N M TO RECEPTACLES AT MAIN ENTRY DRIVE THRU ENTRY 3 KEY NOTES SECURITY: S1 PROVIDE SINGLE GANG JUNCTION BOX AND STAINLESS STEEL COVER PLATE WITH 7/8" HOLE IN CENTER.EXTEND 1" E.C. UP IN WALL TO ABOVE ACCESSIBLE CEILING. S2 PROVIDE 4"W X 4"H H X 3"D FLUSH JUNCTION BOX WITHOUT COVERPLATE. EXTEND 2" RIGID CONDUIT UP TO ABOVE ACCESSIBLE OFFICE CEILING AREA AND PROVIDE BUSHING ON CONDUIT END. 0PROVIDE A 4"W X 4"H X 3" D JUNCTION BOX WITHOUT COVERPLATE AND EXTEND A 2" CONDUIT DOWN AND BELOW GRADE TO EACH OF THE SITE'S POLE MOUNTED CAMERA LOCATIONS (SEE ELECTRICAL SITE PLAN FOR CONTINUATION) AND A 2" CONDUIT UP INTO THE ACCESSIBLE CEILING SPACE WITH A BUSHING ON THE CONDUIT END. PROVIDE A SINGLE -GANG JUNCTION BOX ADJACENT TO THE DOUBLE -GANG BOX WITH A 1.5" CONDUIT DOWN TO A SECOND SINGLE -GANG JUNCTION BOX AT THE CCTV MONITOR LOCATION. 0 PROVIDE TWO GANG WEATHERPROOF JUNCTION BOX AND STAINLESS STEEL PLATE WITH 7/8" HOLE IN CENTER FOR PANIC BUTTON. MOUNT AT APPROXIMATELY 48" A.F.F., EXTEND 1/2" RIGID CONDUIT OVER TO THE WALL AND THEN UP TO ABOVE ACCESSIBLE CEILING. SEAL PENETRATION AT WIC/WIF CEILING. 75 PROVIDE SINGLE GANG BOX WITHOUT COVER PLATE. EXTEND 1/2" CONDUIT UP IN WALL TO ABOVE ACCESSIBLE CEILING AND TURN TOWARD SERVING AREA SIDE OF WALL. S6 PROVIDE SINGLE GANG JUNCTION BOX ON INSIDE FACE OF PARAPET WALL APPROX. 12" BELOW TOP OF PARAPET WALL. EXTEND 1/2" CONDUIT DOWN TO ABOVE ACCESSIBLE OFFICE CEILING. EXTEND 1/2" RIGID CONDUIT FROM TOP OF STRIKE -SIDE DOOR FRAME CHANNEL TO ABOVE ACCESSIBLE CEILING. S8 EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" WITHIN EITHER HINGE -SIDE DOOR VERTICAL FRAME MULLION TO ABOVE ACCESSIBLE CEILING. O. PROVIDE SINGLE GANG JUNCTION BOX WITHOUT COVERPLATE. EXTEND 1/2" CONDUIT UP IN WALL TO ABOVE ACCESSIBLE CEILING AND TURN TOWARD SERVING AREA SIDE OF WALL. 0 PROVIDE SINGLE GANG, WEATHER-PROOF JUNCTION BOX WITH STAINLESS STEEL COVER PLATE MOUNTED 18" FROM THE CORNER OF THE SERVICE AREA AND JUST BELOW ROOF DECK MOUNTING BRACKETS. ROUTE 1" EMT CONDUIT FROM THE BOX SURFACE MOUNTED JUST BELOW THE ROOF DECK MOUNTING BRACKETS AND TERMINATE THE CONDUIT AT 11 EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" WITHIN STRIKE -SIDE WINDOW FRAME MULLION TO ABOVE ACCESSIBLE CEILING. • PROVIDE SINGLE GANG, WEATHER-PROOF JUNCTION BOX WITH STAINLESS STEEL COVER PLATE MOUNTED JUST ABOVE THE STRIKE SIDE OF OUTSIDE DOOR ON INSIDE OF SERVICE AREA. ROUTE 1" EMT CONDUIT SURFACE MOUNTED FROM BOX JUST BELOW THE ROOF DECK MOUNTING BRACKETS. TERMINATE CONDUIT IN THE ACCESSIBLE CEILING SPACE INSIDE THE BUILDING. 13 EXTEND 1/2" RIGID CONDUIT FROM A POINT 3" INSIDE THE STRIKE -SIDE DOOR FRAME MULLION TO ABOVE ACCESSIBLE CEILING. .0 PROVIDE JUNCTION BOX ON THE LATCH SIDE OF THE ROOF ACCESS HATCH WITH 1/2" C ABOVE THE CEILING TO THE OFFICE CEILING SPACE FOR A DOOR CONTACT. 38 WP/GFI N C) N M WP/GFI i7.r....1 r FTTM ,-T, MAIN --ENTRY N m POWER AND SYSTEMS PLAN 1/4" = 1'-0" 5� KEY NOTES - COMMUNICATIONS: C1 PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC200RR), ONE WITH 3" CONDUIT STUBBED UP INTO THE CEILING SPACE FOR VIDEO AND ONE WITH A 2" CONDUIT STUBBED UP INTO THE CEILING SPACE. FOR AUDIO AND DETECTOR LOOP. C2 PROVIDE JUNCTION BOX, LESS COVER PLATE, AND EXTEND 1" E.C. UP IN WALL TO ABOVE CEILING FOR INSTALLATION OF WIRELESS COMMUNICATION CONTROL UNIT. C3 PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC200RR) WITH STAINLESS STEEL COVER PLATE AND HOLE IN PLATE FOR AUDIO WITH 2" CONDUIT TO THE DT DUAL -LANE ORDERING AREA AND A 2" CONDUIT STUBBED UP INTO THE CEILING SPACE. PROVIDE TWO DOUBLE -GANG RINGS (CARLON #SC200RR) WITH STAINLESS STEEL COVER PLATE AND HOLE IN PLATE FOR VIDEO WITH 3" CONDUIT TO THE DT DUAL -LANE ORDERING AREA AND A 3" CONDUIT STUBBED UP INTO THE CEILING SPACE. 0 PROVIDE SINGLE GANG BOX WITH 3/4" EMPTY CONDUIT STUB -UP INTO ACCESSIBLE CEILING SPACE FOR OWNER DRIVE-THRU HARD -WIRED BACKUP AUDIO SYSTEM. © PROVIDE SINGLE GANG JUNCTION BOX WITH 3/4" C. STUP-UP INTO ACCESSIBLE CEILING SPACE. KEY NOTES - POS SYSTEM: 0 PROVIDE A 'RETROFIT' DOUBLE -GANG RING (CARLON #SC200RR) FOR OWNER'S DEVICE PLATE WITH A 3" EMPTY CONDUIT AT THE OPENING IN THE WALL UP TO THE CEILING SPACE FOR OWNER'S DATA CABLES. 0 PROVIDE JUNCTION BOX FOR TERMINATION OF 1" CONDUIT. PROVIDE 1" CONDUIT EXTENDING FROM CEILING AND TERMINATED AT JUNCTION BOX ON THE SERVING AREA SIDE OF THE WALL. COVER PLATE PROVIDED BY OWNER'S POS SYSTEM VENDOR. R3 PROVIDE TWO 2" CONDUIT FROM THE JUNCTION BOX ABOVE THE CEILING, DOWN THE WALL, BELOW THE FLOOR, AND TURN UP INTO THE CABLE AREA OF THE CASEWORK FOR OWNERS DATA CABLES. C. PROVIDE A 'RETROFIT' SINGLE GANG RING (CARLON #SC100rr) FOR OWNER'S DEVICE PLATE WITH A 2" EMPTY CONDUIT AT THE OPENING IN THE WALL UP TO THE CEILING SPACE FOR OWNER'S DATA CABLES. • PROVIDE JUNCTION BOX FOR TERMINATION OF 1" CONDUIT. PROVIDE 1" CONDUIT EXTENDING FROM CEILING AND TERMINATED AT JUNCTION BOX ON THE SERVING AREA SIDE OF THE WALL. POS SYSTEM SUPPLIER WILL PROVIDE COVER PLATE ON BOX. © PROVIDE SINGLE GANG EXTRA DEEP JUNCTION BOX MOUNTED ON THE MOUNTING PLATE WITHIN THE FRONT SERVING COUNTER CASEWORK. MOUNT BOX ADJACENT TO THE RECEPTACLE FOR EQUIPMENT 201. DO NOT MOUNT BOX BETWEEN EQUIPMENT 201 AND EQUIPMENT 204 RECEPTACLES. C6) KEY NOTES - MUSIC • • J PROVIDE JUNCTION BOX WITH STAINLESS STEEL COVER PLATE AND 3/4" HOLE IN PLATE WITH GROMMET ON HOLE IN PLATE. EXTEND 3/4" E.C. UP IN WALL TO ABOVE CEILING FOR MUSIC SYSTEM. g NOT USED. g PROVIDE THREE SINGLE GANG EXTRA DEEP JUNCTION BOXES STACKED ABOVE EACH OTHER WITH 1/2" CONDUIT FROM EACH TO THE TOP BOX AND A 1" CONDUIT STUBBED INTO THE CEILING SPACE. FOR MUSIC SYSTEM VOLUME CONTROLS. ® PROVIDE A SINGLE GANG EXTRA DEEP JUNCTION BOX AT 74" AFF WITH 1/2" CONDUIT STUBBED INTO THE CEILING SPACE. FOR MUSIC SYSTEM VOLUME CONTROLS. GENERAL NOTES: ALL SECURITY, POS, MUSIC, COMMUNICATIONS, AND POWER ROUGH -IN SHALL BE INSTALLED DURING THE FRAMING/ROUGH-IN PHASE OF CONSTRUCTION. 2. REFER TO KITCHEN EQUIPMENT SHEETS FOR EQUIPMENT ELECTRICAL ROUGH -IN ELEVATIONS ABOVE FINISHED FLOOR. 3. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH PULL STRING. 4. PROVIDE INSULATED BUSHINGS AT TERMINATION POINTS OF ALL CONDUITS FOR LOW VOLTAGE WIRING. 5. THE ELECTRICAL INSTALLER SHALL COORDINATE THE ROUTING OF ALL CONDUIT IN THE BUILDING WITH OTHER TRADES (SPECIFICALLY THE DUCTWORK INSTALLATION) TO AVOID CONFLICTS OF SPACE REQUIREMENTS IN WALLS AND CEILING SPACES. 6. ALL. RECEPTACLES SHALL BE PIGTALED. FEED THROUGH OF BRANCH CIRCUIT WIRING, THROUGH RECEPTACLE DEVICE, SHALL NOT BE PERMITTED. EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. SIDE ENTRY FOR POWER PLAN KEY NOTES, REFER TO SHEET E-301. REFER TO THE ELECTRICAL SITE PLAN FOR ADDITIONAL REQUIREMENTS FOR THE DRIVE-THRU CASH STATION ("D" KEYNOTES) ELECTRICAL KEY PLAN 1/8" = 1'-0" • N RECEIVED CITY OF TUKWILA, NOV 21 2017 PERMIT CENTER D B A U) o 01111.10 C) Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from • authorized project representatives. Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer 0 SHEET L POWER AND SYSTEMS PLAN SHEET NUMBER E-221 11/9/2017 5:08:19 PM 100A/3P SUBFEED IN PANEL -A n E 60A NON-FUSED NEMA 3R DISCONNECT ON EACH UNIT 0 Cri B-25 SECURITY SYSTEM SIREN BOX, REFER TO POWER PLAN KEYNOTE 'S6' ON E2.21 25 WP WP (SEE SHEET E-502) / 1 WP WP K14) A-38 2#10,1# A-36 3P,WP VIA CT -10 EF -2) A-36; 25/1 VIA CT -10 EF -2 120V, 1PH 3/4 H.P. EF -1 120V, 1PH 3/4 H.P. A-55,57,59 WP AC -1 208V, 3PH 128.4 FLA 150A MOCP PROPOSED LOCATION OF FUTURE INVERTERS AND METERING EQUIPMENT ASSOCIATED WITH SOLAR POWER READINESS WP 1111 41111 10 200AS 41111 104% 4.11 IN el OS EF -3 120V, 1PH 1/8 H.P. DOWN TO LIGHT , FIXTURE. CIRCUIT IN I RESTROOM. SEE E2.11 0 / RECEPTACLE ON THE KNOCKOUT PANEL OF THE UNIT WITH A WP (WHILE -IN -USE COVERPLATE7 B -F25 2071 TEE CONDENSER PLATFORM (TYP) 25 WP co AC -3 208V, 3PH 104 FLA 125A MOCP 25 MDP -6 11 (SEE SHEET E -50g 1 1- o REFER TO THE ELECTRICAL SITE PLAN FOR THE REFUSE ENCLOSURE LOCATION OK 34b MOUNTED ON WALL ABOVE DOOR AC -2 208V, 3PH 58.2 FLA 80A MOCP 25 WP B-25; 20/1 (TIE) (GEN) 175A/3P 1_113FEED IN PANELC /NORTHWEST CORNER OF MOUNT PHOTO -CELL ON ROOF (FIELD VERIFY) NOTE: REFER TO MECHANICAL DRAWINGS FOR ROOFTOP PPyCKAGED AC UNIT SCHEDULE. ALL UNITS ARE FURNISHED VyITH FACTORY INSTALLED DISCONNECT SWITCH. REFER TO SAME SCHEDULE FOR INDICATION OF UNITS FURNISHED /WITH FACTORY RECEPTACLE FOR COMPLIANCE WITH NEC 210-63. IWl F • • PROVIDE A 1.5" EMPTY CAPPED CONDUIT STUB -UP ON THE OF THE REFUSE ENCLOSURE AND EXTENDING UNDERGROUND TO PANEL -MDP FOR A FUTURE TRASH COMPACTOR PROVIDE TORK PHOTELECTRIC CELL #2101. MOUNT ON BOX WITH 1/2" CONDUIT EXTENSION. ADJUST SLIDE POSITION AFTER DARK SO THAT THE PARKING LOT LIGHTING DOES NOT PREVENT FIXTURE FROM BEING ON WHILE PARKING LOT LIGHTING IS ON. 34 WP GFI +60" A.F.F. B-34 STUB OUT 3/4" CONDUIT TO OUTSIDE BUILDING FOR IRRIGATION CONTROL REFUSE ENCLOSURE ELECTRICAL PLAN 717 ROOF POWER PLAN EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. REFER TO GENERAL NOTES, DETAIL #8 SHEET E-221 FOR ADDITIONAL REQUIREMENTS. •N KEY NOTES - ROOF ELECTRICAL PLAN: ROUTE ELECTRICAL CONDUITS TO UNIT CONNECTIONS THROUGH WEATHERPROOF RACEWAY FURNISHED WITH UNIT. COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS. MOUNT DISCONNECT SWITCHES FOR WIC AND WIF CONDENSERS ON UNISTRUT WITH CONDUIT DOWN INTO CEILING SPACE BELOW THRU ROOF PENETRATION DEVICE (NOT THRU ROOF), SEE SHEET A-1.7. PROVIDE FUSE SIZE PER MANUFACTURER REQUIREMENTS. CONNECT PHOTOCELL TO "T-500" SYSTEM TERMINALS AS DIRECTED BY "T-500" WIRING DIAGRAMS. PHOTO -CELL FURNISHED WITH PANELBOARD ORDER AND INSTALLED BY CONTRACTOR. c4) COORDINATE EXACT LOCATION OF CONDUIT AND DISCONNECT AT EXHAUST FAN. CONDUIT SHALL BE INSTALLED THROUGH ROOF ON OUTSIDE OF FAN CURB. CONDUIT SHALL BE LOCATED AT FAN HINGE SUCH THAT THE FAN HOOD CAN BE FULLY HINGED OPEN AND NOT TOUCH THE CONDUIT. PROVIDE 14" DIAMETER LOOP IN THE FLEXIBLE CONDUIT BETWEEN THE ROOF AND THE FAN ELECTRICAL CONNECTION. ROUTE NUMBER OF CONDUCTORS PER MANUFACTURER'S REQ'MENTS IN A 3/4" CONDUIT TO ICE MAKER BELOW FOR POWER AND CONTROL OF ICE MAKER CONDENSING UNIT. PROVIDE 1-1/2" CONDUIT ONLY, FOR FUTURE SOLAR POWER INSTALLATION, UP THROUGH ROOF FROM LOCATION OF MAIN DISTRIBUTION PANEL "MDP", BELOW AT GRADE. STUB, CAP AND MARK CONDUIT ON ROOF, AS REQUIRED TO PROVIDE PATHWAY PER ENERGY CODE (CEC) SECTION 110.10(e). A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT INDICATING THE INFORMATION FROM ENERGY CODE SECTION 110.10(B) THROUGH 110.10(C) SHALL BE PROVIDED TO THE ICrt&IMNIT2" E.C. THROUGH PARAPET FOR SECURITY SYSTEM CABLING. TERMINATE OPEN ENDS APPROXIMATELY 18" BELOW TOP OF PARAPET WALL AND ABOVE OFFICE CEILING. SECURE CONDUIT TO STRUCTURE. ROOF DRAIN HEAT TRACE SYSTEM ELECTRICAL CONTRACTOR TO PROVIDE 5W/FT 120V/1PH HEAT TRACE FOR ALL ROOF DRAINS. VERIFY TOTAL PIPE LENGTH WITH PLUMBING DRAWINGS. ROOF DRAIN HEAT TRACE CABLING PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL PIPE SHALL BE INSULATED AND JACKETED BY PLUMBING CONTRACTOR. HEAT TRACE: RAYCHEM #5XL1-CR (i) COORDINATE EXACT LOCATION OF CONDUIT AND DISCONNECT AT EXHAUST FAN. CONDUIT SHALL BE ROUTED THROUGH DUCTWORK, WITHIN FAN ROOF CURB, AND TO THE FAN WIREWAY. PROVIDE SEALTIGHT FITTINGS AS THE CONDUIT ENTERS AND LEAVES THE DUCTWORK. INTERLOCK WITH LIGHTING CIRCUIT IN RESTROOM. REFER TO E-211 FOR CONTINUATION. (-9- PROVIDE CONNECTION TO IRRIGATION CONTROLLER PER MANUFACTURER'S REQUIREMENTS. REFER TO IRRIGATION PLANS FOR ADDITIONAL INFORMATION AND EXACT LOCATION. (10) CONNECT POWER FROM EACH CONDENSING UNIT'S COMPRESSOR CONTACTOR TO THE EVAPORATOR COIL UNIT'S JUNCTION BOX BELOW. REFER TO E2.4 FOR LOCATION. - CONVENIENCE RECEPTACLE PROVIDED PRE-INSTALLED IN HVAC UNIT. CONNECT TO 120 VOLT CIRCUIT AS REQUIRED AND/OR AS INDICATED. 0 CONTRACTOR SHALL PROVIDE WEATHERPROOF HEAVY-DUTY DISCONNECT SWITCH AND FUSES. FUSES SHALL MATCH HVAC UNIT "MOCP" NAMEPLATE AMPS. SWITCH SHALL BE AS REQUIRED BY FUSE SIZE. CONTRACTOR SHALL NOT PURCHASE DISCONNECT SWITCH OR FUSES UNTIL HVAC UNIT AND NAMEPLATE IS PRESENT ON SITE. .0 EXHAUST FAN IS FURNISHED WITH A PREWIRED DISCONNECT. cm') RECEPTACLE IS PRE -WIRED TO UNITS POWER. 0. WEATHERPROOF JUNCTION BOX FOR CONNECTION TO ROOF DRAIN HEAT TAPE. FIELD VERIFY EXACT POINT OF CONNECTION. RECEIVFO CITY OF TUKIN1LA NOV 21 2017 PERMIT CENTER Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 A 4 3 2 milso 0 mit 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR— COMPLIANCE WITH NFPA 70 - NEC DEC 3 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. 0 SHEET L. ROOF POWER PLAN SHEET NUMBER E-250 11/9/2017 5:08:46 PM 1 i PROVIDE JUNCTION BOX WITH 2" CONDUIT, -- DOWN WALL, FROM ACCESSIBLE CEILING SPACE TO ELECTRICAL CHASE IN MILLWORK. TRANSITION FROM CONDUIT AND CONDUCTORS TO MC CABLE AT - JUNCTION BOX, ABOVE CEILING, FOR CIRCUITS WITHIN THE MILLWORK Co® D-38,40,42; 80/3 (30)( 522) D-32,34,36 0/3 aft (28) (28) (28) w v O 0 7. N N M N Q m 0 N O � z CD 0 0 N N m m N LC) co 0 Ln 0) 2/7//_:% i 10' B-12" 20/1 m D-38,40,42 :=3#4-1"C D-32,34,36 3#4-1 "C. j A-17 ABOVE HOOD A-17.20/1/GF 9 )(563D) A-23; 2',b/1 /G UNDERSLAB CONDUIT STUB UPS INTO THE CABINET BASE FOR ITEMS UNDER PASS-THRU .-..::_ _ :.. WINDOW. SEE SHEET E-221. 563S 42 (1)4) 183 A-25; 20/1/GF ._ I 0/1/GF. A25;2 i i1 11 �' CGF POS-2!-4/1-5/1� I'°= 4 IG OUTLET I!i / @ GF J ,v IG. 1G' OIG G R2) • 5 0 B-14; 20/1 C® 1 j BELOW #560i' L_lj \I F(R2 IG OIG IG OIG MCS m • D-26,28,30; 80/3 10" P&S BOX 5050 20',22,24; 60/3 i 0.) co Q 10 rn ho 10 cc C%) 0 0_ I^ 0 CO POS -2. 1/15/IG 4 IG OUTLETS IG -8 0 ea 25 / B-49,51,53 4#6,1#10G.,1-1 /4"C. (184) (550 ) (184 CJ FAN & LIGHTS B-12,14. A-23,25 -- - --' ' 1.1.D-26,28,30 3#4-1"C. / - --PROVIDE JUNCTION BOX WITH 2" CONDUIT, DOWN WALL, FROM ACCESSIBLE CEILING SPACE TO ELECTRICAL CHASE IN MILLWORK. TRANSITION FROM CONDUIT AND CONDUCTORS TO MC CABLE AT JUNCTION BOX, ABOVE CEILING, FOR CIRCUITS WITHIN THE MILLWORK 0 0 10 D-20,22,24 3#6-1 "C. / 8 400 B-62; 20/1/GF �7TWISTLOCK 17 B-55,57,59; 60/3 POS -8; 15/1/G M CO DJ -4)(25) 11► GF IG -8. es e B-62 GF 11► III GF // 111 -4`8®-s.: IM B-10 A-34 _..... F B-2,4,6 NOTE: THE INTEGRAL 15A AND 20A RECEPTACLES IN THE CL TABLES ARE FED FROM GFCI BRANCH BREAKERS INTERGRAL WITHIN EACH TABLE B-55,57,59 4#6,1#10G.,1 -1/4"C. 564 (120D) B-61,63,65; 60/3 B-64 2#10-3/4"C. ;/ //, ' // i• / POS -8; 15/1/GF_ B-61,63,65 4#6,1#10G.,1 -1/4"C. r -I 1- (500A) IG -8 _.(500A) 0 0 47, (500B) 'POS -8(P3) D-2,4,6 D-8,10,12.. 3#10-1"C. 3#10-1"C. ra (500B) • /. 26 --_—' D-1,3,5 3#8-3/4"C 7 7.. - \) !�l ArAv. 26 d CO 0 L0 0) 0) m 2#10-3/4"C. — W 1- N co io N 0 CO 'D-31,33,35- ;I 3#8-3/4"C T!`j:: 16 )I D-25,27,29- D-19,21,23 3#8-3/4"C. D-7,9,11 D-13,15,17 3#8-3/4"C. 3#8-3/4"C. 3#8-3/4"C. KITCHEN C-31,33 C-43,45 GROUNDING NOTE: ALL BRANCH CIRCUITS SHALL INCLUDE A GROUNDING, CONDUCTOR, AS SPECIFIED, SIZED PER 'CONDUIT AND CONDUCTOR SCHEDULE' ON SHEET E1.20. B1 w u_w u_w 0 m . 5 N m z 0) 0 0 :CO 0 B-74,76,78 tolommommilmommommIll GF GF • /7/ / // r . // / : / 7 // 0 0 N 0 O U 0 El 0 0 A-41 r 0 +48" ..., C-37,39 39,41 Li -43,45,47 �._ 3/4'C. D-14,16 2#10-3/4'C. GF Q► i/ / /-N w U_ w 0 J co 1-- cC 0 ABOVE HOOD B1 foommoommommommoomm (Th C-57,59 d' o0 N w 100 0 N O Lr? m cc 0 B-50,52,54 REFER TO THE LIGHT FIXTURE SCHEDULE FOR THE TYPE AND SPEC OF THE LIGHTS TO BE MOUNTED TO THE UNDERSIDE OF THE WIRE SHELVING. PROVIDE A SINGLE POLE SWITCH IN AN FS BOX MOUNTED TO THE SHELF WITH AN SO CORD WITH PLUG OF LENGTH TO PLUG INTO THE GENERAL PURPOSE DROP CORD AT THE REAR OF THE SHELVING (TYP) B1 B1 C-45,47 1 e ' 7 // j.%./ / /// / / /i /i / /,. / //// /i /i SEAL -OFF FITTING (TYP)''' IN CEILING SPACE ON KITCHEN OF WALL lhilkiMINONWIRIMMIEhlIMOMMEkk A-32 ROUTE THE CONDUIT FOR THE EVAP COILS, HEAT TAPE, AND SECURITY SYSTEM PANIC STATIONS AT THE CEILING OF THE WIC/WIF FROM THE ABOVE CEILING J -BOXES LOCATED ABOVE THE WIC/WIF —1 B-35 C-51,55 GF W P/GFI.I 35 / 1/../ //, /// _ �! C22 O O 3 I. / I +48' r -i 8 B-28 MULTI -AREA PURPOSE CONNECT THE FREEZER'S DOOR FRAME HEATER TO THE UNITS LIGHTING CIRCUIT PROVIDE AN EMPTY FLUSH JUNCTION BOX WITH A 1" CONDUIT TO PANEL -D FOR FUTURE USE. SEAL -OFF FITTING (TYP) IN CEILING SPACE ON KITCHEN OF WALL M2,. 1------1-""r! FREEZER PROVIDE DISCONNECT SWITCH INA NEMA 3R ENCLOSURE AT THE UNIT'S EVAPORATORE COIL ROUTE THE CONDUIT FOR THE EVAP COILS, HEAT TAPE, AND SECURITY SYSTEM PANIC STATIONS AT THE CEILING OF THE WIC/WIF FROM THE ABOVE CEILING J -BOXES LOCATED ABOVE THE WIC/WIF REFRIGERATOR PROVIDE DISCONNECT SWITCH - INA NEMA 3R ENCLOSURE AT THE UNITS EVAPORATORE COIL DOM NOTE FOR GF TYPE RECEPTACLES: THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP RECEPTACLE OUTLET BRANCH CIRCUITS IN THE KITCHEN/FOOD PREPARATION AREAS. GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE RECEPTACLE VIA A GROUND FAULT TYPE RECEPTACLE UNLESS OTHERWISE NOTED ON THE PLANS. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. NOTE FOR POS GF IN KITCHEN: THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP ISOLATED GROUND RECEPTACLE OUTLET BRANCH CIRCUITS IN THE KITCHEN/FOOD PREPARATION AREAS. GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE BREAKER VIA A GROUND FAULT TYPE BRANCH BREAKER. (GFCI TYPE ISOLATED GRD RECEPTACLES ARE NOT AVAILABLE.) KEY NOTES -POWER: LL co 0 0 Ca cn co cn 0 Cal 0 0 cc (1) NOTE: RECEPTACLES FOR THE POS EQUIPMENT SHALL BE THE ONLY ITEMS THAT CONNECT TO PANEL -POS. THERE SHALL BE NO OTHER LOADS CONNECTED TO THIS ISOLATED GROUND PANEL AND, IF SO, SHALL BE REMOVED AND RECONNECTED TO ANOTHER PANELBOARD AT THE EXPENSE OF THE CONTRACTOR. EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. PROVIDE 2 GANG DEEP BOX (2" MIN.) FOR ANSUL PULL STATION. EXTEND 1/2" CONDUIT FROM BOX, STUBBED ABOVE CEILING. PROVIDE EDWARDS #340-4N5 VIBRATING 4" DIAMETER BELL. BELL SHALL BE RATED AT 120 VOLTS. PROVIDE 120 VOLT WEATHERPROOF DOORBELL PUSH-BUTTON AT DOOR. PUSHBUTTON SHALL BE FLUSH MOUNTED. PROVIDE DORTRONICS SYSTEMS #W5286 -P25 CLEAR ANODIZED ALUMINUM PUSHBUTTON WITH SINGLE GANG SWITCHPLATE. COMMUNICATION UTILITY SERVICE ENTRANCE CONDUIT(S). EXTEND WITH PULL STRING FROM TELEPHONE SERVICE JUNCTION BOX IN ELECTRICAL ROOM AS REQUIRED TO THE TELEPHONE/CATV/ISP UTILITY SOURCES. REFER TO SHEET ES -1 FOR ADDITIONAL INFORMATION. PROVIDE 41X8'X3/4" PLYWOOD BACKBOARD PER SERVING COMMUNICATIONS UTILITY COMPANY REQUIREMENTS. PROVIDE DUPLEX RECEPTACLE (ARLINGTON #DVFR2W) FOR CONNECTION TO FLY SYSTEM EQUIPMENT #211. SEE ELEVATIONS FOR MOUNTING HEIGHT. DO NOT CUT THE CORDSET FURNISHED WITH THE UNIT, BUT COIL THE CORD ON THE BACK OF THE UNIT PER MANUFACTURER'S DIRECTIONS. CORD SHALL NOT BE ABOVE CEILING PER ARTICLE 400.8 (5). TAMPER RESISTANT (TR) DUPLEX RECEPTACLE (IN THE DINING ROOM) WITH USB CHARGER SHALL BE COOPER/ARROW HART #TR7746-B (BROWN) WITH MATCHING COLOR 'DECOR' STYLE PLATE. JUNCTION BOX WITH 3/4" CONDUIT STUB -UP INTO THE CEILING SPACE FOR FUTURE AIPHONE INTERCOM FOR THE MLOP ORDERING CONTROL STATION. PROVIDE BLANK PLATE IF BUILDING IS SINGLE LANE DRIVE-THRU. OUTLETS IN THE CUT-OUT OF THE CASEWORK. PROVIDE 2 GANG DEEP BOX (2" MIN.) FOR EACH DUCT SMOKE DETECTOR INDICATED ON THE MECHANICAL DRAWINGS FOR INSTALLATION OF DUCT DETECTOR REMOTE ANNUNCIATORS BY MECHANICAL. THE DUCT SMOKE REMOTE ANNUNCIATORS ARE PROVIDED TO THE ELECTRICIAN WITH THE SUNCOAST ELECTRONICS PACKAGE OF GEAR AND CONTROLS. EXTEND 1/2" CONDUIT FROM EACH BOX AND STUB ABOVE CEILING. REFER TO GENERAL NOTES, DETAIL #4 SHEET E-221 FOR ADDITIONAL REQUIREMENTS. PROVIDE 6"H X 6"W X 4"D INCOMING COMMUNICATIONS SERVICE JUNCTION BOX AT 7 FT AFF. EXTEND TWO 2" CONDUIT WITH PULL STRING FROM THIS BOX UP INTO THE ACCESSIBLE CEILING SPACE OF THE KITCHEN OR OFFICE. PROVIDE #6 AWG INSULATED CU GROUND WIRE IN 3/4"C TO GROUND BUS IN PANEL -MDP. PROVIDE AS REQUIRED PER TELEPHONE, CATV AND/OR ISP UTILITY COMPANIES AS APPLICABLE. PROVIDE JUNCTION BOX AT +8'-0" A.F.F. WITH CONDUIT AND CONDUCTORS TO PANELBOARD FOR FUTURE CONNECTION TO BOOSTER PUMP. REFER TO THE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. PROVIDE TYPE B1 LIGHT FIXTURE. MOUNT TO THE UNDERSIDE OF THE WIRE SHELVING. CONNECT A SINGLE POLE SWITCH IN AN FS BOX MOUNTED TO THE SHELF. FROM FS BOX PROVIDE AN SO CORD WITH PLUG OF LENGTH TO PLUG INTO THE GENERAL PURPOSE DROP CORD/RECEPTACLE AT THE REAR OF THE SHELVING. CONTRACTOR SHALL COORDINATE EXACT LOCATION AND MOUNTING HEIGHT OF RECEPTACLES IN DINING AREA WITH ARCHITECTURAL PLANS AND FURNITURE INSTALLER PRIOR TO ROUGH IN TO INSURE THAT RECEPTACLES ARE ACCESSIBLE WHEN FURNITURE HAS BEEN INSTALLED. SEE SHEET E-004 AND THE ELECTRICAL SITE PLAN FOR THE DRIVE-THRU ORDER AREA REQUIREMENTS AND FOR THE LOCATION OF THE LIGHTING POLE(S) THAT WILL SERVE AS A LOCATION FOR CAMERAS. RECEPTACLE FOR WATER HEATER. PROVIDE PLUG AND CORDSETS. PROVIDE DIRECT CONNECTION TO CENTERLINE TABLE UNITS (ITEMS #120, #120 A & #120E3) PER MANUFACTURER'S REQUIREMENTS. ROUTE CONDUIT(S) DOWN FROM CEILING THROUGH ELECTRICAL CHASE TO POINT OF CONNECTION OF PREWIRED UNIT. RECEPTACLE FOR RECIRCULATIONG PUMP ROUTED VIA "T-500" CONTROL PANEL. PROVIDE PLUG AND CORDSETS. PROVIDE CONDUIT AND CONDUCTORS BETWEEN THE "T-500" LIGHTING CONTROL PANEL AND THE ANSUL SYSTEM PANEL (ITEMS #269 & #270). REFER TO WIRING DIAGRAM ON SHEET E-003 FOR ADDITIONAL INFORMATION. LL ENLARGED KITCHEN POWER PLAN .0 PROVIDE CONNECTION FOR WALL MOUNTED HEATER PER MANUFACTURER'S REQUIREMENTS. VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT PRIOR TO INSTALLATION. 0. PROVIDE SINGLE NEMA 5-15R CLOCK RECEPTACLE (SEE ELEVATIONS FOR MOUNTING HEIGHT) FOR CONNECTION TO DINING ROOM INTERIOR SIGNAGE PER MANUFACTURER'S g CONNECT EVAPORATOR UNIT IN FREEZER TO FREEZER CONDENSING UNIT CONTROLS LOCATED ON ROOF. SEE SHEET E-250. 0. CONNECT EVAPORATOR UNIT IN COOLER TO COOLER CONDENSING UNIT CONTROLS LOCATED ON ROOF. SEE SHEET E-250. 0. PROVIDE A NEMA -5-20R, 20A -230V RATED, SIMPLEX GFCI-TYPE RECEPTACLE FOR TRASH COMPACTOR/BALER SYSTEM AIR COMPRESSOR. VERIFY EXACT LOCATION AND MOUNTIUNG HEIGHT IN FIELD PRIOR TO INSTALLATION. 0. CONNECT AS REQUIRED TO CJ FAN VIA SPEED CONTROLLER. CONNECT HOMERUN VIA RELAY IN T-500 .0 PROVIDE JUNCTION BOX WITH STAINLESS STEEL COVER PLATE WITH 3/4" C.O. TO 6" ABOVE CEILING BEHIND EACH TRANSFER STATION. g SEE SHEET E-250, ROOF ELECTRICAL PLAN, FOR THE LOCATION OF THE ICE MACHINE'S CONDENSER AND ADDITIONAL REQUIREMENTS. 0. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) TYPE RECEPTACLE IN COMPLIANCE WITH THE NEC REQUIREMENT FOR KITCHENS. IF NOT NOTED AS GFCI, THEN THE BREAKER IS TO BE GFCI TYPE. O. VERIFY MOUNTING LOCATION FOR THE ICE MAKER (ITEM #380X) RECEPTACLES WITH THE INTERIOR ELEVATIONS. O. THE OUTLETS FOR THE THREE OPEN FRYERS (ITEM #522) ARE FURNISHED BY THE EXHAUST HOOD SUPPLIER AND INSTALLED BY THE CONTRACTOR. KITCHEN EQUIPMENT MARK NUMBER, SEE SCHEDULE FOR REQ'MENTS PANEL AND CIRCUIT NUMBER BRANCH BREAKER SIZE (AMP/POLES), REFER TO THE CONDUIT AND CONDUCTOR SCHEDULE FOR WIRE AND CONDUIT SIZE RELATED TO THE BREAKER (VERIFY) ( XX X -XX; AMP/POLE REFER TO THE KITCHEN ELEVATIONS FOR THE ROUGH -IN HEIGHT KITCHEN EQUIP NOMENCLATURE NO SCALE RECEIVFM CITY OF TUKWILA Nov 2 1 2011 PERMIT CENTER .0 OVERHEAD EQUIPMENT POWER (OEP) DROP CORD RECEPTACLES FROM A FLUSH MOUNTED CEILING OEP BOX. PROVIDE A -C -S OEP ASSEMBLY #12360-1000. ASSEMBLY WILL CONSIST OF A FLUSH CEILING OUTLET BOX, TWIST -LOCK PENDANT RECEPTACLES, STRAIGHT BLADE PENDANT RECEPTACLES, CORDS, STRAIN RELIEF, AND TWISTLOCK PLUGS. CONTACT MR. JIM JACOBSON AT A -C -S AT 800-639-7584 TO PURCHASE OEP BOX AND DROP CORD RECEPTACLES. PROVIDE LIQUID -TIGHT CONDUIT WITH CONDUCTORS FOR DIRECT CONNECTED EQUIPMENT. CONDUIT SHALL NOT TOUCH THE FLOOR WHEN EQUIPMENT IS IN PLACE. USE SUPPORT GRIPS W/ SUPPORT HOOK ATTACHED TO SHELVING ABOVE AS NEEDED. PASS & SEYMOUR MODEL #FS075-U-GH5 OR EQUIVALENT. LOCKABLE SINGLE POLE SWITCH SHALL SERVE AS THE LOCAL "IN -SIGHT" MEANS OF DISCONNECT FOR EQUIPMENT ITEM AS NOTED. THE SWITCH SHALL BE COOPER #S2983 AND INSTALLED PER THE DETAILS ON SHEET E-003. 3#10-3/4"C. TO DRIVE THRU MENU BOARD. SEE SHEET E-004 DETAIL #4 FOR MORE INFORMATION. PROVIDE 4/S BOX WITH SINGLE GANG PLATE WITH 1/2" GROMMETTED HOLE FOR VIDEO CABLE. PROVIDE 1" CONDUIT UP TO CEILING SPACE. BELOW FLOOR TO THE CENTAL CABINET STUB UP AREA. T1A/IST-LOCK 208V, 3PHASE, 30 AMP RECEPTACLE ABOVE HEATED AIR DOOR AT THE DRIVE-THRU WINDOW. PROVIDE AND INSTALLED A 30 AMP CORDSET WITH NEMA L14-30 PLUG INTO THE KNOCKOUT ON THE TOP OF HEATED AIR DOOR AND TERMINATE ON THE LUGS IN THE UNIT'S WIRING COMPARTMENT. FAN SHALL OPERATE AUTOMATICALLY, AS REQUIRED, WHEN DRIVE THRU WINDOW IS OPEN. ROUTE CONDUITS UNDER FLOOR UP WALL TO PANELBOARD AS SPECIFIED. PROVIDE TWO ADDITIONAL 1" UNDER FLOOR CONDUITS FOR FUTURE USE. ROUTE THROUGH LIGHTING SWITCHBACK "SB" FOR THE MENUBOARD POWER. CONTROLLED BY SWITCHED "F". SEE THE LIGHTING FLOOR PLAN. 4 3 2 1 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 Ur 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # PRINTED FOR Project Status DATE Cn DRAWN BY Issue Date Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representalives. 0 SHEET a. ENLARGED KITCHEN EL POWER PLAN SHEET NUMBER E-301 11/9/2017 5:09:19 PM E D C B A 7-7 ....� O i 9' 0 a M CO I- C i r-••• w CD N SINGLE GANG JUNCTION BOX WITH 3/4" STUB -UP INTO CEILING SPACE N M' V N n Cr) O N 0) ch 0 a_ rn ch 0 a POS -9 (P3) co" LABEL AS SWITCHED OUTLET N r- N I z 0 0 0 N U) 0 A-11 F- w 0 O 0 0 J a w 0 > 0 a - w F- N In F- w 0 CC 0 0 06 U(.9 w 0 > 0 9= a_ A-31,33 TWO 3" EMPTY CONDUIT FROM 6" ABOVE THE TOP OF THE NETWORK CABINET TO 6" ABOVE CEILING LOCATION OF THE INPUT & OUTPUT J - BOXES FOR THE PIB (POWER INTERFACE BOX) PROVIDED BY THE OWNER. POS -7 (P3) w 0 PANELBOARD "A" REFER TO SHEET E-501. w 0 SOUND SYSTEM VOLUME CONTROLS (M4 MULTI-PURPOSE AREA B PUMP A-35,37; 20/2 C-28,30 A-35,37 CONNECT THE FLEX WHIP FROM NETWORK CABINET IN WALL TO THE JUNCTION BOX ON CIRCUIT POS -4. POS -10(P3) PANELBOARD "POS" REFER TO SHEET E-501. PANELBOARD "B" REFER TO SHEET E-501. PANELBOARD "D" REFER TO SHEET E-501. PANELBOARD "C" REFER TO SHEET E-501. C-15 SERVICE AREA (AD 2) A-43; 20/1 A-43 - 2#10 & 1#10- 3/4"C. 20 A-3; 20/1 (TIE) TURN HORIZONTAL (FAN) 2" CONDUIT TO EACH POLE MTD CAMERA. SEE SHEET ES -1. 1 POS -4; 15/1/IG CABINET ', >>. HDVRA-1.6; 20/1 (TIE) Y\1B, A-16;:.20/1 (TIE VESTIBULE A- 3; 20/1 (TIE)SECURITY COMP POS -6; 15/1/IG SOUND SYSTEM VOLUME CONTROLS A-3,5 • N 0 N ENLARGED BACK OF THE HOUSE POWER PLAN 1 /2" = 1'-0" KEY NOTES - POS ELECTRICAL: 4P1) PROVIDE ONE ORANGE ISOLATED GROUND (IG) DUPLEX RECEPTACLE. PROVIDE GROUND FAULT PROTECTION FOR THESE DEVICES VIA A GROUND FAULT CIRCUIT BREAKER IF LOCAL CODE DEFINES THIS AS A FOOD PREPARATION AREA. E. USE TYPE MC CABLE FOR THE ISOLATED GROUND CIRCUIT: #12 HOT, NEUTRAL, GREEN GROUND, STRIPED ISO GRD. EACH 15A HOMERUN SHALL BE DEDICATED TO A CIRCUIT BREAKER VIA DEDICATED CONDUCTORS WITHIN A CABLE ASSEMBLY. ALL MC CABLES SHALL BE RUN OVERHEAD ABOVE THE CEILING AND RACKED TOGETHER ON J -HOOKS. NO SPLICES IN ANY HOMERUN CABLES FROM FIRST RECEPTACLE TO BREAKER. THE RECEPTACLE BACKBOX AND SYSTEM CABLE JUNCTION BOX FOR ITEMS 180 AND 182 SHALL BE TURNED HORIZONTAL. REFER TO THE KITCHEN EQUIPMENT ROUGH -IN ELEVATIONS FOR ADDITIONAL INFORMATION. 55 PROVIDE A 2" CONDUIT CHASE IN WALL FROM BELOW COUNTER, UP IN WALL, AND INTO CEILING SPACE FOR THE MC CABLE ROUTING FROM COUNTER AREA TO THE CEILING SPACE. PROVIDE TWO (2) 2" CONDUIT BELOW FLOOR FROM THE CEILING SPACE TO THE SERVICE COUNTER AREA CABLE CHASE FOR METAL -CLAD POWER CABLING. REFER TO SHEET E-221 FOR UNDER SLAB CONDUIT COORDINATION. �P4) IP6) KITCHEN EQUIPMENT MARK NUMBER, SEE SCHEDULE FOR REQ'MENTS PANEL AND CIRCUIT NUMBER BRANCH BREAKER SIZE (AMP/POLES), REFER TO THE CONDUIT AND CONDUCTOR SCHEDULE FOR WIRE AND CONDUIT SIZE RELATED TO THE BREAKER (VERIFY) ( XX ) X -XX; AMP/POLE REFER TO THE KITCHEN ELEVATIONS FOR THE ROUGH -IN HEIGHT KITCHEN EQUIP NOMENCLATURE NO SCALE NOTE FOR GF TYPE RECEPTACLES: THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP RECEPTACLE OUTLET BRANCH CIRCUITS IN THE KITCHEN/FOOD PREPARATION AREAS. GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE RECEPTACLE VIA A GROUND FAULT TYPE RECEPTACLE UNLESS OTHERWISE NOTED ON THE PLANS. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. NOTE FOR POS GF IN KITCHEN: THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP ISOLATED GROUND RECEPTACLE OUTLET BRANCH CIRCUITS IN THE KITCHEN/FOOD PREPARATION AREAS. GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE BREAKER VIA A GROUND FAULT TYPE BRANCH BREAKER. (GFCI TYPE ISOLATED GRD RECEPTACLES ARE NOT AVAILABLE.) NOTE: RECEPTACLES FOR THE POS EQUIPMENT SHALL BE THE ONLY ITEMS THAT CONNECT TO PANEL -POS. THERE SHALL BE NO OTHER LOADS CONNECTED TO THIS ISOLATED GROUND PANEL AND, IF SO, SHALL BE REMOVED AND RECONNECTED TO ANOTHER PANELBOARD AT THE EXPENSE OF THE CONTRACTOR. FOR POWER PLAN KEY NOTES, REFER TO SHEET E-301. EQUIPMENT GROUND : ALL BRANCH CIRCUITS AND FEEDERS SHALL BE PROVIDED WITH AN EQUIPMENT GROUND CONDUCTOR. REFER TO GENERAL NOTES, DETAIL #8 SHEET E-221 FOR ADDITIONAL REQUIREMENTS. CONCEAL CONNECTION FROM J -BOX TO WINDOW IN WALL, VERIFY ROUGH -IN LOCATION WITH DT WINDOW SUPPLIER B-16; 20/1 B-17; 20/1 A-1; 20/1 (TIE) A-7; 20/1 AIR CURTAIN WITH MICROSWITCH FURNISHED BY DIVISION 15, SEE SHEET M-2.1 FOR ADDITIONAL INFORMATION. A-44,46,48 3#10 & 1#10-3/4"C. IG H x. V � RI. B-44,46,48; 30/3 (AD -1) S-1.5144 /182 ' E %e Op • D POS -11; 15/1/IG (TIE POS -7; 15/1/IG TIE B-3; 20/1 (TIE) POS -7; 15/ JIG TIE DRIVE THRU lil B.POS-51 15/1/IG POS -11; 15/1/IG TIE 421 A-13; 20/1 POS -5; 15/1/IG TI POS -7 (P3) POS -11(P3) A-13 % it IA -39 20/1 TIE POS -2; 15/1/IG TI B-1; 20/1 TIE EF B-37; 20/3 B -15; 15/1/GF 30MA .E34',20/1 (300a ) B-19,2 1,23 - 3#10,1 #10G.,3/4"C. B-37,39,41 3#10,1 #10G.,3/4"C. • -r ............................ - F li ,�ixtt MEN - B-24; 15/1/GF 30MA co c) C") 0 M N SEE DETAIL ON SHEET E-004 FOR REQUIREMENTS A-2; 20/1 A-6; 20/1 A-4; 20/1 WP/GFI WP/GFI A-2,4,6 3 )POS -5 B-42,44 2#10 & • 1#10-3/4"C. ROUTE CONDUIT AS :' REQUIRED, WITHIN" MILLWORK TO RECEPTACLE(S) LOCATION. POS -5; 15/1/IG TIE POS -5; 15/1/IG (TIE) LO 0 U) M ch SCM (37) 0 O CO 0 0 0 e F- 0 LO ch CO CO N 0 0 0 e e 0 e a (37) ORDERING AREA 0 0 T ` LO L0 T I- 0 0 a O CO U) C 0 CO CO N 4- N (37) 2 0 Ch a a_ aCLCL a CO ENLARGED SERVING AREA POWER PLAN 1/2" = 1'-0" RECEIVE -7D CITY OF TUKWILA NOV 21 2011 PERMIT CENTER A mina C) Cv coch. 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 Lir co cos ac o 17333 Southcenter Parkwa FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR . COMPLIANCE WITH NFPA 70- NEC DEC 1 3 2017 City of Tukwila BUILDING DIVISION ARCHITECT'S PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. 0 SHEET ENLARGED BOH/SERVING POWER PLAN SHEET NUMBER E-302 11/9/2017 5:09:55 PM 4 3 2 1 • • • • • • • • • • • N • • N N N • N • N N • • • • • • • N • N • N • N N ! i l // / ////// / / ////// /1///// / / /1// / / //// / / ////// / / //// / // //// / / / //1/ / / ////// / ////// / / F4) 0O (F9 MAIN FIRE ALARM CONTROL PANEL KG4) //1/////✓/tel ///// //////���� P +12" (CO2) /Z F7 00 (G1) 04) (rs P (F4 BUILDING DEPARTMENT NOTE THIS SHEET IS FOR REFERENCE ONLY AND NOT PART OF ELECTRICAL PLAN CHECK SUBMITTAL. r • r (G3) i N FIRE ALARM & CO2 SYSTEMS PLAN 1/4" = 1'-0" • • • • • • • • • • • • • • • • • • • • • CO2 SYSTEM GENERAL NOTES: 0 CO2 DETECTION AND ALARMING SYSTEM SHALL BE ANALOX MODEL AX -60. PROVIDE AND INSTALLED BY STRONG SYSTEMS. • CENTRAL CONTROLLER STATUS TO BE MONITORED VIA BUILDING SECURITY SYSTEM IF ONE EXIST. 30 SYSTEM POWER TO BE PROVIDED VIA DEDICATED 24VAC SUPERVISED POWER SUPPLY WITH BATTERY BACKUP PROVIDED AND INSTALLED BY STRONG SYSTEMS. ® LOCATE SENSORS NO CLOSER THEN 5FT AND NO MORE THEN 15FT FROM THE BIB RACK. 05 ALL CABLING SHALL BE CONCEALED IN WALLS OR ABOVE THE CEILING. ® INSTALL "WARNING CO2 ALERT" SIGNAGE ON WALL AT EACH ANNUNCIATOR. 07 INSTALL "WARNING CARBON DIOXIDE GAS" SIGNAGE ON WALL AT EACH ANNUNCIATOR. ® INSTALL AX60 CO2 SAFETY SYSTEM SIGNAGE ON WALL AT THE CENTRAL CONTROLLER DEVICE. ® IN THE EVENT THAT THE BIB RACK AND CO2 BULK TANK ARE MORE THAN 30FT APART AN ANNUNICATOR WILL BE REQUIRED AT BOTH THE BIB RACK AND BULK TANK. DIRECTION FOR LOCATING DETECTION AND ALARM DEVICES A. BULk CO2TANK OR CYLINDERS i• DETECTOR MOUNTED AT 12" AFF AND WITHIN 15FT OF THE TANK. ii. IF TANK AND BIB RACK ARE IN SAME AREA AND WITHIN 30FT OF ONE ANOTHER, ONE DETECTOR MAY BE USED TO SERVE BOTH. iii. THE DETECTOR MUST NOT BE LOCATED ANY CLOSER THAN 5FT FROM THE BIB RACK. iv. ANNUNCIATOR AT TANK MOUNTED AT 60" AFF. v. ANNUNCIATOR AT EACH DOOR LEADING INTO AREA WHERE TANK IS STORED MOUNTED AT 60" AFF/ vi. IF TANK AND BIB RACK IN SAME AREA, ONE ANNUNCIATOR MAY BE USED IF VISIBLE TO BOTH TANK/BIB (THIS DOES NOT SUPERSEDE OR CHANGE ITEM IV). vii. SIGNAGE FOR ANNUNCIATOR MOUNTED AT 65" AFF TO CENTER. B. CARBONATORS AND SYRUP PUMPS AT BIB RACK. i. DETECTOR MOUNTED AT 12" AFF AND WITHIN 15FT OF CARBONATORS/PUMPS. ii. THE DETECTOR MUST NOT BE LOCATED ANY CLOSER THAN 5FT FROM THE BIB RACK. iii. IF TANK AND BIB RACK ARE IN SAME AREA AND WITHIN 30FT OF ONE ANOTHER, ONE DETECTOR MAY BE USED TO SERVE BOTH. iv. ANNUNCIATOR AT BIB RACK MOUNTED AT 60" AFF. v. IF TANK AND BIB RACK IN SAME AREA, ONE ANNUNCIATOR MAY BE USED IF VISIBLE TO BOTH TANK/BIB. vi. SIGNAGE FOR ANNUNCIATOR MOUNTED AT 65" AFF TO CENTER. C. IN PRE V7 EDITIONS OF THE SO8H, WHERE THE BULK TANK IS LOCATED IN THE SERVICE YARD, CO2 DETECTORS SHALL NOT BE PLACED WITHIN 15 FEET OF CO2REMOTE FILL BOXES TO PREVENT FALSE ALARMS DUE TO GAS PRESENT DURING THE FILLING OPERATION. KEY NOTES - FIRE ALARM: 0LOCATION OF THE FIRE PROTECTION SYSTEM (SPRINKLER) RISER WITH FLOW AND TAMPER SWITCHES. COORDINATE WITH THE VENDOR'S SHOP DRAWINGS FOR LOCATIONS AND QUANTITY OF DEVICES. CONTRACTOR TO PROVIDE A 4" SQUARE DEEP JUNCTION BOX IN AN ACCESSIBLE LOCATION BETWEEN THE WATERFLOW SWITCH AND THE TAMPER SWITCH WITH 3/4" FLEXIBLE METAL CONDUIT BETWEEN THE JUNCTION BOX AND EACH SWITCH. PROVIDE A 3/4" EMT CONDUIT FROM THE JUNCTION BOX TO THE KITCHEN'S CEILING SPACE. F2 LOCATION OF THE FIRE ALARM CONTROL PANEL (FACP) WITH DEDICATED 120V, 20A CIRCUIT (B-30) FROM THE FACP TO A LOCKED -ON BREAKER (circuit b-30) THAT IS PAINTED RED IN PANEL -B. (NOTE THAT A CEILING MOUNTED SMOKE DETECTOR ABOVE THE FACP IS REQUIRED.) CONTRACTOR TO PROVIDE A 6" X 6" X 3" JUNCTION BOX AT 52" AFF FLUSH IN THE WALL WITH A 2" EMT CONDUIT STUBBED 6" NTO THE CEILING SPACE ABOVE. 0 LOCATION OF THE EXHAUST HOODS' ANSUL SYSTEM CONTROL PANEL. F4 LOCATION OF A ROOFTOP AIR HANDLING UNIT WITH INTEGRAL DUCT SMOKE DETECTOR. FIELD VERIFY THE LOCATION OF THE DETECTOR IN THE UNIT WITH THE UNIT'S SUPPLIER AND INSTALLER. CONTRACTOR SHALL PROVIDE A 4" SQUARE JUNCTION BOX BELOW THE ROOFTOP AIR HANDLING UNIT IN THE CEILING, (SEE GENERAL NOTES FOR REQUIREMENTS OF BOXES INSTALLED IN THE CEILING.) 5 LOCATION OF A MANUAL FIRE ALARM PULL STATION. CONTRACTOR TO PROVIDE A SINGLE GANG BOX FLUSH IN THE WALL AT 48" AFF (CENTER OF BOX) WITH A 1/2" EMT CONDUIT STUBBED INTO THE CEILING SPACE OF THE KITCHEN. 0 A DEDICATED PHONE LINE FOR THE FIRE ALARM SYSTEM WILL BE PROVIDED IN AN ARRANGEMENT BY THE OWNER AT THE BUILDING'S TELEPHONE COMPANY DEMARCATION POINT AND WILL BE CONTINUED TO THE FIRE ALARM CONTROL PANEL BY THE OWNER'S VENDOR. Q LOCATION OF THE EXTERIOR ELECTRIC BELL DIRECTLY ABOVE THE FIRE DEPARTMENT CONNECTION (FDC) FOR ANNUNCIATION OF THE FLOW OF WATER IN THE FIRE PROTECTION (SPRINKLER) SYSTEM. CONTRACTOR SHALL PROVIDE A 4" SQUARE EXTERIOR JUNCTION BOX FLUSH IN THE WALL AT A HEIGHT ABOVE GRADE PER LOCAL REQUIREMENTS WITH A 3/4" EMT CONDUIT STUBBED INTO THE KITCHEN CEILING SPACE. F8 LOCATION OF THE REMOTE ANNUNCIATOR FOR THE FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE A 4" SQUARE DEEP FLUSH -MOUNTED JUNCTION BOX AT 48" AFF WITH A 3/4" EMT CONDUIT STUBBED 6" INTO THE CEILING F9 LOCATION OF THE INTERIOR AUDIBLENISUAL ALARM NOTIFICATION DEVICE. CONTRACTOR SHALL PROVIDE A 4" SQUARE DEEP FLUSH -MOUNTED JUNCTION BOX AT 96" ABOVE FINISH FLOOR WITH A 3/4" EMT CONDUIT STUBBED INTO THE CEILING SPACE. 10 LOCATION OF THE EXTERIOR BACKFLOW PREVENT (BFP) AND/OR POST INDICATOR VALVE (PIV) TO BE DETERMINED IN THE FIELD AND PER THE CIVIL SITE UTILITIES PLAN FOR THIS STORE LOCATION. CONTRACTOR SHALL PROVIDE A 2" RIGID NONMETALLIC CONDUIT (RNC) FROM THE BFP/PIV LOCATION UNDERGROUND AND TURN UP INTO THE MECHANICAL ROOM AT THE FIRE PROTECTION SYSTEM RISER. FIRE ALARM GENERAL NOTES: f':}1 OPTIONAL FIRE ALARM ITEMS: 1. THIS DRAWING IS TO PROVIDE BASIC INFORMATION FOR THE REQUIREMENTS OF A SPRINKLER MONITORING SYSTEM AND/OR A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE latest editions of the IBC, IFC, AND NFPA 72. 2. THE FIRE ALARM SYSTEM WIRING AND DEVICES WILL BE PROVIDED AND INSTALLED BY THE OWNER'S VENDOR, STRONG SYSTEMS. REFER TO STRONG SYSTEM'S SHOP DRAWINGS AND EQUIPMENT DATA BROCHURE FOR ADDITIONAL EQUIPMENT INFORMATION AND SYSTEM REQUIREMENTS. 3. CONTRACTOR TO PROVIDE SUITABLE BUSHINGS ON THE END OF ANY CONDUIT TO PREVENT DAMAGE TO FIRE ALARM SYSTEM CABLES. THE CABLES WILL BE INSTALLED BY THE SECURITY SYSTEM VENDOR. 4. PROVIDE A RIGIDLY MOUNTED JUNCTION BOX WITH T -BAR FASTNER FOR ANY DEVICES NOTED TO BE INSTALLED IN THE CEILING SUCH AS A CEILING MOUNTED SMOKE DETECTOR. 5. VERIFY LOCATION OF THE CEILING MOUNTED DEVICES WITH THE FIRE ALARM SYSTEM SHOP DRAWINGS AND WITH THE REFLECTED CEILING PLAN. TYPICALLY A CEILING MOUNTED SMOKE DETECTOR SHALL NOT BE WITHIN 36" OF A SUPPLY AIR OR RETURN AIR GRILLE AND NOT LESS THAN 4" TO ANY WALL. CO2 DETECTOR NOTES: G1 CO2 CENTRAL CONTROL UNIT - PROVIDE SINGLE -GANG BACKBOX AT 60" AFF WITH 3/4" CONDUIT STUBBED ABOVE ACCESSIBLE CEILING SPACE. g CO2 ANNUNCIATOR UNIT - PROVIDE SINGLE -GANG BACKBOX AT 60" AFF WITH 3/4" CONDUIT STUBBED ABOVE ACCESSIBLE CEILING SPACE. G3 CO2 SENSOR UNIT - PROVIDE SINGLE -GANG BACKBOX AT 12" AFF WITH 3/4" CONDUIT STUBBED ABOVE ACCESSIBLE CEILING SPACE. • CO2 POWER SUPPLY - PROVIDE SINGLE GANG BACKBOX AT 18" BELOW CEILING WITH 3/4" CONDUIT STUBBED ABOVE ACCESSIBLE CEILING SPACE PROVIDE A DUPLEX OUTLET, AND CONNECT TO A LOCAL GENERAL OUTLET CIRCUIT. FIELD VERIFY EXACT LOCATION WITH STRONG SYSTEMS 800-500-5566. RECEIVED CITY OF TUKWILA NOV 21 2017 PERMIT CENTER D C B • pocA Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 co co W ar.co 2 cal 0 .e 4 '... m g ›, ca .. m la LL m 0. 1 C a a) v OW = 0 45 m (2 i m M ce) 0 o co W T'll FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED. FOR COMPLIANCE WITH NFPA 70 o NEC DEC 13 2017 City of Tukwila BUILDING DIVISION (I) M ARCHITECT'S PROJECT # A CO PRINTED FOR Project Status 4011. DATE 011) DRAWN BY * 10 ▪ Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from •0y authorized project representatives. 0 SHEET h.FIRE ALARM & CO2 a. SYSTEMS PLAN Issue Date Designer SHEET NUMBER E-401 11/9/2017 5 :16:29 PM PANEL: A PANELVOLTAGE: 120/208 3P, 4W CIRCUIT CODE (CC): N : NON -CONTINUOUS LOCATION: KITCHEN BUS: 250A L : LONG -CONTINUOUS MOUNTING: FLUSH MAIN: L.O. R: DEMANDABLE REC EPTAC LES AIC RATING: 42K/10K SERIES RATED K: KITCHEN CKT NO. VA LOAD LOAD DESCRIPTION CCMR TYPE CNT. C. B. BUS C. B. TYPE CNT. CC LOAD DESCRIPTION VA LOAD CKT NO. A B C M R L TR P A B C X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TR P LRMCC R M A B I C 1 720 N B #190 TELEPHONE DT VIDEO N 15 4 15 20 1 20 1 N 1 1 K #305 TEA BREWER 1650 RESTAURANT) 3 2. 1 3 N 720 OFFICE GEN & MUSIC N N 4 2 20 1 20 1 1 1 1 K #305 TEA BREWER #5650 FOOD COOKER/WARMER 1650 4 . 5 K 1080 OFFICE GEN/PRINTER N GENERAL OUTLET 6 1 20 1 20 1 20 1 180 N GENERAL OUTLET K 180 6. 180 L 1200 6 #315 DRINK TOWER K 15 1 K 20 1 20 1 1 1 1 N DT CASH STATION RECEPTACLE 180 100 8 7 9 8 9 SPARE 2544 #380ZC ICE CONDENSER * N 1 20 1 20 1 20 1 10 L PANEL POS (THRU PIB) * K 1700 10 11 10 1260 OFFICE REC S. & #190 N 15 7 -- 20 1 20 1 20 1 12 K #315W DRINK TOWER K 1200 12 . 13 225 13 #421 U.C. REFRIG * K 1 1 -- 20 1 20 1 20 1 15 K #315W DRINK TOWER 1200 #560 FRY HOLDING STAT 14 . 1 14 15 15 480 #420 U.C. REFRIG * K N 1 WATER. RECIRC. PUMP * 20 1 20 1 1 1 1 N SECURITY SYSTEM * D.T. WINDOW 360 16 1 6 17 15 225 #420 U.C. REFRIG * K K 1 1 20 1 20 3 3 20 1 N #449 COOLER CONDENSER * #380ZC ICE CONDENSER * 817 18 18 17 225 `7280 #420 U.C. REFRIG * K K 1 1 20 1 -- -- -- SPARE -- N AND EVAP COIL 817 2544 20 19 21 19 2280 SPARE K SPARE -- L 20 1 -- -- SPARE 20 -- N 15 630 22 23 1090 #563D SANDWICH SLIDE K BAC KFED MAIN BKR 1 L 20 1 20 1 TOTAL 1 1 K #315W DRINK TOWER I 23 1200 24 . 25 25 548 ROOF REC EPTAC LES #563S SANDWICH SLIDE K 7 1 20 20 1 40 3 1 1 N #410 FREEZER CONDENSER * 1536 26 26 14.0 27 DINING AREA OUTLETS 864 #320 CARBONATOR K 50 1 1 20 1 -- -- K K -- N AND EVAP COIL 28 2451 28 . 29 DINING AREA OUTLETS 864 #320 CARB ONATOR K -- 1 1 20 1 -- -- -- - -- N - - - 30 2451 30 31 864 N #320 CARBONATOR K K 1 1 20 1 20 1 -- 1 IRRIGATION CONTROLLER N #410 FREEZER HEAT TAPE * 500 32 , . 31 943 #310 DOUBLE JUICE DISP. K 864 #320 GARBONATOR K 20 1 20 20 1 20 1 N 1 - - - N GENERAL OUTLET 35 180 34 33 35 K 1144 BOOSTER PUMP N 20 1 X X X X X X X X X X X > X 20 2 25 1 L N 1 N HOOD EXHAUST FAN 1 360 1656 36 37 37 1144 #300X DBL ICE C REAM MACHINE * K N 1 -- 20 20 1 25 1 4 1950 1 N HOOD EXHAUST FAN 2 1656 38 39 38 1800 1 720 GENERAL OUTLETS (#184) N 3 4 -- 20 1 20 1 SPARE 50 SPARE 40 SPARE 40 41 40 39 -- K 450 HOOD CJ FANS N ---- -- 30 20 1 20 1 K - #308 COFFEE MAKER 42 2000 SPARE 43 42 41 43 500 20 AIR DOOR AD -2 N 1 -- -- 20 1 30 3 2000 1 N HEATED AIR DOOR AD -1 2628 K 44 45 20 SPARE 20 1 7320 42 20 1 -- -- SPACE 46 -- N 47 GENERAL OUTLET 2628 46 47 20 SPARE 20 1 20 1 -- SPACE 48 49 N 49 1800 2628 48 49 1 20 SPACE 60 3 20 1 1 SPACE K (SPARE) THAWING CABINET * 1800 51 5640 SPACE #601 FOOD C UTTER 51 50 51 K SPACE -- -- 20 1 SPACE 1 K #444 THAWING CABINET * 49 SPACE GENERAL OUTLET 52 52 53 1800 20 SPACE - -- -- 20 1 1 54 K #444 THAWING CABINET * SPACE 1800 54 54 55 6984 #120a CENTERLINE COLD TABLE K ROOFTOP UNIT AC -2 (58.2 FLA) N 1 60 3 100 3 56 57 SPARE 180 SPACE 56 57 1 56 57 K 6984 N -- -- 20 -- -- 1 58 K DROP C ORD. OUTLET 180 180 SPACE 59 1 58 59 K 6984 PHASE TOTALS N -- -- 20 -- -- 1 60 K #441 REFRIG SALAD PREP * 7645 1080 SPACE CONNECTED VA (CODE N): 61 60 6635 124101 10632 13097 PHASE TOTALS * - PROVIDE PHASE TOTALS 101671 9599 10132 20 Total Phase A: Total Phase B: Total Phase C: * - PROVIDE C IRC UIT 22577 1 CONNECTED VA (CODE N): 49988 20231 CONNECTED VA (CODE L): 1700 23229 CONNECTED VA (CODE R): 0 WITH LOC K -ON DEVICE 11/9/17 11:30 AM CONNECTED VA (CODE K): 14349 TOTAL C ONNEC TED KVA: 66.1 DEMAND KVA: -5.0 -- -- TOTAL ADJUSTED KVA: 61.1 TOTAL CONNECTED AMPS: 179.6 AMPS W/LCL: 183.2 0 PANEL: B PANELVOLTAGE: 120/208 3P, 4W CIRCUIT CODE (CC): N : NON-CONTINIJOUS LOCATION: KITCHEN BUS: 250A L : LONG -CONTINUOUS MOUNTING: FLUSH MAIN: L.O. R: DEMANDABLE REC EPTAC LES AIC RATING: 42K/10K SERIES RATED K: KITCHEN CKT NO. VA LOAD LOAD DESCRIPTION CC TYPE CNT. C. B. BUS C. B. TYPE CNT. CC LOAD DESCRIPTION VA LOAD CKT NO. A B ( C M R L TR P A B C X X X X X X X X X X X X X X X X X TR P L R M A B I C 125 200 N B #308D DAIRY DISPENSER * N 15 1 15 20 1 20 1 N 1 1 K #431 REFRIG. WORK TABLE 756 RESTAURANT) 3 2 1 #180/182 CTR. POS STATIONS N 2880 540 COM OUTLETS N 1 2 1 20 1 20 1 NETWORK CABINET 1 200 K #5650 FOOD COOKER/WARMER -- 1500 4 3 K 4 4 . 180 GENERAL OUTLET N 1 1 1 20 1 20 1 180 1 7 K GENERAL RECEPTACLE #180/182 D/T POS STATIONS 180 L 5 6 7 120 15 #300 MILKSHAKE DISPENSER K 3 1 N 20 1 20 1 20 9 50 100 SPARE N WATER HTR./RECIRC. PUMP 8 9 15 2544 #380ZC ICE CONDENSER * N 1 1 DINING -PLAY AREA LTG * 35 3 20 1 10 1 20 K #400 SGL R-1 FRY FREEZER * N 1 128 10 11 _ 2544 15 N -- 1405 -- -- 20 1 12 1 - 1 K #560 FRY HOLDING STAT 2 1840 12 L 13 2544 15 1 N -- SERVING AREA LTG * -- -- 20 1 15 1 20 K #560 FRY HOLDING STAT 1840 1 14 15 15 15 720 #380Z INTERIOR ICE MAKER * N 1 WATER. RECIRC. PUMP * SPARE 15 1 20 1 1 1 SPARE N D.T. WINDOW 500 1 6 1 15 _ 943 #310 DOUBLE JUICE DISP. K #671 MENUBOARD 1 20 1 35 3 20 SPARE 1 K #380ZC ICE CONDENSER * K 2544 18 17 19 `7280 1080 #300X DBL ICE CREAM MACHINE * K SPARE 1 25 3 -- -- SPARE 14 -- K L 2544 1 20 21 19 2280 21 K SPARE -- L -- -- -- -- SPARE 20 -- K 15 2544 22 23 2280 23 K BAC KFED MAIN BKR -- L -- -- 15 1 TOTAL 20 1 K #3803 INTERIOR ICE MAKER * 23 720 24 25 1260 1680 ROOF REC EPTAC LES N 11/9/17 1 1 :1 6 AM 7 0 20 1 20 1 DEMAND KVA: 1 K #440 B READING TABLE * 1440 TOTAL PANEL AMPS: 26 27 14.0 1080 DINING AREA OUTLETS N SPARE 7 50 20 1 20 1 20 1 K K (SPARE) BREADING TABLE * N 1440 28 29 - 1080 DINING AREA OUTLETS N SPARE 7 -- 20 1 2U 1 -- -- -- - SHARE N - - - 30 31 245 31 #211B/C FLY LIGHT SYSTEM N TIMER N K 20 1 20 1 20 1 -- N IRRIGATION CONTROLLER 900 MECHANICAL ROOM HEATER 32 33 33 943 #310 DOUBLE JUICE DISP. K K 1 1 20 1 20 1 2 1 3 N REFUSE ENCLOSURE - - - 380 34 35 35 '180 #607 COUNTERTOP LEMON JUICER K 33 1 2 20 1 X X X X X X X X X X X > X 20 1 1 L N T-500/SHUNT TRIP 1200 36 360 36 37 1800 7320 #300X DBL ICE C REAM MACHINE * K 20 1 25 20 3 20 1 L 4 1950 N GEN.OUTLET/DOORB ELL 900 39 38 39 MONUMENT SIGN * 1800 1 K 1 -- 3 -- -- 20 1 -- SPARE 50 SPARE 40 41 40 41 1800 -- K -- -- -- ---- -- 30 2 1 SPARE K - #308 COFFEE MAKER 42 2000 42 43 L SPACE K -- 20 -- 20 1 -- -- 5640 -- SPARE K 2000 45 44 45 #441 SALAD PREP. K SPACE 1 20 1 20 1 7320 42 43 5208 SPARE #524 SPACE 46 47 46 47 GENERAL OUTLET K SPACE 1 20 1 20 1 44 SPARE SPACE 48 49 48 49 1800 K #120 CENTERLINE HOT TABLE K 1 20 1 60 3 20 1 1 SPACE K (SPARE) THAWING CABINET * 1800 51 5640 50 #601 FOOD C UTTER 51 1800 K - -- -- 20 1 SPACE 1 K #444 THAWING CABINET * 49 1800 GENERAL OUTLET 52 53 1 1800 20 K - -- -- 20 1 1 54 K #444 THAWING CABINET * 50 1800 54 55 1200 #120a CENTERLINE COLD TABLE K 1 60 3 20 1 56 57 SPARE 180 GENERAL OUTLET 56 57 1 1200 20 K - -- -- 20 1 1 58 K DROP C ORD. OUTLET 180 180 58, 59 1 1200 20 K - PHASE TOTALS -- -- 20 1 32160 1 60 K #441 REFRIG SALAD PREP * 7645 1080 60 CONNECTED VA (CODE N): 61 2000 6635 #120c CENTERLINE TOASTER TABLE K 1 * - PROVIDE Total Phase A: Total Phase B: Total Total Phase C: C IRC UIT 60 7 20 1 6336 .- 1 CONNECTED VA (CODE L): K #401 WORK TOP FREEZER * 876 0 62 CONNECTED VA (CODE K): 63 TOTAL C ONNEC TED KVA: 2000 DEMAND KVA: K - TOTAL ADJUSTED KVA: -- -- 30 1 129.0 1 K #580 BISCUIT HOLD. CAB. 2880 64 65 2000 K - -- -- 20 1 SPARE 0 66 67 SPARE 20 1 20 1 SPARE 0 68 69 SPARE 20 1 20 1 SPARE 70 71 SPARE 20 1 20 1 1 K DROP CORD. OUTLET 180 72 73 SPARE 20 1 20 1 1 K #432 REFRIG WORK TABLE * 480 74 75 SPARE 20 1 20 1 1 K DROP CORD. OUTLET 180 76 77 SPARE 20 1 20 1 1 K #600 FLOOR MIXER 1176 78 79 SPARE 20 1 SPACE 0 80 81 SPARE 20 1 SPACE 82 83 SPARE 20 1 SPACE 180 84 134491 14907 14007 PHASE TOTALS PHASE TOTALS 13536112532 12060 Total Phase A: Total Phase B: Total Phase C: * - PROVIDE CIRCUIT 26985 CONNECTED VA (CODE N): 15977 27439 CONNECTED VA (CODE L): 0 26067 CONNECTED VA (CODE R): 0 WITH LOC K -ON DEVICE 11/9/17 1 1 :30 AM CONNECTED VA (CODE K): 64334 TOTAL C ONNEC TED KVA: 80.5 DEMAND KVA: -22.5 TOTAL ADJUSTED KVA: 58.0 TOTAL CONNECTED AMPS: 161.2 AMPS W/LCL: 1 61 .2 PANEL: POS PANELVOLTAGE: 120V, 1P, 2W CIRCUIT CODE (CC): N : NON -CONTINUOUS Location: OFFICE BUS: 60A L : LONG -CONTINUOUS Mounting: FLUSH MAIN: L.O. R: DEMANDABLE REC EPTAC LES AIC RATING: 10,000 FULLY RATED K: KITCHEN CKT NO. VA LOAD LOAD DESCRIPTION CCMR TYPE CNT. C. B. BUS TYPE CNT. C. B. BUS LOAD DESCRIPTION VA LOAD CKT NO. CC LOAD DESCRIPTION VA LOAD CKT NO. L TR PA B X X ) X ) X ' X ) X TR PLRMCC TR P A B X X X X X X X X X X X X X X X X X X X X C X X X X X X X X X X TR P L 125 #180/182 CTR. POS STATIONS N B 5 1 15 1 15 1 L 8 TOTAL N #183 MONITORS - PASS-THRU 1 400 2 1 RESTAURANT) 3 L 125 #180/182 CTR. POS STATIONS N 2880 5 , 15 1 15 1 L 1 K N NETWORK CABINET 1 200 4 5 -- 100 #180/182 AUX POS STATIONS N K 4 4 . 15 1 15 1 614 1 L N COMPUTER RECEPTACLE 10 180 6 7 1 100 #180/182 D/T POS STATIONS N L 4 K 15 1 15 1 6 3 L N CENTERLINE TABLE POS 13 75 8 20 9 50 100 #180/182 TRAINING POS STATIONS N WATER HTR./RECIRC. PUMP 4 15 1 15 1 1 DINING -PLAY AREA LTG * N NETWORK CABINET 200 10 11 20 75 #183 DRIVE-THRU MONITORS N - 3 EXT. REC EPT. SECURITY CAM. 15 1 15 1 r 11 1405 DINING AREA LTG * SPARE 4560 12 13 1 20 SPARE 2 -- -- L 15 1 15 1 13 225 SERVING AREA LTG * SPARE 12 13 14 15 1 20 SPARE 1 1 N 15 1 15 1 15 500 WATER. RECIRC. PUMP * SPARE 1 16 17 1 20 SPARE K -- 15 1 15 1 17 1740 #671 MENUBOARD SPARE 18 19 1 20 SPARE 4560 K 15 1 15 1 -- 1080 DIRECTIONAL SIGNS * SPARE 20 21 1 20 SPARE 14 4560 L 15 1 15 1 19 50 21 60 SPARE PARKING LOT LIGHTING L 22 23 6 20 SPARE 20 1 21 15 1 20 1 22 23 -- BAC KFED MAIN BKR PARKING LOT LIGHTING L 24 0 625 TOTAL 20 TOTAL 0 1055 23 Overall Total: 0 CONNECTED VA (CODE N): 1680 1680 CONNECTED VA (CODE L): 0 11/9/17 1 1 :1 6 AM CONNECTED VA (CODE R): 0 CONNECTED VA (CODE K): 0 TOTAL CONNECTED KVA: 1.7 DEMAND KVA: 0.0 TOTAL ADJUSTED KVA: 1.7 TOTAL PANEL AMPS: 14.0 AMPS W/LCL: 14.0 P PANEL: LOCATION: MOUNTING: C PANELVOLTAGE: 120/208 3P, 4W KITCHEN BUS: 250A FLUSH MAIN: L.O. AIC RATING: 42K/10K SERIES RATED CIRCUIT CODE (CC): N : NON -CONTINUOUS L : LONG -CONTINUOUS R: DEMANDABLE RECEPTACLES K: KITCHEN CKT N0. VA LOAD VA LOAD LOAD DESCRIPTION CC TYPE CNT. C. B. BUS 183.6 C. B. TYPE CNT. CC LOAD DESCRIPTION VA LOAD CKT NO. A B C M R L TR P A B X X X X X X X X X X X X X X X X X X X X C X X X X X X X X X X TR P L R M A B ( C 1 1025 37.4 37.4 KITCHEN LTG * L K TOTAL 13 20 1 20 1 1 RESTAURANT) 1 L BUILDING EXTERIOR SIGNAGE 1620 2880 2 , 3920 3 + 262.5 KITC HEN LTG * L K 11 20 1 20 1 1 -- L BUILDING EXTERIOR SIGNAGE K 1620 4 . 1440 5 5 614 RESTROOM LTG & EF -3 * L 1 K 10 20 1 20 1 1 -- L BUILDING EXTERIOR SIGNAGE K 1 620 6 ' 7 350 6 DINING AREA LTG * L #523 13 20 1 20 1 50 2 30 N WATER HTR./RECIRC. PUMP 1440 8 #505D CONVECTION OVEN , 2880 347 DINING -PLAY AREA LTG * L 4560 17 20 1 20 1 -- 2 - N EXT. REC EPT. SECURITY CAM. -- 360 10 9 r 11 1405 DINING AREA LTG * L 4560 55 20 1 20 1 2 -- -- L FLAGPOLE LTG * 100 12 ' 13 225 SERVING AREA LTG * L 12 13 8 20 1 20 1 1 1 N ROOF DRAIN HEATING CABLE 500 2 14 15 500 WATER. RECIRC. PUMP * N 1 14 20 1 20 1 K -- SPARE 16 17 1740 #671 MENUBOARD L 2 20 1 20 1 4560 K SPARE -- 18 -- 1080 DIRECTIONAL SIGNS * L 3 20 1 20 1 14 4560 L EXTERIOR BLDG LTG FRONT * 375 20 19 50 21 60 828 PARKING LOT LIGHTING L K 6 20 1 20 1 21 4560 SPARE K 22 23 -- 690 PARKING LOT LIGHTING L 5 20 1 20 1 2 22 23 L EXTERIOR DT SCONCE LTG * 50 24 25 276 PARKING LOT LIGHTING L -- -- 2 20 1 20 1 6600 24 SPARE 4560 26 27 K SPARE 50 3 80 20 1 20 2 K 1 N COMPRESSOR - TRASH SYSTEM 26 928 28 29 SPARE -- -- 20 1 -- -- -- - K N - - - 928 30, 31 180 4560 TIMER N K 1 -- 20 1 20 1 -- 1 N MECHANICAL ROOM HEATER 750 32 33 30 250 #184 IPAD K 1 SPARE FOR FUTURE FRYER 20 1 20 1 50 3 - N - - - 1 750 34 35 1000 #410/449 FRZE/COOLER, LTG * L 33 2 20 1 20 1 -- 1 L DINING ROON INTERIOR SIGNAGE -- 1200 36 37 1440 #440 B READING TABLE K 7320 1 35 20 1 25 1 5 -- L DRIVE-THRU CANOPY 1950 -- 38 39 1620 MONUMENT SIGN * L 1 7320 1 20 3 20 1 CHARGRILL COOKER K 1 SPARE 50 3 40 41 1620 L -- -- 20 -- 20 1 5208 K SPARE -- 42 43 1620 -- L -- K -- 20 -- 20 1 41 5640 SPARE K 44 45 -- 1080 #441 SALAD PREP. K 1 20 1 20 1 7320 42 43 5208 SPARE #524 C HARGRILL COOKER 46 47 1 180 GENERAL OUTLET K 20 1 20 1 20 1 44 SPARE 5208 48 49 180 GENERAL OUTLET K -- 1 20 1 SPACE SPACE 46 47 50 51 5640 1920 #601 FOOD C UTTER K 1 20 1 SPACE 52 53 49 180 GENERAL OUTLET K 1 20 1 SPACE SPACE 54 55 684 50 #432 REFRIGERATED TABLE K 1 20 1 SPACE 56 57 180 GENERAL OUTLET K 53 1 20 1 SPACE 58 59 180 GENERAL OUTLET K 1 20 1 PHASE TOTALS PHASE TOTALS SPACE 32160 60 70601 7645 7609 PHASE TOTALS CONNECTED VA (CODE N): 0 PHASE TOTALS 6635 1 3658 3898 0 * - PROVIDE Total Phase A: Total Phase B: Total Total Phase C: C IRC UIT 13695 CONNECTED VA (CODE R): 0 CONNECTED VA (CODE N): 6336 .- 11303 CONNECTED VA (CODE L): 23895 11507 CONNECTED VA (CODE R): 0 WITH LOC K -ON DEVICE 11/9/17 1 2:02 PM CONNECTED VA (CODE K): 6274 TOTAL C ONNEC TED KVA: 36.6 DEMAND KVA: -2.2 140.5 TOTAL ADJUSTED KVA: 34.4 TOTAL CONNECTED AMPS: 108.0 AMPS W/LCL: 129.0 PANEL: D LOCATION: KITCHEN MOUNTING: FLUSH PANELVOLTAGE: 120/208 3P, 4W BUS: 600A MAIN: L.O. AIC RATING: 42K/22K SERIES RATED CIRCUIT CODE (CC): N : NON -CONTINUOUS L : LONG -CONTINUOUS R: DEMANDABLE RECEPTACLES K: KITCHEN CKT NO. VA LOAD CONNECTED AMPS, LOAD DESCRIPTION CC TYPE CNT. C. B. BUS 183.6 C. B. TYPE CNT. CC LOAD DESCRIPTION VA LOAD CKT NO. A B C M R L TR P AB X X X X X X X X X X X X X X C X X X X X X X TR P L R M A B I C 1 4560 37.4 37.4 #523 PRESSURE FRYER K TOTAL 1 383.0 50 3 30 3 RESTAURANT) 1 K #505D CONVECTION OVEN 2880 IF TOTAL IS 201-325 KVA, THEN LOAD OVER 200 AT 50% + 200 2 3 + 262.5 4560 IF TOTAL IS OVER 800 KVA, THEN LOAD OVER 800 AT 20% + 476.3 K -- -- -- -- -- -- K 1440 4 5 4560 K -- -- -- -- K 1800 6 7 4560 #523 PRESSURE FRYER K 1 50 3 30 3 1 K #505D CONVECTION OVEN 2880 8 9 4560 K -- -- -- - -- K 1440 10 11 4560 K -- -- -- - -- K 1800 12 13 4560 #523 PRESSURE FRYER K 1 50 3 30 2 2 K #521 WARMING EYES 1950 14 15 4560 K -- -- -- -- K 1950 16 17 4560 K -- -- -- SPACE 18, 19 4560 #523 PRESSURE FRYER K 1 50 3 60 3 1 K #505G GRIDDLE/OVEN 6600 20 21 4560 K -- -- -- K 6600 22 23 4560 K -- -- -- -- -- -- K 6600 24 25 4560 #523 SPARE FOR FUTURE FRYER K 1 50 3 80 3 1 K #522 OPEN FRYER 7320 26 27 4560 K -- -- -- -- -- -- K 7320 28 29 4560 K -- -- -- -- -- -- K 7320 30 31 4560 #523 SPARE FOR FUTURE FRYER K 1 50 3 80 3 1 K #522 OPEN FRYER 7320 32 33 4560 K. -- -- -- -- -- -- K 7320 34 35 4560 K -- -- -- -- -- -- K 7320 36 37 5208 #524 CHARGRILL COOKER K 1 50 3 80 3 1 K #522 OPEN FRYER 7320 38 39 5208 K -- -- -- -- -- -- K 7320 40 41 5640 K -- -- -- -- -- K 7320 42 43 5208 #524 C HARGRILL COOKER K 1 50 3 20 1 SPARE 44 45 5208 K -- -- -- SPACE 46 47 5640 K -- -- -- SPACE 48 49 SPACE SPACE 50 51 SPACE SPACE 52 53 SPACE SPACE 54 377761 37776 38640 PHASE TOTALS PHASE TOTALS 36270133390 32160 Total Phase A: Total Phase B: Total Phase C: * - PROVIDE "LOCK 74046 CONNECTED VA (CODE N): 0 71166 CONNECTED VA (CODE L): 0 70800 CONNECTED VA (CODE R): 0 -ON" DEVICE 11/9/17 1 1 :31 AM CONNECTED VA (CODE K): 216012 TOTAL CONNECTED KVA: 216.1 DEMAND KVA: -75.6 TOTAL ADJUSTED KVA: 140.5 TOTAL CONNECTED AMPS: 390.3 AMPS W/LCL: 390.3 MAIN DISTRIBUTION PANEL "MDP' LOAD CALC NONE PANELBOARD NOTES • CONTROLLED BY RELAY IN T-500 CONTROL SYSTEM PANEL. PANELBOARD SUPPLIER TO PROVIDE NOTATION ON CIRCUIT THAT THE T-500 CONTROL SYSTEM ALSO HAS AN INTEGRAL BREAKER ON THE FAN CIRCUITS FOR DISCONNECTION OF POWER AT THE CONTROLLER PER THE NATIONAL ELECTRICAL CODE. OB CONTROLLED BY EXTERIOR SIGN RELAY IN T-500 CONTROL SYSTEM PANEL. © CONTROLLED BY EXTERIOR LIGHTING RELAY T-500 CONTROL SYSTEM PANEL. © CONTROLLED BY EXTERIOR LIGHTING RELAY - DUSK TO DAWN ZONE. pE CONTROLLED BY PARKING LOT LIGHTING CONTROL SWITCH. pF GFCI TYPE TO BE 30MA TYPE BREAKER.. OG CONTROLLED BY INTERIOR LIGHTING RELAYS IN T-500 CONTROL SYSTEM PANEL. LIGHTS SHALL TURN ON WHEN STORE IS OCCUPIED. SEE LIGHTING CONTROL SYSTEM DIAGRAM ON SHEET E-002 FOR ADDITIONAL INFORMATION. OH THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP RECEPTACLES IN THE KITCHEN/FOOD PREPARATION AREA. THE GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE RECEPTACLE AS A GROUND FAULT TYPE RECEPTACLE UNLESS NOTED OTHERWISE. (NOTE THAT THE RECEPTACLES LOCATED IN THE OEP BOX, THE KITCHEN/SERVING AREA RECEPTACLES SERVING POS EQUIPMENT, AND THE CIRCUIT FOR THE FLY SYSTEM SHALL BE PROTECTED BY GROUND FAULT TYPE CIRCUIT BREAKERS RATHER THAN GROUND FAULT TYPE receptacles SINCE ISOLATED GROUNDING TYPE RECEPTACLES, DROP -CORD RECEPTACLES, AND CLOCK TYPE RECEPTACLES ARE NOT AVAILABLE AS GROUND -FAULT TYPE RECEPTACLES.) GFCI BREAKERS REQUIRE A DEDICATED NEUTRAL (NOT SHARED) TO OPERATE PROPERLY. • PROVIDE EQUIPMENT GROUND FAULT PROTECTOR TYPE CIRCUIT BREAKER. RECEIVED CITY OF T ii W€LA NOV 21 2017 PERMIT CENTER D C B wvigA Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED .EON COMPLIANCE WITH NFPA 70 m NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECTS PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET PANEL SCHEDULES SHEET NUMBER E-501 ITEM SERVED CONNECTED KVA CALCULATED KVA CONNECTED AMPS, ALC ULATED AMP -a NEL "A" (& "POS") 66.1 66.0 183.6 183.2 PANEL "B" 80.5 58.0 223.6 161.2 PANEL "C" 29.0 34.8 80.6 96.8 PANEL "D" 216.1 140.5 600.3 390.3 RTU AC -1 46.2 46.2 128.4 128.4 RTU AC -3 37.4 37.4 104.0 104.0 TOTAL 475.4 383.0 1320.5 1063.9 SERVICE SIZE BASED ON NEC 220.88 (NOT ALL ELECTRIC RESTAURANT) TOTAL CONNECTED KVA 475.4 IF TOTAL IS 0-200 KVA, THEN TOTAL LOAD AT 100% IF TOTAL IS 201-325 KVA, THEN LOAD OVER 200 AT 50% + 200 IF TOTAL IS 326-800 KVA, THEN LOAD OVER 325 AT 45% + 262.5 330.2 IF TOTAL IS OVER 800 KVA, THEN LOAD OVER 800 AT 20% + 476.3 TOTAL AMPS AT 120/208V, 3PH, 4W 917.1 MAIN DISTRIBUTION PANEL "MDP' LOAD CALC NONE PANELBOARD NOTES • CONTROLLED BY RELAY IN T-500 CONTROL SYSTEM PANEL. PANELBOARD SUPPLIER TO PROVIDE NOTATION ON CIRCUIT THAT THE T-500 CONTROL SYSTEM ALSO HAS AN INTEGRAL BREAKER ON THE FAN CIRCUITS FOR DISCONNECTION OF POWER AT THE CONTROLLER PER THE NATIONAL ELECTRICAL CODE. OB CONTROLLED BY EXTERIOR SIGN RELAY IN T-500 CONTROL SYSTEM PANEL. © CONTROLLED BY EXTERIOR LIGHTING RELAY T-500 CONTROL SYSTEM PANEL. © CONTROLLED BY EXTERIOR LIGHTING RELAY - DUSK TO DAWN ZONE. pE CONTROLLED BY PARKING LOT LIGHTING CONTROL SWITCH. pF GFCI TYPE TO BE 30MA TYPE BREAKER.. OG CONTROLLED BY INTERIOR LIGHTING RELAYS IN T-500 CONTROL SYSTEM PANEL. LIGHTS SHALL TURN ON WHEN STORE IS OCCUPIED. SEE LIGHTING CONTROL SYSTEM DIAGRAM ON SHEET E-002 FOR ADDITIONAL INFORMATION. OH THE CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL 120 VOLT, 15 AND 20 AMP RECEPTACLES IN THE KITCHEN/FOOD PREPARATION AREA. THE GROUND FAULT PROTECTION SHALL BE PROVIDED AT THE RECEPTACLE AS A GROUND FAULT TYPE RECEPTACLE UNLESS NOTED OTHERWISE. (NOTE THAT THE RECEPTACLES LOCATED IN THE OEP BOX, THE KITCHEN/SERVING AREA RECEPTACLES SERVING POS EQUIPMENT, AND THE CIRCUIT FOR THE FLY SYSTEM SHALL BE PROTECTED BY GROUND FAULT TYPE CIRCUIT BREAKERS RATHER THAN GROUND FAULT TYPE receptacles SINCE ISOLATED GROUNDING TYPE RECEPTACLES, DROP -CORD RECEPTACLES, AND CLOCK TYPE RECEPTACLES ARE NOT AVAILABLE AS GROUND -FAULT TYPE RECEPTACLES.) GFCI BREAKERS REQUIRE A DEDICATED NEUTRAL (NOT SHARED) TO OPERATE PROPERLY. • PROVIDE EQUIPMENT GROUND FAULT PROTECTOR TYPE CIRCUIT BREAKER. RECEIVED CITY OF T ii W€LA NOV 21 2017 PERMIT CENTER D C B wvigA Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED .EON COMPLIANCE WITH NFPA 70 m NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECTS PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET PANEL SCHEDULES SHEET NUMBER E-501 11/9/2017 5:11:16 PM E D C B A SINGLE LINE DIAGRAM NOTES 1. VERIFY SERVICE LOCATIONS AND CONFORM TO THE REQUIREMENTS OF THE POWER COMPANY AND/OR DEVELOPER. POWER COMPANY AND/OR DEVELOPER SHALL BE CONTACTED PRIOR TO BEGINNING CONSTRUCTION TO ARRANGE AND VERIFY FOR THE INSTALLATION OF THE POWER COMPANY SERVICE, METER AND OTHER ITEMS. 2. GROUND ALL EQUIPMENT AND SERVICES IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE, LOCAL APPLICABLE CODES, AND ALSO AS INDICATED ON DRAWINGS. 3. MAKE THE NECESSARY INSPECTIONS OF EXISTING SITE AND SERVICE LOCATIONS AS REQUIRED FOR THIS WORK AND MAKE ALLOWANCE FOR EXISTING CONDITIONS BEFORE SUBMITTING BID. VERIFY WORK REQUIRED WITH POWER COMPANY AND TELEPHONE COMPANY. 4. CUT AND PATCH THE CONSTRUCTION WORK AS REQUIRED FOR PROPER INSTALLATION OF THE ELECTRICAL WORK. ALL PATCHING SHALL MATCH THE SURROUNDING WORK TO THE SATISFACTION OF THE ARCHITECT. ALL CONDUIT SHALL BE INSTALLED CONCEALED UNLESS SPECIFICALLY APPROVED BY THE ARCHITECT. COORDINATE SAW CUTTING WITH LANDLORD'S OR OWNER'S REPRESENTATIVE. 5. WIRE AND CABLE: A. CONDUCTORS SHALL BE COPPER, #12 AWG, MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE. B. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID AND #8 AWG AND LARGER SHALL BE STRANDED. INSULATION SHALL BE 600 VOLT, THHN/THWN. 6. PROVIDE ENGRAVED LAMINATED PHENOLIC BLACK -ON -WHITE (UNLESS NOTED OTHERWISE) NAMEPLATES SECURED TO EQUIPMENT WITH ADHESIVE AND SCREWS FOR PANELBOARDS, RELAY CABINETS, TRANSFORMERS, DISTRIBUTION BOARDS, AND MAIN PANELBOARD - IDENTIFYING EQUIPMENT DESIGNATION (CORRESPONDING WITH DESIGNATION USED ON DRAWINGS) AND EQUIPMENT VOLTAGE. LETTERING SHALL BE 1/4" HIGH. PROVIDE LABELS FOR CIRCUIT BREAKERS, FUSIBLE SWITCHES AND STARTERS IN PANELBOARDS AND DISTRIBUTION BOARDS FOR EACH DEVICE IDENTIFYING EQUIPMENT CONTROLLED. LETTERING SHALL BE 1/8" HIGH. 7. ALL DEVICES SHALL HAVE AN INTERRUPTING CAPACITY NOT LESS THAN THE POWER COMPANY AVAILABLE FAULT CURRENT, OR AS INDICATED ON THE DRAWINGS. 8. 120/208 VOLT BRANCH CIRCUIT PANELBOARD BREAKERS SHALL HAVE A MINIMUM U.L. SERIES RATING OF 65 KAIC WITH UP -STREAM FEEDER BREAKERS 9 MIPTI SPACE FOR MAIN PANELBOARD IS LIMITED. PANELBOARD MUST FIT IN ALLOCATED SPACE. COORDINATE WITH CONSTRUCTION AS REQUIRED. 10. 11. ALL WIRING SHALL BE IN CONDUIT, E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USE FOR FINAL CONNECTIONS AND WITH GREEN EQUIPMENT GROUNDING CONDUCTOR. EACH DISCONNECTING MEANS SHALL BE LEGIBLY MARKED TO INDICATE ITS PURPOSE. CIRCUIT BREAKERS SHALL BE APPLIED IN COMPLIANCE WITH THE SERIES COMBINATION RATINGS MARKED ON THE EQUIPMENT BY THE MANUFACTURER. MARK THE EQUIPMENT ENCLOSURES IN THE FIELD TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A SERIES COMBINATION RATING. THE MARKING SHALL BE READILY VISIBLE AND STATE THE FOLLOWING: "CAUTION - SERIES COMBINATION SYSTEM RATED 65,000 AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED" MARKING SHALL BE IN COMPLIANCE WITH NEC ARTICLE 110.22. 12. SWITCHBOARD AND PANEL BOARDS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER SECTION 110.16 OF THE ELECTRICAL CODE. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT. .110101111 Remote Panel POS 12 Ckt 120V 1 -Phase 3 -Wire w/ I.G. v-� 0 • ©s©II© t I iEl; ol I©®' 2 M pp 0 UTILITY POWER COMPANY TRANSFORMER AND SLAB BOX PROVIDE PRECAST CONCRETE PAD OR SLAB BOX PER POWER CO. REQUIREMENTS FIELD CONNECT SURGE ARRESTOR TO MAIN LUGS — FEEDER "PF" i I I L J 5" CONDUIT PER SERVING UTILITY COMPANY REQUIREMENTS PROVIDE A JUMPER ON THE LUGS OF PANEL POS SO THAT BOTH PHASE BARS ARE TIED TO THE ONE 120V PHASE CONDUCTOR FROM THE PIB SA METER SECTION FEEDER "SF" UGPS (EUSERC ORAS REQ'D) SINGLE LINE DIAGRAM PANEL POS (4) 4"C. EACH WITH 4#350 KCMIL (CU.) AND REQUIRED GROUND CONDUCTORS PER SERVING UTILITY COMPANY REQUIREMENTS A-10 2#10,1 #1 OG,1 #1 OIG -3/4"C. 1#6-3/4"C. TO TEL. SYS. GND. BUS 1 #3/0-3/4"C. TO MAIN COLD WATER PIB 1,200 A 3P MAIN 65KAIC "NNX" 1,200 AMP BUS 1 2 /--- MAIN DISTRIBUTION PANEL "MDP" (NEMA -3R) 120/208V - 3PH, 4W. - 1,200 AMPS 65 KAIC/SERVICE ENTRANCE RATED 3 4 5 6 7 8 250 A 250 A • 250 A 3P 3P 3P 65KAIC 65KAIC • 65KAIC "FXD6-A" "FXD6-A" "FXD6-A" MAIN BONDING JUMPER #3/0 #3/0 BOND 1#3/0 TO MAIN UFER GROUNDING ELECTRODE A-10 2#10,1 #10G,1 #1 OIG -3/4"C. 4#250kCMIL & 1#4 GND. - 3"C 600 A 200 A 175 A 65KAIC 65KAIC 65KAIC "LMXD6" "FXD6-A" "FXD6-A" SHUNT TRIP m z0 �z z� 0S - O 2 -O2 00 c Oz z °C I— POWER INTERFACE BOX (PIB) LOCATED UNDER THE OFFICE COUNTER. PROVIDE INCOMING J -BOX AND OUTGOING J -BOX FLUSH IN THE WALL WITH FLEX CONDUIT CONNECTION TO THE PIB. THE CONDUCTORS ARE TO CONNECT TO THE TERMINAL BLOCKS OF THE PIB. PANEL A 4#250kCMIL & PANEL B 4#250kCMIL & 1#4 GND. - PANEL C TWO (2) 3 1/2"C. WITH #1 GND. IN EACH 4#350MCM & PANEL D 3#3/0+1 #6GND-2"C 3#2/0+1 #6GND-1-1 /2"C ROOFTOP ROOFTOP UNIT AC -1 UNIT AC -3 (128.4 FLA) (104 FLA) 1 3 -POLE SPACE 3#8 50 A "FH" 0 CV MI MI 0 wU cn 00 zW cc� wQ cm ww Lu I-- 0'1 TVSS EQUIPMENT GROUND BUS NOT TO SCALE Note: This Cable is Factory Wired to the Power Interface Box Typical Isolated Ground Receptacle Isolated Ground Bar 0 0 IL �1t Contractor to Install #10 AWG Jumper Between Feeder Lugs ��Standard Ground Bar POWERVAR UPM Battery Backup ABCE1440-11 G UPM Output------)1— Receptacle PIB Output Power Interface Box (PIB) Terminals Normal Input Power Bypass Output Power PIB Outlet TB2 Input Power Terminals 11111 NOTES: 1. DASHED LINES INDICATE FIELD WIRING. SOLID BOLD LINES INDICATE CABLE & PLUGS THAT CONNECT TO THE UPM & PIB OUTLETS. 2. WIRING FROM INPUT BREAKER A-10 TO RIB MUST BE RUN IN SEPARATE CONDUIT OR MC CABLE FROM OUTPUT WIRING. 3. BRANCH CIRCUIT WIRING MUST BE RUN IN DEDICATED CONDUITS OR MC CABLE NOT SHARED WITH OTHER EQUIPMENT. MAIN DISTRIBUTION PANEL "MDP" (NEMA -3R) Note: Cable Provided with UPM GROUNDING FOR UPS SEPARATELY DERIVED SYSTEM To MDP Equipment Ground Bus. Install Unbroken with no Splices from "PIB" to "MDP" Ground Bus. To Panel A Neutral Bar 4. ALL BRANCH CIRCUIT RECEPTACLES MUST BE ISOLATED GROUND (IG) TYPE AND ORANGE COLORED TO IDENTIFY CRITICAL CIRCUIT. 5. POWERVAR UPM BATTERY BACKUP IS MOUNTED ON TOP OF THE PIB AND CONNECTS WITH CABLE PLUGS AND OUTLETS. 6. POWERVAR UPM BATTERY BACKUP IS A SEPARATELY DERIVED SYSTEM. NEUTRAL TO GROUND BOND IS MADE WITHIN THE POWERVAR UPM BATTERY BACKUP. POWERVAR LAPC / PANEL POS WIRING DIAGRAM NOT TO SCALE 1:11111og.a Breaker A-10 20 Amp Rated /\% 32" 38" ELECTRICAL ROOM PLAN VIEW 2 /1/2" _ 1'-0" FLOOR 38" 28" 32" SWITCHBOARD IS 28" DEEP 0 ® METER t - UGPS (PER POWER COMPANY) MAIN "MDP" ELEVATION 90" 2" RAISED r CONCRETE PAD CONDUIT ROUTING NOTE: ALL FEEDER CONDUITS TO AND FROM MAIN DISTRIBUTION PANEL SHALL BE RUN UNDERGROUND, BELOW GRADE, OR OTHERWISE CONCEALED. NO EXPOSED CONDUITS SHALL BE VISIBLE ON THE EXTERIOR OF THE BUILDING. INTEGRATED SWITCHBOARD "MDP" NOTES: 1. PURCHASE PANELBOARDS, WIREWAYS, SURGE ARRESTOR, AND TVSS FROM SUNCOAST ENVIRONMENTAL, INC. CONTACT : SCOTT DYER (877)544-6679. NO SUBSTITUTIONS ALLOWED. 2. PURCHASE T-500 LIGHTING CONTROL PANEL FROM SUNCOAST ENVIRONMENTAL, INC. NO SUBSTITUTIONS ALLOWED. ALL EQUIPMENT IN THE CONTROL PANEL SHALL BE INSTALLED, WIRED AND CONNECTED AT THE FACTORY. 3. CONTRACTOR SHALL PROVIDE PANEL FEEDERS A, B, C, D AND POS; BRANCH CIRCUIT CONDUIT AND WIRE; AND SHALL INSTALL ALL EQUIPMENT AS REQUIRED. 4. ALL BREAKERS AND PANELS SHALL BE SIEMANS AS DESIGNED AND FURNISHED THRU SUNCOAST ENVIRONMENTAL, INC. NO SUBSTITUTIONS ALLOWED. 5. TVSS AND SURGE ARRESTOR UNITS SHALL BE MOUNTED DIRECTLY ADJACENT TO THE SIDE OF THE MAIN DISTRIBUTION PANEL IN NEMA 3R ENCLOSURES. CLOSE NIPPLE THE UNITS TO THE SIDE OF THE PANEL. PROVIDE CONNECTION OF TVSS UNIT TO BREAKER IN PANEL. CONNECT SURGE ARRESTOR TO MAIN INCOMING LUGS OF THE PANEL. CONNECT USING MINIMUM LENGTH OF WIRE WITHOUT SHARP BENDS IN THE WIRE AND SHALL NOT BE LENGTHENED FROM WIRE LENGTH PROVIDED WITH THE TVSS OR SURGE SUPPRESSOR DEVICE. 1/2" = 1'-0" RECEIVED CITY OF TUK WILA NOV 21 2017 PERMIT CENTER C 0 Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 co A Co 1411110 V Information contained on this drawing and in all digital files 4111) produced for above named project may not be reproduced in any manner without express written or verbal consent from 11111111111 authorized project representatives. 0 SHEET �. SINGLE LINE DIAGRAM 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC DEC 13 2017 City of .Tukwila BUILDING DIVISION ARCHITECTS PROJECT # #'ll'!" PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer AND NOTES SHEET NUMBER E-502 11/9/2017 5:11:48 PM E SECTION C16100 ELECTRICAL GENERAL PROVISIONS PART 1- GENERAL 1.01 WORK INCLUDED A. Provide all materials, labor and equipment required to furnish and install a complete electrical system as indicated on drawings and as specified herein. 1.02 REGULATORY REQUIREMENTS A. Equipment furnished shall be UL listed where such label is available. Installation shall conform to UL standards where applicable. B. Electrical work shall be installed in accordance with drawings and specifications, NEC and NFPA codes in effect at project location, state and local electrical and building codes and special codes having jurisdiction over specific portions within complete installation. Obtain permits and certificates of approval from all authorities having jurisdiction over the installation and pay all fees required. 1.03 SUBMITTALS A. Submit list of materials and equipment prior to manufacture, order or installation and within twenty days after award of contract for approval. Include each item of material and equipment whether or not shop drawings are also required. List shall include name of manufacturer, catalog number and other complete identification as well as dimensions and detailed data. Submittals shall included for the following: p 1. Lighting Fixtures 2. Panelboards/Breakers 3. Wiring Devices and Device Plates 4. Enclosed Switches C B. Certified shop drawings and submittals shall bear stamp of approval of contractor as evidence that drawings have been checked. Drawings submitted without this stamp of approval will not be considered and will be returned for proper resubmission. C. If submittals show variances or substitutions from requirements of contract, contractor shall make specific mention of such variation in his letter of transmittal in order that, if acceptable, suitable action may be taken for proper adjustment. Otherwise contractor shall not be relieved of responsibility for executing work in accordance with contract even though such submittals have been approved. 1.04 SITE VISIT A. Visit job site prior to bid date to determine actual conditions under which work shall be done, to familiarize oneself with project and to verify total scope of work required. Failure to do so shall not constitute a reason for an extra charge. SECTION C16101 BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.01 COORDINATION A. Obtain and review shop drawings, product data, and manufacturer's instructions for equipment furnished under other sections to determine connection locations and requirements. B. Sequence rough -in of electrical connections to coordinate with installation and start-up of equipment furnished under other sections. PART 2 - PRODUCTS 2.01 SUBSTITUTIONS A. Where specifications list one or more manufacturers and do not include "or approved equal", furnish materials made by one of manufacturers listed. Where "or approved equal" is included, contractor may substitute equal products by another manufacturer subject to approval by engineer and owner. PART 3 - EXECUTION 3.01 INSTALLATION A. Make electrical connections to utilization equipment in accordance with equipment manufacturer's instructions. B. Drawings are diagramatic and shall not be scaled for exact sizes or locations, they are not intended to disclose absolute or unconditional knowledge of actual field conditions. C. Protect work and materials from damage by weather, entrance of water and dirt. cap conduit during installation. Avoid damage to materials and B equipment in place. A D. Satisfactorily repair or remove and replace damaged work with new materials. Deliver equipment and materials to job site in original, unopened, labeled containers. Store ferrous materials to prevent rusting. Store finished materials and equipment to prevent staining and discoloring. E. Trenches shall be excavated 6" below elevation of bottom of conduit. F. Failure to route conduit through building without interfering with other equipment and construction shall not constitute a reason for an extra. charge. Equipment, conduit and fixtures shall fit into available spaces in building and shall not be introduced into building at such times and manner as to cause damage to structure. Equipment requiring service shall be readily accessible. 3.02 TESTING AND EQUIPMENT SERVICING A. Make test to ensure that entire system is in proper operating condition, and that adjustments and apparatus setting of circuit breakers, fuses, control equipment and apparatus have been made. Correct defects discovered during tests. 3.03 REMOVAL OF DEBRIS A. Remove surplus materials and debris caused by, or incidental to, electrical worK. Remove such debris at frequent intervals. Keep job clean during construction. 3.04 IDENTIFICATION OF EQUIPMENT A. Identify electrical distribution equipment, disconnects, and contactors with black laminated plastic name -plates, attached with two screws, engraved with 1/4" high, white letters. 3.05 TEMPORARY LIGHTING AND POWER IN AREAS OF CONSTRUCTION A. Provide, maintain and remove after construction is completed, temporary lighting adequate for workman safety and temporary power for all trades including any 3 phase power required. B. Provide and maintain barricade lighting where required to adequately protect owner against liability for damage to public or personnel. All lamps used in barricade shall be 60 watt red, installed in weatherproof socket with wire guard. All wiring shall be approved for weatherproof installation. 3.06 GUARANTEE -WARRANTY A. Guarantee work to be free from defects of materials and workmanship for a period of one year from date of final acceptance of building. Repair and replace defective work and other work damaged thereby which becomes defective during term of guarantee -warranty. Furnish owner with three written copies of guarantee -warranty. SECTION C16120 RACEWAYS AND CONDUIT SYSTEMS PART 1 - PRODUCTS 1.01 ACCEPTABLE MANUFACTURERS A. Rigid IMC, and EMT conduit shall be hot -dipped, galvanized, or electro -galvanized steel by Allied, Republic, Triangle, Wheatland, or approved equal. B. PVC conduit shall be Carlon, schedule 40, 90 degrees C. rated, unless otherwise noted. C. MC cable shall be manufactured by AFC Cable Systems or approved equal. Type "AC -90" is not allowed. All MC Cables shall have a green equipment ground conductor and and isolated ground (green + yellow stripe) conductor. Cables for data systems power circuits shall be as specified on plans. D. Associated couplings, connectors and fittings shall be steel as manufactured by Raco or equivalent. Catalog numbers used below are those of Raco. E. Erickson Couplings, Series 1502, shall be used where neither length of conduit can be rotated. F. Insulated bushings shall be series 1402. G. EMT box connectors shall be compression fittings. H. Conduit, connectors, couplings and fittings shall be UL listed and labeled. 1.02 ELECTRICAL METALLIC TUBING (EMT) A. Use Electrical Metallic Tubing (EMT) where drawings call for conduit to be: 1. Concealed in walls. 2. Installed above suspended ceilings. 3. Installed exposed, above 6 feet. 1.03 INTERMEDIATE METAL CONDUIT (IMC) A. Use Intermediate Metal Conduit (IMC) where drawings call for conduit to be: 1. Installed for panelboard feeders. 2. Installed in wet locations (interior and exterior). 3. Installed exposed below 6 feet. 1.04 POLYVINYL CHLORIDE (PVC) RACEWAY A. Use PVC raceway for: 1. Underground service entrance conduits for telephone and power. 2. Exterior branch circuits installed underground. 3. Interior branch circuit conduits installed in or under concrete slab on ground floor. 1.05 RIGID STEEL CONDUIT (RSC) A. Use Rigid Steel Conduit for: 1. Install underground for power Service Entrance elbows penetrating floor slab. 2. Exposed to physical damage. 1.06 FLEXIBLE METAL CONDUIT A. Provide flexible metal conduit for termination at equipment subject to motion and vibration. B. Length shall not exceed 6 feet in accessible ceiling areas. C. Shall not be concealed in walls. D. Where exposed to continuous or intermittent moisture, conduit shall be UL Type EF liquidtight or type as indicated. E. For connection to ceiling mounted lighting fixtures from outlet boxes. 1.07 MC (METAL -CLAD) CABLE A. MC Cable may be used, concealed above ceiling and in walls, when allowed by local codes and article 330 of the national electrical code for the connection of the Point Of Sales (POS) system equipment only. MC Cable with an isolated grounding conductor shall be used, concealed above the ceiling and in walls, for the connection of the Point of Sales (POS) system equipment from the isolated ground receptacle to the panelboard serving the POS loads when allowed by local codes and Article 330 of the National Electrical Code. C. MC Cable may be used when allowed by local codes and Article 330 of the National Electrical Code for branch circuits (except the main homerun to the panelboard, which shall be conduit and conductors), for the following: 1. Lighting. 2. Dining area receptacles. 3. Fly lights. 4. Building mounted signage. 5. Office area receptacles. D. MC Cable shall not be used for branch circuits serving kitchen equipment items and similar circuits in the kitchen, the drive-thru area, and the serving area's back counter PART 2 - EXECUTION 2.01 INSTALLATION A. Minimum size of conduits shall be 1/2 inch. B. Run concealed conduits in direct line with long sweep bends or offsets. Run exposed conduits parallel to and at right angles to building lines. Group multiple conduit runs in banks. C. Cap ends of conduits to prevent entrance of water and other foreign material during construction. D. Provide No. 12 AWG copper pull wires or nylon cord in all empty conduits. Steel wire not acceptable as pull wire. E. Where IMC enters a cabinet, junction box, or pull box conductors shall be protected by an insulated bushing. Locknuts shall be installed on conduit outside and inside enclosure. F. In areas where enclosed and gasketed fixtures and weatherproof devices are specified, where Rigid Conduit enters a sheet metal enclosure, junction box and outlet box, and not terminated in a threaded hub, a steel, or malleable iron nylon insulated hub, complete with recessed sealing "0" ring or sealing locknut shall be used. G. Provide seal -off fitting in all conduits entering a cold temperature area such as freezers and dry refrigerators. H. In concrete slabs, block up conduit from forms and securely fasten in place. all conduits in slabs shall have a minimum of 4" inches concrete coverage above. Failure to route conduit through building without interfering with other equipment, and construction shall not constitute a reason for an extra charge. Equipment, conduit, and fixtures shall fit into available spaces in building and shall not be introduced into building at such times and manner as to cause damage to structure or equipment. Equipment requiring servicing shall be readily accessible. 2.02 EMT (ELECTRICAL METALLIC TUBING) RACEWAY A. Do not use Electrical Metallic Tubing in cinder concrete or cinder fill or where conduit system is in contact with dissimilar metals or in wet locations. 2.03 PVC RACEWAY A. Use threaded fittings for all connectors and adapters. E. Provide 1/4 -inch nylon pull rope in all primary power and incoming telephone service entrance conduits. F. PVC conduit shall convert to galvanized rigid metal per detail on drawings. 2.04 FLEXIBLE METAL CONDUIT A. Where fittings for liquid tight flexible conduit are brought into an enclosure with a knock -out, a gasket assembly, consisting of one piece "0" ring, with Buna-N sealing materiaL, series 3400, shall be installed on outside of box. Fittings shall be made of either steel or malleable iron only, and shall have insulated throats or insulated bushings. B. In dry locations, where final connections to motors and other equipment may be made with Flexible Metal Conduit, fittings shall be of steel or malleable iron only with insulated throats or insulated bushings, and shall be of wedge and screw type having an angular wedge fitting between convolutions of conduit. 2.05 MC Cable A. MC Cable may be used for branch circuits as noted in Part 1 above and where the local code allows use of MC Cable. The installation shall conform to Article 330 of the National Electrical Code and shall be concealed in walls and above ceiling. (Exposed MC Cable shall not be allowed). B. MC Cables shall be secured and supported by the building structure per the National Electrical Code and any local code requirements. MC Cable shall not lay on ceilings. SECTION C16121 CONDUCTORS PART 1 - PRODUCTS 1.01 CONDUCTORS A. Provide 98% conductivity copper conductors with 600 -volt insulation. For conductors No. 12 AWG and No. 10 AWG, provide solid type. For all conductors No. 8 AWG and larger, provide stranded type. All conductors shall have THHN/THWN insulation unless noted otherwise. B. Conductors shall be manufactured by Triangle, American, Rome, Southwire or approved equal. C. Provide No. 14 AWG type THHN fixture conductors, for conductors entering lighting fixtures. D. Branch circuit conductors shall be minimum #12 AWG, copper. PART 2 - EXECUTION 2.01 INSTALLATION A. Install pull boxes in circuits or feeders over 100 feet long. B. Make all splices or connections only at outlet, pull or junction boxes. C. All conductors and connections shall test free of grounds, shorts, and opens prior to energizing circuit. D. Provide No. 10 wire in lieu of No. 12 wire for any branch circuit in excess of 100 feet linear length to prevent excessive voltage drop. E. Use Ideal wing nuts, Scotchlok Type Y, R, G, or B, or approved equivalent connectors for fixture connections at outlet boxes. F. Make feeder taps and joints with OZ Type T, PT, PM or PTS, or approved equivalent clamp connectors as manufactured by Kupler, or with approved compression sleeves. Wrap connectors with No. 10 Electro -Seal or approved equivalent plastic filler and vinyl tape. G. Leave a minimum of 8" slack wire in every outlet box. H. Provide color coded wire and with a different color for each phase and neutral and ground as follows: Phase A, B, C: Black, Red and Blue respectively; Neutral: White; Isolated Ground: Green with Yellow Stripes. Approved color tape is acceptable for feeders using larger than #6 conductors. All conductors shall be continuous from origin to panel or equipment termination without splices where possible. Where splices and taps are necessary or are required, they shall be made in splice boxes with suitable connectors. J. Tighten all electrical connectors and terminals, including screws and bolts, in accordance with manufacturer's published torque tightening values. Where manufacturer's torquing requirements are not indicated, tighten connectors and terminals to comply with tightening torques specified in UL486A and UL486B. SECTION C16122 OUTLET AND JUNCTION BOXES PART 1 - GENERAL 1.01 PROJECT CONDITIONS A. Verify field measurements are as shown on drawings. B. Verify locations of floor boxes and outlets in work areas prior to rough -in. PART 2 - PRODUCTS 2.01 OUTLET BOXES A. Sheet metal outlet boxes: galvanized steel. B. Cast boxes: type FS, cast feralloy. Provide gasketed cover by box manufacturer. C. Manufacturers: National, Appleton, General Electric, RACO, OR Steel City. D. Provide boxes for fixtures with fixture studs in center. E. Outlet boxes for lighting, switches and receptacles in interior areas with exposed conduit shall be pressed steel and in exterior areas with exposed conduit shall be cast metal with threaded hubs, "FS" type. Use galvanized steel for concealed boxes. Boxes shall be 1-1/2" deep minimum. 2.02 PULL AND JUNCTION BOXES A. Sheet metal boxes: galvanized steel. B. Surface -mounted cast metal box: type 4; flat -flanged, surface -mounted junction box. 1. Material: galvanized cast iron. 2. Cover: furnish with ground flange, neoprene gasket, and stainless steel cover screws. C. In -ground cast metal box: inside flanged, recessed cover box for flush mounting. 1. Material: galvanized cast iron. 2. Cover: nonskid cover with neoprene gasket and stainless steel cover screws. 3. Cover legend: electric. D. Manufacturers: National, Appleton, General Electric, RACO, Oz -Gedney or Steel City. PART 3 - EXECUTION 3.01 INSTALLATION A. Install electrical boxes as shown on drawings, and as required for splices, taps, wire pulling, equipment connections and compliance with regulatory requirements. B. Install pull boxes and junction boxes above accessible ceilings. C. Inaccessible ceiling areas: Install outlet and junction boxes no more than 6 inches from ceiling access panel or from removable recessed light fixture. D. Use flush mounting outlet boxes in finished areas. E. F. Use stamped steel bridges to fasten flush mounting outlet box between studs. Install flush mounted box without damaging wall insulation or reducing its effectiveness. G. Use adjustable steel channel fasteners for hung ceiling outlet box. H. Do not fasten boxes to ceiling support wires. I. Support boxes independently of conduit, except cast box that is connected to two Rigid Metal Conduits both supported within 12 inches of box. J. Use gang box where more than one device is mounted together. Do not use sectional box. K. Use gang box with plaster ring for single device outlets. L. Use cast outlet box in exterior locations and wet locations. 3.02 OUTLET BOXES A. Select boxes according to intended use and type of outlet. Ceiling outlet boxes shall be 4" octagon and 1-1/2" deep. Use 2-1/8" deep octagon boxes or 4" square boxes required. All ceiling outlet boxes shall have a fixture stud of no bolt self-locking type installed if required to hang the fixture specified at the outlet. 3.03 JUNCTION BOXES A. Junction boxes shall be sized according to number of conductors in box or type of service to be provided. Minimum junction box size 4-11/16" square and 2-1/8" deep. Provide screw covers for junction boxes. B. Use code gauge steel with screw covers for pull boxes with prime coat and provide with screw cover. Size pull boxes according to the NEC. C. Provide pull box every 100 feet of conduit run or where excessive number of bends necessitates a box for ease of wire installation. SECTION C16123 GROUNDING AND BONDING PART 1 - PRODUCTS 1.01 ROD ELECTRODES A. Material: copper -clad steel. B. Diameter: 3/4 inch. C. Length: 10 feet. 1.02 MECHANICAL CONNECTORS A. Material: bronze. 1.03 GROUNDING CONDUCTOR (WIRE) A. Material: stranded copper, sized to meet NFPA 70, Article 250 requirements. PART 2 - EXECUTION 2.01 INSTALLATION A. Install rod electrodes at locations indicated. Install additional rod electrodes as required to achieve resistance to ground of less than 25 ohms. B. Provide grounding electrode conductor and connect to reinforcing steel in foundation footing. C. Provide bonding to meet regulatory requirements. D. Bond together each metallic raceway, pipe, duct and other metal objects. E. Provide isolated grounding conductor for circuits supplying all isolated ground outlets. Insulation shall be green with yellow stripe. Size per NEC Table 250.66. This isolated grounding conductor shall run in addition to equipment grounding conductor and along with the branch circuit conductors. 2.02 GROUNDING A. Ground electrical system in accordance with NEC Article 250 and local authorities having jurisdiction. B. Install a #3/0 bare copper wire bond across the water meter attached to ground clamps on water line on each side of meter. Arrangements shall be made to do this work at the time the water meter is installed. C. From the point of entrance of the water main into the building and on the meter side of the main inside water valve and union install a stranded copper cable #3/0 in 1-1/4" conduit to the main distribution panel. Connect the cable to the equipment ground bus. D. Install a green equipment grounding conductor in each raceway, sized per NEC Table 250-122. Terminate on equipment ground bus within panelboard serving load. E. Install #6 awg copper grounding conductor from ground bar in main telephone box to grounded neutral bus in main distribution panel. F. All separate grounding electrode conductors shall be bonded together to limit potential differences between them and between their associated wiring systems. This includes the power system, telephone system, etc. 2.03 FIELD QUALITY CONTROL A. Inspect grounding and bonding system conductors and connections for tightness and proper installation. RECEIVED CITY OF TUKWiLA NOV 21 2017 PERMIT CENTER D C B • Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECTS PROJECT # PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET ELECTRICAL SPECIFICATIONS SHEET NUMBER E-901 11/9/2017 5:12:19 PM E D C B SECTION C16124 SUPPORTING DEVICES AND HANGERS PART 1 - PRODUCTS 1.01 ACCEPTABLE MANUFACTURERS A. Supporting devices and hangers shall be manufactured by RACO Fasteners, or approved equivalent. PART 2 - EXECUTION 2.01 INSTALLATION A. Secure conduits to within 3' of each outlet box, junction box, cabinet, fitting, etc., and at intervals not to exceed ten feet (10') and in accordance with the National Electric Code. In seismic zones, support conduits 1" and under at 6' intervals. B. Install clamps secured to structure for feeder and other conduits routed against the structure. Use drop rods and hangers or racks to support conduits run apart from the structure. C. Provide and install suitable angle iron, channel iron or steel metal framing with accessories to support or brace electrical equipment including safety switches, fixtures, panelboards, etc. D. Use of chains, perforated iron, baling wire, or tie wire for supporting conduit runs is not permitted. E. For support of low voltage wiring not required to be in conduit, bundle cables together in a neat manner using approved nylon tie wraps. Bundled cables shall be supported with "J" hooks on telephone type bridle rings, a minimum of 6 feet on centers. Clearly identify all differing types of cables being run and tag with tape tags regarding telephone, POS System, music/communication, security, etc. for various system utilizing said cable. Identification tape shall be provided at minimum intervals of 25 feet on center and within each space. building F. Provide a system of supporting devices and hangers to insure secure support or bracing for conduit, electrical equipment, including safety switches, fixtures, panelboards, outlet boxes, junction boxes, cabinets, etc. SECTION C16140 WIRING DEVICES AND PLATES PART 1 - PRODUCTS 1.01 WALL SWITCHES A. Shall be purchased from the National Accounts Vendor indicated on the plans. B. Ratings: 20 amps, 120/277 volts a.c. or as identified on drawings. C. Devices: (Cooper/Arrow Hart catalog numbers are listed unless noted otherwise): 1.Single pole toggle switches: 20 AMP device - #AH1221-GY (Kitchen) or #AH1221-B (Dining) 20 AMP Pilot lights illuminated with load on - #AH1221-PL 2.Double pole toggle switches: 20 AMP device - #AH1222-GY (Kitchen) or #AH1222-B (Dining) 1.02 RECEPTACLES A. Shall be purchased from the National Accounts Vendor indicated on the plans. B. Devices: (Cooper/Arrow Hart catalog numbers are listed unless otherwise noted): 1. Specification grade devices (grey device color in Kitchen, brown device color in Dining, and orange for IG type) to be 20 amp, 125 volts, a.c. receptacles: Single (simplex) device: #1877-GY (Kit) or #1877-B (Dining) Duplex device: #CR20-GY (Kitchen) of #CR20-B (Dining) Tamper resistant duplex device: #TR8200-B (Dining) GF (ground - fault circuit interrupter) duplex device: #VGF20-GY (Kitchen) or #VGF20-B (Dining) IG (isolated ground) duplex device: #IG5362-RN (orange face) 1.03 SPECIAL DEVICES A. Manual motor starter switch: SQ. D Class 2510, Type F, for use on motors up to 3/4 horsepower. Provide NEMA 1 enclosure in dry locations; provide NEMA 3R enclosure in wet exterior locations. 1.04 WALL PLATES A. Provide Cooper/Arrow Hart, or approved equal, smooth satin stainless steel 302 -SS series for switches and receptacles in the Kitchen areas. All other areas shall be brown Nylon plastic. B. Provide blank plates on all outlet boxes for future outlets, or outlets without devices. Plate style shall match device plates. C. Provide non-metallic weatherproof covers for duplex GF receptacles located outside or in wet locations that feature 'while -in -use' cover equivalent to Arrow Hart #WIU-1. D. Where devices installed in exposed boxes or conduit fittings; provide properly designed plates and covers equal to Arrow Hart RS -Series exposed work covers. E. Install galvanized steel plates on outlet boxes and junction boxes in unfinished areas, above accessible ceilings, and on surface mounted boxes. PART 2 - EXECUTION 2.01 INSTALLATION A. Mounting 1. Mount switches and receptacles at height above finished floor as indicated on plans, and legend. 2. Mount switches on strike side of door maximum 8" from door frame. Outlet box for switch shall be located clear of door frame. Coordinate with architectural plans prior to rough -in. 3. Install switches with off position down. 4. Do not use the feed thru feature for the GF Type receptacle, unless required by the plans. 5. Use jumbo sized plates for outlets installed in masonry walls. 6. Each receptacle shall be provided with a #12 green grounding jumper between the ground terminal of the receptacle and the outlet box. 7. The grounding conductor to each receptacle shall be installed such that the removal of the device will not interfere with the continuity of the ground. B. Testing 1. Test each switch and verify proper operation with energized circuit. 2. Test each receptacle for proper polarity on energized circuit. 3. Test each GF receptacle with a GF receptacle tester and verify the circuit is opened by GF device at milli -ampere ranges established by manufacturer. SECTION C16440 PANELBOARDS PART 1 - PRODUCTS 1.01 MANUFACTURER A. Suncoast Environmental Controls (SEC) thru a National Accounts Program 1.02 PANELBOARD FEATURES A. Panelboards shall have a minimum symmetrical interrupting rating to meet or exceed the available symmetrical interrupting fault current at the device intended to interrupt current. B. Bus bars shall be copper or tin plated aluminum. C. Provide factory -installed copper ground bus in each panelboard with Tugs or connectors on bar. D. 1.02 ENCLOSED SWITCHES A. Nonfusible switch assemblies: NEMA KS 1, General Duty Type for 208 volt load interrupter enclosed knife switch with externally operable handle interlocked to prevent opening front cover with switch in on position. E. Handle lockable in off position. Provide equipment ground lug in each switch. B. Enclosures: NEMA KS 1. 1. Interior dry locations: Type 1. 2. Exterior locations: Type 3R. F. G. SECTION C16442 UTILITY SERVICE ENTRANCE AND DISTRIBUTION SYSTEM H. PART 1 - GENERAL 1.01 SYSTEM DESCRIPTION A. The underground electrical system service characteristics shall be 208Y/120 volts, Three Phase, Four Wire service and shall extend from utility company transformer secondary. B. Metering of electrical usage shall be located as required by local electrical utility company. Coordinate requirements with local utility company. C. Distribution system originates at secondary of utility transformer and includes service entrance conduit and conductors, distribution equipment, lighting panelboards, utilization equipment, overcurrent devices, disconnecting means, controls, branch and feeder circuits, etc. PART 2 - PRODUCTS 2.01 MATERIALS A. PART 3.01 D. Provide electrically isolated, factory installed, neutral bus in each 3 A. phase, 4 wire or 1 phase 3 wire panelboard. E. In addition to the ground bus required by paragraph 1.02D (above), provide factory installed, electrically isolated, copper ground bus in each panelboard serving isolated ground receptacles. B. F. Main lugs and main circuit breaker lugs shall be UL Listed for use C. with both aluminum and copper conductors. G. Provide panelboard doors with chrome -plated locks and catches. All locks shall be keyed alike. Provide two keys for each lock. H. Provide thermal -magnetic circuit breakers which are rated for 40 degrees C ambient temperature. Breakers shall be quick -make, quick - break type trip with trip indication shown by handle position other than on or off. Multi -pole breakers shall have a common trip handle. Tandem type circuit breakers shall not be permitted. Provide typed directory card with clear holder for each panelboard. PART 2 - EXECUTION 2.01 INSTALLATION A. Panelboards shall be mounted at height above finished floor such that the height of the top -most breaker in the panel is not more than 6-1/2 feet above finished floor in its highest position per the NEC. B. Where multiple panelboards are installed on walls in common areas of buildings, the panelboards shall be installed with the top of all panelboards at the same height. C. Provide blank filler plates over all unused spaces in panelboards. D. A typed directory card shall indicate devices being served and the space name where the device is located. E. Provide minimum of one (1) 3/4" empty spare conduit for every 3 poles of spare breaker or space in the panelboard. Stub conduit to nearest accessible ceiling space. Label conduit as spare at panelboard and termination point. F. Non -isolated ground bars shall be grounded to panelboard can and main service entrance ground bus with a code sized grounding conductor or installed in the same conduit as the phase and neutral conductors. G. Circuits using a common neutral shall be installed in accordance with the National Electrical Code. H. Inspect each panelboard for proper installation, physical damage, tightness and installation of overcurrent devices. Verify proper color coding of conductors. Correct or repair all items found in inspection. I. Neutral wires, ground wires, and isolated ground wires shall be connected to the appropriate panel bus bar. Do not mix bus wire connections. SECTION C16441 ENCLOSED SWITCHES PART 1 - PRODUCTS 1.01 MANUFACTURERS A. Square D. B. General Electric. C. Siemens D. E. F. Furnish service entrance conduit, cable, and miscellaneous hardware as required by plans and specifications for electrical service entrance and system grounding at main electrical service. 3 - EXECUTION EXAMINATION AND PREPARATION Coordinate exact locations of electrical service utility transformer, metering equipment, service lateral, etc. prior to commencement of installation. Contact engineer with conflicts prior to bid. Ensure pad mounted transformer is not located within roadway or sidewalk. Coordinate with local electrical utility for all utility company requirements and provide for the following items and any others required by the utility: 1. Concrete pad for utility transformer with required dimensions and details. 2. Primary underground conduit, excavation, and backfill requirements. 3. Pay for all fees associated with establishment of electrical service. 4. Furnish list of loads to the electrical utility company serving the facility. 5. Verify that utility company clearances are provided on all sides of utility equipment. Ensure proper access to utility equipment is maintained. Provide pull rope, excavation in accordance with electrical utility company requirements, backfill and concrete envelope for primary in accordance with electrical utility company requirements. Turn conduits up riser pole as required. cap spare conduits 12 inches above grade with plumbers pipe cap. Provide secondary lugs on utility transformer and perform drilling and installation of lugs in accordance with utility requirements. Type of lugs shall be in accordance with electrical utility company requirements. Connect service conductor to transformer secondary lugs as directed by electrical utility. SECTION C16500 LIGHTING FIXTURES (LUMINAIRES) PART 1 - GENERAL 1.01 ACCEPTABLE MANUFACTURERS AND VENDORS A. Lighting fixtures indicated on lighting fixture schedule are to be purchased from the National Account Vendor for the region of the project (verify region designation with Owner's Representative): 1. Accu-Sery Lighting - North region and Southeast region. Contact at Accu-Serv: Bob Harpring at 877-707-7378, fax - 502-961-0357, email - bharpring@accu-serv.com 2. Villa Lighting - Central region, Southwest region, and West region. Contact at Villa Lighting: Dave Christanell at 800-325-0963, fax - 314-531-8720, email - davec@villalighting.com B. C. Ballasts to be electronic ballast provided with lighting fixture by the manufacturer. Lamps to be Osram-Sylvania and will typically be provided with the luminaire by the lighting manufacturer. 1.02 FIXTURE REQUIREMENTS A. Provide regulating, HPF ballasts in all HID lighting fixtures. HID lamp types shall be as indicated on the drawings. B. Recessed fluorescent lighting fixture ballasts shall be provided with integral thermal protection. C. Provide energy-saving Instant or Rapid Start lamps for all fluorescent fixtures. All lamps and ballasts shall meet or exceed the requirements of the National Energy Policy Act of 1992 and any other applicable Codes or Criteria. All components of recessed fixtures shall be accessible without disturbing fixture in or on ceiling. Energy saving ballasts and energy saving lamps provided shall be compatable for operation together. Exterior fixtures and poles shall be suitable for exterior use, shall be UL Listed, and shall be a standard design for exterior application. Exterior poles for fixtures with luminaires installed shall be designed for maximum constant velocity wind load with luminaires installed, applicable to the geographic area. 1.03 CONTROLS A. Lighting control system shall be Acuity Brands LC&D Sensor Switch as specified on drawings. B. Lighting contactors shall be Square -D, General Electric, Cutler- Hammer or Siemens of types and quantity shown on drawings, except those furnished with the switchgear as part of the National Account Program by Suncoast Environmental Controls (SEC). 1.04 EMERGENCY LIGHTING UNITS A. Batteries shall supply emergency power for lighting with minimum operating time of 1-1/2 hours. B. Emergency lighting shall be automatically operational upon normal utility power failure. PART 3 - EXECUTION 3.01 INSTALLATION A. Lighting fixtures shall be structurally supported. Fluorescent fixtures mounted in suspended ceilings shall be supported by and attached to ceiling system as required by NEC Article 410. In addition, fluorescent troffers shall be supported at two opposite corners to building structure. B. Recessed fixtures in dropped ceiling areas shall be connected to power source using flexible conduit. Flexible conduit shall contain a separate insulated green No. 12 copper ground wire. Flexible conduit shall be connected to junction box and fixture. Green ground wire shall provide ground continuity between conduit system and fixture. Grounding conductors shall be permanently and mechanically connected between fixture and conduit system so as to be electrically continuous. C. Fixtures surface mounted on exposed tee bar ceilings shall use grip clamps on tee bars to support fixtures. D. Wire shall be continuous from splice in outlet box of building wiring system to lamp socket or ballast terminals. E. Maintain the integrity of enclosures on enclosed and gasketed fixtures. Minimize the number of enclosure penetrations and make such penetrations water and dust tight with appropriate gaskets and fittings. F. Concrete bases shall be provided for all exterior ground mounted or pole mounted fixtures. G. H. Install accessories furnished with each fixture. Wiring from pole bases to pole mounted luminaire shall be No. 12 with fuse protection provided by a 30 amp, 600 volt waterproof fuseholder with Bussman 'Limitron' fuse of ampere rating 3 times the load current. Surface and recessed fixtures on or in plastered or drywall ceilings shall be supported by support channels. Support channels shall span across main support channels and shall not depend upon ceilings for support. 3.02 FIELD QUALITY CONTROL A. Relamp fixtures that have failed lamps at substantial completion. SECTION C16596 SPECIAL SYSTEMS PART 1 - GENERAL 1.01 WORK INCLUDED A. Furnish and install raceway system for music/communications security, CCTV, POS, and other owner - furnished systems, consisting of empty conduits, junction boxes, outlet boxes, and device plates, etc., as specified and shown on owner selected vendor wiring schematics. Cable, equipment, and installation of the interior system will be provided by the owner's system vendor. B. Interior system equipment will be furnished by Owner's Vendor. C. Install special backboxes furnished by Owner's Vendor. Coordinate with the Vendor for the installation. Coordinate with the Vendor if backboxes are to be contractor provided in order to provide and install the appropriate item for the Vendor. PART 2 - PRODUCTS 2.01 MATERIALS A. Provide 4-11/16" square boxes, with plaster rings. Provide device plates for system outlets as specified in Section 16141. Provide separate conduit to nearest accessible ceiling space from each outlet. B. Cable shall be in conduit where installed in walls or inaccessible ceilings. C. Minimum conduit size shall be 3/4" . PART 3 - EXECUTION 3.01 INSTALLATION A. Furnish and install conduits, junction boxes, outlet boxes, and plates. B. Provide one #10 equivalent nylon pull wire in each system empty conduit. C. Provide a complete raceway system in accordance with interior system vendor requirements. Interior system vendor shall review the drawings. Contractor shall provide for any additional or varying requirements. D. Final connections and testing of systems will be provided by the system vendor. Contractor shall contact the owner's vendor and schedule the work so as to complete system installation and testing prior to occupancy of the facility. E. Terminate each conduit stub -up or termination with nylon insulated bushing. SECTION C16597 TELEPHONE SERVICE PART 1 - GENERAL 1.01 WORK INCLUDED A. Furnish and install telephone system consisting of empty conduits, junction boxes, outlet boxes, device plates, etc., as specified and shown on owner selected vendor wiring schematics. Cable, equipment, and installation of the interior system will be provided by the owner's system vendor. B. Provide underground PVC, Schedule 40, service conduit as required by plans. C. Telephone Utility Company will provide service entrance cable. D. Interior telephone system will be furnished by owner's vendor. E. Special backboxes (unless otherwise noted) and faceplates will be furnished by the owner's vendor. PART 2 - PRODUCTS 2.01 MATERIALS A. Provide 4-11/16" square boxes, with plaster rings. Provide device plates for telephone outlets to match those specified in wiring device section. Provide separate conduit to nearest accessible ceiling space from each outlet. B. Minimum conduit size shall be 3/4". C. Provide lightning arrester for telephone service entrance at main telephone backboard in accordance with UL96A paragraph 11.2 and NFPA 780. D. Cable shall be in conduit where installed in walls or above inaccessible ceiling spaces. PART 3 - EXECUTION 3.01 INSTALLATION A. Provide one #10 equivalent nylon pull wire in each empty telephone conduit. B. Provide trenching, backfilling, etc., for installation of service entrance conduit in accordance with other divisions, plans, and telephone utility requirements. Provide pull wire in empty conduit. C. Coordinate with the local utility for point of service and type of service required. Pay for any utility company charges and fees for establishment of service. D. Provide a complete raceway system in accordance with telephone utility company and interior system vendor/utility requirements. Telephone utility company and interior system vendor shall review the drawings. Contractor shall provide for any additional or varying requirements. E. Terminate each conduit stub -up or termination with nylon insulated bushings. F. Final connections and testing of system will be provided by the system vendor. Contractor shall contact the owner and vendor and schedule the work. CLOSE OUT DOCUMENT REQUIREMENTS Provide the following to the building owner upon completion of construction: 1. Submittal data stating equipment rating and selected options for each piece of equipment requiring maintenance. 2. Operation manuals and maintenance manuals for each piece of equipment requiring maintenance. Required routine maintenance actions shall be clearly identified. 3. Names and addresses of at least one qualified service agency. 4. A complete narrative of how each system is intended to operate. RECE'1l1:71 CITY OF TUKWILe NOV 21 2011 PERMIT CENTER E D C Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349- 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 UNIN 1 CI) B v 0 CO Op imma °' FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 0 NEC DEC 13 ?1117 City of Tukwila BUILDING DIVISION ARCHITECTS PROJECT # MAW A PRINTED FOR Project Status DATE Issue Date (40 N iami Cm) ■ q 0 SHEET a ELECTRICAL 0. SPECIFICATIONS DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET NUMBER E-902 11/9/2017 5:12:35 PM E D C B A interior Dis la. Ligh n:..9 Sace-b SP. ace ea �? Y LTG -INT -DISPLAY 2015 Washin ton State Ener 'CodeCom fiance Farrns:for:Commercial Buildlti indudiri , R3 R4over3 stories 9 9y P Bs 9 R2, , nd all R1 Revised Au st20t6:. Protect Title; Chick=fit=A 04094:17333 SouthcenterPkwy, Tukwila; WA. Date 711/2016: •General`IJote - In'•Sates areas, an increase inlighting pours alfouence is permitted fru lighting installed spec callyforthe'purposeofhighlightingmerchandise..OnlySelesareasifluminatedtvfh eligible, merchanrsedrsptaylighting maybe rncludedin fhe;Gross. lnterior Area•yndereach Retail category. This lightingpower' ailawanCe•is the Maximum Rete (DisplayABowenre OR the Fatal Retail Proposed DisplayWatts,ithiciiever is Iess. Proposed retail dfsplaylighting aeftage: fliat.exceedsihis allmence is applied togeneral area lighting: Maximum Allowed Retail t7isplay Lighting Wattage: For Btiil'ding Depertrnerit Use 'Location (plan #, room:#). :Retail Seles,Area TypeNOTE 1 GrossInterior Area In f?` Mowed Watts NO1 per ft Watts:Ailowec (vvettstftf x area) Serving Retail 1: AAI unclassfed retail display :140 ( 0'.60 .84 Order Retail 1: Al unclassified retail display 53, Total Retail With Display ATE ,228 I Total Watts Retail Display Ligh ing Base JI Wance Maximum: Retail ;Disp ay Allowanee0TE 3 Proposed Retail Display Lighting Wattage NorE:4 137 500 .637 Retai(Area Location (plan:#i room#) •Fixture DescriptionntlTE:6 Number of • Fixtures: Watts per Fiirfure iOtE.s Watts Proposed Retail 1 Serving Type F Surface Mouted LED 12: :4!8, Recall: Order Type D3;&D3E;Recessed LED Downlight 4 23. ;9;2 RETAIL DiSPLAY WATTAGE ALLOWANCE r AS PROPOSED Proposed Retail' Display.. Lighting Totals from LTG -INT -DISPLAY Total Retail Proposed Display WattsNOTE7 Retail Display.Power Ahowance"aTE'e 140 ]40; Retail'1 Retail !2' Retail 3- Retail4 140 Note 1 - Selectretail sales areas from drop down menu.: Only retail sales areas that complymith:0405.4.2i2.1 maybe entered in this table; Note 2-Retaildisplaylighting power-allotdences per Q495,4.2.2,1, .Equafion 4.1:1. Nofe`3 - Maximum retaildisplayutetta a alonence as calculated per C405f.4.2.2.1,:'Er/ye fion•411 . Noe4-Onlysepara�lyconVolledretail display fxtures' tatare:indee dent f generaarealight' ng per 0405. -2.2:1 maybe; entered in this table. . Notes -For proposedFixtureDescriAPion, list ALL Pl?posed.drsPle ylighting:fixtures: Indicate fixture e la.mPtYAa T-8),inumberof iasis sin ballast (ifincluded .Forlrackrli htin 'list - in. addition to. the x tU p the. bxture, ,and . Type ( .d) 9, the !en fhof the' frock: rn fee f+x. re, : 9 9 C $ . lamp,, and ballastinformation. Note 6-ForproposedWatts,Fixfure enter the lumnairew3tta5e or installed lamp and ballast usigg manufacturer or otherapproved soiir'ce. For For luminaries aiith screw-in lamps, enter the manufacturer's fisted maximum inputuattage of the fixture (not the lampuaffage), fow voltage lighting, enter the oattage of the Ira nsfurmer.:Forline voltage frackibuswey systems enter the:largeroflhe attached luninairewattage or 50eatts/linealfooiorenerthewattagelimitf permanent current limiting ui ce. Note7'-.TofatRetailProposedDrsplayNatts isauomadis llgee[eredinlotheProposed:FrxtureWafta tablein LTG -IUT_SPACE .: Nofe8-Retaildisplaylighungpoeathe:lesserofMe: Ma rm.umRetarlDrsplayAllomnce ORthe Teta! Retail Proposed d LDisTG plINay T Watts.SPAC.. Retail display wattage allowance is automatically enterecl thelVlexithum A1101(.1011 LightingWattage; labia in Note:9 - Enter a unique:title for each lobby'area in project that has artfexhibit:display lighting:: Note 10 - Lobbyarf and` exhibitdisplay we Cagealfouence per Table C405.4.2(2),.Footnote c = 0,5:W/ft. No 11 - Proposed displaylighting:totals:fa each lobbyarea per information entered info Proposed Lobby:ArtiDisplayLighling:Wattage f Li !SPLAY 20 ?/'l'" 1 " to Ener Code Com li nce Forms r Corr mercial.Buildin s indudin ',R3 'R4 over 3 stories and all p fq ._ 9 9 R2, enerat:area�}i htrn , may�ieentered rn Mrs table: Revised July 2016 Pr6$ki ll$tta4obby, finis -t,¢7( ( (At( egd gra : rVj T INT SPACE: Date 7/1/204.6 - General Note: -In Lobbyareas, an: addrtionaluattage allowance-ispermirbd'ior lighting installed specifically for the purpose of highlighting art and exhibits, Only Lobby areas WO eligible display lighting may use this additional alleaence. Proposed display lighting for each Lobby area may not exceed this allovrance.. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department artment Jse P NOTE. 9 LobbyArea o -Lobby Description including (plan # & room #); Gross Interior Area in ft? Maximum Display Watts Aflowed NOTE' Per Are10 a Proposed Display: Lighting Total, :. Per Area NOTE 11. Applicant Email:; Projeci'Descriptiort ® New Building ■ Addition ■ Alteration D Plans Included, fnclude PROJSUM form;{inchmded in`envelope;tbrms uorkbooNd 'sith :'llghfingcompllience:forms. BuildingAdditions . :Refer to Section 0502.2.6 for•addilonal 'requirements. Compliance Method I interior lighting 1 Exterior lighting Lightisystemn ddition: area Comply- with;alt applipable i as a: staind aalone:new construction•project t ■ esprovisingons f Lighting systems:in addition are combined with existing lighting systems to demonstrate compliance I• ■ 111building l Additionts,cbnbined•with existing Forinterior lightingprojects, include stew + existing' interiorlighting.fixture wattage orPrmosed ,Lighting Wattage table in L,TG-INT-BL.D orLTG-INT SPACE form. • For extelfor lighting•projects, include new +:existing• exterior fighting fixture wattage sin. Proposed Tradable and•Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. interior and Exterior Lighting Altexatians Select alfLrghttng Power ConGoF etementsthat of the-refrofitproject::af •combinatlonofspaces 50%of the existing fixtures•arereplaced in somespaces and fixtures are r •placed, :provide separate fightfngpower complianceforms1orthetua.retrofit conditions- Spaces undergoing {ype•of retrofff maybe 7ightingpoweir compfrancefcrm:, Refer to:Sectien 0503.6: requirements.: ;All alterationliglitingtailrolS:shadbe co D4:08.3.,•.. _ mmfsslonedper® and Lighting appJyfo the scope:: proJecfincludes a where less than: 50% ormore of the fn ofhers;'th• en - the same •combined into one' for additional o lighting are not Lighting Power j Interior lighting ; Parking garage i Exterior lighting 50%,oc more:of existing are replaced' { ■ ■ { I t — Lessthan 50/o:ofexistin arere laced 4 ® ■ °. 9 p - 1 ` Lampandforbatlast replacement only - existing total wattage not increased) D i '' IIi ■ g '• -to-remain fixtures shalfcomply wfh + existing -to -remain fixtures: in. • or LTG-E)CT!form. fixtures shafinot exceed -to -remain: fixtures in fhe:Proposed• LTG-EX.T:tPrm.. parking;garages, .and tete! Total ,Lobbywith Display Are Total Lobby Art/Exhibit Display AAowanceNOTE 13 Proposed: Lobby Art/Exhibit Display Lighting-Wattage."°TE'2 Lobby Area Location: (plan #, room) Fixture DescriptionMOTE' Number ,of Fixtures Watts per. FixttireNOTE,s Watts Proposed.. Total Lobby Art/Exhibit Proposed Display Watt" Interlcar 1 1htlr>~ � �Space-By-Space <IVleth®d � OF_ . rcTGmINT SPACE 2015 Washi ton State Ener9yCode Cem Iia ce Forsroi' omm rcla0t 6 u In s nclud fn9 R2;3, R4 bveri8 stoles all f. R., R e'' ust 1 ev 5 drui 20 6 9 Project Title. ::00.04i-A041o99r•.17333 .•gdp at'Or ekinry,T.Oi iiia .INA slate: 7%1,/2E?1;6 Calculation Aream°1E s,: Q .:: Add' on-:Additio � n o �. standalone +exlsting Spaces where < 50% ofSpaces where a 50% 01 lumfriaires are replaced= : Wmiflaues are replaced •' LPA Calculation Type Q Standard: • 0 Addbonal Efficiency Package Option.. Q: 0406 3cReduced nteriortight ng Power To cnmpty with 04063, iIleProposed LPD: shall be 259Ctower'fhan the Target LPA Refer.ta 0406.3 for addifianal requiremenisr: ' For Building De pPartment Use Maximum Allowed Lighting Wattage"PTE .1 Location (plan:#; room#) Space Type: Gross interior: Area in tt�2 Allowed. Watts•perft2 Waite Allowed 4wefts/ft2 x area) Dining Room' Dmjng areb.Family,d'rriin'g areae 2464' ;':p ;710' 1749: Kitchen, DnVe- Thru. Food•preparai°n 187 7` '0 -796: 1483 Restroom: Vestibule, Coredor. another 49 0.530:; 79 Manager Office Oftce: Enclosed 47'. 0:890 • 42 Restrooms Restroom:.all other: 342 0.780: '267 Serving /::Order Sates Brea 22:8 1.270.: 24D Total Area Retail Display PJlowance:fiom LTG -ENT -DISPLAY 5107 Lobb ArtlExhibit:Dis E Allowance from LTG 1NT'DISPL Y NOT8E Proposed. Lighting .wattage' 140 Allowed Watts 4.050 Location,: room • Dining, order Dining; Order Dining, Order. Kdchen, Drive- Thru l<itchen.`Drws- Thru KItchen;:Drive' i'tiru • Office UntSex RRA &B' UnISeI RR A & B Entry; RR'Vest, Fixture`: Description NOTE_4. 5�b..... Type Da & D3E RecessedLED DownligtiT: Type U Glass LED Pendant Type P1. LED Pendant; Type PC AE Recessed LED•4` LD Troffer' Number of • Fixtures.:' 56 ;10'__ 4 22: Type D3 &;D$E Recessed i.ED Dawnfight. Type F Surface iviouted LED AE Recessed LED 2x4' LED Troffer: Ty:01)3 &<D3E Recessed LED Dowrllighi[ Type NRestroom UanttyCFL--Sconce Type D3:.&'D3E,Recessed LEDDownlight 4! 4 4; 4, Wattsl F xtureNOT 23 8. 22 71:: 23 7,1. 19 23; Wafts' • Proposed 1288 75 68 1.562 92 48 '71 138 76 -92 Proposed Retail•Drsptay Llghting;from LTG -INT -DI SPLAY: T.ota1 Fro osed WatiaMay not exceed TotalAtlowed W4£tsfot:InferianLighting. 140 Tota} Pr" osed Watts 367:0: Interior Lighting Pourer Allowance COMPLIES Note _9; isf allun ue s aeef esperT2bte04054.22fhat,pcpurth`.eproect .. ,e. .Sspace•/. XPa c ote o N.per firo drop do ver. e nu• Note 2-Indcate•ceifin bel3htforalriuns:and s aLesufizin9the cells 9 ei9ht ad1tmenper'Table 0405.42(2 Footnofesdlhrtut Note3-Listaflpro osedlsh.in 4Xtures. nCludN9exerrW fi htin e9u+:mentnd:exlst•n-to-reroan:fxtures Note 4 -.For ro osed ix ure SC ti' 1, n wale f 'r .t p e: to e � T- :number Of le sin 08 t,4ture and baAas1 e t Jncfuded ; :For A p F t .De rip qn,.a d .,,.rctueYA,,: rrtoty.. .„9 ...8)...n .. tfYA (f.._._.:I_ frac l htin 1' " , and ballet. r ' ti o k isf fne'I r t.i. : d r to' i`ie-focture :fam n s info ma on.: en th.of the t tick in:tee . .ad if on t Not5'- For lighting;equipmgnt eligible foraxempUort per 0405=4.'fnote'ycfinhuberanleaveWattslFixture blank: . .epomd 'Note 5=Existin -oremainflir0iresshabeinetudedfn.eProposed ightin Watta a table•inthe santernannerasnew f„tures identstyasexist in` g i{fixture•descnptron;..: Note - or ro ose W ,: ' . r A..:d a an alt Firs rnan f c o 7 F p p d atls/A dura•enterahe.luniinaire wattage. io ins a . ! mp d b as Rg u a tuner or other. approved soufce::For.• luminaireswIlh.scre h `n a r'sfistedmaximum. ulwafte e:ofthe:fixture no'th 7 o u: w-rn lamps ;eider! e man facfurer p g . i f e. amp walfage). F c low ataga Ii' r u wa r r Mise ente fnewaffa eof e;transfonrie Forfinevo7ta e.tracWb s stems enterthela e oflhe aftasnedluminaire wattage ar .: watfs/lineal foot, or:enter the wattage ilmitof:permanent rre cunt limiting device-: •Note 8 . tobbyArt/Exhihit DispfayAllowence is Independent of the Maximum Allowed Ltghlxig Wabage; Note 9 :Galcufalion Area ctails :.a Li htin :fixtures•+iii a buildxi :addition ma � com as a stand alone ro act or th ma be combined with:the:overall extsfinn `buildini ._ 9 g 9 X AlY R ;Je ., eX Y g. 9 lighting systems fo demonstrate compliance Refer to .0,....9...i1.-.. b. For alterations and buikling:additions provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. if a building iaddition will comply as combined Will the:overall existing budding fighting systems, include all applicable existing Space Types and gross interior areas. c. if less than 50% of existing lighting fixtures will be: replaced provide total existing lighting; wattage {prior to alteration) in the space provided LI Mise suriiniary LGT=SUM 20/5 Washington Stat Ener Code.Compliance Forms for'Comnherci B ildin .indudin R R R4 over 3 stories'a d all R1 YVa gt a Energyal u gsi g ?, 3, n Revised August2016 Projecttufoprojec Comphanee forms do not ;equine a', use. instructionad calculatinl. angcelis are wife,. ,protected. Ti.tte;• Chlc.}.A 04A94- 17333:authcenta kwF,ukwllaWA Cate 7/1/2.016 ti : ,. R licaritlnfarmabon. Provrdecpntacftnformabonformdividualvho:can. pP .. - respond to inquiriesaboutcamplranceforminformaiion provided. ' iidin e a men : e For:.Bu D.p rt tUs 4 CornpariyName:: Pro ettMEP Inc.. Company Address: 1221 East Dyer:Road, Suite260 -Santa Ana; Ca 9270,5. Applicant Naive: Applicant Phone:: Applicant Email:; Projeci'Descriptiort ® New Building ■ Addition ■ Alteration D Plans Included, fnclude PROJSUM form;{inchmded in`envelope;tbrms uorkbooNd 'sith :'llghfingcompllience:forms. BuildingAdditions . :Refer to Section 0502.2.6 for•addilonal 'requirements. Compliance Method I interior lighting 1 Exterior lighting Lightisystemn ddition: area Comply- with;alt applipable i as a: staind aalone:new construction•project t ■ esprovisingons f Lighting systems:in addition are combined with existing lighting systems to demonstrate compliance I• ■ 111building l Additionts,cbnbined•with existing Forinterior lightingprojects, include stew + existing' interiorlighting.fixture wattage orPrmosed ,Lighting Wattage table in L,TG-INT-BL.D orLTG-INT SPACE form. • For extelfor lighting•projects, include new +:existing• exterior fighting fixture wattage sin. Proposed Tradable and•Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. interior and Exterior Lighting Altexatians Select alfLrghttng Power ConGoF etementsthat of the-refrofitproject::af •combinatlonofspaces 50%of the existing fixtures•arereplaced in somespaces and fixtures are r •placed, :provide separate fightfngpower complianceforms1orthetua.retrofit conditions- Spaces undergoing {ype•of retrofff maybe 7ightingpoweir compfrancefcrm:, Refer to:Sectien 0503.6: requirements.: ;All alterationliglitingtailrolS:shadbe co D4:08.3.,•.. _ mmfsslonedper® and Lighting appJyfo the scope:: proJecfincludes a where less than: 50% ormore of the fn ofhers;'th• en - the same •combined into one' for additional o lighting are not Lighting Power j Interior lighting ; Parking garage i Exterior lighting 50%,oc more:of existing are replaced' { ■ ■ { I t — Lessthan 50/o:ofexistin arere laced 4 ® ■ °. 9 p - 1 ` Lampandforbatlast replacement only - existing total wattage not increased) D i '' IIi ■ g '• -to-remain fixtures shalfcomply wfh + existing -to -remain fixtures: in. • or LTG-E)CT!form. fixtures shafinot exceed -to -remain: fixtures in fhe:Proposed• LTG-EX.T:tPrm.. parking;garages, .and tete! ::_ 50%ormore replaced', Total fighting power of never+ exrstin total LPA erSections 0405 4.2 and 0405.5.2. Include new P . Proposed LightingWa•ttagefablein4TG-1IVTBLD,LTG-INT-SPACE • Less:than 50% replaced - Total lighting potter-:ofnew+.existing-to-remain the festal lightingpower' prior to•alteration. Include new:+ -existing Lighting Wattage table inLTG-INT-BLD, LTG-INT-SPACEor 50% threshold appliesto number of luminaires for. interiorspaceSend insteltedwattage for exterior luminaires. • Ll htln Controls #• Inte for lighting g _ ..9 ..._ ri g g Parkin arae i Exterior lighting t . g 9 9 . , . err gb i 9 '" i — { New wiring installed to serve added ■' fixtures• andterfixtures.relocatedto ) D new circuit(s);. i t New'or moved fightin•g anal. ■ ■ panel. :._ __ _ _ manual confrof5 per 0405:.2.3,: controls per 0405.24ariorapphcation' ovider uired o•n s• :c. 05.._- eq c fro! • 4 2 7. g and automatic controls:thatapply .toa:newinterior not apply fo. e PP X r configured interior space is reconfi• gured - ■ luminaires'unchan ed orrelocated I. New wiring orcfrcuit - For inferiorlighting, proofde required occupancy sensor controls per 04052,1, daylightresponslve i ti_ .controls er0405. 5,exteriorlighting, specific: l h P 2, For Pf ng_ ,., _ N moved' anal -Provide alfa licableIi htf conirolsas-notedforNewWirin • ew.or P pA 9 n9 Is ,4. tr h. canlro r C 0522. meswatc _ . Reconfiuredinteriors ace-Provideallrequiredli9htin fication s ecificfi htin - Ionto! rovisions r•04052.5:do space.:.App A 9 9 A Pe ■ Na:changesarebemgmade. .ibelinterfor afrexterfor systems: and exrstrng;space uses and nfguration c chars ed. C s c 'Use ban a Of S a e g p do ;.r er .. i ing ge . stm intenorai Mise s ems m areasunder- om a change: r s ace use are u de -fo. Ext 9.:. , 9 ,9 � .,., _ :.:. 9 .. 9. 9 n RPgra. d.: As the aPies 0405.4 21or c T with LP for n w s ace es per Ta • denbif. inte iors acesr uirin LPD u adeto the -current Codean•Pro osedLr htin ;Watta f fy r A ?q 9 A9r R 9 9 9e table.in LTG -INT. --BLD or LTG-INT-SPACEforirt. Lighting Summa 9 9 con LPTTTTS U Iii 1 Washington State Ener Code Co 20 5 Wa net n Energy motion ce Forms tor;Cotnmeretal Buldings'lncluding R2, R3, R4 over 3 stories andall R1 Revised,August 2016 Project Title:. Chick -til -A'04094' =17333 Southcenter Pkwy, Tukwila, WA Date. 7/1/2016 Interior Lighting System Description` Interior lighting fixtures are LED source with a few fixturs being compact fluorescent er: control' p Source. AI[ interior rlighting circuitsare controlled by a;lighitng'contactopanel which can be bypassed for emergency and egress ligating requirements. Contactor panel is fully programmable with astronimical timeclock and roof mounted photocell. Interior; Lighting Power AllowanceMethcid D Building Area -Med -pd ja;Space-by space.fvletf od Sated method used in project. Interior Lighting Controls :All 0405.2.1="C405.2.8 Conircils Additional Efficiency Package Option ,._ 04064 Enhanced digitallighti.ng:controls D0405.2 Exception SLuminaire Level Lighting Control ,(LLLC) To complywith0,4064 no:fess.than, 80% df the totalinstalled interior:lightingpower shallcampl} with required confrolsper.C406.4. Dwelling Unit Interior: Lighting Perrnanently insfalled irrterio(fighting'tlxtures in, dwelling units comply'with 004,05.2 thru C'405 5 Commercial Lighting Conlrots and`LI°A.. 004,06 3 High Efficacy Lialting Q 0 Exterior Lighting System. Description Exterior lighting fixtures are LED source and controlled by a' programmable lighting contactor control panel with astronicimal timeclock and roof mounted photocell. RECEIVET) CITY OF TOKWILA NUV 21 2017 PERMIT CENTER D C B A Kt& Chick fil A Buffington 52 00 Road d Atlanta, Georgia 2998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 u_ S.. COi el) gl L a a L � 8 70c.,Nem 0 u) m o m ~ r FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEC 13 2017 City of Tukwila BUILDING DIVISION (/) ARCHITECT'S PROJECT # ##### e48 cn 0 ■e=i 0 SHEET a. ENERGY FORMS PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET NUMBER E-903 11/9/2017 5:13:05 PM 4 Lighting 9 5Motor andElectrical Permit Checklist Pg �4 .�.� 2015 Washington Stain :Energy Code Compliance Forms forCom:nierciar Buildings including R2, R3,•R4-over 3 stories;arid.all R1 o M t r and Elect is r al PeriTiit�Checklist �P 2 fonbtata Ene y Code Com Banca Ferms forCommercial Buiidinge ii udin' `.- �,ever 9„ r9Y. .P 9 g.R2,.R3, ft4 3stones and �LTG-CHK Revised August. 2016 Prolett Title.. Ch_ick-filA04094 47333SouthcenterPkwy,Tukwila,WA Date 7/1/2016, The following: information.is necessary to check'a permit a.- lication for coin lianne q with the lighting, , motor, and: electrical requirements in'ther, ..: . -. Washington State Energy Code, Commercial Provisions. Applicability .(yes,no,na) . Code Section , . ;Component: Compliance information required in permit documents , . , , , Location in Documents , Build€ng.Department„ Notes MOTORS & TRANSFORMERS NA 0405.8 Electrical t2nfaniiei• Include electrical transformer schedule. on : electrical plans - l indicate :'transfomiersize, efficiency, or exception taen N/A Yes NA 0405,7 Dwelling unit electdcalenergy: consumption Indicate!on electricalplans that each dwellingunit in GroupR-2 e has aseparate,electrical energy meter NIA. irA Yes 0405.8 Electric motor efficiency Include all motors,: including fractional tip rrlotars,inelectric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied E-2,3 NA Yes C405,9.1 Elevator Forluminaires in each elevator cab, provide calculated average efficacyofcombinedfixturesthat indicates:: efficacy` is.nottess than 35 lumensperwatt Indicate; rated watts per cfm for. elevator cab ventilation fans do not exceed 0.33 watts per cim_ indicate automatic controls that:tie-energize lighting and ventilation fans when elevator is stoppediand unoccupied for a period of ib minutes or more. . NIA. NIA: Eyes NIA Means Of egress'. lighting tcA:. 0405,9.2. Escalators and. moving walks Indicate escalators comply with ASME Al7.1ICSA B44; automatic controls are configured to reduce operational speed. to the minimum permitted when not in use '.NIA. Exterior lighting controls NA C405.9.3 Regenerative drive Indicate all one-way: down or reversible escalators are provided; . with a Variable frequency regenerative drive NIA E-1;1 ES -1 E-2.3 i•...1.1 E , Yes 040510race Controlled reties P' Ident(fy;all controlledand uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled,;du,plex devices, etc; For building grounds•fixtures greater than 100 watts •, indicate, on plans whether fixtures have efficacy greater than BO lumens or; are controlled by motion sensor, or are exempt lighting per 0405.5.2 ES1, E1'-1, & E-3:1 • : Indicate on plans whetharthe method of automatic control for each controlled receptable zone Is by occupantsensor or programmable time -of -day central E-2.5, E-3.1 0405:2,5: ..._ .. If "no" is selected for any question, provjde explanation;' End of Lighting, Motor & Transformer Permit Documents Checklist Lighting 2015 Washin o M t r and Elect is r al PeriTiit�Checklist �P 2 fonbtata Ene y Code Com Banca Ferms forCommercial Buiidinge ii udin' `.- �,ever 9„ r9Y. .P 9 g.R2,.R3, ft4 3stones and LTG -CHK ..g. Revised 2016 Project Title:: Chiek4il-A 04094.17333 Southcenter Pkw ,•Tukwila,rWA Date 7/1/?(46 Thefollowing.' information.; isnecessary to checkapermit application for compliancewith the lighting, motor, and electrical requirements in:the Washington State Energy:Code,:Corn tenial Frov€sighs. Applicability• (yes,no,na) Code Section Component. CbmplanceInfarmation required in permit documents Location; in Documents. Building Department; Notes #A. "torrid 04052:5:- Item:3.. Hdel/motel g'ue'st: rooms Indicate method of automatic control - vacancy or captive key: ail! installed uMina€res:and svvatched:receptacle.s..in: guest room NA. 0405.4:1 0405.4;:1 C405,42 - . Yes 04052 5 -. Item`4 Supplemental task lighting • Indicate method and location of automatic ;shut-off vacancy control for supplemental task lighting, including under-shelf;or under -cabinet lighting E-1,1 & E-2.4. Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently irA 0405 2:5;-=, ftem.5 Lighting.fornon- visual • applications Indicate on plans•eligible non -visual lighting applications, include: sq. ft. area of each lighting control zone; Indicate on plans that non -visual' lighting are controlled independently from both general' area lighting and other lighting applications within the same space Indicate method of manual lighting control. and•applicable automatic; lighting control WA. N/A:. WA Exit signs NA - 0405.2.5 - Item& Lighting.equipment for sale or demonstration Indicate on plans that' lighting equipment for'sale or demonstration are controlled independently•from both general. area lighting and other lighting applications within the Carrie • space Indicate method ofMantri‘inig-hirni.e.ontrol and applicable automatic lighting control• NIA NiA C405.1 Eyes 04053:5= Item.7 Means Of egress'. lighting Identifyon plans egress fixtures, that function as boot normal .. . - and emergency means of egresSillumination; • Provide calculatoh: oflighting power_density of total:egress lighting _.__. ____,. Iftotalegress lighting'power density is greater than 0.02 Wlsq..' it., indicates: on plans:egressfizturesrequiring automatic shut-off during unoccupied periods Indicate; method of automatic shut off control E-1.1 &.E=2:1 • E-3.1 E-1.1, 8-2.1 E-1.1, E 1.4 SA Yes 04052.7. Exterior lighting controls Indicate on extenorlighting plans and fixtureschedulesthe automatic lighting control method, control sequence, and. locations served;. fa ade and landscape lighting, Indicate automatic Forbuitd€n9 4 controls shutofflighting•as a function ofdawn/duskand fixed• opening/closing time; ES -1, E-1.1 &.E-3.1 .,,,.v_._....,-.._,_-�,,,-,.- ES=1, E-ta; E .3: & E-3.1 , For all other exieriorlighting, indicate automatic controls shut cft lighting as:a furict ion of available daylight;include control sequence.that also- reduces lightingpowerby at least 30% between 12am-6am,orfrom 1 hour after closing to 1 hour before opening, or based uponmotion sensor E-1;1 ES -1 E-2.3 i•...1.1 E , NA Yes C405.5.1' Exterior balding grounds lighting controls For building grounds•fixtures greater than 100 watts •, indicate, on plans whether fixtures have efficacy greater than BO lumens or; are controlled by motion sensor, or are exempt lighting per 0405.5.2 ES1, E1'-1, & E-3:1 • : 'Yes 0405:2,5: ..._ .. Area controls - Master control swdCheS and circuit power limit indicate location(s) of master, control switch(es) intended to control multiple independent switches;circuit breaker may not be used as a master central switch ._.:_..._.__ ,_. _�._ Verity thatno 20 amp: circuit controlled by a single switch or automatic control is loaded beyond 80% 8-2.1 ..,_ _ - 8-3.1 NA Enhanced digital: lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming or exception taken; Include calculation of percent. total installed Interior lighting powerthat is configured with required enhanced lighting control functions (min 90% tocomply with additional efficiency package option). NIA WA • NA 04052,2.1' 0405.2.2.2 C40523occupancysensors C405:13 04083 Lighting system. functional testing If claiming lighting system commissioning_exemptionprovide supporting; calculation; Identifyapplicable commissioning documentation requirements per Section C.408 or eligibility forexception;, Provide written procedures for functional testing of all automatic controls: and describethe expected system: response N/A N/A WA Total connected exterior lighting power.___ Li htin ,, Motor and ElectricalaPermit - . _ 2015Washington:State Energy Cada Compliance Forms Checklist P 3 -- L TG -CHK for Commercial Buildingsindudmg R2,R3 ,R4over3 stones: and. all: R4 Revised Augusi(2016 Project Title: Chickfit-A 04094-17333 Southcenter Pkwy, Tukwila, WA Date 7/1/2016 The- following information: is necessary to check a:pernit application for compliance'with then tin motor,'.and electrical requirements the • 9h 9. 9 Washington State Energy Cade,.Conimercial Prbvisibns.. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY (yes`,no,na) Yes 0405.4:1 0405.4;:1 C405,42 - . Total connected rntenor lighiing power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Ident s aces eli €ble for Ir htin fly p g g g,pawerezemphon on plans and in compliance forms; indicate the exception applied Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; E-1:1 NIA ........ N/A• LIGHTING CONTROLS ". _ , Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Nva Forall lighting fudures, indicate lighting control' method on plans for spaces and fightinglzone(s) served, or exception taken E-1.1, 8-2.1 & E- 3;1 Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per re in lighting fixture schedule (maximum 5 watts per fixture) E-1:1, E-2.1*ti BA C405.1 Lighting in dwelling units -tamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units,: indicate; in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1_ Calculate percentage of fixtures: with high efficacy lamps in project (min 75%to complyw€th exception). NIA:, NA SA 0406.3 Reduced righting power density- dweiGng• unitlamp efficacy For project•, with dwelling units, to comply with; additional efficiency package' option indicate in lighting fixture schedule iif • lamps infodureshave 'efficacy rating of60lumens per watt or more. Calculate percentage of fixtures with: lamps that have this efficacy ratin g (min .95% to comply with option). WA 0405.2'3 Lighting Power Calculations Indicate compliance path taken. NA C405.4.2.1 Building Area Method: Complete required compliance. forms - proposed wattage per building area does not exceed maximum allowed wattage per balding area. Identify locations of building areas on plans NiA,, E-21 .iYes 0405.4.2.2E=5r1 Space -By -Space Method Complete -required compliance forms - total proposed wattage dries not:; exceed maximum allowed wattage.; Identify locations o' space types on plans, including retail display areas, lobby art & exhibit display areas; and ceiling heights as, applicable NA 0406.3 Reduced lighting • u powerdensity To comply with additional efficiency package option, deem strate inopompliance forms that total connected interior lightingiwatts a is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method • NIA. -Yes 04052,2.1' 0405.2.2.2 C40523occupancysensors EXTERIOR LIGHTING POWER 8.. EFFICACY indicate on.plansWhich'method ofManual 50%lighting load reduction isprovided, orwhetherlighting load is reduced or daylight responsive controls Yes 0405.5;2 Total connected exterior lighting power.___ Include all luminaires in lighting fixture schedule; indicate fixture types lamps ballasts; and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption ori plans: and in compliance forms; indicate exceptior applied __-_______ r_ W..__ ------------ --�' Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting, include exception blainied for each fixture or group:of fixtures under exception category E-1.1 NIA _ NIA. Indicate:on: plans.the method of automatic shut-off control dungunoceupied periods(occupancy sensoror time switch) E -14,'E -i.4 Yes Table .. „) 0405.53(1) Exterior lighting zone Indicate building exterior lighting zone. as defined bytheAHJ . E-5.1 Yes 0405.5:1that Exterior building grounds lighting for building' grounds fixtures rated at greater! than 100 watts are complying based on efficacy, indicate: rated lamp E-1.1 • efficacy (in lumens per watt) in fixture.schedute Indicate on plans the sp aces:served by'occu ancy sensors; :Yes 0405.5.2 Exterior lighting . power calculations Complete required compliance form proposed wattapefor exterior lighting plus base site allowed does exceed . maximum allowed 6Sb1 Indicate whether occupancy sensor controls are configured to Exterior .-Lighting Li a=EXT 20 t S,Washington State Energy Code Corripli once F. grins for C of mercial:Buildings including R2, R3 R4 overa:stories andaA<Ri Revised August 2016 Project Title:: Chick -til -A 04094.17'333 Southcenter Pkw y, Tukwlta, WA; Date_: 7/1/2016 Exterior Li tin' Zone Table 0405,i.2(l Specified by jcirisdiclio n... O Zon:e;1 O Zone 2 O Zone3 Q Zorte'4' . Zone: se/ection required to enable LTG.=E)l'T form. Calculation Area O Alteration with <' 50% ext: wattage replaced. ddition Q Addition O A: • stand One. + existing Alterationwith.Z 50% ext. wattage: replaced... FOP I3u€Iden, fig: Department Use, Building Grounds AAAlies'to luTina ires> 100 Waifs Effidacyi> 80 lurriensiwatt 0 Controlled by motion sensor Q''Examption Tradable Maximum Allowed LightintgWattage "a E' Base Slte Allowance: Trade ble:Surfeces_ SuriaceDescription' Areaiff jt):;:perimeter (If) or # Of items Allowed Watts per ft2'orper If .1300 Allowed.:Watts- Uncovered Parlang and drives Asphalt Parlang.Area and Drtyeways 53732 • 0.1O.'Wf t2- 6373 Grounds Walkways <14wide Trash Enclosure Dump$ter Area 340_ 1.0 . :.W JaE 34,0 Total Allowed•Tradable +'Site Allpwanpe Watts:, Tradable Proposed Lighting Wattage"OTE2 8014,..,, Tradable Surface Fixture Description 19TE3;4. l: Numberof Fixtures:: Watts:per. Fixture NOTE,5, Watts .Proposed_ Un covered Parking and drives:, Type OA 7 138: 96.6 Uncovered Parking and drives Type OB .9: 236 '24 8:4 Uncovered.: Parking end drives TypeOG .50. 100 Grounds Walkway <10wide Type::i 1 91. 41, Grouhds Walkways <10 wide Type CR 1:. 26 Tote! proposed tradable waitsmayhot exceed'1he sum;of.totat allowed tradable; wattsplus-the:base•siie'allawancet Any base site allowance not needed to make tradable wattscomply•can be applied (o individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage"" '°'1 Total ProposedTradable Watts;: 26i' 3517 SiteAllowanee.Remaining :1300: Nan -Tradable Surfaces Surface Description, Area(ft2}, perimeter.' (Ir) or # of items Allowed Watts per 112 or. per If Allowed Wafts x ft2 (or:x If): Bldg:: Facade Exterior. Building Wails and Canopies 7912. 0.2 W/ft2 1583 Dive up Windows &Doors Drive Thru Window With II lu rninated Canopy 1 :40 OW/driveup 40;0 Non -Tradable proposed Lighting Wattage"CTE Non -Tradable Surface ....,._ Fixture DescriptionNOTE 3,4 Number of Fixtures Watts. per Fixture NOTE5 Watts Proposed:' Drive. up Windows & Doors LED 4 10. 38 Bldg, Facade Type OE 14 . 24 336 (yes`,no,na) Code Section Component. Compliance information required in permit documents Documents Non -tradable proposed walls may exceed:allowed wafts for any individual surface unless the tota)'excess watts. for aling n-traclabie surfaces:ere less than the remaining site'allowance;° Non -Tradable Watts. Exceeding LPA: 0' .Remaining Site Allowance_ 130'0 Exterior Lighting COMPLIES WITH MAX. ALLOWANCE' Note'fl -List. all unique exterior sufeces per'Tab. le 0405;5 2(2) I/r !'occur is'.ffie projectscope, Select exterior: surface categories:from drop down, menu..: A P lures Incfudtng existing -to -remain fixtures:. Cie 2 Lis t a!i proposed:Jighting fiX Nofe'3 For pro aced Fixture-Descriplian indicate•fixfure.fype, lamp type, noir tier offary ps in the:fxture and ballast type. (rf applicable)• Note.4 Existing fo-remain fixture-s.;shall be included In lite Tradable..andNon-Tradable Proposed lighting Wattage tables in floe sante manner as new fixtures. !dent lyes existing in fxture descrtptlon. Notel5 ForprpposedWafts'Frxture enferthe iumrnaire waifage for:.installed lamp and ballast using manufacturer or other approved source::For lumina res wifhscrew-in lamps, enter the manufacturers;listedmaximum inpuf`w.attage,of the fixture'(riot lite lamp watfage), Far low voltage: lighting, enfar the wattage of the transformer, r -°amu: -Lihti.._:-2 Motora nd El ectricalPermitC-..h. etli t Pg tH..�-„ 2015.WashmgtonState Energy Cade Compliance Forms: forcommercial' Coldings inciudng R2,: R3, P4 -over 3is 055 and all Ri RevisedAugust:201- Project Title: Chick-fit-A,04094-:17333Southcenter•Pkwy; Tukwila, WA [Date 7/1/2016 The following infomtation is necessary to check a permit application for compliance With the lighting, motor, and electrical requirements' in the Washington State EnergyCode, Commercial. Provisions. Applicability • Location. in Building Department (yes`,no,na) Code Section Component. Compliance information required in permit documents Documents Notes LIGHTING CONTROLS Yes 04o5.2 Lighting controls, general' Forall lighting fudures, indicate lighting control' method on plans for spaces and fightinglzone(s) served, or exception taken E-1.1, 8-2.1 & E- 3;1 Luminaire level Indicate onp lain all fixtures provided with LLLC in lieu,of Yes C4052. lighting controls (LLLC) 0405 2 lighting controls; provide description of control capabilities and performance parameters E-2.1 NA 0405:1 Lighting in dwelling units For permanently installed lighting fiXtures in dwelling: units, indicate lighting control method on plans for: spaces and • lighting zone(s) served, or demonstrate compliance with high efficacy exception' WA 0405.2'3 Indicate, on plans the m.method et manual lighting-central(whethe Yes 04052.1 1 04052.2;2 Manual controls combined with occupancy sensor, automatic light reduction, -- • E-21 04052,4 daylight responsive or; specific application controls) •, location of 0405.2 5 manual control device.andarea or specifice application it serves -Yes 04052,2.1' 0405.2.2.2 C40523occupancysensors Mana[ ncon r€or light€ng controls indicate on.plansWhich'method ofManual 50%lighting load reduction isprovided, orwhetherlighting load is reduced or daylight responsive controls s. -2.i Indicate:on: plans.the method of automatic shut-off control dungunoceupied periods(occupancy sensoror time switch) E -14,'E -i.4 Yes 04052:2 Method of automatic shut-off control for all lighting zones;. Indicate:locat€ons where ai tomaticahutoff is provided by other methods (occupancy•sensor or digital timer switch) orwhich time switch•control exception applies 8=2.1 Indicate on plans the sp aces:served by'occu ancy sensors; 6-2:1 Yes 0405.2,1 Occupancy sensor Indicate whether occupancy sensor controls are configured to C40.52 1.1 controls be manual -on, automatic 50% -on, or serve a;space eligible for automatic100%-onper exception 8-2.1 Occupancy; sensor Indicate aisleways and, open areas, in warehouse spaces_ siA C405.2.1:2 controls - warehouses provided with occupancy sensor controls that reduce lighting powerby`50% - N/A CA 04052,6 Digital limerswitcn Indicate required digital. timer switch control function Wien control fs;use• tl NIA;. ryes 6405,2.2.1 Automatic time switch controls I10100locations of override switches on plans and the lighting zone(s) served, include area sq. ft 8-1.1; E-2,1 &E - 3.1 04052.4.2 Daylghtzones Indicate.primary and secondary sidelight daylight zone.areas on plans,. include sq:.ft. Indicatetophghtdayllghrea fzoneasonplansindudeft sq', Er21 NIA Yes 04052 4.3 Sidelight and topl€ght • For small Vertical fenestration assemblies (rough. opening'less than 10 percent of primarydaylightzone) where daylight responsive controls are not required, provide:fenestration :area to daylight zone calculation(s) WA• Indicate on ,'plans lighting zone(s) served by daylight responsive controls, E-1:1, E-2.1 &;E=' ..... Identty sidelight and toptight daylight zones that are not . provided with:' daylight.sensingoontrols and the exceptions) N/A Yes 0405.2.4 Daylight responsive controls that appy ••• Indicate on plans the lighting load reduction method continuousdintmng or: stepped dimming that provides at east two even steps between 0%-100% of rated power; , Indicate that:daylight sensing controls are configured to completely: shut offaltfcontrolled lights'in the lighting zone, ......,:.. E42.1 E-1 I, E-2.1 & E- 3.1 ...:...... ::.»..:...:::: NA 0405.2.5 Additional controls s - Specific application I€ghting..controls. Identify spaces and lighting fixtures `on plans that require specific. application lighting controls; per this; section N(A. Indicate on plans that display and accent lighting, and display ease lighting are Controlled independently fromiboth general E-t.1„g-2.1 &'E-• `Yes 04052.5.-. Displayan'daccent area lighting and otherlighting applications. within the:;same 3.1' ' ' Items 1 &2 lighting space Indicate manual and automatic lighting control method E-1:1,, E 2.18 E-• 3.1: RECEIVED CITY OF TUKWILA: MSV 21 2017 PERMIT CENiTER D C wvse:A0 Chick fir A ■ 5200Buffington ffin u ton Roa d g Atlanta, Georgia 4 g a 303- 9 2 998 CONSULTING ENGINEERS Project MEP, Inc. 1221 E. Dyer Rd. Suite 200 Santa Ana, CA 92705-5636 (949) 428-8800 A 4 3 2 17333 Southcenter Parkway Tukwila. WA 98188 FSR# 04094 REVISION SCHEDULE NO. DATE DESCRIPTION REVIEWED FOR COMPLIANCE WITH NFPA 70 a NEC DEC 13 2017 City of Tukwila BUILDING DIVISION ARCHITECTS PROJECT # tit Mit PRINTED FOR Project Status DATE Issue Date DRAWN BY Designer Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. SHEET ENERGY FORMS SHEET NUMBER E-904