HomeMy WebLinkAboutPermit EL17-1058 - MATERO RESIDENCE - SOLAR PANELSMATERO RESIDENCE
12222 42 AVE S
ELI 7-1058
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL PERMIT
0179000040 Permit Number: EL17-1058
12222 42ND AVE 5
MATERO RESIDENCE
Issue Date: 2/1/2018
Permit Expires On: 7/31/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
MATERO ROCCO FRANK
12222 42ND AVE S , SEATTLE, ID,
98168
JEREMY HAMPSCH
418 E LAKESIDE AVE - SUITE 208 ,
COUER D'ALENE, ID, 83814
OFFSET SOLAR LLC (ELECTRICAL)
933 LOUISE AVE - SUITE 101E ,
CHARLOTTE, NC, 28204
OFFSESL833PE
Phone: (208) 640-9691
Phone: (877) 633-7385
Expiration Date: 10/16/2019
DESCRIPTION OF WORK:
ROOF MOUNT SOLAR ENERGY SYSTEM
Valuation of single family: $48,675.00
Valuation of mf/comm: $0.00
Type of Work: SERV CHNG
Fees Collected: $111.87
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Permit Center Authorized Signature:Va
I/
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: Date:
Print Name: (/��Gi��•/ l-rs J��`�'L
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS***
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC and the Washington Cities Electrical Code.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKWJLA
Community Development Department
Perinit Center
6300 Southeenter Bird,, Suite 100
Tukwila, W4 98188
http://www,TukwilaWA,gov
SITE LOCATION
Electrical Permit No. 'LI -17, 1056
Project No,
Date Application Accepted: 1)--)-q-i
Date Application Expires: tp
(For ttffice use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review,
Applications will not be accepted through the mail or by fax.
**Please Print**
Site Address: / .
Tenant Name: J2977th4.
King Co Assessor's Tax No.: 0/7 eiDocioqO
Suite Number: Floor:
New Tenant: D Yes ..No
PROPERTY OWNER
Name:
0 ez 104:i 1-0
Address: /2222 624-1 Ave. .5 oaci-
"itY:7; kt)47/4. State: WA Zip:Chlta8y
CONTACT PERSON — person receiving all project
cornmunication
Name: .t. 4., 4. e_ Z z --Te
1 ilet-irla: L
Address: zi 1 s, ,E.- 2..,/e,"
Phone: 26*._&144_114-/ Fax:
Contr Reg No.:01_cses,1 533feExp Date:4)/16bl.
CilY:6;,,e1,4-c" d :14lis-ilt.
,
State: -/Car,
Zip: 7
Phone: ....I
Fax:
Email: 'I, e,e1,11,4
Lz,—..it,,,,
ELECTRICAL CONTRACTOR INFORMATION
Company Name: oil,e,1 i-4,14,— 41_6
Address; iii g E La joe 5, 1.e. /1- ke . .5 j --.e. og
! City6etcr_ei,A64,14_ State: ..z.d. Zip: 833:41
Phone: 26*._&144_114-/ Fax:
Contr Reg No.:01_cses,1 533feExp Date:4)/16bl.
Tukwila Business License No,:
Valuation of Project (contractor's hid price): S /,75'
;2
Scope of Work (please provide detailed information): / Jept //'
Will service be altered'? EJ Yes Adding more than 50 amps? 0 Yes No
Type of -Use:
Type of work:
0 'New E] Addition 0 Service Change 0 Remodel 0 Tenant Improvement
0 Low Voltage Ej Generator Fire Alarm 0 Telecom mun iC3ti011 0 Temporary Service
Property Served bv:
Z, Puget Sound Energy 0 Seattle City Light
W:Trxm4,:e.mtrAppiscation$41a,f1±AmTerrn PtTfr
14tu,ary Z017
11,11
Palle / of 2
RESIDENTIAL
NEW RESTD.ENTIAL SERVICE
o New single family dwellings S155 91
(including an attached garage)
O Garages, pools, spas and outbw1dngs S83,54ea
17 Low voltage systems
(alarm, furnace thermostat) ... „ .. S6 .05 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
O Service change or alteration S8154
(no added/a(tered circuits)
al Service change with added/altered circuits c83 54
number of added circuits
S12.00 ca
o Circuits added/altered without service change $55,69
(up to 5 circuits)
O Circuits added/altered without service change
(6 or more circuits) . -$7.65 ea
o MeterImast repair S69 62
O Low voltage systems 561,05
(alarm, furnace thermostat)
MULTI -FAMILY
AND COMMERCIAL
Fees are based on the valuation
of the electrical contract,
MISCELLANEOUS FEES
O Temporary service Iresidential) 566.30
O Temporary service (generator) $82.52
O Manufacturcdimobile home service ...587.98
(excluding garage or outbui(ding)
D Carnivals .582 .21
Nullifier of concessions „ , 511.02 ea
Each ride and generator truck . , S11.02 ea
***EFFECTIVE JANUARY 1, 2014 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE***
PERMIT APPLICATION NOTES
Value of Construction - in all cases, a value of eonsauction amount should be entered by the applicant. This figure will be reviewed and is subject.
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date ofapplicatiori shall expire by limitation,
The Building Official may grant one extension of time for an additional period not to exceed 90 days, The extension shall be requested in writing
and justifiable cause demonstrated,
IHEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION ANE) KNOW THE SAME TO BE 'TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR 'ails PERMIT,
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: ("Ji 953 Day Telephone:
\t"
Mailing Address,Lfl' E LAV 24 4/ j5 3 zL
Sac z,p
Date:12-2/
Appfla.10,1154ian&A=PCM31 Arp,U=10TthnkrtlikVI7X,ii Prrrot Rtviltd
lapwry207
Page 2 nf 2
Cash Register Receipt
City of Tukwila
R13122
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$111.87
EL17-1058 Address: 12222 42ND AVE S
Apn: 0179000040
$111.87
Credit Card Fee
$3.26
Credit Card Fee
R000.369.908.00.00
0.00
$3.26
ELECTRICAL
$104.43
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$83.54
PLAN CHECK FEE
R000.345.832.00.00
0.00
$20.89
TECHNOLOGY FEE
$4:18
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R13122
R000.322.900.04.00 0.00
µ
$4.18
$111.87
Date Paid: Friday, December 29, 2017
Paid By: JEREMY HAMPSCH
Pay Method: CREDIT CARD 021607
Printed: Friday, December 29, 2017 11:24 AM 1 of 1
SYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PE MIT ND.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:1 , 9,'//
L�
,�
dv.
..//
Type of Inspection:
/`
Address: 2�
4/
Ali-.
Oate Called:
Special Instructions:
17V
Date Wanted:
c
� P.m.
Requester:
Phone No:
7.3'12
E6Approved per applicable codes.
LJ Corrections required prior to approval.
COMMENTS:
o K ("4-1
Inspector:
Date: 02/?
fS
REINSPECTION FEE REQUIRED. Prior to next inspection, fee muss be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
REVISIONS
rand
changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
: Revisions will require a new plan submittal
may include additional plan review fees
FILE COPY
Permit No. 0E0
Plan review epproval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approvod Field Copy and conditi is acknowledged:
By: _/
Date:
z-'/! /is
City of Tukwila
BUILDING DIVISION
ELL1 1058
'SEPARATE PERMIT
REQUIRED FOR:
t u�lechanical
Electrical
ls�"PIumbing
Q6G{as Piping
City of Tukwila
131i`►--i''JG DIVISION
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
JAN p 8 2018
LI
w
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 292017
PERMIT CENTER
REVIEWED FOR
COMPLIANCE
OCNEC
JAN 0 8 2018
City of Tukwila
BUILDING DIVISION_
RECEIVED
CITY OF TUKWILA
DEC 2 9 2017
PERMIT CENTER
Site Assessment
Customer: Rocco Matero
Address: 12222 42nd Ave S, Tukwila: WA 98168, USA
Phcne:
System size:8,85 kW
System cost:44,250
Date: November 29th, 2017.
1 c,2ft
171ft
6ft
REVIEWED .FOR
COMPLIANCE WITH
NFPA 70 - NEC
JAN 08 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 2 9 2011
PERMIT CENTER
powered by aurora
Site Assessment
Customer: Rocco ',..ate.ro
Address: 12222 42nd Ave 5, Tuwiila, WA, 98168, USA
System size: 8iz3.5
Designer: Jeremy Hampsch
Date: Novernoe29tn, 2017
Notes:
Componen
Manufacturer Model Quantity
Itek Energy T295 -SE 30
SolarEdge Technologies Inc P300 30
SolarEdge Technologies Inc SE7600H-US
(none) Meter 2
(none) Disconnect
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
JAN 08 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 292011
PERMIT CENTER
pcw.mbed by aurora
f_ IRONRIDGE
Solar Is Not Always Sunny
Over their lifetime, solar panels experience countless
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
enough to buckle a panel frame.
XR Rails are the structural backbone preventing
these results. They resist uplift, protect
against buckling and safely and efficiently
transfer loads into the building structure.
Their superior spanning capability
requires fewer roof attachments,
reducing the number of roof
penetrations and the amount
of installation time.
XR Rail Family
Force -Stabilizing Curve
Sloped roofs generate both vertical and lateral
forces on mountin a rails which can cause them
to bend and twist
is specially ,•e
directions
feature ens res gr:}i. �?
weather ane a lone- .y` lif-time.
08 2013
JAN
Compatible with Flat & Pitched Roofs
XR Rails are
compatible with
FlashFoot and
" other pitched roof
attachments.
IronRidge offers
a range of tilt leg
options for flat
roof mounting
applications.
City of Tukwila
BUILDING DIVISION
Corrosion -Resistant Materials
All XR Rails are made of 6000 -series
aluminum alloy, then protected with an
anodized finish. Anodizing prevents surface
and structural corrosion, while also providing
a more attractive appearance.
RECEIVED
CITY OF TUKWILA
DEC 2 9 2011
PERMIT CENTER
XR Rail Family
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
XR10
XR10 is a sleek, low -profile mounting
rail, designed for regions with light or
no snow. It achieves 6 foot spans, while
remaining light and economical.
• 6' spanning capability
• Moderate load capability
• Clear & black anodized finish
• Internal splices available
Rail Selection
XR100
XR100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans up to 8 feet.
• 8' spanning capability
• Heavy load capability
• Clear & black anodized finish
• Internal splices available
XR1000
XR1000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans 12 feet or
more for commercial applications.
• 12' spanning capability
• Extreme load capability
• Clear anodized finish
• Internal splices available
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.
A
R
itihr IPONRIDGE
The Strongest Attachment in Solar
IronRidge FlashFoot2 raises the bar in solar roof
protection. The unique water seal design is both
elevated and encapsulated, delivering redundant layers
of protection against water intrusion. In addition, the
twist -on Cap perfectly aligns the rail attachment with the
lag bolt to maximize mechanical strength.
Twist -On Cap
FlashFoot2's unique Cap design encapsulates
the lag bolt and locks into place with a simple
twist. The Cap helps FlashFoot2 deliver
superior structural strength, by aligning
the rail and lag bolt in a concentric
load path.
FlashFoot2
Three -Tier Water Seal
FlashFoot2's seal architecture utilizes three
layers of protection. An elevated platform
diverts water away, while a stack of rugged
components raises the seal an entire inch.
The seal is then fully-encapuslated by the
Cap. FlashFoot2 is the first solar attachment
to pass the TAS -100 Wind -Driven Rain Test.
EIVED
F TUKWILA
EC 2 9 2011
RMIT CENTER
Single Socket Size
A custom -design tag bolt allows
you to install FlashFoot2 with
the same 7116" socket size
used on other Flush Mount
System components.
Water -Shedding Design
An elevated platform diverts water
away from the water seal.
Installation Features
A) Alignment Markers
Quickly align the flashing with chalk lines to find pilot holes.
Rounded Corners
Makes it easier to handle and insert under the roof shingles.
Reinforcement Ribs
Help to stiffen the flashing and previ
crinkling during installation.
REVIEWED .FOR
rOMPLIANCE WITH
NFPA 70 - NEC
JAN 0 8 2018
Benefits of 'I on;entric Loading
Traditional solar attachments have a
horizontal offset between the rail and lag
bolt, which introduces leverage on the lag
bolt and decreases uplift capacity.
FlashFoot2 is the only product to align the
rail and lag bolt. This concentric loading
design results in a stronger attachment for
the system.
0.1
1200
0 1000
.N 800
u
Q, 600
200
400
City of Tukwila
ION
1. 2
Rail -to -Lag Offset (in)
Testing & Certification
Structural Certification
Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7.
Water Seal Ratings
Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek.
Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12.
RECEIVED
CITY OF TUKWILA
DEC 2 9 2017
PERMIT CENTER
UL 2703
Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings.
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P320 / P370 / P400 / P405
USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS• UK-ISRAEL-TURKEY-SOUTHAFRICA- BULGARIA - INDIA www.solaredge.Us
SolarEdge Power Optimizer
Module Add -On for North America
P300/ P320 / P370 / P400 / P405
Rated input DC Powers 300 320 370 400 405 W
Absolute Maximum Input Voltage
Noe at lowest temperature)
MPPT Operating Range
Maximum Short Circuit Current (lsc)
Maximum DC Input Current
48
60
80
125
8-48 8-60 8-80 12.5 - 105
10
11
12.5 13.75
Maximum Efficiency
Weighted Efficiency
Overvoltage Category
' ''''"aikt)44'615ER-Atio-klilaCii-W84:b0.37'1142.-EAS-01\f'81. 8CTE- ifi.J.6#8##.10:0;tfOitt.:6040.1„ Ari
Maximum Output Current 15 Adc
Maximum Output Voltage80 85 Vdc
ba..14,0f,b,00111040.1keftiVti,413:EktigCOONCtfaii;k0Vf
Safety Output Voltage per Power
1
Optimizer
10.1
Vdc
Vdc
Adc
12.63
99.5
Adc
98.8
11
Vdc
STAP
EMC
Safety
RoHS
Al*iiMi
FCC Part15 Class 8 IEC61000-6-2 IEC61000-6-3
IEC62109-1 (class 11 safety), UL1741
Yes
Mfgri00000tati:OW
Maximum Allowed System Voltage
1000
Vdc
Compatible inverters
Dimensions (W x L x H)
Weight (including cables)
Input Connector
Output Wire Type / Connector
Output Wire Length
Operating Temperature Range
Protection Rating
Relative Humidity
All SolarEdge Single Phase and Three Phase inverters
128 x 152 x 27.5 /5 x 5.97 x 1.08
630/ 1.4
MC4 Compatible
128 x152 x35/
5 x 5.97 p137
750 / 1.7
MC4 /
Double Insulated; MC4 Compatible
0.95 / 3.0
Amphenol AH4
Double Insulated;
MC4 /
Amphenol AH4
MC4
RV1E EDFOR
PIA CSWITH
A OtilEC
mpatib e
Double Insulate
1.2 / 3.9
-40 - +85 / -40 - +185
1P68 / NEMA6P
0 - 100
; MC4 CorrAble
8 2018
m / ft
('‘ Rated STC power at the rx i'vlo4uie of up to +5% power tolerance allowed.
City of *Nita
BUILDING.DIV1410N.
EceivEc)
Minimum String Length
(Power Optimizers8 10 18>
Maximum String Length
(Power Optimizers)
Maximum Power per String
Parallel Strings of Different Lengths
or Orientations
25
5700 (6000 with
SE7600H-US)
25
0CITY F TUKWILA
5
5250 6000 12750
Yes
Pi For detailed string sizing information refer to: httpifiumnvisolaredge.com/sitesidefaultifiles)string_sizing_naipdli
tsi55 hat allowed to mix P405 with P300/P370/1,400/P600/P700 M one string.
dEC 2 9 2011
PEIMIT 'CENTER
di iS0i44
4
SolarEdge Single Phase Inverters
for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US /
SE7600H-US
USA-CANADA-GERMANY-UK-ITALY•THENETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-PRANCE-RF.LGIUh9-TURKEY-INDIA-BULGARIA-ROAAANIA-HUNGARY-SWEDEN- www.soIaredge.us
SOUTH AFRICA -POLAND -CZECH REPUBLIC
Single Phase Inverters for North America
SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/SE7600H-US
SES000H US:<:�:: SE3800H US : SE5000H-US. t .;SE6000H US J SE7600H U5:':
t1UTP1.)T
Rated AC Power Output
3000
3800
5000
6000
7600 VA
Max. AC Power Output
3000
3800
5000
6000
7600 VA
AC Output Voltage Min. -Nom. -Max. (183 - 208 - 229)
AC Output Voltage Min. -Nom -Max. (211 - 240 - 264)
✓
Vac
Vac
AC Frequency (Nomirai)
Maximum Continuous Output Current 208V
Maximum Continuous Output Current 240V
12.5
16
59.3-60-60.51�1
Hz
24
21
25
A
32
A
GFDI Threshold
1
A
Utility Monitoring, Islanding Protection,
Count Confi: urable Thresholds
Yes
-1NPtiT,,,,;z; s,z
Maximum DC Power
4650
5900
7750
9300
11800
Transformer -less, Ungrounded
Maximum Input Voltage
Yes
480
Nominal DC Input Voltage
380
Vdc
400
Vdc
Maximum Input Current 208V P4
Maximum Input Current 240V p'
Max. Input Short Circuit Current
Reverse -Polarity Protection
8.5
10.5
13.5
13.5 ; 16.5
20
Adc
Adc
45
Adc
Yes
Ground -Fault Isolation Detection
Maximum Inverter Efficiency
99
6001w Sensitivity
99.2
CEC Weighted Efficiency
99
Nighttime Power Consumption
AooDiti:104AV.# T.Mk S .. ' •,`
< 2.5
W
Supported Communication Interfaces
Revenue Grade Data, ANSI C12.20
Rapid Shutdown N 2014 and 2017 690 12
AN(}AFtD CME,134 fC •
Safety
Grid Connection Standards
Emissions
INSrTi4LLATION SPEC[FtCA€JONS
RS485, Ethernet, ZigBee (optional), Cellular (optional)
Optionalw
Automatic Rapid Shutdown upon AC Grid Disconnect
UL1741, UL1741 SA, UL16998, CSA C22.2, Canadian MCI according
IEEE1S47, Rule 21, Rule 14 (HI)
AC Output Conduit Size / AWG Range
DC Input Conduit Size / # of Strings / AWG Range
Dimensions with Safety Switch (HxWxD)
Weight with Safety Switch
Noise
Cooling
FCC Part 15 Class 8
VIE
7
FOR
.NEC
0.75-1" Conduit / 14-6 AWG
018
0.75-1" Conduit /1-2 strings / 14-6 AWG
17.7 x 14.6 x 6.8 / 450 x 370 x 174
22/10 1 25.1/11.4
< 25
Natural Convection
in/mm
Amiga
&DIVISION
26.2 / 1
Operating Temperature Range
Protection Rating
-13 to +140/ -25 to +600I (-407 / -40'C option)°
NEMA 3R (Inverter with Safety Switch)
erna fan
(User R CE$VED
replaceable
ceet Sri' KWILA
For other regional settings please contact SolarEdge support
r5 A higher current source may be used; the inverter will limit Its input wrrent to the values stated
p' Revenue grade inverter PfN: SF,000H-USOOONNQ
W Power de -rating from 50.0
5I-40 version P/N: SExxxaH-US000NNU4
DEC 2 9 2011
PERMIT CENTER
itek ENERGY SE SOLAR MODULES
Design & Engineering Data
Cell type
• 60 high -efficiency monocrystailine p -type cells
• 6x10 cell matrix
Solar Glass • Ultra -clear anti -reflective treatment
• Tempered, with low iron content
• Anti -glare prismatic subsurface texture
Backsheet
• Multi -layered
• Engineered adhesion for maximum weather protection
Frame
• High-strength corrosion -resistant anodized aluminum
• Compatible with standard racking, accomodafing both top-down
clomps and bottom -flange mounting
Cable
• 4z" iOC 12 AWG PV wire
Junction Box • 3 bypass diodes • 1000 VDC MC4 connectors
Grounding • Certified for Wiley Electronics WEEBTm grounding dips
• Eight standard grounding locations per module for
reduced ground wire length
UNGAR
UL Listing
UL 1703
Fire Rating
Type 2
P1D Free
96 + hours
Maximum Power - Rux(Wp)
Maximum Power Voltage - V+•. (V)
Maximum Power Current • 1w.(A)
Open Circuit Voltage - Voa(V)
Short Circuit Current - !sc(A)
Module Efficiency
280 285
32.3 32.4
8.6 8.7
39.2 39.3
9.3 9.4
16.70% 16.99%
EVA
Intertek
$E
290 295
32.6 32.8
8.8 8.9
39 5 39.7
9.5 9.6
17.29% 17.59%
Certified Made
In Washington
300
32.9
9.0
39.8
9.7
17.89%
NOTE: SPECIFICATIONS TO CHANGE WITHOUT NOTICE
[3.
27
[1.0
101.5 mm
203 mm
[8 in]
9.5 mm
itek=
ENERGY
Building Solar Powering The Future
CHANuCAL'I
Dimensions
11X)1 mm X 1675mm X 50mm
Weight
43 lbs
)M RATINGS
Operational Temperature
-40...+ 90°C
Maximum System Voltage 1000 VDC
Design Load (01 1703)
up to 113 lbs/ft2
Maximum Load (UL 1703) 551 kg/m2 (5400 Po)
Maximum Wind Load 113 lbs/f12
Max Series Fuse Rating
15A
Max Reverse Current
15A
ER 4 i
AT1N
Nominal Operating
Cell Temperature (NOCT)
45.01°C
Temperature Coefficient of P..
-0.39%1°C
Temperature Coefficient of Vac -0.29%/°C
Temperature Coefficient of 1 sc +0.04%/°C
Temperature Coefficient of VM.r -0.38%/°C
'Electrical characteristics may vary wit
indicated values at Sta
irradiance of 1,000W/
temperature at 25
5 m
9.5 mm
.._L,.
TyP
i
TYP
W 1.a/61nl is f.ivaint
/ NP NP
3.13 int _
\ + • • « •( • «
)mm
i4 in] _
-'
TIM
f inj
1
(_moi
f
III 1067mm .
�•
(39.4'
78 mm
7 in)
[42 in]
I
+
«
947 mm
127 mm
[5 In]-
-+
y.d
Junction Box
Frame Depth: 50 mrn (1.97in]
610
• (24
«
•
[37.48
mm
in],
inj/i
`
•t •
1219 mm
(48 in) 1675 mm
ih.5 94 ini
City ofTukwila
n]
RECEIVED
ITY OF TUKWILA
DEC 2 9 2011
PERMIT CENTER
V07.19.16
3886 Hammer Drive 1 Bellingham, Washington 98226 1360.647.9531 1 email:info@itekenergy_com • 1 www.itekenergy,com
itek ENERGY SE SOLAR MODULES
Design & Engineering Data
Cell type
• 60 high -efficiency monocrystalline p -type cells
• 6x10 cell matrix
Solar Glass • Ultra -clear anti -reflective treatment
• Tempered, with low iron content
• Anti -glare prismatic subsurface texture
Backsheet
• Multi -layered
• Engineered adhesion for maximum weather protection
Frame
• High-strength corrosion -resistant anodized aluminum
• Compatible with standard rocking, accomodating both top-down
damps and bottom -flange mounting
Cable • 42" 70C ? 2 AWG PV wire
Junction Box • 3 bypass diodes • 1000 VDC MC4 connectors
Grounding • Certified for Wiley Electronics WEEBTm grounding clips
• Eight standard grounding locations per module for
reduced ground wire length
IF(C'AT,I.
UL Listing
UL 1703
Fire Rating
Type 2
PID Free
96 + hours
Maximum Power-11,.2{Wp)
Maximum Power Voltage - V•vr (V)
Maximum Power Current - luny (A)
Open Circuit Voltage - Y (V)
Short Circuit Current - hc(A)
Module Efficiency
lntertek
Certified Made
In Washington
280 285 290 295 300
32.3 32.4 32.6 32.8 32.9
8.6 8.7 8.8 8.9 9.0
39.2 39.3 395 39J 39.8
9.3 9.4 9.5 9.6 9.7
16.70% 16.99% 17.29% 17.59% 17.89%
NOTE; SPECIFICATIONS SUB IECT TO CHANGE WITHOUT NOTICE
7
1
(3.
27
[1.0
101.5 mm
[4 in]
203 mm
(8 In)
9.5 mm
ENERGY
Building Sola! i Powering The Future
"tvtECH`
L';D;
Dimensions
1001 mm X 1675mm X 50mm
Weight
43 lbs
A;TIN
Operational Temperature
-40...+ 90°C
Maximum System Voltage 1000 VDC
Design Load {UL 1703)
up to 113 Ibs/ft2
Maximum Load (UL 1703)
Maximum Wind load
551 kg/m2 (5400 Pa)
(13 Ibs/ft'
Max Series Fuse Rating
(5A
Max Reverse Current
15A
=ATIN,
Nominal Operating 45.01°C
Cell Temperature (NOCT)
Temperature Coefficient of P... -0.39%/°C
Temperature Coefficient of Voc -0.29%/°C
Temperature Coefficient of 1 +0.04%/°C
Temperature Coefficient of VA., -0.38%/°C
'Electrical charocte
indicated values at
Irradiance of 1,000
temperature a1 25.0
5 m
9.5 mm
I
TYP
1
TYP
W l.ai3mi (0 (.tram)
/- TYP TYP
1.13 in)_
f/
1 mm
in)_
_.
1...014
TIM
sin)
I-�.i
t
•
1067mm
•
1001 1
[39 41
78 mm
r in]
_
[42 in]
)
f{I
t
'g,`L(ylll
i
o
947 mm
in]
127 mm
5 inj-
_•
-_e
Junction Box
Frame Depth: 50 mm 11.97in]
610
• (24
•
[37.18
mm
in)
. •
}.
1219 mm
(4B in] -1
1675 mm
165.94 inl
JAN 082016
GAY of .T�kWila
1
ILD NG PIVISIQ
in)
RECEIVED
CITY OF TUKWILA
DEC 2 9 2011
PERMIT CENTER
V07.19.16
3886 Hammer Drive 1 Bellingham, Washington 98226 1 360.647.9531 1 emaii:info@itekenergy.com 1 www.itekenergy.com
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL17-1058 DATE: 12/29/17
PROJECT NAME: MATERO RESIDENCE
SITE ADDRESS: 12222 42 AVE S
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
NC l—Si
Building Division 111
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
n
1
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 01/02/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 01/30/18
Approved
Corrections Required
❑ Approved with Conditions
❑ Denied
(corrections entered in Reviews) (ie: Zoning Issues)
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials:
12/18/2013
Offset Solar LLC
Home Espanol Contact
Search L&I
Page 1 of 2
SEARCH
A -Z Index Help My L&I
Safety & Health Claims & Insurance Workplace Rights Trades & Licensing
CWashington State Department of
4610 Labor & industries
Offset Solar LLC
Owner or tradesperson
Principals
Billetz, Konrad C, PARTNER/MEMBER
Hampsch, Jeremy D, PARTNER/MEMBER
Washington Reg Agent LLC, AGENT
Doing business as
Offset Solar LLC
WA UBI No.
604 170 735
933 Louise Ste 101E
CHARLOTTE, NC 28204
877-633-7385
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
OFFSESL833PE
Effective — expiration
10/16/2017-10/16/2019
Designated administrator
Averett, Nicholas Bige
Active.
Meets current requirements.
License type License no.
Master Electrician AVERENB835JG
Bond
Western Surety Co
Bond account no.
63363781
Received by L&I
10/16/2017
Savings
No savings accounts during the previous 6 year period.
License Violations
No license violations during the previous 6 year period.
$4,000.00
Effective date
09/26/2017
Expiration date
Until Canceled
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Recently opened account.
651,785-00 No premiums due yet.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60417073 5&LIC=OFFSESL833PE&SAW= 1/11/2018
Offset Solar LLC
Doing business as ( *'
OFFSET SOLAR
Estimated workers reported
N/A
L&I account contact
T5 1 JAVIER PAREDES (360)902-4639 - Email: PAJB235@Ini.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
Page 2 of 2
n Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60417073 5&LIC=OFFSESL833PE&SAW= 1/11/2018