HomeMy WebLinkAboutPermit EL17-0997 - FLOOR & DECOR - PANEL AND TRANSFORMER, LIGHTINGFLOOR & DECOR 17651 SOUTHCENTER PKWY ELI 7-0997 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3523049088 Permit Number: EL17-0997 17651 SOUTHCENTER PKWY Project Name: FLOOR & DECOR Issue Date: 3/5/2018 Permit Expires On: 9/1/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LEVITZ TUKWILA LLC 180 N STETSON AVE #324-D , CHICAGO, WA, 80601 VLAD USACH 2518 22ND AVE CT NW , GIG HARBOR, WA, 98335 SOUND VIEW ELECTRIC LLC 2518 22ND AVE CT NW , GIG HARBOR, WA, 98335 SOUNDVE913KQ Phone: (253) 225-4433 Phone: (253) 853-3003 Expiration Date: 5/20/2019 DESCRIPTION OF WORK: INSTALLING (2) 480V PANEL (2) STEP DOWN TRANSFORMER, COMPLETE NEW LIGHTING, POWER Valuation of single family: $0.00 Valuation of mf/comm: $194,000.00 Type of Work: NEW Fees Collected: $3,761.90 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe I agree to the conditions attached to this permit. Signature: Print Name: (%0C' h Date:3—3— --c?-6/1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKYIA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. etAl-- Project No. Date Application Accepted: I %\ Date Application Expires: W \ % (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 17b L7 I S vt >kf atlly Suite Number: Floor: New Tenant: [ ;I.... Yes ❑.. No Tenant Name: t-1 a evg_ PROPERTY OWNER Name:V VA 1),9a al Vi4, Address: n / g n fe erpiii Name: City: �; `/�n0l / Stt(atte:t �, l fr ZipOl (t / 77 IV�►r J Y Vv _ l Address: M.Wax: ''MM �� City: State: Zip: CONTACT PERSON — person receiving all project communication Name:V VA 1),9a al Vi4, Address: n / g n fe erpiii Address: /I1 I f6 I i.j\tai "l 1`l vV City: �; `/�n0l / Stt(atte:t �, l fr ZipOl (t / 77 IV�►r J Y Vv _ l Phone: M.Wax: ''MM �� Email: ELECTRICAL CONTRACTOR INFORMATION Company Name: 4(2 �-v)t Address: n / g n fe erpiii ra City: G�!l—SSttateam`t ZiR,623 3� Phone:Lc9y 3>d9.5 3ax: ( s3)5l ' e2(.. Contr Reg No.S0' �fri f v c'3 jeci f Date: Tukwila Business License No;; Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): -teo Jay tyv v.. 22k1441iv1,9 (4), v -pc (2) .s-7/et Will service be altered? Yes ❑ No Type of Use: //) ofrrxe 1200A -di Type of work: Adding more than 50 amps? 0 Yes ❑ No New ❑ Addition ❑ Service Change k Remodel ❑ Tenant Improvement 0 Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication 0 Temporary Service Property Served by: fig Puget Sound Energy ❑ Seattle City Light W:\l'ermmit`Center\Applications-HandoutsWermit Applications\Word\Electrical Permit Application Revised 1-1-2017.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ I : XAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF ► E ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ij_ 'TRICAL CO ' ' ACTOR: Signature: Date: /G2//3//7 V Print Name: A D (jo C4I. Day Telephone: (23)c%9S 9 3 Mailing Address: cQS / tq Ora )9 44 or iv ki & kacr) 1 WR 9g 3 3 City W:\Permit Ccntcr\Applications-Handouts\Pennit Applications \ Word \Electrical Permit Application Rcviscd 1-1-2017.docx Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT 1 QUANTITY PermitTRAK PAID $3,038.46 EL17-0997 Address: 17651 SOUTHCENTER PKWY Apn: 3523049088 $3,038 46 ELECTRICAL $2,893.77 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,893.77 TECHNOLOGY FEE $144.69 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R13920 0.00 $144.69 $3,038.46 Date Paid: Monday, March 05, 2018 Paid By: SOUND VIEW ELECTRIC LLC Pay Method: CHECK 5852 Printed: Monday, March 05, 2018 10:12 AM 1 of 1 CRWYSTEMS 0 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $723.44 EL17-0997 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 $723.44 ELECTRICAL $723.44 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12991 R000.345.832.00.00 0.00 $723.44 $723.44 Date Paid: Friday, December 08, 2017 Paid By: SOUND VIEW ELECTRIC Pay Method: CHECK 5791 Printed: Friday, December 08, 2017 4:10 PM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit RMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3.7 Permit Inspection Request Line (206) 438-9350 Project: 0 1) Ok Type of Inspection: \ Address:/ 7 5' S,(1--- pi, - Date Called: Special Instructions: Date Wanted: 00 p• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Kkes,64, rpe inspector: Date: 06/24/6? r6? REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: r Type of Inspection: r� Address:. ,_ 7(0 1 -c- el Date Called: Instructions: • Date Wanted: i..Special i q p.m. Requester: Phone No: 2-2-C(0-13,3 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: - pal) 6) kit) Pi.)J9 Inspector: L l Date: 046 Itg REINSPECTION PEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 6, Address: (� 17c 1SC"`�1 Date Called: Special Instructions: Date Wanted6/1) f�� a:ml Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,5.1-beiyarA-r-F Inspector: ......r (7.L.16„, Date: o golbg REINSPECTION' FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit A Wk FL /7-117 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje l r°r -I-Dec r Type off Inspection: 1...e)v.cIn I,,, Etc Address: I 6 b' 1 cr2Pk4 Date Called: Special Instructions: P}r3 4 Date Wanted: a.m. p.m. Requester: o 'x G- Phone No: o G`t (i'► pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: q r .ti- __ r rovirt- Ev-rt-ij toq(( o 'x G- Ce.2 (l /- o G`t (i'► Inspect Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: IRe (S -C Special Instructions: Date Called: Date Wanted: Requester: Phone No: 2/s,-3 1(133 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: -r� epiei Inspector: Date: 011/6 (' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project:Type 6,0OA\ d''1 of Inspection: L/l�i .c Address: /�'%%6, r- i 5L--. Date Called: Special Instructions: ��/" "�y��/ "P" a/ --INE Date Wanted: �� gl..m Requester: Phone No: ;5,3 A5-- vy(33 Approved per applicable codes. Corrections required prior to approval. ✓ �Jl c ��. s- Z r FAJper appl COMMENTS: /6'1 Pk6 inspector: Date: ^374 REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: '©d d' Type of Inspection: �';�at/4 1 ` �. 1 t' iVf / Address: /76C( 76C( - Cry P7 . Date Called: ` Special Instructions: Date Wanted: ,�, % .m: Requester: V�� Phone No)c3 G��" J Lft 33 Approved per applicable codes. Corrections required prior to approval. COMMENTS: oFFccxz QeccALA-c, e Inspector: Jf,7 Date: 0 3/n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL17-0997 DATE: 12/12/17 PROJECT NAME: FLOOR & DECOR SITE ADDRESS: 17601 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Aux, Building Division it Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 12/12/17 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWERoS INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 01/09/18 ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERcS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 Sound View Electric LLC 4/111114 Washington State DeparUiient of Labor & industries Home Espanol Contact Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z .Index Workplace Rights Sound View Electric LLC Owner or tradesperson Principals Usach, Vladimir, PARTNER/MEMBER Doing business as Sound View Electric LLC WA UBI No. 602 924 353 2518 22nd Ave Ct NW GIG HARBOR, WA 98335 253-853-3003 PIERCE County Business type Limited Liability Company Governing persons VLADIMIR H USACH OLGA USACH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SOUNDVE913KQ Effective — expiration 05/18/2009— 05/20/2019 Designated administrator USACH, VLADIMIR License type Electrical Administrator Bond TRAVELERS CAS & SURETY CO Active. Meets current requirements. License no. USACHV*955KQ $4,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602924353&LIC=SOUNDVE913KQ&SAW= 3/5/2018 Sound View Electric LLC Bond account no. 105240364 Received by'L&I Effective date 05/18/2009 05/18/2009 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EHICQ00251 Issue date 12/04/2015 Violation city GIG HARBOR Type of violation ELECTRICAL CITATION Description Employing electricians and electrical trainees for the purposes of chapter 19.28 RCW in an improper ratio. Satisfied RCW/WAC 19.28.161 RCW Violation amount $250.00 Page 2 of 3 Workerscomp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account !D 185,513-00 Account is current. Doing business as SOUND VIEW ELECTRIC LLC Estimated workers reported Quarter 4 of Year 2017 "1 to 3 Workers" L&I account contact T3 / DAVID PRYOR (360)902-4804 - Email: PRYD235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602924353&LIC=SOUNDVE913KQ&SAW= 3/5/2018 ELECTRIC WALL, HEATER SCHEDULE (FURNISHED BY G.C.) MARK BTU/HR WATTS VOLTAGE PHASE AMPS MANUFACTURER CATALOG NUMBER REMARKS EWH-I 6,825 2.0 208 I 9.6 QMARK HEATER: AWH4408 MTG. FRAME: RECESSED PROVIDE WITH INTEGRAL THERMOSTAT AND INTEGRAL DISCONNECT SWITCH ELECTRICAL SYMBOL LEGEND (SOME MAY NOT BE USED) SYMBOL DESCRIPTION SYMBOL DESCRIPTION -ef WALL MOUNTED SINGLE RECEPTACLE, NEMA 5-20R WEATHERPROOF MODIFIER PANELBOARD, UTILITY POWER ABOVE FINISHED GRADE 0 WALL MOUNTED DUPLEX RECEPTACLE V 2 POOWER WER DISTRIBUTION PANEL OR SWITCHBOARD, UTILITY NIC WALL MOUNTED DEDICATED DUPLEX RECEPTACLE ral METER AND SOCKET H WALL MOUNTED DUPLEX RECEPTACLE, ONE RECEPTACLE SWITCHED OR SPLIT -WIRED -Q WALL MOUNTED JUNCTION/OUTLET BOX 4PST WALL MOUNTED QUADRUPLEX RECEPTACLE Q FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX N.F. WALL MOUNTED DEDICATED QUADRUPLEX RECEPTACLE Q C CEILING MOUNTED JUNCTION/OUTLETBOX IG WALL MOUNTED QUADRUPLEX RECEPTACLE, SPLIT -WIRED Q JUNCTION BOX MOUNTED ABOVE CEILING -® WALL MOUNTED SPECIAL RECEPTACLE,NEMACONFIGURATIONASNOTED '. "i MULTI -OUTLET ASSEMBLY ST SHUNT TRIP MODIFIER WALL MOUNTED RANGE RECEPTACLE, NEMA 14.50R UNLESS INDICATED OTHERWISE f CORD AND PLUG Q FLUSH FLOOR MOUNTED SINGLE RECEPTACLE, NEMA 5-20R/CY GROUND MOTOR NI FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE XX/X XXA FUSES SAFETY SWITCH, SIZE AS INDICATED ON PLAN ►, FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE ill FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE, SPLIT -WIRED 101 XXA FUSES CASQMBjINATIONMOGP�NCMOTOR STARTER AND DISCONNECT SWITCH, SIZE P.1 u FLUSH FLOOR MOUNTEDQUADRUPLEXRECEPTACLE _ r�; FLUSH FLOOR MOUNTED DEDICATED QUADRUPLEX RECEPTACLE $MOD SWITCH.SPSTUNLESSINDICATEDWITHMODIFIER.HORSEPOWERRATED WHEN USED FOR MOTOR CONTROL OR DISCONNECTING MEANS. SWITCH MODIFIERS, INCLUDING COMBINATIONS THEREOF: III ii FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE, SPLIT -WIRED 2: UFS•I'. 3: 3 -WAY (SPDT). 4: 4 -WAY. D: DIMMER F: BOX COVER UNIT, BUSSMANN SSU OR STY SERIES. 0: GLOW HANDLE (HANDLE GLOWS WHEN SWITCH IS OFF). H:HORIZONTALLY MOUNTED. IC: R : OROPERATED. MOTOR CONTROLLER WITH OVERLOAD HEATER. SB: SWITCH BANK (GANGED SWITCHES) OSI. OCCUPANCY SENSOR OS2: DUAL RELAY OCCUPANCY SENSOR.C/DC P: PILOT LIGHT (PIAT ON WHEN SWITCH IS ON). L. TIMER E LV: OR OVERRIDE. OT: OVERRIDE WITH TIMER WP: WEATHERPROOF DTC: SPDT CENTER OFF MAINTAINED CONTACT. DTM: SPDT CENTER OFF, MOMENTARY CONTACT. LOWERCASE LETTER: CONTROL LUMINAIRE WITH SAME LETTER ® FLUSH FLOOR MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED ®ABOVE FLOOR SERVICE FITTING, HUBBELL #SC3098A OR EQUAL; NEMA CONFIGURATION AS NOTED Q C/DC CEILING MOUNTED SINGLE RECEPTACLE, NEMA 5-20R (C=FLUSHCEILING, DC=DROPCORD) EN C/DC CEILING MOUNTED DUPLEX RECEPTACLE (CFLUSHCFILING,DC=DROPCORD) 131 CEILING MOUNTED DEDICATED DUPLEX RECEPTACLE (FLUSH CEI ING, DC DROPCORD) LI] C/DC CEILING MOUNTED DUPLEX RECEPTACLE, SPLIT -WIRED (C=FLUSHCEILING,DC=DROPCORD) 1� 011 _ C/DC CEILING MOUNTED QUADRUPLEX RECEPTACLE (C=FLUSHCEI,ING,DC=DROPCORD) u'u :IA C/DC CEILING MOUNTED DEDICATED QUADRUPLE{ RECEPTACLE (C=FLUSH CEILING, DC=DROPCORD) r� : C/DC CEILING MOUNTED QUADRUPLEX RECEPTACLE, SPLIT -WIRED (GFLUSHCEILING,DGDROPCORD) � N//IC/DC CEILING MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED (C=FLUSH CEILING,DC=DROPCORD) 277 CEILING MOUNTED PHOTOSENSOR ,'� BRANCH CIRCUITING, CONCEALED IN WALL OR CEILING C CEILING MOUNTED OCCUPANCY SENSOR � BRANCH CIRCUITING, CONCEALED IN OR UNDER FLOOR Y4'1 OS WALL MOUNTED OCCUPANCY SENSOR 277 50 BRANCH CIRCUITING, EXPOSED XXA inI �RACKLIGHTING LIVE END FEED; XX" INDICATES CURRENT LIMITER RATING IF APPLICABLE CW a� HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES THE NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE; SLASHES INDICATE NUMBER OF WIRES. GROUT` WIRE IS REQUIRED BUT NOT INDICATED. A 7 INDICATES ISOLATED GROUND CONDUCTOR, XXX RPS LOW VOLTAGE LIGHTING POWER SUPPLY/TRANSFORMER; "XXX" INDICATES VOLT -AMP RATING ® FLOOR MOUNTED TELEPHONE OUTLET; "P DENOTES NUMBER OF TELEPHONE PORTS WALL SURFACE ® C CEILING MOUNTED TELEPHONE OUTLET; "P DENOTES NUMBER OF TELEPHONE PORTS CWE CONDUIT STUB ® NE OUTLET,• "P DENOTES NUMBER OFALL MOUN'TED TTELEPHONE PORTS 1 %� VERTICAL CONDUIT/CIRCUIT V FLOOR MOUNTED DATA OUTLET; "D DENOTES NUMBER OF DATA PORTS B BELL C CEILING MOUNTED DATA OUTLET; "D DENOTES NUMBER OF DATA PORTS I-V BUZZER V WALL MOUNTED DATA OUILET• "D DENOTES NUMBER OF DATA PORTS WALL 7'-0" CHIME 7 FLOOR MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; "P/"D DENOTES NUMBER OF TELEPHONFIDATA PORTS ® SPEAKER, CEILING 7 C CEILING MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; "P/•D DENOTES NUMBER OF TELEPHONE/DATA PORTS -Q SPEAKER, WALL 7 WALL .P/"D DEOU ED COMBR ATIOF N� NFJODNEANDD TS DATA POR OG SPEAKER, GROUND -MOUNTED 3/4" THICK ONDRAWINGSWOODBACKBOARD, SIZEASINDICATED c===== V VOLUME CONTROL ( REMOTE TEMPERATURE SENSOR SOUND SYSTEM AMPLIFIERCO THERMOSTAT AMP TR LOW VOLTAGE CONTROL TRANSFORMER 102 REMOTE CARBON DIOXIDE SENSOR TC AUTOMATIC TIMECLOCK 0 PUSHBUTTON STATION, ONE BUTTON RELAY Q PUSHBUTTON STATION, TWO BUTTON R PHOTOCELL PUSHBUTTON STATION, THREE BUTTON PC lm LED EXIT SIGN WITH EXTERNAL KRYPTON LAMPS AND REMOTE CAPACITY, STENCIL FACE, WHITE, RED, HIGH OUTPUT LEAD -CALCIUM BATTERY CCTV SYSTEM LEGEND ABBREVIATIONS AND MODIFIERS (SOME MAY NOT BE USED) AFF ABOVE FINISHED FLOOR SPST SINGLE POLE, SINGLE THROW WP WEATHERPROOF MODIFIER AFG ABOVE FINISHED GRADE DPST DOUBLE POLE, SINGLE THROW PT POKE -THROUGH MODIFIER NIC NOT IN CONTRACT 3PST THREE POLE, SINGLE THROW H HORIZONTAL MOUNT MODIFIER UNO UNLESS NOTED OTHERWISE 4PST FOUR POLE, SINGLE THROW HG HOSPITAL GRADE MODIFIER N.F. NON-FUSED SPOT SINGLE POLE, DOUBLE THROW IG ISOLATED GROUND MODIFIER GFPE GROUND -FAULT PROTECTION OF EQUIPMENT DPDT DOUBLE POLE, DOUBLE THROW TR TAMPER-RESISTANT MODIFIER ST SHUNT TRIP MODIFIER SPDT THREE POLE, DOUBLE THROW SP SURGE PROTECTION MODIFIER GND GROUND 4PDT FOUR POLE, DOUBLE THROW GFCI GROUND -FAULT CIRCUIT INTERRUPTER EGC EQUIPMENT GROUNDING CONDUCTOR EM EMERGENCY LIGHT MODIFIER LED (INCLUDED) MODIFIER GEC GROUNDING ELECTRODE CONDUCTOR NL NIGHTLIGHT LUMINAIRE MODIFIER SR • SHOW WINDOW RECEPTACLE MOUNTED WITHIN AHJ AUTHORITY HAVING JURISDICTION +XX' MOUNTING HEIGHT MODIFIER 277 18 INCHES OF TOP OF SHOW WINDOW NEC NATIONAL ELECTRICAL CODE (NFPA 70) 1,3 B CR CONTROLLED RECEPTACLE MODIFIER LED (INCLUDED) 1 277 30 CH CLOCK HANGER RECEPTACLE CCTV SYSTEM LEGEND SYMBOL DESCRIPTION MI CCTV CAMERA, WALL EN C CCTV CAMERA, CEILING 0 CCTV CAMERA, DOME, CEILING PVM PUBLIC VIEW MONITOR SUPPLEMENTAL RACEWAY LEGEND • SYMBOL DESCRIPTION O P POWER POLE TELECOM POLE T TP TELECOM/POWER POLE - HT- HEAT TRACE /EM-- EMERGENCY CIRCUIT G UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, POWER - UCP - BREAK ROOM UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, TELEPHONE -UCT- J UNDERCARPET FLAT CONDUCTOR CABLE WIRING SYSTEM, DATA - U C D - T TELEPHONE RACEWAY,1/2" UNLESS NOTED OTHERWISE / TV TELEVISION RACEWAY,1/2"UNLESSNOTED ....„..-FA-...... NOTED OTHERWIEM RACEWAY, 112" UNLESS �S� SOUND SYSTEME RACEWAY, 1/2" UNLESS NOTED OTHERWIS rC, CLOCK SYSTEM RACEWAY,12" UNLESS NOTED OTHERWISE / IC NI O RCOM SS STTESME RACEWAY, 12" UNLESS /NC N RSEC LLSWISEMRACEWAY,12"UNLESS SEC SECURITY SYSTEM RACEWAY, 12" UNLESS NOTED OTHERWISE (1 j� WIRE LOOP FOR FUTURE CONNECTION, 10'-0" MINIMUM SLACK SUPPLEMENTAL ELECTRICAL. LEGEND SYMBOL DESCRIPTION A DATA ROOM B PHONE BOARD C CASH OFFICE AND VAULT D CEM (GENERAL MANAGER) OFFICE F OPS MANAGER G TRAINING OFFICE H BREAK ROOM I RECEIVING DESK PWR POLE DROP J REGISTER PWR POLE DROP K INFO STATION PWR POLE DROP L PRO SALES DESK PWR POLE DROP M TRAFFIC COUNTER N GE KIOSK P DESIGNER DESK PWR POLE DROP Q DISTRIBUTION POINT R ACCESS POINT WIRING S SELF SERVE DESIGN KIOSK PWR POLE DROP T COMMAND DESK PWR POLE DROP 0 DP u ,, D AND P JUNCTION BOX SINGLE CIRCUIT 0 DP D AND P JUNCTION BOX DOUBLE CIRCUIT EPARATE PERMIT REQUIRED FOR: t+ui'Meohanicai 0 Electrical dumbing t 4as Piping City of Tukwila 16.4`►_DING DIVISION IREVISIONS No changes shall he made to the Scope of work without prior approval of LUMINAIRE SCHEDULE MARK LUMINAIRE A VOLT WATT MOUNTING DESCRIPTION FOOTNOTES MAKE MODEL LAMP QTY Al2 LITHONIA IBG 12000LM HEF AFL 3ND 277 OZ10 40K 80CRI OCS15 SPD DWH IBAC120 LED (INCLUDED) 1 277 69 SUSPENDED 18'-0" 21"X15" LED HIGH BAY FIXTURE, 11746 LUMENS, SEMI- DIFFUSE ACRYLIC LENS, MEDIUM DISTRIBUTION, 0-10V DIMMING, 4000K, 80 CRI, GLOSS WHITE FINISH, INTERNAL SPD, RELOC WHIP ATTACHED, AIRCRAFT CABLE, WITH INTEGRAL OCCUPANCY SENSOR 1,3 Al2E LITHONIA IBG 12000LM HEF AFL 3ND 277 OZ10 40K 80CRI PS10250 OCS4C15 BPK SPD DM IBAC120 LED (INCLUDED) 1 277 69 SUSPENDED 18'-0" SAME AS TYPE Al2 ABOVE EXCEPT WITH 90 MINUTE EMERGENCY BATTERY BACKUP - 2400 LUMENS 1,3 A24 LITHONIA IBG 24000LM HEF AFL 3ND 277 OZ10 40K 80CRI OCS15 SPD DWH IBAC120 LED (INCLUDED) 1 277 133 SUSPENDED 18'-0" 26"X21" LED HIGH BAY FIXTURE, 23612 LUMENS, SEMI -DIFFUSE ACRYLIC LENS, MEDIUM DISTRIBUTION, 0-10V DIMMING, 4000K, 80 CRI, GLOSS WHITE FINISH, INTERNAL SPD, RELOC WHIP ATTACHED, AIRCRAFT CABLE 1,3 A24E LITHONIA IBG 24000LM HEF AFL 3ND 277 OZ10 40K 80CRI PS10 50 OCS4C15 BPK SPD DVNH IBAC120 LED (INCLUDED) 1 277 133 SUSPENDED 18'-0" SAME AS TYPE A24 ABOVE EXCEPT WITH 90 MIN EMERGENCY BATTERY BACKUP - 2400 LUMENS 1,3 A36 LITHONIA IBG 36000LM HEF AFL 3ND 277 OZ10 40K 80CRI OCS15 SPD DWH IBAC120 LED (INCLUDED) 1 277 197 SUSPENDED 18'-0" 47"X21" LED HIGH BAY FIXTURE, 35528 LUMENS, SEMI -DIFFUSE ACRYLIC LENS, MEDIUM DISTRIBUTION, 0-10V DIMMING, 4000K, 80 CRI, GLOSS WHITE FINISH, INTERNAL SPD, RELOC WHIP ATTACHED, AIRCRAFT CABLE 1,3 A36E LITHONIA IBG 36000LM HEF AFL SND 277 OZ10 40K 80CRI PS10 5O OCS4C15 BPK SPD DWH IBAC120 LED (INCLUDED) 1 277 197 SUSPENDED 18'-0" SAME AS TYPE A24 ABOVE EXCEPT WITH 90 MIN EMERGENCY BATTERY BACKUP - 2400 LUMENS 1,3 B LITHONIA 2BLT2 33L ADP EZ1 LP340 LED (INCLUDED) 1 277 30 CEILING LAY -IN 2'X2' LED LAY -IN TROFFER, 3313 LUMENS, SATIN WHITE LENS, 0-10V DIMMING, 4000K, 82 CRI 2 BE LITHONIA 2BLT2 33L ADP EZ1 LP340 EL14 LED (INCLUDED) 1 277 30 CEILING LAY -IN SAME AS TYPE B ABOVE EXCEPT WITH 90 MINUTE EMERGENCY BATTERY BACKUP -1400 LUMENS 2 C LITHONIA LBL4 LP840 LED (INCLUDED) 1 277 50 CEILING SURFACE 4' LED WRAPAROUND, 4600 LUMENS, #12 ACRYLIC LENS, 4000K, 82 CR1 2 CW LITHONIA WL4 40L EZ1 LP840 LED (INCLUDED) 1 277 39.5 WALL SURFACE 4' LED STRIP, 4325 LUMENS, SNAP -IN ACRYLIC LENS, 4000K, 82 CRI 2 CWE LITHONIA WL4 40L EZ1 LP840 ELI4 LED (INCLUDED) 1 277 39.5 WALL SURFACE SAME AS TYPE 'CW ABOVE EXCEPT WITH 90 MINUTE EMERGENCY BATTERY BACKUP -1400 LUMENS 2 0 FOSTORIA DKL 60VA LED LED (INCLUDED) 1 120 12 WALL 7'-0" 60" DOUBLE ARM DOCK LIGHT, LED, WIRE GUARD 7 DW LITHONIA LDN6 40/20 LO6AR LS5 MVOLT EZ10 TRW LED (INCLUDED) 1 277 22.6 CEILING RECESSED 6" LED DOWNLIGHT FOR EXTERIOR SOFFIT, 2023 LUMENS, WHITE FLANGE, SEMI -SPECULAR TRIM FINISH; ALSO USED IN CUSTOM MAPES CANOPY (REFER TO SHOP DRAWINGS) DWE LITHONIA LDN6 40/20 LO6AR LS5 MVOLT EZ10 TRW EL LED (INCLUDED) 1 277 22.6 CEILING RECESSED SAME AS TYPE 'OW ABOVE EXCEPT WITH 90 MINUTE EMERGENCY BATTERY BACKUP - 700 LUMENS ER LITHONIA ELA T QWP L0309 LED (INCLUDED) 2 277 /120 3 WALL SURFACE MOUNTED REMOTE LED EMERGENCY FIXTURE, GRAY HOUSING, TWIN ADJUSTABLE HEADS, WEATHER-PROOF, INSTALL ABOVE EXTERIOR DOORS FOR EMERGENCY LIGHTING 4,6 EX LITHONIA LHQM LED RHO LED (INCLUDED) 1 277 /120 3.3 WALL/CEILING SURFACE MOUNTED LED EXIT SIGN WITH EXTERNAL KRYPTON LAMPS AND REMOTE CAPACITY, STENCIL FACE, WHITE, RED, HIGH OUTPUT LEAD -CALCIUM BATTERY 5,6 F LITHONIA VGRIC 50LED MVOLTDWHG LPI LED (INCLUDED) 1 277 /120 50 WALL MOUNTED INTERIOR LED SCONCE FOR PROVIDING AMBIENT LIGHTING FOR ROOF HATCH LADDER, LOCATED ADJACENT TO LADDER AT 18'-25' AFF G LITHONIA TZL1 N L96 6000LM FST 40K MVOLT 80CRI WH. LED (INCLUDED) 1 277 /120 60 CEILING SUSPENDED INTERIOR 8' LED STRIPLIGHT FOR SUSPENSION MOUNT IN UTILITY OR STORAGE ROOMS; AVAILABLE IN 4' LENGTHS K INTENSE MBMG2 L3.41 B 32 PS 27 1PS8B271 IPS208B / IPS201B27 IPS213611PS30B / IPS1208 IPS3416 (CUSTOM) LED (INCLUDED) 1 277 /120 20 TRACK MOUNTED LED HEADS TRACK SUSP. AT 12'-0" AFF LED TRACK HEADS FOR LIGHTING DESIGN CENTER; 2120 LUMENS, 4100K, 32DEG BEAM; 1 HEAD PER 4' LINEAR TRACK; FOR VIGNETTES WIDER THAN 4'-0", USE 2-3 HEADS. 1A AND 5A CURRENT LIMIITERS NEEDED; CABLE MOUNTING KITS SPACED EVERY 4'-0" FOR SUPPORT M LF ILLUMINATION LF20-02307-05 (LED MODULE + HOUSING) LF40-00748 (REMOTE DRIVER) LED (INCLUDED) 1 277 20 CUSTOM MOUNT IN MAPES CANOPY IP67 RATED DOWNLIGHT FOR MAPES CANOPY; TYP. 4 LIGHTS PER CANOPY - GC TO CONFIRM QTY; 4000K, 1000 LUMENS; REMOTE LED DRIVER WILL POWER UP TO 4 LIGHTS; DRIVER NOT OUTDOOR RATED; VERIFY WITH SHOP DRAWINGS PRIOR TO ORDERING RL LITHONIA ZLIN L48 5000LM FST 277 40K 90CRI MB RFD207699 LED (INCLUDED) 1 277 42 RACK MOUNTED IN -RACK LIGHTING FOR SINK DISPLAYS, MOUNTED WITH RIVETED MAGNETS TO UNDERSIDE OF RACKING PER DRAWING DETAIL, CONNECTED TO RELOC SYSTEM VIA CABLES PROVIDED SL LITHONIA KAX2 LED P2 40K RX NVOLT SPA DDBXD LED (INCLUDED) 1 277 248 POLE/TENON MOUNTED AREA LIGHT FOR PARKING LOT, MOUNTS DIRECTLY TO POLE OR TENON ADAPTER AT 20'-35 AFF, 34000 LUMENS SLP HUBBELL SSS S 25 50 B TA DB NIA N/A N/A N/A ANCHOR BOLTS IN CONCRETE PEDESTAL SQUARE, STEEL, STRAIGHT POLE AVAILABLE IN ANY HEIGHT FROM 20'-40', BOLT PATTERNS AVAILABLE FOR MOUNTING MULTIPLE AREA LIGHTS T LITHONIA ELMLT W LPO6VS LTP LED (INCLUDED) 2 277 /120 1.4 WALL SURFACE MOUNTED LED EMERGENCY FIXTURE, WHITE 5,6 V LITHONIA DMW2 L24 4000LM PCI WD MVOLT GZ1 40K 80CRIQMB LED (INCLUDED) 1 277 /120 40 CANOPY SURFACE LED ROUGH SERVICE FIXTURE, 4855 LUMENS, MOUNTED TO UNDERSIDE OF PRO LOAD CANOPY VIA QUICK -MOUNT BRACKETS PROVIDED W1 LITHONIA DSXW2 LED 30C 1000 40K TFTM MVOLT DDBXD LED (INCLUDED) 1 277 109 EXTERIOR WALL 18'-0" LED WALL PACK FOR EXTERIOR SITE LIGHTING ALONG SIDES AND REAR OF BUILDING, 4000K, DARK BRONZE, 11443 LUMENS, 70 CRI W2 LITHONIA WSR LED 2 10A700 40K SR4 MVOLT DDBXD LED (INCLUDED) 1 277 47 EXTERIOR WALL 7'-0" LED DECORATIVE SCONCE, MOUNTED ALONG MAIN ENTRANCE TO STORE FOR AMBIENT LIGHTING, 4000K, DARK BRONZE, 3851 LUMENS, 70CRI X LITHONIA EXR LED EL LED (INCLUDED) - 277 /120 1 SUSPENDED LED EXIT SIGN, STENCIL FACE, WHITE, RED, NICKEL CADMIUM BATTERY 5,6 FOOTNOTES: USING 'RELOC ONEPASS' MODULAR WRING SYSTEM. 8. TRACK LIGHTING IS FED VIA RELOC SYSTEM. MUST USE DESIGNATED 2H/2N/IG PORT USING 'RELOC SYSTEM 820' MODUL4R WIRING SYSTEM OR HARD -WIRED. TO CONNECT 'OD' CABLES AND HARD WIRE INTO LIVE END FEEDS OF TRACK. CABLE MTG THIS SHEET 'SUSPENDED HIGH BAY INSTALLATION'. KITS ARE SPACED 4'-0" O.C. ALONG TRACK FOR SUPPORT. MAX CABLE LENGTH IS 16'. HIGH -OUTPUT BATTERY OF NEARBY 'EX' FIXTURE. IF LOWEST MOUNTING POINT IN CEILING IS ABOVE 27'-0' AFF, CONTRACTOR MUST UN -SWITCHED CONDUCTOR OF CIRCUIT IDDICATED. PROVIDE MEANS OF SECURING THE CABLE KITS SO THE TRACK SUSPENDS AT 12'-0' AFF. 'EXIT AND EMERGENCY FIXTURE INSTALLATION' . BY RECEPTACLE AND CONTROLLED BY SWITCH. SEE 'POWER PLAN'. I. FIXTURE POWERED 2. FIXTURE POWERED 3. SEE DETAIL 4. CONNECT TO 5. CONNECT TO 6. SEE DETAIL 7. FIXTURE POWERED i Tukwila Building Division. NOTE: E-. visions will require a new plan submittal and may include additional plan review fees. $ E COPY Permit Noe l C / C� q 7 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any ado code or ordinance. Receipt of approved Field p conditions is acknowledged: By: City of Tukwila BUILDING DIVISION ELECTRICAL GENERAL NOTES: I. ELECTRICAL DESIGN SHALL COMPLY WITH LOCAL ADOPTED CODES OR 2014 EDITION OF NFPA 70, WHICH EVER IS MORE STRINGENT. 2. ELECTRICAL CONTRACTOR SHALL REFER TO ALL OTHER DESIGN DRAWINGS PRIOR TO BID AND RETAIN FULL UNDERSTANDING OF THE SCOPE OF WORK. 3. REFER TO THE ARCHITECTURAL/INTERIORS REFLECTED CEILING PLANS FOR EXACT FIXTURE PLACEMENT AND DIMENSIONS. 4. REFER TO THE ARCHITECTURAL/INTERIORS DOCUMENTS FOR ACTUAL DEVICE LOCATIONS AND DIMENSIONS. 5. ALL CEILING MOUNTED DEVICES (FIRE ALARM SYSTEM DEVICES AND SPEAKERS, SOUND SYSTEM SPEAKERS, ETC.) TO BE SYMMETRICAL ABOUT LIGHT FIXTURES AND SPRINKLER HEADS. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR DEVICE PLACEMENT AND DIMENSIONS. 6. THE COLOR/FINISHES OF ALL ELECTRICAL DEVICES, OUTLETS, COVER PLATES AND TRIM WITH THE ARCHITECT UNLESS OTHERWISE NOTED. 7. REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF WORK. 8. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN RACEWAYS. 9. ALL HOME RUNS SHALL RUN PARALLEL TO STRUCTURE AS MUCH AS POSSIBLE WHERE CEILING IS EXPOSED. HOME RUNS SHALL BE LOCATED AS CLOSE TO THE ROOF DECK AS POSSIBLE. 10. COORDINATE ALL RACEWAY AND EQUIPMENT SUPPORTS WITH STRUCTURAL DRAWINGS TO ENSURE HANGER LOCATION OCCURS WITHIN FOUR (4) INCHES OF PANEL POINT ON BAR JOISTS. II. COORDINATE LOCATION OF ALL FLOOR MOUNTED MECHANICAL AND PLUMBING EQUIPMENT IN ORDER TO VERIFY POWER 8 CONTROL RACEWAYS ARE CONCEALED IN SLABS AND TERMINATES AT PROPER LOCATION (NOTHING CONCEALED IN SLAB. 12. DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT INSTALLED ABOVE ACCESSIBLE CEILINGS THAT REQUIRE ACCESS FOR MAINTENANCE, SHALL BE INSTALLED 1'-0' ABOVE CEILING TO PROVIDE READY ACCESSIBILITY. 13. COORDINATE WITH M/P/FP CONTRACTORS AND CONTRACT DRAWINGS/SUBMITTALS FOR EXACT LOCATION OF EQUIPMENT. MECHANICAL, PLUMBING, FIRE PROTECTION, AND OTHER EQUIPMENT ARE SHOWN ON FLOOR PLAN IN APPROXIMATE LOCATIONS. 14. REFER TO STRUCTURAL AND ARCHITECTURAL PLANS FOR ELEVATION CHANGES AND RACEWAY ROUTES. RACEWAY INTERCONNECTIONS OF EQUIPMENT, FIXTURES, AND DEVICES ARE INDICATED ON FLOOR AND REFLECTED CEILING PLANS ARE GENERAL OUTLINE. 15. WALL MOUNTED EXTERIOR LIGHTING RACEWAYS MAY BE INDICATED OUTSIDE OF BUILDING FOOTPRINT FOR CLARITY. ROUTE ALL EXTERIOR LIGHTING RACEWAYS WITHIN BUILDING STRUCTURE. 16. PROVIDE SURGE PROTECTION FOR FIRE ALARM CONTROL PANEL, ELECTRICAL SERVICE AND TELECOMMUNICATION SERVICE. 17. FIELD COORDINATE MECHANICAL AND PLUMBING EQUIPMENT REQUIREMENTS FOR ANY SUPPLEMENTAL POWER REQUIREMENTS, INCLUDING BUT NOT LIMITED TO CONTROL CIRCUITS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING ALL EQUIPMENT TO ITS INTENDED OPERATIONAL STATUS. 18. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS OF FLOW AND TAMPER SWITCHES. 19. EACH CABLE, WIRE OR CONDUIT PENETRATION OF A FIRE RESISTANT RATED ASSEMBLY SHALL BE PROTECTED BY A THROUGH PENETRATION FIRE STOP SYSTEM THAT HAS BEEN TESTED ACCORDING TO ASTME 814 OR E199. FIRE STOPPING SYSTEM SHALL MATCH RATING OF FIRE RESISTANT ASSEMBLY. 20. ELECTRICAL RECEPTACLES, SWITCHES, OUTLETS, ETC. SHALL NOT BE INSTALLED BACK TO BACK ON FIRE RESISTANCE RATED WALLS. THEY SHALL BE AT LEAST 24 INCHES APART. 21. LIGHT SWITCHES AND ELECTRICAL OUTLETS IN ROOMS ACCESSIBLE TO THE DISABLED SHALL BE LOCATED NO HIGHER THAN 48' A.F.F. AND NO LOWER THAN 15' A.F.F. IF THE REACH FOR CONTROL IS OVER AN OBSTRUCTION, THE MINIMUM HEIGHT SHALL BE REACHED TO 44" A.F.F. FOR A FORWARD APPROACH OR 46' A.F.F. FOR A SIDE APPROACH. 22. ELECTRICAL BOXES INSTALLED IN FIRE RATED WALLS SHALL MAINTAIN THE INTEGRITY OF THE RATED WALL. 23. SUPPORT ALL VERTICAL RACEWAY PER NEC TABLE 300.19(A). 24. RECEPTACLES SERVING ELECTRIC WATER COOLERS SHALL NOT SHARE A NEUTRAL AND BE A GFCI PROTECTED OUTLET. THE OUTLET AND CORD SHALL NOT BE VISIBLE FROM PUBLIC VIEW. 25. CONTRACTOR SHALL RELOCATE UP TO FIFTEEN (15) LIGHT FIXTURES WITHIN 10'-0" IN ANY DIRECTION TO ACCOUNT FOR RACKING RELOCATIONS AT NO ADDITIONAL COST. 26. LIGHTING VENDOR (CED NATIONAL ACCOUNTS) SHALL PROVIDE A SPECIFIED PACKAGE WHICH INCLUDES ALL LUMINAIRES AND AIRCRAFT SUPPORT CABLE. IF THE PROJECT IS A FLOOR AND DECOR PROJECT, THE TOTAL LIGHTING PACKAGE WILL BE OWNER PROVIDED. IF THE PROJECT IS BY A DEVELOPER, THE LIGHTING PACKAGE IS TO BE CONTRACTOR PROVIDED. FOR PRICING, ORDERING, AND GENERAL QUESTIONS, CONTACT SHAWN CAMBELL AT 678-215-3065 OR SHAWN.CAMPBELL@CED.COM. 27. ALL SUSPENDED LUMINARIES TO BE HUNG USING AIRCRAFT CABLE AT HEIGHT SHOWN IN FIXTURE SCHEDULE, UNLESS NOTED OTHERWISE. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, INVENTORY, STORAGE, AND INSTALLATION OF ALL OWNER FURNISHED LIGHTING. 29. CONTRACTOR SHALL COORDINATE SHIP DATES AND OTHER REQUIREMENTS WITH VENDOR. 30. UNUSED FBO MATERIALS MUST BE PALLETIZED, SHRINK WRAPPED AND RETURNED TO VENDOR IN GOOD CONDITION FOR FUTURE TENANT USE. 31. ALL LUMINAIRES MUST BE FREE FROM ALL DEBRIS AND LENSES WIPED CLEAN AFTER COMPLETION OF THE PROJECT. 32. MINIMUM WIRE SIZE FOR LIGHTING AND POWER CIRCUITS SHALL BE #10 FOR ALL 20A BRANCH CIRCUITS. WIRE SIZES SHALL BE SIZED SO THAT THE VOLTAGE DROP WILL NOT EXCEED 3% AND THE TOTAL VOLTAGE DROP FROM THE SERVICE ENTRANCE TO THE FURTHEST DEVICE DOES NOT EXCEED 5%. 33. LIGHTING IS CONTROLLED BY AN EMS SYSTEM. REFER TO SHEET E501 FOR MORE INFORMATION. 34. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING DESIGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATE PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. 35. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH -IN. 36. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO ROUGH -IN. THIS INCLUDES, BUT IS NOT LIMITED TO, MECHANICAL EQUIPMENT, KITCHEN EQUIPMENT, AUDIO/VISUAL EQUIPMENT, FIRE SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM EQUIPMENT, ETC. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE THE APPROPRIATE DISCONNECTING MEANS FOR, AND TO MAKE THE FINAL CONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE CORD AND PLUG FOR ANY CORD -AND -PLUG CONNECTED EQUIPMENT THAT IS NOT EQUIPPED WITH AN INTEGRAL CORD AND PLUG. 37. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED THROUGH CONTACTORS OR RELAYS FOR CONTROL. 38. ALL EQUIPMENT, DEVICES, AND LUMINAIRES SHALL BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED. EQUIPMENT MOUNTED OUTDOORS SHALL BE NEMA 3R. DEVICES MOUNTED IN DAMP OR WET LOCATIONS SHALL BE WEATHERPROOF. RECEPTACLES RATED 15- OR 20 -AMPS AND 120 VOLTS WHICH ARE LOCATED IN DAMP OR WET LOCATIONS SHALL BE GFCI PROTECTED AND EQUIPPED WITH A SUITABLE WEATHERPROOF COVERPLATE (WHILE -IN -USE IN WET LOCATIONS). 39. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C CONDUCTORS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED. 40. CIRCUITS SERVING EMERGENCY LIGHTING EQUIPMENT SUCH AS EMERGENCY BATTERIES SHALL NOT SHARE A NEUTRAL (SHALL NOT BE PART OF A MULTIWIRE BRANCH CIRCUIT) WITH ANY OTHER CIRCUIT. PROVIDE A SEPARATE NEUTRAL FOR EVERY CIRCUIT THAT SERVES EMERGENCY LIGHTING EQUIPMENT. 41. ALTHOUGH NOT SPECIFICALLY SHOWN, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED LOW VOLTAGE WIRING AND DATA CABLING, PER THE MANUFACTURER'S RECOMMENDATIONS, FOR A COMPLETE, FUNCTIONAL LIGHTING CONTROL SYSTEM. REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC JAN 08 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC O' 8 2017 PERMIT CENTER las En eering Ass Consu Phone: 602.992.3900 Fax: 602.9921541 809 W. Maryland Ave. Phoenix, AL 85013 les, Inc Iamle@LJglasenp.com Engineers TEA #16201 SAKE REINDERBMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizona 85255 p: 480.515.5123 www.sra360.com 4J V ce 4J C 0 COX 00 JW t�0 CD GO as cn relN CO GO cq .) En rn is C `JO cs s 8 L (A CD � � 9 I 110g fej C -4 rl 0. CD date: 8-10-2017 issued for: PERMIT SUBMITTAL revision no.: date: A A A A job no. : 17-027 sheet title: ELECTRICAL NOTES sheet no.: E002 INTEGRATED SWITCHBOARD MSB BY SCHNEIDER ELECTRIC (INCLUDES ALL EQUIPMENT SHOWN IN ENCLOSURE). TO 800/3 DISCONNECT AND METER PROVIDED BY LANDLORD UNDER SEPARATE PERMIT KIRK KEY INTERLOCK p //// 2 SETS OF 4 - # 500 KCMIL, EACH SET IN 3" CONDUIT 800/3 #1/0 G.E.C. SEE DETAIL I/E003 - 800/3 MAIN DISTRIBUTION PANELBOARD "MDP", 277/480 VOLT, 3 PHASE, 4 WIRE, 800 AMP BUS MDP -I 2 SETS OF 4 - #500 KCMIL, #1/0 GROUND EACH SET IN 3" CONDUIT j 45/3 MDP -2 45/3 MDP -3 CP, 45/3 MDP -4 45/3 MDP -5 45/3 MDP -6 45/3 MDP -7 45/3 MDP -8 45/3 MCP -9 45/3 MDP -I0 ®Ij 30/3 MDP -II MDP -12 �j 30/3 �D 30/3 MDP -13 D 20/3 MDP -14 ®j 200/3 MDP -15 j 45/3 MDP -16 j 70/3 MDP -17 j 30/3 0-2 SETS OF 4 - #500 KCMIL, #1/0 GROUND EACH SET IN 3" CONDUIT GENERATOR TAP BOX LANDLORD ELECTRICAL ROOM a- 3 - #6, #10 GROUND IN 3/4" CONDUIT ONE LINE DIAGRAM d-- 3 - #6, #10 GROUND /,/ IN 3/4" CONDUIT 1 -/Ig RTU -2 d-- 3-#6, #10 GROUND / / IN 3/4" CONDUIT RTU -3 NOT TO SCALE FLOOR & DECOR ELECTRICAL ROOM NOTE: MODIFIED OR REPLACED SERVICE ENTRANCE SECTION AND UTILITY METER TO BE PROVIDED BY LANDLORD UNDER SEPARATE PERMIT. VERIFY REQUIREMENTS WITH LANDLORD'S ELECTRICAL CONTRACTOR PRIOR TO ROUGH IN. GENERATOR TAP BOX SERVICE ENTRANCE SECTION 800/3 DISC. SWITCH OR/ CIRCUIT BREAKER O PNL H1 O O O 0 0 MSB 0 O 0 PNL L1 O 0 O O TRANSFORMER T -L1 45KVA 480-208/120V PRI ,- 3-#6, a- 3-#6, #10 GROUND #10 GROUND /,/ IN 3/4" / / IN 3/4" CONDUIT CONDUIT RTU -4 RTU -5 d— 3 - #6, #10 GROUND /,/ IN 3/4' CONDUIT L/Ig RTU -6 ,r- 3-#6, ,- 3-#6, #10 GROUND #10 GROUND / / IN 3/4" I. / IN 3/4° CONDUIT CONDUIT RTU -7 UNISTRUT CHANNEL; USE CHANNEL SELECTION CHART TO DETERMINE CHANNEL TYPE; TYPICAL OF TWO (5) POWER WALL ELEVATION NOT TO SCALE UNISTRUT CHANNEL NUT DRY -TYPE TRANSFORMER PRIMARY CONDUCTORS IN FLEXIBLE METALLIC CONDUIT TO PANELBOARD BELOW UNISTRUT CHANNEL BASE RAIL; USE CHANNEL SELEC770N CHART TO DETERMINE CHANNEL TYPE; TYPICAL OF TWO BAR JO/ST 1/2" DIAMETER THREADED ROD; TYPICAL OF FOUR SECONDARY CONDUCTORS IN FLEXIBLE METALLIC CONDUIT TO PANELBOARD BELOW UNISTRUT #P1000T BASE RAIL CROSSBEAM; TYPICAL OF TWO UNISTRUT CHANNEL; USE CHANNEL SELECTION CHART TO DETERMINE CHANNEL TYPE METAL DECK Tkr TOP CHORD OF 1.1 BAR JOIST DOUBLE HEX NUT UNISTRUT FLAT PLATE F1777NG 1/2" DIAMETER THREADED ROD TO BASE RA/L BELOW NOTE: WHERE PRACTICAL, A BEAM CLAMP MAY BE USED AS AN ALTERNATE MOUNTING METHOD TO THIS ASSEMBLY. BEAM CLAMPS SHALL BE ATTACHED TO THE TOP CHORD OF THE Il BAR JOIST. DRY -TYPE TRANSFORMER MOUN77NG FOOT MASON INDUSTRIES SUPER K PAD 2" x 2" x 3/4" VIBRATION ISOLATOR CHANNEL SELECTION CHART MARK MAXIMUM TRANSFORMER WEIGHT BY CHANNEL PI000TDF P3000TGR P5500TDF UNSUPPORTED SPAN DISTANCE 24 INCHES 1417 LBS 1072 LBS 2728 LBS 36 INCHES 873 LBS 669 LBS 1613 LBS 48 INCHES 597 LBS 462 LBS 1025 LBS 60 INCHES 425 LBS 340 LBS 686 LBS 72 INCHES 312 LBS 258 LBS 465 LBS 84 INCHES 237 LBS 200 LBS 323 LBS 96 INCHES 175 LBS 149 LBS 224 LBS 108 INCHES 135 LBS 109 LBS 152 LBS TRANSFORMERS GREATER THAN 50 KVA ARE NOT PERMITTED ABOVE CEILINGS 1/2" DIAMETER THREADED ROD TO UNISTRUT HANGER ABOVE HEX NUT UNISTRUT FLAT PLATE RUING UNISTRUT FLAT PLATE F/T77NG DOUBLE HEX NUT BOLT THROUGH TRANSFORMER MOUNTING FOOT TRANSFORMER IVOU\ UNISTRUT FLAT PLATE FI777NG DOUBLE HEX NUT TING DETAIL NOT TO SCALE NOTE: mounting detail to be verified by structural engineer for site specific installations. UNISTRUT #P1000T BASE RAIL CROSSBEAM UNISTRUT CHANNEL BASE RAIL; USE CHANNEL SELECTION CHART TO DETERMINE CHANNEL TYPE RTU -8 PRIMARY CONDUCTORS IN FLEXIBLE METALLIC CONDUIT TO PANELBOARD �— 3-#6, #10 GROUND L / IN 3/4" CONDUIT 1;13 R1U-9 d-- 3 - #10, d-- 3 - #10, d— 3 - #10, d- 3 - #12, #10 GROUND #10 GROUND #10 GROUND #12 GROUND I,/ IN 1/2" / / IN 1/2' / / IN 1/2" / / IN 1/2" CONDUIT CONDUIT CONDUIT CONDUIT L.:1g /ll RTU -II RTU -12 RTU -13 d-- 4 - #3/0, #6 GROUND IN 2" CONDUIT PANEL "HI" #8 G.E.C. SEE DETAIL 2/E003. — 3-#8, #10 GROUND IN 3/4" CONDUIT MrY1 TRANSFORMER T -LI 30KVA 3 PHASE, 480 VOLT DELTA PRIMARY, 120/208 VOLT WYE SECONDARY 4 - #3, #8 GROUND IN 11/4' CONDUIT 60/3 PANEL "LI" 3-#10, #10 GROUND IN 1/2" CONDUIT C.- 4#6, 1#10 GND. PANEL "L3" #6 G.E.C. SEE DETAIL 2/E003. - a- 3 - #4, #8 GROUND IN I" CONDUIT w�J TRANSFORMER T -L4 45KVA 3 PHASE, 480 VOLT DELTA PRIMARY, 120/208 VOLT WYE SECONDARY 0-- 4 - #1/0, #6 GROUND IN 2" CONDUIT 60/3 PANEL "L4" 1" C.- 4#6, 1#10 GND. PANEL "L2" DRY TYPE TRANSFORMER SCHEDULE MARK PHASE PRIMARY SECONDARY kVA RATING K FACTOR MANUFACTURER CATALOG NUMBER WIDTH DEPTH HEIGHT WEIGHT WEATHERSHIELD MOUNTING DETAIL T -L1 3 PHASE 480V DELTA 120/208V WYE 30 kVA NONE SQUARE D EX30T3H 25.5" 21" 35.32" 400 LBS. NO INTEGRAL TO SWITCHBOARD T -L4 3 PHASE 480V DELTA 120/208V WYE 45 kVA NONE SQUARE D EX45T3H 25.5" 21" 35.32" 490 LBS. NO 4/E004 GENERAL NOTES: A. ALL TRANSFORMERS SHALL HAVE ALUMINUM WINDINGS UNLESS NOTED OTHERWISE. B. ALL TRANSFORMERS SHALL HAVE CLASS 220 INSULATION SYSTEM UNLESS NOTED OTHERWISE. C. ALL TRANSFORMERS SHALL HAVE VENTILATED ENCLOSURES UNLESS NOTED OTHERWISE. D. ALL TRANSFORMERS RATED 15 KVA AND LARGER SHALL MEET DOE 2016 EFFICIENCY REQUIREMENTS. E. WHEN TRANSFORMER IS LOCATED REMOTE FROM THE DISCONNECTING MEANS, THE ELECTRICAL CONTRACTOR SHALL PROVIDE A PERMANENTLY INSTALLED LOCKING MEANS AT THE DISCONNECT AND FIELD MARK THE LOCATION OF THE DISCONNECTING MEANS ON THE TRANSFORMER. 3" THICK CONCRETE HOUSEKEEPING PAD; PAD SHALL EXTEND 3" BEYOND TRANSFORMER ON SIDES AND FRONT AND SHALL EXTEND 6" BEYOND TRANSFORMER IN REAR c, WATER P/P/NG IN AREA --� TRANSFOR V WALL BEHIND TRANSFORMER DRY -TYPE TRANSFORMER SECONDARY CONDUCTORS IN FLEXIBLE METALLIC CONDUIT TO PANELBOARD MASON INDUSTRIES ND SERIES NEOPRENE VIBRATION ISOLATOR FOR TRANSFORMERS MOUNTED ABOVE SLAB ON GRADE; SECURE TRANSFORMER TO VIBRATION ISOLATOR, IF APPLICABLE, AND SECURE VIBRATION ISOLATOR TO HOUSEKEEPING PAD; TYPICAL OF FOUR ER MOUNTING DETAIL NOT TO SCALE TRANSFORMER OVERCURRENT PROTECTION 30 PANEL • l m • .J L TRANSFORMER PRIMARY CONDUCTORS EQUIPMENT GROUNDING CONDUCTOR LJ BUILDING STRUCTURAL STEEL MEMBER SYSTEM BONDING I SIZED PER NEC DBLE 250.102(C)(1) 0 MAIN OVERCURRENT PROTEC770N 30 PANEL INSULATED NEUTRAL BAR 30 DELTA PRIMARY, 30 SECONDARY DRY -TYPE TRANSFORMER J 11 ■ �r BOND THE BUILDING STRUCTURAL STEEL TO THE GROUNDING ELECTRODE CONDUCTOR USING A UL LISTED IRREVERSIBLE CLAMP OR LW 3 EQUIPMENT GROUND BAR SUPPLY-SIDE BOND/NG JUMPER SIZED PER NEC TABLE 250.102(C)(1) TRANSFORMER SECONDARY CONDUCTORS; TOTAL LENGTH SHALL NOT EXCEED 25'-O" PER NEC SEC770N 240.21(C)(6). GROUNDING ELECTRODE CONDUCTORS SIZED PER NEC TABLE 250.66 DRY—TWE 2TRANSFORME� NOT TO SCALE NOT SCALE GROUND DETAIL G.T. CABINET OR OTHER SERVICE ENCLOSURE BONDED TERMINAL BLOC NOTE I - FOOTING jr J 0 NOTE I SERVICE DISCONNECTING MEANS (NOTE 8) BONDED NEUTRAL BC/5- MAIN BOND/N6 BONDED EQUIPMENT GROUND E1/ EQUIPMENT GROUND/N6 CONDUCT(' TYPICAL SUB -PANEL GROUNDED SERVICE ENTRANCE CONDUCTGx NOTE 2 (TVP) PROTECTIVE SLEEVE 0 0 NOTE 9 - ••••• 4 A NOTE 3 -/311 NOTE 7 NEUTRAL BGS (NOT BONDED 1-#6 A BOND/N6 .NJMPER 'I. PER NPPA 54 SECTION 7.13 GROUNDED CONDUCTORd �#6 AW6 IN/tx5Y5TEM BOND/N6 CONDUCTOR I HOUSE -SIDE ABOVE -GRADE 6A5 PIP/N6 /. NOTE 4 0 E10(TYP.) NOTE 5 -, METAL 1./141,ER6ROC/ND {11, 47ER PIPE GENERAL NOTES APPLICABLE TO THIS DETAIL: A. FOR CLARITY, PHASE CONDUCTORS ARE NOT SHOWN. NOTE 6 TYPICAL BRANCH \CIRCUIT NOTE 7 G., --UNDERGROUND 6A5 PIPE 6A5 METER WHEN PRESENT TELEGOMMUN/GAT/ONS SYSTEM BACKBOARD BUILDING STRUCTURAL STEEL. MEMBER WHEN PRESENT NOTES APPLICABLE TO THIS DETAIL: I. ALL METAL CONDUITS ENCLOSING ANY SERV/CE CONDUCTORS SHALL BE FITTED WITH A BONDING BUSHING. SIZE THE JUMPER PER NEC ARTICLE 250. 2. ALL METAL CONDUITS ENCLOSING ANY GROUNDING ELECTRODE CONDUCTOR SHALL BE FITTED WITH A BONDING BUSHING AT EACH END. SIZE THE JUMPER PER NEC ARTICLE 250. 3. PROVIDE AT LEAST ONE SUPPLEMENTAL GROUNDING ELECTRODE PER NEC IN THE FORM OF A 10'-0' x 3/4' COPPER CLAD GROUND ROD INSTALLED PER CURRENT NEC ARTICLE 250 REQUIREMENTS. 4. CONNECT TO THE BUILDING'S METAL UNDERGROUND WATER PIPE WITHIN 5'-0' OF ITS ENTRANCE INTO THE BUILDING AND JUMPER ANY WATER METER PER NEC REQUIREMENTS. 5. IF STRUCTURAL STEEL MEMBER IS AVAILABLE, BOND IT TO THE SERVICE USING A UL LISTED IRREVERSIBLE CLAMP OR WELDED LUG. 6. PROVIDE AN EQUIPMENT GROUND BAR AND ATTACH IT TO THE PHONE BOARD. 7. ALL BRANCH CIRCUIT AND FEEDER CONDUITS ARE TO HAVE AN INSULATED EQUIPMENT GROUNDING CONDUCTOR REGARDLESS OF THE CONDUIT MATERIAL. 8. WHEN THE SERVICE CONSISTS OF MULTIPLE DISCONNECTING MEANS IN SEPARATE ENCLOSURES, CONNECT A TAP CONDUCTOR FROM THE MAIN GROUNDING ELECTRODE CONDUCTOR TO EACH DISCONNECTING MEANS. SIZE THIS TAP BASED ON THE LARGEST SERVICE CONDUCTOR IN THAT SERVICE DISCONNECT ENCLOSURE. 9. PROVIDE A GROUNDING ELECTRODE ENCASED IN AT LEAST 2' OF CONCRETE AND LOCATED NEAR THE BOTTOM OFA CONCRETE FOUNDATION OR FOOTING THAT IS /N DIRECT CONTACT WITH EARTH. GROUNDING ELECTRODE SHALL CONSIST OF AT LEAST 20'-0' OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2' IN DIAMETER OR AT LEAST 20'-0' OF #4 AWG BARE COPPER CONDUCTOR. THIS CONCRETE ENCASED GROUNDING ELECTRODE IS ALSO KNOWN AS A 'LIFER' GROUND. 10. WHERE A GROUNDING ELECTRODE CONDUCTOR IS SPECIFIED ELSEWHERE IN THE DRAWINGS, THAT SIZE SHALL APPLY TO ALL GROUNDING ELECTRODE CONDUCTORS SHOWN ON THIS DETAIL. SERV I GE ENTRANGE GROUND ETA I L NOT TO SCALE ELIC REVIEWED FOR COMPLIANCE WITH NFPA70-NEC JAN 0 8 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0' 8 2017 PERMIT CENTER TigNas Engineering Lamle@U9lasen0.cem Associates, inc TEA #1szo1 Consulting Engineers Phone: 602.992.3900 Fax: 602.992.1541 809 W. Maryland Ave. Pheenlx,AL 85013 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizona 85255 p: 480.515.5125 www.sra560.com C O U V 0 L 0 C 6 0 dote: 8 -IO -201' Issued for: PERMIT SUBMITTAL revision no.: dote: A Job no.: 17-021 sheet title: ONE LINE DIAGRAM sheet no.: 003 CENTER OF SLIDING DOOR OVERLAP LOW VOLTAGE POWER & CONTROL WIRING CONTROL BOX RECEPTACLE HIDDEN FROM VIEW 1/2" CONDUIT WITH PLASTIC BUSHING & PULL WIRE PEDESTALS, LV WIRE, WIRE MOLD, CONTROL BOX & FLOOR PATCH BY VENDOR / / FEED 4' WIRE WHIP INTO POST EAS PEDESTALS, BOLTED TO FLOOR FL SI4" MOUNTED/ /JB9X // WIREMOLD 1/2" WIDE x 1-1/2" DEEP SAW CUT IN SLAB IH m `-III 4'T ti EAS FE ESTAL DETA I L NOT TO SCALE HI -2,4,6, (3#/0,/#10 GND.) KEYED NOTES: I. INSTALL /20V QUICK CONNECT JUNCTION BOX FOR MODULAR WIRING CONNECTIONS TO POWER POLE. QUICK CONNECT DISTRIBUTION BOX WILL BE FURNISHED BY THE OWNER. REFER TO D8P CUSTOM LIGHT AND POWER PACKAGE FOR ADDITIONAL INFORMAT/ON. 2. J -BOX FOR EXTERIOR SIGNAGE TO BE INSTALLED ON INTERIOR OF FRONT WALL. SIGN VENDOR WILL PROVIDE PENETRATION AND WIRING OF ELECTRICAL SIGNAGE. ELECTRICAL CONTRACTOR TO PROVIDE FINAL CONNECTION OF WIRING AT J --BOX. ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION AND COORDINATE ALL REQUIREMENTS WITH SIGN VENDOR PRIOR TO ROUGH -IN. PROVIDE AN APPROPRIATE LOCAL DISCONNECTING MEANS MOUNTED IN AN ACCESSIBLE, INCONSPICUOUS LOCATION THAT IS WITHIN SIGHT OF THE SIGN. EACH SIGN CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND SEPARATE EQUIPMENT GROUNDING CONDUCTOR. 3. PROVIDE DISC. SWITCH AND FINAL CONNECTION TO AUTOMATIC DOOR OPERATOR AND INTERLOCK WITH ALL ASSOCIATED PUSHBUTTONS AND MOTION SENSING APPURTENANCES. COORDINATE ALL REQUIREMENTS WITH EQUIPMENT MANUFACTURER PR/OR TO ROUGH -/N. 4. PROWDE DISC. SWITCH AND FINAL CONNECTION TO OVERHEAD DOOR OPERATOR AND INTERLOCK WITH ALL ASSOCIATED PUSHBUTTONS AND MOTION SENSING APPURTENANCES. COORDINATE ALL REQUIREMENTS WITH EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN. 5. HEAT TRACE FOR ROOF WATER HYDRANT. COORDINATE WITH PLUMBING CONTRACTOR. 6. NOT USED 7. WEATHERPROOF GFCI SERV/CE RECEPTACLE IS PROVIDED BY EQUIPMENT MANUFACTURER INTEGRAL WITH EQUIPMENT. RECEPTACLE IS FACTORY WIRED INTO UNIT POWER SUPPLY. 8. PROVIDE LOCKABLE WEATHERPROOF WHILE -IN -USE COVER. 9. PUBLIC VIEW MONITOR. PROVIDE 40' WHIP WITH DUPLEX RECEPTACLE ON END. COIL WHIP AT CEILING FOR SECURITY CONTRACTOR'S USE. 10. PROVIDE FINAL CONNECTION TO SECURITY PEDESTALS. COORDINATE ALL REQUIREMENTS AND EXACT LOCATION WITH SECURITY VENDOR PRIOR TO ROUGH -IN. II. CONTRACTOR SHALL SAWCUT FLOOR TO PEDESTALS. REFER TO EAS PEDESTAL DETAIL 5/E/0I FOR ADDITIONAL INFORMATION. C� NSTALL IN OWNER FURNISHED DISTRIBUTION BOX 2 ENLARGED POWER PLAN E101 SCALE: 114"=1'-0" NOTE 7 4 hIRESHOLD L2-3 +44" TMB PANEL "L2" 16,18,20 1 10,12,14 NOTE 7 NOTE 7 NOTE 7 I—II- RTU-9 --II � SE RT •9 SE• ONELINE DIAGRAM LI MDP RTU -8 SEE ONELINFL DIAGRAM IIIEf-1 ' \/ /\ \H/-32,34 36,38,40,4 (6#/0,/#/0 CND) Or I 1 L J MDP RTU -7 SEE ONELINE DIAG —. In NOTE I 4 10 NOTE I 4 1 P 7 NOTE / NOTE I PANEL 'L4' L2-10,12,14, N NOTE-' NOTE IF LJ RTU -11 ELINE LJ RTU -6 MDP SEE ONELIN DIAGRAM WAREHOUSE 104 NOT r /\/I\/I\/ N L%/\/\ N j/\/\\% 1\/\/\// \/'./ /! \/i\/\//_ /\'\,/ ./_ \,1/\/_\!/N ! 1\ t v /, . /I\ /v 7 v7!\ /I\ /Iv / /A1/\/\/ \ /\ VI/\/\ /\I/\/\/\ v/\/v7\7 �'71II\/ /1 /\/ 77] % v/ v/V.,�7 vi V I/ y/ \ ! \/\/\/\/ \//\/\/ N/\/\/:\/ 1 As/\I/\I/\ /AI'\!!\I/\1 /\/\/V,/V! /IV /\ /i\ \ 7 ,/N/N7 '\ /\ /\ /,A /1 / \I/ VI/ \i/\ / \,' \ / \/ \! / \:/ V!/ \i/ \I \ /i\ /i\ /I\ / \ /'. /I\/,\/ ;\/,\/1\7\7 i/\/\/\;/N, /VI 'V'/\/` /\i/\/\1/ /i\ /\ /IA N /� , /1\ /V %i !\ /I\ /\ %\ I \I/N/NV !/\,•\I/\V /\/\I/\/ 1 /y /.y /Iv 7 Iv y /iN /I ;\ /y /1\ 1/\,/\;/\17,„; ,/\,-\,/\,/\I i/A!/AI/A,/\I ,/\/\/\/\.; 'N/\/'\/\/ \71 /I\/ \7 \/\/\/\7 /\I/\/\'/ \ \I/\/\ /\/\/\/\, \7\/V/\t1 /I ,/i'NOT'/ \/\/\/\/! '/N/NN/N1 VV '\/\!/V . /A!/\I/\/\I /i\/\/:A/ i\/ ,/\/v/! IN/\/\/iV/ !/\!/\I/\/ASI /VI'V!/A/\I 10 /\I/\/\/\I �y/�v/1v/;A/, ;y/1v7' 1v/,v/� , ! N/Ni/V./N E171 N/y/\ /v✓v, 1 07 \ /i\ /I\ /\ /I N7 /\ /i\ / L1-10,12,14,/'\ /\ /\ / / A!/\I/\/N /AI'\/V,/\1 / V/\!/\/\ /\/I\/\/ /I /\/\//i \/\/I\/1\/ ,,,,,,,// \/ \\/\VNO '/V /\I/\!/N /\/\/A✓N \/I\/\/\V/1,/,\ /i\ \%V/I\/'\ / \I/ \I �i \I \/ \r/ \I NOTE/7V/ N/ \/ 1y/i\/\/\/'� /I /v/\/ \/\/\/I\7 / \1/ \!/ A / \i / \! \!/ \i / \i / \/ \ / N7 \I \ v,/I\ /\%I :Tut \ /I\ /! ,\ /\_ / U / V!/ \!/ \/ \I % V!.' \/ y!/ V LJ l'"'"-/"Y\'//\I SEE�ONECINE/ \ /\/\/i\/ \/'./1\/\/I RTU -5 \ V \�/ \/ V!/ � 1/\; At \/ \I/ \, LDIaGRAMi \/ NOTE I 14 i 14 \/&/I\/\/ N7\/\/\t T`. i . / / \L'\I/\/ /\/ N/N/\ \/ I /\/-\/\7\/\/ ..//'. /\'/\:/\!/\I/N 1 -1\/1./\/\/N/\/\/\/ 7-7' \'/' v7_ v,'/ -v /-\ / \/-",-i .�_.L /:\ G .C..\ /\ GJ._./ Zi /,\ /\./\/\I/N/\/\;/\ i 1i \%j A/N/\/N/\/1 / N =77-7/ / \/-"C'7 \I v/y/7_, /7/1 .V\/\•/\1\/\/\;/N NOTE 7 \ I I l-1 1-1-- -1 i vvvv/ !v/, ,/I\/! \/iv/!\/vTi /\_'/\/\�_/\!-?— „,,r,/,,,,, /Ai/\!/\/_A�,I C\71\71\7\71 I\/ /i\/I\/ N/N/\/.\/i ,/,. .„,,,,/ / \/ \I/ \/ N /i7,/I\/i\/! .,/i\/i\/\/ /\%\I/\/ /\!'\I/\/\ /\!/\I/\I/_I P\/!v/\/\�I \/ �./\/y/ v/\/\/�,/ /\I/\!/\! I/\' '\/\!/N /\/\I/\I/\ /\/V /1./i\/\/i \/\/!\/\/ V\/,\/_/\/\ /\i /\ \f\/\ \/\I/\I/ /\ f �v / y /I /�N / /v/Ni/y/N (_11.1 /N/N //y/ JIJ \/\/I\/\/'� \/./I\/\/ i \/\/N/i\/ / \/VI/V'/_� vi, \/,,/, ▪ \'/\/\/_1 N/!\/\/'V�I„71,71,7,/ 'I /I\/\/\�I ✓ \/\I/\/\I /V '\i/Vii /\I/\/V!/\I \%!\/\/V/ !\/ ./i\/\ti iA/i\/\/\/1 IV/i\/i\/�A/r',/,..\,');›,/,/,\.,<> ,,▪ 7,7.A/A/ /\!/\/V'/_' /\ • \,!V!/\I I \/\/\/_A �N/v/Iy/A/i CCS 1_ jA/`.71 /N/ Litt>j I/ \i/ \i/ \,,,,\I / \,' \/ \i/ \! / \'/ \/ \I/ _! y/vI/y/y, I v'v!/vI/y/yiv/y/ ! /I\/1\/'\/, 1 / 1/'\/i\/i \/\/\/IV i !/\/\!/\/\. /\ '\/\!/\i ./\/\/\,,\J t\ \ /\/\/V/ IN/ /\/\/ NOTE - 7\/\/V-. E/ I,/\/\I/\/ \/\/i\/\7 6 I\ , 7 i _.� NOTE 7 I' 11. I I _ lI r -II 11 NOTE 111 1 L t v� - SNOT 7 5 NOTE I RTU -1O NOTE 5 LINE 1 T LI, . MOP -1 I g L \RTU 3 SEE AGRAME ONELIIIIE L \/\!/\'/\ \ /\/\i/\I /\/\/\l/\! N/Iv/N/y/ ; 7 ;v7y/ ! N/N/N/Iv/ NOTE I NOTE / 23,27__._._ LI -'.5_ L J MDP RTU -2 SEE ONELINE DIAGRAM // 021,27 j' \ L1-21 \✓: 15 NOTE 9 1/\I/\/\/\ N/A/\/I\/ /\/\/\I/\1 v 7\7\ 7\ v/J -r-. y/v/ ..•2, / .L'J\7-/ MDP, ;(71 / \!I' \.RTU'4 \''/ \/SEE/ONNEMLINE v/ v/1v/v/� / \!/ \!/ \/ \I %\/\/i\/ /\/\I/\/N1 N/\/I\/i\/! /\/\/\ /\/\/\/_ ! N/\/\/N, /\/\I/\I/\! \ /N /I\ /\ /I /\/\'/\!/\ \ /\ /I\ /\ /I /A!/\/\I/\I \ /V / \ /I\ / 1 /\/\I/\I/\ :/v./I\/\/ \/\/\/\I I\/\/\/I\/ \/\/I\/i\/I \/\/\/ _ I /\/V/\7 /\,/\/\/\ \ 7\1\ /i\ \/\/\iNt /1)V6TE/ /\;/\/\;/ \!! /\/\/\/I N7TE I v V\ /v 4v,'y / i -:r / \,/ 7/ Al/ A /T1 ,/:.‘_, /L7y..7 A /iv_G ,7 I _LI L /N'\/AZN/\/NVN 24 _N7 •\/\/N/\/\/N/ J. \!/\/\/\1/\/N -'\/f;V\/`\/\/\/\/I 241 i\ / 7 \ \ / \/ N/ \,L7-22,24 / N.7 \/N\I/\ NOTE7 /\/V/\/\/ v./v/\1y1 v/A G. \• L J MDP RTU -1 SEE ONELINE ,\ /DIAGRAM \ \\/ NOTE 1 7 L3-13 PANEL 'L3' L3-9 NOTE I LI -271 L3-7 LI -15,17,19 F1 NOTE 3 I Nd TE /'J NOTE I 6 UH -2 NOTE 6 OTE NOTE 2 NOTE 3 NOTE I NOTE 2 NOTE 4 L3-2,4,6 i I I t--,' GFCCWP, 'NOTE 8 ti GFCI,WP, NOTE 8 J L1-16,18,20 1 OVERALL POWER PLAN E101 SCALE: 1116"=1'-0" ENERATOR TAP BOX. L1 -3I NEW INTEGRATED SWITCHBOAI REFER TO ONE LINE DIAGRAM ADDITIONAL INFORMATION. WP/GFCI FOR IRRIGATION CONTROLLER. VERIFY LOCATION AND REQUIREMENTS WITH IRRIGATION CONTRACTOR. u a I 1:0:1 r.ro:1 L3-1,3,5 Rl 8 z G) I 11 3 ENLARGED POWER PLAN E101 SCALE: 114"=1'4I" PLUG AND PLAY J -BOX FURNISHED BY OWNER, INSTALLED BY ELECTRICAL CONTRACTOR, MOUNT WITHIN 6" OF TRUSS. VOICE/DATA CABLES (AS REQUIRED) 2 -CHANNEL POWER WITH EXTENSION ARM. CONNECT TO STRUCTURE ABOVE AND FOOT BRACKET AT FIXTURE, PROVIDED AND INSTALLED BY OWNER. P1000 UNISTRUT CHANNEL SECURLY FASTENED TO BOTTOM OF TOP CHORD OF BAR JOISTS. ROOF STRUCTURE U.L. LISTED POWER CABLES (E.6. RELO AND INSTALLED BY CABLE SUPPORTED FT PER NEC. FONER FOLE CONNECTION NOT TO SCALE ELI/ 'WED FOR IANCE WITH A7A-NEC )IS34 021d JAN 0 8 2010 City of Tukwila — BUILDING DIVISION RECEIVED CITY OF TUKWI► DEC 41"'8 2017 PERMIT CENTER TEnglignelearinSg Associates, inc Consultlng Engineers Phone: 602.992.3900 Fax: 602.992.1541 809 W. Maryland Ave. Phoenix, AL 85013 TEA #16201 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 p: 450.515.5123 60, u. . -6,44 8 twos; „to, eLL Poe MX CD 1,m la CD lid Ha RIM oti c,6 CO co CO cc oml pia lin dote: 5-I0-201' Issued for: PERMIT SUBMITTAL revision no.: dote: A Job no.: 11-021 sheet title: FLOOR PLAN - POWER sheet no.: SI SI S I S I AI SI AI S I 1 CU 12AWG CONDUCTORS __. """"„"`, TYPICAL MWS CONTROL MODULE OVERVIEW (OPEN CEILINGS) NOT TO SCALE NAME ABBV DESCRIPTION DISTRIBUTION BOX PRIMARY DBP J -BOX WITH (12) ONEPASS STARTING CONNECTIONS. NOT ALL CONNECTIONS ARE USED. 2 PORT CABLE OC2 MAIN CABLE USED TO EXTEND ONEPASS CIRCUIT RUN. HAS (5) CONDUCTORS, (3)#12 FOR POWER (SWITCHED HOT, NEUTRAL, GROUND) & (2)#18 FOR CONTROL (0-10V, HOT NEUTRAL) SPLITTER SPLICE OSS SPLITS A ONEPASS CIRCUIT RUN IN TWO DROP CABLE OD HAS LOOSE WIRES ON ONE END FOR CONNECTION TO LIGHT FIXTURE. OTHER END CONNECT TO EXTRA PORT ON UNDERSIDE OF '002' DBP 00 00 00 0C2 OSS MODULAR WIRING SYSTEM (MWS) (OPEN CEILING) NOT TO SCALE 5 WI 5 WI 5 WI 1111E7 = 31U 5 I .'"Su11•1111=r 211111 5 WI '002' EXTRA PORE OR 'OSS' 'OC2' (TYPICAL) MWS DBP' MAINRUN--\\ n n rl� CABLES - El --S ELECTRICAL PANEL SALES 'OD' /'SUSPENDED LIGHT / FIXTURE c(,-JBOX FOR TRANSITION ONEPASS-m\\ Luu MWS MAINRUN CABLES TO OTHER 'DBP'S VAREHOUSE MODULAR WIRING SYSTEM DIAGRAM NOT TO SCALE 5 WI DIAGRAM IS GENERIC. SEE VENDOR PROVIDED DRAWINGS FOR COMPLETE, PROJECT SPECIFIC SYSTEM LAYOUT AND COMPONENTS B WI 5 WI 5 WII LAY -IN LIGHT FIXTURE SECURE MWS CABLE TO BOTTOM CORD OF BAR JOIST. ATTACH 'UNISTRUT' TO TOP OF BOTTOM CHORD OF JOIST WITH APPROVED FASTENERS. ATTACH TO MINIMUM TWO JOISTS. UNISTRUT BETWEEN JOISTS SALES AREA FIXTUR AIRCRAFT CABLE TOP OF FIXTURE NOTES: A. CONTRACTOR TO PROVIDE ALL HARDWARE AND CABLING NECESSARY FOR INSTALLATION. B. LIGHT FIXTURES THAT RUN PARALLEL WITH THE JOISTS SHALL REQUIRE TWO (2) SEPARATE PIECES OF 'UNISTRUT', ONE (1) AT EACH END OF LIGHT FIXTURE FOR THE AIRCRAFT CABLE HANGERS. TIE MWS CABLE SECURELY TO AIRCRAFT CABLE AND LIGHT FIXTURE FOR SNUG FIT WITHOUT UNNECESSARY SAG ACCESS PLATE CONNECT POWER AND DIMMING CONDUCTORS TO FIXTURE RUN CABLE THROUGH OPENING IN STRUT SUPPORT, LOOP AROUND AND ATTACH SECURELY WITH 'GRIPPLE' HANGERS ON VERTICAL LINE OF CABLE. MODIFY CABLE TO CORRECT LENGTH IN FIELD. SUSPENDED HIGH BAY INSTALLATION NOT TO SCALE A24 A24 A24E A24 A24 A24E A24 A24 A24E A24 WI 33 ImI 412 33 T 412 33 111 412 33 ir'1 412 412 33 11 412 33 41412 33U 4 AI2E AI2E 33 A24 24E A24 2 I.. I\/\/\/\ �� ��J� \/-./\/\/ KT7R7I\71 436 RJ17i\/\71 , I -/\I/\ /\ /\ I/\I�� J/J/\ �T ,l\il 1\/1;/7/1771 I/J/V���/vNJ/\I I/vI'\VAI/v�i (\ /�\ 71\ 71 71 IHIIan \7\71 Ii v7\i IT yI' - -1-T / vL_ / A36E I\71-7,...\, \ �I A36 J� 71\ %J1 A36 1-171\1<71-\\I/W\ 1< % -II A24 /I\/l��l IRA1T71\A\�I R/R/�\/T/ /v /\I/v /v /\I'v /vI/vI /\ /v/vI/v �7I\T7i\�i iy/I.»vT1 ,-1'—v y � 1 115 /\I/A/v/v�) 15 /\I'vI/\/V 17U I/\I/vI/vI/v-I 1I' A36 7T/ \ / 7I \ 71 1i' 436 K 71 7R T I I A36E /\ 1\\ 7 /\ / \ /A / \ ii./..:.1‘4/_,,,L;.41. \/\/\/\/ I/-%TT7 \l// 1\ i\I 1\1\/1\/1\/1 I/\ /\I/\I/\ 17 /I\ / uuupra I7V 1r/\1177r11\7177 I E- �_E-s l_-13 L\LJL\L\ILJ!JLJ'J 9,91) //,/3,131/ \/1\/1\1\71 II--/ \ / \I/\1/ "I R/1\1\71\1 /\1/\ /\/\ 7;71RZR71 L'JL`_LJI 71\1x1 717174 '\I!_ILJ WI A36 A36 I\/\/\/\/ 436 r iR /-i\ \ i•\_/1 /\TT v/ ./A/\/ \1Z .1Z. 871.71\/I\1 71 .; \/R/ '\I/\I \ 7\;7- / \/1\7811 r I ' JL JL JI 1\/ \ 15 '' 15 J1 V NI (TYP) 33U AI2E \ %I\. /I I/y/vI/vI/v1 A36E 1/I\777\71 F/1y/1y; yA 33U I X I xi XI XI XI 7 XI 33 I X I N 5 WI 5' I WI I1436 mo— I\/I\/I\/I\7— -----\/./\/1\// A24 1/v /v /\ /\I /\ /\ /\ 19 v/IV71\/y19 / .%1V/\i 19 v/JA_J/�\�__JJ 1i 436 I /1\71\/I\/I A36 K. 1= A36 LT71\71V/I /V /\I/v /\ /v \I/v /vI /\LA /\I/vI �7I\;,\�I\ 871 ;,\7r;�, 1\�I\; 7\/ I/\I/\/v/v�� /vIA�I/�_\I/v LAI/vVvI/v 171/1\/1\71 R/1,ZR71\/, I\/\7RR/I\/I la T / 21_IST --' 21 A24 VAVA /vI/\I L IA11111�/v\I/v-II 1' I-/AI/\LIII)ilj 436 17717/1\ 71\ 436 1\71 /1\71\1 A36 /I/\71\71 A36 \TTT7i i\1//T 71\71 1\T71\/I\ 1 I /\I/\I/\ /\ /\ 'J/\I/\ 1\/'. 1\� I\ ,.7R/1 A36 A36 A36 II /I\l\T /\/\I /\1/\I/\1/\ 19 A36 Piz A36 \ /1\ /1\7F,71 21 _ �'✓v '\1l• 21 33U " AI2E R/_7i\/i\A T iT H. 7 / \I/ \V AV AI pH/ %\i\ 1 v/v/vTi v1v/ \I/\/\I A36 V\�,/�\ I\ /I\ 1771\1 A36E I 1/\I/ 71 A36E \T/ f�71\71\71771 IT/F71\7 /AI/\I/\I/yI V\1/\VvI/N 21 21 /v'"v/ 21 1/\VJ/vLvI I/v1vI/vI/v /\/\Ii"Lvl 71\ /I\ iI\/I I\ /I \ 71\ T /I I\ /I\ /I\ /I\ /I /v/v/v/v \717;1171 �LJL/J 412 33 4 412 33 412 33 412 33 Xc3�— A36_� ei•� A36 =35,37 25 A24 A24E ii AI2E 33 1u' 412 33 A36 A36E (TYP) WI A24 A24 37 D L_ DW DW DW TRACK CONNECTION WITH 5A CURRENT LIMITER 0 SHEET KEYNOTES 1 PROVIDE ALLOWANCE TO RELOCATE FIFTEEN (15) LIGHT FIXTURES 10' IN ANY DIRECTION TO ACCOUNT FOR RACKING RELOCATIONS AT NO ADDITIONAL COST. 2 EXIT SIGNS TO BE CONNECTED TO UNSWITCHED CIRCUIT AS SHOWN. 3 MANUFACTURED WIRING SYSTEM DISTRIBUTION BOX; SEE DETAILS ON SHEET E102a. 4 ROUTE ALL LIGHTING THRU EMS CONTACTOR PANEL. REFER TO SHEET E501. 5 THE EXTERIOR EMERGENCY FIXTURE 'ER' IS TO BE CONNECTED TO THE HIGH OUTPUT BATTERY OF FIXTURE "EX'. H/-1,3,5 TRACK CONNECTION ITH 1A CURRENT LIMITER (TYPICAL FOR 4) 0 SHEET KEYNOTES 6 COMPACT LED STRIP LIGHTT MOUNTED IN RACK. REFER TO DETAIL ON SHEET E102a. 7 MWS SPLITTER FOR RACK LIGHTING. SEE DETAIL 7/E102a. (TYP) CE CARL LIGHTING CIRCUITS OUT TO FIXTURES -CONTROLLED BY POWER PACKS SS (SPLITTER LIGHTING CIRCUITS OUT TO NEXT ROOM / AREA - UNSWITCHED TYPICAL MWS CONTROL MODULE OVERVIEW NOT TO SCALE ROOF STRUCTURE 1/2" G.R.M.C. SECURELY ATTACHED TO JOIST PENDANT MOUNTING BRACKET 1/2' G.R.M.C. THREADED ON BOTH ENDS. PAINT WHITE. ELECTRICAL CONTRACTOR SHALL MOUNT EXIT LIGHTS IN SALES AREA 1'0" TO TOP OF SIGN BELOW GENERAL LUMINAIRE MOUNTING HEIGHTS. SRFACE MOUNT TO WALL OR SUSPENDED CEILING IN AREAS WITH SUSPENDED CEILING. EXIT SUPPORT DETAIL NOT TO SCALE I S I SI SI % I SI SI %I \/\/\/\/\/\, MWS SPLITTER 31' MWS CABLE - MAGNET (TYP) 11' MWS CABLE BETWEEN BAYS REVIEWED FOR COMPLIANCE WITH FPA 70 - NEC MWS CONNECTOR TO LIGHT FIXTURE—+. - FLOOR • TYPE Al TYPE R1 JAN 08 2018 City of Tukwila BUILDING DIVISION RACK LIGHTING NOT TO SCALE KEYED NOTES: I. LIGHT FIXTURE TO BE MOUNTED WITHIN RACK. SEE RACK LIGHTING DETAIL 2/E102 FOR ADDITIONAL INFORMATION. 1 LIGHTING PLAN E102 SCALE: 1116" =1'-O" ELI 2. EXTERIOR EMERGENCY FIXTURE "TYPE ER" WILL BE CONNECTED TO THE HIGH OUTPUT BATTERY OF FIXTURE "TYPE EX'. RECEIVED CITY OF TUKWiLA DEC 0'8 2017 PERMIT CENTER Tigas Engineering Associates, Inc Phone: 602.992.5900 Fax: 602.992.1541 809 W. Maryland Ave. Phoenix, AL 85013 )amle©tlglaseng.com Consulting Engineers TEA #16201 SAKE REIN DERSMA ARCHITECT 5450 e. high street suite: 200 phoenix, orizono 55255 p: 450.515.5123 www.sra360.com E u cV Q � c.) In CD C) 5f .43U CD aft' O V 8 U L 0 2610 irc Q CD me lad idia os ID v CAD imd roe, -- - 6 0 date: 8-I0-201' Issued for: PERMIT SUBMITTAL revision no.: dote: A Job no.: 17-021 sheet title: FLOOR PLAN - LIGHTING sheet no.: 02 II II II II i 1 Y WAP® II u L5 u Y T r rt (� WAP -- - TO RTU-// NOTE2- gE m� typLi gWAP�j RTU -10 TO RTU -/O NOTE2- NOTE 9 J C NOTE 6 S 0 NOTE l 2) 1 61 Li S OF -I 2 1 I WA? i • TO RTU -6 NOTE 2 1 0 WAP TO RTU -3 NOTC I O 1 3 NOT t (RT f /Rl)1TU�)/I I\1\/1\T1 RT1\/1\1 I\T/i\T1 \/ \1\1\/ TO Fel U-8 NOTE 2 r /1\/I \/I \/ 1 C WAP 1v/r./Iv' )/I I/\_\I/\I/\ 17/ 5/1\71 I\ i7 1/\ '\ /\I/\I \Ti1 \./r\./.1 VN 17/ 1/v '\I/vI/v 1\TT/I\1 F/1'.71\T1 I / /KAN/ N/ SAN rT/I\/ZRA \+.'71\17/ 1 I/vL/_ 1,_/ x� _ir/-Ni 4II/vI/�-_ T T_ Iv/I\/1VAN/1 O 1 1/\\I\/\1 R \ / N/ \/N1 I/\I/\I/\I/\ 1,7_777.17.717 / VZRA\7T 71 I\1NT1-\1 R1\/T/T/I I/\I/\I/\-L/\=I \ \ \/I\/I 1\ /\I/\I/\I/\ I\TT1\1 NOTE7J/I\ ZR T 1 (RTS' 4 RUIRTUtb NOTE 5 0 NOTE / NOTE I NOTE 5 NOTE / NOTE 8, \/ ./ \/\/I RT1 /1 ./1\AZil \I V1 I/ \I \l/ \I --7-7-&-71771•771- 111111111. v / y I\/1 ./Iv/IV1 r\/ .1\1\1 i /11,ZR ;1 1/\1)"\i/_1 -/I ITITf�lily z v /I /\I N/ F 571\ .1 IN/1 /1 17171\/1\71 �;.A/Iy71 J \l/\l/1\ T /\ /\ R1 /I\1N1 IN;N 71N71 r\/II\7\ZR/ 81\1\1\1 \I/\I \/R/ \Z\71 1.\/1\,/ \./I\/ 1/.1/\l/.1/\1\ I\\ \1\\71 u u CD V;-/;ZRA1 I/\I/\ r\/r/I /\I/\LIIIIIIO® 1\71\1\/I 1/\I/\J/\V\-I 1\/\/1\1\1 VT//A\il II U /I I/\I/.. /vI/\ RANANAN1 RAN i\ AN A 1/ \l/ 1/1/\L'"" 1v1v1v1\/I 1/NI/NI/NI/NI 1\7\1\1\1 /.\i/vl/\I!\I i\TT1\A I/v/v/\I/\I 1y71 -y /J111111111) _ -4-- \j/ NA/ I\/�\1\il\/1 V1 -EZ ->\)I I\%til\ l\/ 1\A\1\AN/1 I.TSLj/\I/N, V \I NOTE1I 11111111111111111111111 FAIVAIIVA NOTE 5 TO RTU -2 NOTE 2 -NO /t 9 C ID \T, / '1\1\/1 -/\I/\V\I/\I N1\1\T/1 I/ r\. -1\-/r\/1\/1 \__„_.1/ \_„1/ /\I/\ F/1\// \A\A 17/ N/N / I/\I/\I/\JJ/\I \1/ 71 I\ A\ 1\/ \ it \-1-1/1/1/771\1 \ \ I/AN/v.1 NOTE 5 771777217 NOTE2- I O ErZRARTAR71 AAR7l\1 L/�L'JL yL yIVJLyIL/\L J [R7.1F/r 1fy 7R 117 = a I T LSIJLLJI!JLJLJ NOTE 5 ®W` i /r.1R/r1R7RAR7171 TO RTU NOTE 2 "I L v 'JLvI/NV. vI/JLJ!J O ER Ctil 1\7711\7/(\/ i 1 MI j \ �I\ /T\ /II\ /I\ /II\ /I\ /I NOTE 5 EB LJI'JLL"_II! JL\VJ \I/\ _a\\ I//\I/\I/1 I\/ \T/ \/ I!\I!\i/\I/ AZZR\I I\A A I/vI/v/vI/\I I\A\/1\ /I\ /I /\/\I/\/\I \/ \T/1\A 1/\ /\I/\I/\I r•;/I\1\ZRA 1{�/\T/JI N/\;1/Z/ INAZAZi1\1 1\/1\1\ZRA 1/\ \I/ \I/ \I 0 0 l 1 0 0 17 71 17\7117\771F771 ' •. 71. 1 L yL4yILNI/NIIVyVNIIVyLJ 17.711\7F711\7711\ L\I NV .V IL \I 0 1217.7117 77 711\ T Ar\ 71771 TO RTU-/ NOTE 2 ' ©I 1 ' l_- _LJL=L`-IL_L I l ) lin MI ▪ IN 111 I O 1 SYSTEMS PLAN E103 SCALE: 1116" m 1'4" EIVOICE/DATA DROP LEGEND DATA CONTRACTOR'S SCOPE OF WORK TO INCLUDE: VOICE/DATA CABLING (CAT 5 & FIBER), VOICE/DATA TERMINATIONS, VOICE/DATA PATCH PANELS, VOICE/DATA COVER PLATES WITH WIRE LANDING TERMINATIONS LABELED AT PATCH PANEL & LOCATION. A. DATA ROOM (BOX -A AND BOX -S) (BLACKBOX WILL BE PROVIDED BY F&D) I. LOCATION OF MAIN DISTRIBUTION POINT 2. BOX -A (TWO POST RACK) AND BOX -S (SERVER BOX) 3. BOXES MUST BE GROUNDED TO BUILDING STEEL, #6 AWG COPPER, MIN 4. 1-6 STRAND FIBER PATCH PANEL WITH LC TERMINATIONS WILL BE MOUNTED AT THE TOP OF BOX A.. LABELING WILL BE LI & L2. FIBER WILL BE RUN FROM A TO BOX B. (BY OWNER'S CONTRACTOR) 5. IF NOT MIN POINT OF ENTRY THEN 4-CAT5E CABLE WILL NEED TO BE RUN FROM MPOE TO THIS ROOM (CHECK DISTANCE). (BY OWNER'S CONTRACTOR) 6. ALL RUNS, IF UNDER 250 FT, WILL TERM HERE. NO MORE THAN 44 RUNS CAN PATCH INTO THIS BOX. 7. SERVER BOX (BOX -S) 24"X36" TO BE MOUNTED ON WALL 42' FROM BOTTOM OF BOX TO FLOOR, CENTERED ON LEFT SIDE WALL AS YOU ENTER THE ROOM. 30" OPEN ON EACH SIDE FOR ACCESS. I DEDICATED CIRCUIT QUAD MOUNTED IN BACK OF SERVER BOX (INSIDE ENCLOSURE). 9. 1-24 PORT PATCH PANEL FOR SERVER BOX, LABELING SCHEME: SI, S2...(10 TOTAL CABLES FROM BOX S TO BOX A). (BY OWNER'S CONTRACTOR) 10. 10 CAT 5E FROM BOX A TO BOX S NEED TO BE RUN AND PUNCHED DOWN ON BOTH ENDS. (BY OWNER'S CONTRACTOR) PROVIDE (2) YC FROM BOX -A & BOX -S UP TO STRUCTURE (WITH PULLWIRE) & GROMMETS. 8. B. MIN PoE PHONE BOARD/MPOE NEEDS TO BE IN PLACE AS EARLY AS POSSIBLE TO ALLOW AT&T TO INSTALL TI (MINIMUM 2 WEEKS BEFORE SUBSTANTIAL COMPLETION). C. CASH OFFICE & VAULT D. CEM (GENERAL MANAGER) OFFICE E. NOT USED F. OPS MANAGER G. TRAINING OFFICE H. BREAK ROOM J. K. L. M. N. 0. P. Q. RECEIVING DESK CASH REGISTERS INFORMATION STATIONS - NEW STORES (3 LOCATIONS), REMODELS (# DETERMINED ON PLAN), PROFESSIONAL SALES DESK TRAFFIC COUNTER (ONE ABOVE EACH CUSTOMER ENTRY DOOR AND PRO -SLIDER) GE KIOSK (CREDIT KIOSK) NOT USED DESIGNER DESK DISTRIBUTION POINT (BOX B) (BLACKBOX WILL BE PROVIDED BY F&D IT OR OPS) PROVIDE 2-3°C FROM BOX -B UP TO STRUCTURE (WITH PULLWIRE) & GROMMETS. 2. DISTRIBUTION POINT (BOX B) MUST BE GROUNDED TO BUILDING STEEL (#6 MIN). R. ACCESS POINT WIRING (ACCESS POINT LOCATIONS SHOWN FOR PRICING PURPOSES ONLY AND SHALL BE VERIFIED WITH PREDICTIVE SURVEYS PROVIDED BY F&D) S. SELF-SERVICE DESIGN KIOSK T. COMMAND DESK HARDWARE PROVIDED BY F&D -NETWORK BOX A -NETWORK BOX B -SERVER BOX S 10-12 CISCO ACCESS POINTS WITH ANTENNAS -ALL 3 BLACK BOXES (BOX A,B & 5) NEED TO BE MOUNTED PER PLAN, WITH HOT POWER OUTLETS IN EACH BOX. BOXES NEED TO HAVE CONSTRUCTION DEBRIS REMOVED (SAWDUST, WIRE CLIPPINGS, ETC). GENERAL ELECTRICAL NOTES: A. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING DESIGN, ALL EQUIPMENTAND MATERIALS ATER ALS INSTALLED WITHIN THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATE PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. B. ALTHOUGH NOT SPECIFICALLY SHOWN, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED LOW VOLTAGE WIRING AND DATA CABLING, PER THE MANUFACTURER'S RECOMMENDATIONS, FOR A COMPLETE, FUNCTIONAL LIGHTING CONTROL SYSTEM. C. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LOW VOLTAGE DATA CAT 5E AND FIBER CABLES. FINAL TERMINATIONS BY OWNER'S DATA CONTRACTOR. D. PROVIDE 25' SERVICE LOOP FOR EACH CABLE AT THE TOP OF EACH POWER POLE UNLESS OTHERWISE NOTED. D. ALL OTHER CABLES SHALL HAVE A 20' SERVICE LOOP UNLESS OTHERWISE NOTED. E. ALL VOICE AND DATA CABLING SHALL BE CAT5E UNLESS NOTED OTHERWISE. KEYED NOTES: I. PROVIDE CONNECTION TO D&P BOX. 2. REMOTE TEMPERATURE SENSOR FURNISHED AND INSTALLED BY OTHERS. PROVIDE ALL WIRING BETWEEN SENSOR, THERMOSTAT, RTU, AND EMS SYSTEM AS REQUIRED FOR A FULLY FUNCTIONAL CONTROL SYSTEM. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR AND EMS PROVIDER PRIOR TO ROUGH -IN. 3. CARBON DIOXIDE (CO2) SENSOR FURNISHED AND INSTALLED BY OTHERS. PROVIDE ALL WIRING BETWEEN SENSOR AND EMS SYSTEM AS REQUIRED FOR A FULLY FUNCTIONAL CONTROL SYSTEM. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR AND EMS PROVIDER PRIOR TO ROUGH -IN. 4. PROVIDE ALLEN BRADLEY BOOT-ITZ ENCLOSURE WITH AN 800H-R2DI PUSHBUTTON AND 22/2 AWG WIRE FROM PUSHBUTTON TO THE MOOD HEAD EQUIPMENT LOCATED IN THE DATA ROOM. 5. PREWIRED/TERMINATED POWER POLE BY OTHERS. REFER TO D&P CUSTOM LIGHTS AND WIRING SYSTEMS DRAWINGS FOR DETAILS. PROVIDE 25' COIL FOR EACH CABLE AT THE TOP OF EACH POWER POLE UNLESS OTHERWISE NOTED. 6. INSTALL BOX 3'-0" INSIDE THE DOOR AT 14'-0" A.F.F. WITH 3/4" CONDUIT TO STRUCTURE. 7. MOUNT DISTRIBUTION BOX (FURNISHED BY OWNER) AT 12'-0" A.F.F. TO BOTTOM WITH MINIMUM 36" CLEAR ON THE RIGHT SIDE. GROUND BOX TO BUILDING STEEL. PROVIDE 4' X 4' X 3/4" UL LISTED PLYWOOD BACK BOARD. COORDINATE EXACT LOCATION WITH FLOOR & DECOR. 8. WIRELESS ACCESS POINT WIRING SHALL TERMINATE AT A SURFACE BOX. A 10' PATCH CORD SHALL BE PROVIDED TO CONNECT TO THE ACCESS POINT. 9. PROVIDE DATA CONNECTION TO SHOPPERTRACK. COORDINATE EXACT REQUIREMENTS WITH VENDOR PRIOR TO ROUGH -IN. REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC JAN 0 8 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 8'8 2017 PERMIT CENTER Tiglas 7 Engineering Associates, Inc Consulting Engineers Phone: 602.992.3900 Fax: 602.992.1541 809 W° Maryland Ave. Phoenh4 AL 85013 IamIe@tiglaseng.cem TEA #16201 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizono 85255 p: 480.515.5123 www.era360.com tij ill; .81 I V L 0 C. W Ca weNE Epwhi aimos co as -- - C 0 0 date: 8-10-201' issued for: PERMIT SUBMITTAL revision no.: date: 0 A A Job no.: 17-027 sheet title: FLOOR PLAN - DATA sheet no.: 05 FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX SYSTEM INPUTS I OPEN CIRCUIT 2 GROUND FAULT WIRE -TO -WIRE SHORT CIRCUIT SYSTEM AC POWER FAILURE SYSTEM LOW BATTERY SMOKE DETECTOR: OPEN AREA SMOKE DETECTOR: SMOKE/FIRE DOORS 8 SMOKE DETECTOR: DUCT -MOUNTED HEAT DETECTOR 10 MANUAL PULL STATION FIRE SPRINKLER FLOW SWITCH 12 FIRE SPRINKLER TAMPER SWITCH FIRE SPRINKLER POST INDICATOR VALVE SWITCH FIRE SPRINKLER PRESSURE MONITORING SYSTEM 15 FIRE PUMP POWER FAILURE 16 FIRE PUMP PHASE REVERSAL 17 FIRE PUMP RUNNING CONTROL UNIT ANNUCIATION REMOTE ANNUNCIATOR J�\` ��� � Jts," PR� � AG\p��`\PCOPO�� ����P�����pP CPP\-, �`�5��O �Ov ,� V LO O�� �,�Q- GJ�V �L\P P p� �J J� 5� ,,�f'- ,\O `tv? Pe PQ `� 0 _ O� O���P�PP P� P� G GO POOH P� P��P�PP` P� p� P P��P. •s° ����� O �P\� O� P[k P\ P �P� �\V \VOaP\ �P\.P IVF•V. P SPC - 4. ��O�p\ �P�P -\;,::::::: G� �P�' �1�' \C�P �\s..,;4,\ \ \F\c'P,- ,00, 0 \o�P \o�ro`�� �G5` \o eO`� y� \`�P \�o�o�� S\ \c� Q� \o ,\yo `�� �io �o� ry0 Q� 2� �� OJ J0 �Q PE` 2Q �Q OJ J0 �k' Q 4- `�p.i C� PP �5J `'Je CSO yti0 �P\ ,,,,re �J `'Je t�O iti0 \ Pp\�\��,<,.s„ v`,9B pft � I� ,c,:.9 ..4 JO\0�`�J�JO\0�\`�JP�\`�Q�PJO0�\`�JP�JO\0�`�JP�JO\0�`�J�\`�Q�PQ Q-_ Q-P�� G'JP GJP ,co P J J P J O P J P A• P J O P P SYSTEM OUTPUTS NOTIFICATION FIRE SAFETY C ABCDEF SYMBOL DESCRIPTION SYMBOL DESCRIPTION FACP GH Lam' I JK EVAC LMNOPQR 1=14 FIRE ALARM HORN, WALL MOUNTED FAA FIRE ALARM REMOTE ANNUNCIATOR Irl`® FIRE ALARM SPEAKER, WALL MOUNTED S T U V W AF AG AH �� IJV FIRE ALARM COMBINATION HORN AND STROBE, WALL MOUNTED TPR • • FIRE ALARM COMBINATION SPEAKER AND WALL MOUNTED FT FIRE ALARM CODED TRANSMITTER EK C • • FIRE ALARM DRILL KEY SWITCH [141C FIRE ALARM SPEAKER, CEILING MOUNTED 0 FIRE ALARM MANUAL PULLSTATION ):I( C FIRE ALARM STROBE, CEILING MOUNTED --(1) AUTOMATIC SMOKE DETECTOR, WALL MOUNTED E Z1 C ;IRE TROE GEIL O MOUNTION TED HORN AND AUTOMATIC SMOKE DETECTOR, CEILING MOUNTED C FIRE ALARM COMBINATION SPEAKER AND STROBE, CEILING MOUNTED (ODAUTOMATIC SMOKE DETECTOR DUCT MOUNTED, AND FIRE ALARM RELAY ((INTEGRAL OR FIELD -INSTALLED) • • RTS DUCT SMOKE DETECTOR REMOTE TEST SWITCH LNC IRE EARM HMNHORN ANDFTROBCIC OTE • • IAM FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE • AUTOMATIC HEAT DETECTOR, CEILING MOUNTED ZAM FIRE ALARM ZONE ADDRESSABLE MODULE _rn �/ BT AUTOMATIC SMOKE DETECTOR, BEAM TRANSMI I I t <, WALL MOUNTED MM FIRE ALARM MONITOR MODULE ®BT TRANSMI ITTGER, CE LING MOUTNOR�BEAM CM FIRE ALARM CONTROL MODULE _.(7) BB RREECEIVERIGL MK OD TEDGTOR, BEAM • • CO BR REEIVERG EVNG MO NTEDR, BEAM F FIRE SPRINKLER FLOW SWITCH �SA • • FIRE SPRINKLER TAMPER SWITCH AND CORROSION MONITORING SYSTEM SUPERVISORY CONNECTION ®SA AUTOMATIC SMOKE ALARM, CEILING MOUNTED • FIRE SPRINKLER ELECTRONICALLY SUPERVISED POST INDICATOR VALVE -(23)UV FLAME DETECTOR, ULTRAVIOLET TYPE i FIRE ALARM MAGNETIC DOOR HOLDER 42S)IR FLAME DETECTOR, INFRARED TYPE SI FIRE FIGHTER'S PHONE -QDVR FLAME DETECTOR, VISIBLE RADIATION TYPE • • HFSS HOOD FIRE SUPPIION SYSTEM n LJ HOOD FIRE SUPPRESSION SYST1ANUAL PULLSTATION 0 • 0 0 • • • • • • • • 0 • • • • • • • 0 • • • • • • • • • • Si • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 0 • • • • • • 0 • • • • • • • • • • • • • • • • • • • • 0 • • • • • • • • • • • • A BCDEF GH I JK LMNOP OR S T U V W X Y Z 2 3 4 5 6 7 8 9 10 II 12 13 14 15 16 17 FIRE ALARM SYMBOL LEGEND (SOME MAY NOT BE USED) SYMBOL DESCRIPTION SYMBOL DESCRIPTION FACP FIRE ALARM CONTROL PANEL. Lam' FIRE ALARM BELL EVAC FIRE ALARM VOICE EVACUATION PANEL 1=14 FIRE ALARM HORN, WALL MOUNTED FAA FIRE ALARM REMOTE ANNUNCIATOR Irl`® FIRE ALARM SPEAKER, WALL MOUNTED NAC FIRE ALARM NOTIFICATION APPLIANCE POWER SUPPLY ( FIRE ALARM STROBE, WALL MOUNTED FATC FIRE ALARM TERMINAL CABINET �� IJV FIRE ALARM COMBINATION HORN AND STROBE, WALL MOUNTED TPR FIRE ALARM TRANSPONDER EI� IJ'®ASTROBE, FIRE ALARM COMBINATION SPEAKER AND WALL MOUNTED FT FIRE ALARM CODED TRANSMITTER EK C FIRE ALARM HORN, CEILING MOUNTED DK FIRE ALARM DRILL KEY SWITCH [141C FIRE ALARM SPEAKER, CEILING MOUNTED F FIRE ALARM MANUAL PULLSTATION ):I( C FIRE ALARM STROBE, CEILING MOUNTED --(1) AUTOMATIC SMOKE DETECTOR, WALL MOUNTED E Z1 C ;IRE TROE GEIL O MOUNTION TED HORN AND AUTOMATIC SMOKE DETECTOR, CEILING MOUNTED C FIRE ALARM COMBINATION SPEAKER AND STROBE, CEILING MOUNTED (ODAUTOMATIC SMOKE DETECTOR DUCT MOUNTED, AND FIRE ALARM RELAY ((INTEGRAL OR FIELD -INSTALLED) FIRE A L INIIIATNREDHORN AND RTS DUCT SMOKE DETECTOR REMOTE TEST SWITCH LNC IRE EARM HMNHORN ANDFTROBCIC OTE -) AUTOMATIC HEAT DETECTOR, WALL MOUNTED IAM FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE 13) AUTOMATIC HEAT DETECTOR, CEILING MOUNTED ZAM FIRE ALARM ZONE ADDRESSABLE MODULE _rn �/ BT AUTOMATIC SMOKE DETECTOR, BEAM TRANSMI I I t <, WALL MOUNTED MM FIRE ALARM MONITOR MODULE ®BT TRANSMI ITTGER, CE LING MOUTNOR�BEAM CM FIRE ALARM CONTROL MODULE _.(7) BB RREECEIVERIGL MK OD TEDGTOR, BEAM EOL END OF LINE RESISTOR CO BR REEIVERG EVNG MO NTEDR, BEAM F FIRE SPRINKLER FLOW SWITCH �SA AUTOMATIC SMOKE ALARM, WALL MOUNTED F FIRE SPRINKLER TAMPER SWITCH AND CORROSION MONITORING SYSTEM SUPERVISORY CONNECTION ®SA AUTOMATIC SMOKE ALARM, CEILING MOUNTED PIV FIRE SPRINKLER ELECTRONICALLY SUPERVISED POST INDICATOR VALVE -(23)UV FLAME DETECTOR, ULTRAVIOLET TYPE i FIRE ALARM MAGNETIC DOOR HOLDER 42S)IR FLAME DETECTOR, INFRARED TYPE SI FIRE FIGHTER'S PHONE -QDVR FLAME DETECTOR, VISIBLE RADIATION TYPE LJ FIRE ALARM KEY REPOSITORY (KNOX BOX) HFSS HOOD FIRE SUPPIION SYSTEM n LJ HOOD FIRE SUPPRESSION SYST1ANUAL PULLSTATION G A NOTE I (DD F r� F F I I _ RTU -12 59; F s.4y NOTE 3 THRESHOLD \ I _J C 3 NOTE I (' DD ! i\� r. 1 fCD RTU -9 r� I I NOTE I LJMD RTU -8 i�11 r_ NOTE I ®D I LJ RTU -11 Lk e r-� —n NOTE I L J®D RTU -6 P EL_ \i/ \I/\ `,''/ �� I/ \I ' \/ \/ 1I 7\/\/\/' `\/./\/i /I I/A�/VI/AI/V 1/\,,\!/\1,./\1 T -- 1'N /i\/\/1\/ \/\/1\/I\/1 1/\/\/\f VI vI//\I/\I \/\%I\/\/ /I\/\/\%' !/ \I/ \I/ \I/ \ I / \/ \/ \ NA\/I\/\/ ▪ %\/\/\/ /AI/\I/\I/\; <N/\'/N/ %\/i I ifl)j /\/\/r\, / \I/ \/- \/ N \/i\ /1\ \ /\ /I\ /I\ /i\ /1 1/\VV'/\/_A /\/\/\/_AI \/.\7\/I\/ I\/\/\/\/ •/\AN/\V\I /\/\/V,/\, \/1\/\/'.\/ N /I\/\7\/1 /\'/\/\/- /\/\/\!/\1 V /\/\/\/ \/V/\/'\% /VI/\/\/\/\\ /N/\I/\1/\; \/N/\/Iv/ Niv/Iv/y/ /\/\/'\/ \%./IT%T\/ N/1\/IN/N/1 '/N/\/\/\ VA!'\!/\I/N /V';/\/\I/\I N/NA/\/\/ 1 /',/1\/\7 \7 \/\/1\ 1 \1/\/\/\ !/V'\ /_' /\I/VI/\I/ N /\/\/\/\I LAN '\/\ /\I/\r/\/\I /N'ANANANC N, LJr- i11 vi/\I /A!/VI'1JL.J7l \/\/\/\% \/ ./\%1\% \/\/\/\% \A/Ai/A/\ V\I'\/\/ /\,/V1/\1/A /.A/v/\/ \/1 /v/IA\ N/\/\7\7 /\/\I/\/A. V\1 \/\1/\1 /\/\/ / 1 v/v/y%Iv% \/ ,/v/Iv/', A/y/y �N \/\/\/\% \/ /\/\ 1 /\/N/\ / N/ / N/ ./ V� \/ \I/ . II NI/ \/ \I/ \I '\ /I\_/IA /iN 7 L;V - \ /IA /I r —1 _N /1A / (;7;11"0 t0 / V'/ VI/ \/ _ ' / \,,,,,,N J NOTE I/ \/ N \%\/\/\\ '\/1:/\/'\71 LJ® A/\/\/V/II /\I/\/N/N VVI,'N/NI/ \,I D \I/VI/\i/\I \/I\/\/';A, N/I.,/\7\/i RTU -5 , /\/\/\/, / N/N'V\,/\1 \A/v/N/\A NOTE I ®D r� —I 1-1 LJ RTU -10 O O L 1 T NOTE I LJ D LRTU-3rI \/\'/ \%;\/\/\ / \/ \/ \/ Ni \/,A/\/2\/1 /\'/\/ \/\ \/\/\/\/ /\/\/\V/\ \/\/\/\/'' /\/\/\/N \/\7\ /\ /I \/\/\/N/i / y/v/y/v1 v/\/v/'\/ • A/\1/\I \/\/\/\/ ▪ v'/v/\/ /\/\/\'/NI \/\/\/'\/I vv.L'v/\/N /NI/NI/V/\ PI I\I,/IA7V/I /\i'\I(�VI/\I /\l/\/V/\ N 7 , / 6\ / V/I\/\/V/ IN.' \j/ .!/\ /\/\/\I/ N/,/I\/\/1 NA /\/\/1 . / ,/i\/\ I I\/I\/1\/I\ I/V'\/A/N� /VI/\I/\/V' N/I),/\/\fI N/\/\/\/ /1 NA}1 / ; N/N/ a II/\/N / \/\II ,_IJ_I) \/i /i\/1\t1 N/\/IA/\/ N/\I/\!/\1 \i/\I/\✓\I \7 ,/I\/1\/i \/\7V/\%' /\;'\/\V\ /\i/\/\/N \/i,/I\/I\7 \/V/V/\/ /v \/\/_1 /y/VI/v/,N ,\71,7\ /N/r \/v/Iv/v/. cur, ii\ /i.\7\/,,,,, -,-T T:OD 0 1,.' ,L \/I,/'N % ,/ /\ '\%\/ VN'N/N' /v/y/v/y / ,/\l\ 1 \/\/v/Iv/ /A \/\!/\I /A/A/\I/ 1//\jI\/I \� Al/\VN \/ / AI/\/\/N \/I /\/v N/yiv/N/ \/\/\/\ S/\/\/i\% ri /vI/y/y/NI NOTE 1 __-- L J®D RTU -2 \ /I\ /1\ /\ /I \ \I/\!/\!/\; /N/1\/\/1 / \V \/ \/1v/v Cl/ \I/ VI/ \1 ,v/i\/iy/-v/ /\/\1/\!/N \/\/\/\/ I/\!/\1/\1/ \A\/I\/i\ \I/ \I/ \1/ /\/i\/\/ /\/ \I/ \I/\/ \ \%\/\/\% /\V\/\V\, N/i\/V /\/' / N/ AI/ \/I\/\/\/. /\I/\/N/\ \/i\/\/',\7 %N/\/V'/\ �l-i ! H /IVB'' �� I�/I\/1V/;A - 1 \/ \ \ / ,/ \/ L /1\ /1\ F ' \,/\/\i\ v/v/v/ i/\/1\/\% /\/\/\/\ \/iv/v/I\/- 1 \1/ A1/ \,/ V� 1-- /\ /\ /I\ / l\/\!/\_/\ 1/ \/ \/ \1/ \' \/1\/\/\/ \/\/V'/\ \/\/1\/.\7 \1/ \1/ `• / \ N/N/1\/N/ /N/\/N/\ 1\/\/\/'\/ 1 FIRE ALARM PLAN E104 SCALE: 1116" =1'-0" C NOTE I IL L J ®D RTU -7 Ei 11 N7 /\, \%i\/\%N/N/ r/ y,I- 77-17 -7 - /`-7r l_G c G�, y G` /V /1 ,V_ \V\/\/\.,IJC'N/N/\' i 1 `i7\/ ,/\/y/\/\% v/' Lel i� !/ N/\/\/\/N!\ 1 '.i\/t/\/\/\/\/N \/I / \/_ `/ \/`7'1'%\/ \/ '' \ \/ t.y /y LV 1,11 GA 'N /I 1 l\ \/\'/\/\I\/\✓N C n \/ _ \l\/\7\7\/ ,L1--/ ,—z) ` /-�.,Z_ / N A\ ' I _t_ \'\,/\%\%\/\L\ NOTE I r®D I. L_ %\ _: ,/"``_'iT I ,. 1N...L' ..-.d��- 4_.._C,L,/`- /J .1, /I y1/N/N/V'/\ i\_/ ` //I ,"77 / C.7'%TI /\A'N71A/1N/Nt ./N'(�,/\/N/_ \/\/\/N l I7 /\/\/ l v/\/ \/ \/N/\/\/1\/\/\/\%' / `/ LJ®TEI RTU -1 D II Q F: --4 C GENERAL NOTES: A. THE CONTRACTOR SHALL PROVIDE A FULLY ENGINEERED DESIGN OF THE FIRE DETECTION AND ALARM SYSTEM FROM A QUALIFIED FIRE DETECTION AND ALARM SYSTEM DESIGNER. ANY FIRE DETECTION AND ALARM INFORMATION INDICATED ON THE DRAWINGS IS STRICTLY FOR THE PURPOSE OF FILING FOR PERMIT AND ESTABLISHING A MINIMUM CRITERIA TO AID THE FIRE DETECTION AND ALARM SYSTEM DESIGNER IN THE DESIGN OF THE FULLY ENGINEERED FIRE DETECTION AND ALARM DRAWINGS. DESIGNER SHALL BE NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN OR REGISTERED FIRE PROTECTION ENGINEER, EMPLOYED BY FIRE ALARM CONTROL UNIT MANUFACTURER, CONTRACTOR, OR INSTALLER, WITH EXPERIENCE DESIGNING FIRE ALARM SYSTEMS IN THE JURISDICTIONAL AREA OF THE AUTHORITIES HAVING JURISDICTION. B. THE DESIGNER SHALL PRODUCE ALL REQUIRED DRAWINGS, CALCULATIONS, AND EQUIPMENT SPECIFICATIONS REQUIRED FOR JURISDICTIONAL APPROVAL AND SUBMIT ALL REQUIRED DOCUMENTS TO THE AUTHORITY HAVING JURISDICTION FOR APPROVAL. C. THE DESIGNER AND CONTRACTOR ARE RESPONSIBLE TO CLOSELY COORDINATE WITH THE FIRE SPRINKLER CONTRACTOR TO PROVIDE APPROPRIATE MONITORING OF ALL FLOW SWITCHES, TAMPER SWITCHES, PRESSURE SWITCHES, CORROSION MONITORING SYSTEMS, ETC. D. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MATERIALS, COMPONENTS, AND LABOR REQUIRED FOR A COMPLETE, OPERATIONAL, CODE -COMPLIANT FIRE DETECTION AND ALARM SYSTEM BASED ON THE FULLY ENGINEERED FIRE ALARM DRAWINGS THAT THE CONTRACTOR IS RESPONSIBLE TO PROVIDE. E. ALL NEW FIRE ALARM CONTROL PANELS THAT ARE INSTALLED WITHIN MULTI -OCCUPANCY BUILDINGS THAT ARE EQUIPPED WITH A MAIN BUILDING FIRE ALARM CONTROL PANEL SHALL BE INTERLOCKED WITH THE MAIN BUILDING FIRE ALARM CONTROL PANEL SUCH THAT ALL ALARM, SUPERVISORY, AND TROUBLE SIGNALS REPORTED AT THE TENANT'S FIRE ALARM CONTROL PANEL SHALL ALSO BE TRANSMITTED TO THE MAIN BUILDING FIRE ALARM CONTROL PANEL. F. PROVIDE FINAL CONNECTION FROM FIRE ALARM CONTROL PANEL TO ELECTRONICALLY SUPERVISED POST INDICATOR VALVE. COORDINATE EXACT LOCATION AND ALL REQUIREMENTS WITH FIRE SPRINKLER CONTRACTOR PRIOR TO ROUGH -IN. FIRE ALARM NOTES: I. DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL ALSO PROVIDE A REMOTE KEYED TEST STATION WITH VISUAL STATUS ANNUNCIATOR WHEN DUCT SMOKE DETECTOR IS INSTALLED IN A CONCEALED LOCATION GREATER THAN 10'-0" ABOVE FINISHED FLOOR OR WHEN DUCT SMOKE DETECTOR'S STATUS INDICATORS ARE NOT READILY VISIBLE. COORDINATE LOCATION OF REMOTE KEYED TEST STATION WITH AUTHORITY HAVING JURISDICTION AND OWNER PRIOR TO ROUGH -IN. DUCT SMOKE DETECTORS ASSOCIATED WITH HVAC UNITS THAT SHARE A COMMON AIR PLENUM SHALL BE INTERLOCKED WITH ONE ANOTHER SUCH THAT ACTIVATION OF ANY ONE OF THE ASSOCIATED DUCT SMOKE DETECTORS WILL SHUT DOWN SUPPLY FANS OF ALL HVAC UNITS SHARING THE COMMON AIR PLENUM. ALL FINAL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. 2. CONTRACTOR SHALL PROVIDE ROUGH -IN IN THE BASE BID. PROVIDE A UNIT PRICE ON THE BID FORM FOR THE COST TO PROVIDE THE NOTIFICATION APPLIANCE AND TO CONNECT IT TO THE FIRE ALARM SYSTEM. 3. PROVIDE EXTERIOR WEATHERPROOF NOTIFICATION APPLIANCE MOUNTED DIRECTLY ABOVE THE FIRE DEPARTMENT CONNECTION POINT. COORDINATE THE LOCATION OF THE FIRE DEPARTMENT CONNECTION POINT WITH THE FIRE SPRINKLER CONTRACTOR PRIOR TO ROUGH -IN. PROVIDE SILENT KNIGHT 5700 FIRE ALARM CONTROL PANEL. VERIFY SPECIFICATION WITH FLOOR AND DECOR. DUCT DETECT Cfia 2 cM HVAC UNIT SHUT DOWN REVIEWED FOR COMPLIANCE WITH TPA 70 - NEC JAN 08 2018 City of.Tukwrila` BUILDING DIVISION ROOF PROVIDE AUDIO DEVICES TO ACHIEVE A MINIMUM OF 70dlo OR IS db ABOVE ALL FIRE ALARM CONDUCTORS SHALL BE RUN /N E.M.T. (7-11:, OF ALL) ® AMBIENT NOISE IN AL.L. AREAS. PRCVIDE ADDITIONAL DEVICES AS REQUIRED (TYPICAL). CI CI 120V POWER FACP CONNECTION TO PA SysTEm TO DISABLE AMBIENT NOISE IN THE EVENT OF ALARM CONDITION GROUND LEVEL CDFIRE ALARM RISER DIAGRAM SCALE: NONE EL RECEIVED CITY OF TUKWILA DEC a8 2017 PERMIT CENTER Engineering Associates, inc Consulting Engineers Phone: 602.992.3900 Fax: 602.992.1541 809 W. Maryland Ave. Phoenix, Ai. 85013 TEA #16201 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 p: 4805155125 1004 CCCC Crl Cfl CI CD cyo C) 1141,1 Sow CD E lex WI hid mil I= vim CD az GO Rpm date: 8-10-201' issued for: PERMIT SUBMITTAL revision no.: dote: A Job no.: 17-021 sheet title: FLOOR PLAN - FIRE ALARM sheet no.: 0 4 L4-/5,/5,17 0 r- 28 r L4-28 28 28 EF 28 28 H/-/4 26 +48" AFF! L4-23 ®I L5 -30R ±L4-21 EF -2 0 L4-2 TRANSFORMER 7-L41 [1— SUSPEND FROM DECK MIN. 16' A.F.F. TO BOTTOM "42 5 +66' 5 3 rs 3 ENLARGED OFFICE POWER PLAN E401 SCALE: 1/4" =1'-0" NOTE /0 (TYPICAL) 2 ENLARGED OFFICE LIGHTING PLAN E401 SCALE: 114" =1'-0" 0 BOX S� NOTE 7 1y BOX ;4" (NOTE 4 COORDINATE EXA T LOCATION WITH c) FD r_ 2 NOTE / •QN]n l 'QND%N0TE3 1+60" V2D +60" — to — JQ 'o ISAFEI I II I VJ NOTE 2 NOTE 8 I I L J 3C ==D +60".^-1 1'd 13C 1 ENLARGED OFFICE TECHNOLOGY PLAN E401 SCALE: 1/4" =1'-0" REVIEWED FOR COMPLIANCE WITH NPPA70 - NEC JAN 0 8 2018 City of.Tukwila, BUILDING DIVISION KEYED NOTES: I. BACKBOARD PROVIDED BY OTHERS, REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. PROVIDE 3" CONDUIT WITH PULL STRING FROM 6-6" A.F.F. TO ABOVE CEILING FOR CABLING RACEWAY. 3. POWER, DATA LINE, AND EMPTY JUNCTION BOX WITH PULL STRING FOR FUTURE CABLE. 4. PROVIDE FIBER OPTIC TELEPHONE SERVICE TO THE IT ROOM. COORDINATE ALL REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. 5. PROVIDE FINAL CONNECTION TO FIRE ALARM AND SECURITY PANEL. COORDINATE ALL REQUIREMENTS WITH FIRE ALARM CONTRACTOR AND SECURITY VENDOR. 6. PROVIDE PLYWOOD BACKBOARD FOR IT ROOM PERIMETER. REFER TO ARCHITECTURAL DRAWINGS. 7. PROVIDE TWO 3" CONDUITS WITH GROMMETS AND PULL WIRE FROM BOX 'A" AND BOX "S" UP TO STRUCTURE. 8. SECURITY VENDOR WILL PROVIDE AND INSTALL A JUNCTION BOX WITH LOW VOLTAGE CONNECTIONS. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FOR CONNECTION BETWEEN THIS JUNCTION BOX AND THE EMS SYSTEM IN THE ELECTRICAL ROOM. COORDINATE ALL REQUIREMENTS WITH EMS AND SECURITY VENDORS. 9. PROVIDE FINAL CONNECTION TO HAND DRYER. COORDINATE MOUNTING HEIGHT WITH ARCHITECT AND ALL REQUIREMENTS WITH EQUIPMENT MANUFACTUR �R J E_ I V E u TO ROUGH -IN. CITY OF TUKWILA 10. CEILING AND WALL MOUNTED OCCUPANCY SENSORS SHALL BE PROVIDED BY GENERAL CONTRACTOR. DEC 0/8 2017 PERMIT CENTER m II aS Phone: 602.992.3900 Fax: 602.992.1541 809 W. Maryland Ave. Phoenix, AL 85013 Engineering ,amlemaseng.cam Associates, inc TEA#16201 Consulting Engineers SAKE REINDEREMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizona 85255 p: 480.515.5123 www.sra360.com C O V Prif1 WtiL CCM 00 V VD CD Q: GO r7 CD �I cn CD 141) vco c•rVD 1 g� 4 U O L C. 5 V 8 low date: 8-10-2017 issued for: PERMIT SUBMITTAL revision no.: date: A 6 job no.: 17-027 sheet title:ENLARGED POWER/LIGHTING PLANS sheet no.: E401 IN OUT Cl C2 C3 C4 G L N SCALE: NONE LCB -LX EMS CONTROLS CONTROLLER BOX BY OWNER 2 LCM EMS CONTROLS LIGHT CONTROL MODE BY OWNER 4 RIB2401D ENCLOSED PILOT RELAYS, FUNCTION DEVICE INC. BY OWNER 7 K4121C PHOTOCELL SENSOR - INTERMATIC BY OWNER 8 BURGLAR ALARM CUSTOMER SECURITY INTERFACE BY OWNER O DLC DIMMING LIGHT CONTROLLER BY OWNER I E 1 2 3 4 1 2 3 4 N N U D E T 0 0 0 0 0-0-0-0 Q000900000000 0 d o o 0 0 0 0 0 CB) o �l 0 0 H 0 0 0 0 U �-I-. 0 0 0 0 0 0 0 0 'N. 0 0 0 0 0 0 0 0 0 U 0 1-4. 0 0 0 -0 C 0 0 .moo • 1` 0 1-4. o H o l -k 0 0-1-I. 0 FL 0 0 'FL a 0 0 - I - ARM DISARM 0 1p 0 ALARM ACTIVATED WHT/BLK 120VAC C LINE BLU/WHT 24VAC/DC 0 WHT/YEL COMM NEUT BLU N/0— "1" /C0 N1C COMM ORY N/C0 0 BRN PRP N/0 COMM LIGHTING CONTROL RISER DIAGRAM 0 ONE CONTROLLER PER ZONE. Y3 RTN 0 RC Q Y1 Q W/O/B 0 GQ W2 0 Y2 Q CO Si 0 Si RTN 0 S2 Q S2 RTN 0 DC IN 0 DC OUT 0 Y3 Q TRANSFORMER 120V LOADS TO LIGHTING FIXTURES MANUFACTURED WIRING SYSTEM (MWS) TO FIXTURES WIRE TROUGH 0-10VDC LED INPUT MOTION, ALARM, PHOTOCELL REAR OF BUILDING 0 0 0000 LCM-1 0 0 0000 FROM LIGHTIIG CIRCUIT BREAKERS TO AUTOMATIC LIGHTING CONTROL CONTACTORS LCM-2 DEDICATED 120VAC L118 0 LCB -1 LCB -LX CONTACTOR BOX PANEL H1 0 FROM SITE LIGHTING CIRCUIT BREAKER TO AUTOMATIC LIGHTING CONTROL CONTACTORS PANEL L3 0 FROM EXHAUST FAN CIRCUIT BREAKER TO AUTOMATIC LIGHTING CONTROL CONTACTORS CONTROL WIRING .c.) TO FRONT SIGNAGE FRONT OF BUILDING 0 LCB -2 PANEL L2 0 1 EMS LIGHTING CONTROL E501 SCALE: NONE LIGHTING CONTROL SCHEDULE LCB -1 SALES FLOOR SALES FL(OR SALES FLOOR SALES FLOOR ZONE 1 ZONE 2 ZONE 3 ZONE 4 m— m--- ^.-NN N NCJC')M xx2x xxx2 xxxx xxxx SALES FLOOR ZONE 5 x xxx EXTEROR OFFICE CANOPY ZONE 6 LIGHTS ooww Twww xxParsU)U)U) CON1ACTOR BOX AT REAR OF BUILDING SIGNAGE SIGNAGE O TCT UUo N N N N J J J J m LOLO J U) V)V) CONTACTOR BOX AT FRONT OF BUILDING LCB -2 GALVANIZED 1° BOLT THREADED RODS GENERAL SHEET NOTES 1. THE EMS CONTROL SYSTEM IS TO BE PROVIDED BY OWNER. 2. CONTRACTOR TO INSTALL ALL PROVIDED HARDWARE. 3. CONTRACTOR TO PROVIDE 120V POWER TO THE EMS LIGHTING CONTROL PANEL. 4. CONTRACTOR TO INSTALL ALL LIGHTING WIRING FROM LIGHTING CONTROL PANEL TO THE EMS CONTACTOR PANEL AND FROM THE CONTACTOR PANEL TO THE LIGHTING LOAD. 5. CONTRACTOR IS RESPONSIBLE FOR ALL LOW VOLTAGE AND CONTROL WIRING REQUIRED TO COMPLETE THE EMS LIGHTING CONTROL SYSTEM. 6. CONTRACTOR IS RESPONSIBLE FOR THE INITIAL TESTING OF THE EMS SYSTEM. 7. EMS VENDOR WILL BE RESPONSIBLE FOR FINAL CONNECTIONS TO THE FLOOR AND DECOR'S NETWORK AND COMMISSIONING. 8. EMS VENDOR CONTACT INFORMATION: LAURA BARRINGTON, PHONE 1(800)820-3511 E-MAIL SUPPORT@entouchcontrols.com 1(877)755-1609 EMS LIGHTING CONTROLS LIGHTING CONTROL OPERATIONAL DESCRIPTION: 1. THERE WILL BE FOUR (4) INTERIOR AUTO STORE MODES OF CONTROL. THE FOUR (4) AUTO MODES OF CONTROL ARE OFF, STOCKING, SALES AND SECURITY. THREE (3) OF THE MODES ARE ACTIVATED BY THE TIMING FUNCTION OF THE EMS SYSTEM AND THE SECURITY MODE FUNCTION IS ACTIVATED BY THE BURGLAR ALARM VIA THE EMS SYSTEM. A DESCRIPTION OF THE FOUR (4) MODES ARE AS FOLLOWS: A) OFF MODE: ALL LIGHTING IN THE ENTIRE INTERIOR OF THE STORE IS TURNED OFF WITH THE EXCEPTION OF THE EXIT LIGHTS AND DIRECTIONAL EXIT LIGHTS. B) STOCKING MODE: THE DIMMING SYSTEM IS AT 50%. STAGE 1 SALES FLOOR LIGHTING ONE NIGHT LIGHT AND 2 SALES FLOOR LIGHTING THE NEXT TO EVEN THE LAMP DEPRECIATION, THE OCCUPANCY SENSORS IN THE OFFICE PACKAGE ARE ENABLED I.E. THE LIGHTS IN INDIVIDUAL ROOMS WILL GO ON AND OFF AS PEOPLE ARE SENSED OR NOT SENSED, STOCKING MODE IS ACTIVATED AND OVERRIDES THE OFF MODE WHEN THE MANAGEMENT TEAM PUTS THE BURGLAR ALARM IN THE PERIMETER MODE. C) SALES MODE THE DIMMING SYSTEM IS AT 100% AND THE OCCUPANCY SENSORS ARE ENABLED. ACTIVATED BY TIME CLOCK FUNCTION INTEGRAL TO THE EMS SYSTEM. D) SECURITY MODE: WHEN THE BURGLAR ALARM IS IN FULL ALARM ALL OF THE FIXTURES ON THE INTERIOR WILL BE TURNED ON. 2. THE EXTERIOR LIGHTS WILL BE CONTROLLED BY THE ASTRONOMIC TIME CLOCK FUNCTION INTEGRAL TO THE EMS SYSTEM SYSTEM AND PHOTO CELL, THE EXTERIOR LIGHTING WILL BE TURNED ON AT DUSK AND TURNED OFF AT DAWN. 3. THE STORE SIGNAGE IS TO BE INDEPENDENTLY CONTROLLED BY THE ASTRONOMIC TIME CLOCK FUNCTION INTEGRAL TO THE EMS SYSTEM AND PHOTO CELL. SIGNAGE IS TURNED ON AT OPENING AND TURNED OFF AT CLOSURE UNLESS OVERRIDDEN BY SEASONAL CONSIDERATIONS. 4. SITE POLE SECURITY LIGHTING TO BE CONTROLLED BY THE PHOTO CELL. THE LIGHTING WILL BE TURNED ON AT DUSK AND OFF AT DAWN. ITEM® PART # DESCRIPTION 1 LCB -LX EMS CONTROLS CONTROLLER BOX BY OWNER 2 LCM EMS CONTROLS LIGHT CONTROL MODE BY OWNER 4 RIB2401D ENCLOSED PILOT RELAYS, FUNCTION DEVICE INC. BY OWNER 7 K4121C PHOTOCELL SENSOR - INTERMATIC BY OWNER 8 BURGLAR ALARM CUSTOMER SECURITY INTERFACE BY OWNER O DLC DIMMING LIGHT CONTROLLER BY OWNER 1 1/2" X 1-1/2° CHANNEL OR STRUG GALVANIZED DOUBLE NUT WITH WASHERS 2 CONDUIT SUPPORT DETAIL E501 SCALE: NONE REVIEWED FOR - MPLUANCE WITH NPPA70 o NEC JAN 08 2010 City of of .Tukwila BUILDING DIVISION RECEIVED, Ci TY OF TUKWIL/. DEC O 8 2017 PERMIT CENTER Was Engineering Associates, inc Consultlng Engineers Phone: 802.992.8900 Fax: 802.992.1541 809 W. MaMon d Ave. Phoenix, AL 85018 la®Ie©tlglaseng.com TEA #16201 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizona 85255 p: 480.515.5123 www.sra360.com PLIP1 tag 00 V CD N ' m,n C) CD cs (1)c0 � W. fel 4.t V8 V a) O L a W CD low es CA upma ma Rio ca wet cod cos tea mew pm*l i1• 0. date: 8-10-2017 issued for: PERMIT SUBMITTAL revision no.: date: A A A A job no. : 17-027 sheet titlEMS DIAGRAM DETAILS AND SCHEDULES sheet no.: E501 PANEL LABEL MSB L2 VOLTAGE PHASE WIRE VOLTAGE PHASE WIRE 480/277 208/120 A MAIN CIRCUIT BREAKER I MAIN LUGS ONLY I SUB FEED LUGS FEED THROUGH LUGS ASSEMBLY PROVIDED MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS 800 I SURFACE PANEL MOUNTING BUS AMP RATING— 800 3 3 225 PANEL LOCATION— SEE PLAN PANEL LOCATION— SEE PLAN 4 I I 'PANEL NEUTRAL BUS MINIMUM AIC RATING 65,000 GROUND BUS ELECTRIC POWERWALL 10,000 BY F&D YES VOLTAGE 480 VOLTAGE 480 SCHNEIDER 208 CIRCUIT DESCRIPTION LOAD (KVA) BREAKER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMP POLE AMP POLE A B I C RTU -\(LARGEST MOTOR AT 125%) 11634 B I C `: 45 3 1 A 2 45 3 10117 2 RTU -2 1 540 11634 : RECEIVING DESK 3 B 4 373 20 "+ 10117 10117 B 4 20 1 11634 360 DOCK LIGHTS 5 C 6 528 20 1 10117 C RTU -3 10117 1 ': 45 3 7 A B 45 3 - RTU -4 7 A 10117 20 1 9 B 10 SPARE I , 10117 10117 20 1 9 10117 10 20 11 C 12 SPARE SPARE 12 10117 SPARE RTU -5 10117 11 : 45 3 13 A 14 45 3 : RTU -6 LIGHTING SALES FLOOR 20 10117 13 A 15 0 16 20 1 - 10117 10117 SPARE LIGHTING SALES FLOOR 1260 10117 1 15 17 C 18 20 1 1 10117 SPARE RTU -7 10117 ` 45 3 19 A 20 45 3 20 RTU -8 BUSSED SPACE SPARE 10117 4679 : 21 B 22 A 20 1 10117 1 '.. BUSSED SPACE 10117 " 4658 23 C 24 1 21 B " 10117 23 RTU -9 10117 BUSSED SPACE 45 3 25 A 26 30 3 6263 24 RTU -10 SPARE LIGHTING SALES FLOOR 10117 BUSSED SPACE 20 27 B 28 28 20 '. 6263 1620 SPARE BUSSED SPACE A PHASE B PHASE C PHASE TOTAL KVA 10117 20 TOTAL KVA 4.6 29 C 30 TOTAL AMPS 12.7 1 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION 6263 SPARE RTU -11 6263 'r 30 3 31 A 32 30 3 6263 `. RTU -12 : 4399 6263 1 33 33 B 34 180 20 8310 6263 TRACK LIGHTING DISPLAY 34 1731 6263 1 35 35 C 36 20 8310 ': 6263 TRACK LIGHTING DISPLAY RTU -13 4095 20 20 3 37 A 38 30 3 8310 FORKLIFT CHARGER SPD 38 20 4095 1 39 B 39 B 40 : 8310 39 SPARE 40 20 20 4095 41 C 41 C 42 8310 41 TOTALS 18083 119700 XFMR TLI (PANELS L1/L3) 11058 15680 45 3 43 A 44 70 3 8747 41583 41698 39801 123082 XFMR TL4 (PANELS L4/L2) TOTAL AMPS 148.0 A PHASE B PHASE C PHASE TOTAL KVA 12030 TOTAL KVA 28.7 8747 11913 8038 28698 45 B 46 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION : 11913 9380 47 C 48 :: 8038 BUSSED SPACE 49 A 50 800 3 ': GENERATOR INPUT C/B BUSSED SPACE 51 B 52 BUSSED SPACE 53 C 54 PANEL HI 41583 200 3 55 A 58 BUSSED SPACE 41698 57 B 58 BUSSED SPACE 39801 59 C 60 BUSSED SPACE TOTALS 115101 1116188 111621 61741 64907 61032 A PHASE B PHASE C PHASE TOTAL KVA TOTAL KVA 530.6 176842 181095 172653 530590 TOTAL AMPS 638.2 PANEL LABEL BUS AMP RATING— PANEL LOCATION— MINIMUM AIC RATING VOLTAGE L2 VOLTAGE PHASE \VIRE VOLTAGE PHASE WIRE 480/277 208/120 A I MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS I SURFACE PANEL MOUNTING SURFACE PANEL MOUNTING 60 3 225 PANEL LOCATION— SEE PLAN 60 SEE PLAN 4 FULL PANEL NEUTRAL BUS MINIMUM AIC RATING 25,000 FULL PANEL NEUTRAL BUS 10,000 GROUND BUS VOLTAGE 480 YES VOLTAGE 208 208 CIRCUIT DESCRIPTION LOAD (KVA) CIRCUIT DESCRIPTION CKT LOAD (KVA) BREAKER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMP POLE AMP POLE A B I C SPARE 20 1 1 : :. : 20 1 1 A 2 20 1 540 SPARE : RECEIVING DESK TELEPHONE BOARD 3 B 373 20 1 3 B 4 20 1 3134 360 DOCK LIGHTS UNIT HEATER UH -1 C 6 528 20 1 5 C 6 20 1 20 1620 QC J -BOX _ SUMP PUMP P-1 8 1187 1 : 20 1 7 A 8 20 1 9 : SPARE SPARE I 10 1498 20 1 9 B 10 20 1 C 12 SPARE SPARE 12 20 SPARE 20 1 11 C 12 20 1 14 20 SPARE SPARE : WATER HEATER WH -1 LIGHTING SALES FLOOR 20 1 13 A 14 B 18 20 1 BUSSED SPACE SPARE SPARE LIGHTING SALES FLOOR 1260 20 1 15 B 16 18 20 1 1 BUSSED SPACE SPARE LIGHTING SALES FLOOR 3201 %. - 20 1 17 C 18 20 1 20 i BUSSED SPACE SPARE 20 4679 : 20 1 19 A 20 1 20 1 '.. BUSSED SPACE SPARE " 4658 20 1 20 1 21 B 22 1 23 LIGHTING SALES FLOOR BUSSED SPACE SPARE 20 1 25 20 1 23 C 24 -: SPARE LIGHTING SALES FLOOR 1 BUSSED SPACE 20 TOTALS 1167 1373 528 28 20 1 540 380 1620 SPARE BUSSED SPACE A PHASE B PHASE C PHASE TOTAL KVA 2494 20 TOTAL KVA 4.6 1707 733 2148 4588 30 TOTAL AMPS 12.7 1 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS PANEL LABEL H1 issued for: PERMIT SUBMITTAL VOLTAGE PHASE \VIRE A 480/277 A I MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS I SURFACE PANEL MOUNTING BUS AMP RATING— 225 3 225 PANEL LOCATION— SEE PLAN 4 4 I I FULL PANEL NEUTRAL BUS MINIMUM AIC RATING 25,000 GROUND BUS GROUND BUS I (ES VOLTAGE 480 VOLTAGE 208 CIRCUIT DESCRIPTION LOAD (KVA) 3REAKER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMP POLE AMP POLE A 0 I C EXTERIOR LIGHTS 470 VENDING 1000 20 1 1 A 2 30 3 3880 180 : COMPACTOR EXTERIOR LIGHTS SPARE 450 20 1 3 B 4 4 20 : 3860 750 EXTERIOR LIGHTS ' 3134 20 1 5 C 6 C 6 20 1 1 LIGHTING SALES FLOOR 2660 : 20 1 7 A 8 20 1 8 ' SPARE LIGHTING SALES FLOOR `: 3858 20 1 9 B 10 20 I 10 1498 OFFICE LIGHTING LIGHTING SALES FLOOR :' 3491 20 1 11 C 12 20 1 12 20 SPARE LIGHTING SALES FLOOR 4323 : - 20 1 13 A 14 20 1 3000 : WATER HEATER WH -1 LIGHTING SALES FLOOR ': 4188 20 1 15 B 18 20 1 15 B SPARE LIGHTING SALES FLOOR 1260 3793 20 1 17 C 18 20 1 1 17 SPARE LIGHTING SALES FLOOR 3201 %. - 20 1 19 A 20 20 1 20 i SPARE LIGHTING SALES FLOOR 20 4679 20 1 21 B 22 20 1 20 1 21 SPARE LIGHTING SALES FLOOR " 4658 20 1 23 C 24 20 1 1 23 SPARE LIGHTING SALES FLOOR 2709 "_. 20 1 25 A 26 20 1 25 -: SPARE LIGHTING SALES FLOOR 1 2328 20 1 27 B 28 20 1 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION B SPARE LIGHTING SALES FLOOR 2 2494 20 1 29 C 30 20 1 I 8310 C SPARE LIGHTING SALES FLOOR 3335 I' 20 1 31 A 32 30 3 '. FORKLIFT CHARGER LIGHTING STOCK ROOM : 4399 20 1 33 B 34 ' 180 20 8310 33 TRACK LIGHTING DISPLAY 34 1731 20 1 35 C 36 20 8310 1 35 TRACK LIGHTING DISPLAY 1385 - -_-. 20 1 37 A 38 30 3 60 8310 FORKLIFT CHARGER SPARE 38 20 20 1 39 B 40 7678 3690 : 8310 39 SPARE 40 20 20 1 41 C 42 16350 2090 4460 8310 41 TOTALS 18083 119700 19301 1 15680 4900 23500 21998 20500 5867 17293 A PHASE B PHASE C PHASE TOTAL KVA TOTAL KVA 32.4 11058 12030 9360 32448 TOTAL KVA 123.1 41583 41698 39801 123082 2540 TOTAL AMPS 148.0 A PHASE B PHASE C PHASE TOTAL KVA GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, FPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION GFCI PANEL LABEL L3 issued for: PERMIT SUBMITTAL VOLTAGE PHASE WIRE A 208/120 A MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS 150 SURFACE PANEL MOUNTING BUS AMP RATING— 60 3 60 PANEL LOCATION— SEE PLAN 4 FULL PANEL NEUTRAL BUS MINIMUM AIC RATING 10,000 GROUND BUS YES VOLTAGE 208 CIRCUIT DESCRIPTION LOAD (KVA) BREWER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMF POLE AMP POLE A B I C VENDING 1000 20 1 1 A 2 20 1 180 : RECEPT. COFFEE MACHINE SPARE 1500 1080 20 1 3 B 4 20 1 1 750 1080 AUTO DOOR ICE MAKER '. 600 20 1 5 C 6 20 1 1 750 AUTO DOOR UNIT HEATER UH -2 528 540 20 20 1 7 A 8 20 1 1000 : ' VENDING SECURITY PEDESTAL : 380 20 1 9 B 10 20 1 1060 QCJ-BOX QCJ-BOX SPARE 540 20 1 11 C 12 20 1 1 200 PUBLIC VIEW MONITOR HEAT TRACE - ROOF HYDRANT 500 2160 ; 20 1 13 A 14 20 1 1080 % < QCJ-BOX BUSSED SPACE SPARE 200 20 20 1 15 B 18 1 1260 1200 SIGN BUSSED SPACE SPARE 750 20 1 20 1 17 C 18 180 1200 SIGN AUTO DOOR 750 BUSSED SPACE SPARE 20 1 20 1 19 A 20 180 RECEPTS - DATA RACK RECEPT. '.` r BUSSED SPACE SPARE 20 1 20 1 21 B 22 DRYER-WOMENS 1200 - SIGN BUSSED SPACE SPARE 540 20 20 1 23 C 24 1 ' 1620 QCJ-BOX BUSSED SPACE TOTALS 2028 11860 1140 1 25 A 1180 11830 950 1 A PHASE B PHASE C PHASE TOTAL KVA -- : EMS TOTAL KVA 9.0 3208 3890 2090 8988 540 TOTAL AMPS 24.9 1 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION GFCI EMS EMS EMS HLO HPL GFCI HLO HLO HLO HLO PANEL LABEL L1 issued for: PERMIT SUBMITTAL VOLTAGE PHASE WIRE A 208/120 A MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS 150 SURFACE PANEL MOUNTING BUS AMP RATING— 150 3 I I PANEL LOCATION— SEE PLAN 4 FULL PANEL NEUTRAL BUS MINIMUM AIC RATING 10,000 GROUND BUS YES VOLTAGE 208 CIRCUIT DESCRIPTION LOAD (KVA) BREAKER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMP POLE AMP POLE A B i C EF -1 300 20 20 1 1 A 2 20 2 12001. ' ' SIGN SPARE 1080 20 1 3 B 4 4 20 1 1200 1080 QCJ-BOX QCJ-BOX 600 540 20 1 5 C 6 20 1 360 QUAD RECEPT. QCJ-BOX 540 20 20 1 7 A 8 20 1 720 °. SECURITY PEDESTAL SIGN : 1200 20 1 9 B 10 20 1 1080 DVR RECEPT - VAULT QCJ-BOX SPARE 750 20 20 1 11 C 12 20 1 200 720 QUAD RECEPT. QCJ-BOX 2160 : 20 1 13 A 14 20 1 1080 % < QCJ-BOX PUBLIC VIEW MONITOR 900 200 20 1 15 B 16 20 1 1260 1200 SIGN AUTO DOOR 1000 750 20 1 17 C 18 20 1 180 1200 SIGN AUTO DOOR 750 20 - 20 1 19 A 20 20 1 180 RECEPTS - DATA RACK RECEPT. REGISTER J -BOX : 540 20 1 21 B 22 20 1 DRYER-WOMENS 1200 - SIGN REGISTERJ-BOX 1 540 20 1 23 C 24 20 1 ' 1620 QCJ-BOX REGISTER J -BOX 540 25 20 1 25 A 26 20 1 200 -- : EMS REGISTER J -BOX C 540 20 1 27 B 28 15 2 RECEPTS/EF-WORKROOM 1000 EWH-1 SIGN :; 540 20 1 29 C 30 1 1000 SPARE RECEPT-IRRIGATION CONTROL 180 : 20 1 31 A 32 20 1 '-SPARE ' SPARE RECEPT-CREDIT KIOSK ' 180 20 1 33 B 34 20 1 SPARE SPARE SPARE SPARE 20 20 1 35 C 36 20 1 SPARE SPARE SUBFEED- PANEL L3 3208 60 60 3 37 A 38 20 1 : SPARE 7678 3690 39 B 40 20 1 3380 SPARE TOTALS 16350 2090 4460 41 C 42 30 1 15680 4900 SPARE A PHASE B PHASE C PHASE TOTAL KVA 5867 17293 5498 TOTAL KVA 32.4 11058 12030 9360 32448 TOTAL AMPS 90.1 2540 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION PANEL LABEL L4 issued for: PERMIT SUBMITTAL VOLTAGE PHASE WIRE A 208/120 A MAIN CIRCUIT BREAKER MAIN LUGS ONLY SUB FEED LUGS FEED THROUGH LUGS 150 SURFACE PANEL MOUNTING BUS AMP RATING— 150 3 job no.: 17-027 PANEL LOCATION— SEE PLAN 4 FULL PANEL NEUTRAL BUS MINIMUM AIC RATING 10,000 GROUND BUS YES VOLTAGE 208 CIRCUIT DESCRIPTION LOAD (KVA) BREAKER CKT PH CKT BREAKER LOAD (KVA) CIRCUIT DESCRIPTION A B I C AMP POLE AMP POLE A B I C SECURITY PANEL 200 20 1 1 A 2 20 1 1360 ' ' RECEPT. - TRAINING/ CEM RECEPT.-CASH/TRAIN/CEM 1080 20 1 3 B 4 20 1 1080 QCJ-BOX TELEVISION - BREAK ROOM 600 20 1 5 C 8 20 1 1820 QCJ-BOX MICROWAVE - BREAK ROOM 1500 : 20 1 7 A 8 20 1 360 ' °. VAULT RECEPT. MICROWAVE - BREAK ROOM : 1500 20 1 9 B 10 20 1 180 DVR RECEPT - VAULT REFRIGERATOR - BREAK ROOM 750 20 1 11 C 12 20 1 200 FACP HAND DRYER - MENS 1200 : 20 1 13 A 14 20 1 1000 VENDING - BREAK ROOM TELEVISION - BREAK ROOM '. 900 20 1 15 B 16 20 1 1260 RECEPT.-CEM/ASSIST./BREAK ROOM VENDING - BREAK ROOM 1000 20 1 17 C 18 20 1 180 VAULT RECEPT. PORTABLE AC PAC -1 1280 20 1 19 A 20 20 1 600 :HAND EWC- CORR. 1 RECEPTS - DATA RACK 2880 30 1 21 B 22 20 1 1200 DRYER-WOMENS RECEPTS - DATA RACK - 1000 20 1 23 C 24 20 1 '- 540 RECEPT. - CORR. 2/ BREAK ROOM SPARE : 20 1 25 A 26 20 1 720 ` RECEPTS - RR'S/ JAN. / DATA CCTV-CASH/VAULT : 200 20 1 27 B 28 20 1 900 RECEPTS/EF-WORKROOM SPARE 20 1 29 C 30 20 1 SPARE SPARE :. 20 1 31 A 32 20 1 '-SPARE SPARE 20 1 33 B 34 20 1 SPARE SPARE 20 1 35 C 36 20 1 SPARE SUBFEED - PANEL L2 1707 60 3 37 A 38 20 1 -: SPARE 733 39 B 40 20 1 SPARE 2148 41 C 42 20 1 SPARE TOTALS 5867 17293 5498 2880 14620 2540 A PHASE B PHASE C PHASE TOTAL KVA TOTAL KVA 28.7 8747 11913 8038 28698 TOTAL AMPS 79.7 GFCI = GFCI CIRCUIT BREAKER, HLO= HANDLE LOCK ON DEVICE, HPL PERMANENTLY INSTALLEDHANDLE PADLOCK ATTACHMENT TO LOCK BREAKER IN OPEN POSITION EMS EMS EMS HLO HLO HLO GFCI HLO GFCI HPL REVIEWED FOR COMPLIANCE WITH NEPA70 - NEC JAN 0 8 2010 City of Tukwila BUILDING DIVISION! RECEIVED CITY OF TUKWILA. DEC 68 2017 PERMIT CENTER Tiglas Engineering Associates, inc Consulting Engineers Phone: 602.992.3900 Fax: 002992.1541 009 W. Maryland Ave. Phoenix, Al. 65013 lamle@Uglaseng.com TEA #16201 SAKE REINDERSMA ARCHITECT 5450 e. high street suite: 200 phoenix, arizona 85255 p: 480.515.5123 www.sra360.com els 4✓ 0 03 4✓ 0 V N N V 8 4-0 U 03 -I C L 0. date: 8-10-2017 issued for: PERMIT SUBMITTAL revision no.: date: A A A A job no.: 17-027 sheet title: PANEL SCHEDULES sheet no.: E 6 01